diff --git "a/validated building models/LLM-BEM-Engineer_Generated_Building_Model_2_4.idf" "b/validated building models/LLM-BEM-Engineer_Generated_Building_Model_2_4.idf" new file mode 100644--- /dev/null +++ "b/validated building models/LLM-BEM-Engineer_Generated_Building_Model_2_4.idf" @@ -0,0 +1,7244 @@ +! ==================================== Execution 1 Started ==================================== + + +BuildingSurface:Detailed,Floor 1 0,Floor,ExtSlabCarpet,Thermal Zone 1,,Ground,,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 0,Floor,ExtSlabCarpet,Thermal Zone 2,,Ground,,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Ceiling 1 0,Ceiling,Interior Ceiling,Thermal Zone 1,,Surface,Floor 1 1,NoSun,NoWind,,,492.50,0,6.04,492.50,91.99,6.04,583.00,91.99,6.04,187.65,91.99,6.04,0,91.99,6.04,0,0,6.04; +BuildingSurface:Detailed,Ceiling 2 0,Ceiling,Interior Ceiling,Thermal Zone 2,,Surface,Floor 2 1,NoSun,NoWind,,,583.00,91.99,6.04,583.00,306.99,6.04,187.65,306.99,6.04,187.65,91.99,6.04; + +BuildingSurface:Detailed,Face 6 0,Wall,Interior Wall,Thermal Zone 1,,Surface,Face 21 0,NoSun,NoWind,,,187.65,91.99,6.04,583.00,91.99,6.04,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 0,Wall,Interior Wall,Thermal Zone 2,,Surface,Face 6 0,NoSun,NoWind,,,583.00,91.99,6.04,583.00,91.99,0,187.65,91.99,0,187.65,91.99,6.04; + +BuildingSurface:Detailed,Face 11 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,492.50,0,6.04,0,0,6.04,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,0,0,6.04,0,91.99,6.04,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,0,91.99,6.04,187.65,91.99,6.04,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,6.04,492.50,91.99,6.04,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,6.04,492.50,0,6.04,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,6.04,187.65,306.99,6.04,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,6.04,583.00,306.99,6.04,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,6.04,583.00,91.99,6.04,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 0,Window,Ext Window,Face 9 0,,,,,,492.50,0.01,4.14,492.50,0.01,1.90,492.50,91.98,1.90,492.50,91.98,4.14; +FenestrationSurface:Detailed,Face 20 0,Window,Ext Window,Face 19 0,,,,,,583.00,92.00,4.14,583.00,92.00,1.90,583.00,306.98,1.90,583.00,306.98,4.14; + +! nwin +FenestrationSurface:Detailed,Face 5 0,Window,Ext Window,Face 4 0,,,,,,187.64,91.99,4.80,187.64,91.99,1.24,0.01,91.99,1.24,0.01,91.99,4.80; +FenestrationSurface:Detailed,Face 8 0,Window,Ext Window,Face 7 0,,,,,,492.49,91.99,4.80,492.49,91.99,1.24,583.01,91.99,1.24,583.01,91.99,4.80; +FenestrationSurface:Detailed,Face 18 0,Window,Ext Window,Face 17 0,,,,,,582.99,306.99,4.80,582.99,306.99,1.24,187.66,306.99,1.24,187.66,306.99,4.80; + +! swin +FenestrationSurface:Detailed,Face 12 0,Window,Ext Window,Face 11 0,,,,,,0.01,0,4.92,0.01,0,1.12,492.49,0,1.12,492.49,0,4.92; + +! wwin +FenestrationSurface:Detailed,Face 3 0,Window,Ext Window,Face 2 0,,,,,,0,91.98,4.41,0,91.98,1.63,0,0.01,1.63,0,0.01,4.41; +FenestrationSurface:Detailed,Face 16 0,Window,Ext Window,Face 15 0,,,,,,187.65,306.98,4.41,187.65,306.98,1.63,187.65,92.00,1.63,187.65,92.00,4.41; + +Zone,Thermal Zone 1,135.00,0,0,0.00,,1,,,,,,Yes; +Zone,Thermal Zone 2,135.00,0,0,0.00,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 1,Floor,Interior Floor,Thermal Zone 3,,Surface,Ceiling 1 0,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 1,Floor,Interior Floor,Thermal Zone 4,,Surface,Ceiling 2 0,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Ceiling 1 1,Ceiling,Interior Ceiling,Thermal Zone 3,,Surface,Floor 1 2,NoSun,NoWind,,,492.50,0,12.39,492.50,91.99,12.39,583.00,91.99,12.39,187.65,91.99,12.39,0,91.99,12.39,0,0,12.39; +BuildingSurface:Detailed,Ceiling 2 1,Ceiling,Interior Ceiling,Thermal Zone 4,,Surface,Floor 2 2,NoSun,NoWind,,,583.00,91.99,12.39,583.00,306.99,12.39,187.65,306.99,12.39,187.65,91.99,12.39; + +BuildingSurface:Detailed,Face 6 1,Wall,Interior Wall,Thermal Zone 3,,Surface,Face 21 1,NoSun,NoWind,,,187.65,91.99,12.39,583.00,91.99,12.39,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 1,Wall,Interior Wall,Thermal Zone 4,,Surface,Face 6 1,NoSun,NoWind,,,583.00,91.99,12.39,583.00,91.99,0,187.65,91.99,0,187.65,91.99,12.39; + +BuildingSurface:Detailed,Face 11 1,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,492.50,0,12.39,0,0,12.39,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 1,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,0,0,12.39,0,91.99,12.39,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 1,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,0,91.99,12.39,187.65,91.99,12.39,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 1,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,12.39,492.50,91.99,12.39,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 1,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,12.39,492.50,0,12.39,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,12.39,187.65,306.99,12.39,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,12.39,583.00,306.99,12.39,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,12.39,583.00,91.99,12.39,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 1,Window,Ext Window,Face 9 1,,,,,,492.50,0.01,8.49,492.50,0.01,3.90,492.50,91.98,3.90,492.50,91.98,8.49; +FenestrationSurface:Detailed,Face 20 1,Window,Ext Window,Face 19 1,,,,,,583.00,92.00,8.49,583.00,92.00,3.90,583.00,306.98,3.90,583.00,306.98,8.49; + +! nwin +FenestrationSurface:Detailed,Face 5 1,Window,Ext Window,Face 4 1,,,,,,187.64,91.99,9.85,187.64,91.99,2.54,0.01,91.99,2.54,0.01,91.99,9.85; +FenestrationSurface:Detailed,Face 8 1,Window,Ext Window,Face 7 1,,,,,,492.49,91.99,9.85,492.49,91.99,2.54,583.01,91.99,2.54,583.01,91.99,9.85; +FenestrationSurface:Detailed,Face 18 1,Window,Ext Window,Face 17 1,,,,,,582.99,306.99,9.85,582.99,306.99,2.54,187.66,306.99,2.54,187.66,306.99,9.85; + +! swin +FenestrationSurface:Detailed,Face 12 1,Window,Ext Window,Face 11 1,,,,,,0.01,0,10.10,0.01,0,2.29,492.49,0,2.29,492.49,0,10.10; + +! wwin +FenestrationSurface:Detailed,Face 3 1,Window,Ext Window,Face 2 1,,,,,,0,91.98,9.04,0,91.98,3.35,0,0.01,3.35,0,0.01,9.04; +FenestrationSurface:Detailed,Face 16 1,Window,Ext Window,Face 15 1,,,,,,187.65,306.98,9.04,187.65,306.98,3.35,187.65,92.00,3.35,187.65,92.00,9.04; + +Zone,Thermal Zone 3,135.00,0,0,6.04,,1,,,,,,Yes; +Zone,Thermal Zone 4,135.00,0,0,6.04,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 2,Floor,Interior Floor,Thermal Zone 5,,Surface,Ceiling 1 1,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 2,Floor,Interior Floor,Thermal Zone 6,,Surface,Ceiling 2 1,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Ceiling 1 2,Ceiling,Interior Ceiling,Thermal Zone 5,,Surface,Floor 1 3,NoSun,NoWind,,,492.50,0,14.71,492.50,91.99,14.71,583.00,91.99,14.71,187.65,91.99,14.71,0,91.99,14.71,0,0,14.71; +BuildingSurface:Detailed,Ceiling 2 2,Ceiling,Interior Ceiling,Thermal Zone 6,,Surface,Floor 2 3,NoSun,NoWind,,,583.00,91.99,14.71,583.00,306.99,14.71,187.65,306.99,14.71,187.65,91.99,14.71; + +BuildingSurface:Detailed,Face 6 2,Wall,Interior Wall,Thermal Zone 5,,Surface,Face 21 2,NoSun,NoWind,,,187.65,91.99,14.71,583.00,91.99,14.71,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 2,Wall,Interior Wall,Thermal Zone 6,,Surface,Face 6 2,NoSun,NoWind,,,583.00,91.99,14.71,583.00,91.99,0,187.65,91.99,0,187.65,91.99,14.71; + +BuildingSurface:Detailed,Face 11 2,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,492.50,0,14.71,0,0,14.71,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 2,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,0,0,14.71,0,91.99,14.71,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 2,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,0,91.99,14.71,187.65,91.99,14.71,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 2,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,14.71,492.50,91.99,14.71,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 2,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,14.71,492.50,0,14.71,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 2,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,14.71,187.65,306.99,14.71,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 2,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,14.71,583.00,306.99,14.71,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 2,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,14.71,583.00,91.99,14.71,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 2,Window,Ext Window,Face 9 2,,,,,,492.50,0.01,10.08,492.50,0.01,4.63,492.50,91.98,4.63,492.50,91.98,10.08; +FenestrationSurface:Detailed,Face 20 2,Window,Ext Window,Face 19 2,,,,,,583.00,92.00,10.08,583.00,92.00,4.63,583.00,306.98,4.63,583.00,306.98,10.08; + +! nwin +FenestrationSurface:Detailed,Face 5 2,Window,Ext Window,Face 4 2,,,,,,187.64,91.99,11.69,187.64,91.99,3.02,0.01,91.99,3.02,0.01,91.99,11.69; +FenestrationSurface:Detailed,Face 8 2,Window,Ext Window,Face 7 2,,,,,,492.49,91.99,11.69,492.49,91.99,3.02,583.01,91.99,3.02,583.01,91.99,11.69; +FenestrationSurface:Detailed,Face 18 2,Window,Ext Window,Face 17 2,,,,,,582.99,306.99,11.69,582.99,306.99,3.02,187.66,306.99,3.02,187.66,306.99,11.69; + +! swin +FenestrationSurface:Detailed,Face 12 2,Window,Ext Window,Face 11 2,,,,,,0.01,0,11.99,0.01,0,2.72,492.49,0,2.72,492.49,0,11.99; + +! wwin +FenestrationSurface:Detailed,Face 3 2,Window,Ext Window,Face 2 2,,,,,,0,91.98,10.74,0,91.98,3.97,0,0.01,3.97,0,0.01,10.74; +FenestrationSurface:Detailed,Face 16 2,Window,Ext Window,Face 15 2,,,,,,187.65,306.98,10.74,187.65,306.98,3.97,187.65,92.00,3.97,187.65,92.00,10.74; + +Zone,Thermal Zone 5,135.00,0,0,18.43,,1,,,,,,Yes; +Zone,Thermal Zone 6,135.00,0,0,18.43,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 3,Floor,Interior Floor,Thermal Zone 7,,Surface,Ceiling 1 2,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 3,Floor,Interior Floor,Thermal Zone 8,,Surface,Ceiling 2 2,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Ceiling 1 3,Ceiling,Interior Ceiling,Thermal Zone 7,,Surface,Floor 1 4,NoSun,NoWind,,,492.50,0,5.69,492.50,91.99,5.69,583.00,91.99,5.69,187.65,91.99,5.69,0,91.99,5.69,0,0,5.69; +BuildingSurface:Detailed,Ceiling 2 3,Ceiling,Interior Ceiling,Thermal Zone 8,,Surface,Floor 2 4,NoSun,NoWind,,,583.00,91.99,5.69,583.00,306.99,5.69,187.65,306.99,5.69,187.65,91.99,5.69; + +BuildingSurface:Detailed,Face 6 3,Wall,Interior Wall,Thermal Zone 7,,Surface,Face 21 3,NoSun,NoWind,,,187.65,91.99,5.69,583.00,91.99,5.69,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 3,Wall,Interior Wall,Thermal Zone 8,,Surface,Face 6 3,NoSun,NoWind,,,583.00,91.99,5.69,583.00,91.99,0,187.65,91.99,0,187.65,91.99,5.69; + +BuildingSurface:Detailed,Face 11 3,Wall,Ext Wall,Thermal Zone 7,,Outdoors,,SunExposed,WindExposed,,,492.50,0,5.69,0,0,5.69,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 3,Wall,Ext Wall,Thermal Zone 7,,Outdoors,,SunExposed,WindExposed,,,0,0,5.69,0,91.99,5.69,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 3,Wall,Ext Wall,Thermal Zone 7,,Outdoors,,SunExposed,WindExposed,,,0,91.99,5.69,187.65,91.99,5.69,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 3,Wall,Ext Wall,Thermal Zone 7,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,5.69,492.50,91.99,5.69,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 3,Wall,Ext Wall,Thermal Zone 7,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,5.69,492.50,0,5.69,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 3,Wall,Ext Wall,Thermal Zone 8,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,5.69,187.65,306.99,5.69,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 3,Wall,Ext Wall,Thermal Zone 8,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,5.69,583.00,306.99,5.69,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 3,Wall,Ext Wall,Thermal Zone 8,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,5.69,583.00,91.99,5.69,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 3,Window,Ext Window,Face 9 3,,,,,,492.50,0.01,3.90,492.50,0.01,1.79,492.50,91.98,1.79,492.50,91.98,3.90; +FenestrationSurface:Detailed,Face 20 3,Window,Ext Window,Face 19 3,,,,,,583.00,92.00,3.90,583.00,92.00,1.79,583.00,306.98,1.79,583.00,306.98,3.90; + +! nwin +FenestrationSurface:Detailed,Face 5 3,Window,Ext Window,Face 4 3,,,,,,187.64,91.99,4.52,187.64,91.99,1.17,0.01,91.99,1.17,0.01,91.99,4.52; +FenestrationSurface:Detailed,Face 8 3,Window,Ext Window,Face 7 3,,,,,,492.49,91.99,4.52,492.49,91.99,1.17,583.01,91.99,1.17,583.01,91.99,4.52; +FenestrationSurface:Detailed,Face 18 3,Window,Ext Window,Face 17 3,,,,,,582.99,306.99,4.52,582.99,306.99,1.17,187.66,306.99,1.17,187.66,306.99,4.52; + +! swin +FenestrationSurface:Detailed,Face 12 3,Window,Ext Window,Face 11 3,,,,,,0.01,0,4.64,0.01,0,1.05,492.49,0,1.05,492.49,0,4.64; + +! wwin +FenestrationSurface:Detailed,Face 3 3,Window,Ext Window,Face 2 3,,,,,,0,91.98,4.15,0,91.98,1.54,0,0.01,1.54,0,0.01,4.15; +FenestrationSurface:Detailed,Face 16 3,Window,Ext Window,Face 15 3,,,,,,187.65,306.98,4.15,187.65,306.98,1.54,187.65,92.00,1.54,187.65,92.00,4.15; + +Zone,Thermal Zone 7,135.00,0,0,33.14,,1,,,,,,Yes; +Zone,Thermal Zone 8,135.00,0,0,33.14,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 4,Floor,Interior Floor,Thermal Zone 9,,Surface,Ceiling 1 3,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 4,Floor,Interior Floor,Thermal Zone 10,,Surface,Ceiling 2 3,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Ceiling 1 4,Ceiling,Interior Ceiling,Thermal Zone 9,,Surface,Floor 1 5,NoSun,NoWind,,,492.50,0,8.07,492.50,91.99,8.07,583.00,91.99,8.07,187.65,91.99,8.07,0,91.99,8.07,0,0,8.07; +BuildingSurface:Detailed,Ceiling 2 4,Ceiling,Interior Ceiling,Thermal Zone 10,,Surface,Floor 2 5,NoSun,NoWind,,,583.00,91.99,8.07,583.00,306.99,8.07,187.65,306.99,8.07,187.65,91.99,8.07; + +BuildingSurface:Detailed,Face 6 4,Wall,Interior Wall,Thermal Zone 9,,Surface,Face 21 4,NoSun,NoWind,,,187.65,91.99,8.07,583.00,91.99,8.07,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 4,Wall,Interior Wall,Thermal Zone 10,,Surface,Face 6 4,NoSun,NoWind,,,583.00,91.99,8.07,583.00,91.99,0,187.65,91.99,0,187.65,91.99,8.07; + +BuildingSurface:Detailed,Face 11 4,Wall,Ext Wall,Thermal Zone 9,,Outdoors,,SunExposed,WindExposed,,,492.50,0,8.07,0,0,8.07,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 4,Wall,Ext Wall,Thermal Zone 9,,Outdoors,,SunExposed,WindExposed,,,0,0,8.07,0,91.99,8.07,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 4,Wall,Ext Wall,Thermal Zone 9,,Outdoors,,SunExposed,WindExposed,,,0,91.99,8.07,187.65,91.99,8.07,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 4,Wall,Ext Wall,Thermal Zone 9,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,8.07,492.50,91.99,8.07,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 4,Wall,Ext Wall,Thermal Zone 9,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,8.07,492.50,0,8.07,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 4,Wall,Ext Wall,Thermal Zone 10,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,8.07,187.65,306.99,8.07,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 4,Wall,Ext Wall,Thermal Zone 10,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,8.07,583.00,306.99,8.07,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 4,Wall,Ext Wall,Thermal Zone 10,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,8.07,583.00,91.99,8.07,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 4,Window,Ext Window,Face 9 4,,,,,,492.50,0.01,5.53,492.50,0.01,2.54,492.50,91.98,2.54,492.50,91.98,5.53; +FenestrationSurface:Detailed,Face 20 4,Window,Ext Window,Face 19 4,,,,,,583.00,92.00,5.53,583.00,92.00,2.54,583.00,306.98,2.54,583.00,306.98,5.53; + +! nwin +FenestrationSurface:Detailed,Face 5 4,Window,Ext Window,Face 4 4,,,,,,187.64,91.99,6.42,187.64,91.99,1.65,0.01,91.99,1.65,0.01,91.99,6.42; +FenestrationSurface:Detailed,Face 8 4,Window,Ext Window,Face 7 4,,,,,,492.49,91.99,6.42,492.49,91.99,1.65,583.01,91.99,1.65,583.01,91.99,6.42; +FenestrationSurface:Detailed,Face 18 4,Window,Ext Window,Face 17 4,,,,,,582.99,306.99,6.42,582.99,306.99,1.65,187.66,306.99,1.65,187.66,306.99,6.42; + +! swin +FenestrationSurface:Detailed,Face 12 4,Window,Ext Window,Face 11 4,,,,,,0.01,0,6.58,0.01,0,1.49,492.49,0,1.49,492.49,0,6.58; + +! wwin +FenestrationSurface:Detailed,Face 3 4,Window,Ext Window,Face 2 4,,,,,,0,91.98,5.89,0,91.98,2.18,0,0.01,2.18,0,0.01,5.89; +FenestrationSurface:Detailed,Face 16 4,Window,Ext Window,Face 15 4,,,,,,187.65,306.98,5.89,187.65,306.98,2.18,187.65,92.00,2.18,187.65,92.00,5.89; + +Zone,Thermal Zone 9,135.00,0,0,38.83,,1,,,,,,Yes; +Zone,Thermal Zone 10,135.00,0,0,38.83,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 5,Floor,Interior Floor,Thermal Zone 11,,Surface,Ceiling 1 4,NoSun,NoWind,,,0,0,0,0,91.99,0,187.65,91.99,0,583.00,91.99,0,492.50,91.99,0,492.50,0,0; +BuildingSurface:Detailed,Floor 2 5,Floor,Interior Floor,Thermal Zone 12,,Surface,Ceiling 2 4,NoSun,NoWind,,,187.65,91.99,0,187.65,306.99,0,583.00,306.99,0,583.00,91.99,0; + + +BuildingSurface:Detailed,Roof 1 5,Roof,Ext Roof,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,492.50,0,10.62,492.50,91.99,10.62,583.00,91.99,10.62,187.65,91.99,10.62,0,91.99,10.62,0,0,10.62; +BuildingSurface:Detailed,Roof 2 5,Roof,Ext Roof,Thermal Zone 12,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,10.62,583.00,306.99,10.62,187.65,306.99,10.62,187.65,91.99,10.62; + +BuildingSurface:Detailed,Face 6 5,Wall,Interior Wall,Thermal Zone 11,,Surface,Face 21 5,NoSun,NoWind,,,187.65,91.99,10.62,583.00,91.99,10.62,583.00,91.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 21 5,Wall,Interior Wall,Thermal Zone 12,,Surface,Face 6 5,NoSun,NoWind,,,583.00,91.99,10.62,583.00,91.99,0,187.65,91.99,0,187.65,91.99,10.62; + +BuildingSurface:Detailed,Face 11 5,Wall,Ext Wall,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,492.50,0,10.62,0,0,10.62,0,0,0,492.50,0,0; +BuildingSurface:Detailed,Face 2 5,Wall,Ext Wall,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,0,0,10.62,0,91.99,10.62,0,91.99,0,0,0,0; +BuildingSurface:Detailed,Face 4 5,Wall,Ext Wall,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,0,91.99,10.62,187.65,91.99,10.62,187.65,91.99,0,0,91.99,0; +BuildingSurface:Detailed,Face 7 5,Wall,Ext Wall,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,583.00,91.99,10.62,492.50,91.99,10.62,492.50,91.99,0,583.00,91.99,0; +BuildingSurface:Detailed,Face 9 5,Wall,Ext Wall,Thermal Zone 11,,Outdoors,,SunExposed,WindExposed,,,492.50,91.99,10.62,492.50,0,10.62,492.50,0,0,492.50,91.99,0; +BuildingSurface:Detailed,Face 15 5,Wall,Ext Wall,Thermal Zone 12,,Outdoors,,SunExposed,WindExposed,,,187.65,91.99,10.62,187.65,306.99,10.62,187.65,306.99,0,187.65,91.99,0; +BuildingSurface:Detailed,Face 17 5,Wall,Ext Wall,Thermal Zone 12,,Outdoors,,SunExposed,WindExposed,,,187.65,306.99,10.62,583.00,306.99,10.62,583.00,306.99,0,187.65,306.99,0; +BuildingSurface:Detailed,Face 19 5,Wall,Ext Wall,Thermal Zone 12,,Outdoors,,SunExposed,WindExposed,,,583.00,306.99,10.62,583.00,91.99,10.62,583.00,91.99,0,583.00,306.99,0; + +! ewin +FenestrationSurface:Detailed,Face 10 5,Window,Ext Window,Face 9 5,,,,,,492.50,0.01,7.27,492.50,0.01,3.35,492.50,91.98,3.35,492.50,91.98,7.27; +FenestrationSurface:Detailed,Face 20 5,Window,Ext Window,Face 19 5,,,,,,583.00,92.00,7.27,583.00,92.00,3.35,583.00,306.98,3.35,583.00,306.98,7.27; + +! nwin +FenestrationSurface:Detailed,Face 5 5,Window,Ext Window,Face 4 5,,,,,,187.64,91.99,8.44,187.64,91.99,2.18,0.01,91.99,2.18,0.01,91.99,8.44; +FenestrationSurface:Detailed,Face 8 5,Window,Ext Window,Face 7 5,,,,,,492.49,91.99,8.44,492.49,91.99,2.18,583.01,91.99,2.18,583.01,91.99,8.44; +FenestrationSurface:Detailed,Face 18 5,Window,Ext Window,Face 17 5,,,,,,582.99,306.99,8.44,582.99,306.99,2.18,187.66,306.99,2.18,187.66,306.99,8.44; + +! swin +FenestrationSurface:Detailed,Face 12 5,Window,Ext Window,Face 11 5,,,,,,0.01,0,8.66,0.01,0,1.96,492.49,0,1.96,492.49,0,8.66; + +! wwin +FenestrationSurface:Detailed,Face 3 5,Window,Ext Window,Face 2 5,,,,,,0,91.98,7.75,0,91.98,2.87,0,0.01,2.87,0,0.01,7.75; +FenestrationSurface:Detailed,Face 16 5,Window,Ext Window,Face 15 5,,,,,,187.65,306.98,7.75,187.65,306.98,2.87,187.65,92.00,2.87,187.65,92.00,7.75; + +Zone,Thermal Zone 11,135.00,0,0,46.90,,1,,,,,,Yes; +Zone,Thermal Zone 12,135.00,0,0,46.90,,1,,,,,,Yes; + +! ==================================== Execution 1 Successful ==================================== +! ==================================== Execution 2 Started ==================================== + +! wall material +Material, + wall concrete, !- Name + MediumRough, !- Roughness + 0.398, !- Thickness m + 0.5, !- Conductivity W/m-K + 2242.99999999999, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +Material, + wall gypsum, !- Name + MediumSmooth, !- Roughness + 0.398, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +Material, + wall wood, !- Name + MediumSmooth, !- Roughness + 0.398, !- Thickness m + 0.15, !- Conductivity W/m-K + 608, !- Density kg/m3 + 1630, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + wall metal, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 45.2800000000001, !- Conductivity W/m-K + 7823.99999999999, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + wall rammed earth, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 1.5, !- Conductivity W/m-K + 1540.0, !- Density kg/m3 + 1260, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + wall brick, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 0.7, !- Conductivity W/m-K + 1800.0, !- Density kg/m3 + 829, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +! roof material +Material, + roof concrete, !- Name + MediumRough, !- Roughness + 0.401, !- Thickness m + 0.5, !- Conductivity W/m-K + 2242.99999999999, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +Material, + roof gypsum, !- Name + MediumSmooth, !- Roughness + 0.401, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +Material, + roof wood, !- Name + MediumSmooth, !- Roughness + 0.401, !- Thickness m + 0.15, !- Conductivity W/m-K + 608, !- Density kg/m3 + 1630, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + roof metal, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 45.2800000000001, !- Conductivity W/m-K + 7823.99999999999, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + roof rammed earth, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 1.5, !- Conductivity W/m-K + 1540.0, !- Density kg/m3 + 1260, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + roof brick, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 0.7, !- Conductivity W/m-K + 1800.0, !- Density kg/m3 + 829, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + + + +! wall insu + + + + + + + +! extro wall materials +Material, + Wall Insulation [19], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [20], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [22], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [23], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [24], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [27], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [28], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [29], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [30], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [32], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [33], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [34], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [38], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [39], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [41], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +! [43]=[44] +Material, + Wall Insulation [43], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + + +! extro roof materials +Material, + Roof Insulation [19], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [20], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [22], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [23], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [24], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [27], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [28], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [29], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [30], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [32], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [33], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [34], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [38], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [39], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [41], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +! [43]=[44] +Material, + Roof Insulation [43], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + + + + + +! real materials +Material, + Wall Insulation [18], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [21], !- Name + MediumRough, !- Roughness + 0.2105, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [25], !- Name + MediumRough, !- Roughness + 0.263, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [26], !- Name + MediumRough, !- Roughness + 0.2941, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [31], !- Name + MediumRough, !- Roughness + 0.0337000000000001, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [35], !- Name + MediumRough, !- Roughness + 0.0452, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [36], !- Name + MediumRough, !- Roughness + 0.0565999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [37], !- Name + MediumRough, !- Roughness + 0.0680999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [40], !- Name + MediumRough, !- Roughness + 0.0793999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [42], !- Name + MediumRough, !- Roughness + 0.0913999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [44], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +! roof insu +Material, + Roof Insulation [18], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [21], !- Name + MediumRough, !- Roughness + 0.2105, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [25], !- Name + MediumRough, !- Roughness + 0.263, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [26], !- Name + MediumRough, !- Roughness + 0.2941, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [31], !- Name + MediumRough, !- Roughness + 0.0337000000000001, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [35], !- Name + MediumRough, !- Roughness + 0.0452, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [36], !- Name + MediumRough, !- Roughness + 0.0565999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [37], !- Name + MediumRough, !- Roughness + 0.0680999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [40], !- Name + MediumRough, !- Roughness + 0.0793999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [42], !- Name + MediumRough, !- Roughness + 0.0913999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [44], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + +Material, + F16 Acoustic tile, !- Name + MediumSmooth, !- Roughness + 0.0191, !- Thickness m + 0.06, !- Conductivity W/m-K + 368, !- Density kg/m3 + 590.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.3, !- Solar Absorptance + 0.3; !- Visible Absorptance + + +Material, + I01 25mm insulation board, !- Name + MediumRough, !- Roughness + 0.0254, !- Thickness m + 0.03, !- Conductivity W/m-K + 43, !- Density kg/m3 + 1210, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.6, !- Solar Absorptance + 0.6; !- Visible Absorptance + +Material, + M11 100mm lightweight concrete, !- Name + MediumRough, !- Roughness + 0.1016, !- Thickness m + 0.53, !- Conductivity W/m-K + 1280, !- Density kg/m3 + 840.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + M11 100mm lightweight concrete 1, !- Name + MediumRough, !- Roughness + 0.1016, !- Thickness m + 0.53, !- Conductivity W/m-K + 1280, !- Density kg/m3 + 840.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + MAT-CC05 4 HW CONCRETE, !- Name + Rough, !- Roughness + 0.1016, !- Thickness m + 1.311, !- Conductivity W/m-K + 2240, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.85, !- Solar Absorptance + 0.85; !- Visible Absorptance + +Material, + Metal Roofing, !- Name + MediumSmooth, !- Roughness + 0.0015, !- Thickness m + 45.006, !- Conductivity W/m-K + 7680, !- Density kg/m3 + 418.4, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.6, !- Solar Absorptance + 0.6; !- Visible Absorptance + +Material, + Pipe Steel, !- Name + Smooth, !- Roughness + 0.003, !- Thickness m + 45.31, !- Conductivity W/m-K + 7833, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material:AirGap, + F04 Wall air space resistance, !- Name + 0.15; !- Thermal Resistance m2-K/W + +Material:AirGap, + F05 Ceiling air space resistance, !- Name + 0.18; !- Thermal Resistance m2-K/W + +Material:NoMass, + CP02 CARPET PAD, !- Name + Smooth, !- Roughness + 0.1, !- Thermal Resistance m2-K/W + 0.9, !- Thermal Absorptance + 0.8, !- Solar Absorptance + 0.8; !- Visible Absorptance + +Material, + G01a 19mm gypsum board, !- Name + MediumSmooth, !- Roughness + 0.019, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +WindowMaterial:SimpleGlazingSystem, + Window Material Simple Glazing System, !- Name + 1.51, !- U-Factor W/m2-K + 0.25; !- Solar Heat Gain Coefficient + +Construction, + Ext Roof, !- Name + roof concrete, !- Layer 1 + Roof Insulation [25]; !- Layer 2 + +Construction, + Ext Wall, !- Name + wall concrete, !- Layer 1 + Wall Insulation [37]; !- Layer 2 + +Construction, + Ext Window, !- Name + Window Material Simple Glazing System; !- Layer 1 + +Construction, + ExtSlabCarpet, !- Name + MAT-CC05 4 HW CONCRETE, !- Layer 1 + CP02 CARPET PAD; !- Layer 2 + +Construction, + Interior Ceiling, !- Name + M11 100mm lightweight concrete, !- Layer 1 + F05 Ceiling air space resistance, !- Layer 2 + F16 Acoustic tile; !- Layer 3 + +Construction, + Interior Floor, !- Name + F16 Acoustic tile, !- Layer 1 + F05 Ceiling air space resistance, !- Layer 2 + M11 100mm lightweight concrete; !- Layer 3 + +Construction, + Interior Wall, !- Name + G01a 19mm gypsum board, !- Layer 1 + F04 Wall air space resistance, !- Layer 2 + G01a 19mm gypsum board; !- Layer 3 +ZoneList, + Space Type 1, !- Name + Thermal Zone 6, !- Zone Name 1 + Thermal Zone 7, !- Zone Name 2 + Thermal Zone 8, !- Zone Name 3 + Thermal Zone 9; !- Zone Name 4 + +Lights, + Lights 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 8.87, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 5.53, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 1; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 7.14, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 1 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 1, !- Sunday Schedule:Day Name + Activity Default Schedule 1, !- Monday Schedule:Day Name + Activity Default Schedule 1, !- Tuesday Schedule:Day Name + Activity Default Schedule 1, !- Wednesday Schedule:Day Name + Activity Default Schedule 1, !- Thursday Schedule:Day Name + Activity Default Schedule 1, !- Friday Schedule:Day Name + Activity Default Schedule 1, !- Saturday Schedule:Day Name + Activity Default Schedule 1, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 1, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 1; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 1, + Fraction, + No, + 01:00, 0.27, !- Value Until Time + 02:00, 0.27, !- Value Until Time + 03:00, 0.27, !- Value Until Time + 04:00, 0.27, !- Value Until Time + 05:00, 0.27, !- Value Until Time + 06:00, 0.27, !- Value Until Time + 07:00, 0.75, !- Value Until Time + 08:00, 0.75, !- Value Until Time + 09:00, 0.75, !- Value Until Time + 10:00, 0.75, !- Value Until Time + 11:00, 0.75, !- Value Until Time + 12:00, 0.75, !- Value Until Time + 13:00, 0.75, !- Value Until Time + 14:00, 0.75, !- Value Until Time + 15:00, 0.27, !- Value Until Time + 16:00, 0.27, !- Value Until Time + 17:00, 0.27, !- Value Until Time + 18:00, 0.27, !- Value Until Time + 19:00, 0.27, !- Value Until Time + 20:00, 0.27, !- Value Until Time + 21:00, 0.27, !- Value Until Time + 22:00, 0.27, !- Value Until Time + 23:00, 0.27, !- Value Until Time + 24:00, 0.27; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 1, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 1, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + +ZoneList, + Space Type 2, !- Name + Thermal Zone 1, !- Zone Name 1 + Thermal Zone 2, !- Zone Name 2 + Thermal Zone 3, !- Zone Name 3 + Thermal Zone 4, !- Zone Name 4 + Thermal Zone 5; !- Zone Name 5 + +Lights, + Lights 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 8.29, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 8.82, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 2; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 3.49, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 2 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 2, !- Sunday Schedule:Day Name + Activity Default Schedule 2, !- Monday Schedule:Day Name + Activity Default Schedule 2, !- Tuesday Schedule:Day Name + Activity Default Schedule 2, !- Wednesday Schedule:Day Name + Activity Default Schedule 2, !- Thursday Schedule:Day Name + Activity Default Schedule 2, !- Friday Schedule:Day Name + Activity Default Schedule 2, !- Saturday Schedule:Day Name + Activity Default Schedule 2, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 2, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 2; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 2, + Fraction, + No, + 01:00, 0.19, !- Value Until Time + 02:00, 0.19, !- Value Until Time + 03:00, 0.19, !- Value Until Time + 04:00, 0.19, !- Value Until Time + 05:00, 0.19, !- Value Until Time + 06:00, 0.19, !- Value Until Time + 07:00, 0.19, !- Value Until Time + 08:00, 0.97, !- Value Until Time + 09:00, 0.97, !- Value Until Time + 10:00, 0.97, !- Value Until Time + 11:00, 0.97, !- Value Until Time + 12:00, 0.97, !- Value Until Time + 13:00, 0.97, !- Value Until Time + 14:00, 0.19, !- Value Until Time + 15:00, 0.19, !- Value Until Time + 16:00, 0.19, !- Value Until Time + 17:00, 0.19, !- Value Until Time + 18:00, 0.19, !- Value Until Time + 19:00, 0.19, !- Value Until Time + 20:00, 0.19, !- Value Until Time + 21:00, 0.19, !- Value Until Time + 22:00, 0.19, !- Value Until Time + 23:00, 0.19, !- Value Until Time + 24:00, 0.19; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 2, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 2, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + +ZoneList, + Space Type 3, !- Name + Thermal Zone 10, !- Zone Name 1 + Thermal Zone 11, !- Zone Name 2 + Thermal Zone 12; !- Zone Name 3 + +Lights, + Lights 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 7.36, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 4.83, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 3; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 4.52, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 3 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 3, !- Sunday Schedule:Day Name + Activity Default Schedule 3, !- Monday Schedule:Day Name + Activity Default Schedule 3, !- Tuesday Schedule:Day Name + Activity Default Schedule 3, !- Wednesday Schedule:Day Name + Activity Default Schedule 3, !- Thursday Schedule:Day Name + Activity Default Schedule 3, !- Friday Schedule:Day Name + Activity Default Schedule 3, !- Saturday Schedule:Day Name + Activity Default Schedule 3, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 3, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 3; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 3, + Fraction, + No, + 01:00, 0.18, !- Value Until Time + 02:00, 0.18, !- Value Until Time + 03:00, 0.18, !- Value Until Time + 04:00, 0.18, !- Value Until Time + 05:00, 0.18, !- Value Until Time + 06:00, 0.18, !- Value Until Time + 07:00, 0.18, !- Value Until Time + 08:00, 0.18, !- Value Until Time + 09:00, 0.18, !- Value Until Time + 10:00, 0.88, !- Value Until Time + 11:00, 0.88, !- Value Until Time + 12:00, 0.88, !- Value Until Time + 13:00, 0.88, !- Value Until Time + 14:00, 0.88, !- Value Until Time + 15:00, 0.88, !- Value Until Time + 16:00, 0.88, !- Value Until Time + 17:00, 0.88, !- Value Until Time + 18:00, 0.18, !- Value Until Time + 19:00, 0.18, !- Value Until Time + 20:00, 0.18, !- Value Until Time + 21:00, 0.18, !- Value Until Time + 22:00, 0.18, !- Value Until Time + 23:00, 0.18, !- Value Until Time + 24:00, 0.18; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 3, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 3, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + + +! ##################################################################################### +! thermostat info for Thermal Zone 1 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 2 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 3 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 4 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 5 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 6 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 7 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 8 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 9 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 10 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 11 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 12 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 1 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 1 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 1, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 1, !- Monday Schedule:Day Name + HtgSetp Default Schedule 1, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 1, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 1, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 1, !- Friday Schedule:Day Name + HtgSetp Default Schedule 1, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 1, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 1, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 1, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 1, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 1, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 1 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 1, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 1, !- Monday Schedule:Day Name + ClgSetp Default Schedule 1, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 1, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 1, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 1, !- Friday Schedule:Day Name + ClgSetp Default Schedule 1, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 1, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 1, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 1, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 2 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 2 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 2, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 2, !- Monday Schedule:Day Name + HtgSetp Default Schedule 2, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 2, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 2, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 2, !- Friday Schedule:Day Name + HtgSetp Default Schedule 2, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 2, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 2, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 2, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 2, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 2, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 2 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 2, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 2, !- Monday Schedule:Day Name + ClgSetp Default Schedule 2, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 2, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 2, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 2, !- Friday Schedule:Day Name + ClgSetp Default Schedule 2, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 2, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 2, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 2, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 3 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 3 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 3, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 3, !- Monday Schedule:Day Name + HtgSetp Default Schedule 3, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 3, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 3, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 3, !- Friday Schedule:Day Name + HtgSetp Default Schedule 3, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 3, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 3, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 3, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 3, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 3, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 3 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 3, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 3, !- Monday Schedule:Day Name + ClgSetp Default Schedule 3, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 3, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 3, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 3, !- Friday Schedule:Day Name + ClgSetp Default Schedule 3, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 3, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 3, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 3, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 4 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 4 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 4, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 4, !- Monday Schedule:Day Name + HtgSetp Default Schedule 4, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 4, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 4, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 4, !- Friday Schedule:Day Name + HtgSetp Default Schedule 4, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 4, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 4, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 4, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 4, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 4; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 4, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 4 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 4, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 4, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 4 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 4, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 4, !- Monday Schedule:Day Name + ClgSetp Default Schedule 4, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 4, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 4, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 4, !- Friday Schedule:Day Name + ClgSetp Default Schedule 4, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 4, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 4, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 4, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 4, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 4; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 4, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 4 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 5 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 5 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 5, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 5, !- Monday Schedule:Day Name + HtgSetp Default Schedule 5, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 5, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 5, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 5, !- Friday Schedule:Day Name + HtgSetp Default Schedule 5, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 5, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 5, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 5, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 5, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 5; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 5, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 5 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 5, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 5, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 5 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 5, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 5, !- Monday Schedule:Day Name + ClgSetp Default Schedule 5, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 5, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 5, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 5, !- Friday Schedule:Day Name + ClgSetp Default Schedule 5, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 5, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 5, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 5, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 5, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 5; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 5, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 5 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 5, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 5, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 6 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 6 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 6, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 6, !- Monday Schedule:Day Name + HtgSetp Default Schedule 6, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 6, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 6, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 6, !- Friday Schedule:Day Name + HtgSetp Default Schedule 6, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 6, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 6, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 6, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 6, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 6; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 6, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 6 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 6, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 6, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 6 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 6, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 6, !- Monday Schedule:Day Name + ClgSetp Default Schedule 6, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 6, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 6, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 6, !- Friday Schedule:Day Name + ClgSetp Default Schedule 6, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 6, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 6, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 6, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 6, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 6; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 6, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 6 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 6, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 6, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 7 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 7 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 7, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 7, !- Monday Schedule:Day Name + HtgSetp Default Schedule 7, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 7, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 7, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 7, !- Friday Schedule:Day Name + HtgSetp Default Schedule 7, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 7, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 7, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 7, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 7, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 7; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 7, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 7 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 7, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 7, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 7 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 7, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 7, !- Monday Schedule:Day Name + ClgSetp Default Schedule 7, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 7, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 7, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 7, !- Friday Schedule:Day Name + ClgSetp Default Schedule 7, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 7, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 7, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 7, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 7, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 7; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 7, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 7 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 7, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 7, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 8 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 8 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 8, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 8, !- Monday Schedule:Day Name + HtgSetp Default Schedule 8, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 8, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 8, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 8, !- Friday Schedule:Day Name + HtgSetp Default Schedule 8, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 8, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 8, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 8, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 8, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 8; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 8, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 8 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 8, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 8, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 8 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 8, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 8, !- Monday Schedule:Day Name + ClgSetp Default Schedule 8, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 8, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 8, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 8, !- Friday Schedule:Day Name + ClgSetp Default Schedule 8, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 8, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 8, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 8, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 8, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 8; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 8, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 8 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 8, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 8, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 9 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 9 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 9, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 9, !- Monday Schedule:Day Name + HtgSetp Default Schedule 9, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 9, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 9, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 9, !- Friday Schedule:Day Name + HtgSetp Default Schedule 9, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 9, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 9, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 9, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 9, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 9; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 9, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 9 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 9, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 9, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 9 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 9, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 9, !- Monday Schedule:Day Name + ClgSetp Default Schedule 9, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 9, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 9, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 9, !- Friday Schedule:Day Name + ClgSetp Default Schedule 9, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 9, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 9, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 9, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 9, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 9; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 9, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 9 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 9, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 9, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 10 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 10 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 10, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 10, !- Monday Schedule:Day Name + HtgSetp Default Schedule 10, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 10, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 10, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 10, !- Friday Schedule:Day Name + HtgSetp Default Schedule 10, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 10, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 10, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 10, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 10, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 10; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 10, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 10 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 10, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 10, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 10 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 10, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 10, !- Monday Schedule:Day Name + ClgSetp Default Schedule 10, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 10, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 10, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 10, !- Friday Schedule:Day Name + ClgSetp Default Schedule 10, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 10, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 10, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 10, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 10, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 10; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 10, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 10 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 10, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 10, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 11 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 11 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 11, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 11, !- Monday Schedule:Day Name + HtgSetp Default Schedule 11, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 11, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 11, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 11, !- Friday Schedule:Day Name + HtgSetp Default Schedule 11, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 11, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 11, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 11, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 11, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 11; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 11, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 11 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 11, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 11, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 11 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 11, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 11, !- Monday Schedule:Day Name + ClgSetp Default Schedule 11, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 11, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 11, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 11, !- Friday Schedule:Day Name + ClgSetp Default Schedule 11, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 11, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 11, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 11, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 11, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 11; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 11, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 11 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 11, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 11, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 12 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 12 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 12, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 12, !- Monday Schedule:Day Name + HtgSetp Default Schedule 12, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 12, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 12, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 12, !- Friday Schedule:Day Name + HtgSetp Default Schedule 12, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 12, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 12, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 12, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 12, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 12; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 12, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 12 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 12, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 12, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 12 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 12, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 12, !- Monday Schedule:Day Name + ClgSetp Default Schedule 12, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 12, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 12, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 12, !- Friday Schedule:Day Name + ClgSetp Default Schedule 12, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 12, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 12, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 12, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 12, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 12; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 12, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 12 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 12, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 12, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + + +Schedule:Day:Interval, + ClgSetp Default Schedule 1, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 1, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 2, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 2, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 3, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 3, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 4, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 4, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 5, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 5, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 6, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 6, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 7, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 7, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 8, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 8, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 9, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 9, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 10, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 10, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 11, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 11, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 12, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 12, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + +! ==================================== Execution 2 Successful ==================================== +! ==================================== Execution 3 Started ==================================== + +Controller:MechanicalVentilation, + Controller Mechanical Ventilation 1, !- Name + Always On Discrete, !- Availability Schedule Name + No, !- Demand Controlled Ventilation + ZoneSum, !- System Outdoor Air Method + , !- Zone Maximum Outdoor Air Fraction {dimensionless} + Thermal Zone 1, !- Zone or ZoneList Name 1 + Ventilation 1, !- Design Specification Outdoor Air Object Name 1 + , !- Design Specification Zone Air Distribution Object Name 1 + Thermal Zone 2, !- Zone or ZoneList Name 2 + Ventilation 2, !- Design Specification Outdoor Air Object Name 2 + , !- Design Specification Zone Air Distribution Object Name 2 + Thermal Zone 3, !- Zone or ZoneList Name 3 + Ventilation 3, !- Design Specification Outdoor Air Object Name 3 + , !- Design Specification Zone Air Distribution Object Name 3 + Thermal Zone 4, !- Zone or ZoneList Name 4 + Ventilation 4, !- Design Specification Outdoor Air Object Name 4 + ; !- Design Specification Zone Air Distribution Object Name 4 + +! add the air supply temp for different ahu + + +Schedule:Day:Interval, + Deck_Temperature_Default 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.2; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Summer_Design_Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.2; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Winter_Design_Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.2; !- Value Until Time 1 + +Schedule:Week:Daily, + Deck_Temperature 1 Week Rule - Jan1-Dec31, !- Name + Deck_Temperature_Default 1, !- Sunday Schedule:Day Name + Deck_Temperature_Default 1, !- Monday Schedule:Day Name + Deck_Temperature_Default 1, !- Tuesday Schedule:Day Name + Deck_Temperature_Default 1, !- Wednesday Schedule:Day Name + Deck_Temperature_Default 1, !- Thursday Schedule:Day Name + Deck_Temperature_Default 1, !- Friday Schedule:Day Name + Deck_Temperature_Default 1, !- Saturday Schedule:Day Name + Deck_Temperature_Default 1, !- Holiday Schedule:Day Name + Deck_Temperature_Summer_Design_Day 1, !- SummerDesignDay Schedule:Day Name + Deck_Temperature_Winter_Design_Day 1, !- WinterDesignDay Schedule:Day Name + Deck_Temperature_Default 1, !- CustomDay1 Schedule:Day Name + Deck_Temperature_Default 1; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Deck_Temperature 1, !- Name + Temperature 37, !- Schedule Type Limits Name + Deck_Temperature 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +AirLoopHVAC:SupplyPath, + Packaged Rooftop Air Conditioner 1 Node Air Supply 1 Supply Path, !- Name + Node Air Supply 1, !- Supply Air Path Inlet Node Name + AirLoopHVAC:ZoneSplitter, !- Component Object Type 1 + Air Loop HVAC Zone Splitter 1; !- Component Name 1 + +AirLoopHVAC:ZoneSplitter, + Air Loop HVAC Zone Splitter 1, !- Name + Node Air Supply 1, !- Inlet Node Name + Node Air Thermal Zone 1 Terminal, !- Outlet Node Name 1 + Node Air Thermal Zone 2 Terminal, !- Outlet Node Name 2 + Node Air Thermal Zone 3 Terminal, !- Outlet Node Name 3 + Node Air Thermal Zone 4 Terminal; !- Outlet Node Name 4 + +AirLoopHVAC:ReturnPath, + Packaged Rooftop Air Conditioner 1 Return Path, !- Name + Node Air Return 1, !- Return Air Path Outlet Node Name + AirLoopHVAC:ZoneMixer, !- Component Object Type 1 + Air Loop HVAC Zone Mixer 1; !- Component Name 1 + +AirLoopHVAC:ZoneMixer, + Air Loop HVAC Zone Mixer 1, !- Name + Node Air Return 1, !- Outlet Node Name + Node Air Thermal Zone 1 Out, !- Inlet Node Name 1 + Node Air Thermal Zone 2 Out, !- Inlet Node Name 2 + Node Air Thermal Zone 3 Out, !- Inlet Node Name 3 + Node Air Thermal Zone 4 Out; !- Inlet Node Name 4 + +! AHU loop 1, + +AirLoopHVAC, + Packaged Rooftop Air Conditioner 1, !- Name + , !- Controller List Name + Packaged Rooftop Air Conditioner 1Availability Manager List, !- Availability Manager List Name + AutoSize, !- Design Supply Air Flow Rate m3/s + Packaged Rooftop Air Conditioner 1 Supply Branches, !- Branch List Name + , !- Connector List Name + Node Air Deck Return 1, !- Supply Side Inlet Node Name + Node Air Return 1, !- Demand Side Outlet Node Name + Packaged Rooftop Air Conditioner 1 Demand Inlet Nodes, !- Demand Side Inlet Node Names + Packaged Rooftop Air Conditioner 1 Supply Outlet Nodes, !- Supply Side Outlet Node Names + 1; !- Design Return Air Flow Fraction of Supply Air Flow + +NodeList, + Packaged Rooftop Air Conditioner 1 Supply Outlet Nodes, !- Name + Node Air Deck Supply 1; !- Node Name 1 + +NodeList, + Packaged Rooftop Air Conditioner 1 Demand Inlet Nodes, !- Name + Node Air Supply 1; !- Node Name 1 + +Sizing:System, + Packaged Rooftop Air Conditioner 1, !- AirLoop Name + Sensible, !- Type of Load to Size On + Autosize, !- Design Outdoor Air Flow Rate m3/s + 0.3, !- Central Heating Maximum System Air Flow Ratio + 7, !- Preheat Design Temperature C + 0.008, !- Preheat Design Humidity Ratio kgWater/kgDryAir + 12.8, !- Precool Design Temperature C + 0.008, !- Precool Design Humidity Ratio kgWater/kgDryAir + 13.2, !- Central Cooling Design Supply Air Temperature C + 47.5, !- Central Heating Design Supply Air Temperature C + NonCoincident, !- Type of Zone Sum to Use + Yes, !- 100% Outdoor Air in Cooling + Yes, !- 100% Outdoor Air in Heating + 0.0085, !- Central Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Central Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + DesignDay, !- Cooling Supply Air Flow Rate Method + 0, !- Cooling Supply Air Flow Rate m3/s + 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate + 3.9475456e-05, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity m3/s-W + DesignDay, !- Heating Supply Air Flow Rate Method + 0, !- Heating Supply Air Flow Rate m3/s + 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate + 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate + 3.1588213e-05, !- Heating Supply Air Flow Rate Per Unit Heating Capacity m3/s-W + ZoneSum, !- System Outdoor Air Method + 1, !- Zone Maximum Outdoor Air Fraction dimensionless + CoolingDesignCapacity, !- Cooling Design Capacity Method + Autosize, !- Cooling Design Capacity W + 234.7, !- Cooling Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Cooling Design Capacity + HeatingDesignCapacity, !- Heating Design Capacity Method + Autosize, !- Heating Design Capacity W + 157, !- Heating Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Heating Design Capacity + OnOff, !- Central Cooling Capacity Control Method + Autosize; !- Occupant Diversity + +AvailabilityManagerAssignmentList, + Packaged Rooftop Air Conditioner 1Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Packaged Rooftop Air Conditioner 1 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Packaged Rooftop Air Conditioner 1 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +BranchList, + Packaged Rooftop Air Conditioner 1 Supply Branches, !- Name + Packaged Rooftop Air Conditioner 1 Main Branch; !- Branch Name 1 + +Branch, + Packaged Rooftop Air Conditioner 1 Main Branch, !- Name + , !- Pressure Drop Curve Name + AirLoopHVAC:OutdoorAirSystem, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 1, !- Component Name 1 + Node Air Deck Return 1, !- Component Inlet Node Name 1 + Node Air Deck Mixed 1, !- Component Outlet Node Name 1 + CoilSystem:Cooling:DX, !- Component Object Type 2 + 1 Spd DX Clg Coil 1 CoilSystem, !- Component Name 2 + Node Air Deck Mixed 1, !- Component Inlet Node Name 2 + Node Air Deck Cooling 1, !- Component Outlet Node Name 2 + Coil:Heating:Fuel, !- Component Object Type 3 + Gas Htg Coil 1, !- Component Name 3 + Node Air Deck Cooling 1, !- Component Inlet Node Name 3 + Node Air Deck Heating 1, !- Component Outlet Node Name 3 + Fan:ConstantVolume, !- Component Object Type 4 + Const Spd Fan 1, !- Component Name 4 + Node Air Deck Heating 1, !- Component Inlet Node Name 4 + Node Air Deck Supply 1; !- Component Outlet Node Name 4 + +AirLoopHVAC:OutdoorAirSystem, + Air Loop HVAC Outdoor Air System 1, !- Name + Air Loop HVAC Outdoor Air System 1 Controller List, !- Controller List Name + Air Loop HVAC Outdoor Air System 1 Equipment List; !- Outdoor Air Equipment List Name + +AirLoopHVAC:ControllerList, + Air Loop HVAC Outdoor Air System 1 Controller List, !- Name + Controller:OutdoorAir, !- Controller Object Type 1 + Controller Outdoor Air 1; !- Controller Name 1 + +Controller:OutdoorAir, + Controller Outdoor Air 1, !- Name + Node Air Deck Exhaust 1, !- Relief Air Outlet Node Name + Node Air Deck Return 1, !- Return Air Node Name + Node Air Deck Mixed 1, !- Mixed Air Node Name + Node Air Deck Fresh 1, !- Actuator Node Name + 0, !- Minimum Outdoor Air Flow Rate m3/s + Autosize, !- Maximum Outdoor Air Flow Rate m3/s + DifferentialEnthalpy, !- Economizer Control Type + ModulateFlow, !- Economizer Control Action Type + 28, !- Economizer Maximum Limit Dry-Bulb Temperature C + 64000, !- Economizer Maximum Limit Enthalpy J/kg + , !- Economizer Maximum Limit Dewpoint Temperature C + , !- Electronic Enthalpy Limit Curve Name + -100, !- Economizer Minimum Limit Dry-Bulb Temperature C + NoLockout, !- Lockout Type + FixedMinimum, !- Minimum Limit Type + , !- Minimum Outdoor Air Schedule Name + , !- Minimum Fraction of Outdoor Air Schedule Name + , !- Maximum Fraction of Outdoor Air Schedule Name + Controller Mechanical Ventilation 1, !- Mechanical Ventilation Controller Name + , !- Time of Day Economizer Control Schedule Name + No, !- High Humidity Control + , !- Humidistat Control Zone Name + , !- High Humidity Outdoor Air Flow Ratio + Yes, !- Control High Indoor Humidity Based on Outdoor Humidity Ratio + BypassWhenWithinEconomizerLimits; !- Heat Recovery Bypass Control Type + +AvailabilityManagerAssignmentList, + Air Loop HVAC Outdoor Air System 1 Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Air Loop HVAC Outdoor Air System 1 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Air Loop HVAC Outdoor Air System 1 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +OutdoorAir:NodeList, + Node Air Deck Fresh 1; !- Node or NodeList Name 1 + +AirLoopHVAC:OutdoorAirSystem:EquipmentList, + Air Loop HVAC Outdoor Air System 1 Equipment List, !- Name + OutdoorAir:Mixer, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 1 Outdoor Air Mixer; !- Component Name 1 + +OutdoorAir:Mixer, + Air Loop HVAC Outdoor Air System 1 Outdoor Air Mixer, !- Name + Node Air Deck Mixed 1, !- Mixed Air Node Name + Node Air Deck Fresh 1, !- Outdoor Air Stream Node Name + Node Air Deck Exhaust 1, !- Relief Air Stream Node Name + Node Air Deck Return 1; !- Return Air Stream Node Name + +SetpointManager:MixedAir, + Node Air Deck Mixed 1 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 1, !- Reference Setpoint Node Name + Node Air Deck Heating 1, !- Fan Inlet Node Name + Node Air Deck Supply 1, !- Fan Outlet Node Name + Node Air Deck Mixed 1; !- Setpoint Node or NodeList Name + +CoilSystem:Cooling:DX, + 1 Spd DX Clg Coil 1 CoilSystem, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Node Air Deck Mixed 1, !- DX Cooling Coil System Inlet Node Name + Node Air Deck Cooling 1, !- DX Cooling Coil System Outlet Node Name + Node Air Deck Cooling 1, !- DX Cooling Coil System Sensor Node Name + Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type + 1 Spd DX Clg Coil 1; !- Cooling Coil Name + +SetpointManager:MixedAir, + Node Air Deck Cooling 1 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 1, !- Reference Setpoint Node Name + Node Air Deck Heating 1, !- Fan Inlet Node Name + Node Air Deck Supply 1, !- Fan Outlet Node Name + Node Air Deck Cooling 1; !- Setpoint Node or NodeList Name + +Coil:Cooling:DX:SingleSpeed, + 1 Spd DX Clg Coil 1, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + 3.61, !- Gross Rated Cooling COP W/W + Autosize, !- Rated Air Flow Rate m3/s + 773.3, !- Rated Evaporator Fan Power Per Volume Flow Rate W/(m3/s) + Node Air Deck Mixed 1, !- Air Inlet Node Name + Node Air Deck Cooling 1, !- Air Outlet Node Name + OS:Curve:Biquadratic 1, !- Total Cooling Capacity Function of Temperature Curve Name + OS:Curve:Quadratic 1, !- Total Cooling Capacity Function of Flow Fraction Curve Name + OS:Curve:Biquadratic 2, !- Energy Input Ratio Function of Temperature Curve Name + OS:Curve:Quadratic 2, !- Energy Input Ratio Function of Flow Fraction Curve Name + OS:Curve:Quadratic 3, !- Part Load Fraction Correlation Curve Name + -25, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation C + , !- Nominal Time for Condensate Removal to Begin s + , !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity + , !- Maximum Cycling Rate cycles/hr + , !- Latent Capacity Time Constant s + , !- Condenser Air Inlet Node Name + AirCooled, !- Condenser Type + 0, !- Evaporative Condenser Effectiveness + Autosize, !- Evaporative Condenser Air Flow Rate m3/s + Autosize, !- Evaporative Condenser Pump Rated Power Consumption W + 0, !- Crankcase Heater Capacity W + 0, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation C + , !- Supply Water Storage Tank Name + , !- Condensate Collection Water Storage Tank Name + 0, !- Basin Heater Capacity W/K + 10; !- Basin Heater Setpoint Temperature C + +Coil:Heating:Fuel, + Gas Htg Coil 1, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Coal, !- Fuel Type + 0.84, !- Burner Efficiency + 4599, !- Nominal Capacity W + Node Air Deck Cooling 1, !- Air Inlet Node Name + Node Air Deck Heating 1, !- Air Outlet Node Name + Node Air Deck Heating 1, !- Temperature Setpoint Node Name + 0, !- Parasitic Electric Load W + , !- Part Load Fraction Correlation Curve Name + 0; !- Parasitic Fuel Load W + +SetpointManager:MixedAir, + Node Air Deck Heating 1 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 1, !- Reference Setpoint Node Name + Node Air Deck Heating 1, !- Fan Inlet Node Name + Node Air Deck Supply 1, !- Fan Outlet Node Name + Node Air Deck Heating 1; !- Setpoint Node or NodeList Name + +Fan:ConstantVolume, + Const Spd Fan 1, !- Name + Always On Discrete, !- Availability Schedule Name + 0.62, !- Fan Total Efficiency + 862, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.9, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + Node Air Deck Heating 1, !- Air Inlet Node Name + Node Air Deck Supply 1, !- Air Outlet Node Name + ; !- End-Use Subcategory + + +SetpointManager:Scheduled, + Setpoint Manager Scheduled Air Duck 1, !- Name + Temperature, !- Control Variable + Deck_Temperature 1, !- Schedule Name + Node Air Deck Supply 1; !- Setpoint Node or NodeList Name + +Controller:MechanicalVentilation, + Controller Mechanical Ventilation 2, !- Name + Always On Discrete, !- Availability Schedule Name + No, !- Demand Controlled Ventilation + ZoneSum, !- System Outdoor Air Method + , !- Zone Maximum Outdoor Air Fraction {dimensionless} + Thermal Zone 5, !- Zone or ZoneList Name 1 + Ventilation 5, !- Design Specification Outdoor Air Object Name 1 + , !- Design Specification Zone Air Distribution Object Name 1 + Thermal Zone 6, !- Zone or ZoneList Name 2 + Ventilation 6, !- Design Specification Outdoor Air Object Name 2 + , !- Design Specification Zone Air Distribution Object Name 2 + Thermal Zone 7, !- Zone or ZoneList Name 3 + Ventilation 7, !- Design Specification Outdoor Air Object Name 3 + ; !- Design Specification Zone Air Distribution Object Name 3 + +! add the air supply temp for different ahu + + +Schedule:Day:Interval, + Deck_Temperature_Default 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.7; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Summer_Design_Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.7; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Winter_Design_Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.7; !- Value Until Time 1 + +Schedule:Week:Daily, + Deck_Temperature 2 Week Rule - Jan1-Dec31, !- Name + Deck_Temperature_Default 2, !- Sunday Schedule:Day Name + Deck_Temperature_Default 2, !- Monday Schedule:Day Name + Deck_Temperature_Default 2, !- Tuesday Schedule:Day Name + Deck_Temperature_Default 2, !- Wednesday Schedule:Day Name + Deck_Temperature_Default 2, !- Thursday Schedule:Day Name + Deck_Temperature_Default 2, !- Friday Schedule:Day Name + Deck_Temperature_Default 2, !- Saturday Schedule:Day Name + Deck_Temperature_Default 2, !- Holiday Schedule:Day Name + Deck_Temperature_Summer_Design_Day 2, !- SummerDesignDay Schedule:Day Name + Deck_Temperature_Winter_Design_Day 2, !- WinterDesignDay Schedule:Day Name + Deck_Temperature_Default 2, !- CustomDay1 Schedule:Day Name + Deck_Temperature_Default 2; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Deck_Temperature 2, !- Name + Temperature 37, !- Schedule Type Limits Name + Deck_Temperature 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +AirLoopHVAC:SupplyPath, + Packaged Rooftop Air Conditioner 2 Node Air Supply 2 Supply Path, !- Name + Node Air Supply 2, !- Supply Air Path Inlet Node Name + AirLoopHVAC:ZoneSplitter, !- Component Object Type 1 + Air Loop HVAC Zone Splitter 2; !- Component Name 1 + +AirLoopHVAC:ZoneSplitter, + Air Loop HVAC Zone Splitter 2, !- Name + Node Air Supply 2, !- Inlet Node Name + Node Air Thermal Zone 5 Terminal, !- Outlet Node Name 1 + Node Air Thermal Zone 6 Terminal, !- Outlet Node Name 2 + Node Air Thermal Zone 7 Terminal; !- Outlet Node Name 3 + +AirLoopHVAC:ReturnPath, + Packaged Rooftop Air Conditioner 2 Return Path, !- Name + Node Air Return 2, !- Return Air Path Outlet Node Name + AirLoopHVAC:ZoneMixer, !- Component Object Type 1 + Air Loop HVAC Zone Mixer 2; !- Component Name 1 + +AirLoopHVAC:ZoneMixer, + Air Loop HVAC Zone Mixer 2, !- Name + Node Air Return 2, !- Outlet Node Name + Node Air Thermal Zone 5 Out, !- Inlet Node Name 1 + Node Air Thermal Zone 6 Out, !- Inlet Node Name 2 + Node Air Thermal Zone 7 Out; !- Inlet Node Name 3 + +! AHU loop 2, + +AirLoopHVAC, + Packaged Rooftop Air Conditioner 2, !- Name + , !- Controller List Name + Packaged Rooftop Air Conditioner 2Availability Manager List, !- Availability Manager List Name + AutoSize, !- Design Supply Air Flow Rate m3/s + Packaged Rooftop Air Conditioner 2 Supply Branches, !- Branch List Name + , !- Connector List Name + Node Air Deck Return 2, !- Supply Side Inlet Node Name + Node Air Return 2, !- Demand Side Outlet Node Name + Packaged Rooftop Air Conditioner 2 Demand Inlet Nodes, !- Demand Side Inlet Node Names + Packaged Rooftop Air Conditioner 2 Supply Outlet Nodes, !- Supply Side Outlet Node Names + 1; !- Design Return Air Flow Fraction of Supply Air Flow + +NodeList, + Packaged Rooftop Air Conditioner 2 Supply Outlet Nodes, !- Name + Node Air Deck Supply 2; !- Node Name 1 + +NodeList, + Packaged Rooftop Air Conditioner 2 Demand Inlet Nodes, !- Name + Node Air Supply 2; !- Node Name 1 + +Sizing:System, + Packaged Rooftop Air Conditioner 2, !- AirLoop Name + Sensible, !- Type of Load to Size On + Autosize, !- Design Outdoor Air Flow Rate m3/s + 0.3, !- Central Heating Maximum System Air Flow Ratio + 7, !- Preheat Design Temperature C + 0.008, !- Preheat Design Humidity Ratio kgWater/kgDryAir + 12.8, !- Precool Design Temperature C + 0.008, !- Precool Design Humidity Ratio kgWater/kgDryAir + 18.7, !- Central Cooling Design Supply Air Temperature C + 41.9, !- Central Heating Design Supply Air Temperature C + NonCoincident, !- Type of Zone Sum to Use + Yes, !- 100% Outdoor Air in Cooling + Yes, !- 100% Outdoor Air in Heating + 0.0085, !- Central Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Central Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + DesignDay, !- Cooling Supply Air Flow Rate Method + 0, !- Cooling Supply Air Flow Rate m3/s + 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate + 3.9475456e-05, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity m3/s-W + DesignDay, !- Heating Supply Air Flow Rate Method + 0, !- Heating Supply Air Flow Rate m3/s + 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate + 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate + 3.1588213e-05, !- Heating Supply Air Flow Rate Per Unit Heating Capacity m3/s-W + ZoneSum, !- System Outdoor Air Method + 1, !- Zone Maximum Outdoor Air Fraction dimensionless + CoolingDesignCapacity, !- Cooling Design Capacity Method + Autosize, !- Cooling Design Capacity W + 234.7, !- Cooling Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Cooling Design Capacity + HeatingDesignCapacity, !- Heating Design Capacity Method + Autosize, !- Heating Design Capacity W + 157, !- Heating Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Heating Design Capacity + OnOff, !- Central Cooling Capacity Control Method + Autosize; !- Occupant Diversity + +AvailabilityManagerAssignmentList, + Packaged Rooftop Air Conditioner 2Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Packaged Rooftop Air Conditioner 2 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Packaged Rooftop Air Conditioner 2 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +BranchList, + Packaged Rooftop Air Conditioner 2 Supply Branches, !- Name + Packaged Rooftop Air Conditioner 2 Main Branch; !- Branch Name 1 + +Branch, + Packaged Rooftop Air Conditioner 2 Main Branch, !- Name + , !- Pressure Drop Curve Name + AirLoopHVAC:OutdoorAirSystem, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 2, !- Component Name 1 + Node Air Deck Return 2, !- Component Inlet Node Name 1 + Node Air Deck Mixed 2, !- Component Outlet Node Name 1 + CoilSystem:Cooling:DX, !- Component Object Type 2 + 1 Spd DX Clg Coil 2 CoilSystem, !- Component Name 2 + Node Air Deck Mixed 2, !- Component Inlet Node Name 2 + Node Air Deck Cooling 2, !- Component Outlet Node Name 2 + Coil:Heating:Fuel, !- Component Object Type 3 + Gas Htg Coil 2, !- Component Name 3 + Node Air Deck Cooling 2, !- Component Inlet Node Name 3 + Node Air Deck Heating 2, !- Component Outlet Node Name 3 + Fan:ConstantVolume, !- Component Object Type 4 + Const Spd Fan 2, !- Component Name 4 + Node Air Deck Heating 2, !- Component Inlet Node Name 4 + Node Air Deck Supply 2; !- Component Outlet Node Name 4 + +AirLoopHVAC:OutdoorAirSystem, + Air Loop HVAC Outdoor Air System 2, !- Name + Air Loop HVAC Outdoor Air System 2 Controller List, !- Controller List Name + Air Loop HVAC Outdoor Air System 2 Equipment List; !- Outdoor Air Equipment List Name + +AirLoopHVAC:ControllerList, + Air Loop HVAC Outdoor Air System 2 Controller List, !- Name + Controller:OutdoorAir, !- Controller Object Type 1 + Controller Outdoor Air 2; !- Controller Name 1 + +Controller:OutdoorAir, + Controller Outdoor Air 2, !- Name + Node Air Deck Exhaust 2, !- Relief Air Outlet Node Name + Node Air Deck Return 2, !- Return Air Node Name + Node Air Deck Mixed 2, !- Mixed Air Node Name + Node Air Deck Fresh 2, !- Actuator Node Name + 0, !- Minimum Outdoor Air Flow Rate m3/s + Autosize, !- Maximum Outdoor Air Flow Rate m3/s + DifferentialEnthalpy, !- Economizer Control Type + ModulateFlow, !- Economizer Control Action Type + 28, !- Economizer Maximum Limit Dry-Bulb Temperature C + 64000, !- Economizer Maximum Limit Enthalpy J/kg + , !- Economizer Maximum Limit Dewpoint Temperature C + , !- Electronic Enthalpy Limit Curve Name + -100, !- Economizer Minimum Limit Dry-Bulb Temperature C + NoLockout, !- Lockout Type + FixedMinimum, !- Minimum Limit Type + , !- Minimum Outdoor Air Schedule Name + , !- Minimum Fraction of Outdoor Air Schedule Name + , !- Maximum Fraction of Outdoor Air Schedule Name + Controller Mechanical Ventilation 2, !- Mechanical Ventilation Controller Name + , !- Time of Day Economizer Control Schedule Name + No, !- High Humidity Control + , !- Humidistat Control Zone Name + , !- High Humidity Outdoor Air Flow Ratio + Yes, !- Control High Indoor Humidity Based on Outdoor Humidity Ratio + BypassWhenWithinEconomizerLimits; !- Heat Recovery Bypass Control Type + +AvailabilityManagerAssignmentList, + Air Loop HVAC Outdoor Air System 2 Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Air Loop HVAC Outdoor Air System 2 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Air Loop HVAC Outdoor Air System 2 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +OutdoorAir:NodeList, + Node Air Deck Fresh 2; !- Node or NodeList Name 1 + +AirLoopHVAC:OutdoorAirSystem:EquipmentList, + Air Loop HVAC Outdoor Air System 2 Equipment List, !- Name + OutdoorAir:Mixer, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 2 Outdoor Air Mixer; !- Component Name 1 + +OutdoorAir:Mixer, + Air Loop HVAC Outdoor Air System 2 Outdoor Air Mixer, !- Name + Node Air Deck Mixed 2, !- Mixed Air Node Name + Node Air Deck Fresh 2, !- Outdoor Air Stream Node Name + Node Air Deck Exhaust 2, !- Relief Air Stream Node Name + Node Air Deck Return 2; !- Return Air Stream Node Name + +SetpointManager:MixedAir, + Node Air Deck Mixed 2 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 2, !- Reference Setpoint Node Name + Node Air Deck Heating 2, !- Fan Inlet Node Name + Node Air Deck Supply 2, !- Fan Outlet Node Name + Node Air Deck Mixed 2; !- Setpoint Node or NodeList Name + +CoilSystem:Cooling:DX, + 1 Spd DX Clg Coil 2 CoilSystem, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Node Air Deck Mixed 2, !- DX Cooling Coil System Inlet Node Name + Node Air Deck Cooling 2, !- DX Cooling Coil System Outlet Node Name + Node Air Deck Cooling 2, !- DX Cooling Coil System Sensor Node Name + Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type + 1 Spd DX Clg Coil 2; !- Cooling Coil Name + +SetpointManager:MixedAir, + Node Air Deck Cooling 2 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 2, !- Reference Setpoint Node Name + Node Air Deck Heating 2, !- Fan Inlet Node Name + Node Air Deck Supply 2, !- Fan Outlet Node Name + Node Air Deck Cooling 2; !- Setpoint Node or NodeList Name + +Coil:Cooling:DX:SingleSpeed, + 1 Spd DX Clg Coil 2, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + 3.55, !- Gross Rated Cooling COP W/W + Autosize, !- Rated Air Flow Rate m3/s + 773.3, !- Rated Evaporator Fan Power Per Volume Flow Rate W/(m3/s) + Node Air Deck Mixed 2, !- Air Inlet Node Name + Node Air Deck Cooling 2, !- Air Outlet Node Name + OS:Curve:Biquadratic 1, !- Total Cooling Capacity Function of Temperature Curve Name + OS:Curve:Quadratic 1, !- Total Cooling Capacity Function of Flow Fraction Curve Name + OS:Curve:Biquadratic 2, !- Energy Input Ratio Function of Temperature Curve Name + OS:Curve:Quadratic 2, !- Energy Input Ratio Function of Flow Fraction Curve Name + OS:Curve:Quadratic 3, !- Part Load Fraction Correlation Curve Name + -25, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation C + , !- Nominal Time for Condensate Removal to Begin s + , !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity + , !- Maximum Cycling Rate cycles/hr + , !- Latent Capacity Time Constant s + , !- Condenser Air Inlet Node Name + AirCooled, !- Condenser Type + 0, !- Evaporative Condenser Effectiveness + Autosize, !- Evaporative Condenser Air Flow Rate m3/s + Autosize, !- Evaporative Condenser Pump Rated Power Consumption W + 0, !- Crankcase Heater Capacity W + 0, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation C + , !- Supply Water Storage Tank Name + , !- Condensate Collection Water Storage Tank Name + 0, !- Basin Heater Capacity W/K + 10; !- Basin Heater Setpoint Temperature C + +Coil:Heating:Fuel, + Gas Htg Coil 2, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Coal, !- Fuel Type + 0.82, !- Burner Efficiency + 49254, !- Nominal Capacity W + Node Air Deck Cooling 2, !- Air Inlet Node Name + Node Air Deck Heating 2, !- Air Outlet Node Name + Node Air Deck Heating 2, !- Temperature Setpoint Node Name + 0, !- Parasitic Electric Load W + , !- Part Load Fraction Correlation Curve Name + 0; !- Parasitic Fuel Load W + +SetpointManager:MixedAir, + Node Air Deck Heating 2 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 2, !- Reference Setpoint Node Name + Node Air Deck Heating 2, !- Fan Inlet Node Name + Node Air Deck Supply 2, !- Fan Outlet Node Name + Node Air Deck Heating 2; !- Setpoint Node or NodeList Name + +Fan:ConstantVolume, + Const Spd Fan 2, !- Name + Always On Discrete, !- Availability Schedule Name + 0.85, !- Fan Total Efficiency + 346, !- Pressure Rise Pa + 138.49, !- Maximum Flow Rate m3/s + 0.9, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + Node Air Deck Heating 2, !- Air Inlet Node Name + Node Air Deck Supply 2, !- Air Outlet Node Name + ; !- End-Use Subcategory + + +SetpointManager:Scheduled, + Setpoint Manager Scheduled Air Duck 2, !- Name + Temperature, !- Control Variable + Deck_Temperature 2, !- Schedule Name + Node Air Deck Supply 2; !- Setpoint Node or NodeList Name + +Controller:MechanicalVentilation, + Controller Mechanical Ventilation 3, !- Name + Always On Discrete, !- Availability Schedule Name + No, !- Demand Controlled Ventilation + ZoneSum, !- System Outdoor Air Method + , !- Zone Maximum Outdoor Air Fraction {dimensionless} + Thermal Zone 8, !- Zone or ZoneList Name 1 + Ventilation 8, !- Design Specification Outdoor Air Object Name 1 + , !- Design Specification Zone Air Distribution Object Name 1 + Thermal Zone 9, !- Zone or ZoneList Name 2 + Ventilation 9, !- Design Specification Outdoor Air Object Name 2 + , !- Design Specification Zone Air Distribution Object Name 2 + Thermal Zone 10, !- Zone or ZoneList Name 3 + Ventilation 10, !- Design Specification Outdoor Air Object Name 3 + ; !- Design Specification Zone Air Distribution Object Name 3 + +! add the air supply temp for different ahu + + +Schedule:Day:Interval, + Deck_Temperature_Default 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.0; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Summer_Design_Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.0; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Winter_Design_Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 13.0; !- Value Until Time 1 + +Schedule:Week:Daily, + Deck_Temperature 3 Week Rule - Jan1-Dec31, !- Name + Deck_Temperature_Default 3, !- Sunday Schedule:Day Name + Deck_Temperature_Default 3, !- Monday Schedule:Day Name + Deck_Temperature_Default 3, !- Tuesday Schedule:Day Name + Deck_Temperature_Default 3, !- Wednesday Schedule:Day Name + Deck_Temperature_Default 3, !- Thursday Schedule:Day Name + Deck_Temperature_Default 3, !- Friday Schedule:Day Name + Deck_Temperature_Default 3, !- Saturday Schedule:Day Name + Deck_Temperature_Default 3, !- Holiday Schedule:Day Name + Deck_Temperature_Summer_Design_Day 3, !- SummerDesignDay Schedule:Day Name + Deck_Temperature_Winter_Design_Day 3, !- WinterDesignDay Schedule:Day Name + Deck_Temperature_Default 3, !- CustomDay1 Schedule:Day Name + Deck_Temperature_Default 3; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Deck_Temperature 3, !- Name + Temperature 37, !- Schedule Type Limits Name + Deck_Temperature 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +AirLoopHVAC:SupplyPath, + Packaged Rooftop Air Conditioner 3 Node Air Supply 3 Supply Path, !- Name + Node Air Supply 3, !- Supply Air Path Inlet Node Name + AirLoopHVAC:ZoneSplitter, !- Component Object Type 1 + Air Loop HVAC Zone Splitter 3; !- Component Name 1 + +AirLoopHVAC:ZoneSplitter, + Air Loop HVAC Zone Splitter 3, !- Name + Node Air Supply 3, !- Inlet Node Name + Node Air Thermal Zone 8 Terminal, !- Outlet Node Name 1 + Node Air Thermal Zone 9 Terminal, !- Outlet Node Name 2 + Node Air Thermal Zone 10 Terminal; !- Outlet Node Name 3 + +AirLoopHVAC:ReturnPath, + Packaged Rooftop Air Conditioner 3 Return Path, !- Name + Node Air Return 3, !- Return Air Path Outlet Node Name + AirLoopHVAC:ZoneMixer, !- Component Object Type 1 + Air Loop HVAC Zone Mixer 3; !- Component Name 1 + +AirLoopHVAC:ZoneMixer, + Air Loop HVAC Zone Mixer 3, !- Name + Node Air Return 3, !- Outlet Node Name + Node Air Thermal Zone 8 Out, !- Inlet Node Name 1 + Node Air Thermal Zone 9 Out, !- Inlet Node Name 2 + Node Air Thermal Zone 10 Out; !- Inlet Node Name 3 + +! AHU loop 3, + +AirLoopHVAC, + Packaged Rooftop Air Conditioner 3, !- Name + , !- Controller List Name + Packaged Rooftop Air Conditioner 3Availability Manager List, !- Availability Manager List Name + AutoSize, !- Design Supply Air Flow Rate m3/s + Packaged Rooftop Air Conditioner 3 Supply Branches, !- Branch List Name + , !- Connector List Name + Node Air Deck Return 3, !- Supply Side Inlet Node Name + Node Air Return 3, !- Demand Side Outlet Node Name + Packaged Rooftop Air Conditioner 3 Demand Inlet Nodes, !- Demand Side Inlet Node Names + Packaged Rooftop Air Conditioner 3 Supply Outlet Nodes, !- Supply Side Outlet Node Names + 1; !- Design Return Air Flow Fraction of Supply Air Flow + +NodeList, + Packaged Rooftop Air Conditioner 3 Supply Outlet Nodes, !- Name + Node Air Deck Supply 3; !- Node Name 1 + +NodeList, + Packaged Rooftop Air Conditioner 3 Demand Inlet Nodes, !- Name + Node Air Supply 3; !- Node Name 1 + +Sizing:System, + Packaged Rooftop Air Conditioner 3, !- AirLoop Name + Sensible, !- Type of Load to Size On + Autosize, !- Design Outdoor Air Flow Rate m3/s + 0.3, !- Central Heating Maximum System Air Flow Ratio + 7, !- Preheat Design Temperature C + 0.008, !- Preheat Design Humidity Ratio kgWater/kgDryAir + 12.8, !- Precool Design Temperature C + 0.008, !- Precool Design Humidity Ratio kgWater/kgDryAir + 13.0, !- Central Cooling Design Supply Air Temperature C + 54.4, !- Central Heating Design Supply Air Temperature C + NonCoincident, !- Type of Zone Sum to Use + Yes, !- 100% Outdoor Air in Cooling + Yes, !- 100% Outdoor Air in Heating + 0.0085, !- Central Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Central Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + DesignDay, !- Cooling Supply Air Flow Rate Method + 0, !- Cooling Supply Air Flow Rate m3/s + 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate + 3.9475456e-05, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity m3/s-W + DesignDay, !- Heating Supply Air Flow Rate Method + 0, !- Heating Supply Air Flow Rate m3/s + 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate + 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate + 3.1588213e-05, !- Heating Supply Air Flow Rate Per Unit Heating Capacity m3/s-W + ZoneSum, !- System Outdoor Air Method + 1, !- Zone Maximum Outdoor Air Fraction dimensionless + CoolingDesignCapacity, !- Cooling Design Capacity Method + Autosize, !- Cooling Design Capacity W + 234.7, !- Cooling Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Cooling Design Capacity + HeatingDesignCapacity, !- Heating Design Capacity Method + Autosize, !- Heating Design Capacity W + 157, !- Heating Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Heating Design Capacity + OnOff, !- Central Cooling Capacity Control Method + Autosize; !- Occupant Diversity + +AvailabilityManagerAssignmentList, + Packaged Rooftop Air Conditioner 3Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Packaged Rooftop Air Conditioner 3 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Packaged Rooftop Air Conditioner 3 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +BranchList, + Packaged Rooftop Air Conditioner 3 Supply Branches, !- Name + Packaged Rooftop Air Conditioner 3 Main Branch; !- Branch Name 1 + +Branch, + Packaged Rooftop Air Conditioner 3 Main Branch, !- Name + , !- Pressure Drop Curve Name + AirLoopHVAC:OutdoorAirSystem, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 3, !- Component Name 1 + Node Air Deck Return 3, !- Component Inlet Node Name 1 + Node Air Deck Mixed 3, !- Component Outlet Node Name 1 + CoilSystem:Cooling:DX, !- Component Object Type 2 + 1 Spd DX Clg Coil 3 CoilSystem, !- Component Name 2 + Node Air Deck Mixed 3, !- Component Inlet Node Name 2 + Node Air Deck Cooling 3, !- Component Outlet Node Name 2 + Coil:Heating:Fuel, !- Component Object Type 3 + Gas Htg Coil 3, !- Component Name 3 + Node Air Deck Cooling 3, !- Component Inlet Node Name 3 + Node Air Deck Heating 3, !- Component Outlet Node Name 3 + Fan:ConstantVolume, !- Component Object Type 4 + Const Spd Fan 3, !- Component Name 4 + Node Air Deck Heating 3, !- Component Inlet Node Name 4 + Node Air Deck Supply 3; !- Component Outlet Node Name 4 + +AirLoopHVAC:OutdoorAirSystem, + Air Loop HVAC Outdoor Air System 3, !- Name + Air Loop HVAC Outdoor Air System 3 Controller List, !- Controller List Name + Air Loop HVAC Outdoor Air System 3 Equipment List; !- Outdoor Air Equipment List Name + +AirLoopHVAC:ControllerList, + Air Loop HVAC Outdoor Air System 3 Controller List, !- Name + Controller:OutdoorAir, !- Controller Object Type 1 + Controller Outdoor Air 3; !- Controller Name 1 + +Controller:OutdoorAir, + Controller Outdoor Air 3, !- Name + Node Air Deck Exhaust 3, !- Relief Air Outlet Node Name + Node Air Deck Return 3, !- Return Air Node Name + Node Air Deck Mixed 3, !- Mixed Air Node Name + Node Air Deck Fresh 3, !- Actuator Node Name + 0, !- Minimum Outdoor Air Flow Rate m3/s + Autosize, !- Maximum Outdoor Air Flow Rate m3/s + DifferentialDryBulb, !- Economizer Control Type + ModulateFlow, !- Economizer Control Action Type + 28, !- Economizer Maximum Limit Dry-Bulb Temperature C + 64000, !- Economizer Maximum Limit Enthalpy J/kg + , !- Economizer Maximum Limit Dewpoint Temperature C + , !- Electronic Enthalpy Limit Curve Name + -100, !- Economizer Minimum Limit Dry-Bulb Temperature C + NoLockout, !- Lockout Type + FixedMinimum, !- Minimum Limit Type + , !- Minimum Outdoor Air Schedule Name + , !- Minimum Fraction of Outdoor Air Schedule Name + , !- Maximum Fraction of Outdoor Air Schedule Name + Controller Mechanical Ventilation 3, !- Mechanical Ventilation Controller Name + , !- Time of Day Economizer Control Schedule Name + No, !- High Humidity Control + , !- Humidistat Control Zone Name + , !- High Humidity Outdoor Air Flow Ratio + Yes, !- Control High Indoor Humidity Based on Outdoor Humidity Ratio + BypassWhenWithinEconomizerLimits; !- Heat Recovery Bypass Control Type + +AvailabilityManagerAssignmentList, + Air Loop HVAC Outdoor Air System 3 Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Air Loop HVAC Outdoor Air System 3 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Air Loop HVAC Outdoor Air System 3 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +OutdoorAir:NodeList, + Node Air Deck Fresh 3; !- Node or NodeList Name 1 + +AirLoopHVAC:OutdoorAirSystem:EquipmentList, + Air Loop HVAC Outdoor Air System 3 Equipment List, !- Name + OutdoorAir:Mixer, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 3 Outdoor Air Mixer; !- Component Name 1 + +OutdoorAir:Mixer, + Air Loop HVAC Outdoor Air System 3 Outdoor Air Mixer, !- Name + Node Air Deck Mixed 3, !- Mixed Air Node Name + Node Air Deck Fresh 3, !- Outdoor Air Stream Node Name + Node Air Deck Exhaust 3, !- Relief Air Stream Node Name + Node Air Deck Return 3; !- Return Air Stream Node Name + +SetpointManager:MixedAir, + Node Air Deck Mixed 3 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 3, !- Reference Setpoint Node Name + Node Air Deck Heating 3, !- Fan Inlet Node Name + Node Air Deck Supply 3, !- Fan Outlet Node Name + Node Air Deck Mixed 3; !- Setpoint Node or NodeList Name + +CoilSystem:Cooling:DX, + 1 Spd DX Clg Coil 3 CoilSystem, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Node Air Deck Mixed 3, !- DX Cooling Coil System Inlet Node Name + Node Air Deck Cooling 3, !- DX Cooling Coil System Outlet Node Name + Node Air Deck Cooling 3, !- DX Cooling Coil System Sensor Node Name + Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type + 1 Spd DX Clg Coil 3; !- Cooling Coil Name + +SetpointManager:MixedAir, + Node Air Deck Cooling 3 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 3, !- Reference Setpoint Node Name + Node Air Deck Heating 3, !- Fan Inlet Node Name + Node Air Deck Supply 3, !- Fan Outlet Node Name + Node Air Deck Cooling 3; !- Setpoint Node or NodeList Name + +Coil:Cooling:DX:SingleSpeed, + 1 Spd DX Clg Coil 3, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + 4.22, !- Gross Rated Cooling COP W/W + Autosize, !- Rated Air Flow Rate m3/s + 773.3, !- Rated Evaporator Fan Power Per Volume Flow Rate W/(m3/s) + Node Air Deck Mixed 3, !- Air Inlet Node Name + Node Air Deck Cooling 3, !- Air Outlet Node Name + OS:Curve:Biquadratic 1, !- Total Cooling Capacity Function of Temperature Curve Name + OS:Curve:Quadratic 1, !- Total Cooling Capacity Function of Flow Fraction Curve Name + OS:Curve:Biquadratic 2, !- Energy Input Ratio Function of Temperature Curve Name + OS:Curve:Quadratic 2, !- Energy Input Ratio Function of Flow Fraction Curve Name + OS:Curve:Quadratic 3, !- Part Load Fraction Correlation Curve Name + -25, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation C + , !- Nominal Time for Condensate Removal to Begin s + , !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity + , !- Maximum Cycling Rate cycles/hr + , !- Latent Capacity Time Constant s + , !- Condenser Air Inlet Node Name + AirCooled, !- Condenser Type + 0, !- Evaporative Condenser Effectiveness + Autosize, !- Evaporative Condenser Air Flow Rate m3/s + Autosize, !- Evaporative Condenser Pump Rated Power Consumption W + 0, !- Crankcase Heater Capacity W + 0, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation C + , !- Supply Water Storage Tank Name + , !- Condensate Collection Water Storage Tank Name + 0, !- Basin Heater Capacity W/K + 10; !- Basin Heater Setpoint Temperature C + +Coil:Heating:Fuel, + Gas Htg Coil 3, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + NaturalGas, !- Fuel Type + 0.72, !- Burner Efficiency + Autosize, !- Nominal Capacity W + Node Air Deck Cooling 3, !- Air Inlet Node Name + Node Air Deck Heating 3, !- Air Outlet Node Name + Node Air Deck Heating 3, !- Temperature Setpoint Node Name + 0, !- Parasitic Electric Load W + , !- Part Load Fraction Correlation Curve Name + 0; !- Parasitic Fuel Load W + +SetpointManager:MixedAir, + Node Air Deck Heating 3 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 3, !- Reference Setpoint Node Name + Node Air Deck Heating 3, !- Fan Inlet Node Name + Node Air Deck Supply 3, !- Fan Outlet Node Name + Node Air Deck Heating 3; !- Setpoint Node or NodeList Name + +Fan:ConstantVolume, + Const Spd Fan 3, !- Name + Always On Discrete, !- Availability Schedule Name + 0.87, !- Fan Total Efficiency + 1707, !- Pressure Rise Pa + 89.2, !- Maximum Flow Rate m3/s + 0.9, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + Node Air Deck Heating 3, !- Air Inlet Node Name + Node Air Deck Supply 3, !- Air Outlet Node Name + ; !- End-Use Subcategory + + +SetpointManager:Scheduled, + Setpoint Manager Scheduled Air Duck 3, !- Name + Temperature, !- Control Variable + Deck_Temperature 3, !- Schedule Name + Node Air Deck Supply 3; !- Setpoint Node or NodeList Name + +Controller:MechanicalVentilation, + Controller Mechanical Ventilation 4, !- Name + Always On Discrete, !- Availability Schedule Name + No, !- Demand Controlled Ventilation + ZoneSum, !- System Outdoor Air Method + , !- Zone Maximum Outdoor Air Fraction {dimensionless} + Thermal Zone 11, !- Zone or ZoneList Name 1 + Ventilation 11, !- Design Specification Outdoor Air Object Name 1 + , !- Design Specification Zone Air Distribution Object Name 1 + Thermal Zone 12, !- Zone or ZoneList Name 2 + Ventilation 12, !- Design Specification Outdoor Air Object Name 2 + ; !- Design Specification Zone Air Distribution Object Name 2 + +! add the air supply temp for different ahu + + +Schedule:Day:Interval, + Deck_Temperature_Default 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.2; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Summer_Design_Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.2; !- Value Until Time 1 + +Schedule:Day:Interval, + Deck_Temperature_Winter_Design_Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 18.2; !- Value Until Time 1 + +Schedule:Week:Daily, + Deck_Temperature 4 Week Rule - Jan1-Dec31, !- Name + Deck_Temperature_Default 4, !- Sunday Schedule:Day Name + Deck_Temperature_Default 4, !- Monday Schedule:Day Name + Deck_Temperature_Default 4, !- Tuesday Schedule:Day Name + Deck_Temperature_Default 4, !- Wednesday Schedule:Day Name + Deck_Temperature_Default 4, !- Thursday Schedule:Day Name + Deck_Temperature_Default 4, !- Friday Schedule:Day Name + Deck_Temperature_Default 4, !- Saturday Schedule:Day Name + Deck_Temperature_Default 4, !- Holiday Schedule:Day Name + Deck_Temperature_Summer_Design_Day 4, !- SummerDesignDay Schedule:Day Name + Deck_Temperature_Winter_Design_Day 4, !- WinterDesignDay Schedule:Day Name + Deck_Temperature_Default 4, !- CustomDay1 Schedule:Day Name + Deck_Temperature_Default 4; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Deck_Temperature 4, !- Name + Temperature 37, !- Schedule Type Limits Name + Deck_Temperature 4 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +AirLoopHVAC:SupplyPath, + Packaged Rooftop Air Conditioner 4 Node Air Supply 4 Supply Path, !- Name + Node Air Supply 4, !- Supply Air Path Inlet Node Name + AirLoopHVAC:ZoneSplitter, !- Component Object Type 1 + Air Loop HVAC Zone Splitter 4; !- Component Name 1 + +AirLoopHVAC:ZoneSplitter, + Air Loop HVAC Zone Splitter 4, !- Name + Node Air Supply 4, !- Inlet Node Name + Node Air Thermal Zone 11 Terminal, !- Outlet Node Name 1 + Node Air Thermal Zone 12 Terminal; !- Outlet Node Name 2 + +AirLoopHVAC:ReturnPath, + Packaged Rooftop Air Conditioner 4 Return Path, !- Name + Node Air Return 4, !- Return Air Path Outlet Node Name + AirLoopHVAC:ZoneMixer, !- Component Object Type 1 + Air Loop HVAC Zone Mixer 4; !- Component Name 1 + +AirLoopHVAC:ZoneMixer, + Air Loop HVAC Zone Mixer 4, !- Name + Node Air Return 4, !- Outlet Node Name + Node Air Thermal Zone 11 Out, !- Inlet Node Name 1 + Node Air Thermal Zone 12 Out; !- Inlet Node Name 2 + +! AHU loop 4, + +AirLoopHVAC, + Packaged Rooftop Air Conditioner 4, !- Name + , !- Controller List Name + Packaged Rooftop Air Conditioner 4Availability Manager List, !- Availability Manager List Name + AutoSize, !- Design Supply Air Flow Rate m3/s + Packaged Rooftop Air Conditioner 4 Supply Branches, !- Branch List Name + , !- Connector List Name + Node Air Deck Return 4, !- Supply Side Inlet Node Name + Node Air Return 4, !- Demand Side Outlet Node Name + Packaged Rooftop Air Conditioner 4 Demand Inlet Nodes, !- Demand Side Inlet Node Names + Packaged Rooftop Air Conditioner 4 Supply Outlet Nodes, !- Supply Side Outlet Node Names + 1; !- Design Return Air Flow Fraction of Supply Air Flow + +NodeList, + Packaged Rooftop Air Conditioner 4 Supply Outlet Nodes, !- Name + Node Air Deck Supply 4; !- Node Name 1 + +NodeList, + Packaged Rooftop Air Conditioner 4 Demand Inlet Nodes, !- Name + Node Air Supply 4; !- Node Name 1 + +Sizing:System, + Packaged Rooftop Air Conditioner 4, !- AirLoop Name + Sensible, !- Type of Load to Size On + Autosize, !- Design Outdoor Air Flow Rate m3/s + 0.3, !- Central Heating Maximum System Air Flow Ratio + 7, !- Preheat Design Temperature C + 0.008, !- Preheat Design Humidity Ratio kgWater/kgDryAir + 12.8, !- Precool Design Temperature C + 0.008, !- Precool Design Humidity Ratio kgWater/kgDryAir + 18.2, !- Central Cooling Design Supply Air Temperature C + 42.2, !- Central Heating Design Supply Air Temperature C + NonCoincident, !- Type of Zone Sum to Use + Yes, !- 100% Outdoor Air in Cooling + Yes, !- 100% Outdoor Air in Heating + 0.0085, !- Central Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Central Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + DesignDay, !- Cooling Supply Air Flow Rate Method + 0, !- Cooling Supply Air Flow Rate m3/s + 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate + 3.9475456e-05, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity m3/s-W + DesignDay, !- Heating Supply Air Flow Rate Method + 0, !- Heating Supply Air Flow Rate m3/s + 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area m3/s-m2 + 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate + 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate + 3.1588213e-05, !- Heating Supply Air Flow Rate Per Unit Heating Capacity m3/s-W + ZoneSum, !- System Outdoor Air Method + 1, !- Zone Maximum Outdoor Air Fraction dimensionless + CoolingDesignCapacity, !- Cooling Design Capacity Method + Autosize, !- Cooling Design Capacity W + 234.7, !- Cooling Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Cooling Design Capacity + HeatingDesignCapacity, !- Heating Design Capacity Method + Autosize, !- Heating Design Capacity W + 157, !- Heating Design Capacity Per Floor Area W/m2 + 1, !- Fraction of Autosized Heating Design Capacity + OnOff, !- Central Cooling Capacity Control Method + Autosize; !- Occupant Diversity + +AvailabilityManagerAssignmentList, + Packaged Rooftop Air Conditioner 4Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Packaged Rooftop Air Conditioner 4 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Packaged Rooftop Air Conditioner 4 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +BranchList, + Packaged Rooftop Air Conditioner 4 Supply Branches, !- Name + Packaged Rooftop Air Conditioner 4 Main Branch; !- Branch Name 1 + +Branch, + Packaged Rooftop Air Conditioner 4 Main Branch, !- Name + , !- Pressure Drop Curve Name + AirLoopHVAC:OutdoorAirSystem, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 4, !- Component Name 1 + Node Air Deck Return 4, !- Component Inlet Node Name 1 + Node Air Deck Mixed 4, !- Component Outlet Node Name 1 + CoilSystem:Cooling:DX, !- Component Object Type 2 + 1 Spd DX Clg Coil 4 CoilSystem, !- Component Name 2 + Node Air Deck Mixed 4, !- Component Inlet Node Name 2 + Node Air Deck Cooling 4, !- Component Outlet Node Name 2 + Coil:Heating:Fuel, !- Component Object Type 3 + Gas Htg Coil 4, !- Component Name 3 + Node Air Deck Cooling 4, !- Component Inlet Node Name 3 + Node Air Deck Heating 4, !- Component Outlet Node Name 3 + Fan:ConstantVolume, !- Component Object Type 4 + Const Spd Fan 4, !- Component Name 4 + Node Air Deck Heating 4, !- Component Inlet Node Name 4 + Node Air Deck Supply 4; !- Component Outlet Node Name 4 + +AirLoopHVAC:OutdoorAirSystem, + Air Loop HVAC Outdoor Air System 4, !- Name + Air Loop HVAC Outdoor Air System 4 Controller List, !- Controller List Name + Air Loop HVAC Outdoor Air System 4 Equipment List; !- Outdoor Air Equipment List Name + +AirLoopHVAC:ControllerList, + Air Loop HVAC Outdoor Air System 4 Controller List, !- Name + Controller:OutdoorAir, !- Controller Object Type 1 + Controller Outdoor Air 4; !- Controller Name 1 + +Controller:OutdoorAir, + Controller Outdoor Air 4, !- Name + Node Air Deck Exhaust 4, !- Relief Air Outlet Node Name + Node Air Deck Return 4, !- Return Air Node Name + Node Air Deck Mixed 4, !- Mixed Air Node Name + Node Air Deck Fresh 4, !- Actuator Node Name + 0, !- Minimum Outdoor Air Flow Rate m3/s + Autosize, !- Maximum Outdoor Air Flow Rate m3/s + NoEconomizer, !- Economizer Control Type + ModulateFlow, !- Economizer Control Action Type + 28, !- Economizer Maximum Limit Dry-Bulb Temperature C + 64000, !- Economizer Maximum Limit Enthalpy J/kg + , !- Economizer Maximum Limit Dewpoint Temperature C + , !- Electronic Enthalpy Limit Curve Name + -100, !- Economizer Minimum Limit Dry-Bulb Temperature C + NoLockout, !- Lockout Type + FixedMinimum, !- Minimum Limit Type + , !- Minimum Outdoor Air Schedule Name + , !- Minimum Fraction of Outdoor Air Schedule Name + , !- Maximum Fraction of Outdoor Air Schedule Name + Controller Mechanical Ventilation 4, !- Mechanical Ventilation Controller Name + , !- Time of Day Economizer Control Schedule Name + No, !- High Humidity Control + , !- Humidistat Control Zone Name + , !- High Humidity Outdoor Air Flow Ratio + Yes, !- Control High Indoor Humidity Based on Outdoor Humidity Ratio + BypassWhenWithinEconomizerLimits; !- Heat Recovery Bypass Control Type + +AvailabilityManagerAssignmentList, + Air Loop HVAC Outdoor Air System 4 Availability Manager List, !- Name + AvailabilityManager:Scheduled, !- Availability Manager Object Type 1 + Air Loop HVAC Outdoor Air System 4 Availability Manager; !- Availability Manager Name 1 + +AvailabilityManager:Scheduled, + Air Loop HVAC Outdoor Air System 4 Availability Manager, !- Name + Always On Discrete; !- Schedule Name + +OutdoorAir:NodeList, + Node Air Deck Fresh 4; !- Node or NodeList Name 1 + +AirLoopHVAC:OutdoorAirSystem:EquipmentList, + Air Loop HVAC Outdoor Air System 4 Equipment List, !- Name + OutdoorAir:Mixer, !- Component Object Type 1 + Air Loop HVAC Outdoor Air System 4 Outdoor Air Mixer; !- Component Name 1 + +OutdoorAir:Mixer, + Air Loop HVAC Outdoor Air System 4 Outdoor Air Mixer, !- Name + Node Air Deck Mixed 4, !- Mixed Air Node Name + Node Air Deck Fresh 4, !- Outdoor Air Stream Node Name + Node Air Deck Exhaust 4, !- Relief Air Stream Node Name + Node Air Deck Return 4; !- Return Air Stream Node Name + +SetpointManager:MixedAir, + Node Air Deck Mixed 4 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 4, !- Reference Setpoint Node Name + Node Air Deck Heating 4, !- Fan Inlet Node Name + Node Air Deck Supply 4, !- Fan Outlet Node Name + Node Air Deck Mixed 4; !- Setpoint Node or NodeList Name + +CoilSystem:Cooling:DX, + 1 Spd DX Clg Coil 4 CoilSystem, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Node Air Deck Mixed 4, !- DX Cooling Coil System Inlet Node Name + Node Air Deck Cooling 4, !- DX Cooling Coil System Outlet Node Name + Node Air Deck Cooling 4, !- DX Cooling Coil System Sensor Node Name + Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type + 1 Spd DX Clg Coil 4; !- Cooling Coil Name + +SetpointManager:MixedAir, + Node Air Deck Cooling 4 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 4, !- Reference Setpoint Node Name + Node Air Deck Heating 4, !- Fan Inlet Node Name + Node Air Deck Supply 4, !- Fan Outlet Node Name + Node Air Deck Cooling 4; !- Setpoint Node or NodeList Name + +Coil:Cooling:DX:SingleSpeed, + 1 Spd DX Clg Coil 4, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + 4.04, !- Gross Rated Cooling COP W/W + Autosize, !- Rated Air Flow Rate m3/s + 773.3, !- Rated Evaporator Fan Power Per Volume Flow Rate W/(m3/s) + Node Air Deck Mixed 4, !- Air Inlet Node Name + Node Air Deck Cooling 4, !- Air Outlet Node Name + OS:Curve:Biquadratic 1, !- Total Cooling Capacity Function of Temperature Curve Name + OS:Curve:Quadratic 1, !- Total Cooling Capacity Function of Flow Fraction Curve Name + OS:Curve:Biquadratic 2, !- Energy Input Ratio Function of Temperature Curve Name + OS:Curve:Quadratic 2, !- Energy Input Ratio Function of Flow Fraction Curve Name + OS:Curve:Quadratic 3, !- Part Load Fraction Correlation Curve Name + -25, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation C + , !- Nominal Time for Condensate Removal to Begin s + , !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity + , !- Maximum Cycling Rate cycles/hr + , !- Latent Capacity Time Constant s + , !- Condenser Air Inlet Node Name + AirCooled, !- Condenser Type + 0, !- Evaporative Condenser Effectiveness + Autosize, !- Evaporative Condenser Air Flow Rate m3/s + Autosize, !- Evaporative Condenser Pump Rated Power Consumption W + 0, !- Crankcase Heater Capacity W + 0, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation C + , !- Supply Water Storage Tank Name + , !- Condensate Collection Water Storage Tank Name + 0, !- Basin Heater Capacity W/K + 10; !- Basin Heater Setpoint Temperature C + +Coil:Heating:Fuel, + Gas Htg Coil 4, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + NaturalGas, !- Fuel Type + 0.89, !- Burner Efficiency + Autosize, !- Nominal Capacity W + Node Air Deck Cooling 4, !- Air Inlet Node Name + Node Air Deck Heating 4, !- Air Outlet Node Name + Node Air Deck Heating 4, !- Temperature Setpoint Node Name + 0, !- Parasitic Electric Load W + , !- Part Load Fraction Correlation Curve Name + 0; !- Parasitic Fuel Load W + +SetpointManager:MixedAir, + Node Air Deck Heating 4 OS Default SPM, !- Name + Temperature, !- Control Variable + Node Air Deck Supply 4, !- Reference Setpoint Node Name + Node Air Deck Heating 4, !- Fan Inlet Node Name + Node Air Deck Supply 4, !- Fan Outlet Node Name + Node Air Deck Heating 4; !- Setpoint Node or NodeList Name + +Fan:ConstantVolume, + Const Spd Fan 4, !- Name + Always On Discrete, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1668, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.9, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + Node Air Deck Heating 4, !- Air Inlet Node Name + Node Air Deck Supply 4, !- Air Outlet Node Name + ; !- End-Use Subcategory + + +SetpointManager:Scheduled, + Setpoint Manager Scheduled Air Duck 4, !- Name + Temperature, !- Control Variable + Deck_Temperature 4, !- Schedule Name + Node Air Deck Supply 4; !- Setpoint Node or NodeList Name + +ZoneControl:Thermostat, + Thermal Zone 1 Thermostat, !- Name + Thermal Zone 1, !- Zone or ZoneList Name + Thermal Zone 1 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 1, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 1 Thermostat Schedule, !- Name + Thermal Zone 1 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 1 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 1, !- Name + HtgSetp 1, !- Heating Setpoint Temperature Schedule Name + ClgSetp 1; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 1, !- Zone Name + Thermal Zone 1 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 1 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 1, !- Zone Air Node Name + Thermal Zone 1 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 1 Inlet Node List, !- Name + Node Air Thermal Zone 1 In; !- Node Name 1 + +NodeList, + Thermal Zone 1 Return Node List, !- Name + Node Air Thermal Zone 1 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 1, !- Name + Node Air Thermal Zone 1 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 1; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 1, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 1 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 1 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 1 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 1, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 1, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.5, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 1, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 1, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 2 Thermostat, !- Name + Thermal Zone 2, !- Zone or ZoneList Name + Thermal Zone 2 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 2, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 2 Thermostat Schedule, !- Name + Thermal Zone 2 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 2 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 2, !- Name + HtgSetp 2, !- Heating Setpoint Temperature Schedule Name + ClgSetp 2; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 2, !- Zone Name + Thermal Zone 2 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 2 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 2, !- Zone Air Node Name + Thermal Zone 2 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 2 Inlet Node List, !- Name + Node Air Thermal Zone 2 In; !- Node Name 1 + +NodeList, + Thermal Zone 2 Return Node List, !- Name + Node Air Thermal Zone 2 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 2, !- Name + Node Air Thermal Zone 2 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 2; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 2, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 2 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 2 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 2 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 2, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 2, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.5, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 2, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 2, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 3 Thermostat, !- Name + Thermal Zone 3, !- Zone or ZoneList Name + Thermal Zone 3 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 3, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 3 Thermostat Schedule, !- Name + Thermal Zone 3 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 3 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 3, !- Name + HtgSetp 3, !- Heating Setpoint Temperature Schedule Name + ClgSetp 3; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 3, !- Zone Name + Thermal Zone 3 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 3 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 3, !- Zone Air Node Name + Thermal Zone 3 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 3 Inlet Node List, !- Name + Node Air Thermal Zone 3 In; !- Node Name 1 + +NodeList, + Thermal Zone 3 Return Node List, !- Name + Node Air Thermal Zone 3 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 3, !- Name + Node Air Thermal Zone 3 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 3; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 3, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 3 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 3 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 3 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 3, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 3, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.5, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 3, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 3, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 4 Thermostat, !- Name + Thermal Zone 4, !- Zone or ZoneList Name + Thermal Zone 4 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 4, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 4 Thermostat Schedule, !- Name + Thermal Zone 4 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 4 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 4, !- Name + HtgSetp 4, !- Heating Setpoint Temperature Schedule Name + ClgSetp 4; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 4, !- Zone Name + Thermal Zone 4 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 4 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 4, !- Zone Air Node Name + Thermal Zone 4 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 4 Inlet Node List, !- Name + Node Air Thermal Zone 4 In; !- Node Name 1 + +NodeList, + Thermal Zone 4 Return Node List, !- Name + Node Air Thermal Zone 4 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 4, !- Name + Node Air Thermal Zone 4 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 4; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 4, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 4 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 4 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 4 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 4, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 4, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.5, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 4, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 4, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 5 Thermostat, !- Name + Thermal Zone 5, !- Zone or ZoneList Name + Thermal Zone 5 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 5, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 5 Thermostat Schedule, !- Name + Thermal Zone 5 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 5 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 5, !- Name + HtgSetp 5, !- Heating Setpoint Temperature Schedule Name + ClgSetp 5; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 5, !- Zone Name + Thermal Zone 5 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 5 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 5, !- Zone Air Node Name + Thermal Zone 5 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 5 Inlet Node List, !- Name + Node Air Thermal Zone 5 In; !- Node Name 1 + +NodeList, + Thermal Zone 5 Return Node List, !- Name + Node Air Thermal Zone 5 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 5, !- Name + Node Air Thermal Zone 5 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 5; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 5, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 5 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 5 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 5 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 5, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 5, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 18.7, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 41.9, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 5, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 5, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 6 Thermostat, !- Name + Thermal Zone 6, !- Zone or ZoneList Name + Thermal Zone 6 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 6, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 6 Thermostat Schedule, !- Name + Thermal Zone 6 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 6 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 6, !- Name + HtgSetp 6, !- Heating Setpoint Temperature Schedule Name + ClgSetp 6; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 6, !- Zone Name + Thermal Zone 6 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 6 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 6, !- Zone Air Node Name + Thermal Zone 6 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 6 Inlet Node List, !- Name + Node Air Thermal Zone 6 In; !- Node Name 1 + +NodeList, + Thermal Zone 6 Return Node List, !- Name + Node Air Thermal Zone 6 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 6, !- Name + Node Air Thermal Zone 6 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 6; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 6, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 6 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 6 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 6 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 6, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 6, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 18.7, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 41.9, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 6, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 6, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 7 Thermostat, !- Name + Thermal Zone 7, !- Zone or ZoneList Name + Thermal Zone 7 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 7, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 7 Thermostat Schedule, !- Name + Thermal Zone 7 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 7 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 7, !- Name + HtgSetp 7, !- Heating Setpoint Temperature Schedule Name + ClgSetp 7; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 7, !- Zone Name + Thermal Zone 7 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 7 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 7, !- Zone Air Node Name + Thermal Zone 7 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 7 Inlet Node List, !- Name + Node Air Thermal Zone 7 In; !- Node Name 1 + +NodeList, + Thermal Zone 7 Return Node List, !- Name + Node Air Thermal Zone 7 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 7, !- Name + Node Air Thermal Zone 7 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 7; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 7, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 7 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 7 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 7 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 7, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 7, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 18.7, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 41.9, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 7, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 7, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 8 Thermostat, !- Name + Thermal Zone 8, !- Zone or ZoneList Name + Thermal Zone 8 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 8, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 8 Thermostat Schedule, !- Name + Thermal Zone 8 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 8 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 8, !- Name + HtgSetp 8, !- Heating Setpoint Temperature Schedule Name + ClgSetp 8; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 8, !- Zone Name + Thermal Zone 8 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 8 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 8, !- Zone Air Node Name + Thermal Zone 8 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 8 Inlet Node List, !- Name + Node Air Thermal Zone 8 In; !- Node Name 1 + +NodeList, + Thermal Zone 8 Return Node List, !- Name + Node Air Thermal Zone 8 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 8, !- Name + Node Air Thermal Zone 8 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 8; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 8, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 8 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 8 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 8 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 8, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 8, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.0, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 54.4, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 8, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 8, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 9 Thermostat, !- Name + Thermal Zone 9, !- Zone or ZoneList Name + Thermal Zone 9 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 9, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 9 Thermostat Schedule, !- Name + Thermal Zone 9 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 9 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 9, !- Name + HtgSetp 9, !- Heating Setpoint Temperature Schedule Name + ClgSetp 9; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 9, !- Zone Name + Thermal Zone 9 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 9 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 9, !- Zone Air Node Name + Thermal Zone 9 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 9 Inlet Node List, !- Name + Node Air Thermal Zone 9 In; !- Node Name 1 + +NodeList, + Thermal Zone 9 Return Node List, !- Name + Node Air Thermal Zone 9 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 9, !- Name + Node Air Thermal Zone 9 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 9; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 9, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 9 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 9 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 9 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 9, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 9, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.0, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 54.4, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 9, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 9, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 10 Thermostat, !- Name + Thermal Zone 10, !- Zone or ZoneList Name + Thermal Zone 10 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 10, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 10 Thermostat Schedule, !- Name + Thermal Zone 10 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 10 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 10, !- Name + HtgSetp 10, !- Heating Setpoint Temperature Schedule Name + ClgSetp 10; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 10, !- Zone Name + Thermal Zone 10 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 10 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 10, !- Zone Air Node Name + Thermal Zone 10 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 10 Inlet Node List, !- Name + Node Air Thermal Zone 10 In; !- Node Name 1 + +NodeList, + Thermal Zone 10 Return Node List, !- Name + Node Air Thermal Zone 10 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 10, !- Name + Node Air Thermal Zone 10 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 10; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 10, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 10 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 10 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 10 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 10, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 10, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.0, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 54.4, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 10, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 10, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 11 Thermostat, !- Name + Thermal Zone 11, !- Zone or ZoneList Name + Thermal Zone 11 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 11, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 11 Thermostat Schedule, !- Name + Thermal Zone 11 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 11 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 11, !- Name + HtgSetp 11, !- Heating Setpoint Temperature Schedule Name + ClgSetp 11; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 11, !- Zone Name + Thermal Zone 11 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 11 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 11, !- Zone Air Node Name + Thermal Zone 11 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 11 Inlet Node List, !- Name + Node Air Thermal Zone 11 In; !- Node Name 1 + +NodeList, + Thermal Zone 11 Return Node List, !- Name + Node Air Thermal Zone 11 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 11, !- Name + Node Air Thermal Zone 11 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 11; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 11, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 11 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 11 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 11 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 11, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 11, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 18.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 42.2, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 11, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 11, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 12 Thermostat, !- Name + Thermal Zone 12, !- Zone or ZoneList Name + Thermal Zone 12 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 12, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 12 Thermostat Schedule, !- Name + Thermal Zone 12 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 12 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 12, !- Name + HtgSetp 12, !- Heating Setpoint Temperature Schedule Name + ClgSetp 12; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 12, !- Zone Name + Thermal Zone 12 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 12 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + , !- Zone Air Exhaust Node or NodeList Name + Node 12, !- Zone Air Node Name + Thermal Zone 12 Return Node List; !- Zone Return Air Node or NodeList Name + +NodeList, + Thermal Zone 12 Inlet Node List, !- Name + Node Air Thermal Zone 12 In; !- Node Name 1 + +NodeList, + Thermal Zone 12 Return Node List, !- Name + Node Air Thermal Zone 12 Out; !- Node Name 1 + +ZoneHVAC:AirDistributionUnit, + ADU Air Terminal Single Duct Constant Volume No Reheat 12, !- Name + Node Air Thermal Zone 12 In, !- Air Distribution Unit Outlet Node Name + AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type + Air Terminal Single Duct Constant Volume No Reheat 12; !- Air Terminal Name + +AirTerminal:SingleDuct:ConstantVolume:NoReheat, + Air Terminal Single Duct Constant Volume No Reheat 12, !- Name + Always On Discrete, !- Availability Schedule Name + Node Air Thermal Zone 12 Terminal, !- Air Inlet Node Name + Node Air Thermal Zone 12 In, !- Air Outlet Node Name + AutoSize; !- Maximum Air Flow Rate m3/s + +ZoneHVAC:EquipmentList, + Thermal Zone 12 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:AirDistributionUnit, !- Zone Equipment Object Type + ADU Air Terminal Single Duct Constant Volume No Reheat 12, !- Zone Equipment Name + 1, !- Zone Equipment Cooling Sequence + 1, !- Zone Equipment Heating or No-Load Sequence + , !- Zone Equipment Sequential Cooling Fraction Schedule Name + ; !- Zone Equipment Sequential Heating Fraction Schedule Name + +Sizing:Zone, + Thermal Zone 12, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 18.2, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 42.2, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 12, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 12, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 3.29; !- Outdoor Air Flow Air Changes per Hour 1/hr + +Curve:Biquadratic, + OS:Curve:Biquadratic 1, !- Name + 0.42415, !- Coefficient1 Constant + 0.04426, !- Coefficient2 x + -0.00042, !- Coefficient3 x**2 + 0.00333, !- Coefficient4 y + -8e-05, !- Coefficient5 y**2 + -0.00021, !- Coefficient6 x*y + 17, !- Minimum Value of x + 22, !- Maximum Value of x + 13, !- Minimum Value of y + 46; !- Maximum Value of y + +Curve:Quadratic, + OS:Curve:Quadratic 1, !- Name + 0.77136, !- Coefficient1 Constant + 0.34053, !- Coefficient2 x + -0.11088, !- Coefficient3 x**2 + 0.75918, !- Minimum Value of x + 1.13877; !- Maximum Value of x + +Curve:Biquadratic, + OS:Curve:Biquadratic 2, !- Name + 1.23649, !- Coefficient1 Constant + -0.02431, !- Coefficient2 x + 0.00057, !- Coefficient3 x**2 + -0.01434, !- Coefficient4 y + 0.00063, !- Coefficient5 y**2 + -0.00038, !- Coefficient6 x*y + 17, !- Minimum Value of x + 22, !- Maximum Value of x + 13, !- Minimum Value of y + 46; !- Maximum Value of y + +Curve:Quadratic, + OS:Curve:Quadratic 2, !- Name + 1.2055, !- Coefficient1 Constant + -0.32953, !- Coefficient2 x + 0.12308, !- Coefficient3 x**2 + 0.75918, !- Minimum Value of x + 1.13877; !- Maximum Value of x + +Curve:Quadratic, + OS:Curve:Quadratic 3, !- Name + 0.771, !- Coefficient1 Constant + 0.229, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Minimum Value of x + 1; !- Maximum Value of x + +! ################################################################################# +! simulation setting +SimulationControl, + Yes, !- Do Zone Sizing Calculation + Yes, !- Do System Sizing Calculation + Yes, !- Do Plant Sizing Calculation + Yes, !- Run Simulation for Sizing Periods + Yes, !- Run Simulation for Weather File Run Periods + , !- Do HVAC Sizing Simulation for Sizing Periods + ; !- Maximum Number of HVAC Sizing Simulation Passes + +ConvergenceLimits, + 1; !- Minimum System Timestep + +HeatBalanceAlgorithm, + ConductionTransferFunction, !- Algorithm + 200; !- Surface Temperature Upper Limit + +RunPeriod, + Run Period 1, !- Name + 1, !- Begin Month + 1, !- Begin Day of Month + 2006, !- Begin Year + 12, !- End Month + 31, !- End Day of Month + 2006, !- End Year + Sunday, !- Day of Week for Start Day + No, !- Use Weather File Holidays and Special Days + No, !- Use Weather File Daylight Saving Period + No, !- Apply Weekend Holiday Rule + Yes, !- Use Weather File Rain Indicators + Yes; !- Use Weather File Snow Indicators + +ShadowCalculation, + PolygonClipping, !- Shading Calculation Method + Periodic, !- Shading Calculation Update Frequency Method + 20, !- Shading Calculation Update Frequency + 15000, !- Maximum Figures in Shadow Overlap Calculations + SutherlandHodgman, !- Polygon Clipping Algorithm + 512, !- Pixel Counting Resolution + SimpleSkyDiffuseModeling, !- Sky Diffuse Modeling Algorithm + No, !- Output External Shading Calculation Results + No, !- Disable Self-Shading Within Shading Zone Groups + No; !- Disable Self-Shading From Shading Zone Groups to Other Zones + +SurfaceConvectionAlgorithm:Inside, + TARP; !- Algorithm + +SurfaceConvectionAlgorithm:Outside, + DOE-2; !- Algorithm + +Sizing:Parameters, + 1.25, !- Heating Sizing Factor + 1.15; !- Cooling Sizing Factor + +ZoneAirContaminantBalance, + No; !- Carbon Dioxide Concentration + +ZoneAirHeatBalanceAlgorithm, + ThirdOrderBackwardDifference; !- Algorithm + +ZoneCapacitanceMultiplier:ResearchSpecial, + Zone Capacitance Multiplier Research Special, !- Name + , !- Zone or ZoneList Name + , !- Temperature Capacity Multiplier + , !- Humidity Capacity Multiplier + , !- Carbon Dioxide Capacity Multiplier + ; !- Generic Contaminant Capacity Multiplier + +GlobalGeometryRules, + UpperLeftCorner, !- Starting Vertex Position + Counterclockwise, !- Vertex Entry Direction + Relative, !- Coordinate System + Relative, !- Daylighting Reference Point Coordinate System + Relative; !- Rectangular Surface Coordinate System + +! ################################################################################# +! schedule type setting +ScheduleTypeLimits, + ActivityLevel, !- Name + 0, !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + activitylevel; !- Unit Type + +ScheduleTypeLimits, + ActivityLevel 13, !- Name + 0, !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + activitylevel; !- Unit Type + +ScheduleTypeLimits, + Fraction, !- Name + 0, !- Lower Limit Value + 1, !- Upper Limit Value + CONTINUOUS; !- Numeric Type + +ScheduleTypeLimits, + OnOff, !- Name + 0, !- Lower Limit Value + 1, !- Upper Limit Value + Discrete, !- Numeric Type + availability; !- Unit Type + +Schedule:Constant, + Always On Discrete, !- Name + OnOff, !- Schedule Type Limits Name + 1; !- Hourly Value + +Schedule:Constant, + Always On Discrete 1, !- Name + OnOff, !- Schedule Type Limits Name + 1; !- Hourly Value + +Schedule:Constant, + Always Off Discrete, !- Name + , !- Schedule Type Limits Name + 0; !- Hourly Value + +Schedule:Constant, + Always On Discrete hvac_library, !- Name + OnOff hvac_library, !- Schedule Type Limits Name + 1; + +Schedule:Constant, + Always On Continuous, !- Name + , !- Schedule Type Limits Name + 1; !- Hourly Value + +ScheduleTypeLimits, + Temperature 36, !- Name + , !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + temperature; !- Unit Type + +ScheduleTypeLimits, + Temperature 37, !- Name + , !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + temperature; !- Unit Type + +OutdoorAir:Node, + Model Outdoor Air Node; !- Name + +! ==================================== Execution 3 Successful ==================================== +! ==================================== Execution 4 Started ==================================== +! ========== Error during execution: name 'chilled_system' is not defined ========== + +ScheduleTypeLimits, + OnOff hvac_library, !- Name + 0, !- Lower Limit Value {BasedOnField A3} + 1, !- Upper Limit Value {BasedOnField A3} + Discrete, !- Numeric Type + availability; !- Unit Type + +Curve:Exponent, + Fan On Off Power Curve 12, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 Constant + 0, !- Coefficient3 Constant + 0, !- Minimum Value of x {BasedOnField A2} + 1; !- Maximum Value of x {BasedOnField A2} + +Curve:Cubic, + Fan On Off Efficiency Curve 12, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 0, !- Minimum Value of x {BasedOnField A2} + 1; !- Maximum Value of x {BasedOnField A2} + +Building, + Building 1, !- Name + -0, !- North Axis {deg} + , !- Terrain + , !- Loads Convergence Tolerance Value {W} + , !- Temperature Convergence Tolerance Value {deltaC} + , !- Solar Distribution + , !- Maximum Number of Warmup Days + ; !- Minimum Number of Warmup Days + +Version, + 9.6; !- Version Identifier + +Timestep, + 1; !- Number of Timesteps per Hour + +LifeCycleCost:Parameters, + Life Cycle Cost Parameters, !- Name + EndOfYear, !- Discounting Convention + ConstantDollar, !- Inflation Approach + 0.03, !- Real Discount Rate + , !- Nominal Discount Rate + , !- Inflation + , !- Base Date Month + 2011, !- Base Date Year + , !- Service Date Month + 2011, !- Service Date Year + 25, !- Length of Study Period in Years + , !- Tax rate + None; !- Depreciation Method + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Electricity, !- Name + Electricity, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9838, !- Year Escalation 1 + 0.9730, !- Year Escalation 2 + 0.9632, !- Year Escalation 3 + 0.9611, !- Year Escalation 4 + 0.9571, !- Year Escalation 5 + 0.9553, !- Year Escalation 6 + 0.9539, !- Year Escalation 7 + 0.9521, !- Year Escalation 8 + 0.9546, !- Year Escalation 9 + 0.9550, !- Year Escalation 10 + 0.9553, !- Year Escalation 11 + 0.9564, !- Year Escalation 12 + 0.9575, !- Year Escalation 13 + 0.9596, !- Year Escalation 14 + 0.9618, !- Year Escalation 15 + 0.9614, !- Year Escalation 16 + 0.9618, !- Year Escalation 17 + 0.9618, !- Year Escalation 18 + 0.9593, !- Year Escalation 19 + 0.9589, !- Year Escalation 20 + 0.9607, !- Year Escalation 21 + 0.9625, !- Year Escalation 22 + 0.9650, !- Year Escalation 23 + 0.9708, !- Year Escalation 24 + 0.9751, !- Year Escalation 25 + 0.9762, !- Year Escalation 26 + 0.9766, !- Year Escalation 27 + 0.9766, !- Year Escalation 28 + 0.9769, !- Year Escalation 29 + 0.9773; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Distillate Oil, !- Name + FuelOilNo1, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9714, !- Year Escalation 1 + 0.9730, !- Year Escalation 2 + 0.9942, !- Year Escalation 3 + 1.0164, !- Year Escalation 4 + 1.0541, !- Year Escalation 5 + 1.0928, !- Year Escalation 6 + 1.1267, !- Year Escalation 7 + 1.1580, !- Year Escalation 8 + 1.1792, !- Year Escalation 9 + 1.1967, !- Year Escalation 10 + 1.2200, !- Year Escalation 11 + 1.2333, !- Year Escalation 12 + 1.2566, !- Year Escalation 13 + 1.2709, !- Year Escalation 14 + 1.2826, !- Year Escalation 15 + 1.2985, !- Year Escalation 16 + 1.3102, !- Year Escalation 17 + 1.3250, !- Year Escalation 18 + 1.3261, !- Year Escalation 19 + 1.3282, !- Year Escalation 20 + 1.3324, !- Year Escalation 21 + 1.3356, !- Year Escalation 22 + 1.3431, !- Year Escalation 23 + 1.3510, !- Year Escalation 24 + 1.3568, !- Year Escalation 25 + 1.3606, !- Year Escalation 26 + 1.3637, !- Year Escalation 27 + 1.3674, !- Year Escalation 28 + 1.3706, !- Year Escalation 29 + 1.3743; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Residual Oil, !- Name + FuelOilNo2, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.8469, !- Year Escalation 1 + 0.8257, !- Year Escalation 2 + 0.8681, !- Year Escalation 3 + 0.8988, !- Year Escalation 4 + 0.9289, !- Year Escalation 5 + 0.9604, !- Year Escalation 6 + 0.9897, !- Year Escalation 7 + 1.0075, !- Year Escalation 8 + 1.0314, !- Year Escalation 9 + 1.0554, !- Year Escalation 10 + 1.0861, !- Year Escalation 11 + 1.1278, !- Year Escalation 12 + 1.1497, !- Year Escalation 13 + 1.1620, !- Year Escalation 14 + 1.1743, !- Year Escalation 15 + 1.1852, !- Year Escalation 16 + 1.1948, !- Year Escalation 17 + 1.2037, !- Year Escalation 18 + 1.2071, !- Year Escalation 19 + 1.2119, !- Year Escalation 20 + 1.2139, !- Year Escalation 21 + 1.2194, !- Year Escalation 22 + 1.2276, !- Year Escalation 23 + 1.2365, !- Year Escalation 24 + 1.2420, !- Year Escalation 25 + 1.2461, !- Year Escalation 26 + 1.2509, !- Year Escalation 27 + 1.2550, !- Year Escalation 28 + 1.2591, !- Year Escalation 29 + 1.2638; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Natural gas, !- Name + NaturalGas, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9823, !- Year Escalation 1 + 0.9557, !- Year Escalation 2 + 0.9279, !- Year Escalation 3 + 0.9257, !- Year Escalation 4 + 0.9346, !- Year Escalation 5 + 0.9412, !- Year Escalation 6 + 0.9512, !- Year Escalation 7 + 0.9645, !- Year Escalation 8 + 0.9856, !- Year Escalation 9 + 1.0067, !- Year Escalation 10 + 1.0222, !- Year Escalation 11 + 1.0410, !- Year Escalation 12 + 1.0610, !- Year Escalation 13 + 1.0787, !- Year Escalation 14 + 1.0942, !- Year Escalation 15 + 1.1098, !- Year Escalation 16 + 1.1220, !- Year Escalation 17 + 1.1308, !- Year Escalation 18 + 1.1386, !- Year Escalation 19 + 1.1486, !- Year Escalation 20 + 1.1619, !- Year Escalation 21 + 1.1763, !- Year Escalation 22 + 1.1918, !- Year Escalation 23 + 1.2118, !- Year Escalation 24 + 1.2284, !- Year Escalation 25 + 1.2439, !- Year Escalation 26 + 1.2605, !- Year Escalation 27 + 1.2772, !- Year Escalation 28 + 1.2938, !- Year Escalation 29 + 1.3115; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Coal, !- Name + Coal, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9970, !- Year Escalation 1 + 1.0089, !- Year Escalation 2 + 1.0089, !- Year Escalation 3 + 0.9941, !- Year Escalation 4 + 0.9941, !- Year Escalation 5 + 1.0000, !- Year Escalation 6 + 1.0030, !- Year Escalation 7 + 1.0059, !- Year Escalation 8 + 1.0089, !- Year Escalation 9 + 1.0119, !- Year Escalation 10 + 1.0148, !- Year Escalation 11 + 1.0178, !- Year Escalation 12 + 1.0208, !- Year Escalation 13 + 1.0267, !- Year Escalation 14 + 1.0297, !- Year Escalation 15 + 1.0356, !- Year Escalation 16 + 1.0415, !- Year Escalation 17 + 1.0534, !- Year Escalation 18 + 1.0564, !- Year Escalation 19 + 1.0593, !- Year Escalation 20 + 1.0653, !- Year Escalation 21 + 1.0712, !- Year Escalation 22 + 1.0742, !- Year Escalation 23 + 1.0801, !- Year Escalation 24 + 1.0831, !- Year Escalation 25 + 1.0831, !- Year Escalation 26 + 1.0861, !- Year Escalation 27 + 1.0890, !- Year Escalation 28 + 1.0920, !- Year Escalation 29 + 1.0950; !- Year Escalation 30 + +OutputControl:ReportingTolerances, + 0.2, !- Tolerance for Time Heating Setpoint Not Met {deltaC} + 0.2; !- Tolerance for Time Cooling Setpoint Not Met {deltaC} + +Output:JSON, + TimeSeriesAndTabular, !- Option Type + No, !- Output JSON + No, !- Output CBOR + No; !- Output MessagePack + +Output:Table:SummaryReports, + AllSummary; !- Report Name 1 + +Site:Location, + Washington Dc Dulles IntL Ar, !- Name + 38.98, !- Latitude {deg} + -77.47, !- Longitude {deg} + -5, !- Time Zone {hr} + 82; !- Elevation {m} + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns DB=>MWB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 36.5, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 17.1, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns DP=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 22.5, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Dewpoint, !- Humidity Condition Type + 15.6, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns Enth=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 30.8, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Enthalpy, !- Humidity Condition Type + , !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + 59300, !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns WB=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 31.2, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 19, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Htg 99.6% Condns DB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + -12.4, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + -12.4, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 2.6, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Htg Wind 99.6% Condns WS=>MCDB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + 6.8, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 6.8, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 12.4, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Hum_n 99.6% Condns DP=>MCDB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + -10.7, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Dewpoint, !- Humidity Condition Type + -16.2, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 2.6, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + + + +OutputControl:Table:Style, + HTML; !- Column Separator + +Output:VariableDictionary, + IDF, !- Key Field + Unsorted; !- Sort Option + +Output:SQLite, + SimpleAndTabular; !- Option Type + +LifeCycleCost:NonrecurringCost, + Default Cost, !- Name + Construction, !- Category + 0, !- Cost + ServicePeriod; !- Start of Costs + +Output:Table:Monthly, + Building Energy Performance - Electricity, !- Name + 2, !- Digits After Decimal + InteriorLights:Electricity, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:Electricity, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:Electricity, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:Electricity, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:Electricity, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:Electricity, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:Electricity, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:Electricity, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:Electricity, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:Electricity, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:Electricity, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:Electricity, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:Electricity, !- Variable or Meter Name 13 + SumOrAverage, !- Aggregation Type for Variable or Meter 13 + Refrigeration:Electricity, !- Variable or Meter Name 14 + SumOrAverage; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - Natural Gas, !- Name + 2, !- Digits After Decimal + InteriorEquipment:NaturalGas, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorEquipment:NaturalGas, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + Heating:NaturalGas, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + Cooling:NaturalGas, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + WaterSystems:NaturalGas, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Cogeneration:NaturalGas, !- Variable or Meter Name 6 + SumOrAverage; !- Aggregation Type for Variable or Meter 6 + +Output:Table:Monthly, + Building Energy Performance - District Heating, !- Name + 2, !- Digits After Decimal + InteriorLights:DistrictHeating, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:DistrictHeating, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:DistrictHeating, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:DistrictHeating, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:DistrictHeating, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:DistrictHeating, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:DistrictHeating, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:DistrictHeating, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:DistrictHeating, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:DistrictHeating, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:DistrictHeating, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:DistrictHeating, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:DistrictHeating, !- Variable or Meter Name 13 + SumOrAverage; !- Aggregation Type for Variable or Meter 13 + +Output:Table:Monthly, + Building Energy Performance - District Cooling, !- Name + 2, !- Digits After Decimal + InteriorLights:DistrictCooling, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:DistrictCooling, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:DistrictCooling, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:DistrictCooling, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:DistrictCooling, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:DistrictCooling, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:DistrictCooling, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:DistrictCooling, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:DistrictCooling, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:DistrictCooling, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:DistrictCooling, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:DistrictCooling, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:DistrictCooling, !- Variable or Meter Name 13 + SumOrAverage; !- Aggregation Type for Variable or Meter 13 + +Output:Table:Monthly, + Building Energy Performance - Electricity Peak Demand, !- Name + 2, !- Digits After Decimal + Electricity:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:Electricity, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:Electricity, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:Electricity, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:Electricity, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:Electricity, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:Electricity, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:Electricity, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:Electricity, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:Electricity, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:Electricity, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:Electricity, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:Electricity, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:Electricity, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - Natural Gas Peak Demand, !- Name + 2, !- Digits After Decimal + NaturalGas:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorEquipment:NaturalGas, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorEquipment:NaturalGas, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + Heating:NaturalGas, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + Cooling:NaturalGas, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + WaterSystems:NaturalGas, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Cogeneration:NaturalGas, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 7 + +Output:Table:Monthly, + Building Energy Performance - District Heating Peak Demand, !- Name + 2, !- Digits After Decimal + DistrictHeating:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:DistrictHeating, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:DistrictHeating, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:DistrictHeating, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:DistrictHeating, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:DistrictHeating, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:DistrictHeating, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:DistrictHeating, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:DistrictHeating, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:DistrictHeating, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:DistrictHeating, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:DistrictHeating, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:DistrictHeating, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:DistrictHeating, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - District Cooling Peak Demand, !- Name + 2, !- Digits After Decimal + DistrictCooling:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:DistrictCooling, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:DistrictCooling, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:DistrictCooling, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:DistrictCooling, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:DistrictCooling, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:DistrictCooling, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:DistrictCooling, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:DistrictCooling, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:DistrictCooling, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:DistrictCooling, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:DistrictCooling, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:DistrictCooling, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:DistrictCooling, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +!- =========== ALL OBJECTS IN CLASS: OUTPUT:METER =========== + +Output:Meter, + Electricity:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + NaturalGas:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + DistrictCooling:Facility,!- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + DistrictHeating:Facility,!- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + NaturalGas:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + Electricity:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + DistrictCooling:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + DistrictHeating:Facility, !- Key Name + Timestep; !- Reporting Frequency +