Update README.md
Browse files
README.md
CHANGED
|
@@ -5,4 +5,54 @@ tags:
|
|
| 5 |
- care-taker
|
| 6 |
- reference-design
|
| 7 |
- evaluation-only
|
| 8 |
-
---
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 |
- care-taker
|
| 6 |
- reference-design
|
| 7 |
- evaluation-only
|
| 8 |
+
---
|
| 9 |
+
|
| 10 |
+
## Important Notice
|
| 11 |
+
This model is provided for evaluation and development purposes only. It is not validated for and must not be used in clinical, diagnostic, or production settings. See #use-and-limitations.
|
| 12 |
+
|
| 13 |
+
---
|
| 14 |
+
## Model Information
|
| 15 |
+
|
| 16 |
+
### Description
|
| 17 |
+
people-present is a single-stage object detection model that detects caretakers and other persons in a NICU warmer video feed. It uses the same MobileNetV2 + FPN + anchor-free head architecture as the companion patient-present model, retrained on a person-detection objective. In the NICU Warmer reference pipeline, its bounding boxes are cross-referenced with patient-present detections via IoU overlap to classify each detected person as either "caretaker" or "patient". This model is a development and evaluation tool produced as part of Intel's NICU Warmer reference design and has not undergone clinical validation.
|
| 18 |
+
|
| 19 |
+
### Intended Use
|
| 20 |
+
This model is intended for use by software developers and researchers evaluating AI-assisted NICU monitoring workflows on Intel hardware. It demonstrates person detection in warmer video as a building block for caretaker-presence sensing. people-present itself does not provide any medical functionality, nor is it intended to process or interpret medical data for a medical purpose. Developers are responsible for independently validating and adapting people-present for their specific use case. It must not be used in live clinical environments or for any diagnostic or patient-safety purpose.
|
| 21 |
+
|
| 22 |
+
---
|
| 23 |
+
## Technical Specifications
|
| 24 |
+
| Attribute | Detail |
|
| 25 |
+
|-------------------|-------------------------------------|
|
| 26 |
+
| Architecture | MobileNetV2 backbone + FPN neck + anchor-free detection head |
|
| 27 |
+
| Parameters | ~5–7M (FP32) |
|
| 28 |
+
| Input | 992×800 RGB image (W×H), float32, normalized [0,1], NCHW |
|
| 29 |
+
| Output | [N, 5] — bounding boxes (x1, y1, x2, y2, confidence), post-NMS, pixel coords at input resolution |
|
| 30 |
+
| Training hardware | Intel Ultra Core |
|
| 31 |
+
| Framework | PyTorch (mmdetection) → OpenVINO IR FP32 |
|
| 32 |
+
|
| 33 |
+
---
|
| 34 |
+
## Use and Limitations
|
| 35 |
+
|
| 36 |
+
### Permitted Uses
|
| 37 |
+
- Evaluation and benchmarking of [domain] AI workflows
|
| 38 |
+
- Research and development
|
| 39 |
+
- Academic study
|
| 40 |
+
- Adaptation and modification for non-clinical applications
|
| 41 |
+
|
| 42 |
+
### Prohibited Uses
|
| 43 |
+
- Clinical or diagnostic use
|
| 44 |
+
- Production deployment without independent validation and
|
| 45 |
+
applicable regulatory authorization
|
| 46 |
+
- Use with live patients or real patient data (unless the user
|
| 47 |
+
has obtained all necessary authorizations)
|
| 48 |
+
- Any use that would cause Intel to be treated as the
|
| 49 |
+
manufacturer, provider, or deployer of a medical device
|
| 50 |
+
or regulated AI system
|
| 51 |
+
|
| 52 |
+
---
|
| 53 |
+
## License
|
| 54 |
+
The use of [Model Name] is governed by the Intel Non-Clinical
|
| 55 |
+
Evaluation Use License (link). By accessing this model, you
|
| 56 |
+
agree to the license terms.
|