diff --git "a/validated building models/LLM-BEM-Engineer_Generated_Building_Model_4_2.idf" "b/validated building models/LLM-BEM-Engineer_Generated_Building_Model_4_2.idf" new file mode 100644--- /dev/null +++ "b/validated building models/LLM-BEM-Engineer_Generated_Building_Model_4_2.idf" @@ -0,0 +1,5058 @@ +! ==================================== Execution 1 Started ==================================== + + +BuildingSurface:Detailed,Floor 1 0,Floor,ExtSlabCarpet,Thermal Zone 1,,Ground,,NoSun,NoWind,,,0,0,0,213.83,0,0,213.83,33.08,0,0,33.08,0; +BuildingSurface:Detailed,Floor 2 0,Floor,ExtSlabCarpet,Thermal Zone 2,,Ground,,NoSun,NoWind,,,0,33.08,0,190.57,33.08,0,190.57,96.69,0,0,96.69,0; +BuildingSurface:Detailed,Floor 3 0,Floor,ExtSlabCarpet,Thermal Zone 3,,Ground,,NoSun,NoWind,,,167.40,33.08,0,213.83,33.08,0,213.83,250.00,0,167.40,250.00,0; + + +BuildingSurface:Detailed,Ceiling 1 0,Ceiling,Interior Ceiling,Thermal Zone 1,,Surface,Floor 1 1,NoSun,NoWind,,,0,0,12.82,213.83,0,12.82,213.83,33.08,12.82,0,33.08,12.82; +BuildingSurface:Detailed,Ceiling 2 0,Ceiling,Interior Ceiling,Thermal Zone 2,,Surface,Floor 2 1,NoSun,NoWind,,,0,33.08,12.82,190.57,33.08,12.82,190.57,96.69,12.82,0,96.69,12.82; +BuildingSurface:Detailed,Ceiling 3 0,Ceiling,Interior Ceiling,Thermal Zone 3,,Surface,Floor 3 1,NoSun,NoWind,,,167.40,33.08,12.82,213.83,33.08,12.82,213.83,250.00,12.82,167.40,250.00,12.82; + +BuildingSurface:Detailed,Face 10 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,213.83,0,12.82,0,0,12.82,0,0,0,213.83,0,0; +BuildingSurface:Detailed,Face 2 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,0,0,12.82,0,33.08,12.82,0,33.08,0,0,0,0; +BuildingSurface:Detailed,Face 5 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,190.57,33.08,12.82,167.40,33.08,12.82,167.40,33.08,0,190.57,33.08,0; +BuildingSurface:Detailed,Face 8 0,Wall,Ext Wall,Thermal Zone 1,,Outdoors,,SunExposed,WindExposed,,,213.83,33.08,12.82,213.83,0,12.82,213.83,0,0,213.83,33.08,0; +BuildingSurface:Detailed,Face 14 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,0,33.08,12.82,0,96.69,12.82,0,96.69,0,0,33.08,0; +BuildingSurface:Detailed,Face 16 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,0,96.69,12.82,190.57,96.69,12.82,190.57,96.69,0,0,96.69,0; +BuildingSurface:Detailed,Face 18 0,Wall,Ext Wall,Thermal Zone 2,,Outdoors,,SunExposed,WindExposed,,,190.57,96.69,12.82,190.57,33.08,12.82,190.57,33.08,0,190.57,96.69,0; +BuildingSurface:Detailed,Face 23 0,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,213.83,250.00,12.82,213.83,33.08,12.82,213.83,33.08,0,213.83,250.00,0; +BuildingSurface:Detailed,Face 26 0,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,167.40,33.08,12.82,167.40,250.00,12.82,167.40,250.00,0,167.40,33.08,0; +BuildingSurface:Detailed,Face 28 0,Wall,Ext Wall,Thermal Zone 3,,Outdoors,,SunExposed,WindExposed,,,167.40,250.00,12.82,213.83,250.00,12.82,213.83,250.00,0,167.40,250.00,0; + +BuildingSurface:Detailed,Face 4 0,Wall,Interior Wall,Thermal Zone 1,,Surface,Face 20 0,NoSun,NoWind,,,0,33.08,12.82,190.57,33.08,12.82,190.57,33.08,0,0,33.08,0; +BuildingSurface:Detailed,Face 7 0,Wall,Interior Wall,Thermal Zone 1,,Surface,Face 25 0,NoSun,NoWind,,,167.40,33.08,12.82,213.83,33.08,12.82,213.83,33.08,0,167.40,33.08,0; +BuildingSurface:Detailed,Face 20 0,Wall,Interior Wall,Thermal Zone 2,,Surface,Face 4 0,NoSun,NoWind,,,190.57,33.08,12.82,190.57,33.08,0,0,33.08,0,0,33.08,12.82; +BuildingSurface:Detailed,Face 25 0,Wall,Interior Wall,Thermal Zone 3,,Surface,Face 7 0,NoSun,NoWind,,,213.83,33.08,12.82,213.83,33.08,0,167.40,33.08,0,167.40,33.08,12.82; + +! ewin +FenestrationSurface:Detailed,Face 9 0,Window,Ext Window,Face 8 0,,,,,,213.83,0.01,11.67,213.83,0.01,1.15,213.83,33.07,1.15,213.83,33.07,11.67; +FenestrationSurface:Detailed,Face 19 0,Window,Ext Window,Face 18 0,,,,,,190.57,33.09,11.67,190.57,33.09,1.15,190.57,96.68,1.15,190.57,96.68,11.67; +FenestrationSurface:Detailed,Face 24 0,Window,Ext Window,Face 23 0,,,,,,213.83,33.09,11.67,213.83,33.09,1.15,213.83,249.99,1.15,213.83,249.99,11.67; + +! nwin +FenestrationSurface:Detailed,Face 6 0,Window,Ext Window,Face 5 0,,,,,,167.39,33.08,8.78,167.39,33.08,4.04,190.58,33.08,4.04,190.58,33.08,8.78; +FenestrationSurface:Detailed,Face 17 0,Window,Ext Window,Face 16 0,,,,,,190.56,96.69,8.78,190.56,96.69,4.04,0.01,96.69,4.04,0.01,96.69,8.78; +FenestrationSurface:Detailed,Face 29 0,Window,Ext Window,Face 28 0,,,,,,213.82,250.00,8.78,213.82,250.00,4.04,167.41,250.00,4.04,167.41,250.00,8.78; + +! swin +FenestrationSurface:Detailed,Face 11 0,Window,Ext Window,Face 10 0,,,,,,0.01,0,9.04,0.01,0,3.78,213.82,0,3.78,213.82,0,9.04; + +! wwin +FenestrationSurface:Detailed,Face 3 0,Window,Ext Window,Face 2 0,,,,,,0,33.07,10.19,0,33.07,2.63,0,0.01,2.63,0,0.01,10.19; +FenestrationSurface:Detailed,Face 15 0,Window,Ext Window,Face 14 0,,,,,,0,96.68,10.19,0,96.68,2.63,0,33.09,2.63,0,33.09,10.19; +FenestrationSurface:Detailed,Face 27 0,Window,Ext Window,Face 26 0,,,,,,167.40,249.99,10.19,167.40,249.99,2.63,167.40,33.09,2.63,167.40,33.09,10.19; + +Zone,Thermal Zone 1,198.00,0,0,0.00,,1,,,,,,Yes; +Zone,Thermal Zone 2,198.00,0,0,0.00,,1,,,,,,Yes; +Zone,Thermal Zone 3,198.00,0,0,0.00,,1,,,,,,Yes; + + +BuildingSurface:Detailed,Floor 1 1,Floor,Interior Floor,Thermal Zone 4,,Surface,Ceiling 1 0,NoSun,NoWind,,,0,0,0,213.83,0,0,213.83,33.08,0,0,33.08,0; +BuildingSurface:Detailed,Floor 2 1,Floor,Interior Floor,Thermal Zone 5,,Surface,Ceiling 2 0,NoSun,NoWind,,,0,33.08,0,190.57,33.08,0,190.57,96.69,0,0,96.69,0; +BuildingSurface:Detailed,Floor 3 1,Floor,Interior Floor,Thermal Zone 6,,Surface,Ceiling 3 0,NoSun,NoWind,,,167.40,33.08,0,213.83,33.08,0,213.83,250.00,0,167.40,250.00,0; + + +BuildingSurface:Detailed,Roof 1 1,Roof,Ext Roof,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,0,0,5.47,213.83,0,5.47,213.83,33.08,5.47,0,33.08,5.47; +BuildingSurface:Detailed,Roof 2 1,Roof,Ext Roof,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,0,33.08,5.47,190.57,33.08,5.47,190.57,96.69,5.47,0,96.69,5.47; +BuildingSurface:Detailed,Roof 3 1,Roof,Ext Roof,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,167.40,33.08,5.47,213.83,33.08,5.47,213.83,250.00,5.47,167.40,250.00,5.47; + +BuildingSurface:Detailed,Face 10 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,213.83,0,5.47,0,0,5.47,0,0,0,213.83,0,0; +BuildingSurface:Detailed,Face 2 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,0,0,5.47,0,33.08,5.47,0,33.08,0,0,0,0; +BuildingSurface:Detailed,Face 5 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,190.57,33.08,5.47,167.40,33.08,5.47,167.40,33.08,0,190.57,33.08,0; +BuildingSurface:Detailed,Face 8 1,Wall,Ext Wall,Thermal Zone 4,,Outdoors,,SunExposed,WindExposed,,,213.83,33.08,5.47,213.83,0,5.47,213.83,0,0,213.83,33.08,0; +BuildingSurface:Detailed,Face 14 1,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,0,33.08,5.47,0,96.69,5.47,0,96.69,0,0,33.08,0; +BuildingSurface:Detailed,Face 16 1,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,0,96.69,5.47,190.57,96.69,5.47,190.57,96.69,0,0,96.69,0; +BuildingSurface:Detailed,Face 18 1,Wall,Ext Wall,Thermal Zone 5,,Outdoors,,SunExposed,WindExposed,,,190.57,96.69,5.47,190.57,33.08,5.47,190.57,33.08,0,190.57,96.69,0; +BuildingSurface:Detailed,Face 23 1,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,213.83,250.00,5.47,213.83,33.08,5.47,213.83,33.08,0,213.83,250.00,0; +BuildingSurface:Detailed,Face 26 1,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,167.40,33.08,5.47,167.40,250.00,5.47,167.40,250.00,0,167.40,33.08,0; +BuildingSurface:Detailed,Face 28 1,Wall,Ext Wall,Thermal Zone 6,,Outdoors,,SunExposed,WindExposed,,,167.40,250.00,5.47,213.83,250.00,5.47,213.83,250.00,0,167.40,250.00,0; + +BuildingSurface:Detailed,Face 4 1,Wall,Interior Wall,Thermal Zone 4,,Surface,Face 20 1,NoSun,NoWind,,,0,33.08,5.47,190.57,33.08,5.47,190.57,33.08,0,0,33.08,0; +BuildingSurface:Detailed,Face 7 1,Wall,Interior Wall,Thermal Zone 4,,Surface,Face 25 1,NoSun,NoWind,,,167.40,33.08,5.47,213.83,33.08,5.47,213.83,33.08,0,167.40,33.08,0; +BuildingSurface:Detailed,Face 20 1,Wall,Interior Wall,Thermal Zone 5,,Surface,Face 4 1,NoSun,NoWind,,,190.57,33.08,5.47,190.57,33.08,0,0,33.08,0,0,33.08,5.47; +BuildingSurface:Detailed,Face 25 1,Wall,Interior Wall,Thermal Zone 6,,Surface,Face 7 1,NoSun,NoWind,,,213.83,33.08,5.47,213.83,33.08,0,167.40,33.08,0,167.40,33.08,5.47; + +! ewin +FenestrationSurface:Detailed,Face 9 1,Window,Ext Window,Face 8 1,,,,,,213.83,0.01,4.98,213.83,0.01,0.49,213.83,33.07,0.49,213.83,33.07,4.98; +FenestrationSurface:Detailed,Face 19 1,Window,Ext Window,Face 18 1,,,,,,190.57,33.09,4.98,190.57,33.09,0.49,190.57,96.68,0.49,190.57,96.68,4.98; +FenestrationSurface:Detailed,Face 24 1,Window,Ext Window,Face 23 1,,,,,,213.83,33.09,4.98,213.83,33.09,0.49,213.83,249.99,0.49,213.83,249.99,4.98; + +! nwin +FenestrationSurface:Detailed,Face 6 1,Window,Ext Window,Face 5 1,,,,,,167.39,33.08,3.75,167.39,33.08,1.72,190.58,33.08,1.72,190.58,33.08,3.75; +FenestrationSurface:Detailed,Face 17 1,Window,Ext Window,Face 16 1,,,,,,190.56,96.69,3.75,190.56,96.69,1.72,0.01,96.69,1.72,0.01,96.69,3.75; +FenestrationSurface:Detailed,Face 29 1,Window,Ext Window,Face 28 1,,,,,,213.82,250.00,3.75,213.82,250.00,1.72,167.41,250.00,1.72,167.41,250.00,3.75; + +! swin +FenestrationSurface:Detailed,Face 11 1,Window,Ext Window,Face 10 1,,,,,,0.01,0,3.86,0.01,0,1.61,213.82,0,1.61,213.82,0,3.86; + +! wwin +FenestrationSurface:Detailed,Face 3 1,Window,Ext Window,Face 2 1,,,,,,0,33.07,4.35,0,33.07,1.12,0,0.01,1.12,0,0.01,4.35; +FenestrationSurface:Detailed,Face 15 1,Window,Ext Window,Face 14 1,,,,,,0,96.68,4.35,0,96.68,1.12,0,33.09,1.12,0,33.09,4.35; +FenestrationSurface:Detailed,Face 27 1,Window,Ext Window,Face 26 1,,,,,,167.40,249.99,4.35,167.40,249.99,1.12,167.40,33.09,1.12,167.40,33.09,4.35; + +Zone,Thermal Zone 4,198.00,0,0,12.82,,1,,,,,,Yes; +Zone,Thermal Zone 5,198.00,0,0,12.82,,1,,,,,,Yes; +Zone,Thermal Zone 6,198.00,0,0,12.82,,1,,,,,,Yes; + +! ==================================== Execution 1 Successful ==================================== +! ==================================== Execution 2 Started ==================================== + +! wall material +Material, + wall concrete, !- Name + MediumRough, !- Roughness + 0.398, !- Thickness m + 0.5, !- Conductivity W/m-K + 2242.99999999999, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +Material, + wall gypsum, !- Name + MediumSmooth, !- Roughness + 0.398, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +Material, + wall wood, !- Name + MediumSmooth, !- Roughness + 0.398, !- Thickness m + 0.15, !- Conductivity W/m-K + 608, !- Density kg/m3 + 1630, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + wall metal, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 45.2800000000001, !- Conductivity W/m-K + 7823.99999999999, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + wall rammed earth, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 1.5, !- Conductivity W/m-K + 1540.0, !- Density kg/m3 + 1260, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + wall brick, !- Name + Smooth, !- Roughness + 0.398, !- Thickness m + 0.7, !- Conductivity W/m-K + 1800.0, !- Density kg/m3 + 829, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +! roof material +Material, + roof concrete, !- Name + MediumRough, !- Roughness + 0.401, !- Thickness m + 0.5, !- Conductivity W/m-K + 2242.99999999999, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + +Material, + roof gypsum, !- Name + MediumSmooth, !- Roughness + 0.401, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +Material, + roof wood, !- Name + MediumSmooth, !- Roughness + 0.401, !- Thickness m + 0.15, !- Conductivity W/m-K + 608, !- Density kg/m3 + 1630, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + roof metal, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 45.2800000000001, !- Conductivity W/m-K + 7823.99999999999, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + roof rammed earth, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 1.5, !- Conductivity W/m-K + 1540.0, !- Density kg/m3 + 1260, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + roof brick, !- Name + Smooth, !- Roughness + 0.401, !- Thickness m + 0.7, !- Conductivity W/m-K + 1800.0, !- Density kg/m3 + 829, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.65, !- Solar Absorptance + 0.65; !- Visible Absorptance + + + +! wall insu + + + + + + + +! extro wall materials +Material, + Wall Insulation [19], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [20], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [22], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [23], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [24], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [27], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [28], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [29], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [30], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [32], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [33], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [34], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [38], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [39], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [41], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +! [43]=[44] +Material, + Wall Insulation [43], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + + +! extro roof materials +Material, + Roof Insulation [19], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [20], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [22], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [23], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [24], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [27], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [28], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [29], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [30], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [32], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [33], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [34], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [38], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [39], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [41], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +! [43]=[44] +Material, + Roof Insulation [43], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + + + + + +! real materials +Material, + Wall Insulation [18], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [21], !- Name + MediumRough, !- Roughness + 0.2105, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [25], !- Name + MediumRough, !- Roughness + 0.263, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [26], !- Name + MediumRough, !- Roughness + 0.2941, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Wall Insulation [31], !- Name + MediumRough, !- Roughness + 0.0337000000000001, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [35], !- Name + MediumRough, !- Roughness + 0.0452, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [36], !- Name + MediumRough, !- Roughness + 0.0565999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [37], !- Name + MediumRough, !- Roughness + 0.0680999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [40], !- Name + MediumRough, !- Roughness + 0.0793999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [42], !- Name + MediumRough, !- Roughness + 0.0913999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Wall Insulation [44], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +! roof insu +Material, + Roof Insulation [18], !- Name + MediumRough, !- Roughness + 0.1693, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [21], !- Name + MediumRough, !- Roughness + 0.2105, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [25], !- Name + MediumRough, !- Roughness + 0.263, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [26], !- Name + MediumRough, !- Roughness + 0.2941, !- Thickness m + 0.049, !- Conductivity W/m-K + 265, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.7, !- Solar Absorptance + 0.7; !- Visible Absorptance + +Material, + Roof Insulation [31], !- Name + MediumRough, !- Roughness + 0.0337000000000001, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [35], !- Name + MediumRough, !- Roughness + 0.0452, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [36], !- Name + MediumRough, !- Roughness + 0.0565999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [37], !- Name + MediumRough, !- Roughness + 0.0680999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [40], !- Name + MediumRough, !- Roughness + 0.0793999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [42], !- Name + MediumRough, !- Roughness + 0.0913999999999999, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + Roof Insulation [44], !- Name + MediumRough, !- Roughness + 0.1104, !- Thickness m + 0.0432, !- Conductivity W/m-K + 91, !- Density kg/m3 + 836.999999999999, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + + + +Material, + F16 Acoustic tile, !- Name + MediumSmooth, !- Roughness + 0.0191, !- Thickness m + 0.06, !- Conductivity W/m-K + 368, !- Density kg/m3 + 590.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.3, !- Solar Absorptance + 0.3; !- Visible Absorptance + + +Material, + I01 25mm insulation board, !- Name + MediumRough, !- Roughness + 0.0254, !- Thickness m + 0.03, !- Conductivity W/m-K + 43, !- Density kg/m3 + 1210, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.6, !- Solar Absorptance + 0.6; !- Visible Absorptance + +Material, + M11 100mm lightweight concrete, !- Name + MediumRough, !- Roughness + 0.1016, !- Thickness m + 0.53, !- Conductivity W/m-K + 1280, !- Density kg/m3 + 840.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + M11 100mm lightweight concrete 1, !- Name + MediumRough, !- Roughness + 0.1016, !- Thickness m + 0.53, !- Conductivity W/m-K + 1280, !- Density kg/m3 + 840.000000000002, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material, + MAT-CC05 4 HW CONCRETE, !- Name + Rough, !- Roughness + 0.1016, !- Thickness m + 1.311, !- Conductivity W/m-K + 2240, !- Density kg/m3 + 836.800000000001, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.85, !- Solar Absorptance + 0.85; !- Visible Absorptance + +Material, + Metal Roofing, !- Name + MediumSmooth, !- Roughness + 0.0015, !- Thickness m + 45.006, !- Conductivity W/m-K + 7680, !- Density kg/m3 + 418.4, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.6, !- Solar Absorptance + 0.6; !- Visible Absorptance + +Material, + Pipe Steel, !- Name + Smooth, !- Roughness + 0.003, !- Thickness m + 45.31, !- Conductivity W/m-K + 7833, !- Density kg/m3 + 500, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.5, !- Solar Absorptance + 0.5; !- Visible Absorptance + +Material:AirGap, + F04 Wall air space resistance, !- Name + 0.15; !- Thermal Resistance m2-K/W + +Material:AirGap, + F05 Ceiling air space resistance, !- Name + 0.18; !- Thermal Resistance m2-K/W + +Material:NoMass, + CP02 CARPET PAD, !- Name + Smooth, !- Roughness + 0.1, !- Thermal Resistance m2-K/W + 0.9, !- Thermal Absorptance + 0.8, !- Solar Absorptance + 0.8; !- Visible Absorptance + +Material, + G01a 19mm gypsum board, !- Name + MediumSmooth, !- Roughness + 0.019, !- Thickness m + 0.16, !- Conductivity W/m-K + 800, !- Density kg/m3 + 1090, !- Specific Heat J/kg-K + 0.9, !- Thermal Absorptance + 0.4, !- Solar Absorptance + 0.4; !- Visible Absorptance + +WindowMaterial:SimpleGlazingSystem, + Window Material Simple Glazing System, !- Name + 1.51, !- U-Factor W/m2-K + 0.25; !- Solar Heat Gain Coefficient + +Construction, + Ext Roof, !- Name + roof concrete, !- Layer 1 + Roof Insulation [25]; !- Layer 2 + +Construction, + Ext Wall, !- Name + wall concrete, !- Layer 1 + Wall Insulation [37]; !- Layer 2 + +Construction, + Ext Window, !- Name + Window Material Simple Glazing System; !- Layer 1 + +Construction, + ExtSlabCarpet, !- Name + MAT-CC05 4 HW CONCRETE, !- Layer 1 + CP02 CARPET PAD; !- Layer 2 + +Construction, + Interior Ceiling, !- Name + M11 100mm lightweight concrete, !- Layer 1 + F05 Ceiling air space resistance, !- Layer 2 + F16 Acoustic tile; !- Layer 3 + +Construction, + Interior Floor, !- Name + F16 Acoustic tile, !- Layer 1 + F05 Ceiling air space resistance, !- Layer 2 + M11 100mm lightweight concrete; !- Layer 3 + +Construction, + Interior Wall, !- Name + G01a 19mm gypsum board, !- Layer 1 + F04 Wall air space resistance, !- Layer 2 + G01a 19mm gypsum board; !- Layer 3 +ZoneList, + Space Type 1, !- Name + Thermal Zone 1, !- Zone Name 1 + Thermal Zone 2; !- Zone Name 2 + +Lights, + Lights 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 8.87, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 5.53, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 1; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 1, !- Name + Space Type 1, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 1, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 7.14, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 132; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 1 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 1, !- Sunday Schedule:Day Name + Activity Default Schedule 1, !- Monday Schedule:Day Name + Activity Default Schedule 1, !- Tuesday Schedule:Day Name + Activity Default Schedule 1, !- Wednesday Schedule:Day Name + Activity Default Schedule 1, !- Thursday Schedule:Day Name + Activity Default Schedule 1, !- Friday Schedule:Day Name + Activity Default Schedule 1, !- Saturday Schedule:Day Name + Activity Default Schedule 1, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 1, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 1; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 1, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 1, + Fraction, + No, + 01:00, 0.27, !- Value Until Time + 02:00, 0.27, !- Value Until Time + 03:00, 0.27, !- Value Until Time + 04:00, 0.27, !- Value Until Time + 05:00, 0.27, !- Value Until Time + 06:00, 0.27, !- Value Until Time + 07:00, 0.75, !- Value Until Time + 08:00, 0.75, !- Value Until Time + 09:00, 0.75, !- Value Until Time + 10:00, 0.75, !- Value Until Time + 11:00, 0.75, !- Value Until Time + 12:00, 0.75, !- Value Until Time + 13:00, 0.75, !- Value Until Time + 14:00, 0.75, !- Value Until Time + 15:00, 0.27, !- Value Until Time + 16:00, 0.27, !- Value Until Time + 17:00, 0.27, !- Value Until Time + 18:00, 0.27, !- Value Until Time + 19:00, 0.27, !- Value Until Time + 20:00, 0.27, !- Value Until Time + 21:00, 0.27, !- Value Until Time + 22:00, 0.27, !- Value Until Time + 23:00, 0.27, !- Value Until Time + 24:00, 0.27; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 1, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 1, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 1 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 1, !- Sunday Schedule:Day Name + Occ Default Schedule 1, !- Monday Schedule:Day Name + Occ Default Schedule 1, !- Tuesday Schedule:Day Name + Occ Default Schedule 1, !- Wednesday Schedule:Day Name + Occ Default Schedule 1, !- Thursday Schedule:Day Name + Occ Default Schedule 1, !- Friday Schedule:Day Name + Occ Default Schedule 1, !- Saturday Schedule:Day Name + Occ Default Schedule 1, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 1, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 1; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 1, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + +ZoneList, + Space Type 2, !- Name + Thermal Zone 3, !- Zone Name 1 + Thermal Zone 4; !- Zone Name 2 + +Lights, + Lights 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 8.29, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 8.82, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 2; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 2, !- Name + Space Type 2, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 2, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 3.49, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 114; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 2 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 2, !- Sunday Schedule:Day Name + Activity Default Schedule 2, !- Monday Schedule:Day Name + Activity Default Schedule 2, !- Tuesday Schedule:Day Name + Activity Default Schedule 2, !- Wednesday Schedule:Day Name + Activity Default Schedule 2, !- Thursday Schedule:Day Name + Activity Default Schedule 2, !- Friday Schedule:Day Name + Activity Default Schedule 2, !- Saturday Schedule:Day Name + Activity Default Schedule 2, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 2, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 2; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 2, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 2, + Fraction, + No, + 01:00, 0.19, !- Value Until Time + 02:00, 0.19, !- Value Until Time + 03:00, 0.19, !- Value Until Time + 04:00, 0.19, !- Value Until Time + 05:00, 0.19, !- Value Until Time + 06:00, 0.19, !- Value Until Time + 07:00, 0.19, !- Value Until Time + 08:00, 0.97, !- Value Until Time + 09:00, 0.97, !- Value Until Time + 10:00, 0.97, !- Value Until Time + 11:00, 0.97, !- Value Until Time + 12:00, 0.97, !- Value Until Time + 13:00, 0.97, !- Value Until Time + 14:00, 0.19, !- Value Until Time + 15:00, 0.19, !- Value Until Time + 16:00, 0.19, !- Value Until Time + 17:00, 0.19, !- Value Until Time + 18:00, 0.19, !- Value Until Time + 19:00, 0.19, !- Value Until Time + 20:00, 0.19, !- Value Until Time + 21:00, 0.19, !- Value Until Time + 22:00, 0.19, !- Value Until Time + 23:00, 0.19, !- Value Until Time + 24:00, 0.19; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 2, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 2, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 2 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 2, !- Sunday Schedule:Day Name + Occ Default Schedule 2, !- Monday Schedule:Day Name + Occ Default Schedule 2, !- Tuesday Schedule:Day Name + Occ Default Schedule 2, !- Wednesday Schedule:Day Name + Occ Default Schedule 2, !- Thursday Schedule:Day Name + Occ Default Schedule 2, !- Friday Schedule:Day Name + Occ Default Schedule 2, !- Saturday Schedule:Day Name + Occ Default Schedule 2, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 2, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 2; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 2, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + +ZoneList, + Space Type 3, !- Name + Thermal Zone 5, !- Zone Name 1 + Thermal Zone 6; !- Zone Name 2 + +Lights, + Lights 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Lighting Level {W} + 7.36, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Return Air Fraction + , !- Fraction Radiant + , !- Fraction Visible + 1, !- Fraction Replaceable + General; !- End-Use Subcategory +People, + People 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Number of People Schedule Name + Area/Person, !- Number of People Calculation Method + , !- Number of People + , !- People per Floor Area {person/m2} + 4.83, !- Floor Area per Person {m2/person} + 0.3, !- Fraction Radiant + , !- Sensible Heat Fraction + People Activity 3; !- Activity Level Schedule Name + +ElectricEquipment, + Electric Equipment 3, !- Name + Space Type 3, !- Zone or ZoneList or Space or SpaceList Name + Occpancy Schedule 3, !- Schedule Name + Watts/Area, !- Design Level Calculation Method + , !- Design Level {W} + 4.52, !- Watts per Zone Floor Area {W/m2} + , !- Watts per Person {W/person} + , !- Fraction Latent + , !- Fraction Radiant + , !- Fraction Lost + General; !- End-Use Subcategory + +! ################################################################################# +! activity +Schedule:Day:Interval, + Activity Default Schedule 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +! ################################################################################# +! activity design day +Schedule:Day:Interval, + Office Activity Summer Design Day 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +Schedule:Day:Interval, + Office Activity Winter Design Day 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 121; !- Value Until Time 1 +! ################################################################################# +! acctivity daily +Schedule:Week:Daily, + People Activity 3 Week Rule - Jan1-Dec31, !- Name + Activity Default Schedule 3, !- Sunday Schedule:Day Name + Activity Default Schedule 3, !- Monday Schedule:Day Name + Activity Default Schedule 3, !- Tuesday Schedule:Day Name + Activity Default Schedule 3, !- Wednesday Schedule:Day Name + Activity Default Schedule 3, !- Thursday Schedule:Day Name + Activity Default Schedule 3, !- Friday Schedule:Day Name + Activity Default Schedule 3, !- Saturday Schedule:Day Name + Activity Default Schedule 3, !- Holiday Schedule:Day Name + Office Activity Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Activity Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Activity Default Schedule 3, !- CustomDay1 Schedule:Day Name + Activity Default Schedule 3; !- CustomDay2 Schedule:Day Name +! acctivity year +Schedule:Year, + People Activity 3, !- Name + ActivityLevel, !- Schedule Type Limits Name + People Activity 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +Schedule:Day:Interval, + Occ Default Schedule 3, + Fraction, + No, + 01:00, 0.18, !- Value Until Time + 02:00, 0.18, !- Value Until Time + 03:00, 0.18, !- Value Until Time + 04:00, 0.18, !- Value Until Time + 05:00, 0.18, !- Value Until Time + 06:00, 0.18, !- Value Until Time + 07:00, 0.18, !- Value Until Time + 08:00, 0.18, !- Value Until Time + 09:00, 0.18, !- Value Until Time + 10:00, 0.88, !- Value Until Time + 11:00, 0.88, !- Value Until Time + 12:00, 0.88, !- Value Until Time + 13:00, 0.88, !- Value Until Time + 14:00, 0.88, !- Value Until Time + 15:00, 0.88, !- Value Until Time + 16:00, 0.88, !- Value Until Time + 17:00, 0.88, !- Value Until Time + 18:00, 0.18, !- Value Until Time + 19:00, 0.18, !- Value Until Time + 20:00, 0.18, !- Value Until Time + 21:00, 0.18, !- Value Until Time + 22:00, 0.18, !- Value Until Time + 23:00, 0.18, !- Value Until Time + 24:00, 0.18; !- Value Until Time + + +! occ design day +Schedule:Day:Interval, + Office Bldg Occ Summer Design Day 3, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 + 0, !- Value Until Time 1 + 22:00, !- Time 2 + 1, !- Value Until Time 2 + 24:00, !- Time 3 + 0.05; !- Value Until Time 3 +Schedule:Day:Interval, + Office Bldg Occ Winter Design Day 3, !- Name + Fraction, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 + 0; !- Value Until Time 1 + +! occ daily +Schedule:Week:Daily, + Occpancy Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! occ year +Schedule:Year, + Occpancy Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Occpancy Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! equip daily +Schedule:Week:Daily, + Equip Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! equip year +Schedule:Year, + Equip Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Equip Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! lighting +Schedule:Week:Daily, + Lighting Schedule 3 Week Rule - Jan1-Dec31, !- Name + Occ Default Schedule 3, !- Sunday Schedule:Day Name + Occ Default Schedule 3, !- Monday Schedule:Day Name + Occ Default Schedule 3, !- Tuesday Schedule:Day Name + Occ Default Schedule 3, !- Wednesday Schedule:Day Name + Occ Default Schedule 3, !- Thursday Schedule:Day Name + Occ Default Schedule 3, !- Friday Schedule:Day Name + Occ Default Schedule 3, !- Saturday Schedule:Day Name + Occ Default Schedule 3, !- Holiday Schedule:Day Name + Office Bldg Occ Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + Office Bldg Occ Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + Occ Default Schedule 3, !- CustomDay1 Schedule:Day Name + Occ Default Schedule 3; !- CustomDay2 Schedule:Day Name + +Schedule:Year, + Lighting Schedule 3, !- Name + Fraction, !- Schedule Type Limits Name + Lighting Schedule 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + + + + +! ##################################################################################### +! thermostat info for Thermal Zone 1 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 2 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 3 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 4 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 5 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 6 +! ##################################################################################### + + +! ##################################################################################### +! thermostat info for Thermal Zone 1 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 1 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 1, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 1, !- Monday Schedule:Day Name + HtgSetp Default Schedule 1, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 1, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 1, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 1, !- Friday Schedule:Day Name + HtgSetp Default Schedule 1, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 1, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 1, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 1, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 1, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 1, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 1 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 1, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 1, !- Monday Schedule:Day Name + ClgSetp Default Schedule 1, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 1, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 1, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 1, !- Friday Schedule:Day Name + ClgSetp Default Schedule 1, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 1, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 1, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 1, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 1, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 1; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 1, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 1 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 1, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 2 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 2 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 2, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 2, !- Monday Schedule:Day Name + HtgSetp Default Schedule 2, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 2, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 2, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 2, !- Friday Schedule:Day Name + HtgSetp Default Schedule 2, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 2, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 2, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 2, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 2, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 2, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 2 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 2, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 2, !- Monday Schedule:Day Name + ClgSetp Default Schedule 2, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 2, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 2, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 2, !- Friday Schedule:Day Name + ClgSetp Default Schedule 2, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 2, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 2, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 2, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 2, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 2; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 2, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 2 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 2, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 3 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 3 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 3, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 3, !- Monday Schedule:Day Name + HtgSetp Default Schedule 3, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 3, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 3, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 3, !- Friday Schedule:Day Name + HtgSetp Default Schedule 3, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 3, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 3, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 3, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 3, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 3, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 3 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 3, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 3, !- Monday Schedule:Day Name + ClgSetp Default Schedule 3, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 3, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 3, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 3, !- Friday Schedule:Day Name + ClgSetp Default Schedule 3, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 3, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 3, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 3, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 3, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 3; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 3, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 3 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 3, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 4 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 4 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 4, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 4, !- Monday Schedule:Day Name + HtgSetp Default Schedule 4, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 4, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 4, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 4, !- Friday Schedule:Day Name + HtgSetp Default Schedule 4, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 4, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 4, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 4, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 4, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 4; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 4, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 4 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 4, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 4, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 4 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 4, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 4, !- Monday Schedule:Day Name + ClgSetp Default Schedule 4, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 4, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 4, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 4, !- Friday Schedule:Day Name + ClgSetp Default Schedule 4, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 4, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 4, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 4, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 4, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 4; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 4, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 4 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 4, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 5 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 5 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 5, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 5, !- Monday Schedule:Day Name + HtgSetp Default Schedule 5, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 5, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 5, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 5, !- Friday Schedule:Day Name + HtgSetp Default Schedule 5, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 5, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 5, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 5, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 5, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 5; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 5, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 5 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 5, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 5, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 5 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 5, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 5, !- Monday Schedule:Day Name + ClgSetp Default Schedule 5, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 5, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 5, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 5, !- Friday Schedule:Day Name + ClgSetp Default Schedule 5, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 5, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 5, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 5, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 5, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 5; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 5, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 5 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 5, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 5, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + +! ##################################################################################### +! thermostat info for Thermal Zone 6 +! ##################################################################################### + +! thermos heating daily schedule +Schedule:Week:Daily, + HtgSetp 6 Week Rule - Jan1-Dec31, !- Name + HtgSetp Default Schedule 6, !- Sunday Schedule:Day Name + HtgSetp Default Schedule 6, !- Monday Schedule:Day Name + HtgSetp Default Schedule 6, !- Tuesday Schedule:Day Name + HtgSetp Default Schedule 6, !- Wednesday Schedule:Day Name + HtgSetp Default Schedule 6, !- Thursday Schedule:Day Name + HtgSetp Default Schedule 6, !- Friday Schedule:Day Name + HtgSetp Default Schedule 6, !- Saturday Schedule:Day Name + HtgSetp Default Schedule 6, !- Holiday Schedule:Day Name + HtgSetp Summer Design Day 6, !- SummerDesignDay Schedule:Day Name + HtgSetp Winter Design Day 6, !- WinterDesignDay Schedule:Day Name + HtgSetp Default Schedule 6, !- CustomDay1 Schedule:Day Name + HtgSetp Default Schedule 6; !- CustomDay2 Schedule:Day Name + +! thermos heating yearly schedule +Schedule:Year, + HtgSetp 6, !- Name + Temperature 36, !- Schedule Type Limits Name + HtgSetp 6 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos heating design day schedule +Schedule:Day:Interval, + HtgSetp Summer Design Day 6, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 15.6; !- Value Until Time 1 +Schedule:Day:Interval, + HtgSetp Winter Design Day 6, !- Name + Temperature 36, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 21; + +! thermos cooling daily schedule +Schedule:Week:Daily, + ClgSetp 6 Week Rule - Jan1-Dec31, !- Name + ClgSetp Default Schedule 6, !- Sunday Schedule:Day Name + ClgSetp Default Schedule 6, !- Monday Schedule:Day Name + ClgSetp Default Schedule 6, !- Tuesday Schedule:Day Name + ClgSetp Default Schedule 6, !- Wednesday Schedule:Day Name + ClgSetp Default Schedule 6, !- Thursday Schedule:Day Name + ClgSetp Default Schedule 6, !- Friday Schedule:Day Name + ClgSetp Default Schedule 6, !- Saturday Schedule:Day Name + ClgSetp Default Schedule 6, !- Holiday Schedule:Day Name + ClgSetp Summer Design Day 6, !- SummerDesignDay Schedule:Day Name + ClgSetp Winter Design Day 6, !- WinterDesignDay Schedule:Day Name + ClgSetp Default Schedule 6, !- CustomDay1 Schedule:Day Name + ClgSetp Default Schedule 6; !- CustomDay2 Schedule:Day Name + +! thermos cooling yearly schedule +Schedule:Year, + ClgSetp 6, !- Name + Temperature 37, !- Schedule Type Limits Name + ClgSetp 6 Week Rule - Jan1-Dec31, !- Schedule:Week Name 1 + 1, !- Start Month 1 + 1, !- Start Day 1 + 12, !- End Month 1 + 31; !- End Day 1 + +! thermos cooling design day schedule +Schedule:Day:Interval, + ClgSetp Summer Design Day 6, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 06:00, !- Time 1 hh:mm + 26.7, !- Value Until Time 1 + 22:00, !- Time 2 hh:mm + 24, !- Value Until Time 2 + 24:00, !- Time 3 hh:mm + 26.7; !- Value Until Time 3 +Schedule:Day:Interval, + ClgSetp Winter Design Day 6, !- Name + Temperature 37, !- Schedule Type Limits Name + No, !- Interpolate to Timestep + 24:00, !- Time 1 hh:mm + 26.7; + + +Schedule:Day:Interval, + ClgSetp Default Schedule 1, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 1, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 2, + Temperature 37, + No, + 01:00, 28.3, !- Value Until Time + 02:00, 28.3, !- Value Until Time + 03:00, 28.3, !- Value Until Time + 04:00, 28.3, !- Value Until Time + 05:00, 28.3, !- Value Until Time + 06:00, 28.3, !- Value Until Time + 07:00, 28.3, !- Value Until Time + 08:00, 28.3, !- Value Until Time + 09:00, 26.2, !- Value Until Time + 10:00, 26.2, !- Value Until Time + 11:00, 26.2, !- Value Until Time + 12:00, 26.2, !- Value Until Time + 13:00, 26.2, !- Value Until Time + 14:00, 26.2, !- Value Until Time + 15:00, 26.2, !- Value Until Time + 16:00, 26.2, !- Value Until Time + 17:00, 26.2, !- Value Until Time + 18:00, 26.2, !- Value Until Time + 19:00, 28.3, !- Value Until Time + 20:00, 28.3, !- Value Until Time + 21:00, 28.3, !- Value Until Time + 22:00, 28.3, !- Value Until Time + 23:00, 28.3, !- Value Until Time + 24:00, 28.3; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 2, + Temperature 36, + No, + 01:00, 22.1, !- Value Until Time + 02:00, 22.1, !- Value Until Time + 03:00, 22.1, !- Value Until Time + 04:00, 22.1, !- Value Until Time + 05:00, 22.1, !- Value Until Time + 06:00, 22.1, !- Value Until Time + 07:00, 22.1, !- Value Until Time + 08:00, 22.1, !- Value Until Time + 09:00, 20.3, !- Value Until Time + 10:00, 20.3, !- Value Until Time + 11:00, 20.3, !- Value Until Time + 12:00, 20.3, !- Value Until Time + 13:00, 20.3, !- Value Until Time + 14:00, 20.3, !- Value Until Time + 15:00, 20.3, !- Value Until Time + 16:00, 20.3, !- Value Until Time + 17:00, 20.3, !- Value Until Time + 18:00, 20.3, !- Value Until Time + 19:00, 22.1, !- Value Until Time + 20:00, 22.1, !- Value Until Time + 21:00, 22.1, !- Value Until Time + 22:00, 22.1, !- Value Until Time + 23:00, 22.1, !- Value Until Time + 24:00, 22.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 3, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 3, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 4, + Temperature 37, + No, + 01:00, 28.4, !- Value Until Time + 02:00, 28.4, !- Value Until Time + 03:00, 28.4, !- Value Until Time + 04:00, 28.4, !- Value Until Time + 05:00, 28.4, !- Value Until Time + 06:00, 28.4, !- Value Until Time + 07:00, 28.4, !- Value Until Time + 08:00, 28.4, !- Value Until Time + 09:00, 24.2, !- Value Until Time + 10:00, 24.2, !- Value Until Time + 11:00, 24.2, !- Value Until Time + 12:00, 24.2, !- Value Until Time + 13:00, 24.2, !- Value Until Time + 14:00, 24.2, !- Value Until Time + 15:00, 28.4, !- Value Until Time + 16:00, 28.4, !- Value Until Time + 17:00, 28.4, !- Value Until Time + 18:00, 28.4, !- Value Until Time + 19:00, 28.4, !- Value Until Time + 20:00, 28.4, !- Value Until Time + 21:00, 28.4, !- Value Until Time + 22:00, 28.4, !- Value Until Time + 23:00, 28.4, !- Value Until Time + 24:00, 28.4; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 4, + Temperature 36, + No, + 01:00, 23.1, !- Value Until Time + 02:00, 23.1, !- Value Until Time + 03:00, 23.1, !- Value Until Time + 04:00, 23.1, !- Value Until Time + 05:00, 23.1, !- Value Until Time + 06:00, 23.1, !- Value Until Time + 07:00, 23.1, !- Value Until Time + 08:00, 23.1, !- Value Until Time + 09:00, 21.9, !- Value Until Time + 10:00, 21.9, !- Value Until Time + 11:00, 21.9, !- Value Until Time + 12:00, 21.9, !- Value Until Time + 13:00, 21.9, !- Value Until Time + 14:00, 21.9, !- Value Until Time + 15:00, 23.1, !- Value Until Time + 16:00, 23.1, !- Value Until Time + 17:00, 23.1, !- Value Until Time + 18:00, 23.1, !- Value Until Time + 19:00, 23.1, !- Value Until Time + 20:00, 23.1, !- Value Until Time + 21:00, 23.1, !- Value Until Time + 22:00, 23.1, !- Value Until Time + 23:00, 23.1, !- Value Until Time + 24:00, 23.1; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 5, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 5, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + + +Schedule:Day:Interval, + ClgSetp Default Schedule 6, + Temperature 37, + No, + 01:00, 28.7, !- Value Until Time + 02:00, 28.7, !- Value Until Time + 03:00, 28.7, !- Value Until Time + 04:00, 28.7, !- Value Until Time + 05:00, 28.7, !- Value Until Time + 06:00, 28.7, !- Value Until Time + 07:00, 25.7, !- Value Until Time + 08:00, 25.7, !- Value Until Time + 09:00, 25.7, !- Value Until Time + 10:00, 25.7, !- Value Until Time + 11:00, 25.7, !- Value Until Time + 12:00, 25.7, !- Value Until Time + 13:00, 25.7, !- Value Until Time + 14:00, 25.7, !- Value Until Time + 15:00, 25.7, !- Value Until Time + 16:00, 25.7, !- Value Until Time + 17:00, 25.7, !- Value Until Time + 18:00, 25.7, !- Value Until Time + 19:00, 25.7, !- Value Until Time + 20:00, 25.7, !- Value Until Time + 21:00, 28.7, !- Value Until Time + 22:00, 28.7, !- Value Until Time + 23:00, 28.7, !- Value Until Time + 24:00, 28.7; !- Value Until Time + + +Schedule:Day:Interval, + HtgSetp Default Schedule 6, + Temperature 36, + No, + 01:00, 22.2, !- Value Until Time + 02:00, 22.2, !- Value Until Time + 03:00, 22.2, !- Value Until Time + 04:00, 22.2, !- Value Until Time + 05:00, 22.2, !- Value Until Time + 06:00, 22.2, !- Value Until Time + 07:00, 19.0, !- Value Until Time + 08:00, 19.0, !- Value Until Time + 09:00, 19.0, !- Value Until Time + 10:00, 19.0, !- Value Until Time + 11:00, 19.0, !- Value Until Time + 12:00, 19.0, !- Value Until Time + 13:00, 19.0, !- Value Until Time + 14:00, 19.0, !- Value Until Time + 15:00, 19.0, !- Value Until Time + 16:00, 19.0, !- Value Until Time + 17:00, 19.0, !- Value Until Time + 18:00, 19.0, !- Value Until Time + 19:00, 19.0, !- Value Until Time + 20:00, 19.0, !- Value Until Time + 21:00, 22.2, !- Value Until Time + 22:00, 22.2, !- Value Until Time + 23:00, 22.2, !- Value Until Time + 24:00, 22.2; !- Value Until Time + + +! ==================================== Execution 2 Successful ==================================== +! ==================================== Execution 3 Started ==================================== + +ZoneTerminalUnitList, + VRF System Terminal List, !- Zone Terminal Unit List Name + VRF Zone Terminal 1, + VRF Zone Terminal 2, + VRF Zone Terminal 3, + VRF Zone Terminal 4, + VRF Zone Terminal 5, + VRF Zone Terminal 6; + +ZoneControl:Thermostat, + Thermal Zone 1 Thermostat, !- Name + Thermal Zone 1, !- Zone or ZoneList Name + Thermal Zone 1 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 1, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 1 Thermostat Schedule, !- Name + Thermal Zone 1 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 1 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 1, !- Name + HtgSetp 1, !- Heating Setpoint Temperature Schedule Name + ClgSetp 1; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 1, !- Zone Name + Thermal Zone 1 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 1 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 1 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 1; !- Zone Air Node Name + +NodeList, + Thermal Zone 1 Inlet Node List, !- Name + Node Air Thermal Zone 1 In; !- Node Name 1 + +NodeList, + Thermal Zone 1 Exhaust Node List, !- Name + Node Air Thermal Zone 1 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 1, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 1 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 1 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 1, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 1 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 1, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 1, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 1 OA Mixer, !- Name + VRF Zone Terminal 1 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 1 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 1 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 1 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 1 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 1, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 1 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 1 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 1, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 1 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 1 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 1, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 1 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 1 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 1 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 1, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 1, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 1, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 1, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 2 Thermostat, !- Name + Thermal Zone 2, !- Zone or ZoneList Name + Thermal Zone 2 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 2, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 2 Thermostat Schedule, !- Name + Thermal Zone 2 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 2 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 2, !- Name + HtgSetp 2, !- Heating Setpoint Temperature Schedule Name + ClgSetp 2; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 2, !- Zone Name + Thermal Zone 2 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 2 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 2 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 2; !- Zone Air Node Name + +NodeList, + Thermal Zone 2 Inlet Node List, !- Name + Node Air Thermal Zone 2 In; !- Node Name 1 + +NodeList, + Thermal Zone 2 Exhaust Node List, !- Name + Node Air Thermal Zone 2 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 2, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 2 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 2 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 2, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 2 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 2, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 2, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 2 OA Mixer, !- Name + VRF Zone Terminal 2 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 2 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 2 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 2 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 2 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 2, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 2 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 2 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 2, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 2 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 2 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 2, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 2 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 2 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 2 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 2, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 2, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 2, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 2, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 3 Thermostat, !- Name + Thermal Zone 3, !- Zone or ZoneList Name + Thermal Zone 3 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 3, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 3 Thermostat Schedule, !- Name + Thermal Zone 3 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 3 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 3, !- Name + HtgSetp 3, !- Heating Setpoint Temperature Schedule Name + ClgSetp 3; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 3, !- Zone Name + Thermal Zone 3 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 3 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 3 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 3; !- Zone Air Node Name + +NodeList, + Thermal Zone 3 Inlet Node List, !- Name + Node Air Thermal Zone 3 In; !- Node Name 1 + +NodeList, + Thermal Zone 3 Exhaust Node List, !- Name + Node Air Thermal Zone 3 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 3, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 3 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 3 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 3, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 3 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 3, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 3, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 3 OA Mixer, !- Name + VRF Zone Terminal 3 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 3 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 3 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 3 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 3 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 3, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 3 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 3 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 3, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 3 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 3 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 3, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 3 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 3 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 3 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 3, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 3, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 3, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 3, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 4 Thermostat, !- Name + Thermal Zone 4, !- Zone or ZoneList Name + Thermal Zone 4 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 4, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 4 Thermostat Schedule, !- Name + Thermal Zone 4 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 4 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 4, !- Name + HtgSetp 4, !- Heating Setpoint Temperature Schedule Name + ClgSetp 4; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 4, !- Zone Name + Thermal Zone 4 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 4 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 4 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 4; !- Zone Air Node Name + +NodeList, + Thermal Zone 4 Inlet Node List, !- Name + Node Air Thermal Zone 4 In; !- Node Name 1 + +NodeList, + Thermal Zone 4 Exhaust Node List, !- Name + Node Air Thermal Zone 4 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 4, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 4 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 4 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 4, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 4 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 4, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 4, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 4 OA Mixer, !- Name + VRF Zone Terminal 4 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 4 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 4 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 4 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 4 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 4, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 4 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 4 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 4, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 4 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 4 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 4, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 4 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 4 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 4 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 4, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 4, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 4, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 4, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 5 Thermostat, !- Name + Thermal Zone 5, !- Zone or ZoneList Name + Thermal Zone 5 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 5, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 5 Thermostat Schedule, !- Name + Thermal Zone 5 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 5 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 5, !- Name + HtgSetp 5, !- Heating Setpoint Temperature Schedule Name + ClgSetp 5; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 5, !- Zone Name + Thermal Zone 5 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 5 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 5 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 5; !- Zone Air Node Name + +NodeList, + Thermal Zone 5 Inlet Node List, !- Name + Node Air Thermal Zone 5 In; !- Node Name 1 + +NodeList, + Thermal Zone 5 Exhaust Node List, !- Name + Node Air Thermal Zone 5 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 5, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 5 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 5 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 5, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 5 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 5, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 5, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 5 OA Mixer, !- Name + VRF Zone Terminal 5 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 5 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 5 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 5 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 5 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 5, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 5 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 5 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 5, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 5 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 5 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 5, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 5 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 5 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 5 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 5, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 5, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 5, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 5, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +ZoneControl:Thermostat, + Thermal Zone 6 Thermostat, !- Name + Thermal Zone 6, !- Zone or ZoneList Name + Thermal Zone 6 Thermostat Schedule, !- Control Type Schedule Name + ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type + Thermostat Setpoint Dual Setpoint 6, !- Control 1 Name + , !- Control 2 Object Type + , !- Control 2 Name + , !- Control 3 Object Type + , !- Control 3 Name + , !- Control 4 Object Type + , !- Control 4 Name + 0; !- Temperature Difference Between Cutout And Setpoint deltaC + +Schedule:Compact, + Thermal Zone 6 Thermostat Schedule, !- Name + Thermal Zone 6 Thermostat Schedule Type Limits, !- Schedule Type Limits Name + Through: 12/31, !- Field 1 + For: AllDays, !- Field 2 + Until: 24:00, !- Field 3 + 4; !- Field 4 + +ScheduleTypeLimits, + Thermal Zone 6 Thermostat Schedule Type Limits, !- Name + 0, !- Lower Limit Value + 4, !- Upper Limit Value + DISCRETE; !- Numeric Type + +ThermostatSetpoint:DualSetpoint, + Thermostat Setpoint Dual Setpoint 6, !- Name + HtgSetp 6, !- Heating Setpoint Temperature Schedule Name + ClgSetp 6; !- Cooling Setpoint Temperature Schedule Name + +ZoneHVAC:EquipmentConnections, + Thermal Zone 6, !- Zone Name + Thermal Zone 6 Equipment List, !- Zone Conditioning Equipment List Name + Thermal Zone 6 Inlet Node List, !- Zone Air Inlet Node or NodeList Name + Thermal Zone 6 Exhaust Node List, !- Zone Air Exhaust Node or NodeList Name + Node 6; !- Zone Air Node Name + +NodeList, + Thermal Zone 6 Inlet Node List, !- Name + Node Air Thermal Zone 6 In; !- Node Name 1 + +NodeList, + Thermal Zone 6 Exhaust Node List, !- Name + Node Air Thermal Zone 6 Out; !- Node Name 1 + +ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, + VRF Zone Terminal 6, !- Zone Terminal Unit Name + Always On Discrete hvac_library, !- Terminal Unit Availability Schedule + Node Air Thermal Zone 6 Out, !- Terminal Unit Air Inlet Node Name + Node Air Thermal Zone 6 In, !- Terminal Unit Air Outlet Node Name + Autosize, !- Cooling Supply Air Flow Rate m3/s + Autosize, !- No Cooling Supply Air Flow Rate m3/s + Autosize, !- Heating Supply Air Flow Rate m3/s + Autosize, !- No Heating Supply Air Flow Rate m3/s + Autosize, !- Cooling Outdoor Air Flow Rate m3/s + Autosize, !- Heating Outdoor Air Flow Rate m3/s + Autosize, !- No Load Outdoor Air Flow Rate m3/s + Always On Discrete hvac_library, !- Supply Air Fan Operating Mode Schedule Name + DrawThrough, !- Supply Air Fan Placement + Fan:OnOff, !- Supply Air Fan Object Type + VRF Zone Terminal Fan 6, !- Supply Air Fan Object Name + OutdoorAir:Mixer, !- Outside Air Mixer Object Type + VRF Zone Terminal 6 OA Mixer, !- Outside Air Mixer Object Name + Coil:Cooling:DX:VariableRefrigerantFlow, !- Cooling Coil Object Type + VRF Zone Terminal Cooling Coil 6, !- Cooling Coil Object Name + Coil:Heating:DX:VariableRefrigerantFlow, !- Heating Coil Object Type + VRF Zone Terminal Heating Coil 6, !- Heating Coil Object Name + 30, !- Zone Terminal Unit On Parasitic Electric Energy Use W + 20, !- Zone Terminal Unit Off Parasitic Electric Energy Use W + 1, !- Rated Heating Capacity Sizing Ratio W/W + , !- Availability Manager List Name + , !- Design Specification ZoneHVAC Sizing Object Name + , !- Supplemental Heating Coil Object Type + , !- Supplemental Heating Coil Name + , !- Maximum Supply Air Temperature from Supplemental Heater C + 6.58436560976697e-312; !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation C + +OutdoorAir:Mixer, + VRF Zone Terminal 6 OA Mixer, !- Name + VRF Zone Terminal 6 Mixer Outlet Node, !- Mixed Air Node Name + VRF Zone Terminal 6 Outdoor Air Node, !- Outdoor Air Stream Node Name + VRF Zone Terminal 6 Relief Node Name, !- Relief Air Stream Node Name + Node Air Thermal Zone 6 Out; !- Return Air Stream Node Name + +OutdoorAir:NodeList, + VRF Zone Terminal 6 Outdoor Air Node; !- Node or NodeList Name 1 + +Coil:Cooling:DX:VariableRefrigerantFlow, + VRF Zone Terminal Cooling Coil 6, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + Autosize, !- Gross Rated Total Cooling Capacity W + Autosize, !- Gross Rated Sensible Heat Ratio + Autosize, !- Rated Air Flow Rate m3/s + VRFTUCoolCapFT, !- Cooling Capacity Ratio Modifier Function of Temperature Curve Name + VRFACCoolCapFFF, !- Cooling Capacity Modifier Curve Function of Flow Fraction Name + VRF Zone Terminal 6 Mixer Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 6 Cooling Coil Outlet Node; !- Coil Air Outlet Node + +Coil:Heating:DX:VariableRefrigerantFlow, + VRF Zone Terminal Heating Coil 6, !- Name + Always On Discrete hvac_library, !- Availability Schedule + Autosize, !- Gross Rated Heating Capacity W + Autosize, !- Rated Air Flow Rate m3/s + VRF Zone Terminal 6 Cooling Coil Outlet Node, !- Coil Air Inlet Node + VRF Zone Terminal 6 Heating Coil Outlet Node, !- Coil Air Outlet Node + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Heating Capacity Ratio Modifier Function of Temperature Curve Name + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF; !- Heating Capacity Modifier Function of Flow Fraction Curve Name + +Fan:OnOff, + VRF Zone Terminal Fan 6, !- Name + Always On Discrete hvac_library, !- Availability Schedule Name + 0.78, !- Fan Total Efficiency + 1886, !- Pressure Rise Pa + Autosize, !- Maximum Flow Rate m3/s + 0.8, !- Motor Efficiency + 1, !- Motor In Airstream Fraction + VRF Zone Terminal 6 Heating Coil Outlet Node, !- Air Inlet Node Name + Node Air Thermal Zone 6 In, !- Air Outlet Node Name + Fan On Off Power Curve 19, !- Fan Power Ratio Function of Speed Ratio Curve Name + Fan On Off Efficiency Curve 6, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name + General; !- End-Use Subcategory + +ZoneHVAC:EquipmentList, + Thermal Zone 6 Equipment List, !- Name + SequentialLoad, !- Load Distribution Scheme + ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, !- Zone Equipment Object Type 1 + VRF Zone Terminal 6, !- Zone Equipment Name 1 + 1, !- Zone Equipment Cooling Sequence 1 + 1, !- Zone Equipment Heating or No-Load Sequence 1 + , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1 + ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1 + +Sizing:Zone, + Thermal Zone 6, !- Zone or ZoneList Name + SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method + 13.8, !- Zone Cooling Design Supply Air Temperature C + 11.11, !- Zone Cooling Design Supply Air Temperature Difference deltaC + SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method + 47.1, !- Zone Heating Design Supply Air Temperature C + 11.11, !- Zone Heating Design Supply Air Temperature Difference deltaC + 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio kgWater/kgDryAir + 0.008, !- Zone Heating Design Supply Air Humidity Ratio kgWater/kgDryAir + Ventilation 6, !- Design Specification Outdoor Air Object Name + , !- Zone Heating Sizing Factor + , !- Zone Cooling Sizing Factor + DesignDay, !- Cooling Design Air Flow Method + 0, !- Cooling Design Air Flow Rate m3/s + 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area m3/s-m2 + 0, !- Cooling Minimum Air Flow m3/s + 0, !- Cooling Minimum Air Flow Fraction + DesignDay, !- Heating Design Air Flow Method + 0, !- Heating Design Air Flow Rate m3/s + 0.002032, !- Heating Maximum Air Flow per Zone Floor Area m3/s-m2 + 0.1415762, !- Heating Maximum Air Flow m3/s + 0.3, !- Heating Maximum Air Flow Fraction + , !- Design Specification Zone Air Distribution Object Name + No; !- Account for Dedicated Outdoor Air System + +DesignSpecification:OutdoorAir, + Ventilation 6, !- Name + Sum, !- Outdoor Air Method + 0, !- Outdoor Air Flow per Person m3/s-person + 0, !- Outdoor Air Flow per Zone Floor Area m3/s-m2 + 0, !- Outdoor Air Flow per Zone m3/s + 2.56; !- Outdoor Air Flow Air Changes per Hour 1/hr + +AirConditioner:VariableRefrigerantFlow, + VRF System, !- Heat Pump Name + Always On Discrete hvac_library, !- Availability Schedule Name + 26976, !- Gross Rated Total Cooling Capacity W + 4.23, !- Gross Rated Cooling COP W/W + -5, !- Minimum Condenser Inlet Node Temperature in Cooling Mode C + 43, !- Maximum Condenser Inlet Node Temperature in Cooling Mode C + VRF System VRFCoolCapFT 1, !- Cooling Capacity Ratio Modifier Function of Low Temperature Curve Name + VRF System VRFCoolCapFTBoundary 1, !- Cooling Capacity Ratio Boundary Curve Name + VRF System VRFCoolCapFTHi 1, !- Cooling Capacity Ratio Modifier Function of High Temperature Curve Name + VRF System VRFCoolEIRFT 1, !- Cooling Energy Input Ratio Modifier Function of Low Temperature Curve Name + VRF System VRFCoolEIRFTBoundary 1, !- Cooling Energy Input Ratio Boundary Curve Name + VRF System VRFCoolEIRFTHi 1, !- Cooling Energy Input Ratio Modifier Function of High Temperature Curve Name + VRF System CoolingEIRLowPLR 1, !- Cooling Energy Input Ratio Modifier Function of Low Part-Load Ratio Curve Name + VRF System CoolingEIRHiPLR 1, !- Cooling Energy Input Ratio Modifier Function of High Part-Load Ratio Curve Name + VRF System CoolingCombRatio 1, !- Cooling Combination Ratio Correction Factor Curve Name + VRF System VRFCPLFFPLR 1, !- Cooling Part-Load Fraction Correlation Curve Name + 28118, !- Gross Rated Heating Capacity W + 1, !- Rated Heating Capacity Sizing Ratio W/W + 4.95, !- Gross Rated Heating COP W/W + -20, !- Minimum Condenser Inlet Node Temperature in Heating Mode C + 30, !- Maximum Condenser Inlet Node Temperature in Heating Mode C + VRF System VRFHeatCapFT 1, !- Heating Capacity Ratio Modifier Function of Low Temperature Curve Name + VRF System VRFHeatCapFTBoundary 1, !- Heating Capacity Ratio Boundary Curve Name + VRF System VRFHeatCapFTHi 1, !- Heating Capacity Ratio Modifier Function of High Temperature Curve Name + VRF System VRFHeatEIRFT 1, !- Heating Energy Input Ratio Modifier Function of Low Temperature Curve Name + VRF System VRFHeatEIRFTBoundary 1, !- Heating Energy Input Ratio Boundary Curve Name + VRF System VRFHeatEIRFTHi 1, !- Heating Energy Input Ratio Modifier Function of High Temperature Curve Name + WetBulbTemperature, !- Heating Performance Curve Outdoor Temperature Type + VRF System HeatingEIRLowPLR 1, !- Heating Energy Input Ratio Modifier Function of Low Part-Load Ratio Curve Name + VRF System HeatingEIRHiPLR 1, !- Heating Energy Input Ratio Modifier Function of High Part-Load Ratio Curve Name + VRF System HeatingCombRatio 1, !- Heating Combination Ratio Correction Factor Curve Name + VRF System VRFCPLFFPLR 2, !- Heating Part-Load Fraction Correlation Curve Name + 0.5, !- Minimum Heat Pump Part-Load Ratio dimensionless + , !- Zone Name for Master Thermostat Location + LoadPriority, !- Master Thermostat Priority Control Type + , !- Thermostat Priority Schedule Name + VRF System Terminal List, !- Zone Terminal Unit List Name + No, !- Heat Pump Waste Heat Recovery + 30, !- Equivalent Piping Length used for Piping Correction Factor in Cooling Mode m + 10, !- Vertical Height used for Piping Correction Factor m + VRF System CoolingLengthCorrectionFactor 1, !- Piping Correction Factor for Length in Cooling Mode Curve Name + -0.000386, !- Piping Correction Factor for Height in Cooling Mode Coefficient 1/m + 30, !- Equivalent Piping Length used for Piping Correction Factor in Heating Mode m + VRF System HeatingLengthCorrectionFactor 1, !- Piping Correction Factor for Length in Heating Mode Curve Name + 0, !- Piping Correction Factor for Height in Heating Mode Coefficient 1/m + 15, !- Crankcase Heater Power per Compressor W + 3, !- Number of Compressors dimensionless + 0.33, !- Ratio of Compressor Size to Total Compressor Capacity W/W + 7, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater C + Resistive, !- Defrost Strategy + Timed, !- Defrost Control + , !- Defrost Energy Input Ratio Modifier Function of Temperature Curve Name + 0.058333, !- Defrost Time Period Fraction dimensionless + 1e-07, !- Resistive Defrost Heater Capacity W + 7, !- Maximum Outdoor Dry-bulb Temperature for Defrost Operation C + AirCooled, !- Condenser Type + , !- Condenser Inlet Node Name + , !- Condenser Outlet Node Name + Autosize, !- Water Condenser Volume Flow Rate m3/s + 0.9, !- Evaporative Condenser Effectiveness dimensionless + Autosize, !- Evaporative Condenser Air Flow Rate m3/s + Autosize, !- Evaporative Condenser Pump Rated Power Consumption W + , !- Supply Water Storage Tank Name + 0, !- Basin Heater Capacity W/K + 2, !- Basin Heater Setpoint Temperature C + , !- Basin Heater Operating Schedule Name + Electricity, !- Fuel Type + 0, !- Minimum Condenser Inlet Node Temperature in Heat Recovery Mode C + 30, !- Maximum Condenser Inlet Node Temperature in Heat Recovery Mode C + VRF System Heat Recovery Cooling Cap Modifier 1, !- Heat Recovery Cooling Capacity Modifier Curve Name + 1, !- Initial Heat Recovery Cooling Capacity Fraction W/W + 0.083, !- Heat Recovery Cooling Capacity Time Constant hr + VRF System Heat Recovery Cooling Energy Modifier 1, !- Heat Recovery Cooling Energy Modifier Curve Name + 1, !- Initial Heat Recovery Cooling Energy Fraction W/W + 0, !- Heat Recovery Cooling Energy Time Constant hr + VRF System Heat Recovery Heating Cap Modifier 1, !- Heat Recovery Heating Capacity Modifier Curve Name + 0.5, !- Initial Heat Recovery Heating Capacity Fraction W/W + 0.083, !- Heat Recovery Heating Capacity Time Constant hr + VRF System Heat Recovery Heating Energy Modifier 1, !- Heat Recovery Heating Energy Modifier Curve Name + 0.5, !- Initial Heat Recovery Heating Energy Fraction W/W + 0; !- Heat Recovery Heating Energy Time Constant hr + +! vrf curve +Curve:Biquadratic, + VRF System VRFCoolCapFT 1, !- Name + 0.576882692, !- Coefficient1 Constant + 0.017447952, !- Coefficient2 x + 0.000583269, !- Coefficient3 x**2 + -1.76324e-06, !- Coefficient4 y + -7.474e-09, !- Coefficient5 y**2 + -1.30413e-07, !- Coefficient6 x*y + 15, !- Minimum Value of x + 24, !- Maximum Value of x + -5, !- Minimum Value of y + 23, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFCoolCapFTBoundary 1, !- Name + 25.73, !- Coefficient1 Constant + -0.03150043, !- Coefficient2 x + -0.01416595, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 11, !- Minimum Value of x + 30, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFCoolCapFTHi 1, !- Name + 0.6867358, !- Coefficient1 Constant + 0.0207631, !- Coefficient2 x + 0.0005447, !- Coefficient3 x**2 + -0.0016218, !- Coefficient4 y + -4.259e-07, !- Coefficient5 y**2 + -0.0003392, !- Coefficient6 x*y + 15, !- Minimum Value of x + 24, !- Maximum Value of x + 16, !- Minimum Value of y + 43, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFCoolEIRFT 1, !- Name + 0.989010541, !- Coefficient1 Constant + -0.02347967, !- Coefficient2 x + 0.000199711, !- Coefficient3 x**2 + 0.005968336, !- Coefficient4 y + -1.0289e-07, !- Coefficient5 y**2 + -0.00015686, !- Coefficient6 x*y + 15, !- Minimum Value of x + 24, !- Maximum Value of x + -5, !- Minimum Value of y + 23, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFCoolEIRFTBoundary 1, !- Name + 25.73473775, !- Coefficient1 Constant + -0.03150043, !- Coefficient2 x + -0.01416595, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 15, !- Minimum Value of x + 24, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFCoolEIRFTHi 1, !- Name + -1.4395110176, !- Coefficient1 Constant + 0.1619850459, !- Coefficient2 x + -0.0034911781, !- Coefficient3 x**2 + 0.0269442645, !- Coefficient4 y + 0.0001346163, !- Coefficient5 y**2 + -0.0006714941, !- Coefficient6 x*y + 15, !- Minimum Value of x + 23.9, !- Maximum Value of x + 16.8, !- Minimum Value of y + 43.3, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System CoolingEIRLowPLR 1, !- Name + 0.4541226192, !- Coefficient1 Constant + -0.1729687081, !- Coefficient2 x + 1.0828661347, !- Coefficient3 x**2 + -0.3618480897, !- Coefficient4 x**3 + 0.5, !- Minimum Value of x + 1, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature; !- Output Unit Type + +Curve:Cubic, + VRF System CoolingEIRHiPLR 1, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1.5, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System CoolingCombRatio 1, !- Name + 0.576593263, !- Coefficient1 Constant + 0.6349408697, !- Coefficient2 x + -0.3076093963, !- Coefficient3 x**2 + 0.0960752636, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1.5, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFCPLFFPLR 1, !- Name + 0.85, !- Coefficient1 Constant + 0.15, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFHeatCapFT 1, !- Name + 1.012090154, !- Coefficient1 Constant + -0.0012467553, !- Coefficient2 x + -0.0001271847, !- Coefficient3 x**2 + 0.0267564328, !- Coefficient4 y + -4.986e-07, !- Coefficient5 y**2 + -0.0002635239, !- Coefficient6 x*y + 21.1, !- Minimum Value of x + 27.2, !- Maximum Value of x + -20, !- Minimum Value of y + 3.33, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFHeatCapFTBoundary 1, !- Name + 58.577, !- Coefficient1 Constant + -3.0255, !- Coefficient2 x + 0.0193, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 15, !- Minimum Value of x + 23.9, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFHeatCapFTHi 1, !- Name + 2.5859872368, !- Coefficient1 Constant + -0.0953227101, !- Coefficient2 x + 0.0009553288, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 21.1, !- Minimum Value of x + 27.2, !- Maximum Value of x + -9.44, !- Minimum Value of y + 15, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFHeatEIRFT 1, !- Name + 0.7224292683, !- Coefficient1 Constant + 0.0034566628, !- Coefficient2 x + 0.0006507028, !- Coefficient3 x**2 + -0.0026435362, !- Coefficient4 y + 0.0012464766, !- Coefficient5 y**2 + -0.0001009161, !- Coefficient6 x*y + 21.1, !- Minimum Value of x + 27.2, !- Maximum Value of x + -20, !- Minimum Value of y + 3.33, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFHeatEIRFTBoundary 1, !- Name + 58.577, !- Coefficient1 Constant + -3.0255, !- Coefficient2 x + 0.0193, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 15, !- Minimum Value of x + 23.9, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature; !- Output Unit Type + +Curve:Biquadratic, + VRF System VRFHeatEIRFTHi 1, !- Name + 1.3885703646, !- Coefficient1 Constant + -0.0229771462, !- Coefficient2 x + 0.000537274, !- Coefficient3 x**2 + -0.0273936962, !- Coefficient4 y + 0.0004030426, !- Coefficient5 y**2 + -5.9786e-05, !- Coefficient6 x*y + 21.1, !- Minimum Value of x + 27.2, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System HeatingEIRLowPLR 1, !- Name + 0.3924742025, !- Coefficient1 Constant + 0.076016374, !- Coefficient2 x + 0.6983235783, !- Coefficient3 x**2 + -0.1688407813, !- Coefficient4 x**3 + 0.5, !- Minimum Value of x + 1, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System HeatingEIRHiPLR 1, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1.5, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System HeatingCombRatio 1, !- Name + 0.7667196604, !- Coefficient1 Constant + 0.2617302019, !- Coefficient2 x + -0.0159110245, !- Coefficient3 x**2 + -0.0125388376, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1.5, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Cubic, + VRF System VRFCPLFFPLR 2, !- Name + 0.85, !- Coefficient1 Constant + 0.15, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 1, !- Minimum Value of x + 1, !- Maximum Value of x + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System CoolingLengthCorrectionFactor 1, !- Name + 2.0388158625, !- Coefficient1 Constant + -0.0024260645, !- Coefficient2 x + 3.5512e-06, !- Coefficient3 x**2 + -1.6858129772, !- Coefficient4 y + 0.668703358, !- Coefficient5 y**2 + -4.5706e-05, !- Coefficient6 x*y + 7.62, !- Minimum Value of x + 182.88, !- Maximum Value of x + 0.8, !- Minimum Value of y + 1.5, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System HeatingLengthCorrectionFactor 1, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 0, !- Minimum Value of x + 1, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System Heat Recovery Cooling Cap Modifier 1, !- Name + 0.9, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 0, !- Minimum Value of x + 1, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System Heat Recovery Cooling Energy Modifier 1, !- Name + 1.1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 0, !- Minimum Value of x + 1, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System Heat Recovery Heating Cap Modifier 1, !- Name + 0.9, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 0, !- Minimum Value of x + 1, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRF System Heat Recovery Heating Energy Modifier 1, !- Name + 1.1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 y + 0, !- Coefficient5 y**2 + 0, !- Coefficient6 x*y + 0, !- Minimum Value of x + 1, !- Maximum Value of x + 0, !- Minimum Value of y + 1, !- Maximum Value of y + , !- Minimum Curve Output + , !- Maximum Curve Output + Dimensionless, !- Input Unit Type for X + Dimensionless, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Biquadratic, + VRFTUCoolCapFT, !- Name + 0.0585884077803259, !- Coefficient1 Constant + 0.0587396532718384, !- Coefficient2 x + -0.000210274979759697, !- Coefficient3 x**2 + 0.0109370473889647, !- Coefficient4 y + -0.0001219549, !- Coefficient5 y**2 + -0.0005246615, !- Coefficient6 x*y + 15, !- Minimum Value of x + 23.89, !- Maximum Value of x + 20, !- Minimum Value of y + 43.33, !- Maximum Value of y + 0.8083, !- Minimum Curve Output + 1.2583, !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Quadratic, + VRFACCoolCapFFF, !- Name + 0.8, !- Coefficient1 Constant + 0.2, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0.5, !- Minimum Value of x + 1.5; !- Maximum Value of x + +Curve:Biquadratic, + Coil Heating DX Variable Refrigerant Flow 1 VRFTUHeatCAPFT, !- Name + 0.375443994956127, !- Coefficient1 Constant + 0.0668190645147821, !- Coefficient2 x + -0.00194171026482001, !- Coefficient3 x**2 + 0.0442618420640187, !- Coefficient4 y + -0.0004009578, !- Coefficient5 y**2 + -0.0014819801, !- Coefficient6 x*y + 21.11, !- Minimum Value of x + 27.22, !- Maximum Value of x + -15, !- Minimum Value of y + 18.33, !- Maximum Value of y + 0.6074, !- Minimum Curve Output + 1, !- Maximum Curve Output + Temperature, !- Input Unit Type for X + Temperature, !- Input Unit Type for Y + Dimensionless; !- Output Unit Type + +Curve:Quadratic, + Coil Heating DX Variable Refrigerant Flow 1 VRFACCoolCapFFF, !- Name + 0.8, !- Coefficient1 Constant + 0.2, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0.5, !- Minimum Value of x + 1.5; !- Maximum Value of x + +Curve:Exponent, + Fan On Off Power Curve 19, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 Constant + 0, !- Coefficient3 Constant + 0, !- Minimum Value of x + 1; !- Maximum Value of x + +Curve:Cubic, + Fan On Off Efficiency Curve 6, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 0, !- Minimum Value of x + 1; !- Maximum Value of x + +! ################################################################################# +! simulation setting +SimulationControl, + Yes, !- Do Zone Sizing Calculation + Yes, !- Do System Sizing Calculation + Yes, !- Do Plant Sizing Calculation + Yes, !- Run Simulation for Sizing Periods + Yes, !- Run Simulation for Weather File Run Periods + , !- Do HVAC Sizing Simulation for Sizing Periods + ; !- Maximum Number of HVAC Sizing Simulation Passes + +ConvergenceLimits, + 1; !- Minimum System Timestep + +HeatBalanceAlgorithm, + ConductionTransferFunction, !- Algorithm + 200; !- Surface Temperature Upper Limit + +RunPeriod, + Run Period 1, !- Name + 1, !- Begin Month + 1, !- Begin Day of Month + 2006, !- Begin Year + 12, !- End Month + 31, !- End Day of Month + 2006, !- End Year + Sunday, !- Day of Week for Start Day + No, !- Use Weather File Holidays and Special Days + No, !- Use Weather File Daylight Saving Period + No, !- Apply Weekend Holiday Rule + Yes, !- Use Weather File Rain Indicators + Yes; !- Use Weather File Snow Indicators + +ShadowCalculation, + PolygonClipping, !- Shading Calculation Method + Periodic, !- Shading Calculation Update Frequency Method + 20, !- Shading Calculation Update Frequency + 15000, !- Maximum Figures in Shadow Overlap Calculations + SutherlandHodgman, !- Polygon Clipping Algorithm + 512, !- Pixel Counting Resolution + SimpleSkyDiffuseModeling, !- Sky Diffuse Modeling Algorithm + No, !- Output External Shading Calculation Results + No, !- Disable Self-Shading Within Shading Zone Groups + No; !- Disable Self-Shading From Shading Zone Groups to Other Zones + +SurfaceConvectionAlgorithm:Inside, + TARP; !- Algorithm + +SurfaceConvectionAlgorithm:Outside, + DOE-2; !- Algorithm + +Sizing:Parameters, + 1.25, !- Heating Sizing Factor + 1.15; !- Cooling Sizing Factor + +ZoneAirContaminantBalance, + No; !- Carbon Dioxide Concentration + +ZoneAirHeatBalanceAlgorithm, + ThirdOrderBackwardDifference; !- Algorithm + +ZoneCapacitanceMultiplier:ResearchSpecial, + Zone Capacitance Multiplier Research Special, !- Name + , !- Zone or ZoneList Name + , !- Temperature Capacity Multiplier + , !- Humidity Capacity Multiplier + , !- Carbon Dioxide Capacity Multiplier + ; !- Generic Contaminant Capacity Multiplier + +GlobalGeometryRules, + UpperLeftCorner, !- Starting Vertex Position + Counterclockwise, !- Vertex Entry Direction + Relative, !- Coordinate System + Relative, !- Daylighting Reference Point Coordinate System + Relative; !- Rectangular Surface Coordinate System + +! ################################################################################# +! schedule type setting +ScheduleTypeLimits, + ActivityLevel, !- Name + 0, !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + activitylevel; !- Unit Type + +ScheduleTypeLimits, + ActivityLevel 13, !- Name + 0, !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + activitylevel; !- Unit Type + +ScheduleTypeLimits, + Fraction, !- Name + 0, !- Lower Limit Value + 1, !- Upper Limit Value + CONTINUOUS; !- Numeric Type + +ScheduleTypeLimits, + OnOff, !- Name + 0, !- Lower Limit Value + 1, !- Upper Limit Value + Discrete, !- Numeric Type + availability; !- Unit Type + +Schedule:Constant, + Always On Discrete, !- Name + OnOff, !- Schedule Type Limits Name + 1; !- Hourly Value + +Schedule:Constant, + Always On Discrete 1, !- Name + OnOff, !- Schedule Type Limits Name + 1; !- Hourly Value + +Schedule:Constant, + Always Off Discrete, !- Name + , !- Schedule Type Limits Name + 0; !- Hourly Value + +Schedule:Constant, + Always On Discrete hvac_library, !- Name + OnOff hvac_library, !- Schedule Type Limits Name + 1; + +Schedule:Constant, + Always On Continuous, !- Name + , !- Schedule Type Limits Name + 1; !- Hourly Value + +ScheduleTypeLimits, + Temperature 36, !- Name + , !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + temperature; !- Unit Type + +ScheduleTypeLimits, + Temperature 37, !- Name + , !- Lower Limit Value + , !- Upper Limit Value + Continuous, !- Numeric Type + temperature; !- Unit Type + +OutdoorAir:Node, + Model Outdoor Air Node; !- Name + +! ==================================== Execution 3 Successful ==================================== +! ==================================== Execution 4 Started ==================================== +! ========== Error during execution: name 'chilled_system' is not defined ========== + +ScheduleTypeLimits, + OnOff hvac_library, !- Name + 0, !- Lower Limit Value {BasedOnField A3} + 1, !- Upper Limit Value {BasedOnField A3} + Discrete, !- Numeric Type + availability; !- Unit Type + +Curve:Exponent, + Fan On Off Power Curve 12, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 Constant + 0, !- Coefficient3 Constant + 0, !- Minimum Value of x {BasedOnField A2} + 1; !- Maximum Value of x {BasedOnField A2} + +Curve:Cubic, + Fan On Off Efficiency Curve 12, !- Name + 1, !- Coefficient1 Constant + 0, !- Coefficient2 x + 0, !- Coefficient3 x**2 + 0, !- Coefficient4 x**3 + 0, !- Minimum Value of x {BasedOnField A2} + 1; !- Maximum Value of x {BasedOnField A2} + +Building, + Building 1, !- Name + -0, !- North Axis {deg} + , !- Terrain + , !- Loads Convergence Tolerance Value {W} + , !- Temperature Convergence Tolerance Value {deltaC} + , !- Solar Distribution + , !- Maximum Number of Warmup Days + ; !- Minimum Number of Warmup Days + +Version, + 9.6; !- Version Identifier + +Timestep, + 1; !- Number of Timesteps per Hour + +LifeCycleCost:Parameters, + Life Cycle Cost Parameters, !- Name + EndOfYear, !- Discounting Convention + ConstantDollar, !- Inflation Approach + 0.03, !- Real Discount Rate + , !- Nominal Discount Rate + , !- Inflation + , !- Base Date Month + 2011, !- Base Date Year + , !- Service Date Month + 2011, !- Service Date Year + 25, !- Length of Study Period in Years + , !- Tax rate + None; !- Depreciation Method + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Electricity, !- Name + Electricity, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9838, !- Year Escalation 1 + 0.9730, !- Year Escalation 2 + 0.9632, !- Year Escalation 3 + 0.9611, !- Year Escalation 4 + 0.9571, !- Year Escalation 5 + 0.9553, !- Year Escalation 6 + 0.9539, !- Year Escalation 7 + 0.9521, !- Year Escalation 8 + 0.9546, !- Year Escalation 9 + 0.9550, !- Year Escalation 10 + 0.9553, !- Year Escalation 11 + 0.9564, !- Year Escalation 12 + 0.9575, !- Year Escalation 13 + 0.9596, !- Year Escalation 14 + 0.9618, !- Year Escalation 15 + 0.9614, !- Year Escalation 16 + 0.9618, !- Year Escalation 17 + 0.9618, !- Year Escalation 18 + 0.9593, !- Year Escalation 19 + 0.9589, !- Year Escalation 20 + 0.9607, !- Year Escalation 21 + 0.9625, !- Year Escalation 22 + 0.9650, !- Year Escalation 23 + 0.9708, !- Year Escalation 24 + 0.9751, !- Year Escalation 25 + 0.9762, !- Year Escalation 26 + 0.9766, !- Year Escalation 27 + 0.9766, !- Year Escalation 28 + 0.9769, !- Year Escalation 29 + 0.9773; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Distillate Oil, !- Name + FuelOilNo1, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9714, !- Year Escalation 1 + 0.9730, !- Year Escalation 2 + 0.9942, !- Year Escalation 3 + 1.0164, !- Year Escalation 4 + 1.0541, !- Year Escalation 5 + 1.0928, !- Year Escalation 6 + 1.1267, !- Year Escalation 7 + 1.1580, !- Year Escalation 8 + 1.1792, !- Year Escalation 9 + 1.1967, !- Year Escalation 10 + 1.2200, !- Year Escalation 11 + 1.2333, !- Year Escalation 12 + 1.2566, !- Year Escalation 13 + 1.2709, !- Year Escalation 14 + 1.2826, !- Year Escalation 15 + 1.2985, !- Year Escalation 16 + 1.3102, !- Year Escalation 17 + 1.3250, !- Year Escalation 18 + 1.3261, !- Year Escalation 19 + 1.3282, !- Year Escalation 20 + 1.3324, !- Year Escalation 21 + 1.3356, !- Year Escalation 22 + 1.3431, !- Year Escalation 23 + 1.3510, !- Year Escalation 24 + 1.3568, !- Year Escalation 25 + 1.3606, !- Year Escalation 26 + 1.3637, !- Year Escalation 27 + 1.3674, !- Year Escalation 28 + 1.3706, !- Year Escalation 29 + 1.3743; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Residual Oil, !- Name + FuelOilNo2, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.8469, !- Year Escalation 1 + 0.8257, !- Year Escalation 2 + 0.8681, !- Year Escalation 3 + 0.8988, !- Year Escalation 4 + 0.9289, !- Year Escalation 5 + 0.9604, !- Year Escalation 6 + 0.9897, !- Year Escalation 7 + 1.0075, !- Year Escalation 8 + 1.0314, !- Year Escalation 9 + 1.0554, !- Year Escalation 10 + 1.0861, !- Year Escalation 11 + 1.1278, !- Year Escalation 12 + 1.1497, !- Year Escalation 13 + 1.1620, !- Year Escalation 14 + 1.1743, !- Year Escalation 15 + 1.1852, !- Year Escalation 16 + 1.1948, !- Year Escalation 17 + 1.2037, !- Year Escalation 18 + 1.2071, !- Year Escalation 19 + 1.2119, !- Year Escalation 20 + 1.2139, !- Year Escalation 21 + 1.2194, !- Year Escalation 22 + 1.2276, !- Year Escalation 23 + 1.2365, !- Year Escalation 24 + 1.2420, !- Year Escalation 25 + 1.2461, !- Year Escalation 26 + 1.2509, !- Year Escalation 27 + 1.2550, !- Year Escalation 28 + 1.2591, !- Year Escalation 29 + 1.2638; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Natural gas, !- Name + NaturalGas, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9823, !- Year Escalation 1 + 0.9557, !- Year Escalation 2 + 0.9279, !- Year Escalation 3 + 0.9257, !- Year Escalation 4 + 0.9346, !- Year Escalation 5 + 0.9412, !- Year Escalation 6 + 0.9512, !- Year Escalation 7 + 0.9645, !- Year Escalation 8 + 0.9856, !- Year Escalation 9 + 1.0067, !- Year Escalation 10 + 1.0222, !- Year Escalation 11 + 1.0410, !- Year Escalation 12 + 1.0610, !- Year Escalation 13 + 1.0787, !- Year Escalation 14 + 1.0942, !- Year Escalation 15 + 1.1098, !- Year Escalation 16 + 1.1220, !- Year Escalation 17 + 1.1308, !- Year Escalation 18 + 1.1386, !- Year Escalation 19 + 1.1486, !- Year Escalation 20 + 1.1619, !- Year Escalation 21 + 1.1763, !- Year Escalation 22 + 1.1918, !- Year Escalation 23 + 1.2118, !- Year Escalation 24 + 1.2284, !- Year Escalation 25 + 1.2439, !- Year Escalation 26 + 1.2605, !- Year Escalation 27 + 1.2772, !- Year Escalation 28 + 1.2938, !- Year Escalation 29 + 1.3115; !- Year Escalation 30 + +LifeCycleCost:UsePriceEscalation, + U.S. Avg Commercial-Coal, !- Name + Coal, !- Resource + 2011, !- Escalation Start Year + January, !- Escalation Start Month + 0.9970, !- Year Escalation 1 + 1.0089, !- Year Escalation 2 + 1.0089, !- Year Escalation 3 + 0.9941, !- Year Escalation 4 + 0.9941, !- Year Escalation 5 + 1.0000, !- Year Escalation 6 + 1.0030, !- Year Escalation 7 + 1.0059, !- Year Escalation 8 + 1.0089, !- Year Escalation 9 + 1.0119, !- Year Escalation 10 + 1.0148, !- Year Escalation 11 + 1.0178, !- Year Escalation 12 + 1.0208, !- Year Escalation 13 + 1.0267, !- Year Escalation 14 + 1.0297, !- Year Escalation 15 + 1.0356, !- Year Escalation 16 + 1.0415, !- Year Escalation 17 + 1.0534, !- Year Escalation 18 + 1.0564, !- Year Escalation 19 + 1.0593, !- Year Escalation 20 + 1.0653, !- Year Escalation 21 + 1.0712, !- Year Escalation 22 + 1.0742, !- Year Escalation 23 + 1.0801, !- Year Escalation 24 + 1.0831, !- Year Escalation 25 + 1.0831, !- Year Escalation 26 + 1.0861, !- Year Escalation 27 + 1.0890, !- Year Escalation 28 + 1.0920, !- Year Escalation 29 + 1.0950; !- Year Escalation 30 + +OutputControl:ReportingTolerances, + 0.2, !- Tolerance for Time Heating Setpoint Not Met {deltaC} + 0.2; !- Tolerance for Time Cooling Setpoint Not Met {deltaC} + +Output:JSON, + TimeSeriesAndTabular, !- Option Type + No, !- Output JSON + No, !- Output CBOR + No; !- Output MessagePack + +Output:Table:SummaryReports, + AllSummary; !- Report Name 1 + +Site:Location, + Washington Dc Dulles IntL Ar, !- Name + 38.98, !- Latitude {deg} + -77.47, !- Longitude {deg} + -5, !- Time Zone {hr} + 82; !- Elevation {m} + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns DB=>MWB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 36.5, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 17.1, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns DP=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 22.5, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Dewpoint, !- Humidity Condition Type + 15.6, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns Enth=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 30.8, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Enthalpy, !- Humidity Condition Type + , !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + 59300, !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Clg .4% Condns WB=>MDB, !- Name + 7, !- Month + 21, !- Day of Month + SummerDesignDay, !- Day Type + 31.2, !- Maximum Dry-Bulb Temperature {C} + 14.4, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 19, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 5, !- Wind Speed {m/s} + 340, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAETau, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + 0.339, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + 2.366, !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + , !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Htg 99.6% Condns DB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + -12.4, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + -12.4, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 2.6, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Htg Wind 99.6% Condns WS=>MCDB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + 6.8, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Wetbulb, !- Humidity Condition Type + 6.8, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 12.4, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + +SizingPeriod:DesignDay, + SALT-LAKE-CITY-IAP Ann Hum_n 99.6% Condns DP=>MCDB, !- Name + 1, !- Month + 21, !- Day of Month + WinterDesignDay, !- Day Type + -10.7, !- Maximum Dry-Bulb Temperature {C} + 0, !- Daily Dry-Bulb Temperature Range {deltaC} + DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type + , !- Dry-Bulb Temperature Range Modifier Day Schedule Name + Dewpoint, !- Humidity Condition Type + -16.2, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} + , !- Humidity Condition Day Schedule Name + , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} + , !- Enthalpy at Maximum Dry-Bulb {J/kg} + , !- Daily Wet-Bulb Temperature Range {deltaC} + 86790, !- Barometric Pressure {Pa} + 2.6, !- Wind Speed {m/s} + 140, !- Wind Direction {deg} + No, !- Rain Indicator + No, !- Snow Indicator + No, !- Daylight Saving Time Indicator + ASHRAEClearSky, !- Solar Model Indicator + , !- Beam Solar Day Schedule Name + , !- Diffuse Solar Day Schedule Name + , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} + , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} + 0, !- Sky Clearness + , !- Maximum Number Warmup Days + FullResetAtBeginEnvironment; !- Begin Environment Reset Mode + + + +OutputControl:Table:Style, + HTML; !- Column Separator + +Output:VariableDictionary, + IDF, !- Key Field + Unsorted; !- Sort Option + +Output:SQLite, + SimpleAndTabular; !- Option Type + +LifeCycleCost:NonrecurringCost, + Default Cost, !- Name + Construction, !- Category + 0, !- Cost + ServicePeriod; !- Start of Costs + +Output:Table:Monthly, + Building Energy Performance - Electricity, !- Name + 2, !- Digits After Decimal + InteriorLights:Electricity, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:Electricity, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:Electricity, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:Electricity, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:Electricity, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:Electricity, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:Electricity, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:Electricity, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:Electricity, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:Electricity, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:Electricity, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:Electricity, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:Electricity, !- Variable or Meter Name 13 + SumOrAverage, !- Aggregation Type for Variable or Meter 13 + Refrigeration:Electricity, !- Variable or Meter Name 14 + SumOrAverage; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - Natural Gas, !- Name + 2, !- Digits After Decimal + InteriorEquipment:NaturalGas, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorEquipment:NaturalGas, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + Heating:NaturalGas, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + Cooling:NaturalGas, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + WaterSystems:NaturalGas, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Cogeneration:NaturalGas, !- Variable or Meter Name 6 + SumOrAverage; !- Aggregation Type for Variable or Meter 6 + +Output:Table:Monthly, + Building Energy Performance - District Heating, !- Name + 2, !- Digits After Decimal + InteriorLights:DistrictHeating, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:DistrictHeating, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:DistrictHeating, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:DistrictHeating, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:DistrictHeating, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:DistrictHeating, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:DistrictHeating, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:DistrictHeating, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:DistrictHeating, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:DistrictHeating, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:DistrictHeating, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:DistrictHeating, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:DistrictHeating, !- Variable or Meter Name 13 + SumOrAverage; !- Aggregation Type for Variable or Meter 13 + +Output:Table:Monthly, + Building Energy Performance - District Cooling, !- Name + 2, !- Digits After Decimal + InteriorLights:DistrictCooling, !- Variable or Meter Name 1 + SumOrAverage, !- Aggregation Type for Variable or Meter 1 + ExteriorLights:DistrictCooling, !- Variable or Meter Name 2 + SumOrAverage, !- Aggregation Type for Variable or Meter 2 + InteriorEquipment:DistrictCooling, !- Variable or Meter Name 3 + SumOrAverage, !- Aggregation Type for Variable or Meter 3 + ExteriorEquipment:DistrictCooling, !- Variable or Meter Name 4 + SumOrAverage, !- Aggregation Type for Variable or Meter 4 + Fans:DistrictCooling, !- Variable or Meter Name 5 + SumOrAverage, !- Aggregation Type for Variable or Meter 5 + Pumps:DistrictCooling, !- Variable or Meter Name 6 + SumOrAverage, !- Aggregation Type for Variable or Meter 6 + Heating:DistrictCooling, !- Variable or Meter Name 7 + SumOrAverage, !- Aggregation Type for Variable or Meter 7 + Cooling:DistrictCooling, !- Variable or Meter Name 8 + SumOrAverage, !- Aggregation Type for Variable or Meter 8 + HeatRejection:DistrictCooling, !- Variable or Meter Name 9 + SumOrAverage, !- Aggregation Type for Variable or Meter 9 + Humidifier:DistrictCooling, !- Variable or Meter Name 10 + SumOrAverage, !- Aggregation Type for Variable or Meter 10 + HeatRecovery:DistrictCooling, !- Variable or Meter Name 11 + SumOrAverage, !- Aggregation Type for Variable or Meter 11 + WaterSystems:DistrictCooling, !- Variable or Meter Name 12 + SumOrAverage, !- Aggregation Type for Variable or Meter 12 + Cogeneration:DistrictCooling, !- Variable or Meter Name 13 + SumOrAverage; !- Aggregation Type for Variable or Meter 13 + +Output:Table:Monthly, + Building Energy Performance - Electricity Peak Demand, !- Name + 2, !- Digits After Decimal + Electricity:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:Electricity, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:Electricity, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:Electricity, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:Electricity, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:Electricity, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:Electricity, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:Electricity, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:Electricity, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:Electricity, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:Electricity, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:Electricity, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:Electricity, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:Electricity, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - Natural Gas Peak Demand, !- Name + 2, !- Digits After Decimal + NaturalGas:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorEquipment:NaturalGas, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorEquipment:NaturalGas, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + Heating:NaturalGas, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + Cooling:NaturalGas, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + WaterSystems:NaturalGas, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Cogeneration:NaturalGas, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 7 + +Output:Table:Monthly, + Building Energy Performance - District Heating Peak Demand, !- Name + 2, !- Digits After Decimal + DistrictHeating:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:DistrictHeating, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:DistrictHeating, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:DistrictHeating, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:DistrictHeating, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:DistrictHeating, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:DistrictHeating, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:DistrictHeating, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:DistrictHeating, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:DistrictHeating, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:DistrictHeating, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:DistrictHeating, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:DistrictHeating, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:DistrictHeating, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +Output:Table:Monthly, + Building Energy Performance - District Cooling Peak Demand, !- Name + 2, !- Digits After Decimal + DistrictCooling:Facility, !- Variable or Meter Name 1 + Maximum, !- Aggregation Type for Variable or Meter 1 + InteriorLights:DistrictCooling, !- Variable or Meter Name 2 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 2 + ExteriorLights:DistrictCooling, !- Variable or Meter Name 3 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 + InteriorEquipment:DistrictCooling, !- Variable or Meter Name 4 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 + ExteriorEquipment:DistrictCooling, !- Variable or Meter Name 5 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 + Fans:DistrictCooling, !- Variable or Meter Name 6 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 + Pumps:DistrictCooling, !- Variable or Meter Name 7 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 + Heating:DistrictCooling, !- Variable or Meter Name 8 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 + Cooling:DistrictCooling, !- Variable or Meter Name 9 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 + HeatRejection:DistrictCooling, !- Variable or Meter Name 10 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 + Humidifier:DistrictCooling, !- Variable or Meter Name 11 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 + HeatRecovery:DistrictCooling, !- Variable or Meter Name 12 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 + WaterSystems:DistrictCooling, !- Variable or Meter Name 13 + ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 + Cogeneration:DistrictCooling, !- Variable or Meter Name 14 + ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 14 + +!- =========== ALL OBJECTS IN CLASS: OUTPUT:METER =========== + +Output:Meter, + Electricity:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + NaturalGas:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + DistrictCooling:Facility,!- Key Name + Timestep; !- Reporting Frequency + +Output:Meter, + DistrictHeating:Facility,!- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + NaturalGas:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + Electricity:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + DistrictCooling:Facility, !- Key Name + Timestep; !- Reporting Frequency + +Output:Meter:MeterFileOnly, + DistrictHeating:Facility, !- Key Name + Timestep; !- Reporting Frequency +