| ==Phrack Magazine== | |
| Volume Five, Issue Forty-Five, File 21 of 28 | |
| **************************************************************************** | |
| The Universal Data Converter | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| Written by: Maldoror | |
| ~~~ChUrcH oF ThE nOnConFOrMisT~~~ | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| -=[ DELAMO LABS INC ]=- | |
| """"""""""""""""""""""""""""" | |
| What IS a UDC?! | |
| """"""""""""""" | |
| The Universal Data converter (UDC), by Applied Computing Devices, | |
| was put into widespread use in 1979. A UDC is used primarily in | |
| connection with a variety of switches, to log everything the switch does, | |
| and report it to the Central Office in a standard format, allowing the | |
| monitoring and reporting of a variety of different switches by one processor | |
| without the need of understanding each individual switch. This lets the | |
| Telco-Trouble shooters monitor exactly how much traffic is passing | |
| thru a given switch. Exact number of calls, busys & fraud attempts, are | |
| some examples. A UDC will give detailed reports of such activity, as | |
| well as hold it in a buffer file which you can view for your own excitement. | |
| The real purpose of this piece of hardware is to buffer data, convert it | |
| to a standard format, and send it on it's merry way to the Central Processor. | |
| Information may be buffered for up to an hour, before being able to be | |
| received by the Central Processor. | |
| Which Switches use a UDC? | |
| """"""""""""""""""""""""" | |
| Well, apparently, nearly all switches owned by a tel-co use a UDC | |
| for their daily reports. Here is a list of the switches of which I know | |
| may be connected to a converter: | |
| At&t Autoplex 100 | |
| ITT/North 1210 | |
| ITT/North NX-1E | |
| ITT/North "1200" Series (DSS-1) | |
| GTE GTD-1 (Automatic Electric no. 1 EAX) | |
| GTE GTD-2 (Automatic Electric no. 2 EAX) | |
| GTE GTD-3 (Automatic Electric no. 3 EAX) | |
| GTE GTD-5 | |
| Motorola EMX-250 | |
| NEC NEAX-61 | |
| NEC ND-20S | |
| Northern Telecom DMS-10 | |
| Northern Telecom DMS-100 | |
| Northern Telecom DMS-200 | |
| Northern Telecom DMS-250 | |
| Northern Telecom DMS-300 | |
| Northern Telecom SL-1 (Seen these around locally) | |
| Northern Telecom SP-1 PABX | |
| Stromberg Carlson DCO | |
| TRW Vidar ITS-4 | |
| TRW Vidar ITS-4/5 | |
| TRW Vidar ITS-5 | |
| Western Electric 5 ESS | |
| GTE PBX's (GTD-1000, GTD-4600) | |
| General Configurations: | |
| """"""""""""""""""""""" | |
| A UDC may be configured in several ways. A UDC consists of up to 6 ports. | |
| Port 0 is usually a dialin line, in which it is connected to a 300/1200 | |
| baud modem, so that GTE employees may call to check their switch | |
| information in the field. | |
| Port 0 may also be a dedicated line, which is linked to a computer somewhere | |
| important, but if this is the case, you can't have found it anyways, so don't | |
| worry about it. (Unless of course you another indial port possibly 1) | |
| Port 2 is usually the line which is hardwired to the data output of the | |
| switch. This port receives the messages of a switch, analyses the data, | |
| buffers it, and waits until it is told to send the data to the CP, which | |
| may be every time the buffer flips, which of course is configured by hardware. | |
| It is not required that port 2 be the hardwire, although it is just the | |
| most common configuration. | |
| Port 1 & 3-7 are also multi-use ports , which may be configured | |
| either for a dedicated line, or a standard phone line, just like port 1. | |
| The difference between this port and port 0 however, is that this port may | |
| also be used to test lines other than the hardware set report line #. | |
| (More later.) | |
| NOTE: ANY of these ports can be completely different depending on the | |
| setup of the UDC's cards, and which slot they are in... | |
| The UDC can be configured (though I have never seen it this way) so that any | |
| of the six ports can preform the functions instead of the first three. | |
| If you find a UDC, be sure to check all the ports, and not just three. | |
| The general idea of this box of tin is that it will monitor any | |
| switch, collect data into a buffer, and store it until it need be | |
| converted and polled by the SAC. When the data is sent out, it is sent | |
| in standard UDC format, regardless of the type of switch, therefore any | |
| switch may be monitored by the SAC without having to be converted on | |
| the spot. | |
| Yeah Great what the ?#!$ do I do? | |
| """"""""""""""""""""""""""""""""' | |
| Scan your local area for all numbers ending in 99xx or 00xx, often | |
| (with GTE anyways) the prefix may be something like 446-9988, or something | |
| outright obvious. Once you find one, you will know, because you will | |
| get one of two things. Depending on the configuration of the UDC, | |
| you will either begin getting a dump of data, which will go into detail | |
| about the switch information, or you will get a prompt: | |
| *B*> | |
| When you receive this prompt, you can make your life easy by typing | |
| HELP in all caps, for a menu of commands, which will seem important at | |
| first (don't fool yourself). | |
| Each letter between *'s represents a separate processor (yes even this tin | |
| box has more than one! These letters will be in the menu | |
| when you type HELP. To change processors, you will need to hold control | |
| while pressing the letter of the processor you wish to change to. | |
| Here is a list of commands for each processor: | |
| The Basic processor | |
| ~~~~~~~~~~~~~~~~~~~ | |
| *B*> DATE Display the system Date | |
| *B*> DATE mm/dd/yy Set the date to mm/dd/yy | |
| *B*> DIAGNOSTIC This puts you in debug mode for the UDC's program | |
| When typing this command the UDC will respond with | |
| "PASSWORD" and will not echo letters. If the password | |
| given is correct, you will get a prompt like this: | |
| *B*> DIAG | |
| PASSWORD 305 > I enter the good password< | |
| DEBUG 1,3 > 1,3 are the ports in use < | |
| ? | |
| At this point you can reboot the UDC by typing: | |
| ? G | |
| (ADDR)=1000 > I tell it to jmp to 1000 < | |
| Then all hell will break loose...trust me! | |
| O.k. well it will look like it anyway... | |
| *B*> HELP Duh um, a Menu | |
| *B*> RAMPAGE Test traffic data storage area | |
| *B*> SYSTEM Display system checksums | |
| *B*> TIME Display system time | |
| *B*> TIME hh:mm:ss Set system time (confuse them, set it back then forwd) | |
| The Patch Processor | |
| ~~~~~~~~~~~~~~~~~~~ | |
| *P*> ANSWER n Take channel 'n' off hook (neato) | |
| *P*> BAUD c,bbbb,nnn Set Channel 'c' Baud rate to 'bbbb', and | |
| number of nulls to 'nnn' | |
| *P*> HANGUP n Put channel 'n' on hook (log out too) | |
| *P*> HELP Help Menus | |
| *P*> PATCH n Patch calling port to port 'n' (Dial out!) | |
| It IS possible to patch to modem ports, but I don't | |
| recommend it...all GTE numbers have their own COS. | |
| (Easy to find you) | |
| The Plant Queue Processor | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| *Q*> ALARM Display the alarm (error message) string | |
| *Q*> ALARM xx..xxx Set Alarm String (change it back if u want) | |
| *Q*> CLEAR Clear buffer without printing contents (not preferred) | |
| *Q*> DUMP Print and clear contents (destructive, not preferred) | |
| *Q*> HELP Help Menu | |
| *Q*> LIMITS Display buffer alarm threshold | |
| *Q*> LIMITS nnnnn Set buffer alarm threshold to 'nnnn' | |
| *Q*> LIST Display buffer contents (Better than dump)(ok!) | |
| *Q*> LIST nnnn Display buffer contents from 'nnnn' to end | |
| The Report Processor | |
| ~~~~~~~~~~~~~~~~~~~~ | |
| *R*> BACKUP Transfer a copy of the ROM based table to the | |
| editor workspace | |
| *R*> DEFAULT Make the ROM based table effective (can crash) | |
| *R*> EDIT Engage in edit mode | |
| APPEND Add line to RMT (Hi there Gen-Tel!) | |
| DELETE Delete line from RMT | |
| END End edit session | |
| HELP List Editor Commands | |
| LIST List RMT | |
| MODIFY Modify a line in RMT | |
| *R*> DOWNLOAD Download RMT to PROM programmer (ha!) | |
| *R*> HELP More menus | |
| *R*> LIST List effective RMT | |
| *R*> LIST N List RMT without Heading | |
| *R*> LIST nnnn List line 'nnnn' of effective RMT | |
| *R*> LIST nnnnN List line 'nnnn' of effective RMT without heading | |
| *R*> LIST nnnn,mmmm List lines 'nnnn' to 'mmmm' of RMT | |
| *R*> LIST nnnn,mmmmN List lines 'nnnn' to 'mmmm' of RMT without heaading | |
| *R*> NEW Clear the editor workspace | |
| *R*> USER Make RAM based RMT active | |
| The Scanner Processor | |
| ~~~~~~~~~~~~~~~~~~~~~ | |
| *S*> CIRCUIT Display Status Report | |
| *S*> CIRCUIT nnn OFF Turn off circuit 'nnn' and print Status report | |
| *S*> CIRCUIT nnn OFF N Turn off circuit 'nnn' without report | |
| *S*> CIRCUIT nnn,mmm OFF Turn off circuts 'nnn' to 'mmm' | |
| *S*> CIRCUIT nnn,mmm OFF N Turn off 'nnn' to 'mmm' without report | |
| *S*> CIRCUIT nnn ON Turn 'nnn' ON and print report | |
| *S*> CIRCUIT nnn ON N Turn 'nnn' ON without report | |
| *S*> CIRCUIT nnn,mmm ON Turn circuts 'nnn' to 'mmm' on and print status report | |
| *S*> CIRCUIT nnn,mmm,ON N Turn on 'nnn' to 'mmm' but do not print report | |
| *S*> REPORT Display names of disable reports | |
| *S*> REPORT report.type OFF Disable 'report.type' for printing | |
| *S*> REPORT report.type ON Enable 'report.type' for printing | |
| *S*> RESTART Restart scanner interrogation | |
| *S*> ROUTE n Display all future alarm reports on channel 'n' | |
| *S*> STOP Stop scanner interrogation | |
| *S*> TEST Dial the alarm number set on the system optioning | |
| board (dip switches on the config board) for | |
| communication line testing. | |
| *S*> TEST 3,1 nnn nnn nnnn Dial the indicated number (on port 3) and test | |
| the communication lines. | |
| If you test with the port you called in on, | |
| you will have to hangup and call back for the | |
| results. (Port 0) | |
| The Traffic Processor | |
| ~~~~~~~~~~~~~~~~~~~~~ | |
| *T*> ACTIVE Display the contents of the active buffer | |
| *T*> BANK Display bank to be polled | |
| *T*> BANK n Set Bank to be polled (bank 'n') | |
| *T*> FLIP Flip the buffers (this MAY cause polling, depending | |
| on the hardware (switch) & port configuration) | |
| *T*> HELP Processor Menus | |
| *T*> METERS Display current meter limits | |
| *T*> METERS nnnn Set upper meter limits | |
| *T*> METERS mmmm,nnnn Set lower and upper meter limits | |
| *T*> METERS mmmm,nnnn V Set variable meter limits | |
| *T*> METERS mmmm,nnnn F Set fixed meter limits | |
| *T*> PASSIVE Display the contents of a Passive buffer | |
| *T*> TRAFFIC Interrupt or resume traffic after user interaction | |
| with channel 1 | |
| Standard Control Codes | |
| ~~~~~~~~~~~~~~~~~~~~~ | |
| ^A Start of Heading | |
| ^B Start of Text | |
| ^C End of Text | |
| ^D End of transmission | |
| ^E Enquiry (no not like CBI) | |
| ^F Acknowledgment | |
| ^G Bell :) | |
| ^H Backspace | |
| ^I Horizontal Tab | |
| ^J Line feed | |
| ^K Vertical Tab | |
| ^L Form Feed | |
| ^M Carriage return | |
| ^N Shift out | |
| ^O Shift in | |
| ^P Data line escape | |
| ^Q Device Control 1 | |
| ^R Device Control 2 | |
| ^S Device Control 3 | |
| ^T Device Control 4 | |
| ^U Negative Acknowledgment | |
| ^V Synchronous Idle | |
| ^W End of Transmission Block | |
| ^X Cancel | |
| ^Y End of Medium | |
| ^Z Substitute | |
| What is all this? | |
| ~~~~~~~~~~~~~~~~ | |
| The RMT data is the data transmitted to the UDC by the switch. This data | |
| is formatted in such a way that it tells the UDC what is happening and what | |
| has already happened since the last buffer flip. This data is then converted | |
| to a standard format to be transferred to the Central Processor. For examples | |
| of switch output, refer to the switch example list further in this article. | |
| Here is an example of the System Output data, after being translated into | |
| standard format by the UDC: | |
| The first two lines of the System Output data will contain the values | |
| of the 19 status registers as follows: | |
| 0 1 2 3 4 5 6 7 8 9 | |
| 000 00345 00003 00013 00000 00005 00000 00005 01903 00012 00000 | |
| 001 06800 01021 01101 01065 00000 00003 00007 02435 00000 00000 | |
| 10 11 12 13 14 15 16 17 18 19 | |
| The registers are as follows: | |
| 0 UDC control program number (usually 345, newer versions may be diff.) | |
| 1 UDC control program version (1,3,5,etc.) | |
| 2 Hour at buffer flip (active to passive) | |
| 3 Minute at buffer flip (active to passive) | |
| 4 Number of buffer flips since power on (65535 maximum) | |
| 5 Power interrupt flag (99 if fewer than two intervals have occurred | |
| since the power interrupt or hard restart; 0 otherwise) | |
| 6 Number of reports in the buffer | |
| 7 Total number of meters in this buffer (including headers) | |
| 8 Hour at buffer flip (passive to active) | |
| 9 Minute at buffer flip (passive to active) | |
| 10-13 Strapping Card signature | |
| 14 Total number of errors since last had reset or power up | |
| 15 Number of soft restarts since last power-up or hard restart | |
| 16 Number of buffer flips since last soft restart | |
| 17 Address of last error which caused a soft restart | |
| 18-19 unused | |
| When a traffic report is to be sent, the following header will be sent | |
| (in the System Output) to the UDC processor(s) to tell the traffic processor | |
| to begin buffering the report: | |
| 0 1 2 3 4 5 6 7 8 9 | |
| 190 65535 00008 00022 00000 00000 00000 00000 00000 00000 00000 | |
| 191 00004 00027 00078 00700 00800 31227 00074 00000 00002 00018 | |
| 192 00078 00000 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 10 11 12 13 14 15 16 17 18 19 | |
| The registers for the header are as follows: | |
| 0 65535 (This signals the beginning of the switch report) | |
| 1 Message type obtained from the 'type' field of the RMT | |
| 2 The number of registers used by the message, including the | |
| 10 registers of this header. | |
| 3-9 unused (00000) | |
| Ok ?! Now what?! | |
| ~~~~~~~~~~~~~~~~~ | |
| Well now that I have explained all the commands, the data formats, etc, | |
| of the UDC, you can now check the RMT or TRAFFIC buffers to see exactly | |
| what type of switch you are monitoring. Here are some examples of the | |
| Data format for the following switches: | |
| ************************************************************************ | |
| ------------------- AT&T AUTOPLEX 100 SWITCH ------------------------- | |
| ************************************************************************ | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| ------------------------------------------------------------------------------ | |
| 001 000 /M 00/ 001 075 255 65535 65535 | |
| 002 001 /BLOCK C/ 002 077 001 00020 00169 | |
| 003 002 /FINISH/ 001 073 255 65535 65535 | |
| 004 001 /CELL 001/ 001 077 002 00170 00229 | |
| 005 001 /CELL 002/ 001 077 003 00230 00289 | |
| 006 001 /CELL 003/ 001 077 004 00290 00349 | |
| 007 001 /CELL 005/ 001 077 005 00350 00409 | |
| 008 001 /CELL 006/ 001 077 006 00410 00469 | |
| 009 001 /CELL 007/ 001 077 007 00470 00529 | |
| 010 001 /CELL 008/ 001 077 008 00530 00589 | |
| 011 001 /CELL 009/ 001 077 009 00590 00649 | |
| 012 001 /CELL 010/ 001 077 010 00650 00709 | |
| 013 001 /CELL 011/ 001 077 011 00710 00769 | |
| 014 001 /CELL 012/ 001 077 012 00770 00829 | |
| 015 001 /CELL 013/ 001 077 013 00830 00889 | |
| 016 001 /BLOCK H/ 001 077 014 00890 00949 | |
| 017 001 /FINISH/ 001 073 255 65535 65535 | |
| Example of TRAFFIC report: | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| M 00 3/7/1993 THU 13:00:00 | |
| #068 | |
| A 30 | |
| BLOCK C 000034 13:00 3/7/1993 12:00 3/7/1993 | |
| (0) | |
| 000100 000313 000197 000049 000029 000103 000226 000125 000220 000066 | |
| (1) | |
| 000180 000291 000238 000123 000050 000154 000326 000146 000074 000089 | |
| (2) | |
| 000000 000007 000000 000000 000000 000000 000000 000000 000000 000000 | |
| (3) | |
| 000000 000000 000000 000000 000000 000000 000000 000036 000180 000000 | |
| (4) | |
| 000023 000023 000366 000000 000000 000000 000000 000000 000000 000000 | |
| (5) | |
| . | |
| . | |
| . | |
| (more data) | |
| . | |
| . | |
| (13) | |
| 000000 000000 000000 000000 000000 000000 000000 000000 000000 000000 | |
| FINISH | |
| 03/07/93 13:30:38 | |
| #371 | |
| . | |
| . | |
| . | |
| M 00 3/7/1993 THU 13:00:00 | |
| #068 | |
| 00 REPT:AMPSTRSF CELL 001 START 120 STOP 130 03/07 COMPLETE | |
| 000089 000014 000000 000000 000000 000000 000084 000014 000201 000001 | |
| 000052 000050 000048 000036 000002 000008 000003 000199 000000 002654 | |
| 000000 000031 000000 000360 000000 000000 000000 000036 003728 005170 | |
| 000000 004065 003170 000000 003992 000071 000000 000067 000146 000000 | |
| 000241 000000 000000 000000 000000 000000 000000 000000 000000 000000 | |
| #077 | |
| M 00 REPT:RC CENSUS | |
| OFFICE RC CHANNEL = REM | |
| TRCA OVER 0% FULL | |
| RBA OVER 5% FULL | |
| RCMDS MODE = 0 | |
| #082 | |
| M 00 REPT:RC SOURCE | |
| SCV=0 | |
| CFV=0 | |
| RCS=0 | |
| DLY=0 | |
| VSS=0 | |
| ACS=0 | |
| CSR=0 | |
| BIS=0 | |
| TRB=0 | |
| FBP=0 | |
| LOG=0 | |
| CR6=0 | |
| #083 | |
| . | |
| . | |
| . | |
| (more) | |
| . | |
| . | |
| ************************************************************************* | |
| --------------------- ITT/North 1210 Switch -------------------------- | |
| ************************************************************************* | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 003 FIXED LOWER: 00000 UPPER: 02039 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| ------------------------------------------------------------------------------- | |
| 001 000 /:/ 001 076 255 65535 65535 | |
| 002 001 /TYPE/ 002 073 255 65535 65535 | |
| 003 002 /2 / 003 077 002 00020 00098 | |
| 004 002 /4 / 003 077 004 00100 00319 | |
| 005 002 /5 / 003 077 005 00320 00469 | |
| 006 002 /16 / 003 077 016 00670 01769 | |
| 007 002 /18 / 003 077 018 01770 02040 | |
| 008 002 /20 / 003 077 020 00470 00669 | |
| 009 003 /END/ 000 073 255 65535 65535 | |
| Example of a TRAFFIC report: | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| DSS-1 VAR-00 VER-00 PAT=43 ACD | |
| 938 R TRAFF 4703 12/06/93 09:00:00 SBG-B | |
| DATA FROM 1210 SWITCH TO UDC | |
| DIAL TONE DELAY | |
| TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE | |
| 2 R 10 21(45) 08:00 60 12/16/93 | |
| THRESHOLD TIME 2.0 | |
| LSID DTD TIME(SEC) CALLS DELAY CALLS | |
| 1 .34 60 1 | |
| 2 .47 34 0 | |
| SYS TOTAL .43 94 1 | |
| END | |
| 936 TRAFF 4703 12/06/93 09:45:55 SBG-B | |
| SEPERATIONS | |
| TYPE CODE SCAN(SEC) BRP START/TIME LENGTH(MIN) ORDER/DATE | |
| 4 R NONE 10(43Z 12:00 60 12/06/79 | |
| CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE CNTR* VALUE | |
| 1 32 2 65 3 73 4 84 5 64 | |
| 6 42 7 84 8 51 9 63 10 69 | |
| END | |
| 9344 TRAFF 4703 12/06/93 09:46:00 CALL COUNT | |
| . | |
| . | |
| (more) | |
| . | |
| . | |
| note: This thing is a beast! If you find one of these call | |
| a museum quick!!! | |
| ************************************************************************* | |
| --------------- ITT/North NX-1E Switch ----------------------- | |
| ************************************************************************* | |
| RMT data example: | |
| """""""""""""""""" | |
| ACTION IN LINE 000 VARIABLE LOWER: 00000 UPPER: 00019 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| --------------------------------------------------------------------------- | |
| 001 000 /:/ 001 076 255 65535 65535 | |
| 002 001 /DATA TYPE/ 001 078 001 65535 65535 | |
| 003 001 /END OF/ 000 073 255 65535 65535 | |
| Example of a TRAFFIC report: | |
| """""""""""""""""""""""""""" | |
| 26 JUNE 86 10:00:00 THT 735 TM GROUPED DATA DUMP REPORT | |
| TIME OF LAST REPORT: 26 JUNE 78 09:00:00 | |
| DATA TYPE GROUPED DATA | |
| SOTU 572 681 | |
| SOTP 434 863 | |
| RSOU 894 | |
| RSOP 978 | |
| GTCA 1 1 2 3 4 5 6 | |
| SLA 0 0 0 0 1 1 1 | |
| TKTU 631 408 17 358 951 426 324 | |
| 436 384 277 462 46 853 956 | |
| TKTP 543 753 783 34 572 294 815 | |
| 426 85 357 392 739 212 142 | |
| TK2U 584 282 53 19 | |
| BSWU 27 7 | |
| QTCU 18 | |
| END OF GROUPED DATA DUMP | |
| *************************************************************************** | |
| ----------- THE GTE GTD-1 (Automatic Electric No.1 EAX) Switch------------- | |
| *************************************************************************** | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| --------------------------------------------------------------------------- | |
| 001 000 /HO UR/ 000 075 255 65535 65535 | |
| 002 000 /MS 19/ 001 077 001 00020 00039 | |
| 003 001 /MS 19/ 001 081 001 00101 65535 | |
| 004 001 /COUNTS/ 001 073 255 65535 65535 | |
| 005 001 /MS 21/ 002 077 002 00040 00079 | |
| 006 002 /MS 21/ 002 081 001 00101 65535 | |
| 007 002 /COUNTS/ 003 073 255 65535 65535 | |
| Example of TRAFFIC report: | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| I 00 HO UR 1:00:00 | |
| R 00 ME RR 9 | |
| R 00 MS 19 7 COUNTS GREATER THAN 0 | |
| R 00 MS 19 1,01 1152 1,02 1350 1,03 1194 | |
| R 00 MS 19 1,04 1378 1,05 1212 1,06 1231 | |
| R 00 MS 19 1,07 1099 | |
| R 00 MS 21 7 COUNTS GREATER THAN 0 | |
| R 00 MS 21 1,01 397 1,02 570 1,03 574 | |
| R 00 MS 21 1,04 542 1,05 682 1,06 668 | |
| R 00 MS 21 1,07 542 | |
| R 00 MS 22 7 COUNTS GREATER THAN 0 | |
| ************************************************************************** | |
| --------- THE GTE GTD-2 (Automatic Electric No.2 EAX) Switch ------------- | |
| ************************************************************************** | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 007 VARIABLE LOWER: 00000 UPPER: 00079 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| --------------------------------------------------------------------------- | |
| 001 000 /S@/ 001 084 255 65535 65535 | |
| 002 001 /MPTK/ 001 078 001 65535 65535 | |
| 003 001 /MPSW/ 001 078 002 65535 65535 | |
| 004 001 /MPLB/ 001 078 003 65535 65535 | |
| 005 001 /MPMA/ 001 078 004 65535 65535 | |
| 006 001 /MPLS/ 001 078 005 65535 65535 | |
| 007 001 /MPSP/ 001 078 006 65535 65535 | |
| Example of TRAFFIC report: | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| S@1900 TDA MPTK 08-14-86 1900 2000 | |
| TRK ICT ICT ICT OGT OGT OGT PRE | |
| GRP USAGE ATT HITS USAGE ATT OFL DIAL | |
| 128 0 0 0 31 18 0 0 | |
| 129 0 0 0 32 12 0 0 | |
| 130 0 0 0 0 0 0 0 | |
| 131 0 0 0 486 269 0 0 | |
| 132 0 0 0 55 13 0 0 | |
| 133 317 143 0 264 108 0 0 | |
| 134 0 0 0 1 2 0 0 | |
| S@1901 TDA PMSW 08-14-86 1900 2000 | |
| SVC USAGE ATT OFL | |
| 10 3 | |
| 10 3 164 0 | |
| 11 17 163 0 | |
| 14 302 2523 0 | |
| 15 200 2391 0 | |
| 16 377 2187 0 | |
| 18 84 1171 0 | |
| 19 113 1477 0 | |
| ************************************************************************** | |
| ------------------- The Motorola EMX-250 Switch -------------------------- | |
| ************************************************************************** | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 00389 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| ---------------------------------------------------------------------------- | |
| 001 000 /TRA21/ 001 078 001 65535 65535 | |
| 002 001 / / 002 073 255 65535 65535 | |
| 003 002 /^M/ 000 078 002 65535 65535 | |
| Example of TRAFFIC report: | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| TRA21 0307 1400 1500 | |
| 0369 0000 00 | |
| 00129 00045 00178 00127 00000 00000 00000 00000 | |
| 00000 00000 00000 00001 00000 00000 00000 00000 | |
| 101 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 | |
| TRA30 0307 1400 1500 | |
| 0000 0000 00 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 247 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 2134 1 | |
| TRA31 0307 1400 1500 | |
| 0000 0000 00 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 253 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 | |
| TRA32 0307 1400 1500 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 00000 00000 00000 00000 00000 00000 00000 00000 | |
| 254 000 BBBBBBBBBBBBBBBBBBBBBBBBBB 262 1234 1 | |
| ************************************************************************ | |
| ----------------- NEC ND-20S SWITCH ----------------------- | |
| ************************************************************************ | |
| Example of RMT data | |
| """"""""""""""""""" | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| -------------------------------------------------------------------------- | |
| 001 000 /// 000 075 255 65535 65535 | |
| 002 000 /ORG. CALL/ 001 078 001 65535 65535 | |
| 003 001 /DUMP END/ 000 073 255 65535 65535 | |
| 004 000 /SPECIAL DU/ 001 078 002 65536 65535 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| 06/21 20:01 CON-TEST NG | |
| PL:1 0 5 4 5 4 6 PT:1 0 3 1 6 4 2 | |
| 06/21 20:02 * TRAFFIC NORMAL DUMP * | |
| COM ORG. CALL ATTEMPTS (PEG COUNT) | |
| 026613 000079 000233 00000 00000 00000 00038 | |
| 000000 000114 | |
| COM ORG. CALL COMPLETED (PEG COUNT) | |
| 012172 000049 000113 000047 | |
| OOH TER. CALL COMPLETED (PEG COUNT) | |
| 034146 000142 000000 | |
| OOH CALLED PARTY BUSY ENCOUNTERED (PEG COUNT) | |
| 003356 | |
| 06/21 20:04 *NORMAL DUMP END* | |
| 000000 000000 | |
| 00H CALLED OFFICE (PEG COUNT) | |
| 000000 000000 000000 000000 000000 000000 000000 000000 | |
| OOH A-LINK USAGE PER NW BASIS (CCS) | |
| 0733.80 0594.40 0000.00 0000.00 | |
| OOH TRUNK USAGE (CCS) OGY | |
| 0002.40 0004.20 0009.00 0001.60 0009.60 0002.20 0016.00 | |
| 0000.00 0003.00 0000.00 0000.00 0046.80 0000.00 0003.00 | |
| 06/21 20:22 *SPECIAL DUMP END* | |
| 06/21 20:22 | |
| *************************************************************************** | |
| ------------------ Northern Telecom DMS-10 Switch ------------------------- | |
| *************************************************************************** | |
| Example of RMT data: | |
| ~~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 011 VARIABLE LOWER: 00000 UPPER: 00560 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| -------------------------------------------------------------------------- | |
| 001 000 /OPM001/ 000 072 001 65535 65535 | |
| 002 000 /OPM002/ 000 078 002 65535 65535 | |
| 003 000 /OPM003/ 000 078 003 65535 65535 | |
| 004 000 /OPM004/ 000 078 004 65535 65535 | |
| 005 000 /OPM005/ 000 078 005 65535 65535 | |
| 006 000 /OPM006/ 000 078 006 65535 65535 | |
| 007 000 /OPM007/ 000 078 007 65535 65535 | |
| 008 000 /OPM008/ 000 078 008 65535 65535 | |
| 009 000 /OPM009/ 000 078 009 65535 65535 | |
| 010 000 /OPM010/ 000 078 010 65535 65535 | |
| 011 000 /OPM011/ 000 078 011 65535 65535 | |
| 012 000 /OPM012/ 000 078 012 65535 65535 | |
| 013 000 /OPM013/ 000 078 013 65535 65535 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| OPM001 TRAF HLST MON 08/19/86 15:00:00 HRHR | |
| PEG BLK USE | |
| ORTM 00635 00000 00978 | |
| OROG 00477 00000 00685 | |
| ORNC 00089 | |
| RVRT 00012 | |
| INTM 00429 00000 00707 | |
| INOG 00000 00000 00000 | |
| INNC 00003 | |
| OPM002 OSVC HLST MON 11/02/85 15:00:00 HRHR | |
| PEG | |
| PSIG 00027 | |
| PDTO 00015 | |
| PABN 00092 | |
| FSTR 00168 | |
| DGTC 00599 | |
| DPC 00874 | |
| TOTC 01473 | |
| % | |
| DGTS 000.0 | |
| DPS 000.0 | |
| TOTS 000.0 | |
| ************************************************************************ | |
| ----------------- Northern Telecom DMS-100 Switch ---------------------- | |
| ************************************************************************ | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 004 VARIABLE LOWER: 00000 UPPER: 01015 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| --------------------------------------------------------------------------- | |
| 001 000 /QWMPR2/ 001 075 255 65535 65535 | |
| 002 001 /SLOWS/ 002 077 001 00020 00999 | |
| 003 002 /TRMT2/ 003 068 066 65535 65535 | |
| 004 002 /ANN^J/ 002 068 119 65535 65535 | |
| 005 002 /SITE^J/ 003 073 255 65535 65535 | |
| 006 003 /TRK^J/ 004 077 002 01000 04499 | |
| 007 004 /KEY/ 005 081 019 00027 65535 | |
| 008 005 /QFZ^J/ 000 077 003 04500 04920 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| CMFLINT OMPR213 AUG13 15:01:09 3684 INFO CM REPORT | |
| CLASS: NMCTRAFF | |
| START: 1986/08/13 14:00:00 WED; STOP: 1986/08/13 15:00:00 WED; | |
| SLOWSAMPLES: 36; FASTSAMPLES: 360; | |
| CPU | |
| MTCHINT TRAPINT CPUFLT SYSWINIT SYSCINIT SYNCLOSS | |
| MSYLOSSU SSYLOSSU | |
| 0 0 0 0 0 0 0 | |
| 0 0 | |
| ICO | |
| IOCERR IOCLKERR IOCFLT IOCLKSBU IOLKMBU IOCSBU | |
| IOCMBU | |
| 0 0 0 0 0 0 0 | |
| 0 | |
| CMC | |
| KEY (CMC_INDEX) | |
| . | |
| . | |
| . | |
| *********************************************************************** | |
| ----------------- Northern Telecom DMS-250 ---------------------------- | |
| *********************************************************************** | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPER: 02387 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| -------------------------------------------------------------------------- | |
| 001 000 /QMPR2/ 001 072 255 65535 65535 | |
| 002 001 /INFO/ 002 073 255 65535 65535 | |
| 003 002 /SLOWS/ 000 078 001 65535 65535 | |
| Example of TRAFFIC data | |
| ~~~~~~~~~~~~~~~~~~~~~~ | |
| QMPR18 AUG28 17:00:43 4000 INFO QM REPORT | |
| CLASS:SCHOURDC | |
| START:1984/08/28 16:00:00 TUE; STOP: 1984/08/28 17:00:00 TUE; | |
| SLOWSAMPLES: 36; FASTSAMPLES | |
| TRMT1 | |
| VACT UNCA HNPI UNDN BLDN UNIN | |
| TESS | |
| 0 60 0 0 0 0 0 | |
| 0 0 0 | |
| TRMT2 | |
| DNTR CNOT DCFC PRSC GNCT ATBS | |
| MHLD | |
| 0 0 0 0 0 0 0 | |
| 0 0 | |
| QMPR220 AUG28 17:30:16 6100 INFO REPORT | |
| CLASS: ADHOURC | |
| START:1984/08/28 17:00:00 TUE; STOP 1984/08/28 18:00:00 TUE; | |
| SLOWSAMPLES: 36; FASTSAMPLES: 360; | |
| TRK | |
| KEY (COMMON_LANGUAGE_NAME) | |
| INFO (QM2TRKINFO) | |
| INCATOT PRERTEAB INFAIL NATMPT MOVFLATB GLARE | |
| QUTFAIL DEFLCDA DREU PREU TRU SBU | |
| ANSWER INVAUTH CONNECT TANDEM AQF ANF | |
| ********************************************************************* | |
| ---------------- Northern Telecom SL-1 Switch ---------------------- | |
| ********************************************************************* | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 005 (RAM) VARIABLE LOWER: 00000 UPPER: 00010 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| ------------------------------------------------------------------------- | |
| 001 000 /TFS000/ 001 073 255 65535 65535 | |
| 002 001 /19/ 002 073 255 65535 65535 | |
| 003 002 / / 000 084 255 65535 65535 | |
| 004 001 /TF/ 000 073 255 65535 65535 | |
| 005 002 /TF/ 000 073 255 65535 65535 | |
| 006 000 /TFS001/ 000 078 001 65535 65535 | |
| 007 000 /TFS002/ 000 078 002 65535 65535 | |
| 008 000 /TFS411/ 000 078 141 65535 65535 | |
| 009 000 /TFS412/ 000 078 142 65535 65535 | |
| 010 000 /TFS999/ 000 073 255 65535 65535 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| 001 TFS000 | |
| 13 10 1978 | |
| 10 30 00 | |
| 001 TFS102 | |
| 00 0000157 00100 | |
| 001 TFS102 | |
| 01 0000194 00100 | |
| 001 TFS102 | |
| 02 0000194 00100 | |
| . | |
| . | |
| . | |
| 001 TFS001 | |
| 00 TERM 00000 0000012 00023 00000 0000157 00161 | |
| 01 TERM 00000 0000028 00018 00000 0000256 00157 | |
| 02 TERM 00000 0000015 00019 00000 0000194 00134 | |
| 06 CONF 00000 0000000 00000 00000 0000001 00003 | |
| 07 TDS 00000 0000000 00000 00000 0000000 00000 | |
| . | |
| . | |
| . | |
| ************************************************************************ | |
| ---------------- Northern Telecom SP-1 PABX Switch --------------------- | |
| ************************************************************************ | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 013 VARIABLE LOWER: 00000 UPPER: 00042 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| -------------------------------------------------------------------------- | |
| 001 001 /JAN/ 002 073 255 65535 65535 | |
| 002 001 /FEB/ 002 073 255 65535 65536 | |
| 003 001 /MAR/ 002 073 255 65535 65535 | |
| 004 001 /APR/ 002 073 255 65535 65535 | |
| 005 001 /MAY/ 002 073 255 65535 65535 | |
| 006 001 /JUN/ 002 073 255 65535 65535 | |
| 007 001 /JUL/ 002 073 255 65535 65535 | |
| 008 001 /AUG/ 002 073 255 65535 65535 | |
| 009 001 /SEP/ 002 073 255 65535 65535 | |
| 010 001 /OCT/ 002 073 255 65535 65535 | |
| 011 001 /NOV/ 002 073 255 65535 65535 | |
| 012 001 /DEC/ 002 073 255 65535 65535 | |
| 013 002 /19/ 000 075 054 65535 65535 | |
| . | |
| . | |
| . | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| 0067 OPR MEA 00315 013077 18 - 200SUS | |
| LIN# 0 78 | |
| 2 2 8 0 0 32 0 36 0 2 82 | |
| LIN# 1 8 | |
| 0 0 8 0 0 32 0 0 32 2 0 | |
| WED 11 SEPT 1980 112777 | |
| 572 415 23 3 46 160 1992 0 | |
| 0 516 0 0 22 1 2180 0 | |
| 0055 OPR MEA 045331 112044 | |
| 2420 1713 101 10 327 628 4512 8512 0 | |
| WED 11 SEPT 1980 1:06:27 1606CLS3 | |
| . | |
| . | |
| . | |
| *********************************************************************** | |
| --------------- Stromberg Carlson DCO Switch (!!) --------------------- | |
| *********************************************************************** | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| -------------------------------------------------------------------------- | |
| 001 000 /COMPLETION/ 000 084 255 65535 65535 | |
| 002 000 /ROW/ 001 077 001 00100 02039 | |
| 003 001 /END OF TMR/ 000 073 255 65535 65535 | |
| 004 001 /***/ 002 073 255 65535 65535 | |
| 005 002 /^M/ 001 066 001 65535 65535 | |
| Example of a TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~ | |
| SITE:ACD,INC. GROUP: 1 BUFFER:ACTIVE | |
| COLLECTION TIME: 08:00:00 05/01/79 | |
| COMPLETION TIME: 08:01:05 05/01/79 | |
| ROW ODD3S ODTNP | |
| 0 1 2 | |
| 1 | |
| OLOSZ OLMAT ORVEC | |
| 2 3 2 1 | |
| OLOTB OLOTL OLOTP OLMDS OLMBY | |
| 3 7 2 1 8 3 | |
| 4 | |
| 5 | |
| ... | |
| . | |
| . | |
| . | |
| . | |
| *********************************************************************** | |
| -------------- TRW Vidar ITS 4/5 and ITS 5 Switches ------------------- | |
| *********************************************************************** | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 006 VARIABLE LOWER: 00000 UPPER: 00837 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| --------------------------------------------------------------------------- | |
| 001 000 /ITD REPORT/ 000 073 255 65535 65535 | |
| 002 000 / TO / 000 072 001 65535 65535 | |
| 003 000 /SYSTEM/ 000 078 002 65535 65535 | |
| 004 000 /GRADE/ 000 078 004 65535 65535 | |
| 005 000 /SEPAR/ 000 073 004 65535 65535 | |
| 006 000 /END/ 000 004 255 65535 65535 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| TIMED ITS REPORT ADAM FROM 08-18-86 13:01:31 TO 08-18-86 14:00:28 | |
| CLEARING COUNTERS | |
| GROUP TOTALS | |
| NAME TYPE ATT COM XCS AVH OFL | |
| LSSO ORIG 131 93 1671 13 0 | |
| LSSO TERM 129 98 1729 13 0 | |
| LSS1 ORIG 159 111 3093 19 0 | |
| LSS1 TERM 114 97 2793 25 0 | |
| LSS2 ORIG | |
| . | |
| . | |
| . | |
| . | |
| ********************************************************************* | |
| ------------- Western Electric ESS 5 Switch ------------------------- | |
| ********************************************************************* | |
| Example of RMT data | |
| ~~~~~~~~~~~~~~~~~~ | |
| ACTION IN LINE 003 VARIABLE LOWER: 00000 UPPPER: 00100 | |
| ENTRY REQUIRED STRING NEW ACTION TYPE STARTING ENDING | |
| PHASE PHASE REGISTER REGISTER | |
| ---------------------------------------------------------------------------- | |
| 001 000 /S570/ 001 075 255 65535 65535 | |
| 002 001 /TION 1:/ 002 078 001 65535 65535 | |
| 003 002 /TION 3:/ 003 078 002 65535 65535 | |
| Example of TRAFFIC report | |
| ~~~~~~~~~~~~~~~~~~~~~~~~ | |
| S570-108396613 86-05-13 12:01:22 12430 | |
| OP TRFC30 VLD | |
| TIME: 12:0:27 | |
| SECTION 1: VALIDITY | |
| PROC DATLOS SCN10 SCN100 | |
| 0 VALID 0 18 | |
| 7 VALID 180 18 | |
| 10 VALID 180 19 | |
| 9 VALID 180 18 | |
| 2 VALID 180 18 | |
| 6 VALID 180 18 | |
| 4 VALID 180 18 | |
| 3 VALID 180 18 | |
| 8 VALID 180 18 | |
| 5 VALID 180 18 | |
| 1 VALID 180 18 | |
| 11 VALID 180 18 | |
| S570-108396613 86-05-13 12:01:24 12431 | |
| OP TRFC30 OFC | |
| TIME 12:0:27 | |
| SECTION 3: OFFICE TOTALS | |
| DPORQ = 46 TTPRQ = 693 DPINRQ = 1226 | |