| ==Phrack Inc.== | |
| Issue XIV, File 4 of 9 | |
| =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= | |
| The Reality of the Myth | |
| REMOBS | |
| by Taran King | |
| =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= | |
| In the past, many misconceptions have been made of the legendary | |
| REMOBS system. The term has been used and abused. It used to be known as | |
| REMOB, rather than the proper REMOBS, which stood for Remote Observation. The | |
| REMOBS is a REMote service OBservation System manufactured by Teltone, a | |
| company which makes various telephone equipment peripherals. | |
| REMOBS has a number of features. The REMOBS permits evaluation of | |
| equipment or employee performance. It allows observation of subscriber lines, | |
| CO, toll, and E&M trunks, repair bureaus, and operator positions. It can be | |
| portable or set up as dedicated remote terminals. The observer console can | |
| sample entire networks. REMOBS is compatible with all types of switching and | |
| transmission media. | |
| The purpose of the REMOBS system is to measure performance and | |
| service provided to customers in an impartial and unbiased manner. By | |
| monitoring the subscriber connections throughout the network switch, this can | |
| be achieved. The customer experiences are recorded and statistics are derived | |
| to provide service level indices. | |
| REMOBS is compatible with all switching systems including Step by | |
| Step, Crossbar, and electronic equipment. In each situation, it can observe | |
| almost any transmission point such as subscriber lines, inter- and | |
| intra-office trunks, toll trunks, E&M trunks, repair bureaus, commercial | |
| offices, and operator positions. The console operators can observe by phone | |
| line, from one location, any switch location/CO with the remote unit | |
| installed. | |
| The M-241 system (which includes the console and remote terminal) | |
| observes up to 40 circuits, but can scan up to 100 lines with a remote | |
| terminal. The terminal may observe up to 5 locations simultaneously, with a | |
| capacity to observe 500 circuits at any one time. | |
| The REMOBS system can observe all remote terminals at any switching | |
| system location through the console controls, making it feasible to observe an | |
| entire network. Remote terminals are equipped with plug-in connectors so they | |
| can be moved routinely to observe desired locations. | |
| The M-241 Remote Terminal: The remote terminal is located at the point of | |
| ========================== observation. It may be ordered in portable or | |
| dedicated configuration. The remote terminal remains inactive until accessed | |
| by the controlling console. The remote unit is 6.5" high, 22.88" wide, and | |
| 11.7" deep, arranged for relay rack mounting. | |
| The M-242 Observer's Console: Console operators access the remote terminals | |
| ============================= through telephone lines. Access to the remotes | |
| is limited to console operators who know the access number, timing, and four | |
| digit security code. Additional security is available with the optional | |
| security dialback feature. The System automatically scans observed circuits. | |
| The first circuit to become busy is selected and held by the system until the | |
| necessary information is secured, the operator presses the reset button, or | |
| the calling party goes on-hook. Timing circuits automatically drop the call | |
| 100 seconds after the calling party goes off-hook or, if answer supervision is | |
| present, 15 seconds after the called party answers. The console itself looks | |
| very much like a cash register. Where the digits are normally, there are | |
| places for the trunk identity, called number, stop clock, and memory. The | |
| pushbutton controls consist of the following: power (key switch), hold | |
| buttons, select buttons, calling party, called party, display hold, clear, | |
| O.G. line, auto reset, reset (manual), read (stop clock operate), talk, voice | |
| exclusion, memory, plus a standard touch-tone keypad with the A, B, C, and D | |
| keys. There are 2 monitor jacks, a volume control and, for the primitive | |
| lines and switches, a rotary dial next to the touch-tone keypad. The | |
| operator's console stands 2.25" in the front and 8.25" in the back; it's | |
| 17,25" wide and 16.5" deep. | |
| The observation system network is set up in the following manner. | |
| The operator observer is in an observing center at the local Central Office | |
| with the M-242 REMOBS Central Console (which looks like a telephone to the | |
| Central Office). Through the standard telephone network, communications | |
| occurs between the console and the remote. From the CO, through the incoming | |
| circuitry, it goes through the connector to the M-241 REMOBS Remote Terminal | |
| (which looks like a telephone to the access line). From there the connection | |
| is made to the circuits to be observed including the subscribers lines, | |
| line-finders, toll trunks, repair lines, etc. | |
| The information provided is both visual and audible. The visual | |
| display, showed on the panel, includes the identity of the remote terminal, | |
| the identity of the observed circuit, the signalled digits (up to 52), the | |
| status of the calling and called parties (on/off-hook), and the timing of the | |
| call. The audible information (which is provided through headset or handset) | |
| includes the call progress tones for disposition (dial tone, type of | |
| signalling, 60 IPM, 120 IPM, ringing, answer, etc.) and voice transmission | |
| (calling and called parties). | |
| The REMOBS system is very much different from often-misconceived | |
| system known as 4Tel made by Teredyne. REMOBS is very much different from the | |
| dial-up - enter 1 code - be given instructions simplicity of the 4Tel but it | |
| still has the legendary capabilities of listening in remotely. | |
| If you wish to gain more information about the REMOBS system, Teltone | |
| Corporation can be written to at 10801 - 120th Avenue N.E., Kirkland, WA 98033 | |
| or phoned at (206) 827-9626. | |
| ______________________________________________________________________________ | |