Update v2_nextpart.idf

Browse files
Files changed (1) hide show
  1. v2_nextpart.idf +7 -36
v2_nextpart.idf CHANGED
@@ -220,9 +220,9 @@ Building,
220
  ZoneControl:Thermostat,
221
  Thermal Zone 1 Thermostat, !- Name
222
  Thermal Zone 1, !- Zone or ZoneList Name
223
- Thermal Zone 1 Thermostat Schedule, !- Control Type Schedule Name
224
  ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
225
- Thermostat Setpoint Dual Setpoint 1, !- Control 1 Name
226
  , !- Control 2 Object Type
227
  , !- Control 2 Name
228
  , !- Control 3 Object Type
@@ -232,21 +232,21 @@ ZoneControl:Thermostat,
232
  0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
233
 
234
  Schedule:Compact,
235
- Thermal Zone 1 Thermostat Schedule, !- Name
236
- Thermal Zone 1 Thermostat Schedule Type Limits, !- Schedule Type Limits Name
237
  Through: 12/31, !- Field 1
238
  For: AllDays, !- Field 2
239
  Until: 24:00, !- Field 3
240
  4; !- Field 4
241
 
242
  ScheduleTypeLimits,
243
- Thermal Zone 1 Thermostat Schedule Type Limits, !- Name
244
  0, !- Lower Limit Value {BasedOnField A3}
245
  4, !- Upper Limit Value {BasedOnField A3}
246
  DISCRETE; !- Numeric Type
247
 
248
  ThermostatSetpoint:DualSetpoint,
249
- Thermostat Setpoint Dual Setpoint 1, !- Name
250
  HtgSetp, !- Heating Setpoint Temperature Schedule Name
251
  ClgSetp; !- Cooling Setpoint Temperature Schedule Name
252
 
@@ -343,34 +343,6 @@ Schedule:Day:Interval,
343
  No, !- Interpolate to Timestep
344
  24:00, !- Time 1 {hh:mm}
345
  26.7; !- Value Until Time 1
346
- !
347
- ! HVACTemplate:Zone:IdealLoadsAirSystem,
348
- ! Thermal Zone 1, !- Zone Name
349
- ! , !- Template Thermostat Name
350
- ! , !- System Availability Schedule Name
351
- ! , !- Maximum Heating Supply Air Temperature {C}
352
- ! , !- Minimum Cooling Supply Air Temperature {C}
353
- ! , !- Maximum Heating Supply Air Humidity Ratio {kgWater/kgDryAir}
354
- ! , !- Minimum Cooling Supply Air Humidity Ratio {kgWater/kgDryAir}
355
- ! , !- Heating Limit
356
- ! , !- Maximum Heating Air Flow Rate {m3/s}
357
- ! , !- Maximum Sensible Heating Capacity {W}
358
- ! , !- Cooling Limit
359
- ! , !- Maximum Cooling Air Flow Rate {m3/s}
360
- ! , !- Maximum Total Cooling Capacity {W}
361
- ! , !- Heating Availability Schedule Name
362
- ! , !- Cooling Availability Schedule Name
363
- ! , !- Dehumidification Control Type
364
- ! , !- Cooling Sensible Heat Ratio {dimensionless}
365
- ! , !- Dehumidification Setpoint {percent}
366
- ! , !- Humidification Control Type
367
- ! , !- Humidification Setpoint {percent}
368
- ! , !- Outdoor Air Method
369
- ! , !- Outdoor Air Flow Rate per Person {m3/s}
370
- ! , !- Outdoor Air Flow Rate per Zone Floor Area {m3/s-m2}
371
- ! , !- Outdoor Air Flow Rate per Zone {m3/s}
372
- ! , !- Design Specification Outdoor Air Object Name
373
- ! ; !- Demand Controlled Ventilation Type
374
 
375
  Sizing:Zone,
376
  Thermal Zone 1, !- Zone or ZoneList Name
@@ -565,9 +537,8 @@ Material,
565
  0.85, !- Solar Absorptance
566
  0.85; !- Visible Absorptance
567
 
568
-
569
-
570
  ! roof insu
 
571
  Material,
572
  Roof Insulation [3.5], !- Name
573
  MediumRough, !- Roughness
 
220
  ZoneControl:Thermostat,
221
  Thermal Zone 1 Thermostat, !- Name
222
  Thermal Zone 1, !- Zone or ZoneList Name
223
+ Thermostat Schedule, !- Control Type Schedule Name
224
  ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
225
+ Thermostat Setpoint Dual Setpoint, !- Control 1 Name
226
  , !- Control 2 Object Type
227
  , !- Control 2 Name
228
  , !- Control 3 Object Type
 
232
  0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
233
 
234
  Schedule:Compact,
235
+ Thermostat Schedule, !- Name
236
+ Thermostat Schedule Type Limits, !- Schedule Type Limits Name
237
  Through: 12/31, !- Field 1
238
  For: AllDays, !- Field 2
239
  Until: 24:00, !- Field 3
240
  4; !- Field 4
241
 
242
  ScheduleTypeLimits,
243
+ Thermostat Schedule Type Limits, !- Name
244
  0, !- Lower Limit Value {BasedOnField A3}
245
  4, !- Upper Limit Value {BasedOnField A3}
246
  DISCRETE; !- Numeric Type
247
 
248
  ThermostatSetpoint:DualSetpoint,
249
+ Thermostat Setpoint Dual Setpoint, !- Name
250
  HtgSetp, !- Heating Setpoint Temperature Schedule Name
251
  ClgSetp; !- Cooling Setpoint Temperature Schedule Name
252
 
 
343
  No, !- Interpolate to Timestep
344
  24:00, !- Time 1 {hh:mm}
345
  26.7; !- Value Until Time 1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
346
 
347
  Sizing:Zone,
348
  Thermal Zone 1, !- Zone or ZoneList Name
 
537
  0.85, !- Solar Absorptance
538
  0.85; !- Visible Absorptance
539
 
 
 
540
  ! roof insu
541
+
542
  Material,
543
  Roof Insulation [3.5], !- Name
544
  MediumRough, !- Roughness