.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+# Table of Contents
+
+###### Page
+
+| | | |
+|------|-------------------------------------------------------------|----|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| 3.1 | Term defined elsewhere ..... | 2 |
+| 3.2 | Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Introduction to best practices for green data centres ..... | 3 |
+| 5.1 | Role of best practices..... | 3 |
+| 5.2 | Value of practices ..... | 4 |
+| 6 | Planning, utilization and management of data centres ..... | 4 |
+| 6.1 | Involvement of organizational groups..... | 4 |
+| 6.2 | General policies ..... | 4 |
+| 6.3 | Resilience level and provisioning..... | 4 |
+| 7 | ICT equipment and services ..... | 5 |
+| 7.1 | Selection of new ICT equipment..... | 5 |
+| 7.2 | Selection of new telecom equipment..... | 8 |
+| 7.3 | Deployment of new ICT services ..... | 8 |
+| 7.4 | Management of existing ICT equipment and services ..... | 9 |
+| 7.5 | Data management ..... | 10 |
+| 8 | Cooling ..... | 11 |
+| 8.1 | Airflow design and management..... | 11 |
+| 8.2 | Cooling management..... | 14 |
+| 8.3 | Temperature and humidity settings ..... | 15 |
+| 8.4 | Computer room air conditioners..... | 19 |
+| 8.5 | Re-use of data centre waste heat ..... | 22 |
+| 9 | Data centre power equipment ..... | 22 |
+| 9.1 | Selection and deployment of power equipment ..... | 22 |
+| 9.2 | Management of power equipment ..... | 24 |
+| 10 | Other data centre equipment..... | 25 |
+| 10.1 | General practices ..... | 26 |
+| 11 | Data centre building..... | 26 |
+| 11.1 | Building physical layout..... | 26 |
+| 11.2 | Building geographic location ..... | 27 |
+| 12 | Monitoring ..... | 28 |
+| 12.1 | Energy use and environmental measurement ..... | 28 |
+| 12.2 | Energy use and environmental collection and logging..... | 29 |
+| 12.3 | Energy use and environmental reporting..... | 29 |
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------------------------------------|------|
+| 12.4 ICT reporting ..... | 30 |
+| 13 Design of network..... | 31 |
+| 14 Cloud data centre ..... | 31 |
+| 14.1 High flexibility ..... | 31 |
+| 14.2 High-density data centre..... | 33 |
+| 14.3 Management optimization ..... | 34 |
+| 15 Optimization of energy management of whole data centre ..... | 35 |
+| 15.1 Optimization of energy management by an integrated control of ICT devices and facility ..... | 35 |
+| Annex A – Possible methodology for cooling data centres by using renewable energy in cold regions..... | 36 |
+| A.1 Data centres in cold regions ..... | 36 |
+| A.2 General matters relating to data centre cooling..... | 36 |
+| A.3 Outdoor air cooling..... | 36 |
+| A.4 Snow and ice cooling..... | 39 |
+| A.5 Method of cooling data centres in cold regions..... | 40 |
+| Annex B – Possible methodology for cooling data centres with high-density ICT devices.... | 42 |
+| B.1 Outline of air conditioning methods..... | 42 |
+| B.2 Selection of cooling systems suited to data centre specifications ..... | 49 |
+| Annex C – Practical solutions for correcting airflow direction for equipment..... | 51 |
+| C.1 Requirements for correcting airflow direction for equipment..... | 51 |
+| Annex D – Minimum data set for controlling data centre equipment for energy saving management in data centres..... | 52 |
+| Annex E – Verification experiments related to increase of efficiency of air-conditioning and control technologies at a data centre ..... | 53 |
+| E.1 Overview ..... | 53 |
+| E.2 Data centre energy model..... | 53 |
+| E.3 Control method to minimize energy consumption ..... | 56 |
+| E.4 Control system configuration ..... | 58 |
+| Bibliography..... | 60 |
+
+# Recommendation ITU-T L.1300
+
+## Best practices for green data centres
+
+# 1 Scope
+
+This Recommendation specifies best practices aimed at developing green data centres. A green data centre can be defined as a repository for the storage, management, and dissemination of data in which the mechanical, lighting, electrical and computer systems are designed for maximum energy efficiency and minimum environmental impact. The construction and operation of a green data centre includes advanced technologies and strategies. The Recommendation provides a set of rules to be referred to when undertaking improvement of existing data centres, or when planning, designing or constructing new ones.
+
+The proposed best practices cover:
+
+- data centre utilization, management and planning;
+- ICT equipment and services;
+- cooling;
+- data centre power equipment;
+- data centre building;
+- monitoring.
+
+The environmental impact of a data centre should be assessed in line with [ITU-T L.1400], [ITU-T L.1410] and [ITU-T L.1420].
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T L.1400] Recommendation ITU-T L.1400 (2011), *Overview and general principles of methodologies for assessing the environmental impact of information and communication technologies*.
+- [ITU-T L.1410] Recommendation ITU-T L.1410 (2012), *Methodology for the assessment of the environmental impact of information and communication technology goods, networks and services*.
+- [ITU-T L.1420] Recommendation ITU-T L.1420 (2012), *Methodology for energy consumption and greenhouse gas emissions impact assessment of information and communication technologies in organizations*.
+- [ETSI EN 300 019-1-3] ETSI EN 300 019-1-3 V2.3.2 (2009), *Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-3: Classification of environmental conditions; Stationary use at weather protected locations*.
+
+| | |
+|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ETSI TR 102 489] | ETSI TR 102 489 V1.2.1 (2010), Environmental Engineering (EE); European telecommunications standard for equipment practice; Thermal Management Guidance for equipment and its deployment. |
+| [ISO/IEC 62040-3] | ISO/IEC 62040-3 Ed2.0 (2011), Uninterruptible Power Systems (UPS) – Part 3: Method of specifying the performance and test requirements. |
+
+# 3 Definitions
+
+## 3.1 Term defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 power density:** The energy consumption of ICT equipment per rack cabinet of floor area of a server room.
+
+**3.2.2 space efficiency:** The ratio of floor area employed for ICT equipment in relation to the total floor area of the building.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|----------------------------------------------------------------------|
+| AHU | Air Handling Unit |
+| ATS | Automatic Transfer Switch |
+| BC | Business Continuity |
+| BIOS | Basic Input-Output System |
+| BREEAM | Building Research Establishment Environmental Assessment Methodology |
+| CFD | Computational Fluid Dynamics |
+| COP | Coefficient Of Performance |
+| CRAC | Computer Room Air Conditioner |
+| DC | Data Centre |
+| DCMI | Data Centre Manageability Interface |
+| DX | Direct expansion |
+| DR | Disaster Recovery |
+| HVAC | Heating Ventilation and Air Conditioning |
+| ICT | Information and Communication Technology |
+| IGBT | Insulated-Gate Bipolar Transistor |
+| IPMI | Intelligent Platform Management Interface |
+| LEED | Leadership in Energy and Environmental Design |
+| M&E | Maintenance and Engineering |
+| OA | Outdoor Air |
+| PDU | Power Distribution Unit |
+
+| | |
+|---------|--------------------------------------------------------------------|
+| PSU | Power Supply Unit |
+| PUE | Power Usage Effectiveness |
+| RA | Return Air |
+| REACH | Registration, Authorization and restriction of Chemical substances |
+| RH | Relative Humidity |
+| RoHS | Restrictions of Hazardous Substances |
+| RT | Refrigerant Ton |
+| SA | Supply Air |
+| SMASH | Systems Management Architecture for Server Hardware |
+| SNMP | Simple Network Management Protocol |
+| Tri-Gen | Tri-Generation |
+| UPS | Uninterruptible Power Supply |
+| VFI | Voltage and Frequency Independent |
+| WEEE | Waste Electrical and Electronic Equipment |
+
+# 5 Introduction to best practices for green data centres
+
+In order to improve the energy efficiency of data centres, it is necessary to consider all stages from design through to construction. Even after the building of data centres is complete, they must continue to be managed and maintained to ensure efficient energy consumption.
+
+This Recommendation describes best practices for energy-efficient construction, operation and management of green data centres that contain a number of essential components, including ICT equipment and services, cooling, power equipment, data centre building, etc.
+
+The best practices discussed herein have been numbered for easy reference.
+
+Best practices have been identified and divided into different clauses to cover the following different components of a data centre:
+
+- planning, utilization and management;
+- ICT equipment and services;
+- cooling;
+- data centre power equipment;
+- other data centre equipment;
+- data centre building;
+- monitoring;
+- design of network;
+- cloud data centre;
+- optimization of energy management of the whole data centre.
+
+## 5.1 Role of best practices
+
+This Recommendation is provided as a comprehensive guide to assist data centre operators in identifying and implementing measures to improve energy efficiency of their data centres.
+
+The full list of best practices that are specified in this Recommendation can be of practical help for those who are pursuing green data centres.
+
+## 5.2 Value of practices
+
+Each practice has not been assigned a qualitative value to indicate the level of benefit to be expected from an action and the relative priorities that should be applied to it.
+
+When there is a choice of practices, a preference should be given to the one having the least impact on the environment.
+
+# 6 Planning, utilization and management of data centres
+
+It is important to develop a holistic strategy and management approach to the data centre to support economic efficiency and environmental benefits.
+
+## 6.1 Involvement of organizational groups
+
+Effective communication between different departments working in the data centres is crucial to ensure efficiency and thereby avoid capacity and reliability issues.
+
+To ensure effective communication, the following steps are proposed:
+
+| No. | Name | Description |
+|-------|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 6.1.1 | Group involvement | Establish an "Approval Board" composed of representatives from different departments (e.g., software, ICT, power cooling and other facilities). Submit all important decisions for board approval to ensure that all possible impact has been fully understood and that an effective solution has been identified. For example, one of the decisions could be the definition of standard ICT hardware lists through considering the maintenance and engineering (M&E) implications of different types of hardware. |
+
+## 6.2 General policies
+
+These policies apply to all aspects of the data centre and its operation.
+
+| No. | Name | Description |
+|-------|--------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 6.2.1 | Consider the embedded energy in devices | Carry out an audit of existing equipment to ensure that optimal use is made of existing capability before making any new investment. |
+| 6.2.2 | Mechanical and electrical equipment environmental operating ranges | Recommend the selection and deployment of mechanical and electrical equipment which does not itself require refrigeration. Note that this refers to mechanical compressors and heat pumps, any device which uses energy to raise the temperature of the rejected heat. |
+| 6.2.3 | Lifecycle Analysis | Introduce a plan for lifecycle assessment (LCA) in accordance with [ITU-T L.1410]. |
+
+## 6.3 Resilience level and provisioning
+
+One of the most significant sources of inefficiency in a data centre is the over-provision of space, power or cooling, and the use of existing facilities operating at partial capacity. Monolithic design, as opposed to modular design, of facilities is also frequently an unnecessary capital expenditure.
+
+| No. | Name | Description |
+|-------|---------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 6.3.1 | Build resilience to business requirements | Build or, in the case of a co-location customer, purchase only the level of resilience actually justified by business requirements and an impact analysis. Full backup (1+1) of infrastructure is frequently unnecessary and inappropriate. Resilience for a small portion of critical services can be obtained by using disaster recovery (DR)/business continuity (BC) sites. |
+| 6.3.2 | Consider multiple levels of resilience | Build a single data centre to provide multiple levels of power and cooling resilience to different floor areas. Many co-location providers already deliver this, for example, as optional "grey" power feeds without uninterruptible power supply (UPS) or generator back up. |
+| 6.3.3 | Design effective resilience | Utilize appropriate levels of resilience at the data centre ICT equipment, software and network levels to achieve the required service resilience. High resilience at the physical level is rarely an effective overall solution. |
+| 6.3.4 | Lean provision of power and cooling for a maximum of 18 months of data floor capacity | Avoid unnecessary fixed losses as a result of the provision of excess power and cooling capacity in the data centre. Plan a data centre for modular (scalable) expansion and then build upon this capacity in a rolling programme of deployment. This design is more efficient, allows the technology "generation" of ICT equipment, and supports the match of M&E infrastructure, thereby improving both efficiency and the ability to respond to business requirements. |
+| 6.3.5 | Design to maximize the partial load efficiency once provisioned | All areas of the data centre should be designed to maximize the efficiency of the facility under partial fill and variable ICT electrical load. This is in addition to one-off modular provisioning and considers the response of the infrastructure equipment to dynamic loads, e.g., variable frequency (or speed) drives for pumps and fan units. |
+
+# 7 ICT equipment and services
+
+ICT equipment creates the demand for power and cooling in the data centre. Any reduction in power and cooling used by, or provisioned for ICT equipment will have magnified effects for the utility energy supply.
+
+The purpose of environmental specifications of equipment, as outlined in the next clause, is to ensure that new equipment is capable of operating under the wider ranges of temperature and humidity, thus allowing the operator a greater flexibility in operating temperature and humidity.
+
+## 7.1 Selection of new ICT equipment
+
+Once ICT equipment is purchased and installed in the data centre, it is usually in use for several years, consuming power and creating heat. The appropriate selection of hardware and deployment methods can provide significant long-term savings.
+
+| No. | Name | Description |
+|-------|------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.1.1 | Multiple tender for ICT hardware – power | Include energy efficient performance of the ICT device as a high priority decision factor in the tender process e.g., through application or deployment of specific user metrics more closely aligned to the target environment, which may include service level or reliability components. The energy consumption of the device, at the expected utilization or applied workload, should be considered in addition to peak performance per watt figures. |
+
+| No. | Name | Description |
+|-------|-------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.1.2 | Multiple tender for ICT hardware – operating temperature and humidity range at equipment intake Low priority practices | Include the operating temperature and humidity ranges at the intake of new equipment as high priority decision factors in the tender process. The minimum range, at the air intake to servers, is 18°C-32°C and 5.5°C dew point up to 15°C dew point and 60% RH. This is defined in [b-ASHRAE TC 9.9]. |
+| 7.1.3 | Multiple tender for ICT hardware – extended operating temperature and humidity range High priority practices | Introduce a stronger requirement for new ICT equipment stipulating the need for them to withstand the air inlet temperature and relative humidity (RH) ranges of 5°C to 40°C and 5% to 80% RH, non-condensing respectively, and under exceptional conditions up to +45°C, as described in [ETSI EN 300 019-1-3] Class 3.1. All vendors should indicate the maximum allowable temperature and humidity for all equipment, to maximize the efficiency opportunities in refrigeration and free cooling. It should be noted that where equipment with differing environmental requirements are not segregated, the equipment with the more restrictive temperature range will influence the cooling conditions and corresponding energy consumption for all ICT equipment. From 40°C to 45°C intake temperature, it is acceptable for equipment to implement performance reduction mechanisms to continue delivering the intended service at a lower speed whilst preventing damage. These mechanisms should not reduce performance to below 80% of the nominal for that device. Where such performance reduction mechanisms are used, a clear description of the operating parameters and performance impact should be provided. |
+| 7.1.4 | Environmental exclusions | Exclusions from the requirement for ICT equipment to meet the ETSI specification will be considered under the following specific conditions: – equipment that requires tighter environmental controls to meet the requirements of storage media such as tapes; – equipment that requires tighter environmental controls to meet long warranty durations (10+ years); – devices whose primary cooling method is not air (directly liquid cooled). These exclusions would require that equipment unable to meet best practice 7.1.3 should be deployed with separate airflow and cooling provision. This allows data centre cooling plants to be set up using equipment that has a less restrictive environmental range without compromising the eco-efficiency of the entire data centre. |
+| 7.1.5 | Multiple tender for ICT hardware – compliance with green regulations | Tender processes for new ICT equipment that are compliant with green regulations, will be considered as high-priority decision factors. Environmental pollution can be reduced by selecting equipment that is compliant with green regulations of each region or country (e.g., restrictions of hazardous substances (RoHS), registration, authorization and restriction of chemical substances (REACH), and waste electrical and electronic equipment (WEEE)). |
+
+| No. | Name | Description |
+|--------|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.1.6 | Select equipment suitable for the data centre – power density | Select and deploy equipment according to the defined power density (per rack or square metre) of the data centre to avoid running the cooling system outside design parameters.
Note that increasing power density may create cooling and airflow management problems, thereby reducing both capacity and efficiency. Power and cooling need to be considered as a capacity constraint in addition to a physical space constraint.
|
+| 7.1.7 | Select equipment suitable for the data centre – airflow direction | When selecting equipment for installation into racks, ensure that the airflow direction matches the airflow design for that area. This is commonly front-to-rear or front-to-top. If the equipment uses a different airflow direction to that defined for the area into which it is installed (such as right-to-left when the rack is intended to be front-to-back), then it should only be used with a correction mechanism such as ducts, or special racks that divert the airflow to the defined direction.
Uncorrected equipment with non-standard airflow will compromise the airflow management of the data centre, and therefore restrict temperature set points. It is possible to mitigate this issue by segregating such equipment.
|
+| 7.1.8 | Select free-standing equipment suitable for the data centre – airflow direction | When selecting equipment which is free-standing, or supplied in custom racks, the airflow direction of the enclosures should match the airflow design in that area of the data centre. This is commonly front to rear or front to top. Specifically, the equipment should match the hot/cold aisle layout or containment scheme implemented in the facility.
Uncorrected equipment with non-standard airflow will compromise the airflow management of the data centre and therefore restrict temperature set points. It is possible to mitigate this compromise by segregating such equipment.
Suggestions on airflow management are present in an annex to this Recommendation and in [ETSI TR 102 489].
|
+| 7.1.9 | Enable power management features | Formally change the deployment process to include the enabling of power management features on ICT hardware as it is deployed. This includes basic input-output system (BIOS), operating system and driver settings.
|
+| 7.1.10 | Provision to the as-configured power | Provision of power and cooling only to the as-configured power draw capability of the equipment, and not the power supply unit (PSU) or nameplate rating. Note that this may require changes to provisioning if the ICT equipment is upgraded internally.
|
+| 7.1.11 | Energy efficiency compliant hardware | ICT equipment with energy efficiency labels, such as the Energy Star labelling programmes, should be used as a guide to server selection when and where available for that class of equipment. Operators who are able to determine the in use energy efficiency of hardware through more advanced or effective analysis, should select the most efficient equipment for their scenario.
|
+| 7.1.12 | Energy and temperature reporting hardware | Select equipment with power and inlet temperature reporting capabilities, preferably reporting energy used as a counter in addition to power as a gauge. Where applicable, industry standard reporting approaches should be used, such as intelligent platform management interface (IPMI), data centre manageability interface (DCMI) and systems management architecture for server hardware (SMASH).
|
+
+| No. | Name | Description |
+|--------|-----------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | To assist in the implementation of temperature and energy monitoring across a broad range of data centres, all devices with an IP interface should support simple network management protocol (SNMP) polling of inlet temperature and power draw. Note that event based SNMP traps and SNMP configuration are not required. The intent of this practice is to provide energy and environmental monitoring of the data centre through normal equipment churn. |
+| 7.1.13 | Control of equipment energy use | Select equipment that provides mechanisms to allow the external control of its energy use. An example of this would be the ability to externally restrict a server's maximum energy use or trigger the shutdown of components, entire systems or sub-systems. |
+| 7.1.14 | Operating temperature range – liquid cooled ICT equipment | These devices should be able to operate with supply coolant liquid temperatures equal to the air temperatures specified in best practice 7.1.3, i.e., from 10°C to 35°C (50°F to 95°F). |
+| 7.1.15 | ICT equipment power against inlet temperature | When selecting new ICT equipment, require the vendor to supply at minimum, either the total system power or the cooling fan power for temperatures covering the full allowable inlet temperature range for the equipment under 100% load using a specified benchmark such as [b-SPECPower]. Data should be provided for 5°C or smaller steps of inlet temperature. |
+
+## 7.2 Selection of new telecom equipment
+
+Once ICT equipment is purchased and installed in the data centre, it typically remains in use for several years, consuming power and creating heat. The appropriate selection of hardware and deployment methods can provide significant long-term savings.
+
+| No. | Name | Description |
+|-------|-------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.2.1 | New equipment selection | Processes should be put in place to select new telecom equipment solutions that take into consideration the energy efficiency of the equipment and of the related infrastructure required for the correct operation of the telecom product. |
+
+## 7.3 Deployment of new ICT services
+
+The service architecture, software and deployment of ICT services have an impact at least as great as that of the ICT hardware.
+
+| No. | Name | Description |
+|-------|---------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.3.1 | Deploy using grid and virtualisation technologies | Processes should be put in place to require senior business approval for any new service that requires dedicated hardware and will not run on a resource-sharing platform. This applies to servers, storage and networking aspects of the service. This can improve available floor space, cost savings, rack utilization, ICT equipment utilization, and energy efficiency. |
+| 7.3.2 | Reduce ICT hardware resilience level | Determine the business impact of service incidents for each deployed service and deploy only the level of hardware resilience actually justified. |
+| 7.3.3 | Eliminate traditional 2N hardware clusters | Determine the business impact of short service incidents for each deployed service and replace traditional active/passive server hardware clusters with fast recovery approaches, such as restarting virtual machines elsewhere. (This does not refer to grid or high performance computer clusters.) |
+
+| No. | Name | Description |
+|-------|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.3.4 | Reduce hot/cold standby equipment | Determine the business impact of service incidents for each ICT service and deploy only the level of BC/DR standby ICT equipment and resilience that is actually justified by the business impact. |
+| 7.3.5 | Select/develop efficient software | Make the energy use performance of the software a significant selection factor. Whilst forecasting and measurement tools and methods are still being developed, approximations can be used such as the (under-load) power draw of the hardware required to meet performance and availability targets. If outsourcing software development, then consider the energy use of the software in the bonus/penalty clauses of the contract. |
+| 7.3.6 | Further development of software efficiency definitions | There is much research and development needed in the area of defining, measuring, comparing and communicating software energy efficiency.
Suggested examples are:
Software could be made resilient to delays associated with bringing off-line resources on-line, such as the delay of drive spin, which would not violate the service level requirements.
Software should not gratuitously poll or carry out other unnecessary background "housekeeping" that prevents equipment from entering lower-power states; this includes monitoring software and agents.
|
+
+## 7.4 Management of existing ICT equipment and services
+
+It is common to focus on new services and equipment to be installed in the data centre, but there are also substantial opportunities to achieve energy and cost reductions from within the existing service and physical installation.
+
+| No. | Name | Description |
+|-------|------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.4.1 | Audit existing physical equipment and services | Audit the existing physical equipment and services to establish what equipment is in place and what service(s) it delivers. Consider the implementation of an ITIL type configuration management database and service catalogue. |
+| 7.4.2 | Decommission unused ICT equipment/services | Completely decommission and remove the supporting hardware for unused ICT equipment/services. |
+| 7.4.3 | Decommission low business value services | Identify services whose business value is low and does not justify the financial or environmental cost. Decommission or archive these services. |
+| 7.4.4 | Shut down idle equipment | Servers, networking, and storage equipment that lie idle for a significant period of time, and cannot be virtualized and archived, should be shut down or put into a low power sleep mode. It may be necessary to validate the ability of legacy applications and hardware to survive these state changes without loss of function or reliability. |
+| 7.4.5 | Virtualize and archive legacy services | Servers which cannot be decommissioned for compliance or other reasons, but which are not used on a regular basis, should be virtualized and then the disk images archived to a low-power media. These services can then be brought online when actually required. |
+| 7.4.6 | Consolidation of existing services | Existing services that do not achieve high utilization of their hardware should be consolidated through the use of resource sharing technologies to improve the use of physical resources. This applies to servers, storage and networking devices. |
+
+| No. | Name | Description |
+|-------|--------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.4.7 | Control of system energy use | Consider resource management systems capable of analysing and optimizing where, when and how ICT workloads are executed, and their consequent energy use. This may include technologies that allow remote deployment or delayed execution of jobs, or the movement of jobs within the infrastructure, to enable shutdown of components, entire systems or sub-systems. The desired outcome is to provide the ability to limit localized heat output or to constrain system power draw to a fixed limit, at a data centre, row, rack or sub-DC level. |
+| 7.4.8 | Audit of existing ICT environmental requirements | Identify the allowable intake temperature and humidity ranges for existing ICT equipment. |
+
+## 7.5 Data management
+
+Storage is a major growth area in both cost and energy consumption within the data centre. It is generally recognized that a significant proportion of the data stored is either unnecessary or duplicated and does not require high performance access, and that this represents an organisational challenge. Some sectors have a particular issue due to very broad and non-specific data retention directions from governments or regulating bodies. Where there is little structure to the data storage, implementation of these regulations can cause large volumes of data that are not required by the regulations to be unnecessarily heavily protected and archived.
+
+| No. | Name | Description |
+|-------|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.5.1 | Data management policy | Develop a data management policy to define which data should be kept, for how long and at what level of protection. Communicate the policy to users and enforce it. Particular care should be taken to understand the impact of any data retention requirements. |
+| 7.5.2 | Separate user logical data storage areas by retention and protection policy | Provide users with multiple data storage areas that are clearly identified by their retention policy and level of data protection. Communicate this policy to users to enable them to store data in an area that matches the required levels of protection and retention. This is particularly valuable where strong retention requirements exist, as it allows data subject to those requirements to be separated at source, thereby presenting substantial opportunities for cost and energy savings. Where possible automate the application of these policies. |
+| 7.5.3 | Separate physical data storage areas by protection and performance requirements | Create a tiered storage environment utilising multiple media types that deliver the required combinations of performance, capacity and resilience. Implement clear guidelines on usage of storage tiers, with defined SLAs for performance and availability. Consider a tiered charging model based on usage at each tier. |
+| 7.5.4 | Select lower power storage devices | When selecting storage hardware, evaluate the energy efficiency in terms of the service delivered per watt between options. This may be deployment-specific and should include the achieved performance and storage volume per watt, as well as additional factors where appropriate, such as the achieved levels of data protection, performance availability and recovery capability required to meet the business service level requirements defined in the data management policy. Evaluate both the in-use power draw and the peak power of the storage device(s) as configured, both impact per device cost and energy consumption through provisioning. |
+
+| No. | Name | Description |
+|-------|-----------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 7.5.5 | Reduce total data volume | Implement an effective data identification and management policy and process to reduce the total volume of data stored. Consider implementing "clean up days" where users delete unnecessary data from storage. |
+| 7.5.6 | Reduce total storage volume | Implement the data management policy to reduce the number of copies of data, both logical and physical (mirrors). Implement storage subsystem space saving features, such as space efficient snapshots/copies or compression. Implement storage subsystem thin provisioning features where possible. |
+| 7.5.7 | Further development of storage performance and efficiency definitions | Storage performance has multiple dimensions, including throughput and latency, not all of which can be measured at the storage layer. Capacity also has multiple dimensions, allocation and usage, not all of which can be measured at the storage layer. Technologies such as de-duplication, compression, snapshots, and thin provisioning also need to be accounted for in a consistent and informative manner. |
+
+# 8 Cooling
+
+Cooling of the data centre is frequently the largest energy loss in the facility and as such represents a significant opportunity to improve efficiency.
+
+## 8.1 Airflow design and management
+
+The objective of airflow management is to minimize bypass air that returns to the computer room air conditioner (CRAC) units without performing its cooling function. The resultant recirculation and mixing of cool and hot air, increases the equipment intake temperatures. To compensate, CRAC unit air supply temperatures are frequently reduced, or airflow volumes are increased, which has an energy penalty. Addressing these issues will deliver more uniform equipment inlet temperatures and allow set points to be increased (with the associated energy savings), without the risk of equipment overheating. Implementation of air management actions alone does not result in energy saving – they are enablers which need to be tackled before set points can be raised.
+
+| No. | Name | Description |
+|-------|------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.1.1 | Design – contained hot or cold air | There are a number of design concepts which intend to contain and separate the cold air from the heated return air on the data floor:
– hot aisle containment; – cold aisle containment; – contained rack supply, room return; – room supply, contained rack return, (including rack chimneys); – contained rack supply, contained rack return. This action is expected for air-cooled facilities over 1 kW per square meter power density.
Note that the in-rack cooling options are only considered to be containment where the entire data floor area is cooled in rack, not in mixed environments where they return cooled air for remix with other airflow.
|
+
+| No. | Name | Description |
+|--------|---------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.1.2 | Design – hot/cold aisle | As the power densities and airflow volumes of ICT equipment have increased, it has become necessary to ensure that equipment shares an airflow direction, within the rack, in adjacent racks and across aisles.
The hot/cold aisle concept aligns equipment airflow to create aisles between racks that are fed cold air from which all of the equipment draws intake air in conjunction with hot aisles with no cold air feed, to which all equipment exhausts air.
|
+| 8.1.3 | Design – contained hot or cold air – retrofit | Where hot/cold aisle separation is already in use, but there is no containment of hot or cold air, it is possible to retrofit to provide basic separation.
|
+| 8.1.4 | Rack airflow management – blanking plates | Installation of blanking plates where there is no equipment to reduce cold air passing through gaps in the rack. This also reduces air heated by one device being ingested by another device, increasing intake temperature and reducing efficiency.
|
+| 8.1.5 | Rack airflow management – other openings | Installation of aperture brushes (draught excluders) or cover plates to cover all air leakage opportunities in each rack. This includes:
– floor openings at the base of the rack; – gaps at the sides, top and bottom of the rack between equipment or mounting rails and the perimeter of the rack. |
+| 8.1.6 | Rack airflow management – obstructions | The main cause of rack airflow obstruction is the cables behind racks. Unorganized cables may block hot airflow from ICT equipment and cause re-intake of the air by the rack front, further increasing the equipment inlet temperature. Therefore, cables behind racks should be organized to secure adequate amount of cold airflow.
|
+| 8.1.7 | Raised floor airflow management | Close all unwanted apertures in the raised floor. Review placement and opening factors of vented tiles. Maintain unbroken rows of cabinets to prevent bypass air – where necessary fill with empty fully blanked racks. Managing unbroken rows is especially important in hot and cold aisle environments. Any opening between the aisles will degrade the separation of hot and cold air.
|
+| 8.1.8 | Raised floor airflow management – obstructions | Review the placement and level of obstruction created by cabling, cable trays and other structures in the airflow paths to enable unobstructed airflow and prevent turbulence and increased resistance. The use of overhead cabling trays for signalling, for example, can substantially reduce the energy requirements for air movement.
|
+| 8.1.9 | Design – raised floor or suspended ceiling height | If, when designing a data centre, spaces are created by raising the floor level or suspending the ceiling, such air chambers are commonly used to feed cold air to equipment, or extract hot air from it. Where such voids are utilized, the increased spaces can significantly reduce fan loss in moving the air.
|
+| 8.1.10 | Design – return plenums | Consider the use of return dedicated ducts to return heated air from the ICT equipment to the air conditioning units.
|
+
+| No. | Name | Description |
+|--------|------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.1.11 | Design – perforated tiles | Mixed use of two or three perforated tiles with different aperture ratios is more advisable than using perforated tiles having the same aperture ratio in all spots of the computer room.
In general, areas closer to CRAC units have higher air volume and static pressure, which enables provision of a sufficient amount of cold air to ICT equipment, even with perforated tiles having low aperture ratios. In the areas farther from CRAC units, provision of cold air can be controlled by using perforated tiles with high aperture ratios.
It is recommended not to install perforated tiles in areas that are too close to CRAC units. In these areas, the fast airflow under the raised floor creates negative pressure on perforated tiles and causes Venturi reversal, in which the air above the raised floor is pulled down under. The Venturi reversal rather draws hot air to ICT equipment while causing a lack of cold air provision to the equipment.
|
+| 8.1.12 | Equipment segregation | Deploy groups of equipment with substantially different environmental requirements and/or equipment airflow direction in a separate area. Where the equipment has different environmental requirements, it is preferable to provide separate environmental controls.
The objective of this practice is to address the issue of the data centre cooling plant settings being constrained by the ICT equipment with the most restrictive environmental range, or poor airflow control, as this compromises the efficiency of the entire data centre.
|
+| 8.1.13 | Disposition of high-heat equipment | As energy consumption and heat from blade servers or large equipment increase, disposition of such high-heat equipment often affects the efficiency of the entire computer room. It is appropriate to position high-heat equipment in places where most cold air is provided.
– CRAC units are often installed facing each other in the computer room. In this situation, the air temperature is lowest in the centre of the room. Therefore, high-heat equipment should be installed in the centre of the computer room, rather than in places near CRAC units. – If it is uncertain which place receives the most amount of cold air, it is recommended to measure the temperature of each area and install the high-heat equipment in the place with the lowest temperature. |
+| 8.1.14 | Provide adequate free area on rack doors | Solid doors can be replaced (where doors are necessary) with partially perforated doors to ensure adequate cooling airflow within the enclosed cabinet further increasing the equipment intake temperature.
|
+
+| No. | Name | Description |
+|--------|------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.1.15 | Separate from external environment | The more contact the computer room has with the outer environment (outside air and solar heat), the more it is exposed to influences on temperature and humidity, further decreasing the entire air conditioning efficiency. Therefore, blocking contacts with the outer environment is a significant factor that is directly related to reducing energy consumption.
For separation from the external environment, the following activities are required:
• designing a windowless room or sealing windows; • installing double doors or an automatic door; • restricting entry/exit of unnecessary persons; • blocking channels connected to the outside, such as an outlet, etc. To prevent temperature increase from solar heat in the computer room, it is necessary to deploy a windowless design or shield windows (by way of window shades, curtains, solar screen panels, etc.)
|
+
+## 8.2 Cooling management
+
+The data centre is not a static system and the cooling systems should be tuned in response to changes in the facility thermal load.
+
+| No. | Name | Description |
+|-------|---------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.2.1 | Scalable or modular installation and use of cooling equipment | Cooling plants should be installed in a modular fashion allowing operators to shut down unnecessary equipment. This should then be part of the review at each cooling load change. |
+| 8.2.2 | Shut down unnecessary cooling equipment | If the facility is not yet fully populated or space has been cleared through consolidation, non-variable plants, such as fixed speed fan CRAC units, can be turned off in the empty areas.
Note that this should not be applied in cases where operating more plants at a lower load is more efficient, e.g., variable speed drive CRAC units.
|
+| 8.2.3 | Review of cooling before ICT equipment changes | The availability of cooling, including the placement and flow of vented tiles, should be reviewed before each ICT equipment change to optimize the use of cooling resources. |
+| 8.2.4 | Review of cooling strategy | Periodically review ICT equipment and cooling deployment against strategy. |
+| 8.2.5 | Review CRAC/air handling unit (AHU) settings | Ensure that CRAC/AHU units in occupied areas have an appropriate and consistent temperature, and relative humidity settings, to avoid units working against each other. For example, many CRAC/AHU units now have the option to connect their controls and run together when installed in the same area. |
+| 8.2.6 | Dynamic control of building cooling | It is possible to implement control systems that take many factors into account, including cooling load, data floor air temperature and external air temperature, to optimize the cooling system (e.g., chilled water loop temperature) in real time. |
+| 8.2.7 | Effective regular maintenance of cooling plant | Effective regular maintenance of the cooling system is essential to maintain the design operating efficiency of the data centre, e.g., belt tension, condenser coil fouling (water or air side), evaporator fouling, filter changes, etc. |
+
+| No. | Name | Description |
+|-------|--------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.2.8 | Evaporative cooling method and the spot cooling method | Evaporative cooling method and the spot cooling method were proposed as best practice for data centres, with high-density ICT devices (see Annex B). |
+
+## 8.3 Temperature and humidity settings
+
+Facilities are often over-cooled, bringing about air temperatures (and hence chilled water temperatures, where used) that are colder than necessary and resulting in an energy penalty. Increasing the set range for humidity can substantially reduce humidifier loads. Reviewing and addressing air management issues is required before set points can be changed in order to avoid risk to operational continuity. Expert advice should be sought before changing the environmental range for the facility. An increase in chilled water temperature set points provides enhanced efficiency for free cooling economizers and a reduction in compressor energy consumption. Unnecessary humidifier loads, generated by water loop or evaporator temperatures below the working dew point causing dehumidification-humidification loops, should be eliminated through adjustment of the lower humidity set point.
+
+The specification of wider operating humidity and temperature ranges for the data floor should be performed in conjunction with changes in ICT equipment procurement policy. Over time, narrow tolerance equipment will be naturally cycled out and replaced.
+
+| No. | Name | Description |
+|-------|-------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.3.1 | Expanded ICT equipment inlet environmental conditions (temperature and humidity) High priority practices | Where appropriate and effective, the data centre can be designed and operated within the air inlet temperature and relative humidity ranges of 5°C to 40°C and 5% to 80% RH, non-condensing respectively, and under exceptional conditions up to +45°C as described in [ETSI EN 300 019-1-3], Class 3.1. It is necessary to consider that some ICT equipment may exhibit significant increases in fan energy consumption as intake temperature is increased (e.g., above 25°C). Validate that your ICT equipment will not consume more energy than is saved in the cooling system. |
+| 8.3.2 | Review and, if possible, raise target ICT equipment intake air temperature Low priority practices | Data centres should be designed and operated at their highest efficiency within the current environmental range of 18°C to 32°C. This is defined by ASHRAE as allowable for class 1 data centres [b-ASHRAE TC 9.9]. Operations in this range enable energy savings by reducing or eliminating over-cooling. This range applies to legacy data centres with existing equipment. Note that other best practices for airflow management (containment, hot aisle/cold aisle, blanking plates, and sealing leaks) may need to be implemented at the same time to ensure successful operations. |
+| 8.3.3 | Review and increase the working humidity range Low priority practices | Reduce the lower humidity set point(s) of the data centre within the range (5.5°C dew point) to eliminate loop dehumidification and re-humidification. Review and, if practical, increase the upper humidity set point(s) of the data floor within the current environmental range of 20°C dew point and 80% RH to decrease the humidity control loads within the facility. |
+
+| No. | Name | Description |
+|-------|----------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.3.4 | Review set points of air and water temperatures | Once air management issues have been addressed and ICT equipment target temperatures have been agreed upon, these temperatures can be increased (using less energy), without increasing server inlet temperatures beyond acceptable levels. It is necessary to consider that some ICT equipment may exhibit significant increases in fan energy consumption as intake temperature is increased (e.g., above 25°C). Validate that your ICT equipment will not consume more energy than is saved in the cooling system. |
+| 8.3.5 | Review and, if possible, raise chilled water temperature | Review and, if possible, increase the chilled water temperature set points to maximize the use of free cooling economizers and reduce compressor energy consumption. Where a direct expansion (DX) system is used, the evaporator temperatures should be reviewed. |
+| 8.3.6 | Control to a humidity range | Controlling humidity within a range of humidity ratio or relative humidity can reduce humidification and dehumidification loads. |
+
+#### 8.3.1 Free and economized cooling
+
+Free, or economized cooling designs, use cool ambient conditions to meet part, or all, of the facilities cooling requirements. Hence, compressor work for cooling is reduced or removed, which can result in significant energy reduction. Economized cooling can be retrofitted to some facilities. The opportunities for the utilization of free cooling are increased in cooler climates and where increased temperature set points are used.
+
+| No. | Name | Description |
+|---------|------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.3.1.1 | Direct air free cooling | External air is used to cool the facility. Chiller systems are present to deal with humidity and high external temperatures, if necessary. Exhaust air is re-circulated and mixed with intake air to avoid unnecessary humidification/dehumidification loads. |
+| 8.3.1.2 | Indirect air free cooling | Re-circulated air within the facility is primarily passed through a heat exchanger against external air, to remove heat to the atmosphere. |
+| 8.3.1.3 | Direct water free cooling | Chilled water cooled by the external ambient air, via a free cooling coil, may be achieved by dry (adiabatic) coolers, or by evaporative assistance through spray onto the dry (adiabatic) coolers. |
+| 8.3.1.4 | Indirect water free cooling | Chilled water is cooled by the external ambient conditions via a heat exchanger which is used between the condenser and chilled water circuits. This may be achieved by dry (adiabatic) coolers, evaporative assistance through spray onto the dry (adiabatic) coolers or cooling towers. |
+| 8.3.1.5 | Sorption cooling (absorption/adsorption) | Waste heat, produced close to the data centre as a by-product of power generation or other processes, is used to power the cooling system in place of electricity. This is frequently part of a tri-generation (Tri-Gen) combined cooling heat and power system. These systems should be assessed for viability over their full lifetime against an optimized, economically efficient cooling plant. |
+
+#### 8.3.2 High efficiency cooling plant
+
+The next preferred cooling technology is the use of high-efficiency cooling plants. Designs should operate efficiently at system level and employ efficient components. This demands an effective control strategy, which optimizes efficient operation, without compromising reliability.
+
+| No. | Name | Description |
+|---------|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.3.2.1 | Select adequate cooling methods of CRAC units | Methods of cooling CRAC units mainly consist of air-cooling, water-cooling, and chilled water-cooling. The costs for initial installation, operation and purchasing of CRAC units may significantly depend on which method is selected. This is why the most optimal method should be chosen after considering the features, strengths and weaknesses of each method as well as the data centre environment.
– In general, using the air-cooling method is recommended for small-sized computer rooms (with less than 10 CRAC units), as long as the conditions allow for this. – For mid- or large-sized computer rooms (with 10 or more CRAC units), it is recommended to use either chilled water or a water-cooling method, depending on the building conditions. (This will save operational costs.) |
+| 8.3.2.2 | Select adequate cooling towers | Cooling towers are used to exchange inside heat with outside air under water or chilled water cooling methods and are largely divided into a closed type and an open type. It is recommended to select closed cooling towers, built solely for ICT equipment despite the high installation cost.
|
+| 8.3.2.3 | Chillers with high coefficient of performance (COP) | Make the COP of chiller systems through their likely working range a high priority decision factor during procurement of a new plant.
|
+| 8.3.2.4 | Select adequate refrigerants | Refrigerants are used inside air-cooled and water-cooled CRAC units to discharge inside heat effectively. Each type of the refrigerants (R-22, R-134a, R-404a, R-407c, R-410a, etc.) has different prices, cooling efficiency and legal restrictions. Therefore, the most appropriate one should be selected after considering the strengths and weaknesses of each refrigerant.
– Serious consideration is especially required with regard to using R-22, for it may destroy the ozone layer and be restricted by international regulations. |
+| 8.3.2.5 | Cooling system operating temperatures | Evaluate the opportunity to decrease the condensing temperature or increase the evaporating temperature; reducing the difference between these temperatures means less work is required in the cooling cycle, hence improving efficiency. These temperatures are dependent on required internal air temperatures (see clause 8.3).
|
+| 8.3.2.6 | Efficient partial load operation | Optimize the facility for the partial load – it will persist for most of the operational time, rather than for the maximum load. e.g., sequence chillers, operate cooling towers with a shared load for an increased heat exchange area.
|
+| 8.3.2.7 | Variable speed drives for compressors, pumps and fans | Reduce energy consumption for these components in the partial load condition, where they operate for much of the time.
|
+| 8.3.2.8 | Select systems which facilitate the use of economizers | Select systems which facilitate the use of cooling economizers. In some buildings it may be possible to use air-side economizers. Others may not have sufficient space available, and may require a chilled liquid cooling system to allow effective use of economized cooling.
|
+
+| No. | Name | Description |
+|----------|-------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.3.2.9 | Selection of adequate cooling methods considering space efficiency | Four air conditioning methods are available for the typical data centre:
1) Conventional air conditioning cools by supplying the entire room with cold air, cooled with chilled water from a chilling system, which flows through perforated tiles on the floor's surface. Energy consumption of both the water chilling units and the blower that circulates the chilled air through the entire room is high. 2) The outdoor air cooling method introduces cold air from outdoors directly into the room for cooling, permitting a reduction in the chilling system's energy consumption. This system can be envisaged when the outdoor temperature is higher than -30^{\circ}\text{C} but lower than the room temperature. 3) The evaporative cooling method sprays water into cold outdoor air, and cools by heat exchange between the cooled air and the return air from the room, permitting a reduction in the chilling system's power consumption. This system can be envisaged when the outdoor temperature is higher than -5^{\circ}\text{C} but lower than the room temperature. 4) The spot cooling method employs spot cooling units on top of racks (in ceiling) for local cooling and cools high temperature exhaust air from the servers around the server racks. Space efficiency of a data centre is influenced by its power density. Space efficiency indicates the ratio of floor area employed for ICT equipment to the total floor area of the building. The higher the value, the smaller the floor area occupied by the air conditioning equipment, and the more effective the use of the floor area. Power density indicates the energy consumption of ICT equipment per rack/cabinet of the server room floor area. As the power density of a data centre increases, the footprint for the air conditioning system and the required height of the floor chamber will also increase, affecting the initial cost because of architectural structural changes. On the other hand, the footprint of a spot cooling system does not increase based on power density, because cooling units are implemented on server racks.
In the case of data centres with high power density (e.g., higher than 5-6 kW/racks, or 8 kW in the case of a high raised floor), a spot cooling system should be selected based on space efficiency.
Suggestions on possible climatic range for the selection of adequate cooling methods can be found in [b-ITU-T Val]
|
+| 8.3.2.10 | Selection of adequate cooling methods considering outdoor air condition | The wet-bulb temperature of outdoor air affects the energy consumption of a cooling system. Wet-bulb temperature is the indication of the energy condition of air switches.
When the wet-bulb temperature for a location is lower, energy consumption for the outdoor air cooling and evaporative cooling method is reduced due to effective use of cold outdoor air.
In a location where the wet-bulb temperature of outdoor air is low, the energy efficiency of these cooling systems becomes higher than conventional systems. On the other hand, when the wet-bulb temperature of outdoor air is high, the energy efficiency of spot cooling systems becomes higher than conventional systems due to the effect of the reduction of distribution power, such as fans and pumps.
|
+
+| No. | Name | Description |
+|----------|---------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | In the case of a data centre location with a low wet-bulb temperature (e.g., lower than 15°C), the outdoor air-cooling method, or the evaporative cooling method, should be selected based on energy efficiency. (This type of indication considers both temperature and humidity conditions).
Also, in the case of a data centre location with a high wet-bulb temperature (e.g., higher than 15°C), the spot cooling method should be selected based on its energy efficiency.
It is necessary to consider that in some locations it is useful to implement not only one of the previous techniques (see best practice 8.3.2.9), but a combination of different technologies.
|
+| 8.3.2.11 | Selection of energy and space efficient cooling system | The power density of a data centre affects cooling system space efficiency and has a big impact on initial costs. Also, the outdoor air condition impacts the energy efficiency of a cooling system.
We should consider these two factors when selecting an efficient cooling method.
If the data centre is located in a warmer zone (e.g., higher than 15°C), a spot cooling system should be selected because of its advantages with regard to maximum space efficiency and maximum energy efficiency.
|
+| 8.3.2.12 | Do not share data centre chilled water system with comfort cooling | Do not share the data centre chilled water system with comfort cooling in other parts of the building.
The required temperature to achieve latent cooling for comfort cooling is substantially below that required for sensible cooling of the datacentre and compromises the efficiency of the datacentre cooling system.
|
+| 8.3.2.13 | Do not allow non ICT equipment to dictate cooling system set-points | Where other equipment requires a more restrictive temperature or humidity control range than the ICT equipment this should not be permitted to dictate the set points of the cooling system responsible for the ICT equipment.
|
+
+## 8.4 Computer room air conditioners
+
+The second major component of most cooling systems is the air conditioner units within the computer room. The computer room side of the chiller plant in older facilities is frequently poorly designed and poorly optimized.
+
+| No. | Name | Description |
+|-------|----------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.4.1 | Select adequate CRAC units | There are many criteria for selecting a CRAC unit – cooling capacity, operational conditions (dry-bulb temperature and relative humidity), amount of airflow, etc. – and the process should be taken seriously from a long-term point of view, because the life span of a CRAC unit ranges from 7 to 15 years after installation.
– In many cases, refrigerant ton (RT) is mainly considered when determining the cooling capacity of a CRAC unit. However, CRAC units having the equivalent RT level may have different cooling capacities, depending on the manufacturer. Therefore, units such as kcal/h or kW, rather than RT, should be considered when measuring the cooling capacity (1RT = 3 024 kcal/h, 1 kW/h = 860 kcal/h). – Among many CRAC units having the equivalent level of cooling capacity, it is recommended to select those with lower dry-bulb temperatures (hot air temperature returned into the CRAC unit) because they have a higher cooling capacity. – Relative humidity of returned air into the CRAC units also affects cooling capacity. Because manufacturers of CRAC units specify the cooling capacity of each product under a certain level of relative humidity, it is necessary to compare them under the same relative humidity conditions. – The amount of airflow is related to the size of motors in CRAC units and therefore should not always be large. The larger the amount of airflow, the more energy is consumed, and it is important to select the optimal amount of airflow. |
+| 8.4.2 | Variable speed fans | Many old CRAC units operate fixed speed fans which consume substantial power and obstruct attempts to manage the data floor temperature.
Variable speed fans are particularly effective where there is a high level of redundancy in the cooling system, low utilization of the facility or highly variable ICT electrical load. These fans may be controlled by factors such as the return air temperature or the chilled air plenum pressure.
Note that CRAC units with fixed speed compressors have minimum flow requirements which constrain the minimum operating load.
|
+| 8.4.3 | Calculate adequate cooling capacity and quantity of CRAC units | The cooling capacity and quantity of CRAC units are measured mostly based on the expected amount of heat from ICT equipment, and partly based on the safety factor. However, more factors should be accurately determined in addition, such as the location of computer rooms and the amount of load from solar heat.
|
+| 8.4.4 | Disposition of CRAC units | The most important thing to be considered when installing a CRAC unit is that the focus should be put more on facilitating hot air return than on providing cold air. Returning of hot air depends on the location of the CRAC unit and has a great influence on the temperature and humidity of the computer room. When the installation structure of ICT equipment consists of a cold aisle and a hot aisle, the best place for CRAC unit disposition will be the end of the hot aisle, where the unit shall be placed in a vertical direction. This is very important in that it will help secure the shortest route for heated air to return to the CRAC unit without affecting racks. If a CRAC unit is placed in the same direction as the racks, the heated air returning to the CRAC unit will affect the row of racks located behind the unit.
|
+
+| No. | Name | Description |
+|--------|---------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.4.5 | Run variable speed CRAC units in parallel | It is possible to achieve efficiency gains by running CRAC units with variable speed fans in parallel to reduce the total electrical power necessary to achieve the required air movement, as electrical power is not linear with airflow. Care should be taken to understand any new failure modes or single points of failure that may be introduced by any additional control system. |
+| 8.4.6 | Sequencing of CRAC units | In the absence of variable speed fans, it is possible to turn entire CRAC units on and off to manage the overall airflow volumes. This can be effective where there is a high level of redundancy in the cooling system, low utilization of the facility or highly variable ICT electrical load. |
+| 8.4.7 | Management of back-up CRAC units | Failure of one CRAC unit may significantly increase the temperature in several zones. This is because even with the sufficient capacity of the entire CRAC unit in a computer room, there are limitations to the processing coverage of each CRAC unit. Therefore, installation of back-up CRAC units needs to be considered, based on the fact that a back-up CRAC unit should be placed for each zone that can be covered by one CRAC unit ( $N+1$ ). In general, one back-up CRAC unit is recommended for 5-6 CRAC units. However, conditions may vary and it would be advisable to carry out a simulation test based on a computational fluid dynamics (CFD) analysis prior to installation. Setting only one CRAC unit for back-up operation is not recommended due to its impact on even consumption of parts, lifecycle of the CRAC unit, and uncertainties in case of emergency. Therefore, it is better to take turns on regular cycles and make all CRAC units run for a certain period of time. (Naturally, the conditions of all units can be checked.) |
+| 8.4.8 | Control on CRAC unit supply air temperature | Controlling supply temperature ensures that the server supply air (SA) (key temperature to control) is satisfactory, without possible over-cooling of air which may result when controlling return temperature (where sensor location may impact). |
+| 8.4.9 | Direct liquid cooling of ICT devices | In the place of chilling air, it is possible to directly liquid cool part or all of some ICT devices. This can provide a more efficient thermal circuit and allow the coolant liquid system temperature to be substantially higher, further improving efficiency, and allowing for increased or exclusive use of free cooling or heat re-use. Note that this practice applies to devices which deliver cooling fluid directly to the heat removal system of the components, such as water-cooled heat sinks or heat pipes, and not the delivery of cooling liquid to an internal mechanical refrigeration plant or in chassis air cooling systems. |
+| 8.4.10 | Do not control humidity at CRAC unit | Humidity control at the CRAC unit is unnecessary and undesirable. Do not control humidity at the CRAC unit on recirculating air instead control the specific humidity of the make-up air at the supply AHU. The chilled water loop or DX evaporator temperature should in any case be too high to provide de-humidification. |
+
+## 8.5 Re-use of data centre waste heat
+
+Data centres produce significant quantities of waste heat. Whilst this is typically at a relatively low temperature, there are some applications for the re-use of this energy. As ICT equipment is increasingly used through consolidation and virtualisation, the exhaust temperature is likely to increase, thus providing greater opportunity for waste heat to be re-used. Direct liquid cooling of ICT equipment can further reduce any detrimental impact on the environment by utilizing the capacity of coolant to provide heat.
+
+| No. | Name | Description |
+|-------|--------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 8.5.1 | Waste heat re-use | It may be possible to provide low grade heating to industrial space, or to other targets such as swimming pools, directly from heat rejected from the data centre. This recycling can ameliorate energy use elsewhere, reducing the total energy use of the data centre and the client using the waste heat. |
+| 8.5.2 | Heat pump assisted waste heat re-use | Where it is not possible to directly re-use the waste heat from the data centre due to the temperature being too low, it can still be economic to use additional heat pumps to raise the temperature to a useful point. For example, this can supply heating for offices or the district utilities. |
+| 8.5.3 | Use data floor waste heat to warm generator and fuel storage areas | Reduce or eliminate the electrical preheat loads for generators and fuel storage by using warm exhaust air from the data floor to maintain temperature in the areas housing generators and fuel storage tanks. |
+
+# 9 Data centre power equipment
+
+The other major part of the facility infrastructure is the power conditioning and delivery system. This normally includes UPSs, power distribution units (PDUs), and cabling, but may also include backup generators and other equipment.
+
+## 9.1 Selection and deployment of power equipment
+
+Power delivery equipment has a substantial impact upon the efficiency of the data centre and tends to remain operational for many years once installed. Careful selection of power equipment at the design stage, can deliver substantial savings throughout the lifetime of the facility.
+
+| No. | Name | Description |
+|-------|---------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 9.1.1 | Power equipment with consideration of further extension | Power equipment such as power reception/distribution/transformation systems, and cabinet panels can be extended phase-by-phase. To extend the power equipment, energy consumption data of the entire data centre should be monitored to an accurate level and the room for extension must be planned in the first place.
Cabinet panels, which are the most sensitive to extension or transformation of ICT equipment, have a significant influence on the power capacity, space, and amount of airflow of CRAC units. Therefore, extra sub-circuit breakers should be prepared for cabinet panels in case of ICT equipment extension, and extra circuit breakers should be prepared for the main cabinet panels that are for extending sub-cabinet panels.
The need for extensions should be considered at the design stage.
|
+
+| No. | Name | Description |
+|-------|---------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 9.1.2 | Modular UPS deployment | It is now possible to purchase modular (scalable) UPS systems across a broad range of power delivery capacities. Physical installation, transformers and cabling are prepared to meet the design electrical load of the facility but the sources of inefficiency, (such as switching units and batteries), are installed, as required, in modular units. This substantially reduces both the capital cost and the fixed overhead losses of these systems. In low power environments, these may be frames with plug in modules, whilst in larger environments these are more likely to be entire UPS units. |
+| 9.1.3 | High efficiency UPS | High efficiency UPS systems of any technology, including electronic or rotary, should be selected to meet site requirements. |
+| 9.1.4 | Use efficient UPS operating modes | UPS should be deployed in their most efficient operating modes, such as line interactive. Technologies such as rotary and high voltage direct current (DC) can also show improved efficiency, as there is no dual conversion requirement. |
+| 9.1.5 | Efficient battery selection and deployment | Select batteries that are eco-friendly (free from hazardous substances and heavy metal). Moreover, select those that are less likely to be self-discharged and that consume less charging power. Extending the back-up time of the batteries to longer than 30 minutes for securing availability of the data centre is unnecessary. Instead, it is recommended to design 15-20 minute battery back-up time, depending on the field conditions. |
+| 9.1.6 | Up to 400 V DC power distribution | Consider the use of up to 400 V DC power distribution within the data centre. This can reduce the overall power conversion and distribution losses within the facility. |
+| 9.1.7 | Power reception, distribution and transformation system | Selection of the method of power reception and transformation between one-step and two-step methods may vary according to the characteristics of the data centre. However, selecting the one-step vertical drop method is recommended to reduce no-load loss of electrical transformers. In addition, application of one method to all systems can also be possible to prevent undue financial investment incurred by excessive duplex configuration and an increase in the amount of power consumed.
– Use highly efficient switch gears and electrical transformers. – Use active filters to improve power quality and reduce power loss. – Use tuned and de-tuned filters to improve harmonics and power factors. – Deploy peak power control systems to efficiently use electrical power and manage peak power in a reasonable manner. |
+
+| No. | Name | Description |
+|--------|------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 9.1.8 | Cabinet panel deployment | With the increasing amount of power consumption by ICT equipment, cabinet panel deployment should satisfy the following conditions:
– Provide single-phase power to each server rack with a power requirement of 4 kW or less. – If server racks have power requirements of more than 4 kW, providing three-phase power to rack-typed and measurable cabinet panels will be more efficient. – Power supply can be made easier by installing a rack-typed cabinet panel next to each server rack, which can also contribute to easier facility extension in the case of an increase in the number of ICT equipment (the more three-phase breakers, the easier equipment extension will be in the future). – This method also needs fewer cables than when providing power supply from cabinet panels to each server rack, which will further facilitate cooled air provisioning under the raised floor and reduce harmonics and heating of neutral conductors by maintaining load balance. |
+| 9.1.9 | Power distribution unit (PDU) deployment | Specifications of PDUs should be differentiated according to the power capacity demanded by servers. As there are an increasing number of high-capacity servers, it is impossible to deploy a common PDU to all servers but PDUs should be customized to each in-rack server and installed.
|
+| 9.1.10 | Use new and renewable energy | Actively consider use of new renewable energies to cope with the increasing energy cost and the amount of carbon emissions.
– New renewable energies include, fuel cell and hydrogen energy, which are based on new physical power and new substances. – Renewable energies include solar thermal energy, solar photovoltaic energy, biomass, wind power, tidal power, hydraulic, and geothermal power generation. |
+| 9.1.12 | Elimination of isolation transformers | For the energy saving of data centre, isolation transformers in power distribution to ICT equipment are typically not required and should be eliminated from designs as they introduce additional transformer losses.
|
+
+## 9.2 Management of power equipment
+
+| No. | Name | Description |
+|-------|------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 9.2.1 | Optimal power density | Guideline recommendations on the most efficient range for power density.
|
+| 9.2.2 | Reduce engine-generator heater temperature set-point | When using engine heaters to keep generators ready for rapid starts, consider reducing the engine heater set-point. Block heaters for the standby generators should be controlled to operate only when the temperature conditions warrant it.
|
+
+| No. | Name | Description |
+|-------|--------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 9.2.3 | Wiring of power cables | All power cables connected to ICT equipment should be wired under the raised floor and the cables must not be installed in the cold aisle to prevent blocking of cold air for CRAC units. In exceptional cases cable wiring can be placed above the ceiling when it is high enough.
In order to prevent any failures (electromagnetic interference, noise, optical cable damage, etc.) caused by installing power cables and communication cables together under the raised floor, it is necessary to set up power cables under the raised floor before installing communication trays on the floor. EMC aspects shall be considered. Separating power cables and other wires will allow easier identification and management of them and improve efficiency in air conditioning.
|
+| 9.2.4 | Power factor management | Considering that the higher the power factor, the lower the proportion of reactive power – and thus, the less power loss; it is recommended to use independent equipment that can maintain the power factor at the most appropriate level.
– Using de-tuned filters is the least costly yet the most reasonable way to lower harmonics and improve power factor in electric power systems. |
+| 9.2.5 | Load balance management | The current value of each phase reaching the load at the end of the electrical transformer in fact varies from each other. Intensified imbalance may cause an excessive load level and heating in the power distribution system and joint parts. This can be a serious threat to safety and ultimately bring about unnecessary energy consumption. Therefore, not only the entire amount of electricity used, but also the amount of energy consumed in each phase, should be monitored at the same time.
|
+| 9.2.6 | Heat management on joint parts | Heat is generated on parts where there is an increasing level of resistance in power distribution and arrangement system. The main causes of such increasing resistance are equipment malfunction, loose connection, and current level exceeding the stable capacity level. If the heat is left unmanaged, it can lead to fire, thereby threatening data centre stability. Since the energy loss caused by the heat is also too great to be neglected, regular check-ups and fastening of joint parts is necessary. In most cases, thermal burn cameras are used to monitor abnormal heating.
|
+
+# 10 Other data centre equipment
+
+Energy is also used in the non-data floor areas of the facility, in office and storage spaces. Energy efficiency in non-data centre areas should be optimized based on relevant building standards, such as relevant EU standards, leadership in energy and environmental design (LEED), building research establishment environmental assessment methodology (BREEAM), etc.
+
+## 10.1 General practices
+
+These general practices apply to the data floor and may be extended to the remainder of the building if no sustainable building standard is in use.
+
+| No. | Name | Description |
+|--------|---------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 10.1.1 | Turn off lights | Lights should be turned off, preferably automatically, whenever areas of the building are unoccupied, for example, by switches that turn off lighting within a specified time following manual activation. Motion-detector activated lighting is generally sufficient to support security camera systems. |
+| 10.1.2 | Low energy lighting | Low energy lighting systems should be used in the data centre. |
+
+# 11 Data centre building
+
+The location and physical layout of the data centre building is important to achieving flexibility and efficiency. Technologies, such as fresh-air cooling, require significant physical plant space and air duct space that may not be available in an existing building.
+
+## 11.1 Building physical layout
+
+The physical layout of the building can present fundamental constraints on the applicable technologies and achievable efficiencies.
+
+| No. | Name | Description |
+|--------|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 11.1.1 | Locate M&E plant outside the cooled area | A heat-generating mechanical and electrical plant should be located outside the cooled areas of the data centre wherever possible, to reduce the loading on the data centre cooling plant. |
+| 11.1.2 | Select a building with sufficient ceiling height | Insufficient ceiling height in the data centre will obstruct the use of efficient air-cooling technologies, such as raised floor, and suspended ceiling or ducts. |
+| 11.1.3 | Optimize orientation of the data centre | Optimize the layout and orientation of the building to reduce insulation heat loads and optimize the efficiency of heat transfer. |
+| 11.1.4 | Facilitate the use of economizers | The physical layout of the building should not obstruct the use of economizers (either air or water). |
+| 11.1.5 | Location and orientation of plant equipment | Cooling equipment, particularly dry (adiabatic) coolers, should be located in an area of free air movement to avoid trapping it in a local hot spot. Ideally, this equipment should also be located in a position on the site where the waste heat does not affect other buildings and create further demand for air conditioning. |
+| 11.1.6 | Minimize insulation heating | Minimize solar heating of the cooled areas of the data centre by providing shade or increasing the albedo of the building through the use of light-coloured roof and wall surfaces. Shade may be constructed, or provided by trees or "green roof" systems. Low e-coating, which deposits a thin metal film on a glass surface, reflects radiant heat to the inside of the room in cold weather and to the outside in hot weather. Low e-coating on double-glazed glass will reduce cooling or heating expenditure as effectively as more costly transparent triple-glazed glass. |
+
+| No. | Name | Description |
+|---------|----------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 11.1.7 | Other technologies for energy efficient building – double skin | Double skin technology uses the air convection between the outside and the inside of the room by making a layer of space in between. In summer, the air heated inside the double skin rises and is emitted, carrying the heated air inside the room with it and further lowering the temperature. On the other hand, the air cooled inside the double skin flows into the room, leading to energy savings. |
+| 11.1.8 | Other technologies for energy efficient building – light shelf | A light shelf is energy-saving lighting equipment which uses the solar light reflected from a shelf installed in the top-lower part of the vertical window into the room. The most efficient distance range for using the natural light in a room is 4-6 metres from the window. Natural light has better luminous efficiency in terms of light quality than artificial light. The light shelf is also easy to build and can achieve a quality lighting environment and energy saving at lower cost. |
+| 11.1.9 | Utilize heavy water | Utilizing grey water means the use of advanced treatment of sewage water, such as waste water, river water and groundwater, so as to provide water for non-drinking purposes (e.g., flush toilets, cooling air conditioners, cleaning, sprinkling, landscaping and fire-fighting). An eco-friendly data centre which uses the grey water system reduces river pollution by decreasing the amount of newly-produced sewage water as much as the grey water used. In addition, it can save a significant amount of water for enabling data centres, mostly using a large amount of water, to reduce cooling water consumption. In general, grey water can be easily recycled as cooling water after being filtered and chlorinated only. |
+| 11.1.10 | Utilize rainwater | Utilizing rainwater means collection, filtering and storing the rainwater on the roof and then using it for non-drinking purposes. |
+| 11.1.11 | Other water sources | Use of other local non-utility water sources for evaporative cooling or other non-potable purposes may reduce overall energy consumption |
+| 11.1.12 | Metering of water consumption | The site should meter water consumption from all sources. The site should seek to use this data to manage and reduce overall water consumption. Note that water consumption cannot be directly compared with energy efficiency (PUE) unless the energy intensity of the water source is understood. Comparing water consumption between buildings is therefore not useful. |
+
+## 11.2 Building geographic location
+
+Whilst some operators may have no choice of the geographic location for a data centre, it nevertheless impacts achievable efficiency, primarily through the impact of the external climate.
+
+| No. | Name | Description |
+|--------|--------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 11.2.1 | Locate the data centre where waste heat can be re-used | Locating the data centre in places where there are available uses for waste heat can save substantial energy globally. For example, heat recovery can be used to heat office or industrial space, hydroponic farming and even swimming pools. |
+
+| No. | Name | Description |
+|--------|---------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 11.2.2 | Locate the data centre in an area of low ambient temperature | Free and economized cooling technologies are more effective in areas of low ambient external temperature and/or humidity. Note that most temperature climates, including much of Northern, Western and Central Europe, present significant opportunity for economized cooling. |
+| 11.2.3 | Avoid locating the data centre in high ambient humidity areas | Free cooling is particularly impacted by high external humidity as dehumidification becomes necessary; many economizer technologies are also less effective. |
+| 11.2.4 | Locate near a source of free cooling | Locating the data centre near a source of free cooling, such as a river, subject to local environmental regulation. |
+| 11.2.5 | Co-locate with power source | Locating the data centre close to the power generating plant can reduce transmission losses and provide the opportunity to operate sorption chillers from power source waste heat. |
+
+# 12 Monitoring
+
+The development and implementation of an energy monitoring and reporting management strategy is core to operating an efficient data centre.
+
+## 12.1 Energy use and environmental measurement
+
+Most data centres currently have little or no energy use or environmental measurement capability. Many do not even have a separate utility meter or bill. The ability to measure energy use and factors impacting energy use is a prerequisite to identifying and justifying improvements. It should also be noted that measurement and reporting of a parameter may also include alarms and exceptions if that parameter passes outside of the acceptable or expected operating range.
+
+| No. | Name | Description |
+|--------|-------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.1.1 | Incoming energy consumption meter | Install metering equipment capable of measuring the total energy use of the data centre, including all power conditioning, distribution and cooling systems. Again, the measured energy shall be separate from any non-data centre building loads. Note that this shall be required for an energy efficiency meter indicator. |
+| 12.1.2 | ICT energy consumption meter | Install metering equipment capable of measuring the total energy delivered to ICT systems, including PDUs. This may also include other power feeds where non-UPS protected power is delivered to the racks. Note that this should be required for an energy efficiency meter indicator. |
+| 12.1.3 | Room level metering of supply air temperature and humidity | Install metering equipment at room level, capable of indicating the supply air temperature and humidity for the ICT equipment. |
+| 12.1.4 | CRAC/AHU unit level metering of supply or return air temperature and humidity | Collect data from CRAC/AHU units on supply or return (dependent upon operating mode) air temperature and humidity. |
+| 12.1.5 | PDU level metering of ICT energy consumption | Improve visibility of ICT energy consumption by metering at the PDU inputs or outputs. |
+| 12.1.6 | PDU level metering of mechanical and electrical energy consumption | Improve visibility of data centre infrastructure overheads. |
+
+| No. | Name | Description |
+|--------|-------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.1.7 | Row or rack level metering of temperature | Improve visibility of air supply temperature. |
+| 12.1.8 | ICT device level metering of temperature | Improve granularity by using built-in device level metering of intake and/or exhaust air temperature as well as key internal component temperatures. |
+| 12.1.9 | ICT Device level metering of energy consumption | Improve granularity and reduce metering cost by using built in ICT device level metering of energy consumption. |
+
+## 12.2 Energy use and environmental collection and logging
+
+| No. | Name | Description |
+|--------|----------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.2.1 | Periodic manual readings | Entry-level energy, temperature and humidity reporting can be performed with periodic manual readings of consumption meters, thermometers and hygrometers. This should occur at regular times, ideally at peak load. |
+| 12.2.2 | Automated daily readings | Automated daily readings enable more effective management of energy use. Supersedes periodic manual readings. |
+| 12.2.3 | Automated hourly readings | Automated hourly readings enable effective assessment of how ICT energy use varies with ICT workload. Supersedes periodic manual readings and automated daily readings. |
+| 12.2.4 | Reading of economized cooling hours – new build DC | Require collection and logging of full economizer, partial economizer and full mechanical hours throughout the year. The intent being to record the amount or time and energy spent running mechanical cooling versus relying of free cooling. The site design, cooling system operational set-point and ICT equipment environmental control ranges should allow the data centre to operate without refrigeration for a significant part of the year with no refrigeration for the ICT cooling load as evaluated against a typical meteorological year for the site. Note that this refers to mechanical compress or sand heat pumps, any device which uses energy to raise the temperature of the rejected heat. |
+
+## 12.3 Energy use and environmental reporting
+
+Energy use and environmental (temperature and humidity) data need to be reported to be of use in managing the energy efficiency of the facility.
+
+| No. | Name | Description |
+|--------|--------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.3.1 | Written report | Entry-level reporting consists of periodic written reports on energy consumption and environmental ranges. This should include determining the averaged PUE over the reporting period. |
+| 12.3.2 | Energy and environmental reporting console | An automated energy and environmental reporting console to allow M&E staff to monitor the energy use and efficiency of the facility provides enhanced capability. Averaged and instantaneous PUE are reported. Supersedes written report. |
+
+| No. | Name | Description |
+|--------|-----------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.3.3 | Integrated ICT energy and environmental reporting console | An integrated energy and environmental reporting capability in the main ICT reporting console allows integrated management of energy use and comparison of ICT workload with energy use. Averaged, instantaneous and working range PUE are reported and related to ICT workload. Supersedes written report (best practice 12.3.1) and energy and environmental reporting console (best practice 12.3.2). This reporting may be enhanced by the integration of effective physical and logical asset and configuration data. |
+| 12.3.4 | Reporting of economized cooling hours – new build DC | Require reporting to log full economizer, partial economizer and full mechanical hours throughout the year. The intent being to record the amount of time and energy spent running mechanical cooling versus relying of free cooling. The site design, cooling system operational set-point and ICT equipment environmental control ranges should allow the data centre to operate without refrigeration for a significant part of the year with no refrigeration for the ICT cooling load as evaluated against a typical meteorological year for the site. Note that this refers to mechanical compress or sand heat pumps, any device which uses energy to raise the temperature of the rejected heat. |
+
+## 12.4 ICT reporting
+
+Utilization of the ICT equipment is a key factor in optimizing the energy efficiency of the data centre.
+
+| No. | Name | Description |
+|--------|---------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 12.4.1 | Server utilization | Reporting of the servers' processor utilization globally or grouped by service/location. Whilst effective metrics and reporting mechanisms are still under development, a basic level of reporting can be highly informative. |
+| 12.4.2 | Network utilization | Reporting of the network utilization globally or grouped by service/location. Whilst effective metrics and reporting mechanisms are still under development, a basic level of reporting can be highly informative. |
+| 12.4.3 | Storage utilization | Reporting of the storage utilization globally or grouped by service/location. Whilst effective metrics and reporting mechanisms are still under development, a basic level of reporting can be highly informative. The meaning of utilization can vary depending on what is considered available capacity (e.g., ports, raw versus usable data storage) and what is considered used (e.g., allocation versus active usage). Ensure the definition used in these reports is clear and consistent. Note that mixed incentives are possible here through the use of technologies such as de-duplication. |
+
+# 13 Design of network
+
+This clause contains requirements on network design to connect equipment present in the data centre and the data centre with other data centres.
+
+| No. | Name | Description |
+|------|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 13.1 | Equipment selection | Select network equipment (switches, routers, firewalls, etc.) with best energy efficiency. |
+| 13.2 | Network design | Consider the network design (topology, DC interconnection map and constituent network devices) to maximize egress bandwidth (effective cumulative throughput towards connected DC elements or external networks) relative to energy footprint. Minimize the number of "internal" network elements and interconnects ("grey ports") that are not delivering traffic towards data processing and storage equipment or external networks. |
+| 13.3 | Plan for run-time energy consumption profiling of the network | Consider installing power meters and/or using embedded energy monitoring tools to profile energy utilization within all network devices. In combination with the practices of clause 12, this gives data to assess the efficiency of a network in real-time and plan for extended energy conservation policies. |
+| 13.4 | Establish extended energy conservation policies for network devices | Using information derived from practices outlined in the EU Code of Conduct on Data Centres v4.0.5, consider analysis of productivity patterns and identify opportunities to enable extended energy conservation features within network devices (such as automatic capacity downgrade during certain times of the day). |
+| 13.5 | Use a network as medium to propagate energy conservation policies throughout DC | Consider integration of DC idling and sleep policies (such as best practice 7.4.4) within the network. For instance, implement on-demand reconfiguration of server clusters using "wake-on-LAN" technology. |
+
+# 14 Cloud data centre
+
+The cloud data centre, due to high-density and high integration, requires a more advanced energy-saving approach than the existing data centre from the perspectives of construction, electric power, air conditioning, and other infrastructures. The excessive initial investment cost can be reduced by designing the infrastructure facilities such that phased extension is supported. Moreover, the infrastructure facilities can be operated in an energy-efficient manner by implementing the different availability and power density requirements on a per-module basis.
+
+Therefore, the dedicated cloud data centre should 1) support a high-density environment, 2) house highly energy-efficient equipment to address the problem of high power consumption and high heat emission, and 3) be flexible and scalable to cope with the rapidly changing environment. Lastly, it should have a management system that can control the large-scale ICT resources efficiently and in a cost-effective manner.
+
+## 14.1 High flexibility
+
+The data centre should have flexible scalability to cope with the quick increase of ICT environment resources based on the high-density environment. To implement the data centre in this manner, the space or server room should be implemented with modularized design, unlike traditional centre planning.
+
+| No. | Name | Description |
+|--------|----------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.1.1 | Module composition | The server room modules will consist of the floor module configuration plan (unit of facilities extension) and a plan that can specify the floor module. The detailed plan by phase will be established for the entire space or server room of the data centre considering the facilities area and power usage. |
+| 14.1.2 | Establishment of modularized space or server room plan | The space plan for facilities room modularization will be applied to support the standardized server room module. The minimum unit area will be calculated for expansion through the analysis of the centre's space or server room use plan, which will be configured as the basic module. The space expansion pattern via modularization should consider two patterns: horizontal expansion and vertical expansion. The standardized pattern will be applied to the modularized space or server room so that phased extension can be implemented within a short period of time and according to the business requirements. |
+| 14.1.3 | Applying modularization to the infrastructure space | The infrastructure space plan supporting the modularized space or server room should consist of the common facilities space and modularized facilities space by module. The common facilities space is not affected by the module, e.g., main power receiving and transformation facilities, whereas the modularized facilities space can accommodate the facilities changed by the power requirement of the server room module such as the UPS and battery room, which should be designed as part of the module composition together with the server room. |
+| 14.1.4 | Applying multi-tier that satisfies the availability requirement by module | The infrastructure composition by module will be designed such that it can be differentiated by module according to the availability requirement by individual server room module. Availability by module can be configured with the same or below-tier level with common infrastructure availability and applied differently according to the importance of the system. |
+| 14.1.5 | Flexible configuration of electric power density of the space or server room by module | Independent capacity increase and power density increase will be supported by configuring the individual facilities independently for each module of the modularized data centre. The facilities by module – which should be considered for this -- includes low-voltage substation facilities, mechanical equipment, UPS, battery, PDU, and low voltage cabling, which should be designed according to the requirements of the server to be extended. |
+| 14.1.6 | Applying the common facilities and the modularized facilities by module | The common facilities are configured regardless of module configuration, such as the power substation and power generation facilities. The modularized facilities consist of the UPS, battery, and thermo-hygrostat. The facilities will be designed such way that facilities by module can be configured flexibly based on the common facilities. |
+| 14.1.7 | Implementation of container-type modular data centre | As one of the actual implementation methods of the modularized data centre, the container-type data centre integrates various ICT infrastructures in a cargo container. When this type of centre is introduced, 5~30 k-level, high-density servers can guarantee higher energy efficiency than the existing centre by overcoming the limitation of the place and infrastructure and utilizing effective cooling in airtight rooms. This type also allows flexible extension, since the container park-type, large-size centre can be built by piling up container centres. |
+
+| No. | Name | Description |
+|--------|---------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.1.8 | Implementation of the building-type modular data centre | One of the modular centres, the building-type modular centre, constructs individual server rooms in the centre on a scale of 300~1 200 m 2 . Compared with the container centre, there are limitations in terms of the place and construction period. Note, however, that it is more flexible than other centre construction methods; implementing the high-density, high-integrity centre is also easy, which makes it suitable for the cloud centre. |
+
+## 14.2 High-density data centre
+
+There is an essential need for the proper control and management of high density, high heat generating data centres. Cloud data centres are likely to have a high concentration of systems on each rack resulting in increased and concentrated power dissipation.
+
+While a conventional data centre has 2~4 kW power density per rack, a cloud data centre has to maintain power density of 8~10 kW or higher; hence the need for a different power distribution and cooling system architecture from that of conventional data centres.
+
+Appropriate partitioning and capacity setting are particularly needed to provide agility and easy provisioning (as the features of a cloud service) to build more facilities alongside the expansion of ICT systems. The investment cost and operating cost can be reduced only through such phased expansion and operation.
+
+| No. | Name | Description |
+|--------|---------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.2.1 | Application of high-efficiency solution based on ICT rack standardization | Cold aisle or hot aisle containment should be included in the standardized ICT rack to block heat recycling at the roof; high-density cooling system should be applied for cooling efficiency. Use the standard rack-type high-density PDU to supply appropriately the high power required by the high-density ICT systems. A 3-phase power strip to supply 15 A or higher per phase power should be installed on each rack. |
+| 14.2.2 | Application of high-density cooling system based on chilled water | Use the high-density cooling system based on chilled water to cool the high heat-emission rack system. The cooling system is made up of chiller, computer room air handler (CRAH), in-line or overhead cooling system, etc., and combined with a containment system to maximize performance. For high-density systems with around 30 kW per rack, use a closed cooling system so that the heat is not discharged to the data centre. |
+| 14.2.3 | Application of power solution to provide high energy density | Use a power solution suitable under the high-density environment to provide high energy density in a small installation space. UPS should be a modular type and voltage and frequency independent (VFI) type [ISO/IEC 62040-3] based on insulated-gate bipolar transistor (IGBT) structure. It should be online hot-swappable equipment so that its capacity can be easily expanded. Use Li-ion batteries or Li-ion polymer batteries with smaller installation space and weight to overcome the spatial limitation and operation temperature limitation of the building at the same time. |
+| 14.2.4 | Delivery of scalability through modularization of common infrastructure | For scalability, common infrastructure should be partitioned into smaller units so that the data centre modules can be easily expanded. Use two-step transformation method and install low-voltage transformers near each module to reduce the noise and power transmission loss. Use an integrated free cooling chiller to enable phased expansion and energy saving through free cooling at the same time. The overall piping system should be simplified to save space. |
+
+| No. | Name | Description |
+|--------|----------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.2.5 | Maintenance of high availability ICT system availability in high heat-generating environment | The response time to a cooling system problem becomes more critical as heat generation per rack increases. To deal with the root cause of the problem, supply UPS power to the cooling system or CRAH. In the case of CRAH and cooling tower, install a system to enable redundancy of the power source such as an automatic transfer switch (ATS). Use a thermal storage tank to supply chilled water for 4 to 15 minutes (depending on cooling or electrical technical solution) and maintain operability until the cooling system is restored after it is shut down. |
+| 14.2.6 | Energy-efficient cooling system architecture | Seal the data centre and concentrate on sensible heat cooling to minimize external factors and maintain suitable temperature. Essentially the role of cooling system is control the temperature and humidity to protect from overheat and electrostatic disturbance. The trend of data centre cooling system is increasing the chilled water temperature from a range of 7°C to 12°C to a range of 15°C to 20°C, or more high temperature, to prevent the condensation to achieve more energy saving based on sensible heat cooling structure. This trend is more helpful to increase the free-cooling efficiency. Free cooling using water side economizer or air side economizer will save the electric energy for cooling system greatly from longer free cooling period minimum 70% of the time per year in middle latitude area as some case study. |
+
+## 14.3 Management optimization
+
+Since a cloud data centre has a system environment that is different from that of the conventional data centre, its management should consider the cloud systems. A cloud system under a virtualized environment can often perform logical formations and changes of many servers; hence the need to manage the resource availability data and utilization status data accurately.
+
+Moreover, new measures for network cable configuration and management are needed to support frequent changes of the system architecture. The data centre equipment also needs to be changed considering the nature of cloud systems.
+
+| No. | Name | Description |
+|--------|----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.3.1 | Comprehensive inventory tracking | Since a cloud system logically organizes multiple Windows servers using clustering technology, it should properly manage the configuration data related to the physical system. It also needs an asset management system supporting the system architecture and utilization since it can save on equipment cost (power and heating ventilation and air conditioning (HVAC)) only when it increases the utilization of the resources and restrains power usage by idle resources. |
+| 14.3.2 | Unified networking | Most data centres separately use data network cable and storage area network cable. Note, however, that unifying the data and storage area networks using 10-gigabit Ethernet cable will not only save on cable cost but also reduce the HVAC cost by simplifying the data centre infrastructure architecture and complex cable configuration. It also has the additional benefit of reducing cable consumption and decreasing resource wastage. |
+
+| No. | Name | Description |
+|--------|--------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 14.3.3 | Intelligent cable management System | Since the cloud environment makes the system architecture more complex, effective measures for managing the network cables are needed. A cable management system (CMS), an intelligent network management system, can effectively manage the network cables (by monitoring the cable operation status in real time and remotely controlling the port data with the software in case of a problem) and manage the task history. |
+| 14.3.4 | Dynamic smart cooling | One of the features of a cloud-based data centre is that the allocation and reclaiming of resources occur frequently. Since power consumption and heat generation by the server increase when resources are allocated more often, the system should also control HVAC operation to maintain constant temperature at the same time to reduce the waste of HVAC. In other words, measures for linking infrastructure operation with resource utilization are needed. |
+| 14.3.5 | Consolidated IT and facilities monitoring system | Unlike before, in a cloud-based data centre, the equipment is operated according to the system architecture. Therefore, the system administrator and infrastructure manager should cooperate more closely to exchange information. Until now, system and equipment events were not integrated but managed separately with no data exchange. Addressing such problems requires a system for integrating the system and infrastructure events. |
+
+# 15 Optimization of energy management of whole data centre
+
+In order to reduce energy consumption of the whole data centres, not only energy efficiency for each device such as ICT devices and air-conditioning equipment but also energy optimization for all devices is important.
+
+## 15.1 Optimization of energy management by an integrated control of ICT devices and facility
+
+The power consumption of ICT devices and facility, especially air-conditioning equipment, occupies the most part of total energy of a data centre. To optimize the energy management of the whole data centre, it is efficient to conduct the integrated control of both elements.
+
+| No. | Name | Description |
+|--------|---------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 15.1.1 | Integrated control and management of ICT devices and facility | It is more efficient to link ICT devices and facility and to control both elements optimally on the basis of these operating states in order to improve an energy efficiency of a whole data centre. A proposal of the integrated control is present in the Annex. |
+| 15.1.2 | Total optimization by using energy consumption characteristic of each device constituting a data centre | Each device has an energy consumption characteristic influenced by external conditions, such as operating states of ICT devices and facility, and measurement data from sensors. It is better to grasp the characteristic of all devices and set the control parameters of these devices to minimize total energy consumption. Furthermore, it is capable of more optimization to consider a layout of server room and a characteristic of data centre equipment. |
+
+# Annex A
+
+## Possible methodology for cooling data centres by using renewable energy in cold regions
+
+(This annex forms an integral part of this Recommendation.)
+
+## A.1 Data centres in cold regions
+
+### A.1.1 Conditions of data centre location
+
+The location of a data centre should be selected with various factors in mind, including security from external forces such as earthquakes and floods, availability of a communication infrastructure, stable supply of electric power, convenience of transportation, and recruitment of people to work in the data centre. From the viewpoint of energy efficiency, it is also important to examine whether renewable energy can be used or not.
+
+### A.1.2 Use of renewable energy in cold regions
+
+Renewable energy may be used in various ways, for example, in the generation of electric power and as a heat source. In cold weather regions, efficient cooling becomes possible by using low air temperature, or accumulated snow, as a cold heat source of air conditioning systems at data centres.
+
+## A.2 General matters relating to data centre cooling
+
+### A.2.1 Air conditioning systems for data centres
+
+At data centres, floor-diffused air conditioning systems with raised floors are generally adopted. Figure A.1 shows an example of air conditioning system components. Cool supply air emitted from the air conditioner is heated by a server in the server room, and the heated return air (RA) is returned to the air conditioner. The cycle is repeated. Equipment, such as chillers and water-cooling towers, are required for producing cooling water using electric power, and cooling coils and fans for producing cool air using cooling water. The cooling operation takes place throughout the year at data centres because servers generate a large amount of heat.
+
+
+
+a: Water cooling tower
+b: Chiller
+c: Air handling unit
+d: Cooling coil
+e: Fan
+f: Server rack
+
+L.1300(11)\_FA.1
+
+Diagram of an air conditioning system at a data centre. It shows a cycle where cooling water from a tower (a) and chiller (b) is used in a cooling coil (d) within an air handling unit (c). A fan (e) draws air from a server rack (f), passes it over the cooling coil, and then supplies it as supply air (SA) to the server rack. The server rack heats the air, which becomes return air (RA) and is sent back to the air handling unit. The diagram is labeled L.1300(11)\_FA.1.
+
+Figure A.1 – Air conditioning system components at a data centre
+
+## A.3 Outdoor air cooling
+
+Data centres that require cooling throughout the year could use low-temperature outdoor air in winter for cooling.
+
+#### A.3.1 Outdoor air cooling systems
+
+The modes of cooling systems using the cold heat of low temperature outdoor air are classified into the following categories:
+
+##### (1) Direct use of cold heat
+
+Low temperature outdoor air is taken directly into the server room for cooling. It is taken into the air conditioner and mixed with high temperature return air from the server room, or is directly taken into the server room.
+
+##### (2) Indirect use of cold heat
+
+Cold heat of low temperature outdoor air is used indirectly by performing heat exchange.
+
+##### (3) Selection of the mode of use
+
+In the mode of direct use, cold heat of outdoor air is directly used and high thermal efficiency is achieved. The mode of indirect use is applicable even in cases where no outdoor air can be taken directly because of conditions such as the quality of outdoor air, temperature and humidity. When planning a data centre, various conditions should be comparatively examined and an optimum mode should be selected. Both modes may be used interchangeably in different periods as outdoor air conditions vary.
+
+#### A.3.2 Mechanism of outdoor air cooling and considerations
+
+##### A.3.2.1 Mechanism of outdoor air cooling and temperature and humidity control
+
+At data centres, conditions for supplying air to servers are held in a designated range, so air supply conditions should be held at a certain level when adopting the outdoor air direct use mode.
+
+###### (1) Temperature control methods
+
+Low temperature outdoor air (OA) is taken into the air conditioner and mixed with return air (RA) from the server room. The temperature of supply air (SA) can be kept constant by adjusting the outdoor air/return air mix proportions according to the variation of outdoor air temperature. Unnecessary exhaust heat from the server is discharged outdoors as exhaust air (EA) (Figure A.2).
+
+##### (2) Humidity control methods
+
+In cases where outdoor air is dry, as in winter, humidity should be controlled through humidification. Humidification is achieved by various methods, such as supplying steam, atomizing and vaporizing. Using humidifiers of the drip infiltration vaporization type enables humidification without using any electric power (Figure A.3).
+
+
+
+OA RA EA
+
+a: Air handling unit
+b: Humidifier
+c: Fan
+d: Server rack
+
+SA
+
+L.1300(11)\_FA.2
+
+Diagram of the direct use of outdoor air for cooling in a data center. The diagram shows a cross-section of a room with components labeled: 'a' (Air handling unit), 'b' (Humidifier), 'c' (Fan), and 'd' (Server rack). Air flow is indicated by arrows: Outdoor Air (OA) enters from the top left, mixes with Return Air (RA) from the server rack, passes through the Air handling unit (a) which contains a Humidifier (b) and a Fan (c), and then becomes Supply Air (SA) entering the server rack (d) from the bottom. Exhaust Air (EA) is shown exiting from the top right. The diagram is labeled L.1300(11)\_FA.2 at the bottom.
+
+Figure A.2 – Direct use of outdoor air for cooling
+
+
+
+a: Humidifier b: Waste water pan
+
+Diagram of a drip infiltration vaporization type humidifier. Dry air enters from the left and passes through a vertical column (a: Humidifier) where supply water is introduced. The air exits as humidified air. A waste water pan (b) is located at the base of the column to collect excess water.
+
+**Figure A.3 – Humidifier of drip infiltration vaporization type**
+
+#### A.3.2.2 Cooling cycles and system installation conditions
+
+Changes in air condition during outdoor air cooling, and the ranges of air conditions in which outdoor air cooling can be done, are shown on a psychometric chart (Figure A.4).
+
+![Psychometric chart showing the range of air conditions for outdoor air cooling. The x-axis is Dry-bulb temperature [°C] from -10 to 30. The y-axis is Absolute humidity [kg/kgDA] from 0.000 to 0.016. The chart includes wet-bulb temperature lines, relative humidity lines (10% to 80%), and a dashed green box indicating the 'Range of air conditions that outdoor air cooling can be used'. Points a (OA), b (RA), c (Mixed air), and d (SA) are marked on the chart.](ebd9fdefdb8b316d7bc166aa3ed924a3_img.jpg)
+
+Psychometric chart showing the range of air conditions for outdoor air cooling. The x-axis is Dry-bulb temperature [°C] from -10 to 30. The y-axis is Absolute humidity [kg/kgDA] from 0.000 to 0.016. The chart includes wet-bulb temperature lines, relative humidity lines (10% to 80%), and a dashed green box indicating the 'Range of air conditions that outdoor air cooling can be used'. Points a (OA), b (RA), c (Mixed air), and d (SA) are marked on the chart.
+
+**Figure A.4 – Changes in air condition during outdoor air cooling**
+
+Outdoor air (OA ,point a) and return air (RA, point b) are mixed to create the state of mixed air (point c). Humidity is evaporated by the humidifier and the mixed air is cooled or humidified to create the state of server supply air (SA, point d). The temperature and humidity of outdoor air vary according to the season or time. An appropriate air condition can, however, be created through the adjustment of mix proportions and humidification. If the temperature and humidity of outdoor air meet certain requirements, outdoor air cooling becomes possible. For example, if temperature, relative humidity and absolute humidity are assumed to be 18°C, 65% and 0.0085 kg/kgDA respectively, as water supply conditions of the air conditioner, the range in which outdoor air cooling can be done is represented by the following parameters:
+
+- (1) Outdoor air temperature < 20°C (Note)
+- (2) Absolute humidity < Supply air humidity (0.0085 kg/kgDA)
+- (3) Wet bulb temperature < Wet bulb temperature of supply air (14°C)
+
+NOTE – Determined by the capacity of the humidifier.
+
+Even in cases where the outdoor air condition does not meet the above requirements, cooling by using an electric heat source to compensate for the lack of cold heat enables the reduction of electric power consumption. The range in which outdoor air cooling (combined use) can be done, then expands.
+
+#### **A.3.2.3 Other considerations**
+
+###### **(1) Removal of impurities**
+
+In areas where impure substances are mixed with the air, such as in coastal and volcanic areas, air purity should be kept at a certain level using filters and other equipment.
+
+##### **(2) Compatibility between construction and equipment planning**
+
+At data centres, a large amount of heat is generated and a large amount of cool air is required. Full consideration should, therefore, be made of construction planning such as creating openings on exterior walls of the building that are sufficiently large to take in outdoor air.
+
+### **A.4 Snow and ice cooling**
+
+In regions of heavy snowfall, high costs are incurred for ploughing, storing and melting snow in built-up areas and on arterial highways. However, in such regions, snow may be a source of renewable energy if, instead of being discarded as useless, it is stored in winter and used in summer, when no outdoor air cooling is possible, to cool data centres.
+
+#### **A.4.1 Snow and ice cooling systems**
+
+The cooling and snow storage methods of snow and ice cooling systems are classified into the following categories:
+
+##### **(1) Cooling methods**
+
+Use of air: air is chilled by means of direct contact between air and snow. The method is suitable in cases where a relatively small amount of air is handled. High power is required for conveying the heat, because gas is used as the heating medium.
+
+Use of snowmelt water by performing heat exchange: the cold heat of snowmelt water is used by performing heat exchange. Heat can be conveyed easily, even over a long distance between the snow storage pit and the place to be cooled, because liquid is used as the heating medium.
+
+##### **(2) Snow storage methods**
+
+Indoor storage: a building is constructed exclusively for storing snow, or a part of an existing building (e.g., basement) is used as a snow storage facility.
+
+Outdoor storage: a snow pile is constructed outdoors and the equipment and piping required for obtaining cold heat are installed.
+
+##### **(3) Selection of an appropriate method**
+
+At data centres, servers generate a large amount of heat and, therefore, a large amount of heat is also required for cooling. Using snowmelt water by performing heat exchange is considered more beneficial in view of the efficiency of heat exchange and the ease of heat conveyance. Outdoor storage that requires no building is more appropriate because a large snow pile needs to be constructed.
+
+#### **A.4.2 Mechanism of snow and ice cooling and considerations**
+
+##### **A.4.2.1 Mechanism of snow and ice cooling**
+
+Snowmelt water obtained from snow and ice produces water for cooling via a heat exchanger. Warm water produced by the heat exchanger returns to the snow pile as circulating water and is used again for melting snow and ice (Figure A.5).
+
+
+
+Figure A.5: Systems for circulating snowmelt water and storing snow outdoors. The diagram shows a snow mound (g) where snow melt water is collected. This water is pumped through a chilled water tank grit chamber (h) and then through a heat exchanger (i). The cooled water is then sent to a chiller (b) and a water cooling tower (a). The chilled water is then circulated through an air handling unit (c) containing a cooling coil (d) and a fan (e). The air handling unit is connected to a server rack (f) via return air (RA) and supply air (SA) ducts. The return water from the server rack is sent back to the snow mound. A legend on the right lists the components: a: Water cooling tower, b: Chiller, c: Air handling unit, d: Cooling coil, e: Fan, f: Server rack, g: Snow storage facility, h: Chilled water tank grit chamber, i: Heat exchanger. The diagram is labeled L.1300(11)\_FA.5.
+
+**Figure A.5 – Systems for circulating snowmelt water and storing snow outdoors**
+
+##### A.4.2.2 Operation and management of snow and ice cooling systems
+
+###### (1) Supplying snow and ice
+
+Snow and ice cooling requires the collection of snow and ice that provide the amount of heat required for cooling data centres. Acquiring the cooperation of a local autonomous body, or other organization that manages snow removal in the vicinity, may reduce the running costs during the collection, transport and storage of snow. Securing a large space for snow storage facilities adjacent to the site of a data centre is also necessary.
+
+##### (2) Securing necessary cold heat
+
+As the snow melts, voids are formed between the snowmelt water and snow pile. If the voids become larger, the area of contact between the snowmelt water and snow pile is reduced and the amount of heat obtained is also reduced. If the voids become even larger, the snow pile collapses and the contact between the snowmelt water and snow pile is restored. In the cycle, the temperature of snowmelt water obtained from snow and ice varies. The amount of cold heat can, however, be kept at a certain level by adjusting the flow of cooling water sent to the air conditioner via a heat exchanger.
+
+###### (3) Managing snow storage facilities
+
+The snow collected on the streets contains mud and various types of impurities. Impurities should be removed completely via mud pits or filters. Applying heat-insulating sheeting for storing snow and ice until summer, reduces natural thawing in outdoor snow storage facilities and enables efficient use of snow and ice. Regularly removing deposited impurities, and properly managing the level of snowmelt water, enable stable cooling.
+
+## A.5 Method of cooling data centres in cold regions
+
+### A.5.1 Cooling facilities for data centres in cold regions
+
+At data centres, stable operation is required around the clock, all year round. It is therefore preferable for data centres in cold regions to be equipped with hybrid cooling facilities that make the best use of renewable energy and also use an electric heating source as a backup (Figure A.6).
+
+
+
+Figure A.6: Equipment with hybrid cooling facilities. This diagram is similar to Figure A.5 but includes additional components for hybrid cooling. It shows a snow mound (g) with snow melt water being pumped through a chilled water tank grit chamber (h) and a heat exchanger (i). The water then goes to a chiller (b) and a water cooling tower (a). The chilled water is circulated through an air handling unit (c) which contains a cooling coil (d), a fan (e), and a humidifier (f). The air handling unit is connected to a server rack (g) via return air (RA) and supply air (SA) ducts. The diagram also shows outdoor air (OA) entering the air handling unit and exhaust air (EA) leaving it. The return water from the server rack is sent back to the snow mound. A legend on the right lists the components: a: Water cooling tower, b: Chiller, c: Air handling unit, d: Cooling coil, e: Humidifier, f: Fan, g: Server rack, h: Snow storage facility, i: Chilled water tank grit chamber, j: Heat exchanger. The diagram is labeled L.1300(11)\_FA.6.
+
+**Figure A.6 – Equipment with hybrid cooling facilities**
+
+#### **A.5.2 Energy efficiency and optimum operation control for respective cooling systems**
+
+Outdoor air cooling: cooling can be done only by fan drive power without using any electric heating source. Energy consumption can be greatly reduced.
+
+Snow and ice cooling: electric power is used by pumps for circulating snowmelt water, but no electric cold heat source is used. Electric energy consumption can therefore be reduced.
+
+For cooling, outdoor air, snow and ice and electric heat source cooling systems, are available in the descending order of energy efficiency for cooling. In cold regions, cooling systems can be operated most efficiently by making the best use of outdoor air cooling, and adopting snow and ice cooling, or electric heat source cooling, during the period in which no outdoor air cooling is possible.
+
+### **A.5.3 Maximization of data centre cooling efficiency**
+
+In cold regions, using outdoor air or snow and ice for cooling data centres makes contributions to the reduction of power consumption. Cooling efficiency can be maximized by using outdoor air or snow and ice, in combination with solar radiation, wind power and other types of renewable energy, or with other methods for increasing cooling efficiency.
+
+# Annex B
+
+## Possible methodology for cooling data centres with high-density ICT devices
+
+(This annex forms an integral part of this Recommendation.)
+
+## B.1 Outline of air conditioning methods
+
+#### B.1.1 Conventional air conditioning
+
+##### B.1.1.1 Air conditioning system outline
+
+Figure B.1 shows the conventional air conditioning system in a data centre. Floor supply air conditioning in which multiple floor supply air conditioners (e.g., CRAC) are installed in the room. A large number of server devices are installed on the raised floor in the room, and arranged in a regular pattern, alternately facing the cold aisle (towards which the server device air inlets are directed) and the hot aisle (towards which the exhausts are directed).
+
+Hot interior air, discharged from the hot aisle into the interior upper airspace, is drawn from the top of the floor supply air conditioning equipment, dehumidified and cooled to the specified temperature with chilled water inside the air conditioning equipment, and supplied to an under-floor chamber. This cold air is supplied to the cold aisle from outlets (gratings) in the cold aisle on the raised floor and, after passing through and removing the heat generated by the server devices, it is discharged to the hot aisle as high-temperature exhaust air.
+
+
+
+The diagram illustrates a conventional air conditioning system for a data centre. At the top, a 'Chiller' unit is connected to a 'Cooling tower' via a 'Cooling water pump'. A 'Chilled water pump' is also shown, connected to the chiller. Below this, a 'Floor supply type air conditioner' (CRAC) is depicted. The CRAC unit is connected to the chilled water lines and has an air intake from the 'Hot aisle' (indicated by an orange arrow) and an air outlet into the 'Cold aisle' (indicated by a blue arrow). The 'Cold aisle' and 'Hot aisle' are shown as alternating zones between rows of 'Server' units. Blue arrows represent cold air flow from the cold aisle, through the server inlets, and into the hot aisle. Orange arrows represent hot air flow from the server exhausts into the hot aisle and then being drawn up into the CRAC unit. The diagram is labeled 'L.1300(11)\_FB.1' at the bottom right.
+
+Diagram of a conventional air conditioning system in a data centre.
+
+Figure B.1 – Conventional air conditioning system
+
+##### B.1.1.2 Control system and operating status
+
+With the floor supply conventional air conditioning system, the amount of chilled water passed through the cooling coils is controlled to maintain the air supplied to the room at a constant temperature. With this method, the cooled air is supplied from the outlets on the floor, mixed with the air in the room, and drawn into the server devices. In the typical server room, allowable server inlet air temperature is around 25°C, and supply air temperature necessary to keep the server inlet temperature lower than allowable temperature is generally approximately 18°C. Humidity is adjusted by dehumidifying with the cooling coils and by evaporative humidification.
+
+##### B.1.1.3 Problems
+
+Figure B.2 shows the problems associated with the conventional air conditioning system. This cold air is introduced from the server inlet side facing onto the cold aisle and, after cooling the devices, it is discharged from the rear side of the rack as hot air. If part of the high-temperature exhaust air is circulated into the inlet side, a hot spot occurs in which the temperature at the server rack inlet increases, with the associated risk of performance deterioration of the ICT devices and other damage due to high temperatures, and the ultimate danger of a halt to service.
+
+Since low-temperature air is supplied from the under-floor chamber to the entire room with a conventional air conditioning system, the proportion of electric power required to distribute the large volume of air is considerable because of excessive operation of the air conditioning equipment to prevent hot spots happening. This may result in reduced efficiency of the air conditioning operation, and a consequent increase in air conditioning power consumption.
+
+
+
+Diagram illustrating the problems with typical air conditioning in a server room. A floor supply type air conditioner is shown on the left, supplying a large volume of air to the entire server room. The air is distributed through a raised floor (under-floor chamber) to server racks containing ICT devices. The air is discharged from the rear side of the racks as hot air. A hot spot is indicated by a red cloud above the server racks, caused by the circulation of high-temperature exhaust air into the inlet side. This leads to a temperature increase at the server rack inlet, which can cause performance deterioration and damage. The diagram also shows a distribution board on the right. Labels include: 'Temperature increase due to exhaust air circulation', 'Hot spot', 'Floor supply type air conditioner', 'Server rack', 'ICT device', 'Distribution board', 'Under-floor chamber', 'Large air volume is supplied to the entire server room', and 'Increased power consumption'. The diagram is labeled L.1300(11)\_FB.2.
+
+Figure B.2 – Problems with typical air conditioning
+
+### B.1.2 Outdoor air cooling system
+
+#### B.1.2.1 Air conditioning system outline
+
+Figure B.3 shows the configuration of the outdoor air cooling system. With outdoor cooling, in addition to floor-supply air conditioners supplying cooled air to the room as with conventional air conditioning, the air conditioning system incorporates exhaust fans discharging air from the room to the outside, and outdoor air ducting introducing outdoor air to the air conditioners.
+
+A large number of server devices are installed in server racks on the raised floor in the room, arranged in a regular pattern alternately facing the cold aisle (towards which the server device air inlets are directed) and the hot aisle (towards which the exhausts are directed).
+
+With this method, as with conventional air conditioning, air cooled with multiple floor supply air conditioners (e.g., CRAC) installed in the room is supplied to the room for cooling. During the intermediate seasons, and in winter (during which outdoor air temperature is low), outdoor air is introduced directly to the air conditioner to reduce the amount of cooling required by the cooling coils, and water chilling unit energy consumption for generating chilled water is greatly reduced. Furthermore, the same amount of air is exhausted from the hot aisle as is introduced from outside.
+
+
+
+Figure B.3 – Outline of an outdoor air cooling system. The diagram shows a server room with 'Cold aisle' and 'Hot aisle' sections. Servers are located in the hot aisle. Air is drawn from the hot aisle, passes through a 'Floor supply type air conditioner' (containing sensors for temperature 'T', humidity 'H', and pressure 'dP'), and is then supplied to the cold aisle. The air conditioner is connected to a 'Chiller' via a 'Chilled water pump'. The chiller is connected to a 'Cooling tower' via a 'Cooling water pump'. An 'Exhaust fan' is shown on the left wall. Control units ('Cont.') are connected to the sensors and the air conditioner. The diagram is labeled 'L.1300(11)\_FB.3'.
+
+dP – Deep pressure
+
+H – Humidity
+
+T – Temperature
+
+**Figure B.3 – Outline of an outdoor air cooling system**
+
+##### B.1.2.2 Control system and operating status
+
+Figure B.4 shows the operation control method and trends in the status of the air with outdoor air cooling. During the intermediate period, and winter, low-temperature air (2) is introduced into the air conditioner, mixed (3) with return air (1) in the room, and air cooled and humidified by a cooling coil and an evaporative humidifier and supplied to the room (4). When the temperature of the humidified air is lower than that of the supplied air, an electric heater is used to heat the air to the specified temperature (5) to prevent condensation.
+
+Large amounts of ICT equipment are commonly installed in the room, and temperature and humidity are strictly controlled to prevent faults in, and deterioration of, equipment. With this method, the amount of outdoor air introduced is controlled to ensure that the low-temperature air supplied to the room is of the specified humidity. Furthermore, to ensure that the supplied air reaches the specified temperature, an electric heater is employed as necessary to heat the air before being supplied to the air conditioner. When temperature and humidity conditions are such that energy conservation through the introduction of outdoor air is not possible, the outdoor air intake duct is closed according to the measured outdoor air enthalpy value, and operation is the same as for conventional air conditioning. Furthermore, in order to introduce the large volumes of outdoor air required, the volume of air passed through the exhaust fan is controlled to ensure that air pressure in the room reaches the specified value.
+
+
+
+Psychrometric chart and schematic diagram of an outdoor air evaporative cooling system. The chart plots Absolute humidity (kg/kgDA) from 0 to 0.04 against Temperature (°C) from -10 to 50. It shows saturation curves (0-100%) and constant relative humidity lines (20-80%). A schematic diagram shows the air flow: (1) Return air from the server room, (2) Outdoor air intake, (3) Mixing of return and outdoor air, (4) Cooling coil, (5) Evaporative humidifier, (6) Heater, and (7) Supply air to the server room. The chart shows the state points of the air at each stage: Point 1 (Return air) at approx. 28°C, 0.011 kg/kgDA; Point 2 (Outdoor air) at approx. 10°C, 0.007 kg/kgDA; Point 3 (Mixed air) at approx. 22°C, 0.009 kg/kgDA; Point 4 (After cooling coil) at approx. 18°C, 0.008 kg/kgDA; Point 5 (After evaporative humidifier) at approx. 18°C, 0.010 kg/kgDA; Point 6 (After heater) at approx. 22°C, 0.010 kg/kgDA; Point 7 (Supply air) at approx. 22°C, 0.010 kg/kgDA.
+
+**Figure B.4 – Air status in an outdoor air evaporative cooling system**
+
+##### B.1.2.3 Caution
+
+With outdoor cooling, the status of the outdoor air is measured to determine whether or not outdoor air can be introduced, and control the operation mode. The operation mode changes frequently with changes in the status of the outdoor air, with the possibility of a deterioration in the ability to control the indoor environment. The control system is designed to minimize these frequent changes in the operation mode, and thus achieve stable environmental control. Furthermore, in regions where outdoor air temperature is low, low-temperature air and hot air are mixed and supplied to the room, and a design to prevent temperature irregularities and reduced temperatures is necessary.
+
+With this method, low-temperature external air is introduced directly for cooling, thus reducing heat source power, however blower power is increased by installation of indoor discharge fans and increased ventilation resistance of outdoor air intake ducts. In order to determine the energy conservation within the entire system, it is important to introduce an operation control system able to determine the difference between the reductions in heat source power and blower power.
+
+#### B.1.3 Evaporative cooling system
+
+##### B.1.3.1 Air conditioning system outline
+
+Figure B.5 shows the configuration of the evaporative cooling system. As with a conventional system, evaporative cooling employs floor supply air conditioners to supply cold air to the room. Furthermore, the equipment is made up of an evaporative cooling unit comprising an evaporative cooler to cool return air passed from the room to the air conditioner with outdoor cold air, and an indirect sensible heat exchanger, an outdoor air fan passing outdoor air through the evaporative cooling unit, and a circulation fan passing air through the evaporative cooling unit.
+
+A large number of server devices are installed in server racks on the raised floor in the room, arranged in a regular pattern alternately facing the cold aisle (towards which the server device air inlets are directed) and the hot aisle (towards which the exhausts are directed). The high-temperature interior air discharged from the hot aisle into the space at the top of the room is drawn in from the top of the floor supply air conditioners, dehumidified and cooled to specifications using the cooling coils in the air conditioner, and supplied to the under-floor chamber. Part of the air circulated in the air conditioner from the hot aisle is introduced to the evaporative cooling unit. Similarly, outdoor air is
+
+introduced into the evaporative cooling unit, and outdoor air humidified in the evaporative cooler, and the resulting cooled air and return air exchange heat indirectly so that humidity remains unchanged while the temperature is reduced. Thus, the interior return air cooled with the latent heat of evaporation of water is mixed with interior return air circulated directly in the air conditioner, dehumidified and cooled to the specified temperature using chilled water in the cooling coils in the air conditioner, and supplied to the under-floor chamber.
+
+
+
+Figure B.5 – Outline of an evaporative cooling system. The diagram shows a cross-section of a building with a server room. On the left, an 'Evaporative cooler' and an 'Indirect sensible heat exchanger' are shown. Air from the server room is drawn into the heat exchanger, where it is cooled by air from the evaporative cooler. The cooled air is then mixed with 'Circulation fan' air and sent to a 'Floor supply type air conditioner' under the floor. The server room has 'Cold aisle' and 'Hot aisle' sections with 'Server' racks. A 'Chiller' is connected to a 'Cooling tower' and 'Cooling water pump'. A 'Chilled water pump' is also shown. An 'Exhaust fan' is on the left wall. Arrows indicate air flow: blue for cool air, orange for hot air. Labels include: Chiller, Cooling water pump, Cooling tower, Chilled water pump, Exhaust fan, Circulation fan, Evaporative cooler, Indirect sensible heat exchanger, Floor supply type air conditioner, Server, Cold aisle, Hot aisle, and L.1300(11)\_FB.5.
+
+**Figure B.5 – Outline of an evaporative cooling system**
+
+##### B.1.3.2 Control system and operating status
+
+Figure B.6 shows the trend in the status of the air with this method. With the evaporative cooling method, the intermediate period and winter low-temperature outdoor air (5) is humidified with the evaporative cooler in the evaporative cooling unit, cooled further (6), heat exchanged indirectly with the interior return air (1) in the sensible heat exchanger, and the interior return air cooled (2). The cooled interior return air (2) is mixed (3) with the circulated interior return air, cooled (4) to the required temperature with the cooling coils in the air conditioner, and supplied to the room. Here, depending on the outdoor air conditions, the interior return air shall be dehumidified at the heat exchanger because of the low temperature of outdoor air. In this case, the evaporative humidifier is controlled by following measured outdoor air conditions. Also, under outdoor air conditions of temperature and humidity in which the cooling effect is reduced and energy conservation cannot be expected, the exhaust fan and circulation fan are halted and ducts are switched to prevent the waste of electric power.
+
+
+
+Figure B.6: Air status in an evaporative cooling system. The figure consists of a psychrometric chart and a schematic diagram. The chart plots Absolute humidity (kg/kgDA) from 0 to 0.04 against Temperature (°C) from -10 to 50. It shows state points 1 through 7 and processes for supply and return air. The schematic diagram shows the air flow: Return air (1) from the server room enters the air conditioner, passes through a cooling coil (2), then through an evaporative sensible heat exchanger (3). Outdoor air (5) is drawn in, passes through an evaporative cooler (6), and is mixed with the return air (4) before entering the air conditioner. The supply air (7) is then delivered back to the server room.
+
+**Figure B.6 – Air status in an evaporative cooling system**
+
+##### B.1.3.3 Caution
+
+With the evaporative cooling method, the low-temperature outdoor air is humidified in the evaporative cooler to further cool its temperature. However, under conditions in which the outdoor air wet-bulb temperature is 0°C or lower, water used to humidify the air in the evaporative cooler may freeze. To prevent such freezing, control is implemented to prevent humidification, and air is passed through the equipment, in response to outdoor air conditions. Similarly, in the sensible heat exchanger, when the temperature of the outdoor air is low, it is possible that return air may be dehumidified in the sensible heat exchanger, and a method of control must be implemented to prevent dehumidification.
+
+The evaporative cooling method uses cooling by the outdoor air to reduce the power required by the chilling unit. However, fan power required to pass outdoor air or return air through the evaporative cooling unit is increased. In order to determine the energy conservation within the entire system, it is important to introduce an operation control system able to determine the difference between the reductions in chilling system and distribution power, such as fans etc.
+
+#### B.1.4 Spot cooling with a conventional air conditioning system
+
+#### B.1.4.1 Air conditioning system outline
+
+Figure B.7 shows the configuration of the spot cooling system used for natural circulation of the refrigerant. The combined spot cooling method and typical air conditioning method, and the spot cooling method alone, are possible for cooling. However, a system was configured using only the spot cooling method.
+
+A large number of server racks incorporating server devices are installed on the free access floor in the room, and are arranged alternately facing the cold aisle (towards which the server rack air inlets are directed) and the hot aisle (towards which the exhausts are directed).
+
+With the spot cooling method, a spot cooling unit cooling the air in the hot aisle and circulating it in the cold aisle, and a water-cooled condenser using chilled water to condense refrigerant gas evaporated with the spot cooling units, are installed. Suspended spot cooling units employing natural circulation of refrigerant are installed in the space between the server rack and the ceiling. These units draw in the high-temperature return air discharged from the hot aisle into the space above the room,
+
+cool the return air in the room to the specified temperature by evaporating the refrigerant in the cooling coils in the cooling units, and supply it to the cold aisle. The refrigerant evaporated in the cooling coils is circulated naturally using the liquid gas density difference and circulates through the water-cooled condenser naturally to transport heat to the exterior.
+
+With this method, the spot cooling units cool the air locally, and are thus effective in preventing hot spots. Furthermore, by locally handling the entire amount of heat generated in the room, the blowers supplying large volumes of air to the entire room, as with the typical air conditioning method, are substituted by a small fan for localized air circulation, and a large reduction in heat transport power is possible.
+
+
+
+The diagram illustrates a spot cooling system. At the top, a 'Chiller' is connected to a 'Cooling tower' via a 'Cooling water pump'. A 'Chilled water pump' is connected to the 'Chiller' and a 'Water cooled condenser'. The 'Water cooled condenser' is located above the server racks. Below the condenser, there are two 'Aisle cap' units. Each aisle cap contains a 'Spot cooling unit (hanging type)'. The server racks are labeled 'Server'. The diagram shows air flow: 'Cold aisle' on the left and right, and 'Hot aisle' in the center. Arrows indicate the flow of chilled water and refrigerant. The text 'L.1300(11)\_FB.7' is at the bottom right.
+
+Diagram of a spot cooling system showing the flow of chilled water and refrigerant.
+
+**Figure B.7 – Outline of a spot cooling system**
+
+Figure B.8 shows an outline of the natural refrigerant circulation method. The high-temperature exhaust from the server rack is passed through the cooling coils by a small fan in the spot cooling unit. The refrigerant in the cooling coils absorbs heat from the high-temperature exhaust air and evaporates the refrigerant. The density of the gas is reduced, and it therefore circulates through the water-cooled condenser installed above the coils. In the water-cooled condenser, the refrigerant is condensed to a liquid by the chilled water, and falls under gravity and thus circulates through the cooling coils. This natural circulation of the refrigerant permits heat transport without motive power.
+
+Heat generated in the server rack is transported to the exterior by the air and refrigerant. With this method, the refrigerant is transported without motive power using natural circulation, and the air is circulated locally, so that heat transport is possible with very low blower power. This permits a large reduction in heat transport power in comparison to the typical air conditioning method.
+
+
+
+Diagram illustrating the principle of a refrigerant natural circulation system. A 'Water cooled condenser' is at the top, receiving 'Chilled water (inlet)' and discharging 'Chilled water (outlet)'. Below it, two 'Spot cooling unit (Evaporator)' units are shown. Refrigerant gas (orange dashed line) rises from the evaporators to the condenser, labeled 'Refrigerant gas rises by a small specific gravity'. Refrigerant liquid (blue dashed line) falls from the condenser to the evaporators, labeled 'Refrigerant liquid falls by gravity'. Each evaporator has a 'Cooling coil' and a 'Small fan'. Air from 'Rack exhaust' is drawn into the evaporator and 'Supply air' is discharged. A note states: 'Water cooled condenser must be installed in the upper area of the spot cooling unit'. The diagram is labeled 'L.1300(11)\_FB.8'.
+
+- No power for distribution by refrigerant natural circulation
+- Air transport power saving by spot cooling
+
+**Figure B.8 – Principle of a refrigerant natural circulation system**
+
+##### B.1.4.2 Control system and operating status
+
+With the spot cooling method, the refrigerant evaporated in the cooling units is condensed in the water-cooled condensers, and the flow of chilled water through the water-cooled condensers is controlled to maintain the refrigerant at the specified temperature. Furthermore, the high-temperature air in the hot aisle is drawn in, and the flow of refrigerant controlled to ensure that the cooling unit outlet air reaches the specified temperature.
+
+##### B.1.4.3 Caution
+
+This method involves a system in which multiple spot cooling units are installed at the top of the server racks, and differs from conventional air conditioning supplying chilled air to the room from the floor. Since the cooling unit layout affects the thermal environment, it is important to have an appropriate layout plan for the server rack arrangement and load distribution at the planning stage. The exhaust air from the server racks is introduced efficiently to the cooling units, thus improving the thermal environment, and highly efficient operation with improved cooling performance of the cooling unit is possible. Methods of preventing air dispersion in the hot aisle are therefore effective.
+
+## B.2 Selection of cooling systems suited to data centre specifications
+
+When selecting air conditioning systems for data centres, improved efficiency of ICT equipment, and progress in cloud computing, require high levels of space efficiency to permit the installation of large amounts of ICT equipment in a limited space. Furthermore, from the point of view of preventing global warming and controlling running costs, high levels of energy conservation are required to increase air conditioning energy efficiency, and control energy consumption. The factors and effective air conditioning methods to ensure space efficiency and energy efficiency of the various air conditioning methods were therefore investigated.
+
+### B.2.1 Data centre power density and cooling methods with high space efficiency
+
+Energy conservation is naturally a matter of importance in the construction of urban data centres. However, space efficiency in terms of the maximum number of server racks able to be installed is also important. With conventional air conditioning, outdoor air cooling, and evaporative cooling systems, air conditioning equipment is installed in the room to circulate air heated by the ICT equipment throughout the entire room. With these methods, increased power density of a data centre requires higher cooling performance and larger dimensions to the air conditioning equipment, with
+
+consequently greater floor area required for installation of air conditioning equipment. Here, power density indicates energy consumption of ICT equipment per unit floor area of data centre. On the other hand, with the spot cooling method using natural circulation of the refrigerant, spot cooling units are suspended from the ceiling above the server racks. Use of this space eliminates the need for floor area to accommodate a conventional floor supply air conditioning unit, and ensures that it is possible to accommodate an increased number of cooling units when power density increases, and thus allows a major reduction in the carbon footprint of cooling equipment. Furthermore, with conventional methods, cold air is supplied throughout the floor chamber, and increased floor chamber height is therefore required for cold air supply. With this method, under-floor chambers are not required, and floor height can be reduced.
+
+### **B.2.2 Outdoor air conditions and high energy-efficiency cooling methods**
+
+Energy consumption of air conditioning systems is comprised of power consumed by water chilling units employed in the production of chilled water required to cool air, and power consumed by heat transport equipment such as fans and pumps used to transport heat inside and outside the room.
+
+Outdoor air cooling systems and evaporative cooling systems are able to make effective use of low-temperature outdoor air, and permit a reduction in heat source power. However, the ventilation resistance of evaporative cooling units, air transport ducts, and under-floor chambers is considerable, and blower power is therefore increased. In cold regions, when outdoor air wet-bulb temperature is low, chilling system energy consumption is therefore considerably reduced, ensuring the most energy-efficient air conditioning method.
+
+On the other hand, the spot cooling method employs the natural circulation of the refrigerant, and interior cooling is therefore possible by localized air circulation, so that blower power required for air circulation is greatly reduced in comparison with the typical air conditioning and outdoor air cooling, evaporative cooling methods. Furthermore, the spot cooling method employs the natural circulation of refrigerant, permitting heat transport without motive power, so that heat transport power can be greatly reduced in comparison with the typical air conditioning method. With this method, energy-efficiency is improved through reduced transport power, even outside cold regions, thus ensuring the most energy-efficient air conditioning method in temperate regions.
+
+Based on this comparison, for the construction of data centres with a high power density, located in a temperate region, space efficiency of suspended spot cooling units employing the spot cooling method with natural circulation of refrigerant is highest, air conditioning efficiency is high, and spot cooling is therefore the most appropriate air conditioning method for high-power density data centres.
+
+#### **B.2.3 Further efficiency improvements**
+
+In addition to the large reduction in transport power through use of this spot cooling method, it is also effective to consider the reduction in heat source power (which accounts for a large proportion of cooling system energy), when determining the efficiency of a cooling system. In cold areas, heat source power can be reduced through effective use of low-temperature exterior air to produce chilled water with the free-cool method, and with large, high-efficiency refrigeration units.
+
+Appropriate control of a cooling system for the amount of heat generated is effective in reducing its power consumption. Methods to control the operation of air conditioners in conjunction with the power information for ICT devices, and methods of controlling optimized operation of the entire cooling system while monitoring the energy consumption of the entire system, are effective.
+
+# **Annex C**
+
+## **Practical solutions for correcting airflow direction for equipment**
+
+(This annex forms an integral part of this Recommendation.)
+
+In the case where the airflow can be in different directions for equipment mounted in a rack/cabinet, it is necessary to install a plate or duct to achieve an efficient solution. This annex provides two requirements for this duct/plate installation and design.
+
+## **C.1 Requirements for correcting airflow direction for equipment**
+
+### **C.1.1 Design**
+
+The shape of the plate or duct should be designed so as not to decrease the intake and exhaust capacity of the equipment once it is installed.
+
+### **C.1.2 Description in the installation manual of the equipment**
+
+A description should be added to the installation manual of such equipment so that practical solutions can be easily implemented.
+
+# Annex D
+
+## Minimum data set for controlling data centre equipment for energy saving management in data centres
+
+(This annex forms an integral part of this Recommendation.)
+
+Table D.1 below, lists the minimum data set necessary for evaluating energy efficiency and for controlling data centre equipment in order to save power in data centres. The rationale for this minimum data set is described in [b-ITU-T DC-MDS]. "G" and "S" in the "Data flow direction" column respectively represent data that should be obtained from the equipment and data that should be set according to the equipment.
+
+**Table D.1 – Minimum data set controlling data centre equipment for energy saving management in data centres**
+
+| Type of equipment | | Data set | Data flow direction |
+|--------------------|---------------------------------------|--------------------------------------------------------------------------|---------------------|
+| ICT equipment | | Input power | G |
+| | | Inlet temperature | G |
+| | | Power state (shutdown, sleep, active) | G |
+| | | Power state (shutdown, activate) | S |
+| Facility equipment | Cooling equipment | Input power | G |
+| | | Inlet temperature of indoor unit | G |
+| | | Outside temperature | G |
+| | | On-off state | G/S |
+| | | Amount of refrigerant supplied from an indoor unit to ICT equipment | G/S (1) |
+| | | Temperature of refrigerant supplied from an indoor unit to ICT equipment | G/S (1) |
+| | Power equipment (UPS, rectifier, PDU) | Output power | G |
+| | | Input power | G |
+
+(1) If data cannot be obtained from the equipment, data can be estimated by using alternative data which can be obtained from the equipment and static data of the equipment. An example of estimation is shown in [b-ITU-T DC-MDS].
+
+# **Annex E**
+
+## **Verification experiments related to increase of efficiency of air-conditioning and control technologies at a data centre**
+
+(This annex forms an integral part of this Recommendation.)
+
+## **E.1 Overview**
+
+As ICT devices such as servers are integrated into high-density data centres, energy consumption per unit floor space is high, and large amounts of energy are needed for air-conditioning to cool these devices. The power consumption of ICT devices and the power consumption of air-conditioning equipment are closely related to each other, and to reduce the power consumption in the entire data centre, optimum control of ICT devices and air-conditioning equipment as a linked system is effective. Major reductions of power consumption can be realized by combining ICT load consolidation control, which optimizes ICT device operating states in conjunction with computational load (workload), with ICT linked air-conditioning control, which controls air-conditioning in coordination with the operating state of the ICT devices. In addition, by applying these controls to multiple data centres, total power consumption can be decreased by remote load distribution, which allocates the workload in appropriate ratios.
+
+The basic line of thought of ICT load consolidation control, ICT linked air-conditioning control, and remote load distribution is to build a model that represents power consumption of the whole data centre and to decide control parameters of the model to minimize the total power consumption. Construction of a model related to energy consumption in a data centre is described in clause E.2, a control method that minimizes energy consumption on the basis of the model is described in clause E.3, and a control system that executes minimization of energy consumption is described in clause E.4.
+
+## **E.2 Data centre energy model**
+
+### **E.2.1 Construction of a model of the whole data centre**
+
+Diversified equipment such as servers, network switches, storage devices, air-conditioning equipment, power supply devices and lighting fixtures are used in a data centre and are closely related to each other. By constructing a model of electric power characteristics and energy flow of each one of these devices, it becomes possible to visualize, manage and optimally control the state of energy consumption in the data centre. Figure E.1 shows an example of energy flow in a typical data centre.
+
+Furthermore, the energy consumption in a data centre is also related to external conditions such as workload and open air temperature. Figure E.2 shows typical external conditions.
+
+Image: Figure E.1 – Example of energy flow of data centre
+
+The diagram shows a 'Datacenter' containing various components. Electricity (yellow arrows) flows from a Transformer (Xfmr) to a Power Distribution Unit (PDU). From this PDU, it splits to another PDU, Lighting, and an Outdoor AC unit. The second PDU feeds a Rack. Inside the Rack, power goes to a UPS (Uninterruptible Power Supply), which then distributes it to a Server, Network switch, and Storage. Heat (red arrows) is generated by the Server, Network switch, and Storage, and is collected by an Indoor AC unit, which then transfers it to the Outdoor AC unit. A legend at the bottom defines the symbols: yellow arrow for Electricity, red arrow for Heat, Xfmr for Transformer, PDU for Power distribution unit, UPS for Uninterruptible power supply, and AC for Air conditioning unit. The reference code L.1300(14)\_FE.1 is in the bottom right.
+
+**Figure E.1 – Example of energy flow of data centre**
+
+Image: Figure E.2 – Example of external conditions related to power consumption
+
+This diagram shows a 'Datacenter' containing a 'Server' and an 'Air-conditioner'. A 'Workload' input goes into the Server. 'Set temperature, etc.' and 'External air conditions' are inputs to the Air-conditioner. Both the Server and Air-conditioner contribute to the total 'Power consumption' output. The reference code L.1300(14)\_FE.2 is in the bottom right.
+
+**Figure E.2 – Example of external conditions related to power consumption**
+
+### E.2.2 Construction of a server model
+
+A power consumption model of a server is composed of the cooling fan portion and the system board portion (including CPU, memory, hard disk drive (HDD) and PSU). Other than the cooling fan, the power consumption of each one of these portions depends on the interior server temperature and workload as shown in Figure E.3. The power consumption characteristics of the system board can be estimated from data of the Standard Performance Evaluation Corporation (SPEC). Figure E.4 shows typical power consumption characteristics of a system board. The power consumption of the fan, on the other hand, is determined by the fan speed, which can be estimated from the product specification. The fan speed is controlled by the temperature inside the server and inlet air temperature as shown in Figure E.5.
+
+Image: Figure E.3 – Example of server model
+
+The diagram illustrates a 'Server' model. It has two main internal blocks: 'System board model (CPU, memory, HDD, PSU, etc.)' and 'Fan model'. The 'Workload' input feeds into the System board model. The 'Server inside temperature (inlet air temperature, CPU temperature and memory temperature)' input feeds into both the System board model and the 'Fan control table' within the Fan model. The System board model outputs to 'Power consumption'. Within the Fan model, the 'Fan control table' determines 'Fan speed', which then uses a 'Power table' to contribute to 'Power consumption' and also determines the 'Airflow volume' output. The reference code L.1300(14)\_FE.3 is in the bottom right.
+
+**Figure E.3 – Example of server model**
+
+54 Rec. ITU-T L.1300 (06/2014)
+
+![Figure E.4: Example of power consumption characteristic of system board. A dual-axis line graph showing Power consumption [W] (left y-axis, 0 to 300) and Performance to power ratio (right y-axis, 0 to 1) versus Workload [%] (x-axis, 0 to 100). A solid blue line represents power consumption, and a dashed red line represents the performance to power ratio. The graph is labeled L.1300(14)_FE.4.](a74fdbc8b78564b89bc1b262cfd995b6_img.jpg)
+
+| Workload [%] | Power consumption [W] | Performance to power ratio |
+|--------------|-----------------------|----------------------------|
+| 0 | 0 | 0 |
+| 25 | 100 | 0.4 |
+| 50 | 150 | 0.7 |
+| 75 | 200 | 0.9 |
+| 100 | 250 | 1.0 |
+
+Figure E.4: Example of power consumption characteristic of system board. A dual-axis line graph showing Power consumption [W] (left y-axis, 0 to 300) and Performance to power ratio (right y-axis, 0 to 1) versus Workload [%] (x-axis, 0 to 100). A solid blue line represents power consumption, and a dashed red line represents the performance to power ratio. The graph is labeled L.1300(14)\_FE.4.
+
+(Blue line: Power consumption; Red dotted line: Performance to power ratio (100% workload is expressed as 1))
+
+**Figure E.4 – Example of power consumption characteristic of system board**
+
+![Figure E.5: Example of fan characteristics. Two line graphs. The left graph shows Fan speed [%] (y-axis, 0 to 100) versus Inlet air temperature [°C] (x-axis, 0 to 40). The right graph shows Power consumption [W] (y-axis, 0 to 100) versus Fan speed [%] (x-axis, 40% to 100%). Both graphs show a linear increase. The right graph is labeled L.1300(14)_FE.5.](9c888dd6588358989047de6ced8b2bdb_img.jpg)
+
+| Fan speed [%] | Power consumption [W] |
+|---------------|-----------------------|
+| 40% | 0 |
+| 50% | 10 |
+| 60% | 20 |
+| 70% | 30 |
+| 80% | 40 |
+| 90% | 60 |
+| 100% | 90 |
+
+Figure E.5: Example of fan characteristics. Two line graphs. The left graph shows Fan speed [%] (y-axis, 0 to 100) versus Inlet air temperature [°C] (x-axis, 0 to 40). The right graph shows Power consumption [W] (y-axis, 0 to 100) versus Fan speed [%] (x-axis, 40% to 100%). Both graphs show a linear increase. The right graph is labeled L.1300(14)\_FE.5.
+
+**Figure E.5 – Example of fan characteristics**
+
+(Left: Fan control table; Right: Power table (Maximum fan speed is expressed as 100%))
+
+### E.2.3 Construction of an air-conditioner model
+
+It is considered that the electric energy consumed by ICT devices is entirely converted into heat, and that the heat generated out of ICT devices is entirely cooled with an air-conditioner. For the power consumption of an air-conditioner related to cooling, a model can be constructed as shown in Figure E.6. The power consumption characteristics of an air-conditioner largely vary by the composition and type of the air-conditioner. But typical power consumption characteristics of an air-conditioner outdoor unit that is composed of a fan, heat exchanger and compressor are shown in Figure E.7 as estimated from the product specification.
+
+
+
+```
+
+graph LR
+ subgraph Indoor_unit [Indoor unit]
+ Fan[Fan]
+ HE[Heat exchanger]
+ Valve[Valve]
+ end
+ subgraph Outdoor_unit [Outdoor (heat source) unit]
+ OHU[Outdoor (heat source) unit]
+ end
+ SA[Supply airflow] --> Fan
+ ST[Supply air temperature] --> Valve
+ HL[Heat load] --> Valve
+ EAC[External air conditions] --> Valve
+ Valve --> QH[Quantity of heat]
+ QH --> OHU
+ OHU --> PC[Power consumption]
+ OHU --> HE
+ HE --> Fan
+ Fan --> HE
+
+```
+
+Figure E.6: Example of air-conditioner model. A block diagram showing the flow of air and heat within an indoor unit and its interaction with an outdoor unit. Inputs include Supply airflow, Supply air temperature, Heat load, and External air conditions. The indoor unit contains a Fan, Heat exchanger, and Valve. The outdoor unit is labeled 'Outdoor (heat source) unit'. The final output is Power consumption. The diagram is labeled L.1300(14)\_FE.6.
+
+**Figure E.6 – Example of air-conditioner model**
+
+![Figure E.7: A 3D surface plot showing the relationship between Power consumption [kW], Thermal load [kW], and Supply air temperature [°C]. The vertical axis (Power consumption) ranges from 0 to 30 kW. The horizontal axis (Thermal load) ranges from 0 to 75 kW in increments of 15. The depth axis (Supply air temperature) ranges from -10 to 40 °C in increments of 10. The surface is a mesh grid showing that power consumption increases as both thermal load and supply air temperature increase.](7d0aa3d7ae2409d2f5127d0f4e647299_img.jpg)
+
+Figure E.7: A 3D surface plot showing the relationship between Power consumption [kW], Thermal load [kW], and Supply air temperature [°C]. The vertical axis (Power consumption) ranges from 0 to 30 kW. The horizontal axis (Thermal load) ranges from 0 to 75 kW in increments of 15. The depth axis (Supply air temperature) ranges from -10 to 40 °C in increments of 10. The surface is a mesh grid showing that power consumption increases as both thermal load and supply air temperature increase.
+
+**Figure E.7 – Example of relation between thermal load (cooling calorific value), open air
+temperature and air-conditioner power consumption**
+
+### E.2.4 Construction of a power supply system model
+
+With power supply system devices such as PDUs, UPSs and power cables, the power loss varies by the magnitude of the electric power, and therefore, a model of this relation can be constructed (see Figure E.8). The power consumption of the whole data centre can be calculated by integrating the power losses in power supply systems for the various power paths in the data centre, after calculating the power consumption of ICT devices and air-conditioning equipment.
+
+![Figure E.8: A 2D line graph showing the UPS's power loss model. The vertical axis is 'Power loss [kW]' ranging from 0 to 2.5. The horizontal axis is 'Power load [kW]' ranging from 0 to 50. A blue curve starts at approximately 0.9 kW at 0 load and curves upwards to approximately 2.2 kW at 45 kW load.](fcdcb5991d671cadf547dd3fbfe13486_img.jpg)
+
+Figure E.8: A 2D line graph showing the UPS's power loss model. The vertical axis is 'Power loss [kW]' ranging from 0 to 2.5. The horizontal axis is 'Power load [kW]' ranging from 0 to 50. A blue curve starts at approximately 0.9 kW at 0 load and curves upwards to approximately 2.2 kW at 45 kW load.
+
+**Figure E.8 – Example of UPS's power loss model**
+
+## E.3 Control method to minimize energy consumption
+
+The workload in a data centre varies with the time of day and with the season. Calculation of resource distribution and energy used for air conditioning on a daily and seasonal basis is necessary for effectively reducing overall power consumption.
+
+By using an energy model, it becomes possible to obtain the operating state of ICT devices and air-conditioning equipment for minimizing the energy consumption in the whole data centre against the workload.
+
+### E.3.1 Minimization of energy consumption by ICT devices
+
+Higher server workload results in better server energy efficiency from the power consumption characteristics of servers as shown in Figure E.4. While the workload is low, wasteful power consumption can be eliminated by concentrating the workload to partial servers to increase the workload per server and by turning off the power for the servers, to which no workload is allocated.
+
+$W_s$ is the sum of the system board power consumption of all servers. The calculation to minimize $W_s$ can be formulated as follows:
+
+minimize $W_s = \sum M_{si} (x_{si})$
+
+subject to $\sum x_{si} = x_{DC}$
+
+Where; $M_{si}$ and $x_{si}$ represent system board power consumption characteristics and workload respectively of the $i$ -th server. Furthermore, $x_{DC}$ represents the gross workload input to the data centre. Regarding power consumption characteristics $M_{si}$ of the system board, the server power is turned off and the power consumption is reduced to zero.
+
+As a point to consider, in case the cooling efficiency varies by the server location, it will be better if the load is concentrated to servers located in positions where they can be cooled with small amounts of energy. This minimization is optimized by using sensing data such as temperature or thermo-fluid simulation.
+
+#### E.3.2 Minimization of air-conditioner energy consumption
+
+With a conventional air-conditioner, it is usual that the air-conditioner is run in the state where the air-conditioner supply temperature and airflow, which are needed for the server's maximum heat value and maximum fan airflow, are set and fixed. On the contrary, for a data centre, the air-conditioner supply temperature and airflow are set to permit cooling with minimum energy as matched with heat value $W_s$ that corresponds to the workload.
+
+Figure E.9 shows the relation between elements related to the energy consumption of an air-conditioner and servers. Where the air-conditioner power consumption is expressed as $W_c$ and the server fan power consumption is expressed as $W_f$ , calculation for minimization of the total power consumption related to the air-conditioner is as follows:
+
+minimize $W_c + W_f$
+
+where $W_c = M_c(T_c, Q_c, W_{sf}, T_e)$
+
+$$W_f = \sum M_{fi} (x_{si})$$
+
+$$W_{sf} = W_s + W_f$$
+
+Where; $M_c$ represents air-conditioner power consumption characteristics, which is a function of supply temperature $T_c$ , supply airflow $Q_c$ , thermal load $W_{sf}$ and open air temperature $T_e$ . Furthermore, $M_{fi}$ and $T_{si}$ represent fan power consumption characteristics and inlet air temperature respectively of the $i$ -th server.
+
+As a point to consider, where the room is divided into a cold aisle and a hot aisle by a containment measure, reverse flow will occur unless the air-conditioner airflow is larger than the server airflow, and the air-conditioner airflow is restricted. Furthermore, air-conditioner supply temperature $T_c$ and server inlet air temperature $T_{si}$ are similar.
+
+
+
+Figure E.9: Example of power consumption characteristics related to an air-conditioner and servers. The diagram shows a 'Server' block containing 'System board model' and 'Fan model'. 'Workload' and 'Server inlet air temperature' are inputs to the 'System board model', which outputs 'Power consumption'. 'Server inlet air temperature' is also an input to the 'Fan model', which outputs 'Power consumption'. Both 'Power consumption' outputs feed into 'Heat load'. 'Heat load' and 'Airflow volume' are inputs to the 'Air-conditioner model', which outputs 'Power consumption'. 'Supply air temperature', 'Supply airflow volume', and 'External air conditions' are inputs to the 'Air-conditioner model'. A dashed arrow points from 'Supply air temperature' back to 'Server inlet air temperature'. A label 'L.1300(14)\_FE.9' is in the bottom right.
+
+**Figure E.9 – Example of power consumption characteristics related to an air-conditioner and servers**
+
+#### E.3.3 Minimization of energy consumption between multiple data centres
+
+If the workload can be distributed to multiple data centres, then it is possible to minimize the total data centre power consumption by optimizing the workload distribution to data centres.
+
+The calculation for minimizing $W_A$ , the total power consumption by all data centres against workload $x_A$ is as follows:
+
+$$\text{minimize } W_A = \sum M_{DCi} (x_{DCi}, T_{ei})$$
+
+$$\text{subject to } \sum x_{DCi} = x_A$$
+
+Where; $M_{DCi}$ , $x_{DCi}$ and $T_{ei}$ represent power consumption characteristics, workload and open air conditions respectively of the $i$ -th data centre. Open air conditions are particularly of large influence when an air-conditioning system using open air is used as the air-conditioner. The optimum distribution ratio to the workload can be determined based on what was described above.
+
+## E.4 Control system configuration
+
+An example of a control system configuration for automatically keeping the state of minimum energy against variation of workload and open air temperature is shown in Figure E.10.
+
+
+
+Figure E.10: Example of control system configuration. Part (a) shows a 'Control system in a datacenter' with a 'Computation request' input to a 'Server'. The 'Server' outputs 'Workload' to a 'Workload measurement' block, which then feeds into a 'Controller'. The 'Controller' outputs 'Server on/off' to the 'Server', 'CPU temperature' to the 'Workload measurement' block, and 'Supply air temperature' and 'airflow volume' to an 'Air-conditioner I/F' block. The 'Air-conditioner I/F' block outputs 'Rack inlet air temperature' to the 'Controller'. Part (b) shows a 'Control system of two datacenters' with a 'Computation request' input to a 'Remote load distribution' block, which then feeds into 'Datacenter 1' and 'Datacenter 2'. A label 'L.1300(14)\_FE.10' is in the bottom right.
+
+**Figure E.10 – Example of control system configuration**
+
+#### **E.4.1 Controller unit**
+
+This unit executes management of the data centre model and energy minimizing calculation. Two controls are available. One is load consolidation control that executes ICT device energy minimizing calculation, and the other is ICT linked air-conditioning control that executes the air-conditioning equipment energy minimizing calculation.
+
+##### **E.4.1.1 Load consolidation control**
+
+Upon input of the present workload, the workload allocated to each server by the energy minimizing calculation described in clause E.3.1 is calculated. To a server with no (zero) workload, a power off command is sent, and for allocating workload to a server that has been powered off, a power on command is sent.
+
+##### **E.4.1.2 ICT linked air-conditioning control**
+
+Upon input of the server operating state, temperature information and so forth, the air-conditioner supply temperature and airflow are calculated by the energy minimizing calculation described in clause E.3.2, and they are output to the air-conditioner. As a result of the energy minimizing calculation, the energy consumption of ICT devices is minimized. Server on/off commands and commands to control the air-conditioner are sent.
+
+#### **E.4.2 Workload measurement unit**
+
+This unit measures in real time, the value of the workload requested of the data centre. It is recommended that measurement is taken with a device that centrally controls the traffic in the data centre such as a network server.
+
+#### **E.4.3 Server control unit**
+
+This unit controls the workload to servers that are controlled from the control calculation unit as well as issues server power On/Off control. Server virtualization techniques are used as the method to control workload consolidation. This unit will output the server's operating states, such as CPU temperature, to the control calculation unit.
+
+#### **E.4.4 Air-conditioner I/F**
+
+An interface (I/F) that permits changes in the air conditioner temperature setting and other parameters from a remote location. The air-conditioner set temperature and airflow are input from the control calculation unit by the use of this interface.
+
+#### **E.4.5 Measurement unit (sensor)**
+
+This unit measures the rack inlet air temperature and open air temperature by sensors, collects and controls these measured values for a fixed period. It sends the measured values to the control calculation unit in correspondence to a request from the control calculation unit.
+
+#### **E.4.6 Remote load distribution**
+
+Upon input of the total workload to data centres, the workload for each data centre is allocated on the basis of results of the energy minimizing calculation described in clause E.3.3.
+
+# Bibliography
+
+- [b-ITU-T DC-MDS] ITU-T Technical Paper (2013), *Rationale for minimum data set for evaluating energy efficiency and for controlling data centre equipment in view of power saving.*
+- [b-ITU-T L.1200] Recommendation ITU-T L.1200 (2012), *Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment.*
+- [b-ITU-T TP1] ITU-T Technical Paper (2013), *Experimental studies on plates and ducts installed at equipment inlets and outlets.*
+- [b-ITU-T TP2] ITU-T Technical Paper (2013), *Case study of reduction of air-conditioning energy by optical fibre based thermometry.*
+- [b-ITU-T TP3] ITU-T Technical Paper (2013), *Potential for primary energy savings in TLC/ICT centres through free cooling.*
+- [b-ITU-T TP4] ITU-T Technical Paper (2013), *Verification experiments related to increase of efficiency of air-conditioning and control technologies at a data centre.*
+- [b-ITU-T TP5] ITU-T Technical Paper (2013), *Verification test and feasibility study of energy and space efficient cooling systems for data centres with high density ICT devices.*
+- [b-ITU-T Val] ITU-T Technical Paper (2013), *Validation test of a data centre cooling method using renewable energy in a cold region.*
+- [b-ISO/IEC 30134-2] ISO/IEC 30134-2, *Information Technology – Data Centres – Key Performance Indicators – Part 2: Power Usage Effectiveness (PUE).*
+- [b-ETSI EN 300 019-1-3] ETSI EN 300 019-1-3 (1992), *Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-3: Classification of environmental conditions; Stationary use at weather protected locations.*
+- [b-ETSI ES 202 336] ETSI ES 202 336 (in force), *Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks).*
+- [b-ASHRAE TC 9.9] ASHRAE TC 9.9 (2011), *Thermal Guidelines for Data Processing Environments – Expanded Data Centre Classes and Usage Guidance.*
+- [b-EC] European Commission (2006), *Code of Conduct on Energy Efficiency and Quality of AC Uninterruptible Power Systems (UPS).*
+- [b-EC 2013] European Commission (2013), *Code of Conduct on Data Centres Energy Efficiency v4.0.5.*
+- [b-ECMA] ECMA (2011), *Smart Data Centre Resource Monitoring and Control.*
+[](http://www.ecma-international.org/publications/files/ECMA-ST-ARCH/ECMA-400%201st%20edition%20December%202011.pdf)
+- [b-SPECPower] Benchmark Methodology V2.1, *SPEC Power and Performance Methodology*, Standard Performance Evaluation Corporation.
+[](http://www.spec.org/power/docs/SPEC-Power_and_Performance_Methodology.pdf)
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1301-201505-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg b/marked/L/T-REC-L.1301-201505-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6500a90310146adf4129749b865298fffdf4a316
--- /dev/null
+++ b/marked/L/T-REC-L.1301-201505-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9ecbbc3a932d9c82c2592729d5d2bd64b132b4835c047c462cbae56727a96905
+size 35601
diff --git a/marked/L/T-REC-L.1301-201505-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/L/T-REC-L.1301-201505-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..22dc7ff0fb30f976cc1e576c45d2b7e65fa5ddc7
--- /dev/null
+++ b/marked/L/T-REC-L.1301-201505-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aa14933e776f7d0be8b2d60b81cbb6c1ee49deb5080e0281da05296f48189055
+size 6859
diff --git a/marked/L/T-REC-L.1301-201505-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/L/T-REC-L.1301-201505-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5a226326d174004ad5c8546180a99cafd7d7226f
--- /dev/null
+++ b/marked/L/T-REC-L.1301-201505-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:04da3e7ac892ce2e072394079cd714932ba1844a03f1eb85721cd023415c76ca
+size 114767
diff --git a/marked/L/T-REC-L.1301-201505-I_PDF-E/raw.md b/marked/L/T-REC-L.1301-201505-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..54bd109424b3f6d689a15c06e21701cf2322c0d1
--- /dev/null
+++ b/marked/L/T-REC-L.1301-201505-I_PDF-E/raw.md
@@ -0,0 +1,596 @@
+
+
+International Telecommunication Union
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1301**
+
+(05/2015)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Minimum data set and communication interface
+requirements for data centre energy
+management**
+
+Recommendation ITU-T L.1301
+
+ITU-T
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a stylized globe with a red lightning bolt striking across it. To the right of the globe, the text "ITU" is written in a bold, blue font, and below it, "International Telecommunication Union" is written in a smaller, blue font.
+
+ITU logo: A globe with a red lightning bolt and the text 'ITU International Telecommunication Union'.
+
+
+
+# Recommendation ITU-T L.1301
+
+# Minimum data set and communication interface requirements for data centre energy management
+
+## Summary
+
+Recommendation ITU-T L.1301 establishes a minimum data set necessary to manage data centres and telecommunication rooms in an environmentally responsible manner.
+
+The Recommendation specifies the communication interface and defines the parameters to be communicated depending on the equipment used in data centres, such as power systems (alternating current (AC)/direct current (DC) and uninterruptible power supply (UPS) and energy distribution), cooling systems and information and communication technology (ICT) equipment.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1301 | 2015-05-07 | 5 | 11.1002/1000/12428 |
+
+## Keywords
+
+Data centre, energy management.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+###### Page
+
+| | | |
+|-------|-----------------------------------------------------------------------------------------------------|----|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| 3.1 | Terms defined elsewhere ..... | 1 |
+| 3.2 | Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 2 |
+| 6 | Architecture of data centre energy management ..... | 2 |
+| 7 | Managed entities ..... | 3 |
+| 8 | General requirements for data centre energy management ..... | 3 |
+| 8.1 | Requirements for communication interfaces ..... | 3 |
+| 8.2 | Requirements for measuring data ..... | 4 |
+| 9 | Minimum data set for energy management in data centres ..... | 4 |
+| 9.1 | Minimum set of static data ..... | 4 |
+| 9.2 | Minimum set of dynamic data ..... | 5 |
+| 10 | Data definition and requirements..... | 6 |
+| 10.1 | Requirements for data items of ICT equipment ..... | 6 |
+| 10.2 | Requirements for data items of facility equipment ..... | 7 |
+| | Appendix I – Examples of an optional data set for energy management in a cloud data centre..... | 8 |
+| I.1 | Managed entities..... | 8 |
+| I.2 | Minimum data set ..... | 8 |
+| | Appendix II – Examples of use cases for a minimum data set ..... | 10 |
+| | Appendix III – Suggested accuracy value of measurement data ..... | 12 |
+| III.1 | ICT equipment..... | 12 |
+| III.2 | Cooling equipment ..... | 12 |
+| III.3 | Power equipment ..... | 12 |
+| | Appendix IV – Related standardization activities in other standards development organizations ..... | 13 |
+| IV.1 | Activities in ETSI ..... | 13 |
+| IV.2 | Activities in ECMA ..... | 13 |
+| IV.3 | Activities in IETF ..... | 13 |
+| | Bibliography..... | 14 |
+
+
+
+# Recommendation ITU-T L.1301
+
+## Minimum data set and communication interface requirements for data centre energy management
+
+## 1 Scope
+
+This Recommendation aims to:
+
+- establish a minimum data set necessary to manage data centres in an environmentally responsible manner;
+- establish high-level interface requirements for information and communication technology (ICT) and facility equipment communication that contribute to energy saving, energy management and energy-saving evaluation.
+
+## 2 References
+
+None.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 communication interface:** An interface through which the management system communicates with the facility equipment and ICT equipment.
+
+**3.2.2 data centre:** A physical location dedicated to computing, as well as a telecom operator location, with equipment dedicated to telecommunication functions (e.g., switching functionality, billing).
+
+**3.2.3 dynamic data:** Data that is periodically obtained from information and communication technology (ICT) equipment and facility equipment.
+
+**3.2.4 facility equipment:** Equipment that supports the information and communication technology (ICT) equipment (e.g., cooling systems and power feeding systems) used in data centres.
+
+**3.2.5 managed entity:** An entity, which is a part of an equipment, that is monitored and managed.
+
+**3.2.6 management system:** A system that collects dynamic/static data and also transmits control data through the communication interface for data centre energy management.
+
+**3.2.7 minimum data set:** A data set that shall be an essential and minimum set of data transmitted over the communication interface for data centre energy management.
+
+**3.2.8 sensor:** A device that transforms a physical value (e.g., temperature, current) into an electrical or logical unit. The sensor can be directly connected with a data stream to the management system or via a conversion device.
+
+**3.2.9 static data:** Data which is constant during operation, such as: specification, configuration and location information.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|------------------------------------------|
+| AC | Alternating Current |
+| CPU | Central Processing Unit |
+| CRAC | Computer Room Air Conditioner |
+| DC | Direct Current |
+| ICT | Information and Communication Technology |
+| ID | Identifier |
+| PDU | Power Distribution Unit |
+| THD | Total Harmonic Distortion |
+| UPS | Uninterruptible Power Supply |
+
+## 5 Conventions
+
+None.
+
+## 6 Architecture of data centre energy management
+
+Figure 1 illustrates the architecture of data centre energy management. It consists of information and communication technology (ICT) and facility equipment, which are managed entities, and a management system. General information on equipment called static data, is transmitted to the management system through a communication interface. Energy-related data from the managed entity should be periodically collected and delivered to the management system. The ICT and facility equipment monitors energy-related data, such as power usage and inlet temperature with an agent program or sensors and transmits them to the management system through a communication interface. The management system collects these dynamic data from the ICT and facility equipment and analyses them to produce effective information for energy-efficient data centres. The management system also transmits control data to manipulate the ICT and facility equipment to manage their energy usage through a communication interface. The requirements of the communication interface and data set from the managed entities are the scope of this Recommendation.
+
+
+
+The diagram illustrates the architecture of data centre energy management. At the top is a box labeled 'Management system' containing a database/storage icon. Below it are two boxes: 'ICT equipment' and 'Facility equipment'. Each of these boxes contains a 'Monitoring agent/sensor' (light grey rectangle) and a 'Controller' (dark grey rectangle). Arrows indicate data flow: 'Static data' from the monitoring agents/sensors to the management system, 'Dynamic data' from the monitoring agents/sensors to the management system, and 'Control data' from the management system to the controllers. A bracket on the right side, labeled 'Scope of this Recommendation', encompasses the dynamic and control data paths. A legend at the bottom identifies the icons: a cylinder for 'Database/storage', a light grey rectangle for 'Monitoring agent/sensor', and a dark grey rectangle for 'Controller'. The text 'L.1301(15)\_F01' is in the bottom right corner.
+
+Diagram of data centre energy management architecture showing Management system, ICT equipment, and Facility equipment with data flows for static, dynamic, and control data.
+
+**Figure 1 – Architecture of data centre energy management**
+
+## 7 Managed entities
+
+Managed entities for energy efficiency in data centres are categorized into ICT equipment and facility equipment. Managed entities in ICT equipment are server, storage and networking equipment. Facility equipment includes power feeding systems and cooling systems, which are infrastructures to support stable operation of data centres. The power feeding system includes a backup generator, rectifier, alternating current (AC) uninterruptible power supply (UPS), battery, power distribution unit (PDU), etc. The cooling system includes a chiller, cooling tower, economizer, computer room air conditioner (CRAC), modular cooling systems, humidifier, etc. These are the managed entities that should be identified and managed. Specification, configuration and location information on the managed entities are managed as static data. Operating data related to energy management such as energy consumption and temperature is periodically measured and managed as dynamic data. Table 1 shows managed entities for energy management in data centres.
+
+**Table 1 – Managed entities for energy management in data centres**
+
+| Equipment type | | Managed entities |
+|--------------------|----------------------|----------------------------------------------------------------------------|
+| ICT equipment | | Server equipment |
+| | | Storage equipment |
+| | | Networking equipment (e.g., switch, router) |
+| Facility equipment | Cooling system | Chiller |
+| | | Cooling tower |
+| | | Economizer |
+| | | Air cooling unit |
+| | | Computer room air conditioner (CRAC) |
+| | | Modular cooling systems (in-row, in-rack, in-chassis) |
+| | | Humidifier |
+| | | Outdoor air system |
+| | | Heat exchanging system |
+| | Power feeding system | Backup generator |
+| | | Rectifier |
+| | | Battery |
+| | | Power distribution unit (PDU) |
+| | | AC high/medium voltage power distribution system |
+| | | AC low voltage power distribution system |
+| | | AC uninterruptible power supply (UPS) |
+| | | AC/direct current (DC) converters (up to 400 V system, -48 V system, etc.) |
+| | | DC/AC inverter |
+| | | Other energy system |
+
+## 8 General requirements for data centre energy management
+
+### 8.1 Requirements for communication interfaces
+
+- Compatibility of communication interfaces should be provided in order to manage data collected from multivendor equipment in an identical way.
+
+- Data should be collected without loss and within allowable delay times through a communication interface.
+- Communication interfaces should provide a method to retain the integrity of collected data. Errors in data should be detected.
+- Communication interfaces should provide a method to gather dynamic data from a monitoring agent or sensors.
+- Communication interfaces and control data should be scalable to the number and size of items of equipment.
+- Communication interfaces and control data should be extensible to support various types of equipment, including multivendor solutions.
+
+### 8.2 Requirements for measuring data
+
+- Equipment should have a monitoring agent or sensors to gather dynamic data.
+- Equipment should hold static data and make it available to the management system.
+- Equipment should be uniquely identified also under a multivendor environment.
+- Dynamic and static data should have a unique identifier in view of the management system.
+- Data collected from equipment including multivendor solutions should consistently be maintained in the management system.
+- Data should have a specific form to be easily stored and processed in the management system.
+
+## 9 Minimum data set for energy management in data centres
+
+Data on data centre configuration (e.g., room layout) and facility connection to ICT equipment are stored in the management system.
+
+### 9.1 Minimum set of static data
+
+Data collected from equipment for energy management in data centres are about managed entities. Equipment identifiers (IDs), specifications and configurations for managed entities must be collected in order to manage operating and energy related information in data centres. Table 2 shows the minimum set of static data for energy management in data centres.
+
+**Table 2 – Minimum set of static data for energy management in data centres**
+
+| Equipment type | Data set |
+|-------------------|-----------------------------------------------------------------------------------|
+| ICT equipment | Equipment ID and description |
+| | Operating temperature range |
+| Cooling equipment | Equipment ID and description |
+| | Energy consumption characteristics of devices used to cool the refrigerant |
+| | Energy consumption characteristics of devices used to transport the refrigerant |
+| | Presence or absence of the mode controlling the amount of refrigerant transported |
+| | Temperature setting range of refrigerant supplied from the indoor unit |
+| | Temperature setting step size of refrigerant supplied from the indoor unit |
+| | Rated amount of refrigerant supplied from the indoor unit |
+| Power equipment | Equipment ID and description |
+| | Total capacity of generator, AC UPS and up to 400 V DC system |
+| | Number of battery strings and capacity of each battery string |
+| | Efficiency characteristics |
+
+### 9.2 Minimum set of dynamic data
+
+Dynamic data refers to data that is obtained from managed entities periodically for energy management in data centres. Table 3 lists the minimum data set necessary for evaluating energy efficiency and for controlling ICT and facility equipment in order to save power in data centres. "G" (Get) in the "Data flow direction" column represents data that should be obtained from equipment and "S" (Set) data represents data that should be set to equipment.
+
+**Table 3 – Minimum data set controlling ICT and facility equipment for energy saving management in data centres**
+
+| Equipment type | | Data set | Data flow direction |
+|--------------------|--|-------------------------------------------------------------------------------------|---------------------|
+| ICT equipment | | Input power | G |
+| | | Inlet temperature | G |
+| | | Power state (off mode, sleep, active) | G |
+| | | Power state (off mode, activate) | S |
+| Facility equipment | | Power state | G/S (Note 2) |
+| | | Supply air temperature | G |
+| | | Return air temperature | G |
+| | | Outdoor air temperature | G |
+| | | Temperature setting | G/S (Note 1) |
+| | | Relative humidity | G |
+| | | Power consumption | G |
+| | | Energy consumption | G |
+| | | Fan speed | G/S (Note 2) |
+| | | Output power | G |
+| | | Input power | G |
+| | | Input voltage input current of AC UPS/up to 400 V DC/ Inverter/ other energy system | G |
+| | | Battery voltage charging/discharging current | G |
+| | | Total harmonic distortion (THD) of AC system input current | G (Note 3) |
+| | | AC system power factor | G |
+
+NOTE 1 – Temperature measure is normally taken from a sensor at room level and not inside an item of cooling equipment but is considered part of the cooling system.
+NOTE 2 – Setting of this dataset is an optional functionality.
+NOTE 3 – Optional information.
+
+## **10 Data definition and requirements**
+
+### **10.1 Requirements for data items of ICT equipment**
+
+#### **10.1.1 Measured parameters for energy management**
+
+The inlet temperature and input power of the ICT equipment shall be provided as measurement parameters.
+
+In energy management, it is necessary to maintain ICT equipment that operates under varying load conditions within a specified temperature range and to monitor how much energy the equipment consumes.
+
+ICT equipment generally has a number of embedded sensors placed in necessary locations. What measured data are collected or how the data are aggregated may depend on each operator's management applications, but the abovementioned parameters, aggregated in some cases, shall be provided as common parameters for monitoring and control. Precise location information of embedded sensors in the equipment is not necessarily required.
+
+#### **10.1.2 Common identification of measured parameters**
+
+The names and IDs of sensors used for measuring data parameters are assigned by equipment vendors. Thus, when monitoring the inlet temperature of equipment, for example, it is necessary to identify the sensor name (or ID) corresponding to the inlet temperature and to configure necessary settings for each piece of equipment. This adds unnecessary inconvenience and ineffectiveness to the management operations of many equipment resources.
+
+Each parameter corresponding to the inlet temperature and input power of equipment shall therefore have a common name and/or ID that are not dependent on vendors.
+
+#### **10.1.3 Measurement interval**
+
+For energy efficient operation of ICT equipment, related data should immediately be measured and collected. Considerations on setting the interval of measurement include the importance of timeliness of data, the performance of the measuring tool and the amount of measured data. For example, it is desirable to set a very short time interval of measurement when the data varies in time or the variation of the data in time is regarded as significant. On the other hand, if the data does not vary significantly in time or if the amount of measured data is high, it may be desirable to set a longer measurement interval.
+
+Real-time measuring is not always possible due to the features and limitations of equipment measuring tools. Even though measurement is carried out in a real-time manner, a management system may not collect or store measurements in the same way. For example, when a measuring tool measures and collects data every 30 seconds from ICT equipment, a management system may average the data out over 5 minutes or 1 hour.
+
+#### **10.1.4 Indication of allowable temperature range**
+
+The use of monitoring and control shall be applied in order to maintain the temperature environment of ICT equipment within an allowable range during its operation. Parameters of threshold value(s) shall be provided as information representing such a range. Examples of thresholds are "Non critical", "Critical", "Non recoverable", etc.
+
+#### **10.1.5 Measurement resolution and accuracy of the measurement data**
+
+The accuracy of measurement values depends on a sensor's capability, stability and location, i.e., whether the sensor is embedded or externally installed. The degree of precision necessary for these factors can be determined by the deployed ICT equipment specifications, management applications, and in a broader sense, the operator's management policy, capital costs and operational costs.
+
+The accuracy of measured data, however, is essential for ensuring effective monitoring and control. First, the "resolution" of inlet temperature and input power of equipment shall be provided as the fundamental measurement unit concerning accuracy. Here "resolution" represents the smallest scale unit measurable by the sensor. Second, it is required to keep an acceptable error range of measured data in order to provide effective energy management. Therefore, the "accuracy" shall be provided as an acceptable error range of measured data.
+
+### **10.2 Requirements for data items of facility equipment**
+
+#### **10.2.1 Measured parameters for energy management**
+
+For cooling equipment, the following parameters are fundamental to energy management. Parameters related to the air-conditioning capability that the cooling system handles include supply air temperature, return air temperature, outdoor air temperature, temperature setting and relative humidity. Power and energy related parameters of cooling equipment include power consumption, energy consumption as well as the power state of the cooling equipment itself.
+
+In addition, fan speed monitoring and control functionality may be necessary. For example, the use cases of coordinated energy management to reduce hot spots, shown in Appendix II, is to be one of the important best practices for data centres. For the power equipment, the input power and output power are fundamental to energy management.
+
+#### **10.2.2 Common identification of measured parameters**
+
+The names and IDs of sensors used for measuring data parameters are assigned by equipment vendors. Thus, when monitoring the return air temperature of cooling equipment, for example, it is necessary to identify the sensor name (or ID) corresponding to the return air temperature and to configure necessary settings for each piece of equipment. This adds unnecessary inconvenience and ineffectiveness to the management operations across multivendor environments.
+
+Each measured parameter shall therefore have a common name and/or ID that are not dependent on vendors.
+
+#### **10.2.3 Measurement resolution and accuracy of the measurement data**
+
+The accuracy of measured data is essential for ensuring effective monitoring and control. Firstly, the "resolution" of measurement parameters shall be provided as the fundamental measurement unit concerning accuracy. Here "resolution" represents the smallest scale unit measurable by the sensor. Secondly, it is required to keep an acceptable error range of measured data in order to provide effective energy management. Therefore, the "accuracy" shall be provided as an acceptable error range of measured data.
+
+Appendix III contains suggested values for accuracy of measurement data.
+
+## Appendix I
+
+## Examples of an optional data set for energy management in a cloud data centre
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Appendix I is intended to present an optional data set for energy management of a cloud data centre. A cloud data centre is understood herein as a data centre used to provide mainly "cloud computing" platforms and services. The term "cloud computing" is a paradigm for enabling network access to a scalable and elastic pool of shareable physical or virtual resources with on-demand self-service provisioning and administration, for more information, see [b-ITU-T Y.3500].
+
+In a cloud data centre, ICT equipment can be virtualized and integrated into fewer systems according to resource utilization. For example, after analysing the relationship between central processing unit (CPU) utilization and the energy consumption of servers, it may be helpful to integrate distributed workloads in servers with low utilization into fewer servers for energy efficient management. For this purpose, not only the specifications of the CPU, disk and network interfaces but also their operating data should be monitored and managed.
+
+### I.1 Managed entities
+
+Managed entities in cloud data centres include server, storage and network equipment. The CPU, disk and network interface whose workload (utilization) can be measured should be included in managed entities for energy management in cloud data centres. The CPU can be a managed entity for the server and the disk can be a managed entity for storage. Networking equipment such as a switch and a router can be composed of a common chassis with line cards and ports. Thus, chassis, line cards and ports in networking equipment can be a managed entity. Table I.1 shows managed entities for energy management in cloud data centres.
+
+**Table I.1 – Managed entities for energy management in cloud data centres**
+
+| Equipment type | Managed entities | |
+|----------------|----------------------|----------------------------------------------|
+| ICT equipment | Server equipment | CPU |
+| | Storage equipment | Disk |
+| | Networking equipment | Chassis, line card, port (network interface) |
+
+### I.2 Minimum data set
+
+#### I.2.1 Minimum set of static data
+
+The minimum set of static data for energy management in cloud data centres relates to the configuration and specifications of ICT equipment. Server specification may include the number of CPUs, the number of cores and clock rate. Storage specification may include the total capacity of disks in the storage equipment. Networking equipment specification may include configurations of chassis, line cards and ports and the bandwidth (transmission rate) of network interfaces.
+
+**Table I.2 – Minimum set of static data for energy management in cloud data centres**
+
+| Equipment type | Data | Data flow direction |
+|-----------------------|------------------------------------|----------------------------|
+| ICT equipment | Server specification | G |
+| | Storage specification | G |
+| | Networking equipment specification | G |
+
+#### **I.2.2 Minimum set of dynamic data**
+
+The energy efficiency of cloud data centres could be improved if IT resource utilization is periodically collected and utilized for integrating many systems with low workloads into a few systems with high workloads. For this purpose, CPU utilization, disk utilization and network interface utilization in network equipment should be included in the minimum set of dynamic data as shown in Table I.3.
+
+**Table I.3 – Minimum set of dynamic data for energy management in cloud data centres**
+
+| Equipment type | Data set | Data flow direction |
+|-----------------------|-------------------------------|----------------------------|
+| ICT equipment | CPU utilization | G |
+| | Disk utilization | G |
+| | Network interface utilization | G |
+
+## Appendix II
+
+## Examples of use cases for a minimum data set
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Examples of use cases for a minimum data set are shown in Figure II.1.
+
+- Monitoring the temperature and power of ICT and facility equipment
+
+To achieve energy saving in a data centre, it is necessary to collect ambient information such as floor temperature distribution and power usage of ICT equipment. As shown in use case 1 of Figure II.1, energy management systems are considered to be capable of detecting hot and cold spots, improving CRAC operation and of analysing the power-usage trends of each piece of equipment by collecting the necessary ambient information from ICT and facility equipment. The inlet temperature, power usage and power state of ICT equipment are examples of dynamic data to be collected. In addition, to maintain ICT equipment within the allowable temperature range, the threshold inlet temperature of ICT equipment can be considered as an example of static data to be collected.
+
+- Coordinated control of multiple cooling units
+
+It is important that cooling units can be managed appropriately to operate ICT equipment in the data centre with stability in the appropriate temperature environment. Currently in many data centres, multiple ambient type cooling units are installed for cooling entire computer floors and these cooling units are generally controlled individually and autonomously.
+
+The concept of coordinated control of multiple cooling units is shown in use case 2 of Figure II.1.
+
+The left part of use case 2 shows a case in which multiple cooling units are operated at a uniform temperature setting in a machine room with heat load deviation. In this case, hot spots occur locally in the area with a large heat load and the environment temperature cannot be maintained properly. In addition, cold spots occur locally in areas with a small heat load and the power of cooling units is consumed ineffectively.
+
+With the issues mentioned above, the right part of use case 2 shows a solution in which multiple cooling units with individual and dynamic temperature settings and the fan mode for each cooling unit are properly controlled by the management system.
+
+To make such coordinated control possible, it is required that the management system collects the following dynamic data:
+
+- ICT equipment: inlet temperature, power consumption and power state,
+- Cooling unit: power state, temperatures (return air, supply air and outside air), temperature setting, frequency of fan, operational mode (normal operation mode, protected operation mode), power consumption and energy consumption.
+
+It is also required that the management system controls the following parameters.
+
+- Cooling unit: temperature setting.
+
+
+
+**Use case #1: Monitoring of temperature and power consumption of data centre equipment**
+
+- Detection of hot spots and overcooling
+- ⇒ Review of cooling strategy
+- Analysis of power consumption trend
+
+**Use case #2: Coordinated control of multiple cooling units**
+
+- Adjusting cooling output among units
+- ⇒ Prevention of hot spots and overcooling
+- ⇒ Efficient cooling and energy saving
+
+**Management system**
+
+**Monitoring**
+
+**Control**
+
+**ICT equipment**
+
+**Cooling units**
+
+**Equipment ID**
+Power state
+Supply air temperature
+Return air temperature
+Outdoor air temperature
+Temperature setting
+Fan frequency
+Operational mode
+Power consumption
+
+**Equipment ID**
+Power state
+Inlet temperature
+Temperature threshold
+Power consumption
+
+**Temperature setting**
+
+L.1301(15)\_FII.1
+
+Diagram illustrating two use cases for a minimum data set in a data center. Use case #1: Monitoring of temperature and power consumption of data centre equipment. Use case #2: Coordinated control of multiple cooling units. The diagram shows a Management system connected to ICT equipment and Cooling units via Monitoring and Control paths.
+
+**Figure II.1 – Examples of use cases for a minimum data set**
+
+## Appendix III
+
+## Suggested accuracy value of measurement data
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### III.1 ICT equipment
+
+Suggested accuracies of measurement data of ICT equipment may be:
+
+For input power: $\pm 3\%$ from 25% to 100% load and $\pm 5\%$ below 25% load
+
+For inlet temperature: $\pm 1^\circ\text{C}$ in the range of $20\text{-}50^\circ\text{C}$
+
+As a means for ICT equipment to achieve required accuracy, the following can be considered.
+
+Employing sensor hardware with required accuracy
+
+Executing some software processes on measurement data (e.g., calculating a mean value of multiple sensors data)
+
+### III.2 Cooling equipment
+
+Suggested accuracies of measurement data of cooling equipment may be:
+
+For air temperature: $\pm 0.5^\circ\text{C}$ in the range of $20\text{-}50^\circ\text{C}$
+
+For relative humidity: $\pm 5\%$
+
+For power consumption: $\pm 2\%$
+
+For energy consumption: $\pm 2\%$
+
+### III.3 Power equipment
+
+Suggested accuracies of measurement data of power equipment may be:
+
+For voltage: $\pm 1\%$
+
+For current: AC current $\pm 1\%$ , DC current $\pm 5\%$
+
+## Appendix IV
+
+## Related standardization activities in other standards development organizations
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Other standardizing organizations and initiatives study and address energy management aspects of facility and ICT equipment at telecommunication and data centre sites.
+
+### IV.1 Activities in ETSI
+
+[b-ETSI ES 300 202 336-1] defines a generic interface that applies to monitoring and control of the infrastructure environment, i.e., power, cooling and building environment systems for telecommunication centres. Further, [b-ETSI ES 300 202 336-12], as a related document series, is under development. This applies to a monitoring and control interface for telecom/ICT equipment power, energy and environmental parameters in telecommunication or data centres or customer premises.
+
+It discusses measurement both inside and outside of equipment, metrics and conditions such as input voltages and currents of equipment, air temperature and humidity at inlets and precision and accuracy, for larger and more complex sites that have many types of equipment provided by different manufacturers.
+
+### IV.2 Activities in ECMA
+
+[b-ECMA-400] describes modelled resources by using common information models (CIMs) of IT and facility equipment, systems and components in a data centre.
+
+IT systems refer mainly to computer systems and facility equipment refers to cooling systems. The energy management aspect of computer systems deals with properties of the input power and detailed power statuses.
+
+### IV.3 Activities in IETF
+
+[b-IETF RFC 7326] defines an energy management framework for devices within or connected to communication networks. The devices, or components of these devices (such as router line cards, fans and disks), can then be monitored and controlled. [b-IETF RFC 6988] defines requirements. [b-IETF RFC 7461] and [b-IETF RFC 7460] provide energy management related management information base (MIB) information to cover energy management functionality that is not covered by the Telecommunications Management Network model.
+
+Energy management objects applied to network equipment include, for example, measured power, measurement caliber (actual/estimated/presumed), power consumption over a certain interval, unit multiplier and accuracy. In addition, relationships are provided as powered by/powering, metered by/metering and aggregated by/aggregating.
+
+## Bibliography
+
+- [b-ITU-T Y.3500] Recommendation ITU-T Y.3500 (2014), *Information technology – Cloud computing – Overview and vocabulary.*
+- [b-ETSI ES 202 336-1] ETSI ES 202 336-1 (2011), *Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks) Part1: Generic Interface.*
+- [b-ETSI ES 202 336-12] ETSI ES 202 336-12 (2015), *Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (power, cooling and building environment systems used in telecommunication networks); Part 12: ICT equipment power, energy and environmental parameters monitoring information model.*
+- [b-IETF RFC 6988] IETF RFC 6988 (2013), *Requirements for Energy Management.*
+- [b-IETF RFC 7326] IETF RFC 7326 (2014), *Energy Management Framework.*
+- [b-IETF RFC 7460] IETF RFC 7460 (2015), *Monitoring and Control MIB for Power and Energy.*
+- [b-IETF RFC 7461] IETF RFC 7461 (2015), *Energy Object Context MIB.*
+- [b-ECMA-400] ECMA-400 (2013), *Smart Data Centre Resource Monitoring and Control.*
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1307-202403-I_PDF-E/raw.md b/marked/L/T-REC-L.1307-202403-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..e71c8031fb9341c4fb2057b89353f3435efac6c4
--- /dev/null
+++ b/marked/L/T-REC-L.1307-202403-I_PDF-E/raw.md
@@ -0,0 +1,400 @@
+
+
+# Recommendation **ITU-T L.1307 (03/2024)**
+
+SERIES L: Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant
+
+Energy efficiency, smart energy and green data centres
+
+---
+
+# **Energy efficiency in micro data centres for edge computing**
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features the letters "ITU" in a bold, blue, sans-serif font, superimposed on a stylized globe icon with intersecting lines.
+
+ITU logo
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+### **Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant**
+
+| | |
+|---------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | L.100-L.199 |
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+| OPTICAL INFRASTRUCTURES | L.200-L.299 |
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+| MAINTENANCE AND OPERATION | L.300-L.399 |
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000-L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200-L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300-L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400-L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500-L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600-L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700-L.1799 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T L.1307
+
+# Energy efficiency in micro data centres for edge computing
+
+## Summary
+
+With the advent of the artificial intelligence era, the demands for edge computing to provide ultra-low latency for various services that require high computation power continue to grow. The demand for micro data centres, an essential item of equipment for delivering edge computing services near users, is also growing. Recommendation ITU-T L.1307 presents considerations on micro data centres for edge computing services in energy efficiency aspects. In addition, it presents the management information needed to manage micro data centres' energy efficiency and provides a metric for evaluating the energy performance of micro data centres. Finally, it presents energy efficiency issues in the operation of edge computing services and methods to address them.
+
+## History\*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T L.1307 | 2024-03-08 | 5 | 11.1002/1000/15767 |
+
+## Keywords
+
+Edge computing, energy efficiency, energy efficiency indicator, management, micro data centre.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2024
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|----------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Overview of edge computing and micro data centres ..... | 2 |
+| 7 Considerations on micro data centre for edge computing ..... | 3 |
+| 8 Energy-efficient management of micro data centre..... | 4 |
+| 9 Energy-Efficient Indicator for micro data centre..... | 6 |
+| 10 Energy efficiency in edge computing ..... | 7 |
+| Appendix I – Applying renewable energy to micro data centres..... | 10 |
+| I.1 Recommended renewable energy types ..... | 10 |
+| I.2 Photovoltaic power plant requirements for micro data centres ..... | 10 |
+| I.3 Method to incorporate the PV power plant with micro data centres ..... | 10 |
+| Bibliography..... | 12 |
+
+
+
+# Recommendation ITU-T L.1307
+
+# Energy efficiency in micro data centres for edge computing
+
+## 1 Scope
+
+This Recommendation describes considerations for improving the energy efficiency of micro data centres, which are essential items of equipment for edge computing services, and how to operate them efficiently from an energy perspective. In this respect, this Recommendation focuses on:
+
+- Considerations on micro data centres for edge computing: deployment, configuration including redundancy and components;
+- Energy efficiency in micro data centres: management functions including energy efficiency and operation perspective;
+- Energy efficiency in edge computing: management functions including energy efficiency and operation perspective.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ISO/IEC 30134-2] ISO/IEC 30134-2:2016, *Information technology – Data centres – Key performance indicators – Part 2: Power usage effectiveness (PUE)*.
+
+[ISO/IEC 30134-5] ISO/IEC 30134-5:2017, *Information technology – Data Centres – Key performance indicators – Part 5: IT Equipment utilization for servers (ITEUsv )*.
+
+# 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 edge computing** [b-ITU-T Y.3073]: This refers to a strategy to deploy processing capability at network edge where end terminals are connected, and to perform the processing of data which is derived from and fed to the end terminals.
+
+**3.1.2 power usage effectiveness (PUE)** [ISO/IEC 30134-2]: Ratio of the data centre total energy consumption to information technology equipment energy consumption, calculated, measured or assessed across the same period.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 micro data centre energy efficiency indicator**: A metric used to assess and quantify the energy efficiency of a micro data centre.
+
+NOTE – This metric can be calculated based on the relation of server central processing unit (CPU) utilization and PUE.
+
+**3.2.2 micro data centre:** A solution designed to provide processing, storage and networking capabilities in a more compact and modular form.
+
+NOTE 1 – This solution is used in edge data centres; see [b-ITU-T L.1306].
+
+NOTE 2 – Micro data centres are typically deployed to address specific needs such as edge computing, where computing resources are placed closer to where data is generated or needed. This can improve performance, reduce latency and enhance overall efficiency for applications that require real-time processing or low-latency communication.
+
+**3.2.3 Offloading:** The process of transferring an application from a device with limited computation resources to one or more remote devices with more resources.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------------------|-----------------------------------------------------|
+| CPU | Central Processing Unit |
+| EEI MDC | Energy Efficiency Indicator for a Micro Data Centre |
+| ITEU sv | IT Equipment Utilization for servers |
+| MDC | Micro Data Centre |
+| PDU | Power Distribution Unit |
+| PUE | Power Usage Effectiveness |
+| PV | Photovoltaic |
+| UPS | Uninterruptible Power Supply |
+
+## 5 Conventions
+
+None.
+
+# 6 Overview of edge computing and micro data centres
+
+Emerging services such as autonomous vehicles, artificial intelligence and augmented reality require high-performance computing power and ultra-low latency. Cloud computing has high-performance computing resources, but it is far from user terminals that require services, which inevitably causes transmission delays. This has led to the emergence of edge computing, which can provide computing resources at the edge of the network closer to the users. By offloading tasks from the user terminal to edge computing, it is possible to use high-performance computing resources as well as to extend the battery life of the user terminal.
+
+The advantages provided by edge computing are as follows. Since computing resources are provided closer to the user, transmission delay can be reduced, and the service provisioning time can be shortened. It does not use cloud computing in the network core, so it does not consume network bandwidth in the core. It is easy to use location-based services or network context information because computing services are provided at the base station or on the premises where the user is located. However, there may be a lack of usable computing resources, in contrast to those available to cloud computing, so offloading to nearby edge computing or cloud computing in the core may be necessary.
+
+Edge computing aims to provide the computing resources required by a user terminal near the user's location, but the location of actual edge computing equipment may vary depending on service providers. A micro data centre can provide computing resources for edge computing services. Micro data centres are typically deployed to address specific needs such as edge computing, where computing resources are placed closer to the location where data is generated or needed. This can improve performance, reduce latency and enhance overall efficiency for applications that require real-
+
+time processing or low-latency communication. A micro data centre is a smaller or containerized data centre that is designed to provide processing, storage and networking capabilities in a more compact and modular form.
+
+Depending on the deployment location, there are restrictions on the operation and management of the micro data centre, including service quality such as delay, energy consumption, network bandwidth consumption and rental fee. Figure 1 shows possible locations of micro data centres for edge computing services. The closest location to users is achieved by deploying a micro data centre to Wi-Fi apps in homes or public places. Micro data centres can be deployed in corporate premises such as enterprises or smart factories to provide their own edge computing services. In the case of mobile network operators, micro data centres can be deployed in base stations. Depending on the coverage of the base station, it is possible to provide edge computing services in a smaller unit by placing it in a small cell of about 1 km or by placing it in a femtocell or picocell in a building. It is also possible to deploy micro data centres in base stations (eNodeB, gNodeB) that cover macro cells in a range of several kilometres. These options may depend on the service strategy provided by the edge computing provider.
+
+
+
+The diagram illustrates the network architecture for edge computing. At the top left, a 'WiFi AP' (represented by a router icon) is connected to a 'Multi-tech cell aggregation site' (represented by a tower icon). Below the WiFi AP, an 'On-premise' base station (tower icon) and a 'Small cell BS' (tower icon) are also connected to the aggregation site. The aggregation site is connected to the 'Internet' cloud (represented by a cloud icon), which in turn is connected to a 'Cloud' server (represented by a server rack icon). A 'Macro cell BS (eNB or gNB)' (tower icon) is connected to the aggregation site. A dashed box labeled 'Micro data centre (MDC)' (represented by a server rack icon) is shown separately, indicating its potential deployment location. The diagram is labeled 'L.1307(24)' in the bottom right corner.
+
+Diagram illustrating the location of micro data centres (MDC) for edge computing. The diagram shows various network components connected to a central 'Multi-tech cell aggregation site'. On the left, a 'WiFi AP', 'On-premise' base station, and 'Small cell BS' are connected. On the right, a 'Macro cell BS (eNB or gNB)' is connected. The 'Multi-tech cell aggregation site' is connected to the 'Internet' cloud, which is further connected to a 'Cloud' server. A dashed box labeled 'Micro data centre (MDC)' is shown separately, indicating its potential deployment location.
+
+Figure 1 – Location of micro data centres for the realization of edge computing
+
+# 7 Considerations on micro data centre for edge computing
+
+If a micro data centre is placed in a dedicated space such as a traditional data centre, there is not much to consider from an energy efficiency perspective. However, additional considerations arise as the location of micro data centres may vary depending on edge computing service providers and their applications. Depending on edge computing service providers, the micro data centre can be placed in a general office, a communication room, a base station site, a central office, etc. It can be placed inside the building, or it can be placed outside the building depending on the policy of the operating company. When a micro data centre is placed in a non-dedicated space such as a general office or a commercial building, there are restrictions on the noise and vibration it causes. In order to supply stable power, an intelligent power distribution device and an uninterruptible power supply (UPS) are necessary. The capacity of the UPS must be calculated to continuously supply power to servers until it is replaced with an alternative power source in the event of a power outage. When a micro data
+
+centre is placed in a general building supplied by commercial power, it is necessary to ensure that sufficient power is supplied for the operation of the micro data centre and the building. It is recommended to separate the electrical power distribution for the micro data centre and the office. Since a cooling system for thermal control of servers is not provided in general office spaces, a cooling system should be equipped with a micro data centre. A management system (or software) for the data centre is necessary to manage computing resources and measure energy efficiency. Micro data centres deployed outdoors require strong physical security devices to protect against external intrusion. Table 1 summarizes the general requirements for micro data centres for edge computing.
+
+**Table 1 – Requirements for micro data centres for edge computing**
+
+| Category | General requirements |
+|---------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Power supply | The power supply shall be configured in consideration of the maximum power that can be consumed by the servers, storages, network equipment, cooling system and other security and operation equipment constituting the micro data centre. It is recommended to separate electrical power distribution between the data centre and other service present in the site. |
+| Redundancy | Possible failures include server failure, storage and network equipment failure, cooling system failure, power outage and power supply failure. Backup servers in a rack can be used to protect against server failures or servers operated by other micro data centres can be used as backups through task offloading. UPS should be fitted to prepare for power outages. It is desirable to provide the battery capacity of the UPS to provide a backup time of 5–10 minutes to protect from power outage; protection from power failure can be implemented using UPS and power distribution system in redundancy mode. |
+| Virtualization | Since the main characteristic of edge computing technology is to process the computing of the user terminal instead, all computing resources in the micro data centre should be provided through virtualization. It is required to provide computing resources through virtual machines or container technology, network function virtualization and software-defined networking. |
+| Computing capacity planning | It is necessary to expand the capacity of computing resources as service demands from users increase. It is possible to expand computing resources from virtual machines to server units and up to rack units. In the case of the expansion of rack units, the power capacity of the building in which it is located should also be considered. Before physical expansion, computing offloading to a nearby micro data centre or a central cloud data centre is recommended. |
+| Operation and management system | A management system is required to monitor environmental conditions such as temperature and humidity, and the operational status of computing resources and power consumption in order to optimize the operating condition. |
+| Noise and vibration | If a micro data centre is placed in a general office (indoor), it is recommended that noise and vibration that the micro data centre causes not hinder the normal working for workers in the same place. If a micro data centre is placed outside, the restriction of noise and vibration can be relaxed. It is necessary to introduce an enclosed rack enclosure for noise and vibration reduction. |
+| Physical security | When a micro data centre is placed in a general office building rather than a dedicated place in a data centre, it could be easily accessible to the general public. Thus, it requires strong physical security and access-limiting technologies. |
+
+## 8 Energy-efficient management of micro data centre
+
+Micro data centres should be managed in the aspects of computing resources and energy consumption. IT-related resources such as servers, storage and networks should be managed to immediately provide computing resources to users who request edge computing services. Server virtualization or container technology can be applied for the efficient management of physical server resources. For this purpose,
+
+the utilization of server CPU, memory and storage should be monitored and managed. If the resources of the micro data centre are insufficient to provide the computing resources that users request, they can offload the computing resource to a nearby micro data centre or to cloud computing. Computing resources and facilities that the micro data centre should monitor and manage are presented in Table 2.
+
+Energy consumption and power saving are important management issues in micro data centres. So, it is necessary to periodically collect power consumed by various equipment in the micro data centre. It is very important to effectively remove the heat generated by the servers. This is for the stable operation of the servers as well as power saving of the cooling system. Therefore, it is necessary to collect temperature data in the data centre and operate the cooling system in an energy-efficient way. Table 2 additionally shows the data to be collected for energy management. These can be used to evaluate the energy efficiency of the micro data centre.
+
+**Table 2 – Resource items for energy-efficient managing micro data centres**
+
+| Equipment | Managed data | Computing resources related data | Energy consumption related data |
+|------------------|-------------------------------------------------------------------------------|------------------------------------------------------------|---------------------------------------------------------------|
+| Server | Location, years, spec. (CPU, memory, disks, etc.) | Physical/virtual server CPU, memory, disk, I/O utilization | Energy consumption, temperature |
+| Storage | Location, years, spec. (storage capacity) | Storage utilization | Energy consumption, temperature |
+| Network | Location, years, spec. (bandwidth, ports, protocols, etc.), IP address, cable | Port utilization | Energy consumption |
+| Rack | Rack ID (incl. location), server/storage/network configuration | | Slots/ports used information, energy consumption, temperature |
+| Service | Service list (service periods, used resources, on-/offload, users, etc.) | Resource utilization per service | |
+| Power supply | Power system capacity (PDU, UPS) | | Energy consumption (input/output) |
+| Cooling system | Cooling capacity | | Energy consumption |
+| Others | Security systems (camera, etc.) | | Energy consumption |
+
+A management system for micro data centres can be built in on-site or a remote place. The on-site management system can be accessed by a manager on the spot to monitor the current state of computing resources and energy consumption in the micro data centre. If a manager is in a remote location, the micro data centre can be operated and managed by remote access through the Internet. A management system can monitor and manage more than one micro data centre. A micro data centre manager could coordinate the computing resources in several micro data centres for task offloading.
+
+The basic principle of task offloading is to provide the resources of other edge computing to accommodate the needs of users who exceed the capacity of edge computing. However, from an energy point of view, if energy consumption is excessive in one micro data centre, it may choose to offload tasks to another micro data centre with lower energy consumption, consequently the overall energy consumption of all micro data centres could be minimized. Therefore, the management system of the micro data centre should not be limited to simply managing computing resources, but should also be managed in terms of energy consumption at the same time.
+
+# 9 Energy-Efficient Indicator for micro data centre
+
+For evaluating the energy efficiency of a data centre, Power Usage Effectiveness (PUE) is widely used as a performance indicator. PUE is the ratio of total power consumed in the data centre to the power consumed by IT equipment [ISO/IEC 30134-2]. It shows how much additional power is required to provide IT services. However, micro data centres may not have a backup power supply or cooling system to a similar level to the typical data centre, so this indicator should not be used as it is.
+
+To measure the energy efficiency of micro data centres, both the power consumed in a micro data centre and the utilization of servers in the data centres are considered. These two factors are used in performance indicators for the following reasons. Energy efficiency can be achieved by fundamentally reducing the power consumed in the data centre. According to Beloglazov et al. [b-Beloglazov], the server consumes minimum energy even in an idle state, and power consumption increases linearly as the server utilization rate increases as follows.
+
+$$P(u) = kP_{\max} + (1 - k)P_{\max} \cdot u \quad (1)$$
+
+$P_{\max}$ the maximum power consumed at a server utilization of 100%;
+
+$K$ the fraction of power consumed by the idle server;
+
+$u$ the CPU utilization of the server.
+
+Therefore, it is better in terms of energy efficiency to integrate and operate several tasks on a small number of servers using virtualization technology rather than to operate a large number of servers that are driven at low utilization rates. That is, the higher the average utilization rate of the servers and the lower the power consumption of the servers, the higher the energy efficiency of the micro data centre.
+
+Considering these points, the performance indicator for energy efficiency of a micro data centre should consider both the server utilization and the power consumption. The server utilization in a micro data centre can be obtained from IT Equipment Utilization for servers ( $ITEU_{sv}$ ) [ISO/IEC 30134-5]. $ITEU_{sv}$ describes the average CPU utilization of the servers in a data centre. The average CPU utilization of the servers at time $t$ in a micro data centre can be described by
+
+$$ITEU_{sv}(t) = \sum_{i=1}^N \frac{U_i(t)}{N} \quad (2)$$
+
+$U_i(t)$ CPU utilization rate of server $i$ at time $t$ ;
+
+$N$ the number of running servers in a micro data centre at time $t$ .
+
+Since the CPU utilization of a server and the running servers change over time, $ITEU_{sv}$ should be monitored and measured at a specific time interval during a given measurement period, for example, a year. The maximum value of $ITEU_{sv}(t)$ should be used at every measurement time interval. $ITEU_{sv}$ is a metric for server based on CPU utilization, so it does not apply to storage systems or network equipment in a data centre. More detailed and specific method for calculating $ITEU_{sv}$ can be found in [ISO/IEC 30134-5].
+
+If multiple servers with low utilization are integrated into a small number of servers using server virtualization technology, the $ITEU_{sv}$ value will increase. As a result, power consumption in micro data centres is also expected to decrease. If the amount of power consumed by infrastructure facilities such as power supply and cooling equipment decreases in proportion to the amount of power saved by the server, PUE, which is widely used as a data centre performance indicator, can reveal the power saving effect well, but otherwise may not show the effectiveness of server consolidation. Therefore, the following performance indicator can be used to show energy efficiency in microdata centres in consideration of server utilization and power consumption.
+
+$$EEI_{MDC} = \frac{ITEU_{sv}}{PUE} \quad (3)$$
+
+The energy efficiency indicator for a micro data centre ( $EEI_{MDC}$ ) can be explained as follows. In the case of a microdata centre operating with multiple servers with low utilization, $ITEU_{sv}$ will have a low value due to the low CPU utilization, and PUE will show a high value because the power consumption of infrastructure facilities is relatively high compared to the amount of power consumed by IT equipment. Consequently, $EEI_{MDC}$ will show a low value. On the other hand, in the case of a micro data centre operated with servers with high CPU utilization, the $ITEU_{sv}$ value will be high, and the PUE will be slightly lower or a similar level to the former case. Therefore, $EEI_{MDC}$ will have a high value. That is, it can be determined that the higher the value of $EEI$ , the higher the energy efficiency of the micro data centre.
+
+# 10 Energy efficiency in edge computing
+
+Energy efficiency is a critical issue in edge computing, as the increasing number of connected devices and the amount of data they generate are putting a strain on the power grid. Here are some of the main issues of energy efficiency in edge computing:
+
+- The distributed nature of edge computing. Edge servers are typically located closer to the end users, which means that there are more of them and they are more dispersed. This makes it difficult to manage and optimize their energy consumption.
+- The limited resources of user terminals. User terminals often have limited resources, such as battery power and processing power. This means that they can only handle a certain amount of workload before they start to run out of power.
+- The high volume of data traffic. User terminals need to communicate with edge servers in a micro data centre and with the cloud, which can generate a lot of data traffic. This data traffic can also consume a lot of energy.
+- The need for real-time processing. Some edge applications require real-time processing, which means that the data cannot be sent to the cloud for processing. This can also lead to increased energy consumption.
+
+Considering these points, the following solutions can be applied to improve the energy efficiency of edge computing.
+
+- Data compression can be used to reduce the amount of data that needs to be transmitted and processed. This is especially useful in situations where large amounts of data transfer are required to process and deliver the training data required to build a machine learning training model.
+- Edge servers in a micro data centre should be used to process the data that is generated closest to them. This can help to reduce the amount of data traffic and the energy consumption of edge servers. For example, if a micro data centre is located in a factory, it should be used to process the data that is generated by the machines in that factory.
+- Task offloading can be performed when there are limited resources to process tasks in a user terminal. From an energy efficiency perspective, it is possible to select which servers to offload tasks to, including a cloud computing server based on the cooperative orchestration.
+- Virtualization can be used to consolidate multiple workloads onto a single server. This can help to reduce the number of servers that are needed, which can lead to reduced energy consumption. For example, multiple sensors can be connected to a single server, which can then transmit the data to the cloud.
+
+In addition to these considerations, it is necessary to ensure that the offloading techniques popular in edge computing are efficient from an energy perspective. Offloading can be defined as the process of executing an application from a device with limited computation resources to single or multiple remote devices with more resources. There are two types of offloading: data offloading and computation offloading. Data offloading transfers data from a mobile device with limited storage to
+
+a cloud repository. Computation offloading transfers computation processes of intensive applications to be performed remotely using powerful cloud or edge servers in a micro data centre, overcoming limitations on mobile CPU and battery. The architecture of an offloading system is shown in Figure 2.
+
+
+
+Figure 2 – Offloading architecture diagram. The diagram illustrates the flow of data and tasks between user devices, edge servers, and cloud servers. On the left, 'Devices' (laptop and smartphone) are connected to an 'Edge computing' node. A legend indicates: solid line for 'Data and task', dashed line for 'Result', and gears for 'Processing'. The 'Edge computing' node contains a 'Computing offload' box and a network of small servers. Arrows show data/tasks moving from devices to the edge node, and results returning. From the edge node, data/tasks are offloaded to a 'Cloud computing' node (represented by a cloud with servers) and a 'Data centre' (represented by a rack of servers). Results from both cloud and data centre return to the edge node, and finally to the devices. A label 'L.1307(24)' is in the bottom right corner.
+
+**Figure 2 – Offloading architecture**
+
+In edge computing, offloading can be done vertically or horizontally. In vertical offloading, an application from a user terminal (i.e., smart mobile device) can be offloaded to nearby edge servers in a micro data centre. Meanwhile, in horizontal offloading, an application from an edge server can be offloaded to other nearby edge servers. Offloading is performed to reduce energy consumption in user terminals, extend user terminals' battery life, and reduce application runtime. Since offloaded tasks are usually executed on edge servers, it is also important to consider energy efficiency in terms of task execution in these servers. To achieve energy-efficient offloading, some aspects need to be considered such as latency, task scheduling, resource allocation and battery life. Table 3 presents several items to consider energy-efficient offloading techniques in edge computing.
+
+**Table 3 – Considerations on energy-efficient offloading in edge computing**
+
+| Category | Considerations |
+|---------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Network latency | Network latency is crucial in edge computing offloading. It affects the time taken for computation results to return to the user terminal. Reducing latency is key to improving offloading performance. Communication protocol optimization, reduced data transfer sizes, network path selection, caching/pre-fetching, and edge computation offloading can help minimize latency. |
+| Task scheduling | In edge computing, task scheduling and offloading are techniques that impact energy consumption. Task scheduling optimizes task execution by considering resources and demands, while offloading reduces energy usage on user terminals by transferring tasks to a remote edge server. Coordination of these techniques can lead to improved energy efficiency in edge computing. |
+| Resource allocation | Resource allocation is also critical in offloading to ensure that computing resources are used efficiently. Offloaded tasks should be assigned to the most appropriate computing resource to minimize energy consumption. |
+| Battery life | To extend the battery life of user terminals, offloading should be designed to minimize the energy required for computation tasks of user terminal. |
+
+## Appendix I
+
+### Applying renewable energy to micro data centres
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes methods and requirements to incorporate renewable energy in micro data centres to improve energy efficiency and minimize the carbon footprint.
+
+### I.1 Recommended renewable energy types
+
+Abundant renewable energy sources are available nowadays, whether they are solar-powered, hydro-powered, wind-powered or geothermal-powered. For hydro, wind and geothermal, the plant to convert these energies into electricity should be constructed in certain places to optimize energy harvesting. It is because hydro, wind and geothermal energy are not available in all areas. Meanwhile, solar energy can be harvested in all areas as long as it receives direct sunlight exposure. Also, solar energy can be constructed in a highly flexible format and capacity. Hence, solar energy is the most viable renewable energy source that can be incorporated into micro data centres.
+
+### I.2 Photovoltaic power plant requirements for micro data centres
+
+To incorporate the photovoltaic (PV) power plant with micro data centres, the PV power plant should have certain requirements and configurations. The requirements and configuration of the PV power plant are as follows:
+
+- Equipped with enough PV panel
+
+The size of the PV panel should be larger than the required power for micro data centres. The energy produced by the PV panel is not steady, but it is highly stochastic. Hence, the average one-day power generation should be larger than the required power for micro data centres.
+
+- Equipped with an energy storage system
+
+An energy storage system must be installed in the PV power plant. The energy storage system stores the generated power from the PV panel during the high generation of solar power. This energy storage system will release the stored energy to supply power for micro data centres during low generation of solar power (during the night or cloudy weather).
+
+- Equipped with solar charge controller
+
+The solar charge controller maintains the charge and discharge mechanisms of the energy storage system. The solar charge controller regulates the power that the PV panel produces, and if the energy storage system is empty, it will charge. Meanwhile, if the energy storage system is full, then the generated power is sent directly to the system by the solar charge controller.
+
+### I.3 Method to incorporate the PV power plant with micro data centres
+
+Incorporating the PV power plant with micro data centres can be done by integrating power from the conventional grid and the PV power plant to supply power for data centres. PVs can be installed on data centre buildings to collect solar power. Since solar power generation depends on the weather and time of day, it is necessary to combine renewable energy sources with conventional power from the grid, as shown in Figure I.1.
+
+An energy management system (EMS) is important to combine renewable energy sources with the power grid. The EMS has the function of optimizing the utilization of power from renewable energy sources and minimizing power usage from the power grid. By implementing that method, the carbon footprint of the micro data centre operation can be minimized. Then, since the energy usage from the power grid is minimized, the energy cost of consuming the power is reduced.
+
+
+
+The diagram illustrates a power system architecture for a micro data centre. On the left, a 'Utility grid' represented by power lines and towers provides AC power (blue line). This line passes through a 'Circuit breaker' and then splits. One path goes to an 'Energy management system' (represented by a monitor icon). The other path goes to an 'Inverter'. A 'PV panel' (solar panel) is connected to a 'Solar charge controller', which is connected to an 'Energy storage system' (represented by two battery icons). The 'Solar charge controller' also connects to the 'Inverter'. The 'Inverter' outputs AC power (blue line) to the 'Energy management system'. The 'Energy management system' is connected to a 'Micro data centre' (represented by three server racks). A legend indicates that blue arrows represent AC power flow and red arrows represent DC power flow. The DC power flow is shown from the PV panel through the Solar charge controller to the Energy storage system, and then from the Energy storage system to the Inverter.
+
+Diagram showing the integration of renewable energy sources (PV panel) and conventional power (Utility grid) to power a micro data centre. The diagram illustrates AC and DC power flows between components including a Solar charge controller, Inverter, Energy storage system, Circuit breaker, Energy management system, and Micro data centre.
+
+L.1307(24)
+
+**Figure I.1 – Integration between renewable energy sources with conventional power from the grid to power a micro data centre.**
+
+Another example of application of renewable energy to a micro data centre can also be found in clause 8.1.4 in [b-ITU-T L.1306].
+
+## Bibliography
+
+- [b-ITU-T L.1306] Recommendation ITU-T L.1306 (2023), *Specification of an edge data centre infrastructure*.
+- [b-ITU-T Y.3073] Recommendation ITU-T Y.3073 (2019), *Framework for service function chaining in information-centric networking*.
+- [b-Beloglazov] A. Beloglazov, J. Abawajy and R. Buyya (2012), *Energy-aware Resource Allocation Heuristics for Efficient Management of Data Centers for Cloud Computing*, *Future Generation Computer Systems*, Vol. 28, No. 5, 755-768.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1310-202409-I_PDF-E/raw.md b/marked/L/T-REC-L.1310-202409-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..afa3cec368e2bdf213601c83a3276f57846ce4c1
--- /dev/null
+++ b/marked/L/T-REC-L.1310-202409-I_PDF-E/raw.md
@@ -0,0 +1,1309 @@
+
+
+# Recommendation
+
+## **ITU-T L.1310 (09/2024)**
+
+SERIES L: Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant
+
+Energy efficiency, smart energy and green data centres
+
+# --- **Energy efficiency metrics and measurement methods for telecommunication equipment**
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with white lines representing latitude and longitude, and the letters 'ITU' in a bold, blue, sans-serif font overlaid on the globe.
+
+ITU logo
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+## **Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant**
+
+| | |
+|---------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | L.100-L.199 |
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+| OPTICAL INFRASTRUCTURES | L.200-L.299 |
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+| MAINTENANCE AND OPERATION | L.300-L.399 |
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000-L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200-L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300-L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400-L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500-L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600-L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700-L.1799 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.1310
+
+# Energy efficiency metrics and measurement methods for telecommunication equipment
+
+## Summary
+
+Recommendation ITU-T L.1310 specifies the energy efficiency metrics test procedures, methodologies and measurement profiles required to assess the energy efficiency of telecommunication equipment.
+
+Energy efficiency metrics and measurement methods are defined for telecommunication network equipment and small networking equipment.
+
+These metrics allow for the comparison of equipment within the same class, i.e., equipment using the same technologies.
+
+The comparison of equipment in different classes is out of the scope of this Recommendation.
+
+## History\*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T L.1310 | 2012-11-06 | 5 | 11.1002/1000/11639 |
+| 2.0 | ITU-T L.1310 | 2014-08-22 | 5 | 11.1002/1000/12205 |
+| 3.0 | ITU-T L.1310 | 2017-07-29 | 5 | 11.1002/1000/13284 |
+| 4.0 | ITU-T L.1310 | 2020-09-22 | 5 | 11.1002/1000/14302 |
+| 5.0 | ITU-T L.1310 | 2024-09-22 | 5 | 11.1002/1000/16009 |
+
+## Keywords
+
+Base station, energy efficiency, fixed broadband, routers.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2025
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+###### Page
+
+| | | |
+|------|---------------------------------------------------------------------------------------|----|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| 3.1 | Terms defined elsewhere ..... | 2 |
+| 3.2 | Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 4 |
+| 6 | Energy efficiency metrics definitions ..... | 4 |
+| 6.1 | General ..... | 4 |
+| 6.2 | Energy efficiency hierarchy ..... | 5 |
+| 6.3 | Load-proportional efficiency ..... | 5 |
+| 6.4 | Metrics robustness ..... | 5 |
+| 6.5 | Metrics and equipment modularity..... | 6 |
+| 7 | General test methodology ..... | 6 |
+| 7.1 | Environmental conditions..... | 6 |
+| 7.2 | Electrical conditions ..... | 6 |
+| 7.3 | Metrology requirements ..... | 6 |
+| 8 | Reporting format..... | 7 |
+| 9 | DSLAM, MSAM GPON and GEPON equipment ..... | 7 |
+| 9.1 | Metrics for DSLAM, MSAM GPON and GEPON equipment ..... | 7 |
+| 9.2 | Equipment test methodologies for broadband access technologies ..... | 8 |
+| 10 | Wireless access technologies ..... | 9 |
+| 10.1 | Metrics for wireless access technologies..... | 9 |
+| 10.2 | Tests methodologies for wireless access technologies..... | 10 |
+| 11 | Routers and Ethernet switches..... | 11 |
+| 11.1 | Metrics for routers and Ethernet switches ..... | 11 |
+| 11.2 | Tests methodologies for routers and packet switches (Ethernet, MPLS, etc.) ..... | 12 |
+| 12 | Energy efficiency metrics for small networking devices ..... | 12 |
+| 12.1 | Metrics for small networking devices ..... | 12 |
+| 12.2 | Test methodologies for small networking devices ..... | 13 |
+| 13 | WDM/TDM/optical transport network (OTN) transport multiplexers (MUXes)/switches ..... | 13 |
+| 13.1 | Metrics for WDM/TDM/OTN transport MUXes/switches ..... | 13 |
+| 13.2 | Test methodologies for WDM/TDM/OTN transport MUXes/switches..... | 14 |
+| 14 | Converged packet optical equipment ..... | 14 |
+| 14.1 | Metrics for converged packet optical equipment ..... | 14 |
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------------------------------------------------|-------------|
+| 14.2 Test methodologies for converged packet optical equipment ..... | 14 |
+| Annex A – Metrics and measurement methodologies for converged packet optical equipment with both packet signal and TDM signal functions ..... | 15 |
+| A.1 Equipment definition ..... | 15 |
+| A.2 Energy efficiency metrics..... | 17 |
+| A.3 Measurement methodology ..... | 18 |
+| Annex B – Metrics and measurement methodologies for converged packet optical equipment with packet signal, TDM signal and WDM signal functions ..... | 20 |
+| B.1 Equipment definition ..... | 20 |
+| B.2 Energy efficiency metrics..... | 20 |
+| B.3 Measurement methodology ..... | 23 |
+| Appendix I – Alternative metrics for wireline access technologies..... | 26 |
+| I.1 DSLAM and MSAN network equipment..... | 26 |
+| I.2 GPON OLT network equipment ..... | 27 |
+| I.3 GEPON OLT network equipment ..... | 27 |
+| Appendix II – Alternative metrics for routers and switches ..... | 28 |
+| II.1 Routers and switches supporting sleep (standby) mode..... | 28 |
+| II.2 Measurement methodology ..... | 29 |
+| II.3 Routers and switches supporting explicit power states ..... | 29 |
+| Bibliography..... | 30 |
+
+# Introduction
+
+In general, energy efficiency is defined as the ratio of two different energy consumption values bearing the same functional unit, i.e., the ratio of useful work (energy) to total work (energy). This definition is not easily applicable to a telecommunication system, as it does not consider the telecommunication performance of the equipment being measured.
+
+Therefore, for the purposes of this Recommendation, energy efficiency will be defined as the relationship between the specific functional unit for a piece of equipment (i.e., the useful work of telecommunications) and the energy consumption of that equipment. For example, when transmission time and frequency bandwidth are fixed, a telecommunication system that can transport more data (in bits) with less energy (in joules) is considered to be more energy efficient.
+
+For this reason, metrics that can evaluate the performance of a piece of equipment against its energy consumption are to be defined.
+
+
+
+## Energy efficiency metrics and measurement methods for telecommunication equipment
+
+# 1 Scope
+
+This Recommendation specifies the principles and concepts of energy efficiency metrics and measurement methods for telecommunication network equipment.
+
+This Recommendation also specifies the principles and concepts of energy efficiency metrics and measurement methods for small networking equipment used in the home and small enterprise locations.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ATIS-0600015.02.2016] ATIS-0600015.02.2016, *Energy Efficiency for Telecommunication Equipment: Methodology for Measurement and Reporting – Transport & Optical Access Requirements.*
+- [ATIS-0600015.03.2023] ATIS-0600015.03.2023, *Energy Efficiency for Telecommunication Equipment: Methodology for Measurement and Reporting for Router and Ethernet Switch Products.*
+- [ETSI EN 303 215] ETSI EN 303 215 V1.3.1 (2015), *Environmental Engineering (EE); Measurement methods and limits for power consumption in broadband telecommunication networks equipment.*
+- [ETSI ES 202 706-1] ETSI ES 202 706-1 V1.7.1 (2022), *Environmental Engineering (EE); Metrics and measurement method for energy efficiency of wireless access network equipment; Part 1: Power consumption – static measurement method.*
+- [ETSI TS 102 706-2] ETSI TS 102 706-2 V1.7.1 (2024) *Environmental Engineering (EE); Metrics and Measurement Method for Energy Efficiency of Wireless Access Network Equipment; Part 2: Energy Efficiency – dynamic measurement method.*
+- [ETSI TS 103 786] ETSI TS 103 786 V1.3.1 (2024) *Environmental Engineering (EE); Measurement method for energy efficiency of wireless access network equipment; Dynamic energy efficiency measurement method of 5G Base Station (BS)*
+- [ISO 14040] ISO 14040:2006, *Environmental management – Life cycle assessment – Principles and framework.*
+- [ISO/IEC 17025] ISO/IEC 17025:2017, *General requirements for the competence of testing and calibration laboratories.*
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 active mode:** For small networking equipment, this is the operational mode where all ports (wireless access network (WAN) and local area network (LAN)) are connected, with at least one Wi-Fi connection, if a Wi-Fi function is available.
+
+**3.2.2 energy:** The capacity for doing work.
+
+**3.2.3 energy efficiency rating:** Functional unit divided by the energy used.
+
+NOTE – For more details on energy efficiency for telecommunication equipment, see [b-ITU-T L.1315].
+
+**3.2.4 functional unit** (based on [ISO 14040]): A performance representation of the system under analysis.
+
+**3.2.5 idle mode:** The state of a network element not handling any user data traffic, but ready to do so.
+
+NOTE – It is not zero traffic, as service and protocol supporting traffic are present.
+
+**3.2.6 low power (sleep) mode:** For small networking equipment, this means a state that happens after the device detects no user activity for a certain period of time and reduces energy consumption.
+
+NOTE – For this state, no user-facing local area network (LAN) ports are connected; the Wi-Fi is active but no clients are connected. The wide area network (WAN) port may be inactive. The device will reactivate on detecting a connection from a user port or device.
+
+**3.2.7 non-drop rate (NDR) throughput:** The observed system throughput at which no packet drops are recorded.
+
+**3.2.8 small networking device:** A networking device with fixed hardware configuration, designed for home/domestic or small office use, with fewer than 12 ports.
+
+NOTE – This device can have wireless functionality implemented. Wireless functionality is not considered a port.
+
+**3.2.9 system throughput:** The sum of throughput on all system ports in the egress direction (bit/s). Example: Maximum throughput for 1 Gb Ethernet is 1 Gbit/s.
+
+**3.2.10 useful output:** The useful work carried out by the equipment, e.g., delivered bits or output energy from wireless equipment.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+AC Alternating Current
+
+ADSL2+ Asymmetric Digital Subscriber Line 2 Transceiver Extended Bandwidth
+
+AMP Amplifier
+
+BSC Base Station Controller
+
+BTS Base Transceiver Station
+
+CDMA Code Division Multiple Access
+
+CPU Central Processing Unit
+
+| | |
+|--------|--------------------------------------------|
+| DC | Direct Current |
+| DMUX | Demultiplexer |
+| DSLAM | Digital Subscriber Line Access Multiplexer |
+| EDGE | Enhanced Data for GSM Evolution |
+| EER | Energy Efficiency Rating |
+| EUT | Equipment Under Test |
+| GEAPON | Gigabit Ethernet Passive Optical Network |
+| GPON | Gigabit Passive Optical Network |
+| GSM | Global System for Mobile Communications |
+| HSPA | High Speed Packet Access |
+| IF | Interface |
+| IMIX | Internet MIX Traffic |
+| KPI | Key Performance Indicator |
+| LAN | Local Area Network |
+| LTE | Long Term Evolution |
+| MAC | Media Access Control |
+| MPLS | Multiprotocol Label Switching |
+| MSAN | Multiservice Access Node |
+| MUX | Multiplexer |
+| NNI | Network-Network Interface |
+| NR | New Radio |
+| NDR | Non-Drop Rate |
+| OADM | Optical Add-Drop Multiplexer |
+| OC | Optical Carrier |
+| OLT | Optical Line Termination |
+| ONT | Optical Network Termination |
+| ONU | Optical Network Unit |
+| OSI | Open Systems Interconnection |
+| OTN | Optical Transport Network |
+| OTU | Optical Transport Unit |
+| OXC | Optical Cross Connect |
+| P2P | Point-to-Point |
+| PF | Power Factor |
+| PON | Passive Optical Network |
+| PONIF | Passive Optical Network Interface |
+| POTS | Plain Old Telephone Service |
+| PSU | Power Supply Unit |
+
+| | |
+|-------|---------------------------------------------|
+| RBS | Radio Base Station |
+| RF | Radio Frequency |
+| RFU | Radio Frequency Unit |
+| RNC | Radio Network Controller |
+| ROADM | Reconfigurable Optical Add-Drop Multiplexer |
+| SDH | Synchronous Digital Hierarchy |
+| SONET | Synchronous Optical Network |
+| STM | Synchronous Transport Module |
+| SW | Switch |
+| TDM | Time Division Multiplex |
+| TEER | Telecommunications Energy Efficiency Ratio |
+| UE | User Equipment |
+| UUT | Unit Under Test |
+| UNI | User Network Interface |
+| UMTS | Universal Mobile Telecommunication System |
+| VDSL2 | Very high bit rate Digital Subscriber Line |
+| VLAN | Virtual Local Area Network |
+| WAN | Wide Area Network |
+| WCDMA | Wideband Code Division Multiple Access |
+| WDM | Wavelength Division Multiplexing |
+
+# 5 Conventions
+
+In this Recommendation, the term "energy consumption" is used to describe the transformation of input energy into the functional unit and waste within telecommunication systems.
+
+For all practical purposes, it is assumed that telecommunication system devices act as single entities, with metrics estimating the total efficiency of input energy within the entire telecommunication device.
+
+In this Recommendation, the term "energy efficiency" is used to describe the ability of a telecommunication system to minimize energy waste, although "power efficiency" could also have been used for the same purpose.
+
+# 6 Energy efficiency metrics definitions
+
+## 6.1 General
+
+The energy efficiency metric is typically defined as the ratio between the functional unit and the energy necessary to deliver the functional unit; the higher the value of the metric, the greater the efficiency of the equipment.
+
+The inverse metric, energy divided by the functional unit, could be used as an alternative.
+
+The following clauses contain detailed metric definitions and test methodologies for various telecommunication equipment.
+
+The energy efficiency rating (EER) is a metric generally defined as a functional unit divided by the energy used. Various types of equipment have their own EER definitions.
+
+## **6.2 Energy efficiency hierarchy**
+
+An energy efficiency metric can be defined at the network level, the system level, the equipment level and the component level. In this Recommendation, only metrics at the system and equipment levels are considered as mandatory. Metrics at the component level are given as suggestions only and are not mandatory.
+
+### **6.2.1 Energy efficiency at the network level**
+
+Network level metrics are used to evaluate the energy efficiency of an entire network or part of it (e.g., the access network of an operator). They are normally used to evaluate a network for internal operator use or to satisfy an environmental assessment. For this Recommendation, the network level is considered a metric that will cover not only one single product but also a telecommunication network composed of different interworking equipment.
+
+### **6.2.2 Energy efficiency at the equipment and system levels**
+
+Equipment and system level metrics are mostly used to compare telecommunication equipment of the same technology and similar configuration. They evaluate the overall energy efficiency performance at the equipment and system levels, which are considered as a "single box" or "single entity", from the measurement point of view.
+
+### **6.2.3 Energy efficiency at the component level**
+
+Component-level metrics can be used in the design, development and manufacture of energy efficient equipment. They regard equipment as an "open box" and evaluate the energy efficiency performance of its individual components. Measuring and understanding the energy efficiency or energy consumption of each component within the equipment helps to identify the bottlenecks and key components in a system with regard to energy saving. It should be kept in mind that these kinds of metrics may lead to sub-optimizations unless considered in the context of the equipment's overall energy efficiency.
+
+## **6.3 Load-proportional efficiency**
+
+There are classes of telecommunication equipment (e.g., time division multiplex (TDM) switches) where the functional unit is stationary and does not change through the active-use phase.
+
+However, a vast number of telecommunication devices operate under variable-load conditions, where the measured value of a functional unit can fluctuate based on user demand.
+
+Ideally, telecommunication devices should be able to reduce their energy consumption in proportion to the useful output produced. However, this goal presents different challenges and opportunities in recognizing and responding to low utilization periods.
+
+In order to capture such capabilities, where available, this Recommendation defines the EER as a weighted, load-proportional metric.
+
+## **6.4 Metrics robustness**
+
+To allow reliable equipment comparisons based on metrics, the metric values should be obtained in strict accordance with ITU-T documentation and the referenced standardization documents.
+
+Whenever the complete application of this Recommendation is not possible for technological reasons (e.g., new technologies may not be covered or may make measurement implementation difficult), manufacturers can use another metric that should be clearly documented.
+
+## 6.5 Metrics and equipment modularity
+
+Telecommunication equipment is commonly available in both fixed and modular form factors. In the latter case, telecommunication equipment can be configured in various ways, which may affect its efficiency ratings. Throughout this Recommendation, the following approach to modularity is recommended:
+
+- Metrics for modular telecommunication systems shall be obtained using the most common set-up and configurations. The metrics shall be reported along with the telecommunication equipment configuration used.
+- Metrics for other telecommunication equipment configurations can be obtained by using metrics obtained from partial configurations. This methodology is described in the relevant measurement procedures. (For example, in [ATIS-0600015.02.2016] this is called the "modular method", and in [ETSI EN 303 215] it is called the "alternative method").
+
+# 7 General test methodology
+
+## 7.1 Environmental conditions
+
+### 7.1.1 Temperature
+
+The equipment should be evaluated at an ambient temperature of $25 \pm 3$ °C. The equipment itself should stay online or operate at this air temperature for not less than three hours prior to the test. No ambient temperature changes are allowed until the test is complete.
+
+For some types of equipment, additional measurements are required to test the energy efficiency at higher/lower temperatures, as reported in the detailed equipment-specific requirement.
+
+### 7.1.2 Humidity
+
+The equipment should be evaluated at a relative humidity of 30% to 75%.
+
+### 7.1.3 Air pressure
+
+The equipment should be evaluated at a site pressure between 812 to 1 060 hPa. No targeted airflows are allowed except for regular ambient room, data centre or rack cooling.
+
+## 7.2 Electrical conditions
+
+### 7.2.1 Direct current (DC) voltage
+
+The equipment powered by $-48$ Vdc source shall be evaluated at a DC voltage of $-53$ V $\pm 2$ V.
+
+Equipment using nominal DC voltages other than $-48$ Vdc shall be evaluated at $\pm 4\%$ of the specified float voltage.
+
+### 7.2.2 Alternating current (AC) voltage and frequency
+
+The input to the equipment (all active feeds) should be the nominal specified voltage $\pm 5\%$ and the specified frequency $\pm 1\%$ . If the equipment can work at different nominal voltages, the measurement shall be executed at one of the specified nominal voltages.
+
+An external AC/DC adapter is considered an integral part of the equipment.
+
+NOTE – ITU-T is developing Recommendations on AC/DC adapters; the AC/DC adapter should be in line with these Recommendations if applicable.
+
+## 7.3 Metrology requirements
+
+Every active power feed should have the power (current) meter installed in the power line with a desired accuracy of not less than $\pm 1\%$ of the actual power level. The power meter should include
+
+correction for the power factor (PF) on AC feeds; otherwise, it will be necessary to also record the PF in the measurement report. All energy consumption calculations are based on averaging multiple readings over the course of measurements. Power meters should be able to produce no fewer than 100 evenly spaced readings in every full test cycle duration.
+
+All measurement instruments used should be calibrated according to [ISO/IEC 17025], be within the calibration due date, and the measurement tolerance must be within $\pm 1\%$ :
+
+- Power sources used to provide power to the EUT shall be capable of providing a minimum of 1.5 times the power rating of the EUT.
+- Power measurement instruments (such as voltmeters and ampere meters or power analysers) shall have a resolution of 0.5% or better. AC power measurement instruments shall have the following minimum characteristics:
+ - i) a minimum digitizing sample rate of 40 kHz;
+ - ii) input circuitry with a minimum bandwidth of 80 kHz;
+ - iii) capability of accurate readings of waveforms having a crest factor of up to at least 5;
+ - iv) power factor correction and reporting.
+
+# 8 Reporting format
+
+This Recommendation does not preclude any specific reporting formats. The general requirements for test reports are contained in [ISO/IEC 17025].
+
+However, any results that are collected under this methodology are intended to be reproducible. For this reason, the minimum set of information (beyond the actual set of measurements) reported should include the following documentation:
+
+- All equipment software versions, hardware board revisions and device configurations used during the test. All commands applied to equipment for the purposes of static reconfiguration or run-time queries performed during the test should be disclosed.
+- Traffic generator/measurement tool, actual voltage in power feeds and ambient (environmental) conditions at test site.
+- The test set-up should be fully described, including topology, the choice of offered load structure, and test actions within a range of possible choices.
+
+# 9 DSLAM, MSAM GPON and GEPON equipment
+
+## 9.1 Metrics for DSLAM, MSAM GPON and GEPON equipment
+
+This clause defines the equipment level metrics for digital subscriber line access multiplexer (DSLAM), multiservice access node (MSAN), gigabit passive optical network (GPON) and gigabit Ethernet passive optical network (GEPON) equipment. In particular, this clause covers:
+
+- DSLAM equipment;
+- MSAN equipment;
+- GPON and GEPON optical line termination (OLT) equipment.
+
+For these equipment typologies, the most commonly used metric is the $P_{\text{port}}$ , which considers the number of ports at a fixed load as a functional unit.
+
+Such a metric is assumed to refer to a fully equipped configuration, taking into account the line cards with the same technology (e.g., all asymmetric digital subscriber line 2 transceiver extended bandwidth (ADSL2+) cards, all very high bit rate digital subscriber line (VDSL2) cards, all GPON cards, and all plain old telephone service (POTS) cards). Moreover, such line cards must refer to the same profile/state.
+
+Equipment with line cards working at different profiles/states shall be characterized with different metric values for each specific profile/state.
+
+$$P_{\text{port}} = P_{\text{EQ}} / N_{\text{ports}} \text{ [W/port]} \quad (9-1)$$
+
+where:
+
+$P_{\text{EQ}}$ is the power (in Watts) of fully equipped wireline network equipment with all its line cards working in a specific profile/state (e.g., all VDSL2 subscriber lines in L0 state and all ADSL2+ subscriber lines in L2 state).
+
+$N_{\text{ports}}$ is the maximum number of ports served by the broadband network's EUT.
+
+## 9.2 Equipment test methodologies for broadband access technologies
+
+This clause defines measurement procedures for broadband fixed access technologies.
+
+### 9.2.1 DSLAM and MSAN network equipment
+
+For test methodologies, equipment configuration and set-up, the methodology reported in clause 5.2 of [ETSI EN 303 215] shall apply, with the modification of the general measurement conditions presented in clause 7 of this Recommendation.
+
+### 9.2.2 GPON OLT network equipment
+
+For test methodologies, equipment configuration and set-up, the methodology reported in clause 5.2 of [ETSI EN 303 215] shall apply, with the modification of the general measurement conditions presented in clause 7 of this Recommendation.
+
+### 9.2.3 GEPON OLT network equipment
+
+For OLT, 1 Gbit/s for both the network-network interface (NNI) side and the passive optical network (PON) side is used, and the following three settings for the load factor:
+
+- 1) 100% load factor: a state where 64-byte frames flow continuously (without interruption).
+- 2) 50% load factor: the state where 512-byte frames flow 50% of the time.
+- 3) 0% load factor: the state where frames are not flowing.
+
+Furthermore, in stipulating the load factor, the load factor specified by the data entry side shall be used (NNI or user network interface (UNI)), as seen in Figure 9-1.
+
+
+
+The diagram illustrates the internal architecture and external interfaces of a GEPON OLT. The OLT unit contains multiple PON interfaces (PONIF 1, PONIF 2, ..., PONIF n) and a central processing unit (CPU). The CPU is connected to external control equipment. On the Network-Network Interface (NNI) side, multiple 1G connections are shown. On the Passive Optical Network (PON) side, a PONIF connects to multiple Optical Network Units (ONUs), each with a 1G connection. The ONUs have User Network Interface (UNI) ports. The OLT is powered by System-0 and System-1, which are connected to a power meter, which in turn is connected to an AC power supply (DC power supply). A label 'L.1310(17)\_F9-1' is present in the bottom right corner.
+
+Diagram of GEPON OLT equipment showing internal components and external connections. The OLT box contains PONIF 1, PONIF 2, ..., PONIF n, and a CPU. The CPU is connected to 'any control equipment'. The OLT has an NNI side on the left with multiple 1G connections. The PON side on the right has a PONIF connected to multiple ONUs, each with a 1G connection to the PONIF. The ONUs have UNI ports. Below the OLT, System-0 and System-1 are connected to a Power meter, which is connected to an AC power supply (DC power supply).
+
+Figure 9-1 – Description of GEPON OLT equipment
+
+$$P_{EQ} = (\text{power at } 100\% \text{ load} + \text{power at } 50\% \text{ load} + \text{power at } 0\% \text{ load}) / 3 \quad (9-2)$$
+
+# 10 Wireless access technologies
+
+Wireless access technologies cover the following radio access technologies: global system for mobile communications (GSM)/enhanced data for GSM evolution (EDGE), code division multiple access (CDMA), wideband CDMA (WCDMA), long term evolution (LTE) and new radio (NR).
+
+A wireless access network consists of more than one element (a radio base station (RBS), a controller, etc.)
+
+An RBS is a network component that serves one or more sectors and has radio frequency (RF) interfaces to mobile stations through the air interface, and metallic or optical interfaces to a wireless network infrastructure (base station controller (BSC), radio network controller (RNC) or mobility management entity). Within this Recommendation, an RBS can be a base transceiver station (BTS) (for GSM/EDGE and cdma2000), a NodeB (for WCDMA/high speed packet access (HSPA)), an eNodeB (for LTE), or a gNodeB (for NR). The controller functionality within an RBS has interfaces to the core network or core network simulator.
+
+As the RBS energy consumption is the dominant part of the total energy consumption of a wireless access network, this Recommendation covers how to calculate RBS energy efficiency.
+
+However, since the functionalities located externally to the RBS in the core network can affect the RBS power and "useful unit", these functionalities have also been taken into account.
+
+Low, medium and high load modes have been defined for the RBS usage profile. Idle mode and max load cases have been omitted intentionally for the following reasons:
+
+- Idle mode is a state rarely used in a practical radio network. An RBS transmits, as a minimum, a pilot and broadcast channels.
+- Max load is typically avoided by network design. It might occur on exceptional events a few times a year. If peak load is reached repeatedly, an operator will do a capacity upgrade.
+- Testing of additional modes will increase complexity and testing time without providing significant additional information, and will have a low impact on the average power consumption.
+
+## 10.1 Metrics for wireless access technologies
+
+### 10.1.1 Metric for wireless access equipment power/energy consumption
+
+- Power and energy consumption metric for GSM, universal mobile telecommunication system (UMTS), LTE and NR RBS at static load is defined in [ETSI ES 202 706-1].
+- Power and energy consumption metric for LTE RBS and NR RBS at dynamic load is defined in [ETSI TS 102 706-2] and [ETSI TS 103 786], respectively.
+
+### 10.1.2 Metric for wireless access equipment RF energy efficiency
+
+The proposed energy efficiency metric at RF unit level is:
+
+$$EE_{RFU} = E_{output} / E_{RFU} \quad (10-1)$$
+
+where:
+
+$E_{output}$ is daily RF output energy consumption [Wh] under different loads
+
+$E_{RFU}$ is daily RF units energy consumption [Wh] under different loads.
+
+$E_{output}$ and $E_{RFU}$ are defined as:
+
+$$E_{output} = P_{BH, output} \times t_{BH} + P_{med, output} \times t_{med} + P_{low, output} \times t_{low} \quad (10-2)$$
+
+$$E_{\text{RFU}} = P_{\text{BH, RFU}} \times t_{\text{BH}} + P_{\text{med, RFU}} \times t_{\text{med}} + P_{\text{low, RFU}} \times t_{\text{low}} \quad (10-3)$$
+
+In which $P_{\text{BH, output}}$ , $P_{\text{med, output}}$ and $P_{\text{low, output}}$ [W] are RF output power under three different load levels, defined for static scenario in [ETSI ES 202 706-1] and for dynamic scenario in [ETSI TS 102 706-2] and [ETSI TS 103 786]; $P_{\text{BH, RFU}}$ , $P_{\text{med, RFU}}$ and $P_{\text{low, RFU}}$ [W] are the power consumption of RF units under three different load levels; $t_{\text{BH}}$ , $t_{\text{med}}$ and $t_{\text{low}}$ [hour] are durations of different load levels during a day. The metric for static scenario is applicable to GSM, UMTS, LTE and NR, and for dynamic scenario to LTE and NR.
+
+### 10.1.3 Metrics for wireless access equipment dynamic energy efficiency
+
+Energy efficiency metrics for RBS under different dynamic loads (low load, medium load and busy-hour load) are defined in [ETSI TS 102 706-2] for LTE RBS and in [ETSI TS 103 786] for NR RBS. In these specifications, the energy efficiency of an RBS consists of the ratio between the work done in terms of the total number of bits delivered to all connected user equipment (UE) and the consumed energy for delivering these bits. The key performance indicator (KPI) presented in this specification is energy efficiency in [bits/Wh].
+
+## 10.2 Tests methodologies for wireless access technologies
+
+For test methodologies, equipment configuration and set-up, the following standards shall apply, with the modification of the general measurement conditions presented in clause 7.
+
+- [ETSI ES 202 706-1] for GSM, UMTS, LTE and NR RBS power consumption and RF output power at static load, with modifications according to clause 10.2.2.
+- [ETSI TS 102 706-2] for LTE RBS energy consumption and energy efficiency at dynamic traffic load.
+- [ETSI TS 103 786] for NR RBS energy consumption and energy efficiency at dynamic traffic load.
+
+### 10.2.1 Test methodologies for wireless access equipment power consumption and energy efficiency
+
+All metrics and measurement methods for static and dynamic measurement methods are described in [ETSI ES 202 706-1], [ETSI TS 102 706-2], and [ETSI TS 103 786].
+
+### 10.2.2 Test methodologies for wireless access equipment RF energy efficiency
+
+Test set-up, RBS configurations, RBS power consumption measurements, RF output power measurements, measurement conditions and load models of RBS and RF output power measurement are described in [ETSI ES 202 706-1], [ETSI TS 102 706-2] and [ETSI TS 103 786].
+
+For measurement of RF units power consumption $P_{\text{RFU}}$ , the measurement interface is shown in Figure 10-1 for clarification.
+
+
+
+The diagram illustrates the measurement interface for RF unit power consumption. A 'Power supply' block is connected to an 'RF unit' block. The input power to the power supply is labeled $P_i$ . The output power of the power supply, which enters the RF unit, is labeled $P_{\text{RFU}}$ . The RF unit has an 'Antenna connector' on its right side. This connector is linked to an 'RF coupler' block. The RF coupler has two output paths: one leading to an 'RF power meter' block and another leading to an 'RF terminator' block. Dashed lines indicate the measurement interfaces for the RF unit, the RF coupler, and the RF power meter.
+
+Figure 10-1 – Measurement interfaces. The diagram shows a power supply connected to an RF unit. The RF unit is connected to an antenna connector. The antenna connector is connected to an RF coupler. The RF coupler is connected to an RF power meter and an RF terminator. The power supply is labeled P\_i and the RF unit is labeled P\_RFU. The diagram is labeled L.1310(20)\_F10-1.
+
+Figure 10-1 – Measurement interfaces
+
+# 11 Routers and Ethernet switches
+
+## 11.1 Metrics for routers and Ethernet switches
+
+The metrics adopted for routers and switches depend on the total throughput of the equipment. (See [ATIS-0600015.03.2023] for an explanation of the total throughput, testing topologies and traffic patterns.)
+
+This clause addresses equipment that is categorized as enterprise, service provider and branch office routers, and Ethernet switch equipment.
+
+The proposed metric is:
+
+$$\text{EER} = T_i / P_w \quad [\text{Mbit/s/W}] \quad (11-1)$$
+
+where:
+
+$T_i$ is NDR throughput
+
+$P_w$ is weighted power (energy consumption rate)
+
+$$P_w = a \times P_{u1} + b \times P_{u2} + c \times P_{u3} \quad (11-2)$$
+
+where:
+
+$(a, b, c)$ = relative weights for utilization levels, where $a + b + c = 1$ ; see Tables 11-1 and 11-2
+
+$(P_{u1}, P_{u2}, P_{u3})$ = power measured at respective utilization levels.
+
+**Table 11-1 – Class definitions, EER calculation parameters and load profiles for routing equipment**
+
+| Class | Representative utilization | % of utilization for energy measurements, u1, u2, u3 | Weight multipliers a, b, c | Traffic profile simple IMIX |
+|---------------|----------------------------|------------------------------------------------------|----------------------------|-----------------------------|
+| Access router | 1%-3% | 0, 10, 100 | $a=0.1, b=0.8, c=0.1$ | (IPv4) |
+| Edge router | 3%-6% | 0, 10, 100 | $a=0.1, b=0.8, c=0.1$ | IPv4/6/MPLS |
+| Core router | 20%-30% | 0, 30, 100 | $a=0.1, b=0.8, c=0.1$ | IPv4/6/MPLS |
+
+**Table 11-2 – Class definitions, EER calculation parameters and load profiles for Ethernet switching equipment**
+
+| Class | Representative utilization | % of utilization for energy measurements, u1, u2, u3 | Weight multipliers a, b, c | Traffic profile simple IMIX, unicast |
+|--------------------------|----------------------------|------------------------------------------------------|----------------------------|--------------------------------------|
+| Access | 1%-3% | 0, 10, 100 | $a=0.1, b=0.8, c=0.1$ | Ethernet |
+| High speed access | 5%-8% | 0, 10, 100 | $a=0.1, b=0.8, c=0.1$ | Ethernet |
+| Distribution/aggregation | 10%-15% | 0, 10, 100 | $a=0.1, b=0.8, c=0.1$ | Ethernet |
+| Core | 15%-20% | 0, 30, 100 | $a=0.1, b=0.8, c=0.1$ | Ethernet |
+| Data centre | 12%-18% | 0, 30, 100 | $a=0.1, b=0.8, c=0.1$ | Ethernet |
+
+The complete methodology for testing is presented in [ATIS-0600015.03.2023]. The weight multipliers $a$ , $b$ , $c$ are established by [ATIS-0600015.03.2023], considering the average traffic distribution during a day.
+
+## 11.2 Tests methodologies for routers and packet switches (Ethernet, MPLS, etc.)
+
+For test methodologies, equipment configuration and set-up, the methodology reported in [ATIS-0600015.03.2023] shall apply, with the modification of the general measurement conditions presented in clause 7.
+
+For EUT with 40 GBs and higher speed ports, it is permitted to use vertical "snake"/cascade topology, with one port on each line card used for mesh traffic, as shown in Figure 11-1. Use throughput numbers on meshed ports for total system throughput calculation.
+
+
+
+The diagram illustrates a network topology for testing. On the left, there are N cards, labeled Card 1 at the top and Card N at the bottom. Each card has M ports. Card 1's first port is labeled '1' and its M-th port is labeled 'M'. Card N's ports are also shown. White vertical lines connect ports on the same card, representing internal cross connections or VLAN "snake" connections. Black horizontal lines connect the Traffic generator on the right to one port on each card, representing mesh traffic. There are N such lines. Yellow horizontal lines connect the Traffic generator to the first port of Card 1 and the last port of Card N, representing traffic for "snaked" ports. The diagram is labeled "N cards with M ports each" at the top, "N lines for full mesh traffic" in the center, and "L.1310(17)\_F11-1" at the bottom right.
+
+Diagram of a 'vertical' snake topology with partial mesh traffic. It shows N cards (Card 1 to Card N) with M ports each. Card 1 has port 1 connected to a Traffic generator. Card N has port M connected to the same Traffic generator. White lines show internal cross connections between ports on the same card. Black lines show mesh traffic connections between the Traffic generator and one port on each card. Yellow lines show traffic for 'snaked' ports from the Traffic generator to Card 1 and Card N. The diagram is labeled 'N cards with M ports each', 'N lines for full mesh traffic', and 'L.1310(17)\_F11-1'.
+
+###### NOTE:
+
+- black lines show ports connected in mesh traffic, each talk to all others, total N ports;
+- white lines show internal cross connect/VLAN "snake" connected ports;
+- yellow lines provide traffic for "snaked" ports.
+
+**Figure 11-1 – Topology for "vertical" snake with partial mesh traffic**
+
+In cases of the largest generation of interfaces with very high data rate or very high port density, it may be not possible to build a set-up with complete or even partial mesh topology because of resource availability of traffic generator ports in needed numbers or speed. In that case, it is permitted to use snake traffic topology or any combination of snake/mesh on all ports to determine NDR and perform power measurements.
+
+Reported data shall be marked as declared values and contain a complete description of the methodology of testing used to obtain results.
+
+# 12 Energy efficiency metrics for small networking devices
+
+## 12.1 Metrics for small networking devices
+
+The metrics adopted for small networking devices intended for home/domestic or small office use are:
+
+$$EER = \frac{0.35T_{idle} + 0.5T_{lowpower} + 0.15T_{Maximum}}{0.35P_{idle} + 0.5P_{lowpower} + 0.15P_{Maximum}} \quad (\text{Mbit/s/W}) \quad (12-1)$$
+
+For interfaces with throughput (T) sensitive to distance, this is defined as:
+
+$$T = 0.5(T_{20\% \text{ of max distance}} + T_{80\% \text{ of max distance}}) \quad (12-2)$$
+
+**Throughput:** For small network equipment, this is the maximum non-drop data rate between (WAN and LAN ports in the ingress direction.
+
+**Line rate/speed:** For small network equipment, this is the maximum possible number of transmitted/received bits.
+
+Power shall be averaged over 5 minutes, taking measurements every 30 seconds. During idle power, IP pings shall be sent via the user interface.
+
+## 12.2 Test methodologies for small networking devices
+
+The reference methodologies to be used to measure the maximum throughput are reported in clause 6.4.1 of [ATIS-0600015.03.2023] for the "network/uplink" and "access/downlink" configurations.
+
+With reference to clause 6.5 of [ATIS-0600015.03.2023], the test methodology is as follows:
+
+### Step 1: Qualification
+
+Small network equipment shall be measured following the method described in clause 6.5.1 of [ATIS-0600015.03.2023].
+
+### Step 2: Full load
+
+Small network equipment shall be measured following the method described in clause 6.5.2 of [ATIS-0600015.03.2023].
+
+### Step 3: Utilization
+
+This step of [ATIS-0600015.03.2023] shall not be applicable to small network equipment.
+
+### Step 4: Idle load
+
+Small network equipment shall be measured following the method described in clause 6.5.3 of [ATIS-0600015.03.2023].
+
+### Step 5: Low power (sleep)
+
+Depending on the implementation, the low power (sleep) mode shall be activated. Power will be measured and recorded for a period of 15 minutes after activation of the mode; the average power will then be calculated and used in equation 12-1.
+
+The manufacturer shall declare how to activate the low power (sleep) mode, e.g., disconnect the LAN port. The activation modality will be recorded in the test report.
+
+# 13 WDM/TDM/optical transport network (OTN) transport multiplexers (MUXes)/switches
+
+## 13.1 Metrics for WDM/TDM/OTN transport MUXes/switches
+
+The metrics for transport equipment excluding microwave radio equipment are defined in [ATIS-0600015.02.2016].
+
+## **13.2 Test methodologies for WDM/TDM/OTN transport MUXes/switches**
+
+For test methodologies, equipment configuration and set-up, the methodology reported in [ATIS-0600015.02.2016] shall be applied, with the modification of the general measurement conditions presented in clause 7.
+
+# **14 Converged packet optical equipment**
+
+## **14.1 Metrics for converged packet optical equipment**
+
+The metrics for converged packet optical equipment with packet signal and TDM signal functions are defined in Annex A.
+
+The metrics for converged packet optical equipment with packet signal, TDM signal and wavelength division multiplexing (WDM) signal functions are defined in Annex B.
+
+## **14.2 Test methodologies for converged packet optical equipment**
+
+### **14.2.1 Test methodologies for converged packet optical equipment with packet signal and TDM signal functions**
+
+For test methodologies, equipment configuration and set-up, the methodology described in Annex A shall be applied, with the modification of the general measurement conditions presented in clause 7.
+
+### **14.2.2 Test methodologies for converged packet optical equipment with packet signal, TDM signal and WDM signal functions**
+
+For test methodologies, equipment configuration and set-up, the methodology described in Annex B shall be applied, with the modification of the general measurement conditions presented in clause 7.
+
+# Annex A
+
+## Metrics and measurement methodologies for converged packet optical equipment with both packet signal and TDM signal functions
+
+(This annex forms an integral part of this Recommendation.)
+
+### A.1 Equipment definition
+
+Converged packet optical equipment I refers to a type of transport equipment which transports (switches) multiple types of signals, such as packet signals and TDM signals.
+
+The definitions of these types of signals shall be as follows:
+
+**Packet signals:** Signals which include a media access control (MAC) address relayed via ISO Open Systems Interconnection (OSI) layer 2 (data link layer) or an IP address relayed via ISO OSI layer 3 (network layer) or a label with routing information.
+
+**TDM signals:** TDM signals, such as synchronous transport module (STM)-n/OC-n/optical transport unit (OTU)-n signals defined in synchronous digital hierarchy (SDH)/synchronous optical network (SONET)/OTN, as well as analogue signals conveying image or voice over telephone lines.
+
+The scope of this Recommendation shall cover the following four configuration models.
+
+**Model I:** Configuration where TDM signals and packet signals in both directions are switched independently
+
+**Model II:** Configuration where some TDM signals are converted into packets and switched via the packet switch, or some packet signals are de-packeted and switched via the TDM switch (see Figure A.2).
+
+**Model III:** Configuration where all TDM signals are converted into packet signals and switched via the packet switch (see Figure A.3).
+
+**Model IV:** Configuration where all packet signals are de-packeted and switched via the TDM switch (see Figure A.4).
+
+
+
+The diagram illustrates the internal architecture of Converged packet optical equipment I (Model I). A central green rectangular block labeled 'SW' (Switch) contains two vertically stacked sub-blocks: an orange 'TDM SW' (TDM Switch) and a yellow 'Packet SW' (Packet Switch). Above the 'SW' block is a blue 'Clock' block, connected to both the 'TDM SW' and 'Packet SW' by dashed grey arrows. Below the 'SW' block is a blue 'Monitor/control' block. On the left side, there are two input blocks: a grey 'TDM IF' (TDM Interface) and a yellow 'Packet IF' (Packet Interface). Red arrows indicate signal flow from the 'TDM IF' to the 'TDM SW' and from the 'Packet IF' to the 'Packet SW'. On the right side, red arrows indicate signal flow from the 'TDM SW' to the 'TDM IF' and from the 'Packet SW' to the 'Packet IF'. Blue arrows point into the 'TDM IF' and 'Packet IF' blocks from the left, and blue arrows point out of these blocks to the right. The entire diagram is enclosed in a yellow rectangular frame.
+
+Diagram of Converged packet optical equipment I configuration (model I). The diagram shows a central green box labeled 'SW' containing two sub-boxes: 'TDM SW' and 'Packet SW'. Above the 'SW' box is a 'Clock' box with dashed lines connecting it to the 'TDM SW' and 'Packet SW'. Below the 'SW' box is a 'Monitor/control' box. On the left, there are two input boxes: 'TDM IF' and 'Packet IF'. Red arrows point from 'TDM IF' to 'TDM SW' and from 'Packet IF' to 'Packet SW'. On the right, red arrows point from 'TDM SW' to 'TDM IF' and from 'Packet SW' to 'Packet IF'. Blue arrows point into the 'TDM IF' and 'Packet IF' boxes from the left, and blue arrows point out of the 'TDM IF' and 'Packet IF' boxes to the right. The entire diagram is set against a yellow background.
+
+L.1310(14)\_FA.1
+
+Figure A.1 – Converged packet optical equipment I configuration (model I)
+
+
+
+This block diagram illustrates the internal architecture of converged packet optical equipment I configuration (model II). At the center is a green 'SW' (Switch) block containing two sub-components: an orange 'TDM SW' and a yellow 'Packet SW'. A blue 'Clock' block at the top provides timing signals to both switches via dashed grey arrows. Below the switches is a blue 'Monitor/control' block. The equipment has four external interfaces on the left and four on the right. On the left, from top to bottom: a 'TDM IF' (grey) connected directly to the 'TDM SW'; a 'Packet IF' (yellow) connected to 'Depacket Processing' (pink) which then connects to the 'TDM SW'; another 'TDM IF' (grey) connected to 'Packet Processing' (pink) which connects to the 'Packet SW'; and a 'Packet IF' (yellow) connected directly to the 'Packet SW'. On the right, from top to bottom: a 'Packet IF' (yellow) connected to 'Packet Processing' (pink) which connects to the 'TDM SW'; a 'TDM IF' (grey) connected directly to the 'TDM SW'; a 'Packet IF' (yellow) connected directly to the 'Packet SW'; and a 'Packet IF' (yellow) connected to 'Depacket Processing' (pink) which then connects to the 'TDM SW'. All external connections are shown with red arrows.
+
+L.1310(14)\_FA.2
+
+Figure A.2: Converged packet optical equipment I configuration (model II).
+
+**Figure A.2 – Converged packet optical equipment I configuration (model II)**
+
+
+
+This block diagram illustrates the internal architecture of converged packet optical equipment I configuration (model III). At the center is a green 'SW' (Switch) block containing a single yellow 'Packet SW' component. A blue 'Clock' block at the top provides timing signals to the switch via a dashed grey arrow. Below the switch is a blue 'Monitor/control' block. The equipment has two external interfaces on the left and two on the right. On the left, from top to bottom: a 'TDM IF' (grey) connected to 'Packet Processing' (pink) which then connects to the 'Packet SW'; and a 'Packet IF' (yellow) connected directly to the 'Packet SW'. On the right, from top to bottom: a 'Packet IF' (yellow) connected directly to the 'Packet SW'; and a 'Packet IF' (yellow) connected to 'Depacket Processing' (pink) which then connects to the 'TDM IF' (grey). All external connections are shown with red arrows.
+
+L.1310(14)\_FA.3
+
+Figure A.3: Converged packet optical equipment I configuration (model III).
+
+**Figure A.3 – Converged packet optical equipment I configuration (model III)**
+
+
+
+Figure A.4 – Converged packet optical equipment I configuration (model IV). The diagram shows a central 'SW' (Switch) block containing a 'TDM SW' (TDM Switch). Above the SW block is a 'Clock' block connected by a dashed line. Below the SW block is a 'Monitor/control' block. On the left, there are two input paths: one from a 'TDM IF' (TDM Interface) and another from a 'Packet IF' (Packet Interface) through 'Depacket Processing'. Both paths lead into the 'TDM SW' block. On the right, there are two output paths: one from the 'TDM SW' block through 'Packet Processing' to a 'Packet IF' (Packet Interface), and another from the 'TDM SW' block to a 'TDM IF' (TDM Interface). The entire system is enclosed in a yellow rectangular box. The text 'L.1310(14)\_FA.4' is located at the bottom right of the diagram.
+
+**Figure A.4 – Converged packet optical equipment I configuration (model IV)**
+
+### A.2 Energy efficiency metrics
+
+The metrics for converged packet equipment shall be the maximum throughput per average power consumption.
+
+The metrics (telecommunications energy efficiency ratio (TEER)) designated by Alliance for Telecommunications Industry Solutions (ATIS) for transport equipment is as follows:
+
+$$\begin{aligned} \text{TEER}_{\text{CERT}} &= D_{\text{TEER}} / P_{\text{TEER-CERT}} \\ &= \sum D_i / \{(P_{\text{CERT-0}} + P_{\text{CERT-50}} + P_{\text{CERT-100}})/3\} \end{aligned} \quad (\text{A-1})$$
+
+where:
+
+$\text{TEER}_{\text{CERT}}$ : certified TEER measured at a specific configuration
+
+$D_{\text{TEER}}$ : total data rate (bit/s)
+
+$P_{\text{TEER-CERT}}$ : measured power consumption (W)
+
+$D_i$ : data rate (bps) at a given interface i
+
+$P_{\text{CERT-0}}$ : measured power consumption (W) at a 0% data traffic utilization
+
+$P_{\text{CERT-50}}$ : measured power consumption (W) at a 50% data traffic utilization
+
+$P_{\text{CERT-100}}$ : measured power consumption (W) at a 100% data traffic utilization.
+
+For converged packet optical equipment with packet and TDM functions, interface cards are added depending on the data usage volume. Therefore, in general,
+
+$$(P_{\text{CERT-0}} + P_{\text{CERT-50}} + P_{\text{CERT-100}})/3 \approx (P_{\text{CERT-0}} + P_{\text{CERT-100}})/2 \quad (\text{A-2})$$
+
+Thus, in practice, $\text{TEER}_{\text{CERT}}$ for converged packet optical equipment shall be as follows:
+
+$$\begin{aligned} \text{TEER}_{\text{CERT}} &= \sum D_i / \{(P_{\text{CERT-0}} + P_{\text{CERT-100}})/2\} \\ &= \text{Maximum throughput/average power consumption} \end{aligned} \quad (\text{A-3})$$
+
+a) The maximum throughput for converged packet optical equipment I
+
+$$= \sqrt{(A^2 + B^2)/2} \quad (\text{A-4})$$
+
+where:
+
+A: maximum throughput (Gbps) of packet functions
+
+(port speed (Gbit/s) × number of ports × number of slots)
+
+B: maximum throughput (Gbps) of TDM functions
+
+(port speed (Gbps) × number of ports × number of slots).
+
+b) The average power consumption for converged packet optical equipment I
+
+$$= (P_{\text{idle}} + P_{\text{max}}) / 2 \quad (\text{A-5})$$
+
+where:
+
+$P_{\text{idle}}$ : power consumption (W) of total equipment with no data throughput with minimum components and path configuration
+
+$P_{\text{max}}$ : power consumption (W) of total equipment during main signal transmission with maximum component configuration.
+
+The metric of converged packet optical equipment I is:
+
+$$\text{EER} = \sqrt{(A^2 + B^2)/2} / \{(P_{\text{idle}} + P_{\text{max}}) / 2\} \quad (\text{A-6})$$
+
+### A.3 Measurement methodology
+
+This clause defines measurement procedures for converged optical equipment I.
+
+a) Interface
+
+i) Selection of the interface
+
+Select the interface where the transmission capacity calculated using the following formula will be maximized for TDM and/or packet.
+
+Transmission capacity: port speed (Gbit/s) × number of ports × number of slots
+
+ii) Function combination patterns
+
+For the TDM interface and packet interface, conduct measurements selecting the configurable pattern at NNI side/UNI side from below:
+
+- TDM (NNI), TDM (UNI)
+- TDM (NNI), packet (UNI)
+- packet (NNI), TDM (UNI)
+- packet (NNI), packet (UNI)
+
+Select the pattern in which maximum throughput will be reached for the respective TDM/packet.
+
+iii) Interface when measuring $P_{\text{max}}$ configuration
+
+Use the interface selected in i), and configure using maximum slot/maximum port.
+
+iv) Interface when measuring $P_{\text{idle}}$ configuration
+
+Use the interface selected in i), and configure using 1 slot/1 port I/O.
+
+In the case of ring models, set up with a single-side path or convert the result to 1 slot/1 port configuration.
+
+v) Configuration for redundancy
+
+There is no specification of interface. When using an interface, calculate the transmission capacity with the redundant interface as part of the main unit.
+
+There is no specification for common components. (It shall be possible to have no common components.)
+
+Figure A.5 gives an example of maximum component configuration for measuring $P_{\text{max}}$ .
+
+
+
+Figure A.5: Example of maximum component configuration for measuring P\_max. The diagram shows a central green 'SW' (Switch) block. Above it is a blue 'Clock' block connected by dashed lines. Below it are two blue blocks: 'Monitor/control' and 'Power supply'. The 'Power supply' is connected to a pink 'Power meter' block, which is in turn connected to an external 'Power supply' label. The 'SW' block has two 'Packet IF' (Interface) blocks on its left and two 'TDM IF' blocks on its right. Each 'Packet IF' and 'TDM IF' has a blue double-headed arrow pointing outwards, labeled 'Max. rate'. There are vertical ellipses between the two 'Packet IF' blocks and between the two 'TDM IF' blocks. The diagram is labeled 'L.1310(14)\_FA.5' at the bottom right.
+
+**Figure A.5 – Example of maximum component configuration for measuring $P_{max}$**
+
+Figure A.6 gives an example of minimum component and path configuration for measuring $P_{idle}$ .
+
+
+
+Figure A.6: Example of minimum component and path configuration for measuring P\_idle. This diagram is similar to Figure A.5 but with 'No signal' labels on the blue double-headed arrows pointing outwards from the 'Packet IF' and 'TDM IF' blocks. The internal components (SW, Clock, Monitor/control, Power supply, Power meter) and their connections remain the same. The diagram is labeled 'L.1310(14)\_FA.6' at the bottom right.
+
+**Figure A.6 – Example of minimum component and path configuration for measuring $P_{idle}$**
+
+- b) Transmission load
+ - i) Transmission load when measuring $P_{max}$
+Maximum rate when configured at maximum capacity
+ - ii) Transmission load when measuring $P_{idle}$
+Non-transmitting state when configured with minimum paths at minimum capacity
+- c) Environmental conditions
+Environmental conditions are defined in clause 7.
+- d) Test voltage
+Test voltage is defined in clause 7.
+- e) Number of equipment measured
+There is no stipulation on number of equipment to be measured, but if multiple equipment is measured, indicate the average value.
+- f) Number of measurements
+There is no stipulation on number of measurements, but if measurements are taken multiple times, indicate the average value.
+- g) Measurement precision
+Not stipulated.
+
+# Annex B
+
+## Metrics and measurement methodologies for converged packet optical equipment with packet signal, TDM signal and WDM signal functions
+
+(This annex forms an integral part of this Recommendation.)
+
+### B.1 Equipment definition
+
+Converged packet optical equipment II refers to a type of transport equipment which transports (switches) multiple types of signals such as packet signals, TDM signals and WDM signals.
+
+The definition of these types of signals shall be as follows:
+
+**Packet signals:** Signals which include a MAC address relayed via ISO OSI layer 2 (data link layer) or an IP address relayed via ISO OSI layer 3 (network layer) or a label with routing information.
+
+**TDM signals:** TDM signals, such as STM-n/OC-n/OTU-n signals defined in SDH/SONET/OTN, as well as analogue signals conveying image or voice over telephone lines.
+
+**WDM signals:** WDM signals, which multiplex multiple optic signals with different wavelengths.
+
+The scope of this annex shall cover the following configuration model (Figure B.1):
+
+
+
+L.1310(14)\_FB.1
+
+Figure B.1 – Converged packet optical equipment II configuration diagram. The diagram shows a large box labeled 'Converged packet optical equipment II'. Inside, at the top, is a 'WDM function block' containing a dashed box labeled 'OADM/ROADM/OXC'. Multiple colored arrows (WDM signals) enter and exit this block from the left and right. Below the WDM function block are two 'TPND' blocks. Below these are two 'WDM IF' blocks. At the bottom is a block labeled '\* CPOE I block (Packet SW + TDM SW)'. This block contains 'Packet IF' and 'TDM IF' sub-blocks. Blue arrows (Packet signals) enter/exit the Packet IFs, and green arrows (TDM signals) enter/exit the TDM IFs. Black arrows (Client signals) also enter/exit the TPND blocks. The diagram is labeled 'L.1310(14)\_FB.1' at the bottom right.
+
+\*CPOE I: Converged packet optical equipment I
+
+**Figure B.1 – Converged packet optical equipment II configuration**
+
+Converged packet optical equipment II can be composed of multiple converged packet optical equipment I.
+
+### B.2 Energy efficiency metrics
+
+The metrics for converged packet optical equipment shall be the maximum throughput per average power consumption.
+
+The metrics (TEER) designated by ATIS for transport equipment is as follows:
+
+$$\begin{aligned} \text{TEER}_{\text{CERT}} &= D_{\text{TEER}} / P_{\text{TEER-CERT}} \\ &= \sum D_i / \{(P_{\text{CERT-0}} + P_{\text{CERT-50}} + P_{\text{CERT-100}})/3\} \end{aligned} \quad (\text{B-1})$$
+
+where:
+
+$\text{TEER}_{\text{CERT}}$ : certified TEER measured at a specific configuration
+
+$D_{\text{TEER}}$ : total data rate (bps)
+
+$P_{\text{TEER-CERT}}$ : measured power consumption (W)
+
+$D_i$ : data rate (bps) at a given interface i
+
+$P_{\text{CERT-0}}$ : measured power consumption (W) at a 0% data traffic utilization
+
+$P_{\text{CERT-50}}$ : measured power consumption (W) at a 50% data traffic utilization
+
+$P_{\text{CERT-100}}$ : measured power consumption (W) at a 100% data traffic utilization.
+
+For converged packet optical equipment with packet, TDM and WDM functions, interface cards are added depending on the data usage volume. Therefore, in general,
+
+$$(P_{\text{CERT-0}} + P_{\text{CERT-50}} + P_{\text{CERT-100}})/3 \approx (P_{\text{CERT-0}} + P_{\text{CERT-100}})/2 \quad (\text{B-2})$$
+
+Thus, in practice, $\text{TEER}_{\text{CERT}}$ for converged packet optical equipment with WDM signal function shall be as follows.
+
+$$\begin{aligned} \text{TEER}_{\text{CERT}} &= \sum D_i / \{(P_{\text{CERT-0}} + P_{\text{CERT-100}})/2\} \\ &= \text{Maximum throughput/average power consumption} \end{aligned} \quad (\text{B-3})$$
+
+a) The maximum throughput for converged packet optical equipment II
+
+The traffic pattern of converged packet optical equipment is as follows (Figure B.2):
+
+
+
+The diagram illustrates the internal architecture and traffic flow of 'Converged packet optical equipment II'. At the top, a 'WDM function block' receives and transmits 'WDM signal' (represented by orange arrows). Below this, a 'Packet signal' (blue arrows) and a 'TDM signal' (green arrows) are shown. The Packet signal flows through a 'Packet IF' (Interface) block, which is part of a '\* CPOE I block (Packet SW + TDM SW)'. The TDM signal flows through a 'TDM IF' block, also part of the '\* CPOE I block'. The Packet and TDM signals are then processed by 'WDM IF' blocks, which interface with the 'WDM function block'. The diagram also shows 'TPND' (Transponder) blocks and 'Client signal' outputs. A callout box notes that 'WDM-WDM and WDM-SW transmissions are not differentiated, since they are integral to the equipment'. The diagram is labeled 'L.1310(14)\_FB.2' at the bottom right.
+
+Diagram of Converged packet optical equipment II showing traffic patterns for WDM, Packet, and TDM signals.
+
+\*CPOE I: Converged packet optical equipment I
+
+**Figure B.2 – Definition of throughput of converged packet optical equipment II**
+
+**Table B.1 – Characteristic traffic of converged packet optical equipment included in throughput calculations**
+
+| Pathway | Throughput used for calculating figure of merit | Notes |
+|-------------------------------------------|---------------------------------------------------------------|----------------------------------------------------------------------------------|
+| (1) Transmitted as WDM (unchanged) | – | Not included since power consumption of OADM/ROADM/OXC parts is small |
+| (2) Add/drop from WDM to packet SW/TDM SW | WDM signal (C) throughput $\times$ Add/drop rate ( $\alpha$ ) | |
+| (3) Add/drop from WDM to transponder | – | Not included since not a major function of converged packet optical equipment II |
+| (4) Packet processing part | Packet signal (A) throughput | |
+| (5) TDM processing part | TDM signal (B) throughput | |
+
+where:
+
+- A: maximum throughput (Gbit/s) of packet functions
+(port speed (Gbit/s) $\times$ number of ports $\times$ number of slots)
+- B: maximum throughput of TDM function (Gbit/s)
+(port speed (Gbit/s) $\times$ number of ports $\times$ number of slots)
+- C: maximum throughput of WDM function (Gbit/s)
+(port speed (Gbit/s) $\times$ number of ports $\times$ number of slots)
+- $\alpha$ : add/drop rate of WDM function.
+
+The add/drop rate will change with operation status. The maximum capacity of the equipment is desired for $\alpha = 1$ .
+
+In order to maximize the use of converged packet optical equipment II features, the equipment shall be configured so that the traffic of WDM signals flowing into the converged packet optical equipment I part is maximized and the conditions of A, B, C and $\alpha$ are $C \times \alpha = A + B$ .
+
+NOTE – Please refer to [b-Ecology Guideline] for further details on formulas.
+
+- Maximum throughput of converged packet optical equipment with packet, TDM and WDM functions.
+
+$$\text{Maximum throughput} = \sqrt{[\{A^2 + B^2 + (C \times \alpha)^2\}/3]} \quad (\text{B-4})$$
+
+Furthermore, if packet or TDM functions are not supported, the following shall apply:
+
+- Maximum throughput of converged packet optical equipment with packet and WDM functions.
+
+$$\text{Maximum throughput} = \sqrt{[\{A^2 + (C \times \alpha)^2\}/2]} \quad (\text{B-5})$$
+
+- Maximum throughput of converged packet optical equipment with TDM and WDM signal functions.
+
+$$\text{Maximum throughput} = \sqrt{[\{B^2 + (C \times \alpha)^2\}/2]} \quad (\text{B-6})$$
+
+- b) The average power consumption for converged packet optical equipment II
+
+$$= (P_{\text{idle}} + P_{\text{max}}) / 2 \quad (\text{B-7})$$
+
+where:
+
+$P_{\text{idle}}$ : power consumption (W) of total equipment with no data throughput with minimum components and path configuration (WDM part: 1 wavelength, maximum frequency (ex: 1 wave $\times$ 100 Gbit/s))
+
+$P_{\text{max}}$ : power consumption (W) of total equipment during main signal transmission with maximum component configuration (WDM part: full wavelength, maximum frequency (ex: 80 wave $\times$ 100 Gbit/s)).
+
+Measurement of the average power consumption shall be taken from power consumption when configured for maximum transmission capacity.
+
+The metric of converged packet optical equipment II is:
+
+$$\text{EER} = \sqrt{\{(A^2 + B^2 + (C \times \alpha)^2)/3\} / \{(P_{\text{idle}} + P_{\text{max}})/2\}} \quad (\text{B-8})$$
+
+### B.3 Measurement methodology
+
+This clause defines measurement procedures for converged optical equipment II.
+
+#### a) Interface
+
+##### i) Selection of the interface
+
+Select the interface where the throughput of the WDM part ( $C \times \alpha$ ) is equivalent to the sum of the packet and TDM part throughputs ( $A+B$ ), and, as much as possible, WDM signals are added/dropped.
+
+##### ii) Function combination patterns
+
+For the TDM, packet and WDM interfaces, conduct measurements selecting the configurable pattern at NNI/UNI sides from the following:
+
+- WDM (NNI), TDM & packet (UNI)
+- WDM (NNI), TDM (UNI)
+- WDM (NNI), packet (UNI)
+
+##### iii) Interface when measuring $P_{\text{max}}$ configuration
+
+Use the interface selected in i), and configure using maximum throughput.
+
+##### iv) Interface when measuring $P_{\text{idle}}$ configuration
+
+Use the interface selected in i), and configure including 1 path with the WDM part.
+
+#### v) Configuration for redundancy
+
+There is no specification of interface when configured with redundancy. When configured with redundancy, calculate the figure of merit with the redundant interface as part of the main unit.
+
+Figure B.3 gives an example of maximum component configuration for measuring $P_{\text{max}}$ .
+
+
+
+Figure B.3: Example of maximum component configuration for measuring P\_max. The diagram shows 'Converged packet optical equipment II' containing a 'Packet processing block' and a 'WDM block'. The 'Packet processing block' includes a 'Common unit (Control/clock/FAN)' and a 'SW' (switch). It has two input interfaces: 'TDM IF (Note)' and 'Packet IF (Note)'. Both interfaces connect to the 'SW'. The 'SW' connects to two 'WDM IF' blocks. These 'WDM IF' blocks connect to the 'WDM block', which contains 'MUX/DMUX', 'Optical SW', and 'AMP'. The output of the 'AMP' is a 'WDM signal (Full wave length)'. Below the equipment block is a 'Power supply' connected to a 'Power meter', which is connected to a 'Power source'. The reference 'L.1310(14)\_FB.3' is shown.
+
+NOTE – Throughput of the TDM and packet functions is at its maximum, and all WDM signals can be added/dropped.
+
+**Figure B.3 – Example of maximum component configuration for measuring $P_{max}$**
+
+Figure B.4 gives an example of minimum component and path configuration for measuring $P_{idle}$ .
+
+
+
+Figure B.4: Example of minimum component and path configuration for measuring P\_idle. The diagram shows 'Converged packet optical equipment II' containing a 'Packet processing block' and a 'WDM block'. The 'Packet processing block' includes a 'Common block (Control/clock/FAN)' and a 'SW' (switch). It has one input interface: 'Packet IF' which receives 'No signal'. The 'Packet IF' connects to the 'SW'. The 'SW' connects to a 'WDM IF' block. This 'WDM IF' block connects to the 'WDM block', which contains 'MUX/DMUX', 'Optical SW', and 'AMP'. The output of the 'AMP' is a 'WDM signal (1 wave length)'. Below the equipment block is a 'Power supply' connected to a 'Power meter', which is connected to a 'Power source'. The reference 'L.1310(14)\_FB.4' is shown.
+
+**Figure B.4 – Example of minimum component and path configuration for measuring $P_{idle}$**
+
+- b) Transmission load
+ - i) Transmission load when measuring $P_{max}$
+Maximum throughput when configured at maximum capacity
+ - ii) Transmission load when measuring $P_{idle}$
+Non-transmitting state when configured with minimum paths at minimum capacity
+- c) Environmental conditions
+Environmental conditions are defined in clause 7.
+- d) Test voltage
+Test voltage is defined in clause 7.
+- e) Number of equipment measured
+
+There is no stipulation on number of equipment to be measured, but if multiple equipment is measured, indicate the average value.
+
+f) Number of measurements
+
+There is no stipulation on the number of measurements, but if measurements are taken multiple times, indicate the average value.
+
+g) Measurement precision
+
+Not stipulated.
+
+# Appendix I
+
+## Alternative metrics for wireline access technologies
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix reports an alternative metric available for wireline access technologies (including MSAN, DSLAM, GPON OLT and GEPON OLT).
+
+EER: This metric considers the maximum output bit rate per line at different traffic states as a functional unit (variable load → traffic related metric).
+
+$$\text{EER}_{\text{avg}} = \text{TOS}_{\text{avg}} / \text{P}_{\text{avg}} [\text{Mbit/s/W}] \quad (\text{I-1})$$
+
+where:
+
+$\text{TOS}_{\text{avg}}$ output bit rate per subscriber line is the weighted output bit rate for the subscriber (in Mbit/s) of the broadband network equipment in possible (if implemented) different operational states (L0, L2, L3).
+
+$$\text{TOS}_{\text{avg}} = a\text{TOS}_1 + b\text{TOS}_2 + c\text{TOS}_3 \quad (\text{I-2})$$
+
+$\text{P}_{\text{avg}}$ is the weighted energy consumption (in Watts) per line of the broadband network equipment in possible (if implemented) different states
+
+$$\text{P}_{\text{avg}} = a\text{P}_1 + b\text{P}_2 + c\text{P}_3 [\text{W}] \quad (\text{I-3})$$
+
+where:
+
+(a, b, c) are weight coefficients that are selected so that $(a + b + c) = 1$
+
+$\text{P}_1, \text{P}_2, \text{P}_3$ are power measurements (in Watts) of fully equipped broadband network equipment, operating in different traffic conditions, as defined below.
+
+### I.1 DSLAM and MSAN network equipment
+
+For this equipment, power is measured on a fixed loop length defined for any technology.
+
+The parameters a, b, c values consider the traffic distribution during the day.
+
+These values are established considering the distribution of traffic contained in [ETSI ES 203 215].
+
+$\text{P}_1, \text{P}_2, \text{P}_3$ are power measurements (in Watts) of fully equipped broadband network equipment operating in L0, L2 and L3 states (respectively) and collected under the terms defined in clause 9.2.1.
+
+The values are reported in Table I.1; they depend on the energy mode available in the equipment.
+
+**Table I.1 – Weight factor definition for DSLAM and MSAN**
+
+| Power mode available | Weight multipliers a, b, c |
+|----------------------|----------------------------|
+| L0, L2, L3 | a=0.15, b=0.06, c=0.79 |
+| L0, L2 | a=0.2, b=0.8, c=0 |
+| L0 | a=1, b=0, c=0 |
+
+The weight multipliers a, b, c are derived from Table B.1 in Annex B of [ETSI ES 203 215] considering the average traffic distribution during a day.
+
+### I.2 GPON OLT network equipment
+
+For GPON OLT equipment, EER is an indicator of the amount of traffic transported for each Watt of power in a fully equipped configuration.
+
+Since the power of typical OLT gear is not directly related to optical fibre length, it is not necessary to define a reference optical fibre length.
+
+$$\text{EER} = (\text{Bit rate per port}) / P_{\text{port}} [\text{Gbit/s/W}] \quad (\text{I-4})$$
+
+where:
+
+"Bit rate per port" is the downstream active data rate expressed in Gbit/s
+
+$P_{\text{port}}$ is the associated unit power consumption (in Watts) of the equipment.
+
+### I.3 GEPON OLT network equipment
+
+For GEPON OLT equipment, EER is an indicator of the number of available ports for each Watt of power in a fully equipped configuration.
+
+For OLT, use a value that divides average power consumption for the OLT (at full mounting), measured using DC input if the equipment power source is DC and AC input if the power source is AC, by the total number of lines (Total number of interface (IF) ports $\times$ number of PON branches).
+
+$$\text{EER} = \text{total number of IF ports} / \text{average power} \quad [\text{line/W}] \quad (\text{I-5})$$
+
+where:
+
+Average power = (power at 100% load + power at 50% load + power at 0% load) / 3.
+
+NOTE – It is possible to obtain a metric of the number of subscriber lines by multiplying the defined EER by the number of branches (e.g., 32).
+
+# Appendix II
+
+## Alternative metrics for routers and switches
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix reports some alternative metrics available for routers and switches.
+
+### II.1 Routers and switches supporting sleep (standby) mode
+
+This metric is applicable only to routers and switches that can change to sleep mode.
+
+The proposed metric is:
+
+$$\text{EER} = T_i/P_i \quad [\text{Mbit/s/W}] \quad (\text{II-1})$$
+
+where:
+
+$$P_i = c \times P_{\max} + b \times P_{\text{typical}} + a \times P_{\text{idle}} + d \times P_{\text{sleep}} \quad [\text{W}] \quad (\text{II-2})$$
+
+$T_i$ is the weighted throughput
+
+$$T_i = c \times T_{\max} + b \times T_{\text{typical}} + a \times T_{\text{idle}} \quad (\text{II-3})$$
+
+$(T_{\max}, T_{\text{typical}}, T_{\text{idle}})$ = throughput measured at respective utilization levels
+
+where:
+
+- $P_{\max}$ is the power at maximum traffic load in real time; here maximum traffic load is defined as maximum non-drop rate, equivalent to 100% load ( $u_3$ in [ATIS-0600015.03.2023])
+ - $P_{\text{typical}}$ is the power at typical traffic load in real time; here typical traffic load is defined as 30% load or 10% load which is dependent on the different equipment types ( $u_2$ in [ATIS-0600015.03.2023])
+ - $P_{\text{idle}}$ is the power in idle state in real time; here idle state is defined in 0% load ( $u_1$ in [ATIS-0600015.03.2023])
+ - $P_{\text{sleep}}$ is the power in sleep mode in non-real time, applicable only for equipment that offers sleep mode.
+ - $c$ is the weighting multiplier for maximum state in real time,
+ - $b$ is the weighting multiplier typical traffic load in real time,
+ - $a$ is the weighting multiplier for idle traffic load in real time,
+ - $d$ is the weighting multiplier for sleep mode in non-real time,
+- $$a + b + c + d = 1.$$
+
+The values of parameters $a$ , $b$ , $c$ and $d$ are defined in Table II.1 for routers and in Table II.2 for switches. Such parameters are derived from the contents of [ATIS-0600015.03.2023] adding the "new" state of sleep mode (related to weight $d$ ) considering an average distribution of the traffic during the day.
+
+Values for $a$ , $b$ , $c$ and $d$ shall be substantiated with data; sleep/standby mode can be used in a limited number of networking devices, but only if nothing is attached to the device network connection. For this group of routers/switches, expected traffic is close to idle.
+
+**Table II.1 – Weight factor definition for routers**
+
+| Class | Representative utilization | % of utilization for energy measurements, u1, u2, u3 | Weight multipliers a, b, c, d |
+|---------------------------------------|----------------------------|------------------------------------------------------|-----------------------------------|
+| Access router with sleep mode support | 1%-3% | 0, 10, 100 | a=0.15, b=0.25, c=0.15, d=0.45 |
+
+**Table II.2 – Weight factor definition for switches**
+
+| Class | Representative utilization | % of utilization for energy measurements, u1, u2, u3 | Weight multipliers a, b, c, d |
+|---------------------------------------|----------------------------|------------------------------------------------------|-----------------------------------|
+| Access switch with sleep mode support | 1%-3% | 0, 10, 100 | a=0.15, b=0.25, c=0.15, d=0.45 |
+
+### II.2 Measurement methodology
+
+Measurement methodology shall be in line with [ATIS-0600015.03.2023], excluding what was reported in clause 7 and the sleep mode defined below.
+
+#### Power measurement for sleep mode
+
+With each of the equipment's ports operating in sleep mode for 20 minutes, record the average input power over 15 minutes.
+
+### II.3 Routers and switches supporting explicit power states
+
+# Definitions
+
+**Power state:** A mode of operation with reduced performance and reduced energy consumption. Power state is a static, not a traffic-dependent, mode of operation. Transition between power states is not instantaneous and may incur a delay during which excess traffic might be lost.
+
+**Duty cycle:** The duration for each power mode to a specific time period (day, week, etc.)
+
+**EENRT :** Energy efficiency for equipment with non-real time adjustment for traffic (explicit power states).
+
+To evaluate EENRT , three measurement points that may correspond to different power states of unit under test (UUT) are defined:
+
+- 1) S0 – full performance
+- 2) S1 – 30% performance
+- 3) S2 – 10% performance
+
+A sample duty cycle is defined as a fraction of time during which the planned traffic levels are applicable. Level 0 will be used for 55% of duty period, level 2 for 25%, and level 3 for 20% of the duty period.
+
+$$EE_{NRT} = (0.55T_{S0} + 0.25T_{S1} + 0.2T_{S2}) / (0.55P_{S0} + 0.25P_{S1} + 0.2P_{S2}) [Gbps/W] \quad (II-3)$$
+
+where:
+
+TS0 , TS1 , TS2 is the throughput in the three measurement points
+
+PS0 , PS1 , PS2 is the power in the three measurement points.
+
+# Bibliography
+
+- [b-ITU-T L.1315] Recommendation ITU-T L.1315 (2017), *Standardization terms and trends in energy efficiency*.
+- [b-Ecology Guideline] Ecology Guideline For the ICT Industry (Version 5). (2014)
+<[http://www.tca.or.jp/information/pdf/ecoguideline/guideline\\_eng\\_5.pdf](http://www.tca.or.jp/information/pdf/ecoguideline/guideline_eng_5.pdf)>
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1318-202208-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/L/T-REC-L.1318-202208-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1e32f9b8f1141bed243c16e02a6cd1411cbb87f1
--- /dev/null
+++ b/marked/L/T-REC-L.1318-202208-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c395c4bbde83b1e232652a43f51538278c116f51f710c37e20a073f7333726c8
+size 6134
diff --git a/marked/L/T-REC-L.1318-202208-I_PDF-E/raw.md b/marked/L/T-REC-L.1318-202208-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..9322dc7a8c63c75eee199edd4e9fe4ca308263e7
--- /dev/null
+++ b/marked/L/T-REC-L.1318-202208-I_PDF-E/raw.md
@@ -0,0 +1,440 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1318**
+
+(08/2022)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+Energy efficiency, smart energy and green data centres
+
+---
+
+**Q factor: A fundamental metric expressing
+integrated circuit energy efficiency**
+
+Recommendation ITU-T L.1318
+
+# ITU-T L-SERIES RECOMMENDATIONS
+
+## ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
+
+| | |
+|---------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000–L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200–L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300–L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400–L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500–L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600–L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700–L.1799 |
+
+For further details, please refer to the list of ITU-T Recommendations.
+
+## Recommendation ITU-T L.1318
+
+## **Q factor: A fundamental metric expressing integrated circuit energy efficiency**
+
+## **Summary**
+
+Recommendation ITU-T L.1318 outlines a method and fundamental metric for expressing integrated circuit energy efficiency, the Q factor. The Q factor could be applied to measure and improve the integrated circuit technology behind information and communication technology itself.
+
+The method consists of two separate parts:
+
+- 1) Method and metric development;
+- 2) Examples of Q factor scores for different integrated circuits and energy and carbon saving potentials in relation to Q factors.
+
+## **History**
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1318 | 2022-08-13 | 5 | 11.1002/1000/15027 |
+
+## **Keywords**
+
+Energy efficiency, integrated circuit, metric.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2022
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 1 |
+| 5 Conventions ..... | 2 |
+| 6 The framework or methodology — method and metric development ..... | 2 |
+| 6.1 The framework or methodology for Q factor ..... | 2 |
+| 6.2 The Q factor metric with examples of Q factor scores..... | 3 |
+| Appendix I – Challenges, feasible technologies and recent and ongoing work ..... | 4 |
+| Appendix II – Carbon saving potential: energy and carbon saving potential relation to Q factor ..... | 5 |
+| Appendix III – Example of governmental programme mandating energy efficient computers..... | 7 |
+| Appendix IV – Performance metrics for different semiconductor technologies and the corresponding electricity use ..... | 8 |
+| Bibliography..... | 10 |
+
+## Introduction
+
+As [b-Lewis] describes, current computing technology is not sustainable, owing to the increased heat generation that accompanies the ever increasing capability of chips. The large number of such chips packed into a limited space makes cooling a major challenge, which will eventually become insurmountable. Therefore, it is likely that the trend of improved performance provided by increased power consumption is reaching its end, unless the relationship between performance and heat generation can be broken by new technological solutions. Energy-efficient computing, and reversible adiabatic1 computing specifically, could be one of these solutions, as it would fulfil the need described by [b-Lewis] to reduce power consumption per unit of computation, potentially within the next ten years.
+
+[b-Andrae] provides a comparison of the energy efficiency of reversible versus conventional computing: "If a traditional 180 W processor chip using 5 nm node ... would process the anticipated operations in 2030 with current transistor technology, an absurd amount of electricity will be used for computing. The same chip using reversible computing would use only 0.08 W." Appendix IV presents tables of performance metrics for different semiconductor technologies and the corresponding electricity use.
+
+There are several ways in which the energy efficiency of integrated circuits (ICs) can be expressed. [b-Kenneth] proposed a Q factor based on radian frequency, electrical and magnetic energies stored in the IC, and the power dissipation from the IC. [b-Ionescu] proposed the E factor, an energy factor related to the state change in the field-effect transistors, dependent on physics, materials and voltages.
+
+The focus of this Recommendation is the Q factor as a metric by which the energy efficiency of IC technologies can be measured. The Q factor described herein thus provides a way of establishing the energy efficiency of ICs, computing and information and communication technology (ICT).
+
+---
+
+1 Adiabatic: Greek term for a "closed system", in contrast to the term diabatic for an "open system".
+
+## Recommendation ITU-T L.1318
+
+## **Q factor: A fundamental metric expressing integrated circuit energy efficiency**
+
+## **1 Scope**
+
+This Recommendation defines the integrated circuit metric for energy efficiency (TIME) as the Q factor (also known as "quality factor" or "Q"). Q factor provides a key means to accurately express energy efficiency at the integrated circuit (IC) level.
+
+This Recommendation defines Q factor as a metric for IC energy efficiency;
+
+This Recommendation is applicable to all ICs and differentiates ICs with $Q \geq 1000$ (highly energy efficient) from those ICs with $Q = 1$ (current ICs).
+
+## **2 References**
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+None.
+
+## **3 Definitions**
+
+### **3.1 Terms defined elsewhere**
+
+None.
+
+### **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 dynamic energy used per cycle:** The average energy consumed for one switching transition of a device.
+
+**3.2.2 energy dissipated per cycle:** The energy required to erase one bit of information.
+
+**3.2.3 irreversible:** A process that is not reversible, thermodynamically limited.
+
+**3.2.4 quality factor (Q factor):** Ratio of dynamic energy used per cycle to energy dissipated per cycle.
+
+**3.2.5 reversible:** Not thermodynamically limited, capable of circumventing thermodynamic limits.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+**BARC** Ballistic Asynchronous Reversible Computing
+
+**BARCS** Ballistic Asynchronous Reversible Computing in Superconductors
+
+**CMOS** Complementary Metal Oxide Semiconductor
+
+| | |
+|---------|--------------------------------------------------------------|
+| IC | Integrated Circuit |
+| ICT | Information and Communication Technology |
+| PUE | Power Usage Effectiveness |
+| Q2LAL | Quiet Two-Level Adiabatic Logic |
+| R-QCA | Reversible Quantum-dot Cellular Automaton |
+| RA-CMOS | Reversible Adiabatic Complementary Metal Oxide Semiconductor |
+| RNRL | Reversible Nanomechanical Rod Logics |
+| RQFP | Reversible Quantum Flux Parametron |
+| S2LAL | Static Two-Level Adiabatic Logic |
+| TIME | The Integrated circuit Metric for Energy efficiency |
+
+## 5 Conventions
+
+None.
+
+## 6 The framework or methodology – method and metric development
+
+### 6.1 The framework or methodology for Q factor
+
+The framework or methodology for the Q factor metric – defined by Equations (1) to (3) – is the physics of information, that is, physical information and the physical foundations of computation.
+
+Q factor ( $Q$ ) – as expressed in this Recommendation – is a new metric to express the energy efficiency of ICs.
+
+$Q$ is a dimensionless parameter expressed as the ratio of dynamic energy used per cycle ( $E_{\text{dyn}}$ ) to energy dissipated per cycle ( $E_{\text{diss-heat}}$ ). Q factor ( $Q$ ) is a metric based on Landauer's principle for the measurement of energy efficiency for ICs, namely $E_{\text{diss-heat}} = kT \ln 2$ .
+
+Equations (1) to (3) describe how $Q$ is derived:
+
+$$Q = E_{\text{dyn}}/E_{\text{diss-heat}} \quad (1)$$
+
+$$E_{\text{dyn}} = (C_L \times V^2) + 1/(\alpha \times f_c) \times I_{\text{off}} \times V \quad (2)$$
+
+$$E_{\text{diss-heat}} = k_b \times T \times \ln 2 \quad (3)$$
+
+where:
+
+| | |
+|------------------------|--------------------------------------------------------------|
+| $Q$ | is the quality factor |
+| $E_{\text{dyn}}$ | is the dynamic energy used per cycle |
+| $E_{\text{diss-heat}}$ | is the energy dissipated per cycle |
+| $\alpha$ | is the switching probability |
+| $f_c$ | is the clock frequency |
+| $I_{\text{off}}$ | is the leakage current from each switch in the off-state |
+| $C_L$ | is the load capacitance |
+| $V$ | is the voltage across the gate |
+| $k_b$ | is the Boltzmann constant [J/K], and |
+| $T$ | is the temperature at which the transistor is operating [K]. |
+
+Appendix I describes challenges in the development of more energy efficient IC technology, lists feasible such technologies and presents recent and ongoing work that can lead to their development.
+
+### 6.2 The Q factor metric with examples of Q factor scores
+
+Table 1 shows Q factor scores for the reversible computing technologies listed in Appendix I, and which promise levels of energy efficiency significantly greater than that of current computing.
+
+**Table 1 – Expected Q factor performance scores for "information is physical" reversible computing technologies**
+
+| Technology | Q | Features | Readiness level |
+|-----------------------------------------------------------------------------------|------------------------------|--------------------------------------|-----------------|
+| 1. Reversible adiabatic CMOS (RA-CMOS) | $\geq 1000$ [b-Frank-2] | Room temperature, 300 Kelvin, CMOS | Near-term |
+| 2. Reversible quantum flux parametron (RQFP) | Ultra-high-Q | Superconducting resonators | Mid-term |
+| 3. Reversible quantum-dot cellular automaton (R-QCA) | 10 000 to 100 000 [b-Torres] | Cryogenic (4 Kelvin), superconductor | Long-term |
+| 4. Reversible nanomechanical rod logics (RNRL) | | | Very long-term |
+| 5. Ballistic asynchronous reversible computing in superconductors (BARC or BARCS) | | | Very long-term |
+| NOTE – In current computing, Q = 1. | | | |
+
+As stated in clause 6.1, the methodology for the Q metric [b-Frank-2] involves the fundamentals of the physics of information [b-Anderson]. RA-CMOS technology, specifically S2LAL combined with the High-Q resonator [b-Frank-3], in page 29 provides a potential near-term solution.
+
+*Q* = 1 refers to end-of-nodes in [b-ITRS].
+
+Appendix II shows potential carbon saving from different achievements of values of *Q*.
+
+Appendix III shows an example of how energy efficient computers can be mandated by governments.
+
+## Appendix I
+
+### Challenges, feasible technologies and recent and ongoing work
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The challenge in developing energy efficient computing technology lies in educating the ICT sector of the need for "fundamental understanding of computation as a distinct physical process with information as its physical currency" as stated by [b-Anderson] in a special issue of the Entropy journal [b-Entropy], dedicated to clarifying and advancing "the physical understanding of information and computation." Gaining such an understanding in a timely manner will enable the ICT sector to navigate the technology inflection point from diabatic to adiabatic computing and meet the ICT sector 1.5°C by 2025 trajectory.
+
+Feasible technologies for developing energy efficient computing are described in the Entropy journal cover article "Quantum Foundations of Classical Reversible Computing" [b-Frank-2]. The five existing and proposed reversible computing technologies are based on the methodology of the physics of information and are far more energy efficient than the current diabatic irreversible computing technology:
+
+- 1 RA-CMOS
+- 2 RQFP
+- 3 R-QCA
+- 4 RNRL
+- 5 BARC or BARCS.
+
+(See clause 6.2 for Q factor values for some of the above technologies.)
+
+The near-term implementation impact path will likely involve the first computing technology in the above list – RA-CMOS: "this class of implementation technologies for reversible computing refers to a logic design discipline based on ordinary CMOS (complementary metal-oxide-semiconductor) field-effect transistors..." [b-Frank-2], p. 36. The implementation of technologies 2, 3, 4 and 5 is – due to their readiness – realistic in either mid-term or long-term.
+
+Recent and ongoing work within the RA-CMOS technology are: S2LAL, which "should be capable of demonstrating a greater level of energy efficiency than *any* other semiconductor-based digital logic family known today" [b-Frank-1]; Q2LAL, with improvements to S2LAL [b-DeBenedictis]; and a patent-pending high-Q resonant oscillator to provide power supplies suitable for driving adiabatic circuits [b-Frank-3] is reported in page 29, with an efficiency goal of $Q \geq 1000$ .
+
+## Appendix II
+
+### Carbon saving potential: energy and carbon saving potential relation to $Q$ factor
+
+(This appendix does not form an integral part of this Recommendation.)
+
+[b-ITU-T L.1470] describes the carbon footprint of the ICT sector as largely dependent on the use of electricity and its carbon intensity, and that ICT is electrified but not decarbonized. Decarbonizing the electricity supply with power from renewable sources will help to lower greenhouse gas emissions. However, the energy efficiency of the computing technology behind ICT must itself be addressed. Making that technology so energy efficient that ICT usage requires less electricity to begin with will contribute to decarbonizing ICT, thus reducing the sector's global greenhouse gas emissions. An additional benefit could be better durability of equipment.
+
+Current IC technology has $Q = 1$ – virtually all the energy going in goes out – as waste heat. "As of 2011, computers have a computing efficiency of about 0.00001%" [b-Lewis]. This $Q = 1$ energy inefficiency has a high cost, requiring as much electricity to cool the ICT as to run it, as illustrated in Table II.1, which shows the allocation of data centre electricity usage for data centres in the USA in 2014 [b-Energy]. Hence the power usage effectiveness (PUE) in 2014 was, on average, 2.32. Current data centres focusing on efficiency typically achieve PUE values of 1.2 or less [b-NREL].
+
+**Table II.1 – Allocation of data centre electricity usage in the USA in 2014**
+
+| Data centre electricity end use | Approx. % |
+|-------------------------------------|-----------|
+| Servers | 43 |
+| Cooling and power provision systems | 43 |
+| Storage drives | 11 |
+| Network | 3 |
+
+Note that in Table II.1 the percentages allocated to servers and to cooling and power provision are equal – 43%. Today's computers, which run on technology with $Q = 1$ , dissipate virtually all the energy input as waste heat; therefore, it is not surprising that it takes as much electricity to cool today's computers as it does to run them.
+
+Because $Q \geq 1000$ computers would operate so efficiently and produce so little heat, costs related to both the cooling systems and processing should become minimal, again significantly reducing the amount of electricity needed and corresponding emissions. In addition, the impact on precious resources directly or indirectly used for current cooling needs – such as water [b-Mytton] – would be greatly lessened.
+
+Looking at the data centre subsector, Table II.2 compares the potential difference in electricity consumption between current $Q = 1$ IC technology and $Q = 1000$ IC technology.
+
+**Table II.2 – Comparison of data centre electricity consumption with $Q = 1$ vs $Q = 1000$ IC technology [b-ITU-T L.1470], Table A-1**
+
+| $Q$ | Electricity (TWh) | | | |
+|------|-------------------|--------|--------|--------|
+| | 2015 | 2020 | 2025 | 2030 |
+| 1 | ≈205 | ≈215 | ≈235 | ≈257 |
+| 1000 | ≈0.205 | ≈0.230 | ≈0.235 | ≈0.277 |
+
+For data centre servers using $Q = 1000$ computing technology ICs, the electricity consumption would be *significantly* reduced, by at least a factor of 1000.
+
+Similarly, Table II.3 compares the use state power values for combined data centres and enterprise networks and illustrates that electricity requirements would be far lower when $Q = 1000$ .
+
+**Table II.3 – Comparison of electricity consumption for data centres and enterprise networks with $Q = 1$ vs $Q = 1000$ IC technology [b-ITU-T L.1470], Tables V.3, V.4**
+
+| $Q$ | Electricity (TWh) | |
+|------|-------------------|--------|
+| | 2015 | 2030 |
+| 1 | ≈220 | ≈411 |
+| 1000 | ≈0.220 | ≈0.411 |
+
+The carbon saving potential comes from developing ICT with a high $Q$ value to replace current $Q = 1$ ICT. Vastly lowered power requirements in data centres – resulting from using ICT that in turn uses ICs with high $Q$ value – will make it feasible to install onsite renewable energy sources, especially, for example, solar photovoltaic systems with battery backup, eliminating emissions caused by transmission and distribution losses [b-Surana], [b-US].
+
+## Appendix III
+
+### **Example of governmental programme mandating energy efficient computers**
+
+(This appendix does not form an integral part of this Recommendation.)
+
+As of 2021, computers sold in the state of California (United States of America) must meet energy consumption standards. According to a 2016 report [b-California-1] by the state's Energy Commission, computers and computer monitors in the state account for up to 2.9 percent of residential electricity use and 7 percent of commercial electricity use, primarily in offices and schools. In order to reduce the state's carbon footprint, California adopted appliance energy consumption standards for computers and computer monitors, and the standards came fully into effect in 2021 [b-California-2]. Manufacturers must certify with the California Energy Commission that their products meet the standards [b-California-3]. This information is available to the public.
+
+## Appendix IV
+
+### Performance metrics for different semiconductor technologies and the corresponding electricity use
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes current (2020) and future estimates (2030) for different semiconductor technologies and the corresponding electricity use. Tables IV.1 and IV.2 use approaches from section III.D in [b-Andrae].
+
+Table IV.1 provides estimates of the amounts of electricity used for computation in 2020 under certain assumptions.
+
+**Table IV.1 – Performance metrics for different semiconductor technologies and the corresponding electricity use in 2020**
+
+| Metric | Typical CMOS today, 1 | Typical CMOS today, 2 | |
+|-------------------------------------------|----------------------------------|----------------------------------|----------------------------|
+| Node | 7 nm | 14 nm | |
+| Power, W | 300 | 100 | |
+| GFLOP/s | 20 700 | 9000 | FLOP $\approx$ computation |
+| GFLOP/s/W | 69 | 90 | |
+| pJ/computation | 14.5 | 11.1 | |
+| Computations/s global in 2020 | $\approx 1.57 \times 10^{22}$ | | |
+| TWh globally per year for all computation | 1993 | 1528 | |
+| MW to run a 1 EFLOP/s machine | 14.5 | 11.1 | |
+
+Table IV.2 provides estimates of the amounts of electricity to be used in 2030 under certain assumptions of future performance.
+
+**Table IV.2 – Performance metrics for different semiconductor technologies and the corresponding electricity use in 2030**
+
+| Metric | Typical CMOS today,1 | Typical CMOS today,2 | CMOS theoretical prediction 2030,1 | CMOS theoretical prediction 2030,2 | Reversible logic | |
+|-------------------------------------------|-------------------------------|----------------------|------------------------------------|------------------------------------|------------------|----------------------------|
+| Node | 7 nm | 14 nm | | | | |
+| Power, W | 300 | 100 | | 180 | 0.08 | |
+| GFLOP/s | 20 700 | 9000 | | 5 7600 | 57 600 | FLOP $\approx$ computation |
+| GFLOP/s/W | 69 | 90 | 5498 | 320 | 720 000 | |
+| pJ/computation | 14.5 | 11.1 | 0.182 | 3.12 | 0.0014 | |
+| Computations/s globally in 2030 | $\approx 3.08 \times 10^{24}$ | | | | | |
+| TWh globally per year for all computation | $\approx 390\ 000$ | $\approx 300\ 000$ | $\approx 4900$ | $\approx 84\ 000$ | $\approx 37$ | |
+| MW to run a 1 EFLOP/s machine | 14.5 | 11.1 | 0.182 | 3.12 | 0.0014 | |
+
+With the achievement of $\approx 3$ yottacomputations/s in 2030, the J/computation should improve 41% per year from 2020 to 2030, reaching 0.074 pJ/computation (13 500 GFLOP/s/W), to keep computing electricity flat.
+
+## Bibliography
+
+- [b-ITU-T L.1470] Recommendation ITU-T L.1470 (2020), *Greenhouse gas emissions trajectories for the information and communication technology sector compatible with the UNFCCC Paris Agreement*.
+- [b-Anderson] Anderson, N.G. (2021), *Entropy Special Issue*, Entropy, Vol. 23, No. 6.
+- [b-Andrae] Andrae, A.S.G. (2019), *Prediction Studies of Electricity Use of Global Computing in 2030*. Int. J. Sci. Eng. Invest. Vol. 8, No. 86, pp. 27–33.
+- [b-California-1] California Energy Commission. (2016). *2016 Appliance Efficiency Rulemaking, Staff Report: Final Analysis of Computers, Computer Monitors, and Signage Displays*.
+- [b-California-2] California Energy Commission. (2021). *CEC Compliance Advisory: Appliance Efficiency Regulations For Computers And Computer Monitors*.
+- [b-California-3] California Energy Commission. (2022). *Appliance Regulations Certification Assistance*.
+- [b-DeBenedictis] DeBenedictis, E.P. (2021), *Energy Management for Adiabatic Circuits*.
+- [b-Energy] Energy Innovation Policy & Technology (2020), *How Much Energy Do Data Centers Really Use?*
+- [b-Entropy] Entropy (2021), Vol. 23, No. 6 (June).
+- [b-Frank-1] Frank, M.P., Brocato, R.W., Tierney, B.D., Missert, N., Hsia, A.H. (2020). *Reversible Computing with Fast, Fully Static, Fully Adiabatic CMOS*. 2020 Int'l Conf. on Rebooting Computing (ICRC), Atlanta, Georgia, USA, Dec. 1–3.
+- [b-Frank-2] Frank, M.P., Shukla, K. (2021), *Quantum Foundations of Classical Reversible Computing*, Entropy, Vol. 23, No. 6, pp. 701.
+- [b-Frank-3] Frank, M.P. (2021). *Current Status of Reversible Computing*.
+- [b-Ionescu] Ionescu, A.M. (2017), *Energy efficient computing and sensing in the Zettabyte era: From silicon to the cloud*. 2017 IEEE International Electron Devices Meeting (IEDM) pp. 1–2).
+- [b-ITRS] International Technology Roadmap for Semiconductors (2013).
+- [b-Kenneth] Kenneth, O. (1998), *Estimation methods for quality factors of inductors fabricated in silicon integrated circuit process technologies*. IEEE Journal of Solid-state circuits, Vol. 33, No. 8, pp. 1249-1252.
+- [b-Lewis] Lewis, T.G., Scott, A. (2021), *Sustainable Computing*. February, 10 pp.
+- [b-Mytton] Mytton, D. (2021), *Data Centre Water Consumption*. npj Clean Water, Vol. 4, No. 11.
+- [b-NREL] National Renewable Energy Laboratory, High-Performance Computing Data Center Power Usage Effectiveness, 2020.
+
+- [b-Surana] Surana, K., & Jordaan, S. M. (2019). *The climate mitigation opportunity behind global power transmission and distribution*. *Nature Climate Change*, 9(9), 660-665.
+- [b-Torres] Torres, F.S. (2021, June 20). Private email re Torres, F. S., Niemann, P., Wille, R., & Drechsler, R. (2019). *Near zero-energy computation using quantum-dot cellular automata*. *ACM Journal on Emerging Technologies in Computing Systems (JETC)*, 16(1), 1-16
+- [b-US] U.S. Energy Information Administration (2021), *How Much Electricity is Lost in Electricity Transmission and Distribution in the United States?* 4 November 2021.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..288d0eb11e4e83229b15cdcad74a427f36f80bf0
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a5e715cd61bdf3341bed2754994dbfefa756721b70089ec0b5e2935b376e3370
+size 25171
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/16c1175b5f05a4b55e6d396fc51b15b3_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/16c1175b5f05a4b55e6d396fc51b15b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b03e53eef8632398bc3ccfcc45c40c21d80e7b55
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/16c1175b5f05a4b55e6d396fc51b15b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6c3ee5287f7b2927610a576e283e456ed8fed1d7d439a761f5659e8f315ce990
+size 39066
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1c8ff9c55c1a3fa9994a07db218d7cfb2722b449
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:02c85f3c7db5d5563b0b9a624f454498b5b516c19d733f7195a4e105603eed0b
+size 31830
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cd87b67a80781bdc8651f3fb4fdf858aab51b485
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c16fe20d7feb1cb21dd7716b6d643499b19d97c5ee10d9d88b5aba00edb9a36a
+size 31160
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c112348bd6d8c0905cce263394e83c7fbb5016ae
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aec75a683979834b2b8e16032ee02dbe493be684d890725fcd2511933bb93cef
+size 30135
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ba750b7845f725c453345d09bf1419b5322b735
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bb4d5dea6e75869a6133677420bb326254e6fc56b67de53ce18185444eb4590e
+size 28971
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/cd91fd97c6e4da454b42f4fde13f7e44_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/cd91fd97c6e4da454b42f4fde13f7e44_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a7fa63fb4392b71386bd49cbc6511f9a610e265f
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/cd91fd97c6e4da454b42f4fde13f7e44_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bc006f23778a093d31040176522864b8f9a3dc0d23ab858b4eb2125fa4cd5274
+size 30160
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c12e1ea7e74ea5279c7a789f9f4fa7060266710a
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:21d19a8d4bcae9ef313adfa8414bea62e62b5f4520b1e880669c926162635a11
+size 8720
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/e787e02d9214556476d95941bda1d350_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/e787e02d9214556476d95941bda1d350_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9992f9d288f701388ce6f0b34ebcb54d47897a53
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/e787e02d9214556476d95941bda1d350_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:347431e3863bc7ebde6747e2c1bbde258bcd33fd8b3fc369074757a25938ac6e
+size 21461
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..529e4f72f14cdf7f41f56cfbfb26655bf8181c59
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:abb9e3ec6dfc8364cedc39a68cf796e9d3ff5529c79a1811eedeb12c6d6e7583
+size 3787
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94149eb0e35693a863d0731972faf1d575ec865d
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:76d4a80e6e592f60f2b645b2c199a5513c9d66fcd6ba31ebed7db069c81083ec
+size 30625
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/fed351d1b7c4568a439a8682c27f8cc3_img.jpg b/marked/L/T-REC-L.1320-201403-I_PDF-E/fed351d1b7c4568a439a8682c27f8cc3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3b479e2632e99105c94cb737ea38a2634a439436
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/fed351d1b7c4568a439a8682c27f8cc3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:653a8ca93e08c2a93841d3a5f039c7d8e5bd3417311ad447265b1d9e00a0ab9b
+size 54938
diff --git a/marked/L/T-REC-L.1320-201403-I_PDF-E/raw.md b/marked/L/T-REC-L.1320-201403-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..f5f158b3d24cf347e6f69d0e958cdb517ac3c7cf
--- /dev/null
+++ b/marked/L/T-REC-L.1320-201403-I_PDF-E/raw.md
@@ -0,0 +1,746 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1320**
+
+(03/2014)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS
+OF OUTSIDE PLANT
+
+---
+
+**Energy efficiency metrics and measurement for
+power and cooling equipment for
+telecommunications and data centres**
+
+Recommendation ITU-T L.1320
+
+
+
+# Recommendation ITU-T L.1320
+
+## Energy efficiency metrics and measurement for power and cooling equipment for telecommunications and data centres
+
+## Summary
+
+Recommendation ITU-T L.1320 contains the general definition of metrics, test procedures, methodologies and measurement profiles required to assess the energy efficiency of power and cooling equipment for telecommunications and data centres. More detailed measurement procedures and specifications can be developed in future related ITU-T Recommendations.
+
+Metrics and measurement methods are defined for power equipment, alternating current (AC) power feeding equipment (such as AC uninterruptible power supply (UPS), direct current (DC/AC) inverters), DC power feeding equipment (such as AC/DC rectifiers, DC/DC converters), solar equipment, wind turbine equipment and fuel cell equipment.
+
+In addition, metrics and measurement methods are defined for cooling equipment such as air conditioning equipment, outdoor air cooling equipment and heat exchanging cooling equipment.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1320 | 2014-03-22 | 5 | 11.1002/1000/12136 |
+
+## Keywords
+
+Energy efficiency, methodology, metrics.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2014
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-----------------------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 3.1 Terms defined elsewhere ..... | 2 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 General test methodology ..... | 3 |
+| 5.1 Power feeding equipment efficiency testing ..... | 3 |
+| 5.2 Cooling equipment efficiency testing..... | 8 |
+| Appendix I – Example of conditions for power feeding equipment efficiency testing ..... | 11 |
+| I.1 Environmental conditions..... | 11 |
+| I.2 Electrical conditions ..... | 11 |
+| I.3 Metrology requirements ..... | 11 |
+| I.4 Test configurations and results..... | 12 |
+| Appendix II – Example of conditions for cooling equipment efficiency testing..... | 13 |
+| II.1 Environmental conditions..... | 13 |
+| II.2 Metrology requirements ..... | 13 |
+| Bibliography..... | 16 |
+
+# Introduction
+
+Typically energy efficiency is defined as the ratio of work output to energy consumed, which in scientific terms can be expressed in the same functional units of joules. As applied to pieces of equipment, the energy efficiency term of work output has transformed to "useful work" or "useful output" to apply to specific items of interest. The energy consumed has also been transformed to units that reflect the primary form or unit of measure tracked to deliver that output, such as electricity or more specifically Watt-hours (Wh). While the measurement of the electricity consumed is generally straightforward, the definition of useful output is context driven and required to be explicit to the application to provide effective measures of monitoring and improvement. In fact, the use of energy efficiency metrics is expressly intended to monitor and drive programmes that gain the most useful output for the energy being consumed. Note that "useful-output" has finite bounds to the context of the application. These bounds may drive categorization methods towards groups such as applications, size, and/or conditions. To apply this concept for the targeted application or equipment, useful work or output must be defined in order to describe the energy efficiency for the subject entity.
+
+For the purposes of this Recommendation, the energy efficiency of the power (delivery and conditioning) equipment will be expressed solely as the ratio of output energy (Watt-hours delivered) to input energy (Watt-hours consumed). This ratio may also be expressed in terms of power (i.e., Watts) if normalized under the condition of use (e.g., root mean square (RMS) over a reasonable application time period). The energy efficiency for air conditioning and air cooling equipment is designated as the ratio of cooling capacity to energy consumed. The cooling capacity is transformed from units of temperature and air/area properties to Watts. Thus for cooling purposes, the ratio is that of cooling capacity in Watts to energy consumed in Watts.
+
+# Recommendation ITU-T L.1320
+
+## Energy efficiency metrics and measurement for power and cooling equipment for telecommunications and data centres
+
+# 1 Scope
+
+This Recommendation specifies principles and concepts of energy efficiency metrics and measurement methods for power feeding equipment and cooling equipment in telecommunications rooms and data centres.
+
+The methodologies defined in this Recommendation are applied at single equipment level. The efficiency of power conversion and cooling in the data centre or telecommunication facility is only partially attributed to the equipment. The architecture and organization of the space and equipment to deliver the power or cooling to the systems is as equal, if not a more significant factor in energy efficiency. Another general factor is the interoperability, management and response of these systems across the demand and operational range.
+
+NOTE – Cooling equipment: In general, data centre level systems should be referred (or normalized) with respect to a full year, in order to take into account the yearly variability of environmental conditions and the consequent possible use of various cooling methods. The reference to a whole year helps to establish a power usage effectiveness (PUE) comparison, especially with respect to an individual data centre.
+
+This Recommendation covers:
+
+- Power feeding equipment:
+ - AC power feeding equipment;
+ - DC power feeding equipment;
+ - Renewable energy equipment1 .
+- Cooling equipment:
+ - Air conditioner equipment;
+ - Outdoor air cooling equipment;
+ - Heat exchanging cooling equipment.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ATIS-0600015.04] ATIS-0600015.04 (2010), *Energy Efficiency for Telecommunication Equipment: Methodology for Measurement and Reporting DC Power Plant – Rectifier Requirements*.
+
+---
+
+1 Renewable energy equipment implies the inclusion of either energy storage (e.g., battery and/or fuel cell) or power from/to the electrical grid. These sources and/or losses in the transmission are outside the scope of this Recommendation but should be taken into account for an overall efficiency assessment.
+
+| | |
+|---------------|---------------------------------------------------------------------------------------------------------------------------------------------|
+| [IEC 61215] | IEC61215 Ed 2.0 (2005), Crystalline silicon terrestrial photovoltaic (PV) modules – Design qualification and type approval. |
+| [IEC 61646] | IEC 61646 Ed.2.0 (2008), Thin-film terrestrial photovoltaic modules – Design qualification and type approval. |
+| [IEC 62040-3] | IEC 62040-3 Ed.2.0 (2011), Uninterruptible power systems (UPS) – Part 3: Method of specifying the performance and test requirements. |
+| [IEC 62108] | IEC 62108 Ed.1.0 (2007), Concentrator photovoltaic (CPV) modules and assemblies – Design qualification and type approval. |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 energy** [b-ISO 16818]: Capacity for doing work; having several forms that may be transformed from one to another, such as thermal (heat), mechanical (work), electrical or chemical and is expressed in Joules. For the purposes of this Recommendation, energy will be expressed in Watt-hours (Wh) or kilo Watt-hours (kWh).
+
+**3.1.2 power** [b-ISO 16818]: Rate at which energy is transmitted.
+
+NOTE 1 – Power is measured in units of Watts.
+
+NOTE 2 – Though the rate of change can be observed as instantaneous values, use of power in these specifications imply normalization based on a reasonable representative period. Typically, energy is measured and a RMS power level is determined.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 alternating power (AC) power feeding equipment:** AC power feeding equipment can be composed of an AC uninterruptible power supply (UPS), a direct current to alternating current (DC/AC) converter and an AC power distribution unit, if considered.
+
+**3.2.2 cooling capacity:** It is the cooling power of air conditioners and refers to the rate that heat is removed from a space. It is most commonly measured as tons per hour or British thermal units (BTUs).
+
+**3.2.3 direct current (DC) power feeding equipment:** DC power feeding equipment can be composed of a rectifier, a direct current to direct current (DC/DC) converter and DC power distribution units, if considered.
+
+**3.2.4 external static pressure:** Static pressure at the air blower exit. High external static pressure is necessary for a cooling system with a raised floor or duct because of the high airflow resistance.
+
+**3.2.5 response time capability:** The level of ability to respond to changes in the conditions in a certain time.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|----------------------|
+| AC | Alternating Current |
+| BTU | British Thermal Unit |
+| CF | Crest Factor |
+
+| | |
+|-----|------------------------------|
+| DC | Direct Current |
+| FC | Fuel Cell |
+| PF | Power Factor |
+| PV | Photovoltaic |
+| RMS | Root Mean Square |
+| UPS | Uninterruptible Power Supply |
+
+# **5 General test methodology**
+
+## **5.1 Power feeding equipment efficiency testing**
+
+### **5.1.1 Conditions for power feeding equipment efficiency testing**
+
+Environmental conditions (such as temperature, humidity and air pressure), electrical conditions (such as input DC voltage, input AC voltage and frequency) and metrology requirements shall be reported when measuring energy efficiency.
+
+Appendix I illustrates an example of how conditions for power feeding equipment efficiency testing should be defined in other domestic or international standards.
+
+Measurement conditions for AC/DC equipment could be considered with reference to [ATIS 0600015.04].
+
+### **5.1.2 Load and environmental conditions**
+
+For test repeatability and consistency, load conditions and test configurations are fixed and static. The test procedures provide mechanisms to test representative points along a load range and across the environmental range. These data points may be representative as long as the load demand range, the environmental range and response requirements are comprehended2 .
+
+On the other hand, dynamic load and the related equipment response are the main factors which influence the overall energy efficiency of the equipment. Therefore it is very important to select the values of different static load and environmental conditions that best represent the dynamic equipment behaviour.
+
+Since the environmental conditions and load vary and are interdependent factors, the dynamic response should be factored into the model. Worst case variance in conditions and response time requirements should be included for the equipment under test.
+
+The individual data points (determined as the other conditions are held fixed) together with the response time capabilities should provide sufficient information to model the environment. These conditions should be documented as part of the data reporting for the individual systems.
+
+The efficiency of the power conversion is dependent on the operating temperature and the load of the system.
+
+NOTE – In fact, efficiency (especially at low load) would be expected to be worse at high temperatures of operation versus low temperature operations. If generic testing is completed at room temperature (~21°C) but
+
+---
+
+2 As with most critical equipment, safety mechanisms to protect operations or equipment beyond the expected operational range should be documented. The equipment reaction or compliance should be evaluated according to those operational failure points as well. These conditions are not described or supported in these evaluation methods, though the safety features may impact the efficiency calculations in the range of operation. As a result, these conditions should be documented as part of the assessment so as to compare similar pieces of equipment.
+
+the facility is set to 35°C, the effective efficiency would be lower than predicted. Therefore test conditions must be carefully set.
+
+### 5.1.3 Power equipment energy efficiency measurements
+
+A general formula for measurement of power feeding equipment energy efficiency based on Figure 1 is shown below.
+
+
+
+```
+graph LR; Pi[Input power (Pi)] --> PFE[Power feeding equipment]; PFE --> Po[Output power (Po)];
+```
+
+Figure 1: General power feeding equipment basic configuration diagram. A central box labeled 'Power feeding equipment' has an input line on the left labeled 'Input power (Pi)' and an output line on the right labeled 'Output power (Po)'. Below the output line is the text 'L 1320(14)\_F01'.
+
+**Figure 1 – General power feeding equipment basic configuration**
+
+$$\eta = P_o / P_i$$
+
+where:
+
+$P_o$ is output power [W]
+
+$P_i$ is input power [W]
+
+This energy efficiency value is measured or calculated from the testing data over a specified time period. The detailed energy efficiency for different types of power feeding equipment is defined below.
+
+Testing configurations require well-defined loads and load conditions. As such, parameters used for static and dynamic load conditions shall be documented. As the load itself may vary based on the conditions and reaction during testing, the load ranges and tolerance during testing should be restricted and documented. The load range shall be consistent with the operational range of the application targeted loads. Given the phase variation in AC sources, power factor correction should also be tested when evaluating the efficiency of the conversion performed by the unit under test.
+
+Monitoring values include other anomalies that dynamically change the power assessments. Monitoring power from AC sources entail considerations such as power factor correction that impact the effective efficiency measurements. Monitoring requires energy (not power) assessments to determine the active power level within a specified time period. In this case the time period used should be consistent with the capacitive load and time scale of the equipment under test and the targeted application. The time period can usually be determined in the control loop parameters of the equipment under test. The remainder of this Recommendation is focused on testing and evaluation of power conversion.
+
+#### 5.1.3.1 AC power feeding equipment
+
+Measurement conditions for UPS shall be considered according to [IEC 62040-3].
+
+##### AC UPS:
+
+
+
+The diagram shows an AC UPS unit connected to a power source on the left and a load on the right. The power source has four lines labeled L1, L2, L3, and N. A 'Power meter' is connected to these lines. On the input side of the AC UPS, there are two 'Voltage testing point' labels and two 'Current probe' labels. On the output side, there are also two 'Voltage testing point' labels and two 'Current probe' labels. The output lines connect to a 'Load' block. The diagram is labeled 'L 1320(14)\_F02' in the bottom right corner.
+
+Figure 2 – AC UPS basic testing configuration diagram
+
+**Figure 2 – AC UPS basic testing configuration**
+
+Figure 2 reports an example of AC UPS basic testing configuration. The measurement point of the voltage should be at the input interface and output interface of the AC UPS. Load could be either linear or non-linear: testing conditions shall therefore define both static and dynamic testing parameters including, e.g., crest factor, frequency and voltage range, etc.
+
+$$\eta_{AC} = P_o / P_i$$
+
+where:
+
+$\eta_{AC}$ is the efficiency of the AC UPS
+
+$P_o$ is the active output power [W]
+
+$P_i$ is the active input power [W]
+
+The $P_i$ and $P_o$ calculation shall be conducted in accordance with [IEC 62040-3].
+
+##### DC/AC inverter:
+
+
+
+The diagram shows a DC/AC inverter unit. On the input side (left), there is a 'Current meter' and a 'Voltage meter' connected to the input lines. A 'Voltage testing point' label is on the input side. On the output side (right), there are two 'Voltage testing point' labels and one 'Current probe' label. The output lines connect to a 'Load' block. Below the inverter, a 'Power meter' is connected to the output lines. The diagram is labeled 'L 1320(14)\_F03' in the bottom right corner.
+
+Figure 3 – DC/AC inverter basic testing configuration diagram
+
+**Figure 3 – DC/AC inverter basic testing configuration**
+
+Figure 3 shows an example of a DC/AC inverter basic testing configuration. The measurement point of the voltage should be at the input interface and output interface of the DC/AC inverter.
+
+$$\eta_{DC/AC} = P_o / P_i$$
+
+where:
+
+$\eta_{DC/AC}$ is efficiency of the DC/AC inverter
+
+$P_o$ is the output active power [W]
+
+$P_i$ is the input DC power [W]
+
+#### 5.1.3.2 DC power equipment
+
+##### AC/DC rectifier:
+
+
+
+The diagram illustrates the basic testing configuration for an AC/DC rectifier. On the left, four AC input lines labeled L1, L2, L3, and N are connected to the AC/DC Rectifier block. A Power meter is connected to these lines. A Current probe is shown on the L1 line. A Voltage testing point is indicated on the N line. The AC/DC Rectifier has a DC output connected to a Load. A Current meter is connected in series with the Load. A Voltage meter is connected in parallel with the Load. A Voltage testing point is indicated on the positive DC output line. The diagram is labeled L 1320(14)\_F04.
+
+Figure 4 – AC/DC rectifier basic testing configuration. The diagram shows an AC/DC Rectifier connected to an AC source (L1, L2, L3, N) and a Load. A Power meter is connected to the AC input. A Current probe is connected to the AC input. A Voltage meter is connected to the AC input. A Voltage testing point is indicated on the AC input. A Current meter is connected to the DC output. A Voltage meter is connected to the DC output. A Voltage testing point is indicated on the DC output.
+
+**Figure 4 – AC/DC rectifier basic testing configuration**
+
+Figure 4 shows an example of an AC/DC rectifier basic testing configuration. The measurement point of the voltage should be at the input interface and output interface of the AC/DC rectifier.
+
+$$\eta_{AC/DC} = P_o / P_i = (V \times I) / P_i$$
+
+where:
+
+$\eta_{AC/DC}$ is the efficiency of the AC/DC rectifier
+
+$P_i$ is the input active power [W]
+
+$P_o$ is the output power [W]
+
+$V$ is output voltage [V]
+
+$I$ is output current [A]
+
+The $P_i$ and $P_o$ calculation could be conducted in accordance with [ATIS 0600015.04].
+
+##### DC/DC converter:
+
+
+
+The diagram illustrates the basic testing configuration for a DC/DC converter. On the left, an input source is connected to the DC/DC converter block. A Current meter and a Voltage meter are connected to the input. A Voltage testing point is indicated on the input line. The DC/DC converter has an output connected to a Load. A Current meter and a Voltage meter are connected to the output. A Voltage testing point is indicated on the output line. The diagram is labeled L 1320(14)\_F05.
+
+Figure 5 – DC/DC converter basic testing configuration. The diagram shows a DC/DC converter connected to an input source and a Load. A Current meter and a Voltage meter are connected to the input. A Voltage testing point is indicated on the input. The DC/DC converter has an output connected to a Load. A Current meter and a Voltage meter are connected to the output. A Voltage testing point is indicated on the output.
+
+**Figure 5 – DC/DC converter basic testing configuration**
+
+Figure 5 shows an example of a DC/DC converter basic testing configuration. The measurement point of the voltage should be at the input interface and output interface of the DC/DC converter.
+
+$$\eta_{DC/DC} = P_o / P_i = (V_o \times I_o) / (V_i \times I_i)$$
+
+where:
+
+$\eta_{DC/DC}$ is the efficiency of the DC/DC converter
+
+$P_i$ is the input power [W]
+ $P_o$ is the output power [W]
+ $V_o$ is the output voltage [V]
+ $I_o$ is the output current [A]
+ $V_i$ is the input voltage [V]
+ $I_i$ is the input current [A]
+
+#### 5.1.3.3 Renewable energy equipment
+
+##### Photovoltaic (PV) panel efficiency
+
+$$\eta_{PV} = P_o / P_i = (V \times I) / (I_r \times S)$$
+
+where:
+
+$\eta_{PV}$ is the efficiency of the PV panel
+ $P_i$ is the input power [W]
+ $P_o$ is the output power [W]
+ $V$ is the output voltage [V]
+ $I$ is the output current [A]
+ $I_r$ is irradiance
+ $S$ is the squire of the PV arrays
+
+Environmental conditions (e.g., irradiance, ambient temperature, etc.) shall be compliant with [IEC 61215] and [IEC 61646].
+
+##### Wind turbine energy efficiency:
+
+$$\eta_W = P_o / P_i = (V \times I) / (1/2 \rho S v^3)$$
+
+where:
+
+$\eta_W$ is the efficiency of the wind turbine
+ $P_i$ is the input power [W]
+ $P_o$ is the output power [W]
+ $V$ is the output voltage [V]
+ $I$ is the output current [A]
+ $\rho$ is the air density
+ $S$ is the wind wheel sweeping area
+ $v$ is the wind speed
+
+##### Hydrogen fuel cell (FC) stack efficiency:
+
+$$\eta_F = P_o / P_i = (V_o \times I_o) / (m_{H_2} \times LHV_{H_2}) \times 100\%$$
+
+where:
+
+$\eta_F$ is the efficiency of the fuel cell stack
+ $m_{H_2}$ is the hydrogen flow rate [g/s]
+ $LHV_{H_2}$ is the hydrogen low heat value [J/g]
+
+## 5.2 Cooling equipment efficiency testing
+
+### 5.2.1 Conditions for cooling equipment efficiency testing
+
+Environmental conditions (such as temperature, humidity, air pressure and external static pressure) and metrology requirements shall be reported when measuring energy efficiency. Measurement of cooling equipment efficiency should be conducted under multiple conditions of outside temperature and humidity to consider the annual performance.
+
+Appendix II provides some information on conditions for cooling equipment efficiency testing defined in other domestic or international standards.
+
+### 5.2.2 Cooling equipment efficiency measurement
+
+#### 5.2.2.1 Air conditioner
+
+Figure 6 shows an example of the air conditioner equipment basic testing configuration
+
+
+
+The diagram illustrates the basic testing configuration for an air conditioner. It consists of two main areas: an 'Indoor unit testing room' and an 'Outdoor unit testing room'. The indoor unit is connected to the outdoor unit via a duct system. The indoor unit is placed within a large rectangular room. To its left, there is a section for 'Air flow testing equipment'. To its right, there are two 'Temperature and humidity testing equipment' units. The outdoor unit is located in a separate, dashed rectangular room. The entire setup is labeled 'L.1320(14)\_F06' at the bottom right.
+
+Diagram of air conditioner equipment basic testing configuration showing indoor and outdoor unit testing rooms.
+
+Figure 6 – Air conditioner equipment basic testing configuration
+
+$$\eta_{air} = Q_T / P_i$$
+
+where:
+
+$\eta_{air}$ is the efficiency of the air conditioner
+
+$$Q_T = Q_S + Q_L$$
+
+$$Q_S = C_p \times \rho \times L \times \Delta T$$
+
+$$Q_L = K \times \rho \times L \times (W_1 - W_2)$$
+
+$$L = S \times V$$
+
+$P_i$ is the input power [W]
+
+$S$ is the exhaust area of the outdoor air unit [m2 ]
+
+$V$ is the outdoor air unit wind speed [m/s]
+
+$Q_S$ is the sensible cooling capacity [W]
+
+$Q_L$ is latent cooling capacity [W]
+
+$C_p$ is specific heat of the air [J/kg°C]
+
+$\rho$ is air density [kg/m3 ]
+
+$L$ is the total room air volume [m3 /s]
+
+$\Delta T$ is the temperature difference between inside and outside the room [°C]
+
+$W_1$ is the initial water content of the air [kg/kg]
+
+$W_2$ is the final water content of the air [kg/kg]
+
+$K$ is the latent heat of vaporization water [J /kg]
+
+#### 5.2.2.2 Outdoor air cooling equipment
+
+Figure 7 shows an example of the outdoor air cooling equipment basic testing configuration.
+
+
+
+Diagram of outdoor air cooling equipment basic testing configuration. It shows two rooms: an 'Indoor unit testing room' on the left and an 'Outdoor unit testing room' on the right, separated by a dashed line. Inside the indoor room, there is 'Air flow testing equipment' and 'Temperature and humidity testing equipment'. The 'Outdoor air cooling equipment under test' is positioned in the center, straddling the boundary between the two rooms. Inside the outdoor room, there is also 'Temperature and humidity testing equipment'. A small label 'L1320(14)\_F07' is at the bottom right.
+
+Figure 7 – Outdoor air cooling equipment basic testing configuration
+
+$$\eta_{oair} = Q_S / P_i$$
+
+where:
+
+$\eta_{oair}$ is the efficiency of the outdoor air conditioner
+
+$$Q_T = Q_S + Q_L$$
+
+$$Q_S = C_p \times \rho \times L \times \Delta T$$
+
+$$Q_L = K \times \rho \times L \times (W_1 - W_2)$$
+
+$$L = S \times V$$
+
+$P_i$ is the input power [W]
+
+$V$ is the outdoor air cooling equipment wind speed [m/s]
+
+$S$ is the exhaust area of the outdoor air cooling equipment [m2 ]
+
+$Q_S$ is the sensible cooling capacity [W]
+
+$C_p$ is the specific heat of air [J /kg°C]
+
+$\rho$ is the air density [kg/m3 ]
+
+$L$ is the total room air volume [m3 /s]
+
+$\Delta T$ is the temperature difference between inside and outside the room [°C]
+
+$W_1$ is the initial water content of the air [kg/kg]
+
+$W_2$ is the final water content of the air [kg/kg]
+
+$K$ is the latent heat of vaporization water [J /kg]
+
+#### 5.2.2.3 Heat exchanging cooling equipment
+
+Figure 8 shows an example of the heat exchanging cooling equipment basic testing configuration.
+
+
+
+Figure 8 – Heat exchanging cooling equipment basic testing configuration. The diagram shows two rooms: an 'Indoor unit testing room' on the left and an 'Outdoor unit testing room' on the right, separated by a dashed line. Inside the indoor room, there is 'Air flow testing equipment' and 'Temperature and humidity testing equipment'. The 'Heat exchanging cooling equipment under test' is positioned in the center, straddling the boundary between the two rooms. Inside the outdoor room, there is also 'Temperature and humidity testing equipment'. A label 'L1320(14)\_F08' is at the bottom right.
+
+**Figure 8 – Heat exchanging cooling equipment basic testing configuration**
+
+$$\eta_{he} = Q_S / P_i$$
+
+where:
+
+$\eta_{he}$ is the efficiency of heat exchanging cooling equipment
+
+$$Q_T = Q_S + Q_L$$
+
+$$Q_S = C_p \times \rho \times L \times \Delta T \times \eta_e$$
+
+$$Q_L = K \times \rho \times L \times (W_1 - W_2)$$
+
+$$L = S \times V$$
+
+$P_i$ is input power [W]
+
+$V$ is the outdoor air cooling equipment wind speed [m/s]
+
+$S$ is the exhaust area of the outdoor air cooling equipment [ $\text{m}^2$ ]
+
+$Q_S$ is the sensible cooling capacity [W]
+
+$C_p$ is the specific heat of air [ $\text{J/kg}^\circ\text{C}$ ]
+
+$\rho$ is the air density [ $\text{kg/m}^3$ ]
+
+$L$ is the total room air volume [ $\text{m}^3/\text{s}$ ]
+
+$\Delta T$ is the temperature difference between inside and outside the room [ $^\circ\text{C}$ ]
+
+$W_1$ is the initial water content of the air [ $\text{kg/kg}$ ]
+
+$W_2$ is the final water content of the air [ $\text{kg/kg}$ ]
+
+$K$ is the latent heat of vaporization water [ $\text{J/kg}$ ]
+
+$\eta_e$ is the efficiency of the core heat exchanger
+
+Appendix II describes specific examples of load conditions.
+
+# Appendix I
+
+## Example of conditions for power feeding equipment efficiency testing
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### I.1 Environmental conditions
+
+#### Temperature
+
+A power feeding equipment testing configuration was evaluated at standard temperature test conditions, which was a temperature within the range of $25^{\circ} \pm 3^{\circ}\text{C}$ [b-ATIS-0600015]. The difference in temperature has an influence on test results; see Figure I.1 for more detailed information. The equipment itself was offline or operated at this ambient temperature for no less than three hours prior to the test. No ambient temperature changes were allowed until the test was complete and the temperature of the equipment was stable.
+
+For some types of equipment, additional measurement at its rated temperature boundaries could be required to also test the energy efficiency at the limits of its operating temperature, as indicated in the detailed product specific requirements.
+
+#### Humidity
+
+For power feeding equipment, the equipment was evaluated at a relative humidity within the range (30%-75%) [b-ATIS-0600015].
+
+#### Air pressure
+
+The equipment was evaluated at site air pressure within the range (81 200 pa-102 000 pa) [b-ATIS-0600015]. No targeted airflows were allowed.
+
+### I.2 Electrical conditions
+
+#### Input AC voltage and frequency
+
+The input to the power feeding equipment (all active feeds) was at a nominal specified voltage $\pm 1\%$ and the specified frequency is $\pm 1\%$ . In the case where the equipment can work at a different nominal voltage, the measurement should be repeated at any nominal voltage, e.g., equipment declared able to work at 110V, 220V and 230V should be tested at each of these voltages.
+
+## I.3 Metrology requirements
+
+Every active power feed had the power (current) meter [b-ATIS-0600015] installed in the power line with a desired accuracy not less than $\pm 1\%$ [b-ATIS-0600015] of the actual power consumption. All energy consumption calculations were based on averaging multiple readings over the course of measurements. Power meters were able to produce not less than 100 evenly-space readings in every full test cycle duration.
+
+All measurement instruments used were calibrated by a counterpart national metrology institute and within a calibration due date and the measurement tolerances were within $\pm 1\%$ :
+
+- Power source: Power sources used to provide power to the equipment under test were capable of providing a minimum of 1.5 times [b-ATIS-0600015] the power rating of the equipment under test.
+
+- Power measurement instrument: The power measurement instrument (such as voltmeter and ampere meter or power analyser) had a resolution of 0.5%. The power measurement instrument had the following minimum characteristics:
+ - a minimum digitizing sample rate of 40 kHz,
+ - input circuitry with a minimum bandwidth of 80 kHz,
+ - ability to log data over time and store the total measurement period and
+ - overall measurement accuracy within $\pm 1\%$ .
+
+## I.4 Test configurations and results
+
+UPS testing equipment connection methods are shown in Figure I.1.
+
+
+
+Figure I.1: UPS testing configurations. A photograph of the internal wiring and terminals of a UPS unit under test. Four callout boxes with arrows identify key components: 'UPS output terminal voltage sensors' points to small wires connected to the output bus; 'UPS input terminal voltage sensors' points to similar wires on the input side; 'UPS output terminal' points to the main output cable connections; and 'UPS input terminal' points to the main input cable connections. The unit is mounted on a wooden pallet.
+
+L.1320(14)\_FI.1
+
+**Figure I.1 – UPS testing configurations**
+
+A UPS whose output capacity is 100 kVA is tested in this example.
+
+If the power meter has enough channels, the efficiency can be read directly from the test equipment, if this is not the case, two or more power meters can be connected. The result is calculated from data read synchronously from the several power meters. Throughout the testing period, the load is constant and without variation.
+
+Test results are shown in Table I.1.
+
+**Table I.1 – UPS test results in different test conditions**
+
+| | 25% | 50% | 75% | 100% |
+|------------------------|-------------------------|-------------------------|-------------------------|-------------------------|
+| Linear load | 22.84/24.14 = 94.56% | 46.31/48.35 = 95.78% | 68.56/71.68 = 95.67% | 89.18/93.64 = 95.24% |
+| Non-linear load CF = 2 | | 48.99/51.22 = 95.66% | | 85.05/89.10 = 95.31% |
+| Non-linear load CF = 3 | 16.33/17.55 = 93.02% | 32.25/34.15 = 94.43% | 47.38/50.18 = 94.42% | 63.07/67.02 = 94.01% |
+
+# Appendix II
+
+## Example of conditions for cooling equipment efficiency testing
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Appendix II describes specific examples of cooling equipment efficiency testing and test configurations.
+
+### II.1 Environmental conditions
+
+#### Temperature and humidity
+
+For cooling equipment, the testing condition considered constant outdoor temperature and room temperature. For the air conditioner, the room temperature was $(24\pm 1)^\circ\text{C}$ (dry bulb) and $(16\pm 0.5)^\circ\text{C}$ (wet bulb), and the outdoor temperature was $(35\pm 1)^\circ\text{C}$ (dry bulb) and $(24\pm 0.5)^\circ\text{C}$ (wet bulb). No ambient temperature changes were allowed until the test was complete.
+
+#### Air pressure
+
+The equipment was evaluated at site pressure in the range of 86 000 pa to 106 000 pa. No targeted airflows were allowed.
+
+### II.2 Metrology requirements
+
+All measurement instruments used were calibrated by the counterpart national metrology institute and within the calibration due date and the measurement tolerance was within $\pm 1\%$ :
+
+- Power measurement instrument: The power measurement instrument (such as voltmeter and ampere meter or power analyser) had an accuracy of 0.5% or better.
+- Temperature measurement instruments: Temperature measurement instruments (such as a mercury glass thermometer or an electronic thermometer) had an accuracy of 0.1% or better.
+- Anemometer: An Anemometer (such as a dry or wet bulb anemometer) had an accuracy of 0.1% or better.
+- Air flow tester: An air flow tester had an accuracy of 0.1% or better.
+
+### Test conditions and results
+
+An air conditioner indoor unit and outdoor unit testing configurations are shown in Figures II.1 and II.2.
+
+
+
+A photograph showing the indoor unit of an air conditioner in a testing environment. The unit is a large, white, rectangular box mounted on a metal frame. A blue callout box with the text "Air conditioner indoor unit" points to the main unit. Another blue callout box with the text "Temperature and humidity sensor" points to a small sensor device mounted on the unit's side.
+
+Air conditioner indoor unit testing setup with labels for the unit and a sensor.
+
+L.1320(14)\_FII.1
+
+**Figure II.1 – Air conditioner indoor unit testing**
+
+
+
+A photograph showing the outdoor unit of an air conditioner in a testing environment. The unit is a white, rectangular box with a large fan on its side, mounted on a wooden pallet. A blue callout box with the text "Temperature and humidity sensor" points to a sensor device mounted on the unit's top surface. Another blue callout box with the text "Air conditioner outdoor unit" points to the main unit.
+
+Air conditioner outdoor unit testing setup with labels for the unit and a sensor.
+
+L.1320(14)\_FII.2
+
+**Figure II.2 – Air conditioner outdoor unit testing**
+
+An air conditioner whose output total cooling capacity is 100 kW was tested in this example. The input electrical energy and output cooling power were tested synchronously and the indoor air testing room and outdoor air testing room conditions (including temperature and humidity) were constant during whole testing process. In addition, as the testing result is influenced by ambient temperature and humidity, it was tested in the condition listed in this appendix. If the test conditions are different, the result will be completely different. Test results are shown in Table II.1.
+
+**Table II.1 – Cooling equipment test results in different test conditions**
+
+| Item | Value |
+|------------------------------|-------------------------|
+| Room dry bulb temperature | 24.04°C |
+| Room wet bulb temperature | 16.35°C |
+| Outdoor dry bulb temperature | 34.97°C |
+| Outdoor wet bulb temperature | 24.22°C |
+| Air pressure | 104.582 kPa |
+| External static pressure | 41 Pa |
+| Phase A voltage | 218.18 V |
+| Phase B voltage | 218.51 V |
+| Phase C voltage | 219.50 V |
+| Phase A frequency | 50.00 Hz |
+| Phase B frequency | 50.00 Hz |
+| Phase C frequency | 50.00 Hz |
+| Input power | 32.32 kW |
+| Total room air volume | 25613 m 3 /h |
+| QS | 90.01 kW |
+| QT | 98.24 kW |
+| $\eta_{air}$ | 3.04 |
+
+# Bibliography
+
+- [b-ANSI/TIA 942] ANSI/TIA 942-2005, *Telecommunications Infrastructure Standard for Data Centers*.
+- [b-ATIS-0600015] ANSI ATIS0600015-2013, *Energy efficiency for telecommunication equipment: Methodology for measurement and reporting – General requirements*.
+- [b-ETSI TR 102 489] ETSI TR 102 489 V1.3.1 (2013), *Environmental Engineering (EE); European telecommunications standard for equipment practice; Thermal Management Guidance for equipment and its deployment*.
+- [b-ISO 13253] ISO 13253:2011, *Ducted air-conditioners and air-to-air heat pumps – Testing and rating for performance*.
+- [b-ISO/IEC 17025] ISO/IEC 17025:2005, *General requirements for the competence of testing and calibration laboratories*.
+- [b-ISO 16818] ISO 16818:2008, *Building environment design – Energy efficiency – Terminology*.
+- [b-ISO 5151] ISO 5151:2010, *Non-ducted air conditioners and heat pumps – Testing and rating for performance*.
+- [b-ASHRAE] ASHRAE 127 (2012), *Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners*.
+- [b-CCSA-YD/T 1968] CCSA-YD/T 1968 (2009), *Intelligent Heat Exchanger for Telecommunication Stations/Sites*.
+- [b-CCSA-YD/T 1969] CCSA-YD/T 1969 (2009), *Intelligent Energy Saving System by Fresh Air for Telecommunication Stations/Sites*.
+- [b-EPRI/ecova] EPRI/ecova Revision 6.6 (2012), *Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac-Dc and Dc-Dc Power Supplies*.
+[http://www.pluginloadsolutions.com/docs/collatrl/print/Generalized\\_Internal\\_Power\\_Supply\\_Efficiency\\_Test\\_Protocol\\_R6.6.pdf](http://www.pluginloadsolutions.com/docs/collatrl/print/Generalized_Internal_Power_Supply_Efficiency_Test_Protocol_R6.6.pdf)
+- [b-greengrid] [www.thegreengrid.org](http://www.thegreengrid.org)
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1330-201503-I_PDF-E/raw.md b/marked/L/T-REC-L.1330-201503-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..ff7941e868f6407975e446e6bc83b16201b6782c
--- /dev/null
+++ b/marked/L/T-REC-L.1330-201503-I_PDF-E/raw.md
@@ -0,0 +1,1161 @@
+
+
+International Telecommunication Union
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1330**
+
+(03/2015)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Energy efficiency measurement and metrics for
+telecommunication networks**
+
+Recommendation ITU-T L.1330
+
+ITU-T
+
+
+
+The logo of the International Telecommunication Union (ITU) features a globe with a red lightning bolt striking it, symbolizing telecommunications. To the right of the globe, the text "International Telecommunication Union" is written in blue, with the acronym "ITU" in a larger, bold blue font.
+
+ITU logo
+
+International
+Telecommunication
+Union
+
+
+
+# Recommendation ITU-T L.1330
+
+# Energy efficiency measurement and metrics for telecommunication networks
+
+## Summary
+
+Recommendation ITU-T L.1330 provides a set of metrics for the assessment of energy efficiency (EE) of telecommunication (TLC) mobile networks, together with proper measurement methods. Such metrics are of extremely high importance to operators, given that the optimization of the energy performance of a single piece of equipment does not guarantee the overall maximum energy efficiency of a complex network formed by several interconnected equipments. Hence, through the metrics reported in this Recommendation, a better comprehension of network energy efficiency will be gained, not only for "total" networks, but also for "partial" networks, definable through either geographic or demographic boundaries.
+
+In a future step, energy efficiency of TLC fixed networks will be provided.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1330 | 2015-03-01 | 5 | 11.1002/1000/12430 |
+
+## Keywords
+
+Energy efficiency, metrics, networks.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|---------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 3.1 Terms defined elsewhere ..... | 2 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 3 |
+| 5 Conventions ..... | 4 |
+| 6 Network under test definition ..... | 5 |
+| 6.1 Introduction ..... | 5 |
+| 6.2 Test parameter categorization..... | 6 |
+| 6.3 Network classification ..... | 7 |
+| 7 Metrics for energy efficiency assessment..... | 9 |
+| 7.1 Energy consumption metrics ..... | 9 |
+| 7.2 Performance metrics ..... | 10 |
+| 7.3 Mobile network energy efficiency metrics..... | 10 |
+| 8 Measurement of energy efficiency ..... | 11 |
+| 8.1 Time duration of the measurement..... | 11 |
+| 8.2 Measurement procedures ..... | 11 |
+| 9 Extrapolation for overall networks ..... | 14 |
+| 9.1 Extrapolation method ..... | 15 |
+| 9.2 Extrapolation reporting tables ..... | 16 |
+| 10 Assessment report..... | 18 |
+| 10.1 Report of network area under test ..... | 18 |
+| 10.2 Report of sites under test ..... | 20 |
+| 10.3 Report of site measurement ..... | 21 |
+| 11 Implementation guidelines..... | 22 |
+| Appendix I – Implementation examples ..... | 23 |
+| Bibliography..... | 29 |
+
+# **Introduction**
+
+Recommendation ITU-T L.1330 provides a set of metrics for the assessment of energy efficiency (EE) of telecommunication (TLC) mobile networks, together with proper measurement methods. Such metrics are of extremely high importance to operators, given that the optimization of the energy performance of a single piece of equipment does not guarantee the overall maximum energy efficiency of a complex network formed by several interconnected equipments. Hence, through the metrics reported in this Recommendation, a better comprehension of network energy efficiency will be gained, not only for "total" networks, but also for "partial" networks, definable through either geographic or demographic boundaries.
+
+This Recommendation was developed jointly by ETSI TC EE and ITU-T Study Group 5 and published respectively by ITU and ETSI as Recommendation ITU-T L.1330 and ETSI Standard ETSI ES 203 228, which are technically equivalent.
+
+## Recommendation ITU-T L.1330
+
+## Energy efficiency measurement and metrics for telecommunication networks
+
+# 1 Scope
+
+This Recommendation aims to define the topology and level of analysis necessary to assess the energy efficiency (EE) of mobile networks. Within the scope of this Recommendation are the radio access parts of the mobile network, namely: radio base stations, backhauling systems, radio controllers and other infrastructure radio site equipment. The technologies covered are: global system for mobile communications (GSM), universal mobile telecommunications communications (UMTS) and long-term evolution (LTE) (including LTE advanced (LTE-A)). In particular, this Recommendation defines metrics for mobile network energy efficiency and methods for assessing (and measuring) energy efficiency in operational networks. The purpose of this specification is to allow better comprehension of network energy efficiency.
+
+This Recommendation deals with both homogeneous and heterogeneous "networks" and considers networks whose size and scale could be defined by topologic, geographic or demographic boundaries. For networks defined by topologic boundaries, a possible example of a network consists of a control node (whenever applicable), its supported access nodes, as well as its related network elements. Networks could also be defined by geographic boundaries, such as citywide, national or continental networks or by demographic boundaries, such as urban or rural networks.
+
+This specification applies to the so-called "partial" networks where energy efficiency is measured in a standardized way. This specification extends the measurements in partial networks to wider so-called "total" network energy efficiency estimations (e.g., the network in a geographic area, the network in an entire country, the network of a mobile network operator (MNO)).
+
+Terminal (end-user) equipment is outside the scope of this Recommendation and thus, is not considered in the energy efficiency measurement.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T L.1310] Recommendation ITU-T L.1310 (2014), *Energy efficiency metrics and measurement methods for telecommunication equipment*.
+- [ETSI TS 123 203] ETSI TS 123 203 V12.6.0 (2014), *Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); LTE; Policy and charging control architecture (3GPP TS 23.203 version 12.6.0 Release 12)*.
+- [ETSI TS 125 104] ETSI TS 125 104 V12.4.0 (2014), *Universal Mobile Telecommunications System (UMTS); Base Station (BS) radio transmission and reception (FDD) (3GPP TS 25.104)*.
+- [ETSI TS 132 405] ETSI TS 132 405 V12.0.0 (2014), *Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); LTE; Telecommunication management; Performance Management (PM)*.
+
+*Performance measurements; Universal Terrestrial Radio Access Network (UTRAN) (3GPP TS 32.405 version 12.0.0 Release 12).*
+
+- [ETSI TS 132 412] ETSI TS 132 412 V12.0.0 (2014), *Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); LTE; Telecommunication management; Performance Management (PM) Integration Reference Point (IRP): Information Service (IS) (3GPP TS 32.412 version 12.0.0 Release 12).*
+- [ETSI TS 132 425] ETSI TS 132 425 V12.0.0 (2014), *LTE; Telecommunication management; Performance Management (PM); Performance measurements Evolved Universal Terrestrial Radio Access Network (E-UTRAN) (3GPP TS 32.425 version 12.0.0 Release 12).*
+- [ETSI TS 136 104] ETSI TS 136 104 V12.5.0 (2014), *LTE; Evolved Universal Terrestrial Radio Access (E-UTRA); Base Station (BS) radio transmission and reception (3GPP TS 36.104 version 12.5.0 Release 12).*
+- [ETSI TS 136 314] ETSI TS 136 314 V12.0.0 (2014), *LTE; Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Layer 2 – Measurements (3GPP TS 36.314 version 12.0.0 Release 12).*
+- [ETSI TS 152 402] ETSI TS 152 402 V11.0.0 (2012), *Digital cellular telecommunications system (Phase 2+); Telecommunication management; Performance Management (PM); Performance measurements – GSM (3GPP TS 52.402 version 11.0.0 Release 11).*
+- [ISO/IEC 17025] ISO/IEC 17025 (2005), *General requirements for the competence of testing and calibration laboratories.*
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 backhaul equipment:** Equipment used to connect base stations (BSs) to the core network, or to other BSs (such as X2 in LTE).
+
+**3.2.2 base station (BS):** A generic term used for a network component which serves one or more cells and interfaces the user terminal (through air interface) and a radio access network infrastructure.
+
+**3.2.3 distributed RBS:** A radio BS (RBS) architecture which contains remote radio heads (RRHs) close to the antenna element and a central element connecting BS to network infrastructure.
+
+**3.2.4 energy:** Capacity for doing work; having several forms that may be transformed from one to another, such as thermal (heat), mechanical (work), electrical or chemical, expressed in Joules. For the purpose of this Recommendation, energy will be expressed in Watt-hours (Wh) or kilo Watt-hours (kWh).
+
+**3.2.5 energy efficiency (EE):** The relation between the useful output and energy/power consumption.
+
+**3.2.6 energy saving feature:** A feature which contributes to decreasing energy consumption as compared to the case when the feature is not implemented.
+
+**3.2.7 integrated BS:** A BS architecture in which all BS elements are located close to one another for example in one or two cabinets.
+
+NOTE – The integrated BS architecture may include tower mount amplifier (TMA) close to antenna.
+
+**3.2.8 mobile network (MN):** A set of equipment from the radio access network or subnetwork that are relevant for the assessment of energy efficiency.
+
+**3.2.9 mobile network coverage energy efficiency:** The ratio between the area covered by the network in the mobile network under investigation and the energy consumption.
+
+**3.2.10 mobile network data energy efficiency:** The ratio between the performance indicator based on data volume and the energy consumption when assessed during the same time frame.
+
+**3.2.11 mobile network energy consumption:** The overall energy consumption of equipment included in the MN under investigation.
+
+**3.2.12 mobile network energy efficiency:** The energy efficiency of a mobile network.
+
+**3.2.13 mobile network operator (MNO):** An operator that manages one or more mobile networks.
+
+**3.2.14 mobile network operator penetration ratio:** The percentage of traffic served by a mobile network operator in the area where it is active.
+
+**3.2.15 mobile network performance delivered:** The performance indicator of the MN under investigation, defined as the data volume delivered by the mobile network under investigation during the time frame of the energy consumption assessment.
+
+**3.2.16 power:** The rate at which energy is transmitted. Power is measured in units of Watts.
+
+**3.2.17 power consumption:** The power consumed by a device needed to achieve an intended application performance.
+
+**3.2.18 radio access network:** A telecommunication network in which the access to the network (connection between user terminal and network) is implemented without the use of wires and is part of GSM/EDGE radio access network (GERAN), UMTS terrestrial radio access network (UTRAN) or evolved UMTS terrestrial radio access network (E-UTRA) networks defined by 3rd Generation Partnership Project (3GPP).
+
+**3.2.19 telecommunication network:** A network operated under a license granted by a national telecommunications authority, which provides telecommunications between network termination points (NTPs).
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|------------------------------------|
+| 3GPP | 3rd Generation Partnership Project |
+| BS | Base Station |
+| BH | Backhaul |
+| CoA | Coverage Area |
+| CR | Coverage Ratio |
+| CS | Circuit Switched |
+| DCA | Designed Coverage Area |
+| DP | Dominant Penetration |
+| DU | Dense Urban |
+| DV | Data Volume |
+
+| | |
+|-------|------------------------------------------|
+| ECA | Effective Coverage Area |
+| EDGE | Enhanced Data rate GSM Evolution |
+| EE | Energy Efficiency |
+| FAO | Food and Agriculture Organization |
+| GSM | Global System for Mobile communication |
+| LTE | Long Term Evolution |
+| MDT | Minimization of Drive Tests |
+| MN | Mobile Network |
+| MNO | Mobile Network Operator |
+| MP | Minor Penetration |
+| NDP | Non-Dominant Penetration |
+| O&M | Operation and Maintenance |
+| PS | Packet Switched |
+| PSL | Packet Switched Large packets dominating |
+| PSS | Packet Switched Small packets dominating |
+| QoS | Quality of Service |
+| RAB | Radio Access Bearer |
+| RAN | Radio Access Network |
+| RAT | Radio Access Technology |
+| RC | Radio Controller |
+| RRC | Radio Resource Control |
+| RRH | Remote Radio Head |
+| RU | Rural |
+| SCH | Signalling Channel |
+| SINR | Signal to Interference plus Noise Ratio |
+| SU | Suburban |
+| SW | Software |
+| TCH | Traffic Channel |
+| U | Urban |
+| UE | User Equipment |
+| UTRAN | UMTS Terrestrial Radio Access Network |
+
+# 5 Conventions
+
+None.
+
+# 6 Network under test definition
+
+## 6.1 Introduction
+
+The mobile radio access network under investigation shall include all the equipment necessary to run a radio access network (RAN) or subnetwork. Equipment to be included in the mobile network (MN) under investigation follows:
+
+- base stations (BSs) (see [ETSI TS 125 104], [ETSI TS 136 104]);
+ - wide area BS;
+ - medium range BS;
+ - local area BS;
+ - home BS.
+
+NOTE – Home BSs (and WiFi access points) are not dealt with in this Recommendation version, but are being considered for a future version.
+
+- site equipment (e.g., air conditioners, rectifiers/batteries, fixed network equipment);
+- backhaul (BH) equipment required to interconnect the BS used in the assessment with the core network;
+- radio controller (RC).
+
+Power consumption and energy efficiency (EE) measurements of individual mobile network elements are described in several standards (e.g., [ITU-T L.1310] for radio base stations). This Recommendation however, describes energy consumption and MN energy efficiency measurements in operational networks.
+
+As a complete and detailed energy consumption measurement of the entire network of a country or mobile network operator (MNO) is, in most cases, impossible or economically not viable, the total network is split into a small number of networks with limited size (i.e., "subnetworks").
+
+These subnetworks are defined to represent some specific characteristics, for example:
+
+- capacity limited networks representing urban (U) and dense urban (DU) networks;
+- suburban (SU) networks with high requirements for coverage and capacity;
+- rural (RU) networks, which are usually coverage limited.
+
+The size and scale of the subnetworks are defined by topologic, geographic or demographic boundaries. For networks defined by topologic boundaries, a possible example of a network covered by this Recommendation consists of a radio controller (whenever applicable), its supported access nodes as well as the related network elements. Networks could be defined by geographic boundaries, such as citywide, national or continental networks or could be defined by demographic boundaries, such as urban or rural networks.
+
+The subnetworks analysed might consist of macro-only base stations, heterogeneous networks or what is actually implemented in real networks.
+
+The tests defined in this Recommendation for subnetworks provide the basis to estimate energy efficiency for large networks of one MNO or within an entire country, applying the extrapolation methods described in clause 9. The network under test definition is reported in Figure 1.
+
+
+
+```
+
+graph TD
+ RC1[RC] -.-> BE1[Backhaul equipment]
+ RC1 -.-> BE2[Backhaul equipment]
+ RC1 -.-> BE3[Backhaul equipment]
+ RC2[RC] -.-> BE3
+ BE1 -.-> S1[Site wide area BS]
+ BE2 -.-> S2[Site wide area BS]
+ BE3 -.-> MRBS1[Medium range BS]
+ BE3 -.-> MRBS2[Medium range BS]
+ BE3 -.-> S3[Site wide area BS]
+ S1 -.-> BS1[Base station]
+ S1 -.-> SE1[Site equipment]
+ S2 -.-> BS2[Base station]
+ S2 -.-> SE2[Site equipment]
+ S3 -.-> BS3[Base station]
+ S3 -.-> SE3[Site equipment]
+ S1 -.-> LABS1[Local area BS]
+ S1 -.-> LABS2[Local area BS]
+ S2 -.-> LABS3[Local area BS]
+ S2 -.-> LABS4[Local area BS]
+ S3 -.-> LABS5[Local area BS]
+ S3 -.-> LABS6[Local area BS]
+
+```
+
+Figure 1 – Network under test definition. A hierarchical diagram showing the network structure. At the top are two 'RC' (Radio Controller) nodes. Below them are three 'Backhaul equipment' nodes. The left 'Backhaul equipment' connects to a 'Site (wide area BS)' containing 'Base station' and 'Site equipment'. The middle 'Backhaul equipment' connects to another 'Site (wide area BS)' containing 'Base station' and 'Site equipment'. The right 'Backhaul equipment' connects to two 'Medium range BS' nodes and a 'Site (wide area BS)' containing 'Base station' and 'Site equipment'. Below the left 'Site (wide area BS)' are two 'Local area BS' nodes. Below the middle 'Site (wide area BS)' are two 'Local area BS' nodes. Below the right 'Site (wide area BS)' are two 'Local area BS' nodes. Dashed lines indicate connections between nodes.
+
+L.1330(15)\_F01
+
+**Figure 1 – Network under test definition**
+
+## 6.2 Test parameter categorization
+
+Metrics used for the energy efficiency assessment of an MN require the definition and collection of a range of parameters and variables. These are separated into two categories:
+
+- 1) parameters and variables required to calculate the network energy efficiency;
+- 2) parameters needed to allow network energy efficiency evaluation.
+
+The first category describes a set of network variables as described in clause 7 (i.e., energy consumption, delivered bits, coverage) to be used to calculate the energy efficiency.
+
+The second category includes parameters that are not directly required in the energy efficiency calculation. These parameters describe the network characteristics, such as geographical conditions, population density, coverage area (CoA), targeted data rates, climate zones, etc., and are used to interpolate from the measured subnetwork to a larger network as described in clause 9. These parameters can be used to interpret variations in energy efficiency results of different networks. Table 1 reports the test parameter categorization.
+
+**Table 1 – Test parameter categorization**
+
+| Category | Parameter | Remarks |
+|----------|---------------------|---------------------------------------------------------------------------------------------------------|
+| 1 | EC MN | Measured network energy consumption |
+| 1 | Capacity | As defined in clause 7.2 |
+| 1 | Coverage area | As defined in clause 8.2.3 |
+| 2 | Coverage ratio | As defined in clause 8.2.3 |
+| 2 | Demography | Population density as defined in clause 6.3.1 |
+| 2 | Topography | As defined in clause 6.3.2 |
+| 2 | Climate zones | As defined in clause 6.3.3 |
+| 2 | Informative classes | As defined in clause 6.3.4 |
+| 2 | CS/PS data ratio | Describes the fraction of circuit switched (CS) traffic vs. packet switched (PS) traffic in the network |
+
+## 6.3 Network classification
+
+To allow an extrapolation from the measured subnetworks ("partial" networks) to a complete network ("total" or "overall" networks), the test areas shall be classified into different categories as defined by network classification.
+
+The environmental classes used for network classification are: demography, topography and climate classes. These classes are described in the following clauses.
+
+### 6.3.1 Demography
+
+For the test purpose defined in this Recommendation, the MN shall be split into domains depending on population density. The following population density values per domain categories shall be used, as reported in Table 2.
+
+**Table 2 – Subnetwork demography classes**
+
+| Demography class | Typical population density [inhabitants/km 2 ] | Population range [inhabitants/km 2 ] |
+|---------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------|-------------------------------------------------|
+| Dense urban (DU) | 20 000 | > 10 000 |
+| Urban (U) | 2 000 | 1 000 – 10 000 |
+| Suburban (SU) | 300 | 200 – 1 000 |
+| Rural (RU) | 30 | 20 – 200 |
+| Unpopulated | 0 | < 20 |
+| Some references to databases where the demography distribution classes are reported can be found in [b-EU Eurostat], [b-UN Demography] and [b-USA Demography] | | |
+
+### 6.3.2 Topography
+
+The following topography classes shall be used, as reported in Table 3.
+
+**Table 3 – Subnetwork topography classes**
+
+| Proposed system | | Examples |
+|--------------------------|--------------|----------------------|
+| Topography class | Median slope | |
+| 1. Flat (FAO 1-3) | 0-5% | Denmark, Netherlands |
+| 2. Rolling (FAO 4-6) | >5-30% | France, Italy |
+| 3. Mountainous (FAO 7-8) | >30% | Norway, Switzerland |
+
+The above information is from the median slope gradient class world map ([b-FAO Topography]).
+
+### 6.3.3 Climate zones
+
+The following climate zones are identified as reported in Table 4.
+
+**Table 4 – Subnetwork climate classes**
+
+| Climate class | Sub-class | Explanation |
+|---------------|-----------|---------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| A: Tropical | | Temperature of the coldest month: $> 18^{\circ}\text{C}$ |
+| | Af | No dry season, at least 60 mm of rainfall in the driest month |
+| | Am | Monsoon type, short dry season but sufficient moisture to keep ground wet throughout the year |
+| | Aw | Distinct dry season, one month with precipitation $< 60$ mm |
+| B: Dry | | Arid regions where annual evaporation exceeds annual precipitation, marked dry season |
+| | BS | Steppe climate |
+| | BW | Desert |
+| C: Temperate | | Average temperature of the coldest month $< 18^{\circ}\text{C}$ and $> -3^{\circ}\text{C}$ , and average temperature of warmest month $> 10^{\circ}\text{C}$ |
+| | Cw | Winter dry season, at least ten times as much precipitation in wettest month of summer as in driest month of winter |
+| | Cs | Summer dry season, at least three times as much rain in wettest month of winter as in driest month of summer, the latter having less than 30 mm precipitation |
+| | Cf | At least 30 mm precipitation in the driest month, difference between wettest month and driest month less than for Cw and Cs |
+| D: Cold | | Average temperature of the warmest month $> 10^{\circ}\text{C}$ and that of coldest month $< -3^{\circ}\text{C}$ |
+| | Df | At least 30 mm of rain in the driest month, difference between wettest month and driest month less than for Cw and Cs |
+| | Dw | At least 10 times as much precipitation in wettest month of summer as in driest month of winter |
+| E: Polar | | Average temperature of the warmest month $< 10^{\circ}\text{C}$ |
+| | Et | Tundra, average temperature of warmest month $> 0^{\circ}\text{C}$ |
+| | Ef | No month with temperature $> 10^{\circ}\text{C}$ |
+
+The above reported climate classification is based on FAO Koeppen classification ([b-FAO Climate]). The indication based on the five main classes A to E is mandatory; the subclasses are optionally indicated.
+
+### 6.3.4 Informative classification classes
+
+In order to properly select the subnetwork operators penetration ratio and data traffic types could be reported for information. Table 5 reports the classification based on penetration classes, Table 6 reports the classification based on data volume (DV) classes.
+
+**Table 5 – Subnetwork penetration classes**
+
+| Symbol | Operator penetration class | Range |
+|--------|----------------------------|-------------------|
+| DP | Dominant penetration | > 30% penetration |
+| NDP | Non-dominant penetration | < 30% penetration |
+| MP | Minor penetration | < 10% penetration |
+
+**Table 6 – Subnetwork data volume classes**
+
+| Symbol | Traffic Class | Specific threshold |
+|--------|-------------------------------|----------------------------------------------------------|
+| CS | CS dominating | > 50% of data volume is CS |
+| PSS | PS – small packets dominating | > 50% of data volume is PS > 80% of packets are small |
+| PSL | PS – large packets dominating | > 50% of data volume is PS < 80% of packets are small |
+
+# 7 Metrics for energy efficiency assessment
+
+The following metrics shall be used to assess the mobile network energy efficiency.
+
+## 7.1 Energy consumption metrics
+
+The mobile network energy consumption ( $EC_{MN}$ ) is the sum of the energy consumption of equipment included in the MN under investigation (see clause 6). The network energy consumption is measured according to the assessment process defined in clause 8 such that individual metrics are provided per radio access technology (RAT) and per operator.
+
+$$EC_{MN} = \sum_i (\sum_k EC_{BS_{i,k}} + EC_{SI_i}) + \sum_j EC_{BH_j} + \sum_l EC_{RC_l} \quad (1)$$
+
+where:
+
+EC is energy consumption
+
+BS refers to the base stations in the MN under measurement
+
+BH is the backhaul providing connection to the BSs in the MN under measurement
+
+SI is the site infrastructure (rectifier, battery losses, climate equipment, tower mount amplifier (TMA), tower illumination, etc.)
+
+RC is the control node(s), including all infrastructure of the RC site
+
+$i$ is an index spanning over the number of sites
+
+$j$ an index spanning over the number of BH equipment connected to the $i$ sites
+
+$k$ is the index spanning over the number of BSs in the $i$ -th site
+
+$l$ is the index spanning over the control nodes of the MN
+
+$EC_{MN}$ shall be measured in Wh over the period of measurement $T$ (see clause 8).
+
+NOTE 1 – If the control node(s) supports a larger MN than that which is assessed, only a proportional share of RC EC is considered, proportional to the radio network controller (RNC) share of traffic that belongs to the MN being assessed.
+
+The energy sources available in the sites (power grid, genset, etc.) shall be reported in the tables of clause 10.
+
+NOTE 2 – power generation is not part of MN energy efficiency, but reported for information, for use in total cost of ownership (TCO) and greenhouse gas (GHG) analyses.
+
+## 7.2 Performance metrics
+
+The MN performance metrics are derived from parameters of the MN under investigation (see clause 6) relevant for energy efficiency, in particular the total data volume ( $DV_{MN}$ ) delivered by all its equipment and its global coverage area ( $CoA_{MN}$ ).
+
+For packet switched services, $DV_{MN}$ is defined as the data volume delivered by the equipment of the MN under investigation during the time frame $T$ of the energy consumption assessment. The assessment process defined in clause 8 shall be used.
+
+$$DV_{MN-PS} = \sum_{i,k} DV_{BS_{i,k}-PS} \quad (2)$$
+
+where $DV$ , measured in bits, is the performance delivered in terms of data volume in the network over the measurement period $T$ (see clause 8); $i$ and $k$ are defined in formula (1).
+
+For circuit switched services such as voice, $DV_{MN-CS}$ is defined as the data volume delivered by the equipment of the MN under investigation during the time frame $T$ of the energy consumption assessment.
+
+$$DV_{MN-CS} = \sum_{i,k} DV_{BS_{i,k}-CS} \quad (3)$$
+
+where $DV$ , measured in bits, is the performance delivered in terms of data volume in the network over the measurement period $T$ (see clause 8); $i$ and $k$ are defined in formula (1).
+
+Note that here "circuit switched" refers to all voice, interactive services, and video services managed by the MNOs, including CS voice, voice over LTE (VoLTE) and real-time video services delivered through dedicated bearers. The assessment process defined in clause 8 shall be used.
+
+The overall data volume is computed as follows:
+
+$$DV_{MN} = DV_{MN-PS} + DV_{MN-CS} \quad (4)$$
+
+$DV_{MN}$ can be derived from standard counters defined in [ETSI TS 132 425] and [ETSI TS 132 412] for LTE or equivalent used for 2G and 3G, multiplying by the measurement duration $T$ . The counters (in [ETSI TS 132 425] and [ETSI TS 132 412]) account also for quality of service (QoS) being reported in QoS class identifier (QCI) basis (see [ETSI TS 123 203]).
+
+NOTE – $DV_{MN}$ includes data volumes for downlink (DL) and uplink (UL)
+
+BH supervision and control data volumes are not considered (in order to include only the payload).
+
+$DV_{MN}$ is computed in bits.
+
+The $CoA_{MN}$ is also considered as a MN performance metric in the MN designed primarily for coverage goals (and hence especially in RU environments). The assessment process defined in clause 8 shall be used. $CoA$ is computed in $m^2$ .
+
+## 7.3 Mobile network energy efficiency metrics
+
+Mobile network data energy efficiency ( $EE_{MN,DV}$ ) is the ratio between the performance indicator ( $DV_{MN}$ ) and the energy consumption ( $EC_{MN}$ ) when assessed during the same time frame.
+
+$$EE_{MN,DV} = \frac{DV_{MN}}{EC_{MN}} \quad (5)$$
+
+where $EE_{MN,DV}$ is expressed in bit/J.
+
+The MN coverage energy efficiency ( $EE_{MN,CoA}$ ) is the ratio between the area covered by the MN under investigation (See clause 6) and the energy consumption when assessed during one year. $EE_{MN,CoA}$ is mainly used to complement $EE_{MN,DV}$ for MNs handling low data volumes, in particular in rural or deep rural areas. The area covered shall be assessed using rules (i.e., derived from geographic data or propagation models) defined in clause 8.
+
+$$EE_{MN,CoA} = \frac{\text{coverage area}}{EC_{MN}} \quad (6)$$
+
+where $EE_{MN,CoA}$ is expressed in $m^2/J$ and $EC_{MN}$ is the yearly energy consumption.
+
+# 8 Measurement of energy efficiency
+
+The measurement of the $EE_{MN}$ in the MN under investigation shall be based on the separate measurement of the performance (in terms of capacity and coverage) and energy, according to the metrics defined in clause 7.
+
+## 8.1 Time duration of the measurement
+
+The time duration of the measurement, denoted as $T$ , shall be one of the following alternatives:
+
+- weekly measurement: $T$ equal to 7 days;
+- monthly measurement: $T$ equal to 30 days;
+- yearly measurement: $T$ equal to 365 days.
+
+The minimum duration therefore, is one week; monthly and yearly measurements are extensions of the basic week test. For the CoA metric the energy consumption shall always be extrapolated to a one year time duration.
+
+## 8.2 Measurement procedures
+
+### 8.2.1 Measurement of energy consumption
+
+The energy consumption of the MN can be measured by means of metering information provided by utility suppliers or by mobile network integrated measurement systems ([b-ETSI ES 202 336-12]). Moreover, sensors can be used to measure site and equipment energy consumption.
+
+The $EC_{MN}$ is based on site granularity and includes all the equipment that is on the MNO sites (including the network controllers whenever applicable). The $EC_{MN}$ shall be differentiated per MNO providing service to the MN; in case of shared infrastructure the $EC_{MN}$ of the shared sites shall be computed per MNO, sharing those sites in a proportional ratio. In the case of separate metering per MNO, the respective part of the $EC_{MN}$ shall be assigned to each MNO.
+
+The $EC_{MN}$ shall be based on a per RAT estimation. If in the site there are BS of different RATs the $EC_{MN}$ shall be measured per RAT.
+
+The list of equipment operating in the MN sites under investigation shall be reported in the assessment report, including cooling, power conversion, etc. For a site with multi-RAT equipment the energy consumption of that equipment shall be split among each RAT proportionally to the configured RF power transmitted by each RAT; further details on the multi-RAT will be issued according to the development of multi-RAT measurements in [ITU-T L.1310].
+
+The reporting frequency of the $EC_{MN}$ should be aligned with the energy provider settings and mobile network performance assessment settings. It shall be reported in the assessment report.
+
+NOTE – As soon as a mobile network integrated measurement system will be available [b-ETSI ES 202 336-12], it should be used in addition to the utility provided $EC_{MN}$ , allowing a more precise estimation of the consumption per RAT and per MNO.
+
+### 8.2.2 Measurement of capacity
+
+The $DV_{MN}$ shall be measured using network counters for data volume related to the aggregated traffic in the set of BSs considered in the MN under test.
+
+For PS traffic, the data volume is considered as the overall amount of data transferred to and from the users present in the MN under test. Data volume shall be measured in an aggregated way per RAT present in the MN and shall be measured referring to counters derived from vendor operation and maintenance (O&M) systems.
+
+For CS traffic (e.g., CS voice or VoLTE), the data volume is considered as the number of minutes of communications during the observation period multiplied by the data rate of the corresponding service and the call success rate. The call success rate is equal to 1 minus the sum of blocking and dropping rates, i.e.,
+
+$$\text{Call Success Rate} = (1 - \text{blocking rate})(1 - \text{dropping rate}) \times 100 [\%] \quad (7)$$
+
+The blocking rates are computed using the O&M counters. They are composed of traffic channel (TCH) and signalling channel (SCH) blocking rates:
+
+$$1 - \text{blocking rate} = (1 - \text{TCH blocking rate})(1 - \text{SCH blocking rate}) \quad (8)$$
+
+The dropping includes the intracell call failure and the handover failure:
+
+$$1 - \text{dropping rate} = (1 - \text{intracell failure rate})(1 - \text{handover failure rate}) \quad (9)$$
+
+In order to include reliability in the measurement, the aggregated data volume shall be provided together with the 95th percentile of the cumulative distribution for each RAT in the MN.
+
+NOTE 1 – It is not possible for data services to determine a user related QoS, i.e., to identify for each data connection if a target throughput has been reached using counters. Such a computation would need the usage of probes that is out of scope of this Recommendation.
+
+NOTE 2 – As soon as the minimization of drive tests (MDT) related measurements in [ETSI TS 136 314] are available, the data volume may be measured according to the specification given therein (especially referring to clause 4.1.8 in [ETSI TS 136 314]). In this case, the per-user information about QoS can be obtained for data services and only connections with good QoS should be considered.
+
+### 8.2.3 Determination of coverage area
+
+Coverage area ( $CoA_{MN}$ ) is subject to network planning and intended services delivered within a certain geographic area. These parameters vary according to an MNO strategy and might, therefore, differ from MNO to MNO but also within the network of one MNO for a different geographical area.
+
+The coverage area shall be described by two distinct methods:
+
+- 1) calculated coverage area derived from network design, planned service and geographical data;
+- 2) measured network coverage based on user equipment (UE) reporting.
+
+#### 8.2.3.1 Geographic coverage area
+
+The geographic network coverage area is the total two-dimensional area intentionally covered by the selected subnetwork. This area is defined by an MNO defined network service plan (minimum granted data rate/typical data rate, etc.) for the selected test area. The area is based on base station power, propagation conditions in the selected area and accepted outage criteria.
+
+#### 8.2.3.2 Coverage ratio/effective coverage area
+
+The actual coverage area might differ from the originally planned coverage area (coverage holes within the considered area). The coverage ratio (CR) is a measure used to estimate the actual covered fraction of the planned total coverage area. User equipment reports such as signal strength and failed call attempts shall be used to more accurately determine the covered fraction. Drive tests and similar additional measurement campaigns should be avoided.
+
+The coverage ratio / effective coverage area (ECA) shall be provided for network efficiency result evaluations. It is linked to network quality and has to be defined in relation to the QoS definitions.
+
+A coverage map based on signal quality (signal to interference plus noise ratio (SINR)), such as the one shown in Figure 2, could be used to determine the fraction of the total area where a signal quality above a certain minimum value is achieved. However, such maps require a large number of measurements and drive tests.
+
+
+
+Figure 2: Typical SINR distribution of a mobile network. The figure shows a hexagonal map of a network area with a color-coded SINR distribution. The colors range from green (low SINR) to yellow, orange, and red (high SINR). A legend at the bottom indicates SINR Strength (dB) with categories: < -2 (green), -2 to 0 (yellow), 0 to 2 (orange), and > 2 (red).
+
+**Figure 2 – Typical SINR distribution of a mobile network**
+
+For the sake of energy efficiency metrics it is not required to have the knowledge of the actual coverage hole locations. From an energy efficiency point of view, it is important to know how many users/sessions or served users/sessions experienced problems because of the lack of coverage in relation to the total number of users/sessions or served users/sessions within the considered area.
+
+This allows a number of simplifications and an indirect determination of the coverage ratio.
+
+The CR for a base station is defined:
+
+Using the effective ECA and the designed coverage area (DCA) as:
+
+$$CR = ECA / DCA \quad (10)$$
+
+The effective coverage shall be measured based on coverage failures reported by the appropriate network counters:
+
+$$CR = 1 - \text{"percentage of users/sessions with coverage failure"} \quad (11)$$
+
+The following indicators shall be used to calculate the coverage failure:
+
+- RRC set-up failure ratio (Call set-up failure ratio);
+- RAB set-up failure ratio (UE-BS radio interface failure);
+- RAB release failure ratio (UE-BS radio interface failure).
+
+An additional factor, which can indicate a coverage issue, is the handover drop ratio. A handover drop can have multiple reasons (cell overload, UE speed, etc.). Furthermore, the handover drop rate depends on the network structure (number of neighbour cells). Its calculation requires several additional network parameters and complicates the data collection and analysis significantly. This factor is therefore omitted.
+
+The coverage ratio is defined as follows:
+
+$$CR = 1 - (1 - RRC \text{ set-up failure ratio}) * (1 - RAB \text{ set-up failure ratio}) * (1 - RAB \text{ release failure ratio})$$
+
+The needed parameters are specified by 3rd Generation Partnership Project (3GPP) standards and the results can be obtained from network management and supervision.
+
+The failure ratios are the fraction of failures of the total number of attempts:
+
+RRC set-up failure ratio = failed RRC connection establishments/attempted RRC connection establishments.
+
+RAB set-up failure ratio = RAB set-up failure/RAB set-up attempted.
+
+RAB release failure ratio = RAB release failure/RAB release attempted.
+
+**Table 7 – Measurement parameters required for coverage ratio calculation
+(refer to [ETSI TS 152 402], [ETSI TS 132 405] and [ETSI TS 132 425]
+for 2G, 3G and 4G definition/source reference respectively)**
+
+| Parameter | Function | Counter name |
+|-----------------------------------------|--------------------------------|--------------------------|
+| Failed RRC connection establishments | Radio resource control | RRC.ConnEstabFail.sum |
+| Attempted RRC connection establishments | Radio resource control | RRC.ConnEstabAtt.sum |
+| RAB set-up failure | Initial context set-up attempt | RAB.EstabInitFailNbr.sum |
+| RAB set-up attempted | Initial context set-up attempt | ERAB.EstabInitAttNbr.sum |
+| RAB release failure | RAB release | RAB.RelFailNbr.sum |
+| RAB release attempted | RAB release | ERAB.RelAttNbr.sum |
+
+The following averaging procedure is then used to obtain an average coverage ratio of the partial network under test:
+
+$$CR_{MN} = \sum_{i,k} CR_{BS_{i,k}} DCA_{BS_{i,k}} / \sum_{i,k} DCA_{BS_{i,k}} \quad (13)$$
+
+where:
+
+BS refers to the base stations in the MN under measurement
+
+*i* is an index spanning over the number of sites
+
+*k* is the index spanning over the number of BSs in the *i*-th site.
+
+# 9 Extrapolation for overall networks
+
+The EE measured according to clauses 7 and 8 can be used to extrapolate to larger networks. When such an extrapolation is made, it shall be performed following the method presented in this clause.
+
+The subnetwork data shall be extrapolated to overall/total networks according to demography, topography and climate classifications, as described in clause 6.
+
+The extrapolation shall be done according to statistical information that indicates how recurrent the subnetwork is within the total network to be addressed.
+
+Figure 3 reports the logic of the extrapolation from one subnetwork to a set of subnetworks ("total" network).
+
+
+
+The diagram illustrates the extrapolation process from a single subnetwork to a 'total' network. On the left, a single subnetwork is shown with a hierarchical structure: at the top is an 'RC' (Radio Controller) connected to three 'Backhaul equipment' units. These units are connected to three 'Site (wide area BS)' units. Each 'Site' contains a 'Base station' and 'Site equipment'. Below each 'Site' are two 'Local area BS' units. In the center, there are two 'Medium range BS' units. A large grey arrow points from this single subnetwork to the right. On the right, the 'total' network is shown as a stack of three identical subnetworks, indicating that the single subnetwork is being extrapolated to multiple subnetworks. The text 'L.1330(15)\_F03' is located at the bottom right of the diagram.
+
+Diagram illustrating the extrapolation from one subnetwork to a set of subnetworks ('total' network).
+
+**Figure 3 – Extrapolation from one subnetwork to a set of subnetworks ("total" network)**
+
+## 9.1 Extrapolation method
+
+In the case where the overall/total network to be addressed is not completely known in terms of demographical, topographical or climatological composition, or if the measurements of clauses 7 and 8 are executed only in some and not all the subnetworks constituting the total network, then the results shall be presented according to the tables in clause 10.
+
+In such a case, it shall be indicated for each subnetwork what its perceptual recurrence is with respect to the global one, in terms of demographical, topographical and climatological composition. Otherwise, if the exact composition of the total network is completely known, then the extrapolation shall be made to achieve the information valid for the entire total network.
+
+The extrapolation procedure shall be based on the demography information classes as reported in Table 2. It is also optional to make extrapolation based on topography classes (Table 3) or on climate classes (Table 4) or on a combination of demography, topography and climate zones.
+
+The extrapolation shall be based on a demography number of classes sufficient to represent at least the 75 per cent of the entire total network area demographical distribution.
+
+The following clauses show how to obtain data on the statistical distribution of demography, topography and climate zones classes in the networks under test at the total level. This information is to be used as a reference for every network area where the present specification will be used.
+
+### 9.1.1 Statistical information about demography
+
+An example of demographical information for Europe, e.g., for population or population density, can be found in [b-EU Eurostat], to classify the subnetwork under test under a demography class as in Table 2.
+
+An example referring to UN information is found in [b-UN Demography]. An example for USA information can be found in [b-USA Demography].
+
+### 9.1.2 Statistical information about topography
+
+An example of topography information can be found in [b-FAO Topography], to classify the subnetwork under test under a topography class as in Table 3.
+
+### 9.1.3 Statistical information about climate zones
+
+An example of climate information can be found in [b-FAO Climate], to classify the subnetwork under test under a climate class as in Table 4.
+
+## 9.2 Extrapolation reporting tables
+
+Table 8 indicates how to report the data for extrapolation towards total EE based on demography only. This is the mandatory approach when extrapolation data are computed. Not all of the classes shall be measured, but rather only those that allow coverage of at least 75 per cent of the entire demographical distribution of the total area under measurement.
+
+For all the subnetworks, the results of EE are reported according to clause 10 tables and the relative class shall be indicated. For all the same class measurement an average of EE measurements shall be reported in Table 8; this shall be done both for data volume EE and for coverage area EE, whichever metric is used.
+
+Then, for each class an average EE shall be computed as follows:
+
+$$EE_{class,av} = \frac{\sum_k EE_{MN,k}}{K} \quad (14)$$
+
+where "class" stands for one of the demography classes (DU, U, SU, RU or Unpopulated), $k$ is an index that runs over the number $K$ of subnetworks per class.
+
+The total EE shall be computed as a weighted sum of all the averages available, the weights are the percentage of each demography class versus the sum of the available classes' percentages. These percentages shall be derived from the information according to the examples of clause 9.1.
+
+The total EE shall be then computed as follows:
+
+$$EE_{total} = \frac{\sum_m PofP_m EE_{class,av,m}}{\sum_m PofP_m} \quad (15)$$
+
+where:
+
+$PofP_m$ is the percentage of presence of the $m$ -th demography class in the network under test
+
+$m$ is an index spanning over the number of classes
+
+$EE_{class,av,m}$ is the $m$ -th average as computed in equation (14).
+
+### 9.2.1 Reporting extrapolation based on demography
+
+In Table 8 the reporting extrapolation method based on demography is summarized.
+
+**Table 8 – Reporting extrapolation table based on demography**
+
+| Demography classification | Percentage of presence (PofP) in the total network area of the class | EE MN in the class | |
+|---------------------------|----------------------------------------------------------------------|-------------------------------|-------------------------------|
+| | | EE MN,DV | EE MN,CoA |
+| Dense urban (DU) | PofP DU [%] | EEDU,av | EEDU,av |
+| Urban (U) | PofP U [%] | EEU,av | EEU,av |
+| Suburban (SU) | PofP SU [%] | EESU,av | EESU,av |
+| Rural (RU) | PofP RU [%] | EERU,av | EERU,av |
+| Unpopulated | PofP Unp [%] | EEUnp,av | EEUnp,av |
+| Total EE | | EEtotal,DV | EEtotal,CoA |
+
+The demography table is the mandatory extrapolation representation. In case the topography and climate zone classifications are also available for the subnetworks measured according to clause 10. Table 9 and Table 10 also have to be reported.
+
+### 9.2.2 Reporting extrapolation based on topography
+
+In Table 9 the reporting extrapolation method based on topography is summarized.
+
+**Table 9 – Reporting extrapolation table based on topography**
+
+| Topography classification | Percentage of presence (PofP) in the total network area of the class | EE MN in the class | |
+|---------------------------|----------------------------------------------------------------------|-------------------------------|-------------------------------|
+| | | EE MN,DV | EE MN,CoA |
+| 1. Flat (FAO 1-3) | PofP Flat [%] | EEFlat,av | EEFlat,av |
+| 2. Rolling (FAO 4-6) | PofP Roll [%] | EERoll,av | EERoll,av |
+| 3. Mountainous (FAO 7-8) | PofP Mount [%] | EEMount,av | EEMount,av |
+| Total EE | | EEtotal,DV | EEtotal,CoA |
+
+### 9.2.3 Reporting extrapolation based on climate zones
+
+In Table 10 the reporting extrapolation method based on climate zones is summarized.
+
+**Table 10 – Reporting extrapolation table based on climate zones**
+
+| Climate zone classification | Percentage of presence (PofP) in the total network area of the class | EE MN in the class | |
+|-----------------------------|----------------------------------------------------------------------|-------------------------------|-------------------------------|
+| | | EE MN,DV | EE MN,CoA |
+| A: Tropical | PofP Trop % | EETrop,av | EETrop,av |
+| B: Dry | PofP Dry % | EEDry,av | EEDry,av |
+| C: Temperate | PofP Temp % | EETemp,av | EETemp,av |
+| D: Cold | PofP Cold % | EECold,av | EECold,av |
+| E: Polar | PofP Polar % | EEPolar,av | EEPolar,av |
+| Total EE | | EEtotal,DV | EEtotal,CoA |
+
+# 10 Assessment report
+
+The results of the assessments shall be reported accurately, clearly, unambiguously and objectively, and in accordance with any specific instructions in the required method(s).
+
+The report shall include tables defined in clauses 10.1 to 10.3. Items in italics can be considered optional.
+
+Further guidelines on the test report can be found in clause 5.10 of [ISO/IEC 17025].
+
+## 10.1 Report of network area under test
+
+Table 11 reports the details of the network area under test, representing a subnetwork where the measurements are conducted. The network area is the area encompassing all the sites under measurement; the CoA is computed starting from the area covered by each site and aggregating for all the sites in the network area under test.
+
+For each site reported in Table 11 the details shall be included in Table 12. Table 13 reports the measurements results for each site.
+
+**Table 11 – Report of network area under test**
+
+| Network area under test | |
+|-----------------------------------------------------------------------------|-------------------------------------------------------------|
+| Demography class [Dense urban, Urban, Suburban, Rural, Sparse] [Table 2] | |
+| Topography class [Table 3] | |
+| Climate zone [Table 4] | |
+| Informative classification [Table 5, Table 6] | |
+| Network area definition [by demography, by geography, by topology] | |
+| | Number of inhabitants in network the area [estimate] |
+| | Network area dimensions [estimate, km2 ] |
+
+**Table 11 – Report of network area under test**
+
+| | | |
+|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------|--|
+| Network area under test | | |
+| | Number of sites in the network Area [same radio controller?] | |
+| Type of sites in the network area | | |
+| | Number of wide area sites | |
+| | Number of medium range sites | |
+| | Number of other sites/equipment (local area, relay nodes, etc.) | |
+| Sites categorization | | |
+| | Number of sites in an MNO local exchange premise | |
+| | Number of sites in buildings not owned by MNO | |
+| | Number of sites in a shelter | |
+| | Number of any other sites | |
+| Multi-MNO sites | | |
+| | Number of "single MNO" sites | |
+| | Number of co-located multi- MNOs sites | |
+| | Number of sites in "Network Sharing" mode | |
+| Multi-technology sites | | |
+| | Number of 2G only sites | |
+| | Number of 3G only sites | |
+| | Number of LTE only sites | |
+| | Number of 2G+3G sites | |
+| | Other options [indicate] | |
+| Backhauling information | | |
+| | Predominant type of backhauling [wireless, fibre, copper...] | |
+| | Number of backhauling links per type | |
+| Energy efficiency in the network Area | | |
+| | EE MN,DV [b/J] | |
+| | EE MN,CoA [m 2 /J] | |
+| Energy efficiency top-down approach results | | |
+| NOTE – In case any alternative EE approach has been conducted on the network under test (i.e., measuring the aggregated energy consumption and the aggregated data volume or coverage area) the results of the evaluation shall be reported here for comparison purposes | | |
+
+## 10.2 Report of sites under test
+
+**Table 12 – Report of sites under test**
+
+| Site(s) under test in the network area (one table per site type to be measured in the network area) | | |
+|-------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------|--------------------|
+| Measurement duration | | |
+| | Time duration of the measurement [T] | |
+| | Measurement start date and time | |
+| | Measurement finish date and time | |
+| Type of site | | |
+| | Site "layer" [wide area, medium range, other] In case of wide area, indicate number of sectors and carriers per sector | |
+| | Site "technology" [2G, 3G, 2G+3G, LTE only, 2G+3G+LTE, other] | |
+| | Site "MNOs" [single MNO, co-location, network sharing, other] | |
+| Site and equipment age Initial commission date of the site Commission date of the current equipment in the site | | |
+| Temperature Average temperature [over period T] Minimum temperature Maximum temperature | Internal °C | External °C |
+| Site infrastructure | | |
+| | Site location [local exchange premise, building, shelter, other] | |
+| | Site composition | |
+| | Air conditioners | |
+| | Rectifiers/batteries | |
+| | Fixed network equipment consumption | |
+| | Other | |
+| | Estimated percentage of infrastructure consumption in the site (ECsi ) | |
+| Energy efficiency enhancement methods affecting the site equipment during the test | | |
+| Estimated percentage of presence of this site type in the network area | | |
+| Electricity sources used in the site | | |
+
+**Table 12 – Report of sites under test**
+
+| Site(s) under test in the network area (one table per site type to be measured in the network area) | | |
+|----------------------------------------------------------------------------------------------------------------|-------------------|--|
+| | Electricity [%] | |
+| | Genset [%] | |
+| | Solar [%] | |
+| | Renewables [%] | |
+| | Others (indicate) | |
+
+## 10.3 Report of site measurement
+
+**Table 13 – Report of site measurement**
+
+| Site measurement | | |
+|-------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|--|
+| Measurement duration | | |
+| | Time duration of the measurement [T] | |
+| | Measurement start date and time | |
+| | Measurement finish date and time | |
+| Temperature class and average temperature during the test | | |
+| Energy consumption in the site | | |
+| | Method of measurement [energy bills/counters, sensors, equipment information, other] | |
+| | Measured energy consumption EC MN [Wh or multiples] | |
+| | Week energy consumption [per week data/graph] | |
+| | Month energy consumption [if T allows] | |
+| | Year energy consumption [if T allows] | |
+| Traffic offered in the site | | |
+| | Method of measurement [operational counters, backhauling data, MDT, other] | |
+| | Measured traffic volume DV [bit or multiples] | |
+| | Week traffic [per week data/graph] | |
+| | Month traffic [if T allows] | |
+| | Year traffic [if T allows] | |
+| Coverage of the site [data to be reported per RAT present in the site] | | |
+| | Designed coverage area CoA [km 2 ] | |
+| | Coverage ratio [%] | |
+| | Effective CoA [km 2 ] | |
+| | Failed RRC connection establishments Attempted RRC connection establishments RAB set-up failure RAB set-up attempted RAB release failure | |
+
+**Table 13 – Report of site measurement**
+
+| Site measurement | | |
+|--------------------------------|--------------------------------------------------------------|--|
+| | RAB release attempted | |
+| Site network energy efficiency | | |
+| | Measured energy efficiency $EE_{MN}$ [bit/J] and [ $m^2/J$ ] | |
+| | Weekly energy efficiency [per week data/graph] | |
+| | Monthly energy efficiency [if T allows] | |
+| | Yearly energy efficiency [if T allows] | |
+
+# 11 Implementation guidelines
+
+The specification is based on the mobile network area definition under test as described in clause 6, where measurements must be done according to the metrics defined in clause 7 and following the procedures defined in clause 8. In this way, the network under test is evaluated in terms of energy efficiency and the results obtained therein are to be filled in the tables reported as an essential part of the specification in clause 10.
+
+Extrapolation of subnetwork results can be used for the assessment of larger networks, in particular when measurement over the entire total network is not possible due to its dimensions. In this case, the extrapolation approach defined in clause 9 shall be used.
+
+Attention must be paid to the selection of the subnetworks where the measurements are made in order to ensure that the results are technically sound and, even if this is not the primary goal, comparable. Results measured in very different environments (different in terms of demography or climatology or topography, but also different due to the goal and function of the network) are hardly comparable and the purpose of this specification is not to make comparable what is not. However, the important issue is to introduce a method of testing that can represent a common reference whenever a test of mobile network energy efficiency is performed over a radio access network.
+
+An essential part of this common base method is represented by the tables in clause 10. Even in very different scenarios, these tables are to be filled in completely in order for the measurements to be accepted and to be standards-based. In such a way, even if the measurements are done in very different scenarios, the details of the scenarios are reported in the tables and, not only considering the final EE results but also how they were obtained, the tests will be considered standards compliant.
+
+# Appendix I
+
+## Implementation examples
+
+(This appendix does not form an integral part of this Recommendation.)
+
+## Implementation examples
+
+Considering the implementation guidelines reported in clause 11, a set of examples showing how to implement the energy savings (ES) is given in this appendix.
+
+As an example, a possible application of this Recommendation is to provide national authorities a commonly accepted procedure to estimate, at national, regional or city level, the efficiency of a RAT or a set of RATs deployed by an MNO or a set of MNOs. This assessment can be stand-alone, in order to know what a reasonably achievable efficiency is, or it can be estimated towards a given threshold, to ensure that better efficiency is achieved (e.g., after the introduction of new ES procedures, or new hardware solutions).
+
+As another example, this Recommendation could be used to test the efficiency of a network year over year or in any given timeframe. The test can be performed over the same sub or total network, depending on the requirements, and over the network of the same MNO, in a different time period, i.e., year over year or in any case so as to emphasize a time evolution of the EE performances. Even in this case, the full completion of the information in the clause 10 tables is mandatory in order to check under which conditions the tests have been performed.
+
+As a final example, this Recommendation could also be used without any extrapolation phase (as described in clause 9) when the purpose of its use is to evaluate network functionalities that impact energy efficiency in a small network under test. In such a case, this Recommendation indicates the way to proceed to compare such small networks where the mentioned functionalities are activated with respect to the baseline case where the functionalities are not activated.
+
+## Examples of reporting data
+
+In this clause an example of data to be entered into the tables of clause 10 and clause 9 is given. This example is for explanation purposes only and the data reported therein are not to be considered real or binding in any possible way.
+
+Table I.1 is filled with example data.
+
+**Table I.1 – Example of reporting data**
+
+| Network area under test (Partial network #1) | | |
+|-----------------------------------------------------------------------------|---------------------------------------------------------------------------|--------------------|
+| Demography class [Dense urban, Urban, Suburban, Rural, Sparse] [Table 2] | Dense urban | |
+| Topography class [Table 3] | Flat | |
+| Climate zone [Table 4] | Temperate | |
+| Informative classification [Table 5, Table 6] | DP, PSL | |
+| Network area definition [by demography, by geography, by topology] | | |
+| | DemographyNumber of inhabitants in the Network area [estimate] | 150 000 |
+| | Network area dimensions [estimate, km 2 ] | 15 km 2 |
+
+**Table I.1 – Example of reporting data**
+
+| Network area under test (Partial network #1) | | |
+|-----------------------------------------------------|-----------------------------------------------------------------|----------------------|
+| | Number of sites in the network area [same radio controller?] | 30, of the same RC |
+| Type of sites in the network area | | |
+| | Number of wide area sites | 25 |
+| | Number of medium range sites | 3 |
+| | Number of other sites/equipment (local area, relay nodes, etc.) | 2 |
+| Sites categorization | | |
+| | Number of sites in an MNO local exchange premise | 5 |
+| | Number of sites in buildings not owned by MNO | 20 |
+| | Number of sites in a shelter | |
+| | Number of any other sites | 5 |
+| Multi-MNO sites | | |
+| | Number of "single MNO" sites | 20 |
+| | Number of co-located multi-MNOs sites | 8 |
+| | Number of sites in "Network Sharing" mode | 2 |
+| Multi-technology sites | | |
+| | Number of 2G only sites | 0 |
+| | Number of 3G only sites | 10 |
+| | Number of LTE only sites | 5 |
+| | Number of 2G+3G sites | 10 |
+| | Other options [indicate] | 5 2G+3G+LTE |
+| Backhauling information | | |
+| | Predominant type of backhauling [wireless, fibre, copper...] | Fibre, copper |
+| | Number of backhauling links per type | 20 fibre, 10 copper |
+| Energy efficiency in the network area | | |
+| | EE MN,DV [b/J] | 180 b/J |
+| | EE MN,CoA [m 2 /J] | 3 m 2 /MJ |
+| Energy efficiency top-down approach results | | |
+| | 100 bit/J | |
+
+Table I.2 reports an example of a site in the partial network #1 described above.
+
+**Table I.2 – Example of a site in the partial network #1**
+
+| Site(s) under test in the network area (one table per site type to be measured in the network area) | | |
+|-------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------|
+| Measurement duration | | |
+| | Time duration of the measurement [T] | 2 weeks |
+| | Measurement start date and time | 2014/07/07 |
+| | Measurement finish date and time | 2014/07/20 |
+| Type of site | | |
+| | Site "layer" [wide area, medium range, other] In case of wide area, indicate number of sectors and carriers per sector | Wide area, 3 sectors 2 carriers each sector |
+| | Site "technology" [2G, 3G, 2G+3G, LTE only, 2G+3G+LTE, other] | 3G |
+| | Site "MNOs" [single MNO, co-location, network sharing, other] | Single MNO |
+| Site and equipment age Initial commission date of the site Commission date of the current equipment in the site | | 2005/11/05 initial 2013/07/22 current equipment |
+| Temperature Average temperature [over period T] Minimum temperature Maximum temperature | Internal °C 24.2 °C 18.8 °C 30.6 °C | External °C 28.3 °C 19.6 °C 36.4 °C |
+| Site infrastructure | | |
+| | Site location [local exchange premise, building, shelter, other] | Outdoor cabinet |
+| | Site composition | |
+| | Air conditioners | Yes, 2 kW average power |
+| | Rectifiers/ batteries | Yes, both; 250 W average power |
+| | Fixed network equipment consumption | |
+| | Other | |
+| | Estimated percentage of infrastructure consumption in the site (ECsi ) | 50% |
+
+**Table I.2 – Example of a site in the partial network #1**
+
+| Site(s) under test in the network area (one table per site type to be measured in the network area) | | |
+|----------------------------------------------------------------------------------------------------------------|-------------------------------------------------|-----|
+| Energy efficiency enhancement methods affecting the site equipment during the test | Traffic related power off of the second carrier | |
+| Estimated percentage of presence of this site type in the network area | 33% | |
+| Electricity sources used in the site | | |
+| | Mains/power grid [%] | 80% |
+| | Genset [%] | – |
+| | Solar [%] | 20% |
+| | Other renewables [%] | – |
+| | Others (indicate) | – |
+
+Table I.3 reports the measurement in the site described in the table above.
+
+**Table I.3 – Example of measurement in a site**
+
+| Site measurement | | |
+|-----------------------------------------------------------|--------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------|
+| Measurement duration | | |
+| | Time duration of the measurement [T] | 2 weeks |
+| | Measurement start date and time | 2014/07/07 |
+| | Measurement finish date and time | 2014/07/20 |
+| Temperature class and average temperature during the test | | |
+| Class C, average internal temperature 24.2 °C | | |
+| Energy consumption in the site | | |
+| | Method of measurement [energy bills/counters, sensors, equipment information, other] | Sensors |
+| | Measured energy consumption $EC_{MN}$ [Wh or multiples] | |
+| | Week energy consumption [per week data/graph] | Introduce a graph of the kWh in the site, or a table of values, per week, according to the time granularity of the available data |
+| | Month energy consumption [if T allows] | N/A |
+| | Year energy consumption [if T allows] | N/A |
+| Traffic offered in the site | | |
+| | Method of measurement [operational counters, backhauling data, MDT, other] | Operational counters |
+| | Measured traffic volume $DV$ [bit or multiples] | |
+| | Week traffic [per week data/graph] | Introduce a graph of the Gb in the site, or a table of values, per |
+
+**Table I.3 – Example of measurement in a site**
+
+| Site measurement | | |
+|------------------------------------------------------------------------|------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------|
+| | | week, according to the time granularity of the available data |
+| | Month traffic [if T allows] | NA |
+| | Year traffic [if T allows] | NA |
+| Coverage of the site [data to be reported per RAT present in the site] | | |
+| | Designed coverage area CoA[km 2 ] | 0.5 |
+| | Effective coverage area CoA [km 2 ] | 0.42 |
+| | Coverage ratio [%] | 84% |
+| | Failed RRC connection establishments | 658 |
+| | Attempted RRC connection establishments | 13 118 |
+| | RAB set-up failure | 322 |
+| | RAB set-up attempted | 4 998 |
+| | RAB release failure | 294 |
+| | RAB release attempted | 4 998 |
+| Mobile network energy efficiency | | |
+| | Measured energy efficiency [bit/J] | |
+| | Weekly energy efficiency [per week data/graph] | Introduce a graph of the bit/J in the site, or a table of values, per week, according to the time granularity of the available data |
+| | Monthly energy efficiency [if T allows] | N/A |
+| | Yearly energy efficiency [if T allows] | N/A |
+
+Table I.4 reports an example of computation results of a total mobile network energy efficiency assessment. The EE values are in the format of tables for partial network 1, and other values are considered in other partial networks in the same partial network area (not reported in this example) to come to the average values in the EE columns. The total EE is evaluated in the measurement period T timeframe (2 weeks) for the DV case, while EC is extrapolated to one year as required for CoA EE metric.
+
+**Table I.4 – Example of computation of a global energy efficiency metric**
+
+| Demography classification | Percentage of presence (PofP) in the total network area of the class | EE MN in the class | |
+|---------------------------|----------------------------------------------------------------------|-------------------------------|------------------------------|
+| | | EE MN,DV | EE MN,CoA |
+| Dense urban (DU) | 42% | 200 b/J | 2.7 m 2 /MJ |
+| Urban (U) | 20% | 40 b/J | 19 m 2 /MJ |
+| Suburban (SU) | 15% | 8 b/J | 38 m 2 /MJ |
+| Rural (RU) | 13% | 2 b/J | 115 m 2 /MJ |
+| Unpopulated | 10% | N/A | N/A |
+| Overall/total EE | | 103.8 b/J | 28.4 m2 /MJ |
+
+In order to better clarify the example in the table above the following equations explain how to compute the total EE in the cases mentioned above.
+
+$$\begin{aligned}
+EE_{total,DV} &= \frac{PofP_{DU} * EE_{DU,av} + PofP_U * EE_{U,av} + PofP_{SU} * EE_{SU,av} + PofP_{Unp} * EE_{Unp,av}}{PofP_{DU} + PofP_U + PofP_{SU} + PofP_{Unp}} \\
+&= \frac{42 * 200 + 20 * 40 + 15 * 8 + 13 * 2}{42 + 20 + 15 + 13} = 103,8 \text{ b/J}
+\end{aligned}$$
+
+$$\begin{aligned}
+EE_{total,CoA} &= \frac{PofP_{DU} * EE_{DU,av} + PofP_U * EE_{U,av} + PofP_{SU} * EE_{SU,av} + PofP_{Unp} * EE_{Unp,av}}{PofP_{DU} + PofP_U + PofP_{SU} + PofP_{Unp}} \\
+&= \frac{42 * 2,7 + 20 * 19 + 15 * 38 + 13 * 115}{42 + 20 + 15 + 13} = 28,4 \text{ m}^2/\text{MJ}
+\end{aligned}$$
+
+Note that in the CoA case the extrapolation has been made from T=14 days to 1 year dividing by 26 the results during period T (365/14~26).
+
+# Bibliography
+
+- [b-ETSI ES 202 336-12] ETSI ES 202 336-12 V1.0.0 (2015), *Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (power, cooling and building environment systems used in telecommunication networks); Part 12: telecom/ICT equipment control and monitoring information model.*
+- [b-ETSI ES 202 706] ETSI ES 202 706 V1.4.1 (2014), *Environmental Engineering (EE); Measurement method for power consumption and energy efficiency of wireless access network equipment.*
+- [b-ETSI TR 103117] ETSI TR 103117 V1.1.1 (2012), *Environmental Engineering (EE); Principles for Mobile Network level energy efficiency.*
+- [b-EU Eurostat] European Union Population statistics.
+<>
+- [b-FAO Climate] FAO Reference on Climate Zones
+<[http://www.fao.org/fileadmin/user\\_upload/gaez/docs/GAEZ\\_Model\\_Documentation.pdf](http://www.fao.org/fileadmin/user_upload/gaez/docs/GAEZ_Model_Documentation.pdf)>
+- [b-FAO Topography] FAO Reference on Topography.
+< >
+- [b-UN Demography] UN Reference to demographical distribution.
+<>
+- [b-USA Demography] USA Reference to demographical distribution.
+<[http://factfinder2.census.gov/faces/tableservices/issf/pages/productview.xhtml?pid=DEC\\_10\\_V\\_ISF\\_P40&prodType=table](http://factfinder2.census.gov/faces/tableservices/issf/pages/productview.xhtml?pid=DEC_10_V_ISF_P40&prodType=table)>
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1332-201801-I_PDF-E/raw.md b/marked/L/T-REC-L.1332-201801-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..d956ee06b45166501b8b9ba1f49c1629552ebf5b
--- /dev/null
+++ b/marked/L/T-REC-L.1332-201801-I_PDF-E/raw.md
@@ -0,0 +1,568 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1332**
+
+(01/2018)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+# --- **Total network infrastructure energy efficiency metrics**
+
+Recommendation ITU-T L.1332
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+# **ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+| | |
+|--------------------------------------------------------|-------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.1332
+
+# Total network infrastructure energy efficiency metrics
+
+## Summary
+
+Recommendation ITU-T L.1332 contains the basic definition of energy efficiency metrics and measurement methods required to evaluate the energy efficiency of a total network, including the energy consumption for:
+
+- all telecommunication (TLC)/information and communications technology (ICT) equipment in the network;
+- all facilities equipment (e.g., cooling systems, site monitoring systems, fire protection and lighting systems);
+- energy losses in DC power station or AC UPS and in the power distribution;
+- maintenance activities and site-visit energy used for transportation (e.g., by car);
+- diesel generators used for emergency purposes.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1332 | 2018-01-13 | 5 | 11.1002/1000/13459 |
+
+## Keywords
+
+Energy efficiency, facilities, methodology, metrics.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2018
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|----------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Energy flow in telecommunication networks ..... | 2 |
+| 7 Maintenance activities ..... | 5 |
+| 7.1 Maintenance activities contribution to total energy budget ..... | 5 |
+| 8 Metric for total network..... | 6 |
+| 8.1 Total network infrastructure energy efficiency definition..... | 6 |
+| 9 Measurement methodology ..... | 6 |
+| 9.1 Test instrument requirements ..... | 7 |
+| 9.2 Observation period ..... | 7 |
+| 9.3 Load energy consumption ..... | 8 |
+| 9.4 Total network energy consumption ..... | 8 |
+| 10 Global indicator relationship ..... | 9 |
+| Bibliography..... | 10 |
+
+# Introduction
+
+The facilities or infrastructure parts of an information and communication technology (ICT) network are composed, at a minimum, of the following:
+
+- alternating current (AC) infrastructure;
+- AC/direct current (DC) or uninterruptable power source (UPS) conversion with batteries;
+- backup systems (e.g., diesel generators);
+- cooling systems.
+
+Without optimization, it is commonly considered that 50 per cent of the energy used in a telecommunication (TLC) installation is used or wasted by the infrastructure.
+
+Figure 0-1 shows an example of the energy loss distribution in a generic TLC site from high-voltage (HV) to ultra-low-voltage equipment used inside an ICT site.
+
+
+
+The diagram illustrates the energy loss distribution in an ICT site. The energy input is 10000 W at 10 kV. It passes through a transformer (AC2, 230/240 V) where it becomes 9500 W. Then, it goes through an AC distribution (AC3) where it becomes 9000 W. The energy is then split into two paths: one for the air conditioner (3500 W) and one for the UPS (2400 W). The UPS output goes to an AC distribution (AC4) where it becomes 2100 W. This is then converted to DC (DC1, LV 1800 W) and distributed (DC2, 1700 W). The energy is then converted to DC (DC3, 5/12 V) and distributed (DC4, 0.9~3.3 V). The final energy used by the network equipment is 1600 W, which is 37.5% of the input energy. The effective network energy is less than 50% of the input energy.
+
+| Stage | Power (W) | Voltage | Equipment |
+|------------------|-----------|------------|-----------------|
+| Energy input | 10000 | 10 kV | HV distribution |
+| Transformer | 9500 | 230/240 V | Transformer |
+| AC distribution | 9000 | 230/400 V | LV distribution |
+| AC3 | 3500 | 230/400 V | Air conditioner |
+| UPS | 2400 | 230/400 V | UPS |
+| AC4 | 2100 | 220/380 V | Converting |
+| DC1 | 1800 | 24/48/60 V | DC1 |
+| DC2 | 1700 | 24/48/60 V | DC2 |
+| DC3 | 1600 | 5/12 V | DC3 |
+| DC4 | 1400 | 0.9~3.3 V | DC4 |
+| Effective energy | 1600 | 0.9~3.3 V | Chip |
+
+Figure 0-1: Distribution of energy loss in an ICT site from HV electric input to final use in ICT chips at ultra-low voltage. The diagram shows energy flow from 10 kV input through various conversion and distribution stages, with significant losses at each step. The final effective energy for the network equipment is less than 50% of the input, with only 37.5% reaching the chips.
+
+**Figure 0-1 – Distribution of energy loss in an ICT site from HV electric input to final use in ICT chips at ultra-low voltage**
+
+To reduce the energy consumption and environmental impact of a TLC network it is useful to standardize a simple evaluation of the effect of power-reduction actions on the total energy consumption and wasted energy of the system.
+
+An indicator that considers the distribution of energy consumption from site input to final load in a network is useful. The power usage effectiveness (PUE) indicator is commonly used in data centres. PUE is the following ratio:
+
+$$PUE = \frac{\text{Total power consumption at site input}}{\text{Load power consumption at load power interface}}$$
+
+This type of indicator does not give sufficient information to evaluate the environmental impacts of infrastructure and losses inside the equipment itself, nor for energy used for external operations and maintenance activities.
+
+It is important to consider the total energy used by a network as this impacts the environmental and economic sustainability of the network.
+
+For example, the use of renewable energy shall be taken into account when considering the total environmental impact. It is necessary to consider different infrastructure solutions, possibly with different classes of energy sources on the total energy, and not only focus on electricity consumption and losses in the network.
+
+The total energy use includes energy consumption of:
+
+- loads;
+- power system losses (power station, UPS, feeder, transformer) including energy consumption of power cooling systems;
+- power and environment monitoring systems;
+- site and core-room fire protection systems;
+- lighting of site and core-rooms;
+- electric distribution losses;
+- site-visit fuel consumed by vehicles;
+- generators (diesel).
+
+Some standards developing organizations (SDOs) are defining key performance indicators (KPI) for energy management of operational infrastructure; these indicators are more related to how energy is managed in a network or in its elements.
+
+
+
+## Recommendation ITU-T L.1332
+
+# Total network infrastructure energy efficiency metrics
+
+# 1 Scope
+
+This Recommendation specifies principles and concepts of energy efficiency metrics and measurement methods to evaluate the energy efficiency of an entire network consisting of telecommunication equipment and infrastructure equipment.
+
+This Recommendation also develops the methodology to consider the influence on total energy consumption including maintenance activities; by establishing methodologies which consider the energy necessary for the transport activities embedded in the maintenance phase.
+
+Energy sources of different natures are taken into account in this Recommendation.
+
+For concepts of energy efficiency, see [ITU-T L.1315].
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T L.1315] Recommendation ITU-T L.1315 (2017), *Standardization terms and trends in energy efficiency*.
+- [ITU-T L.1330] Recommendation ITU-T L.1330 (2015), *Energy efficiency measurement and metrics for telecommunication networks*.
+- [ITU-T L.1350] Recommendation ITU-T L.1350 (2016), *Energy efficiency metrics of a base station site*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 AC ICT load:** Information and communication technology (ICT) equipment powered in alternating current (e.g., servers, routers).
+
+**3.2.2 DC ICT load:** Information and communication technology (ICT) equipment powered in direct current (e.g., transmission equipment, access equipment).
+
+**3.2.3 high-voltage (HV) connection:** High voltage is related to a powering solution in which the rms voltage is higher than 35 kV and lower than 230 kV.
+
+NOTE – This definition is in line with the voltage range established by [b-IEC 60038].
+
+**3.2.4 load energy consumption:** Energy consumption of ICT equipment present in the network under consideration.
+
+**3.2.5 low-voltage (LV) connection:** Low voltage is related to a powering solution in which the rms voltage is higher than 100 V and lower than 1000 V.
+
+NOTE – This definition is in line with the voltage range established by [b-IEC 60038].
+
+**3.2.6 medium-voltage (MV) connection:** Medium voltage is related to a powering solution in which the rms voltage is higher than 1 kV and lower than 35 kV.
+
+NOTE – This definition is in line with the voltage range established by [b-IEC 60038].
+
+**3.2.7 total network:** ICT network managed by an operator, consisting of: radio access network, fixed access network, core network and data centres that belong to the same operator.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|---------|-------------------------------------------|
+| AC | Alternating Current |
+| DC | Direct Current |
+| EloadAC | Energy consumption of AC load |
+| EloadDC | Energy consumption of DC load |
+| HV | High Voltage |
+| ICT | Information and Communications Technology |
+| KPI | Key Performance Indicator |
+| LV | Low Voltage |
+| MV | Medium Voltage |
+| NIEE | Network Infrastructure Energy Efficiency |
+| PUE | Power Usage Effectiveness |
+| RFT-C | Remote Feeding Telecommunication Current |
+| RFT-V | Remote Feeding Telecommunication Voltage |
+| RMS | Root-Mean-Square |
+| SDO | Standards Development Organization |
+| TLC | Telecommunication |
+| UPS | Uninterruptable Power Source |
+
+# 5 Conventions
+
+None.
+
+# 6 Energy flow in telecommunication networks
+
+Figures 1, 2 and 3 show examples of energy flows from the grid to large, medium and small telecommunication (TLC) installations, respectively.
+
+These examples show only cases where there is no locally generated electrical energy from renewable sources or from engine generators.
+
+Depending on the energy consumption of the site, it is possible to classify sites depending on their grid connection:
+
+- high-voltage (HV) connection;
+
+- medium-voltage (MV) connection;
+- low-voltage (LV) connection.
+
+On very large sites e.g., national data centres, the HV connection is adapted to the high-energy consumption of the site.
+
+In this case, located on the information and communications technology (ICT) site there will be a conversion from HV to MV and then a conversion from MV to LV.
+
+The AC LV is used to power the following equipment:
+
+- uninterruptable power source (UPS) for the ICT load/services that need permanent AC;
+- AC load, such as air conditioners, that do not need permanent AC;
+- DC (direct current) power stations for the ICT load/services.
+
+
+
+This diagram illustrates the energy flow for a large ICT installation. On the left, an HV/MV transformer connects the high-voltage grid to a medium-voltage bus. This is followed by an MV/LV transformer that connects to a low-voltage bus. From this bus, three main power paths emerge: 'AC no backup', 'UPS', and 'DC power feeding'. The 'AC no backup' path connects to a bus with three 'AC ICT load' units. The 'UPS' path connects to the same bus. The 'DC power feeding' path connects to a separate bus with three 'DC ICT load' units. The label 'L.1332(18)\_F01' is at the bottom right.
+
+Energy flow diagram for a large ICT installation showing HV to MV to LV conversion, with AC and DC power distribution to various loads.
+
+**Figure 1 – Energy flow from grid to ICT equipment: large ICT installation**
+
+
+
+This diagram illustrates the energy flow for a medium ICT installation. On the left, an MV/LV transformer connects the medium-voltage grid to a low-voltage bus. From this bus, three main power paths emerge: 'AC no backup', 'UPS', and 'DC power feeding'. The 'AC no backup' path connects to a bus with three 'AC ICT load' units. The 'UPS' path connects to the same bus. The 'DC power feeding' path connects to a separate bus with three 'DC ICT load' units. The label 'L.1332(18)\_F02' is at the bottom right.
+
+Energy flow diagram for a medium ICT installation showing MV to LV conversion, with AC and DC power distribution to various loads.
+
+**Figure 2 – Energy flow from grid to ICT equipment: medium ICT installation**
+
+
+
+This diagram illustrates the energy flow from a grid to various ICT equipment in a small installation. On the left, a vertical bus labeled 'Grid' connects to three main components: 'AC no backup', 'UPS', and 'DC power feeding'. The 'AC no backup' component is connected to a bus that feeds three 'AC ICT load' units. The 'UPS' component is also connected to this same bus, feeding the same three 'AC ICT load' units. The 'DC power feeding' component is connected to a separate bus that feeds three 'DC ICT load' units. The diagram is labeled 'L.1332(18)\_F03' at the bottom right.
+
+Energy flow from grid to ICT equipment: small ICT installation diagram
+
+**Figure 3 – Energy flow from grid to ICT equipment: small ICT installation**
+
+Small ICT sites, use energy flows that do not come only from the grid, but come from renewable energy sources as well.
+
+Two architectures are possible.
+
+Figure 4 shows the case in which renewable energy sources are connected to AC LV power distribution.
+
+Figure 5 shows the case in which renewable energy sources are connected to DC power distribution.
+
+
+
+This diagram shows renewable energy sources connected to an AC LV power distribution system. On the left, a green box labeled 'Renewable source' is connected to a vertical bus labeled 'LV'. This bus connects to three main components: 'AC no backup', 'UPS', and 'DC power feeding'. The 'AC no backup' and 'UPS' components are connected to a bus that feeds three 'AC ICT load' units. The 'DC power feeding' component is connected to a separate bus that feeds three 'DC ICT load' units. The diagram is labeled 'L.1332(18)\_F04' at the bottom right.
+
+Renewable energy sources connected to the AC LV power distribution diagram
+
+**Figure 4 – Renewable energy sources connected to the AC LV power distribution**
+
+
+
+```
+
+graph LR
+ LV --- AC_no_backup[AC no backup]
+ LV --- UPS[UPS]
+ LV --- DC_power_feeding[DC power feeding]
+ LV --- Renewable_source[Renewable source]
+ AC_no_backup --- GRID
+ UPS --- GRID
+ GRID --- AC_ict_load1[AC ICT load]
+ GRID --- AC_ict_load2[AC ICT load]
+ GRID --- AC_ict_load3[AC ICT load]
+ DC_power_feeding --- DC_bus
+ Renewable_source --- DC_bus
+ DC_bus --- DC_ict_load1[DC ICT load]
+ DC_bus --- DC_ict_load2[DC ICT load]
+ DC_bus --- DC_ict_load3[DC ICT load]
+
+```
+
+Diagram showing power distribution from a Low Voltage (LV) source. The LV source branches into four main paths: 'AC no backup', 'UPS', 'DC power feeding', and 'Renewable source'. The 'AC no backup' path connects to a 'GRID' bus, which then branches into three 'AC ICT load' units. The 'UPS' path also connects to the 'GRID' bus. The 'DC power feeding' path connects to a DC bus, which branches into three 'DC ICT load' units. The 'Renewable source' path also connects to the DC bus. A label 'L.1332(18)\_F05' is at the bottom right.
+
+**Figure 5 – Renewable energy sources connected to the DC power distribution**
+
+When an ICT installation is not connected to the grid, the site could be connected to a renewable energy source and/or to an engine generator in the case of a hybrid solution.
+
+# 7 Maintenance activities
+
+Maintenance activities in a network or in an ICT installation are normally not considered; however, maintenance routines can have a substantial impact on the energy used in network operations, this is especially true in the case of wide-area networks (e.g., mobile radio networks).
+
+The contribution of the maintenance energy consumption to the total energy budget should be assessed, but the method is not fully developed, at this stage, to provide more than a rough estimation. Further study is needed to provide more accurate maintenance activities characterized by:
+
+- periodicity;
+- distance.
+
+The periodicity is the frequency of interventions at the same site: it depends on the equipment or solution installed at a site and also on the site location, e.g., free cooling equipment needs a maintenance routine to clean or replace air filters; this maintenance periodicity is influenced by pollution conditions at the site.
+
+Distance is the distance between TLC/ICT sites and the maintenance centre. The distance shall be calculated in km.
+
+## 7.1 Maintenance activities contribution to total energy budget
+
+Maintenance activities consist of three phases:
+
+- 1) travel to site;
+- 2) performance of the maintenance;
+- 3) travel back to maintenance centre.
+
+This Recommendation suggests considering the energy contributions of phases 1 and 3 only, because the energy used during phase 2 is negligible in respect of the energy consumption of the travelling phases.
+
+The travelling distance shall be collected from records of all travelling maintenance activities. If this is not possible; the distance can be calculated as an average distance between maintenance centres and TLC/ICT sites multiplied by the number of sites.
+
+Using a conversion factor depending on the type of vehicle used, the distance can be converted into energy. This conversion factor depends on the car type/brand and it is suggested that an average value is used for the maintenance vehicle fleet.
+
+# 8 Metric for total network
+
+To define efficiency, networks use several types of indicators.
+
+The simplest indicator that can be used is one that considers only the utilization of energy inside the network. One such indicator is used to check the efficiency of facilities in a data centre.
+
+A proposed indicator for network efficiency is the ratio between the energy used by the load and the total energy consumed in the network.
+
+## 8.1 Total network infrastructure energy efficiency definition
+
+The metric for the total network infrastructure energy efficiency (NIEE) is defined as:
+
+$$\text{NIEE} = \frac{\text{ICT load energy consumption}}{\text{Total energy consumption of the network}}$$
+
+where:
+
+Total energy consumption of the network includes:
+
+- total input of electrical energy in network sites, excluding the energy provided by diesel/gas generators;
+- energy produced by diesel/gas consumption from fixed generators;
+- energy produced by renewable sources;
+- diesel consumption for movable generators (optional);
+- gasoline consumption of vehicles used for maintenance;
+- energy consumption of other infrastructure activities e.g., routine test on batteries, control/monitoring systems, building fire detection, building access control, lighting.
+
+NOTE – The energy consumption from transportation (vehicles used for maintenance) is complex, as the fuel used in vehicles is only part of the required energy. The consumption depends on many parameters such as vehicle type (e.g., gasoline, diesel), average consumption in Wh per km, corrections for wind, temperature, road type, altitude, speed and driver behaviour, etc., would be applied. Only a rough averaged factor can be used e.g., considering 150 Wh/km. Then it needs to define periodicity and distance as presented above to calculate a value. For example, average low-maintenance travel of 100 km/year per site leads to 15 kWh/year per site. For a small base station of 1.5 MWh per year it means 1% of its electric consumption. A more accurate assessment would need further study.
+
+# 9 Measurement methodology
+
+International standards shall be used to measure the data necessary for NIEE calculations. In cases where international standards are not available, assessment data using the metrics defined in this Recommendation shall be collected as defined below.
+
+The sum reported in the previous formula shall cover all ICT sites for which it is intended to report the indicated NIEE.
+
+Figure 6 shows measurement points for all necessary values in the NIEE formula.
+
+
+
+Figure 6: Measurement reference points for a generic installation with HV input, local generation in LV and renewable source in DC. The diagram shows a power distribution system starting with HV/MV input, stepping down via MV/LV transformers to a low-voltage bus. A local generator (ELG) and a local renewable source (ELR) are connected to this bus. The bus feeds various loads: AC no backup, UPS, and DC power feeding. AC no backup and UPS feed AC ICT loads, which are measured at EloadAC. DC power feeding feeds DC ICT loads and remote power solutions, which in turn feed Remote DC ICT loads; these are measured at EloadDC. The input energy is measured at Ei. The diagram is labeled L.1332(18)\_F06.
+
+**Figure 6 – Measurement reference points for a generic installation with HV input, local generation in LV and renewable source in DC**
+
+## 9.1 Test instrument requirements
+
+The accuracy of testing equipment shall be compliant with the requirements from clause 8.1, Table 1 of [ITU-T L.1350].
+
+Considering that energy consumption is not constant and that the presence of harmonics distorts current loads, the measurement of current needs to be true root-mean-square (rms) and then averaged to avoid this effect.
+
+NOTE – Class 1 measurement systems are for energy-measurement accuracy and should refer to Class 1 of [b-IEC 62053-21].
+
+## 9.2 Observation period
+
+Examples of factors that influence metrics for the assessment of energy efficiency on networks include:
+
+- number of users covered by a network, especially for a mobile radio network;
+- climate conditions of sites, such as temperature and humidity, and environmental requirements for air conditioning;
+
+Metrics of energy efficiency vary with seasonal and load variances. Increasing the minimum frequency of measurements provides a larger and more accurate dataset to analyse. Continuous real-time monitoring is one option to manage site efficiency so that historical trending and statistical analysis can be carried out.
+
+Other benefits of continuous real-time monitoring include early detection of unexpected variations that could indicate system issues. In cases where continuous real-time monitoring is not practical or economically justifiable, some form of repeatable, defined processes should be in place to capture metrics as often as possible for comparison purposes.
+
+When reporting metric values, network site owners should use the average NIEE measured over a one-year period to get an averaged value.
+
+For ICT sites without real-time monitoring, metrics of energy efficiency shall be collected in a repeatable fashion and the methodology documented for review.
+
+## 9.3 Load energy consumption
+
+Load energy consumption shall be assessed site by site and summed as reported in the formula below to calculate the global indicator.
+
+$$\text{Load energy consumption} = \sum_1^n (EloadAC_{site\_i} + EloadDC_{site\_i})$$
+
+ICT energy consumption shall be directly measured or reported by using the measurement defined in [b-ETSI ES 202 336-12].
+
+The measurement point of the energy consumption of AC load (EloadAC) and the energy consumption of DC load (EloadDC) should be at the power feeding interface of the telecommunication equipment considering the energy losses of the cable.
+
+Figure 6 also shows a remote powering case; this Recommendation does not detail solutions used for remote powering (e.g., remote feeding telecommunication current (RFT-C), remote feeding telecommunication voltage (RFT-V), 400 V DC) but the EloadDC, in this case, is measured at the input of equipment in remote locations. The losses due to remote powering are part of the total energy consumption, $E_i$ .
+
+Depending on the nature of the load, energy consumption shall be realized using kilowatt-hour (kWh) meters that report active energy for loads powered by AC.
+
+For loads powered by DC, the EloadDC can be the mathematical product of volts, amperes and the timeframe of the measurement duration as power delivery provides DC.
+
+Measurement of load energy: EloadAC and EloadDC, shall be reported in kWh.
+
+## 9.4 Total network energy consumption
+
+Total energy consumption shall be assessed site by site and summed as reported in the formula below to calculate the global indicator including optional contributions due to movable generators and maintenance activities.
+
+$$\text{Total network energy consumption} = EM + EMG + \sum_1^n (Ei_{site\_i} + ELG_{site\_i} + ELR_{site\_i})$$
+
+where:
+
+EM: energy generated by movable generators (optional) in kWh
+
+EMG: gasoline consumption in kWh of vehicles for maintenance (optional). This value can be assessed by conversion, in kWh, of average fuel litter consumption in a year and with a defined conversion factor
+
+$Ei_{site\_i}$ : total input electric energy of site and core-rooms excluding the energy provided by diesel/gas generators of site $n$
+
+$ELG_{site\_i}$ : energy produced by diesel/gas consumption for fixed generators of site $i$
+
+$ELR_{site\_i}$ : energy produced by renewable sources of site $i$ .
+
+The energy provided by a public grid can be measured, as LV connections to the public grid, by means of metering information provided by utility suppliers or by measurement systems, see
+
+[b-ETSI ES 202 336-12]. Locally generated energy can be measured by meters installed on site. Moreover, sensors can be used to measure site and equipment energy consumption.
+
+In some cases, due to the difficulty of analyzing large or widespread networks, a detailed measurement of energy consumption from all sites is not possible by using direct measurements, but rather by using an estimation of total energy consumption based on reports/energy bills from utilities.
+
+In this case, the energy generated locally by engines and renewable sources at different installations shall be taken into account.
+
+Measurement of total energy consumption: $E_i$ , ELG and ELR, shall be reported in kWh.
+
+NOTE – The ETSI ES 202 336-series considers an interoperable monitoring and control system for different types of infrastructure existing in a network:
+
+- [b ETSI ES 202 336-9] for alternative power system (e.g., solar wind, fuel cell);
+- [b ETSI ES 202 336-4] for AC distribution power system;
+- [b-ETSI ES 202 336-5] for AC diesel-backup generators.
+
+### 9.4.1 Total electric energy of site- and core-rooms
+
+The total energy consumption, $E_i$ , of site and core rooms shall be measured at the point reported in Figure 6; this is valid at LV level considering that normally the measurement at HV and MV is not available at the user level.
+
+The efficiency of transformers used in voltage conversion HV/MV and MV/LV should be included when considering all losses present in the installation.
+
+The energy shall be measured with a meter that is able to directly report the active energy.
+
+### 9.4.2 Energy from fixed generators
+
+Energy consumption derived from fixed generators shall be measured at the point indicated in Figure 6. The energy shall be measured with a meter that is able to directly report the active electrical energy.
+
+### 9.4.3 Energy from movable generators
+
+Energy consumption derived from mobile generators shall be measured at the output of the generator. The energy shall be measured with a meter that is able to directly report the active electrical energy.
+
+# 10 Global indicator relationship
+
+The NIEE can be used with other indicators, such as the ratio of service/equipment present in the network, to obtain a global indicator of the network that considers the facilities and telecommunication/service parts.
+
+$$NEE = \frac{\sum T_s}{\sum E_{site}} = \frac{\sum T_s}{\sum E_{Ts}} \times \frac{\sum E_{Ts}}{\sum E_{site}} = \frac{\sum T_s}{\sum E_{Ts}} \times NIEE$$
+
+Assuming:
+
+- NIEE is the global network efficiency;
+- $T_s$ is the service provided by various parts of the network;
+- $E_{site}$ is the energy consumption of a site;
+- $E_{Ts}$ is the energy consumption of telecommunication equipment.
+
+The term $\frac{\sum T_s}{\sum E_{Ts}}$ is the network telecom energy efficiency indicator and can be obtained using the methodology defined in [ITU-T L.1330].
+
+# Bibliography
+
+- [b-ETSI ES 202 336-4] ETSI ES 202 336-4 V1.1.1 (2013), *Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 4: AC distribution power system control and monitoring information model.*
+- [b-ETSI ES 202 336-5] ETSI ES 202 336-5 V1.1.1 (2010), *Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 5: AC diesel back-up generator system control and monitoring information model.*
+- [b-ETSI ES 202 336-9] ETSI ES 202 336-9 V1.1.1 (2012), *Environmental Engineering (EE); Monitoring and Control Interface for Infrastructure Equipment (Power, Cooling and Building Environment Systems used in Telecommunication Networks); Part 9: Alternative Power Systems.*
+- [b-ETSI ES 202 336-12] ETSI ES 202 336-12 V1.1.1 (2015), *Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (power, cooling and building environment systems used in telecommunication networks); Part 12: ICT equipment power, energy and environmental parameters monitoring information model.*
+- [b-IEC 60038] IEC 60038:2009, *IEC standard voltages.*
+- [b-IEC 62053-21] IEC 62053-21:2003, *Electricity metering equipment (a.c.) – Particular requirements – Part 21: Static meters for active energy (classes 1 and 2).*
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1351-201808-I_PDF-E/raw.md b/marked/L/T-REC-L.1351-201808-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..680f75792bed0e98d24eafbbb2ac3feb9e6942b3
--- /dev/null
+++ b/marked/L/T-REC-L.1351-201808-I_PDF-E/raw.md
@@ -0,0 +1,407 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1351**
+
+(08/2018)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+# --- **Energy efficiency measurement methodology for base station sites**
+
+Recommendation ITU-T L.1351
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with a red lightning bolt striking across it. To the right of the globe, the text "ITU" is written in a bold, blue font, and below it, "International Telecommunication Union" is written in a smaller, blue font.
+
+ITU logo: A globe with a red lightning bolt and the text 'ITU International Telecommunication Union'.
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+## **ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+| | |
+|--------------------------------------------------------|-------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.1351
+
+# Energy efficiency measurement methodology for base station sites
+
+## Summary
+
+Recommendation ITU-T L.1351 describes and establishes requirements for energy efficiency measurements applicable to base station sites.
+
+This Recommendation describes:
+
+- Measurement points definitions
+- Conditions of measurement
+- Instrumentation requirement
+- Reporting requirement
+- Use of a monitoring system.
+
+This Recommendation can be used as a conformity assessment standard for Recommendation ITU-T L.1350.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1351 | 2018-08-22 | 5 | 11.1002/1000/13580 |
+
+## Keywords
+
+Conformity assessment, metric measurement, radio site facilities, site energy efficiency.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2018
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-----------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Measurement point definitions ..... | 2 |
+| 7 Measurement conditions ..... | 3 |
+| 8 Instrumentation requirement..... | 3 |
+| 9 Reporting requirement ..... | 4 |
+| 10 Continuous monitoring ..... | 4 |
+| Appendix I – Laboratory measurement ..... | 5 |
+| I.1 Test set-up ..... | 5 |
+| I.2 Test results evaluation ..... | 5 |
+| Bibliography..... | 8 |
+
+
+
+## Recommendation ITU-T L.1351
+
+# Energy efficiency measurement methodology for base station sites
+
+## 1 Scope
+
+This Recommendation is applicable to base station site energy efficiency parameter measurement in line with the metric established by [ITU-T L.1350].
+
+This Recommendation describes how to realize measurement of parameters establishing requirements on:
+
+- measurement points,
+- measurement conditions, and
+- instrumentation.
+
+This Recommendation also considers continuous monitoring of the site energy efficiency parameters. It does not specify metrics, but refers to the metric defined in [ITU-T L.1350].
+
+The concepts of energy efficiency are covered by [ITU-T L.1315].
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation..
+
+[ITU-T L.1315] Recommendation ITU-T L.1315 (2017), *Standardization terms and trends in energy efficiency*.
+
+[ITU-T L.1350] Recommendation ITU-T L.1350 (2016), *Energy efficiency metrics of a base station site*.
+
+[ISO/IEC 17025] ISO/IEC 17025:2017, *General requirements for the competence of testing and calibration laboratories*.
+
+[IEC 62053-21] IEC 62053-21:2003, *Electricity metering equipment (a.c.) –Particular requirements – Part 21: Static meters for active energy (classes 1 and 2)*.
+
+# 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 base station (BS)** [b-ITU-T L.1330]: A generic term used for a network component which serves one or more cells and interfaces the user terminal (through air interface) and a radio access network infrastructure.
+
+**3.1.2 energy** [b-ITU-T L.1330]: Capacity for doing work; having several forms that may be transformed from one to another, such as thermal (heat), mechanical (work), electrical or chemical, expressed in Joules. For the purpose of this Recommendation, energy will be expressed in Watt-hours (Wh) or kilowatt-hours (kWh).
+
+**3.1.3 power** [b-ITU-T L.1330]: The rate at which energy is transmitted. Power is measured in units of Watts.
+
+**3.1.4 infrastructure (facility)** [ITU-T L.1350]: Equipment that supports the ICT equipment functionality providing energy, cooling and site ancillary activity, e.g., power delivery components and cooling system components.
+
+### 3.2 Terms defined in this Recommendation
+
+None.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+ICT Information and Communication Technology
+
+KPI Key Performance Indicator
+
+SEE Site Energy Efficiency
+
+TEC Thermoelectric Cooler
+
+## 5 Conventions
+
+This Recommendation uses the following conventions:
+
+$E_{CT}$ Base station telecommunication equipment energy consumption
+
+$E_{FE}$ Electrical energy locally generated
+
+$E_{GE}$ Electrical energy from a public grid
+
+$E_{TS}$ Total site electrical energy consumption
+
+$E_{RE}$ Electrical energy locally generated on the site by renewable energy system (solar, etc.)
+
+# 6 Measurement point definitions
+
+[ITU-T L.1350] defines site energy efficiency (SEE) as the ratio between the total energy consumption of telecommunication equipment and the total energy consumption of a site:
+
+$$SEE = \frac{E_{CT}}{E_{TS}} \times 100\%$$
+
+To calculate the SEE metric it is necessary to have the two quantities $E_{CT}$ and $E_{TS}$ .
+
+$E_{CT}$ is the energy consumption of telecommunication equipment present in the base station site under consideration during the measurement time period.
+
+$E_{CT}$ shall be measured at the input of the equipment, as close as possible to it, see Figure 1. For DC powered equipment the reference point should be the interface A defined in [b-ETSI EN 300 132-2].
+
+$E_{TS}$ is the sum of the different input energy sources that could be present at a site:
+
+- public grid ( $E_{GE}$ );
+- diesel generator present at the site or from a different type of local generator ( $E_{FE}$ );
+- renewable energy source ( $E_{RE}$ ), etc.
+
+$E_{GE}$ shall be measured at the base station site grid input or, if there are no other AC load or generators, at the input of the power feeding equipment.
+
+$E_{FE}$ shall be measured at the generator output or, if there are no other generators, at the input of the power feeding equipment.
+
+$E_{RE}$ shall be measured at the renewable energy source output (e.g., the photovoltaic array system) or, if there is no other renewable energy source, at the input of the power feeding equipment.
+
+In the case, as shown in Figure 1, in which the renewable generator directly produces DC energy in the site, $E_{FE}$ should always be measured at the output of the generator.
+
+
+
+The diagram illustrates a telecommunication site layout. A large box labeled 'Telecom site (excluding power generation equipment)' contains two main sections. The 'Telecom equipment' section includes a 'Base station' (with RF, Baseband, and Backhaul components) and 'RF feeder' units, which are connected to a 'Network connection'. The 'Site facility equipment' section includes a 'Rectifier (AC/DC)', 'Power backup', 'Security lights, etc.', and 'Air-conditioning'. Three measurement points are indicated: 'Telecom equipment electrical energy ( $E_{CT}$ )' points to the base station, 'Site electrical energy ( $E_{TS}$ )' points to the rectifier, and 'Electricity generation' points to the input of the rectifier. The diagram is labeled 'L.1351(18)\_F01' at the bottom right.
+
+Diagram of a telecommunication site showing measurement points for electrical energy. The site is divided into 'Telecom equipment' (Base station with RF, Baseband, Backhaul, and RF feeders) and 'Site facility equipment' (Rectifier (AC/DC), Power backup, Security lights, etc., and Air-conditioning). Measurement points are indicated for Telecom equipment electrical energy (E\_CT), Site electrical energy (E\_TS), and Electricity generation. The diagram is labeled L.1351(18)\_F01.
+
+**Figure 1 – Measurement points location**
+
+# 7 Measurement conditions
+
+As reported in [ITU-T L.1350], the measurement conditions can change during the measurement period. Considering that the SEE metric is defined for a real site, the measurement will be a field measurement and not a laboratory measurement, so measurement conditions including climatic, load and power grid variations should be uncontrolled.
+
+The metric considers that the measurement recording period should be one of the following:
+
+- 1 day
+- 1 week
+- 1 month
+- 1 year
+
+All necessary data, including $E_{CT}$ and $E_{TS}$ , shall be read in the same measurement time period.
+
+The measurement period for recording the parameters necessary for SEE calculation needs to be at least every 15 minutes.
+
+# 8 Instrumentation requirement
+
+To measure the quantity necessary to calculate SEE, calibrated AC energy meters and DC energy meters shall be used.
+
+General requirements for voltage and current measurement equipment are contained in [ITU-T L.1315].
+
+Energy meters used in the field shall be in line with Class 1 requirements defined by [IEC 62053-21].
+
+## 9 Reporting requirement
+
+Measurement reports shall be in line with the general requirements of [ISO/IEC 17025].
+
+The test report shall include the following information:
+
+- Site identification
+- Equipment present in the site
+- List of sensors/instrumentation used
+
+The test set-up should be fully described, including topology, the choice of offered load structures and test actions within a range of possible choices.
+
+## 10 Continuous monitoring
+
+Continuous monitoring shall be implemented using sensors integrated in the information and communication technology (ICT) equipment able to report the energy consumption or, alternatively, the voltage and current at the input of ICT equipment to establish the value of $E_{CT}$ .
+
+To determine the value of $E_{TS}$ the monitoring shall be implemented in a way that any infrastructure equipment shall give information on the energy consumption at this input.
+
+If the load ICT equipment was not being monitored as energy consumption, it is possible to use as a value of $E_{CT}$ the value of the energy at the output of power feeding equipment.
+
+Using this data, the monitoring system can register and control the SEE of a site implementing a "preventive maintenance" operation based on the anomaly variation of SEE.
+
+Figure 2 shows an example of SEE monitoring. For example, it is possible to set a key performance indicator (KPI) at a certain value to automatically show a site anomaly
+
+
+
+The figure is a line graph titled 'Example of SEE monitoring'. The Y-axis is labeled with percentages from 0% to 100% in increments of 20%. The X-axis shows dates from 10-07 to 10-20. A green line with circular markers represents the data. The values start at approximately 75% on 10-07, fluctuate between 60% and 80% until 10-14, then drop to about 55% on 10-15, rise to 65% on 10-16, drop to 50% on 10-17, stay at 50% on 10-18, rise to 55% on 10-19, and end at 65% on 10-20.
+
+| Date | Percentage (%) |
+|-------|----------------|
+| 10-07 | 75 |
+| 10-08 | 75 |
+| 10-09 | 65 |
+| 10-10 | 70 |
+| 10-11 | 75 |
+| 10-12 | 75 |
+| 10-13 | 65 |
+| 10-14 | 70 |
+| 10-15 | 55 |
+| 10-16 | 65 |
+| 10-17 | 50 |
+| 10-18 | 50 |
+| 10-19 | 55 |
+| 10-20 | 65 |
+
+L.1351(18)\_F02
+
+Line graph showing SEE monitoring data over time (10-07 to 10-20). The Y-axis represents percentage (0% to 100%). The data points fluctuate between approximately 50% and 80%.
+
+**Figure 2 – Example of SEE monitoring**
+
+# Appendix I
+
+## Laboratory measurement
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes how SEE can be used to evaluate different infrastructure/facility solutions in a laboratory before implementation on site to find the right solution for a site depending on power consumption and climate zone.
+
+The SEE shall also be used to validate site infrastructure solutions before their field implementation so the user can select the most suitable solution for a specific site based on SEE measurement results.
+
+### I.1 Test set-up
+
+In this case the load shall be simulated using some equipment as a load simulator or resistive load.
+
+The energy consumption of the solutions e.g., an outdoor power feeding equipment able to contain ICT equipment, shall be monitored with an energy meter with the instrument requirements described in clause 8.
+
+The ambient temperature during the test shall be registered.
+
+### I.2 Test results evaluation
+
+As shown in Table I.1, the test can provide an evaluation for a SEE solution as a function of temperature. For a typical solution composed of a power feeding equipment comprising an ICT load and with two different types of cooling system: one cooling system for the electronic part and a thermoelectric cooler (TEC) for the battery space. This solution structure is shown in Figure I.1.
+
+Looking at the results in Table I.1:
+
+Measure the SEE values at the following temperatures: $-25^{\circ}\text{C}$ , $-15^{\circ}\text{C}$ , $-5^{\circ}\text{C}$ , $5^{\circ}\text{C}$ , $15^{\circ}\text{C}$ , $25^{\circ}\text{C}$ , $35^{\circ}\text{C}$ , $45^{\circ}\text{C}$ .
+
+Each temperature point test needs at least 2 hours, the first hour is to ensure that the temperature is stable. Only collect the data of the second hour.
+
+It can be seen that the maximum SEE of 90% or above is available only in a temperature range from $-20^{\circ}\text{C}$ to $25^{\circ}\text{C}$ .
+
+So, if the site under consideration for development experiences climate conditions that are within that range, the solution could be implemented. If this is not the case, then it may be necessary look more carefully at climate data to check the amount of time during which the site will experience temperatures outside of that range, to have an idea of the percentage of time during which the SEE will be lower. If the percentage of time during which the SEE will be lower, then other solutions may have to be considered. The percentage of time considered depends on each solution (e.g., 50% of the time as a first approach is a good indication). The evaluation depends on the savings that can be obtained using a higher SEE and, on relevant business cases, a comparison between savings and the implementation of the solution.
+
+
+
+The diagram consists of two parts. The upper part is a technical line drawing of a tall, rectangular outdoor power feeding equipment cabinet, showing internal components such as power distribution units, batteries, and a cooling system. The lower part is a functional block diagram represented by blue rectangular blocks. On the left, a vertical column contains two blocks: 'Heat exchanger' at the top and 'TEC' at the bottom. To the right of this column, three blocks are stacked vertically: 'Power feeding' at the top, 'Load' in the middle, and 'Battery' at the bottom. The label 'L.1351(18)\_FI.1' is located at the bottom right of the functional diagram.
+
+Technical drawing and functional block diagram of outdoor power feeding equipment.
+
+**Figure I.1 – An example of an outdoor power feeding equipment**
+
+**Table I.1 – Examples of SEE values**
+
+| Ambient temperature | AC input consumption | Main equipment (Loads) consumption | Equipment cooling unit consumption | TEC consumption | SEE |
+|----------------------------|-----------------------------|-------------------------------------------|-------------------------------------------|------------------------|------------|
+| 45 | 3250 | 2800 | 40 | 289 | 86.15% |
+| 35 | 3256 | 2790 | 27 | 298 | 85.69% |
+| 25 | 3140 | 2810 | 19 | 207 | 89.49% |
+| 15 | 3000 | 2850 | 13.8 | 41 | 95.00% |
+| 5 | 3020 | 2900 | 12.049 | 40 | 96.03% |
+| -5 | 3047.2 | 2930 | 8.7 | 48 | 96.15% |
+| -15 | 3162 | 2910 | 9.4 | 84 | 92.03% |
+| -25 | 3304 | 2890 | 8.5 | 244 | 87.47% |
+
+NOTE – A SEE data temperature test at -35°C and 50°C may also be required depending on real site conditions.
+
+## Bibliography
+
+- [b-ITU-T L.1330] Recommendation ITU-T L.1330 (2015), *Energy efficiency measurement and metrics for telecommunication networks*.
+- [b-ITU-T L.1340] Recommendation ITU-T L.1340 (2014), *Informative values on the energy efficiency of telecommunication equipment*.
+- [b-ITU-T L.1410] Recommendation ITU-T L.1410 (2014), *Methodology for environmental life cycle assessments of information and communication technology goods, networks and services*.
+- [b-IEC 60050-131] IEC 60050-131:2002, *International Electrotechnical Vocabulary – Part 131: Circuit theory*.
+- [b-ETSI ES 202 336-12] ETSI ES 202 336-12 (2015), *Environmental Engineering (EE); Monitoring and control interface for infrastructure equipment (power, cooling and building environment systems used in telecommunication networks); Part 12: ICT equipment power, energy and environmental parameters monitoring information model*.
+- [b-ETSI EN 300 132-2] ETSI EN 300 132-2 (2016), *Environmental Engineering (EE); Power supply interface at the input of Information and Communication Technology (ICT) equipment; Part 2: -48 V Direct Current (DC)*. [http://www.etsi.org/deliver/etsi\\_en/300100\\_300199/30013202/02.05.01\\_60/en\\_30013202v020501p.pdf](http://www.etsi.org/deliver/etsi_en/300100_300199/30013202/02.05.01_60/en_30013202v020501p.pdf)
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3f7d089054e882ed7ca4769ca321e798f225675b
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/07b17a620c75522d53916a11e12d1bff_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11f8cc828742f341df08affd958195b429c08c388186e6c4f87c43a5ab4495a5
+size 106284
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/36ac3e730a00d3f42d3400f5709f641a_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/36ac3e730a00d3f42d3400f5709f641a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1e151def60dbc2f23204e0ec8d14b1c75a62a26f
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/36ac3e730a00d3f42d3400f5709f641a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dd5622626dcc4cf8a801da763c55db59c86365cc4678c7942744a756ac7bc63d
+size 111107
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/7c1f9e78e0f033d391b687f1652f6e47_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/7c1f9e78e0f033d391b687f1652f6e47_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ae245e4340ca39d0446c1d340d5b0381cfa7537
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/7c1f9e78e0f033d391b687f1652f6e47_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1556239df55a2033684471b0ddc9b93d48919c0d5b53632e88b0393122f472e2
+size 103493
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0e57e540bba5f1a430b0c2b9fc5c2c59bcb64d0d
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:464bf0cb2b56236d2229097f5e3744e3b291d7163c0094968e33b1caa52cc720
+size 103882
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5d8312f847d1469f2c1bb283546a9f6244297348
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7ec7b942e42cef8c669bdec97eb612df39c2c9b4f10b8a24eb6d335a3eef6214
+size 132227
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/L/T-REC-L.1385-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..609d31c1f4ebb96513c012f2102b5910a85fff60
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c0bdef1554424e983f32af27271b226f514c74b3dd6bb2b980f0b979a87eedea
+size 102641
diff --git a/marked/L/T-REC-L.1385-202512-I_PDF-E/raw.md b/marked/L/T-REC-L.1385-202512-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..6612397e9469fb75bd5e8edf3a070c6210b5db15
--- /dev/null
+++ b/marked/L/T-REC-L.1385-202512-I_PDF-E/raw.md
@@ -0,0 +1,350 @@
+
+
+## Recommendation
+
+# **ITU-T L.1385 (12/2025)**
+
+SERIES L: Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant
+
+Energy efficiency, smart energy and green data centres
+
+---
+
+## **Smart energy solutions for the manufacturing industry**
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with white grid lines and a stylized 'ITU' text in blue, with a white lightning bolt symbol integrated into the letter 'T'.
+
+ITU logo
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+### **Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant**
+
+| | |
+|----------------------------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | L.100-L.199 |
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+| OPTICAL INFRASTRUCTURES | L.200-L.299 |
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+| MAINTENANCE AND OPERATION | L.300-L.399 |
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000-L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200-L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300-L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400-L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500-L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600-L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700-L.1799 |
+| ENVIRONMENTAL SUSTAINABILITY OF ARTIFICIAL INTELLIGENCE AND EMERGING ICT SYSTEMS | L.1800-L.1899 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+### Recommendation ITU-T L.1385
+
+## Smart energy solutions for the manufacturing industry
+
+## Summary
+
+Recommendation ITU-T L.1385 provides smart energy solutions, which can be utilized in the manufacturing industry. It defines the framework for industrial smart energy management system for different manufacturing scenarios. This Recommendation also provides use cases and guidance for application of smart energy solutions to the manufacturing industry. On the premise of ensuring energy reliability, this Recommendation provides reference for the industrial sectors to improve energy efficiency levels in various aspects such as green energy transformation, energy monitoring, management, scheduling and decision-making.
+
+## History \*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T L.1385 | 2025-12-14 | 5 | 11.1002/1000/16638 |
+
+## Keywords
+
+Digital technology, energy consumption, industrial sector, smart energy
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2026
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|--------------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Overview of smart energy solutions for manufacturing industry..... | 2 |
+| 7 Guidance for applying smart energy solutions to manufacturing industry..... | 3 |
+| 7.1 General ..... | 3 |
+| 7.2 Promoting diversified energy utilization structures ..... | 3 |
+| 7.3 Dynamic management of accurate energy consumption in production ..... | 4 |
+| 7.4 Strengthen enterprise operational control..... | 5 |
+| 8 Use cases of smart energy solutions for manufacturing industry ..... | 6 |
+| 8.1 The industrial smart energy case of electrical equipment manufacture ..... | 6 |
+| 8.2 The industrial smart energy case of a smart factory..... | 7 |
+
+
+
+## Recommendation ITU-T L.1385
+
+## Smart energy solutions for the manufacturing industry
+
+## 1 Scope
+
+This Recommendation provides the overview of smart energy solutions and framework of industrial smart energy management system that improve energy efficiency and reduce GHG emissions in manufacturing industry. It also provides guidance and application use cases which applied in different scenarios such as electrical equipment manufacturing and smart factory in the manufacturing industry.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+None.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 digital application layer:** A collection of application modules built on the platform layer for specific business scenarios.
+
+NOTE – Through the in-depth adaptation of digital technologies to industrial energy consumption scenarios, this layer enables the scenario-based implementation of energy management and value conversion.
+
+**3.2.2 digital infrastructure layer:** A collection of basic hardware and network facilities that support the operation of the industrial smart energy system, including sensing terminals, communication networks and computing and storage devices.
+
+NOTE – This layer provides underlying support capabilities for energy data collection, transmission and storage.
+
+**3.2.3 digital platform layer:** A virtual environment built on digital technology that enables the collection, processing, storage and dissemination of information.
+
+NOTE – This layer realizes the in-depth integration of energy flow and information flow, and provides standardized data services and computing power support for upper-layer applications.
+
+**3.2.4 industrial smart energy management system:** Intelligent system that integrates data collection, monitoring, analysis, prediction and optimization for the manufacturing industry.
+
+NOTE – This system provides accurate energy management solutions for the industrial sectors through real-time monitoring of energy conditions combined with big data analysis technology.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|------------------------------------------|
+| AI | Artificial intelligence |
+| GHG | Greenhouse Gas |
+| ICT | Information and Communication Technology |
+| IoT | Internet of Things |
+
+# 5 Conventions
+
+None.
+
+# 6 Overview of smart energy solutions for manufacturing industry
+
+Smart energy solutions for manufacturing industry are important to reduce GHG emissions. Industrial smart energy management systems based on technologies such as Internet of things (IoT), big data, and artificial intelligence (AI), tailored to the characteristics of the manufacturing sector are crucial to manage various smart energy solutions effectively. To implement these smart energy solutions, it is necessary to build an industrial smart energy management system, which consists of three layers: the digital infrastructure layer, the digital platform layer and the digital application layer. Each layer performs the functions of energy monitoring, energy consumption analysis, energy-saving management and decision-making, achieving online monitoring, centralized management and optimized dispatching of energy. The specific framework of the industrial smart energy management system is shown in Figure 1.
+
+
+
+The diagram illustrates the framework of an industrial smart energy management system, organized into three hierarchical layers:
+
+- Digital application layer (Top):** Contains six functional blocks: Energy consumption assessment, Demand forecast, Energy saving potential analysis, Energy optimization strategy, Energy dynamic control, and Intelligent scheduling.
+- Digital platform layer (Middle):** Contains four data processing blocks (Energy data storage, Energy data analysis, energy-saving analysis, Smart decision-making) and five technology blocks (IOT, Big data, Cloud computing, AI, Machine learning).
+- Digital infrastructure layer (Bottom):** Contains one data transmission block (Data collection and transmission: Network, Gateway, Intelligence, Sensor, Controller) and four physical/energy blocks (Clean energy, Power transmission and distribution, Industrial process, Sensors), each accompanied by a representative icon.
+
+Upward-pointing arrows between the layers indicate the flow of data and information. The entire structure is flanked by labels: 'Industrial smart energy management system' on the left and 'Standard specification system' on the right. A small code 'L.1385(25)' is visible in the bottom right corner of the diagram area.
+
+Figure 1 – Framework of industrial smart energy management system. The diagram shows a three-layer structure: Digital application layer (top), Digital platform layer (middle), and Digital infrastructure layer (bottom). The Digital application layer includes Energy consumption assessment, Demand forecast, Energy saving potential analysis, Energy optimization strategy, Energy dynamic control, and Intelligent scheduling. The Digital platform layer includes Energy data storage, Energy data analysis, energy-saving analysis, Smart decision-making, IOT, Big data, Cloud computing, AI, and Machine learning. The Digital infrastructure layer includes Data collection and transmission (Network, Gateway, Intelligence, Sensor, Controller), Clean energy, Power transmission and distribution, Industrial process, and Sensors. The entire system is labeled 'Industrial smart energy management system' on the left and 'Standard specification system' on the right. Arrows indicate data flow from bottom to top between layers.
+
+**Figure 1 – Framework of industrial smart energy management system**
+
+The system deploys intelligent sensors on manufacturing equipment and energy meters to collect real-time energy consumption data (including solar power, wind power, electricity, water, gas and heat). It builds a multi-dimensional database by integrating this data with information such as manufacturing processes and environmental parameters.
+
+Then the system uses intelligent algorithms to conduct in-depth data analysis and accurately identify the operating status of equipment and energy consumption levels, while predicting energy consumption trends.
+
+Finally, based on the results of data analysis, the system dynamically matches energy supply with manufacturing demand to achieve efficient energy utilization. The system can intelligently adjust the operating period of high-energy-consuming equipment to maintain the peak power consumption under the limit. For distributed energy sources such as solar power, wind power and energy storage, the system dynamically adjusts the proportion of energy used to achieve efficient consumption of clean energy and coordinated grid connection. Additionally, the system can perform energy diagnosis based on energy consumption data, providing data support for energy-saving renovations and green production decisions, and promoting the green transformation of the industry.
+
+# **7 Guidance for applying smart energy solutions to manufacturing industry**
+
+## **7.1 General**
+
+In some cases, the level of energy efficiency of manufacturing industry applications cannot be further optimized due to a lack of information and communication technology (ICT). Thus, it is crucial that manufacturing industry utilizes ICT to improve the energy efficiency. They are key enablers for driving smart energy solutions in manufacturing industry applications. By facilitating the adoption of clean energy, regional customization network communication and the IoT, energy utilities in manufacturing industry can be improved and optimized. Smart energy solutions can also promote conversion to all kinds of renewable energy sources such as solar, wind power and chemical power, increase the proportion of clean energy for electric power generation, optimize energy feeding structure and improve overall energy efficiency. Depending on the differences in application scenarios, smart energy solutions can be combined with specific industrial scenarios in three major areas, including diversified energy utilization, dynamic management of precise energy consumption for production, and improvement of operational capabilities.
+
+## **7.2 Promoting diversified energy utilization structures**
+
+Through the optimization of energy utilization, digital technologies can reduce the over-dependency on single energy sources in traditional industries and promote diversified energy use in the manufacturing industry.
+
+The smart energy system for the manufacturing industry can intelligently manage the coordinated supply of traditional energy and clean energy, achieving multi-energy coordinated control. Combined with the peak-valley electricity price difference and the fluctuation characteristics of renewable energy, the system can implement the power supply strategy of "source-grid-load-storage", reducing energy costs. Meanwhile, based on the characteristics of regional energy, it formulates regional energy scheduling strategies.
+
+Figure 2 illustrates the intelligent microgrid system constructed by an automotive manufacturing enterprise, which has installed solar power and energy storage. The system intelligently regulates the proportion of clean energy applications, ensuring the stability and economy of the energy system.
+
+
+
+Figure 2: Multi-energy coordination system in the manufacturing industry. The diagram shows a factory with solar panels on the roof labeled 'Solar capacity: 500 MWp'. A large digital screen displays the 'Smart energy management platform' with data: 85%, ±30, ±30 MW, and 320,000. Below the screen, there are '200 MWh flow storage' units and 'Vanadium flow battery storage' units. Blue lines represent energy flow from the solar panels and storage units to a manufacturing line with robots. A car is shown on the screen, and several cars are parked outside the factory. The text 'L.1385(25)' is in the bottom right corner.
+
+**Figure 2 – Multi-energy coordination system in the manufacturing industry**
+
+## 7.3 Dynamic management of accurate energy consumption in production
+
+The industrial smart energy management system monitors the energy consumption data of all manufacturing processes in real time. Through intelligent analysis, the system can dynamically match energy supply with manufacturing demand and identify high-energy-consumption processes. Meanwhile, by combining historical operating data with real-time operating conditions, it predicts the trend of energy consumption and formulates control strategies in advance. The system enables the manufacturing industry to make more scientific and flexible decisions on energy consumption, helping the manufacturing industry reduce energy waste.
+
+Figure 3 presents the intelligent application case in the manufacturing process of a battery manufacturing enterprise. The enterprise has deployed a large number of sensors in all key processes to collect manufacturing data in real time which will be analyzed by the industrial smart energy management system later. Then, the system dynamically optimizes the operating parameters of the manufacturing processes based on the analysis results, and thereby improves energy utilization efficiency.
+
+
+
+The diagram illustrates a three-layer system for intelligent applications in manufacturing processes:
+
+- Sensor network layer (Production process layers):** This layer is represented by a 3D model of a production line. It includes labels for "Production requirements", "Equipment temperature", and "Production load".
+- Data processing (Deep learning):** This layer is represented by a digital interface showing a neural network diagram and data visualizations. It receives input from the sensor network layer and provides output to the application layer.
+- Application (Full-process waste heat cascade utilization system):** This layer is represented by a schematic diagram of a heat exchange system. It includes labels for "Heat" and "Heat exchange".
+
+Arrows indicate a sequential flow from left to right: Sensor network layer → Data processing → Application. A feedback loop labeled "Dynamic production" connects the Application layer back to the Data processing layer. The text "L.1385(25)" is visible in the bottom right corner.
+
+Figure 3: Intelligent applications in manufacturing processes. The diagram illustrates a three-layer system: Sensor network layer (Production process layers), Data processing (Deep learning), and Application (Full-process waste heat cascade utilization system).
+
+**Figure 3 – Intelligent applications in manufacturing processes**
+
+## 7.4 Strengthen enterprise operational control
+
+In terms of enhancing the operational capabilities of the manufacturing industry, intelligent technology can break down barriers to energy management and promote collaboration in energy management. By establishing collaborative management modes that cover all departments, energy data sharing can be achieved to improve management efficiency.
+
+Figure 4 illustrates the application of operational capability improvement for an electrical equipment manufacturing enterprise. By building a digital platform layer of industrial smart energy management system, the enterprise has achieved efficient collaborative linkage across departments and enhanced energy management efficiency.
+
+
+
+Intelligent energy cross business collaboration and low carbon transformation
+
+**Production facilities**
+
+Business units Renewable energy/Production facilities Supply chain R&D, data analytics Collaboration sustainability
+
+**Monthly carbon emissions (2023)**
+
+● Before ● Current
+
+400
+300
+200
+100
+0
+
+0 10 20 30 40 50 60 70 80 90 100
+
+50,000
+
+**Carbon reduction progress: Of target**
+
+75% of target
+
+Source systems → IoT devices → ERP → CRM → Integrate layer → ETL tools → Target → Management intelligence
+
+Input historical energy data → Optimization model (Genetic algorithm) → Feedback (Real-time usage) → Corbonx loop (Platform) → Output: Energy application plan
+
+L.1385(25)
+
+Figure 4: An example of intelligent application in operational management. The diagram shows a pyramid of production facilities at the top, supported by five business units: Business units, Renewable energy/Production facilities, Supply chain, R&D, data analytics, and Collaboration sustainability. Below this, a line graph shows monthly carbon emissions (2023) with 'Before' and 'Current' data points, a gauge showing 75% of target carbon reduction progress, a flowchart of data integration from source systems to management intelligence, and a circular process diagram for energy optimization using a genetic algorithm and Corbonx loop platform.
+
+Figure 4 – An example of intelligent application in operational management
+
+# 8 Use cases of smart energy solutions for manufacturing industry
+
+## 8.1 The industrial smart energy case of electrical equipment manufacture
+
+Against the backdrop of the profound transformation of the global energy structure and the drive for energy conservation and carbon reduction, electrical equipment manufacture faces several challenges in its low-carbon transformation. These include mismatches between energy supply and demand caused by the intermittency and volatility of renewable energy, difficulties in integrating and analyzing heterogeneous data across energy systems, and a lack of intelligent means for energy management.
+
+To achieve rapid low-carbon transformation, the industrial smart energy management system shown in Figure 5 has been built. The system collects sensor data from solar power generation systems, energy storage systems and electrical equipment. Then the system accurately predicts and intelligently schedules the solar power generation and electricity load, which helps the electrical equipment manufacture achieve the coordinated control of multi-source data, including solar power generation, energy storage and electrical equipment, and improve energy utilization efficiency.
+
+
+
+Diagram of the Industrial smart energy management system at an electrical equipment manufacture. The system is organized into four horizontal layers. The top layer shows the 'Power grid' and 'Park microgrid' connected by a double-headed arrow. The second layer features the 'Industrial smart energy management system' (central pink box) connected to 'Photovoltaic prediction', 'Load prediction', 'Photovoltaic storage fluctuation regulation', and 'Energy comprehensive regulation' on the left, and 'Zero-carbon park', 'Demand-side response', 'Smart distribution network 5G', and 'AC-DC microgrid' on the right. The third layer includes 'Energy data', 'Production information', 'Meteorological data', and 'Power grid data'. The bottom layer consists of 'Photovoltaic equipment', 'Energy storage equipment', 'Charging facilities', and 'Power distribution equipment'. A small code 'L.1385(25)' is visible at the bottom right.
+
+**Figure 5 – Industrial smart energy management system at an electrical equipment manufacture**
+
+Since the implementation of the project, the local consumption rate of new energy has significantly increased. At the same time, energy costs have reduced and carbon emissions have significantly reduced.
+
+## 8.2 The industrial smart energy case of a smart factory
+
+The smart factory has been committed to achieving net-zero emissions and more sustainable operations by combining data-driven decision-making with innovative energy management. The factory has installed a solar power generation system with a peak capacity of 250 kW, which can generate 220 MWh of solar power annually. More than 100 energy monitoring points have been deployed and connected to the energy management system. This system can analyze energy consumption and costs in real time, helping the factory accurately understand its energy usage and providing support for energy use decision-making.
+
+Through the implementation of smart energy measures, the smart factory has achieved remarkable results in energy efficiency and sustainable development, serving as a reference case for other manufacturing factories. This is shown in Figure 6.
+
+
+
+Annual CO2 emissions reduced by approximately 636 tons
+
+50% reduction in mixed set plastic waste
+
+30% increase in energy efficiency
+
+20% increase in recycling rate
+
+Aerial view of a modern factory complex with solar panels on the roof and surrounding land. Overlaid text shows sustainability targets: Annual CO2 emissions reduced by approximately 636 tons, 50% reduction in mixed set plastic waste, 30% increase in energy efficiency, and 20% increase in recycling rate.
+
+L.1385(25)
+
+Figure 6 – "Zero Emission Vision" of the smart factory
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1390-202208-I_PDF-E/raw.md b/marked/L/T-REC-L.1390-202208-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..40c9e439bcd405f28494a760d455244e0b010dd2
--- /dev/null
+++ b/marked/L/T-REC-L.1390-202208-I_PDF-E/raw.md
@@ -0,0 +1,685 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1390**
+
+(08/2022)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+Energy efficiency, smart energy and green data centres
+
+---
+
+**Energy saving technologies and best practices
+for 5G radio access network (RAN) equipment**
+
+Recommendation ITU-T L.1390
+
+# ITU-T L-SERIES RECOMMENDATIONS
+
+## ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
+
+| | |
+|---------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000–L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200–L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300–L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400–L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500–L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600–L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700–L.1799 |
+
+For further details, please refer to the list of ITU-T Recommendations.
+
+## Recommendation ITU-T L.1390
+
+## Energy saving technologies and best practices for 5G radio access network (RAN) equipment
+
+## Summary
+
+The rapid development and commercialization of 5G radio communication technology is further accelerating 5G network construction. While it is an important enabler for the digitalization of other industries and thereby contributes to significant energy savings and emission reductions, it is also important to consider the energy consumption of the 5G network infrastructure itself.
+
+Recommendation ITU-T L.1390 identifies energy saving potentials, describes energy saving principles and technologies for 5G RAN and related equipment, and provides best practice recommendations on when and how these technologies should be used and controlled, thereby reducing 5G RAN energy consumption, saving operational costs and making 5G RAN a green and high-efficiency network.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1390 | 2022-08-13 | 5 | 11.1002/1000/15029 |
+
+## Keywords
+
+5G, AI, best practice, energy saving, RAN.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2022
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|---------------------------------------------------------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Overview of energy consumption of 5G ..... | 3 |
+| 6.1 Where is energy consumed? ..... | 3 |
+| 6.2 Baseline and variable power consumption ..... | 3 |
+| 7 Energy saving design principles ..... | 4 |
+| 7.1 Dynamic scaling ..... | 4 |
+| 7.2 Shutdown capabilities..... | 5 |
+| 7.3 Trade-offs ..... | 5 |
+| 8 Energy saving technologies for 5G RAN ..... | 6 |
+| 8.1 Time-domain energy saving ..... | 6 |
+| 8.2 Spatial-domain energy saving ..... | 7 |
+| 8.3 Frequency-domain energy saving..... | 7 |
+| 8.4 Power-domain energy saving ..... | 8 |
+| 9 AI-based energy saving for 5G RAN ..... | 8 |
+| 9.1 AI technology ..... | 9 |
+| 9.2 Energy saving based on AI..... | 9 |
+| 9.3 Architecture of AI-based energy saving..... | 10 |
+| Appendix I – Example of 5G power-domain energy saving practices – Beam optimization energy saving..... | 11 |
+| Appendix II – Example of 5G power-domain energy saving practice – Ultra-large-scale antenna array with beam pattern optimization..... | 13 |
+| Appendix III – Example of a 5G power-domain energy saving practice – High gain antenna-lens antenna ..... | 14 |
+| Appendix IV – Example of energy saving practice based on AI – Service awareness energy saving for 4G/5G coordination ..... | 18 |
+| Bibliography..... | 21 |
+
+## Introduction
+
+The rapid development and commercialization of 5G radio communication technology is further accelerating 5G network construction. While it is an important enabler for the digitalization of other industries and thereby contributes to significant energy savings and emission reductions [b-GeSI] [b-GSMA-1], it is also important to consider the energy consumption of the 5G network infrastructure itself. 5G will use wider bandwidths, more antennas and new frequency bands in order to boost the capacity of the mobile communication network and facilitate new use cases such as massive machine type communications (mMTC) and ultra-reliable low latency communications (uRLLC). Consequently, with the roll-out of 5G on top of existing network generations, network energy consumption will become an important operating cost for mobile network operators (MNOs).
+
+Energy saving and emission reduction is not only the social responsibility of telecommunications operators but also inherent development needs of operators to continuously reduce electricity costs and improve market competitiveness. Hence, energy saving technologies and best practices for 5G RAN equipment are needed.
+
+## Recommendation ITU-T L.1390
+
+## Energy saving technologies and best practices for 5G radio access network (RAN) equipment
+
+## 1 Scope
+
+This Recommendation identifies energy saving potentials, describes energy saving principles and technologies for 5G RAN and related equipment, and provides best practice recommendations on when and how these technologies should be used and controlled to reduce 5G RAN energy consumption.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a standalone document, the status of a Recommendation.
+
+[ITU-T F.749.13] Recommendation ITU-T F.749.13 (2021), *Framework and requirements for civilian unmanned aerial vehicle flight control using artificial intelligence*.
+
+[ISO/IEC 13273-1] ISO/IEC 13273-1:2015, *Energy efficiency and renewable energy sources – Common international terminology – Part 1: Energy efficiency*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 artificial intelligence (AI)** [ITU-T F.749.13]: An interdisciplinary field, usually regarded as a branch of computer science, dealing with models and systems for the performance of functions generally associated with human intelligence, such as reasoning and learning.
+
+**3.1.2 big data** [b-Viktor]: A term that describes the large volume of data – both structured and unstructured – that inundates a business on a day-to-day basis. Big data can be analysed for insights that lead to better decisions and strategic business moves.
+
+**3.1.3 energy consumption** [ISO/IEC 13273-1]: Quantity of energy applied.
+
+**3.1.4 energy efficiency** [ISO/IEC 13273-1]: The ratio or other quantitative relationship between an output of performance, service, goods or energy, and an input of energy.
+
+**3.1.5 energy saving** [ISO/IEC 13273-1]: Reduction of energy consumption following implementation of an energy performance improvement action.
+
+### 3.2 Terms defined in this Recommendation
+
+None.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|--------------------------------------------|
+| 2G | 2nd Generation of wireless networks |
+| 3G | 3rd Generation of wireless networks |
+| 4G | 4th Generation of wireless networks |
+| 5G | 5th Generation of wireless networks |
+| AAU | Active Antenna Unit |
+| AI | Artificial Intelligence |
+| ARIMA | Auto-Regressive Integrated Moving Average |
+| BS | Base Station |
+| CRS | Cell-specific Reference Signal |
+| EIRP | Equivalent Isotropic Radiated Power |
+| KPI | Key Performance Indicator |
+| LSTM | Long Short-Term Memory |
+| LTE | Long Term Evolution |
+| MDT | Minimization of Drive Test |
+| MIMO | Multiple Input Multiple Output |
+| mMTC | massive Machine Type Communications |
+| MNO | Mobile Network Operator |
+| MR | Measurement Report |
+| NR | New Radio |
+| O&M | Operation and Management |
+| OFDM | Orthogonal Frequency Division Multiplexing |
+| PA | Power Amplifier |
+| PRB | Physical Resource Block |
+| PM | Performance Measurement |
+| RAN | Radio Access Network |
+| RF | Radio Frequency |
+| RRC | Radio Resource Control |
+| RRU | Remote Radio Unit |
+| RSRP | Reference Signal Received Power |
+| SA | StandAlone |
+| SINR | Signal to Interference plus Noise Ratio |
+| TA | Timing Advance |
+| UE | User Equipment |
+| uRLLC | ultra-Reliable Low Latency Communications |
+
+## 5 Conventions
+
+None.
+
+## 6 Overview of energy consumption of 5G
+
+### 6.1 Where is energy consumed?
+
+To determine the potential for energy saving and emission reduction in a mobile network, it is necessary to understand the power consumption distribution in the network. In 2015, mobile networks worldwide consumed 90 TWh of electricity, a figure that is expected to grow to ~130 TWh in 2030 [b-ITU-T L.1470]. The majority of this is consumed by the radio access network (RAN), i.e., the base station (BS) sites.
+
+In the RAN, the power consumption of a BS site is divided into two parts: the power consumption of the main equipment (BS) and the power consumption of auxiliary equipment (such as air conditioners). For an outdoor site, the power consumption of the site is mainly from the main equipment, while for indoor sites the auxiliary equipment can make up a significant part.
+
+Main equipment (BS) power consumption can be divided into the following two types: compute power consumption, which refers to the power consumed by the baseband processing, including the power consumption of digital part processing, management and control, communication with the core network and other BSs; and transmission power consumption, which refers to the power consumed by the power amplifier (PA) and radio frequency (RF) parts.
+
+The greater the output power of the BS, the larger the share of the BS power consumption that is transmission power consumption, and the larger the share of the transmission power consumption that is PA power consumption [b-Auer]. However, 5G introduces massive MIMO where the number of RF channels is increased significantly, which means that a larger share of the transmission power consumption comes from the other RF parts, even though the PA still is dominating. With lower output powers, the relative share of the compute power consumption is increasing, and so is the non-PA part of the transmission power consumption [b-Debaille].
+
+### 6.2 Baseline and variable power consumption
+
+Power consumption at the site, BS or equipment level can be classified into baseline power consumption and variable power consumption. Simply put, the power consumption that does not vary with the load is called baseline power consumption, and the power consumption that is positively related to the load is called variable power consumption. For example, the power consumption of the PA varies with the load. However, when the load is zero, the power consumption of the PA is not zero because the PA power consumption can be divided into baseline power consumption and variable power consumption.
+
+In general, we can approximate the power consumption model with a simple first-order linear model [b-Holtkamp]:
+
+$$P = a \times T + b$$
+
+where $P$ represents the total power consumption, $a$ represents the power consumption variation, $T$ represents the traffic load, $a \times T$ represents the variable power consumption, and $b$ represents the baseline power consumption.
+
+The higher the percentage of variable power consumption, the stronger the dynamic capability of the equipment. In addition to the baseline power consumption $b$ , the slope $a$ of the curve is also important. The slope determines the magnitude of the variable power consumption change with the load. Therefore, the primary function shown in Figure 1 is not an ideal scenario. The concave curve of the origin is passed. For example, a quadratic curve $P = a \times T^2$ has better dynamic capability than a primary curve.
+
+
+
+Figure 1: Linear approximation model for power consumption. The graph shows Power on the y-axis and Load (0%, 50%, 100%) on the x-axis. Two lines are plotted: 'Actual' (solid orange line) and 'Ideal' (dashed green line). The 'Ideal' line starts at the origin (0,0) and increases linearly to a point at 100% load. The 'Actual' line starts at a higher power level at 0% load and increases linearly to the same point at 100% load. The vertical distance between the two lines at 0% load is labeled 'Baseline part', and the vertical distance between the 'Ideal' line and the 'Actual' line at 100% load is labeled 'Variable part'. A horizontal dashed line extends from the 100% load point to the y-axis. The label 'L.1390(22)' is at the bottom right.
+
+**Figure 1 – Linear approximation model for power consumption**
+
+To improve the variable power consumption capability of an item of equipment, the hardware capability must be improved to reduce the proportion of baseline power consumption. On the other hand, when no data is transmitted, the energy saving shutdown capability of a component corresponding to the baseline power consumption is improved. Current mainstream RAN energy saving technologies (see clause 8) mainly reduce baseline power consumption $b$ , and the improvement of slope $a$ depends on the continuous evolution of the hardware. In a field network, the BS operates in light load and medium load most of the time. Therefore, the performance of this power consumption curve under low and medium loads has the greatest impact on the actual daily energy consumption of the network. In addition, low load and medium load are the main scenarios where the energy saving feature takes effect.
+
+## 7 Energy saving design principles
+
+From the energy consumption analysis in clause 6, it is possible to formulate some energy saving design principles.
+
+### 7.1 Dynamic scaling
+
+The dynamic capability is the capability of scaling power consumption with real-time changes of service loads. The dynamic capability is decomposed into the capability of scaling resource consumption with changes of service loads, and the ability of equipment power consumption to scale as resource consumption changes.
+
+- 1) **Resource on-demand scaling:** Based on network KPIs and user QoS requirements, time-, space- and frequency-based resource occupation and air-interface power resource allocation are adjusted, implementing real-time dynamic scaling. Especially in low and medium load scenarios, reducing resource overhead through proper scheduling is a key path for energy saving.
+
+The evolution of wireless networks is a process of expanding network capacity and resources to cope with increasing service requirements. The resources are increased to meet the peak capacity of the network. However, traffic is tidal, and the proportion of peak scenarios in a day is not so high. It is therefore necessary to adjust the resources to the required demand.
+
+- 2) **Power consumption scales with resources:** When resource consumption decreases, equipment power consumption should also decrease. The resource herein may be a bandwidth, a quantity of carriers, a quantity of channels, a transmit power or the like. For example, transmission power consumption varies with the number of RF channels and PA
+
+output power, while compute power consumption typically varies with the bandwidth and the quantity of channels [b-Debaillie].
+
+### 7.2 Shutdown capabilities
+
+When scaling power consumption with resources, the static power consumption may become an obstacle. In other words, when scaling down resources the power consumption reaches a level (the static power consumption) where it does not scale any more. In such cases, a shutdown capability of the hardware component(s) is desirable, i.e., a deactivation of one or more components which decreases the static power consumption stepwise. A drawback with this is that the component is taken out of service, and reactivating it will cause a delay.
+
+The energy saving gain from shutdown capabilities depends on three dimensions as illustrated in Figure 2. These are $S$ , scenario (shutdown scenario), $T$ , time (shutdown duration) and $D$ , depth (shutdown depth). An improvement in shutdown scenario, shutdown duration and shutdown depth leads to an improvement in overall energy saving capability.
+
+
+
+Figure 2: Three dimensions of shutdown capabilities. A 3D coordinate system with three axes: S (Shutdown scenarios), T (Shutdown duration), and D (Shutdown depth). The S axis is vertical, the T axis is horizontal to the right, and the D axis is diagonal down-left. A cube is drawn in the first octant, with its edges along the axes. The label 'L.1390(22)' is present near the T axis.
+
+Figure 2 – Three dimensions of shutdown capabilities
+
+An extended shutdown scenario can be that parameters are adjusted such that the shutdown can be applied more often. An improvement of the shutdown duration can be achieved by reducing the common information overhead in no load or light load scenarios, or performing aggregation scheduling for small-packet services. Finally, the shutdown depth is related to how many hardware components can be deactivated.
+
+Furthermore, the three dimensions are not independent, but are mutually coupled and mutually constrained. When one dimension is strongly expanded, the other two dimensions may be affected. For example, increasing the shutdown depth increases the energy saving gain at the time when the shutdown takes effect, but increasing the shutdown depth may increase the wakeup duration [b-Debaillie]. The increase of the wakeup duration affects the application scenarios and the possibility of entering the sleep state. The overall gain of the whole day may not be the optimal state. Therefore, these three dimensions need to be considered comprehensively in the design of the solution and finding a good balance between them should be strived for.
+
+### 7.3 Trade-offs
+
+Energy saving involves various trade-offs, as discussed in clause 7.2. Another trade-off is between **network performance and energy saving**. Based on the impact on performance, many energy saving technologies are lossy as they scale resources, and the number of resources is closely related to performance. Therefore, it is difficult to achieve lossless performance. On the other hand, there is a large margin for network experience in off-peak hours, such as night. If the margin is properly squeezed out, energy saving can be harvested. However, how to squeeze this space will involve another issue, the qualitative and quantitative analysis of the impact of various energy saving measures on performance. In many scenarios, this impact cannot be accurately modelled in a white
+
+box manner. Although certain parameter thresholds are designed for most features to control the impact on performance, it is difficult to provide accurate guidance on how to adjust parameters. AI might be a tool to handle this, as will be discussed in clause 9.
+
+Another trade-off is between **network energy saving and UE energy saving**. In most cases, network energy saving is decoupled from UE energy saving. However, trade-offs exist in some scenarios. For example, to save power for items of UE, the network performs substantial adaptation in the design of common signalling, and these adjustments usually increase the overheads on the network side. However, an Internet of Things terminal has a strict requirement on low power consumption, which exacerbates this contradiction. The terminal may selectively listen to a paging of a network for energy saving, but the network cannot arbitrarily reduce its paging density.
+
+The number of items of UE in a cell fluctuates. However, the network needs to implement flexible scaling of common signalling overheads to reduce the power consumption of the BSs in light load scenarios. The UE side needs to be aware of and compatible with the dynamic adjustment of the common signalling on the BS side to reduce the impact on processes such as initial UE access and cell handover and reselection.
+
+## 8 Energy saving technologies for 5G RAN
+
+5G will add many new functionalities to the RAN and will also deploy more resources in the form of carriers, bandwidth, transmit antennas and output power. This not only means increased capacity and capabilities of the network, by following the design principles in clause 7 there are also large opportunities for energy saving technologies.
+
+However, the complexity of the 5G network and the difficulty of operation and management will also increase. This also holds for the management and control of energy saving technologies, as other aspects such as coverage, interference, user QoS and so on also need to be considered when using the different energy saving technologies. It is difficult to use a fixed or simple algorithm to guarantee optimal performance. Therefore, AI needs to be introduced, and how to use AI technology to realize energy saving applied to the operation and management of wireless communication units becomes more and more important. Therefore, clause 9 will be dedicated to AI-based energy saving, while this clause will focus on the energy saving technologies themselves.
+
+### 8.1 Time-domain energy saving
+
+Time-domain energy saving utilizes symbols, timeslots or subframes where no valid information is transmitted for energy saving; this is carried out by shutdown of related components. Symbol power saving in LTE, sometimes referred to as cell discontinuous transmission (DTX) [b-Frenger], is a well-known example for this in which the PA is deactivated in symbols where no information is to be transmitted, as illustrated in Figure 3.
+
+
+
+Figure 3: Illustration of time-domain energy saving. The diagram shows a sequence of 12 rectangular blocks representing OFDM symbols. The 1st, 5th, 9th, and 13th symbols are colored orange, while the others are grey. Below the sequence, four brackets labeled 'PA off' indicate periods where the power amplifier is deactivated. These periods correspond to the gaps between the orange symbols, specifically covering the 2nd-4th, 6th-8th, 10th-12th, and 14th-16th symbols (assuming the sequence continues). The text 'L.1390(22)' is visible in the bottom right corner of the diagram area.
+
+**Figure 3 – Illustration of time-domain energy saving: During symbols with no information to transmit, the PA is deactivated**
+
+However, even an empty LTE carrier transmits the cell-specific reference signals (CRS) approximately every 0.2 ms, which means that only very short (2–3 OFDM symbols) component de-activations are possible. 5G has addressed this issue by drastically reducing the signal load in idle mode to allow for more time-domain energy saving. The most necessary control signals for access are still broadcast but many other signals are only transmitted on-demand from the accessing user
+
+devices. Furthermore, the periodicity of the necessary control signals can be configured between 5 ms and 160 ms. For a coverage-providing carrier the default periodicity is 20 ms [b-3GPP TS38.213]. This means that in idle mode a 5G carrier can have approximately 100 times longer silent periods than an LTE carrier (20 ms vs 0.2 ms) [b-Frenger], during which time-domain energy saving can be applied.
+
+Furthermore, also when the carriers are loaded, time-domain energy saving can be applied. Due to the bursty nature of traffic, empty symbols are common also in loaded traffic scenarios. It is also possible to create empty symbols, time slots and even subframes by smart scheduling decisions. Hence, time-domain energy saving is a very important energy saving technology that should be used in 5G.
+
+### 8.2 Spatial-domain energy saving
+
+In spatial-domain energy saving, a number of the RF channels are deactivated in low load scenarios [b-Skillermark] [b-Halbauer]; see Figure 4. This is sometimes referred to antenna or MIMO muting or RF channel shutdown. The idea is that the remaining capacity should be enough to serve the traffic, but coverage and data rates may be affected since some of the PAs and thereby the available output power is taken out of service. However, there are methods to compensate for this, e.g., by common signal power boosting.
+
+Since 5G in general, and massive MIMO in particular, uses more antennas and RF channels than previous generations, spatial-domain energy saving is an important energy saving technology that should be used in 5G.
+
+
+
+Figure 4: Illustration of spatial-domain energy saving. The diagram shows a transition from a fully active antenna array to a partially deactivated one. On the left, a 4x4 grid of 16 green circles (representing antenna elements) is shown above a yellow antenna icon. A red arrow points to the right, where the same 4x4 grid is shown, but only 8 green circles remain (in the first and third columns), while the other 8 circles are grey, indicating they are deactivated. The yellow antenna icon remains below the grid.
+
+**Figure 4 – Illustration of spatial-domain energy saving: During low load periods, a number of antenna elements and corresponding RF channels are deactivated**
+
+### 8.3 Frequency-domain energy saving
+
+Frequency-domain energy saving relates to reducing the available frequency bandwidth and thereby saving energy. There are two classes of frequency-domain energy saving:
+
+- 1) **Large-scale:** In this case an entire carrier is shutdown, and consequently it is sometimes referred to as carrier shutdown. Carriers corresponding to some frequency bands or frequencies are shut down, as illustrated in Figure 5. When these carriers are mapped to independent physical hardware components (e.g., a radio unit), corresponding components can be shut down and thereby save energy.
+- 2) **Small-scale:** Such as bandwidth shrinking and subcarrier shutdown. In this case only carrier specifications are adjusted. The entire carrier is still working, and component shutdown cannot be implemented. In this case, the specifications of certain processing units can only be adjusted to reduce power consumption, which means that the dynamic capability (the $\alpha$ parameter) is crucial for the achievable energy saving.
+
+
+
+Figure 5: Illustration of large-scale frequency-domain energy saving, carrier shutdown. The diagram shows two frequency bands on a horizontal axis labeled 'Freq'. On the left, two blue vertical bars represent active carriers. A red arrow points to the right, where one blue bar remains active and the other is a grey, inactive bar. Below the inactive bar is the text 'L.1390(22)'.
+
+**Figure 5 – Illustration of large-scale frequency-domain energy saving, carrier shutdown: One of the two carriers is shutdown, and the related radio unit is deactivated to save energy**
+
+With the roll-out of 5G on new frequency bands, in particular large-scale frequency-domain energy saving, such as carrier shutdown, will be an important energy saving technology that should be used. With low load in the network and overlapping network coverage, some carriers can be shut down to save energy. This can also be coordinated over different radio access technologies. Taking the overlapping network of NR and LTE as an example, we can consider NR is the capacity system and LTE the basic coverage system. If the NR traffic is low, the NR can be intelligently shut down and the traffic transferred to LTE at the same time. Once LTE service exceeds a certain threshold, the NR carrier is reactivated. In this way, the power consumption of the whole network changes with the traffic volume.
+
+### 8.4 Power-domain energy saving
+
+Power-domain energy saving relates to reducing or scaling down the PA output power by different means, thereby reducing the transmission power consumption. Due to an increased number of carriers, wider bandwidths and a higher number of transmit antennas, the transmit power requirement of 5G equipment is typically higher compared with previous generations of communication technologies. Unfortunately, this contradicts energy saving objectives, as a higher transmit power requirement typically implies a higher PA output power and thereby power consumption. Hence, it is recommended to pursue different methods to reduce PA output power, while still maintaining all network performance KPIs.
+
+One track that should be used is to improve the energy transmission efficiency. This can be done both with software and hardware. Beam optimization software can be used to optimize the link between the BS and the UE, thereby improving the beam pointing precision and reducing transmit energy waste, which also means that lower output power is required. Appendix I introduces this technology in more detail.
+
+In the hardware domain, an obvious way to improve energy transmission efficiency is to utilize the antenna domain and design antennas with higher antenna gain. By doing that, the output power from the power amplifier to the antenna can be lower, while utilizing the higher antenna gain to generate the desired radiated power (EIRP) from the antenna. The benefit is maintained coverage with lower equipment power consumption. Appendix II and Appendix III introduce two example technologies for realizing this: ultra-large antenna arrays and Luneberg lens antennas, respectively.
+
+## 9 AI-based energy saving for 5G RAN
+
+The research and application progress of artificial intelligence (AI) in the field of cellular networks is rapidly moving forward. It is believed that AI can be introduced into the network on three levels: network element intelligence, operation and management (O&M) intelligence (see e.g., [b-ITU-T M.3080]), and service intelligence, with the principles of being tiered, on-demand and phased. In this way, ubiquitous intelligence can be achieved.
+
+In this Recommendation, it is proposed to optimize and control the energy saving technologies introduced in clause 8 using AI technology. This results not only in a more efficient utilization of energy saving technologies and consequently more energy savings, but also a self-adaptive network reducing the human resources required for O&M.
+
+### 9.1 AI technology
+
+Artificial intelligence is the area of computer science focusing on creating machines that can engage in behaviours that humans consider intelligent. It combines computer science, physiology and philosophy and is a broad topic consisting of different fields, from machine vision to expert system.
+
+The element that the fields of AI have in common is the creation of machines that can "think". The ability to create intelligent machines has intrigued humans since ancient times, and with the advent of the computer and over 50 years of research into AI programming techniques, the dream of smart machines is becoming a reality. For more details, see [b-ITU-T L.Sup43].
+
+### 9.2 Energy saving based on AI
+
+Many MNOs are running 2G, 3G, 4G and 5G networks at the same time. The spatial and temporal distribution of cellular network traffic varies significantly, with obvious peaks and troughs. At the same time, basic functions applied to the entire cellular network are not site specific, resulting in unnecessary inefficiencies due to ignoring the traffic and neighbouring site patterns that varies from site to site, especially in a more complex network.
+
+By introducing AI and big data technology, a more precise energy saving strategy based on site specific traffic and other site-related conditions can be achieved. The AI-based RAN energy saving solution can forecast the traffic load of BSs based on historical traffic load, service type, site coverage and user behaviours. An energy saving strategy can automatically be configured based on co-coverage identification and configuration detection by AI. The suitable energy saving strategy combined with different energy saving functions (see clause 8), including an initial relative threshold to the scenario and executable energy saving time schedule, will be enabled for the sites that are expected to have energy saving effects. Meanwhile, the AI-based RAN energy saving solution can also ensure the balance between network power consumption and network performance based on sufficient model training.
+
+The basic functions of an AI-based RAN energy saving solution should include but not be limited to the following:
+
+- 1) **Scene identification:** Based on history traffic model analysis, the application scenario should be automatically identified, such as business district, residential areas, high-speed train, etc., and thus more suitable initial energy saving strategies will be selected.
+- 2) **Traffic forecast:** In most cases, the forecast matches well with the actual traffic, which means that energy saving can be enabled on far more occasions. The modelling is based on historical traffic data (physical resource block (PRB) utilization, RRC connected users, online users, throughput, etc.), special days or holidays, user behaviour, etc. and then time series algorithms will be applied for traffic load forecast.
+- 3) **Co-coverage identification:** To achieve an efficient energy saving strategy specific to a certain cell, the coverage of the cell and its neighbouring cells' coverage and traffic load all need to be taken into consideration. The reason is that any shutdown of a cell with direction of its users to neighbouring cell(s) has to rely on the good availability of the neighbouring cell(s) including coverage and capacity. Thus, co-coverage identification relying on operating parameters (site ID, longitude, latitude, antenna height and azimuth) and MR (measurement report) data (cell ID, RSRP (reference signal received power), SINR (signal to interference plus noise ratio), TA (timing advance)) is needed. Based on this information, the cell coverage performance can be calculated to identify the relationship between the co-coverage cells.
+- 4) **Online iteration and parameter optimization:** In order to improve the energy saving efficiency, online iteration and optimization of parameters can be used instead of the traditional ways which do not take site variations into consideration. In this way, a more precise energy saving strategy tailored to each site is achieved.
+
+### 9.3 Architecture of AI-based energy saving
+
+Figure 6 shows the overall architecture of an AI-based energy saving solution. On top is the intelligent application platform, where the AI algorithms are executed based on data from the underlying network management layer. The output from the AI algorithms are fed back to the network management layer and used for configuration of the BSs in the network element layer. This is adopted to achieve the maximum balance between the system performance and the energy saving effect, so as to achieve the network energy saving and consumption reduction.
+
+
+
+The diagram illustrates the overall architecture of a 5G intelligent energy saving solution, organized into three horizontal layers separated by dashed lines. The top layer, labeled 'Intelligent application platform' on the right, contains three horizontal boxes: 'Application scenario' (with sub-components 'Scenario identification', 'Predictive analysis', and 'Parameter optimization'), 'Model building' (with 'Reasoning training' and 'Model optimization'), and 'Data processing' (with 'Data cleaning', 'Data construction', and 'Data aggregation'). The middle layer, labeled 'Network management layer' on the right, contains two boxes: 'Data acquisition' and 'Configuration management'. The bottom layer, labeled 'Network element layer' on the right, contains two boxes: '4G base station eNB' and '5G base station gNB'. A vertical label 'L.1390(22)' is located at the bottom right of the diagram.
+
+Overall architecture of 5G intelligent energy saving solution diagram
+
+**Figure 6 – Overall architecture of 5G intelligent energy saving solution**
+
+By shutting down the time-, spatial- and frequency-domain resources that are not utilized and keeping network capacity adequate yet to a minimum, network energy consumption can be optimized in line with the network traffic load forecast. The AI-based energy saving solutions can take into account the different efficiency levels of frequency bands and factors in that the power efficiency of different resources can vary. By directing users from their less-power-efficient spectrum band(s) to one or more other bands that are more power-efficient, more radio resources can be shut down more often to lower network energy consumption. An example practice, also including service awareness, is given in Appendix IV.
+
+## Appendix I
+
+### Example of 5G power-domain energy saving practices – Beam optimization energy saving
+
+(This appendix does not form an integral part of this Recommendation.)
+
+With the development and deployment of 5G technology, the network coverage scenarios are gradually diversified. At the same time, large-scale MIMO antennas introduce more dimensional adjustable parameters, including horizontal beamwidth, vertical beamwidth, azimuth angle, down tilt angle, number of beam scans, etc. Therefore, the traditional manual beam adjustment method is no longer feasible. In order to achieve automatic adjustment and improve radiation efficiency, the beam is adjusted adaptively and flexibly to achieve beamforming, so as to achieve the best coverage effect and performance gain in various scenarios and to realize the dynamic coordination of antenna coverage area following user position, and finally achieve the goal of optimizing beam direction, aligning hotspot area and reducing energy consumption.
+
+Beam optimization is first used to distinguish cell coverage scenarios such as low-rise buildings, high-rise buildings, roads and squares through scene recognition technology. At the same time, the geographical area is divided into many location grids, and different scenes are calculated according to the threshold set by the algorithm. For example, the proportion of road scenes is equal to the total grid of road scenes/cell coverage. When the proportion of road scenes is higher than a certain threshold, this scene is considered to be a road scene. This is illustrated in Figure I.1 and Figure I.2.
+
+
+
+Figure I.1: A grid-based map showing the proportion of different scene types. The map is divided into a grid of cells, each containing a number (1, 4, 285, 284, 276, 290) and colored red, green, or yellow. The x-axis ranges from 731200 to 731600, and the y-axis ranges from 2.563600 to 2.564000. A title '460-00-12583877-02' is visible at the top.
+
+Figure I.1 – The proportion of scene in the grid
+
+
+
+Figure I.2: A road scene recognition and rendering image. It shows a complex network of roads and buildings in a stylized, color-coded format. Roads are highlighted in green and red, while buildings and other areas are in black and blue. The image is a dense, pixelated representation of a geographical area.
+
+Figure I.2 – Road scene recognition and rendering
+
+Based on historical MDT, PM data and big data machine learning algorithms, the time and space of user hotspot distribution is predicted, and after a high price reduction is performed on the parameter space of each cell to be optimized, the two indicators RSRP and SINR are evaluated to form a cost function and select the appropriate weight combination from the beam library according to the scene characteristics.
+
+In addition, considering that the 5G Massive MIMO antenna has more streams, the beam downlink can optimize each sub-beam to achieve accurate coverage for each item of UE, so the energy is more focused, and the anti-interference ability is stronger. In addition, the beam uplink receives gain through multiple antennas, so the user experience is better. The shaping of the sub-beams can effectively improve the spectrum efficiency and avoid excessive waste of resources, finally, achieving energy saving effects by beam optimization. This is illustrated in Figure I.3 and Figure I.4.
+
+
+
+Figure I.3: Beam optimization for every UE. This diagram shows a 5G base station on the left emitting multiple colored beams (blue, green, yellow) towards several user equipment (UE) icons on the right. A heatmap overlay on the right side shows signal strength or coverage areas, with colors ranging from green to red. A large brown arrow indicates the direction of the beams from the base station.
+
+**Figure I.3 – Beam optimization for every UE**
+
+
+
+Figure I.4: Sub-beam and UE distribution. This diagram illustrates a base station on the left with a grid of antennas, emitting four distinct sub-beams labeled UE0 (yellow), UE1 (orange), UE2 (orange), and UE3 (blue). These beams are directed towards four separate user equipment icons on the right, showing a one-to-one mapping between sub-beams and UEs.
+
+**Figure I.4 – Sub-beam and UE distribution**
+
+## Appendix II
+
+### Example of 5G power-domain energy saving practice – Ultra-large-scale antenna array with beam pattern optimization
+
+(This appendix does not form an integral part of this Recommendation.)
+
+For antenna array of AAU, the larger size of the antenna array, the narrower beam of the channel, thus, the more focused channel energy and the longer distance of the network coverage. With the introduction of an ultra-large-scale antenna array, the uplink and downlink coverage can be increased synchronously without increasing the transmission power. This can also be used for energy saving with maintained coverage; with the ultra-large-scale antenna array the output power from the power amplifier to the antenna can be lower, while utilizing the higher antenna gain to generate the desired radiated power from the antenna. This results in maintained coverage with lower equipment power consumption.
+
+One method to generate higher antenna gain is to use an ultra-large antenna array. This not only improves the antenna gain, the larger array also forms narrower beams which spread less interference, and consequently the network performance is also improved.
+
+A trial with such ultra-large-scale antenna arrays was deployed in Xiamen city, which doubled the size of the antenna array of the AAU (elements from 192 to 384, see Figure II.1) and used new materials and architectures in manufacture. It adopted adaptive beam optimization and intelligently adapts the user's wireless channel changes to improve the utilization efficiency of air-interface resources, and adopts high-resolution beam domain noise reduction to improve the efficiency of multiuser pairing. This enables the new AAU to achieve "accurate-alignment", to be "fast-following" and offer "good-pairing", which can greatly improve user experience and cell capacity.
+
+
+
+Figure II.1: Comparison of traditional AAU and new Architecture AAU. The diagram shows two antenna units. The traditional AAU on the left has dimensions of 699 mm in height and 395 mm in width, with a green beam pattern. The new Architecture AAU on the right has dimensions of 1500 mm in height and 400 mm in width, with a red beam pattern. An arrow points from the traditional AAU to the new AAU, indicating an upgrade. The label 'L.1390(22)' is visible in the bottom right corner of the image.
+
+**Figure II.1 – Comparison of traditional AAU and new Architecture AAU
+(number of antenna elements is from 192 to 384)**
+
+Test results show that compared with the traditional solution, the new AAU can increase the cell's uplink coverage and downlink coverage, and the average experience of edge users can be increased by 20%. If the coverage index of the cell edge remains unchanged, the BS can be configured with lower transmission power, thereby reducing the energy consumption of the BS. Compared with traditional AAU, the energy consumption can be reduced by about 30%.
+
+Therefore, the use of ultra-large-scale antenna arrays shows great potential to improve coverage and reduce energy consumption. Through the integration and innovation of new architectures and new algorithms, both network performance and energy saving can be achieved, helping MNOs to build better and greener 5G networks.
+
+## Appendix III
+
+### Example of a 5G power-domain energy saving practice – High gain antenna-lens antenna
+
+(This appendix does not form an integral part of this Recommendation.)
+
+With the continuous development of mobile communication networks, 4G/5G networks have basically achieved full network coverage; however, there are also many coverage problems that are difficult to solve, such as coverage of long and narrow scenes, 5G high-frequency bands and large penetration attenuation.
+
+As a new type of antenna using the principle of the Luneburg lens (Figure III.1), the function of the relationship between the refractive index $n$ and the radius of the lens antenna is:
+
+$$n = (2 - r/R)/2$$
+
+where $r$ is the radial distance from the centre of the sphere and $R$ is the radius of the sphere. When $r = R$ , $n = 1$ , and at the centre of the sphere ( $r = 0$ ), $n = 2$ .
+
+
+
+Figure III.1 – Principle of the Luneberg lens. The figure consists of two parts. The left part is a schematic diagram of a spherical lens antenna. It shows a circle representing the lens with radius R. A point S on the left edge is labeled 'Element'. A vertical y-axis and a horizontal x-axis pass through the center O. A dashed line represents a ray path from S to the right edge. A radial distance z(r) is indicated. The right part is a 3D visualization of the lens antenna's radiation pattern, showing a highly directional beam. A color scale from blue to red is shown, and a label 'Phi x' is present. The text 'L.1390(22)' is at the bottom right of the 3D plot.
+
+Figure III.1 – Principle of the Luneberg lens
+
+As a new type of antenna, the lens antenna has good beam convergence, can converge incident electromagnetic waves of a specific wavelength to a certain point on the spherical surface and can convert spherical or cylindrical waves into plane waves. Therefore, the lens antenna can effectively improve radiation efficiency and reduce energy consumption.
+
+The lens antenna has two main advantages as follows:
+
+- 1) Compared with the traditional plate antenna (Figure III.2), the lens antenna has a higher antenna conversion efficiency. Because the beam gain of the traditional plate antenna is formed by stacking elements, the internal feeding loss of the antenna is larger, and the input signal is attenuated more. The conversion efficiency of the traditional plate antenna is between 50% and 75%, while the feed line of the lens antenna is relatively simple, the signal attenuation is almost 0 and the conversion efficiency is above 90% on average. Therefore, the conversion efficiency of the lens antenna is much higher than that of the traditional antenna.
+
+
+
+Figure III.2: Comparison of a traditional plate antenna and a Luneberg lens antenna. The left side shows a traditional rectangular plate antenna with multiple elements. The right side shows a Luneberg lens antenna, which is a semi-circular lens with a flat back, labeled 'Lens' and 'Element'. The text 'VS' is between them, and 'L.1390(22)' is at the bottom right.
+
+**Figure III.2 – Traditional plate antenna vs Luneberg lens antenna**
+
+The experiments of the 5G network show that the remote radio units (RRUs) with the same output power are used to feed the traditional plate antenna and the lens antenna. The RSRP (field strength) of the lens antenna with a gain of 16.5dBi is higher than that of the plate antenna with a gain of 20dBi; under the same fringe field strength requirements, the usage of lens antennas can effectively reduce the power of BS equipment by more than 80%.
+
+- 2) Since the vertical beamwidth of the lens antenna is wider than that of ordinary antennas, it is more advantageous in the coverage of striped scenes. Therefore, the vertical half-power beamwidth of the lens antenna is between 12–30 degrees, so the lens antenna has a better coverage depth $D$ :
+
+$$D = H/\tan(\alpha - \theta/2)$$
+
+where $\alpha$ is the down tilt angle, $H$ is the antenna height, and $\theta/2$ is the vertical half-power angle.
+
+It can be seen from the above formula that under the conditions of fixed height and input power, the greater the value of $\theta$ , the longer the coverage distance, which can effectively reduce the radiation power and reduce the energy consumption of the equipment (see also Figure III.3).
+
+
+
+Figure III.3: Illustration of antenna coverage. A diagram showing a vertical line of height H representing the antenna. A horizontal line of length D represents the ground. A line from the top of the antenna to the end of the ground line represents the coverage edge. The angle between the vertical line and this edge line is labeled alpha (down tilt angle). Another angle, theta/2 (vertical half-power angle), is shown between the vertical line and a line to the middle of the ground line. The text 'L.1390(22)' is at the bottom right.
+
+**Figure III.3 – Illustration of antenna coverage**
+
+Based on the above characteristics, the lens antenna has a good coverage characteristic in high-speed railway scenes. Due to problems such as large insertion loss and Doppler effect in high-speed railway, the distance between stations on the existing network has been becoming closer and closer in recent years. For operators, the energy consumption of the equipment on the BS is becoming higher and higher, and the investment cost is also increasing.
+
+In an actual case, a high-speed railway section with a total mileage of about 32 km is covered by a high-speed railway dedicated network. The average distance between the BSs is more than 1.3 kilometres, and the number of BSs is 25. The coverage effect is relatively poor when using traditional plate antennas (Figure III.4). After testing, the average field strength (RSRP) is only below $-100$ dBm, and the average SINR is only 6.56. The user experience is poor in practice.
+
+
+
+Figure III.4: Trial results for traditional plate antenna. A map showing a winding path of colored dots representing signal strength (RSRP) measurements. The legend on the right indicates RSRP levels from x ≤ -110 dBm (red) to x > -50 dBm (green). The path shows a mix of colors, indicating varying signal strength. A scale bar indicates 20 km. Coordinates at the bottom left are Lon: 101.5919194, Lat: 38.7870766. The label L.1390(22) is in the bottom right.
+
+**Figure III.4 – Trial results for traditional plate antenna**
+
+In order to improve the coverage level, local operators need to double the number of sites to 50 by using traditional antennas.
+
+Using lens antennas to replace the original traditional plate antennas, the coverage has been greatly improved while keeping the site and transmitting power unchanged (Figure III.5). Test shows that the coverage distance of the lens antenna is 30-50% higher than that of the traditional antenna, and the coverage distance of the single antenna is increased by more than 300 metres. The reception level of edge users can be increased by 5 to 6 dBm, and the distance between the BSs and the edge coverage indicators remain unchanged. Under these circumstances, the BS can be configured with a lower transmission power, thereby reducing the energy consumption of the BS, which is more than half of the energy consumption compared with traditional antennas.
+
+
+
+Figure III.5: Trial results for lens antenna. A map showing a winding path of colored dots representing signal strength (RSRP) measurements. The legend on the right indicates RSRP levels from x ≤ -20 dBm (red) to x > 50 dBm (green). The path shows a mix of colors, indicating varying signal strength. A scale bar indicates 20 km. Coordinates at the bottom left are Lon: 101.4260488, Lat: 38.1354281. The label L.1390(22) is in the bottom right.
+
+**Figure III.5 – Trial results for lens antenna**
+
+According to Table III.1, the coverage effect of the lens antenna on the high-speed rail has been greatly improved while a large amount of construction resources has been saved.
+
+In summary, as a new type of antenna that has emerged in recent years, the lens antenna has brought a new direction to the development of mobile communication networks. It can effectively improve the coverage efficiency and reduce the power consumption with its excellent radiation characteristics and good beam characteristics.
+
+**Table III.1 – Summary of trial results**
+
+| Comparison test | Average RSRP | Average SINR | LTE coverage ratio (RSRP > -110 and SINR > -3) |
+|------------------------|---------------------|---------------------|-------------------------------------------------------------|
+| Traditional antenna | -101.63 dBm | 6.56 | 79.19% |
+| Lens antenna | -94.33 dBm | 11.75 | 99.25% |
+
+## Appendix IV
+
+### Example of energy saving practice based on AI – Service awareness energy saving for 4G/5G coordination
+
+(This appendix does not form an integral part of this Recommendation.)
+
+AI-driven-energy-saving solutions with traffic forecast improve the energy saving efficiency of basic functions. H in most multimode and multifrequency cellular networks, it still has some limitation that service efficiency varies from mode to mode, and/or band to band. And if all services/users are concentrated in part of the network/band, more energy consumption could be saved after idle network/band shut down or deep sleep.
+
+AI-driven service awareness in the 5G network should also be taken into consideration, which exploits the differences in energy efficiency of different types of services to deliver certain services to the most energy-efficient network, helping achieve the most efficient energy usage without impact on user experience [b-GSMA-2].
+
+The solution involves providing automation capabilities for the service management layer and resource management layer. Based on network-level AI-based intelligent energy saving policy management and site energy saving scheduling control, the mobile network energy saving solution implements network scene adaptation, one site one policy and multinetwork collaboration for intelligent BS energy saving management (Figure IV.1). This maximizes network energy saving benefits while ensuring stable network performance and achieves the optimal balance between energy consumption and KPIs.
+
+
+
+Figure IV.1: Powered by AI, network energy saving accurate deployment. The diagram illustrates an AI-driven energy saving architecture. At the top, an 'AI engine' cloud is connected to a 'PowerPilot platform' (represented by a server rack icon). The AI engine provides 'Model training' and receives 'Effect feedback' from the platform. The PowerPilot platform is connected to four base stations (represented by antenna icons) via 'Strategy coordination' and 'Performance reporting' arrows. To the right, two boxes detail the AI components: 'Platform with AI' includes 'Machine learning based traffic forecast' (shown as a 3D bar chart) and 'Traffic-aware spectrum utilization' (shown as a heatmap). 'Site with AI' includes 'Sub-cell modelling' (shown as a network graph), 'Service awareness' (shown as a bar chart), and 'Comprehensive shutdowns' (shown as a radio tower with a sleep symbol). The diagram is labeled 'L.1390(22)' at the bottom right.
+
+**Figure IV.1 – Powered by AI, network energy saving accurate deployment**
+
+#### Cell-specific initial strategy
+
+The initial energy saving strategy can automatically be configured based on co-coverage identification and configuration identification by AI technology. The suitable energy saving strategy combined with different energy saving technologies, including an initial parameter setting to the scenario and executable energy saving time schedule, will be enabled for the sites that are expected to have energy saving effects.
+
+- Idle or low traffic period based on historical traffic analysis;
+
+- Energy saving threshold based on network traffic load;
+- Energy saving activation time based on threshold;
+- Energy saving function combination.
+
+#### Traffic load forecast
+
+The intra-week sub-sequence split prediction method – in which each of the seven days in a week is put into the series of its corresponding days in all the weeks under consideration – is combined with cell types, holiday factors and forecast of network traffic load. After putting all the algorithm candidates (linear regressive, ARIMA (auto-regressive integrated moving average model) and LSTM (long short-term memory), second-order exponential smoothing, etc.) into tests, the one with the best results is selected.
+
+The results of commercial application cases showed that the prediction accuracy exceeds up to 90% for uplink/downlink PRB utilization and RRC connected users.
+
+#### Service awareness
+
+Based on energy saving functions and AI-based traffic load prediction, a pilot practice solution to introduce AI-powered service awareness energy saving is presented here (Figure IV.2). By identifying service types and their energy efficiency differences, service requirements can be evaluated in real time and support the service with networks of higher energy efficiency to maximize energy efficiency in the entire network. To improve the network energy efficiency based on user redistribution, there are three main steps: target network/band selection, suitable user selection and consequent user direction. Service efficiency varies from network to network and/or band to band; the most energy-efficient network/band will be selected as a target and the most suitable users will be selected. Also, the energy efficiency pattern may change after user direction, leading a new round of optimization. Thus the three steps together form a closed loop.
+
+
+
+The diagram illustrates a three-step process for service awareness energy saving:
+
+- Network/band selection:** This step shows two network configurations. The top configuration shows Network 1 as the source, with icons for 'payment' and 'IP phone'. The bottom configuration shows Network 2 as the target, with icons for 'video', 'payment', and 'video on demand'. Below the diagrams, the condition $EE_{\text{network2}} > EE_{\text{network1}}$ is indicated.
+- User/service selection:** This step shows the selection criteria for users and services. It is divided into three sections:
+ - By user priority:** Shows icons for two users.
+ - By service type:** Shows a grid of service types: messaging, payment, video, video on demand, social networking, and IP phone.
+ - By throughput:** Shows a bar chart with an upward arrow.
+- Real-time service steering:** This step shows the result of the selection process. Network 1 is shown with a red 'off' button, indicating it is shut down. Network 2 is shown as the target, with icons for 'video', 'payment', 'messaging', 'IP phone', and 'video on demand'.
+
+Figure IV.2 – Service awareness energy saving. The diagram illustrates a three-step process for energy saving: Network/band selection, User/service selection, and Real-time service steering. Step 1 shows Network 1 as source and Network 2 as target, with EE\_network2 > EE\_network1. Step 2 shows selection by user priority, service type, and throughput. Step 3 shows Network 1 shut down and Network 2 as target.
+
+Figure IV.2 – Service awareness energy saving
+
+#### Online iteration and optimization of the threshold
+
+In order to improve the energy saving efficiency, online iteration and parameter optimization can be used instead of the traditional ways; it does not take site variations into consideration and results in safe but inefficiency energy saving settings.
+
+A clustering algorithm is used to find the optimal energy saving parameter settings with the best efficiency and shortest time. In any case, when the KPI baseline is compromised, the parameter settings can be rolled back.
+
+#### Application and performance
+
+The solution was trialled in a commercial network in Chengdu city. The results with the Chengdu network show that over 35% of the network energy consumption of 4G/5G can be reduced without impact on the network performance or user experience.
+
+This commercial trial in Chengdu 4G/5G network involves three phases. With only the basic energy saving function, about 9.3 kWh energy is saved daily per site; when the AI-driven traffic forecast is enabled simultaneously, approximately 12.2 kWh energy is saved daily per site. After the AI-driven service pilot is enabled, up to 13.7 kWh energy can be saved daily per site (Figure IV.3). During the trial, there was less impact to network performance, both in the 4G network and in the 5G network (Figure IV.4).
+
+
+
+| Configuration | Energy Saving (kWh/site) |
+|------------------|--------------------------|
+| Basic functions | 9.3 |
+| Traffic forecast | 12.2 |
+| Service pilot | 13.7 |
+
+L.1390(22)
+
+Bar chart titled 'ENERGY SAVING (KWH/SITE)' showing energy savings for three configurations: Basic functions (9.3 kWh), Traffic forecast (12.2 kWh), and Service pilot (13.7 kWh).
+
+Figure IV.3 – Energy saving per site daily (kWh)
+
+
+
+The figure displays six performance metrics over a period from 2022-07-12 to 2022-11-08. The top-left chart shows 'RRC Connected User (Avg.)' as a line graph fluctuating between 20,000 and 35,000. The top-middle chart shows 'SN Addition Success Rate' as a line graph stable around 100%. The top-right chart shows 'Downlink Throughput (Mbps)' as a bar chart with values mostly between 25,000 and 40,000. The bottom-left chart shows 'RRC Success Rate' as a line graph stable around 99.9%. The bottom-middle chart shows 'Downlink Throughput (GByte)' as a bar chart with values mostly between 800,000 and 1,200,000. The bottom-right chart shows 'Downlink PRB Utilization' as a line graph fluctuating between 15% and 25%.
+
+Six line and bar charts showing network performance metrics over time: RRC Connected User (Avg.), SN Addition Success Rate, Downlink Throughput (Mbps), RRC Success Rate, Downlink Throughput (GByte), and Downlink PRB Utilization.
+
+Figure IV.4 – Network performance
+
+It is estimated that more than 5 million kilowatt-hours will be saved annually per thousand BSs and at least 2500 tonnes of carbon emissions will be reduced if this solution is deployed in the whole 4G/5G network in Chengdu.
+
+According to typical network configuration calculations, the energy saved by the solution is twice as much as that of the conventional AI-based energy saving solutions, and it can save up to 20% of energy in a multimode network, thereby effectively reducing the operational expenditure.
+
+## Bibliography
+
+- [b-ITU-T L.1470] Recommendation ITU-T L.1470 (2020), *Greenhouse gas emissions trajectories for the information and communication technology sector compatible with the UNFCCC Paris Agreement*.
+- [b-ITU-T L.Sup43] Supplement ITU-T L.Sup43 (2021), *Smart energy saving of 5G base stations: Traffic forecasting and strategy optimization of 5G wireless network energy consumption based on artificial intelligence and other emerging technologies*.
+- [b-ITU-T M.3080] Recommendation ITU-T M.3080 (2021), *Framework of artificial intelligence enhanced telecom operation and management (AITOM)*.
+- [b-3GPP TS38.213] 3GPP TSG RAN TS 38.213 (2019), *NR; Physical layer procedures for control (Release 16)*, v16.0.0.
+
+- [b-Auer] Auer, G., Giannini V., Desset, C., Godor, I., Skillermark, P., Olsson, M., Imran, M.A., Sabella, D., Gonzalez, M.J., Blume, O., and Fehske, A., (2011), *How Much Energy is Needed to Run a Wireless Network?* IEEE Wireless Communications, Vol. 18, No. 5, pp. 40–49
+
+- [b-Debaillie] Debaillie, B., Desset, C., Louagie, F., (2015), *A Flexible and Future-Proof Power Model for Cellular Base Stations*, IEEE 81st Vehicular Technology Conference (VTC Spring), 2015.
+- [b-Frenger] Frenger, P., Moberg, P., Malmodin, J., Jading, Y., and Godor, I., (2011), *Reducing Energy Consumption in LTE with Cell DTX*, IEEE 73rd Vehicular Technology Conference (VTC Spring), 2011.
+
+- [b-Frenger] Frenger, P., and Tano, R., (2019), *More Capacity and Less Power: How 5G NR can Reduce Network Energy Consumption*, IEEE 89th Vehicular Technology Conference (VTC Spring), 2019.
+
+- [b-GeSI] Global e-Sustainability Initiative (2015), *#Smarter 2030: ICT Solutions for the 21st Century Challenges*. [https://smarter2030.gesi.org/downloads/Full\\_report.pdf](https://smarter2030.gesi.org/downloads/Full_report.pdf)
+- [b-GSMA-1] GSMA (2019), *The enablement effect: The impact of mobile communications technologies on carbon emission reductions*.
+
+- [b-GSMA-2] GSMA (2020), *5G energy efficiencies: green is the new black*,
+
+- [b-Halbauer] Halbauer, H., Weber, A., Wieagner, D., and Wild, T., (2018), *Energy efficient massive MIMO array configurations*, 2018 IEEE Globecom Workshops.
+- [b-Holtkamp] Holtkamp, H., Auer, G., Giannini V., and Hass, H., (2013), *A parameterized base station power model*, IEEE Communications Letters, Vol. 17, No. 11.
+
+- [b-Skillermark] Skillermark, P., and Frenger, P., (2012), *Enhancing energy efficiency in LTE with antenna muting*, IEEE 75th Vehicular Technology Conference (VTC Spring).
+
+[b-Viktor]
+
+Mayer-Schönberger, V. and Cukier, K. (2013), *Big data: a revolution that will transform how we live, work and think*, Houghton Mifflin Harcourt, New York.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1391-202401-I_PDF-E/raw.md b/marked/L/T-REC-L.1391-202401-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..619d200ca76f2588586e89e94bc7b4372381af28
--- /dev/null
+++ b/marked/L/T-REC-L.1391-202401-I_PDF-E/raw.md
@@ -0,0 +1,595 @@
+
+
+# Recommendation **ITU-T L.1391 (01/2024)**
+
+SERIES L: Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant
+
+Energy efficiency, smart energy and green data centres
+
+---
+
+## **Specification of IMT-2020 network sharing and co-construction adapting to climate change mitigation**
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue circular emblem with a stylized globe and the letters 'ITU' in white.
+
+ITU logo
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+### **Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant**
+
+| | |
+|---------------------------------------------------------------|----------------------|
+| OPTICAL FIBRE CABLES | L.100-L.199 |
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+| OPTICAL INFRASTRUCTURES | L.200-L.299 |
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+| MAINTENANCE AND OPERATION | L.300-L.399 |
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000-L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200-L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300-L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400-L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500-L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600-L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700-L.1799 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T L.1391
+
+## Specification of IMT-2020 network sharing and co-construction adapting to climate change mitigation
+
+## Summary
+
+Recommendation ITU-T L.1391 specifies IMT-2020 (also known as 5G) network sharing and co-construction (NSCC) and their contribution to climate change mitigation, identifies their key technologies and specifies how to assess NSCC in their adaptation to climate change. Recommendation ITU-T L.1391 also addresses the cost-benefit analysis and best practice for IMT-2020 NSCC.
+
+Mobile network operators around the world are facing unprecedented difficulties in IMT-2020 deployment. Restricted by expensive spectrum resources, the need for high investment and high energy consumption of IMT-2020, the profit gap between operators and equipment manufacturers is growing, and a large number of problems related to business increment with no increase in revenue are arising. Methods of reduction in the cost of network construction and operation, adaptation to climate change mitigation and enablement of the rapid benefits of IMT-2020, especially in underdeveloped communications regions, present major challenges to the global industry and operators.
+
+## History \*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T L.1391 | 2024-01-13 | 5 | 11.1002/1000/15768 |
+
+### Keywords
+
+5G, climate change mitigation, co-construction, network sharing, RAN.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2024
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+###### Page
+
+| | | |
+|-----|----------------------------------------------------------------------------------------------------------------|----|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| 3.1 | Terms defined elsewhere ..... | 1 |
+| 3.2 | Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | Challenges of IMT-2020 network development..... | 3 |
+| 7 | Benefit of IMT-2020 network sharing and co-construction ..... | 4 |
+| 8 | Classification of network sharing and co-construction ..... | 5 |
+| 9 | Key technologies of IMT-2020 sharing and co-construction ..... | 5 |
+| 9.1 | Standard evolution of mobile network sharing and co-construction..... | 5 |
+| 9.2 | Key technologies for IMT-2020 network sharing..... | 5 |
+| 9.3 | IMT-2020 standalone international roaming under core network sharing ..... | 7 |
+| 9.4 | Planning and construction ..... | 7 |
+| 9.5 | Regulation and accounting or settlement ..... | 8 |
+| 9.6 | Operation and optimization ..... | 8 |
+| 10 | Environmental impact assessment of network sharing and co-construction ..... | 8 |
+| 11 | The contribution of IMT-2020 network sharing and co-construction to climate change mitigation..... | 9 |
+| 12 | Prospect of global mobile communication network sharing and co-construction..... | 11 |
+| | Appendix I – The practice of IMT-2020 network sharing and co-construction in China ..... | 12 |
+| I.1 | Global best practice of IMT-2020 network sharing and co-construction in China..... | 12 |
+| I.2 | Calculation of carbon-reduction by network sharing and co-construction in China Telecom and China Unicom ..... | 13 |
+| | Bibliography..... | 16 |
+
+# Introduction
+
+IMT-2020 (also known as 5G) is the most advanced cellular technology in commercial deployment of our era. While IMT-2020 offers much faster speed, massive connections and much lower latency, and has the potential to enable a much bigger variety of new applications for both people's lives and vertical industries, it does increase the energy consumption of mobile networks.
+
+More importantly, sustainability has risen to the top of the agenda for many industries, including telecommunications. Mobile network operators (MNOs) need to rethink the usage of energy and its impact on the environment, and this will have a profound effect on the way they plan and deploy next generation networks. Thus, collaborative network deployment among devices, sites, networks and even MNOs will become an inevitable trend.
+
+IMT-2020 network sharing and co-construction can effectively improve utilization efficiency of scarce spectrum resources and rapidly establish advanced mobile networks, thus circumventing the aforementioned problems. Via the quick construction of IMT-2020 full coverage networks from cities to counties, towns, and rural areas to realize universal IMT-2020 services and narrow digital gaps, this approach helps more people shake off poverty, pushing forward the UN 2030 agenda for sustainable development goals [b-UN SDG].
+
+# Recommendation ITU-T L.1391
+
+## Specification of IMT-2020 network sharing and co-construction adapting to climate change mitigation
+
+# 1 Scope
+
+This Recommendation specifies IMT-2020 (also known as fifth generation (5G)) network sharing and co-construction (NSCC) and their contribution to climate change mitigation, identifies their key technologies and specifies how to assess NSCC in their adaptation to climate change. This Recommendation also addresses the cost-benefit analysis and best practice for IMT-2020 NSCC.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T F.743.15] Recommendation ITU-T F.743.15 (2022), *Requirements for multi-operator core network enabled multimedia services*.
+- [ITU-T L.1210] Recommendation ITU-T L.1210 (2019), *Sustainable power-feeding solutions for 5G networks*.
+- [ITU-T L.1410] Recommendation ITU-T L.1410 (2014), *Methodology for environmental life cycle assessments of information and communication technology goods, networks and services*.
+- [ITU-T L.1430] Recommendation ITU-T L.1430 (2013), *Methodology for assessment of the environmental impact of information and communication technology greenhouse gas and energy projects*.
+- [ETSI ES 203 700] ETSI Standard ETSI ES 203 700 V.1.1.1 (2021), *Environmental engineering (EE); Sustainable power-feeding solutions for 5G network*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 carbon dioxide equivalent; CO2e ** [b-ISO 14064-1]: Unit for comparing the radiative forcing of a GHG to that of carbon dioxide.
+
+NOTE – The carbon dioxide equivalent is calculated using the mass of a given GHG multiplied by its global warming potential.
+
+**3.1.2 emission factor** [ITU-T L.1430]: A factor linking GHG emissions to a level of activity or a certain quantity of inputs, products or services (e.g., tonnes of fuel consumed or units of a product).
+
+NOTE – An electricity emission factor is commonly expressed as tonnes of CO2e per MWh. For example, an electricity emission factor of 1.3 means 1.3 t CO2e is emitted by consuming 1 MWh of electricity.
+
+**3.1.3 environmental impact** [ITU-T L.1410]: Impact including positive and negative aspects on the environment.
+
+**3.1.4 greenhouse gas; GHG** [b-ISO 14064-1]: Gaseous constituent of the atmosphere, both natural and anthropogenic, that absorbs and emits radiation at specific wavelengths within the spectrum of infrared radiation emitted by the Earth's surface, the atmosphere and clouds.
+
+NOTE 1 – For a list of GHGs, see the latest Intergovernmental Panel on Climate Change (IPCC) Assessment Report.
+
+NOTE 2 – Water vapour and ozone are anthropogenic as well as natural GHGs, but are not included as recognized GHGs due to difficulties, in most cases, in isolating the human-induced component of global warming attributable to their presence in the atmosphere.
+
+NOTE 3 – GHGs include carbon dioxide (CO2 ), methane (CH4 ), nitrous oxide (N2 O), hydrofluorocarbons (HFCs), perfluorocarbons (PFCs) and sulfur hexafluoride (SF6 ).
+
+**3.1.5 greenhouse gas emission; GHG emission** [b-ISO 14064-1]: Release of a GHG into the atmosphere.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 environmental impact assessment:** A process of evaluating the positive and negative environmental impacts of a proposed project or development.
+
+**3.2.2 network infrastructure:** All the active equipment and passive items needed to realize a network.
+
+NOTE 1 – Examples of active equipment are radio access network elements, like antennae, base transceiver stations and radio network controllers.
+
+NOTE 2 – Examples of passive elements of network infrastructure can be: masts; containers; towers; power supply; and air-conditioning equipment.
+
+**3.2.3 network sharing and co-construction:** A collaborative approach in which multiple individuals or organizations come together to jointly build and share network infrastructure or resources.
+
+NOTE 1 – Network sharing and co-construction involve active participation and contribution of all stakeholders to create and maintain the network, with the aim of achieving common goals and benefiting from shared resources and expertise.
+
+NOTE 2 – The sharing concept is often applied in areas such as telecommunications, transportation, and information technology, where the pooling of resources and knowledge can lead to more efficient and cost-effective solutions.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|------------------------------------------------|
+| 4G | fourth Generation |
+| 5G | fifth Generation |
+| 6G | sixth Generation |
+| AI | Artificial Intelligence |
+| CA | Carrier Aggregation |
+| CAPEX | Capital Expenditure |
+| DSS | Dynamic Spectrum Sharing |
+| EF | Emission Factor |
+| EIA | Environmental Impact Assessment |
+| FAST | Fusion-Assisting Super Time division duplexing |
+
+| | |
+|-----------|----------------------------------------------|
+| HPLMN | Home Public Land Mobile Network |
+| ID | Identifier |
+| IMT-2020 | International Mobile Telecommunications-2020 |
+| IMT-2020C | IMT-2020 Core |
+| MNO | Mobile Network Operator |
+| MOCN | Multi-Operator Core Network |
+| NR | New Radio |
+| NSA | Non-Standalone |
+| NSCC | Network Sharing and Co-Construction |
+| RAN | Radio Access Network |
+| RAT | Radio Access Technology |
+| RB | Resource Block |
+| SA | Standalone |
+| SRS | Sounding Reference Signal |
+| SUL | Super Uplink |
+| TDD | Time Division Duplexing |
+| TTI | Transmission Time Interval |
+
+# 5 Conventions
+
+None.
+
+# 6 Challenges of IMT-2020 network development
+
+Over the past few decades, mobile communications have experienced a huge development from first generation to IMT-2020. Mobile communication networks update every 10 years, which constantly brings breakthroughs in mobile communication capabilities. Every intergenerational leap and technological progress have greatly promoted industrial upgrade, as well as economic and social development, and have changed the way we live and work like never before. From analogue to digital communications, from voice to data services, the traffic throughput has increased hundreds of times, and mobile communication networks have created a prosperous Internet economy.
+
+As a new generation of mobile communication network, IMT-2020 not only solves the ultimate service experience that provides users with more immersive and extreme business experiences, such as augmented reality, virtual reality and ultra-high-definition video, but also solves the problem of communication between people and things, things and things, and meets the application needs of vertical industries such as mobile medical, Internet of vehicles, smart home, industrial control and environmental monitoring. With the rapid infiltration of IMT-2020 network into all walks of, IMT-2020 infrastructure construction has become the key to support digitalization and networking, as well as intelligent transformation of the economy and society.
+
+At the same time, the development of IMT-2020 networks for global operators is facing unprecedented difficulties and challenge, such as insufficient coverage, large investment in construction difficulties and high operating expenses. As of 2022, the global use of mobile services reached 5.3 billion, accounting for 67% of the world's total population, the proportion of IMT-2020 connections in the total number of connections is estimated to increase from 8% in 2021 to 25% in 2025 [b-GSMA 5G], it is expected that the number of IMT-2020 connections will account for one
+
+quarter of the total number of mobile connections in 2025; however, there is still no mobile communication signal coverage in underdeveloped regions and countries in the world. The main problem and challenge is how to enable billions of people in underdeveloped regions, e.g., in Africa, Latin America, the Middle East and West Asia, to enjoy mobile communications and experience the convenient life made possible by IMT-2020. Mobile communication signal coverage needs to be improved in these areas by the global communications industry and universal economic and social development programmes.
+
+Operator revenue will increase from \$1.08 trillion in 2021 to \$1.16 trillion in 2025, with operator capital expenditure (CAPEX) expected to reach \$620 billion from 2022 to 2025, of which 85% will be spent on IMT-2020 development [b-GSMA 5G]. In addition to the purchase of expensive wireless spectrum, due to the use of higher frequency bands and larger bandwidth, the site density of IMT-2020 base stations is at least three times those of the fourth generation (4G). The power consumption and construction cost of a single station are each about three times that of one of 4G, which makes IMT-2020 construction and operation and maintenance (O&M) costs rise significantly, while the site selection of new IMT-2020 base stations is difficult, and the greater demand for transmission networks with large bandwidth will make the overall investment in IMT-2020 more than four times that of 4G. In addition, common problems faced by global operators that urgently need to be solved include methods for: reduction in "scissors difference" profit between operators and equipment manufacturers; modification of the "increment without income increase" situation of operators; and reduction in IMT-2020 network construction and operating costs.
+
+# **7 Benefit of IMT-2020 network sharing and co-construction**
+
+From the current stage, implementation of sharing and co-construction in IMT-2020 is the most effective way to solve the problems mentioned in clause 6; such an approach cannot only reduce network-duplicated investment, but also accelerate the construction of IMT-2020 networks, leading to fast introduction of IMT-2020 services.
+
+From the perspective of investment, sharing and co-construction allow decreases, effectively reducing CAPEX in the process of IMT-2020 network construction. The higher network performance of IMT-2020 is associated with high investment costs, and it is difficult to achieve large-scale IMT-2020 network coverage in a short period of time by relying on the strength of a single operator. Through co-construction and sharing, existing network resources, for example, of two operators are coordinated to provide better network performance and achieve the effect of $1 + 1 > 2$ , which will greatly reduce repeated investment and construction of IMT-2020 networks.
+
+From the perspective of high-quality development requirements, sharing and co-construction are additive. Sharing and co-construction is conducive to combining the operator's own advantages with those of high-quality resources of all parties and exerting maximum efficiency.
+
+From the perspective of meeting the needs of users, sharing and co-construction should ensure that there is improvement in coverage and quality of IMT-2020 services. With the continuous development of the digital economy, industry and consumers are full of expectations of IMT-2020, but there is a gradual process of coverage, application and IMT-2020 network service nationwide. Through network co-construction and sharing, respective users of each party will use IMT-2020 services for a shorter period of time; the significant reduction in infrastructure construction expenditure will also help to reduce the level of IMT-2020 tariffs and to further promote speed-up with cost reduction. As the IMT-2020 service demonstration effect becomes more prominent, and 4G users continue to migrate to IMT-2020 networks, development will be promoted of IMT-2020 networks that are faster and better, and stable and high-quality IMT-2020 services realized for users.
+
+Sharing and co-construction can effectively reduce carbon emissions of base stations and thereby significantly increases social and economic benefits. IMT-2020 network sharing has proportionately decreased the number of devices deployed in the network, improved the utilization rate of equipment,
+
+and provided more services without increasing energy consumption. This therefore effectively reduces network power consumption, promotes green innovation and development, and promotes carbon peaking and carbon neutrality in a much faster manner.
+
+# **8 Classification of network sharing and co-construction**
+
+From the perspective of operation and management, there are two modes of sharing and co-construction. One is where operators build their own networks and share network resources through commercial agreements. The other is where operators set up a joint venture company for independent operation, especially one that is responsible for wireless network construction or maintenance.
+
+From the perspective of shared network resources, network sharing is divided into passive and active types. Passive sharing refers to the sharing of physical infrastructure, excluding active devices. Sharing part or all of the active equipment of the radio access network, including access network sharing, gateway core network and core network roaming, is referred to as active.
+
+Passive sharing is quite mature, while active sharing requires closer coordination between operators, making technical solutions more complicated. Therefore, this guideline mainly analyses active sharing.
+
+# **9 Key technologies of IMT-2020 sharing and co-construction**
+
+## **9.1 Standard evolution of mobile network sharing and co-construction**
+
+The evolution of mobile NSCC can be related to the work done by the 3rd Generation Partnership Project (3GPP) [b-3GPP TS 23.251] [b-3GPP TS 23.501] [b-3GPP TS 29.573] [b-3GPP TS 37.471] [b-3GPP TS 37.472] [b-3GPP TS 37.473]. IMT-2020 multi-operator core network (MOCN) radio access network sharing has been supported since 3GPP Release 15 [b-3GPP-TR 21.915], which standardized radio access network sharing in terms of network architecture, air interface, next generation interface and Xn interface protocol. The operator-level information object class adaptation to multi-cell identifier (ID) scenario was added in Release 17, and further research on sharing and co-construction management architecture is being carried out in Release 18 to specify better O&M management. [ITU-T F.743.15] specifies the requirements for MOCN-enabled multimedia services, i.e., using network-sharing capabilities to improve the quality of conventional multimedia services.
+
+## **9.2 Key technologies for IMT-2020 network sharing**
+
+#### **9.2.1 Radio access network sharing**
+
+The architecture of sharing of radio access networks (RANs) shall allow different core network operators to connect to them, including two kinds of sharing mode, MOCN with shared carrier and multi-operator RAN network (MORAN) with dedicated carrier.
+
+In the non-standalone (NSA) phase, the core network is deployed separately by operators, while the IMT-2020 new radio (NR) carrier is shared and 4G anchor carrier is shared as required, resulting in relatively complicated architecture. There are two modes of anchor cell: two dedicated anchor cells or one shared anchor cell.
+
+During the promotion phase from NSA to standalone (SA), the evolution path from NSA mode to NSA/SA dual mode and then to SA mode is generally recommended.
+
+In the SA phase, only IMT-2020 node B shall be connected to both IMT-2020 core (IMT-2020C) networks. Decoupled from the 4G network, no anchor cell solution is needed. With standard processing of 4G and IMT-2020 mobility management, both 4G and IMT-2020 user experience can be guaranteed.
+
+#### 9.2.2 Inter-network roaming for IMT-2020
+
+In the IMT-2020 inter-network roaming scenario, the sharing base station only connects to the core network of the main operator. The core network for a home public land mobile network (HPLMN) and visited public land mobile network shall be connected when user service flow can pass both core networks. The bearer networks shall also be connected to each other.
+
+In the NSA phase, only IMT-2020 NSA users are allowed to roam while other subscribers will only connect to the home network through a 4G evolved packet core. The management of users, billing and strategy control are separated in both core networks. The IMT-2020 network is constructed by the HPLMN with geographic separation.
+
+In the SA phase, with a new IMT-2020C deployed and connected, only SA users are allowed to roam. All 4G users whenever roaming will fall back to access the home network. SA users of the secondary operator can access the IMT-2020 network with a new public land mobile network.
+
+#### 9.2.3 Spectrum sharing
+
+Convenient and fast deployment has been the main focus of operators from the beginning of IMT-2020, and dynamic spectrum sharing (DSS) enables low investment and fast deployment with smooth evolution of Sub3G (i.e., spectrum resources below 3 GHz).
+
+However, DSS performance is not as expected due to inter-radio access technology (inter-RAT) interference; an innovative spectrum sharing solution is required for higher NR performance, called hybrid DSS. Based on the current 20 MHz long-term evolution network, an IMT-2020 carrier with large bandwidth can be rapidly deployed. A cluster DSS solution and dynamic resource sharing at the base station cluster level, which limits inter-RAT interference at the cluster boundary, improve the IMT-2020 user experience and network efficiency without impact on 4G performance.
+
+#### 9.2.4 Coverage enhancement
+
+A super uplink (SUL) solution with decoupled uplink and downlink, which has been incorporated into 3GPP Release 16, solves the bottleneck of NR carrier uplink coverage. The uplink data is transmitted over the time division duplexing (TDD) spectrum and SUL spectrum, which greatly increases the available uplink resources for IMT-2020 subscribers.
+
+An innovative fusion-assisting super TDD (FAST) solution combines a middle or low band carrier in accordance with the framework of carrier aggregation (CA), with the addition of an innovative uplink TDM CA mode. By taking full consideration of the terminal implementing differentiation and the network strategies of operators, FAST can flexibly adapt to different capabilities of the terminal to maximize system performance.
+
+Power pooling and dynamic sharing have been introduced for unified and flexible scheduling of the output power of modules, which improves the downlink experience by 5% to 20% with lower carbon.
+
+#### 9.2.5 Capacity improvement
+
+**Super frequency fusion technology**, which has been incorporated into 3GPP Release 18 for IMT-2020-advanced, greatly improves the spectrum efficiency, system capacity and user experience through simplified control channels for multi-carrier, spectrum pooling for multi-carrier and unified scheduling.
+
+**Three dimensional beam coordination with time, frequency and space domain**, achieves the best average user experience in the whole network with scheduling of full-band multi-beam formation and collaboration of multi-bands, solving the problem of unbalanced service or user distribution.
+
+**Sounding reference signal carrier** switching improves the secondary carrier experience by 30% with sounding reference signal (SRS) dispatch via a secondary carrier for self-contained timeslots and SRS dispatch via a primary carrier for other timeslots.
+
+#### 9.2.6 Interference suppression
+
+Passive interference of multi-frequency co-existence in the antenna feeder system is a difficult problem in the industry. By new architecture of multi-level cancellation, both linear and non-linear passive interference can be counteracted. The coverage has been improved by 20% with over 10 dB passive intermodulation cancellation. The technology is called **ultra-wideband passive interference self-cancellation**.
+
+In a macro-macro intra-frequency network, the interference between neighbouring cells has been decreased with **intelligent beam forming power coordination**. User speed rate increases by about 15% through coordination frequency scheduling of neighbouring cells.
+
+#### 9.2.7 Operation and dispatch
+
+**The shared operation and dispatching platform**, based on block chain technology, addresses three issues of operation: key parameters verification; configuration permissions of sharing network elements; and intelligent scheduling of contract resources. The platform empowers the whole procedure of sharing network construction, application, operation and optimization with cloud-deployment, cloud-chain and heterogeneous-cloud coordination. At the time of publication, the platform has been applied for over 600,000 sites with operation efficiency doubled.
+
+**An energy-saving platform**, powered by artificial intelligence (AI), big data and network controlling technologies, has been deployed in 31 provinces in China with over 15% energy saving for IMT-2020 sharing network.
+
+#### 9.2.8 Business-to-business private sharing network
+
+**A multi-mode resource block resource reservation strategy**, with a statistical level and transmission time interval level resource block (RB) reservation strategy, matches the differentiation requirements of services. Meanwhile, IMT-2020 user speed rate and latency have been guaranteed, especially for ultra-reliable low latency communication scenarios with RB management and scheduling. The technology has been incorporated into [b-3GPP TS 28.541]. **Multi-logic cell management of a shared carrier** is an innovative sharing solution that ensures the differentiated requirements of IMT-2020 verticals of different operators. Not only are vertical applications independently operated, but also the security of industry data can be guaranteed.
+
+## 9.3 IMT-2020 standalone international roaming under core network sharing
+
+Currently, [b-3GPP TS 23.501] only supports the sharing architecture of IMT-2020 MOCN. It is necessary to increase the research on IMT-2020 SA international roaming technology under core network sharing. It is recommended that the research and standard support of long-term architecture be increased. Accordingly, [b-3GPP TS 29.573] also needs to be reviewed to support the interconnection of a long-term security and edge protection proxy. In addition, [b-GSMA NG.113] is a guideline for IMT-2020 SA roaming, and it is recommended that support for long-term shared architecture be also added.
+
+## 9.4 Planning and construction
+
+To ensure the smooth implementation of sharing and co-construction, all parties should fully collaborate with each other in planning, construction, operation and optimization to achieve common goals, it is recommended that cooperative operators establish a joint working mode.
+
+The cooperative operators should establish an end-to-end sharing and co-construction long-term cooperation mechanism based on the information support platform, including: the organization guarantee mechanism; the evaluation system of planning, construction, maintenance and optimization; and the mechanism of assessment and incentive.
+
+#### 9.4.1 Planning
+
+In terms of joint network planning, the following are required.
+
+**Planning principle:** In response to differences in network resources and objectives of planning and construction, unification of the objectives, processes, planning, guidelines, templates and methods.
+
+**Planning methodology:** Jointly sort out the current situation; jointly judge trends, unified planning objectives, unified coordination of resources; and jointly review planning.
+
+#### 9.4.2 Construction
+
+In terms of joint network construction, the following are required.
+
+**Construction principle:** Full sharing and information equivalence; joint planning review, unified construction priority evaluation criteria, joint acceptance of engineering projects, and regular management to ensure information equivalence and timely response to sudden and changing demands.
+
+**Construction step:** Network construction is divided into four stages: solution review; infrastructure reconstruction; construction implementation; and engineering acceptance.
+
+## 9.5 Regulation and accounting or settlement
+
+Regulatory and security mechanisms shall be established.
+
+At the same time, it is necessary to study inter-network accounting or settlement, including inter-network settlement requirements and settlement principles.
+
+## 9.6 Operation and optimization
+
+In terms of network operation and optimization, exploration is required of strategies of cooperative operation, including: service resource strategy; mobility strategy; operation data sharing; collaborative network ID; network management sharing; and unified key performance indicators.
+
+# 10 Environmental impact assessment of network sharing and co-construction
+
+The environmental impact assessment (EIA) is a crucial process that evaluates the potential environmental impacts of various projects. The IMT-2020 mobile construction is one such project that has raised concerns about its environmental impact. In this clause, the EIA of IMT-2020 mobile construction and its potential environmental impact are briefly discussed.
+
+The EIA of IMT-2020 NSCC is a crucial aspect that needs to be considered before implementing this technology. IMT-2020 networks have the potential to revolutionize the way we live and work, but at the same time, they can have a significant impact on the environment.
+
+One primary concern regarding IMT-2020 NSCC is the amount of energy that will be required to power these networks. The increased speed and bandwidth of IMT-2020 networks will require more energy to operate, which could lead to an increase in GHG emissions and other environmental impacts.
+
+Another concern is the impact that IMT-2020 networks could have on wildlife and ecosystems. The installation of new infrastructure, such as cell towers and antennas, could disrupt wild habitats and migration patterns, leading to negative impacts on local wildlife populations.
+
+To address these concerns, an EIA should be conducted before implementing IMT-2020 NSCC projects. An EIA is a process that evaluates the potential environmental impacts of a proposed project and identifies ways to mitigate those impacts.
+
+The EIA process shall involve a thorough analysis of the potential energy consumption and GHG emissions associated with IMT-2020 NSCC. This analysis should consider the energy requirements
+
+of the new infrastructure, as well as the energy required to power the increased data traffic on these networks.
+
+The EIA shall also assess the potential impacts on local wildlife populations and ecosystems. This assessment should consider the potential disruptions to habitats and migration patterns caused by the installation of new infrastructure, as well as the potential impacts of increased electromagnetic radiation on wildlife.
+
+Based on the results of the EIA, measures shall be taken to mitigate any potential negative impacts of IMT-2020 NSCC. These measures can include: using renewable energy sources to power the new infrastructure (see [ITU-T L.1210] or [ETSI ES 203 700]); minimizing the number of new cell towers and antennas; and implementing measures to reduce electromagnetic radiation.
+
+In conclusion, the EIA of IMT-2020 NSCC is a critical step in ensuring that this technology is implemented in a way that minimizes its impact on the environment. By conducting a thorough EIA and implementing appropriate mitigation measures, we can ensure that we reap the benefits of IMT-2020 networks while minimizing their negative environmental impacts.
+
+For the assessment of project impact for GHG effects and energy effects, see [ITU-T L.1430].
+
+For detailed information on the EIA methodology for good (equipment) networks and services, see [ITU-T L.1410].
+
+# 11 The contribution of IMT-2020 network sharing and co-construction to climate change mitigation
+
+The contribution to climate change from IMT-2020 NSCC is mainly in terms of reduced infrastructure construction, reduced consumption of raw materials, and GHG emissions from energy consumption during operation. Table 1 shows the calculation of carbon-reduction by NSCC during operation. Table 2 provides an illustration of calculation of carbon-emission in the manufacturing phase.
+
+**Table 1 – Calculation of carbon-reduction by network sharing and co-construction**
+
+| Category | No. | Item | Unit | Annual values |
+|-----------------------|-----|-------------------------------------------------------------------------------------|------------------------|-----------------|
+| IMT-2020 SCC Stations | [1] | Total number of IMT-2020 SCC base stations | thousand | $X$ |
+| | [2] | Average power of an IMT-2020 base station 1 | kW | $Y$ |
+| | [3] | Total power savings of IMT-2020 SCC stations $\{[1]*[2]*365\text{day}*24\text{h}\}$ | MWh | $X*Y*365*24$ |
+| | [4] | Carbon emission factor (see Note 2) | tCO 2 e/MWh | $EF$ |
+| | [5] | Calculated values for total carbon reduction $\{[1]*[2]*[3]*[4]\}$ | tCO 2 e | $X*Y*365*24*EF$ |
+| 4G SCC Stations | [1] | Total number of 4G SCC base stations | thousand stations | $X$ |
+| | [2] | Average power of a 4G base station (see Note 1) | kW | $Y$ |
+| | [3] | Total power savings of 4G SCC stations $\{[1]*[2]*365\text{ day}*24\text{ h}\}$ | MWh | $X*Y*365*24$ |
+| | [4] | Carbon emission factor (see Note 2) | tCO 2 e/MWh | $EF$ |
+
+**Table 1 – Calculation of carbon-reduction by network sharing and co-construction**
+
+| Category | No. | Item | Unit | Annual values |
+|----------|-----|---------------------------------------------------------------------|--------------------|-----------------|
+| | [5] | Calculated values for total carbon reduction $\{=[1]*[2]*[3]*[4]\}$ | tCO 2 e | $X*Y*365*24*EF$ |
+
+NOTE 1 – The average power of an IMT-2020/4G base station will vary from year to year, due to the use of new materials, new manufacturing processes or new model equipment, or with the software use of emerging energy-saving technologies or AI management tools, etc.
+
+NOTE 2 – The carbon EF is the amount of carbon emissions per unit of energy produced during the combustion or use of each energy source. Based on the assumptions of the IPCC, it can be assumed that the carbon EF for a given energy source is fixed. However, this EF will vary from one country or region to another, depending on the year and regional differences.
+
+**Table 2 – Calculation of carbon emissions in the manufacturing phase of IMT-2020 stations and 4G stations**
+
+| Category | No. | Item | Unit | Annual values |
+|-------------------|-----|----------------------------------------------------------------------------------------------|---------------------------|-------------------------------------------------|
+| IMT-2020 Stations | [1] | Total number of IMT-2020 base stations | thousand | $X$ |
+| | [2] | Average energy consumption in the manufacturing phase of IMT-2020 base stations (see Note 1) | kWh | $Y$ |
+| | [3] | Average accessories (see Note 2) usage in the manufacturing phase of IMT-2020 base stations | kg | $Z_i$ |
+| | [4] | Carbon EF of grid | kg CO 2 e/ kWh | $EF_1$ |
+| | [5] | Carbon EFs for the production of accessories | kg CO 2 e/ kg | $EF_{ia}$ |
+| | [6] | Carbon EFs for the volatilization of accessories (see Note 3) | kg CO 2 e/ kg | $EF_{ib}$ |
+| | [7] | Calculated values for total carbon emission $\{=[1]*\{[2]*[4]+\sum [3]*\{[5]+[6]\}\}\}$ | tCO 2 e | $X*[Y*EF_1+\sum_{i=1}^n Z_i*(EF_{ia}+EF_{ib})]$ |
+| 4G Stations | [1] | Total number of 4G base stations | thousand | $X$ |
+| | [2] | Average energy consumption in the manufacturing phase of 4G base stations (see Note 1) | kWh | $Y$ |
+| | [3] | Average accessories (see Note 2) usage in the manufacturing phase of 4G base stations | kg | $Z_i$ |
+| | [4] | Carbon EF of grid | kg CO 2 e/ kWh | $EF_1$ |
+| | [5] | Carbon EFs for the production of accessories | kg CO 2 e/ kg | $EF_{ia}$ |
+| | [6] | Carbon EFs for the volatilization of accessories (see Note 3) | kg CO 2 e/ kg | $EF_{ib}$ |
+| | [7] | Calculated values for total carbon emission $\{=[1]*\{[2]*[4]+\sum [3]*\{[5]+[6]\}\}\}$ | tCO 2 e | $X*[Y*EF_1+\sum_{i=1}^n Z_i*(EF_{ia}+EF_{ib})]$ |
+
+**Table 2 – Calculation of carbon emissions in the manufacturing phase of IMT-2020 stations and 4G stations**
+
+| Category | No. | Item | Unit | Annual values |
+|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----|------|------|---------------|
+| NOTE 1 – The energy consumption in the manufacturing phase of IMT-2020 stations and 4G stations mainly comes from the energy consumption of production line assembly and the energy consumption of software and hardware testing. NOTE 2 – Accessories include solder paste, cleaning agent and flux. NOTE 3 – The volatile ratio of volatile organic compounds has been included in $EF_{ib}$ . | | | | |
+
+# 12 Prospect of global mobile communication network sharing and co-construction
+
+In terms of the future development direction of sharing network with global partners, the following are required.
+
+**Deepening IMT-2020 network sharing and co-construction cooperation:** The future evolution direction of IMT-2020 NSCC can be analysed from multiple dimensions such as technology route, geographical range, number of partners, working frequency bandwidth and technology systems.
+
+**Future technological evolution of sharing and co-construction:** Millimetre wave sharing and co-construction, multi-access edge computing sharing and co-construction and sixth generation (6G) NSCC.
+
+# Appendix I
+
+## The practice of IMT-2020 network sharing and co-construction in China
+
+(This appendix does not form an integral part of this Recommendation.)
+
+In 2019, China Telecom and China Unicom launched a joint project to build and share an IMT-2020 lifecycle network. Since then, both parties have made significant breakthroughs in IMT-2020 sharing technologies, components, equipment, networking and operations, and have built one physical network, two logical networks and multiple customized private networks. As the first and the largest, this IMT-2020 SA shared network has realized large-scale industrial application and ensured good user experience.
+
+### I.1 Global best practice of IMT-2020 network sharing and co-construction in China
+
+China Telecom and China Unicom are the pioneers and practitioners of IMT-2020 sharing and co-construction technology. In September 2019, China Telecom and China Unicom signed an IMT-2020 NSCC framework cooperation agreement, which clearly stated that they would build a joint IMT-2020 access network nationwide, sharing the IMT-2020 frequency resources, and building IMT-2020 core networks independently. After area demarcation, the companies build, invest, maintain and operate separately. In the subsequent implementation of IMT-2020 co-construction and sharing, China Telecom and China Unicom continue to innovate in technical solutions, cooperation models, management mechanisms, etc., which accelerates the construction of IMT-2020 networks. On 2020-09-30, the first and largest IMT-2020 sharing network finished its phase I construction and commercial deployment, which promoted IMT-2020 network construction and completed the end-to-end network evolution of the SA mode.
+
+By 2021-12-31, China Telecom and China Unicom had deployed about 700 000 base stations in IMT-2020 networks, accounting for more than 40% of the world's built IMT-2020 base stations, and built the world's first and largest IMT-2020 SA shared network, realizing large-scale industrial applications. Meanwhile, it has promoted the sharing of 4G access networks between the two partners, saving more than CNY 210 billion in network construction investment, CNY 20 billion in network operating costs, more than 10 GWh of electricity, and reducing carbon emissions by 6 Mt every year.
+
+China Telecom and China Unicom have proposed 12 international standards for IMT-2020 co-construction and sharing, forming the first national standard for wireless sharing technology, filling the gaps in wireless system sharing technology and standards, and leading a leap forward in global mobile communication network sharing.
+
+In the past three decades, a universal system has been forming in the information and communications technology industry, whose main characteristics are: alignment of standards; globalization of technologies, products and supplies; and free flow of data. Unbalanced data flow will lead to differences in the pace of network construction, fragmentation of telecommunication standards, and fragmentation of supply systems. The co-construction and sharing advocated by China coincides with the vision of the Internet of everything pursued by the telecommunication industry. The co-construction and sharing of China Telecom and China Unicom in the world's largest IMT-2020 network will greatly promote the unification of industry standards, globalization of supply chains, digitization of society, free flow of data and circulation of capital within the industry.
+
+China Telecom and China Unicom are the first in the world to carry out nationwide IMT-2020 full life cycle network co construction and sharing. With a series of innovative practices in products, technology and O&M and management, China Telecom and China Unicom have promoted sharing and co-construction and accelerated the implementation, providing Chinese experience for the global telecommunications industry.
+
+**IMT-2020 sharing and co-construction technology.** Practising in many aspects for different modes of NSA and SA, e.g., various networking schemes, coverage enhancement technology, capacity improvement, interference suppression, DSS technology, key technologies of sharing and co-construction management and scheduling strategy, shared to business private network and international roaming scheme.
+
+Taking the use case of China Telecom and China Unicom as an example, the IMT-2020 spectrum of 3.5/2.1 GHz is adjacent band, and only one set of equipment is required to support 2.1 GHz 55 MHz, 3.5 GHz 200 MHz broad bandwidth, providing better network performance. At the same time, the network resources of the two operators are highly complementary in the southern and northern regions of China. Through nationwide cooperation, an IMT-2020 joint access network will be quickly built and shared efficiently to rapidly achieve full network coverage nationwide, form IMT-2020 service capabilities, enhance the market competitiveness of IMT-2020 networks, improve network and asset operation efficiency, and achieve mutual benefit and win-win results.
+
+**IMT-2020 sharing and co-construction management.** Establishment of rules, regulations, supervisions and settlements. All partners have set up joint working organizations, established rules and regulations, reinstituted processes, ensured the operation quality of the network and the consistency of the business and user perceptions of all partners through a series of innovative solutions. Moreover, promotion of the full life cycle and whole process penetration. and coordination of planning, construction, maintenance and optimization.
+
+**IMT-2020 co-construction and shared operation.** The principle of planning, construction, maintenance and optimization runs through the whole process and cooperation. All partners have introduced dual north faced resource scheduling, slicing resource allocation, blockchain technology, and full-time shared AI energy-saving technology to further improve operational efficiency, build a mutual trust mechanism, and realize transparent, visible and efficient collaboration of all partners' operations.
+
+**Follow up evolution of co-construction and sharing.** Looking forward to the future and continuing to deepen co-construction and sharing. Such as technical route, geographical scope, number of partners, operating frequency band, technical system and other dimensions, IMT-2020 sharing and co-construction are analysed. Facing the future problems of sharing millimetre waves, chambers, edge computing and 6G, which will also continue to explore innovation and practice.
+
+### I.2 Calculation of carbon-reduction by network sharing and co-construction in China Telecom and China Unicom
+
+Table I.1 lists steps in the calculation of the electricity savings for 4G and IMT-2020 base stations by NSCC and the estimated amount of carbon reduction for China Telecom and China Unicom in 2020, 2022 and 2025.
+
+**Table I.1 – Calculation of carbon-reduction by network sharing and co-construction**
+
+| Category | No. | Item | Unit | Values for 2020 | Values for 2022 | Values for 2025 |
+|-----------------------|-----|----------------------------------------------------------------------------------------|----------|-----------------|-----------------|-----------------|
+| IMT-2020 SCC Stations | [1] | Total number of IMT-2020 SCC base stations | thousand | 400 | 1000 | [1400] |
+| | [2] | Average power of an IMT-2020 base station (see Note 1) | kW | 1.45 | 1.45 | [1.45] |
+| | [3] | Total power savings of IMT-2020 SCC stations $\{=[1]*[2]*365\text{ day}*24\text{ h}\}$ | MWh | 5 080 800 | 12 702 000 | 17 782 800 |
+
+**Table I.1 – Calculation of carbon-reduction by network sharing and co-construction**
+
+| Category | No. | Item | Unit | Values for 2020 | Values for 2022 | Values for 2025 |
+|-----------------|-----|-----------------------------------------------------------------|------------------------|-----------------|-----------------|-----------------|
+| | [4] | Carbon EF (see Note 2) | tCO 2 e/MWh | 0.581 | 0.581 | [0.581] |
+| | [5] | Calculated values for total carbon reduction {=[1]*[2]*[3]*[4]} | tCO 2 e | 2 951 944.8 | 7 379 862 | 10 331 806.8 |
+| 4G SCC Stations | [1] | Total number of 4G SCC base stations | thousand stations | 240 | 1120 | [1700] |
+| | [2] | Average power of a 4G base station(see Note 1) | kW | 0.5 | 0.5 | [0.5] |
+| | [3] | Total power savings of 4G SCC stations {=[1]*[2]*365 day*24 h} | MWh | 1 051 200 | 4 905 600 | 7 446 000 |
+| | [4] | Carbon EF (see Note 2) | tCO 2 e/MWh | 0.581 | 0.581 | [0.581] |
+| | [5] | Calculated values for total carbon reduction {=[1]*[2]*[3]*[4]} | tCO 2 e | 610 747.2 | 2 850 153.6 | 4 326 126 |
+
+NOTE 1 – The average power of an IMT-2020/4G base station will vary from year to year, due to the use of new materials, new manufacturing process or new model equipment, and with the use of emerging energy-saving technologies or AI-based management tools, etc.
+
+NOTE 2 – The carbon EF is the amount of carbon emissions per unit of energy produced during the combustion or use of each energy source. Based on the assumptions of the IPCC (United Nations Intergovernmental Panel on Climate Change), it can be assumed that the carbon EF for a given energy source is fixed. However, this EF will vary from one country or region to another, depending on the year and regional differences.
+
+Table I.2 lists steps in the calculation of carbon emission in the manufacturing phase of IMT-2020 station and 4G station (station mode: one baseband unit (BBU) plus three active antenna units (AAUs) or remote radio units (RRUs)).
+
+**Table I.2 – Calculation of carbon emissions in the manufacturing phase of IMT-2020 stations and 4G stations**
+
+| Category | No. | Item | Unit | Values for 2020 | Values for 2022 | Values for 2025 |
+|-------------------|-----|----------------------------------------------------------------------------------------------|--------------------------|-----------------|-------------------|-----------------|
+| IMT-2020 Stations | [1] | Total number of IMT-2020 base stations | thousand | 400 | 1 000 | 1 400 |
+| | [2] | Average energy consumption in the manufacturing phase of IMT-2020 base stations (see Note 1) | kWh | / | 26.45 | / |
+| | [3] | Average accessories (see Note 2) usage in the manufacturing phase of IMT-2020 base stations | kg | / | $Z_1 = 0.082$ | / |
+| | [4] | Carbon EF of grid | kg CO 2 e/kWh | / | 0.791 | / |
+| | [5] | Carbon EFs for the production of accessories | kg CO 2 e/kg | / | $EF_{1a} = 3.915$ | / |
+| | [6] | Carbon EFs for the volatilization of accessories (see Note 3) | kg CO 2 e/kg | / | $EF_{1b} = 0$ | / |
+
+**Table I.2 – Calculation of carbon emissions in the manufacturing phase of IMT-2020 stations and 4G stations**
+
+| Category | No. | Item | Unit | Values for 2020 | Values for 2022 | Values for 2025 |
+|-------------|-----|-----------------------------------------------------------------------------------------|--------------------------|-----------------|-------------------|-----------------|
+| | [7] | Calculated values for total carbon emission $\{=[1]*\{[2]*[4]+\sum [3]*\{[5]+[6]\}\}\}$ | tCO 2 e | / | 21 243 | / |
+| 4G stations | [1] | Total number of 4G base stations | thousand | 240 | 1 120 | 1 700 |
+| | [2] | Average energy consumption in the manufacturing phase of 4G base stations (see Note 1) | kWh | / | 24.50 | / |
+| | [3] | Average accessories (see Note 2) usage in the manufacturing phase of 4G base stations | kg | / | $Z_1 = 0.078$ | / |
+| | [4] | Carbon EF of grid | kg CO 2 e/kWh | / | 0.791 | / |
+| | [5] | Carbon EFs for the production of accessories | kg CO 2 e/kg | / | $EF_{1a} = 3.915$ | / |
+| | [6] | Carbon EFs for the volatilization of accessories (see Note 3) | kg CO 2 e/kg | / | $EF_{1b} = 0$ | / |
+| | [7] | Calculated values for total carbon emission $\{=[1]*\{[2]*[4]+\sum [3]*\{[5]+[6]\}\}\}$ | tCO 2 e | / | 22 047 | / |
+
+NOTE 1 – The energy consumption in the manufacturing phase of IMT-2020 stations and 4G stations mainly comes from the energy consumption of production line assembly and the energy consumption of software and hardware testing.
+
+NOTE 2 – Accessories include solder paste, cleaning agent and flux.
+
+NOTE 3 – The volatile ratio of volatile organic compounds has been included in $EF_{1b}$ .
+
+# Bibliography
+
+- [b-ISO 14064-1] ISO 14064-1:2018, *Greenhouse gases – Part 1: Specification with guidance at the organization level for quantification and reporting of greenhouse gas emissions and removals*.
+- [b-3GPP TR 21.915] Technical Report 3GPP TR 21.915 V15.0.0 (2019), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Release 15 Description; Summary of Rel-15 Work Items (Release 15)*.
+- [b-3GPP TS 23.251] Technical Specification 3GPP TS 23.251 V17.0.0 (2022), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Network sharing; Architecture and functional description (Release 17)*.
+- [b-3GPP TS 23.501] Technical Specification 3GPP TS 23.501 V18.4.0 (2023), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; System architecture for the 5G System (5GS); Stage 2 (Release 18)*.
+- [b-3GPP TS 28.541] Technical Specification 3GPP TS 28.541 V18.6.1 (2024), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Management and orchestration; 5G network resource model (NRM); Stage 2 and stage 3 (Release 18)*.
+- [b-3GPP TS 29.573] Technical Specification 3GPP TS 29.573 V18.5.0 (2023), *3rd Generation Partnership Project; Technical Specification Group Core Network and Terminals; 5G System; Public Land Mobile Network (PLMN) Interconnection: Stage 3 (Release 18)*.
+- [b-3GPP TS 37.471] Technical Specification 3GPP TS 37.471 V17.0.0 (2022), *3rd Generation Partnership Project; Technical Specification Group Radio Access Network; W1 interface; Layer 1 (Release 17)*.
+- [b-3GPP TS 37.472] Technical Specification 3GPP TS 37.472 V17.0.0 (2022), *3rd Generation Partnership Project; Technical Specification Group Radio Access Network; W1 interface; Signalling transport (Release 17)*.
+- [b-3GPP TS 37.473] Technical Specification 3GPP TS 37.473 V17.2.0 (2023), *3rd Generation Partnership Project; Technical Specification Group Radio Access Network; W1 interface; Application protocol (WIAP); (Release 17)*.
+- [b-GSMA 5G] GSMA (2023). *5G network co-construction and sharing guide*. London: Global System for Mobile Communications Association. 33 pp. Available [viewed 2024-03-17] at: [https://www.gsma.com/futurenetworks/wp-content/uploads/2023/02/5G-NCCS\\_GSMA-Guide\\_27.02.2023.pdf](https://www.gsma.com/futurenetworks/wp-content/uploads/2023/02/5G-NCCS_GSMA-Guide_27.02.2023.pdf)
+- [b-GSMA NG.113] GSMA Official Document NG.113 (2021), *5GS roaming guidelines, Version 4.0*. London: Global System for Mobile Communications Association. 53 pp. Available [viewed 2024-03-18] at:
+- [b-UN SDG] United Nations Sustainable Development Group (2024). *2030 Agenda and the sustainable development goals*. New York, NY: United Nations Sustainable Development Group. Available [viewed 2024-03-16]:
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1470-202001-I_PDF-E/raw.md b/marked/L/T-REC-L.1470-202001-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..d706f8569c9d2bb987022bb067542061c39ac9cf
--- /dev/null
+++ b/marked/L/T-REC-L.1470-202001-I_PDF-E/raw.md
@@ -0,0 +1,3178 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1470**
+
+(01/2020)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+---
+
+**Greenhouse gas emissions trajectories for the
+information and communication technology
+sector compatible with the UNFCCC Paris
+Agreement**
+
+Recommendation ITU-T L.1470
+
+# ITU-T L-SERIES RECOMMENDATIONS
+
+## **ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+## **OPTICAL FIBRE CABLES**
+
+| | |
+|-------------------------------------|-------------|
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+
+## **OPTICAL INFRASTRUCTURES**
+
+| | |
+|--------------------------------------------------------|-------------|
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+
+## **MAINTENANCE AND OPERATION**
+
+| | |
+|-------------------------------------------------|-------------|
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+
+## **PASSIVE OPTICAL DEVICES**
+
+L.400-L.429
+
+## **MARINIZED TERRESTRIAL CABLES**
+
+L.430-L.449
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T L.1470
+
+# Greenhouse gas emissions trajectories for the information and communication technology sector compatible with the UNFCCC Paris Agreement
+
+## Summary
+
+Recommendation ITU-T L.1470 provides detailed trajectories of greenhouse gas (GHG) emissions for the global information and communication technology (ICT) sector and sub-sectors that are quantified for the year 2015 and estimated for 2020, 2025 and 2030. In addition, Recommendation ITU-T L.1470 establishes a long-term ambition for 2050. The trajectories, the long-term ambition and the 2015 baseline have been derived in accordance with Recommendation ITU-T L.1450 and through complementary methods in support of the 1.5°C objective described by the IPCC in its *Special report: Global warming of 1.5°C* and in support of the Science-based Targets (SBT) initiative.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1470 | 2020-01-12 | 5 | 11.1002/1000/14084 |
+
+## Keywords
+
+Climate Change, decarbonization, ICT sector, IPCC, 1.5°C, mitigation, Paris agreement, scenarios, Science Based Targets, trajectories, UNFCCC.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2020
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+###### Page
+
+| | | |
+|------|-----------------------------------------------------------------------------------------------------------------------------------|----|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| 3.1 | Terms defined elsewhere ..... | 2 |
+| 3.2 | Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 3 |
+| 5 | Conventions ..... | 4 |
+| 6 | Prerequisites..... | 4 |
+| 6.1 | The ICT sector boundary conditions ..... | 4 |
+| 6.2 | The scope concept ..... | 5 |
+| 6.3 | The emission factor for grid electricity ..... | 5 |
+| 7 | Baseline..... | 6 |
+| 7.1 | Baseline year ..... | 6 |
+| 7.2 | Baseline for ICT sector and sub-sector energy consumption and GHG emissions ..... | 6 |
+| 8 | Selection of a global emissions scenario for 1.5°C ..... | 9 |
+| 9 | Normative reference trajectories for 1.5°C scenario ..... | 11 |
+| 9.1 | Trajectory in line with the average reduction of the IPCC P2 scenario ..... | 11 |
+| 9.2 | Trajectory in line with the average linear reduction 1.5°C scenario of the SBT initiative..... | 11 |
+| 9.3 | The electricity budget approach ..... | 12 |
+| 10 | Exploration of the possibility for the ICT sector and sub-sector trajectories to stay within the normative 1.5°C trajectory ..... | 13 |
+| 10.1 | Conditions of the sub-sectors ..... | 13 |
+| 10.2 | Trajectories including electricity supply chain and grid losses (perspective A) ..... | 14 |
+| 10.3 | Trajectories for the SBT initiative (perspective B) ..... | 17 |
+| 10.4 | Comparison of the SBT initiative trajectory with normative limits ..... | 19 |
+| 11 | Opportunities and risks for the ICT sector to attain the 1.5°C trajectory ..... | 20 |
+| 11.1 | Introduction ..... | 20 |
+| 11.2 | Opportunities – strategies to decarbonize the ICT sector until 2030 ..... | 20 |
+| 11.3 | Risks ..... | 23 |
+| | Annex A – Analysis of ICT sector and sub-sectors trajectories ..... | 24 |
+| | Appendix I – Introduction to the Science-Based Targets initiative framework ..... | 27 |
+| I.1 | Applying the SDA to ICT..... | 27 |
+| I.2 | Initial boundary conditions..... | 27 |
+| I.3 | Establishing an ICT sub-sector pathway ..... | 27 |
+| I.4 | Absolute versus SDA ..... | 28 |
+
+| | Page |
+|----------------------------------------------------------------------------------------------------------|-------------|
+| I.5 Power sector carbon emission intensity ..... | 28 |
+| Appendix II – Opportunities for the ICT sector to help decarbonize other sectors ..... | 29 |
+| Appendix III – Baseline values – Energy consumption and carbon footprints ..... | 30 |
+| III.1 Summary..... | 30 |
+| III.2 Description ..... | 33 |
+| III.3 Main data sources (in addition to academic papers) ..... | 40 |
+| Appendix IV – ICT sector trajectories for 1.5°C ..... | 45 |
+| IV.1 Step 1: ICT's own development..... | 46 |
+| IV.2 Step 2: ICT and grid development..... | 58 |
+| IV.3 Step 3: ICT and grid development plus additional purchase of renewables .. | 71 |
+| Appendix V – The importance of renewables ..... | 72 |
+| V.1 The global energy and electricity situation – some confirmation of IEA and other statistics ..... | 72 |
+| V.2 ICT footprints ..... | 76 |
+| Bibliography..... | 79 |
+
+# Introduction
+
+This Recommendation provides detailed trajectories of greenhouse gas (GHG) emissions for the global information and communication technology (ICT) sector and sub-sectors that are quantified for the year 2015 and estimated for 2020, 2025 and 2030. In addition, it establishes a long-term ambition for 2050. The trajectories, the long-term ambition and the 2015 baseline have been derived in accordance with [ITU-T L.1450] and through complementary methods in support of the 1.5°C objective described in [b-IPCC 1.5] and in support of the Science-based Targets (SBT) initiative.
+
+The *Paris agreement* of the United Nations Framework Convention on Climate Change [b-UNFCCC PA], which aims to keep a global temperature rise in 2100 well below 2°C above preindustrial levels, entered into force 2016-11-04. At the same time, private investors are increasingly requesting information about the GHG strategy of companies and the environmental impact of their activities. In this context, companies are making commitments to reduce their GHG emissions. At the end of 2018, [b-IPCC 1.5] was published, which shows the severe delta effects between a 1.5°C and 2°C scenario, implying the importance of increasing decarbonization efforts.
+
+The ICT sector, although relatively small in terms of GHG emissions compared to others, is responsible for its own footprint. The rapid growth of the ICT sector stresses the importance of addressing and limiting any increase in its footprint. However, studies of some countries have actually reported an initial decoupling of sector growth and GHG emissions [b-Malmodin, Lundén 2016]. Notwithstanding, the ICT sector still represents a significant part of overall GHG emissions, and it is crucial for it to determine how it could comply with a 1.5°C trajectory.
+
+In order to establish an ICT sector trajectory, a collaboration was initiated between the ITU, Science Based Targets (SBT) initiative, GSM Association (GSMA) and Global Enabling Sustainability Initiative (GeSI) to develop sectoral decarbonization pathways in order to help ICT companies to set targets in line with climate science.
+
+The SBT initiative framework is further described in Appendix I. The main documents published by the SBT initiative are: [b-SBT Foundations], [b-SBT Manual], [b-SBT Criteria] and [b-SBT SDA].
+
+This collaboration is intended to establish a comprehensive understanding of the ICT sector footprint and how it could be reduced. In particular, ITU as the United Nations (UN) agency concerned with ICT should have a clear view regarding climate impacts of the technology.
+
+This Recommendation takes a normative approach towards a 1.5°C trajectory by establishing it as an upper limit for the ICT sector footprint based on the P2 scenario of [b-IPCC 1.5], the 1.5°C average pathway established by the SBT initiative and an electricity budget approach. Moreover, the sector's ability to stay within the normative limits is explored with regards to the footprint and development of the sector. It is shown that the sector could be kept within the normative limits through continued efficiency measures and increased use of low-carbon electricity supply (ES).
+
+As a next step, the trajectories described in this Recommendation will be used as input for the development of guidance at an organizational level to help ICT companies define science-based targets in line with the sector and sub-sector trajectories.
+
+[b-UNFCCC PA] commits parties to "Holding the increase in the global average temperature to well below 2°C above pre-industrial levels and pursuing efforts to limit the temperature increase to 1.5°C above pre-industrial levels". In line with this, the SBT initiative allows targets to align with either well below 2°C or with 1.5°C limits. However, the SBT initiative strongly encourages companies to aim for the more ambitious 1.5°C limit. For this reason, the remainder of this Recommendation provides trajectories aligned to 1.5°C.
+
+However, while striving to implement the decarbonization trajectory, it is important to understand that ICT, unlike many products and services sold in the world today, distinguishes itself by its double-edged nature.
+
+On the one hand, ICTs have an environmental impact at each stage of their life cycle, from energy and natural resource consumption to e-waste. On the other, ICTs can enable vast efficiencies in lifestyle and in all sectors of the economy through the provision of digital solutions that can improve energy efficiency, inventory management and business efficiency by reducing travel and transportation, e.g., teleworking and videoconferencing and by substituting physical products for digital information. The latter capacity is referred to collectively as second order or enablement effects.
+
+Beyond this, ICT has effects at the societal level by reshaping how people lead their lives. Such effects are much larger than the footprint itself and are important aspects to consider when optimizing the overall decarbonization of society. For further details, see Appendix II. However, such societal optimization lies outside the scope of this Recommendation, which is focused entirely on the footprint.
+
+Last, as the ICT sector is fast moving, the trajectories developed at this point will need regular review over coming years.
+
+# Recommendation ITU-T L.1470
+
+# Greenhouse gas emissions trajectories for the information and communication technology sector compatible with the UNFCCC Paris Agreement
+
+# 1 Scope
+
+This Recommendation provides detailed trajectories of greenhouse gas (GHG) emissions for the global information and communication technology (ICT) sector and sub-sectors that are quantified for the year 2015 and estimated for 2020, 2025 and 2030. In addition, it defines a long-term ambition for 2050. The trajectories, the long-term ambition and the 2015 baseline have been derived in accordance with [ITU-T L.1450] and through complementary methods in support of the 1.5°C objective described by the IPCC in its *Special report: Global warming of 1.5°C* [b-IPCC 1.5] and in support of the Science Based Targets (SBT) initiative.
+
+This edition of this Recommendation includes mobile networks, fixed networks, data centres, enterprise networks and end-user devices, but excludes ICT services.
+
+The 1.5°C trajectories are developed from two different perspectives as follows.
+
+- A life cycle-based carbon footprint of the ICT sector to help ITU as the United Nations (UN) agency concerned with ICT to establish a clear view regarding ICT's potential climate impacts in a 1.5°C scenario.
+- An ICT sector trajectory in support of the SBT initiative to help ICT companies to set 1.5°C aligned targets in line with science is the main focus of the collaboration between the SBT initiative, GSMA, GESI and ITU. As a next step, guidance will be developed to help companies to set their own science-based targets in line with these trajectories.
+
+The difference between the two perspectives A and B is that the latter does not allocate to the sector emissions related to the electricity supply (ES) chain and grid losses associated with the use of electricity in the ICT sector. The former more inclusive approach is aligned with life cycle assessment (LCA) practice and is in line with other Recommendations in the ITU-T L.1400 series. The latter approach is established as company accounting practice by the GHG protocol.
+
+As the ICT sector is fast moving the trajectories developed at this point will need regular review over coming years.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T L.1420] Recommendation ITU-T L.1420 (2012), *Methodology for energy consumption and greenhouse gas emissions impact assessment of information and communication technologies in organizations*.
+- [ITU-T L.1450] Recommendation ITU-T L.1450 (2018), *Methodologies for the assessment of the environmental impact of the information and communication technology sector*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 carbon budget** [b-SBT Manual]: The estimated amount of carbon (or CO2 ) the world can emit before warming will exceed specific temperature thresholds.
+
+**3.1.2 emissions intensity target** [b-SBT Manual]: A reduction in emissions relative to a specific business metric, such as production output or financial performance of the company (e.g., tonne CO2 e per tonne product produced or value added). The target is achieved by a target year relative to levels in a base year.
+
+**3.1.3 emissions scenario** [b-SBT Manual]: A forecast of future emissions and atmospheric GHG concentrations, used to assess the impact of socioeconomic and technological changes on future emissions.
+
+**3.1.4 end-user** [b-ITU-T Y.1910]: The actual user of the products or services.
+
+NOTE 1 – The end-user consumes the product or service. An end-user can optionally be a subscriber.
+
+NOTE 2 – The end-user could be either a company or a consumer.
+
+**3.1.5 end-user goods** [b-ITU-T L.1410]: Any device that can connect to CPE or networks.
+
+EXAMPLE – Laptop, mobile phone.
+
+**3.1.6 Energy technology perspectives (ETP)** [b-SBT Manual]: Document published by the IEA that provides scenarios that set out pathways to a sustainable energy future in which technology choices are driven by costs and environmental factors.
+
+NOTE – The current edition is [b-IEA ETP 2017].
+
+**3.1.7 ICT manufacturer** [b-ITU-T L.1410]: Organization which has the financial and organizational control of the design and production of ICT goods.
+
+**3.1.8 target year** [b-SBT Manual]: The year by which a company intends to meet the emissions reduction committed to in a target.
+
+**3.1.9 scope 1 emission** [ITU-T L.1450]: Greenhouse gas (GHG) emission from sources owned or controlled by an organization.
+
+**3.1.10 scope 2 emission** [ITU-T L.1450]: On site greenhouse gas (GHG) emission from the generation of electricity, heat or steam that has been purchased by the reporting organization.
+
+**3.1.11 scope 3 emission** [ITU-T L.1450]: Any other indirect greenhouse gas (GHG) emissions from sources that are located along the reporting organization's value chain.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 2°C scenario (2DS)**: An emissions scenario that describes an energy system consistent with an emissions trajectory that would give a 50% chance of limiting average global temperature increase to 2°C.
+
+NOTE – This scenario is developed in [b-IEA ETP 2017].
+
+**3.2.2 enterprise network:** An internal network of an enterprise that connects computers and related devices across departments and workgroups to each other and to the Internet.
+
+**3.2.3 ICT supplier:** Organization that provides information and communication technology (ICT) products or services to an ICT organization.
+
+**3.2.4 operator:** An organization operating networks, data centres or services.
+
+NOTE – Based on clause 3.2.42 of [b-ITU-T L.1410], which defines an operator as "Organization operating networks and services".
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|-------------------------------------------|
+| 2DS | 2°C Scenario |
+| 2G | Second Generation |
+| 3G | Third Generation |
+| 4G | Fourth Generation |
+| 5G | Fifth Generation |
+| AC | Alternating Current |
+| B2DS | Beyond 2°C Scenario |
+| BAU | Business As Usual |
+| BD | Blu-ray Disc |
+| BECCS | Bioenergy with Carbon Capture and Storage |
+| CDR | Carbon Dioxide Removal |
+| CHP | Combined Heat and Power |
+| CPE | Customer Premises Equipment |
+| DC | Direct Current |
+| DVD | Digital Versatile Disc |
+| EFG | Emission Factor at Generation |
+| ES | Electricity Supply |
+| ETP | Energy Technology Perspectives |
+| GHG | Greenhouse Gas |
+| GPS | Global Positioning System |
+| HD | High Definition |
+| ICT | Information and Communication Technology |
+| IoT | Internet of Things |
+| IP | Internet Protocol |
+| IT | Information Technology |
+| LAN | Local Area Network |
+| LCA | Life Cycle Assessment |
+| M2M | Machine to Machine |
+
+| | |
+|------|-----------------------------------|
+| NDA | Non-Disclosure Agreement |
+| PC | Personal Computer |
+| PES | Primary Energy Supply |
+| POTS | Plain Old Telephone Service |
+| PPA | Power Purchase Agreement |
+| PSTN | Public Switched Telephone Network |
+| PUE | Power Usage Effectiveness |
+| REC | Renewable Energy Certificate |
+| SDA | Sectoral Decarbonization Approach |
+| STB | Set-Top Box |
+| SIM | Subscriber Identity Module |
+| T&D | Transmission and Distribution |
+| VoIP | Voice over Internet Protocol |
+
+# 5 Conventions
+
+In Figure 1 and certain tables in this Recommendation, green denotes the perspective of a manufacturer, yellow that of an operator, while white represent the perspective of suppliers and end-users. For example, scope 1 and 2 emissions (see clauses 3.1.9 and 3.1.10) for an ICT manufacturer will be scope 3 emissions (see clause 3.1.11) for ICT suppliers, ICT operators and non-sector end users. Care has been taken in the trajectories presented in this Recommendation to ensure no double counting has taken place.
+
+# 6 Prerequisites
+
+## 6.1 The ICT sector boundary conditions
+
+The ICT sector is defined from the perspective of its deliverables in accordance with Annex A of [ITU-T L.1450]. Sub-sectors are defined in accordance with clauses A.2 to A.6 of [ITU-T L.1450].
+
+The ICT sector definition is derived from the Organisation for Economic Co-operation and Development (OECD) sector definition in accordance with Appendix I of [ITU-T L.1450] as the OECD definition could not be applied directly since it was established for another purpose (classification of companies).
+
+This edition of this Recommendation excludes ICT services, but includes:
+
+- mobile networks;
+- fixed networks;
+- data centres;
+- enterprise networks; and
+- end-user goods.
+
+NOTE – As [ITU-T L.1450] uses the OECD sector definition as a starting point, this Recommendation follows in the same direction. At this point, the OECD definition has not been compared to that of [b-ISIC] for the sake of this Recommendation.
+
+## 6.2 The scope concept
+
+The trajectories of this Recommendation and their background information are structured to facilitate the development of guidance for company level target setting. For this reason, the scope concept, which allocates company GHG emissions into three different scopes, is applied throughout this Recommendation. Such scopes are used by [ITU-T L.1420] and in the GHG protocol ([b-GHG P], [b-GHG P Sc2], [b-GHG P Sc3]) company reporting, which is referred to by the SBT initiative framework (see Appendix I). Sector trajectories are thus designed to be consistent with company reporting of GHG emissions as specified in the GHG protocol, [ITU-T L.1420] and [ISO 14064-2].
+
+More specifically the three scopes could be described as:
+
+- scope 1, which covers direct emissions emanating from the company's own assets;
+- scope 2, which covers emissions related to purchased energy;
+- scope 3, which covers remaining value chain emissions over which the company has some influence.
+
+NOTE 1 – The SBT initiative requires a company to set one target for its combined scope 1 and 2 emissions, and in many cases also a separate target for its scope 3 emissions.
+
+To illustrate the complexity of the scope concept, Figure 1 shows how scopes for companies at different points of the ICT value chain are connected. Clause 5 specifies the significance of colours used in Figure 1.
+
+
+
+The diagram illustrates the flow of emissions across the ICT value chain. At the top, four actors are listed: Suppliers, Manufacturers, Operators, and End-users. Below them, a grid shows the scope of emissions for each actor.
+
+
+- Suppliers:** Their own Scope 1 and 2 emissions are shown in a blue box. Their Scope 3 emissions are shown in a green box.
+- Manufacturers:** They receive Scope 3 emissions from Suppliers (indicated by a right arrow). Their own Scope 1 and 2 emissions are in a blue box. Their Scope 3 emissions are in a green box.
+- Operators:** They receive Scope 3 emissions from Manufacturers (indicated by a right arrow). Their own Scope 1 and 2 emissions are in a blue box. Their Scope 3 emissions are in a green box.
+- End-users:** They receive Scope 3 emissions from Operators (indicated by a right arrow). Their own Scope 1 and 2 emissions are in a blue box. Their Scope 3 emissions are in a green box.
+
+ Additionally, there are horizontal arrows showing how one actor's Scope 1 and 2 emissions become another actor's Scope 3 emissions:
+
+
+- Suppliers' Scope 1 and 2 emissions become part of Manufacturers' Scope 3 (right arrow).
+- Manufacturers' Scope 1 and 2 emissions become part of Operators' Scope 3 (right arrow).
+- Operators' Scope 1 and 2 emissions become part of End-users' Scope 3 (right arrow).
+
+ A dashed line encloses Manufacturers and Operators, indicating they are part of the same sector. A small label 'L.1470(20)\_F01' is at the bottom right.
+
+Figure 1: Scope 1-2 emissions from the perspective of suppliers, manufacturers, operators and end-users and how they form part of scope 3 emissions of other actors. The diagram shows four actors: Suppliers, Manufacturers, Operators, and End-users. It illustrates how Scope 1 and 2 emissions for one actor become Scope 3 emissions for another. For example, Suppliers' Scope 1 and 2 emissions are part of Manufacturers' Scope 3. Manufacturers' Scope 1 and 2 emissions are part of Operators' Scope 3. Operators' Scope 1 and 2 emissions are part of End-users' Scope 3. The diagram uses color-coded boxes (green for Scope 3, yellow for Scope 3, and blue for Scope 1 and 2) and arrows to show the flow of emissions between actors. A dashed line groups Manufacturers and Operators together.
+
+**Figure 1 – Scope 1-2 emissions from the perspective of suppliers, manufacturers, operators and end-users and how they form part of scope 3 emissions of other actors**
+
+NOTE 2 – In Figure 1, end-user refers to consumers and organizations outside the ICT sector. However, in some cases, the end-use occurs within the sector.
+
+Figure 1 shows how scope 1, 2 and 3 emissions relate to each other along the ICT value chain.
+
+## 6.3 The emission factor for grid electricity
+
+The ICT sector footprint largely depends on the use of electricity and its carbon intensity. For this reason, the emission factor of grid electricity is important. According to other Recommendations in the ITU-T L.1400 series and LCA practice, the ES chain and distribution losses that occur between the point of production and the actual consumption of electricity are allocated to the ICT footprint, while according to company accounting practices used by the SBT initiative and the GHG protocol these are excluded from ICT company scopes 1 and 2, and regarded as scope 3. Consequently, the emission factors differ between the two perspectives listed in clause 1 and two sets of factors are used in line with Table 1.
+
+The grid emission intensity for the period 2015-2020 reflects actual conditions of the ICT sector, including its geographical distribution in line with [b-Malmodin 2018c]. The intensities for 2025, 2030 and 2050, shown in Table 1 are in line with the [b-IEA ETP 2017] beyond 2°C scenario (B2DS) that has been remodelled by the SBT initiative to align with [b-IPCC 1.5] 1.5°C pathways.
+
+**Table 1 – Electricity emission factors**
+
+| Year | 2025 | 2030 | 2050 |
+|----------------------------------------------------------------------------------------------------------------|-------|-------|-------|
+| Emission factors including electricity supply chain and grid losses (kg CO 2 e/kWh) (perspective A) | 0.351 | 0.200 | 0.000 |
+| Emission factors used for the SBT initiative (kg CO 2 e/kWh) (perspective B) | 0.281 | 0.160 | 0.000 |
+
+NOTE 1 – The emission factors used for grid electricity for the trajectories are based on a development in line with a 1.5°C trajectory with extensive progress on renewables and efficiency embedded. Such a development might not happen. See clause 11.3 for further details on risks.
+NOTE 2 – These values represent intermediate work by the SBT initiative and are not finalized.
+
+# 7 Baseline
+
+## 7.1 Baseline year
+
+The baseline year for the ICT sector decarbonization trajectory is set to 2015.
+
+## 7.2 Baseline for ICT sector and sub-sector energy consumption and GHG emissions
+
+The baseline footprint of the ICT sector and sub-sectors is in accordance with Table 1 and was derived in accordance with the methodology outlined in [ITU-T L.1450]. Details on assumptions, calculations and data behind these values, as well as details regarding the degree of [ITU-T L.1450] compliance, are given in Appendix III.
+
+Columns 3 and 4 of Table 2 list carbon dioxide equivalent (CO2 e) emissions that reflect perspectives A and B of clause 1. Column 1 lists power sector supply chain and distribution grid losses to align with perspective A. Column 2 considers the use of grid electricity in line with the SBT initiative and the GHG protocol scope 2 [b-GHG P Sc2] accounting which excludes ES chain and grid losses (perspective B). See clause 6.3 for more details.
+
+**Table 2 – ICT sector baseline for 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | ITU-T L.1400 series-aligned baseline | SBT initiative-aligned baseline |
+| Mobile networks | | Perspective A | Perspective B |
+| Mobile network manufacturers | 5 | 3 | 3 |
+
+**Table 2 – ICT sector baseline for 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|-------------------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | ITU-T L.1400 series-aligned baseline | SBT initiative-aligned baseline |
+| Mobile network manufacturers, transmission and distribution (T&D) | | 0.3 | – |
+| Mobile network manufacturers, electricity supply | | 0.45 | – |
+| Mobile network operator overheads – electricity | 13 | 6.4 | 6.4 |
+| Mobile network operator overheads – excluding electricity | | 4 | 4 |
+| Mobile network own electricity generation | 27 | 25 | 25 |
+| Mobile network electricity consumption | 90 | 48 | 48 |
+| Mobile network electricity consumption, T&D | | 5.4 | – |
+| Mobile network electricity consumption, electricity supply | | 8.2 | – |
+| Mobile network supply chain | | 12 | 12 |
+| Mobile network supply chain, T&D | | 0.75 | – |
+| Mobile network supply chain, electricity supply | | 1.5 | – |
+| Fixed networks | | | |
+| Fixed network manufacturers | 1.7 | 1 | 1 |
+| Fixed network manufacturers, T&D | | 0.1 | – |
+| Fixed network manufacturers, electricity supply | | 0.15 | – |
+| Fixed network operator overheads – electricity | 7 | 3.2 | 3.2 |
+| Fixed network operator overheads – excluding electricity | | 2 | 2 |
+| Fixed network electricity consumption | 85 | 43.2 | 43 |
+| Fixed network electricity consumption, T&D | | 4.6 | – |
+| Fixed network electricity consumption, supply | | 6.9 | – |
+| Fixed network supply chain | | 4.5 | 6 |
+| Fixed network supply chain, T&D | | 0.5 | – |
+| Fixed network supply chain, electricity supply | | 0.75 | – |
+| Data centres | | | |
+| Data centre manufacturers | 5 | 3 | 3 |
+| Data centre manufacturers, T&D | | 0.3 | – |
+| Data centre manufacturers, electricity supply | | 0.45 | – |
+| Data centre operator overheads (electricity) | 15 | 6.4 | 6.4 |
+
+**Table 2 – ICT sector baseline for 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|---------------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | ITU-T L.1400 series-aligned baseline | SBT initiative-aligned baseline |
+| Data centre operator overheads (excluding electricity) | | 3 | 3 |
+| Data centre electricity consumption | 205 | 91.2 | 91.2 |
+| Data centre electricity consumption, T&D | | 9.1 | – |
+| Data centre electricity consumption, supply | | 13.7 | – |
+| Data centre supply chain 2) | | 12 | 12 |
+| Data centre supply chain, T&D | | 0.75 | – |
+| Data centre supply chain, electricity supply | | 1.5 | – |
+| User devices | | | |
+| User devices manufacturers (non-electricity) | | 35 | 35 |
+| User devices manufacturers electricity | 149 | 70 | 70 |
+| User devices manufacturers, T&D | | 7 | – |
+| User devices manufacturers, electricity supply | | 10.5 | – |
+| User devices operation | 345 | 169 | 169 |
+| User devices operation (T&D) | | 17 | – |
+| User devices operation, electricity supply | | 25 | – |
+| User devices supply chain non-electricity | | 35 | 35 |
+| User devices supply chain, electricity | 56 | 26 | 26 |
+| User devices supply chain, T&D | | 2.6 | – |
+| User devices supply chain, electricity supply | | 3.9 | – |
+| Enterprise networks | | | |
+| Enterprise networks manufacturers electricity | | 0.5 | 0.5 |
+| Enterprise networks manufacturers, T&D | | 0.05 | – |
+| Enterprise networks devices manufacturers, electricity supply | | 0.08 | – |
+| Enterprise networks operation | 25 | 12 | 12 |
+| Enterprise networks operation (T&D) | | 1.2 | – |
+| Enterprise networks operation (supply) | | 1.8 | – |
+| Total | | | |
+| Total including grid electricity supply and losses | | 740 | – |
+| Total excluding grid electricity supply and losses | | – | 617 |
+
+**Table 2 – ICT sector baseline for 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|---------------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | ITU-T L.1400 series-aligned baseline | SBT initiative-aligned baseline |
+| Number of mobile subscriptions (SIM-cards excluding M2M) | 7.2 billion | | |
+| Number of fixed subscriptions (lines) | 1.85 billion | | |
+| Number of servers (data centres) | 43 million | | |
+| Number of active PC or employee "users" (enterprises) | 800 million | | |
+| Number of end-user goods | 13 billion | | |
+| Number of additional IoT/M2M (possible, included in forecast) | 2 billion | | |
+| Fixed data traffic (ZB) | 1 | | |
+| Mobile data-traffic (ZB) | 0.06 | | |
+
+This table is colour-coded in accordance with clause 5.
+NOTE – Given the data available in 2019 and collected from the sources used for the baseline [b-Malmodin 2018c] and applying the same methodology, GHG emissions for the ICT sector in 2020 are expected to remain relatively similar to the 2015 baseline.
+
+# 8 Selection of a global emissions scenario for 1.5°C
+
+In line with clause 9 of [ITU-T L.1450], a relevant global emissions scenario should be identified as a reference for the ICT trajectories.
+
+For worldwide overall GHG emissions, the scenario P2 described in [b-IPCC1.5] (see Figure 2) is selected. This scenario has been chosen as it seems to provide an adequate balance between major efforts required on GHG emissions reduction, while not relying heavily on the development of GHG sinks.
+
+
+
+**Global total net CO2 emissions**
+Billion tonnes of CO2 /yr
+
+**Non-CO2 emissions relative to 2010**
+Emissions of non-CO2 forcers are also reduced or limited in pathways limiting global warming to 1.5°C with no or limited overshoot, but they do not reach zero globally.
+
+**Methane emissions**
+
+**Black carbon emissions**
+
+**Nitrous oxide emissions**
+
+**Timing of net zero CO2 **
+Line widths depict the 5-95th percentile and the 25-75th percentile of scenarios
+
+Four illustrative model pathways: P1, P2, P3, P4
+
+Pathways limiting global warming to 1.5°C with no or low overshoot
+Pathways with high overshoot
+Pathways limiting global warming below 2°C (Not shown above)
+
+The main panel shows global net anthropogenic CO2 emissions in pathways limiting global warming to 1.5°C with no or limited (less than 0.1°C) overshoot and pathways with higher overshoot. The shaded area shows the full range for pathways analysed in [b-IPCC 1.5]. The panels on the right show non-CO2 emissions ranges for three compounds with large historical forcing and a substantial portion of emissions coming from sources distinct from those central to CO2 mitigation. Shaded areas in these panels show the 5–95% (light shading) and interquartile (dark shading) ranges of pathways limiting global warming to 1.5°C with no or limited overshoot. Box and whiskers at the bottom of the figure show the timing of pathways reaching global net zero CO2 emission levels, and a comparison with pathways limiting global warming to 2°C with at least 66% probability. Four illustrative model pathways are highlighted in the main panel and are labelled P1, P2, P3 and P4, corresponding to the LED, S1, S2, and S5 pathways.
+
+Figure 2a: Global total net CO2 emissions and non-CO2 emissions relative to 2010. The main panel shows global net CO2 emissions in billion tonnes of CO2/yr from 2010 to 2100. Four illustrative model pathways (P1, P2, P3, P4) are highlighted. The right panels show non-CO2 emissions (Methane, Black carbon, Nitrous oxide) relative to 2010. A legend at the bottom indicates the timing of net zero CO2 emissions.
+
+Source: Global warming of 1,5°C, Ipcc; Special report
+
+
+
+**Breakdown of contributions to global net CO2 emissions in four illustrative model pathways**
+
+● Fossil fuel and industry ● AFOLU ● BECCS
+
+Billion tonnes CO2 per year (GtCO2 /yr)
+
+**P1**
+P1: A scenario in which social, business and technological innovations result in lower energy demand up to 2050 while living standards rise, especially in the global South. A downsized energy system enables rapid decarbonization of energy supply. Afforestation is the only CDR option considered; neither fossil fuels with CCS nor BECCS are used.
+
+**P2**
+P2: A scenario with a broad focus on sustainability including energy intensity, human development, economic convergence and international cooperation, as well as shifts towards sustainable and healthy consumption patterns, low-carbon technology innovation, and well-managed land systems with limited societal acceptability for BECCS.
+
+**P3**
+P3: A middle-of-the-road scenario in which societal as well as technological development follows historical patterns. Emissions reductions are mainly achieved by changing the way in which energy and products are produced, and to a lesser degree by reductions in demand.
+
+**P4**
+P4: A resource- and energy-intensive scenario in which economic growth and globalization lead to widespread adoption of greenhouse-gas-intensive lifestyles, including high demand for transportation fuels and livestock products. Emissions reductions are mainly achieved through technological means, making strong use of CDR through the deployment of BECCS.
+
+Figure 2a (continued): Breakdown of contributions to global net CO2 emissions in four illustrative model pathways. The figure shows four stacked area charts (P1, P2, P3, P4) representing contributions from Fossil fuel and industry (grey), AFOLU (orange), and BECCS (yellow) from 2020 to 2100. Below each chart is a description of the pathway scenario.
+
+Characteristics of four illustrative model pathways in relation to global warming of 1.5°C introduced in Figure 2 a). These pathways were selected to show a range of potential mitigation approaches and vary widely in their projected energy and land use, as well as their assumptions about future socio-economic developments, including economic and population growth, equity and sustainability. A breakdown of the global net anthropogenic CO2 emissions into the contributions in terms of CO2 emissions from fossil fuel and industry; agriculture, forestry and other land use (AFOLU); and bioenergy with carbon capture and storage (BECCS) is shown. AFOLU estimates reported here are not necessarily comparable with countries' estimates. Further characteristics for each of these pathways are listed below each pathway. These pathways illustrate relative global differences in mitigation strategies, but do not represent central estimates, national strategies, and do not indicate requirements. For comparison, the right-most column shows the interquartile ranges across pathways with no or limited overshoot of 1.5°C. Pathways P1, P2, P3 and P4 correspond to the LED, S1, S2, and S5 pathways assessed in Figure 2a).
+
+Source: [b-IPCC 1.5]
+
+**Figure 2 – [b-IPCC 1.5] 1.5°C scenarios including the selected P2 scenario**
+
+The P2 scenario means that emissions should be reduced by approximately 50% by the year 2030 compared to 2015, and then further decline until 2050.
+
+# 9 Normative reference trajectories for 1.5°C scenario
+
+The trajectories outlined in this clause sets the limits within which the ICT trajectory shall be held to keep consistency with 1.5°C.
+
+## 9.1 Trajectory in line with the average reduction of the IPCC P2 scenario
+
+This clause shows how the ICT sector should evolve to align with the global average in line with the IPCC P2 scenario.
+
+An approach following the average required reduction according to the IPCC P2 scenario would require that the proportions of reduction of GHG emissions for the ICT sector in 2025 and 2030 are the same as the proportions of reduction required at worldwide level for all sectors of the economy.
+
+If applying an absolute contraction approach following the IPCC P2 scenario, the 1.5°C trajectory, reported in Table 3, would apply to the ICT sector.
+
+**Table 3 – IPCC P2 pathway until 2030**
+
+| Year | P2 reduction relative to 2015, % |
+|------|----------------------------------|
+| 2025 | -20 |
+| 2030 | -50 |
+
+It is noted that electrification is one of the earliest strategic steps to be taken towards decarbonization of society. From this perspective, the ICT sector – whose life cycle footprint is at least 80% based on the use of electricity – is considered to be a relatively easy to abate sector compared to sectors that are yet to be electrified. The ICT sector would be expected to decarbonize at least as fast, if not faster, than the required overall average reduction. However, due to the uneven availability of renewables and the geographic distribution of the sector, decarbonization may be more challenging than average conditions imply. Moreover, trajectories should not restrict the ability of ICT to bring innovations that can help to mitigate GHG emissions in other sectors.
+
+In the longer term, the IPCC P2 trajectory shows a GHG emissions reduction of about 88% in 2050. Remaining emissions should be net zeroed by 2050 with carbon dioxide removals (CDRs), e.g., carbon sinks, BECCS and direct air capture.
+
+## 9.2 Trajectory in line with the average linear reduction 1.5°C scenario of the SBT initiative
+
+This clause shows how the ICT sector should evolve to align with the global average decarbonization rate derived by the SBT initiative for 1.5°C.
+
+In their approach, the SBT initiative took multiple IPCC scenarios, including P2, removed outliers that were considered implausible, and established absolute contraction pathway rates associated with both 1.5°C and well below 2°C limits. According to the SBT initiative, SBTs need to be near term and may not be set beyond 2035. Reflecting that the required pathways are steepest up until 2035, p. 21 of [b-SBT Manual] states that
+
+The minimum reduction required for targets in line with well-below 2°C scenarios is 2.5% in annual linear terms. Companies, particularly those in developed countries, are strongly encouraged to adopt targets with a 4.2% annual linear reduction to be aligned with limiting warming to 1.5°C.
+
+If an absolute contraction approach is followed based on the SBT initiative approach, the 1.5°C trajectory listed in Table 4 would apply to the ICT sector.
+
+**Table 4 – The SBT initiative 1.5°C pathway to 2030**
+
+| Year | The SBT initiative (4.2% reduction relative to 2020), % |
+|-------------|----------------------------------------------------------------|
+| 2025 | –21 |
+| 2030 | –42 |
+
+P. 5 of [b-SBT Criteria] states that,
+
+Targets that cover more than 15 years from the date of submission are considered long-term targets. Companies are encouraged to develop such long-term targets up to 2050 in addition to the required mid-term targets. Long-term targets must be consistent with the level of decarbonization required to keep global temperature increase to well below 2°C compared to pre-industrial temperatures to be validated and recognized by the SBTi.
+
+It should be noted that offsets cannot be considered in meeting an SBT initiative-approved target. However, a long-term target for the ICT sector would be to achieve net zero emissions by 2050. This is consistent with SBT initiative requirements and is aligned with a 1.5°C trajectory, while also recognizing the high level of electricity usage by the sector.
+
+## 9.3 The electricity budget approach
+
+The third normative approach considers the global need for electricity as outlined by the International Energy Agency (IEA) for different scenarios and develops an interim 1.5°C scenario within which ICT should not expand its current share of electricity.
+
+This electricity budget uses the IEA trajectories for 2DS and B2DS to derive a 1.5°C trajectory for world electricity usage through doubling the difference between them and subtract it from 2DS [b-IEA ETP 2017]. This is an interim approach, as IEA has not yet defined a 1.5°C scenario.
+
+The budget is then used to define the amount of electricity that could be used by the sector if keeping its share at the current level.
+
+**Table 5 – The electricity budget**
+
+| | Electricity (TWh) | | | |
+|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|-------------|-------------|-------------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Energy-sector development (electricity budget) | | | | |
+| 1.5°C grid emission factors 2015–2020: [b-IEA ETP]; 2025–2030 SBT initiative | 0.484 | 0.48 | 0.281 | 0.160 |
+| Reduction in emission factor from 2015 value (%) | | | 42 | 67 |
+| [b-IEA ETP 2017] 1.5°C (estimate) global electricity generation (TWh) | 24 185 | 26 013 | 27 841 | 30 478 |
+| Increase in energy generation from 2015 (%) | | 8 | 15 | 26 |
+| Reduction in energy sector emissions between 2015 and 2031 when considering emission factor development and increase in energy generation according to this table (%) | | | | 58 |
+
+NOTE 1– Some sources of ICT emissions may be easier or harder to abate. In particular, the overall ICT trajectory shall respect all three normative limits in this clause at the same time.
+NOTE 2– Although the electricity budget approach starts from electricity usage, the final trajectory is defined in terms of GHG emissions, which allows for a greater flexibility between electricity efficiency and electricity emission factor measures when defining company level targets.
+
+# **10 Exploration of the possibility for the ICT sector and sub-sector trajectories to stay within the normative 1.5°C trajectory**
+
+This clause explores ICT sector development and presents a scenario that is then checked for compatibility with the normative trajectories defined in clause 9.
+
+The trajectories outlined in this clause are based on the inputs and analysis described in Appendix IV. Clause 10.1 briefly introduces conditions of the different sub-sectors that will impact their development during the coming decade. Clause 10.2 presents the trajectories with regards to perspective A. Clause 10.3 presents the trajectories to be used for the SBT initiative in line with perspective B. The difference between perspectives A and B is that the latter does not allocate emissions from the ES chain and grid losses associated with the use of electricity by ICTs to the ICT sector. The former calculation method is applied in LCAs. The latter is established as a company accounting practice by the GHG protocol.
+
+## **10.1 Conditions of the sub-sectors**
+
+This clause summarizes some high-level trends that will impact the footprint of the ICT sector and its sub-sectors moving forward. Details are given in Appendix IV.
+
+#### **10.1.1 Mobile networks**
+
+The mobile sector is associated with a very dynamic market development. To take into account these key aspects that impact the development of the footprint of mobile communications, the following trends have been considered:
+
+- subscriptions increase;
+- second generation/third generation (2G/3G) starting to decline – decommissioning or equipment modernization;
+- fourth generation (4G) continuing to develop and expanding in some markets;
+- fifth generation (5G) commissioning in some markets with rapid expansion;
+- expansion of Internet of things/machine to machine (IoT/M2M);
+- energy efficiency improvements based on new technologies;
+- build out of new networks based on population growth;
+- diesel usage reducing, but only partially phased out.
+
+Further details are provided in Appendix IV.
+
+#### **10.1.2 Fixed networks**
+
+The fixed operation footprint is expected to decrease as the old public switched telephone network (PSTN), which is an energy intensive system, is used less. In addition to fixed access, the fixed network sub-sector also includes core, transport- and transmission equipment.
+
+Further details are provided in Appendix IV.
+
+#### **10.1.3 Data centre**
+
+The data centre trajectory considers:
+
+- data traffic development in line with [b-Cisco] data forecast until 2022, extrapolated for 2025 and 2030;
+- power usage effectiveness (PUE) improvements (due to efficiency measures and cloudification), where cloudification and hyperscale data centres are the main reasons for efficiency improvements;
+- the typical server energy consumption is assumed to remain quite flat as capacity per unit increases;
+
+- a trend towards fewer and larger data centres;
+- edge computing mainly needed for low latency (gaming, high volumes for self-driving car which are not expected before 2030).
+
+Further details are provided in Appendix IV.
+
+#### 10.1.4 User equipment
+
+The user equipment trajectory considers the following.
+
+- Inclusion of customer premises equipment (CPE), fixed phones, personal computers (PCs) (including desktops, laptops, peripherals and displays), mobile devices (including mobile phones, smartphones, tablets), M2M (including smart meters, surveillance cameras, payment terminals, public displays, wearables).
+- Estimation of the number of devices in active use from sales statistics and estimated operational lifetime if relevant statistics are missing.
+- Regional distribution according to actual sales.
+- CPE: assumed energy efficiency improvements in line with business as usual (BAU).
+- Fixed phones: no energy efficiency improvements assumed.
+- PCs: lower share of desktops, energy efficiency improvements, gaming PCs small, but growing, share.
+- Mobile devices: larger share of smartphones, larger batteries (more power per device).
+- M2M: fast increase in the number of surveillance cameras until 2020, somewhat offset by energy efficiency improvements. Most M2Ms after 2020 are forecast to be wearables. Steady build-out of smart meters and payment terminals.
+
+Further details are provided in Appendix IV.
+
+#### 10.1.5 Enterprise networks
+
+The enterprise trajectory considers the following.
+
+- Enterprise networks; there was an increase in numbers to 2015. Increase might now be slower, since companies use their PCs for a longer time.
+- The small assumed increase in active local area network-personal computers (LAN-PCs), offset by energy efficiency improvements resulting in flat total energy.
+- The expectation that shipments stay roughly flat in line with [b-IDC] and [b-Gartner].
+
+Further details are provided in Appendix IV.
+
+## 10.2 Trajectories including electricity supply chain and grid losses (perspective A)
+
+This trajectory and its sub-trajectories represent the ICT footprint and a 1.5°C aligned trajectory for perspective A (see clause 1), which includes the ES chain and grid losses in line with LCA practice. Details on how these trajectories were derived are given in Appendix IV. For emission factors, see Table 1.
+
+#### 10.2.1 Global ICT sector trajectory (perspective A)
+
+The development of the ICT sector has been derived, with and without consideration of the development of the emission factor of the ES, and the resulting trajectory is outlined in Figure 3. The upper line shows the development of the sector before consideration of the decarbonization of the ES, and the lower line includes it, which is necessary for a 1.5°C trajectory. See Table 6.
+
+
+
+Overall footprint including electricity transmission and distribution losses and fuel supply chain
+
+Mt CO2 e
+
+2015 2020 2025 2030
+
+ICT's own development with unchanged electricity emission factor
+
+1.5°C trajectory
+
+L.1470(20)\_F03
+
+Line graph titled 'Overall footprint including electricity transmission and distribution losses and fuel supply chain'. The y-axis is 'Mt CO2e' from 0 to 1000. The x-axis is years from 2015 to 2030. Two lines are shown: a blue line for 'ICT's own development with unchanged electricity emission factor' and a green line for '1.5°C trajectory'. The blue line starts at 740 in 2015 and rises to 820 in 2030. The green line starts at 740 in 2015 and falls to 388 in 2030.
+
+**Figure 3 – ICT sector trajectory including electricity grid losses and supply chain (perspective A)**
+
+**Table 6 – ICT sector trajectory with electricity grid losses and supply chain included**
+
+| Total CO 2 e (Mt) | 2015 | 2020 | 2025 | 2030 |
+|-------------------------------------------------------|------------|------------|------------|------------|
+| Mobile networks | 115 | 109 | 92 | 70 |
+| Fixed networks | 67 | 59 | 42 | 27 |
+| Data centres | 141 | 127 | 104 | 79 |
+| User devices | 401 | 379 | 284 | 207 |
+| Enterprise networks | 16 | 14 | 8 | 5 |
+| Total including T&D losses and fuel supply | 740 | 687 | 530 | 388 |
+
+#### 10.2.2 Sub-sector trajectories (perspective A)
+
+This clause shows the different sub-sector trajectories for the trajectory in clause 10.2.1.
+
+For details, see Appendix IV.
+
+##### 10.2.2.1 Mobile network
+
+Figure 4 shows the resulting trajectory for mobile networks.
+
+
+
+Mobile networks
+
+Mt CO2 e
+
+2015 2020 2025 2030
+
+L.1470(20)\_F04
+
+Line graph titled 'Mobile networks'. The y-axis is 'Mt CO2e' from 0 to 200. The x-axis is years from 2015 to 2030. A single blue line shows a downward trend from 115 Mt CO2e in 2015 to 70 Mt CO2e in 2030.
+
+**Figure 4 – Mobile network trajectory including electricity grid losses and supply chain**
+
+##### 10.2.2.2 Fixed networks
+
+Figure 5 shows the resulting trajectory for fixed networks.
+
+
+
+A line graph titled "Fixed networks" showing the trajectory of Mt CO2 e from 2015 to 2030. The y-axis is labeled "Mt CO2 e" and ranges from 0 to 200 in increments of 20. The x-axis shows years: 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (65), 2020 (55), 2025 (45), and 2030 (30). The graph is labeled L.1470(20)\_F05.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 65 |
+| 2020 | 55 |
+| 2025 | 45 |
+| 2030 | 30 |
+
+Line graph titled 'Fixed networks' showing Mt CO2e trajectory from 2015 to 2030.
+
+Figure 5 – Fixed network trajectory including electricity grid losses and supply chain
+
+#### 10.2.2.3 Data centres
+
+Figure 6 shows the resulting trajectory for data centres.
+
+
+
+A line graph titled "Data centres" showing the trajectory of Mt CO2 e from 2015 to 2030. The y-axis is labeled "Mt CO2 e" and ranges from 0 to 200 in increments of 20. The x-axis shows years: 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (140), 2020 (125), 2025 (105), and 2030 (80). The graph is labeled L.1470(20)\_F06.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 140 |
+| 2020 | 125 |
+| 2025 | 105 |
+| 2030 | 80 |
+
+Line graph titled 'Data centres' showing Mt CO2e trajectory from 2015 to 2030.
+
+Figure 6 – Data centre trajectory including electricity grid losses and supply chain
+
+#### 10.2.2.4 User equipment
+
+Figure 7 shows the resulting trajectory for user devices.
+
+
+
+A line graph titled "User devices" showing the trajectory of Mt CO2 e from 2015 to 2030. The y-axis is labeled "Mt CO2 e" and ranges from 0 to 500 in increments of 50. The x-axis shows years: 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (400), 2020 (380), 2025 (280), and 2030 (210). The graph is labeled L.1470(20)\_F07.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 400 |
+| 2020 | 380 |
+| 2025 | 280 |
+| 2030 | 210 |
+
+Line graph titled 'User devices' showing Mt CO2e trajectory from 2015 to 2030.
+
+Figure 7 – End-user goods trajectory including electricity grid losses and supply chain
+
+#### 10.2.2.5 Enterprise networks
+
+Figure 8 shows the resulting trajectory for enterprise networks.
+
+
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 15 |
+| 2020 | 18 |
+| 2025 | 12 |
+| 2030 | 10 |
+
+Figure 8: Enterprise network trajectory including electricity grid losses and supply chain. A line graph showing Mt CO2e on the y-axis (0 to 200) against years on the x-axis (2015 to 2030). The trajectory starts at approximately 15 Mt CO2e in 2015, peaks at about 18 Mt CO2e in 2020, and then declines to about 10 Mt CO2e by 2030.
+
+Figure 8 – Enterprise network trajectory including electricity grid losses and supply chain
+
+## 10.3 Trajectories for the SBT initiative (perspective B)
+
+This trajectory and sub-trajectories (without grid ES chain and losses) represent the ICT footprint and 1.5°C aligned trajectory for perspective B (see clause 1), which excludes the ES chain and grid losses in line with company GHG emissions accounting practice. Details on how these trajectories were derived are given in Appendix IV. For emission factors, see Table 1.
+
+#### 10.3.1 Global ICT sector trajectory (perspective B)
+
+The development of the ICT sector has been derived with and without consideration of the development of the emission factor of the ES. The resulting trajectory is outlined in Figure 9. The blue line in Figure 9 shows the development of the sector before considering the decarbonization of the ES, and the green line includes the decarbonization of the electricity, which is necessary for a 1,5°C trajectory. See Table 7.
+
+
+
+| Year | ICT's own development (Mt CO 2 e) | 1.5°C trajectory (Mt CO 2 e) |
+|------|----------------------------------------------|-----------------------------------------|
+| 2015 | 620 | 620 |
+| 2020 | 650 | 580 |
+| 2025 | 680 | 450 |
+| 2030 | 700 | 320 |
+
+Figure 9: ICT sector trajectory excluding electricity grid losses and supply chain. A line graph showing Mt CO2e on the y-axis (0 to 1000) against years on the x-axis (2015 to 2030). Two lines are shown: a blue line for 'ICT's own development with unchanged electricity emission factor' and a green line for '1.5°C trajectory'. Both start at approximately 620 Mt CO2e in 2015. The blue line increases to about 700 Mt CO2e by 2030, while the green line decreases to about 320 Mt CO2e by 2030.
+
+Figure 9 – ICT sector trajectory excluding electricity grid losses and supply chain
+
+Table 7 – ICT sector trajectory excluding electricity grid losses and supply chain
+
+| Total CO 2 e (Mt) | 2015 | 2020 | 2025 | 2030 |
+|-------------------------------------------------------|------------|------------|------------|------------|
+| Mobile networks | 98 | 94 | 79 | 59 |
+| Fixed networks | 55 | 49 | 35 | 22 |
+| Data centres | 116 | 104 | 84 | 60 |
+| User devices | 335 | 317 | 241 | 174 |
+| Enterprise networks | 13 | 12 | 6 | 4 |
+| Total excluding T&D losses and fuel supply | 617 | 576 | 445 | 319 |
+
+##### 10.3.1.1 Mobile networks
+
+Figure 10 shows the resulting trajectory for mobile networks.
+
+
+
+A line graph titled "Mobile networks" showing the trajectory of emissions in Mt CO2 e from 2015 to 2030. The y-axis ranges from 0 to 200 Mt CO2 e in increments of 20. The x-axis shows the years 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (100 Mt CO2 e), 2020 (95 Mt CO2 e), 2025 (80 Mt CO2 e), and 2030 (60 Mt CO2 e). The graph is labeled L.1470(20)\_F10.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 100 |
+| 2020 | 95 |
+| 2025 | 80 |
+| 2030 | 60 |
+
+Line graph titled 'Mobile networks' showing a downward trend in Mt CO2e from 2015 to 2030.
+
+**Figure 10 – Mobile network excluding electricity grid losses and supply chain**
+
+##### 10.3.1.2 Fixed networks
+
+Figure 11 shows the resulting trajectory for fixed networks.
+
+
+
+A line graph titled "Fixed networks" showing the trajectory of emissions in Mt CO2 e from 2015 to 2030. The y-axis ranges from 0 to 200 Mt CO2 e in increments of 20. The x-axis shows the years 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (55 Mt CO2 e), 2020 (50 Mt CO2 e), 2025 (40 Mt CO2 e), and 2030 (20 Mt CO2 e). The graph is labeled L.1470(20)\_F11.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 55 |
+| 2020 | 50 |
+| 2025 | 40 |
+| 2030 | 20 |
+
+Line graph titled 'Fixed networks' showing a downward trend in Mt CO2e from 2015 to 2030.
+
+**Figure 11 – Fixed networks trajectory excluding electricity grid losses and supply chain**
+
+#### 10.3.1.3 Data centres
+
+Figure 12 shows the resulting trajectory for data centres.
+
+
+
+A line graph titled "Data centres" showing the trajectory of emissions in Mt CO2 e from 2015 to 2030. The y-axis ranges from 0 to 200 Mt CO2 e in increments of 20. The x-axis shows the years 2015, 2020, 2025, and 2030. The data points are approximately: 2015 (115 Mt CO2 e), 2020 (105 Mt CO2 e), 2025 (85 Mt CO2 e), and 2030 (60 Mt CO2 e). The graph is labeled L.1470(20)\_F12.
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 115 |
+| 2020 | 105 |
+| 2025 | 85 |
+| 2030 | 60 |
+
+Line graph titled 'Data centres' showing a downward trend in Mt CO2e from 2015 to 2030.
+
+**Figure 12 – Data centre trajectory excluding electricity grid losses and supply chain**
+
+#### 10.3.1.4 User equipment
+
+Figure 13 shows the resulting trajectory for user devices.
+
+
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 340 |
+| 2020 | 320 |
+| 2025 | 240 |
+| 2030 | 180 |
+
+L.1470(20)\_F13
+
+Line graph titled 'User devices' showing a downward trend in Mt CO2e from 2015 to 2030. The y-axis ranges from 0 to 500 Mt CO2e in increments of 50. The x-axis shows years from 2015 to 2030. The data points are approximately: 2015 (340), 2020 (320), 2025 (240), and 2030 (180).
+
+**Figure 13 – End-user goods trajectory excluding electricity grid losses and supply chain**
+
+##### 10.3.1.5 Enterprise networks
+
+Figure 14 shows the resulting trajectory for enterprise networks.
+
+
+
+| Year | Mt CO 2 e |
+|------|----------------------|
+| 2015 | 15 |
+| 2020 | 14 |
+| 2025 | 13 |
+| 2030 | 12 |
+
+L.1470(20)\_F14
+
+Line graph titled 'Enterprise networks' showing a nearly flat, slightly downward trend in Mt CO2e from 2015 to 2030. The y-axis ranges from 0 to 200 Mt CO2e in increments of 20. The x-axis shows years from 2015 to 2030. The data points are approximately: 2015 (15), 2020 (14), 2025 (13), and 2030 (12).
+
+**Figure 14 – Enterprise networks trajectory excluding electricity grid losses and supply chain**
+
+### 10.4 Comparison of the SBT initiative trajectory with normative limits
+
+Annex A uses the electricity budget approach to investigate whether the ICT trajectory outlined in clause 10 and Appendix IV respects the limits emerging from the normative scenarios in clause 9.
+
+Annex A first calculates the electricity development trajectory 2015–2030 for energy-related emissions for usage and manufacturing, to ensure that the trajectory does not increase its share of the overall electricity budget. The overall GHG emissions of the sector are then calculated as the product of the overall electricity consumption and the emission factor derived by the SBT initiative, plus non-electricity-related emissions. The total GHG emission level derived is then compared with the minimum reduction levels put forward in the other normative approaches in clauses 9.1 and 9.2. The analysis shows that the scenario put forward in clause 10 falls within the normative boundaries and can form the basis for future company level guidance.
+
+# 11 Opportunities and risks for the ICT sector to attain the 1.5°C trajectory
+
+## 11.1 Introduction
+
+Figure 15 illustrates how the ICT trajectories have been developed.
+
+
+
+The graph, titled 'Sub-sector pathway (Global GHG emissions)', plots 'Global GHG emissions' on the y-axis against years from 2018 to 2032 on the x-axis. Three lines originate from a common point in 2020. The grey line ('Trajectory excluding ICT efficiency improvements') rises slightly to 2030. The orange line ('Trajectory with fixed grid C intensity') follows the grey line until 2030, then drops. The blue line ('Trajectory with electricity emission factor in line with SBTi 1.5°C grid decarbonization rate') drops steadily from 2020 to 2032.
+
+| Year | Trajectory excluding ICT efficiency improvements | Trajectory with fixed grid C intensity | Trajectory with electricity emission factor in line with SBTi 1.5°C grid decarbonization rate |
+|------|--------------------------------------------------|----------------------------------------|-----------------------------------------------------------------------------------------------|
+| 2018 | Baseline | Baseline | Baseline |
+| 2020 | Baseline | Baseline | Baseline |
+| 2022 | Increasing | Increasing | Decreasing |
+| 2024 | Increasing | Increasing | Decreasing |
+| 2026 | Increasing | Increasing | Decreasing |
+| 2028 | Increasing | Increasing | Decreasing |
+| 2030 | Peak | Peak | Decreasing |
+| 2032 | N/A | Decreasing | Decreasing |
+
+L.1470(20)\_F15
+
+Figure 15: Trajectory development graph showing Global GHG emissions from 2018 to 2032. The graph displays three sub-sector pathways: 'Trajectory excluding ICT efficiency improvements' (grey line), 'Trajectory with fixed grid C intensity' (orange line), and 'Trajectory with electricity emission factor in line with SBTi 1.5°C grid decarbonization rate' (blue line). The blue line shows a significant decrease in emissions over time, while the other two lines show a slight increase or stability.
+
+**Figure 15 – Trajectory development**
+
+NOTE – Figure 15 is intended to illustrate the various principal parameters that impact a trajectory over time. The intention is not to outline the actual relationship between those parameters.
+
+The lowest line represents the trajectories described in clause 10. In this case, the power sector is expected to decarbonize in line with a 1.5°C scenario and the ICT industry is expected to continue to introduce significant energy efficiency measures in its products and operations. The middle and uppermost lines represent worse case situations. The middle line shows what happens if the power sector fails to decarbonize and the ICT sector fail to mitigate that through purchase or investment in renewables. The uppermost line shows what could happen if the ICT sector does not make any electricity efficiency improvements.
+
+The risks in clause 11.3 describe these unwelcome outcomes in more detail, whilst the opportunities in clause 11.3 describe actions the ICT sector can take to mitigate the risks and maintain the desired trajectory.
+
+## 11.2 Opportunities – strategies to decarbonize the ICT sector until 2030
+
+A number of actors in the ICT sector have made significant efforts to decarbonize their activities during the period 2010–2019. The efforts made were mainly relative to energy efficiency measures and switch to renewable ES.
+
+Compared to BAU, these efforts brought reduced GHG emissions, reduced electricity consumption, financial savings and less dependency on the evolution of the price of grid electricity.
+
+For the period 2020–2030, the main strategy to decarbonize the ICT sector, at the pace necessary to align with 1.5°C trajectories, seems to be the implementation of simultaneous, vigorous and urgent actions in the following fields:
+
+- implementation of energy efficiency plans;
+- switch to renewable or low carbon electricity supplies;
+- encouragement of carbon consciousness among end-users.
+
+Figure 16 shows some examples of categories of supporting actions.
+
+Further guidance on how ICT sector decarbonization is expected to be provided in the Guidance for organizations document.
+
+#### CATEGORIES:
+
+#### OPERATING ENERGY-EFFICIENT NETWORK
+
+1. Multiple power saving features
+2. Alternative energy supply
+3. Consolidation and virtualization
+4. Free cooling and location optimization
+
+#### EFFICIENCY IN BUILDINGS AND SERVICES
+
+5. Monitoring solutions for efficient buildings
+6. Focus on energy conservation measures
+7. Alternative mobility concepts
+8. Videoconferencing and audioconferencing
+
+#### ALTERNATIVE ENERGY
+
+9. Self-production of renewable energies
+10. Purchasing renewable energy the certificate of origin and PPA
+11. Energy supply innovation
+
+#### APPLICATION OF THE CIRCULAR ECONOMY PRINCIPLES
+
+12. Eco-design of products and services
+13. Reuse of network equipment
+14. Optimizing the life cycle and end-of-life of customer products and services
+15. Selling repairable products
+
+L.1470(20)\_F16
+
+**Figure 16 – Decarbonization measures** [source: Orange, with permission]
+
+#### Operating energy-efficient networks
+
+The network infrastructure forms the basis of ICT products and services. Achieving greater energy efficiency in network operation is a key component to decarbonize the sector.
+
+The adoption of standards, e.g., Recommendations developed by ITU-T SG5: [b-ITU-T L.1300]; [b-ITU-T L.1301]; [b-ITU-T L.1302]; [b-ITU-T L.1303]; [b-ITU-T L.1310]; [b-ITU-T L.1315]; [b-ITU-T L.1320]; [b-ITU-T L.1321]; [b-ITU-T L.1325]; [b-ITU-T L.1330]; [b-ITU-T L.1331]; [b-ITU-T L.1332]; [b-ITU-T L.1340]; [b-ITU-T L.1350]; [b-ITU-T L.1351]; [b-ITU-T L.1360]; [b-ITU-T L.1361]; [b-ITU-T L.1362]; and [b-ITU-T L.1370], provides guidance for the implementation of energy-efficient networks and data centres.
+
+##### 1 Multiple power saving features
+
+The traffic load of the networks, in particular mobile networks, vary significantly throughout the day. Power-saving features, e.g., dynamic power allocation or active antennas, can reduce the energy consumption of networks when the load is lower.
+
+##### 2 Alternative energy supply
+
+The usage of 400 V direct current (DC) for power supply may bring significant improvements in terms of energy consumption. Another example of action is the implementation of combined heat and power (CHP) plants.
+
+The following Recommendations, developed by ITU-T SG5: [b-ITU-T L.1200]; [b-ITU-T L.1201]; [b-ITU-T L.1202]; [b-ITU-T L.1203]; [b-ITU-T L.1204]; [b-ITU-T L.1205]; [b-ITU-T L.1206]; and [b-ITU-T L.1207], provide guidance on the implementation of 400 V DC for ICT operations.
+
+##### 3 Consolidation and virtualization
+
+Consolidation of data centres: regrouping physical servers in an optimized unique location; virtualization of servers; and bringing several virtual software servers on a single physical server, brings significant reductions in terms of electricity consumption and GHG emissions.
+
+More generally, data centre virtualization encompasses a broad range of tools, technologies and processes that enable a data centre to operate and provide services with reduced energy consumption.
+
+##### 4 Free cooling and location optimization
+
+Fresh air-conditioning systems use air outside when it is cooler than that inside a building, even during hot weather. They bring significant energy consumption reductions compared to conventional air-conditioning systems.
+
+Adiabatic cooling may be operated in hot climates. Water is sprayed into the air before entering the existing free cooling system. As the water evaporates, the air is chilled.
+
+Location optimization, in geographic areas where the temperature is relatively low throughout the year, is an efficient way to reduce electricity consumption and GHG emissions.
+
+#### **Efficiency in buildings and services**
+
+Tertiary buildings and mobility services account for a part of the energy consumption of ICT actors and thus their CO2 emissions. Opportunities to optimize the energy performance and reduce the environmental impact of these assets are being seized by many actors in the world.
+
+##### **5 Monitoring solution for efficient buildings**
+
+Building management systems that control and monitor a building's mechanical and electrical equipment, e.g., ventilation, lighting, power systems and security systems, potentially using artificial intelligence, enable efficient energy management worldwide.
+
+##### **6 Focus on energy conservation measures**
+
+Installation of energy conservation measures, e.g., new energy-efficient ceiling lighting, adapted heating systems, presence detectors and variable light controls to adjust the lighting required, are the basis for achieving efficiency in buildings.
+
+##### **7 Alternative mobility concepts**
+
+Inside ICT organizations, usage of electric and hybrid vehicles, shared fleets, automated vehicle maintenance alerts and global positioning system (GPS) routing bring significant benefits.
+
+Encouraging fuel-efficient driving through driver training courses also brings benefits.
+
+##### **8 Videoconferencing and audioconferencing**
+
+Videoconferencing and audioconferencing solutions allow, under specific conditions, carbon emissions associated with business travel and daily commuting to be reduced.
+
+#### **Alternative energy supply**
+
+##### **9 Self-production of renewable energies**
+
+Installation of on-site renewable sources when it is feasible brings significant benefits, e.g., when installing solar photovoltaic systems on base station sites, data centres and technology centres.
+
+##### **10 Purchasing renewable energy with the certificate of origin and PPA**
+
+In order to mitigate GHG emissions associated with electricity usage, ICT actors can increase energy procurement from renewable sources, purchasing renewable energy certificates (RECs) that respect additionality principles or using power purchase agreements (PPAs).
+
+##### **11 Energy supply innovation**
+
+Many research initiatives are arising in the field of energy supply alternatives, including hydrogen fuel cell systems.
+
+The development of new technologies to store energy and of decentralized energy storage are expected to bring additional benefits.
+
+Moreover, to support renewable energy use at all stages of the ICT value chain represents an opportunity to reduce significantly the total ICT sector footprint.
+
+The following Recommendations, developed by ITU-T SG5: [b-ITU-T L.1220]; [b-ITU-T L.1221]; and [b-ITU-T L.1222], provide guidance relative to innovative energy storage technology for stationary use.
+
+#### Application of circular economy to products and services
+
+The eco-conception of product and services, the reuse of network and customer equipment, the optimization of the life cycle of customer products, including the selling of repairable products, bring a positive impact on energy consumption and GHG emissions.
+
+The following Recommendations, developed by ITU-T SG5: [b-ITU-T L.1020]; [b-ITU-T L.1021]; and [b-ITU-T L.1022], provide guidelines for ICT operators and suppliers to implement circular economy principles in the ICT sector.
+
+The following Recommendations, developed by ITU-T SG5: [b-ITU-T L.1000]; [b-ITU-T L.1001]; [b-ITU-T L.1006]; and [b-ITU-T L.1007], provide details and test suites related to an external universal power adaptor.
+
+[b-ITU-T L.1010], developed by ITU-T SG5, provides green battery solutions for mobile phones and other hand-held ICT equipment.
+
+[b-ITU-T L.1015], developed by ITU-T SG5, provides criteria for the evaluation of the environmental impact of mobile phone and may be used in the framework of eco-conception approaches.
+
+[b-ITU-T L.1410], developed by ITU-T SG5 in cooperation with the Environmental Engineering technical committee of the European Telecommunications Standards Institute (EE-ETSI), provides methodology for the environmental LCA of ICT goods, networks and services that can be used in the framework of eco-conception approaches.
+
+## 11.3 Risks
+
+The decarbonization of the ICT sector is, to a high extent, dependent on the availability of low carbon electricity that has been a precondition for the main scenarios. Renewables could be made available through decarbonization of the electricity grid, additional purchase of renewables and through the sector's investment in own electricity sources. [b-Andrae 2015], [b-Andrae 2019a] and [b-Andrae 2019b] estimate how the ICT sector power footprint could evolve under certain circumstances, i.e., if the power sector (as in the past) does not live up to what is needed under [b-UNFCCC PA] and [b-IPCC 1.5] and if the ICT sector fails to mitigate that through purchase of renewables and its own ES.
+
+Appendix V outlines the importance of the availability of renewables and of continued energy performance improvements for the ICT sector to decarbonize.
+
+For the grid development to be in line with the SBT initiative 1.5°C scenario, it is estimated based on [b-IEA ETP 2017] and [b-IEA 2019] that 55% of current overall fossil electricity production, as well as any additional use of grid electricity, need to be replaced by low-carbon alternatives. Put differently, the SBT initiative grid scenario demands that, by 2030, there needs to be enough renewable electricity to equal the overall electricity production in the world. However, the ICT sector's opportunity to use renewables goes beyond the average grid development, due to opportunities to preferentially purchase or invest in renewables beyond this average.
+
+A further risk is that the ICT sector activity growth to efficiency ratio is greater than predicted in the modelling. This would lead to an increase in projected GHG emissions relative to the absolute pathways. This can happen, either as a result of higher than expected growth or lower than expected efficiency improvements.
+
+Efficiency improvements are a key lever the ICT industry has at its disposal and it is therefore critical that the efficiency of ICT productivity remain a strong focus alongside the installation and procurement of renewable electricity.
+
+# Annex A
+
+## Analysis of ICT sector and sub-sectors trajectories
+
+(This annex forms an integral part of this Recommendation.)
+
+This annex investigates whether the ICT trajectory from clause 10 and Appendix IV falls within the limits defined by the normative approach outlined in clause 9. Table A.1 shows that the trajectory from clause 10 respects both the electricity budget and the GHG emissions budgets as outlined in clauses 9.1 to 9.3. Thus, the trajectory shows a way for the ICT sector to align with a 1.5°C trajectory and confirms that an ambition level in accordance with the normative approach seems feasible. However, it should be noted that the actual decarbonization of the ICT sector may take different paths, as long as the normative limits and the ambition level are respected.
+
+This analysis includes emissions related to all life cycle stages, i.e., it includes emissions that belong to the ICT footprint, but which occur outside the ICT sector.
+
+Table A.1
+
+| | Electricity (TWh) | | | | Electricity-related CO 2 e emissions (excluding electricity supply chain and grid losses) (Mt CO 2 e) | | | | Non-electricity emissions (Mt CO 2 e) | | | |
+|-----------------------------------------------------------------------------------|-------------------|--------|--------|--------|--------------------------------------------------------------------------------------------------------------------------------------|------|------|------|--------------------------------------------------|------|------|------|
+| | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 |
+| Energy-sector development (electricity budget) | | | | | | | | | | | | |
+| 1.5°C grid emission factors 2015–2020: Actual; 2025–2030 SBT initiative | 0.484 | 0.480 | 0.281 | 0.160 | | | | | | | | |
+| Reduction in emission factor from 2015 value (%) | | | 42 | 67 | | | | | | | | |
+| [b-IEA ETP 2017] 1.5°C scenario (estimate) global electricity generation (TWh) | 24 185 | 26 013 | 27 841 | 30 478 | | | | | | | | |
+| Increase in energy generation from 2015 (%) | | 8 | 15 | 26 | | | | | | | | |
+| Reduction in energy sector emissions between 2015 and 2031 (%) | | | | 58 | | | | | | | | |
+| Operation/usage related emissions | | | | | | | | | | | | |
+| Mobile networks | | | | | | | | | | | | |
+| Mobile network operator overheads – electricity (s2) | 13 | 13 | 17 | 20 | 6.4 | 6.4 | 4.8 | 3.2 | | | | |
+| Mobile network operator overheads – excluding electricity | | | | | | | | | 4 | 3.8 | 2.7 | 1.2 |
+| Mobile network own electricity generation | 27 | 25 | 23 | 19 | 25 | 23 | 21 | 18 | | | | |
+
+| | Electricity (TWh) | | | | Electricity-related CO 2e emissions (excluding electricity supply chain and grid losses) (Mt CO 2e ) | | | | Non-electricity emissions (Mt CO 2e ) | | | |
+|---------------------------------------------------------------------------|-------------------|------------|------------|------------|-------------------------------------------------------------------------------------------------------------------------------------|-------|-------|-----------|--------------------------------------------------|-------|-------|-----------|
+| | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 |
+| Mobile network electricity consumption | 90 | 115 | 125 | 131 | 48 | 46 | 35 | 21 | | | | |
+| Mobile: own + grid + overheads electricity | 130 | 153 | 164 | 171 | | | | | | | | |
+| Change on 2015 (%) | | | 26 | 31 | | | | | | | | |
+| Fixed networks | | | | | | | | | | | | |
+| Fixed network operator overheads – electricity | 7 | 7 | 9 | 10 | 3.2 | 3.2 | 2.4 | 1.6 | | | | |
+| Fixed network operator overheads – excluding electricity | | | | | | | | | 2 | 1.9 | 1.4 | 0.6 |
+| Fixed network electricity consumption (s2) | 85 | 100 | 89 | 88 | 43 | 38 | 25 | 14 | | | | |
+| Fixed: grid + overheads electricity | 92.0 | 106.7 | 97.5 | 97.5 | | | | | | | | |
+| Change on 2015 (%) | | | 5 | 3 | | | | | | | | |
+| Data centres | | | | | | | | | | | | |
+| Data centre operator overheads (electricity) | 15 | 15 | 20 | 20 | 6.4 | 7.2 | 5.6 | 3.2 | | | | |
+| Data centre operator overheads (excluding electricity) | | | | | | | | | 3 | 2.8 | 2.1 | 0.9 |
+| Data centre electricity consumption | 205 | 215 | 235 | 257 | 91.2 | 84 | 60 | 40 | | | | |
+| Date centre: grid + overheads electricity | 220 | 230 | 254.93 | 277.00 | | | | | | | | |
+| Change on 2015 (%) | | | 15 | 25 | | | | | | | | |
+| User devices | | | | | | | | | | | | |
+| User device operation (s3) | 345 | 335 | 409 | 450 | 169 | 161 | 115 | 72 | | | | |
+| Change on 2015 (%) | | | 19 | 30 | | | | | | | | |
+| ICT Operating electricity consumption (excluding user devices) | 442 | 490 | 517 | 545 | | | | | | | | |
+| Increase from 2015 (%) | | | 17 | 23 | | | | | | | | |
+| ICT operating electricity consumption (including user devices) | 787 | 825 | 926 | 995 | | | | | | | | |
+| Increase from 2015 (%) | | | 18 | 26 | | | | | | | | |
+| ICT usage share of global electricity generation (%) | 3.3 | 3.2 | 3.3 | 3.3 | | | | | | | | |
+| Usage-related to total CO2 (Mt) | 393.2 | 407.3 | 274.8 | 174.12 | 392.2 | 368.8 | 268.8 | 173 | 401.2 | 377.3 | 275.0 | 175.7 |
+| Reduction in ICT usage-related emissions between 2015 and 2030 (%) | | | | | | | | 56 | | | | 56 |
+| Embodied emissions | | | | | | | | | | | | |
+| Mobile networks | | | | | | | | | | | | |
+| Mobile manufacturing excluding electricity (s1) | | | | | | | | | 9 | 9 | 9 | 9 |
+| Mobile manufacturing electricity (s2) | 5 | 11.88 | 17.08 | 25.00 | 6 | 5.7 | 4.8 | 4 | | | | |
+| Change on 2015 (%) | | | 242 | 400 | | | | | | | | |
+| Fixed networks | | | | | | | | | | | | |
+| Fixed manufacturing – excluding electricity | | | | | | | | | 4.5 | 3.75 | 3.4 | 3 |
+| Fixed manufacturing – electricity | 1.7 | 4.48 | 6.05 | 8.31 | 2.5 | 2.15 | 1.7 | 1.33 | | | | |
+| Change on 2015 (%) | | | 256 | 389 | | | | | | | | |
+
+| | Electricity (TWh) | | | | Electricity-related CO 2e emissions (excluding electricity supply chain and grid losses) (Mt CO 2e ) | | | | Non-electricity emissions (Mt CO 2e ) | | | |
+|---------------------------------------------------------------------------------------------------------|-------------------|--------|--------|--------|-------------------------------------------------------------------------------------------------------------------------------------|------|------|------|--------------------------------------------------|-------|------|------|
+| | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 | 2015 | 2020 | 2025 | 2030 |
+| Data centres | | | | | | | | | | | | |
+| Data centre manufacturers excluding electricity | | | | | | | | | 9 | 9.4 | 9.75 | 9.75 |
+| Data centre manufacturers electricity | 5 | 13.13 | 19.04 | 27.81 | 6 | 6.3 | 5.35 | 4.45 | | | | |
+| Change on 2015 (%) | | | 281 | 456 | | | | | | | | |
+| User devices | | | | | | | | | | | | |
+| User devices manufacturers excluding Electricity | | | | | | | | | 35 | 35 | 35 | 35 |
+| User devices manufacturers electricity | 149 | 133.33 | 145.91 | 143.75 | 70 | 64 | 41 | 23 | | | | |
+| Change on 2015 (%) | | | -2 | -4 | | 86 | 52 | 32 | | 70 | 70 | 70 |
+| ICT Manufacturers electricity consumption | 159 | 163 | 188 | 205 | | | | | | | | |
+| Increase from 2015 (%) | | | 18% | 29% | | | | | | | | |
+| ICT manufacturing share of global electricity generation | 0.7% | 0.6% | 0.7% | 0.7% | | | | | | | | |
+| Total manufacturing-related CO2 (Mt) | 77.0 | 78.2 | 52.9 | 32.8 | 84.5 | 78.2 | 52.9 | 32.8 | 134.52 | 135.3 | 110 | 89.5 |
+| Reduction in ICT sector manufacturing-related emissions between 2015 and 2030 (%) | | | | | | | | 61 | | | | 33 |
+| Total electricity-related emissions | | | | | | | | | | | | |
+| Electricity-related total sector emissions | 470.2 | 485.4 | 327.7 | 206.9 | | | | | | | | |
+| Reduction in ICT sector emissions between 2015 and 2030 (%) | | | | 56 | | | | | | | | |
+| Reduction in Power sector emissions between 2015 and 2031 (%) | | | | 58 | | | | | | | | |
+| ICT share of global electricity generation (%) | 3.9 | 3.8 | 4.0 | 3.9 | This is within the normative limit for ICT electricity usage based on IEA | | | | | | | |
+| Total emissions | | | | | | | | | | | | |
+| ICT sector total CO2 (Mt) including electricity and non-electricity-related emissions | 604.7 | 620.7 | 437.7 | 296.4 | | | | | | | | |
+| Reduction in ICT sector emissions between 2015 and 2030 | | | | 51% | This is within the normative limit for ICT GHG emissions both for the SBT initiative and IPCC P2 | | | | | | | |
+| NOTE – All values exclude electricity transmission, distribution and supply chain related emissions | | | | | | | | | | | | |
+
+**Electricity (TWh):** 2015 figures from baseline of this Recommendation; 2025 and 2030 figures reverse calculated from Appendix V CO2 numbers using the SBT initiative grid intensities.
+
+**Electricity-related CO2e emissions:** (excluding electricity supply chain and grid losses) (Mt CO2e ) taken from Table IV.2.
+
+**Non-electricity emissions (Mt CO2e ) for operation** are decreasing in line with electricity emission reductions. Note that data sources do not often provide explicit information regarding distribution between electricity and non-electricity based emissions (This calculation assumes 25% of supply chain emissions to be electricity based.)
+
+## Appendix I
+
+### Introduction to the Science-Based Targets initiative framework
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes some implications for the development of ICT sector and ICT sub-sector from the SBT initiative framework. The full framework is available in [b-SBT Methods].
+
+The normal sectoral decarbonization approach (SDA) is a method for setting physical emissions intensity targets that uses convergence. An emissions intensity target is specified by a reduction in emissions relative to a specific business metric, such as production output of a company, (e.g., tonne CO2e per tonne product produced). The SDA assumes global convergence of the emissions intensity of key sectors by 2050.
+
+The most common SDA at this point uses the B2DS scenario from [b-IEA ETP 2017], which comprises emissions and activity projections used to compute sectoral pathways aligned with limiting warming to well below 2°C.
+
+Due to the lack of 1.5°C scenario data from IEA, the SBT initiative currently does not provide an SDA option for 1.5°C targets. Additionally, regional pathways have not been incorporated into the SDA method.
+
+### I.1 Applying the SDA to ICT
+
+Currently, the ETP scenarios have no direct reference to the ICT sector, which means the current SDA tool of the SBT initiative excludes any reference to ICT.
+
+[b-SBT Manual] places the manufacture of computer, electronic, optical and electrical equipment products in the "all other industry" category and recommends this ICT sub-sector to set an absolute or emissions intensity target in line with the absolute contraction approach.
+
+In order to improve the usability of SDA, it is important to consider the situation of companies in different key sub-sectors of the ICT sector: ICT end-user equipment; telecommunication networks (fixed line and mobile); data centres including cloud operators and the ICT service sector.
+
+### I.2 Initial boundary conditions
+
+Emissions associated with the use of ICT equipment currently amount to approximately 60% of the total life cycle carbon footprint of the sector, with the remaining footprint split roughly equally between electricity consumption in manufacture, and all other emissions including diesel generators, embedded carbon in materials and components, transport and fugitive emissions.
+
+The main focus of this appendix is therefore on modelling an SDA pathway for the dominant component of the ICT total carbon footprint, namely the energy consumed during the use phase of ICT equipment.
+
+### I.3 Establishing an ICT sub-sector pathway
+
+Sectoral SDA pathways project existing sector baseline data into the future. This requires an evaluation as to how the sector will grow and become more efficient. According to the SDA methodology, a sector's growth is measured using an appropriate activity metric that is well related to its energy consumption and consequential CO2 emissions. In the case of the power sector, activity levels are measured by the number of megawatt hours of electricity generation in a given year. For commercial buildings, it is the floor area in square metres of real estate for a given year.
+
+It is considered very unlikely that there will be a single form of activity metric relevant to all ICT sub-sectors. For this reason, a sub-sector approach has been adopted. Once a suitable activity metric
+
+has been selected, then an ICT sub-sector pathway associated with use phase electricity can be developed using Equation 1:
+
+$$SC_{s,y} = SA_{s,y} \cdot SE_{s,y} \cdot PI_y \quad (1)$$
+
+where
+
+- $SA_{s,y}$ is the activity in year $y$ (activity units) for ICT sub-sectors;
+- $SE_{s,y}$ is the energy intensity in year $y$ (MWh/activity) for ICT sub-sectors;
+- $PI_y$ is the carbon intensity for the power sector in year $y$ (tCO2 /MWh);
+- $SC_{s,y}$ is the total of carbon emissions in year $y$ (tCO2 ).
+
+This approach follows recommendation R8 of [b-SBT Criteria] that highlights the need to consider both efficiency improvements (addressed by $SE_{s,y}$ ) as well as any carbon reductions delivered by the power sector (sourced from the [b-IEA ETP 2017] data and addressed by $PI_y$ ).
+
+NOTE – In the case of the mobile sector, Equation 1 is modified to take account of the considerable amount of on-site, diesel-generated electricity present in some geographies as discussed in Appendix IV.
+
+### I.4 Absolute versus SDA
+
+According to the [b-SBT Manual], the minimum reduction required for absolute targets in line with well-below 2°C scenarios is 2.5% in annual linear terms. However, companies, particularly those in developed countries, are strongly encouraged to adopt targets with a 4.2% annual linear reduction to be aligned with limiting warming to 1.5°C.
+
+The IEA currently does not offer ETP pathways for a 1.5°C scenario and so to date the SDA tool of the SBT initiative has relied on the [b-IEA ETP 2017] B2DS pathways (equivalent to an alignment with a 1.75°C global temperature rise).
+
+The SBT initiative has recently shared a provisional draft 1.5°C pathway for the power sector and this has been included in this Recommendation.
+
+### I.5 Power sector carbon emission intensity
+
+#### I.5.1 Compatibility with scope 2 GHGP reporting
+
+A company needs to establish two sets of SBTs. One for its combined scope 1 and 2 emissions, and another for its scope 3 emissions. To ensure consistency between the sector pathways and corporate carbon accounting standards, it is therefore important to ensure that figures for the carbon intensity of the power sector used to establish sub-sector pathways follow the GHGP guidance.
+
+P. 87 of Appendix A of [b-GHG P] states:
+
+Emissions associated with the extraction and production of fuels consumed in the generation of purchased electricity may be reported in scope 3 under the category "extraction, production, and transportation of fuels consumed in the generation of electricity." ... Emissions from the generation of electricity that is consumed in a T&D system may be reported in scope 3 under the category "generation of electricity that is consumed in a T&D system" by end-users. ... Consistent with the scope 2 definition ..., the *GHG Protocol Corporate Standard* requires the use of EFG [emission factor at generation] to calculate scope 2 emissions.
+
+The calculations intended for any ICT pathways that will be used for scope 1 and 2 SBTs should therefore use power sector carbon intensities based on generation and exclude T&D losses.
+
+## Appendix II
+
+### Opportunities for the ICT sector to help decarbonize other sectors
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The focus of this Recommendation is to derive a trajectory for the ICT sector that supports a 1.5°C limitation of climate change and the responsibility of the ICT footprint clearly lies within the sector. However, while striving to implement the decarbonization trajectory, it is important to understand that ICT, unlike many products and services sold in the world today, distinguishes itself by its double-edged nature. On the one hand, ICTs have an environmental impact at each stage of their life cycle, from energy and natural resource consumption to e-waste. On the other, ICTs can enable vast efficiencies in lifestyle and in all sectors of the economy through the provision of digital solutions that can improve energy efficiency, inventory management and business efficiency by reducing travel and transportation, e.g., teleworking and videoconferencing and by substituting physical products for digital information. The latter capacity is referred to collectively as second order or enablement effects.
+
+Beyond this, ICT has effects at the societal level by reshaping how people lead their lives. Such effects are much larger than the footprint itself and are important aspects to consider when optimizing the overall decarbonization of society.
+
+Some examples of the wider impacts of the ICT sector include, *inter alia*:
+
+- virtual services replacing physical products, e.g., using e-readers instead of paperback books, optimizing entire sectors, like transport, industry, and agriculture;
+- ICT can foster new sustainable lifestyles;
+- significant improvement through digital services in the utilization of resources, e.g., infrastructure, vehicles and buildings.
+
+Concretely this means e.g.,
+
+- IoT-enabled building energy management systems;
+- smart irrigation;
+- energy-efficient frozen food;
+- managing urban traffic flow and congestion;
+- intelligent lighting;
+- intersection safety analytics;
+- intelligent traffic management.
+
+The underlying idea is that global GHG emissions can be significantly reduced if existing and developing ICT solutions are used in other sectors (and ICT itself) to leverage their full potential in a smart manner.
+
+The positive contribution of assessed services based on ICT has been found to increase its direct footprint by an order of magnitude. However, such gains could be offset by rebound effects and even by other services optimized for other purposes (such as oil extraction). ICT has great potential, but as a common-purpose tool, it could be used for different purposes. Directed towards decarbonization, its enablement effect is perhaps yet unleashed.
+
+## Appendix III
+
+### Baseline values – Energy consumption and carbon footprints
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This baseline is defined in accordance with [b-Malmodin 2018a] and [b-Malmodin 2018c]. The method and main data sources are summarized here. Further details are given in [b-Malmodin 2018a] and [b-Malmodin 2018b].
+
+### III.1 Summary
+
+The ICT sector is divided into the three main sub-sectors: end user goods (user devices); networks (including both mobile and fixed); and data centres, including enterprise networks. A large amount of primary data has been collected directly from ICT and entertainment and media (E&M) companies. In total, data from about 100 of the world's largest manufacturers, operators, as well as ICT and E&M service companies have been collected [b-Malmodin 2018a]. ICT companies that cover about 40% of all mobile subscriptions and about 15% of all fixed subscriptions, including about 15% of final estimated electricity consumption in data centres have reported their data. See Figure III.1.
+
+
+
+The diagram illustrates the ICT sector's structure, centered around the **Global Internet** (represented by a globe). Four main sub-sectors are shown, each connected to the central internet:
+
+- User equipment:** Located on the left, it includes icons for Older phones, Fixed cordless phones, Mobile phones, smartphones and tablets, Routers, modems CPE (Customer premises equipment), Desktop and laptop PCs, Public displays, and NEW! Connected devices.
+- Access networks:** Located at the top left, it includes Fixed telephony networks, Mobile networks, and Fixed broadband networks.
+- Operator activities:** Located at the top right, it includes Control and core nodes, Offices and stores travel and vehicles, and ICT service providers.
+- E&M sector:** Located on the right, it includes TVs, TV peripherals, TV networks, Other consumer electronics, Paper media and printing, and ICT services and E&M content production.
+
+Below the central internet globe, there are also icons for **Enterprise networks and data centres** and **User equipment Business PCs and office equipment**.
+
+Figure III.1 – ICT sector overview. A diagram showing the ICT sector divided into four main sub-sectors: User equipment, Access networks, Operator activities, and E&M sector, all connected to a central Global Internet.
+
+L.1470(20)\_FIII.1
+
+Figure III.1 – ICT sector overview
+
+Electricity consumption in the use stage per respective area has been converted to CO2 e using emission factors. GHG emissions from the other life cycle stages are treated separately and reflect geographical locations.
+
+For user devices, a combination of LCA data and production data from the leading ICT companies and equipment manufacturers has been used, which leads to a more accurate estimate of the embodied emissions than just using old LCA data. Data for different products have been compiled, together with sales statistics for these devices.
+
+As stated in section 6 of [b-Malmodin 2018a], the study strived for alignment with [ITU-T L.1450]:
+
+This study has used the joint LCA standard by ITU/ETSI for ICT networks [ITU-T L.1450] and the principles of relevance, completeness, consistency, accuracy, and transparency to guide the work. In addition, the study has strived to be well aligned with the ITU standard for the carbon footprint of the ICT sector [ITU-T L.1450]. Overall, the choice of functional units and boundary setting is in line with the standard and the study also takes a life cycle approach and considers both hardware and software. At a product level, a major data collection effort was undertaken to find data in line with the standards' requirements. From a data quality point of view, the principles of completeness, uncertainty, data representativeness, data age, geographical and technological correlation have been considered in this process. Cut offs have been avoided as far as possible and the use of proxy data and extrapolations have been preferred, and energy emission factors are inclusive by considering the supply chain and distribution losses. Also, from an allocation perspective, the rules of the standard have been considered. No sensitivity analysis was performed but results for different parts are transparently presented to enable postprocessing. The reporting is not performed in accordance with the standards but adopts to the format of the journal [*Sustainability*]. Finally, no third party critical review of standard compliance has been performed, but the authors preferred to send the study for review.
+
+For the input studies performed by the authors themselves, the input data have high degree of compliance with the standard according to previous evaluations. For user devices, a detailed standardization review was performed during this study and it was noted that existing studies, in most cases, have a low degree of transparency, which makes it hard to judge their quality. Furthermore, none of the reviewed sources referred to any LCA standard. For this reason, the used complementary top-down data sources were considered important to validate the LCA data collected. For data centers, no compliance review was performed but the quality of the input data should be secured through the scientific peer review of the academic papers and the broad consultation performed for the IEA deliverable.
+
+See Table III.1.
+
+**Table III.1 – Baseline overview for the entire ICT sector 2015**
+
+| | Electricity consumption | CO 2 emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|-------------------------------------------------------------------|-------------------------|-----------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | (Perspective A) | (Perspective B) |
+| Mobile networks | | | |
+| Mobile network manufacturers (s1-s2) | 5 | 3 | 3 |
+| Mobile network manufacturers, T&D (s3) | | 0.3 | – |
+| Mobile network manufacturers, electricity supply (s3) | | 0.45 | – |
+| Mobile network operator overheads – electricity (s2) | 13 | 6.4 | 6,4 |
+| Mobile network operator overheads – excluding electricity (s1-s2) | | 4 | 4 |
+| Mobile network own electricity generation (s1-s2) | 27 | 25 | 25 |
+| Mobile network electricity consumption (s2) | 90 | 48 | 48 |
+| Mobile network electricity consumption, T&D (s3) | | 5.4 | – |
+| Mobile network electricity consumption, electricity supply (s3) | | 8.2 | – |
+| Mobile network supply chain s3 | | 12 | 12 |
+| Mobile network supply chain, T&D (s3) | | 0.75 | – |
+| Mobile network supply chain, electricity supply (s3) | | 1.5 | – |
+| Fixed networks | | | |
+
+**Table III.1 – Baseline overview for the entire ICT sector 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|--------------------------------------------------------------------|-------------------------|-------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | (Perspective A) | (Perspective B) |
+| Fixed network manufacturers (s1-s2) | 1.7 | 1 | 1 |
+| Fixed network manufacturers, T&D (s3) | | 0.1 | – |
+| Fixed network manufacturers, electricity supply (s3) | | 0.15 | – |
+| Fixed network operator overheads – electricity (s2) | 7 | 3.2 | 3,2 |
+| Fixed network operator overheads – excluding electricity (s1-s2) | | 2 | 2 |
+| Fixed network electricity consumption (s2) | 85 | 43.2 | 43 |
+| Fixed network electricity consumption, T&D (s3) | | 4.6 | – |
+| Fixed network electricity consumption, supply (s3) | | 6.9 | – |
+| Fixed network supply chain s3 | | 4.5 | 6 |
+| Fixed network supply chain, T&D (s3) | | 0.5 | – |
+| Fixed network supply chain, electricity supply (s3) | | 0.75 | – |
+| Data centres | | | |
+| Data centre manufacturers s1-s2 | 5 | 3 | 3 |
+| Data centre manufacturers, T&D (s3) | | 0.3 | – |
+| Data centre manufacturers, electricity supply (s3) | | 0.45 | – |
+| Data centre operator overheads (electricity) s2 | 15 | 6.4 | 6,4 |
+| Data centre operator overheads (excluding electricity) s1-s2 | | 3 | 3 |
+| Data centre electricity consumption (s2) | 205 | 91.2 | 91,2 |
+| Data centre electricity consumption, T&D (s3) | | 9.1 | – |
+| Data centre electricity consumption, supply (s3) | | 13.7 | – |
+| Data centre supply chain s3 | | 12 | 12 |
+| Data centre supply chain, T&D (s3) | | 0.75 | – |
+| Data centre supply chain, electricity supply (s3) | | 1.5 | – |
+| User devices | | | |
+| User device manufacturers (non-electricity) | | 35 | 35 |
+| User device manufacturers electricity (s2/s3) | 149 | 70 | 70 |
+| User device manufacturers, T&D (s3) | | 7 | – |
+| User device manufacturers, electricity supply (s3) | | 10.5 | – |
+| User device operation (s3) | 345 | 169 | 169 |
+| User device operation (T&D, s3) | | 17 | – |
+| User device operation, electricity supply (s3) | | 25 | – |
+| User device supply chain non-electricity s3 | | 35 | 35 |
+| User device supply chain, electricity (s3) | 56 | 26 | 26 |
+| User device supply chain, T&D (s3) | | 2.6 | – |
+| User device supply chain, electricity Supply (s3) | | 3.9 | – |
+| Enterprise networks: | | | |
+| Enterprise networks manufacturers electricity (s2/s3) | | 0.5 | 0,5 |
+| Enterprise networks manufacturers, T&D (s3) | | 0.05 | – |
+| Enterprise networks devices manufacturers, electricity supply (s3) | | 0.08 | – |
+| Enterprise networks operation (s2/s3) | 25 | 12 | 12 |
+| Enterprise networks operation (T&D, s3) | | 1.2 | – |
+| Enterprise networks operation (supply, s3) | | 1.8 | – |
+| Total | | | |
+| Total including grid electricity supply and losses | | 740 | – |
+| Total excluding grid electricity supply and losses | | – | 617 |
+
+**Table III.1 – Baseline overview for the entire ICT sector 2015**
+
+| | Electricity consumption | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) |
+|----------------------------------------------------------------------|-------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|
+| | 2015 (TWh) | (Perspective A) | (Perspective B) |
+| Number of mobile subscriptions (SIM-cards excluding M2M) | 7.2 billion | [b-Ericsson 1994-2020] [b-GSMA] | |
+| Number of fixed subscriptions (lines) | 1.85 billion | [b-ITU 2005–2019] | |
+| Number of servers (datacentres) | 43 million | Calculated from sales and lifetime | |
+| Number of active PC or employee "users" (enterprises) | 800 million | Calculated from sales and lifetime | |
+| Number of end-user goods | 13 billion | [b-Malmodin 2018a] | |
+| Number of additional IoT/M2M (possible, included in forecast) | 2 billions | Calculated | |
+| Fixed data traffic (ZB) | 1 | [b-Cisco]https://www.cisco.com/c/en/us/solutions/service-provider/visual-networking-index-vni/index.html | |
+| Mobile data-traffic (ZB) | 0.06 | [b-Ericsson 1994-2020] | |
+
+This table is colour-coded according to clause 5.
+
+### III.2 Description
+
+This clause provides background information for the baseline.
+
+#### III.2.1 Emission factors
+
+For embodied emissions, emission factors are embodied in the background studies and based on actual conditions.
+
+For operation, the following data have been combined with world average emission factors based on IEA reporting of actual conditions:
+
+- with ES chain and loss, the factor is estimated to be 0.63 kg CO2 e/kWh (2015);
+- without ES chain and loss, the factor is estimated to be 0.506 kg CO2 e/kWh (2015).
+
+#### III.2.2 Mobile networks
+
+##### III.2.2.1 Operation
+
+###### Data sources
+
+Published data collected from operators listed in clause III.3 (with further details in section II of [b-Malmodin 2018a]).
+
+More detailed data collected from nine anonymous European Telecommunications Network Operators (ETNO) or GESI members as described in clause III.3 (with further details in [b-Malmodin 2018c]). This data set was used to allocate between mobile, fixed, overheads etc.
+
+###### Calculation
+
+- The electricity usage and CO2 e data from individual operators (section II of [b-Malmodin 2018b]) were added and the result was extrapolated based on subscriptions to arrive at an overall electricity usage per network type
+
+- CO2 e figures include overheads, scope 1-2, and scope 3 for travels – usage of mobile phones excluded to avoid double counting.
+- The allocation between mobile and fixed networks was based on subscriptions as derived in [b-Malmodin 2018c] from more than 10 operators with detailed reporting
+- The allocation to overheads activities was based on Figures 6 and 8 of [b-Malmodin 2018c]
+- Operator data centres (20 TWh, p. 13 of [b-Malmodin 2018c]) were excluded and allocated to the data centre category based on Figure 6 of [b-Malmodin 2018c].
+
+##### III.2.2.2 Embodied
+
+Embodied emissions are based on Table 4 of [b-Malmodin 2014a]. The main part of this is due to network deployment and construction but the factors include also the embodied emissions of the ICT equipment.
+
+**Table III.2 – Embodied carbon footprint for network deployment and construction in Sweden and globally (estimated from Swedish data)**
+
+| Embodied emissions | Sweden | Global estimate |
+|--------------------|---------------------------------------|-------------------------------------|
+| Fixed telephony | 7,3 kg CO 2 e/line | 5 kg CO 2 e/line |
+| Fixed broadband | +1,1 kg CO 2 e/line | +1 kg CO 2 e/line |
+| Mobile | 3,5 kg CO 2 e/subscription | 2 kg CO 2 e/subscription |
+
+For network construction and deployment, values from [b-Malmodin 2014a] were adjusted for the difference between Swedish and global conditions.
+
+"The embodied carbon footprint for ICT network operators is mainly related to the construction and deployment of the network infrastructure like digging down cable ducts and raising antenna towers. The footprint of these activities has been estimated based on extensive studies of construction and deployments of telecom networks in Sweden, see Table 4. Lower averages have been estimated globally as Sweden has both a low population density and high requirements on connectivity which increases the network infrastructure impact as well as costs. Note that the deployment or embodied carbon footprint has been spread out over the whole lifetime and the values in Table 4 represent the annual carbon footprint for the network infrastructure deployment and construction which can vary substantially over time.
+
+
+
+| Sector | Sub-sector | Manufacturing (Mton CO 2 e) | Operation (Mton CO 2 e) | Total (Mton CO 2 e) |
+|-------------------|---------------------------------------|----------------------------------------|------------------------------------|--------------------------------|
+| A) The ICT sector | User devices | ~170 | ~280 | ~450 |
+| | Networks | ~20 | ~150 | ~170 |
+| | Data centers | ~15 | ~130 | ~145 |
+| | Paper media | 0 | 0 | 0 |
+| | ICT/E&M services (New total estimate) | ~30 | ~10 | ~40 |
+| B) The E&M sector | User devices | ~140 | ~310 | ~450 |
+| | Networks | ~10 | ~10 | ~20 |
+| | Data centers | ~5 | ~5 | ~10 |
+| | Paper media | ~180 | ~270 | ~450 |
+| | E&M content incl. in ICT/E&M services | ~10 | ~10 | ~20 |
+
+Figure comparing CO2e emissions for the ICT and E&M sectors across various sub-sectors, divided into manufacturing and operation components.
+
+The overall embodied emissions for all sub-sectors were validated based on
+
+- The energy and carbon footprints of the major ICT and E&M manufacturing companies were collected and scaled to a global level based on revenue. See [b-Malmodin 2018a] section 4.10 [b-Malmodin 2018b] III.
+- The contribution from materials extraction was also derived top-down in accordance with [b-Malmodin 2018d], which estimates the material carbon footprint of the ICT and E&M sector to be about 45 Mt CO2 e."
+
+#### III.2.3 Fixed networks
+
+##### III.2.3.1 Operation
+
+- The electricity usage and CO2 e data from individual operators (section II of [b-Malmodin 2018b]) were added and the result was extrapolated based on subscriptions to arrive at an overall electricity usage per network type
+ - CO2 e figures include overheads, scope 1-2, and scope 3 for travels – usage of mobile phones excluded to avoid double counting.
+- Allocated to mobile and fixed networks, respectively, based on impact per subscriber as derived in [b-Malmodin 2018c] from the 10 or more operators with detailed reporting
+- Allocated to overheads based on Figures 6 and 8 of [b-Malmodin 2018c]
+- Operator data centres (20 TWh, p. 13 of [b-MalmodinLundén 2018a]) were excluded and allocated to category data centre based on Figure 6 of [b-Malmodin 2018c]
+
+##### III.2.3.2 Embodied
+
+See clause III.2.2.2.
+
+#### III.2.4 Data centres
+
+##### III.2.4.1 Operation
+
+2014–2020 based on [b-IEA Digitalization] in accordance with [b-Malmodin 2018a].
+
+However, the electricity consumption of data centres is estimated to be slightly higher than the IEA estimate of 194 TWh for 2014, about 205 TWh for 2015 (220 TWh including overheads). The difference compared to IEA is that slightly more servers are estimated to be in operation due to estimated longer lifetime (4.5 years per server).
+
+Renewables separated before applying emission factor
+
+The model applied is based on energy usage per server based on [b-Shehabi], [b-Fuchs] and personal communication with IEA author.
+
+##### III.2.4.2 Embodied
+
+Based on detailed reporting by [b-Google 2016a], [b-Google 2016b] and [b-Facebook], scaled to all data centres based on their share of terawatt hours.
+
+##### III.2.4.3 Overhead
+
+Based on detailed reporting by [b-Google 2016a] , [b-Google 2016b] and [b-Facebook], scaled to all data centres based on their share of terawatt hours.
+
+The energy consumption related to offices and travel for data centre operators has been included in the footprints, together with the embodied footprint of equipment and infrastructure. These data are based on reports by [b-Google 2016a], [b-Google 2016b] and [b-Facebook], and the estimated total carbon footprint for data centres and enterprise networks is about 160 Mt CO2 e. About 135 Mt of the carbon footprint is related to the electricity consumption (240 TWh) taking reported green electricity into account, and about 25 Mt comes from construction and manufacturing and a smaller share from non-electric energy used at sites, transports and travel.
+
+#### III.2.5 User devices
+
+##### III.2.5.1 Categories
+
+Fixed phones (PSTN and voice over Internet protocol (VoIP)), smartphones, other mobile phones, CPE (modems, gateways), tablets, laptop PCs, desktop PCs, computer displays, computer peripherals, projectors, public displays, surveillance cameras, payment terminals, wearables, smart meter connectivity.
+
+##### III.2.5.2 Calculation
+
+Each category has been calculated as:
+
+Total footprint per category calculated as
+
+$$\text{Embodied} + \text{Operational} = A * C + D * E * F$$
+
+where $A$ , $C$ , $D$ and $E$ are given in the column headings to Table III.3; $F$ depends on scenario, see clause IV.2.1.
+
+Note that embodied emissions include the year of shipment.
+
+##### III.2.5.3 Data sources
+
+**Table III.3 – Summary of data sources. For details refer to the source documents**
+
+| ICT sector | Total shipments a | Embodied CF per device | Devices in operation a | Lifetime assumptions | Annual average OEC |
+|----------------------------|--------------------------------|---------------------------------------------------------------|-------------------------------------------------------|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | millions | kg CO 2 e (est.) | millions | years | kWh |
+| | A | C | D | | Eb |
+| Fixed phones (PSTN + VoIP) | ITU | S6.1.2 of [b-Malmodin 2014b] Table 2 of [b-Malmodin 2018a] | ITU | 8.3 | Based on input data from Table 1 of [b-Malmodin 2014a] + S6.1.2 of [b-Malmodin 2014b], adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Smartphones | Gartner, IDC | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Gartner, IDC | 3.0 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b], adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Other mobile phones | Gartner | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Gartner | 5.0 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b], adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| CPE (modems, gateways) | Future Source/IHS c | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Future Source/IHS c | 5.0 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b], adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Tablets | IDC | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 3.4 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b], adjusted for development in [b- |
+
+**Table III.3 – Summary of data sources. For details refer to the source documents**
+
+| ICT sector | Total shipments a | Embodied CF per device | Devices in operation a | Lifetime assumptions | Annual average OEC |
+|----------------------|------------------------------|-----------------------------------------------------------------------------------|-------------------------------------------------------|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | millions | kg CO 2 e (est.) | millions | years | kWh |
+| | A | C | D | | Eb |
+| | | | | | Malmodin 2018a], [b-Malmodin 2018c] |
+| Laptop PCs | IDC | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 5.0 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b] (S2), adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Desktop PCs | IDC | S2 of [b-Malmodin 2014b] (S2), Table 2 of [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 5.0 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b] (S2), adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Computer displays | IHS c | S2 of [b-Malmodin 2014b], Table 2 of [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 7.7 | Based on input data from Table 1 of [b-Malmodin 2014a] + S2 of [b-Malmodin 2014b], adjusted for development in [b-Malmodin 2018a], [b-Malmodin 2018c] |
+| Computer peripherals | Future Source | Table 2 of [b-Malmodin 2018b] | Estimated from yearly shipment + operational lifetime | na | na |
+| Projectors | IHS c | Estimated based on device weight [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 6.3 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+| Public displays | IHS c | Estimated based on screen sized from other display LCA figures [b-Malmodin 2018a] | Estimated from yearly shipment + operational lifetime | 7.1 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+
+**Table III.3 – Summary of data sources. For details refer to the source documents**
+
+| ICT sector | Total shipments a | Embodied CF per device | Devices in operation a | Lifetime assumptions | Annual average OEC |
+|--------------------------|------------------------------|-----------------------------------------------------------------------------------|-----------------------------------|----------------------|------------------------------------------------|
+| | millions | kg CO 2 e (est.) | millions | years | kWh |
+| | A | C | D | | E b |
+| Surveillance cameras | IHS c | Estimated based on device weight [b-Malmodin 2018a] | IHS c | 5.0 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+| Payment terminals | BI Intelligence d | Estimated based on device weight [b-Malmodin 2018a] | BI Intelligence d | 4.3 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+| Wearables | IDC | Estimated based on device weight [b-Malmodin 2018a] | IDC | 3.5 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+| Smart meter connectivity | Pike Research e | Estimated based on device weight ([b-Malmodin 2018a], [b-Malmodin, Coroama 2016]) | Pike Research e | 10.0 | Estimate used in Table 2 of [b-Malmodin 2018b] |
+
+a Table III.5 gives an overview of data sources that are further detailed in [b-Malmodin 2019b].
+
+b Usage scenarios behind the data used for *E* for all categories above Projectors are mainly based on: [b-Stobbe], [b-Urban].
+
+c The successor company is OMDIA.
+
+d Company now known as Business Insider.
+
+e The successor company is Guidehouse Insights.
+
+##### References
+
+[b-Malmodin 2014a]; [b-Malmodin 2018a]; [b-Malmodin 2018b];
+
+[b-Malmodin 2018c]; [b-MalmodinCoroama 2016]; [b-Malmodin 2018a];
+
+[b-Malmodin 2018c].
+
+References for those studies include 10 LCAs of feature phones, 7 LCAs of smartphones, 12 LCAs for laptop PCs and 12 LCAs for desktop PCs.
+
+#### **III.2.6 Enterprise networks**
+
+Enterprise networks have been estimated based on estimates of number of network ports, number of work or office PCs, additional so called small cells or WLAN network equipment.
+
+As with most other equipment and devices, global annual sale figures from recent years have been used together with measured data from large samples. The sample size is in this case limited to in-house operations, but large global information technology (IT) service providers have also contributed with knowledge and data. Enterprise network overheads can be estimated at 27 kWh/year on average per active employee with a PC.
+
+Sources: [b-Shehabi], [b-Stobbe].
+
+### **III.3 Main data sources (in addition to academic papers)**
+
+#### **III.3.1 Summary**
+
+The following data sets have been collected:
+
+- published data for 36 network operators (listed in Table III.4);
+- directly collected data for 10 network operators (under non-disclosure agreement (NDA));
+- published data for 31 manufacturers (listed in Table III.4);
+- published data for 10 data centre operators (specified below).
+
+In addition, embodied LCAs from about 30 studies (as defined by all Malmodin papers listed in the bibliography).
+
+Academic references cited in all Malmodin papers listed in the bibliography.
+
+The same company may occur in more than one category.
+
+#### **III.3.2 Directly reported data used for detailed allocation between different network parts:**
+
+Data for about 10% of the global fixed and mobile subscriptions have been collected under NDA directly from nine operators that are ETNO or GESI members. This granular data set makes it possible to see details for fixed and mobile networks, as well as the distribution of electricity consumption and operational carbon emissions between the network itself and an operator's own data centre, offices and stores.
+
+Included:
+
+- network electricity (and diesel for mobile networks);
+- fixed telephony access networks (also known as PSTN or plain old telephone service (POTS));
+- mobile access networks of all generations, including all diesel consumption;
+- fixed broadband access networks;
+- data transmission and Internet protocol (IP) core network.
+
+Operator activities or overheads:
+
+- electricity and other energy in data centres, offices and stores;
+- business travel and fleet vehicles used for field service operations.
+
+To verify that confidential data from operators are reliable and accurate is a challenge. However, since many operators also publish annual reports with the same data, but presented with lower granularity, the data has to a large extent been compared to those sources, which are verified through corporate audit review. Operators that reported their detailed data were promised anonymity. Through
+
+this, data gaps were avoided, and access was given to data sets that would otherwise have remained internal.
+
+See Figure III.3.
+
+
+
+Estimated share (Total is primary measured data)
+
+Average
+80% network
+9% data centres
+11% offices etc.
+
+Operator 1
+
+Operator 2
+
+Operator 3
+
+Operator 4
+
+Operator 5
+
+Operator 6
+
+Operator 7
+
+Operator 8
+
+Operator 9
+
+0 20 40 60 80 100 %
+
+■ Data centres ■ Offices, stores etc. ■ Network
+
+L.1470(20)\_FIII.3
+
+| Operator | Data centres (%) | Offices, stores etc. (%) | Network (%) |
+|------------|------------------|--------------------------|-------------|
+| Operator 1 | ~10 | ~10 | ~80 |
+| Operator 2 | ~10 | ~10 | ~80 |
+| Operator 3 | ~10 | ~10 | ~80 |
+| Operator 4 | ~10 | ~10 | ~80 |
+| Operator 5 | ~10 | ~10 | ~80 |
+| Operator 6 | ~10 | ~10 | ~80 |
+| Operator 7 | ~10 | ~10 | ~80 |
+| Operator 8 | ~10 | ~10 | ~80 |
+| Operator 9 | ~10 | ~10 | ~80 |
+
+Horizontal stacked bar chart showing the estimated share of total electricity consumption for nine operators. The chart is divided into three categories: Data centres (yellow), Offices, stores etc. (orange), and Network (dark orange). A callout box indicates the average distribution: 80% network, 9% data centres, and 11% offices etc. The x-axis represents the percentage from 0 to 100%.
+
+Reference: [b-Malmodin 2018c]
+
+**Figure III.3 – Distribution of total electricity consumption for consolidated directly reported data**
+
+#### **III.3.3 Complementary data sources [b-Malmodin 2018b]**
+
+See Tables III.4, III.5 and III.6.
+
+**Table III.4 – Listing of telecommunication operators, data centre operators and manufacturers**
+
+| Telecommunication operator | Data centre operator | Manufacturer |
+|---------------------------------------|-----------------------------|---------------------|
+| AT&T | Facebook | Apple |
+| Verizon | Google | Samsung |
+| China Mobile | Apple | Foxconn |
+| NTT | Microsoft | HP |
+| DT | SAP | IBM |
+| Softbank | Accenture | Dell |
+| Vodafone | Oracle | Sony |
+| América Móvil | Amazon | Panasonic |
+| China Telecom | Tencent | Huawei |
+| Telefonica | Equinix | Intel |
+| Orange | | LG Electronics |
+| China Unicom | | Lenovo |
+| KDDI | | Cisco |
+| British Telecom | | Fujitsu |
+| Telecom Italia | | Pegatron |
+| Telstra | | Quanta Computer |
+| BCE | | China Electronics |
+| Telenor | | Canon |
+| Vimpel com | | Ericsson |
+| Axiata | | TSMC |
+| Singtel | | NEC |
+| SK Telecom | | LG Display |
+| Bharti Airtel | | Compal |
+| Bharti Airtel | | Flextronics |
+| MTN | | Micron |
+| TRAI (10 operators, excluding Airtel) | | SK Hynix |
+| | | TI |
+| | | Innolux |
+| | | AUO |
+| | | BEO |
+| | | JDI |
+| Totals | | |
+| 36 | 10 | 31 |
+
+**Table III.5 – Key data sources in summary**
+
+| | |
+|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Data centres (DCs) All use of servers from "in closets" to "hyper scale" DCs | This study relies on [b-Koomey] and other studies in the US [b-Shehabi] plus [b-IEA Digitalization]. Reported data from ICT companies cover about 15% of final estimated electricity consumption. |
+| ICT networks PSTN (telephony), mobile networks, fixed networks | Detailed data from a new report [b-Malmodin 2018c] that covers about 40% of mobile and about 15% of fixed subscriptions globally. High-level data for about 70% of all subscriptions have also been collected in this study. |
+| Enterprise networks (reported with data centres) | Enterprise networks estimated based on average network ports [b-Shehabi] and experience of operating large "Intranets". |
+| Data centres | To avoid double accounting, ICT network operator and ICT and E&M manufacturer data centres have been fully allocated to "Data centres". |
+| Enterprise networks and office devices | Network operator and equipment manufacturer own networks and devices included in their reported totals, except for personal user devices. |
+| Cable TV networks | A share for fixed broadband over cable TV have been allocated to ICT network operations. |
+| User devices | |
+| Gartner Smartphones, other mobile phones, tablets, laptop PCs, desktop PCs | [b-Gartner] |
+| IDC Smartphones, other mobile phones, tablets, laptop PCs, desktop PCs, wearables, servers, hardcopy devices | Worldwide quarterly mobile phone tracker [b-IDC 37]Worldwide quarterly personal computing device tracker [b-IDC 1541]Worldwide quarterly wearable device tracker [b-IDC 962]Worldwide quarterly server tracker [b-IDC 7]Worldwide quarterly hardcopy peripherals tracker [b-IDC 3] |
+| OMDIAa Computer displays, public displays, surveillance cameras, automotive (all display products) | Desktop monitor market tracker [b-OMDIA 2020c] Public display market tracker [b-OMDIA 2020d] Security technology [b-OMDIA 2020e] Small and Medium Display Market Tracker [b-OMDIA 2020f] |
+| Future source CPE (modems, gateways), computer peripherals, set-top boxes (STBs), digital versatile disc/Blu-ray disc (DVD/BD) players, media players, home audio systems, portable media players, headphones, cameras | [b-Future Source] is one of the leading analysts for not only audio and camera products, but also CPEs (gateways, modems, etc.), STBs and projectors, as well as optical and electronic media (discs, memory sticks or cards, printer consumables), See also: [b-Koenig] |
+| Jon Peddie Research (JPR) Camcorders, game consoles, portable game consoles, arcade game machines | [b-JPR2014] |
+| a Successor company to HIS. | |
+
+**Table III.6 – ICT subscriptions globally and other key data**
+
+| ICT subscriptions (millions) | 2015a | Data sources |
+|----------------------------------------------------------------|-------------------------|---------------------|
+| Fixed telephony (voice) | 1 070 | [b-ITU 2005–2019] |
+| Additional VoIP subscriptions | ~250 | [b-ITU 2005–2019] |
+| Mobile subscriptions | 7 110 | [b-ITU 2005–2019] |
+| of which is mobile broadband | 2 950 | [b-ITU 2005–2019] |
+| Additional M2M (IoT) subscriptions | 350 | [b-GSMA] |
+| Fixed broadband (lines) | 775 | [b-ITU 2005–2019] |
+| Of which is FTTH/FTTB | 160 | [b-ITU 2005–2019] |
+| Of which is cable-TV | 150 | [b-DTVR] |
+| | | |
+| ICT total subscriptions (not including M2M subs) | 8 955 | |
+| Other global key data | 2 015 | |
+| Data traffic (EB) | 910 | [b-Cisco] |
+| Smartphone share of data traffic (%) | ~10 | [b-Cisco] |
+| Electricity consumption (TWh) | 21 000 | [b-Enerdata] |
+| Energy-related CO 2 emissions (Mt CO 2 ) | 32 300 | [b-IEA Fuel] |
+| Carbon footprint (Mt CO 2 e) | 53 400 | [b-Olivier] |
+
+a Subscription numbers are counted at mid-year, not end-of-year.
+
+## Appendix IV
+
+### ICT sector trajectories for 1.5°C
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix explores opportunities for the ICT sector to develop in line with a 1.5°C scenario, taking into account the historical development and footprint of the sector based on reported data from around 100 ICT companies and knowledge about the parameters that drive electricity consumption. The purpose of the trajectory is to explore the ability of ICTs to reduce their emissions in line with an average P2 decline or faster.
+
+This trajectory thus starts from the different parameters that impact energy consumption and hence GHG emissions and tries to anticipate their overall effect on the future development of the overall sector footprint and energy usage. With all the complexities of the sector, such an approach could capture effects that elude a single intensity metric.
+
+To illustrate the complexity of the ICT sector footprint in the case of wireless networks, a wireless network consists of radio base station sites of various ages, access standards support and configurations. At a site level, energy consumption is decided not only by Moore's law and processor capacity, but also attenuation by analogue filters and losses in power or antenna cables, signal treatment algorithms like schedulers, the efficiency of radio amplifier circuitry, overall site configuration including efficiency of alternating current (AC) to DC and DC to DC transformers, cooling equipment and its adaptation. Historically, radio base station products have been optimized more on low latency, capacity and speed than on energy consumption, but software layer features are nowadays available to put the equipment in sleep mode during shorter or longer pauses in operation to save energy. However, different operators use such features to a varying extent. At a network level, the number of base stations and the output power needed for coverage and capacity depends on cell planning, which in turn depends on factors such as topologies, frequency and compromises between energy consumption and other performance indicators. At top level, operators may combine various systems in different ways, e.g., by phasing out an older system when a new one is launched.
+
+Thus, to consider only one of these aspects is not sufficient to understand how network energy consumption might evolve – and to model all of them would create a very complex model. This is the reason why focusing on macro trends related to network development and energy consumption gives a more comprehensive assessment.
+
+The importance of energy cost should also be mentioned. In an industry where end-consumers are accustomed to getting more and more capabilities for the same amount of money, together with competition and expected increase in energy prices in the long run, there are economic restrictions that determine how energy consumption might evolve in the future. The cost aspect with regards to investment also restricts how fast a global trajectory might change.
+
+The trajectory is described in a step-wise procedure as follows.
+
+- **ICT's own development (step 1):** The development of the ICT sector footprint is estimated with the grid emission factor and renewables held fixed at 2015 levels (as described in Appendix III). The intention of this step is to show the changes related to the ICT sector itself (see clause IV.1).
+- **ICT and grid development (step 2):** The development of the ICT sector is estimated with renewables held at 2015 levels, but with the grid developing in accordance with the chosen 1.5°C scenario (see clause IV.2).
+- **ICT and grid development plus additional purchase of renewables (step 3):** The development of the ICT sector and its additional capacity are estimated to purchase or invest
+
+in renewables and with the grid developing in accordance with the chosen 1.5°C scenario (see clause IV.3).
+
+For each step, two sets of values are derived. The first includes scope 1-2 emissions of electricity in line with company accounting principles (perspective A), and the second also includes the value chain emissions of the electricity and distribution losses of the grid to reflect the full footprint of the sector (perspective B).
+
+#### IV.1 Step 1: ICT's own development
+
+The starting point for this scenario is current and historical trends for operation and other life cycle stages for the different parts of the ICT sector based on data for 2007, 2010 and 2015 as described in [b-Malmodin 2010], [b-Malmodin 2013], [b-Malmodin 2018a] and [b-Malmodin 2018c].
+
+This clause describes the approach undertaken when exploring the 1.5°C scenario for the ICT sector. The overall assessment approach used for the sector is the same as for the baseline described in Appendix III. Thus, this clause only describes specific assumptions or deviations.
+
+NOTE – This first step does not include any improvements in the power sector or the possibility to reduce emissions by additional purchases or investments in renewables. This means that the emission factors for grid electricity are in line with those used for the baseline. See Appendix III.
+
+Figure IV.1 summarizes the sub-sector trajectories described in clauses IV.1.1 to IV.1.5.
+
+
+
+| Perspective / Year | 2015 | 2020 | 2025 | 2030 |
+|------------------------------|------|------|------|------|
+| Perspective A (Total) | ~750 | ~770 | ~800 | ~820 |
+| Perspective B (Total) | ~620 | ~630 | ~650 | ~680 |
+
+The figure consists of two side-by-side stacked area charts, labeled (a) and (b). Both charts have a y-axis labeled 'Mt CO2 e' ranging from 0 to 1000 and an x-axis showing years from 2015 to 2030. The legend at the bottom identifies five categories: Enterprises networks (red), User devices (yellow), Data centres (green), Fixed networks (light blue), and Mobile networks (dark blue).
+
+Chart (a), titled 'Including T&D losses and fuel supply', shows a total emission increase from approximately 750 Mt CO2 e in 2015 to about 820 Mt CO2 e in 2030. Chart (b), titled 'Excluding T&D losses and fuel supply', shows a lower total emission increase, reaching approximately 680 Mt CO2 e by 2030. In both charts, the 'User devices' category (yellow) is the most significant contributor, followed by 'Mobile networks' (dark blue), 'Data centres' (green), 'Fixed networks' (light blue), and 'Enterprises networks' (red).
+
+L.1470(20)\_FIV.1
+
+Figure IV.1: Two stacked area charts showing ICT sector carbon footprint development from 2015 to 2030. Chart (a) includes T&D losses and fuel supply (perspective A), while chart (b) excludes them (perspective B). Both charts show a general increase in emissions over time, with 'User devices' being the largest contributor in both scenarios.
+
+**Figure IV.1 – ICT sector carbon footprint development 2015–2030 with constant grid emission factor: a) includes grid supply chain and distribution losses (perspective A); b) excludes grid supply chain and distribution losses (perspective B).**
+
+#### IV.1.1 Mobile networks
+
+##### IV.1.1.1 Boundaries
+
+The boundaries are defined in accordance with Annex A of [ITU-T L.1450]:
+
+- this subcategory includes wireless access network goods and mobile core goods. (item 2) of the first list in clause A.3 of [ITU-T L.1450]);
+- it further includes support goods;
+- operator support activities are included and shown separately;
+- operator data centres are excluded as they have been allocated to the sub-sector data centres;
+
+- the boundary towards wireline networks is drawn after mobile core, all common network functions are allocated to fixed networks;
+- end-user goods owned by operators are not included in this sub-sector, as they have been allocated to end-user goods.
+
+##### IV.1.1.2 Activity level
+
+The future development of the sector starts from the forecasts of [b-Ericsson MR 2019], an annual report first published 2016, which provides projections and analyses of the latest trends in the mobile industry, including subscription, mobile data traffic and population coverage. The forecasts are based on past and current data and validated with extensive network measurements.
+
+Figure IV.2 shows how different mobile networks are expected to develop until 2024 with regards to population coverage and number of subscriptions per access standard (2G to 5G).
+
+
+
+**a) Population coverage**
+
+| Year | 5G (%) | LTE (%) | All 3GPP cellular technologies (%) |
+|------|--------|---------|------------------------------------|
+| 2018 | 0 | ~75 | ~95 |
+| 2019 | 0 | ~80 | ~95 |
+| 2020 | ~5 | ~85 | ~95 |
+| 2021 | ~15 | ~90 | ~95 |
+| 2022 | ~25 | ~90 | ~95 |
+| 2023 | ~35 | ~90 | ~95 |
+| 2024 | ~45 | ~90 | ~95 |
+
+**b) Mobile subscriptions**
+
+| Year | 5G (M) | LTE (M) | WCDMA/HSPA (M) | GSM/EDGE (M) | TD-SCDMA (M) | CDMA (M) | Other technologies (M) |
+|------|--------|---------|----------------|--------------|--------------|----------|------------------------|
+| 2015 | 0 | ~1000 | ~2000 | ~3000 | ~1000 | ~1000 | ~1000 |
+| 2016 | 0 | ~1200 | ~2200 | ~3200 | ~1000 | ~1000 | ~1000 |
+| 2017 | 0 | ~1500 | ~2500 | ~3500 | ~1000 | ~1000 | ~1000 |
+| 2018 | 0 | ~1800 | ~2800 | ~3800 | ~1000 | ~1000 | ~1000 |
+| 2019 | ~200 | ~2200 | ~3000 | ~4000 | ~1000 | ~1000 | ~1000 |
+| 2020 | ~500 | ~2500 | ~3200 | ~4200 | ~1000 | ~1000 | ~1000 |
+| 2021 | ~1000 | ~2800 | ~3000 | ~4000 | ~1000 | ~1000 | ~1000 |
+| 2022 | ~1500 | ~3000 | ~2800 | ~3800 | ~1000 | ~1000 | ~1000 |
+| 2023 | ~2000 | ~3200 | ~2500 | ~3500 | ~1000 | ~1000 | ~1000 |
+| 2024 | ~2500 | ~3500 | ~2200 | ~3200 | ~1000 | ~1000 | ~1000 |
+
+Figure IV.2: a) Population coverage 2018–2024 and b) subscription forecasts and trends 2015–2024. Chart (a) shows population coverage in percent from 2018 to 2024 for 5G, LTE, and All 3GPP cellular technologies. Chart (b) shows mobile subscriptions in millions from 2015 to 2024 for 5G, LTE, WCDMA/HSPA, GSM/EDGE, TD-SCDMA, CDMA, and Other technologies.
+
+Source: visualization of [b-Ericsson MR 2019].
+
+**Figure IV.2 – a) Population coverage 2018–2024 and b) subscription forecasts and trends 2015–2024**
+
+- Development in number of subscriptions is based on [b-Ericsson MR 2019] according to Figure IV.1 until 2024, and extrapolated thereafter.
+- Number of subscriptions refers to the number of current subscriber identity module (SIM) cards, excluding M2M.
+- However, M2M electricity consumption is considered in the footprint energy values.
+- Number of subscribers is related to billing and is less relevant as a metric because the relationship to usage is less straight forward.
+- Historic geographical distribution is considered in accordance with development seen from 1995 in previous studies [b-Malmodin 2018a].
+- The main factors impacting activity level forward will be 5G deployment, 4G development, removal of old equipment, growth in population and expansion of IoT.
+
+NOTE – Between 1995 and 2015, Internet data traffic grew 1 million times, while subscriptions grew 10 times; energy and CO2e grew about 3 times [b-Malmodin 2018c]. By 2030, mobile data traffic is expected to increase 60–140 times.
+
+##### IV.1.1.3 Electricity usage
+
+In summary, the footprint of mobile operation is expected to increase somewhat until 2023, mainly because of the ongoing establishment of 5G. However, usage of 2G or 3G networks is assumed to decline.
+
+Neither Appendix III nor [b-Malmodin 2018a] present electricity numbers allocated to 2G, 3G, 4G and 5G separately. However, as these access technologies are in different stages of their technology life cycle, it would be important to do so to understand how the overall mobile networks could develop over the coming decade.
+
+NOTE – Potentially 6G could enter the scene before 2030, but as it has not yet been defined, it cannot be included in the scenario and is anyway believed to have only a limited impact on the sub-sector footprint by 2030.
+
+Overall historical energy consumption was based on estimates for 2007, 2010 and 2015 from [b-Malmodin 2010], [b-Malmodin 2013], [b-Malmodin 2018a] and [b-Malmodin 2018c], and the values include both grid electricity and company electricity generation (diesel, etc.). In addition, development until 2019 was estimated using the same data sources and method. The historical development of overall subscriptions was based on [b-ITU 2005–2019] data for specific years and energy performance is assumed to continue to develop in line with past history.
+
+To allocate overall energy usage to the different access technologies, the historical footprints for 2007, 2010 and 2015 based on [b-Malmodin 2010], [b-Malmodin 2013], [b-Malmodin 2018a] and [b-Malmodin 2018c] were combined with historical sales statistics of Ericsson and its historical estimated market shares to arrive at an energy usage allocation between the different access standards of the installed base year-by-year.
+
+See Figure IV.3.
+
+
+
+Mobile networks electricity consumption (and total human subscriptions)
+
+180 160 140 120 100 80 60 40 20 0
+
+TWh
+
+Total human subscriptions (Right axis, billions)
+
+Small cells
+
+Forecast from here
+
+5G 45%
+
+4G 36%
+
+3G
+
+2G
+
+1G and 2G
+
+Overhead (Offices, stores etc.)
+
+7%
+
+12%
+
+2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030
+
+Overhead 1G and 2G 3G 4G 5G Small cells Subscriptions (Human, billions)
+
+L.1470(20)\_FIV.3
+
+Figure IV.3: Mobile networks electricity consumption (and total human subscriptions). A dual-axis chart showing electricity consumption in TWh (left axis, 0-180) and total human subscriptions in billions (right axis, 0-10) from 2005 to 2030. The chart is divided into historical data (2005-2018) and a forecast period (2019-2030). Electricity consumption is broken down by technology: Overhead (Offices, stores etc.), 1G and 2G, 3G, 4G, 5G, and Small cells. Subscriptions are shown as a black line. The 2030 electricity consumption breakdown is: 5G (45%), 4G (36%), 1G and 2G (12%), and Overhead (7%).
+
+Figure IV.3 – Mobile networks electricity consumption allocated to 2G, 3G, 4G and 5G
+
+This scenario assumes that the majority of operators in the USA, Europe and China decommission their 2G equipment by 2030, so that only 20% of 2G electricity consumption remains. This is a lagged
+
+version of the anticipated development of subscriptions, as it is based on [b-Ericsson MR 2019] and extrapolated between 2024 and 2030. The lag is due to the assumption that networks are decommissioned with some delay compared to the reduction in number of subscriptions.
+
+For 3G, the scenario considers decommissioning in line with every second 3G site in the USA, Europe and China – in some markets 3G is actually decommissioned as fast as 2G, but this scenario more conservatively reflects a slower development.
+
+4G is expected to grow until 2025 and then remain flat (in line with [b-Ericsson MR 2019] until 2024, see Figure IV.1).
+
+Any further densification is assumed to be counteracted by the modernization of old equipment.
+
+5G is assumed to grow until 2030, and in the end consume almost 30% more electricity than any former standard. Future estimates of 5G energy consumption stretch from 50% (Ericsson estimate) of 4G, to 200% (Orange estimate) of 4G –130% has been chosen in this scenario as reasonable trade off.
+
+This scenario outlines one potential development that, together with decarbonization of the ES, supports a 1.5°C trajectory. In reality, a 1.5°C trajectory can be implemented in different ways. Another way to reach the same development for the energy usage would be a combination of decommissioning and modernization measures, such as the use of multi-standard base-stations, increased usage of power-saving features or more aggressive decommissioning of older systems.
+
+NOTE –Decommissioning of 2G and 3G has already been announced by many operators, see, for example, [b-Olivia], [b-Telia], [b-IEEE Com Soc] and [b-Comms Update].
+
+##### **IV.1.1.4 Overhead**
+
+Offices, stores and travel are assumed to remain at the same level. Some growth in number of subscriptions is expected, but this is likely to be counteracted by efficiency and automation measures to keep down costs and online purchases impacting number of shops. As overheads are a small share of the overall footprint, this has not been modelled in detail in this scenario.
+
+##### **IV.1.1.5 Embodied emissions**
+
+- Embodied emissions are calculated to remain at 2 kg CO2 e/subscription and year based on [b-Malmodin 2018a], [b-Malmodin 2018b] in line with clause III.2.2.
+- Overall the emissions related to manufacturing of mobile network equipment is expected to increase somewhat as 5G is rolled out. However, new access technologies often reuse existing sites, leading to a lower environmental impact compared to building a new site. Building on a used site results in about two-thirds of emissions of building a new site. The site factor depends on the assumed usage time. Here the site operation time is estimated to be 20 years.
+
+##### **IV.1.1.6 Resulting trajectory (mobile network development without further use of renewables)**
+
+See Figure IV.4.
+
+
+
+Mobile networks
+
+The figure consists of two stacked area charts. The top chart includes seven categories, while the bottom chart includes six, omitting the 'Mobile networks total electricity T&D supply chain' category. The y-axis for both is 'Mt CO2 e' ranging from 0 to 140. The x-axis shows years from 2015 to 2030.
+
+**Data for Top Chart (Approximate Mt CO2 e):**
+
+| Category | 2015 | 2020 | 2025 | 2030 |
+|---------------------------------------------------------------------|------|------|------|------|
+| Mobile networks total electricity T&D supply chain (Yellow) | 15 | 18 | 20 | 20 |
+| Mobile networks electricity consumption (Orange) | 50 | 55 | 65 | 70 |
+| Mobile networks own electricity generation (Red) | 25 | 25 | 22 | 20 |
+| Mobile networks operator's overhead - electricity (Light Blue) | 5 | 5 | 5 | 5 |
+| Mobile networks operator's overhead + excl. electricity (Dark Blue) | 5 | 5 | 5 | 5 |
+| Mobile networks manufacturers (Grey) | 5 | 7 | 8 | 10 |
+| Mobile networks supply chain (Dark Grey) | 10 | 10 | 10 | 10 |
+
+**Data for Bottom Chart (Approximate Mt CO2 e):**
+
+| Category | 2015 | 2020 | 2025 | 2030 |
+|---------------------------------------------------------------------|------|------|------|------|
+| Mobile networks electricity consumption (Orange) | 50 | 55 | 65 | 70 |
+| Mobile networks own electricity generation (Red) | 25 | 25 | 22 | 20 |
+| Mobile networks operator's overhead - electricity (Light Blue) | 5 | 5 | 5 | 5 |
+| Mobile networks operator's overhead + excl. electricity (Dark Blue) | 5 | 5 | 5 | 5 |
+| Mobile networks manufacturers (Grey) | 5 | 7 | 8 | 10 |
+| Mobile networks supply chain (Dark Grey) | 10 | 10 | 10 | 10 |
+
+Two stacked area charts showing the mobile network footprint in Mt CO2e from 2015 to 2030. The top chart includes 'Mobile networks total electricity T&D supply chain' (yellow), while the bottom chart does not. Both charts show a general increase in total footprint over time, driven primarily by electricity consumption and supply chain factors.
+
+L.1470(20)\_FIV.4
+
+**Figure IV.4 – Mobile network footprint 2015–2020 (with unchanged grid emission factor)**
+
+#### IV.1.2 Fixed networks
+
+##### IV.1.2.1 Boundaries
+
+The boundaries are defined in accordance with Annex A of [ITU-T L.1450]:
+
+- wireline networks include first list items 1), 3), 5) and 6) of clause A.3 of [ITU-T L.1450];
+- it further includes support goods (second list items 1), 2) and 3) of clause A.3 of [ITU-T L.1450]);
+- operator support activities are included and shown separately;
+- operator data centres are excluded as they have been allocated to data centres;
+- boundary towards wireless networks made after mobile core, and all common network functions are allocated to the fixed networks sub-sector;
+- end-user goods owned by operators have been allocated to the category end-user goods.
+
+##### IV.1.2.2 Activity level
+
+- Number of subscriptions refers to number of lines.
+
+- This includes compound telephony and fixed broadband (VoIP excluded, although included in energy and carbon).
+- Sources: [b-ITU 2005–2019] data to 2018, trajectories to 2022–23 from [b-OMDIA 2020b], after that an extrapolation was made.
+- Historical geographical distribution is considered in accordance with developments seen from 1995 in previous studies [b-Malmodin 2018b].
+- Development between 2015 and 2030 is expected to go from 1.85 billion to 1.9 billion subscriptions as fixed telephony subscription are assumed to decrease by 50% and fixed broadband subscriptions to increase by a factor of 1.8.
+- Fixed data traffic is expected to increase 18–36 times.
+
+##### IV.1.2.3 Electricity usage
+
+For fixed networks, it is assumed that the kilowatt hour per subscription (line) value will stay flat in line with the current trend. Historical development has been associated with increased capacity per line with maintained electricity consumption.
+
+Current electricity usage according to [b-Malmodin 2018b] for reference:
+
+- older modem + router setup: 15–20 W;
+- fixed access node: 3 W (1–5 W);
+- media converter: 3 W (1–5 W);
+- new gateway: 10–15 W;
+- Swedish transmission/transport: 1.5 W per fixed BB (allocated)
+- Swedish core network: about 1 W per fixed BB (allocated);
+- CPE dominates electricity: 15 W (10–30 W);
+- network is about 5 W on average and only about 1 W in the core varies slightly with data.
+
+As the kilowatt hour per line value is assumed to stay flat, the changes in overall electricity usage is based on the expected change in number of subscriptions.
+
+Historical development has been tracked based on [b-ITU 2005–2019] data and the trends have been extrapolated.
+
+The future trend for broadband connections considers [b-Point Topic], which has estimated that there will be 1.1 billion broadband connections in 2022 and 1.2 billion in 2025. As their historical values are lower than those of [b-ITU 2005–2019], 1.3 billion in 2025 and 1.4 billion in 2030 have been assumed.
+
+The assumed decommissioning of traditional telephony (PSTN) assumes an extrapolation of the current trend, where a decline is seen in mature markets – a development which is expected to expand in the future.
+
+See Figure IV.5.
+
+
+
+| Year | Overhead (TWh) | Telephony (PSTN) (TWh) | Broadband access (TWh) | Core (TWh) | Total (TWh) |
+|------|----------------|------------------------|------------------------|------------|-------------|
+| 2015 | ~10 | ~45 | ~20 | ~20 | ~95 |
+| 2018 | ~10 | ~40 | ~30 | ~25 | ~105 |
+| 2020 | ~10 | ~35 | ~40 | ~25 | ~110 |
+| 2025 | ~10 | ~30 | ~50 | ~25 | ~115 |
+| 2030 | ~10 | ~25 | ~60 | ~25 | ~120 |
+
+Summary data on the right side of the chart:
+
+- Core: +60% vs 2015
+- Broadband access: +95% vs 2015
+- Telephony (PSTN): -50% vs 2015
+
+Legend: Overhead (dark pink), Telephony (medium pink), Broadband (light pink), Core (very light pink).
+
+Stacked area chart titled 'Fixed networks electricity consumption' showing TWh from 2015 to 2030. The chart is divided into four categories: Overhead (Offices, stores etc.), Telephony (PSTN), Broadband access, and Core. The Y-axis ranges from 0 to 120 TWh. The X-axis shows years from 2015 to 2030. A vertical line at 2018 indicates the start of the forecast. The chart shows a significant decrease in Telephony (PSTN) consumption, a sharp increase in Broadband access, and a relatively stable Core consumption. Overhead consumption remains relatively flat. Summary data on the right: Core +60% vs 2015, Broadband access +95% vs 2015, Telephony (PSTN) -50% vs 2015.
+
+L.1470(20)\_FIV.5
+
+**Figure IV.5 – Fixed networks electricity consumption**
+
+In summary, the overall fixed access footprint is expected to decrease as the old PSTN, which is a more energy intensive system, is used less. In fact, an old telephony line consumes as much as a modern fixed broadband connection [b-Malmodin 2018c].
+
+In addition to access networks, the fixed network sub-sector also includes core, transport and transmission equipment. In Sweden, a highly ICT mature country, the core network represents only about 6% of the ICT footprint, while core, transmission and transport networks together make up 15% [b-Malmodin, Lundén 2016].
+
+The fixed networks have been designed to be on all the time and the load (data) adaptation is limited. However, the core network footprint (6% of the ICT footprint) to some extent correlates with the amount of data used, but this has only a minor impact on the fixed network footprint.
+
+##### **IV.1.2.4 Embodied emissions**
+
+Calculated as 4kg CO2 e/subscription and year based on [b-Malmodin 2018a].
+
+Overall manufacturing is expected to decrease.
+
+##### **IV.1.2.5 Resulting trajectory (ICT development without further use of renewables)**
+
+See Figure IV.6.
+
+
+
+**Fixed networks (Top Chart)**
+
+| Year | Fixed networks supply chain | Fixed networks manufacturers | Fixed networks operator's overhead + excl. electricity | Fixed networks operator's overhead - electricity | Fixed networks electricity consumption | Fixed networks total electricity T&D supply chain | Total (Mt CO 2 e) |
+|------|-----------------------------|------------------------------|--------------------------------------------------------|--------------------------------------------------|----------------------------------------|---------------------------------------------------|------------------------------|
+| 2015 | ~5 | ~3 | ~2 | ~2 | ~45 | ~10 | ~67 |
+| 2020 | ~5 | ~3 | ~2 | ~2 | ~48 | ~10 | ~70 |
+| 2025 | ~5 | ~3 | ~2 | ~2 | ~48 | ~10 | ~70 |
+| 2030 | ~5 | ~3 | ~2 | ~2 | ~45 | ~10 | ~67 |
+
+
+
+**Fixed networks (Bottom Chart)**
+
+| Year | Fixed networks supply chain | Fixed networks manufacturers | Fixed networks operator's overhead + excl. electricity | Fixed networks operator's overhead - electricity | Fixed networks electricity consumption | Total (Mt CO 2 e) |
+|------|-----------------------------|------------------------------|--------------------------------------------------------|--------------------------------------------------|----------------------------------------|------------------------------|
+| 2015 | ~5 | ~3 | ~2 | ~2 | ~45 | ~57 |
+| 2020 | ~5 | ~3 | ~2 | ~2 | ~48 | ~60 |
+| 2025 | ~5 | ~3 | ~2 | ~2 | ~48 | ~60 |
+| 2030 | ~5 | ~3 | ~2 | ~2 | ~45 | ~57 |
+
+Two stacked area charts showing the fixed network footprint in Mt CO2e from 2015 to 2030. The top chart includes 'Fixed networks total electricity T&D supply chain' (yellow), while the bottom chart does not. Both charts show a relatively stable footprint, with 'Fixed networks electricity consumption' (orange) being the largest contributor. Other categories include 'Fixed networks operator's overhead - electricity' (light blue), 'Fixed networks operator's overhead + excl. electricity' (dark blue), 'Fixed networks manufacturers' (light grey), and 'Fixed networks supply chain' (dark grey).
+
+L.1470(20)\_FIV.6
+
+**Figure IV.6 – Fixed network footprint 2015–2030 (with unchanged grid emission factor)**
+
+#### IV.1.3 Data centre
+
+##### IV.1.3.1 Boundaries
+
+- In line with Annex A of [ITU-T L.1450], this category includes all data centres – from "in closets" to hyperscale – but excludes enterprise networks, which are assigned to a separate category.
+- Operator support activities are included as separate categories.
+- ICT network operators and ICT manufacturers have large data centres that are included here.
+
+##### IV.1.3.2 Activity level
+
+- The number of servers in use globally is based on [b-IDC 7] for all kinds of server models. Data exist up to 2018; from 2019, extrapolations estimate the number of servers will increase from 43 million to 55 million between 2015 and 2030.
+- The amount of data or subscriptions differ by many orders of magnitude between different data centres and are therefore not used to estimate future electricity usage.
+- Actual sales statistics reflect regional variations in server types in line with the baseline.
+- Data traffic is assumed to increase 18–36 times.
+
+##### IV.1.3.3 Electricity usage
+
+Existing trends that impact electricity usage include consolidation, virtualization, hardware development, cloudification and PUE development.
+
+[b-IEA Digitalization] assumes 3% electricity growth for data centre electricity usage globally yearly 2014–2021.
+
+The typical electricity consumption per unit is expected to remain quite flat as capacity per unit increases. At the same time, PUE is assumed to decrease. According to IEA, PUE = 1.8 for 2015, and Intel has estimated a value of 1.7 for 2019. Due to cloudification, we assume 1.6 for 2020 and 1.4 for 2030.
+
+Moreover, it is assumed that shipping of high-performance servers will increase, but shipping of volume servers is assumed to decline. [b-Cisco] and [b-IDC 7] estimate that in 2030, around 90% of data will be handled by less than 1 000 data centres worldwide.
+
+Weighing these trends together, a roughly flat development of overall data centre energy usage is assumed.
+
+##### IV.1.3.4 Embodied emissions
+
+- Embodied emissions are calculated as 10% of total data centre emissions from electricity usage based on [b-Google 2016a], [b-Google 2016b]. The factor includes the conversion from electricity to carbon emissions.
+
+The resulting trajectory (ICT development without further use of renewables) is plotted in Figure IV.7.
+
+
+
+The figure consists of two stacked area charts, both titled "Data centres". The y-axis for both is "Mt CO2 e" ranging from 0 to 140. The x-axis for both is years: 2015, 2020, 2025, and 2030.
+
+**Top Chart Legend:**
+
+- Data centre total electricity T&D supply chain (Yellow)
+- Data centre electricity consumption (Orange)
+- Data centre operator's overhead - electricity (Light Blue)
+- Data centre operator's overhead + (electricity) (Dark Blue)
+- Data centre manufacturers (Grey)
+- Data centre supply chain (Dark Grey)
+
+**Bottom Chart Legend:**
+
+- Data centre electricity consumption (Orange)
+- Data centre operator's overhead - (electricity) (Light Blue)
+- Data centre operator's overhead + excl. electricity (Dark Blue)
+- Data centre manufacturers (Grey)
+- Data centre supply chain (Dark Grey)
+
+**Data Trends:**
+
+- 2015:** Total emissions are approximately 140 Mt CO2 e. The largest component is electricity consumption (orange), followed by the T&D supply chain (yellow).
+- 2020:** There is a noticeable dip in total emissions to around 125 Mt CO2 e. The electricity consumption component decreases, while the T&D supply chain component increases.
+- 2025:** Emissions begin to rise again, reaching approximately 135 Mt CO2 e.
+- 2030:** Total emissions reach approximately 140 Mt CO2 e. The electricity consumption component is the dominant factor.
+
+Two stacked area charts showing data centre footprints from 2015 to 2030. The top chart includes 'Data centre total electricity T&D supply chain' (yellow), 'Data centre electricity consumption' (orange), 'Data centre operator's overhead - electricity' (light blue), 'Data centre operator's overhead + (electricity)' (dark blue), 'Data centre manufacturers' (grey), and 'Data centre supply chain' (dark grey). The bottom chart is similar but replaces 'Data centre total electricity T&D supply chain' with 'Data centre electricity consumption' (orange), 'Data centre operator's overhead - (electricity)' (light blue), 'Data centre operator's overhead + excl. electricity' (dark blue), 'Data centre manufacturers' (grey), and 'Data centre supply chain' (dark grey). Both charts show a slight dip in total emissions around 2020, followed by a rise towards 2030.
+
+L.1470(20)\_FIV.7
+
+Figure IV.7 – Data centre footprint 2015–2030 (with unchanged grid emission factor)
+
+#### IV.1.4 Enterprise networks
+
+##### IV.1.4.1 Boundaries
+
+- This is considered as a separate category, which includes routers and other intranet equipment.
+
+##### IV.1.4.2 Activity level
+
+- Business use of PCs is estimated from [b-IDC 1541] and [b-Gartner]. This information is combined with estimated amounts of PCs per active LAN port in accordance with [b-Malmodin 2018a].
+- [b-IDC 1541] and [b-Gartner] statistics indicate that PCs for enterprise networks increased until 2015, but development thereafter is uncertain.
+- Actual sales statistics reflect regional variations in server types in line with the baseline.
+
+##### IV.1.4.3 Electricity usage
+
+- Electricity usage is based on [b-Malmodin 2018a]. The historical trend has been a fast decrease of electricity need per PC per LAN port.
+- An assumed small increase in active LAN-PCs correlating with more enterprise network equipment is assumed to be countered by energy efficiency improvements resulting in flat development of total electricity consumption.
+- Shipment volumes are assumed to stay flat.
+- Typically 0.5 W/port for high-definition (HD) video – 1 W/Gb – in total 3 W/workplace PC in line with baseline [b-Malmodin 2018 a].
+- Conference equipment etc. adds approximately 1 W/PC.
+
+##### IV.1.4.4 Embodied emissions
+
+- Embodied emissions are calculated as 10% of total emissions in line with baseline. The factor includes the conversion from electricity to carbon emissions.
+
+##### IV.1.4.5 Resulting trajectory (ICT development without further use of renewables)
+
+See Figure IV.8.
+
+
+
+The figure consists of two stacked bar charts, both titled 'Enterprise networks'. The y-axis for both is 'Mt CO2 e' ranging from 0 to 100. The x-axis for both shows the years 2015, 2020, 2025, and 2030. The top chart includes three categories: 'Enterprise networks total electricity T&D supply chain' (yellow), 'Enterprise networks operation' (orange), and 'Enterprise networks manufacturers electricity' (blue). The bottom chart includes two categories: 'Enterprise networks operation' (orange) and 'Enterprise networks manufacturers electricity' (blue). Both charts show a flat trend over the period, with the total footprint remaining at approximately 15 Mt CO2 e.
+
+| Year | Manufacturers Electricity (Mt CO 2 e) | Operation (Mt CO 2 e) | Total (Mt CO 2 e) |
+|------|--------------------------------------------------|----------------------------------|------------------------------|
+| 2015 | ~1.5 | ~13.5 | ~15 |
+| 2020 | ~1.5 | ~13.5 | ~15 |
+| 2025 | ~1.5 | ~13.5 | ~15 |
+| 2030 | ~1.5 | ~13.5 | ~15 |
+
+Two stacked bar charts showing the enterprise network footprint in Mt CO2e from 2015 to 2030. The top chart includes 'Enterprise networks total electricity T&D supply chain' (yellow), 'Enterprise networks operation' (orange), and 'Enterprise networks manufacturers electricity' (blue). The bottom chart includes 'Enterprise networks operation' (orange) and 'Enterprise networks manufacturers electricity' (blue). Both charts show a flat trend over the period.
+
+Figure IV.8 – Enterprise network footprint 2015–2030 (with unchanged grid emission factor)
+
+#### IV.1.5 End-user goods
+
+##### IV.1.5.1 Boundaries
+
+- Boundaries are based on clause A.4 of [ITU-T L.1450], and includes CPE (modems, gateways), fixed phones (PSTN + VoIP), PCs (including desktops, laptops, peripherals and displays), mobile devices (including mobile phones, smartphones, tablets), M2M (including smart meters, surveillance cameras, payment terminals, projectors, public displays, wearables).
+- In the next iteration of this work all IoT should be included.
+
+##### IV.1.5.2 Activity levels
+
+- It is assumed that 13 billion devices will expand to 20 billion between 2015 and 2030. This includes an increase of mobile device numbers from 7.8 billion to 10 billion, and PCs going from 1.7 billion to 1.5 billion (in 2020) and then back to 1.7 billion in 2030. M2M device numbers are according to [b-Malmodin 2018a].
+- The number of actual devices in active use is estimated from sales statistics and estimated operational lifetime as described in clause III.2.5. Operational lifetime is also estimated in accordance with Appendix III.
+- Sales statistics used when available (see Table III.5 for details), with extrapolations for the future.
+ - Regional distribution in accordance with current sales.
+ - Mobile devices scaled based on subscriptions, CPE based on number of lines.
+
+##### IV.1.5.3 Electricity usage
+
+Electricity usage is assumed to scale with sales. The following development is assumed.
+
+- CPE: the kilowatt hour per average unit value is assumed to reduce by 35% per device in the period 2015–2030 due to efficiency improvements (based on an observed 2015–2018 reduction of 10%), which means a change from 12.4 W on average in 2015 per connected household or premises based on [b-Malmodin 2018a] to 8.1 W on average in 2030.
+- Fixed phones: no energy efficiency improvements are assumed.
+- PCs: lower share of desktops, energy efficiency improvements, gaming PCs have a small but growing share.
+- PC (including screens): the average kilowatt hour per unit value is estimated to have reduced by 13% in the period 2015–2018 based on a further shift from desktop to laptop. For 2018–2030, no reduction per PC is assumed for each type, but any energy efficiency improvements are assumed to be used for other performance improvements.
+- Mobile: a larger share of smartphones is assumed, which means that the kilowatt hour per average unit value is assumed to increase by 56% due to increased usage and larger size of mobiles.
+- Other including M2M:
+ - the kilowatt hour per average unit value is assumed to stay flat in line with baseline;
+ - fast increase in the number of surveillance cameras to 2020 countered somewhat by energy efficiency improvements;
+ - M2M after 2020 are forecast to be dominated by wearables;
+ - Steady build-up of smart meters and payment terminals.
+
+##### IV.1.5.4 Embodied emissions
+
+- Current assumption is that embodied CO2e value for all end-user devices will remain roughly constant (i.e., that embodied emissions and lifetimes are kept flat), but there is a huge
+
+potential for ICT manufacturers to also use renewables in the future as a substantial part of the embodied emissions emerge from electricity used in different processes. This potential needs to be estimated more thoroughly.
+
+- Embodied emissions and lifetime are kept unchanged compared to the baseline
+
+##### IV.1.5.5 Resulting trajectory (ICT development without further use of renewables)
+
+See Figures IV.9 and IV.10.
+
+
+
+| Year | CPE | PCs | Mobile | Other | IoT + scenario | Total |
+|------|-----|-----|--------|-------|----------------|-------|
+| 2015 | 120 | 180 | 10 | 10 | 0 | 320 |
+| 2020 | 130 | 140 | 20 | 60 | 10 | 360 |
+| 2025 | 140 | 140 | 30 | 70 | 40 | 420 |
+| 2030 | 140 | 150 | 40 | 80 | 70 | 480 |
+
+Stacked bar chart titled 'User devices' showing emissions in Mt CO2e for the years 2015, 2020, 2025, and 2030. The chart is divided into five categories: CPE (blue), PCs (orange), Mobile (grey), Other (yellow), and IoT + scenario (dark blue). The total emissions show a steady increase over the period, with CPE and PCs being the largest contributors.
+
+L.1470(20)\_FIV.9
+
+Figure IV.9 – Devices (Mt CO2 e)
+
+
+
+**Figure IV.10 (Top Chart): User devices footprint 2015–2030 (with unchanged grid emission factor)**
+
+| Year | User devices supply chain non-electricity | User devices manufacturers (non-electricity) | User devices supply chain, electricity | User devices manufacturers electricity | User devices operation | User devices total electricity T&D supply chain | Total |
+|------|-------------------------------------------|----------------------------------------------|----------------------------------------|----------------------------------------|------------------------|-------------------------------------------------|-------|
+| 2015 | ~40 | ~30 | ~20 | ~70 | ~170 | ~70 | ~400 |
+| 2020 | ~40 | ~30 | ~20 | ~80 | ~230 | ~100 | ~500 |
+| 2025 | ~40 | ~30 | ~20 | ~90 | ~280 | ~130 | ~590 |
+| 2030 | ~40 | ~30 | ~20 | ~100 | ~330 | ~160 | ~680 |
+
+**Figure IV.10 (Bottom Chart): User devices footprint 2015–2030 (without electricity T&D supply chain)**
+
+| Year | User devices supply chain non-electricity | User devices manufacturers (non-electricity) | User devices supply chain, electricity | User devices manufacturers electricity | User devices operation | Total |
+|------|-------------------------------------------|----------------------------------------------|----------------------------------------|----------------------------------------|------------------------|-------|
+| 2015 | ~40 | ~30 | ~20 | ~70 | ~170 | ~330 |
+| 2020 | ~40 | ~30 | ~20 | ~80 | ~230 | ~400 |
+| 2025 | ~40 | ~30 | ~20 | ~90 | ~280 | ~460 |
+| 2030 | ~40 | ~30 | ~20 | ~100 | ~330 | ~520 |
+
+Two stacked area charts showing the user devices footprint in Mt CO2e from 2015 to 2030. The top chart includes the electricity T&D supply chain, while the bottom chart excludes it. Both show a general increase in total footprint over time, driven primarily by user device operation and manufacturers' electricity use.
+
+**Figure IV.10 – User devices footprint 2015–2030 (with unchanged grid emission factor)**
+
+### IV.2 Step 2: ICT and grid development
+
+#### IV.2.1 ICT sector and sub-sector trajectories
+
+While the focus of clause IV.1 was on the development of the ICT sector, this clause adds the development of grid electricity based on the grid trajectory for 1.5°C of the SBT initiative. For emission factors, see clause 6.3.
+
+Figures IV.11 and IV.12 both reflect a situation where the SBT initiative trajectory is added on top of the anticipated ICT development from step 1. Figure IV.12 excludes grid ES chain and distribution losses in line with company accounting frameworks, Figure IV.11 includes them for a more holistic understanding of the footprint of the ICT sector in line with LCA practice.
+
+See Figures IV.13 to IV.17.
+
+
+
+| Year | Mobile networks | Fixed networks | Data centres | User devices | Enterprises networks | Total |
+|------|-----------------|----------------|--------------|--------------|----------------------|-------|
+| 2015 | 110 | 70 | 140 | 410 | 10 | 740 |
+| 2020 | 110 | 60 | 130 | 380 | 10 | 690 |
+| 2025 | 100 | 50 | 110 | 320 | 10 | 590 |
+| 2030 | 80 | 40 | 90 | 220 | 10 | 440 |
+
+Stacked area chart titled 'Including T&D losses and fuel supply' showing ICT sector CO2 emissions from 2015 to 2030. The y-axis is Mt CO2e (0-1000). The x-axis shows years (2015, 2020, 2025, 2030). The legend includes: Enterprises networks (red), User devices (yellow), Data centres (green), Fixed networks (light blue), and Mobile networks (dark blue). Total emissions decrease from approximately 740 Mt CO2e in 2015 to 380 Mt CO2e in 2030.
+
+
+
+| Year | ICT's own development (Mt CO 2 e) | 1.5°C trajectory (Mt CO 2 e) |
+|------|----------------------------------------------|-----------------------------------------|
+| 2015 | 740 | 740 |
+| 2020 | 760 | 680 |
+| 2025 | 800 | 520 |
+| 2030 | 820 | 380 |
+
+Line chart titled 'Overall footprint including electricity transmission and distribution losses and fuel supply chain' comparing two trajectories from 2015 to 2030. The y-axis is Mt CO2e (0-1000). The x-axis shows years (2015, 2020, 2025, 2030). The legend includes: ICT's own development with unchanged electricity emission factor (blue line) and 1.5°C trajectory (green line). The 1.5°C trajectory shows a significant decrease in emissions over the period, while the other trajectory shows a slight increase.
+
+L.1470(20)\_FIV.11
+
+**Figure IV.11 – Overall ICT sector 1.5°C trajectory for the period 2015–2030 including electricity supply chain and transmission and distribution losses (perspective A)**
+
+
+
+**Excluding T&D losses and fuel supply**
+
+| Year | Mobile networks | Fixed networks | Data centres | User devices | Enterprises networks | Total |
+|------|-----------------|----------------|--------------|--------------|----------------------|-------|
+| 2015 | ~100 | ~50 | ~120 | ~350 | ~10 | ~630 |
+| 2020 | ~110 | ~55 | ~130 | ~380 | ~15 | ~690 |
+| 2025 | ~120 | ~60 | ~140 | ~410 | ~20 | ~750 |
+| 2030 | ~130 | ~65 | ~150 | ~440 | ~25 | ~810 |
+
+Stacked area chart titled 'Excluding T&D losses and fuel supply' showing ICT sector emissions in Mt CO2e from 2015 to 2030. The chart is broken down into five categories: Mobile networks (blue), Fixed networks (light blue), Data centres (green), User devices (yellow), and Enterprises networks (red). Total emissions show a steady increase over the period.
+
+
+
+**Overall footprint excluding electricity transmission and distribution losses and fuel supply chain**
+
+| Year | ICT's own development with unchanged electricity emission factor (Mt CO 2 e) | 1.5°C trajectory (Mt CO 2 e) |
+|------|-----------------------------------------------------------------------------------------|-----------------------------------------|
+| 2015 | ~620 | ~620 |
+| 2020 | ~630 | ~580 |
+| 2025 | ~660 | ~450 |
+| 2030 | ~690 | ~320 |
+
+Line chart titled 'Overall footprint excluding electricity transmission and distribution losses and fuel supply chain' comparing two scenarios from 2015 to 2030. The 'ICT's own development with unchanged electricity emission factor' (blue line) shows a slight increase in emissions, while the '1.5°C trajectory' (green line) shows a significant decrease.
+
+L.1470(20)\_FIV.12
+
+**Figure IV.12 – Overall ICT sector 1.5°C trajectory, excluding electricity supply chain and transmission and distribution losses (perspective B)**
+
+
+
+**Mobile networks**
+
+| Category | 2015 | 2020 | 2025 | 2030 |
+|---------------------------------------------------------|------|------|------|------|
+| Mobile networks total electricity T&D supply chain | 15 | 12 | 10 | 8 |
+| Mobile networks electricity consumption | 50 | 45 | 35 | 25 |
+| Mobile networks own electricity generation | 25 | 22 | 20 | 18 |
+| Mobile networks operator's overhead - electricity | 5 | 4 | 3 | 2 |
+| Mobile networks operator's overhead + excl. electricity | 5 | 5 | 5 | 5 |
+| Mobile networks manufacturers | 5 | 5 | 5 | 5 |
+| Mobile networks supply chain | 10 | 10 | 10 | 10 |
+
+
+
+**Mobile networks (SBT trajectory)**
+
+| Category | 2015 | 2020 | 2025 | 2030 |
+|---------------------------------------------------------|------|------|------|------|
+| Mobile networks electricity consumption | 50 | 42 | 30 | 20 |
+| Mobile networks own electricity generation | 25 | 22 | 20 | 18 |
+| Mobile networks operator's overhead - electricity | 5 | 4 | 3 | 2 |
+| Mobile networks operator's overhead + excl. electricity | 5 | 5 | 5 | 5 |
+| Mobile networks manufacturers | 5 | 5 | 5 | 5 |
+| Mobile networks supply chain | 10 | 10 | 10 | 10 |
+
+
+
+**Mobile networks**
+
+| Scenario | 2015 | 2020 | 2025 | 2030 |
+|--------------------------------|------|------|------|------|
+| 1.5°C trajectory (red line) | 100 | 95 | 80 | 60 |
+| Reference scenario (blue line) | 100 | 105 | 112 | 115 |
+
+L.1470(20)\_FIV.13
+
+Three charts showing mobile network CO2e emissions from 2015 to 2030. Chart (a) is a stacked area chart of detailed emissions. Chart (b) is a stacked area chart of the SBT trajectory. Chart (c) is a line graph comparing a 1.5°C trajectory with a reference scenario.
+
+**Figure IV.13 – Mobile networks 1.5°C trajectory for the period 2015–2030: a) detailed trajectory including electricity supply chain and transmission and distribution losses; b) detailed trajectory electricity supply chain and transmission and distribution losses; c) resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+
+
+**Figure IV.14 – Fixed networks 1.5°C trajectory for the period 2015–2030:**
+
+**a) detailed trajectory including electricity supply chain and transmission and distribution losses;**
+
+**b) detailed trajectory electricity supply chain and transmission and distribution losses;**
+
+**c) resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+L.1470(20)\_FIV.14
+
+Three stacked area charts showing fixed networks CO2e emissions from 2015 to 2030. Chart (a) shows a detailed trajectory with electricity supply chain and T&D losses. Chart (b) shows a similar trajectory but without T&D losses. Chart (c) shows a line graph comparing a 1.5°C trajectory (red line) with a reference scenario (blue line).
+
+
+
+**Figure IV.15 – Data centre 1.5°C trajectory for the period 2015–2030**
+
+**a) Detailed trajectory including electricity supply chain and transmission and distribution losses**
+
+| Year | Data centre supply chain (Mt CO 2 e) | Data centre manufacturers (Mt CO 2 e) | Data centre operator's overhead + excl. electricity (Mt CO 2 e) | Data centre operator's overhead - electricity (Mt CO 2 e) | Data centre electricity consumption (Mt CO 2 e) | Data centre total electricity T&D supply chain (Mt CO 2 e) |
+|------|-------------------------------------------------|--------------------------------------------------|----------------------------------------------------------------------------|----------------------------------------------------------------------|------------------------------------------------------------|-----------------------------------------------------------------------|
+| 2015 | ~15 | ~5 | ~5 | ~5 | ~90 | ~20 |
+| 2020 | ~15 | ~5 | ~5 | ~5 | ~85 | ~20 |
+| 2025 | ~15 | ~5 | ~5 | ~5 | ~70 | ~15 |
+| 2030 | ~15 | ~5 | ~5 | ~5 | ~50 | ~10 |
+
+**b) Detailed trajectory electricity supply chain and transmission and distribution losses**
+
+| Year | Data centre supply chain (Mt CO 2 e) | Data centre manufacturers (Mt CO 2 e) | Data centre operator's overhead + excl. electricity (Mt CO 2 e) | Data centre operator's overhead - electricity (Mt CO 2 e) | Data centre electricity consumption (Mt CO 2 e) |
+|------|-------------------------------------------------|--------------------------------------------------|----------------------------------------------------------------------------|----------------------------------------------------------------------|------------------------------------------------------------|
+| 2015 | ~15 | ~5 | ~5 | ~5 | ~90 |
+| 2020 | ~15 | ~5 | ~5 | ~5 | ~85 |
+| 2025 | ~15 | ~5 | ~5 | ~5 | ~70 |
+| 2030 | ~15 | ~5 | ~5 | ~5 | ~50 |
+
+**c) Resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+| Year | 1.5°C trajectory (Mt CO 2 e) (Red line) | Reference scenario (Mt CO 2 e) (Blue line) |
+|------|----------------------------------------------------|-------------------------------------------------------|
+| 2015 | ~140 | ~140 |
+| 2020 | ~125 | ~125 |
+| 2025 | ~100 | ~135 |
+| 2030 | ~80 | ~140 |
+
+L.1470(20)\_FIV.15
+
+Three stacked area charts (a, b, c) showing data centre CO2 emissions from 2015 to 2030. Chart (a) includes supply chain and T&D losses. Chart (b) shows electricity consumption and overheads. Chart (c) compares a 1.5°C trajectory (red line) with a reference scenario (blue line).
+
+**Figure IV.15 – Data centre 1.5°C trajectory for the period 2015–2030: a) detailed trajectory including electricity supply chain and transmission and distribution losses; b) detailed trajectory electricity supply chain and transmission and distribution losses; c) resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+
+
+| Year | Total (Chart a) | Operation (Chart a/b) | 1.5°C Trajectory (Chart c) | Reference (Chart c) |
+|------|-----------------|-----------------------|----------------------------|---------------------|
+| 2015 | ~400 | ~170 | ~330 | ~330 |
+| 2020 | ~380 | ~160 | ~320 | ~340 |
+| 2025 | ~280 | ~110 | ~250 | ~360 |
+| 2030 | ~210 | ~80 | ~180 | ~380 |
+
+**Figure IV.16 – User devices 1.5°C trajectory for the period 2015–2030: a) detailed trajectory including electricity supply chain and transmission and distribution losses; b) detailed trajectory electricity supply chain and transmission and distribution losses; c) resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+L.1470(20)\_FIV.16
+
+Three charts (a, b, c) showing CO2 emission trajectories for user devices from 2015 to 2030. Chart (a) and (b) are stacked area charts showing components like operation, manufacturing, and supply chain. Chart (c) is a line graph comparing a 1.5°C trajectory to a reference line.
+
+
+
+| Year | Manufacturers Electricity | Operation | T&D Supply Chain | Total |
+|------|---------------------------|-----------|------------------|-------|
+| 2015 | ~10 | ~3 | ~2 | ~15 |
+| 2020 | ~10 | ~3 | ~2 | ~15 |
+| 2025 | ~8 | ~3 | ~1 | ~12 |
+| 2030 | ~5 | ~2 | ~1 | ~8 |
+
+Stacked area chart titled 'Enterprise networks' showing Mt CO2e from 2015 to 2030. The y-axis ranges from 0 to 100. The chart includes three stacked components: 'Enterprise networks manufacturers electricity' (blue, bottom), 'Enterprise networks operation' (orange, middle), and 'Fixed networks total electricity T&D supply chain' (yellow, top). The total emissions show a slight downward trend from approximately 15 Mt CO2e in 2015 to about 5 Mt CO2e in 2030.
+
+
+
+| Year | Manufacturers Electricity | Operation | Total |
+|------|---------------------------|-----------|-------|
+| 2015 | ~10 | ~2 | ~12 |
+| 2020 | ~10 | ~2 | ~12 |
+| 2025 | ~8 | ~2 | ~10 |
+| 2030 | ~5 | ~1 | ~6 |
+
+Stacked area chart titled 'Enterprise networks' showing Mt CO2e from 2015 to 2030. The y-axis ranges from 0 to 100. The chart includes two stacked components: 'Enterprise networks manufacturers electricity' (blue, bottom) and 'Enterprise networks operation' (orange, top). The total emissions show a slight downward trend from approximately 12 Mt CO2e in 2015 to about 5 Mt CO2e in 2030.
+
+
+
+| Year | 1.5°C Trajectory (Red) | Reference Trajectory (Blue) |
+|------|------------------------|-----------------------------|
+| 2015 | ~15 | ~15 |
+| 2020 | ~12 | ~15 |
+| 2025 | ~8 | ~15 |
+| 2030 | ~5 | ~15 |
+
+Line chart titled 'Enterprise networks' showing Mt CO2e from 2015 to 2030. The y-axis ranges from 0 to 200. It features two lines: a red line representing the 1.5°C trajectory (decreasing from ~15 Mt CO2e in 2015 to ~5 Mt CO2e in 2030) and a blue line representing the reference trajectory (constant at ~15 Mt CO2e).
+
+L.1470(20)\_FIV.17
+
+**Figure IV.17 – Enterprise networks 1.5°C trajectory for the period 2015–2030: a) detailed trajectory including electricity supply chain and transmission and distribution losses; b) detailed trajectory electricity supply chain and transmission and distribution losses; c) resulting 1.5°C trajectory (red line) with sector development without improvements in electricity emission factor as a reference (blue line) – perspective B**
+
+#### IV.2.2 Trajectory details
+
+Tables IV.1 and IV.2 summarize the details of the overall sector and sub-sector trajectories and show one reasonable scenario for the decarbonization of the sector in line with 1.5°C. However, other scenarios may exist that represent the same overall emission reduction.
+
+As the ambition has been to explore opportunities for a decarbonization of the sector in line with 1.5°C, the main emphasis has been on electricity usage and its emission factors.
+
+Additional decarbonization of emissions that are not associated with electricity usage could come on top of those indicated in Tables IV.1 and IV.2. However, the main part of the ICT footprint is associated with the use of electricity, so such reductions are expected to be less significant and they might also be harder to achieve.
+
+**Table IV.1 – Trajectory including electricity supply chain and grid losses in line with LCA principles (perspective A)**
+
+| | CO 2 e emissions including electricity supply chain and grid losses (Mt CO 2 e) | | | |
+|-------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|------|------|------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Mobile networks | | | | |
+| Mobile network manufacturers (s1-s2) | 3 | 3 | 2 | 1 |
+| Mobile network manufacturers, T&D (s3) | 0.3 | 0.3 | 0.2 | 0.1 |
+| Mobile network manufacturers, electricity supply (s3) | 0.45 | 0.45 | 0.3 | 0.15 |
+| Mobile network operator overheads – electricity (s2) | 6.4 | 6.4 | 6.4 | 6.4 |
+| Mobile network operator overheads – excluding electricity (s1-s2) | 4 | 4 | 4 | 4 |
+| Mobile network own electricity generation (s1-s2) | 25 | 23 | 21 | 18 |
+| Mobile network electricity consumption (s2) | 48 | 46 | 35 | 21 |
+| Mobile network electricity consumption, T&D (s3) | 5.4 | 4.6 | 3.5 | 2.1 |
+| Mobile network electricity consumption, electricity supply (s3) | 8.2 | 6.9 | 5.3 | 3.2 |
+| Mobile network supply chain s3 | 12 | 12 | 12 | 12 |
+| Mobile network supply chain, T&D (s3) | 0.75 | 0.75 | 0.75 | 0.75 |
+| Mobile network supply chain, electricity supply (s3) | 1.5 | 1.5 | 1.5 | 1.5 |
+| Fixed networks | | | | |
+| Fixed network manufacturers (s1-s2) | 1 | 1 | 0.7 | 0.3 |
+| Fixed network manufacturers, T&D (s3) | 0.1 | 0.1 | 0.07 | 0.03 |
+| Fixed network manufacturers, electricity supply (s3) | 0.15 | 0.15 | 0.1 | 0.05 |
+| Fixed network operator overheads – electricity (s2) | 3.2 | 3.2 | 3.2 | 3.2 |
+| Fixed network operator overheads – excluding electricity (s1-s2) | 2 | 2 | 2 | 2 |
+| Fixed network electricity consumption (s2) | 43.2 | 38 | 25 | 14 |
+| Fixed network electricity consumption, T&D (s3) | 4.6 | 3.8 | 2.5 | 1.4 |
+| Fixed network electricity consumption, supply (s3) | 6.9 | 5.7 | 3.8 | 2.1 |
+
+**Table IV.1 – Trajectory including electricity supply chain and grid losses in line with LCA principles (perspective A)**
+
+| | CO2e emissions including electricity supply chain and grid losses (Mt CO2e ) | | | |
+|-------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------|-------------|-------------|-------------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Fixed network supply chain s3 | 4.5 | 3.8 | 3.4 | 3 |
+| Fixed network supply chain, T&D (s3) | 0.5 | 0.4 | 0.4 | 0.3 |
+| Fixed network supply chain, electricity supply (s3) | 0.75 | 0.6 | 0.6 | 0.45 |
+| Data centres | | | | |
+| Data centre manufacturers s1-s2 | 3 | 3.3 | 3.7 | 3.7 |
+| Data centre manufacturers, T&D (s3) | 0.3 | 0.33 | 0.34 | 0.36 |
+| Data centre manufacturers, electricity supply (s3) | 0.45 | 0.48 | 0.51 | 0.54 |
+| Data centre operator overheads (electricity) s2 | 6.4 | 7.2 | 7.2 | 7.2 |
+| Data centre operator overheads (excluding electricity) s1-s2 | 3 | 3 | 3 | 3 |
+| Data centre electricity consumption (s2) | 91.2 | 84 | 60 | 40 |
+| Data centre electricity consumption, T&D (s3) | 9.1 | 7.8 | 5.6 | 3.5 |
+| Data centre electricity consumption, supply (s3) | 13.7 | 11.6 | 8.4 | 5.2 |
+| Data centre supply chain s3 | 12 | 12.5 | 13 | 13 |
+| Data centre supply chain, T&D (s3) | 0.75 | 0.8 | 0.8 | 0.8 |
+| Data centre supply chain, electricity supply (s3) | 1.5 | 1.6 | 1.6 | 1.6 |
+| User devices | | | | |
+| User device manufacturers (non-electricity) | 35 | 35 | 35 | 35 |
+| User device manufacturers electricity (s2/s3) | 70 | 64 | 41 | 23 |
+| User device manufacturers, T&D (s3) | 7 | 6.4 | 4.1 | 2.3 |
+| User device manufacturers, electricity supply (s3) | 10.5 | 9.6 | 6.15 | 10.5 |
+| User device operation (s3) | 169 | 161 | 115 | 72 |
+| User device operation (T&D, s3) | 17 | 16.1 | 11.5 | 7.2 |
+| User device operation, electricity supply (s3) | 25 | 24.2 | 17.3 | 10.8 |
+| User device supply chain non-electricity s3 | 35 | 35 | 35 | 35 |
+| User device supply chain, electricity (s3) | 26 | 22 | 15 | 9 |
+| User device supply chain, T&D (s3) | 2.6 | 2.2 | 1.5 | 0.9 |
+| User device supply chain, electricity supply (s3) | 3.9 | 3.3 | 2.3 | 1.35 |
+| Enterprise networks | | | | |
+| Enterprise network manufacturers electricity (s2/s3) | 0.5 | 0.5 | 0.35 | 0.2 |
+| Enterprise network manufacturers, T&D (s3) | 0.05 | 0.05 | 0.04 | 0.02 |
+| Enterprise network devices manufacturers, electricity supply (s3) | 0.08 | 0.08 | 0.07 | 0.03 |
+| Enterprise network operation (s2/s3) | 12 | 11 | 6 | 4 |
+
+**Table IV.1 – Trajectory including electricity supply chain and grid losses in line with LCA principles (perspective A)**
+
+| | CO2 e emissions including electricity supply chain and grid losses (Mt CO2 e) | | | |
+|----------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------|-------------|--------------|-------------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Enterprise network operation (T&D, s3) | 1.2 | 1.1 | 0.6 | 0.4 |
+| Enterprise network operation (supply, s3) | 1.8 | 1.6 | 0.9 | 0.6 |
+| Total | | | | |
+| Total including grid electricity supply and losses | 740 | 693 | 530 | 388 |
+| | | | | |
+| Number of mobile subscriptions (SIM-cards excluding M2M) | 7.2 billion | 8.2 billion | 8.9 billion | 9.4 billion |
+| Number of fixed subscriptions (lines) | 1.85 billion | 2 billion | 2 billion | 1.9 billion |
+| Number of servers (data centres) | 43 million | 48 million | 52.5 million | 55 million |
+| Number of active PC or employee "users" (enterprises) | 800 million | 850 million | 900 million | 950 million |
+| Number of end-user goods | 13 billion | 15 billion | 18 billion | 20 billion |
+| Number of additional IoT/M2M (possible, included in forecast) | 2 billion | 7.5 billion | 14 billion | 20 billion |
+| Fixed data traffic (ZB) | 1 | 3 | 7 | 12–27 |
+| Mobile data-traffic (ZB) | 0.06 | 0.6 | 2 | 6–10 |
+| This table is colour-coded according to clause 5. | | | | |
+
+**Table IV.2 – Trajectory excluding electricity supply chain and grid losses in line with the SBT initiative accounting principles (perspective B)**
+
+| ICT sector trajectory for the SBT initiative | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) | | | |
+|-------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|------------|------------|------------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Mobile networks | | | | |
+| Mobile network manufacturers (s1-s2) | 3 | 3 | 2 | 1 |
+| Mobile network operator overheads – electricity (s2) | 6.4 | 6.4 | 4.8 | 3.2 |
+| Mobile network operator overheads – excluding electricity (s1-s2) | 4 | 4 | 4 | 4 |
+| Mobile network own electricity generation (s1-s2) | 25 | 23 | 21 | 18 |
+| Mobile network electricity consumption (s2) | 48 | 46 | 35 | 21 |
+| Mobile networks supply chain s3 | 12 | 12 | 12 | 12 |
+| Fixed networks | | | | |
+| Fixed network manufacturers (s1-s2) | 1 | 1 | 0.7 | 0.3 |
+| Fixed network operator overheads – electricity (s2) | 3.2 | 3.2 | 2.4 | 1.6 |
+| Fixed network operator overheads – excluding electricity (s1-s2) | 2 | 2 | 2 | 2 |
+| Fixed network electricity consumption (s2) | 43 | 38 | 25 | 14 |
+| Fixed networks supply chain s3 | 6 | 5 | 4.5 | 4 |
+| Data centres | | | | |
+| Data centre manufacturers s1-s2 | 3 | 3.3 | 2.3 | 1.2 |
+| Data centre operator overheads (electricity) s2 | 6.4 | 7.2 | 5.6 | 3.2 |
+| Data centre operator overheads (excluding electricity) s1-s2 | 3 | 3 | 3 | 3 |
+| Data centre electricity consumption (s2) | 91.2 | 84 | 60 | 40 |
+| Data centre supply chain s3 | 12 | 12.5 | 13 | 13 |
+| User devices | | | | |
+| User device manufacturers (non-electricity) | 35 | 35 | 35 | 35 |
+| User devices manufacturers electricity (s2/s3) | 70 | 64 | 41 | 23 |
+| User devices operation (s3) | 169 | 161 | 115 | 72 |
+| User devices supply chain non-electricity s3 | 35 | 35 | 35 | 35 |
+| User devices supply chain, electricity (s3) | 26 | 22 | 15 | 9 |
+| Enterprise networks | | | | |
+| Enterprise networks manufacturers electricity (s2/s3) | 0.5 | 0.5 | 0.35 | 0.2 |
+| Enterprise networks operation (s2/s3) | 12 | 11 | 6 | 4 |
+| Total | | | | |
+| Total excluding grid electricity supply and losses | 617 | 582 | 445 | 320 |
+
+**Table IV.2 – Trajectory excluding electricity supply chain and grid losses in line with the SBT initiative accounting principles (perspective B)**
+
+| ICT sector trajectory for the SBT initiative | CO 2 e emissions excluding electricity supply chain and grid losses (Mt CO 2 e) | | | |
+|---------------------------------------------------------------|-------------------------------------------------------------------------------------------------------|-------------|--------------|-------------|
+| | 2015 | 2020 | 2025 | 2030 |
+| Number of mobile subscriptions (SIM-cards excluding M2M) | 7.2 billion | 8.2 billion | 8.9 billion | 9.4 billion |
+| Number of fixed subscriptions (lines) | 1.85 billion | 2 billion | 2 billion | 1.9 billion |
+| Number of servers (data centres) | 43 million | 48 million | 52.5 million | 55 million |
+| Number of active PC or employee "users" (enterprises) | 800 million | 850 million | 900 million | 950 million |
+| Number of end-user goods | 13 billion | 15 billion | 18 billion | 20 billion |
+| Number of additional IoT/M2M (possible, included in forecast) | 2 billion | 7.5 billion | 14 billion | 20 billion |
+| Fixed data traffic (ZB) | 1 | 3 | 7 | 12-27 |
+| Mobile data-traffic (ZB) | 0.06 | 0.6 | 2 | 6-10 |
+| This table is colour-coded according to clause 5. | | | | |
+
+### **IV.3 Step 3: ICT and grid development plus additional purchase of renewables**
+
+As stated in clause 9.1, the 1.5°C scenario for the grid electricity is very challenging and the actual trajectory may be worse. However, given the ICT sector's opportunity to purchase and invest in renewables beyond the average grid development, e.g., through PPAs, there are different ways to achieve a decarbonization in line with the scenario shown in clause V.2 in order to stay within the normative limits for the trajectory as outlined in clause 9.
+
+Sector opportunities that impact the overall usage of renewables include the following.
+
+- Diesel usage for off grid mobile network sites is expected to reduce, but is not likely to be fully phased out during the period to 2030.
+- A switch to renewable ES for end-user goods could be impacted by integrating renewable ES into subscriptions (new business model).
+- Large potential for renewables for establishment of new data centres as they are relatively few ([b-Cisco] forecasts that less than 1 000 can handle over 90% of all data traffic) and could be located quite freely compared to access sites that represent a much higher number of physical sites (counted in 10s of millions), which also need to be located where they are used for technical reasons.
+ - Several major data centre operators are already using 100% renewable supply.
+ - Fewer physical sites and less dependency on proximity to users means that data centres may be more easily established in regions with grids with a high share of renewables. Edge computing is a special case, but is mainly related to special use cases that need low latency (e.g., gaming and self-driving cars), which are expected to have a more limited impact on the footprint during the coming decade.
+ - Fewer physical sites means that local provisioning of renewable electricity becomes easier.
+
+## Appendix V
+
+### The importance of renewables
+
+(This appendix does not form an integral part of this Recommendation.)
+
+#### Background
+
+This appendix outlines the importance of the availability of renewables and of continued energy performance improvements for the ICT sector to decarbonize.
+
+The decarbonization of the ICT sector – as of the world – is to a high extent dependent on the availability of renewables, which has been a precondition for the main scenarios. Renewables could be made available through decarbonization of the electricity grid, additional purchase of renewables and through the sector's investment in its own electricity sources.
+
+This appendix shows how ICT footprints could evolve if the power sector (as in the past) does not live up to what is needed under [b-UNFCCC PA] and the [b-IPCC 1.5], and if the ICT sector fails to mitigate that through purchase of renewables and its own ES.
+
+The starting point for this analysis is [b-Andrae 2015], which have been combined with the scenario for ICT sector development.
+
+The risk scenario provided in this appendix assumes that the decarbonization of the grid does not take off, that the sector cannot mitigate this through PPAs and its own investments, and that the sector itself fails to increase its energy performance along historical lines while it continues to grow.
+
+This appendix does not evaluate the likelihood of this scenario from the policy, regulations and economic standpoints, but aims to show the importance of active decarbonization strategies.
+
+### V.1 The global energy and electricity situation – some confirmation of IEA and other statistics
+
+There is reason to believe that the need for global primary energy supply (PES) will increase in the next decade. For instance, [b-US EIA] estimates that PES will increase by 28% between 2015 and 2040 and that coal, oil, gas will make up more than 75% of the supply in 2040.
+
+Some estimates of global PES, ES expressed as primary energy and related CO2 emissions in 2018 and 2030 follow.
+
+Tables V.1-V.2 summarize estimates made using the literature.
+
+**Table V.1 – Summary of electricity trends between 2018 and 2030**
+
+| | Electricity supply 2018 (TWh) [b-BP] | Annual growth rate 2018 to 2030 (%) [b-Andrae 2020] | Electricity supply 2030 (TWh) [b-Andrae 2020] |
+|---------------------------------------------------|--------------------------------------------|-----------------------------------------------------------|-----------------------------------------------------|
+| Coal | 10 101 | 2.2% | 13 098 |
+| Oil | 803 | -1.5% | 671 |
+| Gas | 6 183 | 2.5% | 8 290 |
+| Nuclear | 2 701 | 2.0% | 3 417 |
+| Hydro | 4 193 | 2.2% | 5 466 |
+| Wind, solar, biomass, other renewables | 2 634 | 4.5% | 4 454 |
+| TOTALS | 26 615 | | 35 395 |
+
+In 2019 BP published new data as 13865 million tonnes oil equivalents PES for 2018 ([b-BP]), increasing 2.9% (!) from 2017. Coal increase from 3718 to 3772, Gas from 3142 to 3309 and Oil from 4607 to 4662 Mtoe.
+
+Table V.2 shows that the demand for coal, oil and gas is expected to continue which leads to increasing CO2 emissions. Oil is not used so much as an electricity carrier but its use as fuel oil will still lead to more CO2 emissions.
+
+Between 2018 and 2030 the global CO2 emissions related to energy conversion will increase ≈16% from ≈34.9 Gt to ≈40.4 Gt.
+
+**Table V.2 – Summary of the energy, electricity and CO2 situation in 2018 and prediction 2030**
+
+| | Primary energy supply 2018 (megatonne oil equivalents, Mtoe) | Electricity supply 2018 (Mtoe) | CO 2 other 2018 (Mt) | CO 2 ES 2018 | PES 2030 (Mtoe) | ES 2030 (Mtoe) | CO 2 other 2030 (Mt) | CO 2 ES 2030 (Mt) |
+|-------------------------|--------------------------------------------------------------|--------------------------------|---------------------------------|-------------------------|-----------------|----------------|---------------------------------|------------------------------|
+| Coal | 3 772 | 2 345 | 5 077 | 9 898 | 3 723 | 3 041 | 1 944 | 12 836 |
+| Oil | 4 662 | 186 | 11 778 | 716 | 6 204 | 156 | 16 027 | 598 |
+| Gas | 3 309 | 1 435 | 3 289 | 4 025 | 4 048 | 1 924 | 3 549 | 5 396 |
+| Nuclear | 611 | 720 | | 27 | 739 | 793 | | 34 |
+| Hydro | 949 | 949 | | 42 | 1 264 | 1 269 | | 55 |
+| Other renewables | 561 | 561 | | 26 | 1 395 | 1 034 | | 45 |
+| TOTALS | 13 865 | 6 197 | 20 144 | 14 735 | 17 372 | 1 924 | 21 520 | 18 964 |
+
+Figures V.1 to V.5 show some graphical summaries of Tables V.1 and V.2. The motivation for repeating the global energy situation is to put ICT Sector into perspective being 1-2%1 of global PES and 3-4%2 of global electricity supply. 2015 and 2018 are assumed to be quite similar in this sense.
+
+1 1000 TWh×2.7 TWh/TWh)/(14299×11.63) = 0.016
+
+2 1000 TWh/26673 TWh = 0.037
+
+
+
+**Trends in the global energy and electricity systems from 2018 to 2030.
+Primary energy supply (PES) and electricity supply (ES) in MToe and CO2 in Mtonnes.**
+
+| Energy Source | PES 2018 | ES 2018 | CO 2 other 2018 | CO 2 EL 2018 | PES 2030 | ES 2030 | CO 2 other 2030 | CO 2 EL 2030 |
+|------------------|----------|---------|----------------------------|-------------------------|----------|---------|----------------------------|-------------------------|
+| Coal | 3800 | 2300 | 5077 | 9898 | 4800 | 3800 | 12836 | 1944 |
+| Oil | 4800 | 11778 | 716 | 16027 | 6200 | 598 | | |
+| Gas | 3500 | 1500 | 3289 | 4025 | 3800 | 3549 | 5396 | |
+| Nuclear | 800 | 27 | | | 800 | 34 | | |
+| Hydro | 1000 | 42 | | | 1000 | 55 | | |
+| Other renewables | 800 | 26 | | | 1000 | 45 | | |
+
+L.1470(20)\_FV.1
+
+Bar chart showing global energy and electricity supply trends from 2018 to 2030 for Coal, Oil, Gas, Nuclear, Hydro, and Other renewables. The chart includes data for Primary Energy Supply (PES), Electricity Supply (ES), and CO2 emissions for 2018 and 2030.
+
+**Figure V.1 – Summary of global trends 2018 to 2030 for energy, electricity supply and related CO2 emissions**
+
+
+
+**Trends in the global energy and electricity systems from 2018 to 2030.
+Primary energy supply (PES) and electricity supply (ES) in MToe**
+
+| Energy Source | PES 2018 | PES 2030 | ES 2018 | ES 2030 |
+|------------------|----------|----------|---------|---------|
+| Coal | 3800 | 3800 | 2300 | 3000 |
+| Oil | 4800 | 6200 | 11778 | 598 |
+| Gas | 3500 | 4000 | 1500 | 2000 |
+| Nuclear | 800 | 800 | 27 | 34 |
+| Hydro | 1000 | 1000 | 42 | 55 |
+| Other renewables | 800 | 1000 | 26 | 45 |
+
+L.1470(20)\_FV.2
+
+Bar chart showing global energy and electricity supply trends from 2018 to 2030 for Coal, Oil, Gas, Nuclear, Hydro, and Other renewables. The chart includes data for Primary Energy Supply (PES) and Electricity Supply (ES) for 2018 and 2030.
+
+**Figure V.2 – Summary of global trends from 2018 to 2030 for energy and electricity supply**
+
+Figure V.3 shows that in the risk scenario CO2 emissions from oil use in non-electricity sectors increase, as well as coal-related CO2 emissions.
+
+
+
+| Category | Year | Coal (million tonnes) | Oil (million tonnes) | Gas (million tonnes) |
+|----------------------------|------|-----------------------|----------------------|----------------------|
+| CO 2 from other | 2018 | ~5,000 | ~12,000 | ~3,000 |
+| | 2030 | ~2,000 | ~16,000 | ~3,000 |
+| CO 2 from EL | 2018 | ~10,000 | ~1,000 | ~4,000 |
+| | 2030 | ~13,000 | ~1,000 | ~5,000 |
+
+Bar chart titled 'Global CO2 emissions from electricity production compared to other sources 2018 and 2030, million tonnes'. The chart compares CO2 emissions from Coal, Oil, and Gas for two categories: 'CO2 from other' and 'CO2 from EL' (Electricity Production) for the years 2018 and 2030. The y-axis ranges from 0 to 20,000 million tonnes. In 2018, 'CO2 from other' shows Oil at ~12,000, Coal at ~5,000, and Gas at ~3,000. 'CO2 from EL' shows Coal at ~10,000, Gas at ~4,000, and Oil at ~1,000. In 2030, 'CO2 from other' shows Oil at ~16,000, Coal at ~2,000, and Gas at ~3,000. 'CO2 from EL' shows Coal at ~13,000, Gas at ~5,000, and Oil at ~1,000.
+
+L.1470(20)\_FV.3
+
+Figure V.3 – Summary of global trends from 2018 to 2030 for energy and electricity-related CO2 emissions
+
+
+
+| Electricity Carrier | Percentage |
+|---------------------|------------|
+| Coal | 38% |
+| Gas | 23% |
+| Hydro | 15% |
+| Nuclear | 12% |
+| Other renewables | 9% |
+| Oil | 3% |
+
+Pie chart titled 'ES 2018' showing the global partition of electricity carriers in 2018. The chart shows the following distribution: Coal (38%), Gas (23%), Hydro (15%), Nuclear (12%), Other renewables (9%), and Oil (3%). A legend on the right lists the carriers and their corresponding colors: Coal (blue), Oil (orange), Gas (grey), Nuclear (yellow), Hydro (dark blue), and Other renewables (green).
+
+L.1470(20)\_FV.4
+
+Figure V.4 – Summary of global partition of electricity carriers in 2018
+
+
+
+| Electricity Carrier | Percentage |
+|---------------------|------------|
+| Coal | 37% |
+| Gas | 23% |
+| Hydro | 15% |
+| Other renewables | 13% |
+| Nuclear | 10% |
+| Oil | 2% |
+
+Pie chart titled 'ES 2030' showing the global partition of electricity carriers in 2030. The chart is divided into six segments: Coal (37%), Gas (23%), Hydro (15%), Other renewables (13%), Nuclear (10%), and Oil (2%). A legend on the right side lists the carriers and their corresponding colors: Coal (blue), Oil (orange), Gas (grey), Nuclear (yellow), Hydro (dark blue), and Other renewables (green).
+
+**Figure V.5 – Summary of global partition of electricity carriers in 2030**
+
+### V.2 ICT footprints
+
+Based on such development of the grid, the risk scenario next considers a development where the energy performance improvements of the ICT sector decline compared to historical development.
+
+This scenario does not evaluate how economic, policy and regulation developments would restrict such a development, but aims to show the importance for the sector to continue working on its energy performance.
+
+In this scenario, the total terawatt hour value for computing – of which the ICT sector is presumably a large share – in 2030 is estimated starting from:
+
+- [operations/s/operations/J], see [b-Andrae 2019a];
+- [J/operation×operations/s], see [b-Andrae 2019a].
+- Sweden terawatt hour for ICT per capita in 2030, see [b-Malmodin, Lundén 2016] × world population in 2030.
+
+NOTE 1 – This scenario uses another baseline to the rest of this Recommendation, which also impacts resulting future estimates.
+
+NOTE2 – The scenario in this appendix considers aspects of [b-Andrae 2019a].
+
+**Table V.3 – Baseline CO2 emissions and use stage power use for the ICT sector in 2015**
+
+| | Electricity consumption | Use stage carbon footprint | Embodied carbon footprint | |
+|-----------------------------------------|-------------------------|----------------------------|---------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------|
+| User devices | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Mobile devices, smartphones and tablets | 29 a | 17 | 51 | |
+| Other devices | | | | |
+| CPE + fixed phones | 82 b | 50 | | CPE = modems, gateways, routers etc. |
+| PCs, PC displays, PC peripherals | 307 c | 187 | 72 | |
+| Total: | 418 | 254 | 123 | |
+| ICT networks | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Mobile networks | 152 d | 93 | | |
+| Fixed networks | 179 [b-Andrae 2019b] | 109 | | 179 TWh electricity in 2015, basis for value: 2012 196 TWh [b-Lambert]: 350 TWh – CPE (51.2) = 298 TWh 298 TWh – Office (42 TWh) = 256 TWh |
+
+**Table V.3 – Baseline CO2 emissions and use stage power use for the ICT sector in 2015**
+
+| | Electricity consumption | Use stage carbon footprint | Embodied carbon footprint | |
+|---------------------------------------------|-------------------------|----------------------------|-------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | | | Fixed was 60% of the 256 TWh = 154 TWh. Fixed + Office = 154 + 42 = 196 TWh 2013: (568 EB/470 EB)*0.8*196 TWh = 190 2014: (689 EB/568 EB)*0.8*190 TWh = 184 2015: (839 EB/689 EB)*0.8*184 TWh = 179 TWh. 179 TWh*0.61 MtCO 2 /TWh = 109 Mt CO 2 |
+| Total | 331 | 202 | | |
+| Data centres and Enterprise networks | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Data centres/rooms | 220 [b-Andrae 2019b] | 134 | | |
+| Total | 220 | 134 | | |
+| ICT sector total | 969 | 590 | 123 | |
+| | | | 590 + 123 = 713 = 0.713 Gt | |
+
+a Expected case: smartphones, tablets, ordinary phones, phablets in [b-Challenges].
+b Expected case, fixed access Wi-Fi in [b-Challenges].
+c Expected case, desktops, monitors, laptops in [b-Challenges].
+d Expected case, wireless in [b-Challenges].
+
+Other devices and embedded footprint of ICT networks and data centres – excluded from the estimation – will add to the estimate in Table 3.
+
+Table V.4 shows an estimate for the ICT sector in 2030.
+
+**Table V.4 – CO2 emissions and use stage power use for the ICT sector in 2030**
+
+| | Electricity consumption | Use stage carbon footprint | Embodied carbon footprint | |
+|-----------------------------------------|---------------------------------------|----------------------------|---------------------------|--------------------------------------|
+| | | | | |
+| User devices | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Mobile devices, smartphones and tablets | 52 | 20 | 45 | |
+| Other devices | 9 | 3 | 10 | |
+| CPE + Fixed phones | 107 (Figure 6 of [b-Andrae 2019c]) | 41 | | CPE = modems, gateways, routers etc. |
+| PCs, PC displays, PC peripherals | 141 | 54 | 16 | |
+| Total: | 309 (–26%) | 118 (–53%) | 71 (–42%) | |
+| ICT networks | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Mobile networks | 277 [b-Andrae 2015] | 105 | | |
+| Fixed networks | 195 (Figure 6 of [b-Andrae 2019c]) | 74 | | |
+| Total: | 472 (+42%) | 179 (–12%) | | |
+
+**Table V.4 – CO2 emissions and use stage power use for the ICT sector in 2030**
+
+| | Electricity consumption | Use stage carbon footprint | Embodied carbon footprint | |
+|---------------------------------------------|---------------------------------------|-----------------------------------|----------------------------------|--|
+| Data centres and Enterprise networks | TWh | Mt CO 2 e | Mt CO 2 e | |
+| Data centres/rooms | 411 (Figure 6 of [b-Andrae 2019c]) | 156 | | |
+| Total: | 411 (+86%) | 156 (+16%) | | |
+| ICT sector total | 1192 (+23%) | 453 (–23%) | 71(–42%) | |
+
+## Bibliography
+
+- [b-ITU-T L.1000] Recommendation ITU-T L.1000 (2019), *Universal power adapter and charger solution for mobile terminals and other hand-held ICT devices.*
+- [b-ITU-T L.1001] Recommendation ITU-T L.1001 (2012), *External universal power adapter solutions for stationary information and communication technology devices.*
+- [b-ITU-T L.1006] Recommendation ITU-T L.1006 (2016), *Test suites for assessment of the external universal power adapter solutions for stationary information and communication technology devices.*
+- [b-ITU-T L.1007] Recommendation ITU-T L.1007 (2016), *Test suites for assessment of the external universal power adapter solutions for portable information and communication technology devices.*
+- [b-ITU-T L.1010] Recommendation ITU-T L.1010 (2014), *Green battery solutions for mobile phones and other hand-held information and communication technology devices.*
+- [b-ITU-T L.1015] Recommendation ITU-T L.1015 (2019), *Criteria for evaluation of the environmental impact of mobile phones.*
+- [b-ITU-T L.1020] Recommendation ITU-T L.1020 (2018), *Circular economy: Guide for operators and suppliers on approaches to migrate towards circular ICT goods and networks.*
+- [b-ITU-T L.1021] Recommendation ITU-T L.1021 (2018), *Extended producer responsibility – Guidelines for sustainable e-waste management.*
+- [b-ITU-T L.1022] Recommendation ITU-T L.1022 (2019), *Circular economy: Definitions and concepts for material efficiency for information and communication technology.*
+- [b-ITU-T L.1200] Recommendation ITU-T L.1200 (2012), *Direct current power feeding interface up to 400 V at the input to telecommunication and ICT equipment.*
+- [b-ITU-T L.1201] Recommendation ITU-T L.1201 (2014), *Architecture of power feeding systems of up to 400 VDC.*
+- [b-ITU-T L.1202] Recommendation ITU-T L.1202 (2015), *Methodologies for evaluating the performance of an up to 400 VDC power feeding system and its environmental impact.*
+- [b-ITU-T L.1203] Recommendation ITU-T L.1203 (2016), *Colour and marking identification of up to 400 VDC power distribution for information and communication technology systems.*
+- [b-ITU-T L.1204] Recommendation ITU-T L.1204 (2016), *Extended architecture of power feeding systems of up to 400 VDC.*
+- [b-ITU-T L.1205] Recommendation ITU-T L.1205 (2016), *Interfacing of renewable energy or distributed power sources to up to 400 VDC power feeding systems.*
+
+| | |
+|------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [b-ITU-T L.1206] | Recommendation ITU-T L.1206 (2017), Impact on ICT equipment architecture of multiple AC, –48VDC or up to 400 VDC power inputs. |
+| [b-ITU-T L.1207] | Recommendation ITU-T L.1207 (2018), Progressive migration of a telecommunication/information and communication technology site to 400 VDC sources and distribution. |
+| [b-ITU-T L.1220] | Recommendation ITU-T L.1220 (2017), Innovative energy storage technology for stationary use – Part 1: Overview of energy storage. |
+| [b-ITU-T L.1221] | Recommendation ITU-T L.1221 (2018), Innovative energy storage technology for stationary use – Part 2: Battery. |
+| [b-ITU-T L.1222] | Recommendation ITU-T L.1222 (2018), Innovative energy storage technology for stationary use – Part 3: Supercapacitor technology. |
+| [b-ITU-T L.1300] | Recommendation ITU-T L.1300 (2014), Best practices for green data centres. |
+| [b-ITU-T L.1301] | Recommendation ITU-T L.1301 (2015), Minimum data set and communication interface requirements for data centre energy management. |
+| [b-ITU-T L.1302] | Recommendation ITU-T L.1302 (2015), Assessment of energy efficiency on infrastructure in data centres and telecom centres. |
+| [b-ITU-T L.1303] | Recommendation ITU-T L.1303 (2018), Functional requirements and framework of green data centre energy-saving management system. |
+| [b-ITU-T L.1310] | Recommendation ITU-T L.1310 (2017), Energy efficiency metrics and measurement methods for telecommunication equipment. |
+| [b-ITU-T L.1315] | Recommendation ITU-T L.1315 (2017), Standardization terms and trends in energy efficiency. |
+| [b-ITU-T L.1320] | Recommendation ITU-T L.1320 (2014), Energy efficiency metrics and measurement for power and cooling equipment for telecommunications and data centres. |
+| [b-ITU-T L.1321] | Recommendation ITU-T L.1321 (2015), Reference operational model and interface for improving energy efficiency of ICT network hosts. |
+| [b-ITU-T L.1325] | Recommendation ITU-T L.1325 (2016), Green ICT solutions for telecom network facilities. |
+| [b-ITU-T L.1330] | Recommendation ITU-T L.1330 (2015), Energy efficiency measurement and metrics for telecommunication networks. |
+| [b-ITU-T L.1331] | Recommendation ITU-T L.1331 (2017), Assessment of mobile network energy efficiency. |
+| [b-ITU-T L.1332] | Recommendation ITU-T L.1332 (2018), Total network infrastructure energy efficiency metrics. |
+| [b-ITU-T L.1340] | Recommendation ITU-T L.1340 (2014), Informative values on the energy efficiency of telecommunication equipment. |
+
+[b-ITU-T L.1350] Recommendation ITU-T L.1350 (2016), *Energy efficiency metrics of a base station site*.
+
+[b-ITU-T L.1351] Recommendation ITU-T L.1351 (2018), *Energy efficiency measurement methodology for base station sites*.
+
+[b-ITU-T L.1360] Recommendation ITU-T L.1360 (2016), *Energy control for the software-defined networking architecture*.
+
+[b-ITU-T L.1361] Recommendation ITU-T L.1361 (2018), *Measurement method for energy efficiency of network functions virtualization*.
+
+[b-ITU-T L.1362] Recommendation ITU-T L.1362 (2019), *Interface for power management in network function virtualization environments – Green abstraction Layer version 2*.
+
+[b-ITU-T L.1370] Recommendation ITU-T L.1370 (2018), *Sustainable and intelligent building services*.
+
+[b-ITU-T L.1400] Recommendation ITU-T L.1400 (2011), *Overview and general principles of methodologies for assessing the environmental impact of information and communication technologies*.
+
+[b-ITU-T L.1410] Recommendation ITU-T L.1410 (2014), *Methodology for environmental life cycle assessments of information and communication technology goods, networks and services*.
+
+[b-ITU-T Y.1910] Recommendation ITU-T Y.1910 (2008), *IPTV functional architecture*.
+
+[b-Andrae 2015] Andrae, A.S.G., Edler, T. (2015). On global electricity usage of communication technology: Trends to 2030. *Challenges*, 6, pp. 117-157. Available [viewed 2020-03-24] at: .
+
+[b-Andrae 2019a] Andrae, A.S.G. (2019). Prediction studies of electricity use of global computing in 2030. *Int. J. Sci. Eng. Invest.* 8(86), pp. 27-33. Available [viewed 2020-03-24] at:
+
+[b-Andrae 2019b] Andrae, A.S.G. (2019). Comparison of several simplistic high-level approaches for estimating the global energy and electricity use of ICT networks and data centers. *Int. J. Green Technol.* 5, pp. 50-63. Available [viewed 2020-03-28] at: . DOI:
+
+[b-Andrae 2019c] Andrae, A.S.G. (2019c). *Projecting the chiaroscuro of the electricity use of communication and computing from 2018 to 2030* [Preprint]. DOI: 10.13140/RG.2.2.25103.02724
+
+[b-Andrae 2020] Andrae, A.S.G. (2020). *Hypotheses for primary energy use, electricity use and CO2 emissions of global computing and its shares of the total between 2020 and 2030*, WSEAS Transactions on Power Systems, ISSN / E-ISSN: 1790-5060 / 2224-350X, Volume 15, 2020, Art. #6, pp. 50-59. Available [viewed 2020-05-06] at: DOI:
+
+[b-BP] BP (1996-2020). *Statistical review of world energy*. London: BP. Available [viewed 2020-03-24] at:
+
+
+
+- [b-Business Insider] Business Insider. *Business Insider Intelligence*. Available [viewed 2020-03-30] at:
+- [b-Challenges] Available [viewed 2020-03-24] at:
+- [b-Cisco] Barnett, Jr., T., Jain, S., Andra, U., Khurana, T. (2018). *Cisco visual networking index (VNI) – Complete forecast update, 2017–2022 – Americas/EMEAR Cisco Knowledge Network (CKN) presentation*. San Jose, CA: Cisco. 125 pp. Available [viewed 2020-04-20] at: [https://www.cisco.com/c/dam/m/en\\_us/network-intelligence/service-provider/digital-transformation/knowledge-network-webinars/pdfs/1211\\_BUSINESS\\_SERVICES\\_CKN\\_PDF.pdf](https://www.cisco.com/c/dam/m/en_us/network-intelligence/service-provider/digital-transformation/knowledge-network-webinars/pdfs/1211_BUSINESS_SERVICES_CKN_PDF.pdf)
+- [b-Comms Update] Comms Update (2019). *China Mobile closing down 3G system, complete switch-off expected by 2020*. Washington, DC: TeleGeography. Available [viewed 2020-03-24] at:
+- [b-DTVR] Digital TV Research (2016). *Digital TV world data book 2016*. Harrow: Digital TV Research. 80 pp. + Excel file. Available [viewed 2020-03-24] from: [https://www.digitaltvresearch.com/ugc/Digital%20TV%20World%20Databook%202016%20TOC\\_toc\\_142.pdf](https://www.digitaltvresearch.com/ugc/Digital%20TV%20World%20Databook%202016%20TOC_toc_142.pdf).
+- [b-Enerdata] Enerdata (2017). *Global statistical yearbook 2017. Electricity domestic consumption*. Grenoble: Enerdata.
+- [b-Ericsson 1994-2020] Ericsson (1994-2020). *Ericsson mobility visualizer*. Stockholm: Telefonaktiebolaget LM Ericsson. Available [viewed 2020-03-29] at:
+- [b-Ericsson MR2019] Ericsson (2019). *The Ericsson mobility report*, annual. Stockholm: Telefonaktiebolaget LM Ericsson. Available [viewed 2020-04-21] at:
+- [b-Facebook] Facebook (2016). *Facebook sustainability. Our footprint*. Menlo Park, CA: Facebook.[b-Fuchs] Fuchs, H., Shehabi, A., Ganeshalingam, M., Desroches, L.-B., Lim, B., Roth, K., Tsao, A. (2017). *Characteristics and energy use of volume servers in the United States*. Berkeley, CA: Lawrence Berkeley National Laboratory. 52 pp. Available [viewed 2020-03-28] at:
+- [b-Future Source] Future Source (2020). *Market research, forecasts and strategic insights in technology, media and entertainment*. St Albans: Futuresource Consulting. Available [viewed 2020-03-29] at:
+- [b-Gartner] Gartner (Internet). Worldwide device shipments [quarterly press releases]. Stamford, CT: Gartner. Example available [viewed 2020-03-28] at:
+- [b-GHG P] Greenhouse Gas Protocol (2004). *The greenhouse gas protocol: A corporate accounting and reporting standard*, revised edition. Geneva: World Business Council for Sustainable Development;
+
+- Washington, DC: World Resources Institute. 116 pp. Available [viewed 2020-03-27] at: [http://pdf.wri.org/ghg\\_protocol\\_2004.pdf](http://pdf.wri.org/ghg_protocol_2004.pdf)
+- [b-GHG P Sc2] Greenhouse Gas Protocol (2015). *GHG protocol: Scope 2 guidance*, amendment to the *GHG protocol: Corporate standard*. Washington, DC: World Resources Institute. 120 pp. Available [viewed 2020-03-27] at: [https://ghgprotocol.org/sites/default/files/standards/Scope%202%20Guidance\\_Final\\_Sept26.pdf](https://ghgprotocol.org/sites/default/files/standards/Scope%202%20Guidance_Final_Sept26.pdf)
+- [b-GHG P Sc3] GreenHouse Gas Protocol (2011). *Corporate value chain (scope 3) accounting and reporting standard*, supplement to the *GHG protocol: Corporate accounting and reporting standard*, Geneva: World Business Council for Sustainable Development; Washington, DC: World Resources Institute. 152 pp. September 2011. Available [viewed 2020-04-01] at:
+- [b-Google 2016a] Google (2016). *Environmental report: 2016*. 72 pp. Available [viewed 2020-03-29] from:
+- [b-Google 2016b] Google (2016). *Alphabet's 2016 CDP climate change response*. 30 pp. Available [viewed 2020-03-29] from:
+- [b-GSMA] GSMA (2020). *The mobile economy*. London: GSM Association. Available [viewed 2020-03-29] at:
+- [b-Guidehouse Insights] Guidehouse Insights (2020). *Empower your transformation*. Available [viewed 2020-03-30] at:
+- [b-IDC] IDC (2020). *Maximize your competitive advantage with IDC's leading research*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-30] at:
+- [b-IDC 3] IDC (2020). *Worldwide quarterly hardcopy peripherals tracker*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-30] at: [https://www.idc.com/tracker/showproductinfo.jsp?prod\\_id=3](https://www.idc.com/tracker/showproductinfo.jsp?prod_id=3)
+- [b-IDC 7] IDC (2020). *Worldwide quarterly server tracker*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-28] at: [https://www.idc.com/tracker/showproductinfo.jsp?prod\\_id=7](https://www.idc.com/tracker/showproductinfo.jsp?prod_id=7)
+- [b-IDC 37] IDC (2020). *Worldwide quarterly mobile phone tracker*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-30] at: [https://www.idc.com/tracker/showproductinfo.jsp?prod\\_id=37](https://www.idc.com/tracker/showproductinfo.jsp?prod_id=37)
+- [b-IDC 962] IDC (2020). *Worldwide quarterly wearable device tracker*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-30] at: [https://www.idc.com/tracker/showproductinfo.jsp?prod\\_id=962](https://www.idc.com/tracker/showproductinfo.jsp?prod_id=962)
+- [b-IDC 1541] IDC (2020). *Worldwide quarterly personal computing device tracker*. Framingham, MA: International Data Corporation. Available [viewed 2020-03-30] at: [https://www.idc.com/tracker/showproductinfo.jsp?prod\\_id=1541](https://www.idc.com/tracker/showproductinfo.jsp?prod_id=1541)
+- [b-IEA 2019] IEA (2019). *Global energy and CO2 status report 2019: The latest trends in energy and emissions in 2018*. Paris: International
+
+- Energy Agency. Available [viewed 2020-03-24] at:
+
+- [b-IEA Digitalization] IEA (2017). *Digitalisation and energy: Technology report*. Paris: International Energy Agency. Available [viewed 2020-03-26] at:
+
+- [b-IEA ETP 2017] International Energy Agency (2017). *Energy technology perspectives 2017*. Paris: International Energy Agency. Available [viewed 2020-03-26] at:
+- [b-IEA Fuel] IEA (2019). *CO2 emissions from fuel combustion – Highlights – 2019*. Paris: International Energy Agency. 165 pp. Available [viewed 2020-03-30] at:
+[https://iea.blob.core.windows.net/assets/eb3b2e8d-28e0-47fd-a8ba-160f7ed42bc3/CO2\\_Emissions\\_from\\_Fuel\\_Combustion\\_2019\\_Highlights.pdf](https://iea.blob.core.windows.net/assets/eb3b2e8d-28e0-47fd-a8ba-160f7ed42bc3/CO2_Emissions_from_Fuel_Combustion_2019_Highlights.pdf).
+- [b-IEEE Com Soc] IEEE Communications Society (2020). *Technology blog: AT&T to shut down 3G network in 2022; Verizon at end of 2019*. New York, NY: IEEE. Available [viewed 2020-03-30] at:
+
+- [b-IPCC 1.5] Intergovernmental Panel on Climate Change (2018). *Special report: Global warming of 1.5°C*. Available [viewed 2020-03-25] at:
+- [b-ISIC] Department of Economic and Social Affairs, Statistics Division (2008). International standard industrial classification of all economic activities. *Statistical Papers, Series M, No. 4, Rev. 4*. New York, NY: United Nations. 306 pp. Available [viewed 2020-03-27] at: [https://unstats.un.org/unsd/publication/seriesm/seriesm\\_4rev4e.pdf](https://unstats.un.org/unsd/publication/seriesm/seriesm_4rev4e.pdf)
+- [b-ITU 2005–2019] ITU (2005–2019). *Key ICT indicators for developed and developing countries and the world (totals and penetration rates)*. Available [viewed 2020-04-21] at: [https://www.itu.int/en/ITU-D/Statistics/Documents/statistics/2019/ITU\\_Key\\_2005-2019\\_ICT\\_data\\_with%20LDCs\\_28Oct2019\\_Final.xls](https://www.itu.int/en/ITU-D/Statistics/Documents/statistics/2019/ITU_Key_2005-2019_ICT_data_with%20LDCs_28Oct2019_Final.xls)
+- [b-JPR 2014] JPR (2014). *Millions of Android gaming consoles on the horizon: There's a new game machine in town*. Tiburon, CA: Jon Peddie Research. Available [viewed 2020-03-30] at:
+
+- [b-Koenig] Koenig, S (2016). *Global tech spending update*. Slides from presentation at Consumer Electronics Show, Las Vegas, NV, 2016-01-06/09. 31 pp. Available [viewed 2020-03-30] at:
+
+- [b-Koomey] Koomey, J.G. (2011). *Growth in data center electricity use 2005 to 2010*. Oakland, CA: Analytics Press. 24 pp. Available [viewed 2020-03-30] at:
+[https://www.missioncriticalmagazine.com/ext/resources/MC/Home/Files/PDFs/Koomey\\_Data\\_Center.pdf](https://www.missioncriticalmagazine.com/ext/resources/MC/Home/Files/PDFs/Koomey_Data_Center.pdf)
+- [b-Lambert] Lambert, S., Van Heddeghem, W., Vereecken, W., Lannoo, B., Colle, D., Pickavet, M. (2012). Worldwide electricity consumption of communication networks. *Opt. Express*, **20**, pp. B513-B524. Available [viewed 2020-03-31] at:
+
+[https://www.osapublishing.org/DirectPDFAccess/E40F17D1-FE94-C142-97A31E89D3E1D09A\\_246736/oe-20-26-B513.pdf?da=1&id=246736&seq=0&mobile=no](https://www.osapublishing.org/DirectPDFAccess/E40F17D1-FE94-C142-97A31E89D3E1D09A_246736/oe-20-26-B513.pdf?da=1&id=246736&seq=0&mobile=no)
+
+- [b-Malmodin 2010] Malmodin, J., Moberg, Å., Lundén, D., Finnveden, G., Lövehagen, N. (2010). Greenhouse gas emissions and operational electricity use in the ICT and entertainment and media sectors, *Journal of Industrial Ecology*, **14**, pp 770-790. October 2010. DOI: [10.1111/j.1530-9290.2010.00278.x](https://doi.org/10.1111/j.1530-9290.2010.00278.x). Available [viewed 2020-03-24] at:
+- [b-Malmodin 2013] Malmodin, J., Bergmark, P., Lundén, D. (2013). The future carbon footprint of the ICT and E&M sectors. In: Hilty, L.M, Aebischer, B., Andersson, G., Lohmann, W. (editors). *Proceedings of the First International Conference on Information and Communication Technologies for Sustainability (ICT4S)*, Zürich, Switzerland, 2013-02-14/16, pp. 12-20. Available [viewed 2020-03-30] at: [http://2013.ict4s.org/wp-content/uploads/paper/Malmodin\\_et\\_al\\_Future\\_Carbon\\_Footprint\\_of\\_ICT\\_and\\_E&M\\_Sectors.pdf](http://2013.ict4s.org/wp-content/uploads/paper/Malmodin_et_al_Future_Carbon_Footprint_of_ICT_and_E&M_Sectors.pdf)
+- [b-Malmodin 2014a] Malmodin, J., Lundén, D., Moberg, Å, Andersson G, Nilsson, M. (2014). Life cycle assessment of ICT: Carbon footprint and operational electricity use from the operator, national and subscriber perspective in Sweden. *J. Indust. Ecol*, **18**, pp. 829-845. DOI:
+- [b-Malmodin 2014b] Malmodin, J., Lundén, D., Moberg, Å, Andersson G, Nilsson, M. (2014). Life cycle assessment of ICT: Carbon footprint and operational electricity use from the operator, national, and subscriber perspective in Sweden – Supplementary material. *J. Indust. Ecol*.
+- [b-Malmodin, Coroama 2016] Malmodin, J., Coroama, V. (2016). Assessing ICT's enabling effect through case study extrapolation – The example of smart metering. *Electronics Goes Green 2016+ (EGG)*, Berlin, pp. 1-9. Available [viewed 2020-03-30] at:
+- [b-Malmodin, Lundén 2016] Malmodin, J., Lundén, D. (2016). The energy and carbon footprint of the ICT and E&M sector in Sweden 1990-2015 and beyond. In: *Proceedings of the 4th International Conference on ICT for Sustainability (ICT4S 2016)*, Amsterdam, Netherlands, 2016-08-30/31, pp. 209-218. Paris: Atlantis Press. Available [viewed 2020-03-24] at: . Available [viewed 2020-03-24] from: .
+- [b-Malmodin 2018a] Malmodin, J., Lundén, D. (2018). The energy and carbon footprint of the global ICT and E&M sectors 2010–2015. *Sustainability* **10**(9), 3027. Available [viewed 2020-03-29] at
+- [b-Malmodin 2018b] Malmodin, J., Lundén, D. (2018). The energy and carbon footprint of the global ICT and E&M sectors 2010–2015 – Supplementary material. *Sustainability*. Available [viewed 2020-03-29] from:
+
+- [b-Malmodin 2018c] Malmodin, J., Lundén, D. (2018). *The electricity consumption and operational carbon emissions of ICT network operators 2010-2015*. Stockholm: KTH Centre for Sustainable Communications. 13 pp. Available [viewed 2020-03-29] at:
+- [b-Malmodin 2018d] Malmodin, J.; Bergmark, P.; Matinfar, S. (2018). A high-level estimate of the material footprints of the information and communication technology and the entertainment and media sectors. In: Penzenstadler, B., Easterbrook, S., Venters, C., Ahmed, S.I. (editors). *Proceedings of the 4th International Conference on ICT for Sustainability (ICT4S)*, Toronto, ON, Canada, 2018-05-13/14. *EPiC Series in Computing*, vol. 52, pp. 168-186. Available [viewed 2020-03-29] at:
+- [b-Olivia] Olivia (Internet). *2G shutdown: When and where is it happening*. Amsterdam: Olivia. Available [viewed 2020-03-29] at: ,
+- [b-Olivier] Olivier, J.G.J., Schure, K.M., Peters, J.A.H.W (2017). *Trends in global CO2 and total greenhouse gas emissions: 2017 Report*; The Hague: PBL Netherlands Environmental Assessment Agency. 69 pp. Available [viewed 2020-03-30] at: [https://www.pbl.nl/sites/default/files/downloads/pbl-2017-trends-in-global-co2-and-total-greenhouse-gas-emissions-2017-report\\_2674\\_0.pdf](https://www.pbl.nl/sites/default/files/downloads/pbl-2017-trends-in-global-co2-and-total-greenhouse-gas-emissions-2017-report_2674_0.pdf)
+- [b-OMDIA 2020a] OMDIA (2020). Homepage. London: Informa. Available [viewed 2020-03-29] at:
+- [b-OMDIA 2020b] OMDIA (2020). *Fixed broadband connections forecast: 2019–24*. London: Informa. Available [viewed 2020-04-21] at:
+- [b-OMDIA 2020c] OMDIA (2020). *Desktop monitor market tracker*. London: Informa. Available [viewed 2020-03-29] at:
+- [b-OMDIA 2020d] OMDIA (2020). *Public display market tracker*. London: Informa. Available [viewed 2020-03-29] at:
+- [b-OMDIA 2020e] OMDIA (2020). *Security technology*. London: Informa. Available [viewed 2020-03-29] at:
+- [b-OMDIA 2020f] OMDIA (2020). *Small medium display market tracker*. London: Informa. Available [viewed 2020-03-29] at:
+- [b-Point Topic] Point Topic. *The leading resource for worldwide broadband, IPTV and VoIP market intelligence*. London: Point Topic. Available [viewed 2020-03-31] at: ( )
+- [b-SBT Foundations] Science-Based Targets (2019). *Foundations of science-based target setting*, Version 1.0. 44 pp. Available [viewed 2020-03-25] at:
+
+- [b-SBT Manual] Science-Based Targets (2019). *Science-based target setting manual*, Version 4.0. 72 pp. Available [viewed 2020-03-25] at: .
+- [b-SBT Methods] Science-Based Targets (Internet). *Methods*. Available [viewed 2020-03-27] at:
+- [b-SBT Criteria] Science-Based Targets (2019). *SBTi criteria and recommendations*, Version 4.0. 11 pp. Available [viewed 2020-03-25] at:
+- [b-SBT SDA] Science-Based Targets (2015). *Sectoral decarbonization approach (SDA): A method for setting corporate emission reduction targets in line with climate science*, Version 1. 104 pp. Available [viewed 2020-03-25] at:
+- [b-Shehabi] Shehabi, A., Smith, S.J., Sartor, D.A., Brown, R.E., Herrlin, M., Koomey, J.G., Masanet, E.R., Horner, N., Azevedo, I.L., Lintner, W. (2016). *United States Data Center energy usage report*. Berkeley, CA: Lawrence Berkeley National Laboratory. 56 pp. Available [viewed 2020-03-29] at:
+- [b-Stobbe] Stobbe, L., Proske, M., Zedel, H., Hintemann, R., Clausen, J., Beucker, S. (2015). *Entwicklung des IKT-bedingten Strombedarfs in Deutschland* [Development of ICT-related electricity demand in Germany]. . Berlin: Bundesministeriums für Wirtschaft und Energie [Federal Ministry for Economic Affairs and Energy]. 250 pp. Available [viewed 2020-03-30] at: [https://www.bmwi.de/Redaktion/DE/Downloads/E/entwicklung-des-ikt-bedingten-strombedarfs-in-deutschland-abschlussbericht.pdf?\\_\\_blob=publicationFile&v=3](https://www.bmwi.de/Redaktion/DE/Downloads/E/entwicklung-des-ikt-bedingten-strombedarfs-in-deutschland-abschlussbericht.pdf?__blob=publicationFile&v=3)
+- [b-Telia] Telia Company (Internet). *2G and 3G networks to retire – Norway first out*. Solna: Telia Company. Available [viewed 2020-03-30] at:
+- [b-UNFCCC PA] United Nations Framework Convention on Climate Change (2015). *Paris agreement*. New York, NY: United Nations. 27 pp. Available [viewed 2018-11-16] at: [https://unfccc.int/sites/default/files/english\\_paris\\_agreement.pdf](https://unfccc.int/sites/default/files/english_paris_agreement.pdf)
+- [b-Urban] Urban, B., Shmakova, V., Lim, B., Roth, K. (2014). Energy consumption of consumer electronics in US homes in 2013: Final report to the Consumer Electronics Association (CEA). Boston, MA: Fraunhofer USA Center for Sustainable Energy Systems. 158 pp. Available [viewed 2020-03-30] at:
+- [b-US EIA] US EIA (2019). *EIA projects global energy-related CO2 emissions will increase through 2050* Washington, DC: Energy Information Administration. Available [viewed 2020-03-25] at: [https://www.eia.gov/todayinenergy/detail.php?id=41493&utm\\_source=feedburner&utm\\_medium=feed&utm\\_campaign=Feed%3A+eiaite+%28Today+in+Energy%29/](https://www.eia.gov/todayinenergy/detail.php?id=41493&utm_source=feedburner&utm_medium=feed&utm_campaign=Feed%3A+eiaite+%28Today+in+Energy%29/)
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1502-201511-I_PDF-E/raw.md b/marked/L/T-REC-L.1502-201511-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..7de1c3060d09a282cd8cbebd827e248e01c2a15a
--- /dev/null
+++ b/marked/L/T-REC-L.1502-201511-I_PDF-E/raw.md
@@ -0,0 +1,445 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1502**
+
+(11/2015)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+---
+
+**Adapting information and communication
+technology infrastructure to the effects of
+climate change**
+
+Recommendation ITU-T L.1502
+
+
+
+# Recommendation ITU-T L.1502
+
+# Adapting information and communication technology infrastructure to the effects of climate change
+
+## Summary
+
+Information and communication technologies (ICTs) can be part of the solution to climate change by, for example, helping countries adapt to the effects of climate change. At the same time, ICT equipment and infrastructure are themselves exposed to the effects of climate change and therefore need to be both robust and resilient.
+
+Recommendation ITU-T L.1502 identifies direct and indirect threats of climate change on ICT services and provides options for adaptation and mitigation. These threats include extreme rainfall, flooding, landslides, extreme wind, lightning, extreme humidity, drought, ice storms and heavy snowfall.
+
+This Recommendation was developed within the framework of Recommendation ITU-T L.1500. It focuses on telecommunication networks and infrastructure.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1502 | 2015-11-29 | 5 | 11.1002/1000/12629 |
+
+## Keywords
+
+Adaptation, climate change, ICT, information and communication technology, infrastructure, telecommunications.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2016
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|------------------------------------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Adaptation of ICT infrastructure ..... | 2 |
+| 6.1 Impact of climate change on ICT infrastructure..... | 2 |
+| 6.2 Direct consequences of climate change for ICTs ..... | 3 |
+| 6.3 Indirect consequences of climate change for ICTs..... | 8 |
+| 6.4 Checklist..... | 10 |
+| Annex A – Checklist of climate change effect and their impact on ICT infrastructure components ..... | 11 |
+| Bibliography..... | 12 |
+
+
+
+# Recommendation ITU-T L.1502
+
+## Adapting information and communication technology infrastructure to the effects of climate change
+
+## 1 Scope
+
+This Recommendation describes how information and communication technology (ICT) can adapt to or may be adapted to cope with the effects of climate change. It provides a set of requirements and it is to be referred to when planning or upgrading ICT infrastructure to adapt to the effects of climate change.
+
+The term "ICT infrastructure" includes the telecommunication network and its elements such as terrestrial cables, submarine cables, wireless antennas, satellite networks, towers, telecom offices, data centres and customer premises equipment.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T L.3] Recommendation ITU-T L.3 (1988), *Armouring of cables*.
+
+[ITU-T L.26] Recommendation ITU-T L.26 (2015), *Optical fibre cables for aerial application*.
+
+[ITU-T L.46] Recommendation ITU-T L.46 (2000), *Protection of telecommunication cables and plant from biological attack*.
+
+[ITU-T L.67] Recommendation ITU-T L.67 (2006), *Small count optical fibre cables for indoor applications*.
+
+[ITU-T L.1500] Recommendation ITU-T L.1500 (2014), *Framework for information and communication technologies and adaptation to the effects of climate change*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 climate change** [ITU-T L.1500]: Climate change refers to any change in climate over time, whether due to natural variability or as a result of human activity. The Intergovernmental Panel on Climate Change (IPCC) uses a relatively broad definition, referring to a change in the state of the climate that can be identified (e.g., using statistical tests) by changes in the mean and/or the variability of its properties, and that persists for an extended period, typically decades or longer. Climate change may be due to natural internal processes or external forces, or to persistent anthropogenic changes in the composition of the atmosphere or in land use. [b-IPPC SPM]
+
+The IPCC makes a distinction between climate change that is directly attributable to human activities, and climate variability that is attributable to natural causes. For the purposes of this report, either definition may be suitable depending on the context of analysis.
+
+**3.1.2 climate change adaptation** [ITU-T L.1500]: Adaptation to climate change can be defined as the adjustment in ecological, social or economic systems in response to actual or expected climatic stimuli and their effects. It refers to changes in processes, practices and structures to moderate potential harm or benefit from opportunities associated with climate change.
+
+### **3.2 Terms defined in this Recommendation**
+
+None.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+HVAC Heating, Ventilation and Air Conditioning
+ICT Information and Communication Technology
+IPCC Inter governmental Panel on Climate Change
+LAN Local Area Network
+TSP Telecommunications Service Provider
+
+## **5 Conventions**
+
+None.
+
+## **6 Adaptation of ICT infrastructure**
+
+### **6.1 Impact of climate change on ICT infrastructure**
+
+More intense and frequent climatic extremes are expected as a result of climate change. These extremes pose a threat to industries, like the ICT industry that relies on physical infrastructures. There is an increased risk of service disruption to a range of essential services which now depend on ICT.
+
+[b-IPPC 2012] quotes: "Major settlements are dependent on lengthy infrastructure networks for water, power, telecommunications, transport, and trade, which are exposed to a wide range of extreme events (e.g., heavy precipitation and snow, gale winds). Modern logistics systems are intended to minimize slack and redundancies and as a result are particularly vulnerable to disruption by extreme events".
+
+Telecommunication networks and related ICTs must therefore be able to cope with extreme weather events. A more robust and resilient infrastructure may be required in the future than the infrastructure that is in operation today. Costs can be greatly reduced by considering the requirements at the initial design stage rather than by retrospective upgrade. The need for the ICT infrastructure to cope with extremes of climate or adapt to its effects can be considered from two complementary perspectives – the direct and the indirect perspectives.
+
+[b-ITU-T L.92] deals with disaster management for outside plant facilities. It gives an overview of the technical considerations for protecting outside plant facilities from natural disasters. Disaster management for outside plant facilities such as cables, poles and manholes are introduced, and countermeasures for natural disasters such as earthquakes, strong winds and floods are described.
+
+
+
+| Natural Disaster | Percentage |
+|------------------|------------|
+| Earthquake | 22% |
+| Flash floods | 25% |
+| Forest fires | 13% |
+| Strong winds | 22% |
+| Landslides | 6% |
+| Severe cold | 6% |
+| Other | 6% |
+
+Pie chart showing the most destructive natural disasters. The chart is divided into seven segments: Earthquake (22%), Flash floods (25%), Forest fires (13%), Strong winds (22%), Landslides (6%), Severe cold (6%), and Other (6%). The label L.1502(15)\_F01 is present below the chart.
+
+**Figure 1 – Most destructive natural disasters**
+
+As described in [b-ITU-T L.92], sixteen countries responded to a questionnaire on the protection of outside plant facilities from natural disasters. One of the results of the questionnaire is shown in Figure 1, which ranks natural disasters according to their destructiveness. Most of these natural disasters can be expected to become more frequent as a result of climate change. Note however that the relationship between climate change and earthquakes is being considered, but has yet to be acknowledged by the IPCC [b-IPPC Quake].
+
+In addition to these effects, this Recommendation also considers the risks to ICT infrastructure posed by more extreme changes in temperature, humidity, drought, ice storms and heavy snowfall, and considers ways to make the infrastructure more robust so as to reduce the impact of natural disasters.
+
+### 6.2 Direct consequences of climate change for ICTs
+
+Direct effects of climate change on ICTs include the vulnerability of ICT equipment to extreme weather events such as increased flooding, wind speed, precipitation, humidity, temperature, snow and ice fall and lightning strikes.
+
+The ICT infrastructure includes telecommunication centres, outside plants, data centres, base stations and user terminals, including handsets. The ICT devices making up this infrastructure are designed to operate within specified ranges of temperature and humidity, and need protection against dust and/or water ingress. When ICT devices operate outside their specified environmental conditions, they are at risk of malfunction, failure and/or damage.
+
+Most ICT services depend upon an end-to-end connection to be maintained for their operation. Telecommunication service providers (TSPs) and other network-based industries are applying techniques such as redundancy (of equipment and of path) to avoid single points of failure which could disrupt service. Such redundancy is usually applied to trunk routes where many users share a common path. This does not totally remove the risk of failure and many parts of the network remain unprotected and are thus vulnerable to climate change-related weather events.
+
+TSPs are significantly exposed to physical risks since extreme weather conditions could result in network damage, restoration costs, loss of revenue and rising insurance costs. Network-based service providers may have to consider protecting or relocating elements of their network that could become exposed to damage from severe weather conditions. This is particularly true in the case of remote sites, especially in developing countries, where road access to the sites is needed for access and maintenance and often for providing energy supplies.
+
+Operators have already begun taking into consideration climate change when planning the location of new central nodes for next generation networks.
+
+Wireless technologies may be seen as more resilient, and could fare better than fixed networks when climate-related events strike, although their backhaul is becoming increasingly dependent on the higher capacity of fixed network technology such as optical fibre. As ITU has noted, "In many cases, when disaster strikes the "wired" telecommunication infrastructure is significantly or completely destroyed and only radio communication services can be employed for disaster relief operation (especially amateur radios and satellite systems) [b-ITU Climate]."
+
+#### 6.2.1 Temperature
+
+The failure rate of an electrical component increases exponentially with temperature. Each component has an activation energy that is characteristic of its chemical composition. Failure will result when the temperature rises sufficiently to cause breakdown in the chemical or crystal lattice. Components are therefore highly underrated so that they operate in a statistically "safe" temperature range [b-ITU Adapt]. Since ICT equipment and facilities usually require proper cooling for their performance management, longer and more intense heat waves, high temperature atmosphere and long tropical nights increase the risk of performance degradation and even device failure.
+
+Semiconductor parts are most often specified for use in the "commercial" 0-70°C and, to a lesser extent, in the "industrial" -40 to +85°C operating temperature ranges. These ranges generally satisfy the demands of the computer, telecommunication and consumer electronic industries. Some components such as processors are designed to run "hot": perhaps 50°C or more above ambient temperature. For a desktop personal computer, the cooling system may be no more than a heat-sink and fan blowing air at ambient temperature to avoid thermal breakdown. For mass deployments, such as in telecommunications buildings and data centres, liquid cooling systems may be used. However, many are or will be using ambient air cooling. Climate change may give rise to a higher ambient air temperature than was originally planned which in turn could necessitate an upgrade of the cooling system. Equipment stored outdoors (e.g., cabinets and shelters) are more subjected to the external temperature changes compared to indoor equipment. Such equipment could experience up to 65 degrees Celsius inlet temperature [b-temp].
+
+#### 6.2.2 Extreme rainfall/flooding
+
+Telecommunications buildings and infrastructure can be at risk from extreme rainfall and flooding, depending on their location. This risk may increase in frequency or severity as a result of climate change. If the electricity grid fails, the backup power systems may also become awash, and power can then only be maintained by other backups such as batteries, if available, for a limited period, and only for emergency services. The risk of this happening would have been taken into account in the design and build of the central office, but the impact of climate change requires the statistics to be updated to show a higher probability of the event occurring, and today perhaps 1 in 100 years would be a better estimate for planning purposes. It should be noted that severe climate events, are now happening much more frequently than in the past.
+
+Possible remedial work to make central offices less vulnerable to flooding would be to raise equipment from the ground floor to higher floors. This has already happened in many instances when obsolete electromechanical switches were replaced by physically smaller digital switches, causing complete floors to be vacated. Problems remain as, typically, the ingress of electrical energy is located at ground (or even underground) level. Large telecommunication sites (typically in cities) have large batteries that could be as much as 10,000Ah @48V. Due to their weight, to cope with the building's structural stability needs, such batteries are typically installed at ground/underground level which may be subject to flooding.
+
+An evolutionary step, which eliminates the need for central offices, is the location of ultra-broadband equipment in roadside cabinets or a shelter that, for economical reasons, are typically installed outdoors at ground level. This step leads to issues regarding water ingress to these cabinets or shelters which may or may not, be protected against flooding. Possible remedial work could be to
+
+move street cabinets to a higher level or the use of waterproof solutions if the risk of flooding is known to have increased due to climate change.
+
+A further step would be to check the location of the backup generator and heat exchangers for air-conditioning units. For practical and operational reasons, these are often located outside the main building near ground level. Raising their level or applying techniques resilient to floods should be considered, with due consideration to other factors such as weight, loading and vibration.
+
+Fixed access and trunk networks are often buried alongside roads or railway lines. Whereas the trunk network is likely to be protected by alternative routing, the access network remains vulnerable to a single point of failure. Roadside passive cabinets are generally not sealed against water rising from below and contain manual flexibility points where open wires can come into contact with flood water. Flooding can lead to these becoming unserviceable until the flooding subsides. Corrosion due to flood water after water recedes can also contribute to a loss of service.
+
+New technologies with gigabit transmission along twisted pairs such as fibre to pedestal or distribution point (i.e., at a location closer to customer premises), are being introduced into telecommunication networks [b-ITU-T G.9701]. The use of optical fibre in the access network and shorter twisted pair lines will increase transmission speeds and reduce the risk of problems due to moisture and flooding, provided that the electronic components are protected from environmental damage, by for example, water ingress. Fibre to the premises is an option which further reduces the risk of damage due to flooding or from extreme rainfall.
+
+Many mobile network base stations are located at high points to provide optimum coverage and therefore the risk of flooding is reduced. Care needs to be taken when equipment is located on flood plains so that the base station equipment and generator are raised above ground level.
+
+When mobile backhaul networks use point-to-point microwave links between towers, these are liable to outage during storms. Raindrops scatter the microwave signal and can cause a loss of service. A system margin is applied so that the power is sufficient in all but the most severe conditions. An estimate of the margin needed to allow for rainfall can be found in [b-ITU-R P.530-9]. To this must be added the free space propagation loss and losses due to pointing variation with high winds. There is a need to know the maximum rainfall and wind speed before the margin can be calculated, which will depend upon rainfall measurements in the locality. As a result of climate change, more extreme rainfall can be expected and so the margin may need to be increased. This is a topic for further study. However, fibre optical cables are now being laid between towers to replace microwave or copper in order to increase the capacity of the networks, and this will eliminate the risk of link loss due to rainfall.
+
+#### 6.2.3 Landslides
+
+Telecommunication lines are frequently laid along roadsides which are vulnerable to landslides in some areas.
+
+The risk of landslides and avalanches is increasing due to deforestation and climate change. Facilities such as telecommunication cables located near risk areas are therefore becoming more vulnerable. Maps have been produced for most countries and regions which show the risk by colour code. Landslides can be caused by the over steepening or overloading of slopes, earthquakes, tsunamis, hurricanes, flooding, erosion and other severe weather events, or by vegetation loss as a result of logging, development or wildfires. Landslides can be caused also by various erosions such as rain splash erosion, lateral erosion in river sides and coastal erosion by the sea level rise. Base stations may be destroyed by such erosion cases. Mitigation measures include planting ground cover (low growing plants) on slopes.
+
+Rainfall thresholds for the initiation of landslides have been studied. Regional and local thresholds perform reasonably well in the area where they were developed, but cannot be easily exported to neighbouring areas. Global thresholds are relevant where local or regional thresholds are not
+
+available, but may result in (locally numerous) false positives, i.e., prediction of landslides that do not occur.
+
+Landslides could cause telecommunication poles to fall, bringing down aerial cables. Soil erosion is a problem in some areas particularly when reclaimed land is at or below sea level.
+
+#### **6.2.4 Extreme winds**
+
+ICT facilities at risk of damage include buildings, overhead lines and antennae. Overhead lines provide fixed access connectivity at lower cost than underground ones, but the cables are vulnerable to the effects of wind through damage by falling trees and gradual wear out due to metal fatigue and vibration [ITU-T L.26]. In areas more prone to falling trees, the route of new overhead lines should be kept at reasonable distance from trees. When this is not possible (existing overhead lines or forest crossing), trees close to the line should be cut to form a safety zone, same as what is today done for the electricity overhead lines.
+
+Antennae are at risk due to winds exceeding their design limit such as the ability to withstand 70 m/s (252 km/h) wind speed. The IPCC Fourth Assessment Report [b-IPCC 4th AR] says that "Based on a range of models, it is likely that future tropical cyclones (typhoons and hurricanes) will become more intense, with larger peak wind speeds and heavier precipitation associated with ongoing increases of tropical sea-surface temperatures". The report states that there is low confidence in wind speed model trends other than for tropical cyclones. Overall, the changes do not appear to be very large so that adaptation measures may not be necessary in the ICT sector except where there is a risk of cyclone.
+
+In some locations, such as the pacific island of Guam, the IPCC Special Report [b-IPCC SR] states that buildings are required to withstand peak gust wind speeds of 76 m/s, expected every few decades (International Building Codes, 2003). This higher limit could be applied to ICT buildings and antennae in risk areas. The latest version of the International Building Code is available online. Chapter 1612 of the [b-IPCC SR] includes maps of rainfall, seismic, snow and wind criteria across the USA. In general, coastal regions can be expected to have higher maximum wind speeds.
+
+Wind load is proportional to the square of the wind speed. If the wind speed increases by 10% in a region as a result of climate change, then the load acting on a structure will increase by 20%. It is therefore important to monitor the latest building regulations for the region and consider if the wind speeds and loads quoted are sufficient for the life of the building, which could be a century or more.
+
+Whilst care must be taken when designing antennae to ensure safety to persons, pointing accuracy also must be considered. If the mast carries highly directional antennae such as microwave dishes, the structure must be able to maintain pointing accuracy. In some cases, a 0.1 degree displacement will be sufficient to cause a loss of service. In a storm both ends of the link are likely to be affected. System margin therefore needs to be added to allow for losses due to wind and pointing accuracy. Excess wind is normally allowed for in the antenna and mast design so that no permanent bending occurs in the structure. After the storm is over, the signals should then return to normal level. In the context of adaptation to climate change, it would be wise to consider a 20% stiffening of the structure over current building regulations to allow for the possible 10% increase in extreme wind over the coming decades.
+
+#### **6.2.5 Lightning**
+
+The risk of damage to equipment at telecommunication sites due to lightning can be assessed by risk analysis. ITU-T has published ten K-series Recommendations on this topic (see the bibliography).
+
+More research is needed to determine if, in order to take climate change into account, the values of the parameter 'number of strikes per year' need to be increased (or decreased) with respect to the values on keraunic (lightning strike) maps for the locality.
+
+Adequate grounding is necessary. If changes in climate and weather patterns occur, soil moisture content and resistivity will change as well, and prolonged drought could cause significant increase in grounding resistance, even beyond safety limits. This can affect the safety of maintenance workers, the resilience of infrastructure to lightning, and the performance of power supply systems and telecommunication networks. It may therefore be necessary to install additional protection in some locations.
+
+In mains-powered cabinets and remote base stations, an increase in the grounding resistance or an increase in the frequency and strength of lightning could cause an increase in the residual current circuit breaker trips. This could cause prolonged service disruption as a truck roll is normally required to reset the circuit breaker. To increase resilience against these unwanted power breaks, it is advisable to install either high-noise-immunity differential switches (reinforced immunity) or self-restoring breakers. Self-restoring breakers typically include a control system that verifies the integrity of the system and prevent reactivation if a permanent fault is detected, such as a ground fault caused by a breakdown of the insulation.
+
+#### **6.2.6 Humidity**
+
+Humidity can affect the reliable operation of ICT systems. Effects such as corrosion under high humidity and damage due to static electricity under low humidity are well known. Most important is condensation which occurs when there is a change from a cold environment to a warm and humid one such as when a device is moved in winter from outdoors to an indoor heated room.
+
+More work is needed to determine the direct impact of extreme humidity on ICT infrastructure. However, there may be an indirect impact on the workforce required to install and maintain networks. "The combination of high temperature and humidity in some areas for parts of the year is expected to compromise common human activities, including growing food and working outdoors (high confidence)." [b-IPCC 2014].
+
+#### **6.2.7 Drought**
+
+Drought is illustrated by dry, cracked earth; low reservoir levels; barren fields. There are different types of drought though, each of which is measured differently. The meteorological drought is reflected by levels of precipitation, assessment of the degree of dryness (in comparison to a local or regional average) and the duration of the dry period. There is also hydrological drought, or how decreased precipitation affects stream-flow, soil moisture, reservoir and lake levels, and groundwater recharge. Agricultural drought occurs when water supplies are not able to meet crop water demands.
+
+The changes in precipitation regimes can lead to long periods of drought, increasing the risk of subsidence, hence affecting the stability of foundations and tower structures. Corrosion rates can result from this phenomenon and require different equipment maintenance schemes for ICTs. This could lead to the degradation of ICT infrastructure, business cost and safety risks to personnel.
+
+Some telecommunication installations have a pond nearby to provide water to extinguish fires. The level of this pond must be maintained to cope with extreme drought conditions.
+
+Among the cooling technologies used in ICT plants there are some that need large amounts of water in the refrigeration cycle. For large sites water is used in the heat exchangers, while in other sites evaporative cooling is increasingly used. In case of drought, this raises the problem of possible diversion of water from the needs of the population. Lack of water would be critical to such cooling systems as lack of water would stop their functioning, with the consequent increase of temperature to the ICT equipment. This could cause malfunction of the ICT service and even failure.
+
+#### **6.2.8 Ice storms and heavy snowfall**
+
+Ice storms and heavy snowfall can cause failure of electricity transmission lines, causing power outage of ICT services through a lack of local supply. These weather events can also be responsible
+
+for damage to the telecommunication lines, for example, when a branch breaks from a tree onto a telephone line and when ice forms around the aerial cable, increasing its weight and its surface exposed to wind (more stress). Radio systems are affected when antennae are covered in ice.
+
+The IPCC [b-IPPC 2014] have reported that "There is very high confidence that the extent of Northern Hemisphere snow cover has decreased since the mid-20th century by 1.6 [0.8 to 2.4]% per decade for March and April, and 11.7% per decade for June, over the 1967 to 2012 period."
+
+However, it seems likely that extreme events are increasing as a consequence of climate change. A recent example of the consequences of ice storms is noted in the New York area. The ClimAID Report includes a chapter on Telecommunications [b-ClimAid]. It says: "The December 2008 ice storm in New England and Central and Upstate New York formed late on December 11 and dissipated meteorologically by December 12. Its impact, however, lasted for more than a week in New York and in large portions of New England Telecommunications services were disrupted as a result of damaged lines, and electronic equipment in homes lost power. Cable-provided voice, video, and data services had problems at twice the normal levels during the week following the storm. Damage was primarily a result of fallen trees, utility wires, and poles, which were coated in a heavy layer of ice. The slow return of power in the aftermath of the storm resulted in a great deal of controversy about why the utilities could not restore services more expediently, if not avoid outages in the first place."
+
+#### 6.2.9 Species damage
+
+It is known that damage to telecommunication infrastructure such as cables, either buried or laid on the ground, may be caused by:
+
+- mammals, squirrels, mice, rats, moles, gophers and other rodents
+- birds like woodpeckers and cockatoos
+- insects such as termites, ants, beetles, wasps and caterpillars
+- micro-organisms like bacteria, fungus and/or moulds.
+
+In areas where these species are normally active, their effects are known and measures can be taken to counter their effects. However, climate change is causing animal and plant species to migrate, usually northwards in the Northern hemisphere and southwards in the Southern hemisphere, and sometimes to increase their overall range. Therefore, they may become active in areas where they have not previously been present, and measures may need to be taken to counter their impact in new areas.
+
+Measures that can be taken to protect fibre optic cables against damage include polyamide protection and helically applied steel tape armour [ITU-T L.3], [ITU-T L.26], [ITU-T L.46] and [ITU-T L.67].
+
+### 6.3 Indirect consequences of climate change for ICTs
+
+Indirect effects of climate change on ICTs and the additional consequences of climate change impacts include increases in operators' energy demands, as higher temperatures will, under the current increasing temperatures, require more air conditioning in the exchanges. Network damage will require trucks to be used for repairs, with implications for fuel use. Operators are also likely to have to run more back-up generators in areas experiencing extreme weather conditions.
+
+Where sea levels are expected to rise materially, and rivers to flood due to severe rainfalls, network operators would likely be required to move or to replace a significant amount of network equipment. For example, equipment positioned in sites at risk of flooding would need repositioning, and displaced populations would likely require new networks to be built. In countries like Bangladesh, more than a fifth of the territory could be under water with a one-metre rise in sea levels, highlighting the risk to telecommunication companies in such regions. In other words, it is
+
+likely that the consequences of climate change will be very different for TSPs in different regions, and that the requirements for adaptation will, as a consequence, also be different.
+
+The data centres, server farms and hosting environments that have become an essential part of the ICT ecosystem have very demanding requirements for electricity and air conditioning. Such facilities have become essential for the delivery of many telecommunication-based services and applications. Thus, adaptive and remedial actions related to the energy-efficient supply of data centres need to be considered [b-ITU-T L.1300].
+
+The chronic effects of climate change may not give rise to an immediate catastrophic failure but have a more indirect impact that can degrade the performance of the service or system. The following are key areas where chronic climate change manifestations can have an impact, and therefore, where adaptive measures are also required:
+
+#### **6.3.1 Vehicles and climate change adaptation**
+
+The ICT sector uses vehicles to maintain supply, operation and disposal of devices and infrastructure. The vehicle fleet should therefore be included in climate change adaptation risk assessments as it is exposed to environmental vulnerabilities. However, it is not considered to be within the scope of this Recommendation to cover the performance of the transport sector. ICT experts are not normally involved in maintaining the vehicle fleet but may be responsible for driving and personal safety. They should therefore be aware of weather conditions, be especially alert for extreme weather events and take note of local forecasts before making a journey.
+
+#### **6.3.2 Workforce and climate change adaptation**
+
+The ICT sector ultimately depends upon its workforce to maintain supply, operation and disposal. The workforce is also vulnerable to climate change events such as when making the journey to work. Occasionally, the transport systems fail due to extreme weather and it may not be possible to reach the workplace. Opportunities for remote working should therefore be explored. Ofcom [b-Ofcom] noted that remote working is becoming common practice as an alternative to travel to fixed offices.
+
+#### **6.3.3 Supply chain and climate change resilience**
+
+The supply chain provides new and replacement technology and maintenance services to the ICT sector. Normally suppliers are not in the critical path for day-to-day network operation but they are responsible for providing new equipment and ensuring maintenance of equipment in service.
+
+Network devices may have an asset life of 2 to 13 years and ICT office devices 3 to 6 years from an accounting perspective. There is rapid turnover of equipment as new generations of equipment are introduced with increased capability due to advances made possible by Moore's law. The supply chain can therefore respond to the list of adaptation options listed above by introducing new features to enhance resilience and ensure a smooth adaptation to climate change.
+
+From the maintenance perspective, specialist technicians make regular inspections of HVAC systems. During an inspection, a check can be made on the ability of the equipment to cope with the thermal load as noted in clause 6.2.1. This may increase beyond the design limit due to new equipment being added or if a change in extreme temperature is anticipated.
+
+Suppliers may be vulnerable to extreme climate effects which could cause problems in the distribution of replacement or new equipment especially during times of disaster. Operators and suppliers therefore need to examine the handling of disaster recovery by taking account of possible scenarios and their associated response times with a focus on possible transport problems brought about by disasters related to climate change or other causes.
+
+#### 6.3.4 ICT end-user services and equipment
+
+End users normally have no expertise and control over their ICT devices and services, yet they are becoming increasingly dependent upon devices in order to carry out their daily lives. Smartphones (Internet connected) have recently overtaken feature (voice/text) phones in global sales. This makes end users particularly vulnerable to the effects of failure due to climate change or other disasters.
+
+It is therefore important that end users understand the risks and mitigation options. Common failure modes include:
+
+- failure of the device (e.g., overheating/dropping/moisture ingress)
+- failure of the network (e.g., overload/accessibility)
+- loss of power (e.g., battery failure/grid supply failure).
+
+Climate change can increase the vulnerability of user equipment but may not be a primary cause of failure.
+
+Resilience can be increased by ensuring diversity is available. Examples include:
+
+- Maintain access to two devices which can be connected to more than one different type of network (fixed/mobile/satellite and broadcast devices such as radio and TV receivers).
+- Maintain connectivity to alternative access networks by taking advantage of communal or shared wireless local area network (LAN) services.
+- Maintain a source of off-grid power (e.g., car battery with power derived from the cigarette lighter socket). For those without cars, a battery may be charged using a solar panel. These can be purchased for a number of applications including mobile phones and small device chargers and those for use in caravans or boats.
+- Ensure TV and radio receiver antennae are able to operate under extreme weather conditions (wind, extreme rainfall and interference during ducting conditions).
+- Continuity of broadcast information services can be made more resilient by using both terrestrial and satellite systems.
+
+### 6.4 Checklist
+
+Table A.1 is a matrix of climate change effects and their impact on ICT infrastructure components. Risks have been classified according to their severity: low, medium and high.
+
+Network planners may use this as a guide to the identification and minimization of effects to ensure survivability of the network under extreme weather conditions.
+
+## Annex A
+
+### Checklist of climate change effects and their impact on ICT infrastructure components
+
+(This annex forms an integral part of this Recommendation.)
+
+Table A.1 is a matrix of climate change effects and their impact on ICT infrastructure components. Risks have been classified according to their severity: low, medium and high. Network planners may use this as a guide to the identification and minimization of effects to ensure survivability of the network under extreme weather conditions.
+
+**Table A.1 - Matrix of climate change effect and their impact on ICT infrastructure components**
+
+| Effect Infrastructure | Temperature rise | Humidity | Wind loading | Sea level rise | Rainfall | Floods | Land slides | Snow and Ice fall | Lightning strikes | Species damage |
+|---------------------------------|------------------|----------|--------------|----------------|----------|--------|-------------|-------------------|-------------------|----------------|
+| Tower | L | L | H | M | L | H | M | L | H | L |
+| Antenna | M | M | H | L | H | M | M | H | H | L |
+| Electronics | H | H | L | L | M | L | L | L | H | L |
+| Equipment room | M | M | L | H | H | H | L | L | H | L |
+| Fibre Optic | L | L | L | L | L* | L | H* | L | L | M |
+| Twisted pair and coaxial cables | L | L | H | M** | M | H | H** | M | H | H |
+| Grid supply | L*** | L | L | M | M | H | M | M | H | M |
+| Standby generators | L | L | L | M** | M | H | H** | H | M | L |
+| Satellite Earth Stations | L | L | H | M | H/M | M | M | H | H | L |
+| HVAC | H | M | L | L | L | L** | L | L | L | L |
+
+L: Low; M: Moderate; H: High
+
+\* The fibre optic installation should take note of the risk of landslides and heavy rainfall; their respective installation should avoid areas with a high risk of landslides.
+
+\*\* Location dependent.
+
+\*\*\* Demands on grid supply may increase beyond its capacity when temperatures rise due to more requirements for cooling.
+
+## Bibliography
+
+- [b-ITU-T G.9701] Recommendation ITU-T G.9701 (2014), *Fast access to subscriber terminals (FAST) – Physical layer specification*.
+- [b-ITU-T L.92] Recommendation ITU-T L.92 (2012), *Disaster management for outside plant facilities*.
+- [b-ITU-T L.1300] Recommendation ITU-T L.1300 (2014), *Best practices for green data centres*.
+- [b-ITU-R P.530-9] Recommendation ITU-R P.530-9 (2001), *Propagation data and prediction methods required for the design of terrestrial line-of-sight systems*.
+- [b-ITU Adapt] International Telecommunication Union ITU-T (2014), *Resilient pathways: the adaptation of the ICT sector to climate change*.
+[http://www.itu.int/en/ITU-T/climatechange/Documents/Publications/Resilient\\_Pathways-E.PDF](http://www.itu.int/en/ITU-T/climatechange/Documents/Publications/Resilient_Pathways-E.PDF)
+- [b-ClimAID] ClimAID 2011, *Responding to Climate Change in New York State*, Chapter 10 Telecommunications (2011),
+
+- [b-ITU climate] International Telecommunication Union, 2008, *ITU and Climate Change*.
+
+- [b-IPPC Quake] *IPCC Studies Link Between Warming and Earthquake Activity Climatequake: Will global warming rock the planet?*
+
+- [b-IPCC SR] IPCC Special Report on "Managing the risks of extreme events and disasters to advance climate change adaptation"
+[http://www.ipcc-wg2.gov/SREX/images/uploads/SREX-All\\_FINAL.pdf](http://www.ipcc-wg2.gov/SREX/images/uploads/SREX-All_FINAL.pdf)
+- [b-IPCC 4th AR] IPCC 4th Assessment Report *Climate Change 2007: Synthesis Report* page 33,
+[http://www.ipcc.ch/pdf/assessment-report/ar4/syr/ar4\\_syr.pdf](http://www.ipcc.ch/pdf/assessment-report/ar4/syr/ar4_syr.pdf)
+- [b-IPPC 2012] IPCC Special Report (2012), *Managing the risks of extreme events and disasters to advance climate change adaptation*
+[http://ipcc-wg2.gov/SREX/images/uploads/SREX-All\\_FINAL.pdf](http://ipcc-wg2.gov/SREX/images/uploads/SREX-All_FINAL.pdf)
+- [b-IPPC 2014] IPCC (2014), *Climate Change 2014 – Synthesis Report, page 15*
+[https://www.ipcc.ch/pdf/assessment-report/ar5/syr/SYR\\_AR5\\_FINAL\\_full.pdf](https://www.ipcc.ch/pdf/assessment-report/ar5/syr/SYR_AR5_FINAL_full.pdf)
+- [b-Ofcom] Ofcom, UK *The availability of communications services in the UK*,
+
+- [b-ITU-T K-ser] ITU-T Recommendations in the K-series (39, 46, 47, 56, 67, 85, 89, 92, 101 and 105)
+ (entries for each recommendation)
+- [b-temp] News clip (1 June 2015)
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.1505-201801-I_PDF-E/raw.md b/marked/L/T-REC-L.1505-201801-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..0e8c251d6de1b73c63864059786d819ebf7217bc
--- /dev/null
+++ b/marked/L/T-REC-L.1505-201801-I_PDF-E/raw.md
@@ -0,0 +1,938 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.1505**
+
+(01/2018)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+---
+
+**Information and communication technology and
+adaptation of the fisheries sector to the effects
+of climate change**
+
+Recommendation ITU-T L.1505
+
+# ITU-T L-SERIES RECOMMENDATIONS
+
+## **ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+### **OPTICAL FIBRE CABLES**
+
+| | |
+|-------------------------------------|-------------|
+| Cable structure and characteristics | L.100-L.124 |
+| Cable evaluation | L.125-L.149 |
+| Guidance and installation technique | L.150-L.199 |
+
+### **OPTICAL INFRASTRUCTURES**
+
+| | |
+|--------------------------------------------------------|-------------|
+| Infrastructure including node elements (except cables) | L.200-L.249 |
+| General aspects and network design | L.250-L.299 |
+
+### **MAINTENANCE AND OPERATION**
+
+| | |
+|-------------------------------------------------|-------------|
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+
+### **PASSIVE OPTICAL DEVICES**
+
+| | |
+|-------------------------|-------------|
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+|-------------------------|-------------|
+
+### **MARINIZED TERRESTRIAL CABLES**
+
+| | |
+|------------------------------|-------------|
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+|------------------------------|-------------|
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T L.1505
+
+## Information and communication technology and adaptation of the fisheries sector to the effects of climate change
+
+## Summary
+
+Climate change will affect both fish stocks and their habitats. Rising or falling temperatures will influence the abundance, migratory patterns and mortality rates of wild fish stocks and determine what species can be farmed in specific regions. Climate change can lead to changes in the volume of water in rivers and lakes. The composition of water bodies can affect the species and quantities of fish stocks. These climatic effects on fish stocks will have social and economic consequences for people dependent on fisheries and aquaculture ranging from fisheries workers to coastal communities as well as to the consumers of fish.
+
+Recommendation ITU-T L.1505 includes a review of the effects of climate change on fisheries and fishing communities. It recognizes the need for adaptation and for the use and dissemination of relevant innovative techniques. It explores adaptation plans and the potential role of information and communication technologies (ICTs) in supporting the adaptation of the fisheries sector to cope with the effects of climate change.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.1505 | 2018-01-13 | 5 | 11.1002/1000/13460 |
+
+## Keywords
+
+Adaptation, climate change, ecosystem, fisheries, ICT.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+### INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2018
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+###### Page
+
+| | | |
+|-------------|-------------------------------------------------------------------------------------------------------------------------------------------|----|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| 3.1 | Terms defined elsewhere ..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 2 |
+| 6 | Impacts of climate change on the fisheries sector ..... | 2 |
+| 6.1 | Ecosystem impacts ..... | 2 |
+| 6.2 | Impacts on livelihoods..... | 3 |
+| 6.3 | Economic impact on people ..... | 3 |
+| 7 | Climate change adaptation measures for the fisheries sector ..... | 3 |
+| 8 | The eco-system of the fisheries sector to be involved in adaptation ..... | 5 |
+| 9 | Trends in ICTs which are relevant to the fisheries sector ..... | 5 |
+| 10 | ICT components which are relevant to the fisheries sector ..... | 5 |
+| 11 | How can ICTs help sustain the fisheries sector in the events of climate change ..... | 6 |
+| 11.1 | ICT to monitor site condition ..... | 6 |
+| 11.2 | ICTs to promote knowledge sharing and improve management..... | 6 |
+| 11.3 | ICTs to predict weather and types of fish-catches..... | 6 |
+| 11.4 | ICTs for forecasting..... | 6 |
+| 11.5 | ICTs for leveraging market realities ..... | 6 |
+| 11.6 | ICTs for emergency/alert systems ..... | 7 |
+| 11.7 | ICTs for maritime boundaries ..... | 7 |
+| 11.8 | ICTs for efficient decision-making (example from Lake Victoria) ..... | 7 |
+| 11.9 | Technology for high-accuracy fuel efficiency estimation..... | 7 |
+| Appendix I | – SayadTec application to adapt to climate change effects in the fisheries sector..... | 9 |
+| I.1 | Introduction ..... | 9 |
+| I.2 | SayadTec system description ..... | 9 |
+| I.3 | SayadTec system modules..... | 10 |
+| I.4 | Technologies and tools ..... | 14 |
+| I.5 | Future SayadTec developments..... | 14 |
+| Appendix II | – Fisher friend mobile application (FFMA) A mobile application using ICTs to adapt to climate change effects in the fisheries sector..... | 15 |
+| II.1 | Introduction ..... | 15 |
+| II.2 | FFMA system description ..... | 15 |
+| II.3 | FFMA system features ..... | 15 |
+| II.4 | Impact of FFMA summary ..... | 17 |
+| II.5 | Awards..... | 18 |
+
+| | |
+|-----------------------------------------------------------------------------------------------------------------------------------|----|
+| Appendix III – mKRISHI fisheries A mobile application using ICTs to adapt to climate change effects in the fisheries sector ..... | 19 |
+| III.1 Introduction to the mKRISHI Fisheries application..... | 19 |
+| III.2 mKRISHI system description..... | 20 |
+| III.3 Impact of the mKRISHI application..... | 21 |
+| Appendix IV – Localized weather alert service for fishing villages on Lake Victoria ..... | 22 |
+| Appendix V – Analysis of ship-related big data to estimate fuel efficiency, speed and other performance factors ..... | 24 |
+| V.1 Introduction ..... | 24 |
+| V.2 Background..... | 24 |
+| V.3 Issues ..... | 24 |
+| V.4 About the new technology..... | 25 |
+| V.5 Results ..... | 26 |
+| V.6 Future plans ..... | 26 |
+| Bibliography..... | 27 |
+
+## Introduction
+
+Climate change will affect both fish stocks and their habitats. Warmer or cooler temperatures will influence the abundance, migratory patterns and mortality rates of wild fish stocks and determine what species can be farmed in specific regions. Climate change can lead to changes in the volume of water in rivers and lakes. The composition of a body of water can affect the species and quantities of fish present. These climatic effects on fish will have social and economic consequences for people dependent on fisheries and aquaculture ranging from fisheries workers to coastal communities as well as to the consumers of fish [b-OECD].
+
+The purpose of this Recommendation is to:
+
+- Offer useful information to decision makers concerning areas of possible adaptive action using ICTs in both developing and developed countries in relation to climate change and the fisheries industry.
+- Describe state-of-the-art ICT applications and systems, in addition to hybrid systems where traditional means of dealing with climate change adaptation effects are used hand-in-hand with new technologies in order to reach large and small-scale fishermen and other actors in the fisheries sector speedily and at minimum cost.
+- Provide examples of success stories of the adoption of ICTs usage to adapt the fisheries sector to the events of climate change in order to bring general awareness for possible adoption by others.
+
+Facilitate understanding of the role of ICTs in the fisheries sector for adaptation to climate change, paving the way for the adoption of ICTs to develop climate-smart fisheries, in particular achieving increased productivity and enhanced the resilience of small-scale fishermen despite the events of climate change.
+
+
+
+# Recommendation ITU-T L.1505
+
+## Information and communication technology and adaptation of the fisheries sector to the effects of climate change
+
+## 1 Scope
+
+This Recommendation includes a review of the effects of climate change on fisheries and fisheries communities. It recognizes the need for adaptation and for the use and dissemination of relevant innovative techniques. It explores adaptation plans and the potential of ICTs in supporting the adaptation of the fisheries sector to cope with the effects of climate change with reference to [ITU-T L.1500] and [ITU-T L.1501]. Examples of best practices from different countries on the use of ICT systems and tools to adapt the fisheries sector are also provided in this Recommendation.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T L.1500] Recommendation ITU-T L.1500 (2014), *Framework for information and communication technologies and adaptation to the effects of climate change*.
+
+[ITU-T L.1501] Recommendation ITU-T L.1501 (2014), *Best practices on how countries can utilize ICTs to adapt to the effects of climate change*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 climate change** [ITU-T L.1500]: Climate change refers to any change in climate over time, whether due to natural variability or as a result of human activity. The Intergovernmental Panel on Climate Change (IPCC) uses a relatively broad definition, referring to a change in the state of the climate that can be identified (e.g., using statistical tests) by changes in the mean and/or the variability of its properties, and that persists for an extended period, typically decades or longer. Climate change may be due to natural internal processes or external forces, or to persistent anthropogenic changes in the composition of the atmosphere or in land use.
+
+The IPCC makes a distinction between climate change that is directly attributable to human activities, and climate variability that is attributable to natural causes. For the purposes of this report, either definition may be suitable depending on the context of the analysis.
+
+**3.1.2 climate change adaptation** [ITU-T L.1500]: Adaptation to climate change can be defined as the adjustment in ecological, social or economic systems in response to actual or expected climatic stimuli and their effects. It refers to changes in processes, practices and structures to moderate potential harm or benefit from opportunities associated with climate change.
+
+**3.1.3 food security** [b-WHO 2001]: Food security is a situation that exists when all people, at all times, have physical, social and economic access to sufficient, safe and nutritious food that meets their dietary needs and food preferences for an active and healthy life.
+
+**3.1.4 vulnerability to climate change** [b-IPCC]: Degree to which a system is susceptible to injury, damage, or harm (one part – the problematic or detrimental part – of sensitivity).
+
+**3.1.5 climate variability** [b-WMO]: Variations in the mean state and other statistics of the climate on all temporal and spatial scales, beyond individual weather events.
+
+NOTE – Variability is the range of climate compared to its average. The fluctuations comprising climate variability can influence patterns of rainfall, temperature and other variables on timescales anywhere from a few weeks to a few decades.
+
+**3.1.6 climate change mitigation** [b-UNEP]: Efforts to reduce or prevent emission of greenhouse gases.
+
+NOTE – Mitigation can mean using new technologies and renewable energies, making older equipment more energy efficient, or changing management practices or consumer behaviour.
+
+**3.1.7 aquaculture** [b-Indian University]: Farming fish and other aquatic organisms.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|------------------------------------------|
+| EWS | Early Warning System |
+| FFMA | The Fisher Friend Mobile Application |
+| FFP | The Fisher Friend Programme |
+| GHG | Greenhouse Gas |
+| GIS | Geographic Information Systems |
+| ICT | Information and Communication Technology |
+| PFZ | Potential Fishing Zone |
+
+## 5 Conventions
+
+None.
+
+## 6 Impacts of climate change on the fisheries sector
+
+### 6.1 Ecosystem impacts
+
+Climate change is having both physical and biological impact on ecosystems by modifying the distribution of marine and freshwater species. In general, warm-water species are being displaced towards the poles and are experiencing changes in the size and productivity of their habitats. In warmer parts of the world, ecosystem productivity is likely to be reduced in most tropical and subtropical oceans, seas and lakes and increased in high latitudes. Increased temperatures will also affect the physiological processes of fish, resulting in both positive and negative effects on fisheries and aquaculture systems depending on the region and latitude.
+
+Climate change is already affecting the seasonality of particular biological processes, altering marine and freshwater food webs with unpredictable consequences for fish production. Increased risks of species invasions and the spreading of vector-borne diseases are additional concerns. Differential warming between land and oceans and between polar and tropical regions will affect the intensity, frequency and seasonality of climate patterns (e.g., El Niño) and extreme weather events (e.g., floods, droughts and storms).
+
+These events will impact the stability of related marine and freshwater resources. Sea level rises, glacier melting, ocean acidification and changes in precipitation, groundwater and river flows will significantly affect coral reefs, wetlands, rivers, lakes and estuaries such as Chesapeake Bay in
+
+Maryland. The bays surrounding the boroughs of New York City are also estuaries. San Francisco Bay in California and Lake Pontchartrain in Louisiana are other examples of large, developed estuaries requiring adaptive measures to exploit opportunities and minimize impacts on fisheries and aquaculture systems.
+
+### 6.2 Impacts on livelihoods
+
+Changes in distribution, the composition of species and habitats will require changes in fishing practices and aquaculture operations, as well as in the location of landing, farming and processing facilities.
+
+Extreme events will also have an impact on the infrastructure, ranging from landing and farming sites to post-harvest facilities and transport routes. They will also affect safety at sea and settlements, with communities living in low-lying areas at particular risk. Water stress and competition for water resources will affect aquaculture operations and inland fisheries production and are likely to increase conflicts among water dependent activities.
+
+Livelihood strategies will have to be modified, for example, with changes in fishers' migration patterns due to changes in the timing of fishing activities. Reduced livelihood options inside and outside the fisheries sector will force occupational changes and may increase social pressures. Livelihood diversification is an established means of risk transfer and reduction in the face of shocks, but reduced options for diversification will negatively affect the outcomes of livelihoods.
+
+There are particular gender dimensions, including competition for resource access, risk from extreme events and occupational changes in areas such as markets, distribution and processing, in which women currently play a significant role. The implications of climate change affect the four dimensions of food security as follows:
+
+- the availability of aquatic foods will vary through changes in habitats, stocks and species distribution;
+- the stability of supply will be impacted by changes in seasonality, increased variance in ecosystem productivity and increased supply variability and risks;
+- the access to aquatic foods will be affected by changes in livelihoods and catching or farming opportunities; and
+- the utilization of aquatic products will also be impacted, for example, some societies and communities will need to adjust to species not traditionally consumed [b-FAO, 2009].
+
+### 6.3 Economic impact on people
+
+Countries in Central and Western Africa (e.g., Malawi, Guinea, Senegal and Uganda), North-Western South-America (Peru and Colombia) and four tropical Asian countries (Bangladesh, Cambodia, Pakistan, and Yemen) were identified as most vulnerable. This vulnerability is due to the combined effect of predicted warming, the relative importance of fisheries to national economies and diets and limited societal capacity to adapt to potential impacts and opportunities. Many vulnerable countries are also among the world's least developed countries whose inhabitants are among the world's poorest and who are twice as reliant on fish, which provides 27 per cent of dietary protein compared to 13 per cent in less vulnerable countries. These countries also produce 20 per cent of the world's fish exports and are in the greatest need of adaptation planning to maintain or enhance the contribution that fisheries can make to poverty reduction. [b-Wiley]
+
+## 7 Climate change adaptation measures for the fisheries sector
+
+Table 1, adapted from [b-FAO, 2014], shows climate change adaptation measures for the fisheries sector.
+
+**Table 1 – Climate change adaptation measures for the fisheries sector**
+
+| Impact | Adaptation measure |
+|-----------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Reduced yields | • Access higher-value markets • Increase fishing effort (risks overexploitation) • Shift aquaculture to non-carnivorous commodities • Selective breeding for increased resilience in aquaculture Moving/planning siting of cage aquaculture facilities • Change aquaculture feed management: fishmeal and fish oil replacement; find more • Appropriate feeds • Migration as fish distribution changes (risks overexploitation) • Research and investments into predicting where fish populations will move to (risks overexploitation) • Improve water-use efficiency and sharing efficacy (e.g., with rice paddy irrigators) in aquaculture • Aquaculture infrastructure investments (e.g., nylon netting and raised dykes in flood-prone pond systems) |
+| Increased yield variability | • Diversify livelihood portfolio (e.g., algae cultivation for bio fuels or engage in non-fishery economic activity such as ecotourism) • Precautionary management • Ecosystem approach to fisheries/aquaculture and adaptive management • Shift to culture-based fisheries • Shift to propagated seed for previously wild-caught seed stocks (higher cost) |
+| Reduced profitability | • Diversify livelihoods, markets and/or products • Exit fishery • Reduce costs to increase efficiency • Change aquaculture feed management • Shift to culture-based fisheries |
+| Increased risk | • Adjustments in insurance markets • Insurance underwriting • Weather warning systems • Improved communication networks • Workshops to teach data gathering and interpretation • Monitoring of harmful algal blooms where molluscs farmed • Improved vessel stability/safety • Compensation for impacts |
+| Increased vulnerability for those living near rivers and coasts | • Hard defences (e.g., sea walls) (risks affecting local ecosystem processes and/or local livelihoods) • Soft defences (e.g., wetland rehabilitation or managed retreat) (risks affecting local livelihoods) • Early warning systems and education • Rehabilitation and disaster response • Infrastructure provision (e.g., harbour and landing site protection, building aquaculture facilities to withstand increased storm damage) • Post-disaster recovery • Encourage native aquaculture species to reduce impacts if fish escape damaged facility |
+
+## **8 The eco-system of the fisheries sector to be involved in adaptation**
+
+The eco-system of the fisheries sector has many stakeholders: e.g., fishermen, fisheries communities, scientists, policy makers, extension officers, private sectors, non-profit organizations, laboratories, field-workers, market research institutes, management professionals, input suppliers, technical experts, self-help groups, government, etc.
+
+Constraints in information and knowledge transfer may include content appropriateness, literacy, digital literacy, skill sets, digital scepticism, age-related, etc. Content appropriateness may also depend upon whether information is intended for the wider area or for the local level. The format in which it is delivered and livelihood priorities may also impact content appropriateness. There may be a requirement for forecasting, modelling and making projections. Adaptation and mitigation strategies may also require information concerning fisheries practices, resources and processes, as well as output processes.
+
+In the context of fisheries, often characterized by poverty, remoteness and marginalization, ICTs can enable new responses to the challenges posed by more frequent and intense climatic events. ICTs can become a strategic enabler of action to create awareness to mitigate, monitor and adapt to climate change within fisheries. ICTs can also help in the adoption of innovative strategies based on emerging and traditional knowledge and information tools.
+
+## **9 Trends in ICTs which are relevant to the fisheries sector**
+
+Recent increases in ICT affordability, accessibility and adaptability have resulted in their use even within rural homesteads relying on fisheries. Many of the information needs that could improve smallholder livelihoods can be fulfilled with the effective and easy use of ICTs, facilitated by the proliferation of innovations including small devices such as mobile or smart phones and infrastructure such as cloud computing facilities.
+
+The following trends have been the key drivers of the use of ICTs in the fisheries sector, particularly for fishermen or producers:
+
+- Low-cost and pervasive ICT connectivity;
+- Adaptable and more affordable tools;
+- Innovative business models and partnerships;
+- The democratization of information, including the open access movement and social media;
+- Access to information relevant to fisheries weather forecasts, marketing information, etc.
+
+## **10 ICT components which are relevant to the fisheries sector**
+
+The following are frequently used ICT components in the agricultural sector that can also be applied to the fisheries sector:
+
+- ICT systems: Data storage, computational resources.
+- ICT network: Communication networks, fixed line networks, mobile networks and satellite networks for data acquisition and knowledge dissemination.
+- ICT media types: Audio, video, text, image.
+- ICT applications: Data analytic models, expert systems, forecasting models, early warning systems.
+- ICT tools: Blogs, discussion forums, RSS feeds, social networking, spatial geo-tagging tools, online training, crowd sourcing, mobile Apps.
+- ICT end-user devices/access points: Mobile feature phones, mobile smart phones, PCs, community Internet access points, e.g., touch kiosks.
+- IoT devices: Wireless sensor networks, smart phones, etc.
+
+- ICT device features: Personal information management tools, e.g., calendar, reminder, etc.
+
+## **11 How can ICTs help sustain the fisheries sector in the events of climate change**
+
+### **11.1 ICT to monitor site condition**
+
+Among the various ICT possibilities, geographic information systems (GIS) represent a key tool for decision support for fishermen to make informed decisions about their own personal safety and the safety of their boats, as well as to make smart choices for fishing and marketing their catch.
+
+GIS provides fishermen with immediate access to critical, near real-time knowledge and information services on weather, potential fishing zones, ocean state forecasts and market related information [b-FFMA]. Examples of how monitoring site conditions using ICTs can help sustain the fisheries sector are given in Appendices I to IV.
+
+### **11.2 ICTs to promote knowledge sharing and improve management**
+
+Internet and community radio can be used to create awareness and provide access to content on fisheries codes (e.g., code of conduct for responsible fisheries) and regulations, as well as information on aquaculture management in different climatic conditions (e.g., feeding practices, selection of stock, etc.). Also, scientific information on water parameters in tanks, feed supply, shrimp growth, for example, and atmospheric conditions can be provided to aqua farmers through ICTs [b-NICCD]. Examples of how knowledge sharing using ICTs can help sustain the fisheries sector are given in Appendix III.
+
+### **11.3 ICTs to predict weather and types of fish-catches**
+
+ICTs are increasingly being used to ensure safety at sea. Fishermen can have access to up-to-date weather information through community radio stations, loudspeakers and tele centres collecting and broadcasting information before setting out. Mobiles and radios also allow better communication with other boats and the shore [b-FAO].
+
+In addition, improvements in the design of fishing equipment through the implementation of ICTs can increase the selectivity of the gear with the aim of catching only the preferred size and the right quality of the target species (selective catch). ICTs can help with the design of the equipment as well as its day-to-day operations [b-NORDEN, 2009]. Examples of how ICTs are used to predict weather and types of fish-catches are given in Appendix II.
+
+### **11.4 ICTs for forecasting**
+
+Extensive weather station networks are needed for monitoring key climate parameters such as wind speed, precipitation, barometric pressure, soil moisture, wind direction, air temperature and relative humidity. These parameters may be used both for forecasting and for decadal climate modelling. The technologies needed include weather satellites and both local and remote automated weather stations. Similar to telecommunications networks, in general, there are logistical and financial problems to be overcome in order to achieve sufficient global coverage to collect the required data.
+
+Satellite observations include visible spectrum cameras to detect storms and deforestation; infrared cameras to detect cloud cover and surface temperatures and sea level rises; particle detectors of solar emissions [b-WRI]. Examples of ICTs used for forecasting are given in Appendices I, II and IV.
+
+### **11.5 ICTs for leveraging market realities**
+
+Good and timely knowledge is essential for competing in local and global markets. Information about prices and availability can be shared across value chains, increasing the power of smaller or otherwise disadvantaged groups while reducing the volatility of fish prices and wastage of fish.
+
+Key ICTs are:
+
+- Community or loudspeaker radio: price information received by a radio station or researched via specialist websites at a local telecentre is passed on to the community through established communication channels; and
+- Mobile phones: provided there is network coverage, fishermen, buyers and traders communicate through voice calls, via SMS messages or by accessing specialist WAP services; the catch can be sold while still out at sea; buyers and processors can be informed of catch details before landing [b-FAO]. Examples of how ICTs are used for leveraging market realities are given in Appendices I and II.
+
+### 11.6 ICTs for emergency/alert systems
+
+ICTs can be used as warning systems to involve seismic and wave sensors, satellite links and relay centres that trigger sirens and radio and other alerts. At the local level, ICT equipment can be distributed together with boats and nets. Fishermen can then chart and report locations more securely using GPS and can communicate more easily to avert risks [b-FAO]. Examples of how ICTs are used for emergencies/alert systems are given in Appendix II.
+
+### 11.7 ICTs for maritime boundaries
+
+Fishermen can be warned by an alert when approaching within a few kilometres of international territorial waters. ICTs can be used to alert fishermen to steer clear from illegal entry of territorial waters or occupational hazards such as military training zones or submerged reefs, etc. In this way ICTs act to safeguard fishermen from potential international conflicts and distress at sea [b-FFMA]. Examples of how ICTs are used for maritime boundaries are given in Appendix II.
+
+### 11.8 ICTs for efficient decision-making (example from Lake Victoria)
+
+ICTs can enable access to user-friendly (e.g., using local languages, images and sound) regulatory content (e.g., policies, rights and obligations) that can help to inform decision making and management approaches, having an impact on fisheries productivity and sustainability.
+
+ICTs can support institutions in the process of assessing available information (e.g., regarding vulnerability, climatic impacts, adaptive practices, etc.) in order to inform decision-making processes. Tools such as Internet-based platforms, mobile phones, radio and e-mail can enable open consultation processes to assess vulnerabilities, identify priorities and adaptation practices and systematize information gathered at the local level. ICT-enabled models and projections can help institutions to identify and assess current and future climatic risks [b-NICCD]. Examples of how ICTs are used for efficient decision-making are given in Appendix IV.
+
+### 11.9 Technology for high-accuracy fuel efficiency estimation
+
+The development of technology that uses analysis of ship-related big data to estimate fuel efficiency, speed and other performance in actual sea conditions, to a highly accurate margin of error of less than 5 per cent has been recently announced.
+
+This newly developed technology utilizes a massive volume of measurement data gathered while the ship is underway, including sensor data of meteorological and hydrographic conditions such as wind, waves, and ocean currents, ship engine log data and data about the speed and position of the ship. By applying the results of this research, it was demonstrated that it could improve fuel efficiency by about 5 per cent when compared to previous results, with ships that navigate the shortest shipping routes.
+
+With this technology, it is possible to accurately estimate a ship's performance in actual sea conditions, which previously had a large margin of error. The technology enables the evaluation of ship performance, design feedback, and significant improvements in fuel efficiency when used in ship navigation.
+
+Examples of how the technology is used for high-accuracy fuel efficiency estimation through a ship's operational data is given in Appendix V.
+
+Table 2 shows ICT tools, functions and benefits for fishermen [b-African Journal].
+
+**Table 2**
+
+| ICT tools | Functions/benefits |
+|--------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| GPS | Marking the areas of the fish location, GPS can assist fishermen to return to exactly the right place night or day. GPS provides information such as latitude, longitude, altitude, surface speed, sunrise and sunset times, odometer and accuracy warning system. |
+| Sonar | Using sonar, fishermen can immediately get a complete, up to date, available map of the whole fishing area showing the exact location, extent, density, depth, movement, species and size of all fish shoals. In addition, information regarding sea bottom such as depth, contours, slopes and composition (rocky, sandy, muddy, etc.) can easily be attained. |
+| Wireless set (VHF radio) | Radio (VHF) enhances security aspects for fishermen. If anything happens to them at sea they can communicate with other vessels and the responsible agencies so that immediate action can be taken. In addition, they can immediately share information regarding the fishing spots with the others. Moreover, using radio they can negotiate a better price with the dealer even when they are still at sea. |
+| Computer | For record purposes (example: profit and loss, species caught, weather condition, markets, etc.). |
+| Internet | Internet can be used to search for, disseminate and share fisheries related information such as market prices, online applications, weather conditions, professional advice, loan services, business opportunities, etc. among/between colleagues and related agencies. |
+| Mobile phone | Mobile phones can be used to search for, disseminate and share fisheries related information such as market prices, online applications, weather conditions, professional advice, loan services, business opportunities, etc., among/between colleagues and related agencies. Moreover, using mobile phones they can negotiate a better price with the dealer even when they are still at sea. |
+
+## Appendix I
+
+## SayadTec application to adapt to climate change effects in the fisheries sector
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### I.1 Introduction
+
+For some countries and communities, the percentage of aquatic foods account for up to 50 per cent of animal protein in some small island states. The sector employs 43.5 million people, many of these in developing countries and the processing, marketing, distribution and supply industries associated with fishing and aquaculture employ up to another 200 million people [b-FAO, 2014].
+
+Climate change will affect fisheries and aquaculture in ways such as acidification, changes in sea temperatures and circulation patterns, the frequency and severity of extreme events and sea-level rises and associated ecological changes. Both direct and indirect impacts include impacts on targeted populations' range and productivity, habitats and food webs as well as impacts on fisheries and aquaculture costs and productivity and livelihoods and safety of fishing communities.
+
+Approaching climate change typically involves actions that either reduce the amount of carbon dioxide and other greenhouse gases (GHGs) in the atmosphere or that prepare society for the impacts associated with climate change via adaptation. Adaptation can be planned or it can be autonomous (i.e., spontaneous reaction to environmental change or planned action based on climate-induced changes). Autonomous adaptation in fisheries may include changing the timing or locations of fishing as species arrive early/late or shift to new areas. Planned adaptation in fisheries may include research funding for finding species resistant to salinity and temperature fluctuations for aquaculture.
+
+Adaptation in fisheries and aquaculture can include a variety of policy and governance actions, specific technical support or community capacity building activities that address multiple sectors rather than just capture fisheries or aquaculture farmers. ICTs play a major role in adaptation in fisheries, including sonar applications for locating fish, global positioning systems (GPS) for navigation and location finding, radio programming with fishing communities, Web-based information and networking resources, etc.
+
+In response to these impacts and in order to help the fisheries sector in Egypt to adapt to climate change impacts, The Egyptian National Authority for Remote Sensing & Space Sciences (NARSS), and the General Authority for Fish Resources Development (GAFRD), in cooperation with the information technology institute developed the SayadTec application to adapt to climate change effects in the fisheries sector.
+
+### I.2 SayadTec system description
+
+SayadTec is intended to help fishermen in the Gulf of Suez to gain pre-fishing knowledge in order to increase their productivity, efficiency and income using ICTs services.
+
+SayadTec aims to provide the following information:
+
+- Finding fishing hot spots obtained through analysis on real time satellite images with coordinates (longitude and latitude).
+- Detecting current location and informing fishermen of the nearest fishing spot and weather conditions on a daily basis utilizing GPS.
+- Service broadcasting that warns fishermen about any sudden changes in weather.
+
+The system has two interfaces: a website interface and a mobile interface.
+
+### I.3 SayadTec system modules
+
+As shown in Figure I.1, the SayadTec system has seven modules; these modules are briefly described in clauses I.3.1 to I.3.7.
+
+
+
+The diagram illustrates the system modules of the SayadTec application. At the center is a blue rectangular box labeled "System modules that is implemented by website and mobile application". Seven red arrows point outwards from this central box to seven surrounding blue oval shapes, each representing a different module. The modules are: "Potential fishing zone map for fishermen" (top-left), "Mobile application implementing web functionalities for fishers and traders" (top-right), "SMS service to support fishers with no smart phones" (middle-left), "Administrator control panel" (middle-right), "Weather forecasting service" (bottom-left), "Market module for traders" (bottom-center), and "User profiles for fishers and traders" (bottom-right). The entire diagram is enclosed in a dark blue header bar labeled "System modules". A small text "L.1505(18)\_FI.1" is visible at the bottom right of the diagram.
+
+Diagram of System modules showing a central module connected to seven peripheral modules.
+
+**Figure I.1 – System modules of the SayadTec application**
+
+#### I.3.1 SayadTec website services
+
+The SayadTec website provides maps that present fishing spots along the Egyptian coastline with coordinates (longitude and latitude), see Figure I.2.
+
+
+
+The figure is a screenshot of a map interface, likely Google Maps, showing a coastal area near Suez, Egypt. Two red location pins are placed on the map, indicating fishing spots. A white information box above the pins displays the coordinates: "lat:29.997741386 lon:32.584119882 X". The map includes standard interface elements like zoom controls, a street view icon, and a copyright notice at the bottom right: "Map data ©2014 Google, ORION-ME Terms of Use".
+
+Screenshot of a map showing fishing spots near Suez with coordinates.
+
+**Figure I.2 – Example of fishing spots mapping**
+
+#### I.3.2 SayadTec SMS service
+
+SayadTec includes a daily SMS service to provide information to a wide range of fishermen (including those who do not possess smart phones). An example of a SayadTec SMS is shown in Figure I.3.
+
+
+
+A screenshot of an iPhone's Messages app. The top status bar shows 'etisalat' as the carrier, the time as '9:57 PM', and a battery level of '61%'. The Messages app is open to a conversation with 'SayadTec'. At the top, there are 'Messages', 'SayadTec', and 'Edit' buttons. Below the name are 'Call' and 'Add to Contacts' buttons. A text message bubble contains the coordinates 'lon: 32.54447962040' and 'lat: 29.49109377450'. The message is timestamped '2014-06-15 8:33 PM'. At the bottom, there is a text input field with the placeholder 'Text Message' and a green 'Send' button.
+
+**Figure I.3 – Snapshot of SMS services provided by SayadTec**
+
+#### **I.3.3 SayadTec weather forecast service**
+
+SayadTec provides a ten day weather forecast according to the current detected location, see Figure I.4.
+
+
+
+A screenshot of a weather forecast display. At the top, there is a small sun icon with three dots above it. Below the icon is a horizontal bar containing weather information in Arabic. The bar is divided into several segments: 'حالة الجو: سماء صافية' (Weather: Clear sky), 'درجة الحرارة: 20.33' (Temperature: 20.33), 'الوقت: 15:25:3 Jun 2014' (Time: 15:25:3 Jun 2014), 'السحب: 0%' (Clouds: 0%), 'الضغط الجوي: 1017' (Air Pressure: 1017), 'نسبة الرطوبة: 79%' (Humidity: 79%), and 'جافا 49 درجة' (Java 49 degrees).
+
+**Figure I.4 – Sample of weather forecast by SayadTec**
+
+#### **I.3.4 SayadTec market module for traders**
+
+SayadTec proposes an interactive interface between fishermen and traders, see Figure I.5.
+
+أنواع الأسماك بوري ▼
+
+| | ادخل كمية الشراء | التاريخ | الكمية بالكيلو جرام | المدينه | الاسم الصياد |
+|------|------------------|---------------------|---------------------|----------|--------------|
+| شراء | | 20/07/35 02:42:08 م | 6 | بور سعيد | بيتسوي ماجد |
+| شراء | | 20/07/35 02:45:54 م | 654 | بور سعيد | بيتسوي ماجد |
+| شراء | | 20/07/35 02:55:27 م | 100 | بور سعيد | بيتسوي ماجد |
+| شراء | | 20/07/35 02:57:11 م | 1179 | بور سعيد | بيتسوي ماجد |
+| شراء | | 20/07/35 02:58:33 م | 322 | بور سعيد | بيتسوي ماجد |
+| شراء | | 06/11/35 12:00:00 ص | 300 | السويس | رجب السيد |
+
+**Figure I.5 – The interactive interface between fishermen and traders in Arabic**
+
+#### I.3.5 SayadTec user profile for fishermen and traders
+
+SayadTec provide a user profile for fishermen and traders that contains data on:
+
+- fishermen's catches;
+- data of suspended deals to be accepted or rejected; and
+- data on trading history.
+
+Examples (web and mobile views) of the SayadTec application for user profiles for fishermen and traders are shown in Figure I.6.
+
+##### بيانات الصيد
+
+اضافة بوري ▼ إضافة كمية:
+
+نوع السمك المراد عرضه بوري ▼
+
+| مسح البيانات | تاريخ الصيد | كمية الصيد |
+|--------------|---------------------|------------|
+| مسح | 20/07/35 02:42:08 م | 6 |
+| مسح | 20/07/35 02:45:54 م | 654 |
+| مسح | 20/07/35 02:55:27 م | 100 |
+| مسح | 20/07/35 02:57:11 م | 1179 |
+
+|< << Page 1 of 2 >> |>
+
+ملفى
+كمية السمك
+
+التاريخ
+
+boorey ▼
+
+النوع
+
+الكمية
+
+| الاسم الأول | اسم العائلة | الكمية بالكيلو جرام | نوع السمك | حالة الصفقة |
+|-------------|-------------|---------------------|-----------|-------------|
+| يحيى | السيد | 332 | بورى | غير محدد |
+
+|< << Page 1 of 1 >> >|
+
+| الاسم الأول | اسم العائلة | الكمية بالكيلو جرام | نوع السمك | حالة الصفقة |
+|-------------|-------------|---------------------|-----------|-------------|
+| يحيى | السيد | 100 | بورى | تم الرفض |
+| رجب | السيد | 800 | سردين | تم الالغاء |
+| بيسوي | ماجد | 44 | بورى | تم الالغاء |
+| بيسوي | ماجد | 44 | بورى | تم الالغاء |
+
+|< << Page 1 of 5 >> >|
+
+**Figure I.6 – User profiles for fishermen and traders (web and mobile view) in Arabic**
+
+#### I.3.6 SayadTec administrative control panel
+
+SayadTec uploads Excel sheets that contain satellite and geographic data broadcasts and emergency SMSs to all subscribers.
+
+#### I.3.7 SayadTec mobile application implementing web functionalities
+
+SayadTec uses GPS to inform users of their current location and to indicate the nearest fishing spot and local weather conditions on a daily basis.
+
+### I.4 Technologies and tools
+
+As SayadTec is a Net project, Microsoft products are mainly used, namely:
+
+- Visual studio 2013;
+- SQL server 2012;
+- Windows Azure; and
+- Titanium.
+
+### I.5 Future SayadTec developments
+
+The following are the intentions of some future developments of SayadTec:
+
+- Widen the covered area from the Gulf of Suez to the entire Red Sea and then the Mediterranean;
+- Include freshwater zone in addition to seawater zones;
+- Add the ability to detect fish types available in each spot;
+- Extend market functionality to simulate a real world scenario; and
+- Include reviews for fishing spots.
+
+1 Figures are intended to illustrate through snapshots how information is provided to fishermen in their local languages.
+
+## **Appendix II**
+
+## **Fisher friend mobile application (FFMA) A mobile application using ICTs to adapt to climate change effects in the fisheries sector**
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### **II.1 Introduction**
+
+Fishing communities are among the poorest, most vulnerable and isolated communities of India. Their social exclusion due to geographical separation and cultural isolation contributes to poverty. The fishermen and women witness declining trends of livelihood security, increasing poverty and vulnerability leading to competition between various fishing systems, over exploitation and depletion of marine resources. Climate change and the rapid pace of development have put these vulnerable communities at high risk. Fishermen's lives are precarious, largely dependent on knowledge of the sea, weather and the markets for their lives and livelihoods.
+
+The Fisher Friend Programme (FFP) developed by the M. S. Swaminathan Research Foundation (MSSRF) since 2009, helps as a robust, holistic intervention by protecting fishermen's lives and fishing assets from occupational hazards and by increasing the empowerment of their livelihoods. The programme underscores a shore-to-shore approach by acting as a fisherman's credible and accessible decision-making support system through every step of his daily fishing experience.
+
+The FFP covers marginalized coastal communities in Tamil Nadu, Puducherry, Andhra Pradesh, Kerala and Odisha and operates in the English, Tamil, Telugu, Malayalam and Odiya languages. The entire southeast coastline was selected due to the diversity of needs, risks, vulnerability, disaster proneness and destruction of biodiversity.
+
+### **II.2 FFMA system description**
+
+The fisher friend mobile application (FFMA) is a unique, single window solution for the holistic shore-to-shore needs of fishing communities, providing vulnerable fishermen with immediate access to critical, near real-time knowledge and information services on weather, potential fishing zones, ocean state forecasts and market related information.
+
+The application is an efficient and effective decision support tool for actors in the fishing community to make informed decisions about their own personal safety and the safety of their boats, as well as smart choices relating to the fishing and marketing of their catch.
+
+FFMA was developed on an android platform in partnership with Wireless Reach Qualcomm and Tata Consultancy Services and is currently available in English, Tamil, and Telugu.
+
+### **II.3 FFMA system features**
+
+Clauses II.3.1 to II.3.9 briefly describe features of the FFMA application.
+
+#### II.3.1 Potential fishing zones (PFZ)
+
+
+
+A hand holding a black smartphone. The screen displays a map of a coastal area with various colored lines and markers. At the top of the screen, there is a text box showing "Coordinates: 24.5135, 88.3543". Below the map, there are several buttons and icons. The background of the image is a blue and green abstract pattern.
+
+A hand holding a smartphone displaying a map with GPS coordinates and fishing zone information.
+
+**Figure II.1 – GPS coordinates received on mobile**
+
+Using the potential fishing zones (PFZ) feature, fishermen receive GPS coordinates, as shown in Figure II.1, of large shoal concentrations through the PFZ advisories. Fishermen also receive in-season, species-specific advisories for high value fish which enable them to increase their incomes. PFZ helps fishermen to make informed decisions thereby minimizing expenditure of time, energy and fuel and boosts the fishermen's confidence of a good catch, even before setting out to sea.
+
+#### II.3.2 Ocean state and weather forecast
+
+
+
+Three mobile phones are shown side-by-side. The phone on the left is red and displays a screen with text and icons. The phone in the middle is black and displays a screen with a table of data. The phone on the right is black and displays a screen with a list of items. The background is dark.
+
+Three mobile phones displaying ocean and weather forecast information.
+
+**Figure II.2 – Ocean and weather forecast feature on mobiles**
+
+The ocean state and weather forecast feature, as shown in Figure II.2, helps fishermen plan and control their fishing experience by protecting their lives and assets. When there are adverse weather conditions forecast, they stay ashore and their time can be gainfully employed in mending nets, avoiding possible threats to life and wasteful expenditures of fishing materials.
+
+#### II.3.3 Global positioning system (GPS)
+
+The GPS application, whether as a standalone device or as an application on a mobile phone or laptop computer, is an indispensable tool that assists fishermen in tracking the PFZ, reducing loitering time and fuel expenditure and recording navigation history. GPS also helps track sea routes and so helps fishermen return to shore safely, especially during turbulent and low visibility weather.
+
+#### II.3.4 Danger zone alerts
+
+FFMA crowd sources information from other sailors about marine hazards and makes this information available to fishermen to safeguard their lives and assets by providing warning of submerged dangers such as sunken ships, coral reefs, etc.
+
+#### II.3.5 Disaster alerts
+
+FFMA provides life-saving and timely disaster alerts about impending cyclones, tsunamis, etc. This information helps to protect fishermen and their assets.
+
+#### **II.3.6 Market realities information**
+
+Timely information about prevailing prices in landing centres aids fishermen in increasing their negotiating power and in leveraging market realities for their economic benefit.
+
+#### **II.3.7 Emergency contact numbers**
+
+Fishermen have immediate access to emergency contact numbers in case of maritime danger requiring immediate assistance.
+
+#### **II.3.8 International maritime border line (IBL)**
+
+Fishermen are warned by an alert when they arrive within 5 kilometres of an international territorial waters boundary. FFMA warns fishermen to steer clear of illegal occupational hazards and safeguards them from international conflict and distress. The Indian National Centre for Ocean Information Services (INCOIS) provides the scientific data while the Indian Coast Guard provides the IBL coordinates.
+
+#### **II.3.9 Other services**
+
+Other services such as news alerts, information on government schemes and subsidies, training programmes, latest information on technological innovations, etc. are provided to the fishermen on a regular basis, allowing them access to a range of knowledge services.
+
+### **II.4 Impact of FFMA summary**
+
+The following gives a summary of the impact of FFMA:
+
+- Increased life safety and asset security
+- Timely and informed decision-making
+- Shore-to-shore risk reduction
+- Increased fishing efficiency
+- Increased efficiency in fishing and quantity of catch
+- Increased bargaining power
+- Personalized user experience through archived navigational history
+
+### II.5 Awards
+
+
+
+The image is a composite of three photographs. The top photograph shows a group of five people on a stage during an award ceremony. A man in a white shirt is presenting a trophy to a woman in a red dress. Other people are standing nearby, and a large screen in the background displays the event's branding. The bottom-left photograph shows a 'Certificate of Recognition' for the 'Fisher Friend Mobile Application' from the mBillionth South Asia Awards 2014. It features an image of a black mobile phone. The bottom-right photograph shows a clear acrylic award trophy. It has a SIM card graphic at the top, followed by the text 'mBillionth 2014', 'm-Agriculture & Ecology', 'WINNER', and the website 'www.mbillionth.in'. The DEF logo is at the bottom.
+
+A composite image showing the award ceremony and the award itself. The top part shows a group of people on a stage receiving an award. The bottom left shows two 'Certificate of Recognition' documents for the Fisher Friend Mobile Application. The bottom right shows a clear acrylic award trophy with a SIM card graphic and the text 'mBillionth 2014 WINNER'.
+
+**Figure II.3 – Snapshots from the award ceremony for the FFMA**
+
+Fisher Friend Mobile Application of MSSRF won the mBillionth Award South Asia 2014 competing against 300 entries from nine South Asian countries under the category of m-Agriculture and Ecology, on 18 July 2014, at the India Habitat Centre, Delhi. mBillionth South Asia Awards is an initiative of the Digital Empowerment Foundation. The Digital Empowerment Foundation is a dedicated platform to recognize innovators who are socially empowering the lives of people through the use of ICTs and digital media tools. Jury comments: "It is remarkable to see the continued use of the fisher friend mobile application (FFMA), an application that supports one of the most vulnerable communities in India that earns its livelihood by venturing into the rough sea each day. The application has been used as a model by other countries such as Sri Lanka because of its positive impact."
+
+## **Appendix III**
+
+## **mKRISHI fisheries**
+
+### **A mobile application using ICTs to adapt to climate change effects in the fisheries sector**
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### **III.1 Introduction to the mKRISHI Fisheries application**
+
+Fishing is the main occupation of the coastal population of India, stretching over 8,000 kilometres of coastline. Most of the fishermen still use traditional knowledge to catch fish. This is more or less a trial and error approach which leads to uncertainty in the catch and possibly heavy diesel consumption. About 1.2 per cent of global oil consumption is used in fisheries and it has been found that fishing is the main contributor to global warming in the fisheries industry. In the Indian coastal waters, sea surface temperature increased by 0.2 to 0.3 degrees Celsius between 1960 and 2005 and is projected to increase by a further 2 to 3.5 degrees Celsius by 2099. A decline in the fish catch and an increase in fuel rates are two major concerns for fishermen today. Due to a large and growing population and the low-lying coastline, the Raigad district of Maharashtra is considered vulnerable to the impacts of climate change. Though services such as potential fishing zone (PFZ) and wind advisory services are available, they do not reach the majority of the fishermen because the current dissemination of media through fax and electrically powered devices depends on an electricity network, which requires maintenance and skills to operate. The Raigad district, where this solution was implemented, is the most prone to electricity failure hence all the electronic devices regularly fail to operate. ICTs, specifically mobile phones and related applications have the potential to overcome these challenges and bridge the gap between rural fishermen and research institutes in the fisheries domain.
+
+The mKRISHI Fisheries service is an initiative to empower fisheries communities by providing vital information services such as PFZ and wind speed and direction indicator applications on fishermen's mobile phones. PFZ information addresses their livelihood (by indicating where the fish are located) whereas wind speed and direction indicator applications address their safety concerns. The Indian National Centre for Ocean Information Services (INCOIS) analyses satellite images and provides a four-day forecast on PFZ and wind speed and direction four times a day. Fishermen leverage this information in almost real time to optimize their operations.
+
+### III.2 mKRISHI system description
+
+
+
+A photograph of a presentation slide titled 'मत्स्यव्यवसायाशी निगडीत उपजिविकेची साधने' (Means of livelihood related to fisheries). The slide lists seven items: स्वयं सहायता संघ निर्मिती (Self-help group formation), एम.कृषि. फिशरीज सेवा (M.Krishi Fisheries services), चाकं असलेल्या शीतपेट्या (Cold storage with fans), सोलार फीश ड्रायर (Solar fish dryer), अँडव्हान्स पॅकेजिंग मशिनस् (Advanced packaging machines), थेट बाजाराशी संपर्क (Direct market contact), and अलंकारिक माशांची पैदास (Ornamental fish production). To the right of the text is a photograph of a mobile phone displaying the 'FISHERIES SERVICES' application, which features a fish logo and the text 'Mumbai' and 'mKRISHI'.
+
+**Figure III.1 – Information conveyed to fishermen**
+
+As shown in Figure III.1 by simply clicking a smart phone button, the mobile application will alert aquaculture farmers to cloud formation, rainfall and temperature forecasts, and in addition will provide guidance on measures to be taken to protect their stock.
+
+The project, which was launched under the Digital India Programme on an experimental basis in Gujarat, will be extended across the country in three months.
+
+Scientific information on water parameters in tanks, feed supply, shrimp growth and atmospheric conditions will be provided to aquaculture farmers by project experts.
+
+To date aquaculture farmers have kept manual records, which do not provide up-to-date information to the aquaculture farmers on the latest trends in aquaculture. The mKRISHI Fisheries system will quickly help aquaculture farmers to become more confident.
+
+The aquaculture farmer should have a smartphone with 2G, 3G or a Wi-Fi facility. Once details of his farm activity have been entered, the aquaculture farmer receives guidance from experts in graphical form. Do's and Don'ts and the best management practices will be provided in the form of texts, pictures and videos. The aquaculture farmer is also given information in the language of his choice.
+
+In addition a mobile application on global shrimp prices, which was launched by the Ministry of Commerce and Industry recently, helps farmers follow the prices of shrimp varieties such as *L. Vannamei* and *Black Tiger* in the international markets through SMS messages.
+
+Information on the latest international market trends is disseminated to aquaculture farmers through the Malaysia-based Infofish application. Helpfully the prices of shrimp varieties in Japan, Europe and US markets are sent to farmers in the form of the Indian Rupee currency.
+
+### III.3 Impact of the mKRISHI application
+
+
+
+**mKRISHI – MOBILE APPLICATION (DISSEMINATION)**
+
+The infographic illustrates the dissemination and impact of the mKRISHI application. On the top left, there are newspaper clippings from 'The Times of India' and 'Hello Raigad' with headlines like 'Mobiles mean more money for Raigad fishermen' and 'मत्स्य मोबाइल सेवा से मछुआरों को फायदा' (Benefit to fishermen from fishery mobile service). Below this, a yellow box lists key impacts:
+
+
+- Perceived as a large scale impact on fishing community safety, and livelihood.
+- Clear impact on the environment.
+- World bank found it effective & looking at scaling up.
+
+To the right, three mobile phone screens display the application's interface, including maps and data tables. A central diagram titled 'mKRISHI' shows 'Impact' at the center, surrounded by four categories:
+
+
+- Social:** Increase in Self-esteem, Safety (two major incidents highlighted)
+- Economic:** Upto 50% Cost saving (diesel, labor), Subsidy
+- Environmental:** Reduction in Diesel, Carbon Credit
+- Research:** Feedback based model innovation
+
+Implementation: CMFRI-RC, Mumbai and TCS
+
+INCIS
+
+Infographic showing the dissemination plan of the mKRISHI application. It includes newspaper clippings, mobile phone screens, and a central impact diagram.
+
+Figure III.2 – Dissemination plan of the mKRISHI application
+
+The mKRISHI service was initially deployed in 13 fishing communities in the Raigad district on Maharashtra for about a year with participation from the Indian Government's Central Marine Fisheries Research Institute (CMFRI), the World Bank and Tata Consultancy Services (TCS). An analysis of the pilot data found that the fishing yield had improved by 30-40 per cent. Diesel consumption, wherever applicable, was reduced by 30-50 per cent. This resulted in a potential positive environmental impact. Expansion of services is currently being continued in 56 communities in the Raigad district.
+
+## Appendix IV
+
+## Localized weather alert service for fishing villages on Lake Victoria
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The Uganda Department of Meteorology, the World Meteorological Organization (WMO), MTN, Ericsson, the National Lake Rescue Institute and the Kalangala fishing community have come together in a unique partnership combining mobile technology, weather forecasting and local know-how, to provide a localized weather alert service to fishing villages on Lake Victoria.
+
+### Mobile weather service
+
+Mobile weather service improves safety of fishermen in Uganda and provide the following:
+
+- Unique communications, meteorological and community partnership
+- Information technology protects lives and livelihoods
+
+WMO and Ericsson in partnership with MTN, Uganda Department of Meteorology and the National Lake Rescue Institute have made possible the delivery of daily weather forecasts and timely warnings in local languages. The service, still in its pilot phase, is being tested by over 1 000 fishermen in the Kalangala District of Lake Victoria. MTN, the Grameen Foundation AppLab Uganda and Ericsson together with the Uganda Department of Meteorology, are in the preparation stages of a wider service offer which will be made available for the entire Lake Victoria community in the next three months.
+
+MTN Uganda, in partnership with Uganda Department of Meteorology will, upon completion of the pilot project, deliver the mobile service free of charge to MTN customers. The unique weather information service will enable fishermen and traders to make informed decisions on, for example, when and where to fish in Lake Victoria, thus helping to save lives and preserve livelihoods.
+
+The pilot project involves training 19 fishing community representatives in a basic understanding of weather forecasts and how to respond to various alerts. Equipped with mobile phones, the community representatives then pass on their knowledge to fishermen and traders to sign up to the Mobile Weather Alert service. Thus far, the value of the Mobile Weather Alert forecast service is being repeatedly confirmed.
+
+According to Foundation AppLab Uganda, of 200 fishermen using the Mobile Weather Alert service 96 per cent of the respondents said it has improved the safety of their lives.
+
+Lake Victoria, the world's second-largest freshwater lake was chosen for the pilot project. Lake Victoria also provides a livelihood, directly and indirectly, to over 3.5 million people. The lake supports Africa's largest inland fishery and produces over 800 000 tons of fish annually, currently worth about USD 600 million and reported estimates indicate that as many as 5 000 members of the fishing community die in boating accidents in the lake each year because they are unprepared for bad weather conditions.
+
+Michael Nkalubo, Commissioner for the Uganda Department of Meteorology said: "This is a real demonstration of the importance of meteorological expertise to our society. It has also provided the Uganda Department of Meteorology with valuable feedback on the reliability of our forecasts for the very localized conditions on Lake Victoria. In future we hope to be able to extend the Mobile Weather Alert project to other fishing communities and to farmers and other community sectors as part of a wider effort to improve the reliability and reach of severe weather forecasting."
+
+MTN is excited about the pilot project and indeed this partnership, as it allows us to use mobile technology to further touch our communities in a way that brings about socio-economic change to their daily lives. We also believe that the pilot project holds great long-term benefits for the fishing community in the Lake Victoria region and the rest of the continent. Although it forms part of our
+
+corporate social investment, this initiative is integral to our continued efforts to find innovative mobile solutions that support the growth of agriculture and small-medium enterprises in emerging markets.
+
+Mary Power, Director of Resource Mobilization at WMO, said "Severe weather and climate events account for almost 90 per cent of natural disasters and related losses of life and property globally. Establishing and sustaining early warning systems (EWS) in places vulnerable to these events, such as Lake Victoria, where low incomes and marginal living conditions increase people's vulnerability, is critical. WMO works with National Meteorological Services to bring these essential services to the people to support economic development and better lifestyles."
+
+Working towards Ericsson's vision regarding a networked society in Africa is not just about building or expanding networks. It is about being able to address local issues as well as some of the world's biggest challenges, including security, climate change, sustainability and the availability of education and healthcare. These efforts are central to the transition to the networked society, a world where everything that can benefit from a connection will be connected enabling us to live and interact in new exciting and more sustainable ways.
+
+Tim de Wet, Founder of the National Lake Rescue Institute said: "Saving lives on water and protecting the marine environment is our core objective for marine communities utilizing the waterways of East Africa. The provision of the free Mobile Weather Alert has accorded marine communities the basic human right of 'choice'. They can now make an informed decision as to whether they travel, trade or fish on the Lake. The default value of this is that it reduces the risks for water users, lessening loss of life. This, therefore, has a direct impact on their economies with the resultant effect of poverty reduction."
+
+"In our work with small-holder farmers across Uganda, we have similarly found strong demand for timely and highly localized weather information. This solution, if properly contextualized, could be a powerful tool to also improve farm productivity and mitigate the risks of climate change through new products such as weather index-base crop insurance" said Sean Paavo Krepp the Grameen Foundation Country Director. Figure IV.1 shows scenes from Lake Victoria's fishing communities.
+
+
+
+A green wooden boat, labeled "PEOPLE'S WATER BUS" in white capital letters, is shown on a body of water. Several people are on board, some wearing life jackets. The boat is being rowed or poled through the water.
+
+A green wooden boat with 'PEOPLE'S WATER BUS' written on its side, carrying several people across a body of water.
+
+
+
+A man is sitting on a wooden boat, holding a young child. In the background, other people and boats are visible on the water, suggesting a busy fishing community.
+
+A man sitting on a wooden boat, holding a young child, with other people and boats visible in the background.
+
+**Figure IV.1 – Lake Victoria's fishing communities**
+
+## Appendix V
+
+## Analysis of ship-related big data to estimate fuel efficiency, speed and other performance factors
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Technological developments resulting from a joint research project between Fujitsu Laboratories Ltd. and Tokyo University of Marine Science and Technology enable highly precise estimates with a margin of error under 5 per cent and can also cut fuel consumption by 5 per cent.
+
+**Kawasaki, Japan, May 10, 2016**
+
+### V.1 Introduction
+
+Fujitsu Laboratories Ltd. announced the development of a technology that uses the analysis of ship-related big data to estimate fuel efficiency, speed and other performance related factors in actual sea conditions, to a highly accurate margin of error of less than 5 per cent.
+
+This newly developed technology uses Fujitsu Laboratories' proprietary high-dimensional statistical analysis technology to estimate the performance of ships actually at sea. The technology utilizes a massive volume of measurement data gathered while the ship is underway, including sensor data of meteorological and hydrographic conditions such as wind, waves, and ocean currents, ship engine log data and data about the speed and position of the ship.
+
+By applying the results of this research to the Tokyo University of Marine Science and Technology weather routing simulator for evaluation, Fujitsu Laboratories demonstrated it could improve fuel efficiency by about 5 per cent from previous results, with ships that navigate the shortest shipping routes.
+
+With this technology, it is possible to accurately estimate a ship's performance in actual sea conditions, which previously had a large margin of error, enabling the evaluation of ship performance, design feedback and significant improvements in fuel efficiency when used in ship navigation.
+
+This technology uses Fujitsu's AI technology, Human Centric AI Zinrai and Fujitsu Laboratories will continue to improve its estimation accuracy through further ongoing operational trials.
+
+The technology was exhibited at Fujitsu Forum 2016, held on May 19th and 20th at the Tokyo International Forum (Tokyo, Japan).
+
+### V.2 Background
+
+For the shipping industry, the impact of shipping on the environment and the economics and safety of navigation are huge issues. In 2012, the amount of CO2 emitted by seaborne shipping reached about 900 million tons, roughly 3 per cent of the world's total CO2 emissions. In line with revisions to a convention of the International Maritime Organization (IMO), which came into force in 2013, there are now restrictions on CO2 emissions for newly built ships.
+
+There are also cases in the maritime shipping industry where a company's annual fuel costs may exceed several hundred billion Yen, so there is also a need for reductions in fuel costs.
+
+### V.3 Issues
+
+If maritime operators have an accurate understanding of the effects of meteorological and hydrographic conditions on a ship's fuel performance, they can determine whether it is better, in terms of fuel efficiency, to take the shortest route, or to take a longer route to avoid the effects of adverse wind, waves and currents.
+
+Previously ship performance estimation technologies relied on experiments with model ships in water tanks, or on physics model simulations. These simulations could not take into account the complicated interactions of the wind, waves, and ocean currents and ship conditions. This problem led to large margins of error in predictions.
+
+### **V.4 About the new technology**
+
+Today, using Zinrai AI technology on big data from ships, Fujitsu Laboratories has developed a high-accuracy technology that estimates ship performance in actual sea conditions, with a margin of error less than 5 per cent. In addition, by collecting and analysing operational data from ships actually at sea, this technology is being put to use in designing safe and economical ships and in improving the navigation of ships at sea.
+
+This technology uses Fujitsu Laboratories' proprietary high-dimensional statistical analysis technology to analyse and learn from high-dimensional data that incorporates a variety of directly measured data from ships that are underway, including meteorological and hydrographical sensor data of wind, waves and ocean currents, as well as ship engine log data, ship speed and positional data. The technology then estimates the ship's performance under meteorological and hydrographical conditions for which there is no actual measurement data.
+
+The key features of the technology are outlined in clauses V.4.1 and V.4.2.
+
+#### **V.4.1 Analysis technology that uses actual-travel unprocessed data**
+
+Fujitsu Laboratories' proprietary high-dimensional statistical analysis technology allowed measurement data obtained from ships on the move to be used directly, for the successful analysis of the influence of a variety of simultaneously integrated factors, such as meteorological and hydrographic conditions. This enables performance estimates that incorporate the complex interaction of conditions, including wind, waves and ocean currents, not based on synthesized data from experiments in tanks of water, but on data gathered directly from actual ships at sea.
+
+#### **V.4.2 Technology that automatically groups measurement data and adjusts the degree of machine learning for each group**
+
+Previously with physics models, because physical phenomena such as wind strength had to be expressed uniformly in a simplified model, it was impossible to raise the level of estimate accuracy (Figure V.1a). Using this new technology, the high-dimensional data, which incorporates a variety of measurement data, is automatically grouped by similar meteorological and hydrographical conditions and then machine learning and estimations are carried out on each group individually (Figure V.1b).
+
+Overly prioritizing actual measured data for machine learning can create a problem where the estimation accuracy goes down for conditions which have not been experienced and there is no measurement data. This problem is solved by automatically adjusting the group boundaries so that no group has data that matches measurement data too closely. This enables a uniform reduction in prediction error.
+
+![Figure V.1: Comparison of a physics model and newly developed technology for fuel efficiency estimation. The figure consists of two side-by-side graphs. Graph (a) 'Physics model' shows fuel efficiency [m/L] on the y-axis (High to Low) and wind speed [m/s] on the x-axis (Weak to Strong). It features a red curve representing the 'Estimated value' and grey dots representing 'Measured value'. A callout box states: 'There are strong limitations on a physics model, leading to a large margin of error'. Graph (b) 'Newly developed technology' shows the same axes. It features a red curve that is more closely fitted to the measured data points. The data points are grouped into three blue circles, labeled 'Automatic grouping'. A callout box states: 'Margin of error is smaller because separate estimates can be done for strong and weak winds'. A large grey arrow points from graph (a) to graph (b). The text 'L.1505(18)_FV.1' is located at the bottom right of graph (b).](183007754364096b2d89f42200cf870f_img.jpg)
+
+Figure V.1: Comparison of a physics model and newly developed technology for fuel efficiency estimation. The figure consists of two side-by-side graphs. Graph (a) 'Physics model' shows fuel efficiency [m/L] on the y-axis (High to Low) and wind speed [m/s] on the x-axis (Weak to Strong). It features a red curve representing the 'Estimated value' and grey dots representing 'Measured value'. A callout box states: 'There are strong limitations on a physics model, leading to a large margin of error'. Graph (b) 'Newly developed technology' shows the same axes. It features a red curve that is more closely fitted to the measured data points. The data points are grouped into three blue circles, labeled 'Automatic grouping'. A callout box states: 'Margin of error is smaller because separate estimates can be done for strong and weak winds'. A large grey arrow points from graph (a) to graph (b). The text 'L.1505(18)\_FV.1' is located at the bottom right of graph (b).
+
+**Figure V.1 – Physics model vs the newly developed technology**
+
+### V.5 Results
+
+Undertaking a joint research with Tokyo University of Marine Science and Technology, Fujitsu Laboratories applied this technology to measured data held by the university from actual ships at sea, including wind and wave data and ship's fuel consumption and accurately estimated the ship's speed performance and fuel consumption performance to within a 5 per cent margin of error. By combining this technology with the Tokyo University of Marine Science and Technology's weather routing simulation, they verified that, for a Pacific ocean shipping route from Tokyo to Los Angeles, taking an optimal route based on the ship's performance as determined by this technology, fuel consumption could be cut by about 5%, as opposed to the most direct route, which greatly reduces both fuel costs and CO2 emissions.
+
+Feeding back data from voyages by previously developed ships into the ship design process, this technology can enable the design of safe ships with high fuel efficiency. In addition, changes in ship performance before and after maintenance and also before and after applying various fuel-efficient technologies can be quantitatively evaluated.
+
+### V.6 Future plans
+
+Fujitsu Laboratories will continue to improve prediction accuracy through joint research with the Tokyo University of Marine Science and Technology. In addition, trials were planned to be carried out in 2016 with a number of ship types and routes, aiming to offer services through Fujitsu's location information cloud service (FUJITSU Intelligent Society Solution SPATIOWL).
+
+## Bibliography
+
+- [b-African Journal] African Journal of Agricultural Research (2001), *Information and communication technology for fisheries industry development in Malaysia*, Vol. 6 (17), pp. 4166-4176, 5 September.
+[http://www.academicjournals.org/article/article1380811163\\_Omar%20et%20al.pdf](http://www.academicjournals.org/article/article1380811163_Omar%20et%20al.pdf)
+- [b-ECA, 2009] Economic Commission for Africa, Economic Report on Africa 2009; Developing African Agriculture Through Regional Value Chains, UNECA 2009, Addis Ababa, Ethiopia.
+[http://www.uneca.org/sites/default/files/PublicationFiles/era2009\\_eng\\_full.pdf](http://www.uneca.org/sites/default/files/PublicationFiles/era2009_eng_full.pdf)
+- [b-FAO, 2007] Food and Agriculture Organization of the United Nations (2007), *Information and communications technologies benefit fishing communities*. New directions in Fisheries – A series of Policy Briefs on Development Issues, No. 07, Rome. 12 pp.
+- [b-FAO, 2009] Food And Agriculture Organization of the United Nations, *Climate change implications for fisheries and aquaculture* (2009).
+[http://www.fao.org/fileadmin/user\\_upload/newsroom/docs/FTP530.pdf](http://www.fao.org/fileadmin/user_upload/newsroom/docs/FTP530.pdf)
+- [b-FAO, 2014] Food and Agriculture Organization of the United Nations. *Climate Change Adaptation in Fisheries and Aquaculture, Compilation of initial examples* (2014).
+
+- [b-FFMA] The M. S. Swaminathan Research Foundation (MSSRF), *Fisher Friend Mobile Application*.
+
+- [b-Fujitsu] Fujitsu, *Fujitsu develops High-Accuracy Fuel Efficiency Estimates through a ship's operational data* (2016).
+
+- [b-IEEE Xplore] IEEE Xplore digital Library, *ICT for fisheries — Environment friendly way: Pilot experience in Raigadh* (2013).
+
+- [b-Indian University] Indian University, *Aquaculture, Poverty Impacts and Livelihoods, Digital Library of the Commons*.
+- [b-IPCC] Intergovernmental Panel on Climate Change, assessment reports Working Group II: Impacts, Adaptation and Vulnerability.
+
+- [b-NICCD] NEXUS for ICTS, Climate Change and Development (NICCD), *ICTs and Food Security: Connecting the Dots* (2012).
+
+- [b-NORDEN, 2009] Nordic Council of Ministers, Nordic Innovation Centre, *Innovation in the Nordic marine sector* (2009).
+[http://www.matis.is/media/utgafa/krokur/innovation\\_in\\_the\\_nordic\\_marine\\_sector\\_final\\_report\\_web.pdf](http://www.matis.is/media/utgafa/krokur/innovation_in_the_nordic_marine_sector_final_report_web.pdf)
+- [b-OECD] Organisation for Economic Co-operation and Development, *Climate change and fisheries*.
+
+- [b-The Fish Site] The Fish Site, *The Use of Drones for Tackling Illegal Fishing* (2014).
+
+
+- [b-TheHindu] The Hindu News, *mKRISHI mobile app to guide aqua farmers* (2015).
+[](http://www.thehindu.com/news/cities/Vijayawada/mkrishi-mobile-app-to-guide-aqua-farmers/article7412489.ece)
+- [b-UNEP] United Nations Environment Programme
+[](https://web.unep.org/climatechange/mitigation)
+- [b-WMO] World Meteorological Organization
+[](https://www.wmo.int/pages/index_en.html)
+- [b-WHO 2001] World Health Organisation (2001), *The state of food security*.
+[](http://www.fao.org/docrep/005/y4671e/y4671e06.htm)
+- [b-Wiley] Wiley Online Library, *Vulnerability of national economies to the impacts of climate change on fisheries*.
+[](http://onlinelibrary.wiley.com/doi/10.1111/j.1467-2979.2008.00310.x/full)
+- [b-WRI] World Resources Institute, *ICTs as a Key Technology to Help Countries Adapt to the Effects of Climate Change*.
+[](http://www.wri.org/our-work/project/world-resources-report/icts-key-technology-help-countries-adapt-effects-climate)
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.155-201611-I_PDF-E/raw.md b/marked/L/T-REC-L.155-201611-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..03d77e5b86afadead04bc4344d43f7b59e77dd00
--- /dev/null
+++ b/marked/L/T-REC-L.155-201611-I_PDF-E/raw.md
@@ -0,0 +1,536 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.155**
+
+(11/2016)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+Optical fibre cables – Guidance and installation technique
+
+# --- **Low impact trenching technique for FTTx networks**
+
+Recommendation ITU-T L.155
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+## ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
+
+| | |
+|-------------------------------------------------------|--------------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node element (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.155
+
+# Low impact trenching technique for FTTx networks
+
+## Summary
+
+With the miniaturization of the telecommunication infrastructure, i.e., with mini-ducts and mini-cables, it has been possible to use a low impact trenching technique to carry out all the steps of the network construction in a single day, in a less invasive way in terms of time and space, and with a smaller construction site than for the previous trenching technologies. Recommendation ITU-T L.155 describes this trenching technique, which allows the easy installation, in narrow trenches, of underground optical cables and mini-cables in ducts or mini-ducts or directly buried. This type of narrow trench allows the use of reduced dimension machinery in small-sized roads, typically those in cities, producing a lower quantity of waste material and so should be used in urban areas. This technology is mainly characterized by the simultaneous work of a suction machine and a trench saw, which allows for the possibility of opening and closing the work site the same day.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|------------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.155/L.83 | 2010-07-29 | 15 | 11.1002/1000/10916 |
+| 2.0 | ITU-T L.155 | 2016-11-13 | 15 | 11.1002/1000/13113 |
+
+## Keywords
+
+Environmental low-impact, FTTx network, reduction, urban trenching technique.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2017
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|------|-----------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| 3.1 | Terms defined elsewhere ..... | 1 |
+| 3.2 | Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 1 |
+| 5 | Conventions ..... | 1 |
+| 6 | The urban trenching cable-laying technique..... | 2 |
+| 6.1 | Preparatory step ..... | 2 |
+| 6.2 | Excavation requirements ..... | 3 |
+| 6.3 | Working phases for laying the infrastructure or cables..... | 3 |
+| 6.4 | Identification..... | 4 |
+| 6.5 | Resurfacing..... | 4 |
+| 6.6 | Maintenance ..... | 4 |
+| 7 | Daily urban trenching methods and procedures ..... | 5 |
+| 8 | Daily urban trenching application criteria ..... | 5 |
+| 8.1 | Entry to existing manholes or chambers ..... | 5 |
+| 8.2 | Road crossings..... | 5 |
+| 9 | Practical rules for the correct realization of micro-trenches..... | 5 |
+| | Appendix I – Italian experience regarding "one day" reduced mini trench..... | 7 |
+| | Appendix II – Effect of micro-trenches on road pavements ..... | 10 |
+| II.1 | Scope ..... | 10 |
+| II.2 | Study for the optimization of the performance of micro-trench/pavement system ..... | 10 |
+| II.3 | Effects of thermal strains on the performance of the micro-trench/pavement system ..... | 13 |
+| II.4 | Effects of the micro-trench on the drainage conditions of the roadway..... | 14 |
+| | Bibliography..... | 15 |
+
+
+
+## Recommendation ITU-T L.155
+
+## Low impact trenching technique for FTTx networks
+
+## 1 Scope
+
+This Recommendation:
+
+- gives advice on general requirements of the main phases in which the work can be divided;
+- gives advice on the methods and procedures for performing the work;
+- gives some application criteria;
+- describes situations where a low impact urban trenching technique is recommended.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T L.260] Recommendation ITU-T L.260/L.84 (2010), *Fast mapping of underground networks*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following term:
+
+**3.2.1 urban trenching technique:** It is characterized by a width of maximum 5 cm and typically a depth of maximum 30 cm.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+FTTx Fiber To The x, where 'x' stands for the final location on the end-user side
+
+GPR3D Ground Penetration Radar 3 Dimensions
+
+NGN Next Generation Network
+
+## 5 Conventions
+
+None.
+
+## 6 The urban trenching cable-laying technique
+
+The urban trenching technique should be applied especially in urban areas, where car traffic and shop presence is very high and on routes that generally involve asphalted surfaces such as roads and sidewalks with a base of compact material (asphalt or concrete).
+
+It is not recommended that the technique be used on routes where the soil subgrade is sandy, gravelly or contains medium-sized cobbles (i.e., measuring 10 to 20 cm in diameter).
+
+The main advantages of this technique over traditional cable-laying technologies are the very small obstruction of the road and the low impact on traffic due to the road construction site cleaning, the immediate removal of debris and the quickness of opening and closing the road construction site.
+
+The urban trenching technique is normally carried out by simultaneously cutting through the paving and digging a trench whose depth and cross-section vary in accordance with the number of ducts to be laid: depth is $\leq 30$ cm, while cross-section can be $\leq 5$ cm. In order to guarantee a protection against impact resulting from road-repairing, the depth of the laid infrastructure should be maintained constant at a known level that should be 5 cm deeper than the foreseen asphalt cutting depth normally specified for road surface repair works. Figure 1 shows some possible duct and mini-duct installation configurations that can be used.
+
+
+
+Figure 1: Two 3D cross-sectional diagrams of urban trenching. The left diagram shows a narrow vertical trench cut through a grey asphalt layer into brown soil, containing a single blue duct with smaller cables inside. The right diagram shows a similar trench containing a vertical stack of five small yellow mini-ducts. Both diagrams illustrate the narrow width and specific depth of the trenching technique.
+
+**Figure 1 – Examples of urban-trenching duct installation configuration**
+
+Any crossings through unpaved sections (which should in any case have a compact subgrade) should be carried out using the same technique.
+
+### 6.1 Preparatory step
+
+Generally, a detailed survey of the route should be carried out, the purpose of which is to identify the work required to be done before starting cable installation operations. Such work could include, for instance, the preparation at bridges, or at road or rail crossings. Further, it is necessary to determine closure locations and section ends.
+
+The location of all underground utilities should be determined in order to establish the correct route for the trench. This is normally accomplished by means of cartographic documentation provided by the administrations that own the road or by the utility company, and/or through instrumented field surveys. The detailed utilities investigation should be made with the ground penetration radar 3 dimensions (GPR3D) fast solution technique [ITU-T L.260].
+
+The designed route should be free from sharp changes in direction. Where such changes are unavoidable, they should be made by means of cuts angled so as to comply with the minimum bend radii specified for the ducts and cables.
+
+Where necessary, the contractor can take core samples along the planned route to determine the type of subsoil or as a further method of checking for obstacles. A GPR3D fast solution should be used in order to detect ground characteristics [ITU-T L.260].
+
+### 6.2 Excavation requirements
+
+The following requirements should be observed in cutting while applying the urban trenching technique:
+
+- comply with all provisions and regulations established by the administrations involved as regards excavation permits, schedules, etc.;
+- place the barriers and road signs required by current legislation, regulations and the administrations involved, in clearly visible locations around the excavation site.
+
+Generally, the site is opened and closed during the same day, so the excavation should not remain open during the night.
+
+### 6.3 Working phases for laying the infrastructure or cables
+
+All the construction activities should be split in separate operational steps involving subsequent phases (Figure 2). This synergism should allow:
+
+- flexible use of smaller machines;
+- reductions of time and space occupancy.
+
+
+
+The diagram illustrates the logical sequence of four working phases for urban trenching. From left to right, the phases are: **Backfilling**, where a yellow truck with a crane is positioned; **Pipes laying**, where a yellow truck with a large reel of pipe is shown; **Suction**, where a yellow suction truck is connected via a long blue flexible tube; and **Trenching**, where a small black and white trenching machine is shown, also connected to the suction tube. The ground is represented by a horizontal line with diagonal hatching below it. The label 'L.155(16)\_F02' is in the bottom right corner.
+
+Figure 2 – Daily reduced trenching technique logical scheme. The diagram shows four sequential phases of a trenching operation on a road surface. From left to right: 1. Backfilling: A yellow truck with a crane arm is shown. 2. Pipes laying: A yellow truck with a large reel of pipe is shown. 3. Suction: A yellow suction truck is shown, connected by a long blue flexible tube. 4. Trenching: A small black and white trenching machine is shown, also connected to the blue suction tube. The ground is represented by a horizontal line with diagonal hatching below it. The label 'L.155(16)\_F02' is in the bottom right corner.
+
+Figure 2 – Daily reduced trenching technique logical scheme
+
+#### 6.3.1 Simultaneous trenching dig phase and cleaning phase
+
+It is recommended that the urban trenching technique be characterized by the simultaneous work of the trench saw and the suction machine. This combined action should allow the waste material to be collected while produced by the saw, leaving the site clean immediately after the end of the trenching phase and completely removing dust problems.
+
+##### 6.3.1.1 Trenching dig phase
+
+The urban trench should be made using a small size saw disk, mounted on small dimension operating machines. The trenching cut should not damage the urban road pavement near the dig section. The saw should be inside a protective carter connected via a flexible tube to a vacuum pump installed on the suction machine.
+
+##### 6.3.1.2 Spoil suction phase
+
+The debris suction and the digging phase should be performed simultaneously in order to accelerate the trench cleaning action.
+
+Spoil should be transported to authorized disposal sites in accordance with current local laws. The trench cleaning shall be made with automated methods in order to avoid or limit troubles to people and environmental pollution.
+
+At the end of this phase, the trench cross-section should be completely free of stones and the bottom of the trench should be clean. The trench and the near zones should be completely clean of debris that could reduce the backfilling material features.
+
+#### 6.3.2 Ducts or cable laying
+
+The reel can be mounted aboard a machine subsequent to the saw, so that the duct(s) or cable can be automatically fed into the trench, via a suitably shaped guide integrated into the ploughshare, as the excavation proceeds.
+
+The equipment and procedures used for this purpose should guarantee that:
+
+- initial duct or cable configuration and position in the urban trenching technique are maintained along the entire route unless special circumstances dictate otherwise;
+- if obstacles or situations are encountered which make it impossible to proceed with the urban trenching technique, the reel (and thus the ducts or the cable) can be removed from the machine without having to cut the ducts, thus ensuring that cable deployment can be continued using conventional methods without performing splices that are unnecessary from the technical standpoint.
+
+#### 6.3.3 Backfilling phase
+
+After the ducts, mini-ducts or cables are installed, the trench should be backfilled with a highly resistant and fast-hardening material. The trench backfilling shall be made with rapid cement mortar casting. The mortar should be quick setting, with fluid consistency, containing cement with high strength, selected aggregate and special additives. Bitumen material shall be avoided. The backfilling material should have particular features in order to assure vehicle traffic restoration within two to four hours and it shall present high compatibility with mechanical and visual characteristics of existing pavement surface.
+
+##### 6.3.3.1 Mortar features
+
+The cement mortar should have the following features:
+
+- high compressive strength ( $> 50 \text{ N/mm}^2$ ), better than jet concrete ( $30 \text{ N/mm}^2$ ) and similar to precast concrete, in order to protect the infrastructure below;
+- slip resistance similar to that of asphalt (60) – [b-BS EN 1340:2003];
+- it should undergo controlled shrinkage in order to adhere to trench walls with sufficient coupling ("silos" effect);
+- intrinsic fluidity of the material in order to fill completely the trench;
+- high resistance to thermal variation, above all to frost and thaw cycles;
+- easily removable, in case of pavement resurfacing, without causing damage to the infrastructure.
+
+### 6.4 Identification
+
+The urban trenching technique should not need any kind of identification, because the backfilling material laying is just an identification element for the new infrastructure.
+
+### 6.5 Resurfacing
+
+The urban trenching technique should not need pavement resurfacing. That should be achieved with backfilling material, both on the road and on the sidewalk. At the end of the activity there should not be cracks, steps or smear. The new pavement colour should be similar to the current one.
+
+### 6.6 Maintenance
+
+The maintenance of buried cables and ducts should be performed with the same techniques and tools as for normally buried infrastructures because the backfilling concrete mortar should be easily removable.
+
+## **7 Daily urban trenching methods and procedures**
+
+The debris suction phase and the cutting phase should be executed at the same time. All phases described in clause 6.3 should be subsequent, but if the environmental conditions, like urban traffic, are very hard, or because of administration prescriptions allowing only limited site lengths, suction/digging phases and pipes laying/backfilling can be made at different times.
+
+## **8 Daily urban trenching application criteria**
+
+Some criteria for specific applications of the urban trenching technique are given in the following clauses.
+
+### **8.1 Entry to existing manholes or chambers**
+
+Connection to an existing prefabricated structure such as a manhole, pit or chamber should be accomplished by means of a conventional excavation approximately 2 m long and dropping gradually from the urban trenching technique to points of access to the prefabricated structure in such a way as to comply with minimum duct or cable bend radii requirements. Ducts and cables should enter the prefabricated structure at a suitable distance (e.g., 20 cm) from the structure's interior floor. Ducts should be secured with cement mortar on both the internal and external sides of the prefabricated structure. Inside the prefabricated structure, individual ducts should be separated and located at a horizontal distance of some centimetres (e.g., 3-4 cm from each other) and they should protrude (e.g., 15-20 cm) inside the prefabricated structure. Once ducts have been terminated in the prefabricated structure, the latter should be surfaced and smoothed.
+
+### **8.2 Road crossings**
+
+New road crossings should be cut using the same methods envisaged for lengthwise excavations. Where existing conventional type road crossings are used (e.g., with ducts located at a depth of approximately 1 m from the road surface), the two different depths should be joined by an excavation which drops gradually for a length of at least 2 m, complying with the minimum bend radii (see clause 8.1). In case of crossing, any cables should be protected with appropriate ducts along the whole crossing length.
+
+## **9 Practical rules for the correct realization of micro-trenches**
+
+The following practical rules for the correct realization of micro-trenches within the road pavements are recommended:
+
+- in general road pavements designed and constructed using standard practices ensure better performance of the system, in terms of the stress levels induced by the vehicles in transit both on the micro-trench filling material and at the micro-trench/pavement interface;
+- heavy vehicles in transit may induce stress variations on the micro-trench filling material and at the micro-trench/pavement interface only when the wheels of the vehicles are located within a zone of impact within 0.5 m of the micro-trench. Therefore, the most recommended position for the micro-trench is the one that maximizes the distance between the micro-trench itself and the vehicle tire tracks. In practice, this translates into the following options:
+ - 1) positioning the micro-trench at the centerline of the lane;
+ - 2) positioning the micro-trench on the lateral margin of the outer driving lane (often under the line marking the outer edge of the driving lane) if the lane is wide enough to ensure an adequate distance between the outer wheels of the vehicle and the edge of the carriageway (at least 0.5 m). This option limits the visual impact of the micro-trench. If the roadway is on an embankment, this solution allows use of the micro-trench filling material as a containment element at the outer side of the embankment.
+
+These options are illustrated in Figure 3.
+
+
+
+The image consists of two side-by-side photographs. The left photograph shows a road corner with a curved sidewalk made of light-colored pavers. A micro-trench is visible along the edge of the road, near the curb. In the background, there is a building, some trees, and a speed limit sign indicating 50. The right photograph shows a straight section of a paved road. A micro-trench is visible running parallel to the road edge, near the shoulder. The road has a white line along the edge, and there is a grassy area and trees in the background.
+
+Two photographs showing micro-trenching options on roads.
+
+**Figure 3 – Examples of micro-trench positioning**
+
+## Appendix I
+
+### Italian experience regarding "one day" reduced mini trench
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The capabilities of realizing new infrastructures with lower environmental impact, and the tendency to use digging technologies less invasive in terms of time and space of road occupation and restoration, have driven network construction technologies towards the miniaturization of primary elements. In Italy, an innovative approach is developed to carry out all steps of the network construction, for fiber to the x, where 'x' stands for the final location on the end-user side (FTTx) applications, in a single day, with big advantages in terms of environmental and social costs.
+
+In order to overcome all the problems caused by traditional digging technologies, each step of the process has been analysed. Thanks to the simultaneous and synergic use of a trench saw and a suction pump, the digging work can be completed very quickly, with reduced-dimension machinery, and with no residual material to be removed. The last element of this solution is the innovative material used to fill in the trench, with a very fast hardening time to allow to complete the work in a few hours, restoring the pavement to the previous state. This technique allows opening and closing digging works in only one day.
+
+With a global approach, the problem of working downtown is traduced into an effort of reducing whole critical dimensions related to the usual trenching machines, beginning with trench dimensions.
+
+This kind of new trenching technique is characterized by a maximum width of 5 cm and a maximum depth of 30 cm.
+
+The true innovation during the trenching phase is the simultaneous operation of a powerful suction machine and a trench saw, as shown in Figure I.1.
+
+
+
+A photograph showing a yellow trench saw and suction machine unit on a trailer. The machine is positioned on a street, with a worker in an orange safety suit operating it. A blue and white traffic sign is visible in the foreground. The machine is connected to a suction hose and is positioned near a building.
+
+A yellow trench saw and suction machine unit on a trailer, with workers in orange safety gear operating it on a street. The machine is connected to a suction hose and is positioned near a building. A blue and white traffic sign is visible in the foreground.
+
+**Figure I.1 – Trench saw combined with suction machine**
+
+This combined action allows the waste material to be collected as it is produced by the saw, leaving the site clean immediately after the end of the trenching phase and completely removing dust problems. Figure I.2 shows clearly the cleaning of the site and inside the trench.
+
+
+
+Figure I.2: Cleaning of the site and inside the trench. The left image shows a street corner with a small orange machine and two workers in orange safety vests cleaning a trench. The right image is a close-up of the trench interior, showing the rough, excavated material.
+
+**Figure I.2 – Cleaning of the site and inside the trench**
+
+Another important innovation is related to pavement re-establishment. According to traditional techniques, the trench is normally filled with excavated material and binder on top, and finally a layer of pavement is posed. With traditional technologies, pavement can be restored only after the backfilling material is ready and usually it takes at least 24 hours.
+
+With the new Italian trenching system, thanks to an innovative material which has mechanical and esthetical characteristics similar to the pavement, the trench is completely filled in one operation and with just one material. Moreover, the fast hardening time, main characteristic of this material, allows the closure of the working site in just a few hours (Figure I.3).
+
+
+
+Figure I.3: Innovative material before and after hardening completed. The left image shows the trench filled with a dark, granular material. The right image shows the same trench after the material has hardened, appearing as a smooth, dark, and solid surface.
+
+**Figure I.3 – Innovative material before and after hardening completed**
+
+Due to the behaviour of this innovative material, the site can be opened to the traffic just a couple of hours after the filling. Its physical and mechanical characteristics, combined with the esthetical result, avoid laying of the asphalt carpet, reducing operating phases and troubles for citizens.
+
+A new mixing machine adapted to the type of material has been developed (Figure I.4). The mixing machine features, which can be installed on ordinary trucks, several solutions optimal for trench filling while keeping the site clean.
+
+
+
+A yellow mixing machine is mounted on the back of a truck. A worker wearing an orange high-visibility safety vest is operating the machine, which has a large cylindrical tank and various pipes and nozzles. The truck is parked on a paved road, and a single orange traffic cone is placed on the ground next to it. In the background, there is a modern building and some trees.
+
+A yellow mixing machine mounted on a truck, with a worker in an orange safety vest operating it. The machine is positioned on a road, and a traffic cone is visible nearby.
+
+**Figure I.4 – The mixing machine**
+
+The whole system can thus be divided into two different modules: the first, which will perform the trenching phase, is composed by the saw and the suction machine; the second, which will perform re-establishing phase, is composed by one truck with the mixing machine. These two modules can work in line or at different times/places, allowing major flexibility, but anyway guaranteeing a better solution.
+
+The new Italian reduced trenching technique has introduced a new point of view on trenching techniques, turned into a less invasive way. Due to the combined use of innovative instruments and materials, the construction site (of very reduced dimensions) can be opened and closed in a single day of work, thus minimizing the impact for the community. Examples of these new trenching sites, on the road and on the sidewalk, are shown in Figures I.5.a and I.5.b, respectively. In these pictures a site in an urban area of Milan is shown, as well as the advantages of the new digging technique with respect to the traditional one, as discussed above.
+
+
+
+Two side-by-side photographs. Photograph A (left) shows a yellow truck parked on a road. A red and white striped barrier is set up in front of the truck, and a worker in an orange safety vest is visible near the barrier. Photograph B (right) shows a worker in an orange safety vest operating a yellow machine on a sidewalk. The machine has a large hose connected to it, and the worker is standing next to it. The background shows a fence and some trees.
+
+Two side-by-side photographs labeled A and B. Photograph A shows a yellow truck parked on a road, with a red and white striped barrier set up in front of it. Photograph B shows a worker in an orange safety vest operating a yellow machine on a sidewalk, with a large hose connected to it.
+
+L.155(16)\_FI.5
+
+**Figure I.5 – The new digging technique at a worksite in an urban area of Milan**
+
+## Appendix II
+
+## Effect of micro-trenches on road pavements
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### II.1 Scope
+
+The goal of this work is to present a proposal to define the best technological characteristics and features for micro-trenches in terms of the location of the micro-trench with respect to the road layout and types of filling materials. This proposal is based on a specific numerical analysis study to evaluate the stress changes that may occur on the road pavement upon construction of the micro-trench structures.
+
+### II.2 Study for the optimization of the performance of micro-trench/pavement system
+
+The effect of the realization of a micro-trench on the roadway can be optimized by taking into account three aspects that affect the performance of the micro-trench/pavement system:
+
+- 1) type of the road pavement;
+- 2) position of the micro-trench with respect to the vehicle tire tracks;
+- 3) type of micro-trench filling material.
+
+In the following clauses, they are separately described.
+
+#### II.2.1 Type of the road pavement
+
+A typical asphalt road construction is multi-layered in form, comprising bitumen-bound and unbound materials. However, In Italy, the experience gained working on site with completed micro-trenches, showed that in urban areas, road pavement could vary significantly. The effect of the presence of a micro-trench on the pavement response depends on the type of roadway layers. In particular, the following were considered, as all of them have been found during the construction of micro-trenches in urban areas: P1) consists of an asphalt layer of 5 cm above the natural soil; P2) consists of an asphalt layer of 5 cm over an unbounded road base of 25 cm, above the natural soil; P3) consists of an asphalt layer of 5 cm, over a binder asphalt of 10 cm, over an unbounded road base of 15 cm, above the natural soil.
+
+The goal was to identify the most vulnerable roadway types during the construction of micro-trenches and to minimize the potential extent of damage on them.
+
+#### II.2.2 Position of the micro-trench with respect to vehicle tire tracks
+
+Due to different stiffness of road pavement materials and of the micro-trench filling mixtures, the presence of the latter can give rise to stress concentrations in the vicinity of the vertical surfaces at the contact surface between the pavement and micro-trench, during vehicles' transit. Such concentrations are identified as the possible cause of the progressive deterioration of the road surface and of the filling material. The magnitude of these effects is related to the geometrical relationship between the depth of the micro-trench and the distance of the micro-trench from the load application on the road surface (i.e., wheel-pavement contact area). If the vehicles are circulating sufficiently far from the micro-trench, or if the area of influence of the moving load is located outside the excavation area, then, the variations of the stress state are negligible. It is important to assess quantitatively the extent of the area of impact of the loads transmitted by vehicles driven on the roadway, alongside the amount of stress concentrations produced at the micro-trench/pavement contact surface.
+
+The goal was to establish practical rules for the correct positioning of the micro-trench with respect to the road lanes, and therefore to the distance of the micro-trench from the vehicles' tires. In particular, three possible positions of the micro-trench were considered (see Figure II.1): G1) micro-
+
+trench placed at the centerline of the lane; G2) micro-trench placed under the tires of vehicles in transit; G3) micro-trench placed in proximity of one of the tires of the vehicles in transit.
+
+
+
+Figure II.1: Positions considered for the construction of a micro-trench. The diagram shows three scenarios (G1, G2, G3) for micro-trench placement relative to a road centerline (dashed line) and tire footprints (blue rectangles). G1 shows the micro-trench at the centerline. G2 shows the micro-trench under the tires. G3 shows the micro-trench in proximity of one tire. Dimensions Hr (length) and br (width) of the tire footprint are indicated. A horizontal distance 'a' is shown from the centerline to the edge of the micro-trench in G1 and G3. A vertical distance 'd' is shown from the centerline to the edge of the micro-trench in G3. A legend at the bottom left states 'Hr, br: Length and width of tire footprint'. A label 'L.155(16)\_FII.1' is in the bottom right.
+
+**Figure II.1 – Positions considered for the construction of a micro-trench**
+
+#### II.2.3 Types of micro-trench filling material
+
+Stiffness variations between the micro-trench filling materials and the road paving materials may produce stress concentrations at the micro-trench/pavement contact interface.
+
+The goal was to identify the type of filling material that minimizes such stress concentrations on the roadway, and, therefore, minimizes the potential extent of damage. In order to achieve this goal, four types of filling materials for micro-trenches were considered: R1) micro-trench entirely filled with special mortar; R2) micro-trench filled with special mortar and with modified asphalt for the remaining 5 cm to the road surface; R3) micro-trench entirely filled with modified asphalt; R4) micro-trench filled with gravel and with modified asphalt for the remaining 5 cm to the road surface.
+
+#### II.2.4 A 3D finite element model for evaluating the performance of the micro-trench/pavement system
+
+In order to evaluate the performance of the roadway pavement after the realization of a micro-trench, a 3D finite element modelling study was carried out, considering a portion of a roadway lane with known mechanical and geometrical characteristics (Figure II.2).
+
+
+
+Figure II.2: Portion of roadway lane considered and meshed domain. The figure contains two 3D views of a road segment. The left view shows a solid model of the road with a dashed line representing the 'Road axis' and arrows pointing to the 'Position of wheels'. The right view shows the same road segment as a meshed domain with a grid of elements. A dashed line represents the 'Road axis'. A label 'L.155(16)\_FII.2' is in the bottom right.
+
+**Figure II.2 – Portion of roadway lane considered and meshed domain**
+
+For the traffic loads, the following variables were considered: ordinary vehicles and heavy vehicles (e.g., trucks); speed conditions within the limits required by traffic laws; straight and curved roadway geometries; ascent and descent conditions (simulating acceleration and deceleration).
+
+The numerical analyses were focused on identifying the design strategies in the realization of micro-trenches to minimize the probability of failures and cracking of the road surface.
+
+Examination of the results enabled identification of the most critical conditions for the road pavement according to the type of road material layers, type of filling materials and trench positions relative to the location of the vehicle tire tracks.
+
+#### **II.2.5 Summary of results**
+
+The effects of the various conditions considered in the numerical analysis study are summarized in the following clauses and reported in Table II.1.
+
+##### **II.2.5.1 Types of road pavement**
+
+Considering the three types of road pavement layers (P1, P2 and P3), the micro-trench entirely filled with the R1 material (special mortar), and the three geometrical conditions for the position of the micro-trench (G1, G2 and G3), the general performance of the micro-trench/pavement system was found to improve from the pavement type P1 to P3. Therefore, it was concluded that roadways with pavement layers that are similar to the standards imposed by Italian Technical Regulation are less vulnerable, as might be expected.
+
+##### **II.2.5.2 Position of the micro-trench with respect to the vehicle tire tracks**
+
+The areas of impact of the load transmitted from the tires to the roadway are relatively narrow, only a little wider than the actual areas of the tire footprint; consequently, the stress increments are concentrated in the immediate vicinity of the tire itself.
+
+Thus, the geometry G2 (micro-trench under the wheel) can be indicated as the most critical one for the possible phenomenon of failure involving the filling material. The geometry G3 (micro-trench next to the lateral border of the load area) can be indicated as the most critical one for the phenomenon of detachment along the vertical contact plane between the pavement and the micro-trench. It is possible to conclude that the most recommended position for the micro-trench is G1, in which the micro-trench is located sufficiently far from the vehicles' wheels.
+
+##### **II.2.5.3 Type of micro-trench filling material**
+
+The problems related to the increase of shear and tensile stresses are located in a very shallow area of the micro-trench (with a thickness lower than 5 cm). The replacement of the first 5 cm of excavation with filling material characterized by a more ductile and deformable behavior (such as modified asphalt) allows the reduction of stress concentrations on the micro-trench, with a positive effect on the overall behavior of the system.
+
+**Table II.1 – Technical recommendations for minimizing the impact of micro-trench construction on a roadway**
+
+| | Considered Condition | Highly Recommended | Recommended | Not Recommended |
+|-----------------------|-------------------------------------------------------------------------------------------|--------------------|-------------|-----------------|
+| Pavement layers | P1: Asphalt above natural soil | | X | |
+| | P2: Asphalt layer (5 cm)+unbounded road base (25 cm)+natural soil | | X | |
+| | P3: Asphalt layer (5 cm)+binder asphalt (10 cm)+ unbounded road base (15 cm)+natural soil | X | | |
+| Filling material | R1: Special mortar | | X | |
+| | R2: Modified asphalt + special mortar | X | | |
+| | R3: Modified asphalt | X | | |
+| | R4: Modified asphalt + gravel | X | | |
+| Micro-trench position | G1: Centerline of the road lane | X | | |
+| | G2: At the bottom of a vehicle's wheel | | | X |
+| | G3: Close to a vehicle's wheel | | | X |
+
+### II.3 Effects of thermal strains on the performance of the micro-trench/pavement system
+
+It is well known that in the presence of significant temperature variations on the pavement surface, the roadway is subject to phenomena associated with thermal expansion/contraction. Therefore, a specific study has been devoted to understand if the presence of an inclusion of material within the pavement, with different thermo-mechanical behavior, can give rise to differential deformation at the contact interface between micro-trench and the pavement, and, thus the onset of tensile stresses that can eventually cause cracks and damage on the road surface.
+
+To quantitatively assess the extent of these effects, a series of numerical analyses have been conducted in parametric form at the variation of the thermal conditions imposed on the surface of the pavement and of the characteristics of conductivity and thermal expansion of the materials. In particular, this was obtained by varying the relationships between: i) the coefficient of thermal expansion of the pavement and of the micro-trench filling material; ii) thermal conductivity of the pavement and of the micro-trench filling material; iii) stiffness of the pavement and of the micro-trench filling material.
+
+#### II.3.1 Technical guidance to minimize thermal effects
+
+In the presence of a micro-trench entirely filled with material of R1 type (special mortar), differential thermal strains were observed, due to the higher stiffness of the mortar with respect to the one of the pavement materials. However, this effect was localized at the most superficial part of the pavement for a depth that does not exceed 5 cm.
+
+The substitution of the first 5 cm of the filling material with modified asphalt (which is characterized by mechanical characteristics more similar to those of the pavement upper layers) allowed complete elimination of the horizontal stress increments due to the differential thermal strains.
+
+### **II.4 Effects of the micro-trench on the drainage conditions of the roadway**
+
+In principle, a micro-trench installed parallel to the roadway, on the outer side, could be a barrier to water drainage towards the outside of the carriageway. This phenomenon may be significant in the presence of pavings realized with draining pavement, where the layer of draining asphalt is characterized by a hydraulic conductivity greater than that of the mixtures used as filling materials.
+
+To quantitatively assess the impact of the presence of a micro-trench on the pore pressure regime and on the velocity of seepage within the road pavement, a specific study was performed by varying: i) the relationship between the depth of the micro-trench and the surface of the drainage layers; ii) the relationship between the hydraulic conductivity of the micro-trench filling materials and of the drainage layers; iii) the boundary conditions imposed at the road surface (e.g., rainfall rate).
+
+#### **II.4.1 Technical guidance to improve drainage conditions**
+
+The results of the study demonstrated that positioning the micro-trench on the outer side of the lane did not induce any appreciable change in the conditions of drainage of the pavement, even for the case of fully waterproof filling material for the entire thickness of the micro-trench since the seepage takes place predominantly in the vertical direction.
+
+## Bibliography
+
+- [b-ITU-T L.153/L.48] Recommendation ITU-T L.153/L.48 (2003), *Mini-trench installation technique*.
+- [b-ITU-T L.257/L.39] Recommendation ITU-T L.257/L.39 (2000), *Investigation of the soil before using trenchless techniques*.
+- [b-BS EN 1340:2003] BS EN 1340:2003, *Concrete kerb units. Requirements and test methods*.
+- [b-Cottino] Cottino, E., Di Buono, N. (2009), *A Complete enabling solution for FTTx network infrastructure*, IWCS Proceedings.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.20-199610-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg b/marked/L/T-REC-L.20-199610-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3a58f68885c03bc2fb95bb409d68f7f55947475f
--- /dev/null
+++ b/marked/L/T-REC-L.20-199610-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:97adcbdebb3326a1af9817c0266d6c1cef088a8f97dc377b1e5fd01e721d14f7
+size 8269
diff --git a/marked/L/T-REC-L.20-199610-I_PDF-E/raw.md b/marked/L/T-REC-L.20-199610-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..58d57bd2505489ec4aaa949b70d7ff2ad549c368
--- /dev/null
+++ b/marked/L/T-REC-L.20-199610-I_PDF-E/raw.md
@@ -0,0 +1,130 @@
+
+
+
+
+ITU logo: A globe with a lightning bolt and the letters ITU.
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.20**
+
+(10/96)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS
+OF OUTSIDE PLANT
+
+---
+
+**Creation of a fire security code for
+telecommunication facilities**
+
+ITU-T Recommendation L.20
+
+(Previously CCITT Recommendation)
+
+---
+
+# ITU-T L-SERIES RECOMMENDATIONS **CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+*For further details, please refer to ITU-T List of Recommendations.*
+
+## FOREWORD
+
+The ITU-T (Telecommunication Standardization Sector) is a permanent organ of the International Telecommunication Union (ITU). The ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Conference (WTSC), which meets every four years, establishes the topics for study by the ITU-T Study Groups which, in their turn, produce Recommendations on these topics.
+
+The approval of Recommendations by the Members of the ITU-T is covered by the procedure laid down in WTSC Resolution No. 1 (Helsinki, March 1-12, 1993).
+
+ITU-T Recommendation L.20, was prepared by ITU-T Study Group 6 (1993-1996) and was approved by the WTSC (Geneva, October 9-18, 1996).
+
+---
+
+## NOTES
+
+1. In this Recommendation, the expression “Administration” is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+2. The status of annexes and appendices attached to the Series L Recommendations should be interpreted as follows:
+ - an *annex* to a Recommendation forms an integral part of the Recommendation;
+ - an *appendix* to a Recommendation does not form part of the Recommendation and only provides some complementary explanation or information specific to that Recommendation.
+
+
+
+## **CREATION OF A FIRE SECURITY CODE FOR TELECOMMUNICATION FACILITIES**
+
+*(Geneva, 1996)*
+
+## **Introduction**
+
+In most countries, there are both national and provincial as well as other fire regulation codes related to buildings for the prevention of the spread of fire.
+
+Some companies operating in countries where the fire regulation codes may or may not apply do not have a specific code for their internal use in order to unify, optimize and adjust their needs to provide adequate fire protection measures. This situation will increase the work of the management project group since it will be necessary to compile and evaluate national and international fire regulation codes for the design and conditioning of buildings destined to house telecommunication equipment and facilities and for the training of personnel.
+
+The adoption of adequate fire prevention measures can lessen the risk to life and reduce the chances of a serious disruption to the telecommunication network.
+
+The fire department of a civil administration needs information on any telecommunication building concerning access, local fire fighting facilities, emergency power supplies, water supplies in tall buildings, where to disconnect the public power supplies, the presence of hazardous materials and the importance of minimizing water damage to telecommunication equipment.
+
+### **It is recommended**
+
+For existing buildings and the design and construction of new buildings, housing telecommunications installations administrations should create an internal fire security code, according to the anticipated specific use of each building, containing the minimum guidelines for fire safety and protection against fire.
+
+The code should be made starting with an analysis of each country's national, provincial or other fire regulation codes.
+
+The basic structure will be the following:
+
+- documentation;
+- basic design guidelines to be put into practice for building construction;
+- basic design guidelines to be put into practice for the construction and installation of equipment;
+- measures to be put into practice for reducing the time between ignition and effective fire fighting in buildings;
+- fire detection and alarm systems;
+- fixed fire-extinguishing systems;
+- portable fire extinguishers;
+- emergency lighting;
+- fire safety signs;
+- organization and training of personnel in fire instruction and drills for evacuation and fire fighting in the case of a fire;
+- disaster recovery plan covering the hazard assessment of deposits produced by a fire together with the precautions necessary for their safe removal;
+- temporary service for emergency and other essential services;
+
+- agreement with the civil administration fire department for a training plan for fire fighting, to be implemented in each building, containing the steps to be followed for fire extinction and of the resources to be used;
+- fire statistic reports (for example, performance of different materials in the case of a fire).
+
+The design of new buildings and the adaptation of existing buildings should comply with the following conditions:
+
+- to rapidly detect any fire should it break out;
+- to minimize fire spread in each building and to avoid the spread of fire from one building to another;
+- to provide safe exits for the easy evacuation of all personnel in case of fire;
+- to provide easy access for fire fighting and fire extinction;
+- to provide fire instruction and carry out evacuation exercises so that all personnel know what to do in case of fire.
+
+## ITU-T RECOMMENDATIONS SERIES
+
+- Series A Organization of the work of the ITU-T
+- Series B Means of expression: definitions, symbols, classification
+- Series C General telecommunication statistics
+- Series D General tariff principles
+- Series E Overall network operation, telephone service, service operation and human factors
+- Series F Non-telephone telecommunication services
+- Series G Transmission systems and media, digital systems and networks
+- Series H Audiovisual and multimedia systems
+- Series I Integrated services digital network
+- Series J Transmission of television, sound programme and other multimedia signals
+- Series K Protection against interference
+- Series L Construction, installation and protection of cables and other elements of outside plant**
+- Series M Maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits
+- Series N Maintenance: international sound programme and television transmission circuits
+- Series O Specifications of measuring equipment
+- Series P Telephone transmission quality, telephone installations, local line networks
+- Series Q Switching and signalling
+- Series R Telegraph transmission
+- Series S Telegraph services terminal equipment
+- Series T Terminals for telematic services
+- Series U Telegraph switching
+- Series V Data communication over the telephone network
+- Series X Data networks and open system communication
+- Series Z Programming languages
\ No newline at end of file
diff --git a/marked/L/T-REC-L.201-202105-I_PDF-E/raw.md b/marked/L/T-REC-L.201-202105-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..8995c0934d95f943618714684dde2cf0ac3cb981
--- /dev/null
+++ b/marked/L/T-REC-L.201-202105-I_PDF-E/raw.md
@@ -0,0 +1,1114 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.201**
+
+(05/2021)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+Optical infrastructures – Infrastructure including node
+elements (except cables)
+
+# --- **Performance requirements for passive optical nodes: Sealed Closures for Outdoor Environments**
+
+Recommendation ITU-T L.201
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+## ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
+
+| | |
+|---------------------------------------------------------------|--------------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000–L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200–L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300–L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400–L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500–L.1599 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700–L.1799 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.201
+
+# Performance requirements for passive optical nodes: Sealed closures for outdoor environments
+
+## Summary
+
+Recommendation ITU-T L.201 refers to passive optical nodes in outdoor environments. It deals with the design of the closure housing as well as the fibre organizer or fibre management system, taking into account mechanical and environmental characteristics as well as the characteristics of the optical fibre organizer.
+
+The following new elements have been added in this revision:
+
+- A new clause 6.3 on closure materials with detailed test requirements for UV-light exposure and the fungal resistance of polymer materials and a material test requirement for the ageing of polymer materials by humidity;
+- A new clause 6.5 on cable attachment and termination with recommendations for the electrical grounding of the metallic elements of the cables;
+- A test programme for the performance evaluation of sealed optical closures in the outdoor ground level (OG) environment.
+
+The following changes were made to harmonize the performance tests with [IEC 61753-1]:
+
+- Sealing tests are done with 20 kPa overpressure for OG and outdoor above ground (OA) closures.
+- Pass-fail criteria of pressure loss during test have been added to mechanical sealing tests for OG and OA closures.
+- Reduced loads for the cable axial tension test for small diameter cables and microduct tubes.
+- Reduced loads for the cable axial compression test for small diameter cables.
+- The duration of the cycles in cable torsion and cable bending test have been added.
+- The location for impact test has been added for rectangular shaped closures.
+- The free fall test has been removed (it has been replaced by a more reproduceable shock test).
+- In the assembly and disassembly test the duration is reduced to 5 cycles.
+- Resistance to solvents and contaminating fluids: immersion in diesel with duration of 1 h and 24 h drying time and added immersion in petroleum jelly for 5 days has been added. Kerosene immersion has been removed.
+- The duration of the change of temperature has been reduced to 12 cycles.
+- Water immersion test at 1 m for 7 days for OG closures has been added.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|------------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.13 | 1992-07-31 | | 11.1002/1000/1417 |
+| 2.0 | ITU-T L.201/L.13 | 2003-04-11 | 6 | 11.1002/1000/6135 |
+| 3.0 | ITU-T L.201 | 2021-05-29 | 15 | 11.1002/1000/14636 |
+
+## Keywords
+
+Fibre management system, organizer, outside plant, passive optical nodes, sealed closures.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2021
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-------------------------------------------------------------------------------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 3 |
+| 3.1 Terms defined elsewhere ..... | 3 |
+| 3.2 Terms defined in this Recommendation..... | 3 |
+| 4 Abbreviations and acronyms ..... | 3 |
+| 5 Conventions ..... | 4 |
+| 6 Design characteristics of optical closures..... | 4 |
+| 6.1 General requirements..... | 4 |
+| 6.2 Design of the closure housing ..... | 4 |
+| 6.3 Closure materials ..... | 4 |
+| 6.4 Design of the optical fibre organizer (fibre management system) ..... | 5 |
+| 6 Performance evaluation test programme ..... | 6 |
+| 7 Sample preparation ..... | 7 |
+| Annex A – Performance evaluation criteria..... | 8 |
+| A.1 Sealing evaluation ..... | 8 |
+| A.2 Optical performance evaluation ..... | 8 |
+| Annex B – Performance test programme for outdoor subterranean or underground (OS) closures, ground level (OG) closures and above ground (OA) closures ..... | 10 |
+| B.1 Sealing evaluation ..... | 10 |
+| B.2 Optical performance evaluation ..... | 14 |
+| Appendix I – Product characterization checklist ..... | 17 |
+| Appendix II – Ukrainian experience..... | 20 |
+| II.1 Introduction ..... | 20 |
+| II.2 Dimension and optical characteristics ..... | 20 |
+| II.3 Environmental characteristics ..... | 20 |
+| II.4 Mechanical characteristics..... | 22 |
+| II.5 Field condition tests..... | 23 |
+| Bibliography..... | 24 |
+
+## Introduction
+
+A node occurs at each opening or end of a cable sheath. When an optical node resides in an outdoor environment, it is generally contained in a sealed enclosure. This is commonly referred to as an optical closure, optical cable joint or optical sheath joint. In this Recommendation the term "optical closure" will be used.
+
+An optical closure comprises a mechanical structure (closure housing) that is attached to the ends of the sheaths joined and a means (organizer) for containing and protecting the fibres and passive optical devices. The optical closure will:
+
+- Restore the integrity of the sheath, including mechanical continuity of strength members when required
+- Protect the fibres, fibre joints and optical devices from the environment in all types of outdoor plant (aerial, direct buried, in ducts and underwater).
+- Provide for the organization of the fibre joints, passive devices and the storage of fibre overlength.
+- Provide electrical bonding and grounding of the metal parts of the sheath and strength members where required. The method of achieving electrical continuity will vary with the type of cable sheath and the type and location of the strength members. Further information is given in [ITU-T K.11], [ITU-T K.47], [IEC 62368-1] and the ITU-T Manual "Protection of telecommunication lines and equipment against lightning discharges" [b-ITU-T Manual].
+
+This Recommendation provides the means for characterizing and evaluating the performance of optical closures according to the principles of [ITU-T L.200]. This includes both the mechanical integrity and the optical stability of the product, simulating the effect of environmental factors, as well as interventions related to network maintenance. It contains a basic test programme for optical closures which is globally applicable. Additional requirements can be agreed between customer and supplier to reflect local or special conditions. All functions and features that a product may contain should be reflected in the mix of test samples that are subjected to the test programme.
+
+# Performance requirements for passive optical nodes: Sealed closures for outdoor environments
+
+# 1 Scope
+
+This Recommendation:
+
+- Refers to passive optical nodes in outdoor environments;
+- Deals with the design of the closure housing as well as the fibre organizer;
+- Deals with the mechanical and environmental characteristics of the optical closure;
+- Deals with the characteristics of the optical fibre organizers;
+- Provides a test programme for the performance evaluation of sealed optical closures in three basic environments: outdoor subterranean or underground (OS), outdoor ground level (OG) and outdoor above ground (OA);
+- Provides a simulation of the effect of interventions related to network maintenance;
+- Contains a checklist for a systematic product characterization according to [ITU-T L.200];
+- Contains a list of additional requirements to reflect special environments (e.g., tunnels) and local conditions.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T G.652] Recommendation ITU-T G.652 (2016), *Characteristics of a Single-Mode Optical Fibre and Cable*.
+- [ITU-T G.657] Recommendation ITU-T G.657 (2016), *Characteristics of a Bending-Loss Insensitive Single-Mode Optical Fibre and Cable*.
+- [ITU-T K.11] Recommendation ITU-T K.11 (2009), *Principles of Protection Against Overvoltages and Overcurrents*.
+- [ITU-T K.47] Recommendation ITU-T K.47 (2012), *Protection of Telecommunication Lines Against Direct Lightning Flashes*.
+- [ITU-T L.200] Recommendation ITU-T L.200/L.51 (2003), *Passive Node Elements for Fibre Optic Networks – General Principles and Definitions for Characterization and Performance Evaluation*.
+- [IEC 60068-2-10] IEC 60068-2-10 (2005), *Environmental testing – Part 2: Tests - Test J and guidance: Mould growth*.
+- [IEC 60529] IEC 60529 (2013), *Degrees of protection provided by enclosures (IP Code)*.
+- [IEC 61300-2-1] IEC 61300-2-1 (2009), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)*.
+
+- [IEC 61300-2-4] IEC 61300-2-4 (2019), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-4: Tests – Fibre/cable retention.*
+- [IEC 61300-2-5] IEC 61300-2-5 (2009), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-5: Tests – Torsion.*
+- [IEC 61300-2-9] IEC 61300-2-9 (2017), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-9: Tests – Shock.*
+- [IEC 61300-2-10] IEC 61300-2-10 (2021), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-10: Tests – Crush resistance.*
+- [IEC 61300-2-11] IEC 61300-2-11 (2012), *Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-11: Tests – Axial compression.*
+- [IEC 61300-2-12] IEC 61300-2-12 (2009), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-12: Tests – Impact.*
+- [IEC 61300-2-19] IEC 61300-2-19 (2012), *Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-19: Tests - Damp heat (steady state).*
+- [IEC 61300-2-22] IEC 61300-2-22 (2007), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-22: Tests – Change of temperature.*
+- [IEC 61300-2-23] IEC 61300-2-23 (2010), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-23: Tests – Sealing for non-pressurized closures of fibre optic devices.*
+- [IEC 61300-2-26] IEC 61300-2-26 (2007), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-26: Tests – Salt mist.*
+- [IEC 61300-2-33] IEC 61300-2-33 (2012), *Fibre optic interconnecting devices and passive components – Basic test –and measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures.*
+- [IEC 61300-2-34] IEC 61300-2-34 (2009), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-34: Tests – Resistance to solvents and contaminating fluids of interconnecting components and closures.*
+- [IEC 61300-2-37] IEC 61300-2-37 (2016), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-37: Tests – Cable bending for closures.*
+- [IEC 61300-2-38] IEC 61300-2-38 (2006), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-38: Tests – Sealing for pressurized fibre optic closures.*
+
+- [IEC 61300-3-1] IEC 61300-3-1 (2005), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-1: Examinations and measurements – Visual examination.*
+- [IEC 61300-3-3] IEC 61300-3-3 (2009), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of changes in attenuation and return loss (multiple paths).*
+- [IEC 61300-3-28] IEC 61300-3-28 (2012), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-28: Examinations and measurements – Transient loss.*
+- [IEC 61753-1] IEC 61753-1 (2018), *Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance.*
+- [IEC 61756-1] IEC 61756-1 (2019), *Fibre optic interconnecting devices and passive components – Interface standard for fibre management systems – Part 1: General and guidance.*
+- [IEC 62368-1] IEC 62368-1 (2018), *Audio/video, information and communication technology equipment – Part 1: Safety requirements.*
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 closure housing:** Closure housing refers only to the sealed container or box and does not include the organizer system. Its main functions are: providing sealing to the cables, mechanical attachment of the cable and protecting its content.
+
+**3.2.2 optical closure:** The term "optical closure" refers to a sealed sheath joint, including the optical fibre organizer or fibre management system.
+
+**3.2.3 optical fibre organizer (fibre management system):** In a node, the optical fibres are to be properly managed and guided from where a cable or pigtail enters the node until it leaves again. The organizer system comprises all the means and features that are intended to guide and store fibres and passive devices inside a node, at any location where they are not protected by the cable sheath.
+
+## 4 Abbreviations and acronyms
+
+For the definitions of terms used in this Recommendation, see [ITU-T L.200].
+
+| | |
+|------|-------------------------------------|
+| ME | Multiple Element (mass storage) |
+| OA | Outdoor Above Ground |
+| OG | Outdoor Ground level |
+| OPGW | Optical Power Ground Wire |
+| OS | Outdoor Subterranean or underground |
+| SC | Single Circuit |
+| SE | Single Element |
+
+SF Single Fibre
+
+SR Single Ribbon
+
+## **5 Conventions**
+
+None.
+
+# **6 Design characteristics of optical closures**
+
+### **6.1 General requirements**
+
+Each optical closure must comply to the general requirements as listed in clause 8 of [ITU-T L.200].
+
+### **6.2 Design of the closure housing**
+
+Closure housing designs employ either cold or hot systems depending on the sealing methods used. Cold processes do not require heat, whereas hot processes do. Mastic, tapes, grommets, o-rings, cured rubber shapes, pastes, potting compounds, rubber gels and (cold) adhesives are cold processes. Thermoshrinkable materials, hotmelts and polyethylene injection welding are the primary hot processes. The heat source may be electrical resistance heating, infrared heating, hot air or a gas flame. Regardless of which of these processes is used, the following should be considered:
+
+- The materials used for making the cable joint should be compatible with each other, with the materials of the sheath and with other materials and solvents normally used in the outside plant.
+- A design may allow for jointing together two or more cable ends. The cables entering the closure may be of differing sizes and/or types.
+- A design should allow for jointing together at least one pair of cables which are not at the end of a cable, i.e., without cutting all the fibres between both cable ends (this application is also known as "external node", "midspan closure" or "balloon splice").
+- It is desirable that closures can be re-opened when necessary and remade without interruptions to working circuits.
+- A single design, which may be used for all of the above applications and in all outdoor environments.
+- If a design is limited to certain applications and environments in the network, any limitations should be clearly indicated to the user; the detailed characterization of features and compatibility of a closure can be done using the checklist in Appendix I.
+- If joint sealing encapsulant is used, information is required for adjustments in setting time due to variations in ambient temperature and humidity; the use of encapsulant is not recommended for re-enterable closures.
+- If a heat source is required to seal the closure and/or closure to the sheath, a suitable heat source (gas flame or electrical power) needs to be available at the jointing points. Consideration should be given to the control of the heat source to protect personnel and prevent damage to the closure or cable.
+
+## **6.3 Closure materials**
+
+All materials that are likely to come in contact with personnel should meet appropriate local health and safety regulations. Closure materials should be compatible with each other and with the materials of the cables and/or microducts. All components of the closure should be resistant to solvents and degreasing agents that are typically used to clean and degrease fibres and cables.
+
+The materials used in the closures should remain functional when exposed to outside plant environments:
+
+- All polymer materials should be sufficiently resistant to fungi. The fungal resistance test is done according to [IEC 60068-2-10] variant 1, severity 1. The effect of fungal growth should be determined by measuring a suitable property (e.g., tensile strength and elongation at yield) both before and after the exposure of the material slabs. The average change in the mechanical characteristics of the tested material slabs should be less than 20%.
+- The polymer materials that will be exposed to solar radiation should be UV resistant. The UV test is done according to [b-ISO 4892-3], lamp type 1A (UVA-340), cycle 1, duration 2160 h. The effect of UV light should be determined by measuring a suitable property (e.g., tensile strength and elongation at yield) both before and after the exposure of the material slabs. The average change in the mechanical characteristics of the tested material slabs should be less than 20%.
+- All polymer materials should be resistant to high humidity. A damp heat (steady state) test according to [IEC 61300-2-19] should be done at a high temperature and high humidity as long as no phase transitions in the material occur. The following conditions and durations could be used:
+ - +75°C/95%RH for 2 000 h;
+ - +85°C/95%RH for 1 000 h;
+ - +95°C/95%RH for 500 h.
+
+Higher test temperatures with shorter test duration are allowed when no phase transition occurs in the material. The ageing effect of humidity should be determined by measuring a suitable property (e.g., tensile strength and elongation at yield) both before and after the exposure of the material slabs. The average change in the mechanical characteristics of the tested material slabs should be less than 20%.
+
+- All metal parts should be resistant to corrosive effects. The effects of corrosion are tested on the complete closure or on representative test samples according to the salt fog test method described in clause B.1.10. No signs of beginning corrosion should be visible. A colour change caused by passivation is allowed.
+
+### **6.4 Design of the optical fibre organizer (fibre management system)**
+
+Fibre organizers are an integral part of an optical closure. The organizers are comprised of one or more sheets or trays that have means for routeing and holding fibre joints and fibre overlength in an orderly manner and should minimize fibre strain.
+
+Organizer compatibility and features can be listed by using the checklist in Appendix I. The desired optical stability type can be selected according to [ITU-T L.200].
+
+#### **6.4.1 Characteristics of the optical fibre organizer (fibre management system)**
+
+The function of an optical fibre organizer is:
+
+- To provide means for routeing, storing and protecting fibre joints or other passive devices in a predetermined order, from one cable sheath end to another;
+- To separate circuits up to a certain level as defined in [ITU-T L.200]; the number of fibre joints in one organizer may vary according to the size and shape of the fibre joint and the number of fibres in a cable subunit;
+- To ensure that the fibre bend radius should not be less than the recommended radius for the application specified by [IEC 61756-1] or [b-ITU-T G Sup59];
+- To provide easy identification and access to any stored fibre joint for remaking the joint;
+
+- To separate fibre circuits up to the appropriate separation level; this will limit the risk of interruption of traffic to those fibres that belong to the same group of circuits (see [ITU-T L.200]: single circuit (SC), single element (SE), single fibre (SF), single ribbon (SR), multiple element (ME));
+- To provide a means for storing the fibre overlenth required for jointing and for possible rejoining in the future.
+
+The materials used for making the organizer should be compatible with the other materials in the cable joint and the degreasing agents as recommended in the installation instructions.
+
+#### 6.4.2 Configurations of the optical fibre organizers (fibre management systems)
+
+The trays or sheets of an organizer may be configured in one of the following ways:
+
+- Lateral sliding from a frame – similar to removing a book from a shelf;
+- Rotation about a hinge – similar to turning a page in a book;
+- Lifting from a stack – similar to lifting a book from a stack; or
+- Unrolling – similar to locating a page on a scroll.
+
+All movements of the organizer parts should proceed in a predetermined way in order to prevent optical losses or interruption of traffic due to organizer manipulations.
+
+### 6.5 Cable attachment and termination
+
+The following characteristics for cable attachment and termination should be considered:
+
+- Allowing attachment of all cables entering the closure. The cables may be of different sizes and/or types.
+- When applicable, providing a good bonding and grounding of metallic elements of cables. The method of achieving electrical continuity can vary with the type of cable sheath and the type and location of the strength members. Further information is given in [ITU-T K.11], [ITU-T K.47] and [IEC 62368-1].
+- The addition or removal of cables should not result in interruption of service on other cables.
+
+# 7 Performance evaluation test programme
+
+The complete test programme for a passive optical closure consists of:
+
+- A basic test programme for the applicable environment (see Annexes A and B);
+- A number of additional requirements according to local standards when necessary (see [ITU-T L.200] and the checklist in Appendix I).
+
+For specific products, alternative test conditions to those given in Annex B may be agreed between customer and supplier.
+
+Tests are executed according to IEC 61300-2 test methods where available.
+
+The performance test programme of a passive optical closure should:
+
+- Evaluate the product for two groups of criteria: mechanical integrity and optical stability (see Annex A);
+- Simulate the effects of exposure to:
+ - The environment in which it will be installed;
+ - An intervention at the node.
+- Simulate installation conditions at temperatures between $-5^{\circ}\text{C}$ and $+45^{\circ}\text{C}$ ;
+- Simulate closure and cable handling at temperatures between $-15^{\circ}\text{C}$ and $+45^{\circ}\text{C}$ ;
+- Evaluate all available features of the product.
+
+When an optical closure is suitable for all environments, OA, OG and OS, it should pass whichever conditions of the three environments that are the most severe. As an alternative, the tests that are different for each of these environments may be duplicated at both settings.
+
+Two types of optical stability can be selected (see clause 6.2.1 in [ITU-T L.200]); for products that may be subject to an intervention while the network remains live, dynamic optical stability is recommended.
+
+# **8 Sample preparation**
+
+A representative number of test samples is to be prepared, taking into account the following parameters:
+
+- All product features and compatibility (see checklist in Appendix I);
+- Applicable sizes of cables;
+- Sealing test samples should be installed at $-5^{\circ}\text{C}$ , room temperature and $+45^{\circ}\text{C}$ ;
+- For sealing evaluation, a fresh sample should be prepared for each different test; if a failure occurs when consecutive testing is applied on the same sample, the last test may be repeated on a fresh sample;
+- For the optical performance evaluation, the closure should be installed with sufficient long cables of the relevant fibre type for which the organizer system is designed.
+
+Appendix I in [ITU-T L.200] illustrates how optical samples can be prepared. Due to their complexity, consecutive testing on the same sample is the most practical approach.
+
+## Annex A
+
+### Performance evaluation criteria
+
+(This annex forms an integral part of this Recommendation.)
+
+### A.1 Sealing evaluation
+
+It should be ensured that the performance evaluation criteria are met during or after tests in Annex B.
+
+#### A.1.1 Pressure loss during the test
+
+International standard: [IEC 61300-2-38] Method B.
+
+Conditions: Internal pressure: (OS) $(40 \pm 2)$ kPa; (see Note b4, Annex B);
+(OG and OA) $(20 \pm 2)$ kPa;
+Temperature: at test temperature;
+Measurement before and after the test should be done within 12 h.
+
+Requirement: Difference in pressure before and after the test $\leq 2$ kPa measured under the same atmospheric test conditions.
+
+#### A.1.2 Tightness after test
+
+International standard: [IEC 61300-2-38] Method A.
+
+Conditions: Internal pressure: (OS) $(40 \pm 2)$ kPa; (see Note b4, Annex B);
+(OG and OA) $(20 \pm 2)$ kPa;
+Test temperature: $(+23 \pm 5)^\circ\text{C}$ ;
+Test time: 15 minutes;
+Depth: Just below water surface.
+
+Requirement: No bubbles indicating a leakage should be observed during the test.
+
+#### A.1.3 Visual appearance
+
+International standard: [IEC 61300-3-1].
+
+Conditions: Examination of product with the naked eye.
+
+Requirement: No defects which would affect product performance.
+
+### A.2 Optical performance evaluation
+
+NOTE a1 – All optical losses indicated are referenced to the initial optical signal at the start of the test.
+
+NOTE a2 – An "incoming fibre" is defined as a part of an optical circuit containing the fibre entering the product, spliced to a fibre leaving the product. One optical circuit can contain many "incoming fibres". Light will sequentially flow through all the "incoming fibres".
+
+NOTE a3 – In general the fibre type used for building the test samples is ITU-T G.652.D fibre with nominal mode field diameter between 9.0 $\mu\text{m}$ and 9.2 $\mu\text{m}$ . When closures are qualified with these ITU-T G.652.D fibres, they are automatically qualified for use with other ITU-T G.652.D and ITU-T G.657 fibres. If the organizer system is designed for bending-loss insensitive single-mode fibres [ITU-T G.657], the relevant fibre type needs to be used in the optical test sample.
+
+#### **A.2.1 Change in attenuation (change in insertion loss) (static optical stability)**
+
+International standard: [IEC 61300-3-3] Method 1.
+
+Conditions: Source wavelength: 1 310 nm, 1 550 nm or 1625 nm (select the highest applicable wavelength).
+
+Requirement: $\Delta IL \leq 0.2$ dB (1 310 nm/1 550 nm) per incoming fibre during the test (excursion loss);
+ $\Delta IL \leq 0.5$ dB (1 625 nm) per incoming fibre during the test (excursion loss);
+ $\Delta IL \leq 0.1$ dB (1 310 nm/1 550 nm/1 625 nm) per incoming fibre after the test (residual loss).
+
+#### **A.2.2 Transient loss (dynamic optical stability)**
+
+International standard: [IEC 61300-3-28].
+
+Conditions: Source wavelength: 1 310 nm, 1 550 nm or 1 625 nm (select the highest applicable wavelength) unpolarized;
+
+Requirement: $\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm) during the test measured in the live circuit (transient loss);
+ $\Delta IL \leq 1.0$ dB (1 625 nm) during the test measured in the live circuit (transient loss);
+ $\Delta IL \leq 0.1$ dB (1 310 nm/1 550 nm/1 625 nm) after the test in the live circuit (residual loss).
+
+## Annex B
+
+### Performance test programme for outdoor subterranean or underground (OS) closures, ground level (OG) closures and above ground (OA) closures
+
+(This annex forms an integral part of this Recommendation.)
+
+For this annex consider the following notes:
+
+NOTE b1 – D is the outer diameter of the cable in mm.
+
+NOTE b2 – All testing is performed at room temperature unless otherwise stated.
+
+NOTE b3 – Test settings are applicable for environments OA, OG and OS unless specifically marked otherwise.
+
+NOTE b4 – For OS products used in pressurized networks, all testing should be executed at $98 \pm 9.8$ kPa instead of 40 kPa.
+
+NOTE b5 – For in-line closures that are installed without cable slack, higher axial tensile loads may be necessary.
+
+NOTE b6 – For cables with a very rigid construction (e.g., slotted core cables, armoured cables), the clamping distance may need to be increased to 1 000 mm.
+
+NOTE b7 – Temperature ranges for change of temperature tests are typical values. Adaptations to specific local conditions can be agreed between customer and supplier.
+
+NOTE b8 – The need for static or dynamic optical stability is to be agreed between customer and supplier. When no degradation in transmission is allowed during handling or reconfiguration of the closure, the dynamic optical stability criterion is used. The appropriate performance criteria are to be selected accordingly in the test programme of B.2.
+
+### B.1 Sealing evaluation
+
+#### B.1.1 Cable axial tension
+
+International standard: [IEC 61300-2-4]
+
+Conditions: Load per cable (N): $20 \times D$ (mm) with maximum of 1 000 N for cables with diameter $D > 7$ mm (Note b1 and b5);
+ $10 \times D$ for cables with diameter $D \leq 7$ mm;
+10 N for tubes and cables without strength member;
+
+Load application: 400 mm from the end of the seal;
+
+Test pressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OG and OA) $(20 \pm 2)$ kPa;
+
+Test temperatures: $(-15 \pm 2)^\circ\text{C}$ and $(+45 \pm 2)^\circ\text{C}$ ;
+
+Test time: 1 h per cable.
+
+Performance criteria: Tightness after test; Pressure loss during test; Visual appearance.
+
+#### **B.1.2 Cable flexure**
+
+International standard: [IEC 61300-2-37]
+
+Conditions: Force: 30° bending or max. 500 N;
+Force application: 400 mm from end of the seal (Note b6);
+Test pressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OG and OA) $(20 \pm 2)$ kPa;
+Test temperatures: $(-15 \pm 2)^\circ\text{C}$ and $(+45 \pm 2)^\circ\text{C}$ ;
+Number of cycles: 5 per cable.
+
+Performance criteria: Tightness after test; Pressure loss during test; Visual appearance.
+
+#### **B.1.3 Cable torsion**
+
+International standard: [IEC 61300-2-5]
+
+Conditions: Torque: maximum rotation 90° / maximum 50 Nm;
+Torque application: 400 mm from the end of the seal (Note b6);
+Test overpressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OG and OA) $(20 \pm 2)$ kPa;
+Test temperatures: $(-15 \pm 2)^\circ\text{C}$ and $(+45 \pm 2)^\circ\text{C}$ ;
+Number of cycles: 5 per cable.
+
+Performance criteria: Tightness after test; Pressure loss during test; Visual appearance.
+
+#### **B.1.4 Impact**
+
+International standard: [IEC 61300-2-12] Method B
+
+Conditions: Impact tool: Steel ball; Weight: 1 kg;
+Drop height: (OS) 2 m;
+(OG and OA) 1 m;
+Test overpressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OG and OA) $(20 \pm 2)$ kPa;
+Test temperatures: $(-15 \pm 2)^\circ\text{C}$ and $(+45 \pm 2)^\circ\text{C}$ ;
+Location: at the centre of the closure at 0°, 90°, 180°, 270° around the longitudinal axis. For rectangular shaped closures the impact location should be at the centre of the largest flat surface;
+Number of impacts: 1 per location.
+
+Performance criteria: Tightness after test; Pressure loss during test; Visual appearance.
+
+#### **B.1.5 Static load (crush test) (OG and OS only)**
+
+International standard: [IEC 61300-2-10]
+
+Conditions: Load: 1 000 N; Application with circular surface of 25 cm2 ;
+Test overpressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OG) $(20 \pm 2)$ kPa;
+Test temperatures: $(-15 \pm 2)^\circ\text{C}$ and $(+45 \pm 2)^\circ\text{C}$ ;
+Location: at the centre of the closure at 0° and 90° around the longitudinal axis;
+Duration: 10 minutes.
+
+Performance criteria: Tightness after test; Pressure loss during test; Visual appearance.
+
+#### **B.1.6 Vibration (sealing)**
+
+International standard: [IEC 61300-2-1]
+
+Conditions: Frequency: 10 Hz; Cycle: Sinusoidal; Amplitude: at least 3 mm (= 6 mm peak-to-peak);
+Test overpressure: (OS) $(40 \pm 2)$ kPa regulated;
+(OG and OA) $(20 \pm 2)$ kPa regulated;
+Cable clamping: 500 mm from end of the seal;
+Duration: at least 1 000 000 cycles ~28 h.
+
+Performance criteria: Tightness after test; Visual appearance.
+
+#### **B.1.7 Waterhead (OS and OG only)**
+
+International standard: [IEC 61300-2-23]
+
+Conditions: Water column height:
+(OS) 5 m (or an equivalent external water pressure of 50 kPa);
+(OG) 1 m (or an equivalent external water pressure of 10 kPa);
+Wetting agent: none;
+Test pressure: 0 kPa overpressure, sealed off at room temperature;
+Duration: 7 days.
+
+Performance criteria: Visual Appearance: No water ingress.
+
+#### **B.1.8 Resistance to aggressive media**
+
+International standard: [IEC 61300-2-34]
+
+Conditions: Submersion in: (OA, OG and OS) HCl at pH 2;
+(OA, OG and OS) NaOH at pH 12;
+(OG and OS) Petroleum jelly;
+(OG and OS) Diesel fuel for cars: [b-EN 590];
+Test pressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OA and OG) $(20 \pm 2)$ kPa;
+Duration: 1 h for diesel, 5 days for other detergents.
+Drying time: 24 h for diesel at room temperature, none for other detergents;
+
+Performance criteria: Tightness after test; Visual appearance.
+
+#### **B.1.9 Resistance to detergents (stress cracking) (OS and OG only)**
+
+International standard: [IEC 61300-2-34]
+
+Conditions: Submersion in 10% Nonyl Phenol Ethoxylate solution at 50°C;
+Test pressure: (OS) $(40 \pm 2)$ kPa (Note b4);
+(OA and OG) $(20 \pm 2)$ kPa;
+Drying time: none;
+Duration: 5 days.
+
+Performance criteria: Tightness after test; Visual appearance: No visible cracking.
+
+#### **B.1.10 Resistance to corrosion (salt fog)**
+
+International standard: [IEC 61300-2-26]
+
+Conditions: Exposure to a salt mist of 5% NaCl in water; pH between 6.5 and 7.2
+Test overpressure: 0 kPa overpressure, sealed off at room temperature;
+Test temperature: $(+35 \pm 2)^\circ\text{C}$ ;
+Duration: 5 days.
+
+Performance criteria: Tightness after test; Visual appearance: No signs or evidence of corrosion. A colour change caused by passivation is allowed.
+
+#### **B.1.11 Change of temperature (OS)**
+
+International standard: [IEC 61300-2-22]
+
+Conditions: Lowest/Highest temperature: $(-30/+60 \pm 2)^\circ\text{C}$ ;
+Humidity: uncontrolled (Note b7);
+Dwell time: 4 h;
+Transition time: 2 h;
+Internal overpressure: $(40 \pm 2)$ kPa regulated (Note b4);
+Number of cycles: 12.
+
+Performance criteria: Tightness; Visual appearance.
+
+#### **B.1.12 Change of temperature (OA and OG)**
+
+International standard: [IEC 61300-2-22]
+
+Conditions: Lowest/highest temperature: $(-40/+65 \pm 2)^\circ\text{C}$ ;
+Humidity: uncontrolled (Note b7);
+Dwell time: 4 h;
+Transition time: 2 h;
+Internal overpressure: $(20 \pm 2)$ kPa regulated;
+Number of cycles: 12.
+
+Performance criteria: Tightness; Visual appearance.
+
+#### **B.1.13 Re-entries**
+
+International standard: [IEC 61300-2-33]
+
+Conditions: Ageing between each re-entry: at least one thermal cycle (see clauses B1.11 (OS) and B1.12 (OA and OG));
+Number of re-entries: 5.
+
+Performance criteria: Tightness after test and after each re-entry.
+
+#### **B.1.14 Cable axial compression**
+
+International standard: [IEC 61300-2-11]
+
+Conditions: Load per cable (N): Note b1
+10 N for $D < 3\text{mm}$
+20 N for $3\text{ mm} \leq D < 6\text{ mm}$
+50 N for $6\text{ mm} \leq D < 10\text{ mm}$
+100 N for $10\text{ mm} \leq D < 20\text{ mm}$
+200 N for $D \geq 20\text{ mm}$
+10 N for tubes and cables without strength member;
+Load application: At maximum twice the cable diameter measured from end of seal.
+Duration: 30 minutes per cable.
+
+Performance criteria: The cable should not move inwards more than 5 mm.
+
+### **B.2 Optical performance evaluation**
+
+Construction of optical samples according to Annex A of [ITU-T L.200].
+
+#### **B.2.1 Cable axial tension**
+
+International standard: [IEC 61300-2-4]
+
+Conditions: Load per cable (N): $20 \times D\text{ (mm)}$ (maximum 1 000 N) for cables with diameter $> 7\text{ mm}$ (Note b1 and b5);
+ $10 \times D\text{ (mm)}$ for cables with diameter $\leq 7\text{ mm}$ ;
+10 N for tubes and cables without strength member;
+Load application: 400 mm from end of the seal;
+Test pressure: (OS) $(40 \pm 2)\text{ kPa}$ (Note b4);
+(OG and OA) $(20 \pm 2)\text{ kPa}$ ;
+Test temperatures: $(+23 \pm 5)^\circ\text{C}$ ;
+Test time: 1 h per cable.
+
+Performance criteria: Static: Change in attenuation (change in insertion loss) – residual loss;
+Dynamic: Transient loss.
+
+#### **B.2.2 Cable flexure**
+
+International standard: [IEC 61300-2-37]
+
+Conditions: Bending angle: $-30^\circ$ and $+30^\circ$ bending, maximum force 500 N;
+Force application: 400 mm from end of the seal (Note b6);
+Duration at extreme position: 5 minutes
+Test temperature: $(+23 \pm 5)^\circ\text{C}$ ;
+Number of cycles: 5 per cable.
+
+Performance criteria: (Note b8) Static: Change in attenuation (change in insertion loss) – residual loss;
+Dynamic: Transient loss.
+
+#### **B.2.3 Cable torsion**
+
+| | |
+|------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| International standard: | [IEC 61300-2-5] |
+| Conditions: | Torsion angle: Rotation $+90^\circ$ and $-90^\circ$ , maximum torque 50 Nm; Torque application: 400 mm from end of the seal (Note b6); Test temperature: $(+23 \pm 5)^\circ\text{C}$ ; Number of cycles: 5 per cable. |
+| Performance criteria: (Note b8) | Static: Change in attenuation (change in insertion loss) – residual loss; Dynamic: Transient loss. |
+
+#### **B.2.4 Intervention at a node**
+
+| | |
+|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| International standard: | [IEC 61300-2-33] |
+| Conditions: | Execute all manipulations that will normally occur for this product during an intervention after initial installation. A List of typical manipulations can be found in Appendix II of [ITU-T L.200]. |
+| Performance criteria: (Note b8) | Static: Change of attenuation (change in insertion loss) – residual loss; Dynamic: Transient loss. |
+
+#### **B.2.5 Vibration (optical)**
+
+| | |
+|------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| International standard: | [IEC 61300-2-1] |
+| Conditions: | Sweep range: (5-500-50) Hz sinusoidal at 1 octave/minute; Crossover frequency: 9 Hz; – amplitude below 9 Hz: 3.5 mm; – acceleration above 9 Hz: $10 \text{ m/s}^2$ ( $\sim 1 \text{ g}$ ); Direction: 3 mutually perpendicular axes; Duration: 10 cycles/axis; Test temperature: $(+23 \pm 5)^\circ\text{C}$ . |
+| Performance criteria: (Note b8) | Visual appearance. Static: Change in attenuation (change in insertion loss) – residual loss; Dynamic: Transient loss. |
+
+#### **B.2.6 Shock**
+
+| | |
+|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| International standard: | [IEC 61300-2-9] |
+| Conditions: | Wave form: Half sine; Duration: 11 milliseconds; Acceleration: $150 \text{ m/s}^2$ ( $\sim 15 \text{ g}$ ); Direction: 3 mutually perpendicular axes; Number of shocks: 3 up and 3 down per axis; Test temperature: $(+23 \pm 5)^\circ\text{C}$ . |
+| Performance criteria: (Note b8) | Visual appearance; Static: Change in attenuation (change in insertion loss) – residual loss; Dynamic: Transient loss. |
+
+#### **B.2.7 Change of temperature (OS)**
+
+International standard: [IEC 61300-2-22]
+
+Conditions: Lowest/highest temperature: $(-30/+60 \pm 2)^\circ\text{C}$ ;
+Humidity: uncontrolled (Note b7);
+Dwell time: 4 h;
+Transition: $1^\circ\text{C}/\text{minute}$ ;
+Number of cycles: 12.
+
+Performance criteria: (Note b8) Visual appearance;
+Static/dynamic: Change in attenuation (change in insertion loss) -
+excursion loss and residual loss.
+
+#### **B.2.8 Change of temperature (OA and OG)**
+
+International standard: [IEC 61300-2-22]
+
+Conditions: Lowest/highest temperature: $(-40/+65 \pm 2)^\circ\text{C}$ ;
+Humidity: uncontrolled (Note b7);
+Dwell time: 4 h;
+Transition: $1^\circ\text{C}/\text{minute}$ ;
+Number of cycles: 12.
+
+Performance criteria: (Note b8) Visual appearance;
+Static/dynamic: Change in attenuation (change in insertion loss)
+-excursion loss and residual loss.
+
+## Appendix I
+
+### Product characterization checklist
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This checklist facilitates the systematic characterization of the features and capabilities of an optical closure. It reflects the parameters that are described in [ITU-T L.200]. It may be useful for preparation of the products' test programme as well as product description for tenders and purchasing specifications, the comparison of different or competitive products and the creation of commercial information and ordering guides.
+
+NOTE – For outdoor enclosures in general, IP protection classes are defined in [IEC 60529]. Optical closures that pass the tightness evaluation and the submersion test as described in Annexes A and B can be considered to inherently meet the IP68 requirement.
+
+**Product name:** .....
+
+**Application Environment(s)** (see clause 7.1 in [ITU-T L.200])
+
+- OA Outdoor above ground level
+- OG Outdoor ground level
+- OS Outdoor underground (subterranean)
+- E Extreme (describe differences versus a basic environmental class)
+
+**Optical functionality & compatibility** (see clause 6 in [ITU-T L.200])
+
+– **Optical stability level:**
+
+- Static
+- Dynamic (transient-free)
+
+– **Wavelength** (see clause 6.3 in [ITU-T L.200])
+
+- 1 310 nm
+- 1 550 nm
+- 1 625 nm
+- Other: .....
+
+– **Cable construction** (see clause 6.1.1 in [ITU-T L.200])
+
+- Loose buffer tube
+- Microsheath
+- Central core
+- Slotted core
+- Blown fibre
+- Break-out cable
+- Interfacility cable
+- Optical power ground wire (OPGW) cable
+- Other:.....
+
+#### – **Fibre type, fibre grouping, fibre coating** (see clause 6.1.2 in [ITU-T L.200])
+
+- Multimode
+- Single mode
+- Single fibre
+- Ribbon 4
+- R8
+- R12
+- R24
+- Other: .....
+- Primary coated (~250 µm)
+- Secondary coated (~900 µm)
+
+#### – **Passive devices** (see clause 6.1.3 in [ITU-T L.200]):
+
+- Splice type:
+ - Fusion
+ - Mechanical (brand/type):.....
+- Splice protector type:
+ - Heatshrink (min/max dimensions):.....
+ - Mechanical (brand/type) : .....
+- Connectors: specify brand/type:.....
+- Branching devices: (describe type, split ratio etc.):.....
+ - Delivered as preassembled/prefibred modules Yes No
+- Other passive devices: (describe).....
+ - Delivered as preassembled/prefibred modules Yes No
+
+#### – **Fibre storage and separation level** (see clause 6.2.2 in [ITU-T L.200])
+
+| | Circuit separation level | | | | |
+|-----------------------------------------------------|--------------------------|--------------------------|--------------------------|--------------------------|--------------------------|
+| | ME | SE | SR | SC | SF |
+| Uncut fibre (looped fibre) | | | | | |
+| Splices | | | | | |
+| Passive optical components | | | | | |
+| Other:..... | | | | | |
+
+### **Additional or special requirements and features**
+
+#### – **Storage/transport conditions** (see clause 7.2 in [ITU-T L.200])
+
+- Normal: public transport — indoor storage
+- Special handling/transport:.....
+- Special storage:.....
+
+#### – ***Additional (conditional) requirements*** (see Appendix III in [ITU-T L.200]):
+
+- | | |
+|---------------------------------------------------------------------|--------------------|
+| Bullet proof | according to:..... |
+| Earthquake resistance | according to:..... |
+| Freeze/thaw resistance | according to:..... |
+| Fire-related performance | according to:..... |
+| Fire retardancy | according to:..... |
+| Halogen-free | according to:..... |
+| Low smoke emission | according to:..... |
+| Electrical grounding and shield continuity | according to:..... |
+| Current surge | according to:..... |
+| Insulation resistance | according to:..... |
+| Contact resistance | according to:..... |
+| Rodent resistance | according to:..... |
+| Termite resistance | according to:..... |
+| Steam resistance | according to:..... |
+| Cable blocking | according to:..... |
+| Other:..... | according to:..... |
+
+## Appendix II
+
+### Ukrainian experience
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### II.1 Introduction
+
+This appendix represents the experience of Ukraine in closure performance tests for the Ukrainian conformity assessment system according to national regulations
+
+### II.2 Dimension and optical characteristics
+
+#### II.2.1 Visual inspection
+
+International standard: [b-IEC 61073-1]; IEC 61300-3-1.
+Conditions: Examination of product with naked eye.
+Acceptance criteria: No defects which will adversely affect performance.
+
+#### II.2.2 Dimension
+
+International standard: None.
+Conditions: Accordance to the technical specification drawing for the product.
+Acceptance criteria: Full compliance with the specification drawing.
+
+#### II.2.3 Bend radius of optical fibres on the cassette
+
+International standard: IEC 61300-3-3 Method 1.
+Conditions: Min. bend radius 30 mm;
+Wavelength:
+Single mode: $\lambda = 1\,550 \pm 30$ nm; $\lambda = 1\,310 \pm 30$ nm;
+Multimode: $\lambda = 1\,300 \pm 30$ nm; $\lambda = 850 \pm 30$ nm.
+Acceptance criteria: The change in insertion loss after storing a fibre on a storage cassette should be less than 0.05 dB (residual loss).
+
+### II.3 Environmental characteristics
+
+#### II.3.1 Temperature cycling
+
+International standard: IEC 61300-2-22; [b-IEC 60068-2-14] Test Nb.
+Conditions: Lowest temperature: $-40 \pm 2^\circ\text{C}$ ;
+Highest temperature: $+60 \pm 2^\circ\text{C}$ ;
+Dwell time: 2.5 h;
+Transition time: 1 h;
+Pressure: at least 40 kPa;
+Number of cycles: 20.
+Acceptance criteria: Tightness. Visual.
+Max increase of attenuation $< 0.1$ dB.
+
+#### **II.3.2 Temperature: Heat durability**
+
+International standard: [b-IEC 61300-2-18]; [b-IEC 60068-2-2].
+
+Conditions: Temperature: $60 \pm 3^\circ\text{C}$ ;
+Pressure: at least 40 kPa;
+Test time: 7 days.
+
+Acceptance criteria: Tightness. Visual.
+
+#### **II.3.3 Temperature: Cold durability**
+
+International standard: [b-IEC 61300-2-17]; IEC 60068-2-1.
+
+Conditions: Temperature: $-30 \pm 3^\circ\text{C}$ ;
+Pressure: at least 40 kPa;
+Test time: 10 days.
+
+Acceptance criteria: Tightness. Visual.
+
+#### **II.3.4 Resistance to aggressive media**
+
+International standard: IEC 61300-2-34.
+
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Pressure: $40 \pm 2$ kPa;
+Test media: pH 2 solution of hydrochloric acid, pH 12 solution of sodium hydroxide, Diesel fuel, Gasoline, 10% Igepal CO-630;
+Test time: 10 days.
+
+Acceptance criteria: Tightness. Visual.
+
+#### **II.3.5 Corrosive atmosphere**
+
+International standard: [b-IEC 60068-2-11] test Ka; IEC 61300-2-26.
+
+Conditions: Salt fog spray (5% NaCl);
+Temperature: $35 \pm 3^\circ\text{C}$ ;
+Pressure: $40 \pm 2$ kPa;
+Test time: 10 days.
+
+Acceptance criteria: Tightness. Visual: no evidence of corrosion.
+
+#### **II.3.6 Water penetration**
+
+International standard: [b-IEC 61300-2-32].
+
+Conditions: Temperature: $23 \pm 3^\circ\text{C}$ ;
+Depth: 1 m;
+Test time: 7 days.
+
+Acceptance criteria: No water ingress.
+
+#### **II.3.7 Freeze/thaw**
+
+International standard: None.
+
+Conditions: Lowest temperature: $-35 \pm 2^\circ\text{C}$ ;
+Highest temperature: $60 \pm 2^\circ\text{C}$ ;
+Depth: min 25 mm from top part of closure;
+Dwell time on the lowest temperature: 10 h;
+Dwell time on the highest temperature: 5 h;
+Thaw time: 1 h;
+Freeze time: 0.5 h;
+Middle temperature during 1 h: $0^\circ\text{C}$ ;
+
+Next freeze time: 0.5 h;
+Pressure: $40 \pm 2$ kPa;
+Number of cycles: 10.
+
+Acceptance criteria: Tightness. Visual.
+
+### **II.4 Mechanical characteristics**
+
+#### **II.4.1 Axial tension**
+
+International standard: IEC 61300-2-4.
+
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Pressure: at least 40 kPa;
+Load: 450 N;
+Test time: 30 min per cable.
+
+Acceptance criteria: Tightness. No residual cable movement.
+
+#### **II.4.2 Vibration**
+
+International standard: IEC 60068-2-6 test Fc; IEC 61300-2-1.
+
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Vibration: 10–55 Hz, sinusoidal;
+Amplitude: 0.75 mm;
+Pressure: $40 \pm 2$ kPa;
+Test time: 2 h along each of three axes;
+ $\lambda = 1\,550$ nm; Min 8 fibres per test circuit.
+
+Acceptance criteria: Tightness. Visual. Max increase of attenuation after test $< 0.1$ dB.
+
+#### **II.4.3 Torsion strength**
+
+International standard: [b-IEC 60068-2-17]; IEC 61300-2-5.
+
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Pressure: $40 \pm 2$ kPa;
+Load: $50\text{ N} \times \text{m}$ or $90^\circ$ during 5 min in each direction;
+Clamping distance: $10 \times D_{\text{cab}}$ from outlet of cable;
+Number of cycles: 2 per cable.
+
+Acceptance criteria: Tightness. No residual movement of cable.
+
+#### **II.4.4 Bending strength**
+
+International standard: IEC 61300-2-37.
+
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Pressure: $40 \pm 2$ kPa;
+Load: 500 N or $30^\circ$ ;
+Clamping distance: $10 \times D_{\text{cab}}$ from outlet of cable;
+Number of cycles: 5.
+
+Acceptance criteria: Tightness. No movement of cable.
+
+#### **II.4.5 Impact**
+
+International standard: IEC 61300-2-12 Method B.
+Conditions: Test temperature: $-15 \pm 3^\circ\text{C}$ (condition for min 4 h);
+Pressure: $40 \pm 2 \text{ kPa}$ ;
+Impact tool: steel ball;
+Height: 1 m;
+Weight: 1 kg;
+Site of impact: in the middle of the closure;
+Number of impacts: 1.
+Acceptance criteria: Tightness. Visual.
+
+#### **II.4.6 Static load**
+
+International standard: IEC 61300-2-10.
+Conditions: Test temperature: $-15 \pm 3^\circ\text{C}$ ;
+Pressure: $40 \pm 2 \text{ kPa}$ ;
+Load: 1 000 N/25 cm2 area;
+Test time: 10 min.
+Acceptance criteria: Tightness. Visual.
+
+#### **II.4.7 Drop**
+
+International standard: IEC 61300-2-12 method A.
+Conditions: Test temperature: $23 \pm 3^\circ\text{C}$ ;
+Height: 2 m;
+Number of drops: 1.
+Acceptance criteria: Tightness. Visual.
+
+#### **II.4.8 Ultraviolet resistance**
+
+International standard: [b-ISO 4892-3].
+Conditions: Temperature: UV at $60^\circ\text{C}$ during 4 h and dark at $50^\circ\text{C}$ during 4 h;
+Test time: 1 000 h;
+Ultraviolet light source with a peak emission at 313 nm;
+Number of samples: 10.
+Acceptance criteria: The change in tensile strength shall not exceed 20%.
+
+### **II.5 Field condition tests**
+
+#### **II.5.1 Re-entry**
+
+International standard: IEC 61300-2-33.
+Conditions: 1 re-entry and reclose over 1 month in real field conditions.
+Acceptance criteria: Tightness.
+
+## Bibliography
+
+- [b-ITU-T G.Sup59] ITU-T G-series Recommendations – Supplement 59 (2018), *Guidance on Optical Fibre and Cable Reliability*.
+- ITU-T Manual Protection of telecommunication lines and equipment against lightning discharges.
+
+- [b-EN 590] EN 590 (2009), *Automotive fuels. Diesel. Requirements and test methods*.
+- [b-IEC 60068-2-2] International Standard IEC60068-2-2:2007, *Environmental Testing – Part 2-2: Tests – Test B: Dry heat*.
+- [b-IEC 60068-2-11] International Standard IEC 60068-2-11:2021, *Environmental Testing – Part 2-11: Tests – Test Ka: Salt Mist*.
+- [b-IEC 60068-2-14] International Standard IEC 60068-2-14:2009, *Environmental Testing – Part 2-14: Tests – Test N: Change of Temperature*.
+- [b-IEC 60068-2-17] International Standard IEC 60068-2-17:1994, *Basic Environmental Testing Procedures – Part 2-17: Tests – Test Q: Sealing*.
+- [b-IEC 61073-1] International Standard IEC 61073-1:2009, *Fibre Optic Interconnecting Devices and Passive Components – Mechanical Splices and Fusion Splice Protectors for Optical Fibres and Cables – Part 1: Generic Specification*.
+- [b-IEC 61300-2-17] International Standard IEC 61300-2-17:2010, *Fibre Optic Interconnecting Devices and Passive Components - Basic Test and Measurement Procedures - Part 2-17: Tests – Cold*.
+- [b-IEC 61300-2-18] International Standard IEC 61300-2-18:2005, *Fibre Optic Interconnecting Devices and Passive Components – Basic Test and Measurement Procedures – Part 2-18: Tests – Dry Heat - High Temperature Endurance*.
+- [b-ISO 4892-3] ISO 4892-3:2016, *Plastics – Methods of Exposure to Laboratory Light Sources – Part 3: Fluorescent UV Lamps*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.206-201708-I_PDF-E/raw.md b/marked/L/T-REC-L.206-201708-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..0a054a66e28960674ac896222684264c19133954
--- /dev/null
+++ b/marked/L/T-REC-L.206-201708-I_PDF-E/raw.md
@@ -0,0 +1,919 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.206**
+
+(08/2017)
+
+SERIES L: ENVIRONMENT AND ICTS, CLIMATE
+CHANGE, E-WASTE, ENERGY EFFICIENCY;
+CONSTRUCTION, INSTALLATION AND PROTECTION
+OF CABLES AND OTHER ELEMENTS OF OUTSIDE
+PLANT
+
+Optical infrastructures – Infrastructure including node
+elements (except cables)
+
+# --- **Requirements for passive optical nodes – Outdoor optical cross-connect cabinets**
+
+Recommendation ITU-T L.206
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+## ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
+
+| | |
+|---------------------------------------------------------------|--------------------|
+| OPTICAL FIBRE CABLES | |
+| Cable structure and characteristics | L.100–L.124 |
+| Cable evaluation | L.125–L.149 |
+| Guidance and installation technique | L.150–L.199 |
+| OPTICAL INFRASTRUCTURES | |
+| Infrastructure including node elements (except cables) | L.200–L.249 |
+| General aspects and network design | L.250–L.299 |
+| MAINTENANCE AND OPERATION | |
+| Optical fibre cable maintenance | L.300–L.329 |
+| Infrastructure maintenance | L.330–L.349 |
+| Operation support and infrastructure management | L.350–L.379 |
+| Disaster management | L.380–L.399 |
+| PASSIVE OPTICAL DEVICES | L.400–L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430–L.449 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T L.206
+
+# Requirements for passive optical nodes – Outdoor optical cross-connect cabinets
+
+## Summary
+
+Recommendation ITU-T L.206 refers to outdoor optical cross-connect cabinets deployed as passive optical nodes in outdoor environments. It deals with the cabinet housing, internal fibre management system, cable attachment and termination system, and also specifies the mechanical and environmental characteristics.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T L.206 | 2017-08-13 | 15 | 11.1002/1000/13296 |
+
+## Keywords
+
+Enclosures, interconnection, optical cross-connect cabinets, outside plant, passive optical nodes.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2017
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|---------------------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 3.1 Terms defined elsewhere ..... | 2 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 3 |
+| 5 Conventions ..... | 3 |
+| 6 Characteristics of optical cross-connect cabinets ..... | 3 |
+| 6.1 General requirements..... | 3 |
+| 6.2 Cabinet housing ..... | 4 |
+| 6.3 Fibre management system (organizer system) ..... | 5 |
+| 6.4 Cable attachment and termination system..... | 8 |
+| 7 Performance evaluation test programme ..... | 9 |
+| 8 Sample preparation ..... | 9 |
+| Annex A – Performance evaluation criteria..... | 11 |
+| A.1 Mechanical and sealing evaluation..... | 11 |
+| A.2 Optical evaluation..... | 11 |
+| Annex B – Performance test programme for ground level and above ground cabinets ..... | 13 |
+| B.1 Mechanical and sealing evaluation..... | 13 |
+| B.2 Optical evaluation..... | 15 |
+| Appendix I – Sample illustrations of cabinet structure ..... | 17 |
+| Appendix II – Product characterization checklist ..... | 21 |
+| Bibliography..... | 24 |
+
+# Introduction
+
+Cabinets are widely used for protection of cross-connection points among multiple cables in outdoor environments. A cabinet along with internal functional assemblies can be referred to as an outdoor cross-connect cabinet.
+
+An optical cross-connect cabinet comprises a mechanical structure (cabinet housing) for mechanical protection and environmental sealing of internal systems, a fibre management system for guiding and managing the fibres and fibre connections inside the node, and a cable attachment and termination system for attaching and terminating the cable ends. Patch cords, splitters and other passive optical devices are optional accessories of a cabinet. The optical cross-connect cabinet will:
+
+- work as a cross-connection area in outdoor plant;
+- protect the fibres, fibre joints and optical devices from the outdoor environment at ground level (normally, on a concrete base) and above ground (e.g., wall mounted or pole mounted by steel supports);
+- provide for the organization of the fibre joints, passive devices and the storage of fibre overlength (excess fibre length);
+- provide electrical bonding and grounding of the metal parts of the cable sheath and strength members.
+
+This Recommendation specifies the requirements of optical cross-connect cabinets and the means for characterization and evaluation of the performance of cabinets according to the principles of [ITU-T L.200]. This includes mechanical performance, sealing performance and optical stability of the product which simulate the effect of environmental factors or interventions related to network maintenance and reconfiguration. It contains a basic test programme for the cabinet that is globally applicable. Additional requirements may be agreed between customer and supplier to reflect local or special conditions. All functions and features that a product may contain should be reflected in the mix of test samples that are subjected to the test programme.
+
+# Requirements for passive optical nodes – Outdoor optical cross-connect cabinets
+
+# 1 Scope
+
+This Recommendation:
+
+- refers to optical cross-connect cabinets as passive optical nodes in outdoor environments;
+- deals with the cabinet housing as well as the fibre management system, and the cable attachment and termination system;
+- specifies mechanical and environmental characteristics of the optical cabinets;
+- specifies characteristics of the fibre management system;
+- provides a test plan for the performance evaluation of outdoor optical cross-connect cabinets;
+- supplies the simulation of the effect of interventions related to network maintenance and reconfiguration;
+- gives a checklist for a systematic product characterization according to [ITU-T L.200].
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T G.652] Recommendation ITU-T G.652 (2016), *Characteristics of a single-mode optical fibre and cable*.
+- [ITU-T G.657] Recommendation ITU-T G.657 (2016), *Characteristics of a bending-loss insensitive single-mode optical fibre and cable*.
+- [ITU-T K.11] Recommendation ITU-T K.11 (2009), *Principles of protection against overvoltages and overcurrents*.
+- [ITU-T K.47] Recommendation ITU-T K.47 (2012), *Protection of telecommunication lines against direct lightning flashes*.
+- [ITU-T L.200] Recommendation ITU-T L.200/L.51 (2003), *Passive node elements for fibre optic networks – General principles and definitions for characterization and performance evaluation*.
+- [ITU-T L.361] Recommendation ITU-T L.361/L.64 (2012), *ID tag requirements for infrastructure and network elements management*.
+- [IEC 60529] IEC 60529:2013, *Degrees of protection provided by enclosures (IP Code)*.
+- [IEC 61300-2-1] IEC 61300-2-1:2009, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)*.
+
+- [IEC 61300-2-4] IEC 61300-2-4:1995, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-4: Tests – Fibre/cable retention.*
+- [IEC 61300-2-5] IEC 61300-2-5:2009, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-5: Tests – Torsion.*
+- [IEC 61300-2-9] IEC 61300-2-9:2017, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-9: Tests – Shock.*
+- [IEC 61300-2-12] IEC 61300-2-12:2009, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-12: Tests – Impact.*
+- [IEC 61300-2-22] IEC 61300-2-22:2007, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-22: Tests – Change of temperature.*
+- [IEC 61300-2-26] IEC 61300-2-26:2006, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-26: Tests – Salt mist.*
+- [IEC 61300-2-33] IEC 61300-2-33:2012, *Fibre optic interconnecting devices and passive components - Basic test and measurement procedures – Part 2-33: Tests – Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures.*
+- [IEC 61300-2-34] IEC 61300-2-34:2009, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-34: Tests – Resistance to solvents and contaminating fluids of interconnecting components and closures.*
+- [IEC 61300-2-37] IEC 61300-2-37:2016, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-37: Tests – Cable bending for fibre optic closures.*
+- [IEC 61300-3-1] IEC 61300-3-1 (2005), *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-1: Examinations and measurements – Visual examination.*
+- [IEC 61300-3-3] IEC 61300-3-3:2009, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-3: Examinations and measurements – Active monitoring of changes in attenuation and return loss.*
+- [IEC 61300-3-28] IEC 61300-3-28:2012, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 3-28: Examinations and measurements – Transient loss.*
+
+# 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 optical cross-connect cabinet:** A cabinet with an integrated fibre management system to protect the cross-connections of optical fibre cables.
+
+**3.2.2 cabinet housing:** The outer shell of a cabinet, including lockable doors and not including the fibre management system or the cable attachment and termination system. Its main functions are protection and sealing of its contents.
+
+**3.2.3 fibre management system (organizer system):** The whole of the means and features that guide and store fibres and passive devices inside a node, at any location where they are not protected by the cable sheath. In a cabinet, the optical fibres are properly managed and guided from where cables enter the node until their exit.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|---------------------------------|
+| ID | Identification |
+| IP | Ingress Protection |
+| ME | Multiple Element (mass storage) |
+| OA | Outdoor Above ground |
+| OG | Outdoor Ground level |
+| SC | Single Circuit |
+| SE | Single Element |
+| SF | Single Fibre |
+| SMC | Sheet Moulding Compound |
+| SR | Single Ribbon |
+
+# **5 Conventions**
+
+None.
+
+# **6 Characteristics of optical cross-connect cabinets**
+
+## **6.1 General requirements**
+
+The general structure of optical cabinets is shown in Figure 1.
+
+
+
+Diagram of the general structure of optical cabinets. It shows a rectangular cabinet housing containing three modules or units on the left and a fibre management system on the right. Below the modules is a cable attachment and termination area. Two cables enter the cabinet from the bottom. Labels with arrows point to: Cabinet housing, Fibre management system, Module or unit, Cable attachment and termination, and Cable. The diagram is labeled L.206(17)\_F01.
+
+**Figure 1 – General structure of optical cabinets**
+
+Each cabinet should comply with the general requirements as listed in clause 8 of [ITU-T L.200].
+
+Figures I.1 to I.4 show examples of cabinets to illustrate their structures and internal fibre organization systems.
+
+## 6.2 Cabinet housing
+
+The following should be considered:
+
+- dimensions should be compatible with internal contents and installation site. Generally, the maximum height of cabinet should be less than 1.6 m;
+- the doors should be re-openable for installation, maintenance or reconfiguration. The opening angle of the door should not be less than 110° and the lock on the door should have sufficient protection ability;
+- the protection level of the cabinet housing should comply with the requirements of IP54 or higher degrees in [IEC 60529];
+- the cabinet housing should be made from high strength materials to provide sufficient mechanical strength, e.g., metal or sheet moulding compound (SMC; sheet form glass-fibre reinforced polyester material processed by compression moulding);
+- the metallic parts of the cabinet housing should be electrically bonded and grounded;
+- the housing should allow access for multiple cable ends. The cables may be of different sizes or types. Normally, the cables enter the cabinet from the bottom of the housing via cable entry holes. The apertures between cables and the housing should allow sealing by putty or other materials to ensure adequate performance, and the sealing material should be easily removable for reconfiguration;
+- the housing should stand and be fixable on a concrete base or steel supports;
+- if the housing is limited to use in certain applications and environments in the network, any limitations should be clearly indicated to the user – a detailed characterization of features and compatibility of a cabinet can be assessed using the checklist in Appendix II;
+- if necessary, a cabinet can be equipped with an access control system that makes remote door control (via a dedicated network) available;
+
+- materials that will be exposed to solar radiation should be resistant to ultraviolet light. All polymeric materials that are exposed to the environment should be sufficiently resistant to fungi. Metallic parts should be corrosion resistant when exposed to the salt mist test [IEC 61300-2-26].
+
+## **6.3 Fibre management system (organizer system)**
+
+The fibre management system is an integral part of an optical cross-connect cabinet. The system comprises units or modules and support frames that have means for routing and holding fibre joints, fibre overlength, patch cords and other possible passive devices (splitters, adapters, etc.) in an orderly manner, and should minimize fibre strain.
+
+Compatibility and features of fibre management system can be assessed by using the checklist in Appendix II. The desired optical stability type can be selected according to [ITU-T L.200].
+
+### **6.3.1 Functions of the fibre management system**
+
+The functions of the optical fibre management system are:
+
+- to provide means for routing, storing and protecting fibre joints or other passive devices in a predetermined order, from one cable sheath end to another;
+- to provide means for installation, reconfiguration and expansion of fibre circuits, to make the cabinet a flexible optical cross-connection point;
+- to separate circuits up to a certain degree as defined in [ITU-T L.200]. This will limit the risk of interruption of traffic to those fibres that belong to the same group of circuits (see [ITU-T L.200]: single fibre (SF), single circuit (SC), single ribbon (SR), single element (SE) or multiple element (ME). For an optical cross-connect cabinet, a separation degree higher than SE is preferred;
+- to provide means for storing the fibre overlength required for jointing and for possible re-jointing in the future;
+- to ensure that the fibre bend radius is not less than 30 mm in general applications with ITU-T G.652 fibres. For special applications, a minimum bend radius of 20 mm can be agreed between customer and supplier (in order to maintain mechanical reliability and minimize losses in the network, the cumulative length of fibre exposed to this smaller bend radius should be limited to less than 2 m per fibre link). In the case of ITU-T G.657 fibres, smaller bend radius is allowed (see [b-ITU-T G-Sup.59] for guidance on optical fibre and cable reliability);
+- to provide easy identification and access to any connectors and stored fibre joints for maintenance and reconfiguration, all optical connectors (including optical adapters and plugs) should be labelled clearly and uniquely to identify their routes. Electronic identification (ID) is optional, which should comply with the requirements of [ITU-T L.361].
+
+The materials used for making the management system should be compatible with the other materials in the cabinet and the degreasing agents as recommended in the installation instructions.
+
+### **6.3.2 Modules of fibre management system**
+
+The fibre management system may contain the following modules:
+
+#### **a) Splice modules**
+
+Splice modules, normally in the form of trays, are used for storing and protecting fibre splices and fibre overlength.
+
+Splice modules can store splices of the fibres from the ingoing and outgoing cables together (direct splicing modules) or can store splices of the fibres from the ingoing and outgoing cables to pigtails.
+
+In some cases, the splice modules can store the splitter components which are then spliced to the fibres of the cables or pigtails.
+
+#### b) Distribution modules
+
+Distribution modules, normally in the form of trays, have fibre distribution function that allows a cross-connection between the ingoing and outgoing fibres by using patch panels. Typically, patch cords are used in cross-connection between the distributing modules.
+
+##### c) Storage modules for cable overlength (excess cable length)
+
+Storage modules, normally in the form of winding wheels, are capable of storing cable overlength of patch cords and pigtails. Normally, storage of fibre overlength is done in the splice modules.
+
+#### d) Splitter modules
+
+Splitter modules, normally in the form of trays with splitters inside or individual splitters, are capable of splitting optical power into different branches of the network. In most cases, the splitter ports are connectorized to allow fast installation or reconfiguration.
+
+Several functions of different modules can be combined into one module. For example, some modules have combined the splicing and the distribution function into one "splice and distribution module".
+
+Modules in the form of trays may be organized in one of the following ways:
+
+- lateral sliding from a frame – similar to removing a book from a shelf;
+- lateral rotation about a vertical axial – similar to turning a blade out of a pen knife;
+- hinging – similar to turning pages in a book.
+
+All movements of the trays should proceed in a predetermined and controlled way in order to reduce optical losses or interruption of traffic during organizer manipulations.
+
+#### **6.3.3 Configurations of optical fibre management system**
+
+Various configurations of the fibre management system in the cross-connect cabinet are possible: a) to h).
+
+#### a) Direct splice without splitters
+
+
+
+Diagram of Figure 2: Direct splice without splitters. A central box labeled 'Splice module' contains two circles representing fiber coils with an 'X' marking the splice point between them. An arrow labeled 'In' enters from the left, and an arrow labeled 'Out' exits to the right. The technical label 'L.206(17)\_F02' is at the bottom right of the diagram.
+
+**Figure 2 – Direct splice without splitters**
+
+#### b) Direct splice with splitters
+
+
+
+Diagram of Figure 3: Direct splice with splitters. Three boxes are arranged horizontally. The first box is labeled 'Splice' and contains two fiber coils with an 'X' splice. An arrow labeled 'In' enters this box. The second box is labeled 'Splitter' and shows a single line splitting into three. The third box is labeled 'Splice' and contains two fiber coils with an 'X' splice. An arrow labeled 'Out' exits this final box. The technical label 'L.206(17)\_F03' is at the bottom right.
+
+**Figure 3 – Direct splice with splitters**
+
+#### c) Interconnect without splitters
+
+
+
+Diagram of interconnect without splitters (Figure 4). It shows a flow from 'In' to 'Out' through two main modules. The first module, labeled 'Several functions can be combined into one "splice and distribution" module', contains a 'Splice' unit (two circles with an X) and a 'Distribution (patch panel)' unit (a vertical bar with four horizontal lines). The second module, labeled 'Several functions can be combined into one "splice-pigtail" module', contains an 'Overlength storage (pigtails)' unit (two overlapping circles) and another 'Splice' unit. The flow is: In -> Splice -> Distribution -> Overlength storage -> Splice -> Out. A reference code 'L.206(17)\_F04' is at the bottom right.
+
+**Figure 4 – Interconnect without splitters**
+
+#### d) Interconnect with splitters
+
+
+
+Diagram of interconnect with splitters (Figure 5). It shows a flow from 'In' to 'Out' through two main modules. The first module, labeled 'Several functions can be combined into one "splice, splitter and distribution" module', contains a 'Splice tray' (two circles with an X), a 'Splitter' (one line splitting into three), and a 'Distribution (patch panel)' unit. The second module, labeled 'Several functions can be combined into one "splice-pigtail" module', contains an 'Overlength storage (pigtails)' unit and a 'Splice' unit. The flow is: In -> Splice tray -> Splitter -> Distribution -> Overlength storage -> Splice -> Out. A reference code 'L.206(17)\_F05' is at the bottom right.
+
+**Figure 5 – Interconnect with splitters**
+
+#### e) Cross-connect without splitters
+
+
+
+Diagram of cross-connect without splitters (Figure 6). It shows a flow from 'In' to 'Out' through three main modules. The first module, labeled 'Several functions can be combined into one "splice and distribution" module', contains a 'Splice tray' and a 'Distribution (patch panel)' unit. The second module is an 'Overlength storage (patch cords)' unit (two overlapping circles). The third module, also labeled 'Several functions can be combined into one "splice and distribution" module', contains a 'Distribution (patch panel)' unit and a 'Splice tray'. The flow is: In -> Splice tray -> Distribution -> Overlength storage -> Distribution -> Splice tray -> Out. A reference code 'L.206(17)\_F06' is at the bottom right.
+
+**Figure 6 – Cross-connect without splitters**
+
+#### f) Cross-connect with splitters integrated in modules with splice tray and patch panel
+
+
+
+L.206(17)\_F07
+
+Figure 7: Cross-connect with splitters integrated in modules with splice tray and patch panel. The diagram shows a flow from 'In' to 'Out' through two main modules. The first module, labeled 'Several functions can be combined into one "splice, splitter and distribution" module', contains 'Splice', 'Splitter', and 'Distribution (patch panel)'. The second module, labeled 'Several functions can be combined into one "splice and distribution" module', contains 'Distribution (patch panel)' and 'Splice'. Between these modules is an 'Overlength storage (patch cords)' section.
+
+**Figure 7 – Cross-connect with splitters integrated in modules with splice tray and patch panel**
+
+g) Cross-connect with individual pigtailed splitter modules
+
+
+
+L.206(17)\_F08
+
+Figure 8: Cross-connect with individual pigtailed splitter modules. The diagram shows a flow from 'In' to 'Out' through several components. On the left, a dashed box labeled 'Several functions can be combined into one "splice and distribution" module' contains 'Splice to pigtail' and 'Distribution (patch panel)'. This is followed by 'Overlength storage (pigtails)', a 'Splitter', another 'Overlength storage (pigtails)', and then a second dashed box labeled 'Several functions can be combined into one "splice and distribution" module' containing 'Distribution (patch panel)' and 'Splice to pigtail'.
+
+**Figure 8 – Cross-connect with individual pigtailed splitter modules**
+
+h) Cross-connect with individual splitter and distribution modules
+
+
+
+L.206(17)\_F09
+
+Figure 9: Cross-connect with individual splitter and distribution modules. The diagram shows a flow from 'In' to 'Out' through three dashed boxes. The first box, labeled 'Several functions can be combined into one "splice-pigtail" module', contains 'Splice to pigtail' and 'Overlength storage (pigtails)'. The second box, labeled 'Several functions can be combined into one "splice and distribution" module', contains 'Distribution (patch panel)', 'Splitter', and 'Distribution (patch panel)'. The third box, labeled 'Several functions can be combined into one "splice-pigtail" module', contains 'Overlength storage (pigtails)' and 'Splice to pigtail'.
+
+**Figure 9 – Cross-connect with individual splitter and distribution modules**
+
+If required, the fibre management system can be divided into multiple subsystems and stored in separate regions in the cabinet so that multiple telecommunication operators can share the subscriber cables and the space inside the cabinet. In this case, the separated regions should be independently lockable and easy to identify.
+
+## **6.4 Cable attachment and termination system**
+
+The following characteristics of cable attachment and termination system should be considered:
+
+- the system should allow for attachment of all cables entering the cabinet. The cables may be of different sizes or types;
+
+- the system should allow for good bonding and grounding for metallic elements of cables, while the cable metallic elements should be insulated to other metallic parts of the cabinet. The method of achieving electrical continuity will vary with the type of cable sheath and the type and location of the strength members. Further information is given in [ITU-T K.11] and [ITU-T K.47];
+- the system should be installed near the cable entry points in the cabinet, normally the lower section of the cabinet inner housing;
+- the system should allow the addition or removal of cables with no interruption to service on other cables;
+- the materials used in the system should be compatible with the other materials in the cabinet and the degreasing agents recommended in the installation instructions.
+
+# 7 Performance evaluation test programme
+
+The complete test programme for an optical cross-connect cabinet consists of:
+
+- a basic test programme for the applicable environment (see Annexes A and B);
+- a number of additional requirements according to local standards when necessary (see [ITU-T L.200] and the checklist in Appendix II).
+
+For specific products, alternative test conditions to those given in Annex B may be agreed between customer and supplier.
+
+Tests should be executed according to IEC 61300-2-series test methods where available.
+
+The performance test programme of an optical cross-connect cabinet should:
+
+- evaluate the product for two groups of criteria: mechanical and sealing evaluation, and optical stability (see Annex A);
+- simulate the effects of exposure to:
+ - the environment in which it will be installed,
+ - an intervention at the node;
+- simulate installation or maintenance conditions;
+- evaluate all available features of the product.
+
+When an optical cross-connect cabinet is suitable for both outdoor above ground (OA) and outdoor ground level (OG) environments (see [ITU-T L.200]), it should pass the most severe conditions of either environment. As an alternative, the tests that are different for each of these environments may be duplicated at both settings.
+
+Two types of optical stability can be selected (see clause 6.2.1 of [ITU-T L.200]). For products that may be subject to an intervention on a live network, dynamic optical stability is recommended.
+
+# 8 Sample preparation
+
+A representative number of test samples is to be prepared, taking into account the following parameters:
+
+- all product features and compatibility (see checklist in Appendix II);
+- applicable sizes of cables;
+- sealing performance test samples should be installed at $-15^{\circ}\text{C}$ , room temperature or $+45^{\circ}\text{C}$ ;
+- optical performance test samples should be installed at room temperature;
+
+- for mechanical evaluation, a fresh sample should be prepared for each different test; if a failure occurs when consecutive testing is applied on the same sample, the failed test may be repeated on a fresh sample.
+
+Appendix I of [ITU-T L.200] illustrates how optical samples can be prepared. Due to their complexity, consecutive testing on the same sample is most practical.
+
+## Annex A
+
+## Performance evaluation criteria
+
+(This annex forms an integral part of this Recommendation.)
+
+### **A.1 Mechanical and sealing evaluation**
+
+The performance evaluation criteria should be satisfied during or after performing the tests specified in Annex B.
+
+#### **A.1.1 Sealing performance**
+
+International Standard: [IEC 60529].
+
+Conditions: Conditions according to protection degree of the cabinet
+(IP54 or higher).
+
+Requirement: Meet the requirements of the protection degree of the cabinet
+(IP54 or higher).
+
+#### **A.1.2 Visual examination**
+
+International Standard: [IEC 61300-3-1].
+
+Conditions: Examination of product with the unaided naked eye.
+
+Requirement: No defects or physical damages that would affect product performance.
+
+### **A.2 Optical evaluation**
+
+NOTE 1 – All optical losses indicated are referenced to the initial optical signal at the start of the test.
+
+NOTE 2 – An incoming fibre is defined as a part of an optical circuit containing the fibre entering the product, spliced to a fibre leaving the product. One optical circuit can contain many incoming fibres. Light will sequentially flow through all the incoming fibres.
+
+NOTE 3 – Fibre type used for single mode: ITU-T G.652 D fibre. The applications with other fibre types (e.g., ITU-T G.657 fibre) will be qualified by similarity since most fibre types are equally or less sensitive to bending compared to ITU-T G.652 D fibre.
+
+#### **A.2.1 Change in insertion loss (attenuation) (static optical stability)**
+
+International Standard: [IEC 61300-3-3] Method 1.
+
+Conditions: Source wavelength: 1 310 nm, 1 550 nm and 1 625 nm
+
+Requirement: **If only splices are part of the optical path:**
+
+$\Delta IL \leq 0.2$ dB (1 310 nm/1 550 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.5$ dB (1 625 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.1$ dB (1 310 nm/1 550 nm/1 625 nm) per incoming fibre after the test (residual loss).
+
+##### **If optical connectors are part of the optical path:**
+
+$\Delta IL \leq 0.2$ dB (1 310 nm/1 550 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.5$ dB (1 625 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.2$ dB (1 310 nm/1 550 nm/1 625 nm) per incoming fibre after the test (residual loss).
+
+##### **If optical splitter is part of the optical path:**
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.8$ dB (1 625 nm) per incoming fibre during the test (excursion loss);
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm/1 625 nm) per incoming fibre after the test (residual loss).
+
+#### **A.2.2 Transient loss (dynamic optical stability)**
+
+International Standard: [IEC 61300-3-28].
+
+Conditions: Source wavelength: 1 310 nm, 1 550 nm and 1 625 nm (measurements at 1 550 nm and 1 625 nm are particularly important for dynamic transient loss. 1 310 nm is optional, subject to agreement between customer and supplier), unpolarized; Detector bandwidth: (0-1 500) Hz.
+
+Requirement: **If only splices are part of the optical path:**
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm) during the test measured in the life circuit (transient loss);
+
+$\Delta IL \leq 1.0$ dB (1 625 nm) during the test measured in the life circuit (transient loss);
+
+$\Delta IL \leq 0.1$ dB (1 310 nm/1 550 nm/1 625 nm) after the test in the life circuit (residual loss).
+
+##### **If optical connectors are part of the optical path:**
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm) during the test measured in the life circuit (transient loss).
+
+$\Delta IL \leq 1.0$ dB (1 625 nm) during the test measured in the life circuit (transient loss).
+
+$\Delta IL \leq 0.2$ dB (1 310 nm/1 550 nm/1 625 nm) after the test in the life circuit (residual loss).
+
+##### **If optical splitter is part of the optical path:**
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm) per incoming fibre during the test (excursion loss).
+
+$\Delta IL \leq 1.0$ dB (1 625 nm) per incoming fibre during the test (excursion loss).
+
+$\Delta IL \leq 0.5$ dB (1 310 nm/1 550 nm/1 625 nm) per incoming fibre after the test (residual loss).
+
+## Annex B
+
+### Performance test programme for ground level and above ground cabinets
+
+(This annex forms an integral part of this Recommendation.)
+
+For tests in this annex, the test settings are applicable for cabinets used in both environments OG and OA unless specifically marked. All testing is at room temperature unless otherwise stated. When sealing performance evaluation for dust and water ingress is required, it can be performed after all related tests have been finished, instead of after each of the tests. In optical evaluations in clause B.2, the requirements for static or dynamic optical stability are to be agreed between customer and supplier, and the appropriate optical performance criteria are to be selected accordingly.
+
+### B.1 Mechanical and sealing evaluation
+
+#### B.1.1 Static load (crush test) on the top of cabinet
+
+International Standard: [IEC 61300-2-10]
+
+Conditions: Vertical load (N): $1\,750\text{ (Pa)} \times \text{Cabinet width (m)} \times \text{Cabinet depth (m)}$ and minimum 500
+Application: uniformly distributed on the top surface
+Test time: 10 min.
+
+Performance criteria: Sealing performance; Visual examination
+
+#### B.1.2 Static load on cabinet door
+
+International Standard: [IEC 61300-2-10]
+
+Conditions: Vertical load: 200 N
+Point of application: far end of the top of opening door, at the most extreme point that creates the highest moment
+Test time: 10 min
+
+Performance criteria: Sealing performance; Visual examination
+
+#### B.1.3 Resistance to side load
+
+International Standard: None
+
+Conditions: Fully equipped cabinet and in installed condition
+Force (N) = $1\,500\text{ (Pa)} \times \text{Width (m)} \times \text{Height (m)}$
+Point of application: most extreme point located away from attachment points
+Direction: in the axis that will generate the highest moment, performed in the two directions.
+Duration: 5 s
+
+Performance criteria: Visual appearance
+
+#### B.1.4 Cable retention force
+
+International Standard: [IEC 61300-2-4]
+
+Conditions: Install cables of appropriate type on the cabinet
+ Load per cable: $D/45 \text{ mm} \times 1\,000 \text{ N}$ (maximum $1\,000 \text{ N}$ ), where $D$ is the cable outer diameter in millimetres
+ Test time: 1 h per cable
+
+Performance criteria: Visual appearance
+
+If the performance of the cable attachment and termination system is not influenced by other components, the system can be taken down from the cabinet to do the test.
+
+#### **B.1.5 Cable bending**
+
+International Standard: [IEC 61300-2-37]
+
+Conditions: Bending angle $\pm 30^\circ$ or maximum bending force $500 \text{ N}$ is reached
+ Point of application: $400 \text{ mm}$ from the cable entry of the cabinet. For cables with a very rigid construction (e.g., slotted core cables, armoured cables), the clamping distance may need to be increased to $1\,000 \text{ mm}$ .
+ Keep angle for 5 min at each extreme position.
+ Number of cycles: five per cable
+
+Performance criteria: Visual appearance
+
+#### **B.1.6 Cable torsion**
+
+International Standard: [IEC 61300-2-5]
+
+Conditions: Install cables of appropriate type on the cabinet
+ Torsion angle $\pm 90^\circ$ or maximum torque $50 \text{ N m}$ is reached
+ Torque application: $400 \text{ mm}$ from the cable entry of the cabinet. For cables with a very rigid construction (e.g., slotted core cables, armoured cables), the clamping distance may need to be increased to $1\,000 \text{ mm}$ .
+ Duration at extreme position: 5 min
+ Number of cycles: five per cable
+
+Performance criteria: Visual appearance
+
+If the performance of the cable attachment and termination system is not influenced by other components, the system can be taken down from the cabinet to do the test.
+
+#### **B.1.7 Impact**
+
+International Standard: [IEC 61300-2-12] Method B
+
+Conditions: Impact tool: Steel ball
+ Mass: $1 \text{ kg}$
+ Drop height: $1 \text{ m}$
+ Test temperatures: $(-15 \pm 2)^\circ \text{C}$ and $(+45 \pm 2)^\circ \text{C}$ ;
+ Location: at the centres of the cabinet at $0^\circ$ (the centre of the front door), $90^\circ$ , $180^\circ$ , $270^\circ$ around the longitudinal axis, and on top of the cabinet
+ Number of impacts: one per location.
+
+Performance criteria: Sealing performance; Visual examination: No evidence of cracks and deformations, surface protective layer (if there is one) does not fall off, scratches on surface can be ignored
+
+#### **B.1.8 Temperature cycling (OG and OA)**
+
+International Standard: [IEC 61300-2-22]
+
+Conditions (see Note): Lowest/highest temperature: $(-40/+65 \pm 2)$ °C
+Humidity: uncontrolled
+Dwell time: 4 h
+Transition: 1 °C/min
+Number of cycles: 12
+
+Performance criteria: Sealing performance; Visual appearance
+
+NOTE – Temperature ranges for temperature cycling are typical values. Adaptations to specific local conditions can be agreed between customer and supplier. Humidity could also be considered.
+
+#### **B.1.9 Re-entries**
+
+International Standard: [IEC 61300-2-33]
+
+Conditions: Open all cabinet doors to maximum angle and close at each re-entry
+Aging between each re-entry: at least one thermal cycle (see clause B.1.9)
+Number of re-entries: five
+
+Performance criteria: Sealing performance; Visual appearance
+
+#### **B.1.10 Salt mist**
+
+International Standard: [IEC 61300-2-26]
+
+Conditions: Exposure to a salt mist of 5% NaCl in water
+Test temperature: $(+35 \pm 2)$ °C
+Duration: 5 days
+
+Performance criteria: Visual appearance: No evidence of corrosion
+
+The salt mist test can be selectively performed on components, parts and materials that are at potential risk of corrosion, instead of the whole cabinet.
+
+#### **B.1.11 Resistance to aggressive media (as needed)**
+
+International Standard: [IEC 61300-2-34]
+
+Conditions: Exposure to: HCl at pH 2
+NaOH at pH 12
+Duration: 5 days
+
+Performance criteria: Visual appearance: No evidence of corrosion, swelling or cracks
+
+The resistance to aggressive media test can be selectively performed on components, parts and materials that are at potential risk of corrosion, instead of the whole cabinet.
+
+### **B.2 Optical evaluation**
+
+Construction of optical samples is according to Appendix I of [ITU-T L.200].
+
+#### **B.2.1 Intervention at a node**
+
+International Standard: [IEC 61300-2-33]
+
+Conditions: Execute all manipulations that will normally occur for this product during an intervention after initial installation. A list of typical manipulations can be found in Appendix II of [ITU-T L.200]
+
+Performance criteria: Visual appearance; Static: Change in attenuation (residual loss)
+Dynamic: Transient loss
+
+#### **B.2.2 Vibration**
+
+International Standard: [IEC 61300-2-1]
+
+Conditions: Sweep range: (5-500) Hz sinusoidal at 1 octave/min
+Crossover frequency: 9 Hz
+– amplitude below 9 Hz: 1.2 mm
+– acceleration above 9 Hz: $4 \text{ m/s}^2$ ( $\sim 0.4g$ )
+Direction: three mutually perpendicular axes
+Duration: 10 cycles (5-500-5) Hz/axis
+
+Performance criteria: Visual appearance
+Static: Change in attenuation (residual loss)
+Dynamic: Transient loss
+
+#### **B.2.3 Shock**
+
+International Standard: [IEC 61300-2-9]
+
+Conditions: Wave form: Half sine
+Duration: 11 ms
+Acceleration: $50 \text{ m/s}^2$ ( $\sim 5g$ )
+Direction: three mutually perpendicular axes
+Number of shocks: three up and three down per axis
+
+Performance criteria: Visual appearance
+Static: Change in attenuation (residual loss)
+Dynamic: Transient loss
+
+#### **B.2.4 Temperature cycling (OG and OA)**
+
+International Standard: [IEC 61300-2-22]
+
+Conditions (see Note): Lowest/highest temperature: $(-40/+65 \pm 2) ^\circ\text{C}$
+Humidity: uncontrolled
+Dwell time: 4 h
+Transition: $1 ^\circ\text{C/min}$
+Number of cycles: 12
+
+Performance criteria: Visual appearance
+Static: Change in attenuation (excursion and residual loss)
+
+NOTE – Temperature ranges for temperature cycling are typical values. Adaptations to specific local conditions can be agreed between customer and supplier. Humidity could also be considered.
+
+## Appendix I
+
+### Sample illustrations of cabinet structure
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Figures I.1 to I.4 show examples of cabinets to illustrate their structures and internal fibre organization systems. In practice, the design of cabinet structure and internal modules varies.
+
+
+
+The photograph shows the interior of an open optical fibre management cabinet. The cabinet is light grey with a hinged door on the right side. Inside, various optical fibre management components are visible, each highlighted with a red rectangular box and connected to a text label by a red line. The labels and their corresponding components are: 'Storage modules (winding wheels)' pointing to three vertical spools on the left; 'Splitter modules (individual splitters)' pointing to two small rectangular modules below the storage wheels; 'Direct splice modules (trays)' pointing to a green rectangular module on the bottom left; 'Splice and distributing modules (trays)' pointing to two large green rectangular modules in the upper right; 'Cabinet housing' pointing to the bottom section of the cabinet; and 'Cable attachment and termination system' pointing to a horizontal rail at the bottom right. The 'Door' is labeled on the right side of the cabinet door. The cabinet contains numerous yellow optical fibre cables and some white cables.
+
+Figure I.1: Cabinet structure example I. A photograph of an open optical fibre management cabinet with various internal components labeled.
+
+L.206(17)\_FI.1
+
+**Figure I.1 – Cabinet structure example I**
+
+Available configurations of optical fibre management system (see clause 6.3.3) of example I in Figure I.1:
+
+- direct splice without splitters;
+- cross-connect without splitters;
+- cross-connect with individual pigtailed splitters.
+
+
+
+Figure I.2 – Cabinet structure example II. A photograph of an open optical fibre management cabinet. The cabinet is light grey with a hinged door on the right. Inside, there are several modules and trays. At the top, a red line points to 'Splice-pigtail modules (Trays)'. On the left, a red line points to 'Splitter modules (individual splitters)'. In the middle, a red line points to 'Direct splice modules (Trays)'. At the bottom, a red line points to 'Cable attachment and termination system'. The bottom of the cabinet has a ventilation grille and a small label. The door is open, showing its inner structure and a label on the inside.
+
+L.206(17)\_FI.2
+
+**Figure I.2 – Cabinet structure example II**
+
+Available configurations of optical fibre management system (see clause 6.3.3) of example II in Figure I.2:
+
+- direct splice without splitters;
+- cross-connect with individual splitters integrated in distribution modules.
+
+
+
+Figure I.3 – Cabinet structure example III. A central image shows an open optical fibre management cabinet with its door open. Four callout images with red lines pointing to specific parts of the cabinet are included: 'Splitter modules' (top left), 'Direct splice modules and splice-pigtail modules' (bottom left), 'Splice and distribution modules' (top right), and 'Cable attachment and termination system' (bottom right). The label 'Door' is at the top left with a line pointing to the cabinet door.
+
+L.206(17)\_FI.3
+
+**Figure I.3 – Cabinet structure example III**
+
+Available configurations of optical fibre management system (see clause 6.3.3) of example III in Figure I.3:
+
+- direct splice without splitters;
+- direct splice with splitters;
+- interconnect without splitters;
+- interconnect with individual pigtailed splitters;
+- cross-connect without splitters;
+- cross-connect with individual pigtailed splitters.
+
+
+
+Figure I.4 – Cabinet structure example IV. The main image shows an open outdoor cabinet with three red boxes highlighting internal components. Red lines connect these boxes to three inset images: the top one shows 'Splitter modules', the middle one shows 'Splice and distribution modules', and the bottom one shows 'Cable attachment and termination system'. The label 'Cabinet housing' points to the main cabinet structure. The text 'L.206(17)\_FI.4' is in the bottom right corner.
+
+**Figure I.4 – Cabinet structure example IV**
+
+Available configurations of optical fibre management system (see clause 6.3.3) of example IV in Figure I.4:
+
+- cross-connect with individual pigtailed splitters.
+
+## Appendix II
+
+### Product characterization checklist
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This checklist facilitates the systematic characterization of the features and capabilities of an optical cross-connect cabinet. It reflects the parameters that are described in [ITU-T L.200]. It may be useful for preparation of the test programme of products as well as product descriptions for tenders and purchasing specifications, comparison of different or competitive products and creation of commercial information and ordering guides.
+
+**Product name:** .....
+
+### Material of cabinet housing
+
+- Metal
+- SMC
+- Other: .....
+
+### Application environment(s) (see clause 7.1 of [ITU-T L.200])
+
+- OG Outdoor ground level
+- OA Above ground level
+- E Extreme (describe differences versus a basic environmental class)
+
+### Ingress protection (IP) protection class
+
+- IP54
+- IP55
+- Other: .....
+
+### Optical functionality and compatibility (see clause 6 of [ITU-T L.200])
+
+- *optical stability level:*
+ - Static
+ - Dynamic (transient free)
+- *wavelength* (see clause 6.3 of [ITU-T L.200])
+ - 1 310 nm
+ - 1 550 nm
+ - 1 625 nm
+ - Other: .....
+
+- **cable construction** (see clause 6.1.1 of [ITU-T L.200])
+ - Loose buffer tube
+ - Micro-sheath
+ - Central core
+ - Slotted core
+ - Blown fibre
+ - Break out cable
+ - Interfacility cable
+ - Optical Power Ground Wire (OPGW) cable
+ - Other: .....
+- **fibre type, fibre grouping, fibre coating** (see clause 6.1.2 of [ITU-T L.200])
+ - Multimode
+ - Single mode
+ - Single fibre
+ - Ribbon 4
+ - R8
+ - R12
+ - R24
+ - other: .....
+ - Primary coated (~250 µm)
+ - Secondary coated (~900 µm)
+- **passive devices** (see clause 6.1.3 of [ITU-T L.200]):
+ - Splice type: Fusion
+ - Mechanical (brand/type): .....
+ - Splice protector type:
+ - Heatshrink (min/max dimensions): .....
+ - Mechanical (brand/type) : .....
+ - Connectors: specify brand/type: .....
+ - Branching devices: (describe type, split ratio etc.): .....
+ - Delivered as preassembled/prefibred modules yes no
+ - Other passive devices: (describe) .....
+ - Delivered as preassembled/prefibred modules yes no
+
+- ***fibre storage and separation level*** (see clause 6.2.2 of [ITU-T L.200])
+
+| | Circuit separation level | | | | |
+|-----------------------------------------------------|--------------------------|--------------------------|--------------------------|--------------------------|--------------------------|
+| | ME | SE | SR | SC | SF |
+| Uncut fibre (looped fibre) | | | | | |
+| Splices | | | | | |
+| Passive optical components | | | | | |
+| Other: ..... | | | | | |
+
+### Additional or special requirements and features
+
+- ***storage/transport conditions*** (see clause 7.2 of [ITU-T L.200])
+ - Normal: public transport – indoor storage
+ - Special handling/transport: .....
+ - Special storage: .....
+- ***additional (conditional) requirements*** (see Appendix III of [ITU-T L.200]):
+ - Bullet/shotgun proof according to: .....
+ - Earthquake resistance according to: .....
+ - Freeze-thaw resistance according to: .....
+ - Fire-related performance according to: .....
+ - Fire retardancy according to: .....
+ - Halogen free according to: .....
+ - Low smoke emission according to: .....
+ - Electrical grounding and shield continuity according to: .....
+ - Current surge according to: .....
+ - Insulation resistance according to: .....
+ - Contact resistance according to: .....
+ - Rodent resistance according to: .....
+ - Termite resistance according to: .....
+ - Steam resistance according to: .....
+ - Cable blocking according to: .....
+ - Other: ..... according to: .....
+
+## Bibliography
+
+- [b-ITU-T G-Sup.59] ITU-T G-series Recommendations – Supplement 59 (2016), *Guidance on optical fibre and cable reliability*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.21-199610-I_PDF-E/raw.md b/marked/L/T-REC-L.21-199610-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..d9a7342b64f3cc417d36a04e16885363ade8555d
--- /dev/null
+++ b/marked/L/T-REC-L.21-199610-I_PDF-E/raw.md
@@ -0,0 +1,425 @@
+
+
+
+
+The logo of the International Telecommunication Union (ITU) features a globe with a lightning bolt striking through it, symbolizing telecommunications.
+
+ITU logo
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.21**
+
+(10/96)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS
+OF OUTSIDE PLANT
+
+---
+
+**Fire detection and alarm systems, detector and
+sounder devices**
+
+ITU-T Recommendation L.21
+
+(Previously CCITT Recommendation)
+
+---
+
+# ITU-T L-SERIES RECOMMENDATIONS **CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+*For further details, please refer to ITU-T List of Recommendations.*
+
+# FOREWORD
+
+The ITU-T (Telecommunication Standardization Sector) is a permanent organ of the International Telecommunication Union (ITU). The ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Conference (WTSC), which meets every four years, establishes the topics for study by the ITU-T Study Groups which, in their turn, produce Recommendations on these topics.
+
+The approval of Recommendations by the Members of the ITU-T is covered by the procedure laid down in WTSC Resolution No. 1 (Helsinki, March 1-12, 1993).
+
+ITU-T Recommendation L.21 was prepared by ITU-T Study Group 6 (1993-1996) and was approved by the WTSC (Geneva, 9-18 October 1996).
+
+---
+
+# NOTES
+
+1. In this Recommendation, the expression “Administration” is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+2. The status of annexes and appendices attached to the Series L Recommendations should be interpreted as follows:
+ - an *annex* to a Recommendation forms an integral part of the Recommendation;
+ - an *appendix* to a Recommendation does not form part of the Recommendation and only provides some complementary explanation or information specific to that Recommendation.
+
+# CONTENTS
+
+| | Page |
+|-------------------------------------------------------------------|-------------|
+| 1 Introduction ..... | 1 |
+| 2 Detectors ..... | 1 |
+| 2.1 Automatic detectors ..... | 1 |
+| 2.2 Manual detectors..... | 2 |
+| 3 It is recommended that ..... | 2 |
+| 3.1 General..... | 2 |
+| 3.2 Circuit design..... | 2 |
+| 3.3 Detectors ..... | 3 |
+| 3.4 Visual alarms ..... | 4 |
+| 3.5 Communication with the fire brigade ..... | 4 |
+| Appendix I – United Kingdom experience ..... | 4 |
+| Appendix II – Japanese experience ..... | 5 |
+| Appendix III – Argentinian experience ..... | 6 |
+| Appendix IV – United States experience..... | 6 |
+| IV.1 Building construction..... | 6 |
+| IV.2 Fire prevention..... | 7 |
+| IV.3 Fire system installation and related codes..... | 7 |
+| IV.4 Telecommunications Equipment Fire Resistance Standards ..... | 7 |
+
+# **FIRE DETECTION AND ALARM SYSTEMS, DETECTOR AND SOUNDER DEVICES**
+
+*(Geneva, 1996)*
+
+## **1 Introduction**
+
+In order to protect property and, when applicable, life, protective fire detection and alarm systems can be installed to initiate a number of different activities:
+
+- detection and location of a fire;
+- provision of assistance to contain and/or extinguish the fire;
+- emergency evacuation procedures;
+- summoning of fire-fighting forces.
+
+It should be noted that a fire detection and alarm system can do nothing to reduce the incidence of fires. It can however reduce the delay between ignition and effective fire-fighting. A satisfactory alarm system for the protection of property will automatically detect the fire at an early stage, raise an effective alarm in time to summon the fire-fighting forces and indicate the location of the fire. An early alarm of fire enhances the safety of personnel by increasing their chances of escape.
+
+Taking into account the risk of fire and action to reduce the magnitude of danger from fire, quick detection is the first criterion to be considered followed by the activation of extinguishing measures.
+
+Detection devices are part of the automatic fire detection and alarm systems. These systems monitor continuously, or at frequent intervals, the physical and/or chemical characteristics of a protected fire area (zone).
+
+The function of detectors is to identify fires as soon as possible and, through the control and indicating equipment, to activate alarms and adopt pertinent measures to extinguish possible fire breakouts, to evacuate personnel and to notify safety and fire-fighting services. These detectors function directly with fire alarm equipment and automatic fire-extinguishing systems, to minimize the damage caused by fire.
+
+## **2 Detectors**
+
+### **2.1 Automatic detectors**
+
+In accordance with functional characteristics (detection technologies used) and technological characteristics (discrete identification or variable threshold detection), the detectors to be installed are classified as follows.
+
+#### **2.1.1 Heat detectors**
+
+According to the way in which the sensing is done, they are classified as:
+
+- *Fixed temperature*
+These are designed to operate when they reach a pre-selected threshold temperature.
+- *Rate-of-rise of temperature (differential)*
+These are designed to operate when the environmental temperature rises abnormally quickly.
+- *Combination*
+To respond to both very slow growing and rapidly developing fires.
+
+#### **2.1.2 Smoke detectors**
+
+According to the way in which the sensing is done, they are classified as:
+
+- *Ionization chamber smoke detectors*
+These rely on the reduction of an electric current flowing between the electrodes in an ionization chamber when smoke particles enter the chamber. They are particularly sensitive to smoke containing small particles such as are produced in rapidly burning fires.
+
+##### – *Optical smoke detectors*
+
+These are designed to operate by detecting the scattering or absorption of light by smoke particles. They are sensitive to the larger particles found in optically dense smoke produced by smouldering fires.
+
+##### – *Volumetric or beam detectors*
+
+These work on the principle of optical obscuration and detect the presence of smoke in only a small part of the beam. Some optical beam smoke detectors can also sense thermal turbulence from a fire by detecting the refraction of the beam at turbulent interfaces between hot and cold air.
+
+#### 2.1.3 Flame detectors
+
+According to the way in which the sensing is done, they are classified as:
+
+##### – *Ultraviolet radiation detectors*
+
+These use ultraviolet radiation sensitive cells that see the fire directly or through built-in lenses or reflectors.
+
+##### – *Infrared radiation detectors*
+
+These use infrared radiation sensitive cells that see the fire directly or through built-in lenses or reflectors. They are designed to respond to the flickering radiation emitted by the diffusion type of flame normally found in fires.
+
+#### 2.1.4 Addressable detectors
+
+These components of the fire alarm system have a discrete identification that can have its status individually identified or that is used to individually control other functions.
+
+#### 2.1.5 Intelligent detectors
+
+These have the capability of modifying automatically their detection thresholds according to the environmental conditions.
+
+### 2.2 Manual detectors
+
+These manually triggered devices (manual call points) are placed in buildings because they allow an earlier warning to be given than the automatic detection and alarm system if personnel are present at the ignition of a fire.
+
+#### 2.2.1 Manual sounders (audible alarms)
+
+Sounders can be used manually to give an alarm of fire.
+
+Where there are other parts of the building unlikely to be affected by the fire, the system may be arranged that the sounders are only activated manually only in the zone with the fire and in adjoining areas for the evacuation of personnel to safe areas.
+
+## 3 It is recommended that
+
+### 3.1 General
+
+As a fire can start almost anywhere within a building and if undetected grow until extinction becomes difficult or impossible, the highest level of property protection is recommended with the detection and alarm system installed throughout the building.
+
+### 3.2 Circuit design
+
+The design of a fire detection and alarm system should provide reliable facilities for transmission of signals to the control and indicating equipment from manual call points (manual detectors) or automatic detectors and for the transmission of any resultant fire signal to both sounders and ancillary equipment which is operated by the fire detection and alarm system.
+
+An indication should be given of any fault in the wiring circuits or power supply without giving a false fire alarm.
+
+A fault in one zone should not affect the operation of the fire detection and alarm system in other zones of the building. Disruption during maintenance and testing should be minimized. Where sounders use the same wiring as detectors, no alarm sounder should be affected by the removal of a detector for maintenance. Where a sounder is removed for maintenance, a fault warning should appear at the control and indicating equipment.
+
+Where microprocessors are used in fire detection and alarm systems, their memories should be protected against unauthorised interference. Also, their operation should be continuously monitored for accidental corruption, for example by transient interference.
+
+### **3.3 Detectors**
+
+Suitable detectors should be placed in all zones (fire areas) which are to be fire protected and should convey an alarm to the control and indicating equipment either by hard wiring or by wireless.
+
+The combustion characteristics of all materials present in a fire area (zone) should be analysed to ascertain the type or types of detector to be installed.
+
+In accordance with functional characteristics (detection technologies used) and technological characteristics (discrete identification or variable threshold detection) the detectors to be installed are classified as follows.
+
+#### **3.3.1 Heat detectors**
+
+These devices should be placed in fire areas (zones) with defined temperature thresholds and where smoke may normally be present, that is in kitchens and diesel engine rooms.
+
+#### **3.3.2 Smoke detectors**
+
+These devices should be placed in fire areas (zones) where ignited elements generate smoke before breaking out into flames.
+
+#### **3.3.3 Flame detectors**
+
+These devices should be placed in fire areas (zones) to detect flames from ignited elements.
+
+#### **3.3.4 Intelligent detectors**
+
+These devices should be placed in fire areas (zones) in buildings of high complexity and with a diversity of combustible elements, equipment and personnel. They may be either smoke or heat detectors.
+
+#### **3.3.5 Manual detectors (manual call points)**
+
+These devices should be placed in fire area (zones) frequented by personnel. They should be located on exit routes and floor landings of stairways, located within a specified distance (for example, 30 m) of personnel work places and be easily identifiable against a contrasting background.
+
+#### **3.3.6 Manual sounders (audible alarms)**
+
+The acoustic signalling devices of the fire alarm system should be distributed throughout the building so that its signal emitted either automatically or manually would be audible in any place.
+
+In rooms containing customers and service personnel, the acoustic signal should be of lower power, though perfectly audible, because the permanent presence of personnel ensures detection of the alarm at lower power levels. If the loudness level is very high it could induce panic, nervous excitement and confusion in the customers.
+
+The sounder frequencies should preferably be in the range of 500 Hz to 1000 Hz.
+
+Buildings of several floors should have at least one audible alarm per floor.
+
+The wiring of sounder circuits should be arranged so that in the event of a short circuit developing in any part of the circuits due to the fire, at least one sounder will continue to operate. This minimum provision should ensure that a general alarm can be given at the start of a fire and for a significant period thereafter. Where the single sounder is not audible throughout the building, sounder cables likely to resist fire for a sufficient period should be used.
+
+Where the fire detection and alarm system extends to other parts of the building unlikely to be affected by the fire, the system may be arranged such that the alarms sound in the area (zone) with the fire and in adjoining areas, for the evacuation of personnel to safe areas. Or the system may be arranged such that the alarms only sound in the zone with the fire.
+
+It should not be possible to prevent the transmission of the alarm by the act of silencing the alarm sounders nor should it depend on the state of any silencing switch.
+
+### **3.4 Visual alarms**
+
+In areas where high sound levels may persist for more than 30 s, (for example, in diesel rooms with an engine running) visual alarms (for example, in the form of a flashing light) should be used. The wiring of the circuit should be arranged with the same precautions as those described above for sounders (audio alarms).
+
+### **3.5 Communication with the fire brigade**
+
+The responsibility of calling the fire brigade should be both clearly specified and understood. A special telephone line should be routed through the building to avoid areas where fire is likely to start or spread rapidly. The line should be barred from receiving incoming calls and it should only be used for emergency outgoing calls.
+
+## **Appendix I**
+
+### **United Kingdom experience**
+
+Within the United Kingdom, British Standard BS 5839 takes into account the work of ISO/TC 21/SC 3 – Fire detection and alarm systems.
+
+The various parts of the British Standards specification are:
+
+- BS 5839: Part 1 – Fire detection and alarm systems for buildings.
+Part 1 – Code of practice for system design, installation and servicing.
+- BS 5839: Part 2 – Fire detection and alarm systems for buildings.
+Part 2 – Specification for manual call points.
+- BS 5839: Part 3 – Fire detection and alarm systems for buildings.
+Part 3 – Specification for automatic release mechanisms for certain fire protection equipment.
+- BS 5839: Part 4 – Fire detection and alarm systems for buildings.
+Part 4 – Specification for control and indicating equipment.
+- BS 5839: Part 5 – Fire detection and alarm systems for buildings.
+Part 5 – Specification for optical beam smoke detectors.
+
+British Standard BS 5445 covers parts of EN 54 components of automatic fire detection systems produced by Technical Committee CEN/TC 74. These are:
+
+- BS 5445: Part 5 – Components of automatic fire detection systems.
+Part 5 – Heat sensitive detectors – Point detectors containing a static element.
+
+- BS 5445: Part 7 – Components of automatic fire detection systems.
+Part 7 – Specification for point type smoke detectors using scattered light, transmitted light or ionization.
+- BS 5445: Part 8 – Components of automatic fire detection systems.
+Part 8 – Specification for high temperature heat detectors.
+
+## Appendix II Japanese experience
+
+### **Japanese Standards relating to Fire Detection and Alarm Systems**
+
+#### *Automatic fire alarm system*
+
+| | |
+|----------------------------------|-----------------------------------|
+| Fire Law Enforcement Ordinances: | Clause 21 |
+| Fire Law Enforcement Regulation: | Clause 23 Clause 24, Article 2 |
+
+#### *Gas leak fire alarm system*
+
+| | |
+|----------------------------------|----------------------------|
+| Fire Law Enforcement Ordinances: | Clause 21, Article 2 |
+| Fire Law Enforcement Regulation: | Clause 24, Articles 2 to 4 |
+
+#### *Short circuit fire warning equipment*
+
+| | |
+|----------------------------------|----------------------|
+| Fire Law Enforcement Ordinances: | Clause 22 |
+| Fire Law Enforcement Regulation: | Clause 24, Article 3 |
+
+#### *Fire alarm system that notified fire fighting organizations*
+
+| | |
+|----------------------------------|-----------|
+| Fire Law Enforcement Ordinances: | Clause 23 |
+| Fire Law Enforcement Regulation: | Clause 25 |
+
+#### *Emergency warning equipment and installations*
+
+| | |
+|----------------------------------|----------------------|
+| Fire Law Enforcement Ordinances: | Clause 24 |
+| Fire Law Enforcement Regulation: | Clause 25, Article 2 |
+
+### **Japanese Standards relating to Evacuation and Guiding Equipment**
+
+#### *Evacuation equipment*
+
+| | |
+|----------------------------------|-------------------|
+| Fire Law Enforcement Ordinances: | Clause 25 |
+| Fire Law Enforcement Regulation: | Clauses 26 and 27 |
+
+#### *Emergency lighting and markers*
+
+| | |
+|----------------------------------|------------------------------|
+| Fire Law Enforcement Ordinances: | Clause 26 |
+| Fire Law Enforcement Regulation: | Clause 28, Article 3 |
+| Building Standards Law: | Clause 126, Articles 4 and 5 |
+
+#### *Emergency entrance*
+
+| | |
+|-------------------------|------------------------------|
+| Building Standards Law: | Clause 126, Articles 6 and 7 |
+|-------------------------|------------------------------|
+
+#### *Emergency Elevator*
+
+| | |
+|-------------------------|---------------------------------------------|
+| Building Standards Law: | Clause 129, Points 2 and 3 of Article 13 |
+|-------------------------|---------------------------------------------|
+
+## Appendix III
+
+## Argentinian experience
+
+IRAM are the initials of National Institute of Rationalization and Materials – Member of ISO (International Organization for Standardization) – COPANT (Panamerican Commission of Technical Rules).
+
+| | |
+|------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| NORMA IRAM 3531:1982 | INSTALACIONES FIJAS CONTRA INCENDIO. Sistemas de detección y alarma. Definiciones y descripción de detectores. (ERR.84/10). |
+| NORMA IRAM 3551:1982 | INSTALACIONES FIJAS CONTRA INCENDIO. Sistemas de detección y alarma. Aplicaciones. |
+| NORMA IRAM 3552:1984 | INSTALACIONES FIJAS CONTRA INCENDIO. Detector de temperatura, puntual. |
+| NORMA IRAM 3554:1987 | INSTALACIONES FIJAS CONTRA INCENDIO. Sistemas de detección y alarma. Proyecto y montaje de la instalación. |
+| NORMA IRAM 3557:1988 | INSTALACIONES FIJAS CONTRA INCENDIO. DETECTORES. Métodos de ensayo de respuesta al fuego. |
+| NORMA IRAM 3558:1989 | INSTALACIONES FIJAS CONTRA INCENDIO. Sistemas de detección y alarma. Tableros de control y señalización. |
+| NORMA IRAM 3582:1990 | INSTALACIONES FIJAS CONTRA INCENDIO. DETECTORES DE HUMO, POR IONIZACIÓN, POR LUZ DIFUSA Y POR LUZ TRANSMITIDA. (REV. IRAM 3582: 1982; 1983 y sus modificaciones posteriores). |
+| NORMA IRAM 3657-1:1990 | INSTALACIONES FIJAS CONTRA INCENDIO. DETECTORES DE GASES COMBUSTIBLES Y MEZCLAS EXPLOSIVAS. Prescripciones generales. |
+| NORMA IRAM 3659:1991 | INSTALACIONES FIJAS CONTRA INCENDIO. DETECTORES DE LLAMA. |
+
+## Appendix IV
+
+## United States experience
+
+### IV.1 Building construction
+
+United States model building codes: in the United States, there are several different building codes. Different codes are adopted in different areas of the country. The three major building codes are:
+
+- national building code;
+- standard building code;
+- uniform building code.
+
+### **IV.2 Fire prevention**
+
+United States model fire prevention codes: in the United States, there are several different fire codes. Different codes are adopted in different areas of the country. The three major fire prevention codes are:
+
+- national fire prevention code;
+- standard fire prevention code;
+- uniform fire code.
+
+### **IV.3 Fire system installation and related codes**
+
+United States National Standards: National Fire Protection Association (NFPA) – National Fire Codes.
+
+### **IV.4 Telecommunications Equipment Fire Resistance Standards**
+
+United States National Standards: American National Standards Institute (ANSI) Standard T1.307, Fire Resistance Criteria.
+
+### **Summary of Fire Safety Regulations in the United States**
+
+In the United States, little fire protection is federally mandated. Employers are required to provide a safe working environment, but the protection from fire is not specified.
+
+Regulations are mandated by state or local jurisdictions. Rather than actually writing the codes from beginning to end, most jurisdictions elect to adopt one of the three model code series. A series includes building, plumbing, mechanical, and fire prevention regulations. The three model code series are:
+
+- 1) The National Code series which, among others, includes the National Fire Prevention Code and National Building Code developed and published by the Building Officials and Code Administrators (BOCA).
+- 2) The Standard Code series which, among others, includes the Standard Fire Prevention Code and Standard Building Code developed and published by the Southern Building Code Congress International (SBCCI).
+- 3) The Uniform Code series which, among others, includes the Uniform Fire Code and the Uniform Building Code developed and published by the International Fire Code Institute (IFCI).
+
+Membership in these organizations is open, but voting privileges on code changes and related issues are reserved for registered building and fire officials.
+
+The National Code series is adopted in the north-east and part of the mid-west of the United States. The Standard Code series is adopted by the south-eastern states of the United States. The Uniform Code series is adopted by almost all of the states west of the Mississippi River.
+
+The three model code organizations are moving towards developing one code. A joint organization has been created called the International Code Council (ICC) with the responsibility of developing one unified code. The Board of the ICC is made up of 12 seats with four allotted to each of the model code organizations.
+
+So far, the ICC has developed and published a unified Model Plumbing Code which is now available for adoption. They have plans to come out with unified Model Mechanical, Building and Fire Prevention Codes by the year 2000.
+
+Other organizations also develop and publish standards and codes. These are available for adoption by the Model Code Organizations or by the States directly. The one that develops the fire prevention and protection standards and codes is the National Fire Protection Association (NFPA).
+
+
+
+# ITU-T RECOMMENDATIONS SERIES
+
+- Series A Organization of the work of the ITU-T
+- Series B Means of expression: definitions, symbols, classification
+- Series C General telecommunication statistics
+- Series D General tariff principles
+- Series E Overall network operation, telephone service, service operation and human factors
+- Series F Non-telephone telecommunication services
+- Series G Transmission systems and media, digital systems and networks
+- Series H Audiovisual and multimedia systems
+- Series I Integrated services digital network
+- Series J Transmission of television, sound programme and other multimedia signals
+- Series K Protection against interference
+- Series L Construction, installation and protection of cables and other elements of outside plant**
+- Series M Maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits
+- Series N Maintenance: international sound programme and television transmission circuits
+- Series O Specifications of measuring equipment
+- Series P Telephone transmission quality, telephone installations, local line networks
+- Series Q Switching and signalling
+- Series R Telegraph transmission
+- Series S Telegraph services terminal equipment
+- Series T Terminals for telematic services
+- Series U Telegraph switching
+- Series V Data communication over the telephone network
+- Series X Data networks and open system communication
+- Series Z Programming languages
\ No newline at end of file
diff --git a/marked/L/T-REC-L.27-199610-I_PDF-E/raw.md b/marked/L/T-REC-L.27-199610-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..396ed37d8f8ee4267d2c217a8fd0b12ad06fcea8
--- /dev/null
+++ b/marked/L/T-REC-L.27-199610-I_PDF-E/raw.md
@@ -0,0 +1,626 @@
+
+
+
+
+The logo of the International Telecommunication Union (ITU) features the letters 'ITU' in a bold, sans-serif font, superimposed on a stylized globe with intersecting lines.
+
+ITU logo
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.27**
+
+(10/96)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS
+OF OUTSIDE PLANT
+
+---
+
+**Method for estimating the concentration of
+hydrogen in optical fibre cables**
+
+ITU-T Recommendation L.27
+
+(Previously CCITT Recommendation)
+
+---
+
+# ITU-T L-SERIES RECOMMENDATIONS **CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT**
+
+*For further details, please refer to ITU-T List of Recommendations.*
+
+# FOREWORD
+
+The ITU-T (Telecommunication Standardization Sector) is a permanent organ of the International Telecommunication Union (ITU). The ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Conference (WTSC), which meets every four years, establishes the topics for study by the ITU-T Study Groups which, in their turn, produce Recommendations on these topics.
+
+The approval of Recommendations by the Members of the ITU-T is covered by the procedure laid down in WTSC Resolution No. 1 (Helsinki, March 1-12, 1993).
+
+ITU-T Recommendation L.27 was prepared by ITU-T Study Group 6 (1993-1996) and was approved by the WTSC (Geneva, 9-18 October 1996).
+
+---
+
+# NOTES
+
+1. In this Recommendation, the expression “Administration” is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+2. The status of annexes and appendices attached to the Series L Recommendations should be interpreted as follows:
+ - an *annex* to a Recommendation forms an integral part of the Recommendation;
+ - an *appendix* to a Recommendation does not form part of the Recommendation and only provides some complementary explanation or information specific to that Recommendation.
+
+# CONTENTS
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------------------------------|-------------|
+| Introduction ..... | 1 |
+| Annex A – Measurement of hydrogen released by each cable component by gas chromatography ..... | 2 |
+| A.1 Principle..... | 2 |
+| A.2 Equipment..... | 2 |
+| A.3 Measurement procedures ..... | 2 |
+| A.4 Analysis ..... | 3 |
+| Annex B – Measurement of the concentration of hydrogen in a cable sample ..... | 5 |
+| B.1 Unfilled cable..... | 5 |
+| B.2 Filled cable..... | 5 |
+| Annex C – Measurement of the long-term effectiveness of hydrogen-absorbing materials ..... | 6 |
+| C.1 Principle..... | 6 |
+| C.2 Apparatus..... | 6 |
+| C.3 Measurement procedures ..... | 6 |
+| C.4 Analysis ..... | 6 |
+| Appendix I – UK experience of hydrogen concentrations in moisture barrier optical fibre duct cables..... | 7 |
+| I.1 Field experience..... | 7 |
+| I.2 Analysis ..... | 7 |
+| I.3 References..... | 8 |
+| Appendix II – Japanese experience of the loss increase due to hydrogen generation in water-blocking tape optical fibre cable ..... | 9 |
+| II.1 Structure and materials of the water-blocking tape cable ..... | 9 |
+| II.2 Hydrogen generated from cable components ..... | 9 |
+| II.3 Evaluation of loss increase due to hydrogen generation..... | 9 |
+| II.4 Increase in loss in water-penetrated cable ..... | 10 |
+| Appendix III – Spanish experience of hydrogen generation in moisture barrier optical fibre cables ..... | 12 |
+| III.1 Cable structure ..... | 12 |
+| III.2 Field experience..... | 12 |
+| III.3 Origin of the problem ..... | 12 |
+| III.4 Problem solution..... | 12 |
+
+# **METHOD FOR ESTIMATING THE CONCENTRATION OF HYDROGEN IN OPTICAL FIBRE CABLES**
+
+*(Geneva, 1996)*
+
+## **Introduction**
+
+Considerable experience has been gained using optical fibre cables in terrestrial and subsea applications showing that optical fibres provide a stable transmission medium.
+
+There are some situations where the concentration of hydrogen within a cable can rise to a sufficiently large value to cause the optical loss of the fibre to increase (see Appendix III). Therefore, there is a need to determine the build-up of hydrogen in a cable by considering the ways that hydrogen can be generated within it.
+
+If the escape of hydrogen through the polyolefin sheath or the overlap of a moisture barrier balances the hydrogen generated in the cable, the resulting concentrations within the cable do not cause a noticeable change in optical loss (see Appendices I and II).
+
+### **Considering**
+
+- a) that hydrogen within a cable can result from:
+ - the hydrogen released from the cable components;
+ - the electrolytic action between components of different metal in the presence of moisture;
+ - the corrosive reaction of metallic components in the presence of moisture;
+ - the hydrogen within the air pumped into pressurised cable networks;
+- b) that hydrogen can escape by permeation through the cable sheath except for hermetically sealed sheaths of where the external concentration of hydrogen is greater than that within the cable core;
+- c) that the optical loss change, which is most noticeable at the wavelength of 1.24 µm and/or 1.38 µm, arises from:
+ - a temporary change due to molecular hydrogen within the fibre core which is proportional to the concentration (partial pressure) of hydrogen;
+ - a permanent chemical change which depends on the dopant and its concentration, due to hydroxyl formed by the chemical combination of diffused hydrogen molecules and structural defects in the silica glass of the fibre,
+
+### **it is recommended**
+
+- 1) that for cable types which may allow the concentration of hydrogen within the cable core to build up to a value which could cause a noticeable increase in optical loss:
+ - i) the concentration of hydrogen anticipated within the cable core should be estimated from a knowledge of the hydrogen released from the components of the cable. If desired, the measurement method of gas chromatography described in Annex A can be used to determine the amount of hydrogen released from the cable components;
+ - ii) the concentration of hydrogen in filled cables should be managed by one or more of the following:
+ - minimized by careful selection of the components of the cable;
+ - reduced to zero by the use, within the cable, of a hydrogen-absorbing material which should have an active life comparable to the life of the cable;
+ - have reduced influence on optical performance by the use of hermetically coated fibres or by the use of a hermetic sheath around the cable core in the event of the external concentration of hydrogen being greater than that within the cable core;
+
+- iii) the concentration of hydrogen in unfilled cables should be purged from the cable at regular intervals;
+ - iv) lengths of unfilled prototype cable or specially prepared short samples (up to 10 m) of filled prototype cable may be tested to confirm the estimated concentrations of hydrogen by the measurement method described in Annex B;
+- 2) that the long-term effectiveness of hydrogen-absorbing material, when used, should be confirmed by the measurement method described in Annex C.
+
+For cables of all dielectric construction, there is sufficient experience of stable transmission properties to make unnecessary the testing for significant concentrations of hydrogen which could cause an increase in optical loss.
+
+## Annex A
+
+### Measurement of hydrogen released by each cable component by gas chromatography
+
+### A.1 Principle
+
+Gas chromatography may be used to estimate the hydrogen concentration. The concentration of hydrogen in a vessel is estimated by comparing the N2 , O2 and H2 peaks, measured by gas chromatography, with that of a known hydrogen concentration. Hydrogen release can usually be accelerated by raising the ambient temperature. Such acceleration conditions as temperature and time depend on the volume of the sample. The temperature is usually from 50 °C to 160 °C and the time within 48 h. The elevated temperature should be selected to be below the level which would melt or deform the cable materials. The time should be long enough for the thermal activity to saturate. After thermal activation, the temperature is reduced to its initial level and the hydrogen concentration is measured by gas chromatography. A flow chart, for estimating the amount of hydrogen released in the cable material sample, is shown in Figure A.1.
+
+### A.2 Equipment
+
+The basic equipment is shown in Figure A.2. A gas chromatograph is used for the quantitative analysis of hydrogen. It usually measures the hydrogen content by separating hydrogen from the other gasses by virtue of this element's unique retention time in the column and then determining its concentration with a thermal conductivity detector. The usual conditions of such a gas chromatograph are as follows:
+
+- 1) *Column*
+ - Length: 1 to 4 metres
+ - Filter: Molecular sieve 5A
+ - Temperature: 40 °C to 50 °C
+- 2) *Carrier gas (Argon gas)*
+ - Flow rate: 30 to 40 ml/min
+- 3) *Detector (Thermal conductive detector)*
+ - Temperature range for detection: 25 °C to 50 °C
+
+### A.3 Measurement procedures
+
+#### A.3.1 Sample preparation
+
+Optical fibre cables usually contain components as follows:
+
+- coated silica fibres;
+- polymerised materials, such as:
+ - tubes or slotted rods in which the coated silica glass fibres may be inserted;
+ - wrapping tapes including water-blocking tapes;
+
+- jelly compounds or water-blocking powder which may be used as water-blocking materials;
+- metallic, glass fibre or aramid components which may be used as strength members.
+
+The specimen is prepared as a test sample. It should be placed in an extraction-concentration vessel of known volume, which is filled with air or an inert gas such as argon at atmospheric pressure. The vessel is usually made of glass in preference to metal, since metal surfaces provide a site for hydrogen molecules absorption-desorption phenomena which make reliable testing difficult at low concentrations. The vessel must be hydrogen-proof and not itself a source of hydrogen. In some cases, the sample may be put into a glass ampoule which has a smaller volume than the vessel and the mouth of the ampoule sealed to prevent hydrogen leakage during thermal activation. In such cases the inner volume of the vessel or sealed ampoule should be about ten times or more greater than the volume of the sample for the oxidization reaction.
+
+#### A.3.2 Calibration
+
+The calibrated master line of the gas chromatograph should be determined before measurement. An outline of this procedure is shown in the upper left hand side of the flow chart in Figure A.1. A primary standard of 10 000 ppm of hydrogen in argon is prepared as a master gas that is diluted to the desired concentrations of 10, 20, 50 and 100 ppm. Hydrogen at these concentrations is by a gas chromatograph and the calibrated master line, i.e. the relationship between the gas concentration and the area under the peaks is determined by the least-squares method. Examples of the peaks and the calibrated master line obtained in the calibration are shown in Figure A.3.
+
+#### A.3.3 Measurement
+
+After the sample is prepared, hydrogen released from the test sample is activated thermally according to the procedure shown in the upper right hand side of Figure A.1. At this stage the sample temperature is raised to a predetermined level between 50 °C and 160 °C. The upper temperature limit should be below the level at which the test sample would melt or deform. The time should be long enough to enable the time required for achieving thermal balance to be disregarded and short enough to ensure a reproducible test. Air is preferable as a reaction atmosphere because optical fibres in service are usually surrounded by air and oxidization affects the hydrogen release from organic materials such as jelly compounds and coating resins. Following this, the sample is returned to room temperature.
+
+0.5 ml of gas from within the vessel or ampoule is injected into the gas chromatograph and the hydrogen concentration is obtained from the master line. When an ampoule has been used, it must be broken in the vessel before taking the measurement. The quantity of hydrogen released from the test sample can be derived by:
+
+$$H_2 = A \cdot \frac{V_2}{V_1} \quad (\text{ml/g or ml/cm, for the weight or the length of test sample})$$
+
+where:
+
+$A$ is the hydrogen concentration obtained from the calibrated master line corresponding to the area under the peaks in the gas chromatograph of the extracted gas
+
+$V_1$ is the volume injected into the gas chromatograph
+
+$V_2$ is the internal volume of the vessel
+
+NOTE – Hydrogen in the region of $10^{-5}$ ml and above can usually be detected by this method.
+
+### A.4 Analysis
+
+The maximum quantity of hydrogen generated from a test sample at an elevated temperature can be estimated by the measurement described above. The law in the variation of hydrogen release due to temperature variation is considered to follow an Arrhenius representation:
+
+$$\text{Log } [H_2] = f(1/T)$$
+
+where:
+
+$T$ is the absolute temperature.
+
+The maximum quantity of hydrogen generated from the test sample at the in-service temperature can be calculated by knowing the relationship between the quantity of hydrogen released and the temperature.
+
+
+
+```
+
+graph TD
+ subgraph LeftColumn [ ]
+ L1[Preparation of sample with known hydrogen concentration] --> L2[Sampling with gas-tight syringe]
+ L2 --> L3[Gas chromatography analysis]
+ L3 --> L4[Preparation of calibrated master line]
+ L4 --> L5[Determination of ratio between hydrogen concentration/peak area]
+ end
+ subgraph RightColumn [ ]
+ R1[Sample preparation
+• Measurement (length, weight)
+• Sample placed in vessel] --> R2[Vessel purged with argon gas]
+ R2 --> R3[Thermal activation]
+ R3 --> R4[Vessel cooled to room temperature]
+ R4 --> R5[Sampled with gas-tight syringe]
+ end
+ L5 --> M1[Gas chromatography analysis]
+ R5 --> M1
+ M1 --> M2[Hydrogen concentration in the vessel atmosphere]
+ M2 --> M3[Correction of volume inside the vessel for sample volume]
+ M3 --> M4[Absolute amount of hydrogen]
+ style LeftColumn fill:none,stroke:none
+ style RightColumn fill:none,stroke:none
+ style M1 fill:none,stroke:none
+ style M2 fill:none,stroke:none
+ style M3 fill:none,stroke:none
+ style M4 fill:none,stroke:none
+
+```
+
+Flow chart for the measurement of gas chromatography
+
+T0603940-96/d01
+
+Figure A.1/L.27 – Flow chart for the measurement of gas chromatography
+
+
+
+The diagram illustrates the experimental setup for hydrogen measurement. A dashed box contains a 'Vessel' with a 'Valve' at the top. Inside the vessel is a 'Specimen or Glass ampoule'. A line labeled 'Gas extraction' connects the valve to a 'Gas chromatograph'. To the right of the dashed box is a separate 'Glass ampoule' containing a 'Specimen'.
+
+Equipment configuration for the measurement of hydrogen derived from cable components
+
+T0603680-94/d02
+
+Figure A.2/L.27 – Equipment configuration for the measurement of hydrogen derived from cable components
+
+
+
+Figure A.3/L.27 consists of two parts. Part (a) is a 'Standard chromatogram' showing a baseline with three distinct peaks labeled H2, O2, and N2. A bracket on the right side of the O2 and N2 peaks is labeled 'Air'. Part (b) is a 'Calibrated master line' graph showing 'Relative peak area' on the y-axis (ranging from 0 to 3) versus 'Hydrogen concentration (ppm)' on the x-axis (ranging from 0 to 150). The graph shows a straight line starting at the origin (0,0) and increasing linearly to approximately (150, 2.5). Below part (b) is the text 'T0603690-94/d03'.
+
+**Figure A.3/L.27 – Examples of a chromatograph and calibrated master line used in the measurement of gas chromatography**
+
+## **Annex B**
+
+### **Measurement of the concentration of hydrogen in a cable sample**
+
+### **B.1 Unfilled cable**
+
+#### **B.1.1 Laboratory method**
+
+A length of cable is stored in a climatic chamber with its ends sealed. The gas chromatography measuring technique, described in Annex A, is normally used to examine a sample of gas extracted from the cable.
+
+For non-hermetically sealed cable sheaths, the measurement can be carried out on a sample of sheath to determine the rate of the escape of hydrogen by permeation.
+
+##### **B.1.1.1 Sample preparation**
+
+In order to seal the cable ends into special cable connectors, a primer is used to bond the cable sheath to the adhesive which is applied to each of the metallic cable connectors. To check the gas tightness of the test apparatus, it is first connected to a length of polymer coated seamless metallic tube with a set of cable connectors bonded to each end.
+
+##### **B.1.1.2 Measurement**
+
+After the cable has stabilized to the temperature in the environmental chamber, a sample of gas is drawn out of the cable and the hydrogen concentration is measured. The measurement is repeated.
+
+#### **B.1.2 Field method**
+
+The hydrogen concentration can be measured directly using a fuel cell technique, for example, a portable *Exhaled hydrogen monitor* manufactured for medical use. Where the cable is pressurized, it is possible to measure the concentration of hydrogen by monitoring the gas drawn off at a series of sheath closures along the cable route from valves which form part of the cable pressurization arrangements. A known concentration of hydrogen-air mixture is used to calibrate the monitor.
+
+### **B.2 Filled cable**
+
+The concentration of hydrogen in the internal cable environment is determined by the collection of representative samples in drain tubes fitted within a length of prototype cable and measuring these in accordance with B.1.1.
+
+Tubes, which are small enough not to disturb the internal cable permeable atmosphere, are inserted into the cable core during the manufacture of the cable. Usually, two drains are inserted to keep the volume sampled to less than 1% of the total internal permeable cable volume.
+
+## Annex C
+
+### Measurement of the long-term effectiveness of hydrogen-absorbing materials
+
+### C.1 Principle
+
+A test is required that will demonstrate that hydrogen-absorbing material is capable of absorbing hydrogen by a chemical process throughout the service life of a cable. The test should show that the rate of absorption remains stable with time in order that the amount of getter required to protect the cable can be evaluated.
+
+The test is carried out by placing a known quantity of getter into a closed volume, degassing the material, introducing hydrogen at a known pressure and measuring the absorption of hydrogen by the reduction in pressure after a set period of time. The test is repeated after accelerated ageing of the getter to show a steady rate of absorption. A temperature of 105 °C for one month represents 20 years at ambient temperature if a value of 11 kcal/mole is assumed as the activation energy of the ageing process.
+
+### C.2 Apparatus
+
+The apparatus consists of a metallic container with vacuum tight valves that can be evacuated and filled with hydrogen gas. A pressure transducer continuously monitors the internal pressure.
+
+### C.3 Measurement procedures
+
+- Weigh the sample holder to an accuracy of 0.1 g.
+- Spread $100 \pm 1$ g of getter uniformly into the sample holder and re-weigh.
+- Insert the sample holder and seal the apparatus.
+- Degas for 24 h at less than 10 Pa.
+- Introduce hydrogen at 60 kPa.
+- After 24 h, note the hydrogen pressure and temperature.
+
+### C.4 Analysis
+
+The absorption of hydrogen is expressed as ml of hydrogen at STP per gramme of compound and is calculated from the following:
+
+$$\text{Hydrogen absorbed} = \frac{273(P - P_r)V}{1013(273 + T_r)M}$$
+
+where:
+
+$P$ is the initial pressure in 100 Pa
+
+$P_r$ is the hydrogen pressure after 24 h
+
+$T_r$ is the temperature (°C)
+
+$V$ is the volume of the apparatus (ml)
+
+$M$ is the getter weight in grammes
+
+## Appendix I
+
+### UK experience of hydrogen concentrations in moisture barrier optical fibre duct cables
+
+### I.1 Field experience
+
+There is practical experience to be drawn from more than $1 \times 10^6$ km of optical fibre installed in the United Kingdom since the late 1970s. The cables contain an aluminium laminate tape moisture barrier and many of the early cables were unfilled and pressurized. It has therefore been possible to measure the hydrogen concentration in cables installed for several years in ducts by monitoring drawn off gas from within the cables. The concentration of hydrogen was measured using a portable *Exhaled hydrogen monitor* described in Annex B. The peak value recorded for the hydrogen concentration in duct cables is 400 ppm (1). There have been no reports of any detectable rise in optical loss with such concentrations of hydrogen within the cables.
+
+### I.2 Analysis
+
+When solubility effects are ignored, the partial pressure of hydrogen within the moisture barrier screen is given by:
+
+$$P = \frac{H}{Q} \left[ 1 - \left( 1 - \frac{P_0 Q}{H} \right) \exp \left( - \frac{Q \cdot t}{V_0} \right) \right] \quad (1)$$
+
+where:
+
+- $P$ is the partial pressure of hydrogen (atm)
+- $P_0$ is the original partial pressure of hydrogen (atm)
+- $H$ is the hydrogen evolution rate (ml/cm · s)
+- $Q$ is the hydrogen escape rate through the barrier (ml/cm · s)
+- $t$ is the time in seconds
+- $V_0$ is the free volume per unit length of cable (ml/cm)
+
+Assuming that $H$ is not variable and the time constant $V_0/Q$ is short compared with the lifetime of the cable, the concentration of hydrogen within the cable for the service period will asymptotically tend to:
+
+$$P = \frac{H}{Q} \quad (2)$$
+
+as shown in Figure I.1.
+
+Considering a cable construction having a moisture barrier which consists of a longitudinal aluminium laminate tape applied with an overlap of at least 6 mm. The aluminium tape is coated on one side with polymer 40 µm thick. The heat of extrusion of the polyethylene sheath seals the overlap producing a 40 µm × 6 mm channel through which hydrogen can diffuse. This is the most significant route for hydrogen to escape since the diffusion through 150 µm of aluminium tape is very much slower.
+
+$Q$ can be measured directly. Nitrogen containing a known percentage of hydrogen is passed through cable samples, each surrounded by a sealed copper tube. The level of hydrogen is monitored as a function of time. By selecting a number of test samples of different length, it is possible to eliminate end effects and reduce the possibility of a freak defect in the construction of the overlap in a test sample.
+
+At 20 °C, the diffusion rate through the moisture barrier with a perfectly formed overlap is calculated to be:
+
+$$Q = 6.1 \times 10^{-10} \text{ ml/sec.atm.cm}$$
+
+As the overlap is not perfectly formed along the cable, the average value of the diffusion rate obtained from measurements is:
+
+$$Q = 3.7 \times 10^{-8} \text{ ml/sec.atm.cm}$$
+
+If the average temperature of installed cable is 5 °C, this average diffusion rate, when corrected to the field temperature, becomes:
+
+$$Q = 1.58 \times 10^{-8} \text{ ml/sec.atm.cm}$$
+
+The hydrogen evolution rate, which depends mainly on the hydrogen released by the corrosion of the aluminium tape, is determined from measurement to be:
+
+$$H = 1.5 \times 10^{-11} \text{ ml/sec.atm.cm}$$
+
+Substituting in Equation (2) gives the theoretical partial pressure of hydrogen to be:
+
+$$P = 1.5 \times 10^{-11} / 1.58 \times 10^{-8} = 949 \text{ ppm}$$
+
+The field value recorded of 400 ppm is much lower because there will always be some gas flow in a static pressurized system caused by leakage.
+
+
+
+T0603750-94/d04
+
+A graph showing the partial pressure of hydrogen (p) as a function of time (t) for a typical cable sample. The y-axis is labeled 'Partial pressure (p)' and the x-axis is labeled 'Time (t)'. The curve starts at the origin and rises to a horizontal asymptote labeled H/Q. The text T0603750-94/d04 is present in the bottom right corner of the graph area.
+
+**Figure I.1/L.27 – Partial pressure of hydrogen as a function of time for a typical cable sample**
+
+### I.3 References
+
+- HORNUNG (S.), CASSIDY (S.A.), REEVE (M.H.) The distribution of H2 gas along an inland optical fibre cable. Symposium of Optical Fibre Measurements 1984, *National Bureau of Standards*, NSB-SP-683, pp. 85-88, October 1984.
+
+## Appendix II
+
+## Japanese experience of the loss increase due to hydrogen generation in water-blocking tape optical fibre cable
+
+### II.1 Structure and materials of the water-blocking tape cable
+
+To assure the long-term stability of optical fibre cable characteristics, it is important to prevent water penetrating into the cable and hydrogen generation inside the cable. Water-blocking cable has been developed in which water-blocking tapes are wrapped around each slotted rod and also the cable core. Such cables are easy to manufacture and handle. The water-blocking tapes swell when they absorb water and form a kind of dam to prevent water penetration. Water can be stopped within 3 m of entry. Long-term stability with regard to optical loss increase requires checking because of the possible wetting of a short section of cable.
+
+A cross-section of the cable, given in Figure II.1, shows the slotted rods stranded around a central strength member. Each slotted rod is composed of a central steel wire embedded in polyethylene. Optical fibre ribbons are tightly inserted into each slot, and the rod is wrapped with water-blocking tape. A wrapping of water-blocking tape is applied to the laid-up rods and a polyethylene sheath is applied overall. All steel wires are covered with a thin coating of copper. The water-blocking tapes and the coatings of the optical fibre ribbons are made from materials which generate little hydrogen.
+
+### II.2 Hydrogen generated from cable components
+
+The amount of hydrogen generated by the ribbon coatings, the steel wires and the water-blocking tape were measured in accordance with Annex A. Both dry tapes and those which had absorbed artificial sea water were measured. The hydrogen generated for the different materials per cm2 at 80 °C is shown in Figure II.2.
+
+### II.3 Evaluation of loss increase due to hydrogen generation
+
+Optical loss increases due to hydrogen can be classified into two types:
+
+- that due to hydrogen molecules (H2 );
+- that due to hydroxyl (OH).
+
+The optical loss increase due to H2 is a reversible phenomenon and is proportional to the partial pressure of the hydrogen in the optical fibre cable. The quantity is given by
+
+$$L_{H_2} (\lambda) = C_{H_2} (\lambda) \cdot e^{2.24/RT} \cdot p \text{ (dB/km)} \quad (1)$$
+
+where:
+
+$R$ is the gas constant, with a value of $1.986 \times 10^{-3}$ (kcal/mol · °K)
+
+$T$ is the absolute temperature (°K)
+
+$p$ is the partial pressure of hydrogen in the cable
+
+$C_{H_2} (\lambda)$ is a coefficient dependent on wavelength and is the same for both single-mode and multimode optical fibres since it does not depend on dopant concentrations.
+
+The values of $C_{H_2} (\lambda)$ at 1.31 µm and 1.55 µm are estimated to be 0.0102 and 0.0195 respectively, making the loss increase at 1.55 µm nearly double that at 1.31 µm.
+
+Optical loss due to OH is irreversible and time dependent. The quantity $L_{OH} (\lambda)$ is given by
+
+$$L_{OH} (\lambda) = C_{OH} (\lambda) \cdot e^{-10.79/RT} \cdot p^{0.5} \cdot t^{0.38} \text{ (dB/km)} \quad (2)$$
+
+where:
+
+$t$ is the time in hours
+
+$C_{OH}(\lambda)$ is a coefficient dependent on wavelength and is different for single-mode and multimode fibres since it depends on dopant concentrations. The values at 1.31 $\mu\text{m}$ and 1.55 $\mu\text{m}$ for single-mode optical fibre are estimated to be $2.1 \times 10^4$ and $1.7 \times 10^5$ respectively.
+
+The partial pressure, $p$ , can be estimated from the volume of cable in which the hydrogen can diffuse and from the measurements of hydrogen generated in the cable components.
+
+The calculated increases in loss at room temperature for 20 years is summarized in Table II.1.
+
+**Table II.1/L.27 – Calculated increase in loss for single-mode optical fibre**
+
+| Wavelength | In air | | In water | |
+|------------|--------------------|--------------------|--------------------|--------------------|
+| | 1.31 $\mu\text{m}$ | 1.55 $\mu\text{m}$ | 1.31 $\mu\text{m}$ | 1.55 $\mu\text{m}$ |
+| $L_{H_2}$ | 0.0001 | 0.0003 | 0.0000 | 0.0001 |
+| $L_{OH}$ | 0.0005 | 0.0027 | 0.0002 | 0.0016 |
+| Total | 0.0006 | 0.0030 | 0.0002 | 0.0017 |
+
+The excess loss is estimated to be less than 0.005 dB/km at both 1.31 $\mu\text{m}$ and 1.55 $\mu\text{m}$ .
+
+### II.4 Increase in loss in water-penetrated cable
+
+In order to investigate the long-term stability of water-penetrated cable, water was pumped through a 50-m length of cable which was then held at 60 °C in a test chamber at 90% RH. Twenty fibres in a slot were spliced into a 1-km length. The results of optical loss measurement are shown in Figure II.3. No increase in loss at 1.24 $\mu\text{m}$ was detectable after five months. A reduction in loss at 1.55 $\mu\text{m}$ suggests some relaxation in the fibre packaging during this period.
+
+
+
+(Cable diameter: 40 mm)
+(Cable weight: 1.4 kg/m)
+
+Diagram of a 1000 fibre water-blocking optical fibre cable. The top part shows a cross-section of an 8-fibre ribbon with labels for 'Ribbon coating', 'Primary coating', and 'Single-mode optical fibre'. The bottom part shows a cross-section of the full cable with labels for '8-fibre ribbon', 'Water-blocking tape', 'Strength member', 'Slotted rod', 'Copper wire', and 'PE sheath'. Below the diagram, text indicates '(Cable diameter: 40 mm)' and '(Cable weight: 1.4 kg/m)'.
+
+T0603720-94/d05
+
+**Figure II.1/L.27 – 1000 fibre water-blocking optical fibre cable**
+
+
+
+Hydrogen (ml/cm2 , µl/cm)
+
+Measured at 80 °C
+
+Steel wire plated with Zn
+
+Optical fibre ribbon (µl/cm)
+
+Steel wire coated with copper
+
+Dry WB tape
+
+Wet WB tape
+
+Time (h)
+
+WB Water-Blocking
+
+T0603730-94/d06
+
+| Material | Time (h) | Hydrogen (ml/cm 2 , µl/cm) |
+|-------------------------------|----------|---------------------------------------|
+| Steel wire plated with Zn | 1 | 10 -3 |
+| Steel wire plated with Zn | 10 | 10 -2 |
+| Steel wire plated with Zn | 100 | 10 -1 |
+| Optical fibre ribbon | 10 | 10 -3 |
+| Optical fibre ribbon | 100 | 10 -2.5 |
+| Optical fibre ribbon | 1000 | 10 -2 |
+| Steel wire coated with copper | 1 | 10 -5 |
+| Steel wire coated with copper | 100 | 10 -5 |
+| Dry WB tape | 100 | 10 -6 |
+| Dry WB tape | 1000 | 10 -5 |
+| Wet WB tape | 100 | 10 -6.5 |
+| Wet WB tape | 1000 | 10 -6 |
+
+Log-log plot of Hydrogen generation (ml/cm², µl/cm) vs Time (h) for various cable materials at 80 °C. The y-axis ranges from 10⁻⁶ to 10⁻¹, and the x-axis ranges from 1 to 10³. Data series include: Steel wire plated with Zn (triangles), Optical fibre ribbon (crosses), Steel wire coated with copper (horizontal line), Dry WB tape (solid circles), and Wet WB tape (open circles).
+
+Figure II.2/L.27 – Hydrogen generated from various cable materials
+
+
+
+Loss change (dB/km)
+
+1.24 µm
+
+1.3 µm
+
+1.55 µm
+
+Time (month)
+
+T0603740-94/d07
+
+| Wavelength (µm) | Time (month) | Loss change (dB/km) |
+|-----------------|--------------|---------------------|
+| 1.24 | 0 | 0 |
+| 1.24 | 2 | 0 |
+| 1.24 | 5 | 0 |
+| 1.3 | 0 | 0 |
+| 1.3 | 2 | 0 |
+| 1.3 | 5 | 0 |
+| 1.55 | 0 | 0 |
+| 1.55 | 2 | -0.02 |
+| 1.55 | 5 | -0.05 |
+
+Linear plot of Loss change (dB/km) vs Time (month) for wet water-blocking cable at 60 °C and 90% RH. The y-axis ranges from -0.2 to 0.2, and the x-axis ranges from 0 to 6. Data series are shown for three wavelengths: 1.24 µm (triangles), 1.3 µm (circles), and 1.55 µm (squares).
+
+Figure II.3/L.27 – Change in loss of wet water-blocking cable at 60 °C and 90% RH
+
+## Appendix III
+
+## Spanish experience of hydrogen generation in moisture barrier optical fibre cables
+
+### III.1 Cable structure
+
+Between 1985 and 1990, Telefónica installed single-mode optical fibre cables which were constructed with a copolymer-aluminium moisture barrier and a stranded galvanized steel central strength member. All these cables were jelly-filled.
+
+### III.2 Field experience
+
+Even though our field experience showed us that for these cables hydrogen concentration is not important, we have in some cases found installed cables where the hydrogen concentration was sufficient to produce increases in attenuation on all fibres in the cable, both in the second and third transmission windows. The maximum measured increase of attenuation was 0.3 dB/km in the second window and 0.6 dB/km in the third window, corresponding to hydrogen partial pressure around 1 atm in the cable core.
+
+Figure III.1 shows the spectral attenuation of a fibre in a faulty cable (affected by hydrogen).
+
+### III.3 Origin of the problem
+
+After carrying out several tests, we concluded that the problem was due to the presence of water or humidity, within the cable, in contact with the galvanized steel strength member.
+
+The most probable hypothesis is that the cables were manufactured in bad conditions (with a high water or humidity content) or the galvanized steel was not adequately treated.
+
+### III.4 Problem solution
+
+A method to eliminate the hydrogen has been used with success in laboratory tests. The method consists on the connection of the galvanized steel strength member (in our case coated with polyethylene) to a dry air source at 5 atm pressure (see Figure III.2). After several weeks (between 2 and 8, depending on the cable length), the hydrogen level was reduced to insignificant values. Four months after the dry air had been disconnected, no new hydrogen generation had been detected.
+
+Figure III.3 shows the spectral attenuation decrease in a 1150-m length cable during the four weeks after connection to the dry air source.
+
+
+
+Graph of spectral attenuation (dB) versus wavelength (nm) for a 1920-m length of faulty cable. The y-axis scale is 3.00 dB/DIV. The x-axis ranges from START 1050.0 nm to STOP 1650.0 nm. The curve shows several peaks, with a prominent sharp peak around 1380 nm and smaller peaks at approximately 1240 nm, 1140 nm, and 1060 nm. The baseline attenuation is relatively flat between 1400 nm and 1600 nm.
+
+T0603950-96/d08
+
+**Figure III.1/L.27 – Spectral attenuation of a fibre in a 1920-m length of faulty cable (affected by hydrogen)**
+
+
+
+Schematic diagram of a cable connection to a dry air source. It shows a cross-section of an optical fibre (O.F. cable) with a polyethylene jacket. The jacket is connected to a dry air source via a fitting that includes a stranded central strength member. The dry air source is indicated by an arrow pointing towards the cable.
+
+T0603960-96/d09
+
+**Figure III.2/L.27 – Cable connection to the dry air source**
+
+
+
+Attenuation (dB/km)
+
+Initial measurement
+
+Final measurement
+
+Wavelength (nm)
+
+T0603970-96/d10
+
+Graph showing spectral attenuation (dB/km) versus wavelength (nm) for a 1150-m cable. The graph compares an 'Initial measurement' with a 'Final measurement' taken four weeks after the introduction of dry air. The initial measurement shows a sharp peak at approximately 1240 nm reaching nearly 10 dB/km. The final measurement shows a significantly reduced peak at the same wavelength, around 5 dB/km. Other smaller peaks are visible around 1170 nm and 1380 nm. The x-axis ranges from 1100 to 1500 nm, and the y-axis ranges from 0 to 11 dB/km. A small text label 'T0603970-96/d10' is present in the bottom right corner of the graph area.
+
+**Figure III.3/L.27 – Spectral attenuation decrease in a 1150-m cable during four weeks after the introduction of dry air**
+
+# ITU-T RECOMMENDATIONS SERIES
+
+- Series A Organization of the work of the ITU-T
+- Series B Means of expression: definitions, symbols, classification
+- Series C General telecommunication statistics
+- Series D General tariff principles
+- Series E Overall network operation, telephone service, service operation and human factors
+- Series F Non-telephone telecommunication services
+- Series G Transmission systems and media, digital systems and networks
+- Series H Audiovisual and multimedia systems
+- Series I Integrated services digital network
+- Series J Transmission of television, sound programme and other multimedia signals
+- Series K Protection against interference
+- Series L Construction, installation and protection of cables and other elements of outside plant**
+- Series M Maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits
+- Series N Maintenance: international sound programme and television transmission circuits
+- Series O Specifications of measuring equipment
+- Series P Telephone transmission quality, telephone installations, local line networks
+- Series Q Switching and signalling
+- Series R Telegraph transmission
+- Series S Telegraph services terminal equipment
+- Series T Terminals for telematic services
+- Series U Telegraph switching
+- Series V Data communication over the telephone network
+- Series X Data networks and open system communication
+- Series Z Programming languages
\ No newline at end of file
diff --git a/marked/L/T-REC-L.340-202306-I_PDF-E/raw.md b/marked/L/T-REC-L.340-202306-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..fb35ff36f550e1999549ecc4d6735b460045d1f0
--- /dev/null
+++ b/marked/L/T-REC-L.340-202306-I_PDF-E/raw.md
@@ -0,0 +1,511 @@
+
+
+# Recommendation
+
+## **ITU-T L.340 (06/2023)**
+
+SERIES L: Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant
+
+Maintenance and operation – Infrastructure maintenance
+
+---
+
+# **Maintenance of underground telecommunication facilities**
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue circular emblem with a stylized globe and the letters 'ITU' in white.
+
+ITU logo
+
+## ITU-T L-SERIES RECOMMENDATIONS
+
+### **Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant**
+
+| | |
+|--------------------------------------------------------|--------------------|
+| OPTICAL FIBRE CABLES | L.100-L.199 |
+| OPTICAL INFRASTRUCTURES | L.200-L.299 |
+| MAINTENANCE AND OPERATION | L.300-L.399 |
+| Optical fibre cable maintenance | L.300-L.329 |
+| Infrastructure maintenance | L.330-L.349 |
+| Operation support and infrastructure management | L.350-L.379 |
+| Disaster management | L.380-L.399 |
+| PASSIVE OPTICAL DEVICES | L.400-L.429 |
+| MARINIZED TERRESTRIAL CABLES | L.430-L.449 |
+| E-WASTE AND CIRCULAR ECONOMY | L.1000-L.1199 |
+| POWER FEEDING AND ENERGY STORAGE | L.1200-L.1299 |
+| ENERGY EFFICIENCY, SMART ENERGY AND GREEN DATA CENTRES | L.1300-L.1399 |
+| ASSESSMENT METHODOLOGIES OF ICTS AND CO2 TRAJECTORIES | L.1400-L.1499 |
+| ADAPTATION TO CLIMATE CHANGE | L.1500-L.1599 |
+| CIRCULAR AND SUSTAINABLE CITIES AND COMMUNITIES | L.1600-L.1699 |
+| LOW COST SUSTAINABLE INFRASTRUCTURE | L.1700-L.1799 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T L.340
+
+# Maintenance of underground telecommunication facilities
+
+## Summary
+
+Underground facilities, such as tunnels, maintenance holes and handholes, deteriorating continuously with time. For example, cracks and water leakages occur and these phenomena degrade the safety and serviceability of the underground facilities. If the deterioration is neglected, large-scale repair and reinforcement measures may be required, which will increase future costs. Therefore, it is highly recommended that periodic inspection and timely maintenance are performed.
+
+Safety management of telecommunication infrastructure facilities is described in general in ITU-T Recommendation L.330, but the detailed technologies and countermeasures for each facility are left for other Recommendations.
+
+Recommendation ITU-T L.340 describes the inspection procedures, technologies and countermeasures for the maintenance of underground facilities as defined in Recommendation ITU-T L.330.
+
+## History\*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|------------------|------------|-------------|--------------------|
+| 1.0 | ITU-T L.340/L.74 | 2008-04-06 | 6 | 11.1002/1000/9328 |
+| 2.0 | ITU-T L.340 | 2023-06-13 | 15 | 11.1002/1000/15558 |
+
+## Keywords
+
+Crack, deterioration, inspection, maintenance, underground facilities, water leakage.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2023
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|------------------------------------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 Maintenance of underground telecommunication facilities ..... | 3 |
+| 6.1 Inspection ..... | 3 |
+| 6.2 Inspection items..... | 3 |
+| 6.3 Inspection technologies ..... | 5 |
+| 6.4 Countermeasures ..... | 6 |
+| 6.5 Inspection work safety..... | 7 |
+| Appendix I – Experience with maintenance of cable tunnels in the Republic of Korea ..... | 8 |
+| I.1 Typical deterioration ..... | 8 |
+| I.2 Frequency of inspection ..... | 8 |
+| I.3 Typical inspection items..... | 9 |
+| I.4 Tunnel inspection by GPR..... | 11 |
+| Appendix II – Non-entry inspection of maintenance holes ..... | 13 |
+| II.1 Non-entry inspection of maintenance hole with capturing images ..... | 13 |
+| II.2 Non-entry inspection methods..... | 13 |
+
+
+
+# Recommendation ITU-T L.340
+
+# Maintenance of underground telecommunication facilities
+
+## 1 Scope
+
+This Recommendation describes detailed inspection technologies and countermeasures in case of deterioration of underground telecommunication facilities such as tunnels, maintenance holes and handholes. These inspection technologies and deterioration countermeasures are conducted when certain problems are identified during the regular inspection described in [ITU-T L.330]. This Recommendation covers:
+
+- inspection technologies for tunnels, maintenance holes and handholes;
+- countermeasures to prolong facility lifetime according to the inspection results;
+- maintenance procedures to realize safe and effective facility management.
+
+Appendix I provides the effective and quantitative maintenance technologies.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T L.330] Recommendation ITU-T L.330 (2020), *Telecommunication infrastructure facility management*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+- 3.1.1 **handhole** [ITU-T L.330]
+- 3.1.2 **maintenance hole (manhole)** [ITU-T L.330]
+- 3.1.3 **shield tunnel** [ITU-T L.330]
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+- 3.2.1 **concrete neutralization**: Carbonation of concrete by attack from atmospheric carbon dioxide will result in a reduction in alkalinity of the concrete and increase the risk of reinforcement corrosion.
+- 3.2.2 **corrosion**: Disintegration or deterioration of concrete or reinforcement by electrolysis or by chemical attack.
+- 3.2.3 **crack**: An incomplete separation into one or more parts with or without space in between. Cracks are classified by direction, width and depth. The following adjectives can be used: longitudinal, transverse, vertical, diagonal and random.
+
+**3.2.4 deterioration:** Deterioration is any adverse deviation from normal mechanical, physical and chemical properties either on the surface or in the whole body of concrete, generally through separation of its components.
+
+**3.2.5 disintegration:** Deterioration into small fragments or particles due to any cause.
+
+**3.2.6 distortion:** Any abnormal deformation of concrete from its original shape.
+
+**3.2.7 efflorescence:** A deposit of salts, usually white, formed on a surface indicating that a substance has emerged from below the surface.
+
+**3.2.8 erosion:** Deterioration brought about by the abrasive action of fluids or solids in motion.
+
+**3.2.9 honeycomb:** Voids left in concrete due to failure of the mortar to effectively fill the spaces among coarse aggregate particles.
+
+**3.2.10 inspection:** An examination of the soundness of a telecommunication infrastructure facility based on a comparison of the investigation, observation and measurement results to the appropriate judgement standards.
+
+NOTE – The inspection is conducted in order to grasp whether or not deformation is having an influence on the structural safety and durability, and then to take appropriate countermeasures to secure the infrastructure facility on the base of the evaluation results.
+
+**3.2.11 non-destructive testing (NDT):** Method used to detect defects such as cracks and corrosion that does not destroy the object under test.
+
+NOTE 1 – Non-destructive testing is also called non-destructive evaluation (NDE) or non-destructive inspection (NDI).
+
+NOTE 2 – Different methods of testing are available, such as the ultrasonic pulse velocity method and stress wave propagation method.
+
+**3.2.12 peeling:** A process in which thin flakes of mortar are broken away from an underlying concrete surface; such as by deterioration or by adherence of surface mortar to forms as they are removed.
+
+**3.2.13 pitting:** Development of relatively small cavities in a surface, due to phenomena such as corrosion or cavitation, or in concrete, localized disintegration.
+
+**3.2.14 popout:** The breaking away of small portions of a concrete surface due to internal pressure which leaves a shallow, typically conical, depression.
+
+**3.2.15 scaling:** Local flaking or peeling away of the near surface portion of concrete or mortar.
+
+**3.2.16 spall:** A fragment, usually in the shape of a flake, detached from a larger mass by a blow, by the action of weather, by pressure or by expansion within the large mass.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations:
+
+| | |
+|-----|----------------------------|
+| GPR | Ground Penetrating Radar |
+| NDE | Non-Destructive Evaluation |
+| NDI | Non-Destructive Inspection |
+| NDT | Non-Destructive Testing |
+
+# 5 Conventions
+
+None.
+
+# **6 Maintenance of underground telecommunication facilities**
+
+Like other public infrastructures such as bridges, roads and buildings, underground telecommunication facilities experience problems caused by cracks or water leakage as a result of deterioration of steel-reinforced concrete or the rebar itself. If such problems are left unrepaired, additional large-scale repair and reinforcement projects will probably be required, which will further increase the cost in the future. The purpose of maintenance is to detect the defects in underground facilities at an early stage and to take appropriate actions in order to enhance the facility durability and serviceability.
+
+## **6.1 Inspection**
+
+Irrespective of how well an underground facility is constructed, it will require preventive maintenance to preserve its integrity and to prolong its lifetime. Maintenance will necessarily require inspection and testing to determine the condition of the structures and to establish appropriate repair and maintenance measures. The inspection of underground facilities is performed to detect damage or defects that are detrimental to structural safety and durability. When crucial damage or defects are observed, they are to be evaluated by skilled experienced engineers, and then appropriate and prompt countermeasures, such as repair and reinforcement work, are taken. Inspections can be divided into periodic and precise inspections as described in clauses 6.1.1 and 6.1.2.
+
+#### **6.1.1 Periodic inspections**
+
+Periodic inspections, also called regular inspections usually involve visual assessments to check the status of the concrete surface such as cracks, water leaks or exposed rebar. At this stage, deformation is detected, and is evaluated as to whether or not precise inspections and/or temporary countermeasures are needed.
+
+It is recommended that procedures be established for the manager of the underground facilities to schedule/undertake periodic inspections. These inspections are mainly carried out by observing the surface of the underground facilities by visual inspection and measuring crack width with a crack gauge. The inspections are carried out using comprehensive identification sheets on which observations and measurements can be conveniently recorded.
+
+#### **6.1.2 Precise inspections**
+
+Precise inspections are carried out when the defects and/or deformations are deemed critical to the safety of the underground facilities. Quantitative measurements are also carried out when there is degradation that cannot be identified by visual inspection or when the cause of degradation must be clarified to judge whether countermeasures are needed and to select the optimum method. At this stage, a detailed investigation of the measurements and deformation detected in the periodic inspections is conducted by a specialist.
+
+These inspections may use destructive testing of a concrete sample and chemical analysis of a core sample to determine the degree of degradation. In addition, non-destructive testing (NDT) methods can be used to determine abnormalities, defects and voids.
+
+#### **6.1.3 Frequency of inspection**
+
+It is recommended that the frequency of inspection be determined by the type and current state of the underground facilities concerned, and the changes in the operating environment.
+
+### **6.2 Inspection items**
+
+#### **6.2.1 Typical inspection items for tunnels**
+
+Inspection items depend on the type of cable tunnel. Cable tunnels are generally divided into two types as follows:
+
+- Open-cut tunnel (rectangular cross-section or box type);
+- Shield tunnel (circular cross-section).
+
+An open-cut tunnel is constructed by a cut and cover method, and is made of steel-reinforced concrete. On the other hand, a shield tunnel is constructed by methods such as shield driving, boring, drilling and blasting, and jacked tunnelling. The cross-sections of these two types of cable tunnels are shown in Figure 1.
+
+
+
+The image contains two cross-sectional diagrams of cable tunnels. Diagram (a) represents an open-cut tunnel with a rectangular cross-section. It features a thick concrete frame with internal cable trays on both sides and a central walkway. An arrow labeled 'Reinforced concrete' points to the top slab. Diagram (b) represents a shield tunnel with a circular cross-section. It also features internal cable trays and a central walkway, but is enclosed within a circular 'Lining concrete' structure. An arrow labeled 'Lining concrete' points to the inner wall. Both diagrams are labeled 'a)' and 'b)' at the bottom, and the code 'L.340(23)' is present in the bottom right corner.
+
+Figure 1 shows two cross-sectional diagrams of cable tunnels. Diagram (a) shows an open-cut tunnel with a rectangular cross-section, labeled 'Reinforced concrete'. Diagram (b) shows a shield tunnel with a circular cross-section, labeled 'Lining concrete'. Both diagrams show internal cable trays and a central walkway.
+
+**Figure 1 – Typical types of cable tunnels: a) open-cut tunnel; and b) shield tunnel**
+
+Since the designs and construction procedures of these cable tunnels are different, they may experience different types of deterioration. Typical inspection items for tunnels are summarized in Table 1.
+
+**Table 1 – Typical inspection items for tunnels**
+
+| Facility type | Periodic inspection | Precise inspection |
+|-----------------|-----------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Open-cut tunnel | Cracks, water leakage; joint gap, offset; exposed rebar, length; surface damage; deformation. | Include periodic inspection items; buried depth of rebar; concrete neutralized depth; strength of concrete; concrete chloride content; corrosion of rebar, etc. |
+| Shield tunnel | Cracks in lining surface; water leakage; joint gap, offset; exposed rebar, length; surface damage; deformation. | Include periodic inspection items; heaving of tunnel bottom; settlement of tunnel bottom; cavities inside lining concrete; voids behind lining, etc. |
+
+#### 6.2.2 Typical inspection items for maintenance holes and handholes
+
+Inspection items are generally divided into the two main facility parts of concrete frame and cover. Typical inspection items for maintenance holes and handholes are summarized in Table 2.
+
+**Table 2 – Typical inspection items for maintenance holes and handholes**
+
+| Facility part | Periodic inspection | Precise inspection |
+|----------------|------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Concrete frame | Cracks; water leakage; exposed rebar, length; surface damage. | Include periodic inspection items; covering depth of rebar; concrete neutralized depth; strength of concrete; concrete chloride content, etc. |
+| Cover | Abrasion; crack; rattle; level difference. | None. |
+
+## 6.3 Inspection technologies
+
+Inspection technologies commonly used for underground telecommunication facilities mainly consist of visual inspection and NDT methods. When a defect is found during visual inspection, its cause is then established and its size and condition are investigated in detail. Since cracks are among the critical inspection items, it is recommended to measure a crack's width and depth using a crack gauge, and to check whether or not the cracks are propagating. Table 3 summarizes typical inspection technologies including NDT methods.
+
+**Table 3 – Typical inspection technologies**
+
+| Typical inspection items | Technologies | Descriptions |
+|------------------------------------------------------------------------------------------------|-------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Cracks, water leakage, joint gap, exposed rebar, surface damage, abrasion and level difference | Visual inspection (Note 1) | Visual inspection results are recorded as a sketch or digital image. Crack width and joint gap can be measured by crack gauge with magnifier. Abrasion and level difference can be measured by caliper. |
+| Concrete neutralized depth | Phenolphthalein indicator | Core cut from hardened concrete is sprayed with phenolphthalein indicator, and then a purple-red coloration will appear where alkaline concrete has been unaffected by carbonation; no coloration will appear in carbonation zones. |
+| Voids, water leakage | Infrared thermography (Note 2) | This method measures the thermal radiation emitted by a tunnel's walls or concrete frame, and can identify defects in the lining and voids. Infrared techniques allow visual presentation of the temperature distribution on the surface. |
+| Strength of concrete | Testing of cores | This is a well-established method. Cores are cut from hardened concrete by a core drill, and compressive testing is performed. |
+| | Surface hardness method (Note 2) | This test is based on the principle that the rebound of an elastic mass depends on the hardness of the surface. The results give a measure of the relative hardness of this zone, and there is a close correlation between rebound number and compressive strength of the concrete. |
+| | Ultrasonic pulse velocity method (Note 2) | This method injects ultrasonic waves into concrete to analyse its internal state by detecting the wave transmitted and reflected by substances with different elastic properties in the concrete wall. This method can identify structural |
+
+**Table 3 – Typical inspection technologies**
+
+| Typical inspection items | Technologies | Descriptions |
+|--------------------------------|-----------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | abnormalities such as cracks, thickness variations and degradation in compressive strength. |
+| Defects inside lining concrete | Stress wave propagation method (Note 2) | This method is based on the use of impact-generated stress waves that propagate through concrete and are reflected by internal flaws and external surfaces. This method can be used to determine the location and extent of flaws such as cracks and voids. |
+| Voids inside lining concrete | Ground penetrating radar (GPR) (Note 2) | This is a geophysical method that uses radar pulses to image the subsurface. This method uses electromagnetic radiation, and detects the reflected signals from subsurface structures. GPR uses transmitting and receiving antennas. The transmitting antenna radiates short pulses of high-frequency (usually polarized) radio waves into the ground. When the wave hits a buried object or a boundary with different dielectric constants, the receiving antenna records variations in the reflected return signal. The depth range of GPR is limited by the electrical conductivity of the ground, and the transmitting frequency. Higher frequencies do not penetrate as far as lower frequencies, but give better resolution. The wave frequencies are between 900 and 2 000 MHz. This method can identify structural abnormalities such as voids, thickness variations and interface voids between the lining and the ground in a cable tunnel. |
+
+NOTE 1 – Visual inspection can be replaced by non-entry inspection using remote cameras.
+
+NOTE 2 – NDE technologies.
+
+### 6.4 Countermeasures
+
+Once the inspection of the underground facility is complete, the repair and reinforcement plans are established. Judgement of repair and reinforcement depends on the evaluation of the field inspection results. The repair of crack, water leakage and other types of deterioration should consider the safety, durability and serviceability of the underground facility.
+
+#### 6.4.1 Countermeasures against cracks
+
+Cracks are the most typical and important types of deterioration to be considered. Cracks, however, have many causes and so the types vary. In general, cracks that may happen in underground facilities are categorized as follows:
+
+- Crack with no water;
+- Crack with some moisture;
+- Crack with water leakage;
+- Crack accompanying the corrosion of rebar;
+- Joint crack.
+
+Three width ranges are typically suggested as follows:
+
+- Fine: Generally less than 1 mm;
+- Medium: Between 1 and 2 mm;
+- Wide: Over 2 mm.
+
+It is recommended that cracks be repaired for safety, durability and serviceability. When a crack is detected, it is important to precisely know its cause or causes. Whether the crack should be repaired or not is to be decided by a qualified engineer.
+
+#### **6.4.2 Countermeasures against water leakage**
+
+The corrosion of rebar in concrete is accelerated by water leakage. The concrete surface and steel accessories in an underground facility are also degraded by toxic or polluted water. Various techniques have been developed as countermeasures against water leakage, but there are many cases in which water leakage reoccurs after construction. Therefore, it is necessary to select countermeasures after carefully considering their effectiveness, workability, cost and durability.
+
+### **6.5 Inspection work safety**
+
+For the tunnel inspection work, a sign that the work is being carried out should be displayed at the entrance of the tunnel. For the maintenance hole and handhole inspection work, a safety fence should be installed to prevent outsiders from entering the work area. In addition, toxic gases such as carbon monoxide may accumulate in underground facilities. Prior to commencing tunnel inspection, workers should confirm the normal operation of the ventilator before entering the tunnel. In maintenance hole inspection, adequate ventilation should be assured, and a toxic gas detector should be used before entering the maintenance hole.
+
+## Appendix I
+
+### Experience with maintenance of cable tunnels in the Republic of Korea
+
+(This appendix does not form an integral part of this Recommendation)
+
+### I.1 Typical deterioration
+
+Typical types of deterioration that may happen in a cable tunnel are cracks, water leakage and the corrosion of rebar. Figure I.1(a) shows cracks with water leakage and efflorescence that occurred in a box type cable tunnel; Figure I.1(b) shows joint cracks with water leakage in a shield type cable tunnel; and Figure I.1(c) shows exposed steel and the corrosion of rebar on the ceiling of a box type cable tunnel. These defects degrade the safety, durability and serviceability of the cable tunnel.
+
+
+
+Figure I.1 consists of three sub-images labeled (a), (b), and (c). Image (a) shows a concrete ceiling with a horizontal crack and some water leakage. Image (b) shows a joint between two concrete segments with a vertical crack and water leakage. Image (c) shows a close-up of a rebar that has been exposed and is corroded, with some concrete missing around it.
+
+Figure I.1 shows three images of cable tunnel deterioration: (a) cracks and water leakage in a box type tunnel; (b) joint cracks and water leakage in a shield type tunnel; (c) exposed steel and corrosion of rebar on the ceiling of a box type tunnel.
+
+**Figure I.1 – Typical types of deterioration: (a) cracks; (b) water leakage; and (c) corrosion of rebar**
+
+### I.2 Frequency of inspection
+
+Inspections are to be performed by a specialist or a qualified engineer with experience in the design and construction of cable tunnels. The time, frequency and method of inspection are determined according to the type of cable tunnel. Inspections are performed at two different stages: 1) periodic inspection; and 2) precise inspection. Periodic inspection includes periodic routine inspections that are performed at an interval of not more than a month or year. Most defects are detected, recorded and evaluated at this stage. When a defect that is considered to affect the safety of a cable tunnel is detected, an emergency inspection is carried out. Precise inspection is also done at an interval of five years. Table I.1 describes the frequency of inspection.
+
+**Table I.1 – Frequency of inspection**
+
+| Inspection | | Frequency | Inspector |
+|---------------------|-----------------------------|----------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------|
+| Periodic inspection | Periodic routine inspection | Every month Every year | Manager of cable tunnel |
+| | Periodic inspection | Every two years | Specialist or a qualified engineer in the firm |
+| | Emergency inspection | When a critical defect is detected, or a cable tunnel is in danger | Specialist or a qualified engineer in the firm |
+| Precise inspection | | When a critical defect is detected, or a cable tunnel is in danger When 10 years have passed after construction Every five years | Specialist in safety, durability and serviceability |
+
+### **I.3 Typical inspection items**
+
+The inspection is carried out using comprehensive identification sheets on which observations and measurements can be conveniently recorded. Two examples of routine monitoring sheet for box type and shield type cable tunnels are shown in Tables I.2 and I.3, respectively.
+
+**Table I.2 – Example of a routine monitoring sheet for box type cable tunnel**
+
+| | | | | |
+|----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|------------|------------|
+| Cable tunnel name: Inspection site: | | Date: Inspector name: | | |
+| Inspection items | Description | Location | | |
+| | | Left wall | Upper slab | Right wall |
+| Crack | Crack width: mm Crack length: cm Is crack progressive? YES ( ), NO ( ) | | | |
+| Water leakage | Crack width with water leakage: mm Severity of water leakage: wet ( ), dripping ( ), flowing ( ) Extent of water leakage: few ( ), intermittent ( ), frequent ( ), extensive ( ) Efflorescence: | | | |
+| Exposed steel | Severity of steel corrosion: very slight ( ), slight ( ), moderate ( ), severe ( ), very severe ( ) Extent of steel exposure: few ( ), intermittent ( ), frequent ( ), extensive ( ) | | | |
+| Concrete neutralized | Concrete neutralized depth, if any: mm | | | |
+| Facilities in cable tunnel | Condition of light: good ( ), moderate ( ), fix needed ( ) Condition of water pump: good ( ), moderate ( ), fix needed ( ) Condition of ventilation: good ( ), moderate ( ), fix needed ( ) | | | |
+
+**Table I.2 – Example of a routine monitoring sheet for box type cable tunnel**
+
+| | | | | |
+|------------------------------|---------------------------|--|--|--|
+| Remarks | (Describe what is needed) | | | |
+| Photograph or sketch of site | | | | |
+
+**Table I.3 – Example of a routine monitoring sheet for shield type cable tunnel**
+
+
+
+Cross-section diagram of a shield type cable tunnel. It shows a circular tunnel with a central line (CL) at the top, side lines (SL) on the left and right, and floor lines (FL) at the bottom. Inside the tunnel, there are two vertical structures with horizontal lines representing cracks or joints. The diagram is labeled L.340(23) at the bottom right.
+
+| | | |
+|----------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|
+| Cable tunnel name: Inspection site: | | Date: Inspector name: |
+| Inspection items | Descriptions | |
+| Crack | Crack width: mm Crack length: cm Is crack progressing? YES ( ), NO ( ) | |
+| Water leakage | Crack width with water leakage: mm Severity of water leakage: wet ( ), dripping ( ), flowing ( ) Extent of water leakage: few ( ), intermittent ( ), frequent ( ), extensive ( ) Efflorescence: | |
+| Exposed rebar | Severity of rebar corrosion: very slight ( ), slight ( ), moderate ( ), severe ( ), very severe ( ) Extent of steel exposure: few ( ), intermittent ( ), frequent ( ), extensive ( ) | |
+
+**Table I.3 – Example of a routine monitoring sheet for shield type cable tunnel**
+
+| | |
+|-------------------------|-------------------------------------------------------------------------------------------------|
+| Contamination of lining | Extent of contamination: few ( ), intermittent ( ), frequent ( ), extensive ( ), throughout ( ) |
+| Heaving of bottom | Severity of heaving: very slight ( ), slight ( ), moderate ( ), severe ( ), very severe ( ) |
+| Deformation of lining | Severity of deformation: very slight ( ), slight ( ), moderate ( ), severe ( ), very severe ( ) |
+
+
+
+Section number 1 2 3 4 5 6 7 8 9 10
+
+FL
+
+SL
+
+CL
+
+SL
+
+FL
+
+— Crack Exposed steel Water leakage
+
+FL: Foot line SL: Side line CL: Ceiling line
+
+L.340(23)
+
+**Figure I.2 – Unfolded map of cable tunnel**
+
+Figure I.2 – Unfolded map of cable tunnel. A diagram showing a linear representation of a tunnel divided into 10 sections. The vertical axis marks the Foot line (FL), Side line (SL), and Ceiling line (CL). Defects are indicated by symbols: cracks (thin lines), exposed steel (hatched ovals), and water leakage (dotted ovals). Water leakage is shown in sections 1 and 8. Exposed steel is shown in section 8. Cracks are shown in sections 2, 3, 4, 5, 6, 7, and 9. A legend at the bottom defines the symbols and lines. The code L.340(23) is noted in the bottom right. Exposed steel symbol Water leakage symbol
+
+### I.4 Tunnel inspection by GPR
+
+It has been found that the typical defects of cable tunnels are cracks, water leakage, voids, spalling and heaving as shown in Figure I.3. Among them, it is known that voids behind lining concrete are most detrimental to the safety of tunnels.
+
+
+
+A cross-sectional diagram of a circular tunnel. The outer ring is labeled 'Lining concrete'. Various defects are indicated with arrows and labels: 'Void' at the top, 'Spall' and 'Crack' on the upper left outer edge, 'Efflorescence' on the lower left outer edge, 'Crack' on the upper right inner edge, 'Water leakage' on the right outer edge, and 'Heaving' at the bottom inner edge. The label 'L.340(23)' is at the bottom right.
+
+Diagram of a cable tunnel cross-section showing various defects.
+
+**Figure I.3 – Defects that may happen in a cable tunnel**
+
+To detect voids, GPR is applied as shown in Figure I.4. The internal image can be acquired continuously as the antenna moves along the surface of the lining concrete. Structural abnormalities such as voids, thickness variations and interface voids between the lining and the ground can be detected.
+
+
+
+A photograph showing two people inside a tunnel. One person is operating a Ground Penetrating Radar (GPR) unit, which consists of a wheeled cart with a control screen and a sensor antenna being pushed against the tunnel wall. The other person stands behind them, possibly monitoring the data. The tunnel has a series of vertical ribs or supports.
+
+Photograph of two people using GPR equipment inside a tunnel.
+
+**Figure I.4 – Tunnel lining inspection using GPR**
+
+## Appendix II
+
+### Non-entry inspection of maintenance holes
+
+(This appendix does not form an integral part of this Recommendation)
+
+### II.1 Non-entry inspection of maintenance hole with capturing images
+
+Convention inspection of the concrete frame of maintenance hole requires the worker to enter the maintenance hole, conduct a visual inspection and record a sketch. However, the conventional method has issues in terms of work efficiency, such as the necessity of safety measures before entering the maintenance hole and the time required for pumping out the condensation water and ventilating the hole. In addition, in order to improve the efficiency of future facility inspections, it is necessary to analyse the degree of deterioration of maintenance holes over time from the periodic inspection data, and to accumulate a large amount of digital data that is not dependent on worker skill. Therefore, focusing on the fact that cracks and exposed rebars, which are typical (and initial) surface defects in reinforced concrete structures, we can introduce a non-entry inspection method that captures high resolution images of the upper plate in periodic inspection. Thus, the pumping out time of the condensation water is shortened, ventilation is not required and efficient and constant quality inspection of the concrete frame can be performed.
+
+### II.2 Non-entry inspection methods
+
+The non-entry inspection method focuses on grasping the state of the upper plate surface. There are two main types of camera for capturing the inspection images needed. One is the direct type in which the concrete frame surface is partially photographed in the vicinity of the plate, and a camera connected to a robot arm scans the plate. An inspection image of a plate is obtained by merging several images. The second type is an autonomous camera drone which flies inside the maintenance hole and captures images without distortion. In every case, the images taken inside the maintenance hole can be confirmed on a tablet device by communication links such as Wi-Fi. If it is required to check inside accessories placed on a concrete surface other than the upper plate, omni-directional cameras can be adopted as the third method. Omni-directional cameras using a fisheye lens can capture the whole inside surface. Although it takes time to pump up the condensation water, an image containing all plates and accessories is obtained after distortion correction in one pass. Figures and details of these three methods are given in Figure II.1 and Table II.1, respectively.
+
+
+
+Figure II.1: Non-entry inspection methods. The figure consists of three sub-diagrams labeled a), b), and c). Diagram a) shows a 'Wide-angle camera' mounted on an 'Arm' and 'Fixture' on the 'Road surface' next to the 'Upper plate' of a 'Concrete frame'. A shaded area indicates the 'Angle of view'. Diagram b) shows a 'Camera on drone' flying along a 'Flight route' inside the 'Concrete frame' to inspect the 'Upper plate'. Diagram c) shows an 'Omni-directional camera' mounted on an 'Arm' and 'Fixture' on the 'Road surface' next to the 'Upper plate' of a 'Concrete frame', with a wide, circular 'Angle of view' covering the interior. A legend at the bottom left shows a shaded box for 'Angle of view'. The text 'L.340(23)' is in the bottom right corner.
+
+**Figure II.1 – Non-entry inspection methods, a) direct type; b) camera drone; c) omni-directional type**
+
+**Table II.1 –Features of cameras for capturing inspection image**
+
+| Type | Advantages | Disadvantages |
+|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Direct type | – Capable of photographing details of defects such as cracks and exposed rebars | – Requires multiple camera images – Difficult to apply to deeper maintenance holes |
+| Camera drone | – Capable of photographing details of defects such as cracks and exposed rebars – Applicable regardless of depth and width of maintenance hole | – Measures to meet flight regulations may need to be taken (e.g., dense urban area) |
+| Omni-directional type | – Photographing the whole inside surface of the maintenance hole in one pass – Applicable regardless of depth of maintenance hole | – Distortion of the image makes it difficult to measure the absolute width of cracks – Images around large manholes are blurred – All condensation is pumped out to photograph all inside surfaces |
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|----------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.37-200702-I_PDF-E/7affafe7362a2d2d072e9d4bf515f0bb_img.jpg b/marked/L/T-REC-L.37-200702-I_PDF-E/7affafe7362a2d2d072e9d4bf515f0bb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..12489e7a40e67824cef6494a22a4a78dc3d0d3a2
--- /dev/null
+++ b/marked/L/T-REC-L.37-200702-I_PDF-E/7affafe7362a2d2d072e9d4bf515f0bb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9249dadbc563b9e725b5a7fb6b7399a3acc6c43aff1d469b526ae4d3591fc4f0
+size 21156
diff --git a/marked/L/T-REC-L.37-200702-I_PDF-E/dd0f5301a5a6dd7c319701302110de88_img.jpg b/marked/L/T-REC-L.37-200702-I_PDF-E/dd0f5301a5a6dd7c319701302110de88_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..42275bcb6cd94c52ef05ed1ca73b1177697c2ac2
--- /dev/null
+++ b/marked/L/T-REC-L.37-200702-I_PDF-E/dd0f5301a5a6dd7c319701302110de88_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c39361b093bee50fb8f7d9ed725bc1519059eaee8cafd1ca622e371cd881e6b4
+size 28033
diff --git a/marked/L/T-REC-L.37-200702-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg b/marked/L/T-REC-L.37-200702-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..36cf51f8ba07e44aa7a4b009f3ba08eb2b570b1c
--- /dev/null
+++ b/marked/L/T-REC-L.37-200702-I_PDF-E/e8ba5d4a3a22e24e44f7935ea26afcb0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11780faeee75ba39ab4ed9de67a9e67abec0d9ba3068ebec661dea70c16e29d3
+size 4338
diff --git a/marked/L/T-REC-L.37-200702-I_PDF-E/ff2492be4fa814905acbad18f261b8a5_img.jpg b/marked/L/T-REC-L.37-200702-I_PDF-E/ff2492be4fa814905acbad18f261b8a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f78f86a382c7785c145d091c3a03ad6e2f9c8f0d
--- /dev/null
+++ b/marked/L/T-REC-L.37-200702-I_PDF-E/ff2492be4fa814905acbad18f261b8a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b48a5fdae3cb5d3baf38602d86aa81667b07b8e280a661607bd870749d32e591
+size 26158
diff --git a/marked/L/T-REC-L.37-200702-I_PDF-E/raw.md b/marked/L/T-REC-L.37-200702-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..c09cd08bab9a5612b27a9bc499c654e6a4b0abb3
--- /dev/null
+++ b/marked/L/T-REC-L.37-200702-I_PDF-E/raw.md
@@ -0,0 +1,532 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.37**
+
+(02/2007)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Optical branching components (non-wavelength
+selective)**
+
+ITU-T Recommendation L.37
+
+
+
+# **ITU-T Recommendation L.37**
+
+# **Optical branching components (non-wavelength selective)**
+
+## **Summary**
+
+ITU-T Recommendation L.37 describes the main features of fibre-optic branching devices in terms of types, fields of application, configurations and technical aspects.
+
+Furthermore, ITU-T Recommendation L.37 describes the requirements of the mechanical, environmental and physical performance and reliability for optical branching components, which are stipulated in ITU-T Recommendation G.671 with regard to the optical performance of PONs, advising on general requirements and test methods.
+
+## **Source**
+
+ITU-T Recommendation L.37 was approved on 22 February 2007 by ITU-T Study Group 6 (2005-2008) under the ITU-T Recommendation A.8 procedure.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2007
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 2 |
+| 6 General information..... | 2 |
+| 7 Types and configurations..... | 2 |
+| 8 Technological aspects..... | 3 |
+| 9 Optical parameters and performance ..... | 3 |
+| 10 Application environments and test methods for optical branching components..... | 3 |
+| 10.1 Application environments ..... | 4 |
+| 10.2 Performance and reliability test methods ..... | 4 |
+| Appendix I – Optional performance requirement ..... | 9 |
+| I.1 Low temperature storage ..... | 9 |
+| Appendix II – Additional criteria for performance and reliability tests for optical branching components for PONs..... | 10 |
+| II.1 Introduction ..... | 10 |
+| II.2 Criteria for performance and reliability tests for optical branching components for PONs..... | 10 |
+
+
+
+## Optical branching components (non-wavelength selective)
+
+# 1 Scope
+
+This Recommendation applies to optical branching components (non-wavelength selective) to be used for passive optical networks (PONs).
+
+This Recommendation:
+
+- gives general information on fundamental types of optical branching components, and their field of application;
+- classifies optical branching components into types and configurations;
+- provides a general description of the basic operating principle and the fabrication technologies;
+- describes the application environments of optical branching components for PONs;
+- reports the performance and outlines reliability test methods for optical branching components for PONs.
+
+NOTE – Performance and reliability requirements in this Recommendation relate only to the properties of the optical branching component. This does not include the behaviour of optical connectors that may be used to terminate input and/or output fibres.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T G.671] ITU-T Recommendation G.671 (2005), *Transmission characteristics of optical components and subsystems*, plus Amendment 1 (2006).
+- [ITU-T G.983.1] ITU-T Recommendation G.983.1 (2005), *Broadband optical access systems based on Passive Optical Networks (PON)*.
+- [ITU-T G.983.3] ITU-T Recommendation G.983.3 (2001), *A broadband optical access system with increased service capability by wavelength allocation*.
+- [ITU-T G.984.2] ITU-T Recommendation G.984.2 (2003), *Gigabit-capable Passive Optical Networks (G-PON): Physical Media Dependent (PMD) layer specification*.
+- [IEC 60695-11-10] IEC 60695-11-10 (2003), *Fire hazard testing – Part 11-10: Test flames – 50 W horizontal and vertical flame test methods*.
+- [IEC 61300] IEC 61300-series, *Fibre optic interconnecting devices and passive components – Basic test and measurement procedures*.
+- [IEC 62005-2] IEC 62005-2 (2001), *Reliability of fibre optic interconnecting devices and passive components – Part 2: Quantitative assessment of reliability based on accelerated ageing test – Temperature and humidity; steady state*.
+
+# 3 Definitions
+
+This Recommendation defines the following term:
+
+**3.1 optical branching component:** A passive optical component with three or more ports that shares optical power among its ports in a predetermined fashion, without any amplification, switching or other active modulation.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|---------------------------------------------------------------------|
+| CVD | Chemical Vapour Deposition |
+| FBT | Fused Biconic Taper |
+| FHD | Flame Hydrolysis Deposition |
+| FIT | Failures In Time (number of device failures in $10^9$ device hours) |
+| OLT | Optical Line Termination |
+| ONU | Optical Network Unit |
+| PON | Passive Optical Network |
+
+# 5 Conventions
+
+*None.*
+
+# 6 General information
+
+Optical branching components provide a method for splitting optical signals between M input and N output ports (see Figure 6-1); optical branching components are required when an optical signal has to be split into two or more fibre lines or when several signals coming from different fibre lines have to be mixed in a single fibre line; in general, optical branching components are dividers/combiners of transit signals.
+
+
+
+Schematic diagram of an MxN optical branching component. A central rectangular box represents the component. On the left, M input ports are shown, indicated by a bracket labeled 'M' and a vertical dashed line. On the right, N output ports are shown, indicated by a bracket labeled 'N' and a vertical dashed line. Dashed lines represent optical paths connecting each of the M inputs to each of the N outputs, illustrating a fully connected mesh. The diagram is labeled 'Input' on the left, 'Output' on the right, and 'L.37(07)\_F01' at the bottom right.
+
+**Figure 6-1 – MxN branching component (schematic)**
+
+In a point-to-multipoint distribution architecture, optical branching components are used to connect an OLT located at a central office to several ONUs located in outside plant or on subscriber premises.
+
+# 7 Types and configurations
+
+Optical branching components can be classified as one or more of the following:
+
+- star branching devices:** A branching device typically balanced; possessing more than four ports;
+
+- b) **tree branching devices:** A branching device with a single optical input distributed among several outputs, or vice versa.
+
+Optical branching components can be designed to operate at a single wavelength (e.g., 1310 or 1550 nm), to be wavelength flat (e.g., insensitive to wavelength variations within a single window) or to be wavelength independent (e.g., insensitive to wavelength variations within both the second and third windows, 1260-1360 nm and 1450-1600 nm, or 1260-1360 nm and 1450-1660 nm).
+
+# 8 Technological aspects
+
+There are several methods used to manufacture optical branching components, and they can be grouped into the following classes:
+
+- a) **fusion technology:** This technology has proved to be simple, versatile and effective, allowing the industrial implementation of several kinds of branching devices for a variety of applications. With the fused biconic taper (FBT) method, bare or etched fibres are brought into contact, stretched, possibly twisted, and fused so that evanescent mode coupling occurs along the interaction length;
+- b) **planar optics technology:** Planar waveguide branching devices are made by photolithographic technology, using parallel processing techniques. To produce the refractive index profile, ions are diffused into a substrate such as glass, semiconductor (silicon), $\text{LiNbO}_3$ or polymer. Alternatively, doped silica glass is fabricated by chemical vapour deposition (CVD) or by flame hydrolysis deposition (FHD) and consolidation. The optical profile and the geometrical properties of the guiding structure are defined by photolithographic masking techniques followed by etching;
+- c) **polishing technology:** In order to position fibre cores close enough to allow the overlap of the evanescent fields (coupling conditions), the fibre cladding is removed to within a few microns of the core. This controlled removal of the cladding is achieved by mechanical abrasion (polishing).
+
+# 9 Optical parameters and performance
+
+Optical branching components for PONs are characterized by several parameters, the most important of which are the following:
+
+- insertion loss;
+- reflectance;
+- optical wavelength range;
+- polarization-dependent loss.
+- directivity;
+- uniformity.
+
+These parameters are defined in Amendment 1 to [ITU-T G.671].
+
+# 10 Application environments and test methods for optical branching components
+
+The following describes application environments, and performance and reliability test methods for optical branching components for PONs.
+
+During or after each test, the device should still meet loss criteria according to Amendment 1 to [ITU-T G.671].
+
+Insertion loss measurements should be executed at least at 1310 and 1550 nm, but also at 1625 nm if agreed between user and supplier.
+
+## **10.1 Application environments**
+
+The recommended temperature range in which the performance should be guaranteed is from $-40^{\circ}\text{C}$ up to at least $+75^{\circ}\text{C}$ (for applications in passive nodes).
+
+The recommended humidity range in which the performance should be guaranteed is from 5% to 95% RH.
+
+## **10.2 Performance and reliability test methods**
+
+### **10.2.1 Basic performance requirements**
+
+These requirements apply to all splitters to assess their performance.
+
+#### **10.2.1.1 Vibration**
+
+The test procedure should be in accordance with [IEC 61300], part 2-1, and insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Frequency range: 10-55 Hz.
+- Sweep rate: to vary uniformly between 10 and 55 Hz and to return to 10 Hz in approximately 4 min.
+- Endurance duration per axis: at least 20 minutes in each of three mutually perpendicular planes.
+- Number of axes: 3.
+- Vibration amplitude: 1.52 mm.
+
+##### **10.2.1.2 Impact**
+
+The test procedure should be in accordance with [IEC 61300], part 2-9, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Peak acceleration and duration: 500 g; 1 ms pulse duration.
+- Number of impacts per direction: 5.
+- Number of axes: 3 (two directions per axis).
+
+#### **10.2.1.3 Fibre retention**
+
+The test procedure should be in accordance with [IEC 61300], part 2-4, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Magnitude of the load: 5 N for coated fibres (primary and secondary), 10 N for 4-fibre ribbon.
+- Load rate: 400 $\mu\text{m/s}$ for coated fibres until attaining the maximum load.
+- Point of application of the tensile load: minimum 0.1 m from the end of the fibre.
+- Duration of the test: 1 min while maintaining the load.
+
+#### **10.2.1.4 Fibre side pull**
+
+The test procedure should be in accordance with [IEC 61300], part 2-42, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Magnitude of the load: 2.5 N for single fibre/5 N for ribbon fibre or loose tube.
+- Angle of application to interface: $90^{\circ}$ .
+- Duration of the load application: 5 s.
+- Number of mutually perpendicular directions of load application: 2.
+- Point of application of the load: 22 to 28 cm from the component housing.
+
+#### 10.2.1.5 Temperature humidity cycle
+
+The test procedure should be in accordance with [IEC 61300], part 2-48, and the insertion loss measurements are performed before, during and after this test. The test parameter values are as follows (see Figure 10-1):
+
+- Temperature range: $-40$ to $+75^{\circ}\text{C}$ .
+- Humidity range: 10 to 80% RH.
+- Thermal profile:
+ - from 2 to $32^{\circ}\text{C}$ , maintain a constant relative humidity of $80 \pm 2\%$ ;
+ - from 32 to $75^{\circ}\text{C}$ , maintain a constant humidity ratio from 80% RH at $32^{\circ}\text{C}$ to 10% RH at $75^{\circ}\text{C}$ ;
+ - below $2^{\circ}\text{C}$ , humidity is uncontrolled.
+- Minimum duration at extreme temperature: 1 hour.
+- Temperature rate of change: $1^{\circ}\text{C}/\text{min}$ .
+- Number of cycles: 42 (8 h/cycle).
+
+
+
+| Time (hours) | Temperature (degrees Celsius) |
+|--------------|-------------------------------|
+| 0 | 21 |
+| 1 | 21 |
+| 2 | 75 |
+| 3 | 75 |
+| 4 | 21 |
+| 5 | 21 |
+| 6 | -40 |
+| 7 | -40 |
+| 8 | 21 |
+| 9 | 21 |
+| 10 | 75 |
+| 11 | 75 |
+| 12 | 21 |
+
+Figure 10-1: Thermal profile of temperature humidity cycle test. The graph shows temperature (degrees Celsius) on the y-axis (from -40 to +75) versus time (hours) on the x-axis (from 0 to 12). The profile starts at 21°C at 0 hours, ramps up to 75°C at 2 hours, holds at 75°C until 3 hours, ramps down to 21°C at 4 hours, holds at 21°C until 5 hours, ramps down to -40°C at 6 hours, holds at -40°C until 7 hours, ramps up to 21°C at 8 hours, holds at 21°C until 9 hours, ramps up to 75°C at 10 hours, holds at 75°C until 11 hours, and ramps down to 21°C at 12 hours. The label 'L.37(07)\_F02' is in the bottom right corner.
+
+Figure 10-1 – Thermal profile of temperature humidity cycle test
+
+#### 10.2.1.6 Temperature humidity ageing
+
+The test procedure should be in accordance with [IEC 61300], part 2-19, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Temperature: $+75^{\circ}\text{C}$ (or $+85^{\circ}\text{C}$ as an alternate condition).
+- Relative humidity: 85%.
+- Duration of exposure: 336 hours.
+
+#### 10.2.1.7 Water immersion
+
+The test procedure should be in accordance with [IEC 61300], part 2-45, and the insertion loss measurements are performed before, during and after this test. The test parameter values are as follows:
+
+- Temperature: $43 \pm 2^{\circ}\text{C}$ .
+- pH: $5.5 \pm 0.5$ .
+- Duration of exposure: 168 hours.
+
+#### **10.2.1.8 Flammability (for indoor applications)**
+
+The test procedure should be in accordance with [IEC 60695-11-10] test method B.
+
+Exposed materials of the splitter housing shall not sustain combustion when an open flame source is removed.
+
+#### **10.2.1.9 Toxicity**
+
+All optical branching component materials shall be non-toxic.
+
+#### **10.2.1.10 Fungus resistance**
+
+Optical branching component materials shall not support fungus growth.
+
+#### **10.2.1.11 Salt spray**
+
+The test procedure should be in accordance with [IEC 61300], part 2-26, and the insertion loss measurements are performed before, during and after this test. The test parameter values are as follows:
+
+- Temperature: 35° C.
+- Solution concentration: 5% by weight (NaCl).
+- Duration of exposure: 168 hours.
+- No visual evidence of corrosion after the test.
+
+### **10.2.2 Additional reliability requirements**
+
+The requirements in this clause are intended to assess reliability on a longer term basis. Applicability is to be agreed between user and supplier.
+
+#### **10.2.2.1 Vibration**
+
+The test procedure should be in accordance with [IEC 61300], part 2-1, and insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Frequency range: 20-2000 Hz.
+- Maximum acceleration: 20 g.
+- Endurance duration: 4 minutes per cycle and 4 cycles in each of the orientations, X, Y and Z.
+
+#### **10.2.2.2 Impact**
+
+The test procedure should be in accordance with [IEC 61300], part 2-9, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Peak acceleration and duration: 1000 g; 0.5 ms pulse duration.
+- Number of impacts: 8 per direction.
+- Number of axes: 3 (2 directions per axis).
+
+#### **10.2.2.3 Cyclic moisture resistance**
+
+The test procedure should be in accordance with [IEC 61300], part 2-21, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows (see Figure 10-2):
+
+- Temperature range: –40 to +75° C.
+- Relative humidity: 85-95% RH at +75° C; uncontrolled at 25° C and –40° C.
+- Duration at extreme temperature: 3 to 16 hours.
+- Number of cycles: 5 (each cycle has 5 sub-cycles) (35 h/cycle).
+
+
+
+Figure 10-2: Thermal profile of cyclic moisture resistance test. The graph shows Temperature (degrees Celsius) on the y-axis (from -50 to +100) versus Time (hours) on the x-axis. The profile consists of 15 cycles of temperature cycling. Each cycle includes a high temperature plateau at +75°C (labeled '85-95% RH' with an arrow), a low temperature plateau at -40°C, and a transition between them. The high temperature plateau duration is approximately 4.5 hours, and the low temperature plateau duration is approximately 1.5 hours. The transition time between plateaus is maximum 10 seconds. The overall cycle duration is 6 hours. The graph is labeled L.37(07)\_F03.
+
+**Figure 10-2 – Thermal profile of cyclic moisture resistance test**
+
+#### 10.2.2.4 Thermal shock
+
+The test procedure should be in accordance with [IEC 61300], part 2-47, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- Temperature range: 0 to 100° C.
+- Duration at extreme temperature: minimum 5 min.
+- Change-over time: maximum 10 s.
+- Number of cycles: 15.
+
+#### 10.2.2.5 Temperature cycling
+
+The test procedure should be in accordance with [IEC 61300], part 2-22, and the insertion loss measurements are performed before and after this test. The test parameter values are as follows:
+
+- High temperature: +85° C.
+- Low temperature: –40° C.
+- Temperature rate of change: 1° C/min.
+- Number of cycles: 500 (4.5 h/cycle).
+
+#### 10.2.2.6 Low temperature storage
+
+The test procedure should be in accordance with [IEC 61300], part 2-17, and the insertion loss measurements are performed before, during and after this test. The test parameter values are as follows:
+
+- Temperature: –40° C.
+- Duration of exposure: 2000 hours (and up to 5000 hours for information).
+
+#### 10.2.2.7 High temperature storage
+
+The test procedure should be in accordance with [IEC 61300], part 2-19, and the insertion loss measurements are performed before, during and after this test. The test parameter values are as follows:
+
+- Temperature: +85° C.
+- Relative humidity: +85% RH.
+- Duration of exposure: 2000 hours (and up to 5000 hours for information).
+
+#### 10.2.2.8 Maximum input power
+
+The incident light shall not cause any optical branching component to deteriorate.
+
+The test procedure should be in accordance with [IEC 61300], part 2-14.
+
+The maximum input power conditions should be decided by agreement between user and supplier.
+
+#### **10.2.2.9 Failure rate**
+
+FIT rates can be determined by applying [IEC 62005-2]. The required application and operational conditions (such as temperature and humidity), as well as the required FIT rate, are to be agreed between user and supplier.
+
+# Appendix I
+
+## Optional performance requirement
+
+(This appendix does not form an integral part of this Recommendation)
+
+These requirements can be added to the basic test plan in agreement between user and supplier. They have been applied in applications in some regions in the world.
+
+## **I.1 Low temperature storage**
+
+The test procedure should be in accordance with [IEC 61300], part 2-17, and the insertion loss measurements at 1310 and 1550 nm are performed before, during and after this test. The test parameter values are as follows:
+
+- Temperature: $-40^{\circ}\text{C}$ .
+- Duration of exposure: 336 hours.
+
+## Appendix II
+
+## Additional criteria for performance and reliability tests for optical branching components for PONs
+
+(This appendix does not form an integral part of this Recommendation)
+
+These are additional performance criteria, historically used by some operators:
+
+### II.1 Introduction
+
+This appendix describes the criteria for performance and reliability tests for optical branching components for PONs.
+
+## II.2 Criteria for performance and reliability tests for optical branching components for PONs
+
+The following shows the criteria for performance and reliability tests for optical branching components for PONs.
+
+#### II.2.1 Mechanical integrity
+
+The criteria for the mechanical integrity requirements of optical branching components for PONs are shown in Table II.1. The criteria values are the differences between the insertion loss values (wavelengths: 1310 and 1550 nm) before and after each test procedure. The number of output ports of optical branching components for PONs is 4, 8, 16 or 32.
+
+Table II.1 – Mechanical integrity criteria
+
+| Test | Criteria (at 1310 and 1550 nm) | |
+|------------------------|-------------------------------------|-------------------------------------|
+| | Output port: 4, 8 | Output port: 16, 32 |
+| Vibration (basic) | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Vibration (additional) | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Impact (additional) | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Impact (basic) | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Fibre retention | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Fibre side pull | +0.2/-0.2 dB, before and after test | +0.5/-0.5 dB, before and after test |
+
+#### II.2.2 Short-term reliability
+
+The criteria of the short-term reliability requirements for optical branching components for PONs are shown in Table II.2. The criteria values are the differences between the insertion loss values (wavelengths: 1310 and 1550 nm) before and after each test procedure. The number of output ports of optical branching components for PONs is 4, 8, 16 or 32.
+
+**Table II.2 – Short-term reliability criteria**
+
+| Test | Criteria (at 1310 and 1550 nm) | |
+|-----------------------------|---------------------------------------------|---------------------------------------------|
+| | Output port: 4, 8 | Output port: 16, 32 |
+| Temperature humidity cycle | +0.3/-0.3 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+| Low temperature storage | +0.2/-0.2 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+| Temperature humidity ageing | +0.3/-0.3 dB, before and after test | +0.5/-0.5 dB, before and after test |
+| Cyclic moisture resistance | +0.3/-0.3 dB, before and after test | +0.5/-0.5 dB before and after test |
+| Thermal shock | +0.3/-0.3 dB, before and after test | +0.5/-0.5 dB before and after test |
+
+#### II.2.3 Long-term reliability
+
+The criteria of the long-term reliability requirements for optical branching components for PONs are shown in Table II.3. The criteria values are the differences between the insertion loss values (wavelengths: 1310 and 1550 nm) before and after each test procedure. The number of output ports of optical branching components for PONs is 4, 8, 16 or 32.
+
+**Table II.3 – Long-term reliability criteria**
+
+| Test | Criteria (at 1310 and 1550 nm) | |
+|--------------------------|---------------------------------------------|---------------------------------------------|
+| | Output port: 4, 8 | Output port: 16, 32 |
+| Temperature cycling | +0.3/-0.3 dB, before and after test | +0.5/-0.5 dB before and after test |
+| Low temperature storage | +0.3/-0.3 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+| High temperature storage | +0.3/-0.3 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+
+#### II.2.4 Weather resistance
+
+The weather resistance criteria for optical branching components for PONs are shown in Table II.4. The criteria values are the differences between the insertion loss values (wavelengths: 1310 and 1550 nm) before and after each test procedure. The number of output ports of optical branching components for PONs is 4, 8, 16 or 32.
+
+**Table II.4 – Weather resistance criteria**
+
+| Test | Criteria (at 1310 and 1550 nm) | |
+|-------------------|---------------------------------------------|---------------------------------------------|
+| | Output port: 4, 8 | Output port: 16, 32 |
+| Salt spray | +0.2/-0.2 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+| Water immersion | +0.2/-0.2 dB, before, during and after test | +0.5/-0.5 dB, before, during and after test |
+| Toxicity | Non-toxic | Non-toxic |
+| Fungus resistance | Does not support fungus growth | Does not support fungus growth |
+| Flammability | V-0 | V-0 |
+
+#### II.2.5 Optical power characterization
+
+The optical power characterization criterion for optical branching components for PONs is shown in Table II.5.
+
+**Table II.5 – Optical power characterization criterion**
+
+| Test | Criterion |
+|---------------------|---------------------------------|
+| | 1550 nm |
+| Maximum input power | 20 dBm, guaranteed for 20 years |
+
+#### II.2.6 Failure rate
+
+The information specifications that are required to describe the failure rate of optical branching components for PONs should be provided by the suppliers.
+
+The FIT rate for a range of application temperature and humidity over the lifetime of the component shall be calculated from the results of suitable accelerated life tests. For example, [IEC 62005-2] provides a methodology for carrying out these calculations.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.40-200010-I_PDF-E/raw.md b/marked/L/T-REC-L.40-200010-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..d9f7b06133a2c36cbc125333730dd8ff793b2f84
--- /dev/null
+++ b/marked/L/T-REC-L.40-200010-I_PDF-E/raw.md
@@ -0,0 +1,1220 @@
+
+
+
+
+The logo of the International Telecommunication Union (ITU) features a globe with a lightning bolt striking across it, and the letters 'ITU' superimposed on the globe.
+
+ITU logo
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.40**
+
+(10/2000)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Optical fibre outside plant maintenance support,
+monitoring and testing system**
+
+ITU-T Recommendation L.40
+
+(Formerly CCITT Recommendation)
+
+---
+
+# **Optical fibre outside plant maintenance support, monitoring and testing system**
+
+## **Summary**
+
+Outdoor optical fibre maintenance is important to create networks and to maintain their reliability. As traffic increases, higher capacity fibre cables are installed. Recently, optical fibre cables with over 100 cores have become common, so many transmission systems use the same optical fibre cable. Minimal levels of maintenance and testing are required to provide high reliability and quick response.
+
+After a cable is installed, functions like fibre monitoring and control have to be done without interfering with the data transmission signals. By monitoring dark fibres (that is, without signal traffic) an indication is given of the performance of the in-service fibres as the degradation and breaks that a cable undergoes affects all fibres in the same way. Nevertheless greater reliability is achieved by monitoring the fibres with traffic. Also fibre identification is important to control fibre networks because several fibres may have to be chosen from within a cable, even if the cable has many fibres in-service.
+
+## **Source**
+
+ITU-T Recommendation L.40 was prepared by ITU-T Study Group 6 (1997-2000) and approved by the World Telecommunication Standardization Assembly (Montreal, 27 September – 6 October 2000).
+
+This Recommendation includes Appendices I to V approved on 9 March 2001.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database.
+
+© ITU 2001
+
+All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from ITU.
+
+## CONTENTS
+
+| | | Page |
+|--------|-------------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | Fundamental requirements..... | 1 |
+| 2.1 | Functions..... | 1 |
+| 2.2 | Interface ..... | 1 |
+| 3 | Testing and maintaining principle ..... | 2 |
+| 3.1 | Methods ..... | 2 |
+| 3.2 | Wavelength ..... | 2 |
+| 4 | Fundamental architecture..... | 3 |
+| 4.1 | General system architecture..... | 3 |
+| 4.2 | Optical testing module (OTM) ..... | 5 |
+| | Appendix I – United States experience regarding remote fibre monitoring and testing ..... | 6 |
+| I.1 | Introduction..... | 6 |
+| I.2 | Remote fibre testing and monitoring architectures..... | 6 |
+| I.2.1 | Basic dark fibre remote test systems (RFTSs)..... | 6 |
+| I.2.2 | Remote fibre test systems with active fibre monitoring and testing..... | 7 |
+| I.2.3 | RFTS manager..... | 8 |
+| I.2.4 | Alarms ..... | 8 |
+| I.3 | Conclusions..... | 9 |
+| I.4 | References..... | 10 |
+| | Appendix II – Optical fibre outside plant maintenance support and testing system ..... | 10 |
+| II.1 | Abstract..... | 10 |
+| II.1.1 | Fundamental requirements ..... | 10 |
+| II.1.2 | Testing and maintaining principle ..... | 11 |
+| II.1.3 | Fundamental architecture ..... | 12 |
+| II.2 | Detail of the system ..... | 13 |
+| II.2.1 | Purposes..... | 13 |
+| II.2.2 | System functions..... | 13 |
+| II.2.3 | System configuration..... | 14 |
+| II.2.4 | Control system overview ..... | 15 |
+| II.2.5 | Testing and measurement principles ..... | 16 |
+| II.3 | Mandatory conditions ..... | 18 |
+| II.3.1 | Network topologies..... | 18 |
+| II.3.2 | Capacities..... | 18 |
+| II.3.3 | Test wavelength..... | 18 |
+
+| | Page |
+|---------------------------------------------------------------------------------------------------------------|-------------|
+| II.3.4 System data management ..... | 18 |
+| II.3.5 Interface ..... | 19 |
+| Appendix III – Optical fibre outside plant maintenance support and testing system ..... | 19 |
+| III.1 Introduction..... | 19 |
+| III.2 Scenario ..... | 20 |
+| III.3 Benefits of attenuation continuous monitoring..... | 20 |
+| III.4 Basic principles of the optical cable supervisory system ..... | 22 |
+| III.5 Requirements of the optical cable supervisory system..... | 22 |
+| III.6 Conclusions..... | 26 |
+| Appendix IV – The Indonesian experience on optical fibre cable operation and maintenance support system ..... | 26 |
+| IV.1 Introduction..... | 26 |
+| IV.2 Fundamental requirements..... | 27 |
+| IV.3 System's basic configuration..... | 27 |
+| IV.4 Functions of main units..... | 28 |
+| IV.5 System's hardware configuration..... | 29 |
+| IV.6 General specification of optical fibre cable O&M support system ..... | 30 |
+| IV.6.1 Test scope ..... | 30 |
+| IV.6.2 Capacities..... | 31 |
+| IV.6.3 Test wavelength..... | 31 |
+| IV.6.4 Test distance restrictions ..... | 31 |
+| IV.6.5 System data management ..... | 31 |
+| IV.6.6 Coupling loss and reflection measurement..... | 31 |
+| IV.6.7 Transmission conditions ..... | 32 |
+| IV.6.8 System use conditions ..... | 32 |
+| IV.7 Application software..... | 32 |
+| Appendix V – Spain's experience of an optical fibre monitoring system (OFMS) ..... | 33 |
+| V.1 Introduction..... | 33 |
+| V.2 General..... | 34 |
+| V.3 Optical fibre monitoring system (OFMS) – General description ..... | 34 |
+| V.4 System performance ..... | 34 |
+| V.5 System..... | 35 |
+| V.6 Incorporation of the system in the centralized monitoring structure ..... | 36 |
+
+# ITU-T Recommendation L.40
+
+# Optical fibre outside plant maintenance support, monitoring and testing system
+
+# 1 Scope
+
+This Recommendation deals with outdoor optical fibre maintenance support, monitoring and testing systems for both trunk and access optical fibre cable networks. It describes fundamental requirements, principles, and architecture to develop a suitable guide to design systems.
+
+# 2 Fundamental requirements
+
+## 2.1 Functions
+
+The system has functions shown in Table 1.
+
+**Table 1/L.40 – Functions and status**
+
+| Category | Activity | Functions | Status |
+|----------------------------------------------------------------------|------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------|
+| Preventative maintenance | Surveillance (e.g. Periodic testing, Continuous testing) | • Detection of fibre loss increase • Detection of signal power loss increase • Detection of water penetration | Optional Optional Optional |
+| | Testing (e.g. Fibre degradation testing) | • Measurement of fibre fault location • Measurement of fibre strain distribution • Measurement of water location | Optional Optional Optional |
+| | Control (e.g. Network element control) | • Fibre identification • Fibre transfer | Optional Optional |
+| After installation before service or post-fault maintenance | Surveillance (e.g. Reception of transmission system alarm or customer trouble report) | • Interface with path operation system • Interface with customer service operation system | Optional Optional |
+| | Testing (e.g. After installation testing, Fibre fault testing) | • Confirmation of fibre condition • Fault distinction between transmission equipment and fibre network • Measurement of fibre fault location | Required Required Required |
+| | Control (e.g. Cable install/repair/ replacement) | • Fibre identification • Fibre transfer • Interface with outside plant database • Interface with mapping system | Required Optional Required Optional |
+
+## 2.2 Interface
+
+The system can be controlled by human or by other systems. The system shall be able to be remotely controlled. So operation terminals with HMI (human-machine interface) should be included in the system.
+
+The system shall be able to gather data about outdoor fibres from the outside plant database and it should have interface with path operation and customer service system.
+
+The interface may be implemented in a variety of ways, for example:
+
+- 1) standard on-line interface;
+- 2) proprietary on-line interface;
+- 3) an external storage medium such as magnetic optical disc or floppy disc.
+
+# 3 Testing and maintaining principle
+
+## 3.1 Methods
+
+There are several ways to implement these functions. OTDR testing, loss testing, monitoring a proportion of the signal power (power monitoring) and identification light detection are commonly used. Table 2 shows the most common methods.
+
+**Table 2/L.40 – Suitable test methods**
+
+| Category | Activity | Functions | Methods |
+|-------------------------------------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------|
+| Preventative maintenance | Surveillance | • Detection of fibre loss increase • Detection of signal power loss increase • Detection of water penetration | OTDR/loss testing Power monitoring OTDR/loss testing |
+| | Testing | • Measurement of fibre fault location • Measurement of fibre strain distribution • Measurement of water location | OTDR testing B-OTDR testing OTDR testing |
+| | Control | • Fibre identification • Fibre transfer | ID light detecting a) Switching b) |
+| After installation before service or post-fault maintenance | Surveillance | • Interface with path operation system • Interface with customer service operation system | On-line/external medium On-line/external medium |
+| | Testing | • Confirmation of fibre condition • Fault distinction between transmission equipment and fibre network • Measurement of fibre fault location | OTDR/loss testing OTDR/loss testing OTDR testing |
+| | Control | • Fibre identification • Fibre transfer • Interface with outside plant database • Interface with mapping system | ID light detecting Switching b) On-line/external medium On-line/external medium |
+
+a) ID light means identification light such as 270 Hz, 1 kHz, 2 kHz modulated light.
+b) Switching includes mechanical and manual switching.
+
+## 3.2 Wavelength
+
+It is important to choose the correct wavelength. Specifically, maintenance functions have to be performed without interfering with data transmission signals. Table 3 shows appropriate wavelengths for given functions.
+
+**Table 3/L.40 – Wavelength selection**
+
+| Category | Activity | Functions | Wavelength |
+|-------------------------------------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------|
+| Preventative maintenance | Surveillance | • Detection of fibre loss increase • Detection of signal power loss increase • Detection of water penetration | Maintenance wavelength a) Signal wavelength Any wavelength on fibres not carrying signals |
+| | Testing | • Measurement of fibre fault location • Measurement of fibre strain distribution • Measurement of water location | Any wavelength on fibres not carrying signals Any wavelength on fibres not carrying signals Any wavelength on fibres not carrying signals |
+| | Control | • Fibre identification • Fibre transfer | Maintenance wavelength a) None |
+| After installation before service or post-fault maintenance | Surveillance | • Interface with path operation system • Interface with customer service operation system | None None |
+| | Testing | • Confirmation of fibre condition • Fault distinction between transmission equipment and fibre network • Measurement of fibre fault location | Any wavelength Any wavelength Any wavelength |
+| | Control | • Fibre identification • Fibre transfer • Interface with outside plant database • Interface with mapping system | Any wavelength None None None |
+
+a) Refer to "Recommendation of Maintenance wavelength on fibres carrying signals (ITU-T L.41)".
+
+# 4 Fundamental architecture
+
+## 4.1 General system architecture
+
+Systems (see Figure 1) must have at least an operation terminal and optical testing module (OTM). The minimum system consists of only these two items. This type of system is convenient for initial installation. A server can improve performance by keeping outside plant, test results, and interfaces with other systems. The server can also control OTMs.
+
+There are several choices for Data Communication Network (DCN), including POTS, ISDN and X.25. Traffic analysis is important for an economical high-performance system.
+
+
+
+```
+
+graph TD
+ subgraph "Stand-alone Type"
+ DCN1[DCN] -- OTM1[OTM]
+ DCN1 -- OT1[Operation Terminal]
+ OT1 -- DB1[(DB)]
+ end
+ subgraph "Client-Server Type"
+ S2[Server] -- DB2[(DB)]
+ S2 -- DCN2[DCN]
+ DCN2 -- OTM2[OTM]
+ DCN2 -- OT2[Operation Terminal]
+ end
+
+```
+
+Figure 1/L.40 – System architectures. Diagram showing Stand-alone Type and Client-Server Type architectures.
+
+DB Database
+
+T0604740-00
+
+**Figure 1/L.40 – System architectures**
+
+Figure 2 shows these system interfaces. There are several kinds of interface between an operating system (OS), which runs on an operation terminal or server, and OTM. A proprietary interface is convenient for closed systems. Standard interfaces are useful for open systems. A hybrid type is also possible.
+
+The system has to have interfaces with other systems. This may be done in a variety of ways, for example:
+
+- 1) standard on-line interface;
+- 2) proprietary on-line interface;
+- 3) an external storage medium such as magnetic optical disc or floppy disc.
+
+
+
+The diagram illustrates three system interface configurations for an Optical Testing Module (OTM):
+
+- Proprietary Type:** An OS is connected to a DCN via a Proprietary IF. The DCN is connected to an OTM via a Proprietary IF. An Other OS is also connected to the DCN via a Proprietary IF.
+- Standard Type:** An OS is connected to a DCN via a Standard IF. The DCN is connected to an OTM via a Standard IF. An Other OS is also connected to the DCN via a Standard IF.
+- Hybrid Type:** An OS is connected to a DCN via a Standard IF. The DCN is connected to an MD via a Standard IF. The MD is connected to an OTM via a Proprietary IF. An Other OS is connected to the MD via a Proprietary IF.
+
+T0604750-00
+
+Diagram illustrating system interfaces for three types of Optical Testing Module (OTM) connections: Proprietary Type, Standard Type, and Hybrid Type. Each type shows the connection between an OS (Optical System), DCN (Data Communication Network), MD (Mediation Device), and OTM (Optical Testing Module) using Standard or Proprietary interfaces.
+
+MD Mediation Device
+
+**Figure 2/L.40 – System interfaces**
+
+## 4.2 Optical testing module (OTM)
+
+The optical testing module (OTM) consists of a controller, an optical testing unit (OTU), fibre selectors (FS), optical couplers, filters, water sensors and by path units.
+
+- 1) The controller controls the OTU, communicates with the server or the operation terminal, and analyses test results, along with performing several other functions.
+- 2) The OTU is used for the actual testing. It comprises an Optical Time Domain Reflection meter (OTDR) and other instruments, light sources, power meters and a controller for these devices.
+- 3) Fibre selectors (FS) are installed within a fibre termination frame and/or an OTU frame. Their function is to select the fibre to be tested under instruction from the OTU.
+- 4) An optical coupler is installed within a fibre termination frame. Its function is to inject and detect a test light in the optical fibre or to detect a proportion of the signal for monitoring proposes.
+- 5) A filter is installed to protect transmission equipment from being affected by the test light.
+- 6) A water sensor is installed at the optical fibre cable joints to detect the water penetration.
+- 7) A bypass unit is used to make a roundabout route to avoid a transmission device.
+
+# United States experience regarding remote fibre monitoring and testing
+
+## I.1 Introduction
+
+Based on our experience with customers in the United States, many of the larger network providers that predominantly provide local telephony services do not use Remote Fibre Test Systems (RFTSs). These companies rely on transmission system equipment alarms, ring topology and protection switching. In response to an alarm, traffic is switched to an alternate fibre, and after applying proprietary maintenance analyses an OTDR is used to determine the location of a cable break. These companies have historical and landmark data available for fault location. Network providers that are predominantly long-distance providers do use some level of remote fibre testing systems in their networks.
+
+The RFTSs range from the basic dark fibre systems to identify and roughly locate fibre breaks to more sophisticated systems that can monitor working systems, detect degradation of the network before it fails and accurately locates fibre faults. RFTSs may be controlled locally, regionally or at a central maintenance centre of a network provider. In the case of the dark fibre system, the main purpose is to reduce the time to locate faults and thus reduce the time of circuit outages. The sophisticated systems are integrated into the network surveillance operational system that monitors the transmission, switching equipment and the RFTS. These systems can also determine degradation of the fibre network and sound alarms before the network is out of service.
+
+## I.2 Remote fibre testing and monitoring architectures
+
+### I.2.1 Basic dark fibre remote test systems (RFTSs)
+
+The basic dark fibre Remote Fibre Test System (RFTS), shown in Figure I.1, consists of three elements. The first is an Optical Test Access Unit (OTAU), which is essentially a remotely controlled optical switch. The size of the switch depends on the number of fibres under test, a common size is 72 fibres, but larger switches are used. The switch connects the test fibres to the second element, the Remote Test Unit (RTU), which is a remotely controlled OTDR that provides the test signal and makes the OTDR measurements. The third element is the Test System Controller (TSC), which selects the test fibre and operates the RTU. This architecture is typical of the dark fibre monitoring in use today in the United States. The test operating system may be integrated into a surveillance operational system using proprietary software.
+
+In a stand-alone system the TSC contains a database for the fibres under test that includes prior OTDR trace data and related geographic data of the fibre routes. In these systems only dark fibres are tested. The RFTS is capable of fault detection based on a process where the TSC cycles through each fibre connected to it. One TSC can control multiple RTUs. This means that a TSC may not discover a cable break for some time if the number of fibres connected to it is very large and if the fibres of that cable were tested shortly before the break occurred. The TSC may be connected to a Test Operating System (Test OS), which is located in a maintenance centre where other alarms from the network terminate. Operators there analyse the alarms coming from the TSC and other sources, such as transmission alarms, determine the root cause of the problem and obtain OTDR trace information from the TSC before dispatching a repair crew. If a transmission alarm is received first, the TOS can interrupt the test cycling, and direct the TSC to make a scan of the fibre with a transmission fault.
+
+
+
+This block diagram illustrates a basic dark fibre remote fibre test system (RFTS). On the left, a box labeled 'Test Operating System (Test OS)' is connected via a double-headed arrow to a 'Test System Controller (TSC)' box. The 'TSC' is connected via a double-headed arrow to a 'Remote Test Unit (RTU)' box. The 'RTU' is connected via a single-headed arrow to an 'Optical Test Access Unit (OTAU)' box. The 'OTAU' has three output lines, each ending in a yellow circle with an upward-pointing arrow, representing optical fibres. A label 'T0605150-01' is located at the bottom right of the diagram.
+
+Figure I.1/L.40 – Basic dark fibre remote fibre test system (RFTS)
+
+**Figure I.1/L.40 – Basic dark fibre remote fibre test system (RFTS)**
+
+Many of the current systems in use today are vendor specific and not compatible with other vendor products on a system or component basis. Requirements for RFTSs that will overcome this problem in new systems put into use in the United States have been developed [1], [2] and [3].
+
+Monitoring only the dark fibres cannot assure detection of faults that may occur with the working fibres. For example if water entered the cable and freezing occurred, some of the working fibres could experience high loss while the monitored dark fibres are unaffected. This problem can be overcome with monitoring of more fibres, including the active fibres. Of course, the number of fibres monitored increases the cost, which places a practical limit on how many fibres are monitored. Typically, only one or two fibres are monitored per cable.
+
+### I.2.2 Remote fibre test systems with active fibre monitoring and testing
+
+The transmitted and/or received signal can be monitored full time and an OTDR test signal, which is out of the transmission band, can be injected into the OSP fibre without interference with the transmission by placing a WDM device between the transmission equipment and the OSP fibre. Figure I.2 illustrates this architecture and is representative of systems in use today [4]. The sophistication of the system depends upon the RFTS manager function that is discussed in I.2.3.
+
+
+
+This block diagram illustrates power monitoring and wavelength division multiplexing (WDM) for an OTDR test signal with service transmission. On the left, an 'Optical Test Access Unit (OTAU)' box is connected via a yellow circle with an upward-pointing arrow (labeled 'Test λ') to a 'Power Monitoring and Wavelength Multiplexing' box. Below the OTAU, a 'Transmission Equipment' box is connected via a yellow circle with an upward-pointing arrow (labeled 'Service λ') to the same 'Power Monitoring and Wavelength Multiplexing' box. The output of the multiplexing box is labeled 'To OSP' and is connected via a yellow circle with an upward-pointing arrow (labeled 'Test λ and Service λ'). A label 'T0605160-01' is located at the bottom right of the diagram.
+
+Figure I.2/L.40 – Power monitoring and wavelength division multiplexing an OTDR test signal with service transmission
+
+**Figure I.2/L.40 – Power monitoring and wavelength division multiplexing an OTDR test signal with service transmission**
+
+With this architecture there are a number of benefits:
+
+- 1) The RTU need only be used to locate faults that are detected by loss of signal power.
+- 2) The detection of signal loss would be essentially instantaneous; with the detection of loss of power, the monitoring circuitry can signal the TSC to direct the RTU and the OATU to make a test and locate the fault.
+- 3) Both active and dark fibres can be batch tested.
+- 4) Power monitoring as well as routine OTDR test data can be used to do proactive maintenance. It can support the detection of transmission quality degradation and observe the quality of the fibre over long periods of time for failure prediction.
+
+### I.2.3 RFTS manager
+
+The RFTS manager, generally a PC with special fibre application software (FAS), communicates with the surveillance operations system (SOS), but it can also be accessed locally and directly from the field. The RFTS manager controls the RFTS equipment and stores data on the fibres monitored in its system, such as landmarks and other geographical information, OTDR traces, statistical data, alarm policy, and monitoring and test data. When an alarm is received, the manager directs the RFTS equipment (TSC, RTU and OTA) to make a test. It processes the test data, and forwards to the SOS the location of the fault relative to landmark data for the repair crews. During a cable break, the SOS receives alarm information from the transmission equipment, from the protection switching equipment (if protection switching is used) and from the RFTS manager. With suitable correlation algorithms at both the RFTS manager and the SOS the several alarms can be sorted and only one alarm prevails. In the case of a cable break, it is the RFTS alarm with the necessary fault location information to dispatch a repair crew. Figure I.3 below illustrates this process.
+
+
+
+T0605170-01
+
+Diagram illustrating the telecommunications maintenance hierarchy with a focus on alarm correlation. The diagram shows three layers: Network Mgmt Layer, Element Mgmt Layer, and Network Element Layer. At the top, a 'SITUATION: CABLE CUT' is shown. The Network Mgmt Layer contains a 'Surveillance OS' box with 'Cross Functional Alarm Correlation Rules' and 'Root Cause Determination Algorithms'. The Element Mgmt Layer contains 'Transmission Equip Mgr', 'Switching Equip Mgr', and 'RFTS Mgr w/ Correlation Engine'. The Network Element Layer contains 'Transmission Equipment', 'Switching Equipment', and 'RFTS Equipment'. Arrows show alarm flow: from Network Element Layer to Element Mgmt Layer (labeled 'Service Alarm Resultering From Cable Cut'), from Element Mgmt Layer to Network Mgmt Layer (labeled 'Reduced Set of Alarms Based on Manager's Correlation'), and from RFTS Equipment to RFTS Mgr (labeled 'One Alarm For Each Monitored Fibre in Cable'). The RFTS Mgr then sends an alarm to the Surveillance OS (labeled 'Correlation Engine Yields One Alarm - Cable Cut').
+
+**Figure I.3/L.40 – Telecommunications maintenance hierarchy with focus on alarm correlation**
+
+### I.2.4 Alarms
+
+For the most sophisticated systems, the FAS software provides an extensive set of alarm capabilities to alert maintenance personnel to fibre related issues. Fibres alarms are pre-set to detect changes in fibre path performance associated with comparative batch testing or power monitoring. The system also provides alarm information associated with equipment and other environmental fault conditions. All alarm information may be accessed via alarm lists maintained by the RFTS manager. A remote
+
+paging capability may also be preprogrammed to "beep" craft in the event of a fibre or equipment issue.
+
+#### I.2.4.1 Alarm levels
+
+Typically, there are two levels of alarm criticality:
+
+**Major Alarm** – A major alarm is generated when there is a transmission failure. It can be generated when power monitoring detects a power drop below a set threshold or through batch testing. Batch testing generates a major alarm when there is an event loss greater than 3 dB (or another threshold set by the user). The problem is assumed to be a fibre break or of similar criticality. Major alarms require action by the maintenance personnel and most likely a field operation such as a cable repair.
+
+**Minor Alarm** – A minor alarm can be signalled when a batch OTDR test has detected that the fibre trace has violated a threshold for attenuation, attenuation coefficient, reflectance, or a new event has been discovered. A minor event is also signalled when power monitoring detects a signal above or below the dynamic range or when the laser power is not stable. Minor alarms should be watched to determine if the condition is getting progressively worse, but do not require immediate site investigation.
+
+#### I.2.4.2 OTDR alarms
+
+Alarms are triggered during an OTDR test when the alarm threshold level is crossed. There are default threshold crossing alarms for: end-to-end loss, an event loss, an event reflection, a new event, an event changes from non-reflection to reflection, and change in the attenuation coefficient of the fibre. Typical default alarm threshold values determined from experience are shown in Table I.1.
+
+**Table I.1/L.40 – Typical default alarm threshold values**
+
+| | |
+|------------------------------|---------------|
+| End-to-end loss | 3.0 dB change |
+| Event loss | 0.5 dB change |
+| Event reflection | 5 dB |
+| New event | 1.0 dB |
+| Attenuation coefficient | 0.5 dB/km |
+| Non-reflection to reflection | >1.0 dB |
+
+#### I.2.4.3 Power alarms
+
+Power alarms are triggered whenever the power level or the variation in power level crosses an alarm threshold. The typical minor default threshold for power level is 1.0 dB, and a major default threshold for power level is 3.0 dB.
+
+## I.3 Conclusions
+
+Network providers in the United States either use no RFTSs or they use RFTSs to monitor dark fibres or both dark and active fibres. Those providers who do not use any RFTSs rely on transmission equipment alarms, protective switching, ring topology, and OTDR traces with landmarks to locate the fault. Alternate routing through protective switching and ring topology allows time for normal location and restoration. Those who use power monitoring and out-of-band OTDR scans consider the faster restoration, the statistical and predictive information are worth the added operational costs for the RFTSs.
+
+## I.4 References
+
+- [1] *Generic Requirements for Remote Fibre Testing Systems (RFTSs)*, Telecordia, BR-GR 1295-Core Issue 02 2000-02-07.
+- [2] *OTGR Section 6.6 TSC/RTS and OTAU Generic Requirements for Remote Optical Fibre Testing*, Telecordia, BR-GR 1309-Issue 01 1995/06.
+- [3] *Generic Requirements for Fibre Optic Branching Components*, Telecordia, BR-GR 1209-CORE issue 02 1998/02/01.
+- [4] *A Next Generation Fibre Test and Surveillance System*, Lucent Technologies, ITU, COM 6-60-E, Study Period 1997-2000.
+
+# APPENDIX II
+
+# Optical fibre outside plant maintenance support and testing system
+
+## II.1 Abstract
+
+This Recommendation describes fundamental requirements, principles, and architecture to develop a suitable guide to design systems. This appendix presents a Japanese system derived from this Recommendation.
+
+### II.1.1 Fundamental requirements
+
+#### II.1.1.1 Functions
+
+The Japanese system has functions shown in Table II.1.
+
+**Table II.1/L.40 – Functions and status**
+
+| Category | Activity | Functions | Status |
+|-------------------------------------------------------------|------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------|
+| Preventative maintenance | Surveillance (e.g. Periodic testing, Continuous testing) | • Detection of fibre loss increase • Detection of signal power loss increase • Detection of water penetration | X X X |
+| | Testing (e.g. Fibre degradation testing) | • Measurement of fibre fault location • Measurement of fibre strain distribution • Measurement of water location | X Optional X |
+| | Control (e.g. Network element control) | • Fibre identification • Fibre transfer | X Optional |
+| After installation before service or post-fault maintenance | Surveillance (e.g. Reception of transmission system alarm or customer trouble report) | • Interface with path operation system • Interface with customer service operation system | Optional Optional |
+| | Testing (e.g. After installation testing, Fibre fault testing) | • Confirmation of fibre condition • Fault distinction between transmission equipment and fibre network • Measurement of fibre fault location | X X X |
+| | Control (e.g. Cable install/repair/replacement) | • Fibre identification • Fibre transfer • Interface with outside plant database • Interface with mapping system | X Optional X None |
+
+#### II.1.1.2 Interface
+
+The Japanese system can be remotely controlled by human or by other systems, and operation terminals with HMI (human-machine interface) are included in the system.
+
+The Japanese system shall be able to gather data about outdoor fibres from the outside plant database and it should have interface with customer service system.
+
+The interface is implemented in a proprietary online interface. An external storage medium such as magnetic optical disc or floppy disc shall be also possible.
+
+### II.1.2 Testing and maintaining principle
+
+#### II.1.2.1 Method
+
+See Table II.2.
+
+**Table II.2/L.40 – Suitable test methods**
+
+| Category | Activity | Functions | Methods |
+|-------------------------------------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------|
+| Preventative maintenance | Surveillance | • Detection of fibre loss increase • Detection of signal power loss increase • Detection of water penetration | OTDR testing Power monitoring OTDR testing |
+| | Testing | • Measurement of fibre fault location • Measurement of fibre strain distribution • Measurement of water location | OTDR testing B-OTDR testing OTDR testing |
+| | Control | • Fibre identification • Fibre transfer | ID light detectinga) Mechanical switching |
+| After installation before service or post-fault maintenance | Surveillance | • Interface with path operation system • Interface with customer service operation system | Online/ external medium Online/ external medium |
+| | Testing | • Confirmation of fibre condition • Fault distinction between transmission equipment and fibre network • Measurement of fibre fault location | OTDR/loss testing OTDR/loss testing OTDR testing |
+| | Control | • Fibre identification • Fibre transfer • Interface with outside plant database • Interface with mapping system | ID light detecting Mechanical switching Online None |
+
+a) ID light means identification light such as 270 Hz modulated light.
+
+#### II.1.2.2 Wavelength
+
+See Table II.3.
+
+**Table II.3/L.40 – Wavelength selection**
+
+| Category | Activity | Functions | Wavelength |
+|-------------------------------------------------------------|--------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------|
+| Preventative maintenance | Surveillance | Detection of fibre loss increase Detection of signal power loss increase Detection of water penetration | 1310/1550/1650 1310/1550 1550/1650 |
+| | Testing | Measurement of fibre fault location Measurement of fibre strain distribution Measurement of water location | 1310/1550/1650 1550/1650 |
+| | Control | Fibre identification Fibre transfer | 1550/1650 None |
+| After installation before service or post-fault maintenance | Surveillance | Interface with path operation system Interface with customer service operation system | None None |
+| | Testing | Confirmation of fibre condition Fault distinction between transmission equipment and fibre network Measurement of fibre fault location | 1310/1550/1650 1310/1550/1650 1310/1550/1650 |
+| | Control | Fibre identification Fibre transfer Interface with outside plant database Interface with mapping system | 1310/1550/1650 None None None |
+
+NOTE – Refer to ITU-T L.41 "Maintenance wavelength on fibres carrying signals".
+
+### II.1.3 Fundamental architecture
+
+#### II.1.3.1 General system architecture
+
+The Japanese system architecture is shown in Figure II.1.
+
+
+
+The diagram illustrates two system architectures for network management:
+
+- Stand-alone Type:** A DCN (Data Communication Network) block is connected to a stack of three OTM (Optical Transport Module) blocks below it. To the right of the DCN, an Operation Terminal (represented by a triangle) is connected to a DB (Database) cylinder. The DCN is also connected to this Operation Terminal.
+- Client-Server Type:** A DCN block is connected to a stack of three OTM blocks below it. Above the DCN, a Server block is connected to it, and the Server is connected to a DB (Database) cylinder. To the right of the DCN, an Operation Terminal (represented by a triangle) is connected to it.
+
+DB Database
+
+T0605180-01
+
+Diagram showing two system architectures: Stand-alone Type and Client-Server Type. Both show a DCN connected to an OTM stack and an Operation Terminal. In the Stand-alone Type, the Operation Terminal is connected to a DB. In the Client-Server Type, the DCN is connected to a Server, which is connected to a DB, and the Operation Terminal is connected to the DCN.
+
+**Figure II.1/L.40 – System architectures**
+
+Figure II.2 shows the Japanese system interfaces. The system has proprietary online interfaces with other systems. An external storage medium such as magnetic optical disc or floppy disc shall also be possible.
+
+
+
+The diagram illustrates the system interfaces for the Japanese system. It shows a central DCN (Data Communication Network) block connected to an OS (Operating System) block above it and an OTM (Optical Testing Module) block below it. Both connections are labeled 'Proprietary IF' (Interface). To the right, an 'Other OS' block is also connected to the DCN block via a 'Proprietary IF'. The diagram uses double lines to represent the interfaces. Below the diagram, the text 'T0605190-01' and 'Proprietary Type' are present.
+
+Diagram of system interfaces showing OS, Other OS, DCN, and OTM connected via Proprietary IF.
+
+**Figure II.2/L.40 – System interfaces**
+
+#### II.1.3.2 Optical testing module (OTM)
+
+The optical testing module (OTM) of the Japanese system shall conform completely with this Recommendation.
+
+## II.2 Detail of the system
+
+### II.2.1 Purposes
+
+The purposes of the automatic remote fibre testing system are efficient construction, maintenance and operation of optical fibre cable. The system supports the various tasks involved in the construction of optical fibre cables and installation on the customer's premises before they are put in service, and in the periodic work of fault location and changing over of fibres within the optical fibre cable while they are in service.
+
+### II.2.2 System functions
+
+The system has the functions listed below.
+
+- 1) Remote OTDR testing, section loss testing and fibre identification during optical fibre cable construction or installation on customer premises.
+- 2) Support for remote fault location and repair.
+- 3) Periodic OTDR testing for fibre faults.
+- 4) Loss measurement (OTDR testing) before and after fibre changing over.
+
+### II.2.3 System configuration
+
+The system is configured as described below.
+
+- 1) A server and database is located in the administrative office for management of the system.
+- 2) An operations terminal is installed in the maintenance operations centre for remote control of testing operations.
+- 3) A Test Equipment Module (referred to as TEM in this appendix) is used for the actual testing. It comprises measurement instruments, including an Optical Time Domain Reflection meter (OTDR), a light source and a controller for them.
+- 4) A Fibre Termination Frame (referred to as FTM in this appendix) terminates the optical fibre cable in the central office.
+- 5) A Fibre Selector is installed within the FTM. Its function is to select the fibre to be tested under instruction from the TEM.
+- 6) A Test Access Module (referred to as TAM in this appendix) is installed within the FTM. It is an optical coupler whose function is to inject a test light into the optical fibre.
+- 7) A filter is installed on the customer premises so as to protect customer transmission equipment from being affected by the test light and to locate breakdown close to customer premises by detecting change in reflection from the filter.
+- 8) A water sensor is installed at the optical fibre cable joints to detect the presence of water.
+
+The operations terminal is connected to the TEM in the central office via the server and data communication networks. Under the direction of the Operations Terminal, the TEM controls the Fibre Selector so as to select any of the optical fibres for the purpose of performing the various types of tests. The test light from the TEM is injected into the optical fibre cable by the TAM, making it possible to conduct various tests.
+
+A water sensor is installed at the joints of the optical fibre cable, making it possible to detect the submergence of the joints in water by running an OTDR test.
+
+A filter is placed immediately in front of the transmitter on the customer premises so as to block the testing light and prevent any effect on the communication lines, thus making in-service testing possible.
+
+The general configuration of the system is described in Figure II.3.
+
+
+
+This diagram illustrates the overall system configuration. At the top, a 'System Manager' (containing a 'Server & DB') and a 'Maintenance Center' (containing an 'Operations Terminal') are connected via a 'Data Communication Network (DCN)'. The 'DCN' is also connected to a 'Central Office'. Inside the 'Central Office', there is a 'Controller', a 'Test and Measurement Equipment (OTDR, light source etc.)', and a 'Frame and Test Equipment Instrument Selector (FTES)' which are part of a 'TEM'. The 'Controller' is connected to an 'FTM' (Fibre Test Module) which contains a 'Fibre Selector' and a 'TAM'. The 'FTM' is connected to an 'Optical Fibre Cable'. This cable has a 'Cable joint' and a 'Water Sensor'. The cable continues to 'Customer Premises or Central office', where it passes through a 'Filter' to an 'ONU, etc.'. The text 'T0605200-01' is at the bottom right. Below the diagram, the text 'ONU Optical Network Unit' is provided.
+
+Overall system configuration diagram showing connections between System Manager, Maintenance Center, Data Communication Network (DCN), Central Office (containing Controller, TEM, FTM), Optical Fibre Cable, Cable joint, Water Sensor, and Customer Premises or Central office (containing ONU, etc., Filter).
+
+Figure II.3/L.40 – Overall system configuration
+
+### II.2.4 Control system overview
+
+The Operations Terminal and the TEM can communicate via the data communication network. One Operations Terminal can control multiple TEMs. One TEM can control multiple Fibre Selectors.
+
+An overview of the control system is given in Figure II.4.
+
+
+
+This diagram shows the control system architecture. A 'Server & DB' and an 'Operations Terminal' are connected to a 'Data Communication Network (DCN)'. The 'DCN' is connected to a 'TEM' (Test and Equipment Module). The 'TEM' contains a 'Controller', 'Test and Measurement Equipment (OTDR, light source, etc.)', and a 'Frame and Test Equipment Selector (FTES)'. The 'Controller' is connected to the 'FTES', which in turn is connected to multiple 'Fibre Selector' units. The text 'T0605210-01' is at the bottom right.
+
+Control system diagram showing connections between Server & DB, Operations Terminal, Data Communication Network (DCN), TEM (containing Controller, Test and Measurement Equipment, FTES), and multiple Fibre Selectors.
+
+Figure II.4/L.40 – Control system
+
+### II.2.5 Testing and measurement principles
+
+#### II.2.5.1 OTDR test
+
+In the OTDR test, a test light from the TEM is injected into a communication line by the TAM to determine the status of the optical cable section. The test light is blocked at the customer premises by a filter, so the test light does not affect the customer's communication.
+
+An overview of the OTDR test is given in Figure II.5.
+
+
+
+Central Office
+
+TAM
+
+Transmission Equipment λ1 F1 (Built-in Filter)
+
+Optical Fibre Cable Optical Fibre Cable
+
+Customer Premises
+
+F1 ONU, etc.
+
+Filter
+
+Fibre Selector
+
+λ2
+
+F2 (Built-in Filter)
+
+OTDR
+
+T0605220-01
+
+Diagram of an OTDR test setup showing the connection from the Central Office to Customer Premises. The Central Office contains Transmission Equipment connected to a TAM (Test Access Module) which includes a built-in filter F1 and a Fibre Selector. An OTDR is connected to the Fibre Selector through a built-in filter F2. The TAM connects to Optical Fibre Cables. At the Customer Premises, the line passes through a filter F1 before reaching the ONU, etc.
+
+F1 λ1 Band-pass filter
+
+F2 λ2 Band-pass filter
+
+**Figure II.5/L.40 – OTDR test**
+
+#### II.2.5.2 Section loss test
+
+A test light from the TEM for measuring loss in the fibre is injected into the transmission line by the TAM and its optical power is measured by a handy power meter either at the terminal on the customer premises or at an intermediate cable joint.
+
+An overview of the section loss test is given in Figure II.6.
+
+
+
+Central Office
+
+TAM
+
+Transmission Equipment
+
+Optical Fibre Cable Optical Fibre Cable
+
+Customer Premises
+
+Handy Optical Power Meter
+
+Fibre Selector
+
+λ2
+(1310 nm, 1550 nm)
+270 Hz Modulation
+
+Light
+
+T0605230-01
+
+Diagram of a section loss test setup. Similar to the OTDR test, it shows the Central Office with Transmission Equipment and a TAM. Instead of an OTDR, a Light source with λ2 (1310 nm, 1550 nm) and 270 Hz Modulation is connected to the Fibre Selector. At the Customer Premises, the Optical Fibre Cable connects to a Handy Optical Power Meter.
+
+**Figure II.6/L.40 – Section loss test**
+
+#### II.2.5.3 Fibre identification
+
+The light is injected into the in-service fibre via the TAM. And a Fibre identifier detects leaked light. An overview of fibre identification is given in Figure II.7.
+
+
+
+The diagram illustrates the fibre identification process. In the Central Office, Transmission Equipment sends a signal at wavelength $\lambda 1$ through a TAM (Transmission Access Module). The TAM contains a built-in filter (F1) and a Fibre Selector. A Light Source, modulated at 270 Hz, is connected to the Fibre Selector and injects light at wavelength $\lambda 2$ into the optical fibre. The optical fibre cable runs to the Customer Premises. A Fibre Identifier is shown detecting leaked light at wavelength $\lambda 2$ from the fibre. In the Customer Premises, the signal passes through another filter (F1) to an ONU (Optical Network Unit) or other equipment. The diagram is labeled T0605240-01.
+
+Diagram of fibre identification setup showing Central Office, Optical Fibre Cable, and Customer Premises.
+
+F1 $\lambda 1$ Band-pass filter
+
+Figure II.7/L.40 – Fibre identification
+
+#### II.2.5.4 Optical power monitoring
+
+A communication light (1310 nm/1550 nm) between transmission equipment and an ONU is split by the TAM and its optical power is measured by an optical power meter to check the status of the inside optical cable section.
+
+An overview of optical power monitoring is given in Figure II.8.
+
+
+
+The diagram illustrates the optical power monitoring setup. In the Central Office, Transmission Equipment sends a signal at wavelength $\lambda 1$ through a TAM. The TAM contains a built-in filter (F1) and a Fibre Selector. An Optical power meter is connected to the Fibre Selector via a filter (F1) to measure the optical power of the signal. The optical fibre cable runs to the Customer Premises. In the Customer Premises, the signal passes through another filter (F1) to an ONU (Optical Network Unit) or other equipment. The diagram is labeled T0605250-01.
+
+Diagram of optical power monitoring setup showing Central Office, Optical Fibre Cable, and Customer Premises.
+
+F1 $\lambda 1$ Band-pass filter
+
+Figure II.8/L.40 – Optical power monitoring
+
+## **II.3 Mandatory conditions**
+
+The system shall be capable of testing the following facilities.
+
+### **II.3.1 Network topologies**
+
+The system is for testing the optical access networks and trunk networks.
+
+The testable topologies of the access network shall be the single star configuration, the passive double star configuration, and the ring configuration (cable ring and SDH ring). If an optical splitter is installed outside the central office, then the passive double star configuration shall be testable up to the splitter.
+
+The testable topologies of the trunk network shall be the single star configuration.
+
+### **II.3.2 Capacities**
+
+The components of the system shall be capable of accommodating equipment as specified below.
+
+- 1) The server shall be capable of accommodating 100 000 optical fibres.
+- 2) The TEM shall be capable of accommodating max. 10 000 optical fibres.
+- 3) The FTM shall be capable of accommodating max. 2000 optical fibres for access networks and max. 600 optical fibres for trunk networks.
+- 4) The Fibre Selector shall be capable of accommodating max. 2000 optical fibres for access networks and max. 600 optical fibres for trunk networks.
+
+### **II.3.3 Test wavelength**
+
+It shall be possible to conduct the following tests at the wavelength specified below for each test.
+
+- 1) OTDR test 1310 nm, 1550 nm and 1650 nm
+- 2) Section loss test 1310 nm and 1550 nm
+- 3) Fibre identification 1550 nm and 1650 nm
+
+### **II.3.4 System data management**
+
+The system shall be capable of storing data for use in the direction of remote testing and test result confirmation.
+
+#### **II.3.4.1 Data for use in testing**
+
+The system shall be capable of storing the items of data listed below.
+
+- 1) Central office name.
+- 2) Cable name.
+- 3) Fibre number.
+- 4) Cable length.
+- 5) Jointing point.
+- 6) Additional information (e.g. man-hole name, service number).
+
+#### **II.3.4.2 Test results**
+
+The system shall be capable of storing the results of one OTDR test and section loss test for each optical fibre.
+
+#### **II.3.4.3 Loss and reflection measurement**
+
+The system shall determine from the OTDR test the location of a cable joint and distinguish whether the joint is a fusion splice or a connector. It shall calculate the loss and display the result on the screen of the Operations Terminal.
+
+The system shall compare the calculated coupling loss and reflection with reference values for each connection type specified within the system. If calculated coupling loss is over the reference values, the system shall send a warning to the screen of the Operations Terminal.
+
+The system shall be capable of displaying the measurement results together with stored test results.
+
+### **II.3.5 Interface**
+
+#### **II.3.5.1 Interface between the server and the Operations Terminal and between the server and the TEM**
+
+The interface between the server and the Operations Terminal and between the server and the TEM shall employ data communication networks, e.g. ISDN.
+
+#### **II.3.5.2 Interface between the server and other systems**
+
+The server shall be able to get outside plant data from the outside plant database system via data communication networks.
+
+# **APPENDIX III**
+
+## **Optical fibre outside plant maintenance support and testing system**
+
+## **Abstract**
+
+This appendix, based on the Italian experience and on information collected by European operators, deals with the benefits offered by an optical fibre cable supervisory system based on the principle of continuous monitoring of attenuation. The purpose is to describe the requirements, the system architecture and the GUI (Graphical User Interface) features of this kind of optical cable supervisory system.
+
+## **III.1 Introduction**
+
+The OTDR-based monitoring systems are capable of periodic measurements of the fibres' attenuation coefficient and, when integrated with transmission equipment alarms, they are capable of immediate reporting fault location data in case of cable damage.
+
+Other monitoring systems, through the continuous monitoring of the power level received at the end of the optical fibre (just before the receiving equipment), are able to collect and store power-level data and provide an immediate detection of fibre faults through the activation of an OTDR function when the monitored power decreases below a certain level.
+
+Both these systems are designed to minimize the service outages as well as the economic loss through the immediate location of failures at alarm generation and, at different degrees, are intended to predict failures due to the degradation of fibre performance.
+
+The proposal of this appendix, based on practical solutions from the Italian experience, aims to provide a description of an integrated and comprehensive approach to the optical cable network supervision in order to enhance preventive maintenance capabilities of the most valuable resource in the network – the optical fibre, adding to the aforementioned solutions the integration of the continuous monitoring on the fibre optical attenuation.
+
+## III.2 Scenario
+
+Fibre optic business is evolving rapidly worldwide, and new scenarios are arising.
+
+As regards outside plant maintenance, not only incumbent network operators must be taken into account, but also new actors which may have different needs and perspectives with respect to the management of fibre optic cables.
+
+In order to have a reference scheme, the most important actors and their perspectives are listed in Table III.1.
+
+**Table III.1/L.40 – Actors and perspectives for outside plant maintenance**
+
+| Actors | Perspective |
+|--------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Incumbent Network Operators | Main business: transport of the service traffic. They provide operation and maintenance of their own optical networks. They own the transmission systems and the optical cables. Their main goal is to get a better quality of maintenance activities with reduced costs. |
+| Newcomers (e.g. utilities – gas, water and energy suppliers – railways and highways) | Main TLC business: service provisioning (IP, bandwidth or dark fibre). They own an optical infrastructure already deployed, but they are starting with the provisioning/selling of TLC services, including dark fibre leasing. Often they do not have a proper maintenance organization able to completely manage the outside plant and they may decide to pay for outsourcing maintenance activities. As for dark fibre leasing, they have to comply with contracts, where bearer availability parameters are put into as a physical-level SLA. |
+| Installation and maintenance companies | Main business: installation, bringing-into-service, surveillance and repair services. They provide these services to both incumbent and new operators, and they have to guarantee a defined quality of the installation/maintenance services. Their main goal is to comply with contracts' requirements relevant to parameters such as Time-To-Locate, Time-To-Repair, which are getting increasingly strict. |
+
+For all the categories listed above, the approach to preventive maintenance is very important especially in an ever increasing competitive market, where the quality of service can be a business leverage.
+
+## III.3 Benefits of attenuation continuous monitoring
+
+As regards preventive maintenance, whose principles are described in ITU-T L.25, continuous monitoring of optical fibres' performance (based on attenuation detection through the measure of a fraction of the optical power flowing along the fibre) provides the following benefits:
+
+### - **Fault/anomaly complete detection capabilities**
+
+All degradation phenomena producing a loss increase are detected, independently from their duration and nature, which may not affect, at a first stage, DWDM or SDH service. This feature allows an important cost saving: in fact, when degradation gets worse repair activities are more complex, in particular when the first warnings of a potential critical situation consist of transient effects (e.g. strong vibrations on splices) that are not detected by periodic measurements.
+
+Up to 20% of preventable faults shows an initial stage where anomalies can be completely detected only by attenuation continuous monitoring.
+
+### - **Non-intrusiveness**
+
+Continuous monitoring on in-service traffic based on tapping and measuring a small fraction of the signal avoids the use of external, high power optical pulses to be inserted into the fibre at a different wavelength. OTDRs are necessary for event location function when a problem occurs, but they should not be used for in-service activities, because of both their potential intrusive characteristics and the operational requirements of WDM and Optical Filters.
+
+In particular, if continuous monitoring applies, OTDR can be used only on a subset of fibres (typically dark ones) with a statistical coverage of all the cable events: it is estimated that one fibre per internal tube/groove can highlight an average of more than 90% of sudden faults (cable cuts), reducing system costs and granting service security with respect to intermodulation phenomena. This is very important, taking into account that new transmission systems will emit higher power signals and enlarged spectrum.
+
+### - **Real-time fault location**
+
+Continuous monitoring of fibre attenuation guarantees immediate activation of location OTDR measurement, in a far more reliable and quick way than any other measurement techniques, which try to cope with real-time response to faults by the integration of equipment relay alarm contacts. Since relay alarm contacts generally provide very poor information about the faulty fibre, the integration between equipment and cable maintenance support system may be complicated and transmission technology life-cycle is quite shorter than optical OSP lifetime; so an autonomous system, providing fastest reaction to faults, should be a better solution, even when SDH and DWDM protection schemes are operating. In Europe, customers show a great interest in achieving a reliable and immediate separation between cable or equipment responsibility when a fault occurs; furthermore, they fix requirements, in terms of time-to-locate, to post-fault maintenance activities, which can be assigned to both internal and external staff. It is estimated that the identification of a trouble in the optical network, performed by a preventive maintenance support system based on continuous attenuation monitoring, saves more than one hour than systems based on periodic measurement, not integrated with service alarms. Real-time fault location based on continuous attenuation monitoring is even more important for third party companies providing installation and maintenance services to the optical infrastructure's owners. They can provide a better service and be compliant with lower intervention times if they are completely independent in supervisioning the optical network. Some recent contracts for optical network maintenance state that the maintenance provider shall guarantee less than three hours to reach the faulty point, sometimes with no visibility on transport quality parameters available to the network operator through the transmission management system. Continuous attenuation monitoring allows them to anticipate network operators alarm notifications and to respect the maintenance contract with lower investment in the in-field maintenance crew.
+
+### - **Dark fibre leasing quality control**
+
+Following the United States market trend, the European market of dark fibre leasing is gaining importance, since a lot of new actors bought dark fibres in order to get an operating optical network, avoiding problems and delays related to outside plant deployment. Continuous and non-intrusive attenuation monitoring can represent the best way for dark fibre owners to be sure of the profitability of their asset and to comply with SLA contracts, including the penalties foreseen when the level of "bearer availability" is not reached. This is very important because the new actors usually cannot make any assumption based on when the customer is going to transport information on their fibres and they would not like to rely on customer complaints to determine this. Moreover attenuation monitoring represents a value added option (and thus a competitive leverage) in the dark fibre offering.
+
+Table III.2 is intended to cross-correlate actors and attenuation continuous monitoring key-benefits.
+
+**Table III.2/L.40 – Cross-correlation among actors and monitoring key-benefits**
+
+| | Fault/anomaly complete detection capabilities | Non-intrusiveness | Real-time fault location | Dark fibre leasing quality control |
+|------------------------------------|------------------------------------------------------|--------------------------|---------------------------------|-------------------------------------------|
+| Incumbent Network Operators | Important | Important | Important | – |
+| Newcomers/Dark fibre providers | Important | Important | Important | Very important |
+| Installation/maintenance companies | – | Important | Vital | – |
+
+## III.4 Basic principles of the optical cable supervisory system
+
+The optical cable supervisory system proposed in this appendix is based on the fundamental concept of the continuous monitoring of optical attenuation.
+
+Attenuation is calculated by measuring optical power levels at both ends of the optical fibre, before the transmission equipment, and calculating the relevant power loss. Attenuation represents the key parameter of optical fibre performance, because fibre attenuation degradation is the most dangerous threat to the profitability of the most important investment in optical networks.
+
+Continuous monitoring of attenuation on both out-of-service (dark) and in-service (lit) fibres (in the last case without affecting service traffic) allows a full-time surveillance of this key parameter, introducing complete detecting capabilities of all type of degradation effects, whatever nature and duration they have. In particular both casual and periodic optical power loss variations or fluctuations, even if very rapid, can be detected and an accurate analysis of the problem can be performed prior to the transmission equipment alarm generation and consequent user acknowledgement.
+
+Moreover, continuous monitoring of optical attenuation can automatically activate an OTDR function in order to perform fault and degradation location when a sudden power loss along the cable is detected.
+
+## III.5 Requirements of the optical cable supervisory system
+
+The integrated optical cable supervisory system shall be designed according to a general principle of complete transparency towards the optical network it has to supervise.
+
+In particular, considering the forecast of one or more transmission equipment upgrades during the expected lifetime of the optical cable (25-30 years) and the current evolution trend in optical transmission technology, an optical cable supervisory system must guarantee the transparency over all the available optical band. In this way the installed supervisory system will not set limitations on the operating windows that optical transmission technology will demand in the future to the installed optical fibre.
+
+As far as **maintenance objectives** are concerned, the most important are:
+
+- a clear separation between transmission equipment and optical cables management responsibility; in particular, as for leased fibres, a clear distinction of responsibility between cable owners and fibre leaseholders;
+- the availability of a fibre quality level certification tool, wherever a boundary between operators or between a customer and an operator is defined;
+
+- system independence from equipment alarms;
+- provision of an easy-to-use tool for a real-time identification of degradation effects in the optical network, in order to help operators to perform an effective preventive maintenance process;
+- provision of an easy-to-use tool for a real-time identification and precise location of faults, in order to support operators in the corrective maintenance procedures' activation;
+- provision of a comprehensive trend analysis tool, able to continuously capture optical network performance data; these performance data can be used for the evaluation of:
+ - network optical cables potential profitability;
+ - quality of materials;
+ - installation procedures.
+
+The **main features** of the optical cable supervisory system allowing the attainment of the mentioned maintenance objectives are listed below:
+
+- **non-intrusiveness** on the service traffic, due to the design of a completely passive optical probe: non-intrusiveness is a key characteristic of the monitoring system, especially where cable owners are not permitted to adopt an OTDR-based monitoring process on in-service fibres (e.g. leased fibres);
+- **sensitivity** to even very rapid degradation effects, which can have a negative influence on optical fibre performance in the long period (e.g. mechanical vibrations due to road and railway traffic);
+- **real-time alarm reporting**: optical power and attenuation threshold-crossing events are immediately detected and reported to the system presentation interface, in order to fully exploit preventive maintenance capabilities;
+- **automated OTDR measurement activation** when a threshold-crossing event referring to a variation of attenuation is reported, in order to have a minimum location time when a sudden fault or anomaly is faced;
+- **permanent storage of monitoring results** and fibre reference traces, in order to enable a powerful analysis of the optical fibre attenuation trend;
+- **modularity and easiness of installation** of optical probes along the optical cables;
+- **system cost-effectiveness** with respect to different network topologies, ranging from trunk networks to access networks and leased fibres;
+- **scalability** in terms of number of managed network elements and of available functions.
+
+### System architecture
+
+Figure III.1 shows overall system configuration.
+
+
+
+The diagram illustrates the overall system configuration for optical network monitoring. At the top, three **Presentation Workstations** are connected to **NMC A**. **NMC A**, along with **NMC B** and **NMC C** (each containing two terminals), are connected to a central **OS** (Operating System). The **OS** is connected to a **DCN** (Data Communication Network). The **DCN** is connected to two types of remote units: an **RMTU** (Remote Monitoring and Testing Unit) and an **RMU** (Remote Monitoring Unit). The **RMTU** contains two functions: **Optical Power Level Monitoring Function** and **Fibre Fault Location and Degradation Function**. The **RMU** contains the **Optical Power Level Monitoring Function**. Both units are connected to **Transmission equipment** at the **Transmitting end** and **Receiving end**. The **Transmission equipment** includes an **OGM** (Optical Generation Module), **OP** (Optical Probe), and **Osm** (Optical switch). The diagram also shows **In-service fibres** and **Out-of-service fibres**, and **OTDR Testing** capability. A reference number **T0605260-01** is present in the bottom right.
+
+**OGM** Optical Generation Module
+**OP** Optical Probe
+**Osm** Optical switch
+**RMTU** Remote Monitoring and Testing Unit
+**RMU** Remote Monitoring Unit
+
+Overall system configuration diagram showing the network management and monitoring architecture. At the top, Presentation Workstations are connected to NMC A, which is connected to a central OS. NMC B and NMC C are also connected to the OS. The OS is connected to a DCN (Data Communication Network). The DCN is connected to RMTU (Remote Monitoring and Testing Unit) and RMU (Remote Monitoring Unit). The RMTU and RMU are connected to Transmission equipment at the Transmitting end and Receiving end. The RMTU contains Optical Power Level Monitoring Function and Fibre Fault Location and Degradation Function. The RMU contains Optical Power Level Monitoring Function. The Transmission equipment includes OGM (Optical Generation Module), OP (Optical Probe), and Osm (Optical switch). The diagram also shows In-service and Out-of-service fibres, and OTDR Testing. A reference number T0605260-01 is present.
+
+**Figure III.1/L.40 – Overall system configuration**
+
+- All the system management functions, i.e. attenuation monitoring, testing and surveillance functions, should be performed by a centralized Operating System (OS); the OS should also manage the databases necessary to the system operation.
+ - Network Maintenance Centres (NMCs) should be located where monitoring, testing and surveillance activities are requested; these activities should be performed using Operation Terminals.
+ - Remote Controlled Units, located at the network nodes where optical cables are terminated, should perform monitoring and testing activities. The functions performed by the mentioned units should be the following:
+ - a) optical power level monitoring function;
+ - b) fibre fault and degradation location function.
+- Depending on the surveillance requirements of each node, monitoring and testing functions should be grouped in a single mechanical unit that constitutes the Remote Controlled Unit; the most usual types of Remote Controlled Units should be:
+- Remote Monitoring and Testing Unit (RMTU), containing a) and b) monitoring functions.
+ - Remote Monitoring Unit (RTU), containing a) monitoring functions.
+
+- The optical power level monitoring function a) should be performed by Optical probes (Ops) which are based on a splitter device tapping a small portion of light and measuring indirectly the optical power level of the whole light carried on the fibre.
+
+Particular care should be taken in designing the probes, so that maintenance activities (e.g. substitution of faulty parts) shall not affect the service traffic.
+
+- Remote Controlled Units (RMTUs or RMUs) collect optical power values from the Ops; the OS is in charge of calculating the fibre attenuation, calculating power values referring to the end of the fibre.
+- As for out-of-service fibres, the optical power level monitoring function a) should be enabled, by means of an Optical Generation Module (OGM), designed to inject a reference light into the dark fibre.
+- The Optical probes (Ops) should access to any number of fibres in the cable, according to customer's requirements.
+
+In particular, all in-service fibres and a proper selection of dark fibres in a cable (considering cable geometry and structure) should be monitored in order to achieve a good characterization of the optical cable.
+
+- Continuous monitoring of fibre attenuation should provide complete detection capabilities over all degradation effects, whatever nature and duration they have. So preventive maintenance is able to achieve early troubles' notification, prior to the transmission equipment alarm generation and prior to the consequent user acknowledgement.
+- OTDR-based fibre fault location function b) should be performed on all the monitored fibres of the cable. Location measurements on in-service fibre require installation of WDMs in order to prevent effects of high optical OTDR pulses on the transport traffic. For economic reasons, a subset of the monitored fibres should be considered for location purpose. The selection of the location fibres should follow basically cable geometry and structure (e.g. one fibre per bundle or even just one fibre per cable). System costs are optimized if dark fibres are chosen for location. This approach is justified by the following reasons:
+ - most of the non-preventable faults (e.g. dig-ups) have a high probability to affect all the fibres of the same cable and so the OTDR automatic function, using just few fibres or even just one fibre per each cable, can guarantee a good coverage of fault location in a cost-effective way;
+ - attenuation continuous monitoring grants preventable fault and degradation detection on all the monitored fibres, so Maintenance Centres are always and promptly alerted. When degradation phenomena affect only a subset of the fibres in the cable and consequently OTDR automatic fault location cannot be properly used, maintenance and location operation could be scheduled before a fault location occurrence. Manual set-up of OTDR based fibre fault location function b) should be also used for focused test.
+
+### GUI features
+
+The OS is based on a client-server architecture with centralized server functions and a number of clients geographically distributed accordingly to network operators' organizational needs.
+
+The main OS functions are listed below:
+
+- GIS (Geographic Information System).
+- Easy-to-use tools for the configuration of the supervisory system equipment and the access to the optical network.
+- Monitoring threshold configuration, applying to optical attenuation/power level.
+- Real-time highlights of anomalies and faults.
+
+- Direct access to the optical data generated by the probes at the optical link ends: real-time display of both fibre and cable attenuation (global view of attenuation values of all the fibres in the cable).
+- Views of monitoring results stored in OS database.
+- Trend analysis tools.
+- Integrated view of the overall network status.
+- Automatic OTDR measurement at configured threshold crossing, detected by the monitoring system (immediate fault/degradation location).
+- OTDR measurements on user's request.
+- Optical fibre trace management: view of the last trace of an optical fibre, automatic comparison with the baseline trace, permanent storage in a standardized format of multiple traces per fibre, event characterization (connectors, splices, etc.).
+- Complete system auto-diagnostics management.
+
+## III.6 Conclusions
+
+This appendix is addressed to present the Italian experience about the principles and requirements needed for an optical cable monitoring system.
+
+The main advantage of a completely autonomous system is the capability to integrate a full-coverage approach with respect to preventive maintenance.
+
+It allows:
+
+- continuous monitoring of the optical link attenuation, non-intrusive on in-service fibres;
+- fault/degradation location on demand, applying preferably on an out-of-service fibre per cable;
+- permanent storage of all the collected data.
+
+It offers considerable advantages relevant to:
+
+- the definition of a reliable management competence over optical links;
+- the implementation of an effective preventive maintenance procedure, guaranteeing the optical carrier service level;
+- the progressive deployment of the supervisory system thanks to the modularity of its elements and the reduced impact on central office plants;
+- the scalability of the system according to the number of managed optical cables and nodes, providing smart solutions for both small and large networks.
+
+# APPENDIX IV
+
+## **The Indonesian experience on optical fibre cable operation and maintenance support system**
+
+## IV.1 Introduction
+
+Optical fibre cables have been extensively used in the telecommunications network to support high speed and broadband communications services. In the future, optical access network will be widely deployed due to its high potential to provide many kinds of services for both business and ordinary customers.
+
+This appendix introduces the Indonesian experience in optical fibre operation and maintenance support system which is developed for effective and efficient operation and maintenance activities, and also to keep a high reliable optical access network.
+
+## IV.2 Fundamental requirements
+
+The optical fibre cable operation and maintenance support system shall support various tasks involved in the constructions of optical fibre cables and installation on the customer's premises before they are put in service. After optical fibre cables are in service, it shall support the work of fault detection and repair, periodic fibre monitoring, and changing over of fibres.
+
+The system supports several measurement functions such as described in Table IV.1:
+
+**Table IV.1/L.40 – System's measurement functions**
+
+| Measurement | Test method | Purpose of test |
+|---------------------------------------------|-----------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Loss and Reflection of Connection and Cable | OTDR | Measuring loss and reflection at cable jointing Judging test result based on reference value of loss and reflection Locating fault Measuring loss and reflection fluctuation cause by deterioration at cable jointing |
+| Section Loss | Light Source and Power Meter | Measuring section loss of fibre optic cable Judging test result based on reference value of section loss |
+| Fibre Identification | Light Source and Fibre Identifier | Identification of a designated fibre at cable jointing or cable end |
+
+## IV.3 System's basic configuration
+
+The measurement system's physical networks consist of 3 layers (see Figure IV.1):
+
+- System Layer, consists of Operations Terminal and Database.
+- Data Communication Layer, consists of public telecommunications network and modems.
+- Facilities Layer, consists of optical components such as coupler, water sensor, filter, fibre selector, and test measuring instrument. The optical coupler is connected to each fibre to be tested. Optical couplers are arranged inside Test Access Modules (TAMs) which are installed within Fibre Termination Module. Test light is inserted into fibre through fibre selector and the coupler. The Test Equipment Module (TEM) includes the fibre selector, main controller, and test measuring instrument such as OTDR and Light Source. The main Controller is a personal computer supported by a database whose functions are to control test measuring instruments and process the measurement data automatically.
+
+
+
+FTM Fibre Termination Module
+ OLT Optical Line Termination
+ ONU Optical Network Unit
+
+T0605120-01
+
+Diagram of the system's basic configuration showing three layers: System layer, Data Comm. layer, and Facilities layer. The System layer contains an O&M centre with an Operations Terminal and a Database. The Data Comm. layer contains a Public Switch Telephone Network connected to a Modem. The Facilities layer contains a Test Equipment Module, OLT, FTM, Optical Cable, Coupler, Closure, Water sensor, Filter, and ONU. Arrows show the flow of data from the Operations Terminal through the network and modem to the Test Equipment Module and then to the optical cable components.
+
+**Figure IV.1/L.40 – System's basic configuration**
+
+## IV.4 Functions of main units
+
+The optical fibre cable operation and maintenance support system consists of three main units:
+
+- Operations Terminal.
+- Test Equipment Module.
+- Fibre Termination Module.
+
+Detailed functions of each main unit are described in Table IV.2.
+
+**Table IV.2/L.40 – Functions of the main units**
+
+| No. | Main unit | Function |
+|------------|--------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 1 | Operations Terminal | • Registers, enquires and changes data required in performing the test and information on each unit. Also deletes those that are no longer required. • Instructs test for the specified fibre, displays the test result, and outputs it as a document. |
+| 2 | Test Equipment Module (TEM) | • Controls the test equipment according to instructions from the operations terminal, tests optical fibre, analyses the test result, and sends the result to the operations terminal. • Performs periodical OTDR test for specified fibre at the specified interval, according to instructions from the operations terminal. Also sends the test result to the operations terminal. |
+| 3 | Fibre Termination Module (FTM) | • Selects fibre to be tested from multiple optical fibres terminated according to instruction from the TEM. |
+
+## **IV.5 System's hardware configuration**
+
+The system's hardware configuration is shown in Figure IV.2 below.
+
+
+
+Figure IV.2/L.40 – Hardware Configuration. This schematic diagram illustrates the hardware setup for an optical fibre cable O&M support system. At the top, two identical units are shown: a standard FTM (Fibre Terminal Module) and a Remote FTM. Each unit contains a Filter, a TAM (TAM \*1), a block of 601 Fibres, and a Controller. These units are connected via Optical Fibre Cables to a central switching system. The FTM's Controller connects to an FS (1 x 601 SW) via an Extension Cable. The Remote FTM's Controller connects to the same FS via a Trunk Cable. The FS is part of a larger system containing an FTES (1 x 21 SW) with a Measurement Port (\*1), an OTDR/LS, a SW-Controller, a Main Controller, a TEM, and a Modem. The Main Controller is connected to an Operation and Maintenance Center via a MODEM, which in turn connects to an Operations Terminal. A legend at the bottom left defines the line types: Analogue leased (light grey), Control line (thick black), and Fibre (thin black). The code T0605130-01 is noted in the bottom right of the diagram area.
+
+**Figure IV.2/L.40 – Hardware Configuration**
+
+## IV.6 General specification of optical fibre cable O&M support system
+
+The optical fibre operation and maintenance support system shall satisfy the following conditions.
+
+### IV.6.1 Test scope
+
+The system is basically for testing the optical access network.
+
+The testable topologies of the network between the telephone office and the facilities on the customer premises shall be the single star configuration, the passive double star configuration, and the ring configuration (cable ring and SDH ring). If an optical splitter is installed outside the telephone office, then the passive double star configuration shall be testable up to the splitter.
+
+Application to trunk facilities shall also be considered.
+
+### IV.6.2 Capacities
+
+The components of the system shall be capable of accommodating equipment as specified below.
+
+- a) The Operations Terminal shall be capable of controlling 10 TEMs.
+- b) The TEM shall be capable of accommodating 20 FTMs.
+- c) The FTM shall be capable of accommodating 600 optical fibres.
+- d) The Fibre Selector shall be capable of accommodating 600 optical fibres.
+
+### IV.6.3 Test wavelength
+
+It shall be possible to conduct the following tests at the wavelength specified below for each test.
+
+- a) OTDR test 1650 –10, +20 nm
+- b) Section loss test 1650 –10, +20 nm
+- c) Fibre identification 1650 –10, +20 nm
+
+### IV.6.4 Test distance restrictions
+
+The restrictions on testing distance are as specified in Table IV.3.
+
+**Table IV.3/L.40 – Testing distance**
+
+| Test | Maximum distance | Measurement conditions |
+|----------------------|------------------|-----------------------------------------------------------|
+| OTDR test | 20 km | Wavelength: 1650 –10, +20 nm Pulse width: 1 µs or less |
+| Section loss test | 20 km | Wavelength: 1650 –10, +20 nm Modulation light: 270 Hz |
+| Fibre identification | 20 km | Wavelength: 1650 –10, +20 nm Modulation light: 270 Hz |
+
+### IV.6.5 System data management
+
+The system shall be capable of storing data for use in the direction of remote testing and test result confirmation.
+
+The system shall be capable of storing the items of data listed below as data for use in testing.
+
+- a) TEM number.
+- b) Fibre Selector number.
+- c) Fibre number.
+- d) Cable number.
+- e) Additional information (e.g. cable length).
+
+The system shall be capable of storing the results of one OTDR test and section loss test for each optical fibre.
+
+### IV.6.6 Coupling loss and reflection measurement
+
+The T-AURORA system shall determine from the OTDR test the location of a cable joint and distinguish whether the joint is a fusion splice or a connector. It shall calculate the coupling loss and display the result on the screen of the Operations Terminal.
+
+The system shall compare the calculated coupling loss and reflection with reference values for each connection type specified within the system. If calculated coupling loss is over the reference values, the system shall send a warning to the screen of the Operations Terminal.
+
+The system shall be capable of displaying the measurement results together with stored test results.
+
+### IV.6.7 Transmission conditions
+
+The interface between the Operations Terminal and the TEM shall employ analogue telephone lines.
+
+The TEM shall be able to control remotely located Fibre Selectors.
+
+The maximum distance at which communication between the TEM and the Fibre Selector is possible shall be 10 km.
+
+### IV.6.8 System use conditions
+
+It shall be possible to use each of the components of the system other than the Water Sensor under the environmental conditions listed below.
+
+- a) Ambient temperature 10° C to 50° C
+- b) Humidity 20% to 95% RH with no condensation
+- c) Power supply 220 V AC $\pm$ 10% (single phase, 50 Hz)
+
+## IV.7 Application software
+
+The application software will be installed on personal computers at the Operation and Maintenance Centre and central office. The main functions of the application software are described in Table IV.4.
+
+**Table IV.4/L.40 – Main system functions of application software**
+
+| No. | Function | Description |
+|-----|---------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 1 | Test Operations | • Performs the OTDR test, Section Loss test, and Fibre Identification remotely from the operations terminal. • Performs the periodical OTDR test to determine whether fibres are normal. |
+| 2 | Test data and result management | • Registers, enquires and changes data required in performing the tests. Also deletes data that are no longer required. • Outputs the test result of fibres and prints the result. |
+| 3 | Security | • Registers, enquires, changes and deletes information of operations terminal. • Registers, enquires, changes and deletes information of operator (end user). |
+| 4 | System reports management | • Enquires fibre alarms detected during the continuous OTDR test or periodical test. • Enquires failures caused in the TEM. |
+
+The detailed functional configuration of application software is shown in Figure IV.3.
+
+
+
+| | | | | |
+|-----------------------------------|------------------------------------|------------------------------------------|-------------------------|----------------------------------------------|
+| Functions of application software | 7.1 | Test Operations Function | 7.1.1 | Fibre Identification |
+| | | | 7.1.2 | Section Loss test |
+| | | | 7.1.3 | OTDR test |
+| | | | 7.1.4 | Continuous OTDR test |
+| | | | 7.1.5 | Preventive Maintenance |
+| | | | 7.1.6 | Result reception |
+| | 7.2 | Test Data and Result Management Function | 7.2.1 | Central office information management |
+| | | | 7.2.2 | Test equipment module information management |
+| | | | 7.2.3 | Fibre selector information management |
+| | | | 7.2.4 | Cable information management |
+| | | | 7.2.5 | Fibre information management |
+| | | | 7.2.6 | Test result management |
+| | 7.3 | Security Function | 7.3.1 | Operations terminal information management |
+| | | | 7.3.2 | Operator information management |
+| 7.3.3 | | | Password management | |
+| 7.4 | System Reports Management Function | 7.4.1 | Alarm history inquiry | |
+| | | 7.4.2 | Failure history inquiry | |
+
+Functional configuration of application software diagram showing four main functions: Test Operations Function, Test Data and Result Management Function, Security Function, and System Reports Management Function, each with its own sub-functions.
+
+**Figure IV.3/L.40 – Functional configuration of application software**
+
+# APPENDIX V
+
+## Spain's experience of an optical fibre monitoring system (OFMS)
+
+## V.1 Introduction
+
+The growing importance of transmission systems using optical fibre as a physical carrier is resulting in an increase in economic resources that telecommunication providers are dedicating to the corrective and preventive maintenance of those systems and carriers. The essential objective of such maintenance is to achieve the highest quality and best economic output from the said systems and carriers.
+
+Automatic and centralized monitoring systems, unlike manual operators, provide rational and exhaustive control of the plant or designated elements thereof.
+
+Existing automatic monitoring systems, dedicated to optical fibre monitoring, are based on the development of specific elements and the availability of optical switches with a large number of channels that, in conjunction with the gradual reduction in price of auxiliary passive elements, make for flexible systems at very competitive prices, with a high degree of modularity.
+
+In addition, the possibility of the system working in the fourth transmission window extends monitoring not only to fibres working in the second window but also to those working in the third and even in both.
+
+## V.2 General
+
+The basic parameters of an optical fibre from the point of view of transmission, are attenuation, which limits the length of the transmission path, and dispersion, which determines the bandwidth.
+
+The whole length of an optical fibre cable is exposed to an infinite number of sources of disturbance that mainly affect attenuation in the link; this is also influenced by the loss from typical interconnection components (splices and connectors).
+
+The easiest alternatives for monitoring an optical fibre cable are those based on measurement of its vacant fibres, since many degradations and breaks affect all the fibres in the cable. This means that monitoring one of these fibres provides general information on the condition of the cable with a reliability percentage above 60%.
+
+Nevertheless, exhaustive monitoring of the cable with a greater degree of reliability requires monitoring of fibres carrying traffic. This implies that the monitoring system wavelength is higher than that of the transmission equipment.
+
+## V.3 Optical fibre monitoring system (OFMS) – General description
+
+The optical fibre monitoring system used by Telefónica de España meets its demands and specifications. This makes for a system that is totally focused on monitoring and management of the optical fibre plant, with maximum output and efficiency in all its functions.
+
+The system manages the reception of alarms in the fibres when these are generated by breaks or degradations. The system also conducts a series of measurements aimed at identifying the state of the fibres at any time.
+
+The system is composed of all the optical fibre plant terminals (OFPT) strategically distributed over the plant to be monitored. These terminals collect information on the state of the fibres and, by comparing the actual state with a determined threshold, generate an alarm situation when the state referred to requires it.
+
+The information collected by the plant terminals assigned to a specified monitoring area is sent to the control centre responsible for maintenance and conservation of the area in question.
+
+## V.4 System performance
+
+Analysed from the operational point of view, the optical fibre monitoring system described in this appendix has the following functions:
+
+- Monitoring of vacant fibres as well as fibres in service by means of reflectometric techniques in the second, third and fourth transmission windows.
+- Detection and location (using the corresponding mathematical algorithm) of degradations and breaks in the fibres.
+- Automatic execution of measurements in the event of alarms in the line transmission equipment (LTE).
+- Execution of measurements on request from a higher hierarchy (remote control centre, operation site).
+- Recording of singular points (splices, manhole, etc.) that allow the events of the trace to be associated with their geographical location.
+- Assignment of vacant fibres to various transmission systems with the purpose of executing measurements in these fibres when any alarm occurs in the LTE and in regenerators that are not connected to the fibres.
+- Recording of historical and reference measurements enabling a provisional evolution analysis.
+
+- Capture of the reflectometric trace of the fibre.
+- Urgent and non-urgent alarm management, when attenuation of the link exceeds the acceptable threshold.
+- Execution of attenuation measurements in splices and reflection measurements in connectors.
+- Back-up optical fibre system enabling communication with control centres to be re-established through a secondary system, should the principal system fail.
+- Obtaining database texts and reports by means of Internet facilities.
+- Geographical information system that shows in graphic form information relating to the optical fibre plant at different levels (national, territorial and local) according to set parameters.
+
+## V.5 System
+
+The hardware architecture of the monitoring system required to carry out the functions defined in the previous clause is shown in Figure V.1.
+
+The diagram shows the following basic elements:
+
+- **Control system:** This element implements and controls all management, monitoring and control functions of the optical fibre plant.
+- **Remote control centre:** Controls the functionality and operability of the system's remote users.
+- **Operations terminal:** Workstation assigned to the system user which can be physically connected to the control sub-system or to a remote control centre.
+- **Multiplexor (MUX):** This element can be seen as a communication concentrator through which the whole management of OFPT communication with the different operation points of the system is undertaken. The connection between MUX and OFPT is usually point-to-point (PTP), using the basic telephony network when back-up lines are necessary, in cases where PTP communication is unavailable.
+
+
+
+Figure V.1/L.40 – OFMS architecture diagram. The diagram shows a central 'Operating network' (a cloud containing four blue nodes) connected to a 'LAN' at the top. Above the LAN are a 'Control Sub-system' (monitor icon), an 'Operations Terminal' (person at a computer), a 'Router', and a 'Remote control centre' (server icon). Below the central network, two identical monitoring branches are shown. Each branch consists of a 'LAN' connected to a 'MUX', which is connected to a 'Router'. This router is connected to a 'PTP' (Point-to-Point) node, which is connected to an 'RTC Back-up' (circular icon with an 'X'). The RTC Back-up is connected to three 'OFTP' (Optical Fibre Termination Point) modules. These modules are connected to a 'Remote selection Module'. Below the modules, two yellow cylinders represent 'Monitoring fibres', with red arrows indicating data flow between the OFTP modules and the fibres. The text 'T0605140-01' is in the bottom right corner.
+
+T0605140-01
+
+**Figure V.1/L.40 – OFMS architecture**
+
+- **OFTP:** Consists of three different modules (communication control, reflectometric measurements and local selection), controls the state of the assigned fibre, generating an alarm (which is communicated to the corresponding control centre) when the recorded measurement is outside the reference limits of the previously defined system.
+- **Remote selection module:** This module is connected by means of an optical fibre to the OFTP to allow monitoring of the fibre (or section of the fibre) when it is some distance from the OFTP.
+
+## V.6 Incorporation of the system in the centralized monitoring structure
+
+As explained in detail above, the optical fibre monitoring system is a plant management and control system which has to be incorporated in the centralized monitoring structure of the plant currently in operation.
+
+# **SERIES OF ITU-T RECOMMENDATIONS**
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series B | Means of expression: definitions, symbols, classification |
+| Series C | General telecommunication statistics |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | TMN and network maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks and open system communications |
+| Series Y | Global information infrastructure and Internet protocol aspects |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/20ab59bc10b900f6cf8a34549848bbf4_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/20ab59bc10b900f6cf8a34549848bbf4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b7e00510bfe65000b007dc347a32761e2786e208
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/20ab59bc10b900f6cf8a34549848bbf4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:326afcabc17ed873263a47c799d3e448b5229c829997b95600ce7f72f21815d4
+size 151727
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ab2cbdd4af6bc1ea9ffa8cca87f9d455eb147008
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:94ee226724314e8b36ac3c73e99f9ed2a4fbb4786e0c7f3f43c1debd5966aa00
+size 8239
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/562f471e8153729557e6a4ee6343c32c_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/562f471e8153729557e6a4ee6343c32c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2730e3b965d8fad664c8ca9058af7367957dff47
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/562f471e8153729557e6a4ee6343c32c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fcf080b050726b6857e66d0d02e5f207a081c71225bafdc056449ec42d161da2
+size 77552
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..81d1883850678b0dae735472b089b3f58580cacf
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:52bf3ed743aa3df4582e0ed776a7e5ac56d0b7d8f086cc905b2ce46bb69e7f5f
+size 17084
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..821693d7722972fc23a3721e692ef38a2248fb1c
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4aeed862a6e7a582daed0c4e1c4a8b31097520d9b82ef8936426a094636ed89c
+size 20302
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/967c30813761a8952ecc5e16bf42ea45_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/967c30813761a8952ecc5e16bf42ea45_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..34662023df27ba332b5b7690dbfe1321c37d0ae0
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/967c30813761a8952ecc5e16bf42ea45_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:48f13c8ffd394c27f367acade7070378513ce7cc03fcc226278c52f687ad4d44
+size 17374
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/b25cc68846b070bbe56a949b011ba91c_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/b25cc68846b070bbe56a949b011ba91c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c9d5538c218aafa5650367348ad5bd31272f6687
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/b25cc68846b070bbe56a949b011ba91c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f347e63c5be5de46fa552c87f2bf3e91c4f165fcffed2e8ef87254e37a916f8c
+size 20370
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d1e294c63d2d8c21395d8e2b161e5769e277c7e8
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bbec416f34c22bd45c5dd7c271677dfa259cd900ce37efa0229c49bff373472d
+size 67325
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/d3f6de4fe9f9138fc6afc584b5104433_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/d3f6de4fe9f9138fc6afc584b5104433_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f5bc9c0a1ad59c1fa0f5aafe7b696faacccda6a9
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/d3f6de4fe9f9138fc6afc584b5104433_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ce02a2e90f7b22438c23f71e2135fb51c4852228cc9a7ded113328122b972184
+size 36100
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/d5a837fa4f4675e5ee596003cf55985c_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/d5a837fa4f4675e5ee596003cf55985c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2430805efbb474a201cad93df30158c09b7cda78
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/d5a837fa4f4675e5ee596003cf55985c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d288b8e1c60778d6a9ce0ca23fe41dfe71aa0dcf6379494104cebc2c1252d4b3
+size 38017
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg b/marked/L/T-REC-L.46-200010-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..895bd4223d60998b03012ea059ff733e9edf3e51
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:854a2b477a9eb244d34ef7d7b17903670a15b3006d0965057103dd1efb21cc9c
+size 71226
diff --git a/marked/L/T-REC-L.46-200010-I_PDF-E/raw.md b/marked/L/T-REC-L.46-200010-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..d8c4b65d2b58fd2d385b2bd6f1102000ba8dec53
--- /dev/null
+++ b/marked/L/T-REC-L.46-200010-I_PDF-E/raw.md
@@ -0,0 +1,604 @@
+
+
+
+
+ITU logo: A globe with a lightning bolt and the letters ITU.
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.46**
+
+(10/2000)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Protection of telecommunication cables and
+plant from biological attack**
+
+ITU-T Recommendation L.46
+
+(Formerly CCITT Recommendation)
+
+---
+
+# **Protection of telecommunication cables and plant from biological attack**
+
+## **Summary**
+
+This Recommendation describes biological attacks and countermeasures for protection of telecommunication cables. It deals with the kinds of biological attack, weakness of cables, features of damage, and considers alternative ways of protecting the plant including dependence on cable position.
+
+## **Source**
+
+ITU-T Recommendation L.46 was prepared by ITU-T Study Group 6 (1997-2000) and approved by the World Telecommunication Standardization Assembly (Montreal, 27 September – 6 October 2000).
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database.
+
+© ITU 2001
+
+All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from ITU.
+
+## CONTENTS
+
+| | Page |
+|------------------------------------------------------------|------|
+| 1 Scope..... | 1 |
+| 2 The kinds of biological attacks ..... | 1 |
+| 3 Types of damage experienced..... | 1 |
+| 3.1 Mammals (e.g. squirrels, rats, mice and gophers) ..... | 1 |
+| 3.2 Insects ..... | 1 |
+| 3.2.1 Termites and ants..... | 1 |
+| 3.2.2 Beetles, larvae and other insects..... | 1 |
+| 3.3 Birds..... | 2 |
+| 3.4 Micro-organisms ..... | 2 |
+| 4 Type of protection..... | 2 |
+| 4.1 Positioning of plant in certain locations ..... | 2 |
+| 4.2 Elimination of the pest..... | 2 |
+| 4.3 Protection of telecom plant ..... | 3 |
+| 4.4 Cable construction ..... | 3 |
+| Appendix I..... | 4 |
+| Appendix II ..... | 5 |
+
+# **Protection of telecommunication cables and plant from biological attack**
+
+## **1 Scope**
+
+There is evidence that the outside of the plant can be damaged from biological attack. Some attacks are localized to particular environments which nurture certain types of infestation. Sometimes movement of the plant away from these areas is enough to avoid damage. More typically, the plant is shielded against attack by preventing penetration of pests some of which are listed in clause 2.
+
+## **2 The kinds of biological attacks**
+
+It is known that cable damage may be caused by:
+
+- mammals, squirrels, mice, rats, moles, gophers and other rodents;
+- birds like woodpeckers and cockatoos;
+- insects such as termites, ants, beetles, wasps and caterpillars;
+- micro-organisms like bacteria, fungus and/or moulds.
+
+## **3 Types of damage experienced**
+
+From an investigation of the damage sustained it is possible to determine the type of pest involved. Typical features of damage are given below.
+
+### **3.1 Mammals (e.g. squirrels, rats, mice and gophers)**
+
+Vertical chiselling of incisors on the edge of irregular holes is typical of the damage caused by rodents.
+
+Spherical or cylindrical holes with smooth walls are characteristic for the attack of moles. The animals are often found in the hole.
+
+### **3.2 Insects**
+
+#### **3.2.1 Termites and ants**
+
+Irregular holes that may extend over the whole circumference, looking as though the sheath has been peeled off, are typical of termites and ants.
+
+A mat appearance, to a surface that has been chewed over, is typical of termite gnawing, because they dig and lever upward with their short squat mandibles. Scratch marks and a transverse assault on the cable are characteristic of the ant, which has long, sharp mandibles and adopts a cutting action. In the early stages, the attack is characterized by local gatherings of numerous, small, individual holes.
+
+Ants and termites can give off an acidic secretion that is corrosive to lead.
+
+#### **3.2.2 Beetles, larvae and other insects**
+
+Horizontal traces of mandibles of different shapes on the edges of the holes, are indications of attacks by insects and larvae. Circular bores are typical of larvae and beetles. Depending on the angle at which they penetrate the sheath, they may look circular or elongated with a width equal to the diameter of the bore.
+
+### 3.3 Birds
+
+Irregular nibbles by beaks on the edge of and around irregular holes, are signs of attacks by birds.
+
+NOTE – Earwigs, spiders, pupas and other animals, often invade junction boxes and other open spaces. If the ventilation holes are big enough, even bird-nests, squirrel-nests and mice-nests can be found in the boxes. The debris these animals (in 3.1 to 3.3) produce from their excrements, also contribute to the breakdown of the insulation of connectors and terminal blocks.
+
+### 3.4 Micro-organisms
+
+Deterioration of the mechanical properties of cellulose fibres and elasticized polymers, is characteristic of attacks by fungi and bacteria. These attacks depend on the material and its manufacturing process.
+
+Local aeration corrosion cells can be produced by the attachment of barnacles, which are tight enough to exclude oxygen. These cells can be the result of bacterial metabolism in a polluted environment.
+
+## 4 Type of protection
+
+### 4.1 Positioning of plant in certain locations
+
+Attacks on telecom plants may be confined to certain areas where the conditions allow the pests to thrive. If it is possible to re-route the plant away from these areas, instances of attack and plant damage can be avoided.
+
+Examples of particular environments and the type of biological attacker found in them are shown in Table 1.
+
+**Table 1/L.46 – Typical environment for pests**
+
+| Environment | Pest |
+|------------------------------------------------------------------------------------------------|----------------------|
+| Breeding places in rubber estates | Insects |
+| Willow, cascara, scrub oak areas and old trees | Olive beetles |
+| Telecom plant in contact with plants (vegetable) – cable drums- poles-wood debris-bamboo-roots | Insects and larvae |
+| Dry rotting tree roots and wood debris | Termites |
+| Above ground Up to 1.5 m in hard soil Deeper in soft soil | Ants |
+| Polluted soil and water creating anaerobic conditions | Bacterial metabolism |
+| Overhead | Squirrels and birds |
+
+### 4.2 Elimination of the pest
+
+Where it is not possible to re-site the plant one possible action could be to eliminate the pests such as insects and rodents using chemicals or poisons.
+
+It should be noted that some chemicals and poisons are useful as a countermeasure for biological attacks, but they sometimes can also be a danger to humans and cause environmental pollution. Therefore, very careful handling is required when using any chemical method to prevent biological attacks. Also, materials' safety data and other specifications should be referred to before they are
+
+used. Poisons and chemicals should be stored safely in accordance with the supplier's recommendations.
+
+Some chemicals are useful as a deterrent. These chemicals do not work as poisons but they repel the attacker. For example, some chemicals are sprayed on the cable surface and leave a special smell as a deterrent.
+
+### 4.3 Protection of telecom plant
+
+Another option for protection of the plant is to shield it by the use of protective materials around the plant in order to prevent access. Examples of the way to prevent access of the pests are given in Table 2.
+
+**Table 2/L.46 – External measures for protection against pests**
+
+| Action | Pest |
+|--------------------------------------------------------------------------------------------|------------------------------|
+| Application of screens over ventilation opening | Squirrels, rodents and birds |
+| Steel net over cable | Squirrels |
+| Tightening of fittings in junction boxes, blocking with epoxy resin casting in small boxes | Ants, insects and beetles |
+| Compact into hard soil around cables and joints | Ants and insects |
+| Cables in small diameter duct to prevent entry | Rats and mice |
+| Galvanized iron guards around the cables as they emerge from the ground | Rodents, ants and insects |
+| Chemical repellents sprayed on telecom plant or spread around it | Insects, spiders and wasps |
+| Covering/repair of damaged duct | Rats |
+
+### 4.4 Cable construction
+
+Cables with sheaths of lead, polyethylene, polyvinylchloride, neoprene and other polymers are all susceptible to attacks. Examples of cable constructions that offer protections are given in Table 3.
+
+**Table 3/L.46 – Cable construction for protection against pests**
+
+| Protection | Pest |
+|------------------------------------------------------------------|-----------------------------------------------------|
+| Steel wire, fibreglass or aramid armouring | Squirrels and rodents |
+| Steel sheath or steel tape laminate | Birds |
+| Polyamide sheath | Ants and termites |
+| Helical steel or brass tape | Birds (woodpeckers) and termites |
+| Helical steel (0.2 mm) lapping with bituminous compound flooding | Contact with plants induce beetle and larvae attack |
+
+Aluminium tape offers limited protection, especially thin foil (e.g. 0.1 mm) that is easy to penetrate. Therefore, the thickness of aluminium tape should be considered carefully.
+
+Cables with steel armouring and/or dielectrical armouring such as fibreglass do not suffer any damage of this type as long as the armour is intact. Discontinuity in the armor leads to damage from beetles and larvae. Openings in the steel armour may have their origin in imperfect splicing and careless repairs, wrinkles and mechanical damage or by corrosion.
+
+Coatings of hessian, jute yarn or paper fibres impregnated with tar or bituminous compounds, give no protection.
+
+## APPENDIX I
+
+Table I.1 shows the main biological attackers and countermeasures.
+
+**Table I.1/L.46 – The main biological attackers and countermeasures**
+
+| Caused by | Attackers | Position | Troubles | Countermeasures |
+|----------------------------------|----------------------------|----------------------------------------------------|------------------------------|----------------------------------------------------------------------------------|
+| Mammals | Rats and Mice | Underground cables Duct cables Indoor cables | Bite, Food, Cut | Armouring net OLMA Sealing of duct Chemicals |
+| Mammals | Moles | Underground cables | Cut | Armouring net OLMA |
+| Mammals | Squirrels | Aerial | Bite, Cut | OLMA |
+| Birds | Woodpeckers Other Birds | Aerial | Peck, Make hole Make nest | Steel tape OLMA |
+| Insects | Ants and Termites | Underground Aerial | Bite Bite | Polyamide jacket Steel tape and Brass tape Air tightness of closures |
+| Insects | Cicada | Aerial | Lay Eggs, Make hole | Steel tape |
+| Micro organism | Bacteria | ----- | ----- | ----- |
+| OLMA Over Lay Metallic Armouring | | | | |
+
+## APPENDIX II
+
+Experience for biological attacks is shown in this Appendix from Table II.1 to II.7. The information is gathered from Argentina, Italy, Japan, Spain, Ukraine and Brazil. The places of attacks are shown in Figure II.1.
+
+
+
+T0604880-00
+
+A Transmission Facilities, ex. FTM, DSU
+ B Cables installed in tunnels, Metallic/Optical
+ C Underground Closure
+ D Duct Cables
+ E Underground (Direct buried) Cables
+ F Aerial Closures
+ G Aerial Cables, Metallic/Optical
+ H Dropping Cables
+ I Terminal Box, ex. Arrestor Box
+ J Indoor Cables
+ K Equipment
+ a Telecom facilities
+ b Tunnel
+ c Ducts
+ d Manhole
+ f Pole
+
+Diagram illustrating various locations of biological attacks on telecommunications infrastructure. The diagram shows a cross-section of the ground with underground and aerial components. Labels include: 'a' (Telecom facilities), 'A' (Transmission Facilities), 'B' (Cables in tunnels), 'C' (Underground Closure), 'D' (Duct Cables), 'E' (Direct buried cables), 'F' (Aerial Closures), 'f' (Pole), 'G' (Aerial Cables), 'H' (Dropping Cables), 'I' (Terminal Box), 'J' (Indoor Cables), 'K' (Equipment), 'b' (Tunnel), 'c' (Ducts), and 'd' (Manhole). A building on the right contains equipment 'K' and indoor cables 'J'. A reference code 'T0604880-00' is present.
+
+**Figure II.1/L.46 – Illustration for places attacked by plants and animals**
+
+**Table II.1/L.46 – Argentine experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|-----------|---------------|--------------------|---------------|-----------------|
+| B | All season | Mammals | Rats | Bite | – | None |
+| G | All season | Bacteria | Others | Peck | – | None |
+| F | All season | Bacteria | Others | Make Nest | – | None |
+
+**Table II.2/L.46 – Italian experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|-----------|---------------|--------------------|---------------|-----------------|
+| D | All season | Mammals | Rats | Bite | 1993 to 1995 | None |
+
+**Table II.3/L.46 – Indonesian experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|-----------|---------------|-------------------------------------|---------------|-------------------------------------|
+| Jakarta | All season | Mammals | Rats | Bite, cut | 1998 | Making sealing of the cable's ducts |
+| Jakarta | All season | Insect | Ants | Bite, make nest | 1997 | Chemicals, inserting wax |
+| Ujung Pandang | All season | Insect | Ants | Bite, short circuit | 1997 | None |
+| Many places | All season | Mammals | Mice | Bite, cut, short circuit, make nest | 1996-1998 | None |
+| Ambon | All season | Birds | Cockatoos | Bite | 1997-1998 | None |
+
+**Table II.4/L.46 – Japanese experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|------------------|-------------------------------------|------------------------------|---------------|-----------------------------------------------------------------------------------|
+| G | All season | Mammals, insects | Rats, squirrels, mice, caterpillars | Bite (Figures II.2 and II.3) | 1996-1999 | OLMA (Steel outer layer) (Figure II.4) Replacement with HS cable (Figure II.5) |
+| F | Autumn | insects | Ants | Bite | 1998 | Improvement of airtightness |
+| H | Summer | insects | Cicada | Lay eggs | 1998 | OLMA (Steel outer layer) Replacement with HS metallic wire |
+
+
+
+A photograph showing a close-up of a cable or wire that has been severely damaged by rats, with visible gnawing and exposed internal components.
+
+T0604890-00
+
+**Figure II.2/L.46 – Example of trouble by rats**
+
+
+
+A photograph of a cable with a circular patch on its surface, showing damage caused by caterpillars.
+
+T0604900-00
+
+**Figure II.3/L.46 – Example of trouble by caterpillars**
+
+Polyvinyl Chloride (PVC) Sheet
+
+
+
+A cross-sectional diagram of a cable. The outer layer is labeled 'Polyvinyl Chloride (PVC) Sheet' and the inner core is labeled 'Stainless Steel'.
+
+Stainless Steel
+
+**a) Configuration**
+
+
+
+A longitudinal diagram of a cable showing sections of 'Aerial Cable' and 'PVC Tape' wrapped around it. The PVC tape is shown as overlapping cylindrical segments.
+
+Aerial Cable
+
+PVC Tape
+
+T0604910-00
+
+**b) Illustration of how to use OLMA**
+
+**Figure II.4/L.46 – OLMA**
+
+
+
+Diagram of a high strength (HS) cable configuration. The diagram shows a cross-section of the cable with several layers. At the center is a 'Central strength element (Central rod)'. Surrounding this are 'Optical fibre ribbons'. The next layer is 'Stainless steel', represented by multiple concentric circles. The outermost layer is the 'PE outer sheath (PE = Polythene)'. A label 'T0604920-00' is at the bottom right of the diagram.
+
+**Figure II.5/L.46 – Configuration of high strength (HS) cable**
+
+**Table II.5/L.46 – Spanish experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|-----------|---------------|--------------------|---------------|-----------------|
+| D | All season | Mammals | Rats | Cut | 1996 | None |
+| M | All season | Mammals | Rats | Cut | 1996 | None |
+| M | All season | Mammals | Rats | Cut | 1997 | None |
+| M | All season | Mammals | Rats | Cut | 1997 | Sealing |
+
+**Table II.6/L.46 – Ukrainian experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------|-----------|---------------|--------------------|---------------|--------------------------|
+| J (3 events) | All season | Mammals | Rats | Bite | 1998 | Over lay metallic fray |
+| J (3 events) | All season | Mammals | Rats | Food, Bite | 1998 | OLMA |
+| D, J | All season | Mammals | Rats | Bite, Cut, Scratch | 1998 | Armouring Net, chemicals |
+| D | All season | Mammals | Rats | Bite | 1996 | Over lay |
+| D (20 event) | All season | Mammals | Rats | Bite | 1997 | Over lay |
+| D | All season | Mammals | Rats | Bite | 1998 | Making sealing of duct |
+| D (2 event) | All season | Mammals | Rats | Cut, Food, Bite | 1998 | Over lay |
+| D | All season | Mammals | Rats | Food | 1998 | OLMA |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|---------------------------|------------------|-----------|------------------|---------------------------------------|------------------|-------------------------------------|
+| D (manhole) | All season | Mammals | Rats | Bite | 1998 | OLMA |
+| E | All season | Mammals | Rats | Scratch (gnawed sheath) | 1997 | Armouring Net |
+| E (2 event) | All season | Mammals | Rats | Food (gnawed sheath) | 1998 | |
+| D | Spring Summer | Mammals | Rats | Bite (gnawed sheath) | 1998 | |
+| D (10 event) | Spring Summer | Mammals | Rats | Food (gnawed sheath) | 1998 | Chemicals |
+| D (manhole 4 event) | Spring Summer | Mammals | Rats | Food (gnawed sheath) | 1998 | Chemicals |
+| D (manhole) | Summer Autumn | Mammals | Rats | Bite (gnawed sheath) | 1998 | |
+| J | Spring | Mammals | Rats | Bite | 1997 | |
+| J (4 event) | Spring | Mammals | Rats | Bite | 1998 | |
+| J | Spring | Mammals | Rats | Bite | 1998 | Over lay |
+| J | Spring | Mammals | Rats | Bite | 1998 | Chemicals |
+| D (2 event) | Spring | Mammals | Rats | Bite (FO damaged) | 1996 | |
+| D (2 event) | Spring | Mammals | Rats | Bite | 1998 | Chemicals |
+| D (2 event) | Spring | Mammals | Rats | Food, Bite | 1998 | Over lay |
+| D (7 event) | Spring | Mammals | Rats | Bite | 1998 | |
+| D (manhole 4 event) | Spring | Mammals | Rats | Bite | 1996 | Chemicals |
+| D (manhole) | Spring | Mammals | Rats | Bite (damaged cables; 10 mm) | 1998 | Making embedding cable with OLMA |
+| B | Spring | Mammals | Rats | Bite | 1998 | Armouring Net |
+| E (2 event) | Spring | Mammals | Rats | Food | 1998 | OLMA |
+| E | Spring | Mammals | Rats | Bite | 1998 | Armouring Net |
+| E | Spring | Mammals | Rats | Bite | 1998 | Chemicals |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|--------------------------|--------|-----------|------------------|-------------------------------|------------------|-----------------|
+| J (3 event) | Summer | Mammals | Rats | Bite | 1998 | Over lay |
+| D | Summer | Mammals | Rats | Bite (FO damaged) | 1996 | |
+| D | Summer | Mammals | Rats | Bite (Damaged cables; 3 m) | 1996 | Over lay |
+| D | Summer | Mammals | Rats | Food (consumed leaden sheath) | 1996 | Over lay |
+| D (2 event) | Summer | Mammals | Rats | Bite (damaged cable; 0.5-3 m) | 1997 | Over lay |
+| D | Summer | Mammals | Rats | Food | 1998 | Over lay |
+| D | Summer | Mammals | Rats | Food | 1998 | Over lay |
+| D (4 events) | Summer | Mammals | Rats | Bite | 1998 | |
+| D (manhole 4 events) | Summer | Mammals | Rats | Bite | 1998 | Chemicals |
+| D (manhole 20 events) | Summer | Mammals | Rats | Bite | 1998 | |
+| E | Summer | Mammals | Rats | Food | 1998 | OLMA |
+| E | Summer | Mammals | Rats | Bite | 1998 | Armouring Net |
+| E | Summer | Mammals | Rats | Cut | 1998 | |
+| E | Summer | Mammals | Rats | Bite | 1998 | Chemicals |
+| D | Autumn | Mammals | Rats | Bite (FO damaged) | 1998 | |
+| D | Autumn | Mammals | Rats | Food | 1998 | Over lay |
+| D | Autumn | Mammals | Rats | Bite | 1998 | Chemicals |
+| D (50 events) | Autumn | Mammals | Rats | Cut | 1998 | |
+| D (20 events) | Autumn | Mammals | Rats | Cut | 1998 | Chemicals |
+| D (8 events) | Autumn | Mammals | Rats | Scratch, Food, Bite | 1998 | Over lay |
+| D (manhole) | Autumn | Mammals | Rats | Bite (FO damaged) | 1997 | |
+| D (manhole) | Autumn | Mammals | Rats | Bite | 1998 | |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|----------------------------|--------------------|-----------|------------------|--------------------------------------------------------------|------------------|-----------------------------|
+| D (manhole 4 events) | Autumn | Mammals | Rats | Bite | 1998 | Chemicals |
+| E (2 events) | Autumn | Mammals | Rats | Cut | 1998 | Chemicals |
+| J | Winter | Mammals | Rats | Bite | 1998 | Chemicals |
+| J | Winter | Mammals | Rats | Cut | 1998 | |
+| D | Winter | Mammals | Rats | Cut | 1997 | OLMA |
+| D (2 events) | Winter | Mammals | Rats | Bite | 1998 | |
+| D | Winter | Mammals | Rats | Bite | 1998 | Over lay |
+| D (manhole) | Winter | Mammals | Rats | Bite | 1998 | |
+| D | Autumn | Mammals | Mice | Bite, Cut, Scratch (gnawed sheath: 40×100 mm) | 1998 | Armouring Net, chemicals |
+| E | Autumn | Mammals | Mice | Scratch (gnawed sheath) | 1996 | |
+| E | Spring – Autumn | Mammals | Mice | Bite, Food, Nest (D=0.5-10 mm) | 1997 1998 | Chemicals |
+| E | Spring Summer | Mammals | Mice | Cut, Food | 1998 | |
+| D | Spring Summer | Mammals | Mice | Bite (gnawed sheath) | 1998 | |
+| E (2 events) | Spring | Mammals | Mice | Food, Cut, Make Nest, Scratch | 1998 | OLMA |
+| E | Spring | Mammals | Mice | Bite (circle d=10 mm) | 1997 | OLMA |
+| E | Spring | Mammals | Mice | Food (damaged cables) | 1998 | |
+| D (2 events) | Spring | Mammals | Mice | Cut, Food (damaged cables) | 1998 | |
+| D (2 events) | Spring | Mammals | Mice | Others | 1998 | Over lay |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|--------|-----------|---------------|---------------------------------------------|--------------------|-----------------|
+| E | Summer | Mammals | Mice | Bite (damaged cables: 4 m, 2 m) | 1997 | Over lay |
+| E | Summer | Mammals | Mice | Make Holes | 1997-1998 | Chemicals |
+| E (2 events) | Summer | Mammals | Mice | Bite | 1998 | Armouring Net |
+| E (2 events) | Summer | Mammals | Mice | Cut, Make Nest, Scratch | 1998 | OLMA |
+| E | Summer | Mammals | Mice | Food | 1998 | |
+| E (2 events) | Summer | Mammals | Mice | Cut, Bite (damaged cables) | 1998 | |
+| E | Summer | Mammals | Mice | Food (damaged cables) | 1998 | |
+| D | Summer | Mammals | Mice | Food (damaged cables) | 1998 | |
+| D (2 events) | Summer | Mammals | Mice | Cut, Food (damaged cables) | 1998 | |
+| D | Summer | Mammals | Mice | Food (damaged cables) | 1998 | |
+| D (manhole) | Summer | Mammals | Mice | Others | 1998 | Chemicals |
+| E (events) | Autumn | Mammals | Mice | Bite (damaged cables: 2~6 m, 10 m) | 1991-1992, 1996 | Over lay |
+| E | Autumn | Mammals | Mice | Others | 1997 | Over lay |
+| E (events) | Autumn | Mammals | Mice | Cut, Food (damaged cables) | 1998 | |
+| E | Autumn | Mammals | Mice | Food | 1998 | OLMA |
+| D | Autumn | Mammals | Mice | Others | 1997 | Over lay |
+| D | Autumn | Mammals | Mice | Food (damaged cables) | 1998 | |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|----------------------------|-----------|---------------------|-------------------------------------------------------------|---------------|----------------------------|
+| J (2 events) | Autumn | Mammals | Rats, Mice | Bite, Make Nest (gnawed sheath: 2 m~10 m) | 1997-1998 | Chemicals Armouring Net |
+| D (2 events) | Autumn | Mammals | Rats, Mice | Bite, Make Nest (gnawed sheath: 2 m~10 m) | 1997-1998 | Chemicals Armouring Net |
+| B (2 events) | Autumn Summer | Mammals | Rats, Mice | Cut, Bite | 1998 | Over lay |
+| E (12 events) | Winter | Mammals | Rats, Mice | Cut, Bite | 1998 | Over lay |
+| D (manhole) | Autumn | Mammals | Rats, Mice | Bite, Cut (L=30 mm) | 1998 | Over lay |
+| E (37 events) | Autumn | Mammals | Rats, Mice | Bite (gnawed sheath: up to 1 m) | 1998 | |
+| E | Spring Summer Autumn | Mammals | Rats, Moles | Bite, Food, Make Nest, Cut (gnawed sheath: 10 mm~3 m) | 1997-1998 | Chemicals Armouring Net |
+| D (39 events) | Autumn | Mammals | Rats, Mice, Gophers | Cut, Bite, Food, Scratch | 1997-1998 | Over lay Chemicals |
+| E | Autumn | Mammals | Gophers | Food | 1998 | OLMA Chemicals |
+| E (3 events) | Spring | Mammals | Gophers | Bite (damaged cables: 15 m, 10 m) | 1998 | Over lay |
+| E | Spring | Mammals | Gophers | Bite | 1998 | Armouring Net |
+| E | Spring | Mammals | Gophers | Cut | 1997 | |
+| E | Summer | Mammals | Gophers | Bite (damaged cables: 2 m) | 1996 | Over lay |
+| E | Summer | Mammals | Gophers | Bite (damaged cables: 2 m) | 1997 | Over lay |
+| E | Summer | Mammals | Gophers | Cut | 1998 | Armouring Net |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|--------|-----------|------------------|---------------------------------------------------------------|------------------|-------------------|
+| E | Summer | Mammals | Gophers | Food | 1996 | OLMA Chemicals |
+| E (3 events) | Autumn | Mammals | Gophers | Bite, Make Nest (damaged cables: 0.1 m, 0.5 m) | 1997 | Over lay |
+| E (3 events) | Autumn | Mammals | Gophers | Bite (damaged cables: 0.2 m, 0.5 m) | 1995 1997 | Over lay |
+| E (2 events) | Autumn | Mammals | Gophers | Cut | 1998 | Armouring Net |
+| E (2 events) | Autumn | Mammals | Gophers | Food | 1995 1997 | OLMA Chemicals |
+| E | Autumn | Mammals | Gophers | Cut, Make Nest, Scratch | 1998 | OLMA |
+| E | Winter | Mammals | Gophers | Bite (damaged cables: 50 mm) | 1998 | Over lay |
+| E (6 events) | Winter | Mammals | Gophers | Bite (damaged cables: 0.15~0.3 m, 20 m) | 1996 1998 | Over lay |
+| E | Winter | Mammals | Gophers | Cut, Make Nest, Scratch | 1998 | OLMA |
+| E (4 events) | Spring | Mammals | Moles | Cut, Food (damaged cables) | 1998 | |
+| E (2 events) | Summer | Mammals | Moles | Bite (gnawed sheath), Food (damaged cables) | 1998 | |
+| E | Summer | Mammals | Moles | Make Holes | 1998 | Armouring Net |
+| E | Autumn | Mammals | Moles | Bite (gnawed sheath) | 1998 | |
+| E | Autumn | Mammals | Moles | Food | 1998 | OLMA |
+
+**Table II.6/L.46 – Ukrainian experience (continued)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|------------------|-----------|--------------------------|-------------------------------------------|------------------|-----------------|
+| E | Summer | Mammals | Hamsters | Food (gnawed sheath) | 1998 | OLMA |
+| E (13 events) | Spring Autumn | Mammals | Hamsters | Bite | 1998 | |
+| E (3 events) | Winter | Mammals | Hamsters | Bite (hole d:20 mm) | 1996- 1998 | OLMA |
+| E | Summer | Mammals | Hamsters | Bite | 1998 | Armouring Net |
+| E (2 events) | Autumn | Mammals | Hamsters | Bite | 1998 | Armouring Net |
+| E (2 events) | Summer | Mammals | Beavers | Cut | 1995- 1996 | Armouring Net |
+| E (3 events) | Autumn | Mammals | Beavers | Cut | 1998 | Armouring Net |
+| E | Summer | Mammals | Ondatra | Bite (damaged cables: 0.3 m) | 1995 | Over lay |
+| D (manhole) | Winter | Mammals | Dogs | Bite (FO damaged) | 1994 | |
+| G (4 events) | Summer | Birds | Woodpeckers | Peck (peck and holes in poles) | 1998 | |
+| F (2 events) | Spring | Birds | Woodpeckers | Peck (holes d=25 mm, 30 mm) | 1998 | |
+| F (10 events) | Autumn | Birds | Woodpeckers | Peck (nest) | 1998 | |
+| F (8 events) | Spring Summer | Birds | Storks | Make Nest | 1998 | Over lay |
+| F (3 events) | Autumn Summer | Insects | Beetles (barkbeetles) | Lay Eggs Food | 1997- 1998 | Over lay |
+| H (2 events) | Autumn | Insects | Wasps | Cut, Make Nest | 1998 | Over lay |
+| I | Summer Autumn | Insects | Wasps | Make Nest | 1998 | Over lay |
+| E | Spring | Insects | Ants | Lay eggs, Degradation of insulation | 1998 | Over lay |
+| D | Autumn | Bacteria | Unknown | Culture media | 1998 | |
+| E | Autumn | Bacteria | Unknown | Culture media | 1998 | |
+
+**Table II.6/L.46 – Ukrainian experience (concluded)**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|------------------------|--------|-----------|---------------|--------------------|---------------|-----------------|
+| D | Autumn | Bacteria | Unknown | Culture media | 1998 | |
+| D | Spring | Fungus | Fungus | Corrosion | 1998 | Chemicals |
+| E | Summer | Plants | Unknown | Cut | 1998 | |
+
+**Table II.7/L.46 – Brazilian experience**
+
+| Place (Figure II.1) | Season | Caused by | Kind of cause | Example of trouble | When occurred | Countermeasures |
+|--------------------------------|------------|-----------|---------------|--------------------------------|---------------|---------------------------------------|
+| B (Buried Optical Cable) | All season | Mammals | Rodents | Bite, Make Holes | 1994 | OLMA, dielectric armour |
+| B (Induct Optical cable) | All season | Mammals | Rats | Bite, Make Holes, Scratch, Cut | 1996 | OLMA (Figure II.6) |
+| F (Aerial Closure-metallic) | All season | Insects | Ants | Make Pressure, Corrosion | 1994 | – |
+| E (Metallic Cable) | All season | Insects | Termites | Make Holes | 1982 | OLMA (Figure II.7) |
+| G (Aerial Optical Cable) | All season | Birds | Others | Bite, Make Holes | 1993 | – |
+| B (Buried Optical Cable) | All season | Mammals | Rodents | Bite, Make Holes, Scratch | 1995 | OLMA, dielectric armour (Figure II.8) |
+| G (Aerial Optical Cable) | All season | Mammals | Rodents | Bite, Make Holes | 1999 | (Figure II.9) |
+
+OLMA Over Lay Metallic Armouring
+
+
+
+A close-up photograph of a black optical cable. The cable is positioned horizontally against a light grey background. There are two distinct, oval-shaped indentations or marks on the top surface of the cable, spaced apart from each other. These marks appear slightly lighter in color than the surrounding cable material.
+
+A close-up photograph of a black optical cable with two small, oval-shaped indentations or marks on its surface.
+
+T0604930-00
+
+**Figure II.6/L.46 – Induct optical cable**
+
+
+
+A photograph of a metallic cable lying horizontally across a dry, reddish-brown earth surface. The ground is heavily cracked and covered with a dense network of dry, tangled roots. The cable itself appears to be made of metal, with a slightly reflective surface. There are visible signs of damage or wear along the length of the cable, particularly where it intersects with the roots.
+
+A photograph of a metallic cable lying on a dry, cracked, and root-covered ground surface, showing signs of damage.
+
+T0604940-00
+
+**Figure II.7/L.46 – Metallic cable damaged by insect**
+
+
+
+A photograph of a buried cable with a large section of its outer insulation missing, revealing internal components. A white circular marker with the number '1' is placed next to the cable for scale.
+
+A photograph of a buried cable with a large section of its outer insulation missing, revealing internal components. A white circular marker with the number '1' is placed next to the cable for scale.
+
+T0604950-00
+
+**Figure II.8/L.46 – Buried cable**
+
+
+
+A photograph of an aerial cable with several small sections of its outer insulation missing, revealing internal components.
+
+A photograph of an aerial cable with several small sections of its outer insulation missing, revealing internal components.
+
+T0604960-00
+
+**Figure II.9/L.46 – Aerial cable**
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series B | Means of expression: definitions, symbols, classification |
+| Series C | General telecommunication statistics |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | TMN and network maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks and open system communications |
+| Series Y | Global information infrastructure and Internet protocol aspects |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.47-200010-I_PDF-E/raw.md b/marked/L/T-REC-L.47-200010-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..f049a3202325dc5d79fd410bb4dfb3f3bc8f5920
--- /dev/null
+++ b/marked/L/T-REC-L.47-200010-I_PDF-E/raw.md
@@ -0,0 +1,1049 @@
+
+
+
+
+The logo of the International Telecommunication Union (ITU) features a globe with a lightning bolt superimposed on it, and the letters 'ITU' written across the center.
+
+ITU logo
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.47**
+
+(10/2000)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Access facilities using hybrid fibre/copper
+networks**
+
+ITU-T Recommendation L.47
+
+(Formerly CCITT Recommendation)
+
+---
+
+# **Access facilities using hybrid fibre/copper networks**
+
+## **Summary**
+
+This Recommendation gives information and guidelines about access facilities using HFC ("Hybrid Fibre/Copper") networks.
+
+HFC networks are necessary for the future introduction of multimedia services with several broadband applications. HFC networks offer more chances of use as only pure networks for telecommunication or for CATV (Cable Television) distribution. Additional services as Pay-TV, Pay-per-View, Video-on Demand, home-banking, -working, -shopping and Internet access can be offered by means of these networks.
+
+HFC networks represent also a step in the evolution process to GII (Global Information Infrastructure), that means a connection between CATV, telecommunications, data and mobile networks.
+
+Appendix II provides examples of HFC networks.
+
+## **Source**
+
+ITU-T Recommendation L.47 was prepared by ITU-T Study Group 6 (1997-2000) and approved by the World Telecommunication Standardization Assembly (Montreal, 27 September – 6 October 2000).
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database.
+
+© ITU 2001
+
+All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from ITU.
+
+## CONTENTS
+
+| | | Page |
+|-------|--------------------------------------------------------------------------------------------------------------------|-------------|
+| 1 | Scope..... | 1 |
+| 2 | Fundamental types of hybrid fibre/copper networks..... | 1 |
+| 3 | Physical elements of hybrid fibre/copper networks..... | 2 |
+| 3.1 | Optical elements ..... | 2 |
+| 3.1.1 | Optical cables ..... | 2 |
+| 3.1.2 | Optical connectors ..... | 2 |
+| 3.1.3 | Optical amplifiers ..... | 2 |
+| 3.1.4 | Optical splitters..... | 2 |
+| 3.2 | Electrical and copper elements ..... | 2 |
+| 3.2.1 | HFC-S networks ..... | 2 |
+| 3.2.2 | HFC-C networks..... | 3 |
+| 4 | Installation..... | 4 |
+| 4.1 | HFC-S networks ..... | 4 |
+| 4.2 | HFC-C networks ..... | 4 |
+| 4.2.1 | Coaxial cables..... | 4 |
+| 4.2.2 | Cabinets ..... | 4 |
+| 4.2.3 | Indoor installation..... | 5 |
+| | Appendix I – Questionnaire on Question 13/6 Access facilities using hybrid fibre/copper networks..... | 5 |
+| I.1 | Introduction..... | 5 |
+| I.2 | Topology ..... | 5 |
+| I.3 | Cable construction ..... | 6 |
+| I.4 | Components for CATV networks ..... | 6 |
+| I.5 | Cable installation ..... | 7 |
+| I.6 | Cabinet installation ..... | 7 |
+| | Appendix II – Italian experience on HFC-C networks ..... | 8 |
+| II.1 | Introduction..... | 8 |
+| II.2 | The HFC-C project ..... | 8 |
+| II.3 | Network infrastructure for Italy ..... | 10 |
+| II.4 | Coaxial network design ..... | 13 |
+| II.5 | Evolution towards all optical networks ..... | 14 |
+| | Appendix III – Indonesia's experience on HFC-C networks Access facilities using hybrid fibre/copper networks ..... | 15 |
+| III.1 | Introduction..... | 15 |
+| III.2 | Background ..... | 15 |
+
+| | Page |
+|---------------------------------------------------|-------------|
+| III.3 Network topology ..... | 15 |
+| III.3.1 Transport network topology..... | 15 |
+| III.3.2 Access network topology..... | 16 |
+| III.3.3 Coaxial network topology..... | 16 |
+| III.4 Cable construction ..... | 17 |
+| III.4.1 Optical cabling..... | 17 |
+| III.4.2 Coaxial cabling..... | 17 |
+| III.5 Bandwidth allocation ..... | 18 |
+| III.6 System configuration ..... | 18 |
+| III.6.1 Headend ..... | 19 |
+| III.6.2 Distribution hub..... | 19 |
+| III.6.3 Fibre node ..... | 20 |
+| III.6.4 Amplifier (active component)..... | 20 |
+| III.6.5 Passive component ..... | 20 |
+| III.7 Powering system ..... | 21 |
+| III.7.1 Powering system in coaxial cable..... | 21 |
+| III.8 Outside plant (OSP)..... | 21 |
+| III.8.1 Pole ..... | 21 |
+| III.8.2 Cabinet..... | 22 |
+| III.9 Standardization ..... | 22 |
+| III.10 Coaxial network planning tool..... | 22 |
+| III.11 Component for coaxial HFC-C networks ..... | 23 |
+| III.12 Legend..... | 23 |
+
+## **Access facilities using hybrid fibre/copper networks**
+
+# **1 Scope**
+
+This Recommendation:
+
+- gives general information on the fundamental types of hybrid fibre/copper networks;
+- describes the most important physical elements of HFC networks apart from transmission equipment;
+- gives general information and guidelines for the installation of HFC networks.
+
+# **2 Fundamental types of hybrid fibre/copper networks**
+
+Very different HFC network topologies can be considered, according to different Administrations' and private operators' requirements, different country or regional situations, different provided multimedia services. Moreover, HFC networks can be based on already existing telephone networks, both for the fibre and for the copper part of the network. However, the following general considerations can be applied to all the HFC network types.
+
+An HFC network can be thought as composed of two main sections:
+
+- First section: the "Transport Network" where the services are generated and delivered (at a national, regional or local level) up to main distribution points. The extension of the Transport Network can be huge. The physical transmission medium is the optical fibre.
+- Second section: the "Access Network" where the final users are connected (at a local level) to the main distribution points. The extension of the Access Network is typically limited to a few kms in length. The bearer used in the first part of the Access Network is the optical fibre. The physical transmission medium of the last portion of the Access Network up to the users can be the symmetrical copper pair ("HFC-S" networks) or the coaxial copper/aluminium pair ("HFC-C" networks).
+
+Typically, HFC-S networks are directly derived from traditional telephone copper access networks. The evolution towards new services can be achieved by means of particular data compression (JPEG, MPEG for instance) and transmission (HDSL, ADSL, VDSL for instance) techniques on the existing symmetrical pair cables. It is worth noticing that HFC-S type identifies a wide set of very different network solutions, according to the level of the optical fibre penetration into the Access Network and to the network topology. So, for instance, HFC-S type ranges from a simple point-to-point ADSL copper link up to FTTB ("Fibre To The Building") point-to-multipoint PON architectures.
+
+The term HFC-C identifies a more restricted set of network solutions. HFC-C networks typically entail the installation of new active and passive coaxial components in the last portion of the Access Network, even if a simple update of an already existing HFC-C unidirectional network towards interactive services is considered. New HFC-C networks can offer up to 1 GHz bandwidth for CATV broadcast transmission and other broadband multimedia services.
+
+It should be taken into account that:
+
+- a study of economic factors, of already existing telecommunication networks, of present and future service requirements, of rules and regulations in each region should be carried out in order to decide between a HFC-S and a HFC-C type network;
+
+- already existing infrastructures and ad hoc technical solutions should be used wherever possible in order to limit the environmental impact of the new HFC network, especially for the HFC-C network type.
+
+# **3 Physical elements of hybrid fibre/copper networks**
+
+## **3.1 Optical elements**
+
+### **3.1.1 Optical cables**
+
+Both HFC-S and HFC-C networks make use of single-mode optical fibre cables in the Transport and in the Access Network.
+
+It should be taken into account that:
+
+- ITU-T G.652, G.653, G.654 or G.655 single-mode optical fibre should be used in the Transport Network. ITU-T G.652 or G.655 single-mode optical fibre are used in the Access Network;
+- suitable studies have to be carried out in order to dimension the proper Access Network optical cable capacity: from 100 up to 1000 optical fibre cable capacities have been reported.
+
+### **3.1.2 Optical connectors**
+
+Any standard (IEC) connector can be used in the Transport and in the Access Network.
+
+In the case of analogue CATV transmission, the return loss of optical connectors needs to be carefully considered in order to meet the system requirements.
+
+### **3.1.3 Optical amplifiers**
+
+Optical amplifiers are used both in the Transport and in the Access Network. The use of optical amplifiers as boosters can be associated with tree-type optical network topologies and with the use of optical splitters.
+
+### **3.1.4 Optical splitters**
+
+In HFC networks, optical splitters are typically used in tree-type optical network topologies together with optical amplifiers in order to expand the distribution area of a single optical transmitter. In HFC-S PON (Passive Optical Networks) architectures optical splitters are used as branching devices both in central offices and in the field. From 1:2 up to 1:32 splitting ratios have been reported.
+
+## **3.2 Electrical and copper elements**
+
+### **3.2.1 HFC-S networks**
+
+#### **3.2.1.1 Symmetrical pairs cables**
+
+From 0.4 mm to 0.64 mm wire diameter symmetrical pairs copper cables are typically used in the Access Network for 100 up to 1500 metres typical distances. From 10 up to 3000 symmetrical pairs cable capacities are used, according to different Access Network requirements.
+
+Studies and characterizations should be carried out on the already existing symmetrical pair copper cables in order to verify that they can support the chosen xDSL transmission technique. Refer also to the G.990-series Recommendations.
+
+### **3.2.2 HFC-C networks**
+
+#### **3.2.2.1 Coaxial cables**
+
+- *Coax-trunk cable*
+1 GHz bandwidth, 12.7 mm (1/2 inch) or 19.05 mm (3/4 inch) outer conductor diameter, 75 ohm impedance coax-trunk cables are used in HFC-C Access Networks from 100 up to 500 metres typical link length between the launch and the last amplifier.
+- *Coax-drop cable*
+1 GHz bandwidth, RG-11 and RG-6 standard types, 75 ohm impedance coax-drop cables are used in HFC-C Access Networks from 50 up to 150 metres typical link length between the last amplifier and the coaxial network termination.
+
+Wherever possible, cables should be chosen in order to limit the number of coaxial amplifiers. In spite of their low mechanical flexibility (which can constitute a problem during installation), 19.05 mm (3/4 inch) outer conductor diameter coax-trunk cables offer very good attenuation performance.
+
+#### **3.2.2.2 Coaxial connectors**
+
+The 15.825 mm (5/8 inch) and F type coaxial connectors are typically used for cable terminations. However, many different connector versions can be used according to the different coaxial cables versions, dimensions and applications.
+
+Careful choice of connectors should be made in order to prevent in-field problems due to environmental causes (such as temperature, humidity, vibrations, etc.). In most of the cases, coaxial connectors should be protected by means of a shrinkable plastic sheath.
+
+#### **3.2.2.3 Coaxial splitters**
+
+Coaxial splitters are typically used on the output ports of coaxial amplifiers (especially in front of launch amplifier) in order to subdivide the electrical signal on the different coax-trunk cables of the HFC-C network. 1:2, 1:3 and 1:4 splitting ratios are common.
+
+#### **3.2.2.4 Coaxial taps**
+
+Coaxial taps are typically used on the output ports of the last amplifiers or for in-building coaxial distribution networks. Many types and versions are available on the market; 2, 4, 8 and 16 output ports coaxial taps are common.
+
+#### **3.2.2.5 Electro/optical converter and coaxial amplifiers**
+
+Electro/optical converters, launch amplifiers, line extenders and last amplifiers are used in HFC-C network respectively in order to transform the optical signal into an electrical one, to launch the electrical signal on the coaxial network, to amplify the electrical signal in the case of very long coaxial links (typically more than 500 metres), to amplify and to distribute the electrical signal to the final users area. The active tree-type coaxial network originated by a single electro/optical converter is usually designed in order to serve from 100 up to 500 users, by means of from 3 to 9 last amplifiers.
+
+The use of line extenders should be limited to those cases of actual necessity.
+
+#### **3.2.2.6 Power supply**
+
+The coaxial portion of an HFC-C network is remotely powered from the electro/optical-launch amplifier cabinet by means of a properly dimensioned power supply (45-60 Vac, 10-15 A are typical values).
+
+The power supply should be designed in order to limit the environmental impact (noise) in urban installation.
+
+# **4 Installation**
+
+This clause gives general information and guidelines on some particular aspects of the installation of metallic cables forming a part of HFC-S and HFC-C networks. See L-series Recommendations for optical fibre cable installation practices.
+
+## **4.1 HFC-S networks**
+
+HFC-S type identifies a wide set of very different network solutions, according to the level of the optical fibre penetration into the Access Network and to the network topology. So, installation procedures can involve a simple ADSL modem installation up to the in-field layering of new optical cables and ONU (Optical Network Unit) cabinets in the Access Network, with a huge variety of situations and potential problems.
+
+It should be taken into account that:
+
+- existing infrastructures should be used wherever possible (ducts, manholes, etc.);
+- proper technical solutions should be studied in order to limit the environmental impact of new cabinets and new cable installation in terms of civil works, urban soil occupation, visual effect;
+- proper technical solutions should be studied in order to ensure the reliability and the maintenance of the HFC-S network from the viewpoint of hardware and software;
+- existing infrastructures should be studied as to how they could be reused in HFC-S networks.
+
+## **4.2 HFC-C networks**
+
+With respect to the HFC-S type, the HFC-C type identifies a more restricted set of network solutions. Some information and guidelines are given in the following on different HFC-C network elements.
+
+### **4.2.1 Coaxial cables**
+
+Coax-trunk cables are typically less flexible and more cumbersome than, for instance, optical cables. Due to these reasons, ad hoc manholes, ducts and installation procedures have to be used in order to avoid any cable damage.
+
+It should be taken into account that:
+
+- suitable pulling, handling and layering procedures should be observed in order to avoid cable kinks according to the cable recommended curvature radius;
+- for in-duct installation, suitable ducts and manholes should be used for trunk cables. From 36 up to 63 mm diameter ducts have been reported for a single trunk cable installation;
+- for aerial or wall installation suitable cable accessories (holders, steel wires, lashes, etc.) should be used to support and fix the cable.
+
+### **4.2.2 Cabinets**
+
+The high number of outside plant cabinets for active equipment is a typical characteristic of HFC-C networks.
+
+Suitable cabinet design should be carried out in order to ensure the operative range of active equipment according to their characteristics and to the environmental conditions (temperature, humidity, vibrations).
+
+Proper technical solutions should be studied in order to limit the environmental impact of cabinets in urban areas. Different cabinet versions for on-ground, underground and aerial installations should be studied in order to meet particular installation requirements.
+
+### **4.2.3 Indoor installation**
+
+It should be noted that the installation of equipment for HFC-C networks in the customer's property could present problems in terms of obtaining permission of the user.
+
+It should be taken into account that:
+
+- existing building infrastructure should be used wherever possible;
+- additional infrastructure for drop cable installation should be avoided wherever possible;
+- cables and accessories have to satisfy country and regional regulations on fire protection requirements.
+
+# **APPENDIX I**
+
+## **Questionnaire on Question 13/6 Access facilities using hybrid fibre/copper networks**
+
+## **I.1 Introduction**
+
+This appendix summarizes the main results of the Questionnaire on Access Facilities Using Hybrid Fibre/Copper Networks. Five countries (Italy, Japan, Spain, Sweden and United Kingdom) answered to the questionnaire. A comparative detailed report of the answers of each country is given in this appendix.
+
+## **I.2 Topology**
+
+**I.2.1** General description of the network: The network provider is a private operator; the network has a star configuration or a point-to-multipoint or ring. It is extended to regions or countries. Generally all the types of listed cables, and particularly copper cables in Japan and Sweden, are used.
+
+Hybrid technology is used.
+
+The transmission range frequency plan varies considerably. It is 54-862 MHz (downstream) and 5-40 MHz (upstream) in Italy, 50 Mbit/s bidirectional with TDMA in Japan, 86-862 MHz downstream and 5-55 MHz upstream in Spain. It is 54 (70,85)-860 MHz downstream and 5-25(50,60) MHz upstream in Sweden, 10-65 MHz upstream and 85-860 MHz downstream in the United Kingdom.
+
+The transmission is both analogic and digital. Generally the provided services are CATV and interactive services.
+
+**I.2.2** Transport network topology: The used topology is a star or ring configuration and the transmission technology is SDH. The transmission medium is optic fibres and the cable type is in-duct.
+
+**I.2.3** Access network: The topology is a star one or point-to-multipoint. The transmission medium is optic fibres and the cable type is an in-duct one.
+
+**I.2.4** Subscriber access: The topology is tree.
+
+The transmission media are copper pairs, coaxial cable and optical fibres. The cable type is in-duct and aerial. The number of consumers supplied between last amplifier and NT varies from 60-70 (I) to 30-70 (SWE), 25 (UK). Spain reported 350 passed homes per distribution area.
+
+**I.2.5** Inside building network: The topology is point-to-point or point-to-multipoint. The transmission media are symmetrical copper pairs, and/or coaxial pairs and the installation is in ducts and wall mounted.
+
+## **I.3 Cable construction**
+
+**I.3.1** Transport network: The type of cable installation is in-duct and/or aerial. The optical fibre utilized is a SM one. The optical fibre cable sheath design is a PKH9E, PKH5E (E: polyethylene inner sheath, K: aramidic yarn, H9: corrugated steel tape, E: polyethylene outer sheath, H5: aluminium tape) a polyethylene or a metalfree. The optical fibre cable core design is mainly loose tube or slotted core stranded filled cables. The number of fibres per cable is 12 to 60 (I), up to 300 (JP), between 16 and 128 (ES), 24F, 48F, 96F (SWE), 8 (UK).
+
+**I.3.2** Access network: The cable type is normally an induct cable and the optical fibre cable type is a SM fibre while the optical fibre cable sheath design is a PKH9E, PKH5E, a polyethylene or metalfree. The optical fibre cable core design is a loose tube or a slotted core stranded filled one.
+
+The number of fibres is 12-60 (I), up to 1000 (JP), between 2 and 8 per tube, between 16 and 128 per cable (ES), 4-24(4-fibre ribbons) (SWE), 8 (UK).
+
+**I.3.3** Subscriber access. The cable type is duct or aerial; the optical fibre cable type is with SM fibres; the optical fibre cable sheath design is a EKH9E, a metalfree or a polyethylene. The optical fibre cable core design is generally a loose tube or a slotted one with fibre ribbons, and the number of fibres is 5 ribbons per slot (20-40 fibres per slot) (I), up to 1000 cores slotted rods and 4 or 8 optical fibres ribbons (JP), 4F-24F (SWE), 8 up to 96 (UK).
+
+In Japan there is no coaxial cable utilized. Elsewhere coaxial trunk and drop cables are used.
+
+The conductor diameter of the trunk cables varies from 3.15 to 13.7 mm or 2.64 to 11.5 mm. The attenuation is between 4.7 and 5.8 dB/100 m.
+
+Drop cables usually have a conduct diameter between 1.02 and 4.6 mm, and an attenuation of 14.9 or 9.9 dB/100 m at 450 MHz.
+
+In Italy, trunk cables usually have aluminium welded tape without overlapping. Drop cables have two layer outer conductors: the first is a double aluminium tape outer, a polyester sandwich, the second layer has a tinned copper braid. Sometimes copper cables with overlapping are used (UK).
+
+**I.3.4** Inside building (installation) cables: Where in-building optical cables are used (JP, ES, SWE), SM fibres are used. RG-6 and RG-11 standard coaxial drop cables are used. The standard cable length between NT and TV set is between 10 and 20 metres.
+
+## **I.4 Components for CATV networks**
+
+**I.4.1** Optical components for CATV networks: The optical transmitter uses SM fibres at 1550 nm with a bandwidth up to 862 MHz with about 20 analogue and 70 digital TV video and audio channels (I); SM fibres, 1310 nm and 1550 nm and a band up to 862 MHz (ES); 1310 nm or 1550 nm (SWE); SM fibres, 1310 nm and up to 862 MHz (UK).
+
+The optical amplifiers use SM fibres in the third window in every country.
+
+The optical receivers use SM fibres in the third and second window with a bandwidth up to 862 MHz.
+
+The fibre splitters use SM fibres; the wavelengths are at 1310 nm and 1550 nm; in the table below the splitting ratios adopted are reported.
+
+| Italy | Spain | Sweden | United Kingdom |
+|------------------|---------------------------------------|---------------------------|-------------------------------|
+| 2-4-8-12 outputs | 1x8, 1x16, 1x32, 2x4, 2x8, 2x16, 2x32 | 1x2, 1x4, 1x8, 1x16, 1x32 | 1x3, 1x4, 1x8 only at 1310 nm |
+
+**I.4.2** Coaxial components for CATV networks: The connectors used for drop cables are type F with a return loss $\geq 30$ dB, type 5/8, for trunk cables with a return loss $\geq 30$ dB (I). In Spain the type F is also used together with 5/8-24 or EN60169-24, the return loss is $\geq 30$ dB. In Sweden there are problems with poor connectors in the CATV network; the standards adopted are EN50083-2 and EN50083-4. In the United Kingdom type F, 5/8 and M14 coaxial connectors are used.
+
+Coaxial splitters for trunk cables have splitting ratios of 2, 3 or 4 typically.
+
+Directional couplers have splitting ratios of 2, 8, 12.
+
+Taps have a number of ports that vary from 2 to 16 with an insertion loss that varies consequently between 5.2 and 24 dB.
+
+Regarding the active coaxial components there are usually three amplifiers: launch, extender and last amplifier.
+
+## **I.5 Cable installation**
+
+**I.5.1** Cable type: Duct, aerial and inside building installation (I), (JP), (ES), (UK), for optical, coaxial and symmetrical copper pairs cables.
+
+**I.5.2** Installation methods: They include typically pulling. The blowing technique is also adopted (ES, UK) for optical cables.
+
+**I.5.3** Installation lengths: They vary with the country.
+
+In Italy, the installation length is about 1-3 km for in-duct optical cables; optical cables are not used inside buildings. The installation length reaches the 500 m maximum in in-duct coaxial cables, 100 m in inside building coaxial drop cables. Symmetrical copper pairs cables reach 500 m in length typically in duct.
+
+In Japan there are duct cables with an average length of 1 km and aerial cables of around 500 m. Inside building cables reach an average length of 300 m.
+
+In Spain installation length is between 1 and 2 km.
+
+In Sweden, cable length is normally about 2-4 km for optical cables, and 200-300 m for coaxial cables.
+
+**I.5.4** Method of aerial installation: The methods are different, depending on the type of the cable.
+
+In Italy the methods are wrapping and lashing for optical cables, wall installation for coaxial cables and lashing for symmetrical copper pair cables. In the other countries the method usually adopted is the self-supporting one.
+
+## **I.6 Cabinet installation**
+
+**I.6.1** Use of the cabinet: A lot of cabinets are used for fibre nodes, line extenders, last amplifiers, splitters and outdoor taps in HFC-C networks.
+
+**I.6.2** Installation type: The places of installation are the road, aerial or inside building; then, depending on the possibilities, they can be: underground, curb, inside building, wall and flat roof.
+
+The main characteristics of the cabinets are reported in the following table:
+
+| | Italy | Japan | Spain | Sweden | United Kingdom |
+|------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------|-----------------|------------------------|----------------|
+| Dimension in cm | – FN cabinets: 75x152x32 (curb)/168x87x83 (underground) – LE, LA cabinets: 75x124x32(curb)/90x35x40 (underground)/71x65x24 (in building) – Taps: 33x96x29(curb)/34x48x25, 33x52x30 (in building) | 60x20x10 | different types | 70x90x30 | 120x100x75 |
+| Material | Plastic | Metal | Plastic | Galvanized steel sheet | Metal |
+
+**I.6.3** The thermal compensation is passive.
+
+**I.6.4** Internal elements: They depend on the type of the cabinet. They can be optical fibres, coaxial and copper pairs, with a configuration that can be rigid or flexible, mainly depending on the type of the cabinet.
+
+# APPENDIX II
+
+## Italian experience on HFC-C networks1
+
+## II.1 Introduction
+
+In 1995, Telecom Italia chose a Hybrid Fibre Coax (HFC-C) architecture for the distribution of broadband and multimedia services in the Italian access network according to a Sub-Carrier Multiplexing (SCM) Passband transmission technique.
+
+HFC-C network design and construction were particularly complex in Italy, due to Telecom Italia's high quality level requirements and to the variety of urban and administrative situations.
+
+This appendix summarizes the field experiences and the most important particular solutions developed for the HFC-C project, from the designer's and the installer's points of view.
+
+## II.2 The HFC-C project
+
+Recently, growing availability of broadband services, higher quality requirements for traditional services and the liberalization of the European telecommunication market, have forced operators towards new access network technologies.
+
+In the case of Telecom Italia, the HFC-C project had the target to gradually develop a broadband network platform according to the following three phases:
+
+- Phase 1: analogue video services distribution and preparation for digital video transmission;
+- Phase 2: video distribution and multimedia interactive on-line services;
+- Phase 3: video distribution and multimedia interactive services with integration of traditional narrow-band services.
+
+1 BOTTANELLI (M.), COTTINO (E.): "Building Italian Hfc Broadband Distribution Network: Field experiences and special installation solutions, *46th International Wire and Cable Symposium*, Philadelphia (USA) – 17-20 November 1997.
+
+In the technical solution for the HFC-C project phase 1 (Sub-Carrier Multiplexing Passband transmission) analogue and digital signals are multiplexed by means of suitably spaced radio frequency (RF) sub-carriers: the resulting signal modules an optical carrier which is transmitted to the network peripheral nodes.
+
+The reference architecture for the HFC-C project phase 1 is sketched in Figure II.1, according to the following node classification:
+
+- *Head End (HE)*: the centre where different video signal sources are processed and organized to become available on the network;
+- *Distribution Node (DN)*: the network entry point for channels coming from different HEs. In the DN, video signals are put on the available transmission band by means of frequency multiplexing. A DN typically serves a metropolitan area and its suburbs;
+- *Local Node (LN)*: this network node receives signals from the DN and parts them on the urban distribution area FNs;
+- *Fibre Node (FN)*: this network node converts the optical signal into an electric one and distributes it by means of a tree-like coaxial network. An FN typically serves a maximum distribution area of 400 homes;
+- *Last Amplifier (LA)*: the last amplification point before distribution to the customers. In the case of low signal levels (very broadened customer area) it is often necessary to add a further amplification point on the trunk network between FN and LA ("Line Amplifier" or "Line Extenders").
+
+
+
+The diagram illustrates the HFC-C architecture for project phase 1, divided into two main sections by a vertical dashed line. The left section, labeled 'Services generation and transport', shows a 'Head End (HE)' building with a satellite dish on its roof, connected to a 'Distribution Node (DN)' building below it. The right section, labeled 'Services distribution', shows a 'Local Node (LN)' building connected to a 'Fibre Node (FN)' building. The FN is connected to a 'Last Amplifier (LA)' building, which in turn connects to a tree-like network of customer premises (houses and a building). The diagram is labeled with 'T0604970-00' in the bottom right corner.
+
+Diagram of HFC-C architecture for project phase 1
+
+**Figure II.1/L.47 – HFC-C architecture for the project phase 1**
+
+From HE to DN channels are transported by means of SDH 34 Mbit/sec links; from DN to LN analogue transmission is carried out by means of optical regional network; from LN to FN optical fibres of the primary distribution network are used; finally, from FN to LA and up to the customer NT ("Network Termination") transmission is carried out by means of a tree-like amplified coaxial network for 500 metres typical maximum link lengths.
+
+The coaxial part of the network limits the available bandwidth to 1 GHz according to the following targets:
+
+- from 5 up to 30 MHz for network control signalling and interactive services upstream transmission;
+- from 54 up to 470 MHz for analogue video distribution;
+- from 470 up to 862 MHz for digital video distribution, telephony and data transmission;
+- from 862 up to 1000 MHz, the band is available for future applications.
+
+## II.3 Network infrastructure for Italy
+
+Different problems had to be solved in order to implement the above-described HFC-C architecture in the field, because of both Telecom Italia requirements and the different urban and administrative situations in Italy.
+
+Table II.1 summarizes in very general terms the three basic cable installation techniques for the access network according to their cost, reliability and flexibility characteristics. As in the past, Telecom Italia chose cable in-duct installation with operation, connection, and distribution manholes. This is the most expensive solution but the most reliable and flexible too, considering Italy's needs and future evolution of the network.
+
+**Table II.1/L.47 – Cable installation techniques**
+
+| | Cost | Reliability | Flexibility |
+|---------------|--------|-------------|-------------|
+| Aerial | Low | Low | Medium |
+| Buried | Medium | Medium | Low |
+| Duct | High | High | High |
+
+Less expensive HFC-C architectures can be designed for simplified contexts by means of the following solutions (see Table II.2):
+
+**Table II.2/L.47 – Solutions for less expensive HFC-C networks**
+
+| |
+|-------------------------------------------------------|
+| • Frequent wall and pole installation |
+| • Low depth cable duct installation (30 cm) |
+| • More than one cable in the same duct |
+| • Limited cabinet numbers and typology |
+| • Different services (HFC-C+FTTC) in the same cabinet |
+| • Twin cables (coax and t.p.) for customer connection |
+
+In every case, an HFC-C architecture automatically implies the presence of active elements in the field. Figure II.2 summarizes coaxial components according to their cabinet or their housing in the network.
+
+
+
+The diagram illustrates the internal components of three types of cabinets used in a coaxial network:
+
+- Fibre node cabinet:** Contains five components:
+ - electro-optical converter (solid line circle)
+ - launch amplifier (solid line circle)
+ - optical termination (dashed line circle)
+ - coaxial network power supply (solid line circle)
+ - connectors, splitters, power inserters (dashed line circle)
+- Last amplifier cabinet:** Contains two components:
+ - last amplifier (solid line circle)
+ - connectors, splitters, taps (dashed line circle)
+- Passive elements housing / User outlet housing:** Contains two components:
+ - connectors and taps (dashed line circle)
+ - network termination (dashed line circle)
+
+Diagram showing the internal components of three cabinets: Fibre node cabinet, Last amplifier cabinet, and a combined Passive elements housing and User outlet housing. Active components are circled with solid lines, and passive components are circled with dashed lines.
+
+T0604980-00
+
+**Figure II.2/L.47 – Coaxial network elements and cabinets**
+
+Among them, the ones circled with a continuous line are active, and may dissipate from 15-35 Watts (RF amplifiers) up to 100-150 Watts (FN coaxial network power supply).
+
+FN and LA cabinets are commonly installed on curbs, while passive component housings can be installed both on curbs and in customer buildings. The following simple estimate can give an idea of the HFC-C network environmental impact: in the circular area around a FN, there are typically 6 LA cabinets and about 20 passive component housings.
+
+For these reasons, the physical construction of such a network had to face a lot of limitations, according to the ground morphology, customer distribution, administration requirements, the presence of historical monuments, and so on.
+
+Limitations and requirements might change according to different cities in a very dramatic way, so that what was requested in some areas was strictly forbidden in others. Table II.3 summarizes some of the typical HFC-C network different installation requirements or situations for Italy.
+
+**Table II.3/L.47 – HFC-C network different installation requirements**
+
+| |
+|------------------------------------------------|
+| • Underground LA installation only |
+| • Forbidden underground LA installation |
+| • Built-in wall LA cabinets |
+| • On curb excavations only |
+| • On grade excavations only |
+| • Forbidden parallel excavations |
+| • Crossing excavations near cross-roads only |
+| • Use of no-dig techniques when possible |
+| • Air installation highly recommended (Venice) |
+| • Frequent use of line amplifier |
+
+In order to meet so many different requirements, different solutions concerning installation techniques and cabinet types and locations were developed and experimented. Examples of these solutions are listed in the following points:
+
+- Directional drilling (Figure II.3), air, pole, and wall installation techniques were adopted to limit HFC-C network environmental impact.
+
+
+
+Figure II.3/L.47 – Scheme of the directional drilling technique. The diagram illustrates the process of directional drilling in three stages. The top stage shows a 'drilling machine' on the surface connected by a cable to a 'drilling head locator' (represented by a person). A 'pilot-hole drilling' arrow points from the machine towards a 'manhole'. A distance of '100-150 m max.' is indicated between the manhole and the drilling head. The middle stage shows 'duct pulling-back' with an arrow pointing from the manhole back towards the drilling machine. The bottom stage shows a detailed view of the 'drilling head' with arrows indicating its rotation and forward movement.
+
+**Figure II.3/L.47 – Scheme of the directional drilling technique**
+
+- On curb FN and LA cabinets were derived from traditional twisted pairs distribution cabinets by means of careful calculation and proper design of heat dissipation (more than 300 Watt) louvres for natural convection.
+- 300 twisted pairs Telecom Italia old cabinet modules were adapted for in-building installation of a LA and two taps.
+- Underground waterproof sheet moulding compound LA cabinet (Figure II.4) was developed for installation into manholes.
+
+
+
+Figure II.4/L.47 – Underground LA cabinet sketch. This is a top-down technical drawing of an underground LA cabinet. The cabinet is rectangular with rounded corners. It features an 'IN/RF' input section on the left and an 'OUT' output section on the right. Various cables and components are shown inside. The overall dimensions are labeled as 406 mm in height and 886 mm in width. The code 'T06045000-00' is visible in the bottom right corner.
+
+**Figure II.4/L.47 – Underground LA cabinet sketch**
+
+- Finally, a whole FN underground cabinet was developed.
+
+## II.4 Coaxial network design
+
+The optimization of the HFC-C network infrastructure with reference to field requirements is one of the basic coaxial network design targets. This activity proceeds according to the following different steps:
+
+- broadband connections definition;
+- walk-in;
+- walk-out;
+- catchment areas definition;
+- RF design;
+- civil design;
+- bill of materials;
+- drawing.
+
+In the Telecom Italia HFC-C network design reference guide, customer premises were classified according to broadband connection requirements as summarized in Table II.4.
+
+This first classification is followed by a detailed analysis of the horizontal and vertical premises layout ("walk-in maps") in the considered area. Moreover, by means of the so-called "walk-out maps", the network designer is informed of building entrances, suitable places for cables and cabinets installation, and of already existing infrastructures.
+
+**Table II.4/L.47 – Customer premises classification**
+
+| Type | Description | Number of BB lines |
+|------|-----------------------------------------------------------|--------------------|
+| A | apartments, offices, shops | 1 |
+| B | commercial centres, schools, < 20 rooms hotels/residences | 4 |
+| C1 | 20-80 rooms hotels/residences | 40 (1 LA) |
+| C2 | 81-150 rooms hotels/residences | 80 (2 LA) |
+| D1 | > 400 circuits business customers | 1 FN |
+| D2 | 101-400 circuits business customers | 1 FN |
+| D3 | 51-100 circuits business customers | as B or C |
+| D4 | > 150 rooms hotels/residences | 1 FN |
+
+The RF coaxial network design is then usually obtained by means of an automatic CAD (Computer Aided Design) system according to a typical bottom-up approach, proceeding from LA areas definition ("Catchment areas definition") up to FN. On the basis of a highly detailed RF component database, the designer can easily dimension all parts of the coaxial network in order to ensure at least 12 dBmV electrical signal level at the customer network termination.
+
+15.8 mm (.625 in.) and 19.1 mm (.750 in.) aluminium based trunk cables are used to connect FN to LAs and LAs to taps, while type 6 and type 11 drop cables are used for customer premises cabling. The availability of different cable types and attenuations allows minimizing the number of RF line amplifiers in the network.
+
+The civil design immediately follows the RF one: the CAD operator has to choose cabinets, manholes, and ducts typology and locations, exploiting already existing infrastructures as much as possible.
+
+Finally, the CAD system can automatically extract from the network design the bill of materials and draw the requested documentation (coaxial and civil planimetries).
+
+## II.5 Evolution towards all optical networks
+
+With reference to future developments, it is worth considering the following consequences of the project:
+
+- introduction of broadband services transmission technologies in the Italian access network;
+- arrangement of infrastructures for a possible future network expansion towards new architecture types (HFC-S for instance).
+
+While the first aspect is directly related to the project mission, the second one often risks to be underestimated.
+
+
+
+Figure II.5/L.47 – Evolution towards all optical networks: HFTTB. The diagram is split into two horizontal sections. The top section shows network architecture evolution from LN (Local Network) to FN (Fiber Network) via optical splitters. From FN, two paths emerge: one labeled 'HFC-C' leading to a 'Tap' and then to an 'NT' (Network Terminal), and another labeled 'PON' (Passive Optical Network) leading to an 'ONU' (Optical Network Unit) and then to an 'NT'. The bottom section shows the physical infrastructure evolution from LN to FN, then through a series of pipes (labeled 'two 63 mm empty pipes', '63 mm pipe for trunk cable', '125 mm empty pipe') to an 'LA' (Local Area) unit. From the LA, multiple pipes lead to an outlet labeled 'T0605010-00'. These pipes are labeled as '63 mm pipe for coaxial cable with a 18 mm inner empty pipe for future optical cable installation'.
+
+**Figure II.5/L.47 – Evolution towards all optical networks: HFTTB**
+
+Figure II.5 illustrates an example of the project evolution potentiality (Hybrid Fibre To The Building architecture). Here the HFC-C infrastructure is compared to a possible future passive optical network (PON) experimentation, as a first step towards all services integration.
+
+HFC-C infrastructure was in fact already arranged to support a passive optical network, with optical splitters located near FN cabinets. From FN to LA cabinets and for every HFC-C network directrix, two 63 mm and one 125 mm empty pipes were prepared for future applications. Moreover, from LA to customer premises, every 63 mm pipe for coaxial cable was equipped with an inner 18 mm empty pipe for future optical cable installation.
+
+With reference to Figure II.5, from LN to FN, HFC-C network and PON share the same optical cable ring on different fibres; from FN to customer premises they lean on the same infrastructure; finally the two networks match at the user outlet. Broadband distribution services are transmitted on the HFC-C network; traditional and broadband interactive services might be integrated and transmitted on the PON.
+
+# APPENDIX III
+
+## **Indonesia's experience on HFC-C networks Access facilities using hybrid fibre/copper networks**
+
+## **III.1 Introduction**
+
+This appendix explains several technical and electrical specifications for HFC-C network implementation in Indonesia, which refers to the Questionnaire on Access Facilities Using Hybrid Fibre/Copper Networks for Question 13/6. Some tables and a legend are given for clear information.
+
+## **III.2 Background**
+
+HFC-C was one alternative access network technology to support broadband services and interactive multimedia with several considerations. Strong reasons to implement HFC-C technology in Indonesia were such as:
+
+- Optical network had been installed as backbone network, to connect between two exchanges. This network could be used for trunk network in HFC-C to connect Headend with Distribution Hub.
+- Simple coaxial network was already available in several hotels that could be used for HFC-C applications.
+- High potential demand for television distribution, Internet services, and interactive multimedia especially for real estate area, condominium, and hotels.
+- HFC-C as "big pipe" for future bandwidth necessities and new technology in the future.
+
+HFC-C offers several kinds of multimedia services and basic communications; some are:
+
+- Telephony (POTS).
+- Broadcast TV analogue.
+- Broadcast TV digital.
+- Fast Internet.
+- On demand services: VOD (Video on Demand), MOD (Music on Demand), KOD (Karaoke on Demand).
+- Interactive multimedia.
+
+## **III.3 Network topology**
+
+### **III.3.1 Transport network topology**
+
+The topology used is a ring configuration and the transmission technology is SDH. The transmission medium is optic fibres and usually the cable installation is in duct system.
+
+### III.3.2 Access network topology
+
+Demarcation area between transport network and access network is at the headend. The headend up to customer side is called access network (Figure III.1). The transmission medium from the headend up to fibre node use to optic fibres, and from the fibre node up to customer side use to coaxial network.
+
+
+
+The diagram illustrates the access network topology. At the top left, an 'ISP' cloud and a 'Broadcast TV' satellite dish are connected to a 'HEADEND' box. The 'HEADEND' is also connected to a 'Local Exch.' box and a 'Video server' cylinder. From the 'HEADEND', an 'optic fibre' line extends to a 'Distribution Hub' box. This 'Distribution Hub' is connected to a 'Local Exch.' box. From this 'Distribution Hub', another 'optic fibre' line extends to a 'Fibre Node' box. This 'Fibre Node' is connected to two 'coaxial network (tree and branch)' lines, each leading to a house icon. From the first 'Fibre Node', another 'optic fibre' line extends to a second 'Distribution Hub' box. This 'Distribution Hub' is connected to a 'Local Exch.' box. From this 'Distribution Hub', another 'optic fibre' line extends to a second 'Fibre Node' box. This 'Fibre Node' is connected to three 'coaxial network (tree and branch)' lines, each leading to a house icon. The text 'coaxial network (tree and branch)' is written next to the first set of connections. The diagram is labeled 'T0605020-00' in the bottom right corner.
+
+Diagram of access network topology showing the flow from ISP and Broadcast TV through a Headend and Distribution Hubs to Fibre Nodes and finally to customer homes via a coaxial network.
+
+T0605020-00
+
+**Figure III.1/L.47 – Access network topology**
+
+### III.3.3 Coaxial network topology
+
+The topology of coaxial networks is tree and branch (Figure III.2). The cable types are both aerial and duct system. Commonly, each fibre node supports about 500 homepass whereas capacities homepass each fibre node depends on the services that will be delivered to the customer.
+
+
+
+Diagram of a coaxial network topology connected to a fibre node. The diagram shows three main branches originating from a central fibre node. The top branch consists of a trunk cable, a TAP with an outlet, a line amplifier, another TAP with an outlet, a trunk cable, and a 75 Ω terminator. The middle branch starts with a trunk cable, a trunk amplifier, and a directional coupler. One output of the coupler leads to a trunk cable, a TAP with an outlet, a line amplifier, another TAP with an outlet, a trunk cable, and a 75 Ω terminator. The other output of the directional coupler leads to a bridger amplifier. From the bridger amplifier, one output goes through a feeder cable, a TAP, a line amplifier, a drop cable with an outlet, a TAP, and a 75 Ω terminator. The second output from the bridger amplifier goes through a feeder cable, a TAP, a line amplifier, a feeder cable, a TAP, and a 75 Ω terminator.
+
+T0605030-00
+
+**Figure III.2/L.47 – Coaxial network topology**
+
+## III.4 Cable construction
+
+### III.4.1 Optical cabling
+
+The optical transmitter uses single mode fibres at 1310 nm and 1550 nm. Cable specification is G.652. Distribution fibre network can be point-to-point and point-to-multipoint. For point-to-multipoint configuration the fibre is split by an optical passive splitter 1: n.
+
+### III.4.2 Coaxial cabling
+
+Coaxial cable was divided into trunk/feeder cable and drop cable.
+
+- Trunk/feeder cable that TELKOM recommended were cables with diameter of 0.500; 0.625; 0.750; 0.875 and 1.00 inch.
+- For drop cable RG-6; RG-11 and RG-59 were recommended.
+
+If we look at the cable's application function, the kind of coaxial cable was the same with other cable, it was divided into direct buried cable, duct cable and aerial cable. TELKOM did not recommend Siamese cable for double coaxial, but it was possible for the twisted pair built-in coaxial cable for powering purposes.
+
+In the application, selection of the type of cable was usually determined by the condition of boundary area homepass. If the boundary for trunk/feeder network was very wide, we could choose a trunk/feeder cable with a large diameter, because that kind of cable had lower loss cable. For special conditions in the customer side, for example, the existence of so much noise and interference, it was better to use drop cable with double protections (quad shield or tri shield). Normally, the boundary for coaxial network was about 1 km2 up to 2 km2 .
+
+## III.5 Bandwidth allocation
+
+For the beginning of implementation of HFC-C, bandwidth allocation that was standardized by TELKOM was up to 862 MHz (see Figure III.3). It was possible to increase the bandwidth up to 1 GHz for the future services if needed. The same with upstream bandwidth that recommended up to 40 MHz, could be increased if there were additional services for upstream. The guardband between upstream and downstream was recommended to be 10 MHz.
+
+
+
+The figure illustrates the bandwidth allocation for an HFC-C system. The horizontal axis represents frequency in MHz, with markers at 0, 40, 50, 450, 550, and 862. The spectrum is divided into three main segments:
+
+- Upstream:** From 0 to 40 MHz, indicated by a double-headed arrow above the axis.
+- Guardband:** From 40 to 50 MHz, indicated by a dashed double-headed arrow above the axis.
+- Downstream:** From 50 to 862 MHz, indicated by a long double-headed arrow above the axis.
+
+Below the axis, the downstream section is further subdivided into three contiguous rectangular blocks representing different service types:
+
+- From 50 to 450 MHz.
+- From 450 to 550 MHz.
+- From 550 to 862 MHz.
+
+Figure III.3/L.47 – Bandwidth allocation for HFC-C system. The diagram shows a frequency spectrum from 0 to 862 MHz. The spectrum is divided into three main sections: Upstream (0 to 40 MHz), Guardband (40 to 50 MHz), and Downstream (50 to 862 MHz). The Downstream section is further divided into three sub-sections: 50 to 450 MHz, 450 to 550 MHz, and 550 to 862 MHz.
+
+T0605040-00
+
+**Figure III.3/L.47 – Bandwidth allocation for HFC-C system**
+
+- From 0 up to 40 MHz:
+For telephony, upstream data communication, control signal for VOD, and management signal.
+- From 40 up to 50 MHz:
+Guardband between upstream and downstream.
+- From 50 up to 450 MHz:
+For TV analogue broadcast and radio FM broadcast.
+- From 450 up to 550 MHz:
+For TV digital broadcast (Pay per Channel, Pay per View and Near VOD).
+- From 550 up to 862 MHz:
+For telephony, data communication, real VOD.
+
+## III.6 System configuration
+
+Figure III.4 gives a common configuration of an HFC-C network. TELKOM recommended only one headend to the entire HFC-C network in one location. For example Jakarta, Bandung and Surabaya are big cities; TELKOM considered it ideal that there was only one headend in each city. The optical network from headend to distribution could reach about 30 km, also for the optical network to the
+
+fibre node. System configuration in the distribution hub depended on service provider arrangements. If the service provider just gave an Internet application, there was no need for cable telephony headend and video interactive headend in the distribution hub. The service provider just presented the cable data headend that connected to the ISP or data source service and gave a cable modem to the customer, without STB (Set Top Box). It was possible if in the network there was no distribution hub, just only the headend, or distribution hub and headend in one location and one system.
+
+
+
+The diagram illustrates the HFC-C system configuration. On the left, a house is connected to a 'coaxial network' which leads to a 'FIBRE NODE'. The fibre node connects to a 'DISTRIBUTION HUB' via an optical link (indicated by a circle with two arrows). Inside the distribution hub, the optical signal is converted by an 'E/O' (Electro-Optical) and 'O/E' (Optical-Electrical) pair. The signal then splits: one path goes to a 'Combiner', and the other goes to a 'Splitter'. The 'Combiner' is connected to an 'O/E' device which links to a 'HEADEND'. The 'HEADEND' is connected to a satellite dish and a terrestrial antenna. The 'Splitter' in the distribution hub connects to three headends: 'Video Interactive Headend', 'Cable Data Headend', and 'Cable Telephony Headend'. These headends are connected to external networks: the 'Video Interactive Headend' to an 'ATM Network' which is connected to a 'Video server'; the 'Cable Data Headend' to a 'Data Network'; and the 'Cable Telephony Headend' to a 'PSTN/ISDN Exchange'. A small text label 'T0605050-00' is visible at the bottom right of the diagram.
+
+Diagram of HFC-C system configuration showing the flow from a house through a fibre node to a distribution hub, which then connects to a headend and various service networks.
+
+**Figure III.4/L.47 – HFC-C system configuration**
+
+### III.6.1 Headend
+
+The headend had functioned as a centre of broadcast TV services, for both analogue and digital TV. For one HFC-C area services, TELKOM recommended one headend location for all customer/homepass. The headend would be connected to one or several distribution hubs. The service source for broadcast TV came from TV satellite, local TV (off air) and digital TV microwave terrestrial.
+
+### III.6.2 Distribution hub
+
+The distribution hub combined broadcast TV services from the headend to other services depending on application in that area. Services could be VOD from one video server, Internet to connect to one ISP and telephony from the local exchange. The distribution hub could be implemented in several locations in the local exchange. It was also possible that the headend and distribution hub were in the same location (co-located). Usually the distribution hub used optical backbone/junction networks that were already used for connection between two exchanges. Almost all big cities in Indonesia had already used optical network as a junction connection.
+
+Besides that, another consideration was access capability to ISP location and access to PBX or exchange location. Consideration whether TELKOM would act as only the network provider or become the service provider would change the global system configuration, especially whether the limit between network provider and service provider was in the distribution hub or started from opto-transceiver devices from combiner if TELKOM acted just as the network provider.
+
+### III.6.3 Fibre node
+
+Fibre node as active component had a function to convert RF signal to optic signal or vice versa. Usually one fibre node was designed for about 500 up to 1000 homepass, depending on the kind of services that would be implemented and customer boundary/cluster.
+
+The number of leg outputs from the fibre node should be a maximum of 3 legs of which each leg could be high-level output or low-level output. High-level output was usually used to cover big homepass that was very far from the fibre node and also for the distribution network, since low-level output was used to cover homepass not far from the fibre node and not a very big homepass. High-level output was about 47 dBmV and low-level output was about 32 dBmV. The output leg from the fibre node could be added by using a splitter or a directional coupler.
+
+### III.6.4 Amplifier (active component)
+
+TELKOM standardized three kinds of amplifier from their function. They were trunk amplifiers, bridger amplifiers and line extender amplifiers. Each kind of amplifier also had a different leg output. Usually the trunk amplifier just had one input and one output, and the bridger amplifier had two legs output. The important thing from amplifier characteristics was noise or distortion. So TELKOM recommended that the maximum cascade amplifiers were four, both for similar amplifiers or different amplifiers in one route (Figure III.5).
+
+
+
+Diagram of a cascade amplifier configuration. A horizontal line represents the main cable. Along this line, from left to right, there are three amplifiers (represented by triangles pointing right). Between the first and second amplifier, a vertical line branches down to a pair of amplifiers (triangles pointing down). Between the second and third amplifier, another vertical line branches down to a pair of amplifiers (triangles pointing down). The first pair of amplifiers is labeled 'cascade I: 3 amplifiers'. The second pair is labeled 'cascade II: 4 amplifiers'. The word 'amplifier' is written between the two pairs. The diagram is labeled 'T0605060-00' in the bottom right corner.
+
+**Figure III.5/L.47 – Cascade amplifier**
+
+### III.6.5 Passive component
+
+Passive components contained three components; the first was tap as splitting signal component from drop cable to the customer side, the second was splitter and the last was directional coupler to split the signal with some loss.
+
+- There were 3 kinds of TELKOM's standard splitter; 2 ways, 3 ways and 3 ways unbalance.
+- For the directional coupler there were 3 kinds, DC 8 dB, DC 12 dB and DC 16 dB.
+- For tap there were also 3 kinds of tap that TELKOM standardized; 2 ways output, 4 ways and 8 ways outputs with insertion loss value from 8 dB up to 29 dB.
+
+Consideration for output 8-way maximum for tap was the drop cable distance from tap to the customer side. It was estimated that for drop cable configuration both star and straight length of drop cable from tap to customer side should be no more than 100 metres. As we know, loss drop cable for star and straight configuration (Figure III.6) was very high, about 10 up to 12 dB in each 100 metres, compared with trunk/feeder cable that only had about 3 dB loss each 100 metres. With 8-ways tap, ideally this tap can be used, at the maximum, only for 4 homepass at right and left side. Special cases for condominium and hotels where the outlet location was not a similar model as with the residential area.
+
+
+
+Figure III.6/L.47 – Drop cable connection to homepass. The diagram shows two methods of connecting a drop cable to a homepass. The left method shows a drop cable branching off a cable route via a tap. The right method shows a drop cable branching off a cable route via a homepass. Labels include 'homepass', 'cable route', 'drop cable', and 'tap'. A reference code 'T0605070-00' is present.
+
+**Figure III.6/L.47 – Drop cable connection to homepass**
+
+### III.7 Powering system
+
+Power was sent from fibre node in range 60 up to 90 V ac, and 10 up to 15 Ampere. To deliver power to amplifier there were two methods, distribution system or centralized. The distribution system was more complex because we should locate several power inserters for all amplifiers and also should manage the power flow with blocking power equipment in some amplifiers to avoid one amplifier getting power from some power supply. On the other hand, the centralized system was simpler, because we gave power just from one location, usually together in the fibre node cabinet.
+
+### III.7.1 Powering system in coaxial cable
+
+- a) Use Siamese cable (combined with twisted pair, see Figure III.7).
+
+Power was delivered in twisted pair, not in coaxial cable. Usually there were some PDU (Power Distributed Unit) in tap to deliver power in the drop cable.
+
+
+
+Figure III.7/L.47 – Siamese cable for powering. The diagram shows a cross-section of a Siamese cable, which consists of a coaxial cable and a twisted pair. Labels include 'coaxial cable', 'twisted pair', and 'cable jacket'. A reference code 'T0605080-00' is present.
+
+**Figure III.7/L.47 – Siamese cable for powering**
+
+- b) Use single cable (in coaxial itself).
+
+This method had a corrosion effect bigger in the conductor because the conductor became hotter from the powering system.
+
+## III.8 Outside plant (OSP)
+
+### III.8.1 Pole
+
+Because the coaxial network was still new in Indonesia, so in the application, the coaxial route could be implemented in a similar route with the copper network or a different route. For aerial application, we could pole together with telephony pole, power pole or separate pole depending on the condition and regulation in each country. The minimum distance between coaxial cable and power cable was 30 cm, and the coaxial cable had to be under the power cable. This regulation considered a higher poor cable interference factor. All amplifier positions should be at the pole, not in the middle of the pole, except passive components like splitter and tap which could be in the middle of the route.
+
+### **III.8.2 Cabinet**
+
+All amplifiers and passive components on direct buried route and duct cable had been installed on cabinet or pedestal. The cabinet was made of a hot resistance isolation component supported by fibreglass components. The physical requirement of this cabinet was similar to other cabinets that were used for copper or ONU, such as good material, good corrosion resistance, water and snow protection and also had ventilation to avoid any condensation process. The cabinet also had a grounding of not more than 3 ohm. Power supply for fibre node in the cabinet should have a battery as a backup system. Splitters for leg branches in the fibre node had to be placed inside the cabinet or directly out from the fibre node amplifier. The cabinet also should have a protection pillar to protect the cabinet from crash impact.
+
+## **III.9 Standardization**
+
+TELKOM had published some documents of standardization for each component, system, and also installation guidelines for HFC-C technology implementation. All standards contained rules, and requirements of technical aspects and electrical aspects for each device and system. Below are completed standards for HFC-C systems that were published by the R&D Division of PT TELKOM. Along with the process, this document could be edited and corrected according to technology development and some process of modification.
+
+- a) CIU (Customer Interface Unit) – HFC.
+- b) STB (Set Top Box) – HFC.
+- c) Cable Modem – HFC.
+- d) Coaxial cable – HFC.
+- e) Passive components – HFC.
+- f) Amplifier – HFC.
+- g) Fibre Node – HFC.
+- h) HEADEND – HFC.
+- i) Cable Telephony – HFC.
+- j) Cable Router – HFC.
+- k) System Standardization of HFC.
+- l) Installation Guideline for coaxial network.
+
+## **III.10 Coaxial network planning tool**
+
+The R&D Division of PT TELKOM had made software to help the planning process and designing of the network, especially for the coaxial network. We called this software "TelCoNet" which stands for TELKOM Coaxial Network planning tools. This software has the ability to help design, process and network planning. Below are several capabilities of this software:
+
+- 1) Location map as drawing input could be in the form of raster file (bmp, jpeg, tif) or vector format CAD (dwg).
+- 2) To calculate downstream and upstream signal level starting from fibre node up to the demarcation point in the customer side.
+- 3) To calculate noise and distortion that occurred such as CSO (Composite Second Order), CTB (Composite Triple Beat), XMOD (Cross Modulation) and HUM modulation.
+- 4) To calculate power consumption both using a distributed powering system or centralized powering.
+- 5) To calculate BoQ (Bill of Quantity) of all the cable infrastructure, amplifier and passive components.
+
+- 6) To calculate the total budget that should be invested to buy all the network infrastructure.
+
+## III.11 Component for coaxial HFC-C networks
+
+| | |
+|--------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Splitter: a) Splitting ratio b) Number of output ports c) Insertion loss d) HUM modulation e) Power passing | a) Splitting ratio: 1/2; 1/3; 1/3 unbalance. b) Number of output ports 2 or 3. c) Insertion loss 2 way splitters: (maximum) 4.1 up to 5.5 dB. d) Insertion loss 3 way splitters: (maximum) 7.8 up to 9.2 dB. e) HUM modulation minimum 70 dB. f) Power passing 10 Ampere. |
+| Directional Coupler: a) Splitting ratio b) Insertion loss c) Directivity d) HUM modulation e) Power passing | a) Splitting ratio: 8 dB, 12 dB, and 16 dB. b) Insertion loss DC 8 dB: (maximum) 2.2 up to 4 dB. Insertion loss DC 12 dB: (maximum) 1.5 up to 3.3 dB. Insertion loss DC 16 dB: (maximum) 2.0 up to 3.3 dB. c) Directivity: under consideration. d) HUM modulation minimum 70 dB. e) Power passing 10 Ampere. |
+| Tap: a) Number of ports b) Insertion loss c) Return loss d) Insulation among parts e) Power passing | – Number of ports: 2, 4 and 8 way outputs. – Insertion loss 2 ways tap: (maximum) 0.7 up to 5.5 dB. Insertion loss 4 ways tap: (maximum) 0.7 up to 5.5 dB. Insertion loss 8 ways tap: (maximum) 0.8 up to 5.5 dB. – Return loss 2 ways tap: (minimum) 16 up to 20 dB. Return loss 4 ways tap: (minimum) 16 up to 20 dB. Return loss 8 ways tap: (minimum) 16 up to 20 dB. – Insulation loss: minimum 18 dB. – Power passing 6 Ampere. |
+| Amplifier | – Trunk amplifier – Bridger amplifier – Line extender amplifier |
+| Powering system | – Distributed system or centralized system. – 60 up to 90 V AC. – Power passing maximum 15 Ampere. – Back up battery. |
+| Materials | – Housing should be completed by seals that resist water and humidity. – The components should be operated in an environment with temperatures from 10° C up to 50° C. – The components should be protected from EMI minimum (–100 dB). – The components should be resistant to water pressure 10 psi minimum 60 seconds inside water. – Hum modulation minimum 70 dB. – Power passing 10 Ampere. |
+
+## III.12 Legend
+
+To make similar concepts and one perception, the R&D Division published the legend for a coaxial network. This legend should be used in the planning and design process, especially in drawing network. This legend was also used in our software, TelCoNet.
+
+
+
+Fibre Node symbol: a circle with two arrows pointing in opposite directions, next to a triangle.
+
+Fibre Node
+
+
+
+Trunk Amplifier symbol: a triangle with a dot at its center.
+
+Trunk Amplifier
+
+
+
+Bridger Amplifier symbol: a triangle with three dots along its left side.
+
+Bridger Amplifier
+
+
+
+Line Extender Amplifier symbol: a triangle with two dots along its left side.
+
+Line Extender
+Amplifier
+
+Splitter 2 ways symbol: a circle with the number 2 inside.
+
+Splitter 2 ways
+
+
+
+Splitter 3 ways symbol: a circle with the number 3 inside.
+
+Splitter 3 ways
+
+
+
+Splitter 3 ways unbalance symbol: a circle with the number 3 inside and a dot on the right side.
+
+Splitter 3 ways
+unbalance
+
+Directional Coupler 8 dB symbol: a circle with a horizontal line and the number 8 inside.
+
+Directional Coupler
+8 dB
+
+Directional Coupler 12 dB symbol: a circle with the number 12 inside.
+
+Directional Coupler
+12 dB
+
+Directional Coupler 16 dB symbol: a circle with the number 16 inside.
+
+Directional Coupler
+16 dB
+
+Tap 2 ways output (tap loss 8 dB) symbol: a circle with the number 8 inside.
+
+Tap 2 ways output
+(tap loss 8 dB)
+
+Tap 2 ways output (tap loss 11 dB) symbol: a circle with the number 11 inside.
+
+Tap 2 ways output
+(tap loss 11 dB)
+
+Tap 4 ways output (tap loss 26 dB) symbol: a square with the number 26 inside.
+
+Tap 4 ways output
+(tap loss 26 dB)
+
+Tap 4 ways output (tap loss 29 dB) symbol: a square with the number 29 inside.
+
+Tap 4 ways output
+(tap loss 29 dB)
+
+Tap 8 ways output (tap loss 14 dB) symbol: a hexagon with the number 14 inside.
+
+Tap 8 ways output
+(tap loss 14 dB)
+
+Tap 8 ways output (tap loss 17 dB) symbol: a hexagon with the number 17 inside.
+
+Tap 8 ways output
+(tap loss 17 dB)
+
+Tap 8 ways output (tap loss 20 dB) symbol: a hexagon with the number 20 inside.
+
+Tap 8 ways output
+(tap loss 20 dB)
+
+Tap 2 ways output (tap loss 14 dB) symbol: a circle with the number 14 inside.
+
+Tap 2 ways output
+(tap loss 14 dB)
+
+Tap 2 ways output (tap loss 17 dB) symbol: a circle with the number 17 inside.
+
+Tap 2 ways output
+(tap loss 17 dB)
+
+Tap 2 ways output (tap loss 20 dB) symbol: a circle with the number 20 inside.
+
+Tap 2 ways output
+(tap loss 20 dB)
+
+Tap 2 ways output (tap loss 23 dB) symbol: a circle with the number 23 inside.
+
+Tap 2 ways output
+(tap loss 23 dB)
+
+Tap 2 ways output (tap loss 26 dB) symbol: a circle with the number 26 inside.
+
+Tap 2 ways output
+(tap loss 26 dB)
+
+Tap 2 ways output (tap loss 29 dB) symbol: a circle with the number 29 inside.
+
+Tap 2 ways output
+(tap loss 29 dB)
+
+Tap 4 ways output (tap loss 11 dB) symbol: a square with the number 11 inside.
+
+Tap 4 ways output
+(tap loss 11 dB)
+
+Tap 4 ways output (tap loss 14 dB) symbol: a square with the number 14 inside.
+
+Tap 4 ways output
+(tap loss 14 dB)
+
+Tap 4 ways output (tap loss 17 dB) symbol: a square with the number 17 inside.
+
+Tap 4 ways output
+(tap loss 17 dB)
+
+Tap 4 ways output (tap loss 20 dB) symbol: a square with the number 20 inside.
+
+Tap 4 ways output
+(tap loss 20 dB)
+
+Tap 4 ways output (tap loss 23 dB) symbol: a square with the number 23 inside.
+
+Tap 4 ways output
+(tap loss 23 dB)
+
+Tap 8 ways output (tap loss 23 dB) symbol: a hexagon with the number 23 inside.
+
+Tap 8 ways output
+(tap loss 23 dB)
+
+Tap 8 ways output (tap loss 26 dB) symbol: a hexagon with the number 26 inside.
+
+Tap 8 ways output
+(tap loss 26 dB)
+
+Tap 8 ways output (tap loss 29 dB) symbol: a hexagon with the number 29 inside.
+
+Tap 8 ways output
+(tap loss 29 dB)
+
+Terminator symbol: a triangle pointing to the right.
+
+Terminator
+
+
+
+CIU (Customer Interface Unit) symbol: a triangle with a square inside.
+
+CIU
+(Customer Interface Unit)
+
+T0605090-00
+
+# **SERIES OF ITU-T RECOMMENDATIONS**
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series B | Means of expression: definitions, symbols, classification |
+| Series C | General telecommunication statistics |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | TMN and network maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks and open system communications |
+| Series Y | Global information infrastructure and Internet protocol aspects |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.62-200409-I_PDF-E/raw.md b/marked/L/T-REC-L.62-200409-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..b9c3d8e177c7cf676428dea475ddb3137dfe97ff
--- /dev/null
+++ b/marked/L/T-REC-L.62-200409-I_PDF-E/raw.md
@@ -0,0 +1,473 @@
+
+
+
+
+ITU logo: A globe with a red lightning bolt and the letters ITU.
+
+INTERNATIONAL TELECOMMUNICATION UNION
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.62**
+
+(09/2004)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Practical aspects of unbundling services by
+multiple operators in copper access networks**
+
+ITU-T Recommendation L.62
+
+---
+
+
+
+# **Practical aspects of unbundling services by multiple operators in copper access networks**
+
+## **Summary**
+
+In many countries, Other Licensed Operators (OLOs) are allowed to compete with the incumbent operator. This creates an environment where a company has to install, operate and maintain its network bearing in mind that other networks exist right beside it, or even at the same location. In a number of countries, it is also determined that the operators should share some parts of the network with OLOs, in a transparent process to the users. This is called Unbundling of Network Elements or, in short, unbundling, and is a very complex task. Some new issues have to be taken into account to allow the accommodation of those operators sharing the same location to do so without problems. To guarantee an environment where operators interact but do not affect the Quality of Service provided by other operators, legal, regulatory and administrative statements must be followed by the correct technical solutions, which assure the network integrity, easy use of equipment and access to security. This Recommendation is intended to provide the guidelines to achieve these targets for the local loop in copper networks.
+
+## **Source**
+
+ITU-T Recommendation L.62 was approved on 6 September 2004 by ITU-T Study Group 6 (2001-2004) under the ITU-T Recommendation A.8 procedure.
+
+## **Keywords**
+
+Copper cable, ISDN, local loop, network element, shared network, unbundling, xDSL.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database.
+
+© ITU 2005
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | Page |
+|---------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 4 Abbreviations..... | 3 |
+| 5 Topologies ..... | 4 |
+| 5.1 Indoor ..... | 4 |
+| 5.2 Outdoor..... | 5 |
+| 6 Issues related to unbundling ..... | 5 |
+| 6.1 Interfacing operators on the MDF ..... | 5 |
+| 6.2 Interfacing operators on cabinets or closures ..... | 6 |
+| 6.3 Interfacing operators on aerial installations ..... | 6 |
+| 6.4 Interfacing operators on buried installations ..... | 6 |
+| 6.5 Interfacing operators in the manhole..... | 6 |
+| 6.6 Interfacing operators on the customer premises..... | 6 |
+| 6.7 Cable frequency spectrum management plan..... | 7 |
+| 6.8 Installation and maintenance ..... | 7 |
+| 7 Issues related to co-location ..... | 7 |
+| 7.1 Typical co-location inside MDF..... | 7 |
+| 7.2 Virtual co-location inside MDF..... | 8 |
+| 7.3 Co-location outside MDF ..... | 8 |
+| 8 Shared sub-loops..... | 9 |
+
+# **Introduction**
+
+Network elements can be unbundled in a number of ways which are described in this Recommendation. Co-location is also described, as it is intrinsically related to unbundling.
+
+Crucial aspects must be foreseen, e.g., the evolution of the optical access network, which reduces the copper network, getting closer to the customer premises. It may be difficult to change the network topology maintaining services already provided by OLOs in the same network element.
+
+It must be noted that when multiple services are provided over the same network element, each service must not affect the Quality of Service provided by other operators and shall comply with the Recommendations applicable for each service when provided alone. Also, a service must not interfere with other services in use, or which are planned to be used, in a network element.
+
+# Practical aspects of unbundling services by multiple operators in copper access networks
+
+# 1 Scope
+
+This Recommendation relates to the technical aspects of copper local loop unbundling which, it should be noted are subject to national regulations. Although a number of network elements can be defined, this Recommendation focuses specifically on the copper local loop because it is the most prevalent worldwide.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- ITU-T Recommendation K.58 (2003), *EMC, resistibility and safety requirements and procedures for co-located telecommunication installations.*
+- ITU-T Recommendation K.59 (2003), *EMC, resistibility and safety requirements and procedures for connection to unbundled cables.*
+- ITU-T Recommendation L.19 (2003), *Multi-pair copper network cable supporting shared multiple services such as POTS, ISDN and xDSL.*
+
+# 3 Definitions
+
+This Recommendation defines the following terms.
+
+For better understanding of the terms, the main types of unbundling of the local loop are outlined in Figure 1 and described below. See abbreviations on the next item.
+
+
+
+The diagram shows the internal structure of an Incumbent's Central Office (ICO) and its connections to external networks. On the left, three 'Local loop' lines connect to an 'M D F' (Main Distribution Frame). From the M D F, the lines pass through 'Splitters' which divide the signals into 'Higher band' (for data) and 'Lower band' (for voice). The 'Higher band' signals are connected to two 'DSLAM' units: one labeled 'DSLAM (OLO)' located within a 'Collocation area', and another labeled 'DSLAM (incumbent)'. The 'Lower band' signals are connected to the 'Incumbent network'. The 'DSLAM (OLO)' is connected to the 'OLO network' via a 'Bit stream' connection. The 'Incumbent network' is also connected to the 'OLO network' via 'Line sharing'. The entire setup is contained within the 'INCUMBENT'S CENTRAL OFFICE' boundary. A label 'L.062\_F01' is present in the bottom right corner.
+
+Diagram illustrating typical types of unbundled network elements within an Incumbent's Central Office (ICO).
+
+Figure 1/L.62 – Typical types of unbundled network elements
+
+**3.1 full unbundling:** OLO has direct access to the twisted copper pair and can use the pair to provide any service allowed (xDSL, voice), without interfering with other services provided in the same cable, usually associated with co-location of OLO's equipment.
+
+**3.2 line sharing:** Voice service (POTS, PSTN) and data transmission services (xDSL, ISDN) are provided using the same copper pair. Voice is provided in the lower frequency band and data transmission in the higher frequency band. Both operators must physically access the pair, and the OLO's equipment is usually housed in a co-location area inside the incumbent's central office building. Splitters have to be installed, both in the customer's premises and in the central office, to guide the signals suitably to the computer and to the telephone terminal, and to their correspondent networks.
+
+**3.3 bitstream:** Actually, this is not unbundling, but a higher layer service, with less physical contact between the incumbent and the OLO. In this Recommendation, this term includes the wholesale services provided by the incumbent to other operators that, otherwise, would not have access to their customers. Typically, the incumbent operator installs and operates the network from the customer premises to the DSLAM, providing the OLO with a bundle of channels (usually STM-1) usually associated with a transportation service (back haul) to the nearest OLO's PoP.
+
+**3.4 co-location:** An OLO may want to (or may be obliged to) rent space in the incumbent's central office to install its own equipment. Figure 1 shows a typical co-location area inside the CO, with the OLO's DSLAM installed on it. Due to an eventual lack of suitable space, there are some different kinds of co-location arrangements. When some OLOs want to (or may be obliged to) use the same room (or cabinet), there is a "shared co-location". A "virtual co-location" takes place when the DSLAM belongs to the OLO, but is installed and operated by the incumbent. Also, equipment
+
+may be housed outside the incumbent's building (remote co-location), in another building or in containers located in parking lots, for example. Another special situation, described in 3.5, occurs when an outdoor remote DSLAM is needed.
+
+**3.5 outdoor remote DSLAM:** This is the toughest situation, requiring critical technical solutions. When a network has remote concentration (or switching) elements in cabinets along the copper loops, it may be necessary to connect those elements to the OLO's network. Usually there is no space for co-location and the elements are in an aggressive environment. This connection can be a very challenging task, as the equipments of both operators may have to be able to accept external tie cables and/or have space inside to install the OLO's DSLAM. Other solutions may include connection of the incumbent's cabinet to the OLO's cabinet, compatible printed circuit cards inserted in the incumbent's remote equipment, and the transport of the signals by the incumbent to the OLO's nearest PoP. The physical access is an important issue that has to have a convenient solution, because of security matters. Special attention is needed when the insertion of signals is allowed at some point along the cable between the central office and the customer's premises. Such signals may interfere in the other services already provided on the same cable since they can be stronger than the others at the insertion point.
+
+**3.6 sub-loop:** There are special circumstances, usually in long copper loops, where parts of the local loop are rented separately from each other. The individual sub-loop elements usually available are feeders, distribution and concentration elements. Problems and solutions are similar to those listed for the outdoor remote DSLAM.
+
+# 4 Abbreviations
+
+This Recommendation uses the following abbreviations:1
+
+| | |
+|-------|----------------------------------------------------------------------|
+| ADSL | Asymmetric Digital Subscriber Line |
+| CO | Central Office |
+| DSLAM | Digital Subscriber Line Access Multiplexer |
+| EMC | Electromagnetic Compatibility |
+| EMI | Electromagnetic Interference |
+| HDF | Handover Distribution Frame |
+| HDSL | High bit rate Digital Subscriber Line |
+| ISDN | Integrated Services Digital Network |
+| LLU | Local Loop Unbundling also called Unbundling of the Local Loop (ULL) |
+| MDF | Main Distribution Frame |
+| NE | Network Element |
+| NTP | Network Termination Point |
+| OLO | Other Licensed Operator |
+| PoP | Point of Presence |
+| POTS | Plain Old Telephone Service |
+| PSTN | Public Switched Telephone Network |
+| SDSL | Symmetric Digital Subscriber Line |
+
+---
+
+1 Extracted from ITU's abbreviations database ().
+
+| | |
+|-------|------------------------------------------------------|
+| SHDSL | Single pair High speed Digital Subscriber Line |
+| SSDSL | Synchronized Symmetrical Digital Subscriber Line |
+| STM | Synchronous Transport Module |
+| UADSL | Universal Asymmetric Digital Subscriber Line |
+| UNE | Unbundling of Network Elements |
+| VDSL | Very high-speed Digital Subscriber Line |
+| xDSL | Any of the various types of Digital Subscriber Lines |
+
+# 5 Topologies
+
+The connection between incumbent and OLO equipments can be done at points that depend on the topology of the network. The following items describe some recommended configurations.
+
+## 5.1 Indoor
+
+
+
+Diagram of a typical DSL network and indoor connection points. On the left, a 'DSL modem' is connected to a 'Splitter'. Point (a) is the connection between the modem and the splitter, and point (b) is the output of the splitter. A line connects point (b) to point (c) at the 'MDF' (Main Distribution Frame). From the MDF, the line goes to another 'Splitter'. Point (d) is the output of this splitter, which connects to a 'DSLAM'. Point (e) is a connection point on the line between the MDF and the 'Local switch'. Point (f) is the output of the 'DSLAM' which connects to a 'Router'. The diagram is labeled 'L.062\_F02'.
+
+"X" indicates connection points.
+
+- (1) Connection at MDF corresponding to (c), (e) as shown in the figure above.
+- (2) Splitter output corresponding to (d) as shown in the figure above.
+- (3) Output port of DSLAM corresponding to (f) as shown in the figure above.
+
+**Figure 2/L.62 – Typical DSL network and indoor connection points**
+
+## 5.2 Outdoor
+
+
+
+Diagram of a typical DSL network and outdoor connection points. A 'Central office' is connected to a 'Cable distribution box/manhole'. From this box, a line goes to an 'Other location' and another line goes to a 'Distribution board'. The 'Distribution board' is connected to a 'Floor distribution board', which in turn connects to three telephone icons. Arrows with the text 'Possibility of sub-loop unbundling' point to the connections between the 'Cable distribution box/manhole' and the 'Other location', and between the 'Cable distribution box/manhole' and the 'Distribution board'. The label 'L.062\_F03' is at the bottom right.
+
+Figure 3/L.62 – Typical DSL network and outdoor connection points
+
+# 6 Issues related to unbundling
+
+Specific rules must be agreed upon with all operators that share a network element. There should be security rules related to physical access, fire safety, electrical compatibility, EMC/EMI, etc.
+
+Information about that part of the network should be available, to avoid problems like interruptions, interferences, etc.
+
+## 6.1 Interfacing operators on the MDF
+
+
+
+Diagram showing two typical MDF connection points: 'Full access' and 'Shared access'. Both diagrams show a 'Local loop' and an 'Unbundled local loop' entering an 'Incumbent MDF'. In the 'Full access' diagram, the 'Unbundled local loop' is connected via a 'jumper' to a 'DF' (Distribution Frame), which is then connected via an 'Internal cable' to an 'HDF' (High Density Frame), which in turn connects to 'OLO equipment' (part of an 'OLO module'). The 'Local loop' connects directly to a 'Local exchange'. In the 'Shared access' diagram, the 'Unbundled local loop' is connected to a 'splitter', which then connects to the 'DF' and 'HDF' leading to 'OLO equipment'. The 'Local loop' also connects to the 'Local exchange'. The label 'L.062\_F04' is at the bottom right.
+
+Figure 4/L.62 – Typical MDF connection points
+
+## 6.2 Interfacing operators on cabinets or closures
+
+
+
+The diagram illustrates two typical cabinet and closure connection point configurations:
+
+- Full access:** A cabinet containing a Local exchange, Incumbent MDF, and OLO equipment. The Local exchange is connected to an MDF, which is connected to a DF. The DF is connected to an HDF, which is connected to the OLO equipment. An external cable connects the HDF to the OLO equipment. A jumper connects the DF to the Incumbent MDF.
+- Shared access:** A cabinet containing a Local exchange, Incumbent MDF, and OLO equipment. The Local exchange is connected to an MDF, which is connected to a DF. The DF is connected to a splitter, which is connected to the Incumbent MDF. The DF is also connected to an HDF, which is connected to the OLO equipment. An external cable connects the HDF to the OLO equipment.
+
+L.062\_F05
+
+Diagram showing two cabinet configurations: 'Full access' and 'Shared access'. Both show connections between a Local exchange, OLO equipment, and Incumbent MDF via MDF, DF, and HDF components. The 'Full access' configuration shows direct connections, while the 'Shared access' configuration includes a splitter.
+
+Figure 5/L.62 – Typical cabinets and closures connection points
+
+## 6.3 Interfacing operators on aerial installations
+
+This infrequent configuration needs further study.
+
+## 6.4 Interfacing operators on buried installations
+
+This infrequent configuration needs further study.
+
+## 6.5 Interfacing operators in the manhole
+
+
+
+The diagram illustrates a typical manhole connection point configuration:
+
+- A Central office contains OLO, MDF, Incumbent, and MDF components. The bottom MDF is connected to a Common cable.
+- The Common cable connects to a Joint in a Manhole.
+- The Joint connects to the Incumbent network and the OLO network.
+
+L.062\_F06
+
+Diagram showing a manhole connection point. A Central office contains OLO, MDF, Incumbent, and MDF components. A Common cable connects the bottom MDF to a Joint in a Manhole. The Joint connects to the Incumbent network and the OLO network.
+
+Figure 6/L.62 – Typical manhole connection points
+
+## 6.6 Interfacing operators on the customer premises
+
+This subject is for further study.
+
+## 6.7 Cable frequency spectrum management plan
+
+The occupation of the frequency spectrum must be determined before the shared services start, to avoid interferences. A spectrum management policy must be implemented and respected by all operators involved. Some services, e.g., voice, may have precedence over others.
+
+Factors that must be taken into account include: cable characteristics related to data transmission; connector characteristics; copper pair pre-qualification and conditioning; services allowed simultaneously and their protocols; maximum number of pairs used for each service in a cable; selection of pairs as a function of different services, etc.
+
+## 6.8 Installation and maintenance
+
+The involved operators must agree upon the installation and maintenance procedures, including action flowchart; time-limits and responsibilities; network integrity assurance; implementation of new technologies and topologies; proceedings to solve conflicts, etc.
+
+# 7 Issues related to co-location
+
+Specific rules must be agreed upon with all operators that co-locate equipments. There should be security rules related to physical access, fire safety, electrical compatibility, EMC/EMI, etc.
+
+## 7.1 Typical co-location inside MDF
+
+
+
+The diagram illustrates the typical co-location inside a Main Distribution Frame (MDF). On the left, 'Customer premises' are connected via a 'Fibre optic cable' to a 'Transmission equipments room' within the 'CENTRAL OFFICE'. Inside the central office, the fibre optic cable connects to two 'FTF' (Fibre optic Termination Frame) units, which are then connected to 'T.I. equipments' and a 'T.I.' (Transmission Interface) unit. A 'Numeric channel' is also shown within the central office, connected to a 'Copper cable'. The 'T.I.' unit is connected to an 'A2' point. From 'A2', a line goes to an 'OLO vault' (point 'D'), and another line goes to an 'A3' point. At 'A3', the path splits: one goes to an 'OLO shared shelter' (point 'A'), and the other goes to a 'T.I. connection vault' (point 'C'). Inside the 'OLO shared shelter', the path goes through an 'FTF' unit to 'OLO equipments' and an 'OLO' unit. From the 'OLO' unit, the path goes to a 'Main manhole' (point 'B'). The 'T.I. connection vault' (point 'C') is also connected to the 'Main manhole' (point 'B'). A legend at the bottom left defines the abbreviations: FTF = Fibre optic Termination Frame, MDF = Main Distribution Frame, OLO = Other Licensed Operator, TDF = Transmission Distribution Frame. The diagram is labeled 'L.062\_F07' at the bottom right.
+
+Legend
+FTF = Fibre optic Termination Frame
+MDF = Main Distribution Frame
+OLO = Other Licensed Operator
+TDF = Transmission Distribution Frame
+
+Diagram of typical co-location inside MDF showing connections between Customer premises, Central Office, and OLO shared shelter.
+
+Figure 7/L.62 – Typical co-location inside MDF
+
+## 7.2 Virtual co-location inside MDF
+
+
+
+CENTRAL OFFICE
+
+Transmission equipments room
+
+Customer premises
+
+FTF
+
+A1
+
+T.I. equipments
+
+T.I. TDF
+
+FTF for OLO
+
+OLO equipments (ADSL)
+
+FTF for OLO
+
+A2
+
+OLO TDF\*
+
+A
+
+T.I. MDF
+
+Copper cable
+
+OLO vault
+
+T.I. connection vault
+
+Main manhole
+
+D
+
+C
+
+L.062\_F08
+
+Legend
+
+FTF = Fibre optic Termination Frame
+
+MDF = Main Distribution Frame
+
+OLO = Other Licensed Operator
+
+TDF = Transmission Distribution Frame
+
+\* TDF OLO and FTF OLO, normally, coincide with the existing T.I. FTF
+
+Diagram of typical virtual co-location inside MDF showing connections between Customer premises, Transmission equipments room (with FTF, T.I. equipments, T.I. TDF, OLO equipments (ADSL), OLO TDF\*, and T.I. MDF), OLO vault, T.I. connection vault, and Main manhole via Copper cable.
+
+Figure 8/L.62 – Typical virtual co-location inside MDF
+
+## 7.3 Co-location outside MDF
+
+
+
+CENTRAL OFFICE
+
+Transmission equipments room
+
+Customer premises
+
+FTF
+
+A1
+
+T.I. equipments
+
+T.I. TDF
+
+A2
+
+A3
+
+OLO shared shelter
+
+OLO equipments
+
+FTF
+
+OLO TDF
+
+A
+
+T.I. MDF
+
+Fibre optic cable
+
+Numeric channel
+
+Copper cable
+
+OLO vault
+
+T.I. connection vault
+
+Main manhole
+
+D
+
+C
+
+L.062\_F09
+
+Legend
+
+FTF = Fibre optic Termination Frame
+
+MDF = Main Distribution Frame
+
+OLO = Other Licensed Operator
+
+TDF = Transmission Distribution Frame
+
+Diagram of typical co-location outside MDF showing connections between Customer premises, Transmission equipments room (with FTF, T.I. equipments, T.I. TDF, and T.I. MDF), OLO shared shelter (with OLO equipments, FTF, and OLO TDF), OLO vault, T.I. connection vault, and Main manhole via Fibre optic cable, Numeric channel, and Copper cable.
+
+Figure 9/L.62 – Typical co-location outside MDF
+
+# 8 Shared sub-loops
+
+Specific rules must be agreed upon with all operators that share sub-loops. There should be security rules related to physical access, fire safety, electrical compatibility, EMC/EMI, etc.
+
+Special attention must be given to external tie cables and the related hardware to be used at the operators interface point, e.g., splices, connectors, etc.
+
+
+
+The diagram illustrates a typical shared sub-loop configuration. At the top, an 'End user site' is connected via a 'Drop' to a 'Terminal or pedestal'. From the 'Terminal or pedestal', a 'Distribution cable' leads to 'Distribution facilities', which then connect to the 'Incumbents operator CCC'. Below the 'Terminal or pedestal', an 'OLO's feeder' connects to an 'OLO's interconnection cabinet', which is followed by an 'Interface point'. From the 'Interface point', an 'Interconnect cable Tie cable' connects to the 'Incumbents operator CCC'. The 'Incumbents operator CCC' is also connected to 'Incumbents operator Feeder facilities', which in turn connect to the 'Incumbents Central office'. A small 'X' is marked on the line between the 'Interface point' and the 'Incumbents operator CCC'. The label 'L.062\_F10' is located in the bottom right corner of the diagram area.
+
+Diagram of a typical shared sub-loop showing connections between an end user site, terminal/pedestal, OLO's feeder, OLO's interconnection cabinet, interface point, incumbents operator CCC, incumbents operator feeder facilities, and incumbents central office.
+
+Figure 10/L.62 – Typical shared sub-loop
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | TMN and network maintenance: international transmission systems, telephone circuits, telegraphy, facsimile and leased circuits |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks and open system communications |
+| Series Y | Global information infrastructure, Internet protocol aspects and Next Generation Networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/0cc86fe8fc37b0edc9581f2af9459a52_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/0cc86fe8fc37b0edc9581f2af9459a52_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cca5e186363a7b3e38f4c5193bae9bbfb3fe300b
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/0cc86fe8fc37b0edc9581f2af9459a52_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1c63b7aa71c3b9fff490eedd06cff7ec916e1d42018269c4d706cafe0e3297b8
+size 20361
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/0dd5ee731e9d7e34e498b5c926110773_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/0dd5ee731e9d7e34e498b5c926110773_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7558add78ad0a886fb2c2700e46f144ef3662fd5
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/0dd5ee731e9d7e34e498b5c926110773_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:864a54ec71451f4a123dbc84c024deeb343a91c0fbc0d842ebe64c5413a9001b
+size 79506
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/0f2a1e4a7b12fe5b8749882ecd636f5c_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/0f2a1e4a7b12fe5b8749882ecd636f5c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ee74b50ab11cff4d350bd3ac98d2a111dd98069c
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/0f2a1e4a7b12fe5b8749882ecd636f5c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2d531cf98ef8d067152b044db3e1fe561a827e6fd39c0d1d7abaa437f4db6cdb
+size 89700
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/6ed175c791b5e156d9c98a8dbcc3318c_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/6ed175c791b5e156d9c98a8dbcc3318c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..051421652f52626fa3003bed6eef194c2f0bf8f4
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/6ed175c791b5e156d9c98a8dbcc3318c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4e73ffff0a3e5ea56697a72c86ba5ff7070dd484950e7f8ba5879a72b105e02b
+size 8282
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/e3b8510f6a2194e250205ab7bc38076d_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/e3b8510f6a2194e250205ab7bc38076d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..915eb95b710ab241be922f656c2167b4adfc5431
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/e3b8510f6a2194e250205ab7bc38076d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bbea0aa1d02e78b7840d9c520ecbee90afd46dcd60800400c1ec6deb11faa35e
+size 51452
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/ea691955a06abea9018f39baa5ebe46d_img.jpg b/marked/L/T-REC-L.63-200410-I_PDF-E/ea691955a06abea9018f39baa5ebe46d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f12a85cafabb7e31a9be2683ba9cac1d4b35a43f
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/ea691955a06abea9018f39baa5ebe46d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a3919f067ad8294d00b015d6b1d5612be4d9cdcdd874e04763f52edc0925608e
+size 53791
diff --git a/marked/L/T-REC-L.63-200410-I_PDF-E/raw.md b/marked/L/T-REC-L.63-200410-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..e791700ae052d9a62494ea320c71d5dafe7d40c9
--- /dev/null
+++ b/marked/L/T-REC-L.63-200410-I_PDF-E/raw.md
@@ -0,0 +1,366 @@
+
+
+International Telecommunication Union
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.63**
+
+(10/2004)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS
+OF OUTSIDE PLANT
+
+# --- **Safety practice for outdoor installations**
+
+ITU-T Recommendation L.63
+
+
+
+The logo of the International Telecommunication Union (ITU) features a globe with a red lightning bolt striking it, symbolizing telecommunications. To the right of the globe, the text "International Telecommunication Union" is written in blue, with "ITU" in a larger, bold font above it.
+
+ITU logo
+
+
+
+# **ITU-T Recommendation L.63**
+
+# **Safety practice for outdoor installations**
+
+## **Summary**
+
+This Recommendation has the objective to establish safety practices for personnel and operations to provide protection against fire in outdoor telecommunications installations and in shared infrastructures.
+
+## **Source**
+
+ITU-T Recommendation L.63 was approved on 7 October 2004 by ITU-T Study Group 6 (2001-2004) under the ITU-T Recommendation A.8 procedure.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2008
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+# CONTENTS
+
+| | Page |
+|----------------------------------------------------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Construction infrastructure ..... | 1 |
+| 3.1 Duct systems..... | 2 |
+| 3.2 Cable tunnels ..... | 2 |
+| 3.3 Manholes ..... | 2 |
+| 3.4 Sewage infrastructure installations..... | 3 |
+| 4 Outside plant network..... | 3 |
+| 4.1 Aerial network..... | 3 |
+| 4.2 Buried network ..... | 3 |
+| 5 Outside plant equipment..... | 4 |
+| 6 Shared infrastructure..... | 4 |
+| Appendix I – Ukraine experience – Fire safety in the duct system ..... | 5 |
+| I.1 Duct system of Ukraine ..... | 5 |
+| I.2 Fire safety in manholes, collectors and tunnels..... | 8 |
+| Appendix II – Brazilian experience – Safety of personnel for installation in infrastructures of power lines distribution..... | 9 |
+
+
+
+## ITU-T Recommendation L.63
+
+## Safety practice for outdoor installations
+
+# 1 Scope
+
+The objective of this Recommendation is to provide guidance to administrations on safety practice for personnel and fire protection for outdoors telecommunications installations such as duct systems, manholes, tunnels, aerial, underground and buried networks, subscribers, equipments for outside plant, and networks in sewage infrastructures.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- ITU-T Recommendation K.11 (1993), *Principles of protection against overvoltages and overcurrents*.
+- ITU-T Recommendation K.13 (1988), *Induced voltages in cables with plastic-insulated conductors*.
+- ITU-T Recommendation K.25 (2000), *Protection of optical fibre cables*.
+- ITU-T Recommendation K.26 (1988), *Protection of telecommunication lines against harmful effects from electric power and electrified railway lines*.
+- ITU-T Recommendation K.51 (2000), *Safety criteria for telecommunication equipment*.
+- ITU-T Recommendation K.58 (2003), *EMC, resistibility and safety requirements and procedures for co-located telecommunication installations*.
+- ITU-T Recommendation K.59 (2003), *EMC, resistibility and safety requirements and procedures for connection to unbundled cables*.
+- ITU-T Recommendation K.64 (2004), *Safe working practices for outside equipment installed in particular environments*.
+- ITU-T Recommendation L.20 (1996), *Creation of a fire security code for telecommunication facilities*.
+- ITU-T Recommendation L.21 (1996), *Fire detection and alarm systems, detector and sounder devices*.
+- ITU-T Recommendation L.22 (1996), *Fire protection*.
+
+# 3 Construction infrastructure
+
+For the purpose of this Recommendation, the construction infrastructure is considered to be any of the following outdoor installations associated with the outside plant.
+
+## **3.1 Duct systems**
+
+In selecting permanent locations for underground structures, future road developments and plans of others utilities should be considered.
+
+Manholes should be located away from road intersections, for safety of workers and the public.
+
+Use bottom ducts first, use outside ducts first.
+
+In the construction or maintenance of duct lines, the projects must first be analysed for compliance with all the security procedures demanded by the administration for workmanship, and full planning information along the route to be constructed or renewed.
+
+Complete design plans should be obtained of all the existing installations, including topological and soil information; in addition, safety and signalling supplies and standard shoring and mechanical equipment should be made available.
+
+In the case of existing water, fuel, gas or energy distribution systems, the required safety procedures must be observed, in particular the depths demanded for each administration.
+
+The use of ducts and spacers constructed of polyvinyl chloride (PVC) or polyethylene (PE) and, if possible, concrete is recommended.
+
+When conducting work on any installation, safety procedures must be followed regarding:
+
+- trench depth;
+- local conditions;
+- construction site signalling.
+
+## **3.2 Cable tunnels**
+
+Normally cable tunnels are used inside telephone exchange buildings. Safety systems are normally fitted to guard against smoke and fire; they are controlled by detectors and alarms (visible and/or audible), and are complemented by fire extinguishers, gas detectors that are installed in the tunnel and ducts. These systems should be properly monitored.
+
+Detection systems that are electrically powered should use low voltages, to prevent the risk of explosion, mainly associated with the risk of gases in the tunnels.
+
+All safety equipment must be routinely inspected. In the case of tunnels where there exists shared infrastructure, each company should label its own installations; the appropriate separation distances should be respected.
+
+In the case of tunnels where cables are to be located next to installations carrying gas or gasoline, or sharing infrastructure, it is recommended that alarm devices be used to monitor for the presence of smoke, gas or gasoline.
+
+In cable tunnels, cables should be filled, and grounded using the same point of ground as the central office. All underground splices must be filled, and bonded to the vault ground.
+
+## **3.3 Manholes**
+
+When opening manholes, the following considerations are recommended:
+
+- check for the presence of water, gasoline, fuel, etc. when opening the manhole;
+- perform basic gas detection tests;
+- wait a minimum of 10 minutes before entering;
+- keep gas detectors operational, if possible, while working inside;
+- keep an audible alarm system activated;
+
+- use only equipment with low voltage and low current, if possible;
+- avoid remaining inside the enclosure for protracted periods;
+- always keep a means of rapid exit (stairs) from the chambers available;
+- never work alone;
+- use an alarm system with external signalling;
+- in rainy weather, take measures to prevent water entering the enclosure;
+- if mains power is used, overcurrent and overvoltage protection is required;
+- cable pressure meters shall be fitted at the entrances to all manholes.
+
+## **3.4 Sewage infrastructure installations**
+
+In sewage installations, cables and components must be manufactured so as to protect workers against the risk of contamination.
+
+The rules established by the health and environmental administrations to this effect must be observed.
+
+All workers must be briefed by health and environment specialists.
+
+Further study is required into the effects of the harsh environment present in sewage installations.
+
+# **4 Outside plant network**
+
+## **4.1 Aerial network**
+
+Aerial telecommunication cables should incorporate the following fire safety measures:
+
+- Cable sheaths should be manufactured of a material that is not flame propagating and has low smoke and zero halogen emissions, for use in environments of great agglomeration of people, such as subway or train stations.
+- When designing the installation of the cables or wires, the distance of separation from energy networks and the maximum dip of the cable or wire in relation to the ground must be respected.
+- The ground points must be independent of electrical energy network.
+- Verify the levels of voltage that may be present.
+- It is NOT recommended to plan or install equipment that needs grounding on poles where there are energy network ground points.
+
+## **4.2 Buried network**
+
+The minimum depth of buried cables is typically 1.20 m.
+
+Buried cables may be protected against lightning strikes by the installation of a copper conductor or steel wire of 6 mm2 , installed approximately 600 mm above the cable. An indication band (warning tape) should be buried 200 mm above the cable.
+
+Along the installation route, the presence of buried cables can be indicated with signs. For better protection, splices must be located where they will be readily accessible.
+
+This type of installation requires an effective monitoring system with a view to assisting in the localization of damages.
+
+# **5 Outside plant equipment**
+
+Some equipment is installed in outside plant units, such as subscriber multiplex, DSLAMs, amplifiers for CATV, subscriber equipment, HDSL modems, optical distribution frames, main distribution frames, and SDH MUXes. They should be protected by remote safety and fire control systems.
+
+# **6 Shared infrastructure**
+
+In the case of shared infrastructure, fire-fighting and safety systems need to be carefully planned so as to avoid mutual interference.
+
+The use of differentiated protection makes it possible for each operator's worker to work in safety, and provide the appropriate level of protection in each case.
+
+A minimum distance between infrastructures must be observed.
+
+# Appendix I
+
+## Ukraine experience
+
+## Fire safety in the duct system
+
+### Introduction
+
+This appendix contains information about the duct system in Ukraine, as well as accepted fire safety measures in the duct system.
+
+## I.1 Duct system of Ukraine
+
+The communication duct system consists of buried ducts and different types of inspection facilities (e.g., manholes, collectors, tunnels and cable chambers).
+
+The buried ducts contain bundles of conduits or multihole blocks. The maximum capacity of the duct system is 48 or 60 conduits. The distance between inspection pits is 150 m.
+
+The duct materials are concrete, asbestos, polyethylene, steel and ceramic (Figure I.1).
+
+
+
+Figure I.1 shows four diagrams of different duct types: a) concrete conduits, b) asbestos duct, c) polyethylene ducts, and d) steel ducts. Diagram (a) shows three rectangular concrete blocks with dimensions 1000mm length, 150mm height, and widths of 150mm, 275mm, and 400mm, each containing one, two, or three 100mm diameter holes. Diagram (b) shows a single asbestos duct with a 100mm diameter and a length of 3 to 4 meters. Diagram (c) shows polyethylene ducts with lengths of 12m, 10m, and 30-200m, and outside diameters of 110mm, 110mm, and 83mm. Diagram (d) shows steel ducts with a length of 4000-15000mm, an inside diameter of 96mm (90mm), and a 90-degree bend with dimensions 1100mm, 450mm (650mm), and 700mm.
+
+**Figure I.1 – Different types of duct (concrete, asbestos, polyethylene, steel)**
+
+The oldest design uses concrete conduits. The rectangular blocks, one metre in length, have one, two or three holes (of 100 mm diameter). The separate blocks are placed end to end and joined by means of mortar.
+
+The most widespread type of design uses asbestos ducts. The separate ducts, three to six metres in length, have an inside diameter of 100 mm. They are joined by means of mortar or collar joints.
+
+However, the use of asbestos ducts is dangerous for the health of construction and maintenance personnel. Therefore, it is advised not to use this kind of material in the construction of new duct systems.
+
+Recently, polyethylene ducts have come into use in big cities. The separate HDPE ducts have a length of 8 to 12 m, and an outside diameter of 110 mm. The ducts are joined by welding or using collar joints.
+
+Short lengths of steel tube are used where ducts enter buildings. They are also used in free-flowing ground. The ducts have a length of 4 to 12 m and an inside diameter of 90 to 96 mm. Steel-to-steel joints are welded, while joints with asbestos ducts are made by means of mortar.
+
+Ceramic ducts are used very rarely, being confined to acidic soils. Duct sections are 0.9 m long and have an inside diameter of 100 mm.
+
+The main type of inspection facility is the manhole. Manholes may be of brick or reinforced concrete construction; some are manufactured in one piece. Three types of manholes are used: in-line, angle, and splitter (Figure I.2).
+
+
+
+The diagram illustrates three common configurations for manholes in a duct system. The first manhole on the left is an 'in-line' type, shown as a hexagonal prism with a hatch on its top face. It has an 'overlap' section at the top, an 'upper wall', a 'lower wall', and a 'bottom'. Ducts enter and exit from the sides. The middle manhole is an 'angle' type, also hexagonal, but with a more complex internal structure. It features 'cable brackets' and a 'closure' mechanism. Ducts enter and exit at different angles. The third manhole on the right is a 'splitter' type, which is a hexagonal prism with a hatch on top and ducts entering and exiting from the sides. Labels with leader lines identify the 'hatch', 'overlap', 'upper wall', 'lower wall', 'bottom', 'cable brackets', 'closure', and 'blocks of ducts'. The code 'L.063\_F1.2' is located in the bottom right corner.
+
+Figure I.2 – Building blocks of a communication duct. The diagram shows three types of manholes: in-line, angle, and splitter. The in-line manhole is a hexagonal structure with a hatch on top, an overlap, an upper wall, a lower wall, and a bottom. The angle manhole is a hexagonal structure with cable brackets and a closure. The splitter manhole is a hexagonal structure with a hatch on top. Labels include: hatch, overlap, upper wall, lower wall, bottom, cable brackets, closure, blocks of ducts, and L.063\_F1.2.
+
+**Figure I.2 – Building blocks of a communication duct**
+
+The most widespread design is a reinforced concrete manhole consisting of the lower wall ring with a base, and the upper wall ring with overlap.
+
+Brick manholes are less reliable, being more permeable for gases and water. On the other hand, brick construction can be used to build a manhole of any shape and dimensions desired. This is important where the duct system is being built near utilities or buildings.
+
+Cast-iron hatches provide for access to the manhole (Figure I.3). The inlet diameter is 600 mm. The hatch consists of a cast frame and upper cover, and a steel lower cover. The lower cover has a fitting for a lock. Both covers have fittings to allow a check for gas to be made without opening either cover. The mass of the hatch is 138 kg (heavy type) or 82 kg (light type).
+
+
+
+Figure I.3: Cast hatch. The diagram shows a cross-sectional view and a top-down view of a circular cast hatch. The cross-section labels include 'frame', 'upper cover', 'lower cover', and 'fitting for lock'. Dimensions for the cross-section are: 722 (outer diameter of upper cover), 666 (inner diameter of upper cover), 110 (height of upper cover), 600 (inner diameter of lower cover), and 850 (outer diameter of lower cover). The top-down view shows concentric circles and the letters 'ГТС' in the center. The label 'L.063\_FI.3' is at the bottom right.
+
+**Figure I.3 – Cast hatch**
+
+Inside the manholes, cables are positioned on brackets (Figure I.4).
+
+
+
+Figure I.4: Cable brackets. The diagram shows a side view and a top-down view of a cable bracket. The side view dimensions are: 40 (width of the first bracket), 104 (spacing between brackets), 104 (spacing between brackets), 48 (width of the last bracket), and 100 (height of the bracket). The top-down view shows the profile of the brackets. The label 'L.063\_FI.4' is at the bottom right.
+
+**Figure I.4 – Cable brackets**
+
+The collector (Figure I.5) is a shared underground enclosure for components of different services (communication cables, electric power cables, hot-water pipes, steam conduits, pneumatic systems, sanitary drain pipelines and low-pressure gas pipelines).
+
+Collectors are situated 1-1.2 m below ground. The inside dimensions are: width 1.7-2.7 m, height 1.8-3.0 m.
+
+
+
+A cross-sectional diagram of an underground collector. The interior width is labeled as 1700 and the interior height as 1800. On the left wall, there are two circular openings labeled 'hotwater pipes'. Along the top left wall, several small circles represent 'telecommunication cables'. On the right wall, a vertical stack of circles represents 'electric power cables'. At the bottom right, a single circle represents a 'water pipe'. The label 'L.063\_F1.5' is located at the bottom right of the diagram.
+
+Diagram of an underground collector showing dimensions and internal components.
+
+**Figure I.5 – Underground collector**
+
+In some cities the communication optical fibre cables are installed in subway tunnels. Special brackets are used. Inside the passenger stations, cables are laid under the platform; they are led into the tunnel through vertical well holes. Inside those holes, cables are attached to walls by special metal clamps.
+
+## I.2 Fire safety in manholes, collectors and tunnels
+
+Before undertaking any work in manholes and collectors, a gas analyser is used to check for gas. If gas is detected, electrical fans are used to provide forced ventilation. In the absence of gas, natural ventilation through the open ducts is sufficient.
+
+Special copper-covered tools are provided for operating the manhole cover. In winter, if the cover freezes to the frame of the hatch, hot sand is to be used for opening the manhole cover.
+
+For operating in the manhole, a crew of at least two workers should be used. One worker should always stay outside the manhole.
+
+Lighting in manholes and collectors should be by means of low voltage (12V) systems. Low-voltage or portable batteries may also be used.
+
+It is forbidden to have an open flame in manholes and collectors.
+
+Contact with power cables is strictly forbidden; this includes a ban on putting any tools or materials on these cables.
+
+In tunnels, only special fire-retardant cables should be used. These cables may use PVC, LSOH or other non-inflammable sheaths. In subway tunnels, heat sensor units are installed. Heat sensors and smoke sensors are installed in each station. Fire hydrants and hand-operated carbon dioxide fire extinguishers are also installed in each station.
+
+## Appendix II
+
+## Brazilian experience
+
+## Safety of personnel for installation in infrastructures of power lines distribution
+
+The following points are excerpts from the relevant Brazilian regulations.
+
+- It is recommended not to install telephones cables on the same infrastructure as electric power installations with a voltage higher than 75 kV.
+- It is recommended that telephones networks not be routed in parallel with electric power network lines with a nominal voltage higher than 35 kV.
+- The ground resistance must not exceed 13 Ω.
+- The following distances between networks are recommended:
+
+| Voltage (V) | Minimum distance (m) |
+|-----------------------|----------------------|
+| Up to 600 | 0.60 |
+| from 600 to 15 000 | 1.30 |
+| from 15 000 to 35 000 | 1.80 |
+| from 35 000 to 70 000 | 2.20 |
+
+- Crossings of telephone networks and electrical power networks of up to 70 kV must observe a $90^{\circ}\pm 15^{\circ}$ angle.
+- Crossings of telephone networks and electrical power networks with voltage between 35 kV and 70 kV should have the messenger grounded on both sides of the power line, with a maximum ground resistance of 30 Ω.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/L/T-REC-L.69-200706-I_PDF-E/raw.md b/marked/L/T-REC-L.69-200706-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..9df89d270068adbf6fe7ad1ceee5742039672dd5
--- /dev/null
+++ b/marked/L/T-REC-L.69-200706-I_PDF-E/raw.md
@@ -0,0 +1,347 @@
+
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**L.69**
+
+(06/2007)
+
+SERIES L: CONSTRUCTION, INSTALLATION AND
+PROTECTION OF CABLES AND OTHER ELEMENTS OF
+OUTSIDE PLANT
+
+---
+
+**Personal digital assistant requirements and
+relevant data structure for infrastructure and
+network elements management**
+
+ITU-T Recommendation L.69
+
+
+
+# **ITU-T Recommendation L.69**
+
+# **Personal digital assistant requirements and relevant data structure for infrastructure and network elements management**
+
+## **Summary**
+
+Telecommunication networks require a minimum of planned periodical maintenance to minimize out-of-service risk and to guarantee Service Level Agreement satisfaction. Especially with respect to optical fibre-based infrastructures, with the corresponding huge amount of information transmitted, the issue is even more critical. There could be many network elements that are subject to maintenance, differing in position, dimension, field work and scheduled times for periodic maintenance.
+
+## **Source**
+
+ITU-T Recommendation L.69 was approved on 29 June 2007 by ITU-T Study Group 6 (2005-2008) under the ITU-T Recommendation A.8 procedure.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2007
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | Page |
+|--------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 4 Abbreviations and acronyms ..... | 1 |
+| 5 PDA ..... | 2 |
+| 5.1 Logon..... | 2 |
+| 5.2 Tag reader..... | 2 |
+| 5.3 Positioning system receiver ..... | 2 |
+| 5.4 Network interface ..... | 3 |
+| 5.5 Memory ..... | 3 |
+| 5.6 Software upgrade..... | 4 |
+| 5.7 Power supply ..... | 4 |
+| 5.8 Case ..... | 4 |
+| 6 Data structure..... | 4 |
+| 6.1 Site information ..... | 4 |
+| 6.2 Element characteristics..... | 5 |
+| 6.3 Installation characteristics ..... | 5 |
+| 6.4 Maintenance report..... | 5 |
+| Appendix I – Italian experience regarding RFID tag solution for telephony poles..... | 6 |
+
+
+
+## Personal digital assistant requirements and relevant data structure for infrastructure and network elements management
+
+# 1 Scope
+
+This Recommendation deals with telecommunication networks maintenance support system. In particular, it points out requirements for personal digital assistant (PDA) equipment used in field activities and data structure for information storage. PDA supports operators for paperless data collection and automatic database upgrade.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T L.64] ITU-T Recommendation L.64 (2007), *ID tag requirements for infrastructure and network elements management*.
+
+[IEC 60529] IEC 60529 (2001), *Degrees of protection provided by enclosures (IP code)*.
+
+# 3 Definitions
+
+*None.*
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|-----------------------------------------|
+| GPRS | General Packet Radio Service |
+| GPS | Global Positioning System |
+| GSM | Global System for Mobile communications |
+| ID | IDentification |
+| IP | Ingress Protection |
+| ISM | Industrial, Scientific, Medical |
+| MMC | MultiMedia Card |
+| OSS | Operations Support System |
+| PDA | Personal Digital Assistant |
+| QR | Quick Response |
+| RFID | Radio Frequency Identification |
+
+# **5 Personal Digital Assistant (PDA)**
+
+A PDA is a handheld device used by an operator as support for in-field maintenance activities.
+
+Along with typical equipment available in electronic devices with man-machine interface (e.g., keyboard, display, etc.), it is recommended that PDAs be equipped with a tag reader to read/write tags (RFID, barcode, QR, etc.). It is suggested that PDAs also be equipped with a positioning system receiver to acquire geographical position, and with a network interface to communicate with the OSS.
+
+## **5.1 Logon**
+
+It is recommended that PDAs support logon based on username and password. All the procedures executed on a PDA are then associated with its operator in order to certify in-field activities and to have a person responsible for data structure content.
+
+## **5.2 Tag reader**
+
+A tag reader is used to acquire the unique ID code associated to the tag.
+
+Tag readers should easily read tags according to their position on the network element and to the minimum distance that can be achieved between tag and reader.
+
+When tags are situated close together, the tag reader should be able to read data of multi tags one at a time (anti-collision function).
+
+It is recommended that between reader and tag there be no materials that could negatively affect radio transmission at the frequency used for tag reading.
+
+If the tag cannot be read or it has been removed from the network element, the PDA should support the communication of this problem by the operator to the OSS.
+
+It is recommended that the tag reader be able to read and write to the tag memory, where available and allowed, in the same conditions as described above.
+
+Each time the tag memory writing procedure is executed, it is recommended that this operation be automatically followed by a read operation in order to verify that the data was correctly written into the tag.
+
+It is recommended that PDAs support a diagnostic test procedure to enable the operator to check that the tag reader is functioning properly.
+
+It is recommended that tag readers be based on a standard technology for wireless communication.
+
+## **5.3 Positioning system receiver**
+
+It is not mandatory but it is suggested that PDAs be equipped with a positioning system receiver.
+
+Positioning system receivers are used to acquire geographical coordinates (latitude, longitude, altitude) of network elements in outside plants where such a service is available. It is recommended that this interface be able to determine the geographical coordinates with a precision (spatial resolution) satisfying the application requirements, even in difficult environmental conditions.
+
+When small distances between items in the same site cannot be discriminated by the positioning system, it is suggested to use the same set of geographical coordinates for all these network elements (site coordinates).
+
+In case of indoor applications, it is suggested to determine an outdoor position to be used as geographical coordinates for all the indoor network elements, or to define the entire site as an outside network element with geographical coordinates, where all the network elements are inside.
+
+In case of failure in determining a geographical position, it is recommended that operators be warned so they can decide on how to proceed.
+
+It is recommended that PDAs support a diagnostic test procedure to enable the operator to check that the positioning system receiver is functioning properly.
+
+It is recommended that the positioning system receiver be based on a standard technology for wireless communication.
+
+## **5.4 Network interface**
+
+It is not mandatory but it is suggested that PDAs be equipped with a network interface.
+
+Network interfaces are used to exchange information with the OSS through a telecommunication network. It is recommended that PDAs communicate with the OSS in a client/server architecture where the PDA is the client.
+
+The PDA can be used to send information to the OSS (e.g., to be stored in the database after maintenance activity) and to collect information from the OSS (e.g., to support before maintenance activity). If both downlink and uplink bandwidths are fundamental, it is suggested that the network interface support symmetrical connection.
+
+Since network connectivity requirements can be different, depending on site position and network availability, it is recommended that PDAs support at least the communication interface that guarantees on average the best performances in terms of connection availability and bandwidth.
+
+Connection availability and bandwidth define the delay between in-field maintenance activity and central database update.
+
+PDAs can support multiple network interfaces to offer best solution according to site characteristic.
+
+In case of communication failure, it is recommended that operators be immediately warned, so that they can decide on how to proceed.
+
+It is recommended that PDAs support a diagnostic test procedure to enable the operator to check that the network interface is functioning properly.
+
+It is recommended that network interfaces be based on a standard technology to communicate with the OSS.
+
+## **5.5 Memory**
+
+It is recommended that PDAs be equipped with a rewritable non-volatile memory. Memory is used to store both the data that must be transferred to the OSS (upload) and the data that can be received from the OSS (download).
+
+Memory should be able to store enough information so PDAs can work continuously from two consecutive download or upload procedures, according to scheduled in-field activities.
+
+It is recommended that memory be able to store both the current running software and new software version in order to support secure software upgrades.
+
+Before memory is completely full, it is recommended that operators be warned, so that they can decide on how to proceed. This may avoid information loss due to inability to save the data into the PDA.
+
+Uploaded data can be deleted only when the OSS has confirmed that information has been received and stored in central database.
+
+Memory can be embedded, detachable, or be a combination of both.
+
+## **5.6 Software upgrade**
+
+Software upgrade on PDAs is necessary to guarantee an acceptable performance (e.g., bug fix and stability). It is suggested to use the supported network interface(s), where available, or a detachable memory device to download new software versions. It is recommended that the integrity of new software be checked before making the change definitive in the PDA, in particular if lossy links (e.g., a radio connection) is used to transfer the new software. It is recommended that downgrading software on PDA be blocked, or that the operator be warned.
+
+In case of tag equipped with a non-volatile memory that has been previously written, it is recommended that new software version can still read and write tag memory.
+
+In case of data structure extension, it is recommended that the new software version be able to manage previous data structures.
+
+## **5.7 Power supply**
+
+PDAs support several electrical interfaces, and total power consumption depends on how much time these devices are switched on and remain active. It is recommended that power supplies be able to support PDAs working for all activities for at least one whole day.
+
+It is recommended that PDAs support a function that enables the operator to monitor the battery residual charge.
+
+Before the PDA's battery is completely exhausted, it is recommended that operators be warned, so that they can decide on how to proceed and thereby avoid information loss.
+
+In heavy power-consuming conditions, it is suggested to have an alternative power supply solution (e.g., a spare battery pack or car charger).
+
+Fast rechargeable battery packs with no memory effect are preferred to other types of batteries.
+
+## **5.8 Case**
+
+It is recommended that PDA cases guarantee normal functioning during in-field activities in typical outside plants environmental conditions. The PDA case should have a degree of protection at least equal to IP54 [IEC 60529].
+
+# **6 Data structure**
+
+A data structure is the set of information relevant for each network element. Typical data structures are divided into the following parts: site, native characteristics, installation characteristics, and maintenance report. Each part consists of data with specific meaning and use.
+
+Values in data structure are entered in a PDA for the first time by its operator during the census phase. Census is the system start-up process where network elements are registered in the OSS database. Part of these values could be already written in the tag if the tag has an embedded non-volatile memory and has been supplied together with the network element.
+
+Part of the data structure content for a network element changes every time maintenance activity takes place. Consequently, the central database content is also upgraded.
+
+## **6.1 Site information**
+
+Site information of network elements defines their position in terms of location (e.g., geographical coordinates and addresses) and in terms of network hierarchal status (e.g., a site belonging to a certain network area).
+
+It is recommended to enter, record and store site information in order to have a clear frame of the entire network hierarchy. Such information facilitates finding network elements on maps and in databases and can be used in the future to reach the site and then the network element.
+
+## **6.2 Element characteristics**
+
+Element characteristics are typical of network elements as produced by the manufacturer (e.g., model, serial number, etc.). If the network element is supplied with a tag that embeds non-volatile memory, such information might already be stored in the tag.
+
+It is recommended to enter, record and store network elements native information in order to make available in a database all data that can be mandatory or useful for future maintenance activities (such as substitution or repair).
+
+## **6.3 Installation characteristics**
+
+Installation characteristics of network elements are defined when the installation takes place and takes into consideration external conditions (e.g., ground typology, such as where a telephonic pole is installed).
+
+It is recommended to enter, record and store installation information of network elements in order to make available in a database all data that can be mandatory or useful for future maintenance activities (such as substitution or repair).
+
+## **6.4 Maintenance report**
+
+The maintenance report is the set of information that describes the in-field maintenance executed, tests performed and their results.
+
+It is recommended to enter, record and store maintenance report information in order to make available in a database all data that can be mandatory or useful for typical procedures in OSS (e.g., monitoring and analysis).
+
+It is recommended to record and store information about the operator responsible for maintenance, and the times of the executed activities.
+
+# Appendix I
+
+## Italian experience regarding RFID tag solution for telephony poles
+
+(This appendix does not form an integral part of this Recommendation)
+
+In Italy, RFID technology for maintenance support has been tested on poles used in the wireline access network throughout all the country, where the wooden poles represent the near totality of the poles used in this kind of network.
+
+The first step was to trace the in-field maintenance actions and to collect more information on these items, in order to better understand the causes of poles turnover. On the one side, better knowledge of the pole network meant avoiding random and massive monitoring actions, better spare parts management and network planning. On the other side, information maintenance can be certified because the tag is on the pole and stores information about the latest actions (date, operator code, etc.).
+
+Typical periodical maintenance requires checking all poles inside a network area. More than 40'000 poles have been checked in several networks areas spread across Italy.
+
+PDAs used for this application (see Figure I.1) are equipped with a GPS receiver, a GPRS/GSM modem, a RFID tag reader and support an MMC memory card.
+
+The RFID tag reader is compliant with ISO 14443 (proximity standard) and operates in the ISM band of 13.56 MHz. It is used to read and write ISO 14443 RFID tags fixed on poles.
+
+The GPS receiver is a 12-channel receiver used to acquire geographical coordinates.
+
+A GPRS/GSM modem is used to communicate with OSS.
+
+The MMC memory card is a detachable support used to store data and software.
+
+The data structure used for this application is shown in Table I.1
+
+
+
+A yellow handheld PDA device with a screen and a keypad. The screen displays 'TAG GPS POLE IDENTIFIER', 'GPS 12 CHANNEL SATELLITE RECEIVER', and 'GPRS DUAL BAND INTERNAL MODEM'. The keypad has buttons labeled F1, F2, F3, F4, and a numeric keypad with additional function icons.
+
+Figure I.1 – PDA
+
+**Table I.1 – Data structure for telephony poles**
+
+| | |
+|------------------------------|------------------------------|
+| Site information | Geographical coordinates |
+| | Network area |
+| Element characteristics | Production year |
+| | Material |
+| | Length |
+| | Capacity |
+| Installation characteristics | Type |
+| | Area |
+| | Ground |
+| | Presence of hanging strand |
+| | Presence of any box |
+| | Presence of grounding system |
+| Maintenance report | State of conservation |
+| | Result |
+| | Maintenance actions |
+| | Date |
+| | Operator |
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bda9682c9b2f8d42f44355c82079fb6946ee9faa
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:686bd85f54b134e72cc4f598ef0d2c6d6375597842029157a08d5999a24a53a0
+size 38786
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/2ba086df3506f81bae3a9b53725dcfea_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/2ba086df3506f81bae3a9b53725dcfea_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..aa8aa2089905df4a71e46d737c39546416536843
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/2ba086df3506f81bae3a9b53725dcfea_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fc3b6c6f6a40cc8a042159a3b112c36f005e0a0650f5e01ba438b9b3cb4f6169
+size 22790
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ac1c2b5a8dbc4d75a7afccf1674f229f08ebbf6a
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:238a452928b8b6e846b60c0f1f9871d0f1d445b151b19b68b454c7098f6b5aeb
+size 24267
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/a8e5c2ac336eb43cda4e333ea9c73237_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/a8e5c2ac336eb43cda4e333ea9c73237_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ac1572979c1fe717f4951756003552da8283284f
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/a8e5c2ac336eb43cda4e333ea9c73237_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f023e52b091bd238d776cd4a9591be9b12bd3971d5652ec8659fb9b9e5ac108d
+size 43959
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9041341b59e34e593c27981bdf689e763e911cfb
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/d26959f4514c26ca19c3d6f00da85956_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1002149a395bcc0a6de0c5fb6dd4a083c09987e9cc945eac860711b79a1d108f
+size 38010
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7879b89a3eaaee35e80b830f4aa28fd7cdd65312
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7ab9abd6c999d5e986c3d67ee9efeff8a0a0d86610f2abc9ef592e495d229454
+size 52267
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2d6d228ffd00cdd81d728d9880274076cd529ab7
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c1588e01d6843bb25510b2c7abcba655500c3c2ca39c726d79c1d2642d9952dd
+size 25776
diff --git a/marked/Y/T-REC-F.747.7-201410-I_PDF-E/raw.md b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..179ee3332817d2b2d03d18a0f91eab71b4663882
--- /dev/null
+++ b/marked/Y/T-REC-F.747.7-201410-I_PDF-E/raw.md
@@ -0,0 +1,502 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## F.747.7
+
+(10/2014)
+
+SERIES F: NON-TELEPHONE TELECOMMUNICATION
+SERVICES
+
+Audiovisual services
+
+# --- **Requirements for network-based location information conversion for location-based applications and services**
+
+Recommendation ITU-T F.747.7
+
+## ITU-T F-SERIES RECOMMENDATIONS **NON-TELEPHONE TELECOMMUNICATION SERVICES**
+
+| | |
+|-----------------------------------------------------------------|--------------------|
+| TELEGRAPH SERVICE | |
+| Operating methods for the international public telegram service | F.1–F.19 |
+| The gentex network | F.20–F.29 |
+| Message switching | F.30–F.39 |
+| The international telemesssage service | F.40–F.58 |
+| The international telex service | F.59–F.89 |
+| Statistics and publications on international telegraph services | F.90–F.99 |
+| Scheduled and leased communication services | F.100–F.104 |
+| Phototelegraph service | F.105–F.109 |
+| MOBILE SERVICE | |
+| Mobile services and multideestination satellite services | F.110–F.159 |
+| TELEMATIC SERVICES | |
+| Public facsimile service | F.160–F.199 |
+| Teletex service | F.200–F.299 |
+| Videotex service | F.300–F.349 |
+| General provisions for telematic services | F.350–F.399 |
+| MESSAGE HANDLING SERVICES | F.400–F.499 |
+| DIRECTORY SERVICES | F.500–F.549 |
+| DOCUMENT COMMUNICATION | |
+| Document communication | F.550–F.579 |
+| Programming communication interfaces | F.580–F.599 |
+| DATA TRANSMISSION SERVICES | F.600–F.699 |
+| AUDIOVISUAL SERVICES | F.700–F.799 |
+| ISDN SERVICES | F.800–F.849 |
+| UNIVERSAL PERSONAL TELECOMMUNICATION | F.850–F.899 |
+| HUMAN FACTORS | F.900–F.999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T F.747.7
+
+# Requirements for network-based location information conversion for location-based applications and services
+
+## Summary
+
+Recommendation ITU-T F.747.7 defines the scenarios and the functional requirements for network-based location information conversion (NBLIC) for different applications and services. The NBLIC system provides the translation capability through specific algorithms, which can present location information in different formats to fit in various scenarios. The system also provides diverse functions and capabilities, such as interoperability, security, and privacy protection to the retrieved location data and to the converted information.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T F.747.7 | 2014-10-14 | 16 | 11.1002/1000/12227 |
+
+## Keywords
+
+Location-based services, location information conversion.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|----------------------------------------------------------------------|-------------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation ..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 NBLIC scenarios for location-based applications and services ..... | 3 |
+| 6.1 Centralized location information conversion model ..... | 3 |
+| 6.2 Decentralized location information conversion model..... | 4 |
+| 6.3 Hybrid location information conversion model ..... | 5 |
+| 7 Requirements for the NBLIC services framework ..... | 6 |
+| 7.1 High-level requirements ..... | 6 |
+| 7.2 System requirements ..... | 7 |
+| Appendix I – NBLIC use cases ..... | 8 |
+| I.1 Translation scenarios and procedures..... | 8 |
+| Bibliography..... | 12 |
+
+# **Introduction**
+
+Location-based services (LBS) are widely used. However, the different uses addressed by different applications require dissimilar types of positioning results, and in addition, the various positioning systems provide location information in varied formats. For example, an automobile navigation application in a shopping mall car park usually requires the location information in the format of longitude and latitude, while the indoor positioning system of the mall's parking lot offers the result in Cartesian coordinates. To reduce the number of positioning systems and make full use of the functionality of positioning systems, it is required to remove incompatibilities between the original positioning results and the appropriate results fitting the needs of an application.
+
+A network-based location information conversion (NBLIC) system can be employed to help applications understand the location information written in different formats and coordinates. The location conversion system works either locally or globally, depending on the system structure. It provides translation functions to applications, and translates the positioning results from the original format to the required one. For example, it could translate the Cartesian coordinate positioning result (offered by the parking lot positioning system) into longitude and latitude according to the application's requirement.
+
+Recommendation ITU-T F.747.7 identifies the scenarios and requirements for NBLIC system for location-based applications and services.
+
+###### Recommendation ITU-T F.747.7
+
+# Requirements for network-based location information conversion for location-based applications and services
+
+# 1 Scope
+
+Location-based services (LBS) are utilized to bring considerable convenience to our daily life. However, due to the dissimilar purposes of LBS applications, the required formats of the location information are often different. The network-based location information conversion (NBLIC) systems are employed, serving as an effective middle-ware to help location information to be accessed and understood by multiple applications and services. This Recommendation describes some typical scenarios and specifies the functional requirements according to these scenarios.
+
+The scope of this Recommendation includes:
+
+- the definition of NBLIC;
+- the specific scenarios of NBLIC;
+- the functional requirements for NBLIC.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T F.747.5] Recommendation ITU-T F.747.5 (2014), *Requirements and functional architecture of an automatic location identification system for ubiquitous sensor network applications and services*.
+- [ITU-T Y.2221] Recommendation ITU-T Y.2221 (2010), *Requirements for support of ubiquitous sensor network (USN) applications and services in the NGN environment*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 automatic location identification (ALI) system** [ITU-T F.747.5]: ALI system is a set of interacting or interdependent components forming an integrated whole or a set of elements to offer the ALI service.
+
+**3.1.2 sensor** [ITU-T Y.2221]: Electronic device that senses a physical condition or chemical compound and delivers an electronic signal proportional to the observed characteristic.
+
+**3.1.3 sensor network** [ITU-T Y.2221]: A network comprised of inter-connected sensor nodes exchanging sensed data by wired or wireless communication.
+
+**3.1.4 ubiquitous sensor network** [ITU-T Y.2221]: A conceptual network built over existing physical networks which makes use of sensed data and provides knowledge services to anyone, anywhere and at any time, and where the information is generated by using context awareness.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 network-based location information conversion (NBLIC) agent:** A local server of the NBLIC system that acts on behalf of the central server to provide NBLIC services to a subscriber in the situation when the NBLIC system is deployed in a decentralized mode, or in a hybrid mode.
+
+**3.2.2 network-based location information conversion (NBLIC) client:** A terminal device or application consuming NBLIC services.
+
+**3.2.3 network-based location information conversion (NBLIC) service:** A location associated service that provides the best accessible conversions of the positioning results upon request, and the formats of the converted results are in accordance with the requirements for the location-based applications and services.
+
+**3.2.4 network-based location information conversion (NBLIC) subscriber:** A user authorized to use the NBLIC service.
+
+**3.2.5 network-based location information conversion (NBLIC) system:** A set of interacting or interdependent components forming an integrated whole or a set of elements to offer the NBLIC services, which contains one or more databases consisting of a collection of the location information and the associated conversion parameters.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|----------|---------------------------------------------------------|
+| ALI | Automatic Location Identification |
+| CDMA | Code Division Multiple Access |
+| GPS | Global Positioning System |
+| GSM | Global System for Mobile communications |
+| HRPD | High-Rate Packet Data |
+| IoT | Internet of Things |
+| LBS | Location-Based Services |
+| LTE | Long Term Evolution |
+| NBLIC | Network-Based Location Information Conversion |
+| NFC | Near-Field Communication |
+| QoS | Quality of Service |
+| QR | Quick Response |
+| SMS | Short Message Service |
+| TD-SCDMA | Time Division-Synchronous Code Division Multiple Access |
+| USN | Ubiquitous Sensor Network |
+| UWB | Ultra-Wide Band |
+| WCDMA | Wideband Code Division Multiple Access |
+
+| | |
+|-------|-------------------------------------------------|
+| WiMAX | Worldwide interoperability for Microwave Access |
+| WLAN | Wireless Local Area Network |
+
+# 5 Conventions
+
+In this Recommendation, the following conventions apply.
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement need not be present to claim conformance.
+
+The keywords "can optionally" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# 6 NBLIC scenarios for location-based applications and services
+
+The network-based location information conversion (NBLIC) service is defined to translate a positioning result into a desired format. The NBLIC service could be:
+
+- part of a positioning system, such as the coordinate conversion function of automatic location identification (ALI) systems (defined in [ITU-T F.747.5]) for Internet of things (IoT) applications;
+- integrated in entities within distributed positioning systems; or
+- a stand-alone service.
+
+As a result, there are different levels of the deployment of NBLIC functionalities. The following clauses describe the scenarios that are based on the different deployments of the NBLIC functionalities.
+
+## 6.1 Centralized location information conversion model
+
+This scenario is illustrated in Figure 1 and it describes the situation where the NBLIC service is deployed in a centralized server of the stand-alone service, or in a centralized positioning system as its function entities.
+
+
+
+```
+
+graph BT
+ Subscriber[Subscriber] <--> Network((Network))
+ Network <--> NBLIC_server[NBLIC server]
+ style NBLIC_server fill:none,stroke:none
+ subgraph ServerBox [ ]
+ direction TB
+ Cylinders[(Three yellow cylinders)]
+ NBLIC_server
+ end
+
+```
+
+F.747.7(14)\_F01
+
+Diagram of the centralized location information conversion model. It shows a Subscriber at the bottom, connected to a Network cloud in the middle, which is connected to an NBLIC server at the top. The NBLIC server is represented by a rectangle containing three yellow cylinders and the text 'NBLIC server'. Arrows indicate bidirectional communication between the Subscriber and the Network, and between the Network and the NBLIC server.
+
+**Figure 1 – Scenario for location translation conversion using NBLIC services via centralized model**
+
+**Description:** This is the scenario where all the location conversion information is stored in a single centralized server or a handful of centralized servers.
+
+**Pre-conditions:** In the centralized model, all the conversion information is held in the centralized server. The centralized server authorizes the subscribers to use all the information stored in the NBLIC system.
+
+In this scenario:
+
+1. The subscriber's client sends the request to the centralized server of the NBLIC system.
+2. Upon receiving the request, the centralized server looks up the subscriber from the authorization entity, and then authorizes the subscriber if it is a NBLIC subscriber.
+3. After the authorization, the NBLIC system replies to the subscriber with a "successful authorization" message.
+4. The subscriber's client sends a conversion request, which also includes the original location information, to the centralized server.
+5. The NBLIC system translates the location information to the required format, and returns the result to the subscriber.
+
+## 6.2 Decentralized location information conversion model
+
+This scenario is illustrated in Figure 2 and it describes the situation where the NBLIC service is deployed in the distributed servers, or in a distributed positioning system as its function entities.
+
+
+
+The diagram illustrates a decentralized NBLIC model. At the top, three NBLIC servers (A, B, and C) are shown, each represented by a box containing three yellow cylinders. These servers are interconnected by bidirectional arrows, indicating a distributed system. Below the servers is a cloud labeled 'Network'. A double-headed arrow connects the network to the servers. At the bottom, a 'Subscriber' is depicted as a person sitting at a desk with a computer. An arrow points from the subscriber to the network cloud. The identifier 'F.747.7(14)\_F02' is located at the bottom right of the diagram.
+
+Diagram of a decentralized NBLIC model showing three servers (A, B, C) connected to a central network, which is accessed by a subscriber.
+
+**Figure 2 – Scenario for location translation conversion using NBLIC services via a decentralized model**
+
+**Description:** This is the scenario where all location information conversion is fully decentralized across distributed positioning systems. Distributed search algorithms often use the flooding query method to look for the appropriate NBLIC server.
+
+**Pre-conditions:** In the decentralized model, NBLIC servers A to C each store a part of the conversion information and acts as an agent for the NBLIC system. Each server contains the full conversion information for a particular geographic area, i.e., NBLIC-A for area A, and NBLIC-B for area B. The subscriber, who moves from area B to area A, wants to translate the location information. All or some of the subscribers are authorized to use the NBLIC services.
+
+In this scenario:
+
+1. The subscriber in area B moves to area A. It sends the request to server A asking for NBLIC services.
+2. Upon receiving the request, NBLIC server A sends the request to NBLIC server B in order to authorize the request.
+3. After the authorization, NBLIC server A replies to the subscriber with a "successful authorization" message.
+4. The subscriber's client sends a conversion request to NBLIC server A, which includes the original location information.
+5. NBLIC server A translates the requested location to the required format, and returns it to the subscriber.
+
+## 6.3 Hybrid location information conversion model
+
+This scenario is illustrated in Figure 3 and it describes the situation where the NBLIC service is deployed in several servers, or in a distributed positioning system, as functional entities. Compared with the scenario described in clause 6.2, in this scenario, a central server is introduced to cooperate with the distributed servers (agents) to provide the NBLIC services.
+
+
+
+The diagram illustrates a hybrid NBLIC model. At the top, a large rectangular box contains three main components: 'NBLIC server B' on the left, 'NBLIC central system' in the center, and 'NBLIC server A' on the right. Each server is represented by a rectangle with three yellow cylinders above it. Bidirectional arrows connect 'NBLIC server B' and 'NBLIC server A' to the 'NBLIC central system'. Below this box is a cloud labeled 'Network'. A double-headed vertical arrow connects the 'NBLIC central system' box to the 'Network' cloud. At the bottom, a 'Subscriber' is shown as a person sitting at a desk with a computer. A double-headed vertical arrow connects the 'Subscriber' to the 'Network' cloud. The identifier 'F.747.7(14)\_F03' is located at the bottom right of the diagram.
+
+Diagram of the hybrid NBLIC model showing a central system and two decentralized servers connected to a network and a subscriber.
+
+**Figure 3 – Scenario for location translation conversion using NBLIC services via a hybrid model**
+
+**Description:** This scenario is where both a central NBLIC server and decentralized servers exist in the system. All location information conversion is stored in the central NBLIC server, while each decentralized system stores a part of the information related to its geographic area.
+
+**Pre-conditions:** In the hybrid model, the NBLIC functions are distributed amongst the decentralized positioning systems and a central server. Each NBLIC distributed server (agent) has a part of the conversion information related to its geographic area. NBLIC-A has the whole NBLIC information for area A and NBLIC-B for area B, etc. The central NBLIC has all the NBLIC information. Subscriber A wants to translate some location information. All or some of the users are authorized to use NBLIC services.
+
+In this scenario:
+
+1. A subscriber in area A moves to area B. A request is sent to server B of the NBLIC system.
+2. Upon receiving the request, server B sends the request to the centralized NBLIC server in order to authenticate and authorize the request.
+3. After authorization, server B replies to the subscriber with a "successful authorization" message.
+4. The subscriber's client sends a conversion request to server B, which includes the original location information.
+5. Server B sends the request to the centralized NBLIC server.
+6. The central NBLIC server translates the request location into the required format, and returns it to server B.
+7. Server B returns the translated location information to the subscriber's client.
+
+# **7 Requirements for the NBLIC services framework**
+
+## **7.1 High-level requirements**
+
+### **7.1.1 Interoperability**
+
+**INT-01:** The NBLIC architecture is required to allow co-existence with existing location information translation standards, such as geocoding standards and other related standards specified by other standards development organizations (SDOs) such as open geospatial consortium (OGC) [b-OGC 08-062r7], 3rd generation partnership project 2 (3GPP2) [b-3GPP2 IP-BLS], [b-3GPP2 MAP-LS], 3GPP [b-3GPP LCS]. The introduction of a NBLIC system is required not to have any negative impact on the operation and performance of existing standards.
+
+**INT-02:** The NBLIC architecture is recommended to support seamless location information translation requests from moving subscribers. For example, if a subscriber's client contacts a server of the NBLIC system and then moves, the subscriber will receive the same format from multiple servers.
+
+**INT-03:** The NBLIC architecture is recommended to support the ability for the different scenarios (the centralized, decentralized and hybrid scenarios) to provide the NBLIC capabilities to the network.
+
+**INT-04:** The NBLIC is recommended to provide the capability to negotiate features between NBLIC elements. An example would be to revert to an earlier version of the system, if reversion is allowed by the NBLIC provider and the requested service is available in the earlier version.
+
+### **7.1.2 Translation determination**
+
+**TRA-01:** The NBLIC architecture is required to support location translation procedures, which it performs in collaboration with the target NBLIC clients and the NBLIC functional entities resident within the possible positioning systems.
+
+**TRA-02:** All translated data from the NBLIC system is recommended to be time-stamped.
+
+**TRA-03:** The NBLIC system can optionally support the specification of the desired quality of service (QoS) in a NBLIC client location request, including, but not limited to, accuracy and response time.
+
+**TRA-04:** The NBLIC architecture can optionally support triggered NBLIC requests, such as event-based NBLIC requests, or the requests triggered by some other conditions.
+
+### 7.1.3 Security
+
+**SEC-01:** The NBLIC architecture is required to ensure that any location information that is exchanged is secure, and thus is not accessible to unauthorized access, i.e., unauthorized disclosure or usage. Loss or corruption of location data is to be prevented.
+
+**SEC-02:** If the NBLIC system provides the ability for the client or the agent to store the conversion information, the data is required to be stored in a secure manner, and is recommended to be available for retrieval by authorized applications.
+
+**SEC-03:** The NBLIC system is required to deliver its content in a trustworthy and reliable manner, e.g., location information is required to be protected against eavesdropping or modification of the data traffic.
+
+**SEC-04:** It is recommended to be possible to authenticate the NBLIC agent, the NBLIC network and the subscriber's client.
+
+**SEC-05:** The NBLIC architecture is recommended to provide mechanisms to prevent denial of service attacks.
+
+### 7.1.4 Privacy
+
+**PRI-01:** The NBLIC system is required to ensure that data is protected in all transactions, consistent with the user's privacy preferences, except for emergency or lawful purposes depending on local/regional regulations.
+
+**PRI-02:** NBLIC applications, agents, networks and clients can be a part of several domains. If the NBLIC services are available in several domains, the NBLIC architecture is recommended to support synchronization using secure mechanisms (e.g., encryption).
+
+**PRI-03:** If the policy owner has defined different privacy settings for different data, the NBLIC architecture can optionally support a privacy check after each translation, to make sure the data is satisfying the different settings.
+
+### 7.1.5 Implementation
+
+**IMP-01:** The NBLIC architecture is recommended to support value-added commercial applications within its technical limitations.
+
+## 7.2 System requirements
+
+**SYS-01:** The NBLIC architecture is required not to impose any requirements on the underlying network service. It is required that NBLIC does not modify the reference architecture or functionality of the underlying network technology.
+
+**SYS-02:** The NBLIC architecture is recommended to be compatible with all underlying network technologies. For example, air interface standards (such as global system for mobile communications (GSM), code division multiple access (CDMA), wideband CDMA (WCDMA)/time division-synchronous CDMA (TD-SCDMA), long term evolution (LTE), high rate packet data (HRPD), ultra-wide band (UWB), wireless local area network (WLAN), worldwide interoperability for microwave access (WiMAX), USN) and related transport media (packet data services, short message services (SMS), etc.) are recommended be supported.
+
+**SYS-03:** The functions introduced by the NBLIC system are recommended to be either hosted in existing function elements of location-based service systems, or in completely new physical entities. The NBLIC system is recommended not to impose any modifications on the reference architecture or functionality of existing positioning technologies.
+
+**SYS-04:** The NBLIC architecture and specifications are recommended not to prevent the client from choosing different NBLIC service providers.
+
+# Appendix I
+
+## NBLIC use cases
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The following content describes the possible use cases in the NBLIC system:
+
+### I.1 Translation scenarios and procedures
+
+Geographic representation is the demonstration of position, which includes common geographic coordinates of longitude, latitude and elevation, Cartesian coordinates, streets addresses, shop names, postal codes, country codes, Maidenhead locator systems and area codes, etc. The following use cases describe circumstances during which NBLIC services could be employed.
+
+#### I.1.1 Translation from vague geographic representations to precise ones
+
+In this use case, the subscriber requires location in a more accurate format than what had been previously provided, which means the previous location result does not meet this requirement. As a result, the subscriber's client has to repeat the positioning process and send the new location information to the NBLIC system to ensure everything works smoothly. In other words, the NBLIC works with different positioning systems to provide the best available location information. The following use case describes this circumstance.
+
+
+
+The diagram illustrates the translation process from vague to precise geographic representations. It consists of three stages connected by arrows:
+
+- Stage 1 (Vague):** A speech bubble labeled "GPS" contains the coordinates "39.101982, 116.12345". Below it is an illustration of the Eiffel Tower. An orange callout bubble below the tower contains the coordinates "39.101982, 116.12345, 0.".
+- Stage 2 (Intermediate):** An arrow points to a speech bubble labeled "Cartesian" containing "10.1234, 20.1341, 1". Below it is an illustration of a building. An orange callout bubble below the building contains the coordinates "39.101900234, 116.12345231, 1".
+- Stage 3 (Precise):** An arrow points to a speech bubble labeled "Shop XXXX, Area XXXX". Below it is an illustration of a football. An orange callout bubble below the football contains the coordinates "39.101900234, 116.12345231, 1".
+
+F.747.7(14)\_F1.1
+
+Diagram illustrating the translation of vague geographic representations to precise ones. It shows a flow from a GPS location (Eiffel Tower) to Cartesian coordinates (building) to a specific shop location (football).
+
+**Figure I.1 – Use case for translation from vague geographic representations to precise ones**
+
+Figure I.1 illustrates the case that the application requires translation of a vague positioning result to a precise one. A shopping mall application helps customers find the desired goods, and requests the positioning result in the form of longitude, latitude and floor number.
+
+The customer looks for a football in shop A. Before she enters the shopping mall, she drives on the road, and receives longitude 39.101982, latitude 116.123456 from a global positioning system (GPS) device. The NBLIC system translates the location information to 39.101982, 116.12345,0 ("0" here means outdoor), and returns it to the application to help with route-planning. When she enters the shopping mall, the indoor location system provides the location information in Cartesian coordinates, which is 10.1234, 20.1341, 1 (here "1" means indoor, 1st floor). Upon receiving the conversion request, the NBLIC system then translates the positioning result from Cartesian coordinates to the required form of 39.101900234, 116.12345231, 1 (by offsetting from the reference point), to help the application find the customer's position. After entering the shop, it also provides information on the location of the desired goods, and helps the customer find them quickly. The position information of
+
+the goods is usually defined in the terms of "shop A, area AA" by the sensor positioning system in the shop. As a result, the NBLIC system translates this to 39.101900234, 116.12345231, and 1 (according to the index of the shop area location database).
+
+In this use case, the application requires the same format from the different positioning systems. Due to the different accuracy requirements, the NBLIC system is recommended to work together with the applications and the available positioning systems, to obtain a more accurate positioning result, and to provide the most suitable result.
+
+#### **I.1.2 Translation from precise geographic representations to vague ones**
+
+In this case, the application requires a rough location representation, which means the previous location result meets the requirement. Consequently, the application does not have to redo the positioning process, and could use the existing results to do the translation and to reply to the application.
+
+
+
+The diagram shows a person in a white shirt and tie pointing at a black screen. A blue callout bubble from the screen contains the text: "Cartesian 10.1234, 20.1341, 1". A blue arrow points from the person to a cityscape illustration. An orange callout bubble from the cityscape contains the text: "39.101982, 116.12345, 0." Below the cityscape, the text "F.747.7(14)\_Fl.2" is visible.
+
+Diagram illustrating the translation from precise geographic representations to vague ones. A person is shown pointing at a screen displaying Cartesian coordinates (10.1234, 20.1341, 1). An arrow points to a cityscape where a location is marked with a callout showing the translated coordinates (39.101982, 116.12345, 0).
+
+**Figure I.2 – Use case of the translation from precise geographic representations to vague ones**
+
+Figure I.2 illustrates the use case. A school application is created to help students to find their classroom in the school building, and the other application is to help them to find the suitable cafeteria in the same area. The find-classroom application requires the location information in the form of Cartesian coordinate, while the other application asks for the position result in the form of latitude and longitude.
+
+The school application already receives the positioning result from the school indoor location system in the form of 10.1234 and 20.1341 and floor 1. When receiving the translation request from the second location, the NBLIC system finds the previous positioning result meets the accuracy requirement. It then translates the location information into the requested format of longitude 39.101982, latitude 116.123456 (offset from the reference point), and returns it to the application.
+
+In this case, the different applications require different formats. Since the accuracy of the obtained location information meets the requirement, the NBLIC system simply does the translation, and returns the location information in the required format to the application.
+
+#### **I.1.3 Translation from address representations to geographic representations or vice versa**
+
+In this case, the application is required to find the geographic information from the associated address representation, such as a street address. The NBLIC system checks the conversion parameters in the database and does the translation.
+
+The reverse process is to find an associated address representation from the geographic coordinate.
+
+
+
+Diagram illustrating the translation of an address to geographic coordinates. On the left, a man in a white shirt and tie points at a black tablet. A blue speech bubble above him contains the text: 'Hotel Calou, 4, rue Pradier, 1200 Geneva, Switzerland'. A large blue arrow points from the man to a stylized city skyline on the right. An orange speech bubble below the skyline contains the coordinates: '39.101982, 116.12345, 0.' Below the skyline, the text 'F.747.7(14)\_Fl.3' is visible.
+
+**Figure I.3 – Use case of translation from address representations to geographic representations**
+
+Figure I.3 illustrates this use case. A navigation application is required to obtain the geographic coordinates of the destination address.
+
+The application sends an address, which is "Hotel Calou, 12 Geneva Switzerland", to the NBLIC system. The NBLIC system checks the database and realizes that the Hotel Calou, is situated on "4, rue Pradier". The length of rue Pradier is 110 m, and it is numbered from 1 to 50. The even-numbered addresses fall on the east side of the road, while the odd-numbered addresses fall on the west side. By checking the database, the NBLIC system realizes that "4, rue Pradier" would be located at the start, on the east side of the street. Therefore, a point would be mapped at that location along the street, perhaps offset a distance to the start of the street, approximate 39.101982, 116.12345 in terms of longitude and latitude.
+
+#### **I.1.4 Translation from digital string representations to geographic representations**
+
+In this case, the application needs to find the associated geographic information from digital strings, such as quick response (QR) codes (or near-field communication (NFC) codes). QR codes appearing in magazines or on signs (or NFC tags installed at shops or buildings) may store addresses. A camera phone equipped with a specific application can scan the image of the QR code (or with the help of the NFC reader obtain the information from tags). The code could be linked to a specific location. The application scanning the QR code retrieves the geographic information from the NBLIC system encoded in the QR code, or NFC tag.
+
+
+
+A map of Geneva, Switzerland, showing the city and surrounding areas. A QR code is overlaid on the map, with a line pointing to a specific location in the city center. The text 'F.747.7(14)\_Fl.4' is visible at the bottom right of the map.
+
+**Figure I.4 – Use case on digital string representations to geographic representations**
+
+Figure I.4 illustrates this use case. The terminal device is equipped with a camera and scans the QR code image. The digital string encoded in the specific QR code is decoded by the application (client) in the terminal device. The application sends the digital string to NBLIC system, then the system checks the database and translates the digital string to geographic information.
+
+# Bibliography
+
+- [b-3GPP LCS] 3GPP TS 23.271, *Functional stage 2 description of Location Services (LCS)*.
+<> (accessed 2014-01-20)
+- [b-3GPP2 IP-BLS] 3GPP2 X.S0024-0 (2005), *IP-Based Location Services Revision: 0*.
+<[www.3gpp2.org/public\\_html/specs/X.S0024-0\\_v1.0\\_051102.pdf](http://www.3gpp2.org/public_html/specs/X.S0024-0_v1.0_051102.pdf)> (accessed 2014-01-20)
+- [b-3GPP2 MAP-LS] 3GPP2 X.S0002-0 (2006), *MAP Location Services Enhancements (Version 2.0)*.
+<[www.3gpp2.org/public\\_html/specs/X.S0002-0\\_v2.0\\_060531.pdf](http://www.3gpp2.org/public_html/specs/X.S0002-0_v2.0_060531.pdf)> (accessed 2014-01-20)
+- [b-OGC 08-062r7] Open Geospatial Consortium, *OGC Reference model*,
+<> (accessed 2014-01-20)
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|---------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-F.748.1-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-F.748.1-201410-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ecd250ce2e8f2d5a7b9c46349cd105a64d93fc8a
--- /dev/null
+++ b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:69ea22b6f3525a259d9d67e3e9eaa4af499c6fa1a599d96cd4b882e1c57763e1
+size 87274
diff --git a/marked/Y/T-REC-F.748.1-201410-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dd55ab8d95e00dcc4791c2410a4731076a91b002
--- /dev/null
+++ b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1f8724bc856ad6d00d3bf1dcb161afc948df40ffbdfb129cfea9e25c5128db62
+size 98683
diff --git a/marked/Y/T-REC-F.748.1-201410-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..be09d1056338acc3ff6b47622939719fc5725368
--- /dev/null
+++ b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bad28fcab07e2e56e4d7487d4f99a8a42e5e3ba3df478004dda473871c6abb91
+size 103804
diff --git a/marked/Y/T-REC-F.748.1-201410-I_PDF-E/raw.md b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..7ee3dc127cab1c0e8d5a52e53e525714f786cde6
--- /dev/null
+++ b/marked/Y/T-REC-F.748.1-201410-I_PDF-E/raw.md
@@ -0,0 +1,461 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## F.748.1
+
+(10/2014)
+
+SERIES F: NON-TELEPHONE TELECOMMUNICATION
+SERVICES
+
+Audiovisual services
+
+# --- **Requirements and common characteristics of the IoT identifier for the IoT service**
+
+Recommendation ITU-T F.748.1
+
+## ITU-T F-SERIES RECOMMENDATIONS **NON-TELEPHONE TELECOMMUNICATION SERVICES**
+
+| | |
+|-----------------------------------------------------------------|--------------------|
+| TELEGRAPH SERVICE | |
+| Operating methods for the international public telegram service | F.1–F.19 |
+| The gentex network | F.20–F.29 |
+| Message switching | F.30–F.39 |
+| The international telemessage service | F.40–F.58 |
+| The international telex service | F.59–F.89 |
+| Statistics and publications on international telegraph services | F.90–F.99 |
+| Scheduled and leased communication services | F.100–F.104 |
+| Phototelegraph service | F.105–F.109 |
+| MOBILE SERVICE | |
+| Mobile services and multideestination satellite services | F.110–F.159 |
+| TELEMATIC SERVICES | |
+| Public facsimile service | F.160–F.199 |
+| Teletex service | F.200–F.299 |
+| Videotex service | F.300–F.349 |
+| General provisions for telematic services | F.350–F.399 |
+| MESSAGE HANDLING SERVICES | F.400–F.499 |
+| DIRECTORY SERVICES | F.500–F.549 |
+| DOCUMENT COMMUNICATION | |
+| Document communication | F.550–F.579 |
+| Programming communication interfaces | F.580–F.599 |
+| DATA TRANSMISSION SERVICES | F.600–F.699 |
+| AUDIOVISUAL SERVICES | F.700–F.799 |
+| ISDN SERVICES | F.800–F.849 |
+| UNIVERSAL PERSONAL TELECOMMUNICATION | F.850–F.899 |
+| HUMAN FACTORS | F.900–F.999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T F.748.1
+
+# Requirements and common characteristics of the IoT identifier for the IoT service
+
+## Summary
+
+Recommendation ITU-T F.748.1 describes the requirements and common characteristics of the Internet of things (IoT) identifier for the IoT service.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|------------------------------------------------------------------------------|
+| 1.0 | ITU-T F.748.1 | 2014-10-14 | 16 | 11.1002/1000/12229 |
+
+## Keywords
+
+Identifier, IoT.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-------------------------------------------------------------------|-------------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation ..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Introduction of the IoT identifier ..... | 3 |
+| 7 Analysis of identifiers in the existing technologies ..... | 4 |
+| 8 Common characteristics of the IoT identifier ..... | 5 |
+| 9 Requirements of the IoT identifier ..... | 6 |
+| 9.1 Identifying anything ..... | 6 |
+| 9.2 Communication between things ..... | 6 |
+| 9.3 Association between physical objects and virtual objects..... | 6 |
+| 9.4 Networking technology independency ..... | 6 |
+| 9.5 Mapping identifiers to objects ..... | 7 |
+| 9.6 Relation between characteristics and requirements..... | 7 |
+| 10 New capability for IoT identifiers ..... | 8 |
+| 11 Reference model of identification in the IoT ..... | 8 |
+| Bibliography..... | 10 |
+
+## Introduction
+
+ITU perceives the Internet of things (IoT) as a vision with technological and societal implications that can be viewed as a global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on existing and evolving interoperable information and communication technologies. As a common understanding, the IoT involves various kinds of technologies such as: identification, architectural work, communications, networking, discovery and search engines, power and energy storage and security and privacy. Among these technologies, it is widely agreed that radio frequency identification (RFID), ubiquitous sensor network (USN) or sensor networks and machine-to-machine (M2M) or machine oriented communication (MOC) will be enablers for the IoT.
+
+In RFID environments, tag-based identification [b-ITU-T F.771] enables users to access multimedia information through users' electronic devices equipped with ID tag readers and communication functions. In the IoT environments, it is required to study not only tag-based identification, but also general-purpose identification schemes. Because the IoT involves various enablers such as RFID, USN or sensor networks, and M2M or MOC, the identification scheme of the IoT is required to be applied to these various enablers.
+
+To realize the IoT services, existing information and communication technologies should evolve to support the characteristics of the IoT. Third generation partnership project (3GPP) systems, Internet, wireless local area network (WLAN), wireless personal area network (WPAN), and next generation networks (NGNs) are evolving to provide IoT services based on existing technologies. Due to economic and technical challenges, it is rare to implement completely new technologies. As existing technologies are evolving respectively and independently, the existing identification scheme for each technology will be used continually.
+
+There may be two options for the creation of a future IoT identifier. One is the evolution from existing identifiers, and the other is the creation of a new identifier. Given that information and communication technologies are typically developed with the guarantee of interoperability using existing technologies, a future IoT identifier looks likely to evolve from existing identifiers.
+
+# Recommendation ITU-T F.748.1
+
+# Requirements and common characteristics of the IoT identifier for the IoT services
+
+## 1 Scope
+
+The objective of this Recommendation is to analyse identifiers in existing technologies for the Internet of things (IoT) services, and describe the requirements of the IoT identifier, common characteristics of the IoT identifier, and the reference model of the IoT identifier.
+
+This Recommendation describes the requirements and common characteristics of the IoT identifier for the IoT services. The scope of this Recommendation includes:
+
+- analysis of identifiers in existing technologies,
+- common characteristics of the IoT identifier,
+- requirements of the IoT identifier,
+- reference model of the IoT identifier.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.2060] Recommendation ITU-T Y.2060 (2012), *Overview of the Internet of things*.
+- [ITU-T Y.2063] Recommendation ITU-T Y.2063 (2012), *Framework of the web of things*.
+- [ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 address** [ITU-T Y.2091]: An address is the identifier for a specific termination point and is used for routing to this termination point.
+
+**3.1.2 identifier** [ITU-T Y.2091]: An identifier is a series of digits, characters and symbols or any other form of data used to identify subscriber(s), user(s), network element(s), function(s), network entity(ies) providing services/applications, or other entities (e.g., physical or logical objects). Identifiers can be used for registration or authorization. They can be either public to all networks, shared between a limited number of networks or private to a specific network (private IDs are normally not disclosed to third parties).
+
+**3.1.3 Internet of things** [ITU-T Y.2060]: A global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on, existing and evolving, interoperable information and communication technologies.
+
+NOTE 1 – Through the exploitation of identification, data capture, processing and communication capabilities, the IoT makes full use of things to offer services to all kinds of applications, whilst ensuring that security and privacy requirements are fulfilled.
+
+NOTE 2 – In a broad perspective, the IoT can be perceived as a vision with technological and societal implications.
+
+### **3.2 Terms defined in this Recommendation**
+
+None.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|---------------------------------------------------|
+| 3GPP | Third Generation Partnership Project |
+| CID | Caller ID |
+| DNS | Domain Name System |
+| ETSI | European Telecommunications Standards Institute |
+| FQDN | Fully Qualified Domain Name |
+| HTTP | Hypertext Transfer Protocol |
+| ICTs | Information and Communication Technologies |
+| IEEE | Institute of Electrical and Electronics Engineers |
+| IMEI | International Mobile Equipment Identity |
+| IMSI | International Mobile Subscriber Identity |
+| IoT | Internet of Things |
+| Ipv4 | Internet Protocol version 4 |
+| Ipv6 | Internet Protocol version 6 |
+| ITS | Intelligent Transport Systems |
+| M2M | Machine-to-Machine |
+| MAC | Medium Access Control |
+| MOC | Machine Oriented Communication |
+| MSISDN | Mobile Subscriber ISDN Number |
+| MTC | Machine Type Communication |
+| NGN | Next Generation Network |
+| PDA | Personal Digital Assistant |
+| RFID | Radio Frequency Identification |
+| TCP/IP | Transmission Control Protocol/Internet Protocol |
+| URI | Uniform Resource Identifier |
+| USN | Ubiquitous Sensor Network |
+| WLAN | Wireless Local Area Network |
+| WPAN | Wireless Personal Area Network |
+
+## **5 Conventions**
+
+None.
+
+## **6 Introduction of the IoT identifier**
+
+Information and communication technologies (ICTs) have been used for and by humans, but this situation is evolving. ICTs are being used not only by humans, but also by machines (e.g., things, devices, objects). Specifically, technological environments composed of fixed computers, laptops and high performance machines are evolving to be composed of smartphones, personal digital assistants (PDAs), portable multimedia devices, lightweight devices and sensors. Moreover, all things will be connected to networks as time goes by. This change will be one of the features of IoT.
+
+ICT services are evolving to support the IoT services; as a result, various services such as intelligent transport systems (ITS), smart home services, u-Health, and smart-metering services will converge into the IoT services. Communication and networking technologies such as third generation partnership project (3GPP) systems, Internet, wireless local area network (WLAN), wireless personal area network (WPAN) and next generation network (NGN) are also evolving to provide IoT services based on existing technologies. However, to provide the IoT services, it is necessary to implement completely new services and technologies.
+
+As the existing ICTs services are evolving respectively and independently, the identifier for the existing technologies will be used continually. In the same manner, the future IoT identifier may evolve from the existing identifiers. In 3GPP system-based networks, the mobile subscriber ISDN number (MSISDN), international mobile equipment identity (IMEI), and international mobile subscriber identity (IMSI) are used to provide the IoT services. In the Institute of Electrical and Electronics Engineers (IEEE) 802.11 WLAN-based networks, the medium access control (MAC) address is used as an identifier. In IEEE 802.16 WiMAX-based networks, caller IDs (CID) or MAC addresses are used as an identifier. Each identifier can be used in the same networking technologies, but it is impossible to interoperate with other identifiers used in different networking technologies. If it is required that different identifiers are interoperable in the same manner as the conventional Internet, upper layer identifiers such as Internet protocol version 4 (IPv4), Internet protocol version 6 (IPv6) and uniform resource identifiers (URI) can be used.
+
+If the use of IoT services increases exponentially and globally, new access technologies and new communication networks can be deployed for the IoT services. In this case, a new IoT identifier should be designed and implemented.
+
+Since ICTs are developed with the guarantee of interoperability using existing technologies, then the future IoT identifier looks likely to evolve from the existing identifiers. For interconnection among things (e.g., machines, devices, objects) that are connected to different networks where different identifiers are used, the existing approach of the conventional Internet (interconnection at upper layer using IPv4, IPv6, and URI) or a new approach considering the characteristics of the IoT can be used. For example, a new identifier can be considered to associate the IoT services with devices and vice versa.
+
+In the IoT environment, various ICTs as well as various services and applications should provide for interworking. The existing ICT services and applications have been developed for their own purpose and there is no requirement for them to interconnect with other services and applications. As many things are interconnected and connected to the networks, various services and applications have become interworked. To interwork different services and applications, web-based services and applications have been acknowledged to support this requirement [ITU-T Y.2063]. Whatever the future features of services and applications are in the IoT, the IoT identifier in services and applications will be developed based on the existing identifiers with interoperability.
+
+This Recommendation analyses identifiers in the existing technologies for the IoT services, and describes the requirements of the IoT identifier, common characteristics of the IoT identifier, and the reference model of the IoT identifier.
+
+## **7 Analysis of identifiers in the existing technologies**
+
+This clause describes the existing identifiers in 3G networks and the Internet that can be used in a network for the IoT services.
+
+Both MSISDN and IMSI are used as identifiers in 3G networks; on the other hand, IPv4 and IPv6 addresses, URIs, and fully qualified domain names (FQDNs) are used as identifiers in the Internet.
+
+Each identifier can be used in the same network, but it is impossible to be interoperable with other identifiers used in different networks. If it is required that different identifiers are interoperable, in the same manner as those in the conventional Internet, upper layer identifier such as IPv4 and IPv6 can be used. Considering the characteristics of the IoT, it is certain that the approach used in the conventional Internet is not suitable for the IoT.
+
+In the 3GPP network, identifiers are categorized as follows [b-3GPP 23.003]:
+
+- MSISDN with existing length,
+- MSISDN with max length of 15 digits,
+- IMSI
+
+Although the maximum length of the MSISDN is 15 digits, the currently used length is 12 to 13 digits. The MSISDN with existing length is a globally unique identifier in the 3GPP network and it does not impact the current billing system and authentication scheme in the 3G network. In addition, the MSISDN scheme can represent location information and service information of a device. The MSISDN with existing length can work very well as an identifier scheme in the 3G network. However, the length of the MSISDN is limited; therefore, the MSISDN can lead to a lack of identifiers holding numerous numbers of devices connected to the 3G network [b-3GPP 22.988].
+
+The MSISDN with a maximum length of 15 digits can be used as another identifier in the 3G networks and is a globally unique identifier. In addition, this scheme does not require new standards in 3G networks and can provide a large number of additional MSISDNs. However, if this scheme is used as an identifier of a device in the IoT, it may require changes to existing devices in 3G networks and can have an impact on billing systems.
+
+The IMSI is supported widely in 3G networks and serves as an effective identification scheme to uniquely identify each device. However, it is not suitable for session/call routing identifiers, but rather its primary purpose is for authenticating devices. In addition, the IMSI is not generally accessible when a device is connected through the Internet. Even if the IMSI is used as an identifier of a device in the IoT, the domain name systems (DNS) have to translate the IMSI into an IP address. The IMSI cannot be used as an identifier for billing systems. Thus, modifications to existing billing systems may be required. The IMSI is geographically distributed, but used within a dedicated region. Although the available number of IMSIs is much larger than the number of MSISDNs, the number of devices in the IoT may increase dramatically and consequently lead to insufficient numbers for the IMSI to be used as an identifier.
+
+In the Internet, identifiers are categorized as follows:
+
+- uniform resource identifier,
+- fully qualified domain names,
+- IPv4 address, IPv6 address.
+
+URIs are widely used as generic identifiers. They can be resolved to an IP address by DNS and enable interaction between resources over the Internet using specific protocols (e.g., hypertext transfer
+
+protocol (HTTP)). Thus, if the IoT network infrastructure is realized by existing network technologies, such as conventional transmission control protocol/Internet protocol (TCP/IP) based networks, URIs can be used as a generic identifier of the IoT.
+
+In the conventional Internet environment, the FQDN is a basic domain name scheme and works very well with current IP networks. However, if the FQDN is used as a device identifier in the IoT, the FQDN scheme can be a huge burden on DNS servers. Mapping of every FQDN to an IP address requires an entry in the DNS system. Thus, using the FQDN as an identifier of the IoT devices would increase entries in the DNS system. In addition, this scheme requires additional system updates for authentication and billing in 3G networks. The FQDN scheme has virtually unlimited name space, thus it does not have a limit to the number of identifiers.
+
+IPv4/IPv6 addresses are not suitable as public identifiers because they are used as routing identifiers in the Internet. Although IPv4/IPv6 addresses are generic identifiers, there are not enough of them to accommodate numerous devices in the IoT (i.e., the exhaustion of identifiers can occur).
+
+## 8 Common characteristics of the IoT identifier
+
+Common characteristics of the existing identifiers can be applied to the IoT identifier. Generally, an identifier can be used to identify subscriber, user, network element, function, network entity, or other entity (e.g., physical or logical objects) [ITU-T Y.2091].
+
+In addition to common characteristics of the existing identifiers, the IoT identifier has the following additional characteristics:
+
+- Identifying things:
+An identifier can identify various kinds of things. The existing identifiers identify *specific* things, but the IoT identifiers identify *various* kinds of things. To identify various kinds of things and interconnect things, it is acknowledged that the Internet and the web-based identifiers are more suitable.
+- Communicating with other things:
+After being identified, various types of things can communicate with computers, humans, and other things. With communication between things, things can be interconnected with each other.
+- Connecting to networks:
+Although different communication technologies and services/applications are used, things are connected to networks directly/indirectly and always/periodically/on-demand with identifiers.
+- Huge accommodation:
+Existing identifiers have a limited range of available allocation. The number of the IoT identifiers should be large enough (may be limitless) to cover an enormous number of things.
+- Interconnection:
+Identifiers of things in different networks can be interconnected. Identifiers of physical things in the physical world and identifiers of virtual things in the information world will be interconnected.
+- Diversity:
+Identifiers in the physical world and the information world are different. In the physical world, the identifiers of physical things of the IoT devices may be different according to applied technologies.
+
+- Multiplicity:
+Multiple identifiers may be allocated to a physical thing, a device and a virtual thing. For a specific service and a specific operation, a particular identifier will be selected and utilized.
+- Permanent or limited lifetime:
+Some identifiers that are assigned to things will be either permanent or temporary (i.e., vanish after their time-to-live).
+- Identification of the IoT services:
+Some identifiers can be used to identify the IoT services. When doing this, it is efficient to manage resource and devices in the application layer.
+
+## **9 Requirements of the IoT identifier**
+
+In the IoT environment, a thing is understood as a physical object in the physical world and a virtual object in the information world that is capable of being identified and connected to information and communication networks. The role of an identifier of a thing in the IoT environment is to uniquely identify a physical and a virtual object. An IoT identifier has the requirements listed in the following clauses.
+
+### **9.1 Identifying anything**
+
+**REQ-001:** It is required that identification schemes be able to identify anything.
+
+According to the fundamental characteristics of interconnectivity in [ITU-T Y.2060], anything (physical or virtual, devices or non-devices (do not need communication capabilities)) will be interconnected with the global information and communication infrastructure.
+
+### **9.2 Communication between things**
+
+**REQ-002:** It is required to support the connectivity between things and to provide communication based on identifiers of things.
+
+**REQ-003:** It is recommended to provide a harmonized way to integrate identifiers of devices that need communication capability with identifiers of things that do not need communication capability.
+
+In IoT environments, a thing can be a physical and a virtual object, but some things do not need communication capability.
+
+### **9.3 Association between physical objects and virtual objects**
+
+**REQ-004:** It is required to provide association between a physical object and a virtual object using an identifier.
+
+An identifier in conventional information and communication networks is mainly used to provide connectivity and communication between physical objects. However, an identifier in an IoT environment can be used to provide connectivity and association between physical objects and/or virtual objects.
+
+### **9.4 Networking technology independency**
+
+**REQ-005:** As IoT devices may use different network technologies, identifiers for these IoT devices are recommended to be independent of underlying networking technologies.
+
+In IoT environments, numerous devices will be connected to each other, and those devices may belong to different networks that use different networking technologies. Generally, devices in a network using specific networking technologies can be identified by a specific identifier and/or address used in those networking technologies.
+
+### 9.5 Mapping identifiers to objects
+
+The IoT reference model in [ITU-T Y.2060] is composed of four layers as well as management capabilities and security capabilities associated with the four layers. The four layers are: application layer, service/application support layer, network layer and device layer. From the point of view of an identifier, an identifier in each layer is used to map specific objects (resources) in each layer or one universal identifier can be used to map specific objects (resources) in all layers. Figure 9-1 (a) shows the case where an identifier in each layer is used to map to specific objects in each layer and Figure 9-1 (b) shows the case where one universal identifier is used to map to specific objects in all layers.
+
+
+
+a) An identifier in each layer is used to map to specific objects in each layer
+
+b) One identifier used to map to specific objects in all layers
+
+F.748.1(14)\_F9-1
+
+Figure 9-1: Mapping identifiers to objects. The diagram consists of two parts, (a) and (b), each showing a four-layer IoT reference model. The layers are: Application layer, Service/application support layer, Network layer, and Device layer. To the left of the layers are 'Management capabilities' (Generic and Specific) and to the right are 'Security capabilities' (Generic and Specific). In part (a), each layer has its own identifier (green oval) used to map to specific objects. In part (b), a single 'One universal identifier' (green oval) is used to map to specific objects across all layers.
+
+**Figure 9-1 – Mapping identifiers to objects**
+
+**REQ-006:** In the case where an identifier in each layer is used to map to specific objects in each layer, it is required that each identifier, in each layer, does not directly impact other identifiers in adjacent layers.
+
+When an identifier in each layer is used to map to specific objects in each layer, it is similar to the usage of identifiers in the conventional Internet. For example, in the application layer URIs and FQDNs are used. In the service/application support layer, port numbers and session numbers are used. In the network layer, IPv4 addresses or IPv6 addresses are used. In the device layer, IEEE 802.11 MAC addresses can be used.
+
+**REQ-007:** In the case where one universal identifier is used to map to specific objects in all layers, it is recommended that this one universal identifier efficiently maps to specific objects in each layer and is integrated in a harmonized way.
+
+The case where one universal identifier is used to map to specific objects in all layers is somewhat different from the conventional Internet. One universal identifier may cover all four layers, provide interconnection capabilities between physical objects and virtual objects, and provide simplicity. A universal identifier can be a new identifier with or without interoperability with existing identifiers. Alternatively, one identifier in each layer can be chosen and used as the one universal identifier.
+
+### 9.6 Relation between characteristics and requirements
+
+NOTE – This clause does not define requirements.
+
+In clause 8, common characteristics of IoT identifiers are described. Table 9-1 shows the relation between common characteristics and requirements of the IoT identifiers.
+
+**Table 9-1 – Relation between common characteristics and requirements of IoT identifiers**
+
+| Common characteristics | Requirements |
+|------------------------------------|------------------------------------|
+| Identifying things | REQ-001 |
+| Communicating with other things | REQ-002, REQ-003 |
+| Connecting to networks | REQ-002, REQ-003 |
+| Huge accommodation | REQ-001 |
+| Inter-connection | REQ-002, REQ-003, REQ-004, REQ-005 |
+| Diversity | REQ-004, REQ-005 |
+| Multiplicity | REQ-006 |
+| Permanent or limited life-time | |
+| Identification of the IoT services | |
+
+## 10 New capability for IoT identifiers
+
+As described above, the IoT reference model in [ITU-T Y.2060] is composed of four layers (application, service/application support, network, and device) and two capabilities (management and security). When only considering the IoT identifier in the physical world, the reference model of identification in the IoT is not different from the reference model in [ITU-T Y.2060]. The fact that the IoT identifier should identify devices and physical things in the physical world and virtual things in the information world necessitates a different reference model of identification in the IoT.
+
+In [ITU-T Y.2060] a device, a physical thing and a virtual thing are described as follows:
+
+- A device is a piece of equipment with the mandatory capabilities of communication and the optional capabilities of sensing, actuation, data capture, data storage and data processing.
+- A physical thing is an object of the physical world that is capable of being identified and integrated into the communication networks.
+- A virtual thing is an object of the information world that is capable of being identified and integrated into the communication network.
+
+A physical thing may be represented in the information world via one or more virtual things (mapping), but a virtual thing can exist without an associated physical thing. A device and a physical thing are well identified in the [ITU-T Y.2060] reference model, but it is difficult to identify a virtual thing in that reference model. Therefore, it is required to associate identifiers in the physical world with identifiers in the information world and vice versa.
+
+- Mapping capability: Mapping capability is a particular capability that can be used by two different worlds. Due to the nature of different characteristics of the physical world and the information world, identifiers in each world may be different. This capability associates identifiers in the physical world with identifiers in the information world and vice versa.
+
+## 11 Reference model of identification in the IoT
+
+Figure 11-1 shows a reference model of identification in the IoT where an identifier in each layer is used to identify specific objects in each layer (see clause 9.5). As shown in Figure 11-1, identifiers in each layer in the physical world may be associated with identifiers in the information world. For some specific cases, only related identifiers in the physical world may be associated with identifiers in the information world. In this scenario, mapping capability associates (all or some specific) identifiers in the physical world with the identifier in the information world and vice versa.
+
+Figure 11-2 shows a reference model of identification where one identifier is used to identify specific objects in all layers (see in clause 9.5). As shown in Figure 11-2, one identifier in the physical world
+
+may be associated with identifiers in the information world. In this scenario, mapping capability associates one identifier in the physical world with identifiers in the information world and vice versa.
+
+
+
+Figure 11-1 illustrates the reference model of identification for case (a). The diagram is structured into four layers on the left, each with its own identifier and associated capabilities:
+
+- Application layer:** Contains 'IoT applications' and an 'Identifier in application layer'.
+- Service/application support layer:** Contains 'Generic support capabilities' and 'Specific support capabilities', with an 'Identifier in service/application layer'.
+- Network layer:** Contains 'Networking capabilities' and 'Transport capabilities', with an 'Identifier in network layer'.
+- Device layer:** Contains 'Device capabilities' and 'Gateway capabilities', with an 'Identifier in device layer'.
+
+On the right, a cloud represents the 'Identifier of virtual thing'. A 'Mapping capability' box at the bottom connects the physical world to the information world. Dashed arrows show the mapping from each layer's identifier to the 'Identifier of virtual thing' via the 'Mapping capability'.
+
+Vertical labels on the far left and right categorize these as 'Management capabilities' (Generic and Specific) and 'Security capabilities' (Generic and Specific). The reference F.748.1(14)\_F11-1 is noted at the bottom right.
+
+Figure 11-1: Reference model of identification (case (a)).
+
+**Figure 11-1 – Reference model of identification (case (a) in Figure 9-1)**
+
+
+
+Figure 11-2 illustrates the reference model of identification for case (b). The structure is similar to Figure 11-1, but with a key difference in the identifier model:
+
+- Application layer:** Contains 'IoT applications'.
+- Service/application support layer:** Contains 'Generic support capabilities' and 'Specific support capabilities'.
+- Network layer:** Contains 'Networking capabilities' and 'Transport capabilities'.
+- Device layer:** Contains 'Device capabilities' and 'Gateway capabilities'.
+
+In this case, a single 'One universal identifier' is shown as a large green oval spanning across the Service/application support layer, the Network layer, and the Device layer. The 'Identifier of virtual thing' in the information world is linked to this universal identifier via a 'Mapping capability' box at the bottom.
+
+Vertical labels on the far left and right categorize these as 'Management capabilities' (Generic and Specific) and 'Security capabilities' (Generic and Specific). The reference F.748.1(14)\_F11-2 is noted at the bottom right.
+
+Figure 11-2: Reference model of identification (case (b)).
+
+**Figure 11-2 – Reference model of identification (case (b) in Figure 9-1)**
+
+## Bibliography
+
+- [b-ITU-T F.771] Recommendation ITU-T F.771 (2008), *Service description and requirements for multimedia information access triggered by tag-based identification*; Amendment 1 (2014).
+- [b-3GPP 22.988] 3GPP TR 22.988 v12.2.0 (2012-09), *Study on alternatives to E.164 for Machine-Type Communications (MTC)*.
+- [b-3GPP 23.003] 3GPP TS 23.003 v11.0.0 (2011-12), *Numbering, addressing and identification*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|---------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bd7c24e83d75a6b1baa7fb4210f76345166390c9
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5866ab521163bd4f911ae6e27d0a1cf1f491c665e9b87b7d7076098a143f4bff
+size 3944
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..23a61829d2757e5f1252a9f4eefe0712311fea27
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:765611025e1538c3159e52fbc9272ab4de912d469671e385dd801a60ba1cff4b
+size 22201
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/4356776ca004ecba5d599667a155d7d4_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/4356776ca004ecba5d599667a155d7d4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c251e46de3a3d0e242a528f9f49d79fd00c88185
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/4356776ca004ecba5d599667a155d7d4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:55e7d401e1db0036c5b32076b2c3a8f36973183f2d9ec5efb233a07f16869b29
+size 38682
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..35eb596ce0b4d46b2b029ce3a48a876f729f1ab8
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:91705202e83179ea406f7cc05446fb0c9b8042283fb1b407797ec3861e796c03
+size 25834
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fd7699623f69daa412b8f873420281ec487b6b14
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3e5b93cbb79fe4a305ea5cebe269664d119999a9625f98e37f34a134eab1068c
+size 35628
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..900c357376e3ea0bf244c001bd1c32804618f31f
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:609f2274b106e129c51c531393005a20b51da30a52f42500018189b82c6b715c
+size 35141
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..14f2bbe85e5165cc5405c3f17c1aa5993e9dd579
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5fb45b0b76b8ce87a5e2a8f6dd621afd911051298bac99b88edf2552e3c75a35
+size 17362
diff --git a/marked/Y/T-REC-F.748.3-201511-I_PDF-E/raw.md b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..fcb015dfd61623aa762cda8354dbe557dc5c7670
--- /dev/null
+++ b/marked/Y/T-REC-F.748.3-201511-I_PDF-E/raw.md
@@ -0,0 +1,732 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.4002/F.748.3
+
+(11/2015)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Internet of things and smart cities and communities –
+General
+
+SERIES F: NON-TELEPHONE TELECOMMUNICATION
+SERVICES
+
+# --- **Machine socialization: Relation management models and descriptions**
+
+Recommendation ITU-T Y.4002/F.748.3
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+Y.3000–Y.3499
+
+#### CLOUD COMPUTING
+
+Y.3500–Y.3999
+
+### INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|----------------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.4002/F.748.3
+
+# Machine socialization: Relation management models and descriptions
+
+## Summary
+
+Recommendation ITU-T Y.4002/F.748.3 specifies the relation management models and descriptions for machine socialization which enables machines to cooperate to achieve a given task using their relations with other machines. This Recommendation also includes use cases of relation management models and presents schemas to describe a relation.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.4002/F.748.3 | 2015-11-29 | 16 | 11.1002/1000/12622 |
+
+## Keywords
+
+Machine socialization, relation management model.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2016
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|-----------------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 2 |
+| 6 | Overview of relation for machine socialization..... | 2 |
+| 7 | Relation management models..... | 3 |
+| | 7.1 Centralized relation management model..... | 3 |
+| | 7.2 Distributed relation management model ..... | 4 |
+| | 7.3 Nested-centralized relation management model ..... | 5 |
+| 8 | Relation descriptions ..... | 6 |
+| | 8.1 Machine profile schema ..... | 6 |
+| | 8.2 Relation profile schema ..... | 7 |
+| | Appendix I – Use cases of relation management models ..... | 10 |
+| | I.1 Booking of a movie ticket based on a centralized relation management model..... | 10 |
+| | I.2 Booking of a movie ticket based on a distributed relation management model..... | 11 |
+| | I.3 Booking of a movie ticket based on a nested-centralized relation management model..... | 12 |
+| | Bibliography..... | 14 |
+
+
+
+# Recommendation ITU-T Y.4002/F.748.3
+
+# Machine socialization: Relation management models and descriptions
+
+## 1 Scope
+
+This Recommendation specifies the relation management models and descriptions for machine socialization which enables machines to cooperate to achieve a given task using their relations with other machines. This Recommendation covers the following:
+
+- relation management models for machine socialization;
+- relation descriptions for machine socialization; and
+- use cases for relation management models.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[[ITU-T Y.4001](#)] Recommendation ITU-T Y.4001/F.748.2 (2015), *Machine socialization: Overview and reference model*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 Internet of things (IoT)** [[b-ITU-T Y.4000](#)]: A global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on existing and evolving interoperable information and communication technologies.
+
+NOTE 1 – Through the exploitation of identification, data capture, processing and communication capabilities, the IoT makes full use of things to offer services to all kinds of applications, whilst ensuring that security and privacy requirements are fulfilled.
+
+NOTE 2 – From a broader perspective, the IoT can be perceived as a vision with technological and societal implications.
+
+**3.1.2 machine socialization** [[ITU-T Y.4001](#)]: Enabling things or machines to communicate what they do or what they need to each other as well as to follow each other, discuss with each other and collaborate with each other.
+
+**3.1.3 relation** [[ITU-T Y.4001](#)]: An association between or among machines or things enabling machines or things to share or to provide the capability to achieve a task in collaboration. This includes scheduling of processes between or among machines or things to perform a task.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms.
+
+**3.2.1 capability parameter**: Information on a capability of a machine to achieve a given task such as an input parameter, an output parameter, processing time, etc.
+
+**3.2.2 capability set:** A set of capabilities that machines can provide to process commands from users.
+
+**3.2.3 machine profile schema:** A schema to describe features of a machine.
+
+**3.2.4 relation module:** A module that acts as a relation server in the distributed relation management model. A relation module resides in every machine in the distributed relation management model.
+
+**3.2.5 relation profile schema:** A schema to describe a relation to achieve a given task. It contains information on a group of machines, processing schedules, workgroup IDs, work descriptions and a capability set.
+
+**3.2.6 relation server:** A server to establish a relation and operate machines according to the relations.
+
+**3.2.7 status parameter:** The current status of a machine such as active, standby, expected termination time of the current operation, current execution task, current execution function and expected termination time of the current execution function.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+XML Extensible Markup Language
+
+## **5 Conventions**
+
+None.
+
+## **6 Overview of relation for machine socialization**
+
+Like the human experience of using social network services to obtain information on the knowledge and capabilities of other people, unrestricted by barriers of time and place, etc., machines can communicate what they do or what they need; they can follow each other, discuss, collaborate, create events and do things together. This involves the socialization of machines to a level corresponding to that of the social relations of humans [ITU-T Y.4001].
+
+Socialization may have many meanings, but one of the most important features of socialization is working together. Machine socialization implicates that machines work together to achieve given tasks. To achieve the task in collaboration, machines have to establish associations with other machines by sharing and providing capabilities, these associations are called relations in [ITU-T Y.4001] and in this Recommendation.
+
+In other words, machines should exchange data with other machines and understand the meaning of the exchanged data to establish a relation.
+
+Humans can exchange their ideas with other people using languages or gestures, however a machine cannot exchange information with other machines using natural languages. Therefore, a machine should exchange information and respond to other machines by analysing the information with other machines that is expressed in a mutually understandable form, such as extensible markup language (XML).
+
+This Recommendation defines a schema for a mutually understandable form of machine socialization.
+
+If machines can understand and exchange data with other machines, a relation can be established through relation management.
+
+Relation management establishes a relation, operates machines using the established relation and releases the relation as specified by relation management models.
+
+Procedures to establish a relation vary according to relation management models.
+
+## 7 Relation management models
+
+For machine socialization, it is necessary to manage relations among machines. Relation management varies depending on the relation models. Relation management models may require user intervention in cases where the results of tasks are critical to the user.
+
+In this Recommendation, relation management models define creation and release of relations in three different ways based on the machine socialization framework defined in [\[ITU-T Y.4001\]](#).
+
+### 7.1 Centralized relation management model
+
+
+
+```
+graph TD; M1((M1)) --- RS((Relation server)); M2((M2)) --- RS; M3((M3)) --- RS; M4((M4)) --- RS; User((User)) --- M2; Mn((Mn)) -.- RS;
+```
+
+Diagram of the Centralized relation management model. A central circle labeled 'Relation server' is connected by solid lines to four surrounding circles labeled 'M1', 'M2', 'M3', and 'M4'. A circle labeled 'User' is connected to 'M2' by a solid line. A circle labeled 'Mn' is connected to the 'Relation server' by a dashed line. The diagram is labeled 'Y.4002-F.748.3(15)\_F01' at the bottom right.
+
+**Figure 1 – Centralized relation management model**
+
+In the centralized relation management model shown in Figure 1, a relation server manages relations among machines and executes a task following the steps listed below:
+
+- 1) Machines register machine profile parameters to the relation server.
+- 2) A machine receives a user's command to execute a task and forwards the task to the relation server.
+- 3) The relation server analyses the task.
+- 4) The relation server establishes a capability set to execute the task.
+- 5) The relation server establishes a group of useable machines to execute the task based on the capability set, capability parameters and status parameters of the machines that are already registered on the server or extractable from the target machines.
+- 6) The relation server establishes a relation for the group based on the capability set, the capability parameters and the status parameters of the member machines.
+- 7) The relation includes the group of machines and the schedules of the processes necessary to perform the task.
+- 8) The relation server establishes a relation profile based on the relation.
+- 9) If the results of the processes in the relation profile are critical to the user, the relation server should request a user intervention and update the relation profile:
+ - a) The relation server requests the user to approve the performance of the task or to select processes by listing processes executed by the machines.
+ - b) The user can either approve the performance of the task or select the processes to permit the performance of the task and then notifies the relation server.
+ - c) The relation server may establish a new group of machines and a new relation based on the user's decision.
+
+- d) The relation server establishes a new relation profile.
+- 10) The relation server commands the machines to execute the processes following the schedule of processes included in the relation profile.
+- 11) After completion of the task, the relation server releases the machines from the relation.
+
+### 7.2 Distributed relation management model
+
+
+
+Diagram of the Distributed relation management model showing four machines (M1, M2, M3, M4) and a user. Each machine contains a 'Relation module 1'. M1 and M2 are connected by a solid line. M2 and M3 are connected by a solid line. M3 and M4 are connected by a solid line. M4 and M1 are connected by a solid line. M2 and M4 are connected by a solid line. A 'User' is connected to M2 by a solid line. M2 is also connected to M4 by a dashed line. M4 is connected to Mn (Relation module n) by a dashed line. Mn is connected to M2 by a dashed line. The diagram is labeled Y.4002-F.748.3(15)\_F02.
+
+**Figure 2 – Distributed relation management model**
+
+In the distributed relation management model shown in Figure 2, a relation is established by a relation module that resides in each individual machine. The machine which receives a user's command to perform a task forwards the task to other machines to create a relation. Each machine should determine whether to join the relation or not to execute the task. The machine that received the user's command acts as the coordination machine to create a relation based on the capability sets, capability parameters and status parameters of the group of machines in the relation.
+
+The relation module creates and manages the relation and executes a task following the steps listed below:
+
+- 1) A machine receives a user's command to execute a task from the coordinating machine and forwards the task to the other machines.
+- 2) The relation module in each individual machine analyses the task and makes its own capability set to execute the task.
+- 3) Each relation module decides whether to join the group of machines to execute the task, based on its capability set, capability parameter and status parameter.
+- 4) If a relation module decides to join the group, the relation module shall notify the coordinating machine and send its capability set, capability parameters and status parameters to the coordinating machine.
+- 5) The coordinating machine's relation module creates a relation based on the received capability sets, capability parameters and status parameters of the group of machines.
+- 6) The relation includes the group of machines and the schedule of processes necessary to perform the task.
+- 7) The coordinating relation module creates the relation profile and forwards the relation and the relation profile to the member machines.
+- 8) If the results of processes in the relation profile are critical to the user, the machine that received the user's command should request a user intervention and update the relation profile:
+ - a) The coordinating machine requests the user to approve performance of the task or to select processes by listing processes executed by the machines.
+
+- b) The user can either approve performance of the task or select the processes and then notifies the coordinating machine.
+ - c) The coordinating machine notifies the user's decision to other machines.
+ - d) The relation modules in individual machines make new decisions to join the relation and forward necessary information to the coordinating machine.
+ - e) The coordinating relation module creates a new group of machines and a new relation based on the user's decision.
+ - f) The coordinating relation module establishes a new relation profile.
+- 9) Grouped machines should operate by following the schedule of processes included in the relation profile.
+- 10) After completion of its own task, each machine releases itself from the relation.
+
+### 7.3 Nested-centralized relation management model
+
+The nested-centralized relation management model extends the centralized relation management model.
+
+
+
+```
+
+graph LR
+ User((User)) --- M2((M2))
+ M1((M1)) --- RS((Relation server))
+ M2 --- RS
+ M3((M3)) --- RS
+ M4((M4)) --- RS
+ RS --- SRS((Sub-relation server))
+ SRS --- M5((M5))
+ SRS --- M6((M6))
+ SRS --- M7((M7))
+
+```
+
+Y.4002-F.748.3(15)\_F03
+
+Diagram of the Nested-centralized relation management model showing a central Relation server connected to four machines (M1, M2, M3, M4) and a Sub-relation server. The Sub-relation server is connected to three machines (M5, M6, M7). A User is connected to M2. The Relation server and Sub-relation server are connected to each other.
+
+**Figure 3 – Nested-centralized relation management model**
+
+Figure 3 shows an example of the nested-centralized relation management model where seven machines and two relation servers are involved.
+
+The model manages a relation and executes a task following the steps listed below:
+
+- 1) A machine registers machine profile parameters to either the relation server or to the sub-relation server.
+- 2) A machine receives a user's command to execute a task and forwards the task to the relation server.
+- 3) The relation server forwards the task to the sub-relation server.
+- 4) The relation server and the sub-relation server analyse the task.
+- 5) The relation server and the sub-relation server establish a capability set to execute the task.
+- 6) The relation server and the sub-relation server create a group of useable machines based on the capability set, capability parameters and status parameters of the member machines that are already registered on the server or extractable from the target machines.
+- 7) The sub-relation server establishes a relation of a group of machines and forwards it to the relation server.
+- 8) The relation server establishes a relation using its group of machines and the relation received from the sub-relation server.
+- 9) The relation includes information of the group of machines and the schedule of processes.
+
+- 10) The relation server establishes a relation profile according to the relation.
+- 11) If the results of processes in the relation profile are critical to the user, the relation server should request a user intervention and update the relation profile:
+ - a) The relation server requests the user to approve performance of the task or to select processes by listing processes executed by the machines.
+ - b) The user can either approve the performance of the task or select the processes and then notifies the machine.
+ - c) The relation server may establish a new group of machines and a new relation based on the user's decision.
+ - d) The relation server establishes a new relation profile.
+- 12) The relation server forwards the relation profile to the sub-relation server.
+- 13) The relation server and the sub-relation server command a group of machines to execute processes following the schedule of processes included in the relation profile.
+- 14) After the completion of the task, the relation server and the sub-relation server release the machines from the relation.
+
+## 8 Relation descriptions
+
+The machine profile schema enables the relation server or relation module to mutually understand the features of machines to establish a relation and the relation profile schema stores the relation established.
+
+### 8.1 Machine profile schema
+
+The machine profile schema is a template to describe machines in terms of status, capabilities, IDs, interfaces, etc., which are given in Table 1. A relation is established by a relation server or a relation module with the information inscribed using this profile.
+
+**Table 1 – Machine profile schema**
+
+| Machine profile parameter | Sub-parameter |
+|---------------------------|-------------------------------------------------------------|
+| Status | Active |
+| | Standby |
+| | Current process |
+| | Expected termination time of the current process |
+| | Current function |
+| | Expected termination time of the current execution function |
+| Capability | Name of process |
+| | Input parameter |
+| | Output parameter |
+| | Processing time (duration) |
+| | Processing condition |
+| | Function 1 |
+| | Function 2 |
+| | ..... |
+| | Function n |
+| | End of capability |
+
+**Table 1 – Machine profile schema**
+
+| Machine profile parameter | Sub-parameter |
+|----------------------------------|---------------------------------------------------------|
+| Machine ID | |
+| User ID | |
+| Group ID | |
+| Operating system | |
+| Machine interface | Interface protocol between machines |
+| | Interface parameter between machines |
+| | Interface protocol between machine and relation server |
+| | Interface parameter between machine and relation server |
+| End of machine profile parameter | |
+
+Machine profile parameters are described below:
+
+- Status: Status of a machine indicating active, standby, the expected termination time of the current process, the current execution process, the current execution function and the expected termination time of the current execution function.
+- Capability: Capability of a machine indicating the name of the task, input parameter, output parameter, processing time, processing condition and functions.
+- Machine ID: Alphanumeric identifier of a machine which distinguishes a machine from another machine.
+- Group ID: Alphanumeric identifier of a group of machines in a relation.
+- Operating system: Operating system running on a machine.
+- Machine interface: Communication protocols that a machine can support.
+- End of machine profile parameter: Indicator to specify the end of the machine profile.
+
+### 8.2 Relation profile schema
+
+The relation profile schema shown in Table 2, is a template to describe a relation in terms of capability set, grouped machines, workgroup ID, task description and task processing schedule, etc. After a relation is established, relation information is stored in a relation profile. Tasks to be executed by a relation in machine socialization are expressed in a relation profile and are achieved according to the schedule of processes defined in the relation.
+
+**Table 2 – Relation profile schema**
+
+| Relation profile parameter | Sub-parameter |
+|----------------------------|-----------------------|
+| Capability set | Capability 1 |
+| | ... |
+| | Capability n |
+| | End of capability set |
+| Grouped machines | Machine ID 1 |
+| | .... |
+| | Machine ID n |
+| | End of machine ID |
+
+**Table 2 – Relation profile schema**
+
+| Relation profile parameter | Sub-parameter |
+|-----------------------------------|--------------------------------------|
+| Workgroup ID | |
+| Task description | |
+| Task processing schedule | Process 1 |
+| | Process start time |
+| | Process start condition |
+| | Allotted machine ID |
+| | Start time of function 1 |
+| | Functions 1 |
+| | .... |
+| | Start time of function n |
+| | Function n |
+| | End of functions |
+| | Expected time of process termination |
+| | Interface parameters |
+| | Termination condition |
+| | End of process 1 |
+| | Process 2 |
+| | Process start time |
+| | Process start condition |
+| | Allotted machine ID |
+| | Start time of function 1 |
+| | Functions 1 |
+| | .... |
+| | Start time of function n |
+| | Function n |
+| | End of functions |
+| | Expected time of process termination |
+| | Interface parameters |
+| | Ending condition |
+| | End of process 2 |
+| | ..... |
+| | Process n |
+| | Process start time |
+| | Process start condition |
+| | Allotted machine ID |
+| | Start time of function 1 |
+| | Functions 1 |
+| | .... |
+| | Start time of function n |
+
+**Table 2 – Relation profile schema**
+
+| Relation profile parameter | Sub-parameter |
+|-----------------------------------|--------------------------------------|
+| | Function n |
+| | End of functions |
+| | Expected time of process termination |
+| | Interface parameters |
+| | Termination condition |
+| | End of process n |
+| | End of task processing schedule |
+| End of relation profile parameter | |
+
+Relation profile parameters are described below:
+
+- Capability set: The set of capabilities needed to complete the user's command to perform a task
+- Grouped machines: The group of machines which support the capability set.
+- Workgroup ID: Alphanumeric identifier of the workgroup.
+- Task description: Human readable description of the task implying a user's command.
+- Task processing schedule: Sequence of processes to complete the task.
+- End of relation profile parameter: Indicator to specify the end of relation profile parameter.
+
+## Appendix I
+
+### Use cases of relation management models
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Three use cases of relation management models are introduced.
+
+#### I.1 Booking of a movie ticket based on a centralized relation management model
+
+The use case shown in Figure I.1 illustrates the booking of a movie ticket using a centralized relation management model of machine socialization.
+
+
+
+```
+graph TD; M1((M1
+Movie
+search
+engine)) --- M0((M0
+Relation
+server)); M2((M2
+Smart-
+phone)) --- M0; M3((M3
+Movie
+reservation)) --- M0; M4((M4
+Boiler
+control)) --- M0; User((User)) --- M2;
+```
+
+Y.4002-F.748.3(15)\_FI.1
+
+Diagram of the Centralized relation management model showing a central Relation server (M0) connected to four machines: Movie search engine (M1), Smart-phone (M2), Movie reservation (M3), and Boiler control (M4). A User is connected to the Smart-phone (M2).
+
+**Figure I.1 – Centralized relation management model**
+
+Each machine can perform the following processes:
+
+- M0: M0 manages relations among machines and executes a task.
+- M1: M1 searches movies.
+- M2: M2 receives the user's command to perform a task, booking a movie ticket. It forwards the task to the relation server.
+- M3: M3 books movie tickets.
+- M4: M4 controls the temperature of the house.
+
+A relation is established among M0, M1, M2, M3 and M4 according to the following procedures:
+
+- 1) M1, M3 and M4 have registered their machine profiles including searching capability, booking capability and controlling temperature capability to the relation server respectively.
+- 2) M2 receives a user's command to perform a task and forwards the task to M0.
+- 3) M0 analyses the task and determines a capability set which requires searching for a movie, booking the movie and controlling temperature. Controlling temperature capability will be used to ensure a comfortable environment for a user after watching a movie.
+- 4) M0 creates a group of M1, M3 and M4 including M2 which forwarded the user's commands to M0.
+- 5) With the assumption that the results of this task are not critical, M0 establishes a relation based on the capability set, the capability and the status in machine profiles of M1, M3 and M4 according to the following schedule.
+- 6) Activation of M0, M1, M2, M3 and M4 by using the relation is as follows:
+ - a) M0 sends a command to M1 to search for the specified movie;
+ - b) M1 returns the result to M0 and M0 forwards the result to M2;
+
+- c) The user selects a movie and the selection is forwarded to M3;
+- d) M3 books a movie ticket with the confirmation of the user;
+- e) M0 activates M4 at the time according to the schedule of the process;
+- f) The relation is released.
+
+#### I.2 Booking of a movie ticket based on a distributed relation management model
+
+The use case shown in Figure I.2 illustrates the booking of a movie ticket based on a distributed relation management model for machine socialization.
+
+
+
+Diagram of the Distributed relation model showing four machines (M1, M2, M3, M4) and their relation modules. M1 is a Movie search engine, M2 is a Smartphone, M3 is a Movie search, and M4 is a Boiler control. Each machine contains a relation module. The modules are interconnected: M1's module connects to M2's, M3's, and M4's; M2's module connects to M1's, M3's, and M4's; M3's module connects to M1's, M2's, and M4's; and M4's module connects to M1's, M2's, and M3's. A User is connected to M2's module. The diagram is labeled Y.4002-F.748.3(15)\_F1.2.
+
+**Figure I.2 – Distributed relation model**
+
+Each machine can perform the following processes:
+
+- M1: M1 searches for a movie.
+- M2: M2 is a coordinating machine and receives the user's command to perform a task, booking a movie ticket. It forwards the task to the other machines.
+- M3: M3 books movie tickets.
+- M4: M4 controls the temperature of the house.
+
+A relation is established among M0, M1, M2, M3 and M4 according to the following procedure:
+
+- 1) M2 receives a user's command to perform a task and forwards the task to the M1, M3 and M4.
+- 2) The relation modules in the individual machines analyse the task and establish a capability set to execute the task.
+- 3) The relation modules decide whether to join the group of machines for executing the task coming from the user based on the capability set and its own machine capability parameter and machine status parameter.
+- 4) If the relation module decides to join the relation, it notifies M2 and forwards its capability set, the capability parameters and the status parameters.
+- 5) M2 creates a group of machines, a relation and a relation profile.
+- 6) The relation includes a group of machines and the schedule of processes to perform the task.
+- 7) With the assumption that the results of this task are not critical, the created relation and the relation profile are forwarded to M1, M3 and M4.
+
+Activation of M1, M2, M3 and M4 by using the relation is as follows:
+
+- a) M1 searches for the specified movie according to the relation profile;
+
+- b) M1 returns the result to M2 and M2 forwards the result to the user;
+- c) The user selects a movie and the selection is forwarded to M3;
+- d) M3 books a movie ticket with the confirmation of the user;
+- e) Relation module 4 in M4 activates M4 at the time according to the schedule of processes;
+- f) The relation is released.
+
+#### I.3 Booking of a movie ticket based on a nested-centralized relation management model
+
+The use case shown in Figure I.3 illustrates the booking of a movie ticket based on the nested-centralized relation management model for machine socialization.
+
+
+
+```
+
+graph LR
+ User((User)) --- M2((M2
+Smart-phone))
+ M2 --- M0((M0
+Relation server))
+ M0 --- M1((M1
+Movie search engine))
+ M0 --- M3((M3
+Movie reservation))
+ M0 --- M4((M4
+Boiler control))
+ M0 --- M8((M8
+Sub-relation server))
+ M8 --- M5((M5
+Washing machine))
+ M8 --- M7((M7
+Damp cloth cleaner))
+ M8 --- M6((M6
+Vacuum cleaner))
+
+```
+
+Y.4002-F.748.3(15)\_Fl.3
+
+Figure I.3: Nested-centralized relation management model diagram. The diagram shows a central 'Relation server' (M0) connected to 'Movie search engine' (M1), 'Smart-phone' (M2), 'Movie reservation' (M3), and 'Boiler control' (M4). A 'Sub-relation server' (M8) is connected to 'Relation server' (M0), 'Washing machine' (M5), 'Damp cloth cleaner' (M7), and 'Vacuum cleaner' (M6). A 'User' is connected to 'Smart-phone' (M2).
+
+**Figure I.3 – Nested-centralized relation management model**
+
+Each machine can perform the following processes:
+
+- M0: M0 manages relations among machines and executes a task.
+- M1: M1 searches for movies.
+- M2: M2 receives the user's command to perform a task, booking a movie. It forwards the task to the relation server.
+- M3: M3 books movie tickets.
+- M4: M4 controls the temperature of the house.
+- M5: M5 washes clothes.
+- M6: M6 performs vacuum cleaning.
+- M7: M7 performs damp cloth cleaning.
+- M8: M8 manages relations among submachines and executes a subtask.
+
+A relation is established among M0, M1, M2, M3, M4, M5, M6, M7 and M8 according to the following procedure:
+
+- 1) M1, M2, M3, M4, M5, M6, M7 and M8 respectively have registered their machine profiles including searching capability, booking capability and controlling temperature capability to M0.
+- 2) M2 receives the user's command to perform a task and forwards the task to M0 and M8.
+- 3) M8 server analyses the received task and establishes a relation.
+- 4) M0 analyses the received task and grouping machines which can be used to execute the command by using machine profiles and the generated capability set.
+
+- 5) With the assumption that the results of this task are not critical, a new relation is created in M0 based on the capability set, the capability, the status in other machine profiles and a relation which is generated by a sub-relation server.
+- 6) M0 forwards the new relation profile to M8 server.
+- 7) Activation of M0, M1, M2, M3, M4, M5 and M8 by using the new relation is as follows:
+ - a) M0 sends a command to M1 to search for the specified movie;
+ - b) M1 returns the result to M0 and M0 forwards the result to M2;
+ - c) The user selects a movie and the selection is forwarded to M3;
+ - d) M3 books a movie ticket with the confirmation of the user;
+ - e) M8 activates M5 at the time according to the schedule of the process;
+ - f) The relation is released.
+
+## **Bibliography**
+
+- [b-ITU-T Y.4000] Recommendation ITU-T Y.4000/Y.2060 (2012), *Overview of the Internet of Things*.
+
+## ITU-T F-SERIES RECOMMENDATIONS NON-TELEPHONE TELECOMMUNICATION SERVICES
+
+| | |
+|-----------------------------------------------------------------|--------------------|
+| TELEGRAPH SERVICE | |
+| Operating methods for the international public telegram service | F.1–F.19 |
+| The gentex network | F.20–F.29 |
+| Message switching | F.30–F.39 |
+| The international telemesssage service | F.40–F.58 |
+| The international telex service | F.59–F.89 |
+| Statistics and publications on international telegraph services | F.90–F.99 |
+| Scheduled and leased communication services | F.100–F.104 |
+| Phototelegraph service | F.105–F.109 |
+| MOBILE SERVICE | |
+| Mobile services and multideestination satellite services | F.110–F.159 |
+| TELEMATIC SERVICES | |
+| Public facsimile service | F.160–F.199 |
+| Teletex service | F.200–F.299 |
+| Videotex service | F.300–F.349 |
+| General provisions for telematic services | F.350–F.399 |
+| MESSAGE HANDLING SERVICES | F.400–F.499 |
+| DIRECTORY SERVICES | F.500–F.549 |
+| DOCUMENT COMMUNICATION | |
+| Document communication | F.550–F.579 |
+| Programming communication interfaces | F.580–F.599 |
+| DATA TRANSMISSION SERVICES | F.600–F.699 |
+| AUDIOVISUAL SERVICES | F.700–F.799 |
+| ISDN SERVICES | F.800–F.849 |
+| UNIVERSAL PERSONAL TELECOMMUNICATION | F.850–F.899 |
+| HUMAN FACTORS | F.900–F.999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-F.771-200808-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-F.771-200808-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d5a35041124e73f88d6638cd17f42a2eb4f6781a
--- /dev/null
+++ b/marked/Y/T-REC-F.771-200808-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8f24b214263bab4142643453a604fb5196f9397e2500c675cde79d53ce5e5d8e
+size 3645
diff --git a/marked/Y/T-REC-F.771-200808-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-F.771-200808-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..08ace82cddb65efb98605928cbc0fe3ec05b6701
--- /dev/null
+++ b/marked/Y/T-REC-F.771-200808-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:73b632c4e3ab5ada307b9d0ceea23a732f895212a259bf1419b412fb624e278e
+size 36847
diff --git a/marked/Y/T-REC-H.642.3-201206-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..33e87dccc801e176830fbc855533223e55bf535b
--- /dev/null
+++ b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3ed7565ae48b6fe6d9f9439e4eea0d34a443b150e66f2cc69e5b39f137b940ba
+size 4153
diff --git a/marked/Y/T-REC-H.642.3-201206-I_PDF-E/7f01b16d5b24d18555e9af849c410fbc_img.jpg b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/7f01b16d5b24d18555e9af849c410fbc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..64e98f4cfc285dd27bf76e2d5952bf5097a4f442
--- /dev/null
+++ b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/7f01b16d5b24d18555e9af849c410fbc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:abaa39faa79d05c49e2670cf22aa41db8d3d64e19d3119b06d83f6d27982f855
+size 43219
diff --git a/marked/Y/T-REC-H.642.3-201206-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..07c4391d7f53de06e3bae3ad82365be0b5a4f4ec
--- /dev/null
+++ b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6f95f01706dc08cd85995d0e98f636993602bebf555e567664bb619849173885
+size 65333
diff --git a/marked/Y/T-REC-H.642.3-201206-I_PDF-E/acfc53eca625d62b38aa2563efa95c3e_img.jpg b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/acfc53eca625d62b38aa2563efa95c3e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3d3b81d0cc7ecb6d367370b87919167de74fad4c
--- /dev/null
+++ b/marked/Y/T-REC-H.642.3-201206-I_PDF-E/acfc53eca625d62b38aa2563efa95c3e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:be7585f93ddee8482270e3bb47feb93592e428e2e69a15e4826f30c59ea8f66d
+size 63681
diff --git a/marked/Y/T-REC-L.1601-201606-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg b/marked/Y/T-REC-L.1601-201606-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..41f183bb30776a975621f848995c817fd27f2135
--- /dev/null
+++ b/marked/Y/T-REC-L.1601-201606-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f4cd26eb4b557d5aa9fdc99ed924c3b12cf76b4993c1453f089ee439badf0856
+size 84751
diff --git a/marked/Y/T-REC-L.1601-201606-I_PDF-E/c7753d4f59c41563733ca6a3d256db6d_img.jpg b/marked/Y/T-REC-L.1601-201606-I_PDF-E/c7753d4f59c41563733ca6a3d256db6d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bd7c24e83d75a6b1baa7fb4210f76345166390c9
--- /dev/null
+++ b/marked/Y/T-REC-L.1601-201606-I_PDF-E/c7753d4f59c41563733ca6a3d256db6d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5866ab521163bd4f911ae6e27d0a1cf1f491c665e9b87b7d7076098a143f4bff
+size 3944
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/042733dc5e8e7f5f30b60adba3266cde_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/042733dc5e8e7f5f30b60adba3266cde_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..665fd51799557dc6eb397e7b0a36e668a818efb6
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/042733dc5e8e7f5f30b60adba3266cde_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fdfbaae11adac7ffe5a52f87c95508b40bf5c623dd79d5d8669fc3332d52bcff
+size 33093
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..298e5c50f1f0e6a7d0c9a4f787571f0fea1a3f44
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:09b73cdde94ecb3a3163f7a5ffd88430b786bc5b3f8842aa3f998ae1057a0521
+size 62392
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9f77cbb43d45291b3fef3e17e813aa1065a00a72
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f4992e21c83c059776f9e1260e6ce5859ddd18680b52c30182ad387e56e462d5
+size 59179
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3fbad26a06b450b3e94ef65a019feb76dce09f0d
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:478b1e7f462066533ad73d880c15da87aad47e3abb279ffe90271aa04d1c9268
+size 53466
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/20136850feb70fd71c7d41cdae203ebb_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/20136850feb70fd71c7d41cdae203ebb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a381aaa8a8bf67ceb386fc3913017b305edeb31f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/20136850feb70fd71c7d41cdae203ebb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5f6dfc8fa0fe2006a696971e812e2e21c17aa5d89b204f110d6ae8be7c19a67e
+size 21923
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d5d521fc19ed7a924871b303c6542b18d92809a3
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7dc8b35f96f9903be59fbf078af203b50c61d7f42d0502e4b13dc3da75c61aea
+size 89064
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a69073068ae659d7a121acd662cb7ab071225917
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3f3f5e31d6055bcd4206171e66a30c1e26e2487baa30b03e0b9b01ebb9fe0fce
+size 16136
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..20f973e616c851e54171b87c1ca24446917d4188
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b573e62a803aa0b6c566fefd2d526b93bbbf2e1a95e9cfacfe65dda61b9b134b
+size 19431
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0675320f146212ebd3614281ae0a4abf3588cd7d
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:891ab5fd2d5682d8686d10158dfee305910fc3f601841cedb87aca619ff4fffc
+size 60975
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..29b38d4730a98c33ddd46cb05f461ce85e15faf0
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3ec87868eee021eb2d7409cee7b1cd4ef96cb81cc0779f604e73c740c84249b1
+size 58610
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d5a35041124e73f88d6638cd17f42a2eb4f6781a
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8f24b214263bab4142643453a604fb5196f9397e2500c675cde79d53ce5e5d8e
+size 3645
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..85671627fb7ade0b06a277a5afaf347e699db868
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6401b37fafc4afb5fe4dbe52412e9d3a8ad2d50deb3fbd57abb64de43edd96a1
+size 32298
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cdba2f69fc027f3872ff63729091e7c6e04eedbb
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:03965fa333cfba061498ea0301d31b3c58cffe197724892b3f88f0fbc468e632
+size 16027
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7a2619983ec9c43547b2df021a7b3e6418a16f87
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e5b27f756064c865713dffe655fda3e876249e9f1697a71eee1b071f470a47b2
+size 55324
diff --git a/marked/Y/T-REC-Y.1401-200802-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d81a4acb55e942ce9e36c28de87705727a6cae5c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1401-200802-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:67aca8ba4b047cc81d2b56716ebe9bb502948ab99f539382c2a9ea4bf68b75c4
+size 55408
diff --git a/marked/Y/T-REC-Y.1417-200706-I_PDF-E/9afb9b6f1032f9571efb7260ca75d7cf_img.jpg b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/9afb9b6f1032f9571efb7260ca75d7cf_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..36cf51f8ba07e44aa7a4b009f3ba08eb2b570b1c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/9afb9b6f1032f9571efb7260ca75d7cf_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11780faeee75ba39ab4ed9de67a9e67abec0d9ba3068ebec661dea70c16e29d3
+size 4338
diff --git a/marked/Y/T-REC-Y.1417-200706-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c919d07995d397066d3211ab608586a46e61572e
--- /dev/null
+++ b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2f33fba6f4bb4edb2d684c17775a0c4db7481241f41e0e733a9f356fc927f264
+size 34400
diff --git a/marked/Y/T-REC-Y.1417-200706-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c402d3126441bfda72806eb0d286be4a749b6cc5
--- /dev/null
+++ b/marked/Y/T-REC-Y.1417-200706-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0eafdb3bfc8d82d48c9be823d12960da56c54ea86939bb8f86783b4524bb2c7b
+size 85389
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6f5cc70d2c2cd9ed9146045e13d45f16f6d70cb1
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f8dcf517598b0a25ba247179a9f2b2394f6c158483299ef6500926316f496026
+size 42416
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e00c91b73dbf074ddff1e5afbbe392687ef296ef
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0b3bcac32fce9bb33738c7859c9a313969abb7bcd0a776b75f43a3450590984a
+size 61070
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c75fd0e10f380623ece9b3469855b58a210170ed
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c12abb48a1ae31774e1c6aebfe7ddbf8e71f6f2606f41627de8c2628bfe32d81
+size 116170
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ff005bb1e3f34ccaf3006f44cf1f42153dbb84cc
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:513c30bdd62ba7152c260e2327ee9b2c847477f6b526900061d64c2728c2cfdd
+size 10661
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2d98021debb07032c4e15dc065f1244b3cd2bbf5
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:23bbdfd52d2cbd180b0c6bcc838fc8dc61809dd29567e9c59aaf04ba09214abd
+size 28612
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a3b72f13db64fa956cd6eecdb757ac3a8ddcd597
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:359aaad2cfd94d252d68782662ea82441681ff6603ccfcfd24c3c0c816459fc7
+size 46962
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..24d03995693e546b327663879735bd5e47337a3d
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ec68e317b548b71f49358712a61e0c89ca1a49750db0a79ed6870b4f6834a3c7
+size 62232
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..917a81e8f44663b10fac31579194d20648bd3db3
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1fec63234799b41e254d028a056f095b4e373679ce4420f8e92a15ff575fd667
+size 110855
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..08446e622d1ba65f5e2c010b5b70ced86f5aeda1
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8528522336ed0a2f53ed62b226c0ae31485fb2ea950aad09cfb7364f7be5944b
+size 19794
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f5265a0f8e27a80b54354362acb186643824223c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:823a8a3cb49ab6984b86839afffb3c593b023a8548bf40da102ebcc0e8a858e3
+size 56911
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ed9e6bb3c57241c3dc185c14add7c6dc47ef00d4
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a054de378c7dc034908fbaa6b0f032948e99d58a81abf8f92f3f2cf63489488b
+size 35435
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..88632c154204f67da91984ae4bc7c6d4bacd146f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4a006e6f541012ec09ec506c707d47fbf22a22469942f80690151a7e0af06316
+size 6792
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8a4331203494247ce1a74595c19783f04f69fe7b
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:809279f771528298132ed8de682dbd68e94a63a428fa070e8484f43a7f5c9e54
+size 46751
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1beb073562938aefc82f0d52e54aaea50595f0b8
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c5b6ee3aa6d5d6e19e53a5a9e926289513485ea2b9c704ee0734e3c0712b2e41
+size 57145
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cb0adf713d6a07cad66831dc95d5e52ed40609da
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5996efcc8351287a1d60bdbef0e868eb4a9a8af04373ff50f7b986f553d36bf7
+size 10316
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/b235edb1dbe659e2782c9a0e47775ca4_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/b235edb1dbe659e2782c9a0e47775ca4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a0f7c4aaf6430750e13dea9e69ff36b30c610915
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/b235edb1dbe659e2782c9a0e47775ca4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5cab56add1f3854f68895f5b03e31bc46f2862b047688e1b4f04fe573bc1a2d7
+size 42886
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..33cd861efa4f13466d3fe785b8fd0226fca56611
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c2dd14434b90189fa4efe251ffd01a282b2235b5bdc1c3a75f80476fbbabe334
+size 6428
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..010a9d3d31a43f1b5dc0b5cc9991d6c38450dc17
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cf906e1dfbe32427f7b0891a98c21dbbfab38f0f496f2075aa77e47adf280cc7
+size 83415
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6c42e26b92441da6ff7f394f0e4ab3160a4443c6
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:36dc041d37e3a3e7345fa816564d0176bbc246ac9799e36516e783947cab6204
+size 46962
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/e9314c83043183351ed74908e9bf2f90_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/e9314c83043183351ed74908e9bf2f90_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..82fb2552c8d67197bb62c096e07a0d47589d266a
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/e9314c83043183351ed74908e9bf2f90_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b2ff9caca7e876d072f2a8369f1c93d021af4bdb59fb6ecde80f45f1ade12df3
+size 14658
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f20786b603b41e24b5d5899f710b5947_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f20786b603b41e24b5d5899f710b5947_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..147bb6b6c4ecc787b74af3bf145f5fa599e19c35
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f20786b603b41e24b5d5899f710b5947_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2a523eae445056d39edf9065c61da015a8a50f6cab225db30b47ed44d1eecef7
+size 6730
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f57a881fcbcaf494a7dedc4f61224991_img.jpg b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f57a881fcbcaf494a7dedc4f61224991_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..16fa3e8a8d8c41e44afb09bb2e7f5eb747ae59fb
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/f57a881fcbcaf494a7dedc4f61224991_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bc34aeb870cee9a9508860fc9c765a4fd803d8ac4090be2eff4946c8538be647
+size 6730
diff --git a/marked/Y/T-REC-Y.1530-200711-I_PDF-E/raw.md b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..da681b08114a27a898ed7e80d31e23841de82679
--- /dev/null
+++ b/marked/Y/T-REC-Y.1530-200711-I_PDF-E/raw.md
@@ -0,0 +1,1103 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+**ITU-T**
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+**Y.1530**
+
+(11/2007)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Internet Protocol aspects – Quality of service and network
+performance
+
+# --- **Call processing performance for voice service in hybrid IP networks**
+
+ITU-T Recommendation Y.1530
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with a red lightning bolt striking it, and the text "ITU" in blue, with "International Telecommunication Union" in smaller blue text below it.
+
+ITU logo
+
+## ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# **ITU-T Recommendation Y.1530**
+
+# **Call processing performance for voice service in hybrid IP networks**
+
+## **Summary**
+
+ITU-T Recommendation Y.1530 defines performance parameters and objectives for point-to-point call processing for voice service provided by hybrid IP networks. The parameter definitions are based on the principles and generic performance parameters defined in ITU-T Recommendation I.350, and make use of relevant definitions from ISDN call processing performance Recommendations where appropriate.
+
+###### **Source**
+
+ITU-T Recommendation Y.1530 was approved on 13 November 2007 by ITU-T Study Group 12 (2005-2008) under the ITU-T Recommendation A.8 procedure.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2008
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | | Page |
+|---|----------------------------------------------------------------------------------|-------------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Reference model ..... | 3 |
+| | 5.1 Reference configuration ..... | 3 |
+| | 5.2 Reference events..... | 4 |
+| | 5.3 Performance objectives for delay parameters..... | 4 |
+| | 5.4 Alternate specification of objectives ..... | 4 |
+| 6 | Call processing delays ..... | 4 |
+| | 6.1 Call establishment delays ..... | 5 |
+| | 6.2 Call disengagement delays ..... | 6 |
+| | 6.3 Registration delay (RD)..... | 7 |
+| | 6.4 Deregistration delay (DD) ..... | 8 |
+| 7 | Accuracy and dependability parameters and objectives..... | 8 |
+| | 7.1 Access parameters ..... | 8 |
+| | 7.2 Disengagement parameters..... | 10 |
+| 8 | Security ..... | 11 |
+| | Annex A Call set-up timers..... | 12 |
+| | Appendix I Reference model for TIPHON scenario 2..... | 13 |
+| | Appendix II Measurement methods for estimating VoIP signalling performance ..... | 16 |
+| | II.1 Performance parameters to be measured..... | 16 |
+| | II.2 Measurement architectures..... | 16 |
+| | II.3 Measurement methods using CM/CM architecture..... | 18 |
+| | II.4 Access function VoIP signalling measurement methods ..... | 19 |
+| | II.5 Disengagement function VoIP measurement methods..... | 21 |
+| | Appendix III BICC architecture..... | 23 |
+| | Appendix IV New call processing QoS class structure ..... | 24 |
+| | Bibliography..... | 26 |
+
+
+
+# ITU-T Recommendation Y.1530
+
+# Call processing performance for voice service in hybrid IP networks
+
+# 1 Scope
+
+This Recommendation defines performance parameters and objectives for point-to-point call processing in voice service provided by hybrid IP networks. Call processing delay parameters for ISDN are defined in [ITU-T I.352]. Call processing accuracy and dependability parameters for ISDN are defined in [ITU-T I.359]. The parameters defined in this Recommendation are general in that no particular hybrid IP network call processing protocol is assumed. The protocols used at different signalling interfaces traversed in processing a particular call may differ, and may include (for example) SIP, H.323 and BICC. Call processing protocol events defined in ISDN Recommendations are used for illustration in some cases. Call processing performance measurement architectures are presented in Appendix II.
+
+The parameters defined in this Recommendation are applicable only when the network is available. Assessment of the availability of hybrid IP networks is not addressed in this Recommendation.
+
+Table 1 illustrates the application of the three generic performance criteria defined in [ITU-T I.350] to the call processing functions defined for hybrid IP networks.
+
+**Table 1 – Performance parameters for call processing functions**
+
+| Call processing function | Speed | Accuracy | Dependability |
+|----------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------|---------------------------------------------|-----------------------------------------|
+| 1) Connection set-up | Connection set-up delay Connection post-selection delay (Note 1) Connection answer signal delay (Note 1) | Connection set-up error probability | Connection set-up failure probability |
+| 2) Connection disengagement | Connection disconnect delay Connection release delay (Note 2) | Connection premature disconnect probability | Connection clearing failure probability |
+| NOTE 1 – These parameters are defined for traffic engineering; objectives are not set for network performance. | | | |
+| NOTE 2 – This parameter has local significance only; objectives are not set. | | | |
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T E.671] ITU-T Recommendation E.671 (2000), *Post-selection delay in PSTN/ISDN networks using Internet telephony for a portion of the connection.*
+
+[ITU-T H.225.0] ITU-T Recommendation H.225.0 (2003), *Call signalling protocols and media stream packetization for packet-based multimedia communication systems.*
+
+- [ITU-T H.245] ITU-T Recommendation H.245 (2003), *Control protocol for multimedia communication.*
+- [ITU-T H.323] ITU-T Recommendation H.323 (2003), *Packet-based multimedia communications systems.*
+- [ITU-T H.450.1] ITU-T Recommendation H.450.1 (1998), *Generic functional protocol for the support of supplementary services in H.323.*
+- [ITU-T I.350] ITU-T Recommendation I.350 (1993), *General aspects of quality of service and network performance in digital networks, including ISDNs.*
+- [ITU-T I.352] ITU-T Recommendation I.352 (1993), *Network performance objectives for connection processing delays in an ISDN.*
+- [ITU-T I.359] ITU-T Recommendation I.359 (1999), *Accuracy and dependability of ISDN 64 kbit/s circuit-mode connection types.*
+- [ITU-T Q.764] ITU-T Recommendation Q.764 (1999), *Signalling System No. 7 – ISDN User Part signalling procedures.*
+- [ITU-T Q.931] ITU-T Recommendation Q.931 (1998), *ISDN user-network interface layer 3 specification for basic call control.*
+- [ITU-T Y.1540] ITU-T Recommendation Y.1540 (2002), *Internet protocol data communication service – IP packet transfer and availability performance parameters.*
+
+## 3 Definitions
+
+This Recommendation defines the following terms:
+
+**3.1 end-to-end call processing performance:** Network performance for call processing from UNI to UNI.
+
+**3.2 hybrid IP networks:** Networks in which end-to-end services are provided through interworking between IP-based networks and networks employing other technologies, e.g., PSTN, ISDN, xDSL and CATV.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|---------------------------------------------|
+| ACM | Address Complete Message |
+| ANM | Answer Message |
+| BICC | Bearer Independent Call Control |
+| CASD | Connection Answer Signal Delay |
+| CCFP | Connection Clearing Failure Probability |
+| CDD | Connection Disconnect Delay |
+| CPDP | Connection Premature Disconnect Probability |
+| CPDS | Connection Premature Disconnect Stimulus |
+| CPE | Customer Premises Equipment |
+| CPSD | Connection Post Selection Delay |
+| CRD | Connection Release Delay |
+| CSD | Connection Set-up Delay |
+
+| | |
+|------|---------------------------------------|
+| CSEP | Connection Set-up Error Probability |
+| CSFP | Connection Set-up Failure Probability |
+| DD | Deregistration Delay |
+| FFS | For Further Study |
+| HRX | Hypothetical Reference Connection |
+| IAM | Initial Address Message |
+| ISDN | Integrated Services Digital Network |
+| IWF | InterWorking Function |
+| MP | Measurement Point |
+| MPT | Measurement Point Terminal |
+| RD | Registration Delay |
+| RE | Reference Event |
+| REL | Release |
+| SCN | Switched Circuit Network |
+| SCTP | Stream Control Transmission Protocol |
+| SIP | Session Initiation Protocol |
+| TE | Terminal Equipment |
+| UNI | User-Network Interface |
+| VoIP | Voice over Internet Protocol |
+
+## 5 Reference model
+
+Within the context of this Recommendation, a reference model is intended to establish the context for the definition of performance parameters and the specification of objectives. This reference model provides a baseline reference connection that includes measurement points at which performance-significant reference events are observed and values for call processing performance parameters are determined, and a specification of the traffic loading conditions under which objectives are to be met. This reference model consists of a reference configuration, a set of performance-significant reference events, and time intervals for establishing the conditions under which objectives are to be met.
+
+### 5.1 Reference configuration
+
+The general reference configuration used in describing the call processing performance of voice service provided by hybrid IP networks is illustrated in Figure 1.
+
+
+
+Y.1530(07)\_F01
+
+Figure 1: General reference configuration diagram. It shows a call flow from 'Origination' (represented by a telephone icon) through a 'UNI' (User-Network Interface) labeled 'B\_i' into a central oval labeled 'A network combined with hybrid IP networks'. The call then exits the network through another 'UNI' labeled 'B\_j' to 'Termination' (represented by a computer and telephone icon). Below the termination point, it is noted as '(Ordinary phone or IP phone)'. The diagram is labeled 'Y.1530(07)\_F01' at the bottom right.
+
+**Figure 1 – General reference configuration**
+
+A reference configuration for ISDN/IP networking under TIPHON scenario 2 is described in Appendix I. A reference architecture for BICC is illustrated in Appendix III.
+
+### 5.2 Reference events
+
+The reference events in ISDN can be uniquely specified by [ITU-T I.352] and [ITU-T I.359] based on signalling protocols in [ITU-T Q.931] and [ITU-T Q.764], but the call processing reference events in IP networks depend on the method used for IP telephony, such as H.323, BICC and SIP.
+
+Therefore, the general model of reference events in this Recommendation should be based on a model composed of pairs of portion boundaries ( $B_i$ , $B_j$ ) in Figure 1 and exit and entry events at ( $B_i$ , $B_j$ ) uniquely.
+
+### 5.3 Performance objectives for delay parameters
+
+End-to-end delay parameters are defined using reference events, therefore, performance objectives applied to this set of parameters reflect the quality of service provided by a provider's network.
+
+The performance objectives for the set of delay parameters can be expressed in terms of:
+
+- mean delay; and
+- 95%-ile delay.
+
+However, this approach does not take into account the impact of traffic load on call processing performance parameters (i.e., speed, dependability and accuracy). An alternative worst-case objective is addressed in clause 5.4. Assumptions regarding the call set-up attempt rate are stated in Annex A.
+
+### 5.4 Alternate specification of objectives
+
+In general, while the value taken by a particular call processing performance parameter is sensitive to the traffic load that exists on each portion of the network through which a call is being processed, the worst-case objectives specified in this Recommendation are meant to apply to any one hour of time.
+
+NOTE – To allow for the impact of random, short-term traffic load fluctuations during any hour, the probability that a particular call processing performance parameter value, $V$ , fails to meet its objective, $O$ , may be specified. That is:
+
+$$\text{Prob} \{V > O\} \leq X$$
+
+where:
+
+$V$ = actual parameter value
+
+$O$ = objective
+
+The exact conditions or assumptions under which these worst-case objectives may apply are for further study. Use of an hour or possibly 15-minute interval of time would facilitate support by existing operations systems. It is recognized that the objective would be developed taking into consideration peak traffic factors such as "busy hour".
+
+## 6 Call processing delays
+
+The model for determining call processing delays (see Figure 2) allows for single-portion and between-portion definitions using the reference events. Parameters involving round trip delays (e.g., connection establishment) are defined by portion boundaries (i.e., $B_i$ and $B_j$ below). Unidirectional delay parameters (e.g., connection disconnect delay) are defined only between two portion boundaries. This approach ensures that performance is attributable to specific portions.
+
+For each parameter, performance-significant reference event (RE) tables are provided containing those REs used in the parameter's definition. These REs are listed by relevant boundary. The boundaries are described according to Figure 1.
+
+NOTE – The model and parameter definition regarding call processing delays for SIP and stream control transmission protocol (SCTP) is FFS.
+
+
+
+Y.1530(07)\_F02
+
+Figure 2: Call processing delays. A sequence diagram showing two vertical lines representing boundaries B\_i (left) and B\_j (right). A downward-sloping arrow represents a message flow starting before B\_i, passing through B\_i at event (a) and time t1i, and passing through B\_j at event (b) and time t1j. An upward-sloping arrow represents a return message flow starting after B\_j, passing through B\_j at event (c) and time t2j, and passing through B\_i at event (d) and time t2i.
+
+**Figure 2 – Call processing delays**
+
+### 6.1 Call establishment delays
+
+The boundaries ( $B_i$ and $B_j$ ) from Figure 3 for call establishment delays are measurement points. Figure 3 illustrates aspects of call establishment processing that are observable at measurement points. (a) illustrates set-up at origination and (b) illustrates set-up at termination. (c) illustrates alerting at termination and (d) illustrates alerting at origination. (e) illustrates connect at termination and (f) illustrates connect at origination.
+
+
+
+Y.1530(07)\_F03
+
+Figure 3: Call establishment delays. A sequence diagram with two vertical boundaries B\_i and B\_j. It shows three message flows: 1) A downward-sloping arrow from left to right passing through B\_i at event (a)/time t1i and B\_j at event (b)/time t1j. 2) An upward-sloping arrow from right to left passing through B\_j at event (c)/time t2j and B\_i at event (d)/time t2i. 3) Another upward-sloping arrow from right to left passing through B\_j at event (e)/time t3j and B\_i at event (f)/time t3i.
+
+**Figure 3 – Call establishment delays**
+
+#### 6.1.1 Connection set-up delay (CSD)
+
+Using the notation in Figure 3, the following difference is formed for end-to-end connection set-up delay:
+
+$$\text{CSD} = (t_{3i} - t_{1i}) - (t_{3j} - t_{1j})$$
+
+The worst-case delay objective for CSD, applying to any one-hour period, may be specified as:
+
+**Table 2 – Connection set-up delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | 7500 ms |
+| 95%-ile | 8450 ms |
+
+#### 6.1.2 Connection post selection delay (CPSD)
+
+Using the notation in Figure 3, the following difference is formed for connection post selection delay:
+
+$$\text{CPSD} = (t_{2i} - t_{1i}) - (t_{2j} - t_{1j})$$
+
+The worst-case delay objective for CPSD, applying to any one-hour period, may be specified as:
+
+**Table 3 – Connection post selection delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | 7500 ms |
+| 95%-ile | 8450 ms |
+
+#### 6.1.3 Connection answer signal delay (CASD)
+
+Using the notation in Figure 3, the following difference is formed for end-to-end connection answer signal delay:
+
+$$\text{CASD} = t_{3i} - t_{3j}$$
+
+This double-ended measure is optional.
+
+The worst-case delay objective for CASD, applying to any one-hour period, may be specified as:
+
+**Table 4 – Connection answer signal delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+| 95%-ile | FFS |
+
+### 6.2 Call disengagement delays
+
+Figure 4 illustrates aspects of call disconnect processing that are observable at the measurement points.
+
+The boundaries ( $B_i$ and $B_j$ ) from Figure 4 for call disconnect delays are measurement points. (a) illustrates release at user $i$ (origination). (b) illustrates clearing at user $i$ (origination) and (c) illustrates clearing at user $j$ (termination).
+
+---
+
+1 Provisional values; the actual target values are for further study.
+
+
+
+Figure 4: Call disconnect processing delay diagram. It shows two vertical lines representing boundaries B\_i and B\_j. A line with an arrow labeled (a) enters from the left, hits B\_i at time t1i, and continues to B\_j at time t1j. A line with an arrow labeled (b) enters from the left, hits B\_i at time t2i, and continues to B\_j at time t2i. A line with an arrow labeled (c) enters from the left, hits B\_i at time t1i, and continues to B\_j at time t1j. The diagram illustrates the time difference between the arrival of a call at B\_i and its departure from B\_j.
+
+**Figure 4 – Call disconnect processing delay**
+
+#### 6.2.1 Connection disconnect delay (CDD)
+
+Using the notation in Figure 4, the following difference is formed for connection disconnect delay:
+
+$$\text{CDD} = t1j - t1i$$
+
+The worst-case delay objective for CDD, applying to any one-hour period, may be specified as:
+
+**Table 5 – Connection disconnect delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | 3500 ms |
+| 95%-ile | FFS |
+
+#### 6.2.2 Connection release delay (CRD)
+
+Using the notation in Figure 4, the following difference is formed for connection release delay:
+
+$$\text{CRD} = t2i - t1i$$
+
+As this parameter does not have end-to-end significance, no objectives will be established.
+
+### 6.3 Registration delay (RD)
+
+
+
+Figure 5: Registration delay diagram. It shows two vertical lines representing boundaries B\_i and B\_j. A line with an arrow labeled (a) enters from the left, hits B\_i at time t1i, and continues to B\_j at time t1i. A line with an arrow labeled (b) enters from the left, hits B\_i at time t2i, and continues to B\_j at time t2i. The diagram illustrates the time difference between the arrival of a registration request at B\_i and its acceptance by the network at B\_j.
+
+**Figure 5 – Registration delay**
+
+The boundary ( $B_i$ ) from Figure 5 for registration delay is the measurement point. Figure 5 illustrates aspects of registration processing that are observable at the measurement point. (a) illustrates registration procedure requested by an end user and (b) illustrates registration procedure accepted by the network.
+
+Using the notation in Figure 5, the following difference is formed for registration delay:
+
+$$\text{RD} = t2i - t1i$$
+
+The worst-case delay objective for RD, applying to any one-hour period, may be specified as:
+
+**Table 6 – Registration delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+| 95%-ile | FFS |
+
+### **6.4 Deregistration delay (DD)**
+
+
+
+Figure 6: Deregistration delay diagram. It shows two vertical lines representing boundaries B\_i and B\_j. At boundary B\_i, two events are marked: (a) at time t1i and (b) at time t2i. Event (a) is represented by a line segment sloping downwards to the right, and event (b) is represented by a line segment sloping downwards to the left. Dashed horizontal arrows indicate the times t1i and t2i from the left. Below the diagram is the label Y.1530(07)\_F06.
+
+**Figure 6 – Deregistration delay**
+
+The boundary ( $B_i$ ) from Figure 6 for deregistration delay is the measurement point. Figure 6 illustrates aspects of deregistration processing that are observable at the measurement point. (a) illustrates deregistration procedure requested by an end user and (b) illustrates deregistration procedure accepted by the network.
+
+Using the notation in Figure 6, the following difference is formed for deregistration delay:
+
+$$DD = t2i - t1i$$
+
+The worst-case delay objective for DD, applying to any one-hour period, may be specified as:
+
+**Table 7 – Deregistration delay objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+| 95%-ile | FFS |
+
+## **7 Accuracy and dependability parameters and objectives**
+
+### **7.1 Access parameters**
+
+Two circuit mode access parameters, connection set-up error probability and connection set-up failure probability, are defined in clauses 7.1.1 and 7.1.2.
+
+Connection set-up error and connection set-up failure are defined between pairs of portion boundaries ( $B_i$ , $B_j$ ). $B_j$ is one of the set of boundaries to which the connection set-up attempt can properly be routed. Figure 7 identifies the sequence of four particular events that occur at these boundaries during a successful connection set-up. A connection set-up attempt over this portion is a sequential occurrence of corresponding events [(a), (b), (c), (d)] prior to expiration of timer $T$ . Connection set-up errors and connection set-up failures within this portion are defined below. Any other unsuccessful connection set-up attempt is caused by problems outside the portion and is excluded from the measurement.
+
+NOTE – The model and definition regarding access parameters for SIP and stream control transmission protocol (SCTP) is FFS.
+
+
+
+Y.1530(07)\_F07
+
+Figure 7: Circuit mode reference events occurring during successful connection set-up. The diagram shows two vertical lines representing boundaries B\_i and B\_j. Four arrows represent events: (a) starts at B\_i and points right; (b) starts at B\_i and points right, below (a); (c) starts at B\_j and points left, above (b); (d) starts at B\_j and points left, below (c).
+
+**Figure 7 – Circuit mode reference events occurring during successful connection set-up**
+
+#### 7.1.1 Connection set-up error probability (CSEP)
+
+Connection set-up error probability is the ratio of total connection set-up attempts that result in connection set-up error to the total connection set-up attempts in a population of interest.
+
+With reference to Figure 7, a connection set-up error is defined to occur on any connection set-up attempt in which event (d) occurs, but event (c) does not occur at an appropriate boundary prior to expiration of timer T.
+
+Connection set-up error is essentially the case of a network-caused "wrong number". It occurs when the network responds to a valid connection request by erroneously establishing a connection to a destination terminal equipment (TE) other than the one designated in the connection request, and does not correct the error prior to the user information transfer. It may be caused, for example, by network operator administrative or maintenance actions.
+
+Connection set-up error is distinguished from successful connection set-up by the fact that the intended called user is not contacted and not committed to the session during the connection set-up attempt.
+
+The worst-case objective for CSEP, applying to any one-hour period, may be specified as:
+
+**Table 8 – Connection set-up error probability objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+
+#### 7.1.2 Connection set-up failure probability (CSFP)
+
+Connection set-up failure probability is the ratio of total connection set-up attempts that result in connection set-up failure to the total connection set-up attempts in a population of interest.
+
+With reference to Figure 7, connection set-up failure is defined to occur on any connection set-up attempt in which either one of the following outcomes is observed prior to expiration of timer T:
+
+- both events (b) and (d) do not occur;
+- events (b) and (c) occur, but event (d) does not.
+
+Connection set-up attempts that are cleared by the portion as a result of incorrect performance or non-performance on the part of an entity outside the portion are excluded.
+
+A connection set-up attempt can fail as a result of user blocking. Such failures are excluded from network performance measurement. Examples of user blocking include the following:
+
+- the called user issues a message to reject the call set-up attempt;
+- the CONNect message reference event fails to occur at the originating MPT boundary due to the lack of a CONNect message reference event at the terminating MPT boundary;
+- the called user delays excessively in generating the CONNect message reference event during the connection period, with the result that a connection is not established before the time-out;
+- all channels at the called TE are in use.
+
+The worst-case objective for CSFP, applying to any one-hour period, may be specified as:
+
+**Table 9 – Connection set-up failure probability objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+
+### 7.2 Disengagement parameters
+
+This clause defines two disengagement parameters: connection premature disconnect probability and connection clearing failure probability.
+
+#### 7.2.1 Connection premature disconnect parameters
+
+##### 7.2.1.1 Connection premature disconnect probability (CPDP)
+
+The premature disconnect probability for a portion is the probability, in any given second, that a connection experiences a premature disconnect generated within that portion.
+
+
+
+Figure 8: Circuit mode reference events (REs) defining premature disconnect at B\_i and B\_j. The diagram shows two vertical lines representing boundaries. Line (a) is labeled B\_i and has a diagonal line with an arrow pointing left, indicating a premature disconnect event. Line (b) is labeled B\_j and has a diagonal line with an arrow pointing right, indicating a premature disconnect event. Below the diagram is the text Y.1530(07)\_F08.
+
+**Figure 8 – Circuit mode reference events (REs) defining premature disconnect at $B_i$ and $B_j$**
+
+Referring to Figure 8, a premature disconnect is defined to have been generated within a portion when there is an absence of an external disconnect event (e.g., a premature disconnect stimulus or a disconnect request), or when a connection premature disconnect stimulus occurs within the portion and is transferred across a boundary of the portion.
+
+The worst-case objective for CPDP, applying to any one-hour period, may be specified as:
+
+**Table 10 – Connection premature disconnect probability objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+
+##### **7.2.1.2 Connection premature disconnect stimulus (CPDS)**
+
+The complete definition of premature disconnect stimulus is for further study. However, ten consecutive severely errored seconds is an instance of a premature disconnect stimulus.
+
+#### **7.2.2 Connection clearing failure probability (CCFP)**
+
+Connection clearing failure probability is the ratio of total connection clearing failures to the total connection clearing attempts in a population of interest.
+
+Connection clearing failure is defined with reference to events at the boundaries of a portion ( $B_i$ , $B_j$ ). For example, in the ISDN context, a connection clearing attempt occurs when a DISConnect or RELease message enters the portion creating a reference event at $B_i$ . A connection clearing failure occurs when no corresponding connection clearing reference event occurs at $B_j$ within $T_{ccf}$ seconds.
+
+NOTE – The value of $T_{ccf}$ is for further study.
+
+The worst-case objective for CCFP, applying to any one-hour period, may be specified as:
+
+**Table 11 – Connection clearing failure probability objectives1 **
+
+| Statistic | Objective |
+|-----------|-----------|
+| Mean | FFS |
+
+# **8 Security**
+
+This Recommendation does not specify a protocol. Hence, there are a few areas where security issues may arise, and all are associated with implementation of the performance parameters in measurement systems.
+
+Measurement systems that assess the performance of networks according to the parameter definitions defined in this Recommendation should limit the measurement call and traffic to appropriate levels to avoid abuse. Administrations or operators should agree on acceptable levels of measurement call and traffic in advance.
+
+Systems that monitor user calls and traffic for the purpose of measurement must maintain the confidentiality of user information.
+
+Systems that attempt to make measurements may employ techniques to determine if additional calls and traffic have been inserted by an attacker appearing to be part of the population of interest.
+
+## **Annex A**
+
+## **Call set-up timers**
+
+(This annex forms an integral part of this Recommendation)
+
+While call processing performance parameters in this Recommendation are the same as N-ISDN parameters in [ITU-T I.352], call attempts for voice service in hybrid IP networks may be different from call attempts for N-ISDNs. User terminals for N-ISDNs make point-to-point 64-kbit/s calls, and call processing equipment is seldom overloaded. On the other hand, intelligent user terminals for hybrid IP networks can make many call attempts at a high rate, and these call attempts may degrade the call processing performance by overloading call processing equipment.
+
+Call processing performance, such as connection establishment delay, is determined through measurements defined at the UNI. If TEs make call attempts at a high rate, the call processing performance of call attempts on the UNI will strongly depend on the rate of call attempts from TEs. Thus, specifying conditions for the call attempt rate of the TEs should minimize the impact on call processing performance.
+
+- 1) User terminals do not make any new calls in the interval between a connection request and its complete/incomplete response.
+- 2) The intervals between calls made by a user terminal shall be more than a time interval value T1.
+- 3) Calls considered in this Recommendation are initiated at times when the network is available.
+- 4) The intervals between an incomplete answer and the next call request shall be more than a time interval value T2.
+
+## Appendix I
+
+### Reference model for TIPHON scenario 2
+
+(This appendix does not form an integral part of this Recommendation)
+
+Figure I.1 illustrates a general reference configuration. This reference configuration is based on TIPHON Scenario 2 [b-ETSI TR 101 300]. Table I.1 shows TIPHON inter-network connection cases and scenarios.
+
+
+
+Figure I.1: General reference configuration diagram. The diagram shows a network topology connecting two users. On the left, 'User 1 (ordinary phone)' and 'ISDN CPE (Log. PBX Q.931)' are connected to a 'UNI' (User-Network Interface). This UNI is connected to 'MPT (1)' (Measurement Point Terminal). The network then passes through an 'ISDN' section, then through 'MP (1,2)' (Measurement Point) at an 'IWF' (Interworking Function) interface. The IWF is connected to an 'IP network' (represented by a cloud). The IP network is connected to 'MP (2)' at another 'UNI' interface, which is connected to 'User 2 (Note) (IP phone)'. A '2' is placed below the IWF box. The label 'IP network' is placed above the cloud. The label 'UNI' is placed below the rightmost interface.
+
+Y.1530(07)\_F1.1
+
+NOTE – H.323 terminal
+
+**Figure I.1 – General reference configuration**
+
+**Table I.1 – Inter-network connection cases**
+
+| Case | Origination | Backbone | Termination | Scenario |
+|-----------------------------------------------|-------------|----------|-------------|----------|
+| 1 | IP | IP | IP | 0 |
+| 2 | IP | IP | SCN | 1 |
+| 3 | IP | SCN | SCN | 1 |
+| 4 | IP | SCN | IP | 4 |
+| 5 | SCN | IP | SCN | 3 |
+| 6 | SCN | IP | IP | 2 |
+| 7 | SCN | SCN | IP | 2 |
+| 8 | SCN | SCN | SCN | (Note) |
+| NOTE – Case 8 is outside the scope of TIPHON. | | | | |
+
+Two measurement point terminals (MPTs) are located at an user-network interface (UNI) and an interworking function (IWF) interface of ISDN. Two measurement points (MPs) are located at an UNI and an IWF interface of IP networks. The measurement points in Figure I.1 are identified according to the method established below:
+
+- MPT (1) represents the MPT associated with user 1.
+- MP (1,2) represents the MPT associated with IWF.
+- MP (1,2) represents the MP associated with IWF.
+- MP (2) represents the MP associated with user 2.
+
+An IWF performs all protocol conversions and data adaptations. An IWF device may be used to connect two networks (i.e., a network adaptor) or a terminal to a network (i.e., a terminal adaptor). The IWF provides the following mechanisms:
+
+- Signalling adaptation: This consists of the processing and translation of incoming signalling messages. It mainly concerns the call set-up and clearing phases.
+- Media control: This consists of identifying, processing and translating service-specific control events that may be generated by the user or the terminal.
+- Media adaptation: This consists of adapting the voice data to the data transfer channel of the downstream network.
+
+An IWF consists of a gateway and a gatekeeper. The gateway is responsible for providing all translations necessary for transmission formats and control procedures between the IP-supported portion and the ISDN. The gatekeeper is an optional equipment that provides call control services to the terminals.
+
+Figure I.2-a shows the IWF protocol stacks in the control plane. Figure I.2-b shows the protocol stack needed with the gateway connected as an ISDN node.
+
+Figure I.3 shows call establishment processing delay for voice service in TIPHON scenario 2, and $CSD = D_{1,2} - D_2$ , $CPSD = D_{A1} - D_2$ , $CASD = D_{2,1}$ .
+
+Figure I.4 shows call disconnect processing delay for voice service in TIPHON scenario 2, and $CDD = D_{1,c2}$ , $CRD = D_{1,c}$ .
+
+
+
+The diagram illustrates the functional components, protocols, and measuring boundaries for an IWF in two scenarios:
+
+**a) The IWF appears as an ISDN terminal**
+
+This scenario shows the IWF acting as an ISDN terminal. The protocol stacks are as follows:
+
+- ISDN terminal (MPT 1):** ISDN terminal.
+- ISDN (MP):** ISDN.
+- IWF (gateway) (MP):** IWF (gateway). The IWF signalling adaptation layer is shown. The IWF appears as an ISDN terminal.
+- IP network (MP 1,2):** IP network.
+- IP phone terminal (MPT 2):** IP phone terminal.
+
+The protocol stacks for the IWF and IP network are detailed below:
+
+| Layer | IWF (gateway) | IP network |
+|----------|---------------|------------|
+| Q.931 | Q.931 | Q.931 |
+| Q.921 | Q.921 | TCP |
+| D ch | D ch | IP |
+| Physical | Physical | Physical |
+
+**b) The IWF appears as a network node**
+
+This scenario shows the IWF acting as a network node. The protocol stacks are as follows:
+
+- ISDN terminal (MPT 1):** ISDN terminal.
+- ISDN (MP):** ISDN.
+- IWF (gateway) (MP):** IWF (gateway). The IWF signalling adaptation layer is shown. The IWF appears as a network node.
+- IP network (MP 1,2):** IP network.
+- IP phone terminal (MPT 2):** IP phone terminal.
+
+The protocol stacks for the IWF and IP network are detailed below:
+
+| Layer | IWF (gateway) | IP network |
+|----------|---------------|------------|
+| N-ISUP | N-ISUP | H.225 |
+| MTP 3 | MTP 3 | TCP |
+| MTP 2 | MTP 2 | IP |
+| Physical | Physical | Physical |
+
+Figure I.2: Functional components, protocols and measuring boundaries. The diagram shows two scenarios: (a) The IWF appears as an ISDN terminal, and (b) The IWF appears as a network node. Both scenarios show protocol stacks for ISDN, IWF, and IP networks, with various layers like MTP, Q, D, and Physical layers.
+
+**Figure I.2 – Functional components, protocols and measuring boundaries**
+
+
+
+This sequence diagram illustrates the call establishment process across network domains: ISDN, IWF, and IP networks. The participants are MPT (1), MPT (1,2), Gateway, Gatekeeper, MP (1,2), and MP (2). The process begins with a 'Setup' message from MPT (1) to MPT (1,2). MPT (1,2) sends an 'Initial address message' to the Gateway. The Gateway sends 'Setup' to the Gatekeeper. The Gatekeeper responds with 'Location request', 'Location confirm', 'Admission request', and 'Admission confirm'. The Gateway then sends 'Setup' to MP (1,2). MP (1,2) sends 'Setup' to MP (2). MP (2) responds with 'Call proceeding'. MP (2) sends 'Admission request' to the Gatekeeper, which responds with 'Admission confirm'. MP (2) then sends 'Alerting' and 'Connect' to MP (1,2). MP (1,2) sends 'Alerting' and 'Connect' to the Gateway. The Gateway sends 'Alerting' and 'Connect' to MPT (1,2). MPT (1,2) sends 'Address complete message' and 'Answer message' to MPT (1). MPT (1) sends 'Alerting' and 'Connect' back. An 'H.245 dialogue' occurs between MP (1,2) and MP (2). The diagram defines delay intervals: $D_{1,2}$ , $D_{A1}$ , $D_2$ , and $D_{2,1}$ . The UNI (User Network Interface) is indicated at the bottom for MPT (1) and MP (2).
+
+Sequence diagram for call establishment processing delay in hybrid IP networks.
+
+Y.1530(07)\_FI.3
+
+**Figure I.3 – Call establishment processing delay for voice service in hybrid IP networks**
+
+
+
+This sequence diagram illustrates the call disconnect process across ISDN, IWF, and IP networks. The participants are MPT (1), MPT (1,2), Gateway, Gatekeeper, MP (1,2), and MP (2). The process begins with a 'Release' message from MPT (1) to MPT (1,2). MPT (1,2) sends 'Release' to the Gateway, which sends 'Release' to the Gatekeeper. The Gatekeeper sends 'Release' to MP (1,2), which then sends 'Release' to MP (2). MPT (1,2) also sends 'Release confirm' back to MPT (1). The diagram defines delay intervals: $D_{1,c}$ at the ISDN side and $D_{1,c2}$ at the IP network side. The UNI (User Network Interface) is indicated at the bottom for MPT (1) and MP (2).
+
+Sequence diagram for call disconnect processing delays.
+
+Y.1530(07)\_FI.4
+
+**Figure I.4 – Call disconnect processing delays**
+
+## Appendix II
+
+### Measurement methods for estimating VoIP signalling performance
+
+(This appendix does not form an integral part of this Recommendation)
+
+### II.1 Performance parameters to be measured
+
+The following are the speed of service, accuracy and dependability parameters associated with the transfer of user information:
+
+- Connection set-up delay (CSD).
+- Connection answer signal delay (CASD).
+- Connection set-up failure probability (CSFP).
+- Connection release delay (CRD).
+- Premature disconnect probability (PDP).
+
+### II.2 Measurement architectures
+
+This clause provides an overview of the various architectures that may be used to measure performance parameters for VoIP networks.
+
+A general measurement methodology involves setting up a call to a data sink and generating a known and sufficient quantity of traffic. The protocol and user information signals transferred across the user/network (DTE/DCE) interfaces are observed in real-time and a chronological event history is compiled. This history can then be analysed to provide a measurement of the performance parameters. The measurements of packet-switched networks require a source, a sink and one or more monitors. In the case of measurements over IP connections, the connection, for example a TCP session or RTP session, is to be established and the network is to be configured prior to performing the measurement trial. The source transmits packets over the transport channel. The sink simply receives the packets and performs functions such as call processing. The function of the monitor is to record the relevant reference events. The monitor function should be placed as near as possible to the boundaries of the portions under test.
+
+Sources and sinks can either be controlled or non-controlled. Controlled sources and sinks are under the control of the test program and must respond quickly to events exiting the portions under test. Examples of controlled sources or sinks are stand-alone test equipment, special software within network equipment, and special programs within customer applications. Non-controlled sources and sinks may not always respond quickly to network events. The most important examples of non-controlled sources and sinks are live customer applications, generating and receiving traffic according to their own needs.
+
+A monitor function can be provided by stand-alone test equipment connected at the appropriate IP interface. The monitor function can also reside in the test device that provides the source or sink function.
+
+Various combinations of monitors and controlled and non-controlled sources and sinks can be used to measure VoIP network performance. Figure II.1 shows some of these combinations. The architectures are identified by specifying whether the source and sink are controlled (C) or uncontrolled (N), and whether the two portion boundaries are monitored (M) or unmonitored (U).
+
+
+
+Generic test architecture
+
+Source
+
+Sink
+
+IP connection under test
+
+M
+
+M
+
+C,M/C,M architecture
+
+Controlled source with monitor
+
+Controlled sink with monitor
+
+IP connection under test
+
+C,U/C,M architecture
+
+Controlled source
+
+Controlled source
+
+IP connection under test
+
+M
+
+N,M/N,M architecture
+
+Non-controlled source
+
+Non-controlled sink
+
+IP connection under test
+
+M
+
+M
+
+Y.1530(07)\_FII.1
+
+Figure II.1 – Example test architectures. The diagram shows four horizontal test architectures, each with a central oval labeled 'IP connection under test'. 1. 'Generic test architecture': A triangle labeled 'Source' on the left and a triangle labeled 'Sink' on the right. Both are connected to the central oval. Below each triangle is a square labeled 'M', connected to the line between the triangle and the oval. 2. 'C,M/C,M architecture': A triangle labeled 'Controlled source with monitor' on the left and a triangle labeled 'Controlled sink with monitor' on the right. Both are connected directly to the central oval. 3. 'C,U/C,M architecture': A triangle labeled 'Controlled source' on the left, connected directly to the central oval. On the right, a triangle labeled 'Controlled source' is connected to the line between the oval and a square labeled 'M'. 4. 'N,M/N,M architecture': A triangle labeled 'Non-controlled source' on the left, connected to the line between the oval and a square labeled 'M'. On the right, a triangle labeled 'Non-controlled sink' is connected to the line between the oval and a square labeled 'M'. The label 'Y.1530(07)\_FII.1' is at the bottom right.
+
+**Figure II.1 – Example test architectures**
+
+The possible combinations of controlled and non-controlled sources and sinks and monitored and unmonitored boundaries yield different architectures. Table II.1 shows these architectures with an indication of their ability to measure each parameter.
+
+**Table II.1 – Summary of measurement architectures**
+
+| Measurement Architecture | Performance parameters | | | | |
+|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------|-----------------|-----------------|-----------------|-----------------|
+| | CSD | CASD | CSFP | CRD | PDP |
+| CM/CM | Y | Y | Y | Y | Y |
+| NM/CM | Y | Y | Y | Y | Y |
+| CM/NM | Y | Y | Y | Y | Y |
+| NM/NM | Y 1) | Y 1) | Y 1) | Y 1) | Y 1) |
+| CU/CM | Y | Y | Y | Y | Y |
+| CU/NM | Y 2) | Y 2) | Y 2) | Y 2) | Y 2) |
+| CM/CU | Y | Y | Y | Y | N |
+| NM/CU | Y | Y | Y | Y | N |
+| NM/NU | Y | N | N | N | N |
+| CM/NU | Y | N | N | N | N |
+| NU/NM | N | N | N | N | N |
+| NU/CM | N | N | N | N | N |
+| 1) Assumes the two monitors are synchronized.2) Assumes the user data created by source is known in advance, i.e., assumes that a predetermined Call SeQ. number or equivalent is used at the source, which is known to the sink. | | | | | |
+
+### II.3 Measurement methods using CM/CM architecture
+
+Each performance measurement trial consists of two procedures:
+
+- Data extraction: Packet-layer reference events associated with the trial are created (or observed), time stamped and recorded at the appropriate section boundaries.
+- Data reduction: The recorded reference event histories are processed, consistent with the performance parameter definition, to determine the trial's outcome.
+
+The transport connection should be active and operational on the network portion under test, i.e., the IP service should be in the available state during the entire length of each test. Under certain conditions, the service may be considered unavailable after the performance test is done. This is in the event that any defined minimum performance objectives are not met. Such a criterion may be based on the service availability definition in this Recommendation.
+
+#### Matching packet level reference events
+
+The data reduction procedure requires that all packet level reference events be matched at the two test boundaries. Several alternative methods can be used to do this. A specific pattern of user information data can be used. The data reduction procedure should also be sophisticated enough to recognize lost, errored or extra packets.
+
+### II.4 Access function VoIP signalling measurement methods
+
+#### II.4.1 Data extraction procedure
+
+The data extraction procedure is shown in Figure II.2.
+
+
+
+The diagram illustrates the data extraction procedure for a call establishment trial. It features two main entities: Source and Sink, connected by a 'Network connection under test'.
+
+**Source Process:**
+
+- Start test
+- Compose call setup/reply message packet
+- Transmit IP packet
+Record PE
+- Decision: End of call setup
+ - If No: Loop back to 'Compose call setup/reply message packet'.
+ - If Yes: Record PE end trial.
+
+**Sink Process:**
+
+- Begin recording PEs
+- Received IP packet
+- Compose and send ACK
+- End trial
+
+**Network Connection:**
+
+- A horizontal arrow labeled 'Network connection under test' connects the Source and Sink.
+- Two vertical lines, B1 and B2, represent the communication channels.
+- A dashed arrow from Source to Sink is labeled B1.
+- A dashed arrow from Sink to Source is labeled B2.
+
+Y.1530(07)\_FII.2
+
+Sequence diagram showing the call establishment trial data extraction procedure between Source and Sink.
+
+**Figure II.2 – Call establishment trial data extraction procedure**
+
+#### II.4.2 Data reduction procedure
+
+The data reduction procedure is used to analyse the data collected from the data extraction procedure to calculate the relevant performance parameters for the information transfer over the IP connection. Since it is necessary to ensure that the service availability criterion is satisfied before any performance can be meaningfully evaluated, the data reduction procedure should include necessary computation to help determine if the service is considered available. If the service was deemed available, the call performance statistics can be updated. Figure II.3 shows the steps for the data reduction procedure.
+
+
+
+```
+
+graph TD
+ A[Reset all call performance statistics before trial] --> B[Exclude all measurements taken during periods of service unavailability]
+ B --> C[Perform CASD, CSFP calculations]
+ C --> D[Update cumulative statistics for CSD, CASD and CSFP]
+ D --> E[Done]
+
+```
+
+Y.1530(07)\_FII.3
+
+**Figure II.3 – Call establishment trial data reduction procedure**
+
+Figure II.3 shows the steps for the data reduction procedure. Figures II.4 and II.5 show the procedures for the calculation of CASD and CSD, respectively.
+
+
+
+```
+
+graph TD
+ A[Relate IP packet reference events at the two interfaces] --> B["Denote by T1 the time at which an answer message generated a reference event at B2.
+ And denote by T2 the time at which a corresponding PE at B1 was generated."]
+ B --> C["Compute CASD from T1 and T2"]
+ C --> D[Done]
+
+```
+
+Y.1530(07)\_FII.4
+
+**Figure II.4 – Connection answer signal delay calculations**
+
+
+
+```
+
+graph TD
+ A[Relate IP packet reference events (PRE)
+at the two interfaces] --> B[Denote by $t_1$ the time at which a PRE occurred at B1
+caused by a call setup message and $t_2$ the time at which the
+corresponding PRE occurred at B1 caused by a call setup
+acknowledge message.
+Use the computation $(t_1 - t_2)$ to calculate CSD for this call provided $(t_1 - t_2) \leq T_{max}$ .
+The value for $T_{max}$ is implementation-dependent. $T_{max} < 180$ s]
+ B --> C[Compute CSD]
+ C --> D[Done]
+
+```
+
+Y.1530(07)\_FII.5
+
+Flowchart for VoIP connection set-up delay calculations. It starts with 'Relate IP packet reference events (PRE) at the two interfaces', followed by a box explaining the timing of PREs and the calculation of CSD using (t1 - t2) where t1 is the time of a PRE at B1 caused by a call setup message and t2 is the time of a corresponding PRE at B1 caused by a call setup acknowledge message. It notes that (t1 - t2) ≤ Tmax and Tmax < 180 s. The next step is 'Compute CSD', and the process ends with 'Done'.
+
+**Figure II.5 – VoIP connection set-up delay calculations**
+
+### II.5 Disengagement function VoIP measurement methods
+
+#### II.5.1 Data extraction procedure
+
+The data extraction procedure is shown in Figure II.6.
+
+
+
+```
+
+graph TD
+ subgraph Source
+ S1[Start test] --> S2[Compose call
+release/ACK
+message
+packet]
+ S2 --> S3[Transmit IP
+packet
+record PE]
+ S3 --> S4{End of call
+release}
+ S4 -- No --> S2
+ S4 -- Yes --> S5[Record PE
+end trial]
+ end
+
+ subgraph Sink
+ K1[Begin
+recording
+PEs] --> K2[Received
+IP packet]
+ K2 --> K3[Compose and
+send ACK]
+ K3 --> K4[End trial]
+ end
+
+ S2 <--> N[Network connection
+under test] <--> K1
+
+ %% Interface lines representation
+ B1[B1] --- B2[B2]
+
+```
+
+Y.1530(07)\_FII.6
+
+Sequence diagram for call release trial data extraction procedure. It shows the interaction between a Source and a Sink over a network connection under test. The Source starts the test, composes a call release/ACK message packet, and transmits an IP packet record PE. It then checks for the end of call release. If not, it loops back to composing the packet. If yes, it records the PE and ends the trial. The Sink begins recording PEs, receives the IP packet, composes and sends an ACK, and then ends the trial. Vertical lines B1 and B2 represent the interfaces.
+
+**Figure II.6 – Call release trial data extraction procedure**
+
+#### II.5.2 Data reduction procedure
+
+The data reduction procedure is used to analyse the data collected from the data extraction procedure to calculate the relevant performance parameters for the information transfer over the IP connection. Figure II.7 below shows the steps for the data reduction procedure.
+
+
+
+```
+graph TD;
+ A[Reset all call performance statistics before trial] --> B[Exclude all measurements taken during periods of service unavailability];
+ B --> C[Perform CRD and PDP calculations];
+ C --> D[Update cumulative CRD and PDP statistics];
+ D --> E[Done];
+```
+
+Y.1530(07)\_FII.7
+
+Flowchart of the Call release trial data reduction procedure.
+
+**Figure II.7 – Call release trial data reduction procedure**
+
+Figure II.8 shows the procedure for the calculation of CRD.
+
+
+
+```
+graph TD;
+ A[Relate IP Packet Reference Events PRE at the two interfaces] --> B["Denote by $t_1$ the time at which a PRE caused by a call release message occurred at B1 and $t_2$ the time at which the corresponding PRE caused by a call release ACK message occurred at B2.
+ Use the computation $(t_1 - t_2)$ to calculate CSD for this call provided $(t_1 - t_2) \leq T_{max}$ .
+ The value for $T_{max}$ is implementation-dependent. $T_{max} < 180$ s"];
+ B --> C[Compute CRD];
+ C --> D[Done];
+```
+
+Y.1530(07)\_FII.8
+
+Flowchart of the VoIP connection release delay calculations procedure.
+
+**Figure II.8 – VoIP connection release delay calculations**
+
+## Appendix III
+
+## BICC architecture
+
+(This appendix does not form an integral part of this Recommendation)
+
+An instance of the bearer independent call control (BICC) architecture is shown in Figure III.1. It consists of ATM or IP backbone networks and media gateways (MG) connected to network edge nodes. The role of a MG is to map TDM time slots to ATM cells or IP packets and vice versa. MGs can be either line (local loop) or trunk MGs. Media gateway controllers (MGC) perform call control functions and interact with one or more MGs under their control.
+
+
+
+The diagram illustrates the BICC architecture. At the top, two Media Gateway Controllers (MGC) are connected to a central Signalling network. Below them, two Media Gateways (MG) are connected to the Signalling network via dashed green lines. These MGs are connected to Network edge nodes, which interface with a central ATM or IP network. The Network edge nodes are also connected to PSTN/ISDN networks. On the left side, a CPE (Customer Premises Equipment) is connected to an EO (End Office), which is connected to the PSTN/ISDN. On the right side, a CPE is connected to an EO, which is connected to the PSTN/ISDN. The entire architecture is symmetrical, with the central ATM or IP network acting as the backbone.
+
+Y.1530(07)\_FIII.1
+
+Diagram of BICC architecture showing a central ATM or IP network connected to two sides. Each side has a Media Gateway (MG) connected to a Media Gateway Controller (MGC) via a Signalling network. The MGs are connected to Network edge nodes, which interface with PSTN/ISDN networks. Endpoints (CPE) are connected to the PSTN/ISDN via End Offices (EO).
+
+**Figure III.1 – An instance of BICC architecture**
+
+When MGs are connected to an ATM network, AAL type 1 or AAL type 2 may be used to transport voice services. When MGs are connected to an IP network, RTP over UDP and IP is used. MGs interface to the PSTN with TDM 64 kbit/s channels.
+
+So far, BICC supports ATM networks with AAL type 1 and AAL type 2 and IP networks with RTP/UDP/IP for voice transport.
+
+Current BICC capabilities will remain for some time when the network evolves to the multi-service MPLS network.
+
+In this architecture, UNIs for call processing are defined as UNIs on PSTN/ISDN.
+
+## **Appendix IV**
+
+## **New call processing QoS class structure**
+
+(This appendix does not form an integral part of this Recommendation)
+
+The new call processing QoS class structure with four classes for voice service in IP Hybrid networks to meet varying services is proposed. Call processing QoS classes should be more about definition, requirements, protocols, etc.
+
+Call processing QoS class 1 specifies that all objectives of call processing performance parameters are equal to those specified in [ITU-T I.352] and [ITU-T I.359] about ISDN. This class may be easy to accept for users and for carriers that design some internetworking.
+
+Call processing QoS class 2 specifies that the objectives of connection set-up delay and connection set-up failure probability are more than those specified in ISDN. Other parameters of call processing performance are equal to those of ISDN, specified because the control of these parameters would be difficult and users' concern would be low. This class may be used for some IP telephone networks with internetworking.
+
+Call processing QoS class E specifies that the objectives of connection set-up delay and connection set-up failure probability are less than those specified in ISDN. Other parameters of call processing performance are equal to those of ISDN, specified because the control of these parameters would be difficult and users' concern would be low. This class may supply high or excellent call processing performance for special services. This class should not be used for emergency services defined in ITU-T Rec. Y.1271.
+
+Call processing QoS class U is the unbound (or unspecified) class that all objectives of call processing performance parameters are the unbound (or unspecified). This class may be used for best-effort IP call processing networks with low cost.
+
+Table IV.1 illustrates the new call processing QoS class structure with four classes for voice service in hybrid IP networks.
+
+**Table IV.1 – Call processing QoS class definitions and performance objectives**
+
+| Call processing QoS class | Connection set-up parameters | | | Connection disengagement parameters | |
+|----------------------------------------------------------|------------------------------------------------------|-------------------------------------|-----------------------------------------------|------------------------------------------------------------------|-------------------|
+| | Connection set-up delay | Connection set-up error probability | Connection set-up failure probability | Connection disconnect delay | CPDP CCFP |
+| QoS class E (high or excellent priority level) | Mean < 7500 ms 95%-ile < 8450 ms (FFS) | Default (FFS) | Mean < A (FFS) | Defaults Mean = 3500 ms 95%-ile = 4250 ms [ITU-T I.352] | Defaults (FFS) |
+| QoS class 1 (ordinary telephone level) | Mean = 7500 ms 95%-ile = 8450 ms [ITU-T I.352] | | Mean = A (value A is FFS) [ITU-T I.359] | | |
+| QoS class 2 (IP telephone level) | Mean > 7500 ms 95%-ile > 8450 ms (FFS) | | Mean > A (FFS) | | |
+| QoS class U (best effort level) | U | U | U | U | U |
+| CPDP | Connection Premature Disconnect Probability | | | | |
+| CCFP | Connection Clearing Failure Probability | | | | |
+| U | Unspecified or Unbound | | | | |
+| FFS | For Further Study | | | | |
+
+# Bibliography
+
+- [b-ETSI TIPHON] ETSI TIPHON project,
+<>
+- [b-ETSI TR 101 300] ETSI TR 101 300 V2.1.1 (1999), *Telecommunications and Internet Protocol Harmonization Over Network (TIPHON); Description of Technical Issues*.
+<[http://pda.etsi.org/pda/home.asp?wki\\_id=2vlnbNPXC@5D597V.sJ](http://pda.etsi.org/pda/home.asp?wki_id=2vlnbNPXC@5D597V.sJ)>
+- [b-IETF RFC 1034] IETF RFC 1034 (1987), *Domain names – Concepts and facilities*.
+<>
+- [b-IETF RFC 1349] IETF RFC 1349 (1992), *Type of Service in the Internet Protocol Suite*.
+<>
+- [b-IETF RFC 1889] IETF RFC 1889 (1996), *RTP: A Transport Protocol for Real-Time Applications*.
+<>
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/0a42e05c07941450f34e4f7117725834_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/0a42e05c07941450f34e4f7117725834_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ee0ad77edc705323f4bb30cc042cc0ec598d6d8
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/0a42e05c07941450f34e4f7117725834_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:db69da2ebb3ca947cd50a61020649e21d45d217143380e9d3034011e4dda3309
+size 101880
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/107c8e1abcb7033ad244e30e7a910045_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/107c8e1abcb7033ad244e30e7a910045_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7e6a1fb7549c9024032e0e28aee209b1ec0f900f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/107c8e1abcb7033ad244e30e7a910045_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11149a9769a450d158d4c716295af6a2e88c178f6edc2f27a2b2a99127306343
+size 29938
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/119006c9a930f46881484f2229d3b927_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/119006c9a930f46881484f2229d3b927_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ae337cec2597699f5988418932f01a1ec38f9c5f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/119006c9a930f46881484f2229d3b927_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:16b418464591fe7b8e55a3daf2528a1ff51c272488a4eb1602e758bb0c5743de
+size 55762
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7614fb044bc067806500d1e6ac607f035313cf31
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:823361cd75f3920f759fd3e1ef3e6e6ed51091709da72235eb27aa0f2a50fc66
+size 4135
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6f3af55dc794e18203668e6456d4752a82f2234c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a89da671aad627c1c30e2c8d1a360c3dde115661afe6fca3d6a77d00f4fc8a77
+size 68482
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/201c2ab6f2d9ee6ceabc06b39990b8be_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/201c2ab6f2d9ee6ceabc06b39990b8be_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f8b8c7a3d17f7ad3a49aa4b0d2e7c525db6b109e
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/201c2ab6f2d9ee6ceabc06b39990b8be_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9b0ea528e0353b2a1d57c22b239d029c54ac1ab8b5683b1dff7be66c44154168
+size 79558
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/26f6e6fd981d9bcf4ab4100aebb0400b_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/26f6e6fd981d9bcf4ab4100aebb0400b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0f2488165405d0bea7499ed576b73b8e1596eb94
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/26f6e6fd981d9bcf4ab4100aebb0400b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:293e0a79be0803dac447e10a86a2ad7a88101480f744b843e93f93e86049a5c0
+size 44070
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/37e4831a48bd47b99dcf6837787652ae_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/37e4831a48bd47b99dcf6837787652ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..923534eb33ccab859512b377bb7b01d1d23d2076
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/37e4831a48bd47b99dcf6837787652ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2d7749ad377d14819b7bb3c69c65b82456eccc628f40aeeaaaad8ca24242d7c9
+size 46150
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/3b6177b1edfdc8c7740f03f346d7838f_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/3b6177b1edfdc8c7740f03f346d7838f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ec342c27b43b05a64ddb4250dbb8ec6d7ed46c1
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/3b6177b1edfdc8c7740f03f346d7838f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ac125e7f94e5fac934cd171221e505884aa95573bf2bcfe3a1c5e533bc2c7049
+size 39415
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/4caed5b90277a5c5ee07547bfc8ff884_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/4caed5b90277a5c5ee07547bfc8ff884_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ac039cd821941d7b877666e37666928cc4a3b411
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/4caed5b90277a5c5ee07547bfc8ff884_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4b984fffaa9301fe75bbacb612708ec6082c0bc54c5651e2b8ba5e88def4293e
+size 9144
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c1151b051434fc316153406073ce35dd777ae079
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d42d16a1f0588d4849f0db54e49ff7d9e6c7c6a7c0cfa395307b22f3a67f75d0
+size 56384
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/6a7ea9d5162b0a0cfbd8d77c6cac90d1_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/6a7ea9d5162b0a0cfbd8d77c6cac90d1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1261c30402866c3671dfaefc807b004684fd304f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/6a7ea9d5162b0a0cfbd8d77c6cac90d1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3bdfa29047d8b1e7edb47b25b3d8939dad91ea3d9fa694d940f6b7d12bcd4e51
+size 77895
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/73dff6b45b2b9ffd384bab3235f869af_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/73dff6b45b2b9ffd384bab3235f869af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c1da0f96ab89db1f93daf74274ce9c65153f1109
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/73dff6b45b2b9ffd384bab3235f869af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:25132e9189d3df5520c6b535e390cf9ebc87f276b571a54d291509e4e3ef44c8
+size 24870
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/7f68edb2e500f142fe58f787a7a63c05_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/7f68edb2e500f142fe58f787a7a63c05_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..44acdcd67cfc619abf0927c1c3d00173da0bd330
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/7f68edb2e500f142fe58f787a7a63c05_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2ea9e53c0af307295f4e0de2f2ea83c048ed85e6b7f2f38608c199c9e070d012
+size 91776
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/8afb16b644b2fe89d5c34251c3e6bf0c_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/8afb16b644b2fe89d5c34251c3e6bf0c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c7cd91d43ff356e2702ff069c0818ce9b3838e16
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/8afb16b644b2fe89d5c34251c3e6bf0c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:548a48fe186503bc37b323adbe81dc90b7714ce90b449252503df60b75beaaf7
+size 63054
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/91b12db3c85bbf466ad27eb3665a1b06_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/91b12db3c85bbf466ad27eb3665a1b06_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8e3b02e98bc929a90e52e50d854a75b56e73b727
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/91b12db3c85bbf466ad27eb3665a1b06_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d33d531ff19edb112fa1c8bf695e4e519a2d70b5ea52f75c7da591fcd085cc87
+size 70028
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/97b3ed12d7f6c65cf3f7187326728409_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/97b3ed12d7f6c65cf3f7187326728409_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ed7a50b67e8b0f51b2aa38f344a71cedf906d533
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/97b3ed12d7f6c65cf3f7187326728409_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:69ee527905f4ee042d0911107724d9d9776f3f13c7b4f19e99e980ac5e4302b2
+size 74535
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/99698c448635861b7dc8d352f87a1b2b_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/99698c448635861b7dc8d352f87a1b2b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a0d81e3d782515399f3b8d7b89dcd049e6fe9027
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/99698c448635861b7dc8d352f87a1b2b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1127a36597e224d502907ff0a2387d9cbef70f6870bb450af27df006d716e0e0
+size 82748
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3a2a0b07e9738f167a4d8ef054a2ff46324eefec
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7429ae974f9f341beea77a033042fe5eeca0a742ac15a503b95b641bde62810f
+size 39710
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a149b400127a3e3e50b3c98d27c5935c_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a149b400127a3e3e50b3c98d27c5935c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ef180b90252e0e91099123665096c4c3dc64cb62
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a149b400127a3e3e50b3c98d27c5935c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8f4513ee6e5168cc49e44ff082e468187606faaf96cca1f9ce412b6607dd4bff
+size 70539
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9a4764e9834012a687e5ffd371f3147ac152713b
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:41ff25b188cec45c9daf796d2588c0f2e4f98a593bcf206b53ed61b91e403baf
+size 116295
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a6f9ef297168667527ab18da412f917d_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a6f9ef297168667527ab18da412f917d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f23e4bca8edc4bc9c121e7c84097828e27e0de4c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/a6f9ef297168667527ab18da412f917d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c65edec2230029f518066d7709d131165730a1879a1b526966f2babb75e05923
+size 99197
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..856c70f25eabe0102bbeb6397c09e6d10d275e50
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0b3847f801d167bc1cdde6d778fca41fedfdc45c68b31052b14a96294bc14578
+size 50676
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..00cc7b8288b77e96ffc8dd638dd48b84a0e019f2
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0ed73fbf4079a9bd58dd90af7670fe17ba469da786dac47012b8a168e2a15ed3
+size 98623
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b91520013ba00f460455724c767a470d_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b91520013ba00f460455724c767a470d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5787ad7fbc840cef3c7509fb882b9b6e9cd39603
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/b91520013ba00f460455724c767a470d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:daf9ad5d3faa3780103138e0a40b4c870d8e09250f630a59fa4c0a44c6764a1a
+size 70450
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c51b46bece9e94eff9615851747f31cc_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c51b46bece9e94eff9615851747f31cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f54b657cd90b2157cdc06ff7cc249dde95490ed2
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c51b46bece9e94eff9615851747f31cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:798925330e72fc98fbea422b74a9bef182d9a827a925e0b65191558639b21cd5
+size 66740
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6e185dfe25de96da30ce8cbb1ac54d0824090017
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:95b777bbaf657853d9a5e2d9ce6a177b0e53ea572e897247274b2905a0d62648
+size 69228
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/dd0c2145bef6df0bf52f9ff319cf6713_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/dd0c2145bef6df0bf52f9ff319cf6713_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a8e65b3789cc6278390d6c19333949d16d81e65d
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/dd0c2145bef6df0bf52f9ff319cf6713_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fe232f8751538817f7154e3df6f90b18c5c857f6a76bc2be3ea79b7d232f8c7b
+size 76837
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/e931edfeb30764a64be2a430ccb6f928_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/e931edfeb30764a64be2a430ccb6f928_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..954de88fcca661c81eb5d42a70cdf9b6bf002ed9
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/e931edfeb30764a64be2a430ccb6f928_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:756a2bc93b7c475d7d0262693585bd650088d9aec15e074bedfdb1203f6cc83c
+size 44469
diff --git a/marked/Y/T-REC-Y.1540-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4a9e72e905b61cd9ed103f88735bf39c6fea4aa
--- /dev/null
+++ b/marked/Y/T-REC-Y.1540-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:81115915644299b642dbe0c1636813b8714fd0a9a5d237985700db7e9acf0523
+size 54551
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e629bdd6f3992dfb438a8d0e1cd136d5fc00fd97
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:086129995885179bb7ea8ac359b6a79c4235f2a672bf9106dcb5d4796d2f4b6d
+size 70889
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7bfa83e5b289eaec5f73bb595994968afe15538c
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f82bcfe3d21feb9f296d1d77bc35b1147b9bcd4351aad26446e4785a09090e76
+size 103096
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/58f4167687de8d7339594e5f6fbe0bc6_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/58f4167687de8d7339594e5f6fbe0bc6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9f9637e332669a7b6e86e7c5b9f6c13b0918e746
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/58f4167687de8d7339594e5f6fbe0bc6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e5846b1ca21e21a1ece3f6444aa35bc7d45976fff397234da1f2a260d3418416
+size 105261
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..605056e7d2352e77b6fdc2b2876e0a74a5455f4b
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8a3b4d3bfe54a3c1c5d1d141685878db3714fad147735036131d49e5fbf67289
+size 7464
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c13e7233262f94bd9a789c203358976bb99575f1
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a0739aaf13fa5a632d4faa830f6b2708_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:80b13eecdca6c1b230af64229bc9d972b12ee3f7088e1ede5283175fce38c590
+size 90635
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2ffc43d8442d42ddb7904787ec8ef0e430bfe483
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d30aec2310e202cfab8cfc541c42ddc642ad934014bdddcfe59b748a6cbf9e2e
+size 76362
diff --git a/marked/Y/T-REC-Y.1542-201006-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..983b60577bbefb41a92ae17c9d80fa940847707d
--- /dev/null
+++ b/marked/Y/T-REC-Y.1542-201006-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:48663120be7a81977b3d87d90f2552a15686722f63cfac52e3d4eddcd776c383
+size 73233
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a75d72295db148eea20e568fb68639ac764e600e
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:819244ddaf0b6c0e3ee846a925ed5219d687916760be2039e2b1b06759ba6895
+size 35080
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..56dbe8b561f6cdae6758e42e88b570eb746c9242
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cc9270b580f8b966f9e6fd69a3ee5265443f88162b32d6846aa16ee68ed237e9
+size 64929
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/7bed2d7c96d86bf922295a1252da52a5_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/7bed2d7c96d86bf922295a1252da52a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..678fad78674aeba7f4edb28aef449e6e4dfe113f
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/7bed2d7c96d86bf922295a1252da52a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:12f2820a023012668a10c2144e58a5f011cd46d69fa6dc38c8a5613bc72a867d
+size 41498
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/8791f79b259a7463279c1aeb14c31580_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/8791f79b259a7463279c1aeb14c31580_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4a2aac004b40a81fe1c91a27d602b543e808d804
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/8791f79b259a7463279c1aeb14c31580_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7b1429d7aee0ed6fdfcc4453aba6e6b4063cd5f12bdbd91d78aabd337d5ecd87
+size 36240
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/9b9d2abd741ed4bafe7f78f89961c663_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/9b9d2abd741ed4bafe7f78f89961c663_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5c2a9893ed05e1aca7dfd8d3834b4c11e0109ccc
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/9b9d2abd741ed4bafe7f78f89961c663_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:45f4296b9afc5415854555ba52bdc140f9f036297990870211859eb8f584c525
+size 41998
diff --git a/marked/Y/T-REC-Y.1564-201602-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9676cf7537af4fff527bfccfe6b6ecde851b3f6b
--- /dev/null
+++ b/marked/Y/T-REC-Y.1564-201602-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:40a0973b00a2cb4af42dc0e05ede578de91996dd28e2b449d074842f85b2b982
+size 44605
diff --git a/marked/Y/T-REC-Y.2001-200412-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg b/marked/Y/T-REC-Y.2001-200412-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e05c419a062f684999237f2489a05a1d0b57a7ff
--- /dev/null
+++ b/marked/Y/T-REC-Y.2001-200412-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b6dba59c9471e18d015d9a48b31c19ae9bc59f7043cca91d738bc9d39ec6378c
+size 6065
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e05c419a062f684999237f2489a05a1d0b57a7ff
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/2dfa6ac3edfe874f68aa0cbccaa42322_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b6dba59c9471e18d015d9a48b31c19ae9bc59f7043cca91d738bc9d39ec6378c
+size 6065
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d756091b135f679926f41fedca274b99728950d0
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:02663fd4ebe87b2e8128572f1233431a447a3441bf914b0b809e90773b3e8ee5
+size 82525
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d3ea76cae02cdb0764605478ea53be43472a877c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a1cf0538d0c078da9b8df44c203b53e725963525a0b7cc08bacd3a25e048e7b2
+size 37292
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7d2d1d3870cd224c4430d19334557716_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7d2d1d3870cd224c4430d19334557716_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e8a9ddfe8d0583794157eb24b3638e1cd2775b95
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7d2d1d3870cd224c4430d19334557716_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0366df3ad2f410bd1057d45597e805d205851a0f5fe1ad22838e48e0f20067ec
+size 32901
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..efbeb71a7eb178fb43e45f06b2d819276916573e
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e091d606211b17c1014b8f723bcbf0c0cfddd2c351b7983fb4907a5578d85008
+size 41409
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/98e54d5540b2efe3e24af3cf936bc4ea_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/98e54d5540b2efe3e24af3cf936bc4ea_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9aaaa00f87cef0c08df636950d6642f920b13b89
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/98e54d5540b2efe3e24af3cf936bc4ea_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:33c253481fdd20f67f4e96ea2a721d528ddc15e89ee95f2de83dd49369d61957
+size 27872
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9b6b5924b48bf2fd5f347f88f06f45b3_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9b6b5924b48bf2fd5f347f88f06f45b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c9e9bc6a78dca24a80cf30067229086284d44492
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9b6b5924b48bf2fd5f347f88f06f45b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:120895099e1d88fda4cb9a2aca05f9769bfd8f2e9bd3c8d56a89d83c1ecead70
+size 87895
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ae91381343653ddf40b758608a5a0c9cba2f9e31
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d0bf3a706842982bf07619fb52a04c9b1465dfb4f373102b0212b548d03a910f
+size 81437
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..72093d9cda1ee932112a0e00283b15f65e9baf24
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:816d7905953a0be0f244f3b3d648b7543127913629b51daa48520088db7d0a0d
+size 142394
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..59593014a95622bce80209d4e5a6337cda2c8704
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bb89f919f1ac3175725765729db7cb379c4a5775eea3cc5fb232962811b969f1
+size 56769
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..55ee4e653c08b7eed40c4249086ca050d3110132
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:649f569ba6f29ad41768d27a907ed19707bf3998bc6467054242ef24489e6098
+size 74267
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2a0c954cf2ade56e65ac132f4e0ba3c9e3112889
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:615df768290c6d42ebc3d37a129c2e774fd05de5b8bbdfdd66da5f51e8b01bc5
+size 54417
diff --git a/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e9d825d87c5f85c8dba0664eace96ef4_img.jpg b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e9d825d87c5f85c8dba0664eace96ef4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..02d5e43655c59dba88afdd3f29dbc653a6d443aa
--- /dev/null
+++ b/marked/Y/T-REC-Y.2011-200410-I_PDF-E/e9d825d87c5f85c8dba0664eace96ef4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6d7d843886e05922342b583f4670528ec7c8d2d8e476fcb884d3356621f6f565
+size 43138
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/02d0c8a07c481d880b73a25d02050fad_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/02d0c8a07c481d880b73a25d02050fad_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2955cd978efecac70c1777b68f2f13a63ede2399
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/02d0c8a07c481d880b73a25d02050fad_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7d5b5ba2e95c428c81c231797b2360488ab9f908fbf051aef50814a8cc699080
+size 12175
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c2cac7ccf453e8f80f88d7d983cbefd09f026498
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e1d4868e0ec0f6f934e702b37629dd17d547373b9cabe0efa86ca154c42b9c96
+size 77772
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a73e295724298d493986932bd7fd120b4232983d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a1addb9dbdb737b0d7ff19980b3fca35d4d973c49afb3c06d50508751c78c657
+size 32040
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/1ad662a678c4f002de911d403f00de8e_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/1ad662a678c4f002de911d403f00de8e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ebcc62942a37eca1a3756815039ae97472a5da83
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/1ad662a678c4f002de911d403f00de8e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:956da6a8664ffba6d8bd540754704bd4e47bbb080ae8cd62793189bb50baf908
+size 11737
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/24c9e038a791677ed33100667b64f7e6_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/24c9e038a791677ed33100667b64f7e6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ed9cd31b11d376f53a074f409d3d183cc1dde00
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/24c9e038a791677ed33100667b64f7e6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:234bc551d8ad2de6b3a4b7a4b318e734ba8fdb028392c43ba490ff09b04f76b6
+size 82889
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4bae6a4e008226d8469bc233358cdc705c9cc55e
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2b949fb1e5dc3f56202cbf6796f91dc854bfe464b73f5a470e8e1f2bf4f295dd
+size 4366
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/382a9c9e4816bd229191ab4591424dd8_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/382a9c9e4816bd229191ab4591424dd8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..622fead91aef1afc72a2a2b3f7103425d6f714af
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/382a9c9e4816bd229191ab4591424dd8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d69c3701f081fa1fac9828b48a2db40601dfd6d2407a51614db338c04c321b61
+size 20464
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/3ad00ce93ad9dea9ee0f47535e5355e6_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/3ad00ce93ad9dea9ee0f47535e5355e6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f4f25ce4e4bf033533cb8ce72ccedc21f4450863
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/3ad00ce93ad9dea9ee0f47535e5355e6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a9b958aadcac33c15206c07af1300c0fa10d037c0d22f1e738195070bfaf89a5
+size 80210
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4accfd27a304f7752389e86570129ce088075b4f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:07a9e7103fe97d2a99a50a495655670a522cc22e59ccd604fb7826f64e2dca5e
+size 65324
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ac70c57f01fab1dc4b0210979fe6d642f8f61d15
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:becda55d67aceace4f7235552404735afdb49eda39112727ba680109360ec759
+size 16024
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/692541e65db4dc852988ce77ebb60ce5_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/692541e65db4dc852988ce77ebb60ce5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8d0c2fefd6da44fdcc2fb95eff7bc91ce053e459
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/692541e65db4dc852988ce77ebb60ce5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:36165d879a160e682fc5f0ca1f16bcbb76a641e60b177b3805464da953e56bfa
+size 96912
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..139752eadbae845677b5f0a0be597b5f49e939b7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7b10cf0cb803ef109452510f36f132918a006ea2338923cefc3b4ae834a55ad3
+size 89636
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b8dd4428ab1cc3ee7862995dcbf54201baa1dd81
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:db729980318805f1eb0ece4b3296bcb99f1cc8eba619b9452b0ed4eaeb1ac914
+size 75721
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..965074cc5813d6db2e16012b743bc8116dc31dd1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b09691062fb7b8ed3d46e6b1cc16dfbd2e3d86472eeba57fad77f733e6a28fb3
+size 16395
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..83de44cfa91ff96cd6d044185230bbdca1aff85e
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:92c3c68bcdb95caa413d3d9a4747655489556a99ef57b3def4ad289d99ef7337
+size 6615
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..64816a6d2a8ea9acc633edbd87c9b70393f57b68
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8e9e1e42e43a2573119d105f24794f0afa8ca52d7b6c7a0810f6d6aca35fbee7
+size 70624
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..effe51eb602f9218cb4819bc939bad2c71efa5f9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:466816003a34f5072ac5f5065ec44076148c76168d2bc7e688b0ea1e1dbd68b8
+size 310754
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c8fcefd2b1fa5b1b7afaf87ab5601389089028cd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8d31283a9fdf43935c37110407a6cb631724502badde8745ce5919d1acf2f43a
+size 3595
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f6204f2ae4dfe691f1246e4d40e79694aa616783
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:595602d09a8d87cb66aba29c5705a08ae3ef1124d6dce94cc6009a22d04f5cf7
+size 16788
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/bb3354f497635d15bef873577125c48d_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/bb3354f497635d15bef873577125c48d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..59457bc7c405fcb2d057fbd40465c1781ecd9e06
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/bb3354f497635d15bef873577125c48d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:08bc6f9889e0c38c328e3eef2b37e7f7c4eb122980ab32d0778b10541e241a94
+size 51569
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..789cfa92300a88d8bfc4ef4e9b7903b5e5940d1f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a5185951ccbfcae4a7f1e33c6f23a2e9958235f491cc8cebdb222c9ad8d8f3ab
+size 20434
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/cf4ac1058c52bc3ca37737740afb7f2c_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/cf4ac1058c52bc3ca37737740afb7f2c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..243011bc1f4445e0cb86a642bf6168d25c9cbfdc
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/cf4ac1058c52bc3ca37737740afb7f2c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e2e52bc2d232a2446dc4486a9afda1b7f8e0b1f7fe173419ae06cd731e48698c
+size 47387
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/dbbc0baac7341cda76cc4f8355dce23f_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/dbbc0baac7341cda76cc4f8355dce23f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d26507d697e8221c7d6e9bde9ccce12c71cfad9a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/dbbc0baac7341cda76cc4f8355dce23f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:80fb7a587c4472f27a20dccabe06a4569139c7eae1203decbf7fb1ed11033572
+size 72406
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a578536dc8893568b7c89458b6e4a33cf741caf1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bf1bdbaa88089fc054e4e0f8f12f0d3167bc53a63743235a1dd394006b118044
+size 28904
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e90987faabad6a6665cd8ed1151dc474_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e90987faabad6a6665cd8ed1151dc474_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5710082b79d1bdaf8e73bfab9fa53ad7f0a01ac8
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/e90987faabad6a6665cd8ed1151dc474_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9a743833239e4d2f8a380c474ba1447256c2e67f29271fd83d7f8cf09db11edd
+size 87950
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e21d181c7b817eb48f02f1c62f0bc84fa36b0f88
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:301adae697d5df5586ede76be694967a7d31ea9cdeca6e82c0f61a18447caf02
+size 98738
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f9c64800d9bace9b4315646d1057be3c_img.jpg b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f9c64800d9bace9b4315646d1057be3c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..672764643d287f0256bca05dfa22e43e13bb5d7c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/f9c64800d9bace9b4315646d1057be3c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3947a5632b4a766c595ab0d79b1bfd61cbd597f3de6ec1cfdb923fe0c7bf3b20
+size 122514
diff --git a/marked/Y/T-REC-Y.2019-201009-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..4147d7703d91ffde2e6ce14cc43f483a52091f31
--- /dev/null
+++ b/marked/Y/T-REC-Y.2019-201009-I_PDF-E/raw.md
@@ -0,0 +1,1610 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.2019
+
+(09/2010)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Frameworks and functional
+architecture models
+
+# --- **Content delivery functional architecture in NGN**
+
+Recommendation ITU-T Y.2019
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with two red lightning bolts striking it. To the right of the globe, the text 'ITU' is written in a large, bold, blue font, and below it, the words 'International Telecommunication Union' are written in a smaller, blue font.
+
+ITU logo: a globe with red lightning bolts and the text 'ITU International Telecommunication Union'
+
+# ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Future networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# **Recommendation ITU-T Y.2019**
+
+# **Content delivery functional architecture in NGN**
+
+# **Summary**
+
+Recommendation ITU-T Y.2019 describes the content delivery functional architecture in NGN. This detailed architecture is based on the IPTV functional architecture described in Recommendation ITU-T Y.1910. Only the NGN architecture options (IMS and non-IMS) are addressed.
+
+## **History**
+
+| Edition | Recommendation | Approval | Study Group |
+|---------|----------------|------------|-------------|
+| 1.0 | ITU-T Y.2019 | 2010-09-06 | 13 |
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2011
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | | Page |
+|----|--------------------------------------------------------------|------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | Content delivery overview..... | 3 |
+| | 6.1 Introduction ..... | 3 |
+| | 6.2 Content ingestion..... | 5 |
+| | 6.3 Content dispatching ..... | 5 |
+| | 6.4 Content delivery ..... | 5 |
+| 7 | Content delivery functions..... | 6 |
+| | 7.1 Content delivery functions in the IPTV architecture..... | 6 |
+| | 7.2 Hierarchical content delivery architecture..... | 8 |
+| 8 | Content delivery requirements..... | 9 |
+| | 8.1 Mandatory requirements..... | 9 |
+| | 8.2 Optional requirements ..... | 10 |
+| 9 | Reference points ..... | 10 |
+| | 9.1 Reference point D1' between CD&LCF and CCF ..... | 10 |
+| | 9.2 Reference point D2 between CCF and CDPF ..... | 10 |
+| | 9.3 Reference point D3 between different CD&LCF..... | 11 |
+| | 9.4 Reference point D4 between different CCF ..... | 11 |
+| | 9.5 Reference point D5 between different CDPF..... | 11 |
+| | 9.6 Reference point S1' between SCF and CCF ..... | 11 |
+| 10 | Hierarchical model deployment principles..... | 11 |
+| | 10.1 General principles..... | 11 |
+| | 10.2 Selection ..... | 12 |
+| 11 | Content delivery procedures..... | 13 |
+| | 11.1 Generic content delivery procedures..... | 13 |
+| | 11.2 Hierarchical content delivery procedures..... | 13 |
+| 12 | Security considerations ..... | 30 |
+| | Appendix I – Deployment model..... | 31 |
+| | I.1 Delivery deployment model ..... | 31 |
+| | I.2 Client/server model ..... | 31 |
+| | I.3 Proxy instance model ..... | 32 |
+| | I.4 Hybrid model..... | 32 |
+
+# **Introduction**
+
+The key aspects of content delivery are to locate content delivery instances in the NGN and to provide delivery of content to the end-users. Content delivery functions are described in [ITU-T Y.1910].
+
+Content delivery functions interact with application functions, service control functions, network functions and end-user functions (e.g., functions in the home network, corporate network, etc.). Content delivery mechanisms are based on unicast and/or multicast.
+
+This Recommendation describes the content delivery functional architecture, the related functional requirements and procedures.
+
+In this Recommendation, only the NGN architecture options (IMS and non-IMS) are addressed.
+
+# Recommendation ITU-T Y.2019
+
+# Content delivery functional architecture in NGN
+
+# 1 Scope
+
+This Recommendation specifies the functional architecture of content delivery functions in NGN and the related procedures. This Recommendation builds upon the IPTV functional architecture described in [ITU-T Y.1910]. More specifically, this Recommendation provides:
+
+- an overview of content delivery functions;
+- a hierarchical architecture of content delivery functions and related reference points;
+- requirements for content delivery;
+- procedures related to content delivery functions.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.1910] | Recommendation ITU-T Y.1910 (2008), IPTV functional architecture . |
+| [ITU-T Y.2012] | Recommendation ITU-T Y.2012 (2010), Functional requirements and architecture of next generation networks . |
+| [ITU-T Y.2014] | Recommendation ITU-T Y.2014 (2010), Network attachment control functions in next generation networks . |
+| [ITU-T Y.2111] | Recommendation ITU-T Y.2111 (2008), Resource and admission control functions in next generation networks . |
+| [ITU-T Y.2701] | Recommendation ITU-T Y.2701 (2007), Security requirements for NGN release 1 . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 functional architecture** [ITU-T Y.2012]: A set of functional entities and the reference points between them used to describe the structure of an NGN. These functional entities are separated by reference points, and thus, they define the distribution of functions.
+
+NOTE – The functional entities can be used to describe a set of reference configurations. These reference configurations identify which reference points are visible at the boundaries of equipment implementations and between administrative domains.
+
+**3.1.2 linear TV** [ITU-T Y.1910]: A television service in which a continuous stream flows in real time from the service provider to the terminal device and where the user cannot control the temporal order in which contents are viewed.
+
+**3.1.3 reference point** [ITU-T Y.2012]: A conceptual point at the conjunction of two non-overlapping functional entities that can be used to identify the type of information passing between these functional entities.
+
+NOTE – A reference point may correspond to one or more physical interfaces between pieces of equipment.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 cluster:** Cluster is a grouping of content delivery processing entities with their related control entity. Such grouping allows the sharing of resources (e.g., storage capacity) based on provider's policy (e.g., taking into account parameters such as user location).
+
+**3.2.2 content aging:** The process to delete a content and related metadata from the content delivery functions.
+
+**3.2.3 content dispatching:** The process to distribute a content and related metadata within different instances of content delivery functions.
+
+**3.2.4 content ingestion:** The process of acquiring a content and related metadata by content delivery functions from content preparation functions.
+
+**3.2.5 content segment:** To improve the efficiency of content dispatching, a complete media content is needed to be divided into several serial media content. One piece of the divided media content is called a content segment.
+
+NOTE – The term content segment in this Recommendation includes non-continuous portion of content as well as continuous portion of content.
+
+**3.2.6 linear TV relay:** Entity which receives stream from a linear TV source and delivers it to the end-user using multicast or unicast.
+
+**3.2.7 pull mode:** A content delivery mode which provides delivery of content at the request of the end-user.
+
+**3.2.8 push mode:** A content delivery mode which provides delivery of content at the request of the service provider.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|----------|-----------------------------------------------------------|
+| AF | Application Functions |
+| CCF | Cluster Control Functions |
+| CDCF | Content Delivery Control Functions |
+| CDC-FE | Content Delivery Control Functional Entity |
+| CDF | Content Delivery Functions |
+| CDPF | Content Delivery Processing Functions |
+| CDP-FE | Content Delivery Processing Functional Entity |
+| CD&SF | Content Delivery & Storage Functions |
+| CD&LCF | Content Distribution & Location Control Functions |
+| CD&LC-FE | Content Distribution & Location Control Functional Entity |
+| CPRF | Content Preparation Functions |
+| FE | Functional Entity |
+
+| | |
+|---------|------------------------------------------|
+| IPTV | Internet Protocol TV |
+| IPTV AF | IPTV Application Functions |
+| LRU | Least Recently Used |
+| McCP-FB | Multicast Control Point Functional Block |
+| McR-FB | Multicast Replication Functional Block |
+| MTF | Multicast Transport Functions |
+| NACF | Network Attachment Control Functions |
+| NGN | Next Generation Networks |
+| QoS | Quality of Service |
+| RACF | Resource and Admission Control Functions |
+| RTSP | Real Time Streaming Protocol |
+| SCF | Service Control Functions |
+| SCP | Service and Content Protection |
+| UCC | User Created Content |
+| UE | User Equipment |
+| VoD | Video on Demand |
+
+# 5 Conventions
+
+**Functions:** In the context of this Recommendation, "functions" are defined as a collection of functionalities. It is represented by the following symbol:
+
+
+
+```
+
+graph TD
+ Functions[Functions]
+
+```
+
+A rounded rectangular box containing the word 'Functions'.
+
+**Functional block:** In the context of this Recommendation, a "functional block" is defined as a group of functionalities that has not been further subdivided at the level of detail described in this Recommendation. It is represented by the following symbol:
+
+
+
+```
+
+graph TD
+ FunctionalBlock[Functional Block]
+
+```
+
+A rectangular box containing the words 'Functional Block'.
+
+# 6 Content delivery overview
+
+## 6.1 Introduction
+
+Based on Figure 10-4 of [ITU-T Y.1910], Figure 6-1 underlines the functions involved in content delivery.
+
+
+
+The diagram illustrates the detailed IPTV architecture for content delivery, organized into several functional layers and blocks:
+
+- Application client functions:** Includes Service and application discovery and selection client functional block, Linear TV client functional block, On-demand client functional block, and Other client functional block(s).
+- SCP client functions:** Includes Content protection client functional block and Service protection client functional block.
+- Control client functional block:** Manages control plane operations.
+- Content delivery client functions:** Includes Error recovery client functional block, Unicast content delivery client functional block, and Multicast content delivery client functional block.
+- IPTV terminal functions:** Connects client functions to the network.
+- Home network functions:** Includes the Delivery network gateway functional block.
+- End-user functions:** The final destination for content delivery.
+- IPTV application functions:** Includes Service and application discovery and selection functional block, Linear TV application functional block, On-demand application functional block, and Other application functional block(s).
+- SCP functions:** Includes Content protection functional block and Service protection functional block.
+- Application functions:** Includes Application provisioning functional block, Application profile functional block, Content processing control functional block, Content management functional block, Metadata processing functional block, and Content pre-processing functional block.
+- Content preparation functions:** A central hub for content, metadata, and control.
+- Service control functions:** Includes IPTV service control functional block and Service user profile functional block.
+- Content delivery functions:** Includes Content distribution and location control functions (Location control, Distribution control), Content delivery and storage functions (Content delivery control, Cache/storage, Distribution, Error recovery, Content processing, Unicast delivery, Multicast delivery), and Content delivery management functional block.
+- Management functions:** Includes Application management functional block, Service control management functional block, End-user device management functional block, and Transport management functional block.
+- Content provider functions:** Includes DRM rights sources, Metadata sources, and Content sources.
+- Network functions:** Includes Authentication and IP allocation functional block, Resource control functional block, Access network functions, Edge functions, Core transport functions, Multicast transport functions (Multicast control point, Multicast replication), and Unicast transport functions.
+
+Key protocols and paths shown include: Control protocol, Unicast delivery control protocol, Error recovery control protocol, Multicast delivery control protocol, Unicast path, Multicast path, and Multicast control.
+
+Detailed IPTV architecture – Content delivery diagram showing functional blocks across various layers: Application, Management, Content provider, Service control, Content delivery, Network, and End-user.
+
+Y.2019(10)\_F6.
+
+NOTE 1 – For NGN IPTV architectures "Authentication & IP allocation functional block" is replaced by "Network attachment control functions (NACF)" [ITU-T Y.2014].
+
+NOTE 2 – For NGN IPTV architectures, "Resource control functional block" is replaced by "Resource & admission control functions (RACF)" [ITU-T Y.2111].
+
+NOTE 3 – For NGN IMS IPTV architecture, "IPTV service control functional block" is replaced by "Core IMS functions".
+
+NOTE 4 – For NGN IMS IPTV architecture, "Client control functional block" is replaced by "Session client functional block".
+
+**Figure 6-1 – Detailed IPTV architecture – Content delivery**
+
+Content delivery involves the following functions described in [ITU-T Y.1910]:
+
+- Content preparation functions (CPRF):
+ - content management functional block;
+ - metadata processing functional block;
+ - content processing control functional block;
+ - content pre-processing functional block.
+- Content delivery functions (CDF):
+ - content distribution and location control functions;
+ - content delivery and storage functions.
+
+In [ITU-T Y.1910], the functions involved in content delivery are in relationship with the management functions and the content provider functions.
+
+Note that in some cases the SCP functions are involved in the content delivery process (e.g., for content encryption).
+
+Content delivery includes the following:
+
+- content ingestion: this process loads content received from CPRF for immediate or delayed delivery;
+- content dispatching: this process distributes content within different instances of content delivery functions;
+- content delivery: this process supplies content to the end-user.
+
+## **6.2 Content ingestion**
+
+Content ingestion handles content and related metadata received from CPRF. CPRF control the preparation and aggregation of content received from the content provider functions.
+
+The ingestion process can optionally be based on:
+
+- push mechanism: once prepared, the content is sent by CPRF to the content delivery functions;
+- pull mechanism: the content is fetched from CPRF only when needed by the content delivery functions.
+
+The ingestion process can optionally include recording content. In this case, the content delivery functions perform functions that record linear content, either on demand or systematically depending on the end-user and/or service needs. This recording is for immediate or delayed delivery.
+
+## **6.3 Content dispatching**
+
+After ingestion, content can optionally be duplicated through the content delivery functions depending on a predefined policy.
+
+For example, popular content can optionally be duplicated on all content delivery functions, local content can optionally reside only in certain targeted areas and rare contents are less duplicated than the latter two.
+
+The policy for duplication can optionally be defined on a static basis or dynamically updated, e.g., based on usage statistics.
+
+## **6.4 Content delivery**
+
+Content delivery supplies content to the end-user under the control of the application functions. The related procedures are detailed in Appendix I of [ITU-T Y.1910].
+
+# 7 Content delivery functions
+
+Content delivery capabilities allow IPTV end-users to select, watch and/or listen to video or audio content. Content delivery capabilities either stream content through end-user functions, allowing viewing in real time, or download it to end-user functions with storage ability (e.g., personal computer, digital video recorder or portable media player) for viewing at any time.
+
+By using the content delivery capabilities, a service provider delivers linear TV content to the IPTV terminal device with the optional capability to record, rewind, and pause, over the network. The content delivery capabilities allow the delivery of IPTV content to IPTV end-users by responding dynamically to IPTV user's requests.
+
+The content delivery capabilities can optionally support two delivery modes towards IPTV end-users: multicast delivery and unicast delivery.
+
+In the content delivery architecture, either download of the content from a single storage instance or download of the content in segments from multiple storage instances is supported.
+
+## 7.1 Content delivery functions in the IPTV architecture
+
+Figure 7-1 shows the content delivery functions in the IPTV architecture and the corresponding reference points (refer to [ITU-T Y.1910] for further details).
+
+
+
+The diagram illustrates the content delivery functions in the IPTV architecture, organized into two main functional blocks:
+
+- Content distribution and location control functions:** This block contains two sub-functional blocks:
+ - Location control functional block
+ - Distribution control functional block
+- Content delivery and storage functions:** This block contains seven sub-functional blocks:
+ - Content delivery control functional block
+ - Cache/storage functional block
+ - Distribution functional block
+ - Error recovery functional block
+ - Content processing functional block
+ - Unicast delivery functional block
+ - Multicast delivery functional block
+
+Reference points are indicated by lines connecting the blocks to labels:
+
+- Top: A2, C2, C1
+- Left: S1, D1, S5, E6, E4
+- Bottom: Uc, Mc, Md
+
+v.2019(10)\_F7.1
+
+Figure 7-1: Content delivery functions in the IPTV architecture. The diagram shows two main functional blocks: 'Content distribution and location control functions' and 'Content delivery and storage functions'. The top block contains 'Location control functional block' and 'Distribution control functional block'. The bottom block contains 'Content delivery control functional block', 'Cache/storage functional block', 'Distribution functional block', 'Error recovery functional block', 'Content processing functional block', 'Unicast delivery functional block', and 'Multicast delivery functional block'. Reference points A2, C2, and C1 are at the top; S1, D1, S5, E6, and E4 are on the left; and Uc, Mc, and Md are at the bottom. A small version number 'v.2019(10)\_F7.1' is at the bottom right.
+
+**Figure 7-1 – Content delivery functions in [ITU-T Y.1910]**
+
+In [ITU-T Y.1910], the content delivery functions consist of two groups of functions:
+
+- content distribution & location control functions (CD&LCF);
+- content delivery & storage functions (CD&SF).
+
+In the context of this Recommendation, the CD&SF, as defined in [ITU-T Y.1910], is split into two parts as shown in Figure 7-2:
+
+- content delivery control functions (CDCF) including the following functional block:
+ - content delivery control;
+- content delivery processing functions (CDPF) including the following functional blocks:
+ - cache/storage;
+ - distribution;
+ - content processing;
+ - unicast delivery;
+ - error recovery;
+ - multicast delivery.
+
+NOTE – Error recovery and multicast delivery functional blocks are optional.
+
+A new reference point, i.e., the D2 reference point, is added between CDCF and CDPF.
+
+Such functional split allows the support of the deployment scenarios described in this Recommendation.
+
+The functional architecture shown in Figure 7-2 is compatible with the NGN functional architecture, as described in clause 9.3.4 of [ITU-T Y.2012]. More specifically:
+
+- The CD&LCF correspond to the CD&LC-FE as per clause 9.3.4.1 of [ITU-T Y.2012];
+- The CDCF correspond to the CDC-FE as per clause 9.3.4.2 of [ITU-T Y.2012];
+- The CDPF correspond to the CDP-FE as per clause 9.3.4.3 of [ITU-T Y.2012].
+
+
+
+Figure 7-2: Content delivery functional architecture diagram. The diagram shows three stacked functional blocks: 'Content distribution and location control functions' (top), 'Content delivery control functions' (middle), and 'Content delivery processing functions' (bottom). The top block contains 'Location control functional block' and 'Distribution control functional block', with reference points A2 and C1. The middle block contains 'Content delivery control functional block', with reference points S1, S5, E6, and D1. The bottom block contains 'Cache/storage functional block', 'Distribution functional block', 'Error recovery functional block' (dashed), 'Content processing functional block', 'Unicast delivery functional block', and 'Multicast delivery functional block' (dashed), with reference points D2, E4, and C2. At the bottom, there are labels Uc, Mc, and Md. A version number 'Y.2019(10)\_F7.2' is at the bottom right.
+
+**Figure 7-2 – Content delivery functional architecture**
+
+## 7.2 Hierarchical content delivery architecture
+
+The content delivery functional architecture shown in Figure 7-2 is flexible and can be deployed in different ways depending on the delivery constraints.
+
+This clause describes a hierarchical model based on the use of the following three types of functions:
+
+- content distribution & location control functions (CD&LCF);
+- cluster control functions (CCF) which groups content distribution & location control functions (CD&LCF) and content delivery control functions (CDCF);
+- content delivery processing functions (CDPF).
+
+A given instance of the CD&LCF manages one or multiple instances of CCF.
+
+A given instance of CCF manages one or multiples instances of CDPF.
+
+This hierarchical architecture can optionally involve more than two levels of control (CD&LCF and CCF) depending on scalability constraints.
+
+Figure 7-3 shows the hierarchical content delivery architecture.
+
+
+
+The diagram illustrates a hierarchical content delivery architecture with three main functional blocks stacked vertically, each containing sub-functional blocks and connected by reference points.
+
+- Top Block: Content distribution and location control functions**
+ - Sub-blocks: Location control functional block, Distribution control functional block.
+ - Reference points: A2 (input), C1 (input), D3 (output), S1 (input).
+- Middle Block: Cluster control functions**
+ - Sub-blocks: Location control functional block, Distribution control functional block, Content delivery control functional block.
+ - Reference points: D1' (input), D4 (output), S1' (input), E6 (input).
+- Bottom Block: Content delivery processing functions**
+ - Sub-blocks: Cache/storage functional block, Distribution functional block, Error recovery functional block, Content processing functional block, Unicast delivery functional block, Multicast delivery functional block.
+ - Reference points: D2 (input), D5 (output), E4 (input), Uc (output), Mc (output), Md (output).
+
+Reference points D3, D4, and D5 are shown as curved arrows indicating feedback or control loops. The reference point D1' is a straight line. The reference point D2 is a straight line. The reference points A2, C1, S1, S1', E6, E4, Uc, Mc, and Md are straight lines.
+
+Y.2019(10)\_F7.3
+
+Figure 7-3: Hierarchical content delivery architecture diagram showing three stacked functional blocks: Content distribution and location control functions, Cluster control functions, and Content delivery processing functions, with various reference points and sub-blocks.
+
+**Figure 7-3 – Hierarchical content delivery architecture**
+
+Figure 7-3 shows the reference points between different instances of the content delivery functions.
+
+The D3 reference point is between different CD&LCF instances, allowing the selection on the optimal CD&LCF instance.
+
+The D4 reference point is between different CCF instances, allowing content distribution control and content location control signalling transfer.
+
+The D5 reference point is between different instances of CDPF allowing content distribution.
+
+The D3, D4 and D5 reference points are optional.
+
+The hierarchical architecture supports two sub-models:
+
+- hierarchical architecture with functions of the same level that are not connected to each other;
+- hierarchical architecture with functions of the same level that can optionally be connected to each other. In this case, the D3, D4, D5 reference points can optionally be used.
+
+### **7.2.1 Content distribution & location control functions (CD&LCF)**
+
+The CD&LCF include two functional blocks: the location control functional block and the distribution control functional block which are defined in [ITU-T Y.1910].
+
+The CD&LCF are used for overall control of the content delivery process. The CD&LCF are used as the main entry for service requests from IPTV application functions through the A2 reference point or from service control functions through the S1 reference point. The CD&LCF control one or multiple instances of cluster control functions (CCF).
+
+### **7.2.2 Cluster control functions (CCF)**
+
+The CCF include three functional blocks: location control, distribution control and content delivery control functional blocks which are defined in [ITU-T Y.1910].
+
+The CCF are used as the entry for service request from IPTV application functions through the S1' reference point. The CCF are also used for media content control (e.g., for RTSP control) through the E6 reference point. The CCF control one or multiple instances of CDPF.
+
+### **7.2.3 Content delivery processing functions (CDPF)**
+
+The CDPF include six functional blocks: cache/storage, distribution, error recovery, content processing, unicast delivery and multicast delivery defined in [ITU-T Y.1910].
+
+Error recovery and multicast delivery functional blocks are optional.
+
+The CDPF are used for content delivery (unicast or multicast) and content distribution (content ingestion, content dispatching and content aging) under the control of CCF.
+
+# **8 Content delivery requirements**
+
+Note that this Recommendation follows also requirements provided in [ITU-T Y.1910], and these requirements are additional requirements to [ITU-T Y.1910].
+
+## **8.1 Mandatory requirements**
+
+The requirements provided in this clause are mandatory.
+
+- R1: The content delivery functions are required to support mechanisms to select the content delivery processing functions (CDPF) instance for a specific end-user or set of end-users based on provider policies (e.g., end-user location, content availability, load of the content delivery processing functions, etc.).
+- R2: The content delivery functions are required to support delivery of the content through streaming and download.
+- R3: The content delivery functions are required to support content ingesting, dispatching, aging and delivery.
+
+- R4: The content delivery functions are required to provide mechanisms to collect and maintain the data related to the content distribution in order to allocate end-user's requests to the appropriate content delivery processing functions (CDPF) instance.
+- R5: The content delivery functions are required to provide mechanisms to collect data related to the content popularity (e.g., the number of end-user's requests, etc.).
+- R6: The content delivery functions are required to provide reporting abilities between the different functions (e.g., availability of content delivery processing functions instances, unexpected signalling from the end-user functions, etc.).
+- R7: In case of hierarchical architecture, the content delivery functions are required to support dispatching of content between different instances of content delivery processing functions.
+
+## **8.2 Optional requirements**
+
+The requirements provided in this clause are optional.
+
+- R8: The content delivery functions can optionally provide different priority levels for content and/or services.
+- R9: The content delivery functions are recommended to support content segmentation mechanism (i.e., divide the content in smaller pieces) for efficient content dispatching.
+- R10: The content delivery functions can optionally support distribution and delivery of user created content (UCC).
+- R11: The content delivery functions can optionally support multicast content delivery mechanisms.
+- R12: The content delivery functions can optionally support FEC or retransmission mechanisms.
+- R13: The content delivery functions can optionally support seamless content serving transfer from one content delivery function instance to another content delivery function instance when the end-user moves from one geographical area to another area.
+- R14: The content delivery functions can optionally provide a mechanism to support advertisement insertion for unicast streaming.
+
+# **9 Reference points**
+
+This Recommendation uses the existing A2, C1, C2, S1, E4, E6, Uc, Mc and Md reference points defined in [ITU-T Y.1910] and defines new reference points as follows.
+
+## **9.1 Reference point D1' between CD&LCF and CCF**
+
+The D1' reference point between CD&LCF and CCF allows CD&LCF to get status information from CCF such as load status on each instance of content delivery functions. It can optionally be used to locate the appropriate CCF instance for controlling the delivery of the content to the end-user. The D1' reference point serves for controlling content ingestion and optionally for performing content dispatching or content aging to and within the content delivery functions.
+
+## **9.2 Reference point D2 between CCF and CDPF**
+
+The D2 reference point between CCF and CDPF allows CD&LCF to get status information from CDPF instances such as load status on each instance that the CCF controls. The D2 reference point is used to locate the appropriate CDPF instance for controlling the delivery of the content to the end-user. The D2 reference point serves for performing content dispatching and content aging within the content delivery functions.
+
+## **9.3 Reference point D3 between different CD&LCF**
+
+The D3 reference point between different CD&LCF instances allows caching content distribution and content delivery control-related signalling between CD&LCF to locate the appropriate CD&LCF instance.
+
+## **9.4 Reference point D4 between different CCF**
+
+The D4 reference point between different CCF instances allows CCF to transfer the session establishment, modification, or termination request to other CCF instances. Additionally, the D4 reference point is also used for the transfer of content dispatching requests and content aging requests.
+
+## **9.5 Reference point D5 between different CDPF**
+
+The D5 reference point between different CDPF instances allows the content to be distributed among different CDPF under the control of CCF.
+
+## **9.6 Reference point S1' between SCF and CCF**
+
+The S1' reference point between SCF and CCF is identical to the S1 reference point as defined in [ITU-T Y.1910]. Unicast content control signalling request (e.g., VoD content request) is directly coming from SCF to the specified CCF.
+
+# **10 Hierarchical model deployment principles**
+
+## **10.1 General principles**
+
+This clause describes general principles that can optionally be applied to hierarchical architecture regarding content delivery functions.
+
+The hierarchical architecture described in this clause allows the optimization of the network use through a distribution of the media servers in the network, and the optimization of the storage resources of the content on the media servers, based on provider criteria. For example, if the criterion is the popularity of the content, popular content is distributed on media servers at the edge of the network (as close as possible to the customer), while less popular content is distributed on a reduced number of media servers.
+
+Figure 10-1 describes an example of hierarchical architecture deployment involving different instances of functions related to content delivery.
+
+
+
+Figure 10-1: Example of hierarchical architecture deployment. The diagram shows a hierarchical structure starting with 'IPTV applications functions/service control functions' at the top. Below it is 'Content distribution and location control functions CD & LCF'. This connects to multiple 'Cluster control functions CCF' (CCF 1, CCF 2, ..., CCF m) via reference points D1'. Each CCF connects to multiple 'Content delivery processing functions CDPF' (CDPF 1-1, CDPF 1-2, ..., CDPF 1-n for CCF 1; CDPF 2-1, CDPF 2-2, ..., CDPF 2-p for CCF 2) via reference points D2. Interconnections are shown: D3 between CD & LCF and CCFs; D4 between CCFs; and D5 between CDPFs within a cluster. Reference points D1', D2, D3, D4, and D5 are indicated by solid and dashed lines.
+
+**Figure 10-1 – Example of hierarchical architecture deployment**
+
+The deployment of CDPF can optionally be based on the following criteria:
+
+- one CDPF is managed by only one CCF, so one CDPF belongs to only one cluster;
+- content available to customers is not necessarily distributed uniformly among the CDPF;
+- a content can optionally be available in some CDPF within a given cluster and absent in other CDPF within the same cluster.
+
+Depending on the context, functions of the same level (i.e., different instances of CD&LCF, CCF or CDPF) can optionally be interconnected (using the D3, D4 or D5 reference points).
+
+## 10.2 Selection
+
+### 10.2.1 CD&LCF selection
+
+If there are more than one CD&LCF, IPTV AF select one CD&LCF for UE, based on some criteria, for example:
+
+- geographical location of the UE: CD&LCF is selected based on the UE location, such as the parameter of the IP address in the service request;
+- service capability: The service capability includes the CD&LCF own service capability and the capability of the CCF under it.
+
+### 10.2.2 CCF selection
+
+The CCF instance is selected by CD&LCF based on some criteria, for example:
+
+- geographical location of the UE: CCF is selected based on the UE location, such as the parameter of the IP address in the service request;
+- content availability: CCF is selected according to the content availability of the UE's request;
+
+- service capability: The service capability includes the CCF's service capability and the streaming capability of the CDF organized by the CCF.
+
+### 10.2.3 CDPF selection
+
+The CDPF instance is selected by CCF based on some criteria, for example:
+
+- geographical location of the UE: The CDPF is selected according to geographical location of the UE, and selects a nearest CDPF to service for UE;
+- content availability: The CDPF is selected according to the content availability of the UE's request.
+
+# 11 Content delivery procedures
+
+The following clauses describe basic procedures for content delivery.
+
+## 11.1 Generic content delivery procedures
+
+Generic procedures related to content delivery functions are described in [ITU-T Y.1910].
+
+## 11.2 Hierarchical content delivery procedures
+
+This clause provides procedures related to the hierarchical content delivery architecture described in clause 7.2 in line with the requirements identified in clause 8.
+
+### 11.2.1 Content ingestion procedure
+
+This procedure covers the mandatory requirement R3 (see clause 8.1).
+
+Figure 11-1 describes the content ingestion procedure, i.e., how content is ingested from CPRF to different CDPF.
+
+
+
+```
+
+sequenceDiagram
+ participant CPRF
+ participant CD_LCF as CD & LCF
+ participant CCF
+ participant CDPF
+
+ CPRF->>CD_LCF: 1. Content ingestion request
+ activate CD_LCF
+ CD_LCF->>CCF: 2. Select CCF to ingest content
+ deactivate CD_LCF
+ activate CCF
+ CCF->>CDPFCDPF: 3. Content ingestion request
+ activate CDPF
+ CDPF->>CCF: 4. Select CDPF to ingest content
+ deactivate CDPF
+ activate CCF
+ CCF->>CDPFCDPF: 5. Content ingestion request
+ activate CDPF
+ CDPF->>CCF: 6. Content ingestion response
+ deactivate CDPF
+ CCF->>CD_LCF: 7. Content ingestion response
+ deactivate CCF
+ activate CD_LCF
+ CD_LCF->>CPRF: 8. Content ingestion response
+ deactivate CD_LCF
+ CPRF-->>CDPFCDPF: 9. Content ingestion
+
+```
+
+The diagram shows a sequence of steps for content ingestion. It involves four entities: CPRF, CD & LCF, CCF, and CDPF. The process starts with CPRF sending a 'Content ingestion request' to CD & LCF. CD & LCF then selects a CCF and sends a 'Content ingestion request' to it. The CCF then selects a CDPF and sends a 'Content ingestion request' to it. The CDPF sends a 'Content ingestion response' back to the CCF, which then sends a 'Content ingestion response' back to CD & LCF. Finally, CD & LCF sends a 'Content ingestion response' back to CPRF. A final step, 'Content ingestion', is shown as a wide bar at the bottom, indicating the overall process.
+
+Sequence diagram illustrating the content ingestion procedure between CPRF, CD & LCF, CCF, and CDPF.
+
+Y.2019(10)\_F11.1
+
+**Figure 11-1 – Content ingestion procedure**
+
+Pre-conditions:
+
+It is assumed that:
+
+- content metadata and content protection rights information have been delivered from the content provider functions to content preparation functions (CPRF);
+- content preparation procedures are completed.
+
+NOTE 1 – Content preparation procedures include content aggregation, content management, metadata processing, content processing and content encryption as defined in [ITU-T Y.1910].
+
+The procedure shown in Figure 11-1 includes the following steps:
+
+- 1) the CPRF identify the CD&LCF and send a content ingestion request to the selected CD&LCF;
+- 2) the CD&LCF enforce specific ingestion policy and select one or multiple clusters to receive the content;
+- 3) the CD&LCF send a content ingestion request to the CCF of the selected clusters;
+- 4) the CCF select one or multiple CDPF according to a specific ingestion policy to receive the content;
+- 5) the CCF send a content ingestion request to the selected CDPF;
+- 6) the selected CDPF provide an acknowledgement to the CCF that the content can be ingested;
+- 7) the selected CCF provide an acknowledgement to the CD&LCF that the content can be ingested;
+- 8) the CD&LCF provide an acknowledgement to the CPRF that the content can be ingested;
+- 9) the CPRF transfer the content to the selected CDPF.
+ - a) the content transport method can optionally be pull mode, i.e., the CDPF initiate the download of the content from the CPRF;
+ - b) the content transport method can optionally be push mode, i.e., the CPRF initiate the delivery of the content to CDPF.
+
+NOTE 2 – In case the content needs to be segmented, the corresponding procedure for content dispatching is described in clause 11.2.2.
+
+### **11.2.2 Content dispatching procedure**
+
+#### **11.2.2.1 Content dispatching procedure with unicast**
+
+This procedure covers mandatory requirement R7 (see clause 8.1).
+
+Figure 11-2 describes the content dispatching procedure, i.e., how content is distributed among different CDPF.
+
+
+
+```
+
+sequenceDiagram
+ participant C1_CCF as CCF Cluster 1
+ participant C1_CDPF as CDPF Cluster 1
+ participant C2_CCF as CCF Cluster 2
+ participant C2_CDPF as CDPF Cluster 2
+
+ Note over C1_CCF: 1) Dispatching judge
+ C1_CCF->>C2_CCF: 2) Segment query request
+ Note over C2_CCF: 3) Check if the segment exists
+ C2_CCF-->>C1_CCF: 4) Segment query response
+ C1_CCF->>C1_CDPF: 5) Segment receive
+ C1_CDPF-->>C1_CCF: 6) Ready
+ C1_CCF->>C2_CCF: 7) Segment dispatching request
+ Note over C2_CCF: 8) Query the location of the segment
+ C2_CCF->>C2_CDPF: 9) Segment request
+ C2_CDPF-->>C2_CCF: 10) Response
+ C2_CCF-->>C1_CCF: 11) Segment dispatching response
+ C2_CDPF->>C1_CDPF: 12) Content download
+ Note over C1_CDPF: 13) End of download
+
+```
+
+Y.2019(10)\_F11.2
+
+Sequence diagram illustrating the Content dispatching procedure between Cluster 1 and Cluster 2. Cluster 1 contains CCF and CDPF components. Cluster 2 contains CCF and CDPF components. The procedure consists of 13 steps: 1) Dispatching judge (local to CCF in Cluster 1), 2) Segment query request (CCF Cluster 1 to CCF Cluster 2), 3) Check if the segment exists (local to CCF Cluster 2), 4) Segment query response (CCF Cluster 2 to CCF Cluster 1), 5) Segment receive (CCF Cluster 1 to CDPF Cluster 1), 6) Ready (CDPF Cluster 1 to CCF Cluster 1), 7) Segment dispatching request (CCF Cluster 1 to CCF Cluster 2), 8) Query the location of the segment (local to CCF Cluster 2), 9) Segment request (CCF Cluster 2 to CDPF Cluster 2), 10) Response (CDPF Cluster 2 to CCF Cluster 2), 11) Segment dispatching response (CCF Cluster 2 to CCF Cluster 1), 12) Content download (CDPF Cluster 2 to CDPF Cluster 1), and 13) End of download (local to CDPF Cluster 1).
+
+**Figure 11-2 – Content dispatching procedure**
+
+The procedure shown in Figure 11-2 includes the following steps:
+
+- 1) when the CCF of cluster 1 receive a content request from the end-user functions, the CCF discover that some content segments are not available in cluster 1;
+- 2) the CCF of cluster 1 send a segment request to the CCF of other clusters to query if they can supply the content segment;
+- 3) the CCF of cluster 2 check if the content segment is available in cluster 2. The assumption is that the content segment is available in cluster 2;
+- 4) the CCF of cluster 2 send a segment query response to the CCF of cluster 1 indicating that the content segment is available in cluster 2;
+- 5) the CCF of cluster 1 send a segment receiving notification to the CDPF of cluster 1;
+- 6) the CDPF of cluster 1 confirm to the CCF of cluster 1 that it can receive the content segment;
+- 7) the CCF of cluster 1 send a segment dispatching request to the CCF of cluster 2;
+- 8) the CCF of cluster 2 query the location of the content segment in the CDPF of cluster 2;
+- 9) the CCF of cluster 2 send a segment request to the selected CDPF of cluster 2 to distribute the requested content segment;
+- 10) the CDPF of cluster 2 confirm the received segment request to the CCF of cluster 2;
+- 11) the CCF of cluster 2 send a segment dispatching response to the CCF of cluster 1 to confirm the segment dispatching;
+- 12) the CDPF of cluster 2 download the content segment to the CDPF of cluster 1;
+
+- 13) when the content download is achieved, the CDPF of cluster 1 notify the segment dispatching result to the CCF of cluster 1.
+
+#### 11.2.2.2 Content dispatching procedure with multicast
+
+This procedure covers optional requirement R11 (see clause 8.2).
+
+Figure 11-3 describes the content dispatching procedure with multicast mode.
+
+
+
+```
+
+sequenceDiagram
+ participant CD_LCF as CD & LCF
+ participant Cluster1 as Cluster 1
+ participant Cluster2 as Cluster 2
+ participant CCF1 as CCF
+ participant CDPF1 as CDPF
+ participant MTF1 as MTF
+ participant CCF2 as CCF
+ participant CDPF2 as CDPF
+
+ CD_LCF->>CCF1: 1) Multicast request
+ CCF1->>CDPF1: 2) Request
+ CDPF1->>MTF1: 3) Request
+ MTF1->>CDPF1: 4) Ready for receiving
+ CDPF1->>CCF1: 5) Ready
+ CCF1->>CD_LCF: 6) Multicast transfer ready
+ CCF1->>CD_LCF: 7) Query cluster information
+ Note over CD_LCF: 8) Allocate cluster for multicast stream
+ CD_LCF->>CCF1: 9) Response
+ CCF1->>CDPF2: 10) Session request
+ Note over CDPF2: 11) Select CDPF and session setup
+ CDPF2->>CCF1: 12) Session response
+ CCF1->>CDPF1: 13) Request for multicast
+ CDPF1->>MTF1: 14) Content stream
+ Note over MTF1: 15) Stream replications
+ MTF1->>CDPF2: 16) Content stream
+
+```
+
+Sequence diagram illustrating the content dispatching procedure with multicast mode. The diagram shows interactions between CD & LCF, Cluster 1 (CCF, CDPF, MTF), and Cluster 2 (CCF, CDPF).
+
+Y.2019(10)\_F11.3
+
+**Figure 11-3 – Content dispatching procedure with multicast**
+
+NOTE 1 – It is assumed that the multicast transport functions (MTF) are located in cluster 1. MTF are functions in the NGN transport stratum which can optionally be located inside or outside of cluster 1 depending on the implementation. MTF include a multicast control point functional block (McCP-FB) and a multicast replication functional block (McR-FB) as defined in [ITU-T Y.1910].
+
+NOTE 2 – CD&LCF maintain information about content availability in clusters.
+
+NOTE 3 – It is assumed that the content is available in cluster 1 and will be delivered to cluster 2 by means of multicast mechanisms.
+
+The procedure shown in Figure 11-3 includes the following steps:
+
+- 1) the CD&LCF trigger a multicast request to the CCF of cluster 1;
+- 2) the CCF forward the multicast request to the appropriate CDPF;
+- 3) the selected CDPF send a multicast request to the MTF;
+- 4) the MTF send an acknowledgement to the CDPF;
+
+- 5) the CDPF forward the acknowledgement;
+- 6) the CCF forward the acknowledgement and inform that multicast transfer is ready;
+- 7) the CCF send a cluster information query to the CD&LCF;
+- 8) the CD&LCF select a cluster to be used for content delivery;
+- 9) the corresponding cluster information is returned to the CCF;
+- 10) the CCF of cluster 1 send a session request to the selected CCF of cluster 2;
+- 11) the CCF of cluster 2 send a session request to the appropriate CDPF of cluster 2 and set up the content delivery session;
+- 12) the content delivery session identification is returned, through the service session setup response, to the CCF of cluster 1;
+- 13) the CCF of cluster 1 send a request for multicast delivery to the CDPF;
+- 14) the CDPF of cluster 1 stream the media to the MTF;
+- 15) the MTF replicate the received media;
+- 16) the MTF stream the replicated media to the CDPF of cluster 2.
+
+### 11.2.3 Content aging procedure
+
+The procedures in this clause cover mandatory requirement R3 (see clause 8.1).
+
+For content aging, the following methods can optionally be used:
+
+- Cluster controlled content aging
+For this content aging method, the CD&LCF is not required to know which content is stored in the clusters. The CCF within the cluster manages its own content. The cluster only needs to know the topology of the network. This method is mainly used for the case where content is required to be segmented, given that it may be difficult for the CD&LCF to manage several content segments distributed throughout the network. The detailed procedure is described in clause 11.2.3.1.
+- CD&LCF and cluster controlled content aging
+For this content aging method, the CD&LCF is required to know which content is stored in the clusters of the network. This method is mainly used for the case where content is not required to be segmented. Since the CCF initiate the content aging process, it is called pull mode-based content aging. The detailed procedure is described in clause 11.2.3.2.
+- CD&LCF controlled content aging
+For this content aging method, the CD&LCF need to know which content is stored in the clusters of the network. This method is used for the case where content is not required to be segmented. Since the CD&LCF initiate the content aging process, it is called push mode-based content aging. The detailed procedure is described in clause 11.2.3.3.
+For content aging policy, some algorithms, such as least recently used (LRU) algorithm can optionally be used to decide which content (segment or complete content) will be aged.
+
+#### 11.2.3.1 Cluster controlled content aging procedure
+
+Figure 11-4 describes the cluster controlled content aging procedure.
+
+
+
+```
+
+sequenceDiagram
+ participant CCF
+ participant CDPF
+ Note over CCF, CDPF: Cluster 1
+ Note left of CCF: 1) Timing
+ CCF->>CDPF: 2) Content aging request
+ Note right of CDPF: 3) Content aging
+ CDPF-->>CCF: 4) Content aging response
+
+```
+
+Y.2019(10)\_F11.4
+
+Sequence diagram for Cluster controlled content aging procedure (Figure 11-4).
+
+**Figure 11-4 – Cluster controlled content aging procedure**
+
+The procedure shown in Figure 11-4 contains the following steps:
+
+- 1) the CCF is assumed to perform a content aging task periodically. A timer is used to control the execution of the content aging task;
+- 2) each time the timer expires, the CCF check whether the content is aged and in case the content is aged, the CCF send a content aging request to the CDPF to indicate to the CDPF which content is required to be aged;
+- 3) the CDPF execute content aging (i.e., delete the content) according to the indication of the CCF;
+- 4) when the content aging is successfully achieved, the CDPF confirm the content aging result to the CCF.
+
+#### 11.2.3.2 CD&LCF and cluster controlled content aging procedure
+
+Figure 11-5 describes the CD&LCF and cluster controlled content aging procedure.
+
+
+
+```
+
+sequenceDiagram
+ participant CD_LCF as CD & LCF
+ participant CCF
+ participant CDPF
+ Note over CCF, CDPF: Cluster 1
+ Note left of CCF: 1) Timing
+ CCF->>CD_LCF: 2) Content aging request
+ CD_LCF->>CCF: 3) Content aging confirmation
+ CCF->>CDPF: 4) Content aging request
+ Note right of CDPF: 5) Content aging
+ CDPF-->>CCF: 6) Content aging response
+ CCF-->>CD_LCF: 7) Content aging response
+
+```
+
+Y.2019(10)\_F11.5
+
+Sequence diagram for CD&LCF and cluster controlled content aging procedure (Figure 11-5).
+
+**Figure 11-5 – CD&LCF and cluster controlled content aging procedure**
+
+The procedure shown in Figure 11-5 contains the following steps:
+
+- 1) the CCF is assumed to perform a content aging task periodically. A timer is used to control the execution of the content aging task;
+- 2) each time the timer expires, the CCF send a content aging request to the CD&LCF to indicate which content is required to be aged;
+- 3) the CD&LCF judge if the content can be aged. If the content is aged, the CD&LCF send a content aging confirmation to the CCF to indicate that the content can be aged;
+- 4) the CCF send a content aging request to the CDPF to indicate to the CDPF which content needs to be aged;
+- 5) the CDPF execute content aging (i.e., delete the content) according to the indication of the CCF;
+- 6) when the content aging is successfully achieved, the CDPF confirm the content aging result to the CCF;
+- 7) the CCF send a content aging confirmation notification to the CD&LCF.
+
+#### 11.2.3.3 CD&LCF controlled content aging procedure
+
+Figure 11-6 describes the CD&LCF controlled content aging procedure.
+
+
+
+```
+
+sequenceDiagram
+ participant CD_LCF as CD & LCF
+ box Cluster 1
+ participant CCF
+ participant CDPF
+ end
+
+ Note left of CD_LCF: 1) Timing
+ CD_LCF->>CCF: 2) Content aging request
+ CCF->>CDPF: 3) Content aging request
+ Note right of CDPF: 4) Content aging
+ CDPF->>CCF: 5) Content aging response
+ CCF->>CD_LCF: 6) Content aging response
+
+```
+
+Y.2019(10)\_F11.6
+
+Sequence diagram illustrating the CD&LCF controlled content aging procedure. The diagram shows three main components: CD & LCF, Cluster 1 (containing CCF and CDPF), and a timer. The steps are: 1) Timing (timer icon), 2) Content aging request from CD & LCF to CCF, 3) Content aging request from CCF to CDPF, 4) Content aging (action box on CDPF), 5) Content aging response from CDPF to CCF, and 6) Content aging response from CCF to CD & LCF.
+
+**Figure 11-6 – CD&LCF controlled content aging procedure**
+
+The procedure shown in Figure 11-6 contains the following steps:
+
+- 1) the CD&LCF is assumed to perform a content aging task periodically. A timer is used to control the execution of the content aging task;
+- 2) each time the timer expires, the CD&LCF check whether the content is aged and in case the content has aged, the CD&LCF send a content aging request to the CCF to indicate which content is required to be aged;
+- 3) the CCF send a content aging request to the CDPF to indicate which content is required to be aged;
+- 4) the CDPF execute content aging (i.e., delete the content) according to the indication of the CCF;
+- 5) when the content aging is successfully achieved, the CDPF confirm the content aging result to the CCF;
+
+6) the CCF send a content aging confirmation notification to the CD&LCF.
+
+### 11.2.4 Content delivery procedure
+
+#### 11.2.4.1 Procedure of content delivery with unicast
+
+The procedures in this clause cover mandatory requirement R2 (see clause 8.1).
+
+SCF/IPTV AF requests the content from CCF in a specific cluster. The choice of this cluster is based on some criteria (see clause 10.2.2, for example, geographical criteria, QoS criteria, etc.). After selection of a cluster, three cases could appear:
+
+- Case 1: The selected cluster (referred to as cluster 1) has serving capability.
+- Case 2: Cluster 1 has no serving capability, so cluster 1 relays the request to CD&LCF, which selects a new candidate cluster (referred to as cluster 2) which has serving capability.
+ - Case 2-1: Cluster 2 streams directly the content to the end-user functions.
+ - Case 2-2: Cluster 1 fetches the content from cluster 2, and delivers the content to the end-user functions.
+
+Procedures described in this clause are related to the upper cases.
+
+##### 11.2.4.1.1 Case 1: Content available in cluster 1
+
+Figure 11-7 describes the procedure where cluster 1 can serve the end-user functions.
+
+
+
+```
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant Cluster1 as Cluster 1
+ participant CCF as CCF
+ participant CDPF as CDPF
+
+ Note over End-user, SCF: 1) Session request (including resource reservation, e.g., via RACF)
+ SCF->>CCF: 2) Session request
+ Note over CCF: 3) Check if it has the serving capability
+ Note over CCF: 4) Session setup
+ CCF->>SCF: 5) Session response
+ Note over End-user, SCF: 6) Session response (including resource submit, e.g., via RACF)
+ SCF->>CCF: 7) Stream control
+ CCF->>CDPF: 8) Stream control
+ CCF->>End-user: 9) Content stream
+```
+
+The diagram illustrates the sequence of operations for Case 1. It involves three main entities: End-user functions, SCF/IPTV AF, and Cluster 1 (which contains CCF and CDPF). The process begins with a session request from the End-user functions to the SCF/IPTV AF. The SCF/IPTV AF then sends a session request to the CCF in Cluster 1. The CCF checks its serving capability and performs session setup. A session response is sent from the CCF back to the SCF/IPTV AF. The SCF/IPTV AF then sends a session response (including resource submit) back to the End-user functions. Next, the SCF/IPTV AF sends stream control to the CCF, which then sends stream control to the CDPF. Finally, the CCF sends the content stream to the End-user functions.
+
+Sequence diagram for Case 1: Content available in cluster 1. The diagram shows interactions between End-user functions, SCF/IPTV AF, and Cluster 1 (containing CCF and CDPF).
+
+Y.2019(10)\_F11.7
+
+**Figure 11-7 – Case 1, Content available in cluster 1**
+
+The procedure shown in Figure 11-7 contains the following steps:
+
+- 1) the procedure is triggered by an action from the end-user. The end-user requests content from the IPTV AF which results in a unicast session request from end-user functions to the SCF;
+- 2) the SCF forward the service session request to the CCF of cluster 1;
+- 3) the CCF of cluster 1 check if they have the serving capability (e.g., if the requested content is available in the cluster, if the load in cluster 1 is below a given threshold, etc.);
+- 4) if cluster 1 can supply the content, the CCF send a session request to the appropriate CDPF and establish a content delivery session;
+- 5) the content delivery session identification is returned through the service session setup response to the SCF;
+- 6) the SCF forward the service session response to the end-user functions. Reserved resources are allocated in this step (e.g., via RACF as specified in [ITU-T Y.2111]);
+- 7) stream control requests generated by the end-user functions are sent to the CCF of cluster 1;
+- 8) the CCF of cluster 1 cache the stream control requests to the appropriate CDPF;
+- 9) the CDPF stream the media directly to the end-user functions.
+
+##### 11.2.4.1.2 Case 2-1: Content not available in cluster 1 and direct streaming from cluster 2
+
+Figure 11-8 describes the procedure where cluster 1 cannot serve the end-user, whereas cluster 2 is able to serve the end-user.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant Cluster1 as Cluster 1
+(CCF, CDPF)
+ participant CD_LCF as CD & LCF
+ participant Cluster2 as Cluster 2
+(CCF, CDPF)
+
+ Note over End-user, SCF: 1) Session request
+(including resource reservation, e.g., via RACF)
+ SCF->>Cluster1: 2) Session request
+ Note over Cluster1: 3) Check if it has the serving capability
+ Cluster1->>CD_LCF: 4) Query the cluster serving instance
+ Note over CD_LCF: 5) Allocate the new cluster
+ CD_LCF-->>Cluster1: 6) Response
+ Cluster1->>Cluster2: 7) Session request
+ Note over Cluster2: 8) Session setup
+ Cluster2-->>Cluster1: 9) Session response
+ Cluster1-->>SCF: 10) Session response
+ Note over End-user, SCF: 11) Session response
+(including resource submit, e.g., via RACF)
+ End-user->>Cluster1: 12) Stream control
+ Cluster1->>Cluster2: 13) Stream control
+ Cluster2-->>End-user: 14) Content stream
+
+```
+
+The diagram illustrates the sequence of operations for Case 2-1. It involves five main entities: End-user functions, SCF/IPTV AF, Cluster 1 (containing CCF and CDPF), CD & LCF, and Cluster 2 (containing CCF and CDPF). The process begins with a session request from the end-user to the SCF. The SCF then forwards this request to Cluster 1. Cluster 1 checks its serving capability and queries the CD & LCF for a new cluster. The CD & LCF allocates a new cluster and responds to Cluster 1. Cluster 1 then sends a session request to Cluster 2, which performs session setup. Cluster 2 returns a session response to Cluster 1, which then returns a session response to the SCF. The SCF sends a session response to the end-user. The end-user then sends stream control requests to Cluster 1, which forwards them to Cluster 2. Finally, Cluster 2 streams the content back to the end-user.
+
+Sequence diagram for Case 2-1: Content not available in cluster 1 and direct streaming from cluster 2. The diagram shows interactions between End-user functions, SCF/IPTV AF, Cluster 1 (CCF, CDPF), CD & LCF, and Cluster 2 (CCF, CDPF).
+
+Y.2019(10)\_F11.8
+
+Figure 11-8 – Case 2-1, Content not available in cluster 1 and direct streaming from cluster 2
+
+The procedure shown in Figure 11-8 contains the following steps:
+
+- 1) the procedure is triggered by an action from the end-user. The end-user requests content from the IPTV application function which results in a unicast session request from the end-user functions to the SCF;
+- 2) the SCF forward the service session request to the CCF of cluster 1;
+- 3) the CCF of cluster 1 check if they have the serving capability (e.g., if the requested content is available in the cluster, if the load is below a given threshold, etc.);
+- 4) if cluster 1 cannot supply the content, the CCF of cluster 1 send a query request to the CD&LCF in order to find an alternative cluster able to serve the end-user functions;
+- 5) the CD&LCF select an alternative cluster (referred to as cluster 2), which is capable of serving the end-user for the content. The selection follows policies such as those based on priorities or on the cluster status and/or load (e.g., number of outgoing streams), etc.;
+- 6) the CD&LCF return cluster 2 address to the CCF of cluster 1;
+- 7) the CCF of cluster 1 send the service session request to the CCF of cluster 2;
+- 8) the CCF of cluster 2 send the session request to the appropriate CDPF of cluster 2 and establish the content delivery session;
+- 9) the content delivery session identification is returned through the service session setup response to the CCF of cluster 1;
+- 10) the CCF of cluster 1 send the service session setup response to the SCF;
+- 11) the SCF forward the service session response to the end-user functions. Reserved resources are committed in this step;
+- 12) stream control requests generated by the end-user functions are targeted to the CCF of cluster 2;
+- 13) the CCF cache the stream control requests to the appropriate CDPF within cluster 2;
+- 14) the CDPF in cluster 2 stream the media directly to the end-user functions.
+
+NOTE – Steps 1 and 11 correspond to service control procedures (refer to [ITU-T Y.1910] for further guidance).
+
+##### **11.2.4.1.3 Case 2-2: Content not available in cluster 1 and streaming from cluster 2 through cluster 1**
+
+Figure 11-9 describes the procedure where cluster 1 does not contain the requested content although the load of cluster 1 is enough to serve the end-user. In this procedure, an alternative cluster supplies cluster 1 with the requested content.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant Cluster1 as Cluster 1
+CCF CDPF
+ participant Cluster2 as Cluster 2
+CD & LCF CCF CDPF
+
+ Note over End-user, SCF: 1) Session request
+(including resource reservation, e.g., via RACF)
+ SCF->>Cluster1: 2) Session request
+ Note over Cluster1: 3) Check if it has the serving capability
+ Note over Cluster1: 4) Session setup
+ Cluster1->>Cluster2: 5) Query the cluster which has the content
+ Cluster2-->>Cluster1: 6) Response
+ Cluster1->>Cluster2: 7) Content request
+ Cluster2->>Cluster2: 8) Content request
+ Cluster2-->>Cluster2: 9) Response
+ Cluster2-->>Cluster1: 10) Content download
+ Cluster1-->>SCF: 11) Response
+ SCF-->>End-user: 12) Session response
+ Note over End-user, SCF: 13) Session response
+(including resource submit, e.g., via RACF)
+ SCF->>Cluster1: 14) Stream control
+ Note over Cluster1: 15) Stream control
+ Cluster1-->>End-user: 16) Content stream
+
+```
+
+Sequence diagram showing the process of content streaming from Cluster 2 through Cluster 1. The diagram involves four main entities: End-user functions, SCF/IPTV AF, Cluster 1 (containing CCF and CDPF), and Cluster 2 (containing CD & LCF, CCF, and CDPF). The process starts with a session request from the end-user to the SCF/IPTV AF, which then forwards it to the CCF of Cluster 1. Cluster 1 checks its serving capability and sets up a session. It then queries the CD & LCF of Cluster 2 for content. Cluster 2 responds, and Cluster 1 requests the content from Cluster 2. Cluster 2's CCF requests the content from its CDPF, which responds. Cluster 1 then downloads the content and responds back to the SCF/IPTV AF. Finally, the SCF/IPTV AF sends a session response to the end-user and stream control messages to Cluster 1, which then streams the content to the end-user.
+
+Y.2019(10)\_F11.9
+
+**Figure 11-9 – Case 2-2, Content not available in cluster 1 and streaming from cluster 2 through cluster 1**
+
+The procedure shown in Figure 11-9 contains the following steps:
+
+- 1) the sequence is triggered by an action from the end-user. The end-user requests a content from the IPTV AF which results in a unicast session request from the end-user functions to the SCF;
+- 2) the SCF forward the service session request to the CCF of cluster 1;
+- 3) the CCF of cluster 1 check if they have the serving capability (e.g., if the request content is available in cluster 1 and if the load does not reach a given threshold, etc.);
+- 4) the CCF of cluster 1 send the session request to the appropriate CDPF within cluster 1 and set up the content delivery session;
+- 5) the CCF of cluster 1 send the query request to the CD&LCF to select a cluster(s) which has the requested content. Hereinafter, the selected cluster is referred to as cluster 2;
+- 6) the CD&LCF send the query result to the CCF of cluster 1;
+- 7) the CCF of cluster 1 send the content request to the CCF of cluster 2 to ask for the requested content;
+- 8) the CCF of cluster 2 send the request to an appropriate CDPF within cluster 2 for the requested content;
+
+- 9) the selected CDPF of cluster 2 send an acknowledgement back to the CCF of cluster 2;
+- 10) the CDPF of cluster 2 download the requested content to cluster 1 (to the previously selected CDPF within cluster 1);
+- 11) the CCF of cluster 2 respond to the CCF of cluster 1 to notify that the requested content has been supplied to cluster 1;
+- 12) the CCF of cluster1 send a service session setup response to the SCF;
+- 13) the SCF forward the service session response to the end-user functions. Reserved resources are committed in this step (e.g., via RACF as specified in [ITU-T Y.2111]);
+- 14) stream control requests generated by the end-user functions are targeted to the CCF of cluster 1;
+- 15) the CCF of cluster 1 cache the stream control requests to the appropriate CDPF;
+- 16) the CDPF stream the media directly to the end-user functions.
+
+NOTE 1 – Steps 1 and 13 correspond to service control procedures (refer to [ITU-T Y.1910] for further guidance).
+
+NOTE 2 – Step 10 allows to cache enough content in cluster 1 before content is streamed in step 16.
+
+#### 11.2.4.2 Multicast-based content delivery procedure
+
+The procedures in this clause cover optional requirement R11 (see clause 8.2).
+
+##### 11.2.4.2.1 Network multicast-based content delivery procedure
+
+Figure 11-10 shows the procedure for multicast-based content delivery procedure when CDPF serves as linear TV relay or linear TV multicast for multicast service (e.g., user generated content service, linear TV service).
+
+
+
+```
+
+sequenceDiagram
+ participant End-user functions
+ participant MTF
+ participant RACF
+ participant SCF
+ participant IPTV AF
+ participant CDPF
+
+ Note over End-user functions, MTF: 2) Session request (including resource reservation, e.g., via RACF)
+ Note over SCF, IPTV AF: 3) Service session setup request
+ Note over SCF, IPTV AF: 4) Service session setup response
+ Note over End-user functions, MTF: 5) Session response (including resource reservation, e.g., via RACF)
+ Note over End-user functions, MTF: 6) Join multicast
+ Note over SCF, IPTV AF: 7) Service session setup request
+ Note over SCF, IPTV AF: 8) Service session setup response
+ Note over End-user functions, MTF: 9) Media stream
+ Note over End-user functions, MTF: 10) Change channel
+ Note over SCF, IPTV AF: 11) Service session setup request
+ Note over SCF, IPTV AF: 12) Service session setup response
+ Note over End-user functions, MTF: 13) Media stream
+
+ End-user functions->>MTF: 2) Session request (including resource reservation, e.g., via RACF)
+ SCF->>IPTV AF: 3) Service session setup request
+ IPTV AF-->>SCF: 4) Service session setup response
+ SCF->>MTF: 5) Session response (including resource reservation, e.g., via RACF)
+ End-user functions->>MTF: 6) Join multicast
+ SCF->>IPTV AF: 7) Service session setup request
+ IPTV AF-->>SCF: 8) Service session setup response
+ IPTV AF-->>End-user functions: 9) Media stream
+ End-user functions->>MTF: 10) Change channel
+ SCF->>IPTV AF: 11) Service session setup request
+ IPTV AF-->>SCF: 12) Service session setup response
+ IPTV AF-->>End-user functions: 13) Media stream
+
+```
+
+The diagram illustrates the network-based multicast procedure. It involves six entities: End-user functions, MTF, RACF, SCF, IPTV AF, and CDPF. The procedure consists of 13 numbered steps. Steps 2, 5, and 13 are highlighted with grey bars. Step 1 is a media stream from CDPF to MTF. Steps 3 and 4 are service session setup requests and responses between SCF and IPTV AF. Steps 7 and 8 are service session setup requests and responses between SCF and IPTV AF. Steps 9 and 13 are media streams from IPTV AF to End-user functions. Steps 10 and 11 are service session setup requests and responses between SCF and IPTV AF. Steps 12 and 13 are media streams from IPTV AF to End-user functions.
+
+Sequence diagram illustrating the Network-based multicast procedure involving End-user functions, MTF, RACF, SCF, IPTV AF, and CDPF.
+
+Y.2019(1C)\_F11.10
+
+**Figure 11-10 – Network-based multicast procedure**
+
+- 1) the CDPF relay the multicast stream to the MTF. MTF include a multicast control point functional block (McCP-FB) and a multicast replication functional block (McR-FB), as defined in [ITU-T Y.1910];
+- 2) the end-user functions send a service session setup request to the SCF, including a media offer for the scheduled content service. The SCF reserve transport resources according to the media offer;
+- 3) the SCF forward the request to the IPTV AF, which check that the user is authorized for the service and has the rights to consume the content;
+- 4) the IPTV AF reply to the SCF with the bandwidth required for the specific scheduled content and can optionally retrieve other parameters;
+- 5) if the media offer has changed or new parameters are received, the SCF request admission control. Then the service session setup response is forwarded to the end-user functions;
+- 6) the end-user functions send a request to the MTF to join the multicast channel in order to view the content;
+- 7-8) an interaction between the MTF and RACF occurs in order to guarantee the needed bandwidth and QoS for the channel. This may happen in different cases, for example, when the multicast channel is not present at network access node to which the user is connected, or when end-user functions wish to join a multicast channel with different QoS requirements (e.g., zapping from a standard definition to a high definition channel);
+- 9) the media stream is forwarded to the end-user functions;
+- 10) the end-user functions send a request to the MTF to change the channel, i.e., join another multicast channel;
+- 11-13) the procedures are identical to those of steps 7-9.
+
+##### **11.2.4.2.2 Multicast within cluster-based content delivery procedure**
+
+When the network is not multicast capable, the CDPF can optionally also support similar functions such as multicast transport functions (MTF). In this case, the end-user functions interact with the CDPF to join the multicast channel.
+
+Figure 11-11 describes multicast within cluster-based content delivery procedure.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant Cluster1 as Cluster 1
+CCF, CDPF, MTF
+ participant Cluster2 as Cluster 2
+CCF, CDPF
+
+ Note over End-user, SCF: 1) Session request
+(including resource reservation, e.g., via RACF)
+ SCF->>Cluster1: 2) Session request
+ Note over Cluster1: 3) Check if it has the serving capability
+ Note over Cluster1: 4) Session setup
+ Cluster1-->>Cluster2: 5) Query the cluster which has the content
+ Note over Cluster2: 6) Content request
+ Note over Cluster2: 7) Response
+ Cluster2-->>Cluster1: 8) Content download
+ Note over Cluster1: 9) Response
+ Cluster1-->>SCF: 10) Session response
+ Note over End-user, SCF: 11) Session response
+(including resource commitment, e.g., via RACF)
+ SCF->>End-user: 12) Multicast join
+ SCF->>Cluster1: 13) Content flow
+ Cluster1->>End-user: 14) Content flow
+
+```
+
+Y.2019(10)\_F11.11
+
+Sequence diagram illustrating the Content delivery based multicast procedure. The diagram shows interactions between End-user functions, SCF/IPTV AF, Cluster 1 (CCF, CDPF, MTF), and Cluster 2 (CCF, CDPF).
+
+**Figure 11-11 – Content delivery based multicast procedure**
+
+NOTE 1 – It is assumed that multicast transport functions (MTF) are located in cluster 1. The MTF is an entity in the transport stratum which can optionally be located inside or outside of cluster 1, depending on the implementation choice. MTF include a multicast control point functional block (McCP-FB) and a multicast replication functional block (McR-FB), as defined in [ITU-T Y.1910].
+
+NOTE 2 – In Figure 11-11, cluster 1 may or may not have the requested content and it is delivered to end-users by means of multicast mechanism.
+
+- 1) the sequence is triggered by an action from the end-user. The end-user requests the content from the IPTV AF which results as a multicast session request from the end-user functions to the SCF;
+- 2) the SCF forward the service session request to the CCF of cluster 1;
+- 3) the CCF check if they have the serving capability e.g., if the requested content exists in cluster 1;
+- 4) the CCF of cluster 1 send the session request to the appropriate CDPF of cluster 1 and set up the content delivery session;
+- 5) the CCF of cluster 1 send the query request to the CCF of cluster 2 to supply the requested content;
+- 6) the CCF of cluster 2 send the request to the appropriate CDPF of cluster 2 for the requested content;
+- 7) the CDPF of cluster 2 send an acknowledgement to the CCF of cluster 2;
+
+- 8) the CDPF of cluster 2 download the requested content to the CDPF of cluster 1;
+- 9) the CCF of cluster 2 notify the CCF of cluster 1 that the requested content has been supplied;
+- 10) the CCF of cluster 1 send the service session setup response to the SCF;
+- 11) the SCF forward the service session response to the end-user functions. Reserved resources are committed in this step;
+- 12) the end-user joins the multicast channel;
+- 13-14) the content stored in cluster 1 is delivered to the end-user functions through the multicast channel.
+
+### 11.2.5 Procedures of user created content (UCC) upload and delivery
+
+The procedures cover optional requirement R10 (see clause 8.2).
+
+#### 11.2.5.1 Procedure for UCC upload
+
+Figure 11-12 describes the procedure of user created content upload.
+
+NOTE 1 – As an alternative to the procedure described in this clause, user created content (UCC) can be handled and delivered the same way as content provided by content provider functions, the user playing the role of a content provider [ITU-T Y.1910]. In such a scenario, UCC will be first handled by application functions, e.g., for content preparation functions (for further checking or processing by the IPTV service provider). Procedures defined for content ingestion (see clause 11.2.1), content dispatching (see clause 11.2.2), content aging (see clause 11.2.3) and content delivery (see clauses 11.2.4.1 and 11.2.4.2) will then be reused for UCC distribution and delivery.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant CD_LCF as CD & LCF
+ participant Cluster1 as Cluster 1
+CCF CDPF
+
+ Note over End-user, SCF: 1) Content upload session request
+(resource reservation, e.g., via RACF)
+ SCF->>CD_LCF: 2) Content upload session request
+ Note over CD_LCF: 3) Allocation of cluster
+ CD_LCF->>Cluster1: 4) Content upload session request
+ Note over Cluster1: 5) Content upload session setup
+ Cluster1->>CD_LCF: 6) Content upload session response
+ CD_LCF->>SCF: 7) Content upload session response
+ Note over End-user, SCF: 8) Content upload session response
+(resource commitment, e.g., via RACF)
+ Note over End-user, SCF, CD_LCF, Cluster1: 9) Content upload
+
+```
+
+The diagram illustrates the UCC upload procedure. It involves four main entities: End-user functions, SCF/IPTV AF, CD & LCF, and Cluster 1 (containing CCF and CDPF). The process begins with a content upload session request from the end-user to the SCF/IPTV AF (Step 1). The SCF/IPTV AF then forwards this request to the CD & LCF (Step 2). The CD & LCF performs an allocation of the cluster (Step 3) and then sends the request to Cluster 1 (Step 4). Cluster 1 performs a content upload session setup (Step 5) and sends a response back to the CD & LCF (Step 6). The CD & LCF then sends a response back to the SCF/IPTV AF (Step 7). The SCF/IPTV AF sends a final response to the end-user (Step 8). Finally, the content upload occurs (Step 9).
+
+Sequence diagram for UCC upload procedure showing interactions between End-user functions, SCF/IPTV AF, CD & LCF, and Cluster 1 (CCF, CDPF).
+
+Y.2019(10)\_F11.12
+
+**Figure 11-12 – UCC upload procedure**
+
+- 1) the sequence is triggered by an action from the end-user. The end-user requests the upload of content by means of a content upload session request from end-user functions to the SCF/IPTV AF; resources are reserved, e.g., via RACF;
+- 2) the SCF/IPTV AF forward the content upload session request to the CD&LCF;
+
+- 3) the CD&LCF allocate the appropriate cluster to receive the content according to the content upload session request, depending on information such as specific geographical location, the load of the clusters;
+NOTE 2 – Multiple clusters can optionally be allocated according to the content upload session request.
+- 4) the CD&LCF send the content upload session request to the CCF of the selected cluster 1;
+- 5) the CCF sends the content upload session request to the appropriate CDPF and set up the content upload session. The following actions are performed:
+ - i) the CCF send the content upload session request (e.g., RTSP DESCRIBE) to the selected CDPF;
+ - ii) the CDPF send the content upload session response to the CCF including information such as the storage path for the content;
+ - iii) the CCF set up the content upload channel (e.g., via RTSP SETUP) with the CDPF;
+ - iv) the CDPF confirm the establishment of the content upload session to the CCF including information such as the session identification;
+ - v) the CCF allocate resources according to the established content upload session;
+- 6) the content upload session identification is returned, through the content upload session response, from CCF back to the CD&LCF;
+- 7) the CD&LCF send the content upload session response to the SCF/IPTV AF;
+- 8) the SCF/IPTV AF forward the content upload session response to the end-user functions. Reserved resources are committed during this step, e.g., via RACF;
+- 9) content is uploaded by the end-user functions to the CCF according to the returned information received by the end-user functions. If content is uploaded using a streaming mode mechanism, then:
+ - i) the end-user functions send a content record request to the selected CCF;
+ - ii) the CCF send the content record request to the selected CDPF;
+ - iii) the CDPF send a content record response to the CCF;
+ - iv) the CCF send the content record response to the end-user functions. Then the CDPF record the content streamed from the end-user functions.
+
+NOTE 3 – Steps 1 and 8 correspond to service control procedures (refer to [ITU-T Y.1910]).
+
+#### **11.2.5.2 Procedure for UCC delivery**
+
+The procedure for UCC delivery follows the procedures for content delivery described in clause 11.2.4.
+
+### **11.2.6 Procedure of content delivery for content serving transfer**
+
+This procedure covers optional requirement R13 (see clause 8.2). The aim of content serving transfer is to maintain the quality of content delivery when the quality decreases because the end-user moves from one geographical area to another.
+
+Figure 11-13 describes the procedure of content delivery for content serving transfer.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user as End-user functions
+ participant SCF as SCF/IPTV AF
+ participant Cluster1 as Cluster 1
+CCF CDPF
+ participant CD_LCF as CD & LCF
+ participant Cluster2 as Cluster 2
+CCF CDPF
+
+ Note over End-user, SCF, Cluster1, CD_LCF, Cluster2: 1) Session establishment (including resource reservation, e.g., via RACF)
+ Note over End-user, Cluster1: 2) Content delivery
+ Note over SCF: 3) Detect the need of content serving transfer
+ Note over SCF, CD_LCF: 4) Content request
+ Note over CD_LCF: 5) Select new cluster serving the content
+ Note over CD_LCF, Cluster2: 6) Content response
+ Note over SCF: 7) Decision of session change
+ Note over SCF, CD_LCF: 8) Session change request
+ Note over CD_LCF: 9) Allocate cluster serving the content
+ Note over CD_LCF, Cluster2: 10) Session request
+ Note over Cluster2: 11) Session setup
+ Note over CD_LCF, Cluster2: 12) Session response
+ Note over SCF, CD_LCF: 13) Session change response
+ Note over End-user: 14) Session change
+ Note over End-user, Cluster1: 15) Stream control
+ Note over End-user, Cluster2: 16) Stream control
+ Note over End-user, Cluster2: 17) Stream control
+ Note over End-user, Cluster2: 18) Content stream
+ Note over End-user, SCF, Cluster1, CD_LCF, Cluster2: 19) Session termination
+
+```
+
+Sequence diagram illustrating the content delivery procedure for content serving transfer. The diagram shows interactions between End-user functions, SCF/IPTV AF, Cluster 1 (CCF, CDPF), CD & LCF, and Cluster 2 (CCF, CDPF).
+
+Y.2019(10)\_F11.13
+
+**Figure 11-13 – Content delivery procedure for content serving transfer**
+
+- 1) initial session is established between the end-user functions and the content delivery functions; a CDPF in cluster 1 is allocated for the content delivery session;
+- 2) the CDPF in cluster 1 stream the media to the end-user functions;
+- 3) SCF/IPTV AF detect a potential need of content serving transfer (e.g., due to a change of the end-user location);
+- 4) SCF/IPTV AF issue a content request to CD&LCF to request CD&LCF whether a new cluster can be allocated for the session;
+
+- 5) CD&LCF select cluster 2 as a candidate cluster for content serving transfer based on some parameters (e.g., the end-user location and delivery policy);
+NOTE 1 – Steps 4 and 5 allow the CD&LCF to check whether a candidate cluster is available for achieving the content serving transfer since this responsibility belongs to CD&LCF. Decision regarding the allocation of a new serving cluster is dependent upon SCF/IPTV AF subsequent decisions (see the following steps 7 and 8).
+- 6) CD&LCF return the cluster 2 address to SCF in the content response;
+- 7) the SCF/ IPTV AF decide whether to change the session established between the end-user functions and cluster 1;
+- 8) if the SCF decide to change the session, they forward a session change request to CD&LCF;
+- 9) the CD&LCF allocate the new serving cluster 2, which can optionally be one single serving cluster or multiple serving clusters with different serving priorities according to the delivery policy such as taking into account the delivery status, load (e.g., number of outgoing streams), etc.;
+- 10) the CD&LCF send the session request to the CCF in cluster 2;
+- 11) the CCF send the session request to the selected CDPF in cluster 2 and set up the content delivery session;
+- 12) the content delivery session identification is returned, through the service session setup response, to the CD&LCF. Session related information between the end-user functions and cluster 1 may be delivered to cluster 2 for the new session;
+- 13) CD&LCF send a session change response to the SCF;
+- 14) SCF notify the status of the new session to the end-user functions. The end-user functions perform the session change involving SCF. A new service session is established between cluster 2 and the end-user functions;
+- 15) stream control requests are generated by the end-user functions in order to terminate content delivery from cluster 1;
+- 16) stream control requests generated by the end-user functions are targeted to the selected CCF in cluster 2;
+NOTE 2 – End-user functions directly synchronize content delivered by cluster 1 and cluster 2 using stream control messages in steps 15 and 16.
+- 17) the CCF in cluster 2 forward the stream control requests to the selected CDPF;
+- 18) the CDPF in cluster 2 stream the content directly to the end-user functions;
+- 19) SCF terminate the service session with the original cluster 1.
+
+# **12 Security considerations**
+
+This Recommendation conforms to [ITU-T Y.2701] for security aspects. No specific security considerations have been identified.
+
+# Appendix I
+
+## Deployment model
+
+(This appendix does not form an integral part of this Recommendation)
+
+## I.1 Delivery deployment model
+
+IPTV services such as linear TV, video on demand (VoD), time-shift TV and network personal video recorder (nPVR) need content delivery mechanisms in the network. There are several models for content delivery and storage: client/server model, proxy instance model and hybrid model.
+
+- Client/server model: Media content delivers from multicast/unicast source to the end-user functions directly.
+- Proxy instance model: It consists of multiple proxy instances in which the content is stored and managed for consistency. Proxy instances are required to support linear TV relay when the network cannot support multicast.
+- Hybrid model: Proxy instances participate in the content delivery system as content source for caching and transfer. Proxy instances are required to support linear TV relay when the network cannot support multicast.
+
+## I.2 Client/server model
+
+Figure I.1 shows a client/server model. This model consists of a centralized node (CDPF or multicast source) sending contents to each end-user by unicast and multicast mode. For unicast, this model is not scalable due to limited network link capacity and server load capacities. For multicast, the content is delivered to each end-user function at the same time. This model achieves scalability by using multicast transmission, as illustrated in Figure I.2. This mode is usually used when the whole network can support multicast.
+
+
+
+The diagram shows a central node labeled 'C' at the top. Four arrows point downwards from node 'C' to four separate nodes labeled 'E' arranged in a horizontal row below. Below the diagram, the text reads: 'C - Unicast source' and 'E - End-user functions'.
+
+Y.2019(10)\_F1.1
+
+Diagram of a client/server model with unicast source.
+
+**Figure I.1 – Client/server model**
+
+
+
+The diagram shows a central node labeled 'M' at the top. Four arrows point downwards from node 'M' to four separate nodes labeled 'E' arranged in a horizontal row below. Below the diagram, the text reads: 'M - Multicast source' and 'E - End-user functions'.
+
+Y.2019(10)\_F1.2
+
+Diagram of a client/server model with multicast source.
+
+**Figure I.2 – Client/server model with multicast**
+
+## I.3 Proxy instance model
+
+A proxy instance model consists of several content delivery processing functions, including origin content storage instance and proxy node. Original content storage instances (i.e., unicast or multicast content source) deliver the content to adequate proxy instances in the network, and the proxy instances cache the content. If a proxy instance receives a content delivery request from end-user functions, the proxy instance delivers the content to the end-user functions. Caching mechanisms and period depend on parameters of availability, proximity, etc.
+
+Figure I.3 shows the proxy instance model, and when the content is delivered from content storage instance or proxy node, multicast source/relay transmission mechanisms can optionally be used, as illustrated in Figure I.4.
+
+
+
+```
+graph TD; C[C] --> P1[P]; C --> P2[P]; P1 --> E1[E]; P1 --> E2[E]; P2 --> E3[E]; P2 --> E4[E];
+```
+
+C - Unicast source
+P - Proxy storage node
+E - End-user functions
+
+Y.2019(10)\_F1.3
+
+Figure I.3: Proxy instance model diagram. A unicast source (C) connects to two proxy storage nodes (P). Each proxy storage node (P) connects to two end-user functions (E).
+
+**Figure I.3 – Proxy instance model**
+
+
+
+```
+graph TD; CM[C M] --> MP1[M P]; CM --> PM2[P M]; MP1 --> E1[E]; MP1 --> E2[E]; PM2 --> E3[E]; PM2 --> E4[E];
+```
+
+C - Unicast source
+M - Multicast source/relay node
+P - Proxy storage node
+E - End-user functions
+
+Y.2019(10)\_F1.4
+
+Figure I.4: Proxy instance model with multicast diagram. A unicast source (C) and a multicast source/relay node (M) connect to two proxy storage nodes (P). Each proxy storage node (P) connects to two end-user functions (E).
+
+**Figure I.4 – Proxy instance model with multicast**
+
+## I.4 Hybrid model
+
+Figure I.5 shows a hybrid model. The hybrid model is organized as a distributed network, using the resources of proxy instances. Proxy instances deliver totally or partially the requested content to requesting proxy instances or end-users. The end-user functions receive the content or send self-generated content. When the content is delivered from the proxy node, multicast source/relay transmission mechanisms can optionally be used, as illustrated in Figure I.6.
+
+
+
+```
+
+graph TD
+ P11[P] <--> P12[P]
+ P11 <--> P21[P]
+ P11 <--> P22[P]
+ P12 <--> P21
+ P12 <--> P22
+ P21 <--> P22
+ P11 --> E11[E]
+ P11 --> E12[E]
+ P12 --> E13[E]
+ P12 --> E14[E]
+ P21 --> E21[E]
+ P21 --> E22[E]
+ P22 --> E23[E]
+ P22 --> E24[E]
+
+```
+
+Diagram of the Hybrid model (Figure I.5). It shows a 2x2 grid of Proxy storage nodes (P). Each P node is connected to two End-user functions (E) above it and two E nodes below it. The P nodes are also interconnected in a mesh topology: horizontally, vertically, and diagonally.
+
+E - End-user functions
+P - Proxy storage node
+
+Y.2019(10)\_F1.5
+
+**Figure I.5 – Hybrid model**
+
+
+
+```
+
+graph TD
+ PM11[P M] <--> PM12[M P]
+ PM11 <--> PM21[P M]
+ PM11 <--> PM22[M P]
+ PM12 <--> PM21
+ PM12 <--> PM22
+ PM21 <--> PM22
+ PM11 --> E11[E]
+ PM11 --> E12[E]
+ PM12 --> E13[E]
+ PM12 --> E14[E]
+ PM21 --> E21[E]
+ PM21 --> E22[E]
+ PM22 --> E23[E]
+ PM22 --> E24[E]
+
+```
+
+Diagram of the Hybrid model with multicast (Figure I.6). It shows a 2x2 grid of nodes, each containing a Proxy storage node (P) and a Multicast source/relay node (M). Each P-M node is connected to two End-user functions (E) above it and two E nodes below it. The P-M nodes are also interconnected in a mesh topology: horizontally, vertically, and diagonally.
+
+E - End-user functions M - Multicast source/relay node
+P - Proxy storage node
+
+Y.2019(10)\_F1.6
+
+**Figure I.6 – Hybrid model with multicast**
+
+
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/14252bcd35912bd656e98b16b2ee51c0_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/14252bcd35912bd656e98b16b2ee51c0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..25e99f55c24d200c2e79f857f76414e5889907ce
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/14252bcd35912bd656e98b16b2ee51c0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:09b68fe86b1e18f62292d0a50c792b0be215e2867b229f78bfa1f23140d5b52d
+size 26831
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/329c96049bb432e9c2cbda4e224a0c9c_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/329c96049bb432e9c2cbda4e224a0c9c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..791844330be0520dafd275d6fe44c9f9baa091bc
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/329c96049bb432e9c2cbda4e224a0c9c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bcb02afcd06155a6766404106c1d6d5d42c192481f680242e012cc49f8277114
+size 60957
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6c3bb88055de3c074f1914757ef9887eb8ce3793
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/6629e8a87e7552e2454b7c3e9f6d73a0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6829622521c839e96d83660aa76f1b2ebb0e95b6a967bcf384b1a719070e53c0
+size 57234
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c08ca24fd65efcf1c72b3568835c16c6bb54ad0c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee5d84847fab5024d1d6f791616b61f8ac1bd1dd9e435395d1f391ebcda735dd
+size 72068
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ddc2d86595291397b6e9e8f6cbafc0364c5f7181
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bdd2ea26596b0a128c2e6f6216e4312884aa3acf2448cd3553f4604f94c06ead
+size 6552
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/8c880d6b715587bd710a9ba8414469b1_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/8c880d6b715587bd710a9ba8414469b1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8c558dd45b5b7b230a321524e4e65a4941d9417f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/8c880d6b715587bd710a9ba8414469b1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d0f8e21848d2a960e76a6556524e5fcdec700077705aac265955de0781d21ee6
+size 74861
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ac31fdfebb9751f7f10416dfe33bc872_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ac31fdfebb9751f7f10416dfe33bc872_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6516c174340f5bb61c781f3785fc8675dc260b13
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ac31fdfebb9751f7f10416dfe33bc872_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:75b5b9d5d1d47f02a3eeaa4040ca9410d049e550464976cd491d50879f6ca6f2
+size 47255
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c1e178259538cc7b5eda186fc475624ae2c36edd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/b58cedaf15ad4f0edee5621820865ccc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:653c5d54a0fc6ed64aa9906fdb4c5ae404353b602fcab28423e63fc013ffe4ed
+size 38011
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4fa58d6afa21653676354eb4a73c0b3dc11f2689
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:00b29d6137d3ee4da6d0e521e72ec99d484323431c18463863973f31178c83df
+size 121530
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/fa01531ea2c45beeb4036005da3037a4_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/fa01531ea2c45beeb4036005da3037a4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2bfccd32da21a20bf8310a8ee0756ae857d058c8
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/fa01531ea2c45beeb4036005da3037a4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d3f4ca310ebf422bab14443cfb1989e3d0531b6f29b80255767a5ba1a0c98203
+size 40751
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e07da2cf021d3d5cde4d1eb4b261ae566d43c3c1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5d5edf6241410422ed794457ea4e3bbc8b9b201741938ebd803be9420c762b4f
+size 22587
diff --git a/marked/Y/T-REC-Y.2061-201206-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..58532a8cd36151782db862a6886866ab50694d04
--- /dev/null
+++ b/marked/Y/T-REC-Y.2061-201206-I_PDF-E/raw.md
@@ -0,0 +1,1479 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.2061
+
+(06/2012)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Frameworks and functional
+architecture models
+
+---
+
+**Requirements for the support of machine-
+oriented communication applications in the next
+generation network environment**
+
+Recommendation ITU-T Y.2061
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with a red lightning bolt striking it, and the text "ITU" in blue, with "International Telecommunication Union" in smaller blue text below it.
+
+ITU logo
+
+# ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# **Recommendation ITU-T Y.2061**
+
+# **Requirements for the support of machine-oriented communication applications in the next generation network environment**
+
+## **Summary**
+
+Recommendation ITU-T Y.2061 provides an overview of machine-oriented communication (MOC) applications in the next generation network (NGN) environment. This includes the description of an MOC ecosystem, the characteristics of MOC and some relevant use cases. By analysing the service requirements of MOC applications, it specifies the requirements for NGN capabilities and the requirements of MOC-device domain capabilities based on these service requirements. Furthermore, this Recommendation provides a reference framework for MOC capabilities.
+
+## **History**
+
+| Edition | Recommendation | Approval | Study Group |
+|---------|----------------|------------|-------------|
+| 1.0 | ITU-T Y.2061 | 2012-06-15 | 13 |
+
+## **Keywords**
+
+Machine-oriented communication (MOC), MOC applications, MOC capabilities, MOC device, MOC-device domain, MOC gateway, MOC-service domain, NGN, NGN capabilities, NGN domain, service requirements.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2013
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|--------------------------------------------------------------------------|------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 3 |
+| 5 | Conventions ..... | 4 |
+| 6 | Introduction ..... | 4 |
+| | 6.1 Network overview ..... | 4 |
+| | 6.2 Types of machine-oriented communications..... | 6 |
+| | 6.3 MOC ecosystem ..... | 7 |
+| 7 | Characteristics of MOC ..... | 8 |
+| 8 | Service requirements of MOC applications..... | 9 |
+| | 8.1 Mobility levels..... | 9 |
+| | 8.2 Time controlled network communications..... | 9 |
+| | 8.3 Resource usage ..... | 10 |
+| | 8.4 Interoperability with proprietary devices ..... | 10 |
+| | 8.5 Application collaboration ..... | 10 |
+| | 8.6 Support of service integration and delivery environment ..... | 10 |
+| | 8.7 Load balancing and robustness..... | 11 |
+| | 8.8 Accounting and charging..... | 11 |
+| | 8.9 Management ..... | 11 |
+| | 8.10 Addressing and identification..... | 13 |
+| | 8.11 Location-based support ..... | 13 |
+| | 8.12 Group-based support ..... | 13 |
+| | 8.13 Quality of service ..... | 14 |
+| | 8.14 Security..... | 15 |
+| | 8.15 Device association and interaction with multiple applications ..... | 16 |
+| | 8.16 Communication with sleeping device ..... | 16 |
+| | 8.17 Differentiation and handling of collected data ..... | 16 |
+| 9 | Requirements of NGN capabilities..... | 17 |
+| | 9.1 Requirements for extensions or additions to NGN capabilities ..... | 17 |
+| | 9.2 Requirements supported by existing NGN capabilities..... | 20 |
+| 10 | Capability requirements of an MOC device domain ..... | 20 |
+| | 10.1 Application enablement..... | 20 |
+| | 10.2 Mobility ..... | 20 |
+| | 10.3 Communication ..... | 21 |
+
+| | Page |
+|-----------------------------------------------------------------|-------------|
+| 10.4 QoS ..... | 21 |
+| 10.5 Remote management ..... | 21 |
+| 10.6 Device addressing and identification..... | 22 |
+| 10.7 Security..... | 22 |
+| 10.8 Accounting and charging..... | 22 |
+| 10.9 Data identification ..... | 22 |
+| 11 Reference framework for MOC capabilities..... | 22 |
+| 11.1 High-level view ..... | 22 |
+| 11.2 MOC capabilities in the NGN domain ..... | 23 |
+| 11.3 MOC capabilities in the MOC device domain ..... | 26 |
+| 11.4 MOC service interfaces ..... | 27 |
+| 12 Security considerations ..... | 28 |
+| Appendix I – Actors and related roles in the MOC ecosystem..... | 29 |
+| Appendix II – MOC use cases ..... | 30 |
+| II.1 e-Health ..... | 30 |
+| II.2 Tsunami warning service..... | 32 |
+| II.3 Motorcade management ..... | 33 |
+| II.4 Smart home..... | 34 |
+| II.5 Integration with Internet services ..... | 35 |
+| Bibliography..... | 37 |
+
+# Recommendation ITU-T Y.2061
+
+## Requirements for the support of machine-oriented communication applications in the next generation network environment
+
+## 1 Scope
+
+This Recommendation covers extensions and additions to next generation networks as well as device capabilities in order to support machine-oriented communication (MOC) applications in the NGN environment. Although this Recommendation deals with the support of MOC applications in the NGN environment, these capabilities can conceptually be applicable to other networks.
+
+The scope of this Recommendation includes:
+
+- network overview; description of an MOC ecosystem and the characteristics of MOC
+- service requirements for the support of MOC applications
+- requirements of NGN capabilities based on MOC service requirements
+- requirements of MOC-device domain capabilities based on MOC service requirements
+- reference framework for MOC capabilities.
+
+NOTE – Appendix I provides details of actors and roles in an MOC ecosystem and Appendix II provides relevant use cases of MOC applications in the NGN environment.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Q.1706] | Recommendation ITU-T Q.1706/Y.2801 (2006), Mobility management requirements for NGN . |
+| [ITU-T Y.2012] | Recommendation ITU-T Y.2012 (2010), Functional requirements and architecture of next generation networks . |
+| [ITU-T Y.2060] | Recommendation ITU-T Y.2060 (2012), Overview of the Internet of things . |
+| [ITU-T Y.2201] | Recommendation ITU-T Y.2201 (2009), Requirements and capabilities for ITU-T NGN . |
+| [ITU-T Y.2221] | Recommendation ITU-T Y.2221 (2010), Requirements for support of ubiquitous sensor network (USN) applications and services in the NGN environment . |
+| [ITU-T Y.2233] | Recommendation ITU-T Y.2233 (2008), Requirements and framework allowing accounting and charging capabilities in NGN . |
+| [ITU-T Y.2240] | Recommendation ITU-T Y.2240 (2011), Requirements and capabilities for next generation network service integration and delivery environment . |
+| [ITU-T Y.2701] | Recommendation ITU-T Y.2701 (2007), Security requirements for NGN release 1 . |
+
+## 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 device** [ITU-T Y.2060]: With regard to the Internet of things, this is a piece of equipment with the mandatory capabilities of communication and the optional capabilities of sensing, actuation, data capture, data storage and data processing.
+
+**3.1.2 gateway** [ITU-T Y.2091]: A unit which interconnects different networks and performs the necessary translation between the protocols used in these networks.
+
+**3.1.3 ID terminal** [b-ITU-T Y.2213]: A device with a data reading and optional writing capability which reads (and optionally writes) identifier(s) and optionally application data from/into an ID tag.
+
+**3.1.4 network mobility** [ITU-T Q.1703]: The ability of a network, where a set of fixed or mobile nodes are networked to each other, to change, as a unit, its point of attachment to the corresponding network upon the network's movement itself.
+
+**3.1.5 NGN service integration and delivery environment (NGN-SIDE)** [ITU-T Y.2240]: An open environment in NGN integrating resources from different domains and delivering integrated services to applications over NGN.
+
+NOTE – These domains include, but are not limited to, a telecommunication domain (e.g., fixed and mobile networks), Internet domain, broadcasting domain and content provider domain.
+
+**3.1.6 open service environment capabilities** [ITU-T Y.2234]: Capabilities provided by an open service environment to enable enhanced and flexible service creation and provisioning based on the use of standards interfaces.
+
+**3.1.7 sensor** [ITU-T Y.2221]: An electronic device that senses a physical condition or chemical compound and delivers an electronic signal proportional to the observed characteristic.
+
+**3.1.8 universal IC card (UICC)** [b-ITU-T Q.1741.7]: A physically secure device, an IC card (or 'smart card'), that can be inserted and removed from the terminal. It may contain one or more applications. One of the applications may be a USIM.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines or uses the following terms:
+
+**3.2.1 actuator:** A device performing physical actions caused by an input signal.
+
+NOTE – As examples, an actuator might act on the flow of a gas or liquid, on electricity distribution, or through a mechanical operation. Dimmers and relays are examples of actuators. The decision to activate the actuator may come from an MOC application, a human or MOC devices and gateways.
+
+**3.2.2 machine-oriented communication (MOC):** A form of data communication between two or more entities in which at least one entity does not necessarily require human interaction or intervention in the communication process.
+
+**3.2.3 machine-oriented communication (MOC) capabilities:** A set of functions for the support and management of MOC applications, shared by different MOC applications and accessed through a set of standard interfaces.
+
+NOTE 1 – When MOC capabilities are supported by NGN, they provide standard interfaces for MOC applications to MOC devices and gateways for data collection, management and operation. They also reuse or interact with NGN capabilities [ITU-T Y.2201] [ITU-T Y.2240], IT capabilities or Internet capabilities to provide MOC applications.
+
+NOTE 2 – When MOC capabilities are supported by MOC devices and gateways, they interact with NGN functionalities and MOC applications through a set of standard interfaces.
+
+**3.2.4 machine-oriented communication (MOC) device:** A device involved in the support of MOC applications.
+
+NOTE – In the NGN environment, an MOC device connects with NGN directly or indirectly through an MOC gateway.
+
+**3.2.5 machine-oriented communication (MOC) end user:** An end user of MOC applications.
+
+NOTE – This end user may be a system (e.g., MOC application server, other network equipment, other applications, MOC device, MOC gateway), or a human (e.g., NGN end user).
+
+**3.2.6 machine-oriented communication (MOC) gateway:** A gateway which interconnects and provides interoperability between MOC local networks and the network, and where applicable, interoperability at the MOC application level.
+
+NOTE – In the NGN environment, an MOC gateway acts as a proxy or data aggregator to ensure interoperability and interconnection of MOC devices with the NGN.
+
+**3.2.7 machine-oriented communication (MOC) group:** A list of MOC devices and/or gateways grouped according to one or multiple criteria.
+
+NOTE – Criteria may include the MOC application subscriber, MOC device manufacturer, MOC application, or location.
+
+**3.2.8 machine-oriented communication (MOC) local network:** A network which provides connectivity between MOC devices without the intermediation of an MOC gateway, and between MOC devices and gateways.
+
+NOTE – An MOC local network may provide IP based and/or non-IP based connectivity.
+
+**3.2.9 meter:** A device that measures and optionally records the quantity, degree, or rate of something, especially the amount of electricity, gas or water used.
+
+NOTE – A meter is responsible for measuring the total amount of something consumed in a period.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|-------------------------------------|
+| ACI | Application to Capability Interface |
+| ANI | Application to Network Interface |
+| API | Application Programming Interface |
+| B2C | Business to Customer |
+| CDR | Charging Data Record |
+| GNSS | Global Navigation Satellite Systems |
+| GPS | Global Positioning System |
+| IC | Integrated Circuit |
+| ID | Identification |
+| IP | Internet Protocol |
+| IT | Information Technology |
+
+| | |
+|------|----------------------------------------------|
+| MOC | Machine-Oriented Communication |
+| NGN | Next Generation Network |
+| NNI | Network to Network Interface |
+| OSE | Open Service Environment |
+| QoS | Quality of Service |
+| SIDE | Service Integration and Delivery Environment |
+| SIP | Session Initiation Protocol |
+| SLA | Service Level Agreement |
+| SMS | Short Message Service |
+| SNS | Social Network Services |
+| UICC | Universal Integrated Circuit Card |
+| UNI | User to Network Interface |
+
+## **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this document is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement needs not be present to claim conformance.
+
+The keywords "can optionally" and "may" indicate an optional requirement which is permissible, without implying any sense of being recommended. These terms are not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# **6 Introduction**
+
+## **6.1 Network overview**
+
+Machine-oriented communications (MOC) are a form of data communications between two or more entities in which at least one entity does not necessarily require human interaction or intervention in the process of communication.
+
+MOC include communications with remote MOC devices for the support of procedures covering aspects such as registration, authentication, authorization, monitoring, maintenance, provisioning and troubleshooting. MOC applications intend to automate decision and communication processes.
+
+Figure 6-1 shows the network overview for the support of MOC applications in the NGN environment.
+
+
+
+Figure 6-1: Network overview for the support of MOC applications in the NGN environment. The diagram is divided into three horizontal domains: MOC service domain, NGN domain, and MOC device domain. In the MOC service domain, an 'MOC end user' (person at a computer) connects to 'MOC applications' (Motorcade management, Smart home, Intelligent transportation application, E-health, Tsunami warning service, Other MOC application). The NGN domain contains 'MOC capabilities' (Content management, Service dispatcher, Access control) and the 'NGN' cloud. The MOC device domain includes an 'MOC gateway' connected to an 'MOC local network' cloud, which in turn connects to various 'MOC devices' (Meter, Actuator, Identification terminal, Surveillance camera, Sensor, Mobile phone). Dashed lines indicate connections from MOC applications to MOC capabilities, and from MOC capabilities to the NGN cloud. Solid lines show connections from the MOC end user to the NGN cloud, and from the NGN cloud to the MOC gateway and directly to some MOC devices.
+
+Y.2061(12)\_F6-1
+
+**Figure 6-1 – Network overview for the support of MOC applications in the NGN environment**
+
+The MOC device domain includes MOC devices and MOC gateways. MOC devices include various types of devices as shown in Figure 6-1.
+
+NOTE 1 – Proprietary devices (see Figure 11-1) are not shown in the above figure.
+
+MOC devices can be categorized into general devices, data capturing devices, data carrying devices and sensing or actuating devices [ITU-T Y.2060]. Examples for the different categories include:
+
+- sensing or actuating devices: sensor, surveillance camera, meter, actuator with remote control;
+- data capturing devices and data carrying devices: identification terminal (ID terminal);
+- general devices: mobile phone, personal computer, networked television.
+
+MOC devices may access the NGN directly or via an MOC local network and the MOC gateways attached to it. MOC devices or gateways may access the NGN by use of wire-line or wireless connectivity.
+
+MOC devices and gateways may access NGN via multiple access networks, for example to ensure reliable communications.
+
+The NGN domain not only provides access, data transportation, network control and interconnection (with other networks) functions, but also provides MOC capabilities to support multiple MOC applications.
+
+MOC capabilities reuse or interact with NGN capabilities [ITU-T Y.2201], expose functionalities to MOC applications through a set of standard interfaces, provide support to facilitate application development and deployment through hiding network specificities to MOC applications. MOC capabilities include capabilities for content management, the service dispatcher and access control. Details can be found in clause 11.
+
+NOTE 2 – Although not shown in Figure 6-1, MOC capabilities in NGN can also interact with other applications outside the MOC service domain, such as social network services (SNS) or blog applications, which can make MOC related information available in accordance with customer or application requirements.
+
+The MOC service domain includes MOC applications. MOC applications run the application logic and use MOC capabilities accessible via standard interfaces.
+
+NOTE 3 – Although not shown in Figure 6-1, MOC capabilities and MOC applications can also exist in the MOC device domain.
+
+## **6.2 Types of machine-oriented communications**
+
+MOC covers communications among MOC devices and humans, specifically:
+
+- communications among different MOC devices and among MOC devices and MOC applications;
+- communications among MOC devices and other devices controlled by humans.
+
+The first type of communications deals with data collection, device management, device operations and other communication functions with remote equipment. These communications are used in many scenarios, e.g., that of MOC applications getting the relevant information provided by sensors.
+
+The second type of communications may be initiated by remote MOC devices to timely inform humans about relevant information detected in MOC devices, or may be initiated by humans to get relevant information from remote MOC devices. These communications involve many scenarios, e.g., a human connecting to a surveillance camera in his house by using a mobile phone.
+
+In the case of an MOC device interacting with MOC capabilities in a network domain or with MOC applications, the execution of an MOC application in an NGN environment may be divided into the following phases:
+
+- Data collection: the MOC device detects, measures and records data (e.g., data related to physical properties, multimedia data, etc.). When the MOC device meets a trigger threshold or receives an instruction from MOC capabilities in the network domain or MOC applications, the MOC device requests the NGN to transfer the data to the MOC application.
+
+NOTE 1 – The MOC device follows the pre-configured policy, which can be decided by the MOC capabilities or the MOC applications. According to the policy, the MOC device detects data, executes the logic, and initiates the communication to the MOC applications or human-controlled MOC devices to report the relevant information.
+
+- Data transportation: the NGN establishes a data path between the MOC device and the MOC capabilities. The MOC application can communicate with the MOC device directly (without gateway) under the authorization of the MOC capabilities in NGN: in order to manage the MOC device, the MOC application gets the authorization information from the MOC capabilities which are used for the secure communication's authorization and session key negotiation.
+
+NOTE 2 – The MOC device may also initiate such a process.
+
+- Data analysis: the MOC application analyses data received from the MOC device. MOC capabilities in NGN can also analyse the data based on rules defined by MOC end users.
+- Service delivery: the MOC application executes the service logic and decides how to publish the information to MOC end users (including MOC devices, humans or other applications). Information delivery can be "active" meaning that the MOC application forwards information to MOC end users automatically. The MOC application also supports forwarding the information based on demand from MOC end users ("passive" information delivery).
+
+NOTE 3 – Not all of the above phases are necessary for the execution of all MOC applications. For example, an MOC end user can send a request to a vehicle-related MOC application to turn on the klaxon of the vehicle when he/she wants to find out his/her vehicle in a large parking area, and the vehicle-related MOC application will turn on the vehicle klaxon after receiving the request. In this example, data collection and data transportation from the MOC device (the vehicle) to the MOC application are not executed.
+
+## 6.3 MOC ecosystem
+
+Figure 6-2 depicts business roles which are relevant in an MOC ecosystem, and their relationships. The business roles identified in Figure 6-2 and their relationships are based on the IoT ecosystem [ITU-T Y.2060] and adapted to the context of MOC.
+
+
+
+```
+graph LR; NP[Network provider] --- MPP[MOC platform provider]; MD[MOC device provider] --- MPP; MPP --- MAP[MOC application provider]; MAP --- MAC[MOC application customer];
+```
+
+The diagram illustrates the business roles in an MOC ecosystem. It features five rounded rectangular boxes representing different roles: 'Network provider' and 'MOC device provider' are on the left, connected by a vertical line. 'MOC platform provider' is in the center, connected to both 'Network provider' and 'MOC device provider' by horizontal lines. 'MOC application provider' is to the right of 'MOC platform provider', connected by a horizontal line. 'MOC application customer' is at the top right, connected to 'MOC application provider' by a vertical line. The identifier 'Y.2061(12)\_F6-2' is located at the bottom right of the diagram.
+
+Diagram of business roles in an MOC ecosystem showing relationships between Network provider, MOC device provider, MOC platform provider, MOC application provider, and MOC application customer.
+
+**Figure 6-2 – Business roles in an MOC ecosystem**
+
+Five key roles are identified: MOC application customer, network provider, MOC device provider, MOC platform provider and MOC application provider.
+
+- Network provider
+
+In the context of this Recommendation, the network provider is the role that offers the NGN capabilities as described in [ITU-T Y.2201].
+
+The network provider has a business relationship with the MOC platform provider and the MOC device providers.
+
+NOTE 1 – An actor playing the role of network provider can also play the roles of MOC platform provider, MOC device provider and MOC application provider.
+
+- MOC application provider
+
+The MOC application provider is the role providing functions in the MOC service domain. It utilizes capabilities provided by the MOC platform provider in order to provide services to the MOC application customer.
+
+The MOC application provider has a business relationship with the MOC application customer and the MOC platform provider.
+
+NOTE 2 – An actor playing the role of MOC application provider can also play the role of MOC platform provider.
+
+- MOC device provider
+
+The MOC device provider is responsible for providing functions in the MOC device domain. It provides raw data or other necessary resources to the network provider and the MOC platform provider according to the service logic.
+
+The MOC device provider has a business relationship with the MOC platform provider and the network provider.
+
+NOTE 3 – An actor playing the role of MOC device provider can also play the role of MOC application provider and the MOC platform provider.
+
+- MOC platform provider
+
+The MOC platform provider is the role responsible for providing the following functions in the NGN domain:
+
+- access to and integration of resources provided by MOC device providers and the network provider;
+- support and control of the service integration and delivery functionalities;
+- offering to the MOC application provider of capabilities (including resource exposure) for support of MOC applications.
+
+The MOC platform provider has a business relationship with the MOC device provider, the MOC application provider and the network provider.
+
+NOTE 4 – An actor playing the role of MOC platform provider can also play the role of MOC application provider and MOC device provider.
+
+- MOC application customer
+
+The MOC application customer may be a human or a device. The MOC application customer consumes applications offered by the MOC application provider. Organizations or persons such as enterprise, family or individuals are examples of MOC application customers.
+
+The MOC application customer has a business relationship with the MOC application provider. The MOC application customer is a subscriber of the MOC application provider.
+
+NOTE 5 – A given MOC application customer can represent multiple MOC end users in the MOC-service domain.
+
+Appendix I provides details of actors and roles in the MOC ecosystem.
+
+# **7 Characteristics of MOC**
+
+This clause provides the characteristics of MOC including those for applications, devices and gateways. Consideration should be given to the fact that these characteristics may vary across MOC applications, devices and gateways. These characteristics include, but are not limited to, the following:
+
+## **1) Variety of MOC device types and capability levels**
+
+There are various types of MOC devices for different uses; some of them have low performance and limited functionality (e.g., low processing capability, small memory, limited security capabilities), while others have powerful embedded capabilities (e.g., bilateral authentication and authorization capabilities with the network and MOC applications).
+
+### **2) MOC applications support of heterogeneous MOC devices**
+
+MOC applications may communicate with more than one type of MOC devices. In such cases, MOC applications need to cope with this heterogeneity.
+
+### **3) Grouping of MOC devices**
+
+In some use cases, groups of MOC devices are deployed for services. Usually, the MOC devices of a specific group have the same characteristics, functions, performance or policies.
+
+### **4) Variety of mobility levels of MOC devices and gateway**
+
+Some MOC devices and gateways are mobile and can be used everywhere. Some devices and gateway do not move. Some MOC devices and gateways move only within a certain area. Some MOC devices and gateways should not be moved once installed (their movement would mean theft of these devices has taken place).
+
+### 5) Remote management of MOC devices in varied and large deployments
+
+Massively deployed MOC devices cover large areas, they exist for a long time and they may be "moving", thus making it difficult for operators or MOC end users to manage all devices in the field.
+
+The remote management functionality of MOC devices (e.g., firmware updates) is particularly important in such deployments.
+
+### 6) Increased security threats from limited manual intervention
+
+Some MOC devices and gateways are required to be managed remotely rather than operated manually in the field. This increases the security threat level, such as physical tampering, hacking, and unauthorized monitoring and so on. So adequate security measures should be provided to detect or resist possible attacks.
+
+### 7) Variety of data communication characteristics
+
+Most MOC applications depend on data communications driven by machines without human interventions. The characteristics of such data communications are much different from human driven communications.
+
+The variety of data communications is also caused by the variability of other factors, such as packet size (small or large packets), data transmission periods and frequency or the MOC device communication role (initiating party or terminating party).
+
+### 8) Large amounts of data transmitted to the network
+
+With more and more intelligence embedded in devices and the large number of devices connected to the network, large amounts of data are transmitted to the network.
+
+## 8 Service requirements of MOC applications
+
+## 8.1 Mobility levels
+
+Different types of MOC applications may require different levels of MOC device and/or gateway mobility. This includes no mobility for devices and gateway that do not move, limited mobility for devices and gateway that move infrequently (e.g., medical devices on a patient may not move frequently), or low geographical mobility for devices and gateway that move only within a certain region (e.g., bus equipment devices such as a camera may move only within a city). It is needed to provide mobility management for different mobility levels in order to reduce resource usage (e.g., the timer of periodic location update should be reduced for the MOC devices which have infrequent movement).
+
+Requirements of mobility levels are as follows:
+
+- 1) MOC applications are required to be supported with optimized mobility management according to the required levels of mobility.
+
+### 8.2 Time controlled network communications
+
+In order to minimize costs and optimize network efficiency, MOC devices or MOC gateways can locally cache the collected data and transmit them to the network during the time slots allowed or pre-configured by the network operator.
+
+Requirements for time controlled network communications are as follows:
+
+- 1) MOC applications are recommended to support time control for MOC device communications with the network based on service criteria (e.g., daily network traffic load, MOC device location).
+
+### **8.3 Resource usage**
+
+MOC applications are expected to engage low resource usage in the case where MOC devices send or receive data infrequently (i.e., with a long time period between two data transmissions). To improve the operational efficiency of an MOC application and decrease the MOC application's operational costs and the MOC device's energy consumption, the resource usage of both MOC devices and networks need to be optimized.
+
+MOC applications requirements for optimized resource usage are as follows:
+
+- 1) MOC applications are recommended to optimize the usage of resources for both MOC devices and networks.
+
+NOTE – This is particularly relevant in the case of infrequent data transmissions.
+
+### **8.4 Interoperability with proprietary devices**
+
+Since a lot of proprietary devices (e.g., devices with proprietary standards for inter-working with network entities) have already been deployed, MOC applications should be able to support interoperability with these proprietary devices.
+
+Requirements for the support of proprietary devices are as follows:
+
+- 1) It is recommended that MOC applications be interoperable with proprietary devices through appropriate means, e.g., MOC gateways.
+- 2) MOC applications are recommended to support the effective hiding of proprietary devices' operations.
+
+### **8.5 Application collaboration**
+
+For some MOC application cases, there may be multiple MOC application providers providing different MOC applications which need to collaborate with each other.
+
+As an example, business to customer (B2C) companies deliver products to logistics companies for further delivery to the customers who have ordered them. Logistics companies track the products in transit, while customers may check the whereabouts of the purchased products by visiting the application systems of the B2C companies which collaborate with the application systems of the logistics companies.
+
+MOC applications requirements for application collaboration are as follows:
+
+- 1) MOC applications are recommended to support application collaboration with other MOC applications via the intermediation of the MOC capabilities.
+- 2) MOC applications of a given MOC application provider are recommended to support application collaboration with MOC applications of other MOC application providers via the intermediation of the MOC capabilities.
+
+### **8.6 Support of service integration and delivery environment**
+
+MOC applications would benefit from support by the network of a service integration and delivery environment. In addition to the support of common purpose capabilities for different types of applications, interfaces to such an environment would enable the support of specific capabilities for MOC applications.
+
+MOC application requirements for the support of service integration and a delivery environment are as follows:
+
+- 1) MOC applications are recommended to be able to access service integration and delivery environment capabilities provided by the network.
+
+NOTE – Access to such an environment also provides access to application development and testing capabilities.
+
+### **8.7 Load balancing and robustness**
+
+In some application cases, e.g., in a river control application with the water level of the river reaching the alert threshold, a large number of monitor points may send alert information to the MOC capabilities in the NGN domain, including the possibility to send real-time video. Such emergency scenarios require robustness of the network and MOC capabilities in the NGN domain.
+
+The distribution of MOC devices across territories and the density of MOC devices in a certain area may be high or low. This may cause an imbalance in the network and MOC capabilities in the NGN domain for both signalling and data traffic.
+
+In order to support network and MOC platform load balancing and robustness, the requirements are as follows:
+
+- 1) MOC applications require mechanisms in the network and MOC capabilities in the NGN domain for load balancing.
+- 2) MOC applications require a robust network and MOC capabilities in the NGN domain, whilst also ensuring a sufficient level of QoS under given circumstances, e.g., emergency scenarios.
+
+### **8.8 Accounting and charging**
+
+Different charging and accounting requirements need to be addressed depending on the scenarios of the MOC applications. For example, there are MOC applications with frequency data transmission and small amounts of data, in this case charging and accounting may be based on the number of communications. Some other MOC applications may rarely connect to the network but generate large amounts of data for each communication, in this case charging and accounting may be based on the amount of data. In other cases, charging and accounting may be based on the duration of communications.
+
+As an MOC application may use multiple devices for a single customer, charging per device by MOC application providers or network providers would generate a lot of charging data records (CDR) that impose a heavy load on some functions, e.g., the charging function. In these scenarios, group-based accounting and charging instead of per device accounting and charging may be more appropriate.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are required to support different charging and accounting methods, such as charging based on the duration of communications, number of communications, amount of transmitted data, etc.
+- 2) MOC applications are recommended to support unified charging for customers.
+- 3) When group-based support is enabled (see clause 8.12), MOC applications are required to support online and offline accounting and charging based on groupings.
+
+### **8.9 Management**
+
+#### **8.9.1 Device management**
+
+MOC devices cover a large area, exist for a long time and could be "on the move", so it may be difficult for operators or subscribers to manage these devices manually. Thus, MOC devices and gateways should be managed and monitored remotely (for example, updating the firmware to correct faults).
+
+MOC devices with a universal integrated circuit card (UICC) may be deployed outdoors without human supervision and it might happen that a given UICC is put into another device without permission of the UICC owner. Thus, in order to avoid such issues, the change of association between an MOC device and UICC should be accessible by MOC applications interacting with those MOC devices.
+
+When MOC devices and gateways provide service logic, the MOC devices and gateways provide support capabilities for both the customer and the service. MOC devices and gateways are required to be managed in terms of both network and service management.
+
+The requirements of MOC device management are as follows:
+
+- 1) MOC applications are required to support mechanisms for managing gateways acting as traffic aggregators (a gateway aggregates traffic and acts as a channel).
+- 2) MOC applications are required to monitor the state of various aspects of MOC devices and gateways including:
+ - a) abnormal behaviour of MOC devices and gateways, such as an active service not being aligned with the subscribed feature;
+ - b) the association between the MOC devices and gateways and the UICC;
+ - c) the attachment information of MOC devices and gateways, such as attachment location;
+ - d) the connectivity of MOC devices and gateways.
+- 3) MOC applications are required to support mechanisms to perform simple and scalable pre-provisioning of MOC devices and gateways, enable and disable features, report errors from devices, and query device status.
+- 4) MOC applications are required to support mechanisms to perform software upgrades (e.g., provisioning of new service logic and/or bug fixes to be loaded on devices and/or gateways, including applications and system software).
+- 5) MOC applications are required to manage low capability MOC devices using lightweight mechanisms.
+
+#### **8.9.2 Service profile management**
+
+The service profile of a specific MOC application is composed by a set of information specific to that MOC application. It may include, but it is not limited to, the MOC application identifier, MOC application provider identifier and application data types.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are recommended to use standard service profiles for registration and discovery.
+- 2) MOC applications are required to support mechanisms to perform service profile updates.
+
+#### **8.9.3 Device profile management**
+
+The MOC device profile is a set of information related to MOC devices and MOC gateways. As there are various types of MOC devices and MOC gateways, the device profiles are helpful in the management of large numbers of heterogeneous devices and gateways.
+
+NOTE 1 – The MOC device profile information may include an MOC device identifier, MOC device type, MOC device capabilities and MOC device location.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are recommended to use and manage standard device profiles for MOC devices and gateways, including their registration and discovery.
+
+NOTE 2 – Device profile management includes the creation of associations between MOC devices (gateways) and service profiles.
+
+### **8.10 Addressing and identification**
+
+There are two types of connection methods between MOC devices and MOC applications. MOC devices may connect to MOC applications directly or via MOC gateways based on IP connectivity. Different MOC devices may communicate with different MOC applications via a single MOC gateway or via multiple gateways.
+
+NOTE – The multiple gateways scenario allows the reduction of an MOC gateways' load and the growth of the network access reliability.
+
+MOC devices may support public or private IP addresses and may also support non-IP addresses when they connect to the network via MOC gateways. MOC application servers and MOC devices which are using public IP addresses should be able to communicate with other MOC devices which are using private IP addresses.
+
+The requirements of addressing and identification are as follows:
+
+- 1) MOC applications are required to be able to operate with different types of MOC device addressing schemes, e.g., IP addressing and non-IP addressing schemes.
+- 2) MOC applications require the support of unique identification of MOC devices.
+- 3) MOC applications require the support of unique identification of MOC groups (see clause 8.12 for description of an MOC group).
+- 4) MOC applications require the support of addressing mechanisms enabling communication with MOC devices behind an MOC gateway.
+- 5) MOC applications require the support of addressing mechanisms enabling communication with MOC gateways.
+- 6) MOC applications require the support of unique identification of MOC gateways.
+
+### **8.11 Location-based support**
+
+Location data may be collected by MOC applications from MOC devices and gateways or from the network. Types of location information include global navigation satellite systems (GNSS), latitude or longitude data or cell identifier (CellID).
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are required to be aware of the location of MOC devices. For example, based on the location information of MOC devices, the MOC application could initiate a service trigger to upgrade the firmware on the MOC devices within a certain area by the broadcast or multicast method.
+- 2) MOC applications are recommended to maintain and manage location information of both a single MOC device and a set of MOC devices behind an MOC gateway.
+- 3) MOC applications are recommended to maintain and manage different types of location information.
+
+### **8.12 Group-based support**
+
+MOC groups may be used in many MOC applications. For example, a vehicle company owner could manage the company vehicles in groups, e.g., track the locations of all the vehicles in the group and send notification messages to all the vehicles in the group. An electricity company could collect the metering data of all the MOC devices in a certain area at a certain time. A consumer could query the different meters at his home when he is on a business trip.
+
+Different MOC applications may have different MOC groups.
+
+MOC applications may have static MOC groups which are pre-configured, for example the consumer could pre-configure the MOC devices installed at his home into an MOC group. MOC applications may also have dynamic groups which are grouped according to some on-demand criteria, for example a vehicle company owner may request to communicate with all the vehicles in a certain area when needed.
+
+The MOC devices inside a group may directly connect to the network or indirectly connect to the network.
+
+The requirements for group-based support are the following:
+
+- 1) MOC applications require the support of static and dynamic MOC groups.
+- 2) MOC applications require the support of data transmission to/from one or all members in an MOC group using group identifier.
+- 3) MOC applications require the support of the group based QoS policy.
+- 4) MOC applications require the support of group based traffic parameters.
+- 5) MOC applications require the support of MOC group management, including display/creation/modification/deletion of MOC groups and associated attributes and display/addition/modification/deletion of MOC group members.
+- 6) MOC applications are recommended to be able to send data per MOC group and apply data prioritization according to member's data prioritization in the MOC group.
+
+### **8.13 Quality of service**
+
+#### **8.13.1 Application traffic control**
+
+The application traffic is not only generated by MOC devices, but also generated by MOC applications.
+
+MOC applications often cover a large number of MOC devices and gateways. In such scenarios, from the viewpoint of applications, their QoS may be impacted by high application traffic.
+
+From the viewpoint of the network, the QoS of MOC applications may be improved if the application traffic is well managed.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications require mechanisms for application traffic management, e.g., to limit the maximum number of application transactions per second.
+- 2) MOC applications require that access concentration into a single resource is avoided.
+
+#### **8.13.2 Data prioritization**
+
+The MOC mission-critical applications should be carefully managed. For example, emergency notification of a fire incident must be delivered in a timely and reliable way to the appropriate national disaster monitoring systems. In order to provide alarm notifications, the emergency data are carried over the network.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are recommended to be able to set the prioritization of data (within a single application or among different applications).
+- 2) MOC applications are recommended to be able to manage different data according to their prioritization.
+- 3) MOC applications are recommended to be able to apply data prioritization to MOC devices and gateways according to the related service level agreements (SLA) between MOC application customers and MOC application providers.
+
+### **8.14 Security**
+
+#### **8.14.1 Authentication and authorization**
+
+The MOC end users accessing the MOC applications need to be authenticated and authorized. Access to applications has to align with the relevant security levels.
+
+The MOC devices involved in the MOC applications and directly connected need to be authenticated and authorized.
+
+The MOC devices involved in the MOC applications and connected via an MOC gateway should generally be authenticated and authorized.
+
+Requirements of authentication and authorization are as follows:
+
+- 1) MOC applications are required to support the authentication and authorization of MOC end users to access MOC applications and related data according to the related security levels.
+- 2) MOC applications are required to support a mechanism for authentication and authorization of directly connected MOC devices associated with the MOC applications themselves.
+- 3) MOC applications are recommended to support a mechanism for authentication and authorization of MOC devices which are in an MOC local network (connected via an MOC gateway) and which are associated with the MOC applications themselves.
+- 4) MOC applications are required to support a mechanism for the registration of directly connected MOC devices associated with the MOC applications themselves.
+
+#### **8.14.2 Security of data**
+
+In general, MOC applications require strong security, due to very sensitive data. It has to be considered that MOC devices cannot provide all security features because they may have system limitations. For example, sensed data carried over the network may not be sufficiently protected from the security viewpoint.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are required to provide security for the connectivity between MOC applications and MOC devices even when the MOC devices roam from one network domain to another network domain.
+- 2) MOC applications are required to support the integrity and confidentiality of the data exchanged during the application operations.
+- 3) MOC applications are recommended to provide mechanisms of data encryption in order to also support MOC devices with limited capabilities.
+
+#### **8.14.3 Security of MOC device access**
+
+All data produced by MOC devices are required to be unknown to unauthorized entities. For example, private or sensitive data of an MOC device should not be sent to an unauthenticated end user if this end user initiates a communication with that MOC device.
+
+Due to the limited capabilities of the MOC devices with no support of authentication and authorization functionalities, MOC applications have the following requirements:
+
+- 1) Before MOC device resources can be used by MOC end users and MOC applications, MOC applications are required to support mechanisms for the authentication and authorization of MOC end users and MOC applications for their access to MOC device resources.
+
+### **8.15 Device association and interaction with multiple applications**
+
+In some application scenarios, a single MOC device may be required to communicate with different MOC applications simultaneously. For example, when a traffic accident happens, the damaged vehicle may be required to provide information to both the health service centre and the department for traffic control.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are required to not prevent the delivery of information to other MOC applications by an MOC device or gateway associated with that MOC application.
+- 2) MOC applications are required to not prevent an MOC device or gateway associated with that MOC application to receive information from other MOC applications.
+
+NOTE – In this Recommendation, it is assumed that the capability of an MOC device or gateway to communicate with multiple applications is controlled by the network (i.e., NGN). Requirements of an MOC device or gateway with "network control independent capability" to communicate with multiple applications are for further study.
+
+### **8.16 Communication with sleeping device**
+
+In the case of offline status for a given period of time, MOC devices enter or stay in sleep mode in order to:
+
+- save power, especially for devices using a battery
+- save network resources, especially for devices with wireless network access.
+
+NOTE – Sleep mode is an energy-saving mode. It normally refers to an MOC device in a situation when, traffic is not being generated for a period of time, device sessions and related traffic channels are released to save resources, and all unnecessary components are shut down. According to certain criteria, an MOC device in offline status can enter sleep mode.
+
+MOC applications have the following requirements:
+
+- 1) MOC applications are recommended to be able to send instructions to a sleeping MOC device to wake it up.
+- 2) MOC applications are required to support network-initiated communications towards a sleeping MOC device.
+
+### **8.17 Differentiation and handling of collected data**
+
+With the large variety of data collected by MOC devices being transmitted in the network, it is expected that the network be able to differentiate particular collected data from other data, and then trigger the relevant processes based on their category. For example, the network may cache and only later forward data which are collected in non-network performance sensitive applications. On the other hand, the network is required to immediately transmit high priority data which are collected in network performance sensitive applications.
+
+MOC applications requirements for collected data differentiation and related handling are as follows:
+
+- 1) MOC applications are required to enable the identification and categorization of the data collected by MOC devices according to relevant policies.
+- 2) If the network can handle data collected by MOC devices according to relevant data categorization, MOC applications are required to manage these data accordingly.
+
+# **9 Requirements of NGN capabilities**
+
+## **9.1 Requirements for extensions or additions to NGN capabilities**
+
+This clause identifies extensions or additions to NGN capabilities defined in [ITU-T Y.2201] for the support of MOC applications.
+
+#### **9.1.1 Numbering, naming and addressing**
+
+NGN provides addressing and identification capabilities. The service requirements specified in clause 8.10 are supported by the existing capabilities of NGN [ITU-T Y.2201] [ITU-T Y.2702].
+
+Based on the service requirements in clause 8.12, NGN is required to support the following additional numbering, naming and addressing requirements.
+
+- 1) An NGN is required to provide group based addressing mechanisms for the support of MOC applications according to the NGN provider's policy.
+- 2) An NGN is required to support a static MOC grouping capability.
+
+NOTE 1 – A static MOC group contains the members of the MOC devices and gateway which are pre-configured.
+
+- 3) An NGN is required to support a dynamic MOC grouping capability.
+
+NOTE 2 – A dynamic MOC group may be generated upon request using specific criteria, such as location, status of MOC devices and gateway, etc.
+
+- 4) An NGN is required to support the MOC grouping capability in both cases of groups constituted by MOC devices and gateway directly or indirectly connected to NGNs.
+- 5) An NGN is required to map the MOC group identifier to network addresses of MOC devices and gateways of a static MOC group.
+- 6) An NGN is required to identify the list of MOC devices and gateways and their network addresses matching the specified criteria for a dynamic MOC group.
+
+#### **9.1.2 Quality of service**
+
+The differentiated quality of service and data prioritization requirements, specified in clause 8.13 are supported by the existing capabilities of NGN [ITU-T Y.2201] [ITU-T Y.2221]. The following subclauses identify the requirements for extensions to NGNs.
+
+##### **9.1.2.1 Per group QoS policy**
+
+Based on the service requirements in clause 8.12, the following additional requirements are placed on NGNs:
+
+- 1) An NGN is required to support a per group level QoS policy, in parallel with, or instead of, a per device level QoS policy.
+
+NOTE – Per group QoS policy parameters include, but are not limited to:
+
+- packet transfer delay
+- packet delay variation
+- packet loss ratio
+- packet error ratio.
+
+##### **9.1.2.2 Traffic control**
+
+NGNs provide processing and traffic management capabilities. The service requirements specified in clause 8.7 are supported by the existing capabilities of NGN [ITU-T Y.2201].
+
+Based on the time controlled network communication requirements defined in clause 8.2, the following additional requirements are placed on NGNs:
+
+- 1) An NGN is required to allow MOC end users' access (e.g., attachment to the network or establishment of a data connection) during a defined granted network communication access time interval.
+- 2) An NGN is required to reject MOC end users' access (e.g., attachment to the network or establishment of a data connection), or allow it with different charging parameters, during a defined forbidden network communication access time interval.
+- 3) An NGN is required to allow the modification of granted network communication access time intervals based on service criteria (e.g., daily network traffic load, MOC device location).
+- 4) An NGN is required to communicate granted network communication access time schedules and durations to MOC devices and gateways.
+- 5) An NGN is required to terminate MOC end users' access (e.g., detachment from the network or release of a data connection) when a network communication access time duration has ended.
+- 6) An NGN can optionally support the communication of granted network communication access time schedules and durations to other MOC end users than the MOC devices and gateway (e.g., MOC application server).
+
+Based on the resource usage requirements in clauses 8.3 and 8.16, the following additional requirements are placed on NGNs:
+
+- 7) An NGN is required to page the target MOC devices and gateways before service interaction when the network needs to initiate a service.
+- 8) An NGN is required to establish communication resources only when data transmission is required.
+
+Based on the requirements in clause 8.12, in addition to the existing NGN traffic control capabilities, an NGN is required to support:
+
+- 9) optimized handling of group communications in order to save network resources and to prevent network congestion;
+- 10) per group level traffic control in parallel with, or instead of, per device level traffic control.
+
+NOTE – Per group level traffic parameters include, but are not limited to:
+
+- maximum allowed packet size
+- data rate and the bucket size
+- peak rate and peak bucket size
+- sustainable rate and sustainable bucket size.
+
+#### **9.1.3 Accounting and charging**
+
+Based on the service requirements in clause 8.8, the following additional requirements are placed on NGNs [ITU-T Y.2233]:
+
+- 1) An NGN is required to support group-based accounting and charging for either or both online charging and offline charging in parallel with, or instead of, per device level charging.
+
+#### **9.1.4 Mobility**
+
+NGNs provide mobility support for end users, MOC devices and gateways [ITU-T Y.2201] [ITU-T Q.1706].
+
+Based on the mobility levels in clause 8.1, the following additional requirements are placed on NGNs:
+
+- 1) An NGN is required to support pre-defined mobility levels for MOC devices and gateways via the device profile management.
+- 2) An NGN is required to support different mobility level management according to the mobility requirements of MOC devices and gateways, such as reducing the frequency of the mobility management procedures for MOC devices and MOC gateways with low mobility.
+- 3) An NGN is recommended to support dynamical instruction of the MOC devices and gateway in order to set the mobility level (implying, for example, the adjustment of the frequency of mobility management procedures).
+
+#### **9.1.5 Profile management**
+
+#### **9.1.5.1 User profile management**
+
+Based on the service requirements in clause 8.9.2, the following requirement is placed on NGNs:
+
+- 1) An NGN is recommended to support standard service profiles with enhancements for MOC applications' specific information.
+
+#### **9.1.5.2 Device profile management**
+
+Based on the service requirements in clause 8.9.3, the following requirement is placed on NGNs:
+
+- 1) An NGN is recommended to support standard device profiles with enhancements for MOC devices and gateway's specific information.
+
+#### **9.1.6 Device management**
+
+Based on the service requirements in clause 8.9.1, NGN is required to support the following additional device management requirements:
+
+- 1) An NGN is required to be able to manage and control MOC devices and gateways, including:
+ - a) monitoring MOC devices and gateways' operations;
+ - b) where applicable, monitoring changes, and related actions, in the associations between MOC devices or the gateway and UICCs;
+ - c) monitoring changes, and related actions, related to the network attachment points of MOC devices and gateways;
+ - d) monitoring MOC devices and gateways' network connectivity.
+
+#### **9.1.7 Data differentiation and handling**
+
+Based on the requirements of differentiation and handling of collected data in clause 8.17, the following additional requirements are placed on NGNs:
+
+- 1) An NGN is recommended to be able to identify data according to relevant categories.
+- 2) An NGN is recommended to apply different data handling (e.g., caching and/or forwarding) based on data identification.
+
+#### **9.1.8 Application collaboration and environment for service integration and delivery**
+
+Based on the service requirements specified in clauses 8.5 and 8.6, the following additional requirements are placed on NGNs:
+
+- 1) An NGN is required to provide capabilities for application collaboration and for a service integration and delivery environment.
+
+NOTE – [ITU-T Y.2240] capabilities may be used for the support of such requirements.
+
+### **9.2 Requirements supported by existing NGN capabilities**
+
+Based on the service requirements in clause 8, this clause specifies requirements supported by existing NGN capabilities for the support of MOC applications.
+
+#### **9.2.1 Group management**
+
+The group management requirements specified in clause 8.12 are supported by the existing capabilities of NGN [ITU-T Y.2201].
+
+### **9.2.2 Location management**
+
+NGN provides the location management capability which determines and reports information regarding the location of users and devices within the NGN. The location management requirements specified in clause 8.11 are supported by the existing capabilities of NGNs [ITU-T Y.2201].
+
+#### **9.2.3 Security**
+
+An NGN provides security capabilities. The service requirements specified in clause 8.13 are supported by the existing capabilities of NGNs [ITU-T Y.2201] [ITU-T Y.2701].
+
+#### **9.2.4 Group related communication modes**
+
+Based on the service requirements in clause 8.12, an NGN is required to support the following communication modes for MOC groups (with MOC devices and gateways directly or indirectly connected to NGNs):
+
+- any cast
+- multicast
+- broadcast.
+
+These requirements are supported by the existing capabilities of NGNs [ITU-T Y.2201].
+
+# **10 Capability requirements of an MOC device domain**
+
+This clause identifies the capability requirements of an MOC device domain for the support of MOC applications.
+
+## **10.1 Application enablement**
+
+Based on the requirements in clause 8.4, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC devices are recommended to support a set of abstracted operations.
+- 2) MOC devices are recommended to support the implementation of service logic to provide MOC capabilities.
+- 3) MOC gateways can optionally support a set of abstracted operations on MOC devices.
+- 4) MOC gateways can optionally support the implementation of service logic to provide MOC capabilities.
+
+### **10.2 Mobility**
+
+Based on the requirements in clause 8.1, the following requirements apply to the MOC gateway and device's capabilities:
+
+- 1) MOC gateways and MOC devices are required to support enhanced mobility management capabilities in order to support different levels of mobility.
+
+### 10.3 Communication
+
+Based on the requirements in clauses 8.2, 8.3 and 8.4, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC gateways and MOC devices are required to be able to establish, maintain or release communication resources according to the data communication needs.
+- 2) MOC gateways are required to be able to select the proper routing paths between the traffic originating endpoint (MOC devices or MOC application server) and the traffic receiving endpoint (MOC devices or MOC application server) according to the application the MOC device is associated with or vice versa.
+- 3) MOC gateways are required to allow the setting and modification of granted/forbidden network communication access time schedules and durations.
+- 4) MOC gateways are required to support the following communication modes according to the service requirements:
+ - any cast
+ - multicast
+ - broadcast.
+- 5) MOC gateways are recommended to support communication with proprietary devices (e.g., devices with proprietary interfaces for inter-working with network entities).
+- 6) MOC devices are required to go offline when no data transmission is required and then to go into sleep mode according to the necessary policies.
+NOTE – The transition to sleep mode can also be controlled by the network.
+- 7) MOC devices can optionally support communication with the network according to the following criteria: daily network traffic load, MOC device location, access time schedules and durations.
+
+### 10.4 QoS
+
+Based on the requirements defined in clauses 8.2 and 8.13, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC gateways and MOC devices are required to support the traffic control policy which defines granted network communication access time schedules and durations.
+- 2) MOC gateways and MOC devices are required to support QoS differentiation according to different categories of traffic.
+- 3) MOC gateways and MOC devices are required to provide performance measurement and management.
+- 4) MOC gateways and MOC devices are recommended to support application prioritization.
+
+### 10.5 Remote management
+
+Based on the requirements in clause 8.9.1, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC gateways are required to act as a management proxy for MOC devices of the connected MOC local network. This includes support of management requests from NGN and local (to the MOC local network) firmware and software management.
+- 2) MOC devices are required to support software and firmware management.
+- 3) MOC gateways and MOC devices are required to support configuration management.
+- 4) MOC gateways are required to support fault and performance data collection and storage.
+
+- 5) MOC devices are recommended to support fault and performance data collection and storage.
+
+### **10.6 Device addressing and identification**
+
+Based on the requirements in clauses 8.10 and 8.12, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC gateways are required to support mapping between the identification of an MOC device and one or more MOC local network addresses.
+- 2) MOC gateways are required to support mapping between the identification of an MOC device group and one or more MOC local network addresses for each MOC device within the group.
+- 3) MOC devices are required to support unique identification within the context of a single MOC application.
+- 4) An MOC gateway can optionally use temporary identifiers for MOC devices connecting and disconnecting to the network dynamically.
+- 5) An MOC gateway can optionally re-assign dynamically released temporary identifiers to other MOC devices.
+
+### **10.7 Security**
+
+Based on the requirements in clause 8.14, the following requirements apply to the MOC gateway and MOC device's capabilities:
+
+- 1) MOC gateways are required to identify and authenticate MOC applications, other MOC devices and MOC end users.
+- 2) MOC gateways are required to support mechanisms for secure transport, such as encryption and integrity protection.
+- 3) MOC devices are recommended to identify and authenticate MOC applications, other MOC devices and MOC end users.
+- 4) MOC devices are recommended to support mechanisms for secure transport, such as encryption and integrity protection.
+
+### **10.8 Accounting and charging**
+
+Based on the requirements in clause 8.8, the following requirements apply to the MOC gateway capabilities:
+
+- 1) MOC gateways are recommended to support different accounting and charging methods for the connected MOC devices.
+
+### **10.9 Data identification**
+
+Based on the requirements of collected data differentiation and related data handling in clause 8.17, the following requirements apply to the MOC device and MOC gateway's capabilities:
+
+- 1) MOC gateways are recommended to make data identifiable according to relevant policies.
+- 2) MOC devices can optionally make data identifiable according to relevant policies.
+
+# **11 Reference framework for MOC capabilities**
+
+### **11.1 High-level view**
+
+Figure 11-1 provides a high-level view of the reference framework for MOC capabilities.
+
+
+
+The diagram illustrates the high-level view of the reference framework for MOC capabilities. It is divided into three main domains: **MOC service domain**, **MOC device domain**, and **NGN domain**.
+
+- MOC service domain**: Contains **MOC applications**.
+- MOC device domain**: Contains **MOC devices** (with **MOC applications** and **Proprietary device**) and **MOC gateways** (with **MOC applications** and **MOC capabilities**).
+- NGN domain**: Contains **NGN capabilities** and **NGN**.
+
+Interfaces between domains:
+
+- ANI (Application to Network Interface)**: Connects **MOC applications** in the MOC service domain to **MOC capabilities** in the NGN domain.
+- UNI (User to Network Interface)**: Connects **MOC devices** and **MOC gateways** in the MOC device domain to **NGN capabilities** in the NGN domain.
+- NNI (Network to Network Interface)**: Connects **MOC capabilities** in the NGN domain to **MOC capabilities of other networks (e.g., Internet)**.
+
+Y.2061(12)\_F11-1
+
+Figure 11-1: High-level view of the reference framework for MOC capabilities. The diagram shows three main domains: MOC service domain, MOC device domain, and NGN domain. The MOC service domain contains MOC applications. The MOC device domain contains MOC devices (with MOC applications and Proprietary device) and MOC gateways (with MOC applications and MOC capabilities). The NGN domain contains NGN capabilities and NGN. Interfaces include ANI (Application to Network Interface) between MOC applications and MOC capabilities, UNI (User to Network Interface) between MOC devices/gateways and NGN capabilities, and NNI (Network to Network Interface) between MOC capabilities and other networks (e.g., Internet).
+
+**Figure 11-1 – High-level view of the reference framework for MOC capabilities**
+
+The MOC device domain is composed of MOC devices, proprietary devices and MOC gateways. MOC capabilities of the MOC device domain collaborate with MOC capabilities and NGN capabilities of the NGN domain to support MOC applications.
+
+The interface between MOC devices or gateways and the NGN is the user to network interface (UNI).
+
+The interface between MOC capabilities and MOC applications residing in the MOC device domain is the application to capability interface (ACI).
+
+The NGN domain is composed of:
+
+- NGN capabilities (modified and extended as necessary for the support of MOC applications as per clause 9);
+- MOC capabilities.
+
+The interface between the NGN and other networks is the network to network interface (NNI).
+
+The MOC service domain is composed of MOC applications.
+
+The interface between the NGN and MOC applications residing in the MOC service domain is the application to network interface (ANI).
+
+In order to support MOC applications, service interfaces are provided across ACI, ANI, NNI and UNI. The requirements of these service interfaces are given in clause 11.4.
+
+## 11.2 MOC capabilities in the NGN domain
+
+The main MOC capabilities in the NGN domain are shown in Figure 11-2. These capabilities provide standard interfaces for MOC applications to MOC devices and gateway for data collection, management and operations.
+
+The MOC capabilities shown in Figure 11-2 are [ITU-T Y.2240] capabilities adapted as necessary to the context of MOC.
+
+In line with [ITU-T Y.2240], the MOC capabilities also interact with NGN capabilities [ITU-T Y.2201], IT capabilities or Internet capabilities.
+
+NOTE 1 – The MOC capabilities in the NGN domain are positioned inside the NGN service stratum [ITU-T Y.2012].
+
+NOTE 2 – Other [ITU-T Y.2240] capabilities are not precluded to be part of, or adapted as, MOC capabilities in the NGN domain as shown in Figure 11-2.
+
+
+
+The diagram illustrates the MOC capabilities in the NGN domain. It consists of a large light blue rectangular container. Inside this container, there are nine smaller rectangular boxes arranged in a grid-like fashion. The boxes are labeled as follows: 'Accounting and charging' (top left), 'Access control' (top right), 'Service dispatcher' (second row left), 'Content management' (second row right), 'Application provisioning' (third row left), 'Context management' (third row right), 'MOC resource registry' (fourth row left), 'MOC resource repository' (fourth row right), and 'MOC resource manager' (bottom left, spanning the width of two boxes).
+
+Diagram showing MOC capabilities in the NGN domain. A large light blue rectangle contains several smaller boxes representing different capabilities: Accounting and charging, Access control, Service dispatcher, Content management, Application provisioning, Context management, MOC resource registry, MOC resource repository, and MOC resource manager.
+
+**Figure 11-2 – MOC capabilities in the NGN domain**
+
+#### **11.2.1 Accounting and charging**
+
+This capability supports accounting and charging modes and mechanisms for MOC applications, including:
+
+- support of revenue sharing among the various actors involved in the MOC ecosystem
+- support of event-based online or offline charging in the MOC ecosystem.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.2 Access control**
+
+This capability performs authentication and authorization of MOC applications before allowing them to access a specific set of capabilities. The access control capability provides translation of application programming interfaces (APIs) and protocols across different service interfaces as well as access from applications to functionalities exposed by MOC capabilities.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.3 Service dispatcher**
+
+This capability provides unified message routing and message exchange mechanisms among the MOC capabilities in the NGN domain.
+
+The service dispatcher also provides API and protocol transformation from MOC applications to common message structure and business event handling and vice versa.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.4 Content management**
+
+Content can be provided as resources to an MOC application or end users by different MOC device providers (e.g., content providers and end users).
+
+The content management capability provides the extraction of appropriate information (including size, type, location) from content, enabling the MOC capabilities in the NGN domain to ensure the integrity of the content itself.
+
+The content management capability provides profiling of content as appropriate to enable its delivery to different MOC applications, such as content for specific MOC applications or content for a specific MOC end user.
+
+The content management capability provides dispatching of content in order to expose content to applications.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.5 Application provisioning**
+
+This capability is used for the deployment of applications in a secure way by the MOC application provider when applications are available for deployment. This capability provides application packaging, publishing, deployment, lifecycle management and monitoring functions.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.6 Context management**
+
+This capability collects, aggregates and manages context information related to different context sources, exposing context information, including to other MOC capabilities, according to the MOC application provider's policies.
+
+For further details on this capability see [ITU-T Y.2240].
+
+#### **11.2.7 MOC resource registry**
+
+This capability provides the functionalities related to the registration, de-registration, discovery and governance of resources offered by MOC device providers. Registration-oriented resource descriptions including unique resource identification and resource addressing are published in the MOC resource registry.
+
+This capability defines a mechanism for a resource of an MOC device provider to be registered within the MOC capabilities in the NGN domain, so that this resource can be located and accessed by applications.
+
+This capability corresponds functionally to the resource registry capability in [ITU-T Y.2240] when adapted to the context of MOC.
+
+#### **11.2.8 MOC resource repository**
+
+This capability provides functionalities for the storage of information related to the registered MOC resources. Being stored in the MOC resource repository, the MOC resource information can be accessed by the authenticated and authorized MOC applications. Information related to the registered resources includes various suitable packaging tools for application developers.
+
+This capability corresponds functionally to the resource registry capability in [ITU-T Y.2240] when adapted to the context of MOC.
+
+#### **11.2.9 MOC resource manager**
+
+This capability performs the control functions for resources provided by NGN and MOC devices in order to satisfy the MOC applications' requirements, including the management of the dynamic information concerning the reachability status of MOC devices (e.g., online/offline, forwarding information).
+
+This capability corresponds functionally to the resource registry capability in [ITU-T Y.2240] when adapted to the context of MOC.
+
+### 11.3 MOC capabilities in the MOC device domain
+
+The MOC capabilities in the MOC device domain are shown in Figure 11-3.
+
+
+
+The diagram shows a large light blue rectangle containing six smaller, light blue rectangular boxes arranged in a 3x2 grid. The boxes are labeled as follows:
+
+- Top-left: MOC resource Repository
+- Top-right: Security
+- Middle-left: Remote management
+- Middle-right: Communication aggregator
+- Bottom-left: MOC application enabler
+- Bottom-right: Communication
+
+Figure 11-3: MOC capabilities in the MOC device domain. A diagram showing six capabilities arranged in a 3x2 grid within a larger container.
+
+**Figure 11-3 – MOC capabilities in the MOC device domain**
+
+#### 11.3.1 Communication aggregator
+
+This capability, residing in MOC gateways, performs proxy and traffic aggregator functions.
+
+Based on the requirements identified in clause 10.3, the communication aggregator capability supports the relaying of traffic between MOC devices and NGNs, QoS mechanisms based on the MOC application policy and the recording of charging information for MOC devices within the MOC local network.
+
+#### 11.3.2 MOC application enabler
+
+Based on the requirements identified in clause 10.1, this capability performs the exposure to MOC applications of MOC capabilities residing in the MOC gateway and MOC devices.
+
+#### 11.3.3 MOC resource repository
+
+Based on the requirements identified in clause 10.1, this capability, residing in MOC gateways, provides functionalities for the storage of information related to the registered MOC devices. Being stored in the MOC device repository, the MOC devices' data can be read by the authenticated and authorized MOC applications.
+
+### 11.3.4 Remote management
+
+Based on the requirements identified in clause 10.5, this capability supports configuration management, fault management, performance management, software and firmware upgrade of the MOC gateway and MOC devices in the MOC local network.
+
+NOTE – The functions above can also be realized by local management capabilities of the MOC devices and gateway.
+
+#### 11.3.5 Security
+
+Based on the requirements identified in clause 10.7, this capability performs registration and mutual authentication with MOC applications.
+
+The security capability provides encryption and integrity protection on data exchanged with the NGN and MOC applications to ensure secure delivery.
+
+The security capability performs key management based on the service keys generated in MOC devices, and protects from unauthorized applications' access to MOC devices.
+
+#### **11.3.6 Communication**
+
+Based on the requirements identified in clauses 10.3, 10.6, 10.8 and 10.9, this capability performs the generic communication functions in the MOC devices and gateway.
+
+The communication capability provides application data transport functions, delivers and receives data to/from MOC applications in accordance with the service criteria (e.g., daily network traffic load, MOC device location, access time schedules and durations), and handles these data.
+
+### **11.4 MOC service interfaces**
+
+The MOC service interfaces support:
+
+- MOC applications hosted in MOC devices and gateways, which access NGNs via UNI;
+- MOC applications hosted in MOC devices and gateways, which access the MOC capabilities hosted in the MOC gateway via ACI;
+- MOC applications hosted in MOC devices, which access the MOC capabilities hosted in those same MOC devices via ACI;
+- MOC applications hosted in the MOC service domain, which access the NGN via ANI.
+- MOC applications hosted in the MOC service domain, which access the MOC capabilities of other networks via NNI.
+
+MOC applications hosted in MOC devices and gateways can be invoked by an MOC end user and other MOC applications, e.g., MOC applications hosted in the MOC service domain.
+
+MOC service interfaces are recommended to implement standardized APIs, protocols and technologies to realize the service exposure towards MOC applications.
+
+### **11.4.1 Service interface requirements across ACI**
+
+The service interface across the ACI is used to provide interaction in the MOC device domain between the MOC capabilities of devices and gateways and MOC applications of devices and gateways. The service interface across the ACI allows an application residing in an MOC device to access MOC capabilities in the same MOC device or in an MOC gateway. It also allows an application residing in an MOC gateway to access MOC capabilities in the same MOC gateway.
+
+The ACI is required to enable the following functions:
+
+- registration of the MOC devices and gateway to the MOC capabilities in the MOC device and gateway (e.g., registration of a sensor or GPS in a car to the gateway in the car);
+- MOC applications' execution requests of an MOC device-specific tasks by an MOC device and gateway or group of MOC devices and gateways;
+- subscription and notification to specific events (e.g., mutual subscription and notification to specific events (e.g., connectivity of the MOC devices and gateway) between MOC capabilities and applications);
+- the MOC devices and gateway's requests of group creation, deletion and members' listing.
+
+### **11.4.2 Service interface requirements across UNI**
+
+The service interface across the UNI is used to provide interaction between the MOC capabilities of MOC devices and gateways and the MOC capabilities of the NGN. The UNI is recommended to support standardized APIs for exposing resources provided by the MOC device domain to the MOC capabilities in the NGN domain.
+
+The UNI is required to enable the following functions:
+
+- registration of MOC capabilities in the MOC device domain to the MOC capabilities in the NGN domain;
+
+- request from MOC devices of the execution of a specific task to be performed by an MOC application;
+- subscription and notification of specific events from/to the MOC device domain;
+- requests of group creation, deletion and members' listing.
+
+### **11.4.3 Service interface requirements across ANI**
+
+The service requests initiated by MOC applications are sent to the MOC capabilities in the NGN domain via the ANI. The service interface across the ANI is required to provide the interaction between MOC applications in the MOC service domain and MOC capabilities in the NGN domain.
+
+The ANI is recommended to support standardized APIs for exposing resources provided by the NGN domain to MOC applications.
+
+The ANI is required to enable the following functions:
+
+- registration of MOC applications to the MOC capabilities in the NGN domain;
+- request from MOC applications of the execution of a specific task to be performed by an MOC device and gateway or group of MOC devices and gateways;
+- subscription and notification of specific events from/to MOC applications;
+- requests of group creation, deletion and members' listing.
+
+### **11.4.4 Service interface requirements across NNI**
+
+The service interface across the NNI is used to provide interaction with MOC capabilities of other networks. The following service interface across the NNI is relevant for the interaction of NGNs with MOC capabilities of other networks:
+
+- service interface between NGNs and other networks (NGNs or non-NGNs), both of which have capabilities for supporting MOC applications.
+
+NOTE – The scenario of NNI interaction between an NGN and other networks which have no capabilities for the support of MOC applications is not relevant as it implies only transport level interaction.
+
+# **12 Security considerations**
+
+Security requirements for MOC applications are described in clause 8.14.
+
+Security requirements for the NGN domain are provided in clause 9.2.5.
+
+Security requirements for the MOC device domain are provided in clause 10.7.
+
+# Appendix I
+
+## Actors and related roles in the MOC ecosystem
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The following items identify different actors of the MOC ecosystem and the business roles (see clause 6.3) that they can play:
+
+- **The "carrier" actor.** The "carrier" actor plays the role of network provider. Depending on the business scenario, the "carrier" actor may also play the role of MOC application provider, MOC platform provider and MOC device provider.
+- **The "third party application provider" actor.** The "third party application provider" actor plays the role of MOC application provider. Examples of third party application providers include web-based application providers. The "third party application provider" actor may also play (but is not limited to) the role of MOC platform provider.
+- **The "third party device provider" actor.** The "third party device provider" actor plays the role of MOC device provider. Examples of third party device providers include device operators, end users. The "third party device provider" actor may also play (but is not limited to) the roles of MOC platform provider, MOC application provider and MOC application customer.
+
+## Appendix II
+
+## MOC use cases
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### II.1 e-Health
+
+e-Health is a relatively recent term used to designate healthcare practices supported by electronic processes and communications.
+
+Figure II.1 shows an example of e-Health service configuration.
+
+
+
+The diagram illustrates an e-Health service configuration. At the top, an 'e-Health centre' (represented by a server icon) and a 'Hospital' (represented by a building icon with a red cross) are connected to a central cloud labeled 'NGN' (Next Generation Network). A 'Doctor' (represented by a person icon) is also connected to the Hospital. Below the NGN cloud, a 'Gateway' is shown. A house represents the patient's home. Inside the house, a 'Heartbeat sensor on patient' is shown. A 'Camera' is also shown inside the house. The house is connected to the Gateway, which in turn connects to the NGN cloud. The label 'Y.2061(12)\_FII.1' is located at the bottom right of the diagram.
+
+Diagram of e-Health service configuration showing a patient's home connected to an e-Health centre, hospital, and doctor via a Next Generation Network (NGN).
+
+**Figure II.1 – e-Health service configuration**
+
+Various types of devices are involved in the provisioning of e-Health services. Some of these devices only collect data and interact with the network (e.g., heartbeat sensors), others can interact bidirectionally (e.g., cameras), some devices usually generate small amounts of data (e.g., thermometers), while others may deal with multimedia streaming (e.g., cameras) or, deal with call session control (e.g., SIP terminals supporting video calls). Some devices may even work as both gateway and sensor-like service platforms.
+
+The e-Health devices gather data and send them to the relevant parties, such as the e-Health centre in Figure II.1. Hospitals, doctors and families can subscribe to the service to get raw or processed data.
+
+The devices associated with patients can access the network directly or via a gateway(s) (e.g., home gateway or a gateway worn on the body):
+
+- 1) When the patients stay in an indoor environment, the devices can access the network via a single static home gateway or via multiple dynamic home gateways (in this second case the patients can move and access the network via different gateways).
+- 2) When the patients are outdoors, the devices can access the network directly via a mobile network or indirectly via the gateway worn on the body.
+
+The following technical challenges need to be considered for e-Health:
+
+- Grouping should be supported. This is useful, for instance, for multiple patients with the same type of disease, or in the case of a single patient, to manage a set of devices which can be managed in group mode.
+
+- Optimized traffic control should be supported. For example, the detected data may be very small and need to be reported to the network every hour: in such a case, it is a waste of resources to be permanently connected to the network. The network should be optimized in terms of traffic control, and, in such a case, traffic could be delivered, for example via user plane signalling without a data-dedicated IP bearer. Additionally, devices on a patient might stay in sleep mode and wake up when the doctor needs to diagnose the patient remotely.
+- Different mobility levels should be supported. For instance, in the case of patients with poor mobility (moving infrequently and not very far), it is a waste of resources to activate full mobility management capabilities.
+- Remote device activation and management should be supported. For example, devices in sleep mode would be woken up only when the doctor needs to diagnose the patient remotely.
+- Time control should be supported. For instance, devices on patients may collect a lot of data but do not always need to report them at every collection as the data may be not very critical, e.g., only for routine examination. In these scenarios, the network can allocate specific time slots for the devices' data to be reported (the devices cannot report data during other time periods or are charged at higher rates in those periods).
+- Device profiles should be supported. Patient may buy new devices and connect them to the network dynamically: device related information should be included in the device profile and be updated dynamically to enable the network authentication and control of the newly-added devices and also their removal.
+- Devices behind a gateway should be able to be identified by the network. The gateway might provide only a bearer channel and act as a data aggregator for the devices connected to it or might provide service control for the devices connected to it. In the first case, the devices connected to the gateway should be controlled by the network, or by both the network and gateway.
+- Proprietary devices should be supported. There are plenty of proprietary devices and gateways running in networks: adaptation to existing proprietary devices and gateways should be supported.
+- Service profile should be supported. Patients are usually not very familiar with the services offered by different hospitals, they can usually just logon to the e-Health centre's portal and access services, whereas the e-Health centre is usually familiar and can determine the target hospitals based on their professional knowledge. There might be one or multiple hospitals providing medical services to a patient jointly. In other words, when the devices on a patient report data to the e-Health centre, the centre can intelligently help the patient to select the best target hospitals and route the data to those hospitals for joint diagnosis. Multimedia call control sessions might be needed in this scenario, including audio, video, text messaging, etc. The devices should also interact with multiple applications.
+
+When doctors diagnose and provide healthcare services remotely, they usually also need the existing internal disease diagnostics system or database system of the hospital for assistance: data reported from devices may be input to the existing hospital internal system. In this case, the devices should be interoperable with existing systems (e.g., data format, service capabilities invocation, etc.), that is the e-Health system should be able to collaborate and inter-work with the existing application systems which are usually heterogeneous.
+
+- Traffic load balancing should be taken into consideration in order to cope with particular situations. For instance, due to the number of patients in areas varying quite considerably, there may be relatively high rates of patients in geriatric wards, communities of elderly people and certain cities, as compared with other cities. The network should be able to handle accordingly the system imbalance in case of specific situations of high traffic or
+
+service load, especially for video-like services (for example, when a lot of patients use remote video diagnosis).
+
+### II.2 Tsunami warning service
+
+The tsunami warning system is used to detect tsunamis and issue warnings to prevent loss of life and property.
+
+
+
+The diagram illustrates the configuration of a tsunami warning service. At the bottom, three sensors are positioned along a coastline, each labeled 'Sensor'. These sensors are connected to a central cloud labeled 'NGN' (Next-Generation Network). Above the NGN cloud is a 'Warning system' represented by a server icon. Three arrows originate from the Warning system, pointing to different communication methods: 'Broadcast system' (leading to a television), 'Instant message' (leading to a person at a computer), and 'Short message' (leading to a mobile phone). The background of the lower part of the diagram shows a coastal landscape with mountains and water.
+
+Y.2061(12)\_FII.2
+
+Diagram of Tsunami warning service configuration showing sensors connected to an NGN cloud, which then connects to a warning system and various communication channels.
+
+**Figure II.2 – Tsunami warning service configuration**
+
+As shown in Figure II.2, it consists of two equally important components: a network of sensors to detect tsunamis and a communications infrastructure to issue timely alarms to help evacuation of coastal areas. Detection and prediction of tsunamis is only half the work of the system. The other equal importance is the ability to warn the populations of the areas that will be affected. To save lives more certainly, proper guidance for escape according to their situation in danger (e.g., time, place, and occasion) should be considered. For a visitor who comes to an unfamiliar area at night, a simple alarm is not enough to escape to a safe place. All tsunami warning systems feature multiple lines of communications (such as SMS, e-mail, fax, radio, text and telex, often using hardened dedicated systems) enabling emergency messages to be sent to the emergency services and armed forces, as well to population alerting systems (e.g., sirens). In this use case, the service is required to support:
+
+- inter-working with heterogeneous network, including: mass media networks (e.g., radio network, television network) and dedicated communication systems (e.g., sirens);
+- delivery of emergency information, including both the primary information generated by the detector and the secondary information transferred to the target population;
+- delivery of emergency information over multiple networks, including reliable and unreliable bearers (e.g., communication through satellite systems) to maximize the probability of the delivery;
+
+NOTE – Information integrity which might be compromised by reliable and unreliable bearers needs further study.
+
+- system robustness, i.e., the system should support information bursting within a short while due to a large number of machines (e.g., emergency detectors or sensors) within an area;
+- prioritized delivery of emergency information, i.e., emergency message for an earthquake, should be prioritized compared with other service messages.
+
+### II.3 Motorcade management
+
+Figure II.3 shows a typical service configuration for motorcade management.
+
+
+
+The diagram illustrates a motorcade management service configuration. At the top, a 'Control centre' (represented by a computer monitor and keyboard) is connected to a cloud labeled 'NGN'. The 'NGN' cloud is connected to a bus labeled 'Gateway'. The bus is equipped with a 'Sensor', 'GPS', and 'Camera'. The bus is labeled 'Y.2061(12)\_FII.3'.
+
+Diagram of a typical motorcade management service configuration. A control centre at the top is connected to a cloud labeled NGN. The cloud is connected to a bus labeled Gateway. The bus is equipped with a Sensor, GPS, and Camera. The bus is labeled Y.2061(12)\_FII.3.
+
+**Figure II.3 – Typical motorcade management service configuration**
+
+Every bus is equipped with devices and gateways which have the same characteristics. The control centre gathers data related to location, speed and the situation given from the sensors, global positioning system (GPS) terminal and cameras of the bus. Data aggregated through a gateway located on the bus are transmitted to the NGN using wireless access.
+
+The dynamic timetable can be forwarded to the monitor screen on the bus stop by the control centre according to the location information collected from the bus.
+
+When a sensor on the bus detects an abnormal situation, such as the smell of gasoline, an alarm indication is sent to the control centre.
+
+The bus always has a fixed route which means it should not move out of the pre-defined roads. When a bus moves out of a particular area, an application should be triggered. For example, a call may be made to the bus driver, or an alert indication may be made to the bus administrator while the bus moves out of the area.
+
+In this use case, the service is required to support:
+
+- location based service: an application should be triggered when devices are in or out of a particular area;
+- prioritized service level, for example, alarm indication should be prioritized compared with other data;
+- group management for devices with the same characteristics.
+
+### II.4 Smart home
+
+Smart home usually involves a mix of different devices and applications, such as real-time or near real-time sensors, power outage notification and power quality monitoring.
+
+Figure II.4 shows a typical "smart home" configuration.
+
+
+
+Diagram of a typical smart home service configuration. At the top, 'Smart home applications' (represented by server racks) connect to a cloud labeled 'NGN'. Below the cloud is a 'Gateway' device. The gateway connects to a house containing various smart home devices: 'Sensor', 'Camera', 'Breakers', 'Valves', 'Water meter', 'Gas meter', and 'Power meter'. A person named 'Tom' is shown on the right, holding a mobile phone, with arrows indicating communication between him and the NGN cloud and the Gateway.
+
+Y.2061(12)\_FII.4
+
+**Figure II.4 – Typical smart home service configuration**
+
+As shown in Figure II.4, a "smart home" scenario often refers to devices (e.g., smoke sensor, electricity meters, gas meters, etc.) which are connected to a smart home application platform via a gateway located in the smart home. The data centre collects data from the "smart home" devices and is able to control these devices remotely via the gateway. In this scenario, Tom's house information related to power, gas and water consumption can be collected and reported to the smart home applications platform. At the same time, Tom can manage the application related policy of his home using the smart home applications and the application related policy can be sent to MOC devices in order to be executed according to Tom's requirements.
+
+For example, Tom defines the application related policy as follows:
+
+- 1) If a fire sensor detects signs of a fire in Tom's house, then the fire sensor shall send a short message alarm to Tom's mobile phone.
+- 2) If an alarm is triggered by a door break-out sensor then a video communication is initiated allowing Tom to see in real time what is happening inside his house.
+
+Let us assume that a thief breaks open a door of Tom's house. When detecting this event, the MOC device (i.e., the door break-out sensor) initiates a video communication between Tom and a visual surveillance camera located in Tom's home. Tom watches and records the video on his mobile, (a record which may be used as evidence of the crime).
+
+Let us now consider that Tom is out of his house while a fire occurs in his kitchen where his son is cooking. When detecting this event, the MOC device (i.e., the smoke sensor) sends an alarm message to Tom directly. Upon receipt of this information, Tom initiates a video communication with the camera to check the status of the kitchen, and to tell his son how to use the fire extinguisher or to exit. For privacy and security reasons, the camera is only connected and controlled by members of Tom's family.
+
+In this use case, the service is required to support:
+
+- enhanced video/audio based capabilities, such as concurrent video streaming and local-breakout;
+- group management for MOC devices with the same characteristics, for example, power meters in different smart homes;
+- message broadcasting and multicasting based on specific characteristics, such as group and location, to support functions such as firmware upgrading.
+
+## II.5 Integration with Internet services
+
+There are many attractive services emerging on the Internet, such as social network services (SNS). MOC applications should be able to work with those Internet services to ensure that customers can use the MOC applications with existing popular Internet services. Integrated with Internet services, MOC applications themselves will extend their value chains and attract more customers.
+
+In some integration scenarios, MOC capabilities should be able to apply data detection rules (i.e., setting rules) to the MOC devices and gateway. Once detected, the data should be transferred to the MOC capability in a defined format. The formatted data facilitates the MOC capability to communicate smoothly with the Internet services that provide publishing services.
+
+Figure II.5 shows an example use case of the integration of MOC application and Internet service.
+
+
+
+Intelligence transportation applications
+
+SNS
+
+NGN
+
+Camera
+
+Internet
+
+Tom
+
+Y.2061(12)\_F11.5
+
+Figure II.5: Typical internet service configuration. The diagram illustrates the integration of MOC applications with Internet services. On the left, 'Intelligence transportation applications' (represented by a control room image) connect to an 'NGN' (Next-Generation Network) cloud. The NGN cloud is connected to two 'Camera' icons, which in turn connect to a night-time street traffic image. On the right, 'SNS' (Social Network Services) servers (represented by server rack icons) connect to an 'Internet' cloud. The Internet cloud is connected to a user icon labeled 'Tom'. A horizontal line connects the SNS servers to the Intelligence transportation applications, indicating data flow. The diagram is labeled 'Y.2061(12)\_F11.5' at the bottom right.
+
+**Figure II.5 – Typical internet service configuration**
+
+AN MOC application provider offers intelligence transportation service for customers. The service allows the customers to access their interested content via SNS with their preferred rules (e.g., publishing times). The provider collects the content by an MOC application and provides it for the customers via SNS according to the customers' rules.
+
+Tom finds that the intelligence transportation service provides real time pictures and videos of city traffic captured by the cameras on the streets and that information is provided via SNS. Tom subscribes to this service (e.g., regularly updated every five minutes) and receives the instantaneous traffic information on his SNS.
+
+The service updates the information via SNS according to Tom's preference. Tom can find out the highway traffic information on his way home.
+
+In this use case, the service is required to support:
+
+- integration with Internet services using the MOC capabilities;
+- setting rules to detect the MOC devices and gateway's data and transfer the data with a defined format to the capability which is used to communicate with the Internet services for publishing;
+- enabling customers to access relevant MOC content via the Internet services with defined rules;
+- detecting the relevant MOC content and provide it to the Internet services based on the rules;
+- communicating with the Internet services to exchange the information.
+
+## Bibliography
+
+- [b-ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN*.
+- [b-ITU-T Y.2011] Recommendation ITU-T Y.2011 (2004), *General principles and general reference model for Next Generation Networks*.
+- [b-ITU-T Y.2213] Recommendation ITU-T Y.2213 (2008), *NGN service requirements and capabilities for network aspects of applications and services using tag-based identification*.
+- [b-ITU-T Y-Sup.7] ITU-T Y-series Recommendations – Supplement 7 (2008), *Supplement on NGN release 2 scope*.
+- [b-ITU-T Q.1741.7] Recommendation ITU-T Q.1741.7 (2011), *IMT-2000 references to Release 9 of GSM-evolved UMTS core network*.
+- [b-ETSI TS 102 689] ETSI TS 102 689 V1.1.1 (2010), *Machine-to-Machine communications (M2M); M2M service requirements*.
+- [b-ETSI TS 102 690] ETSI TS 102 690 V1.1.1 (2011) *Machine-to-Machine communications (M2M); Functional architecture*.
+- [b-3GPP TS 22.368] 3GPP TS 22.368 V 11.3.0 (2011), *Service requirements for Machine-Type Communications (MTC)*.
+- [b-3GPP2-S.R0141-0] 3GPP2 S.R0141-0 V.1.0 (2010), *Study for Machine-to-Machine (M2M) Communication for cdma2000 Networks*.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7f9d1c6f40e7583c3f53c92c02eeceb4d655937f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a06aa91b51b92f2fc770fe7a79eb07f9712aa1f3fb3dc6812c65d2bc1842ec49
+size 107636
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/5132b3a97ac70fe4765c1e07e66b72b3_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/5132b3a97ac70fe4765c1e07e66b72b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0caa5cc00ab1641dfc5c6cdd4834d0c6c8339b61
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/5132b3a97ac70fe4765c1e07e66b72b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e6726198e8aad6ba9cb336fb8ebc71e96a1283ace9afb976162b421b339e9a55
+size 121743
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/75e4b78ee25f885d73120e3066a5253e_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/75e4b78ee25f885d73120e3066a5253e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..90665245d8dd90e9d516728d7a667ca7b62f44a0
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/75e4b78ee25f885d73120e3066a5253e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bbab7ceb1f853274a88b14cc442b42b0d6443e453e2f0643e4f0209f311ffe81
+size 78406
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7b1417bd08e9c8a262c90810ce54c457b7d167a9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b4a428fae567543183c69d2c9f497888fef8929d53654dac4ead464f32a0086b
+size 131180
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/9ae17964ddd9b814c7d905b1af2fddf2_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/9ae17964ddd9b814c7d905b1af2fddf2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b207b3454e1b759b7f379dad361cbd95079863db
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/9ae17964ddd9b814c7d905b1af2fddf2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0735b359974cff8283e836afdacad009fcdd9858ce502df3acf48e2fb9fdb7d5
+size 100989
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6bfa2f386480d74a9aa9a2b242d1d49a9eb96087
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0eb3bbdfaea89e7c79add596be6f5a637aa5b2b255307feedaa64373d18d0bfd
+size 67215
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4859bc6616964fa211000e410ab01cd505ecc58a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4cf8c3a8bfc5eab5843e558697ed4622b911be1b53a9ec9d765bd20d35d77f54
+size 24828
diff --git a/marked/Y/T-REC-Y.2072-201805-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..bf1b308de680c09aa2452d911341281917dca5f7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2072-201805-I_PDF-E/raw.md
@@ -0,0 +1,1021 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2072
+
+(05/2018)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Next Generation Networks – Frameworks and functional
+architecture models
+
+# --- **Framework for an energy-sharing and trading platform**
+
+Recommendation ITU-T Y.2072
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|-----------------|---------------|
+| CLOUD COMPUTING | Y.3000–Y.3499 |
+|-----------------|---------------|
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.2072
+
+# Framework for an energy-sharing and trading platform
+
+## Summary
+
+To increase the efficiency of the electricity grid and reduce electricity grid wastage, it is important to support an open service platform with the capacity for more effective electricity markets and electricity trading. Thus, Recommendation ITU-T Y.2072 provides a framework for an energy-sharing and trading platform for integrated control and management, taking into account energy production, storage and consumption. After identifying key characteristics and core technologies of the platform, Recommendation ITU-T Y.2072 specifies requirements taking into account the energy value chain made up of various stakeholders. Then, Recommendation ITU-T Y.2072 provides an architectural overview specifying related interfaces and functional blocks. Finally, mechanisms for energy information exchange to support integrated control and management services on the energy-sharing and trading platform are described.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.2072 | 2018-05-29 | 13 | 11.1002/1000/13614 |
+
+## Keywords
+
+distributed energy resources, energy platform, energy market, energy sharing, energy trading.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2018
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|---------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | Introduction to an energy-sharing and trading platform..... | 3 |
+| | 6.1 The concept of an energy-sharing and trading platform ..... | 3 |
+| | 6.2 The service concept in the energy market ..... | 4 |
+| 7 | Requirements for an energy-sharing and trading platform..... | 6 |
+| | 7.1 Customer domain..... | 6 |
+| | 7.2 Distribution domain..... | 7 |
+| | 7.3 Operation domain ..... | 7 |
+| | 7.4 Service provider domain..... | 7 |
+| | 7.5 Markets domain ..... | 7 |
+| 8 | Architecture overview of an energy-sharing and trading platform ..... | 7 |
+| | 8.1 Generic architectural model of an energy-sharing and trading platform ..... | 7 |
+| | 8.2 Functional architecture for an energy-sharing and trading platform..... | 11 |
+| 9 | Mechanisms for energy information exchange..... | 15 |
+| | 9.1 Communication protocol adaptation ..... | 15 |
+| | 9.2 Energy resource monitoring and measurement ..... | 16 |
+| | 9.3 Resource aggregation and control ..... | 16 |
+| | 9.4 Energy balancing and trading..... | 16 |
+| | 9.5 Data repository ..... | 17 |
+| 10 | Security considerations..... | 17 |
+| | Appendix I – A possible system model for an energy-sharing and trading platform ..... | 18 |
+| | I.1 ETS..... | 18 |
+| | I.2 ETC..... | 19 |
+| | I.3 EIMS..... | 19 |
+| | I.4 Energy-trading communication module..... | 19 |
+| | I.5 Energy information exchange protocols..... | 19 |
+| | Bibliography..... | 20 |
+
+
+
+# Recommendation ITU-T Y.2072
+
+# Framework for an energy-sharing and trading platform
+
+# 1 Scope
+
+To increase the efficiency of the electricity grid and reduce electricity grid wastage, it is important to support an open service platform with the capacity for more effective electricity markets and electricity trading. Thus, this Recommendation provides a framework for an energy-sharing and trading platform for integrated control and management taking into account energy production, storage and consumption.
+
+This Recommendation covers:
+
+- key characteristics and core technologies for an energy-sharing and trading platform;
+- requirements taking into account the energy value chain made up of various stakeholders;
+- architectural overview specifying related interfaces and functional blocks;
+- mechanisms for energy information exchange.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T X.1111] Recommendation ITU-T X.1111 (2007), *Framework of security technologies for home network*.
+- [ITU-T Y.2071] Recommendation ITU-T Y.2071 (2015), *Framework of a micro energy grid*.
+- [ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1*.
+
+# 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 aggregator:** A system in smart grid for collecting the energy generated by residences and micro grids.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.2 customer:** The end user of energy or services, who may also generate, store, and manage the energy.
+
+NOTE 1 – Based on [b-ITU-T Smart-O-30].
+
+NOTE 2 – Traditionally, three customer types are discussed, each with its own domain: residential, commercial, and industrial.
+
+**3.2.3 demand response (DR):** A smart grid feature that allows consumers to reduce or change their electrical use patterns during peak demand, usually in exchange for a financial incentive. Mechanisms and incentives for utilities, business, industrial, and residential customers to cut energy use during times of peak demand or when power reliability is at risk. Demand response is necessary for optimizing the balance of power supply and demand.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.4 distributed energy resource (DER):** An energy generation and energy storage facility located at the customer premises or power transmission and distribution systems.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.5 energy management system (EMS):** A computer system comprising a software platform providing basic support services and a set of applications providing the functionality needed for the effective operation of electrical generation and transmission facilities so as to ensure adequate security of energy supply at minimum cost.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.6 energy storage:** Energy storage provides storage functions of electricity using various types of batteries.
+
+NOTE 1 – Based on [b-ITU-T Smart-O-30].
+
+NOTE 2 – One example usage of energy storage is used to respond effectively to dynamic price mechanism from utility network. The electric energy is stored to the storage during lower price period relatively, while the stored electric energy may replace the higher price of electric power from utility network.
+
+**3.2.7 renewable energy certificate (REC):** A tradable, non-tangible energy commodity that represents proof that energy was generated from an eligible renewable energy resource (renewable electricity) and was fed into the shared system of power lines that transport energy.
+
+NOTE – An REC is also known as a “green tag”, “renewable energy credit”, “renewable electricity certificate”, or “tradable renewable certificate”.
+
+**3.2.8 service provider:** An organization providing services related to smart grid to electrical customers and utilities.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.9 substation:** A site where equipment for switching or regulating electrical voltage is located.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.10 supervisory control and data acquisition (SCADA):** A computer system that monitors an industrial, infrastructure, or facility-based control process.
+
+NOTE – Based on [b-ITU-T Smart-O-30].
+
+**3.2.11 utility provider:** An organization that provides electric power, gas, and water. In the smart grid, a utility provider supplies electric power.
+
+NOTE – Based on the definition of “utility company” in [b-ITU-T Smart-O-30].
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|-----------------------------------|
+| API | Application Programming Interface |
+| CBL | Customer Baseline Load |
+| DER | Distributed Energy Resource |
+| DNP | Distributed Network Protocol |
+| DR | Demand Response |
+
+| | |
+|---------|-------------------------------------------------------|
+| EI | Energy Interoperation |
+| EIMA | Energy-Integrated Management Application Service |
+| EIMC | Energy-Integrated Management Core Service |
+| EIMS | Energy-Integrated Management System |
+| EIPS | Energy Information Portal Service |
+| EMIX | Energy Market Information Exchange |
+| EMS | Energy Management System |
+| ESPS | Energy Service Provider Service |
+| ESS | Energy Storage System |
+| ESTS | Energy information Sharing and Trading Server Service |
+| ETC | Energy-Trading Client |
+| ETOS | Energy-Trading Operation Service |
+| ETS | Energy-Trading Server |
+| M2M | Machine to Machine |
+| OpenADR | Open Automated Demand Response |
+| REC | Renewable Energy Certificate |
+| SCADA | Supervisory Control And Data Acquisition |
+| SEP | Smart Energy Profile |
+| SOA | Service-Oriented Architecture |
+| VEN | Virtual End Node |
+| VTN | Virtual Top Node |
+| XML | Extensible Markup Language |
+
+# **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance.
+
+# **6 Introduction to an energy-sharing and trading platform**
+
+## **6.1 The concept of an energy-sharing and trading platform**
+
+As the smart grid shifts from the conceptual modelling phase to actual implementation, factors such as scalability, reliability and cyber security are becoming major issues. From the business perspective of the smart grid, it is also important to optimize energy supply and demand, as well as to stimulate the participation of energy-trading markets taking into account stakeholders such as wholesalers, retailers, third party service providers and consumers.
+
+For energy-related services in a smart grid environment in particular, taking into account energy production, storage and consumption, it is essential to build up an intelligent energy-sharing and trading platform for energy consumption recognition and prediction through context awareness from sensing information using machine to machine (M2M) communications, as well as for more efficient
+
+energy trading and delivery through DER clustering. The platform also has a significant role in market interoperability.
+
+Figure 6-1 is a conceptual diagram of an energy-sharing and trading platform for integrated control and management. The platform is interconnected with various entities for energy production, storage and consumption in a home or public building environment with DERs. The platform is responsible for exchanging price, balancing supply and demand, and congestion management with the sharing of energy information while delivering energy to consumers, guaranteeing security of supply at all times. An open platform with application programming interfaces (APIs) enables integrated control and management in the processes of production, storage and consumption, while offering reliable and high-quality services, and closely interworking among energy markets.
+
+
+
+Figure 6-1: A conceptual diagram of an energy-sharing and trading platform for integrated control and management. The diagram shows three main components: Energy consumption (top), Energy production (bottom left), and Energy storage (bottom right). In the center is the Energy sharing and trading platform (yellow oval). Arrows indicate the flow of information and energy between these components and the platform. From Energy consumption to the platform: Optimal load management, Settle Bill, Grid load information, Energy purchasing. From the platform to Energy consumption: Grid storage, Energy delivery. From Energy production to the platform: Production control, Settle Bill, Production info., Energy selling. From the platform to Energy production: Charge/discharge control, Settle Bill, Charge/discharge info., Energy selling. From Energy production to Energy storage: Grid production, Energy storage. A label 'Y.2072(18)\_F6-1' is at the bottom right.
+
+**Figure 6-1 – A conceptual diagram of an energy-sharing and trading platform for integrated control and management**
+
+An energy-sharing and trading platform needs the following key technologies:
+
+- M2M communications and big data analytics for energy control and operations in the integrated environment of various DERs [ITU-T Y.2071];
+- optimized charge and discharge operations of an energy storage system (ESS);
+- real-time price-based demand response (DR) control for energy assets, etc.
+
+To support the key technologies listed in the previous paragraph, the platform should be designed taking into account:
+
+- integrated control and management of energy production, storage and consumption for efficient energy-trading support with open services via APIs;
+- accurate data analytics and prediction based on sharing information;
+- energy-sharing networks and market operations;
+- optimized energy consumption according to various pricing schemes (e.g., real-time pricing and peak pricing);
+- interworking with various energy management systems (EMSs) and market interoperability.
+
+## 6.2 The service concept in the energy market
+
+This Recommendation considers a home or public building environment to provide an integrated energy management in the processes of energy production, storage and consumption. The energy-
+
+sharing and trading platform provides a solution to efficiently manage and supply energy through the sharing and trading of the saved energy in the energy market.
+
+#### **6.2.1 Basic processes in the energy market**
+
+The energy market business can be viewed as a set of processes. The following explains the main activities as basic processes for related use cases.
+
+- Plan: The messages defined in planning enable responsible parties for trade, production and consumption to send their schedules to system operators or the transmission capacity allocator in advance.
+- Trade: In trading, the responsible parties buy and sell energy to fulfil their contractual obligations through market operators.
+- Operate: Operations include message exchanges to handle the markets, e.g., a system operator orders up and down regulation to maintain balance in the system.
+- Measure: Measurement covers all stages from the collection of metered data until the settlement and reconciliation phase. After collection and distribution, metered data are validated, aggregated and distributed to relevant roles.
+- Settle: Settlement resolves imbalanced accounts of a market operator.
+- Bill: Billing includes all message exchanges with consumers and internal billing within the energy market.
+
+#### **6.2.2 Service scenario for energy-sharing and trading**
+
+This clause describes a service scenario for energy-sharing and trading as follows:
+
+- Stage 0: Energy market participation
+A customer (energy buyer or seller) can participate in the energy market through the relevant community in order to register energy resources and products that are pre-contracted in a home or public building.
+- Stage 1: Provision of the available energy to the community
+The attribute information (e.g., the energy type, energy availability) is managed through the registration of energy equipment (e.g., distributed resource, energy storage device in a home or public building) to the community. An individual community monitors the status of resources in real time to enable production and storage of energy.
+- Stage 2: Registration of energy assets in the energy market
+Energy production and storage devices pre-contracted to the community are registered as available energy assets in the energy market. After checking the energy type and energy serviceable level of the available registered energy assets in real time, the related energy information is updated to provide it to a customer.
+- Stage 3: Disclosure and bidding for energy products to support energy sharing and trading
+Information about available energy registered to multiple communities is disclosed, and the customer participates in energy price bidding for the amount and duration of energy required. If the request for the absolute duration of energy for use is not met depending on situations, the customer needs to negotiate the energy price according to the actual amount and duration of energy.
+- Stage 4: Establish contracts for the use of available energy
+The customer, for energy use scheduling, approves contracts for energy consumption in the energy market. Incentives and energy points are provided to the energy seller in the contract established. The energy buyer provides incentives to the energy seller and subtracts energy points.
+
+- Stage 5: Surplus energy trading
+Surplus energy information is disclosed to the energy market in direct transactions or the energy is sold back to the energy company to obtain credit in the form of backward meter counting. The credit can be replaced by energy points.
+
+# 7 Requirements for an energy-sharing and trading platform
+
+[b-NIST 1108] has specified a conceptual model of the smart grid, consisting of seven major functional areas called domains and the information flows between them, as well as the flow of electricity from power sources through transmission and distribution systems to customers. Table 7-1 gives a brief definition of these domains. For the entire market, bulk generation and transmission can be considered as a separate domain for the energy-sharing and trading platform. However, this Recommendation mainly focuses on an energy market platform for energy prosumers. Therefore, it defines functional requirements for the energy-sharing and trading platform from the remaining five domains, excluding bulk generation and transmission.
+
+**Table 7-1 – Domains and actors in the smart grid conceptual model**
+
+| Domain | Actors in the domain |
+|-------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Customers | End users of electricity. This domain may also store and manage the use of energy. Traditionally, there are three customer types, each with its own domain: residential, commercial and industrial. |
+| Markets | Operators and participants in electricity markets. |
+| Service providers | Organizations providing services to electrical customers and utilities. |
+| Operations | Managers of the movement of electricity. |
+| Bulk generation | Generators of electricity in bulk quantities. This domain may also store energy for later distribution. |
+| Transmission | Carriers of bulk electricity over long distances. This domain may also store and generate electricity. |
+| Distribution | Distributors of electricity to and from customers. This domain may also store and generate electricity. |
+
+## 7.1 Customer domain
+
+- The customer domain is required to monitor the safety status of the power generation facility and operate the generator according to the power generation schedule requested by the customer.
+- It is required to monitor the charge or discharge status of the energy storage device and control it according to charge/discharge schedule.
+- It is required to monitor the power consumption of energy overconsumption facilities and to control the operation mode of the load facilities in order to reduce the power peak load of the customer domain.
+- It is recommended to provide a function to analyse and predict the power consumption patterns of the customer domain and individual consumption devices to optimize energy consumption.
+- It is required to process DR events of the affiliated DR programme and provide the ability to integrate and control the energy generation and consumption resources within the domain to achieve the contracted load reduction capacity.
+- It is required to measure the generation capacity of individual generation facilities and energy storage devices within the management domain.
+
+## **7.2 Distribution domain**
+
+- The distribution domain is required to measure the amount of power flowing into or out of distribution lines connected to the management domain.
+
+NOTE – It is necessary to measure the total power consumption of the management domain and the generated power flowing into the grid.
+
+- It is recommended to collect the distribution status information from the monitoring and protection device of the distribution line and to provide the function to automatically control the distribution line in case of trouble.
+
+## **7.3 Operation domain**
+
+- The operation domain is required to periodically collect and store energy measurement data.
+- It is recommended to provide the ability to monitor and control the state of the power quality according to the terms of the contract.
+- It is required to provide the customer and service provider with the power measurement data and the status information of the distribution line when requested.
+
+## **7.4 Service provider domain**
+
+- The service provider domain is required to provide the ability to register as a resource to be managed after verifying that energy resources at the customer site are available for DR programmes and distributed resource trading.
+- It is required to provide the ability to collectively monitor and control grouped resources.
+- It is recommended to provide the function to predict the possible demand reduction and power generation capacity at the customer site.
+- It is required to support grouping of DR resources and small power generation resources at customer sites and engaging in energy transactions on behalf of customers.
+- It is required to notify the schedule information to the customers after generating the operation schedule of the small power generation resources according to the contract condition with the energy market.
+- It is required to receive events related to energy demand reduction and generation control from the energy market, and then notify the customer of the events online.
+
+## **7.5 Markets domain**
+
+- The markets domain is required to register and verify energy products consisting of customers' individual energy resources and their combination, and to enquire about details of energy products.
+- It is required to manage the processing of electronic bidding contracts between a seller and a buyer for registered energy products.
+- It is required to be interrogated and verified based on energy measurement data whether the traded energy product is generating or reducing demand by the contracted capacity.
+- It is required to settle the energy sales price considering incentives and penalties according to whether the contract conditions of the traded energy products are fulfilled.
+
+# **8 Architecture overview of an energy-sharing and trading platform**
+
+### **8.1 Generic architectural model of an energy-sharing and trading platform**
+
+To align with the domains and actors in the smart grid conceptual model listed in Table 7-1, Figure 8-1 shows the positioning of markets in relation to the seven domains, considering the energy-sharing and trading platform. Clauses 8.1.1 to 8.1.6 describe key features of each domain.
+
+
+
+The diagram illustrates a conceptual model for markets in a smart grid. At the center is an oval labeled "Energy sharing and trading platform". Surrounding this platform are six rectangular boxes, each representing a domain. Double-headed arrows connect each domain box to the central platform. The domains are:
+
+- Operation** (top-left): Distributed network operation: various SCADA, monitoring/control; General operation: asset management, meter data management.
+- Markets** (top-center, dashed box): Distributed energy resource aggregation, wholesaler and retailer marketing, dynamic pricing, trading, market management.
+- Service provider** (top-right): Customer management, billing/account management, home management, and building management.
+- Generation** (bottom-left): Bulk generation, control, traditional energy generation, and renewable energy storage.
+- Transmission and distribution** (bottom-center): Distributed energy generation (including wind, solar, thermal); Distributed storage, substation and local distribution network monitoring and control.
+- Customer** (bottom-right): Store, manage energy usage and generation (EMS); Home, building, industrial energy automation; metering, Load control/Demand Response.
+
+Y.2072(18)\_F8-1
+
+Figure 8-1: A conceptual model for markets in a smart grid. The diagram shows six domains arranged around a central 'Energy sharing and trading platform'. The domains are: Operation (top-left), Markets (top-center, dashed box), Service provider (top-right), Generation (bottom-left), Transmission and distribution (bottom-center), and Customer (bottom-right). Each domain is connected to the central platform by a double-headed arrow. The Markets domain is highlighted with a yellow background and a dashed border.
+
+**Figure 8-1 – A conceptual model for markets in a smart grid**
+
+#### 8.1.1 Markets
+
+- The main applications of the markets domain include DER aggregation, wholesaler and retailer marketing. Retailers sell power to customers and may play an aggregation role as a broker between customers and the market. Most retailers are connected to a trading organization to allow participation in the wholesale market.
+- Other applications include dynamic pricing, trading and market management. Traders are participants in markets and include aggregators for provision, consumption and curtailment, as well as other qualified parties.
+
+Markets are connected to three domains (namely generation, transmission and distribution, and customer) via the energy-sharing and trading platform. The interfaces between the markets domain and those domains containing generation are critical, because efficient matching of production with consumption relies on markets. Besides the generation domain, electricity generation also takes place in the transmission and distribution, and customer domains.
+
+In addition, the markets domain interacts with the operation and service provider domains.
+
+#### 8.1.2 Generation
+
+- The main applications in the generation domain include bulk generation plant control, measurement and traditional energy generation. Measurement is used to provide visibility to the flow of power and to indicate the condition of the systems in the field remotely.
+
+#### 8.1.3 Transmission and distribution
+
+- The main applications of the transmission and distribution domain include distributed energy generation, distributed storage, substation, and local distribution network monitoring and control. Substation management and control contains switching, protection and control equipment (e.g., substations connecting generation and storage with distribution).
+
+#### 8.1.4 Customer
+
+- The customer domain consists of several sub-domains (e.g., homes, commercial premises or public buildings and industrial premises). Hence, applications can be categorized into energy
+
+store, management and generation for homes, public buildings and industrial premises, respectively.
+
+#### 8.1.5 Operation
+
+- The operation domain consists of applications for distributed network operation, including supervisory control and data acquisition (SCADA) systems to monitor and control the status of devices in the bulk generation, transmission and distribution domains.
+- This domain also consists of applications for general operations, including asset management and meter data management (i.e., energy usage, energy generation, meter logs and meter test results) to make energy data available to authorized parties.
+
+#### 8.1.6 Service provider
+
+- The service provider domain consists of applications such as customer and account management and installation management. The aim of customer management is to manage customer relationships by providing point-of-contact and resolution for customer issues and problems. Conversely, the aim of installation management is to install and maintain the equipment on the premises that interacts with the smart grid.
+- This domain also consists of applications such as management of billing or accounts, homes and buildings.
+
+The conceptual model in Figure 8-1 consists of six domains for markets in a smart grid. For the entire market, the generation domain can be considered as a separate domain for the energy-sharing and trading platform. However, this Recommendation mainly focuses on the platform over the small distributed resource brokerage and the reduction of demand resources for energy prosumers. Therefore, it defines core systems, control equipment, generation and consumption sources, as well as energy measurement devices for the remaining five domains, excluding the generation domain as shown in Figure 8-2.
+
+
+
+```
+
+graph TD
+ subgraph Operation
+ O1[Utility grid and metre data mangement system]
+ end
+ subgraph Markets
+ M1[DR energy trading system]
+ M2[DER energy trading system]
+ M3[REC trading system]
+ end
+ subgraph Service_provider[Service provider]
+ SP1[DR management system]
+ SP2[DER management and operation system]
+ SP3[Integrated energy management system]
+ end
+ subgraph Distribution
+ D1[Utility grid electric power metre]
+ end
+ subgraph Customer
+ C1[Energy service gateway]
+ C2[Customer energy management system]
+ C3[DR/DER controller]
+ C4[Electric power generator and storage]
+ C5[Electric power load]
+ C6[Customer electric power metre]
+ end
+
+ E[Energy sharing and trading platform]
+ O1 <--> E
+ Markets <--> E
+ Service_provider <--> E
+ Distribution <--> E
+ Customer <--> E
+
+```
+
+Figure 8-2: Key system components of the energy-sharing and trading platform. The diagram shows a central 'Energy sharing and trading platform' (blue oval) connected to five domains: Operation, Markets, Service provider, Distribution, and Customer. The Markets domain is highlighted with a dashed border and contains three systems: DR energy trading system, DER energy trading system, and REC trading system. The Service provider domain contains three systems: DR management system, DER management and operation system, and Integrated energy management system. The Customer domain contains six components: Energy service gateway, Customer energy management system, DR/DER controller, Electric power generator and storage, Electric power load, and Customer electric power metre. The Operation domain contains one system: Utility grid and metre data mangement system. The Distribution domain contains one component: Utility grid electric power metre.
+
+Y.2072(18)\_F8-2
+
+**Figure 8-2 – Key system components of the energy-sharing and trading platform**
+
+A description of key systems and devices in each domain is given in clauses 8.1.7 to 8.1.11.:
+
+#### **8.1.7 Market**
+
+- DER energy-trading system
+ - This system sells the surplus power produced from the power generation source or the energy storage device owned by energy consumers in a home or public building to other energy consumers.
+ - It also arbitrates during the purchase of surplus power owned by other energy consumers.
+ - It mediates energy trading so that energy commodities (e.g., virtual energy sources integrated by small-scale distributed generation sources) can be sold to wholesale and retail operators.
+- DR energy-trading system
+ - This system mediates the sale or purchase of energy based on the customer baseline load (CBL) within the term of the DR contract. CBL means a normal consumption pattern when there is no enforced load reduction.
+- Renewable energy certificate (REC) trading system
+ - This system aims to distribute renewable energy supply among government-affiliated energy management agencies in each country to reduce carbon emissions. Renewable energy suppliers can issue certificates (i.e., RECs) and sell their certificates.
+NOTE – Existing generation operators (e.g., nuclear and thermal power plants) can directly produce renewable energy to keep the obligatory amount under its own power generation by government regulations or can obtain through the purchase of RECs.
+ - Under this regulatory environment, the system mediates the REC deal so that renewable energy providers are able to sell RECs to generation operators.
+
+#### **8.1.8 Service provider**
+
+- DR management system
+ - This system is for integrated management of demand reduction resources accumulated through contracts with energy consumers.
+ - It manages grouping resources with similar characteristics, depending on the load characteristics of demand reduction resources.
+ - It allows customers to participate in various DR programmes.
+- DER management and operation system
+ - This system is an integrated operations management system for large-scale virtual power generation sources through the accumulation of small-scale distributed generation sources that are distributed to homes or public buildings.
+ - The integration of small-scale power generation sources with no commercial value enables them to participate with bidding power equal to that of existing power generation sources in the electricity trading market as part of the virtual generation source.
+ - The integrated large-scale power generation resources are regularly monitored and the supply schedule is managed in accordance with the contract terms as an energy product.
+- Integrated EMS
+ - This system monitors in real-time generation of distributed energy sources and power consumption of the load resources simultaneously in homes or public buildings without their own EMSs.
+
+- It also analyses collected measurement data to predict customer as well as individual resource demands, and manages to minimize the maximum load power and energy consumption of the customer site.
+
+#### **8.1.9 Customer**
+
+- Energy service gateway
+ - This gateway is an interface device for interworking between service provider systems and EMSs within a customer's site.
+ - It also can support a dynamic application execution platform for provisioning energy management services in support of a service provider;
+ - The information (e.g., power measurement, resource status, operations and schedules, service providers' events) is delivered to a device within the customer's site or service provider system through this interface.
+- Customer EMS
+ - This system collects and analyses power production and consumption of customer energy resources from the power meter within a customer's site.
+ - It reduces peak load and energy consumption by forecasting the demand of the customer site based on analytical data.
+- DR/DER controller
+ - This controller controls energy production, storage and consumption devices within a customer site according to the operation schedule received from the DR and DER management systems.
+- Electric power generator and storage
+ - This generates and stores electric power within a customer site.
+- Electric power load
+ - This is a power consumption source within a customer site.
+- Customer electric power meter
+ - The meter measures electric power flows into and out of the utility grid at a customer site.
+ - It measures electric power generation and consumption of the energy resources within a customer site.
+
+#### **8.1.10 Operation**
+
+- Utility grid and meter data management system
+ - This system periodically collects and manages meter data from utility grid electric power meters.
+
+#### **8.1.11 Distribution**
+
+- Utility grid electric power meter
+ - This meter measures the electric power flows into and out of the utility grid at a customer site.
+
+### **8.2 Functional architecture for an energy-sharing and trading platform**
+
+An energy-sharing and trading platform has an important role for energy information exchanges between a seller (e.g., a producer) and a buyer (e.g., a consumer). As shown in Figure 8-3, the platform interacts with market participants (i.e., sellers and buyers) that are in charge of the production, storage and consumption of energy. Then, actual physical power is delivered between them based on the
+
+processing results of energy information for production control, charge/discharge control, optimal load management, etc.
+
+
+
+```
+
+graph LR
+ Seller((Seller
+(producer))) -- "Energy information" --> Platform[Energy sharing and trading platform]
+ Buyer((Buyer
+(consumer))) -- "Energy information" --> Platform
+ Seller <--> |"Physical power flow"| Buyer
+
+```
+
+Y.2072(18)\_F8-3
+
+Figure 8-3: A high-level view of an energy-sharing and trading platform. The diagram shows a central blue box labeled 'Energy sharing and trading platform'. To its left is a green circle labeled 'Seller (producer)' and to its right is a yellow circle labeled 'Buyer (consumer)'. Arrows labeled 'Energy information' point from both the Seller and the Buyer to the central platform. A double-headed arrow labeled 'Physical power flow' connects the Seller and the Buyer.
+
+**Figure 8-3 – A high-level view of an energy-sharing and trading platform**
+
+There are various actors as participants in an energy market:
+
+- generator: generate and (may also) store energy;
+- transmission/distribution operator: delivers electrical power from generator to consumer;
+- aggregator: a mediator in the energy market between power generators and consumers;
+- energy service provider: supports the business processes of generators, operators and consumers;
+- consumer: generates, stores energy and manages the use of energy in household, commercial building and industrial facilities.
+
+Based on key system components and various actors, the energy-sharing and trading platform has four main functional groups as follows:
+
+- Energy market functions
+ - Registration and advertisement of market participants' energy commodities.
+ - Contract bidding and purchase processing for sales of energy commodities.
+ - Sales and contract management of energy commodities based on energy measurement data.
+ - The final confirmation and settlement of selling/buying energy commodities.
+- Resource aggregator functions
+ - Resource registration and grouping of participating customers.
+ - Status monitoring, analysis and supply/demand forecast of participating customers' resources.
+ - Handling of DR events.
+ - Resource operations and schedule management in accordance with the terms and conditions of energy commodities.
+- Energy prosumer functions
+ - State information gathering and monitoring of power generation, storage and consumption resources within a customer site.
+ - Power generation and consumption measurement of the whole customer site and individual resources.
+ - Reception and treatment of resource aggregator events.
+ - Resource control schedule registration and schedule-based resource management.
+- Utility grid functions
+ - Measurement and management of customer site meter data on the utility grid.
+
+Figure 8-4 shows the four functions and their features described in the previous paragraph, including interactions between functional blocks.
+
+
+
+The diagram illustrates the key functions of an energy-sharing and trading platform, organized into three main functional groups and one utility grid functions block, with interactions between them.
+
+- Energy market functions** (top):
+ - Energy product registration
+ - Energy product advertisement
+ - Bidding management
+ - Contract management
+ - Delivery management
+ - Billing
+- Resource aggregator functions** (middle-left):
+ - Resource registration and grouping
+ - Resource group monitoring
+ - Energy demand and supply prediction
+ - Market event handling
+ - Resource group schedule handling
+- Utility grid functions** (middle-right):
+ - Metre data management
+- Energy prosumer functions** (bottom):
+ - Energy service gateway
+ - Aggregator event handling
+ - Resource monitoring
+ - Resource schedule handling
+ - Energy resource operation control
+ - Electric power metering
+
+**Interactions (Data and Event Flows):**
+
+- Energy market functions ↔ Resource aggregator functions:**
+ - Market and aggregator information (upward)
+ - Product information (upward)
+ - Bidding data (upward)
+ - Contract data (upward)
+ - Aggregator metering data (upward)
+ - Market event (downward)
+ - Billing event (downward)
+ - Billing event (upward)
+- Resource aggregator functions ↔ Energy prosumer functions:**
+ - Aggregator and energy prosumer information (upward)
+ - Resource state information (upward)
+ - Resource operation schedule (downward)
+ - Energy consumer metering data (upward)
+ - Aggregator event (downward)
+ - Utility metering data (downward)
+- Utility grid functions ↔ Energy prosumer functions:**
+ - Utility metering data (downward)
+
+Y.2072(18)\_F8-4
+
+Figure 8-4: Key functions of an energy-sharing and trading platform. The diagram shows three main functional groups: Energy market functions, Resource aggregator functions, and Energy prosumer functions, with a separate Utility grid functions block. Arrows indicate data and event flows between these groups.
+
+**Figure 8-4 – Key functions of an energy-sharing and trading platform**
+
+The four functional groups include the detailed features described in clauses 8.2.1 to 8.2.4.
+
+#### 8.2.1 Energy market functions
+
+- Energy product registration
+ - Information registration and management for energy commodities that participants (e.g., a resource aggregator or energy prosumer) in the energy market hold;
+ - Energy commodities comprise basic attribute information (e.g., the generated voltage, current, resource characteristics and the maximum power capacity) of each resource and resource group.
+- Energy product advertisement
+ - Notification of registered information related to energy commodities to energy market participants.
+ - Advertisement enables energy market participants to maintain up-to-date information for energy commodities.
+- Bidding management
+ - Registration management of energy commodity bidding information (e.g., the lowest bidding price, bid expiration time, generation schedule, generation capacity and resources quality condition);
+ - Notification of successful bid results to all participants through the management of participants bidding for each energy commodity.
+- Contract management
+
+- Control of energy market participation and energy commodity registration based on CBL and actual electricity usage patterns.
+- Integrated management for events (e.g., the terms and conditions change, contract cancellation and rebidding) that may occur before execution after contract signature.
+- Delivery management
+ - Management of the delivery of meter data from market participants.
+- Billing
+ - Calculation of the actual transaction volume compared to CBL and billing in accordance with the contractual conditions.
+
+#### **8.2.2 Resource aggregator functions**
+
+- Resource registration and grouping
+ - Registration and management of power generation and demand reduction resources that participating customers (e.g., energy prosumer and customer) hold.
+ - Resource grouping and energy commercialization based on resource characteristics.
+- Resource group monitoring
+ - Monitoring and analysis of the operation status of each resource group.
+- Energy demand and supply prediction
+ - Energy demand pattern and supply forecasting of participating customers based on environmental information (e.g., climate) and historical data.
+- Market event handling
+ - Handling of energy market events, such as market price and grid reliability information.
+- Resource group schedule handling
+ - Operation schedule management for the resources of the participating customers in accordance with the terms and conditions of energy commodities.
+
+#### **8.2.3 Energy prosumer functions**
+
+- Energy service gateway
+ - An interface for transmitting power measurement data, resource status information, operating schedules and energy market events between resource aggregator and energy prosumer.
+- Aggregator event handling
+ - Processing of the event (e.g., DR event or resource operation schedule registration event) received from a resource aggregator.
+- Resource monitoring
+ - Operation status monitoring of power generation, storage and consumption resources within a customer site.
+- Resource schedule handling
+ - Operation scheduling of power generation, storage and consumption resources within a customer site.
+- Energy resource operation control
+ - Integrated control of power generation, storage and consumption resources in accordance with the resources operating schedules.
+
+- Electric power metering
+ - Measurement of power generation and power consumption through the participating customer's electric power meter installed at the customer site.
+
+#### 8.2.4 Utility grid functions
+
+- Meter data management
+ - Measurement and management of customer power generation and consumption through utility grid electric power meters.
+
+# 9 Mechanisms for energy information exchange
+
+The rapid increase and spread of renewable energy sources and ESS provide opportunities for energy prosumers to create added value through surplus energy trading. To this end, the energy-sharing and trading platform for energy prosumers has capabilities for monitoring energy consumption facilities, energy storage devices and renewable energy sources within the customer domain, as well as integrating with the energy market, service provider systems and DR/DER control devices.
+
+The energy-sharing and trading platform provides a standard interface for matching with various standard protocols to support interworking. Based on this standard interface, the energy-sharing and trading platform is able to:
+
+- monitor various energy consumption and supply resources and control a group of these resources;
+- balance the energy demand and supply of customer domains;
+- sell surplus resources across the market.
+
+Figure 9-1 shows the four important features and data management items provided in the energy-sharing and trading system. Related standards from different stakeholders are interfaced to support interoperability with external systems and devices.
+
+
+
+```
+
+graph TD
+ subgraph Platform [Energy sharing and trading platform]
+ EBT[Energy balancing and trading]
+ RAC[Resource aggregation and control]
+ RMM[Resource monitoring and measurement]
+ CPA[Communication protocol adaptation]
+ end
+
+ subgraph Database [Data repository Database]
+ EP[Energy price, products, bids, transaction states]
+ DR[DR and DER resource states, operation schedules]
+ EM[Energy metre and billing data, customer information]
+ end
+
+ subgraph External [External Systems]
+ EMkt[Energy markets]
+ SP[Service providers]
+ EPsum[Energy prosumers]
+ UP[Utility providers]
+ end
+
+ Platform <-->|EI, OpenADR| EMkt
+ Platform <-->|EI, OpenADR| SP
+ Platform <-->|EI, OpenADR, SEP, Modbus, BACnet| EPsum
+ Platform <-->|DNP3, IEC 61968| UP
+
+```
+
+Y.2072(18)\_F9-1
+
+Figure 9-1: Energy information exchange in an energy-sharing and trading platform. The diagram shows a central platform box with four internal modules: Energy balancing and trading, Resource aggregation and control, Resource monitoring and measurement, and Communication protocol adaptation. To the right is a Data repository (Database) with three sections: Energy price, products, bids, transaction states; DR and DER resource states, operation schedules; and Energy metre and billing data, customer information. Below the platform are four external entities: Energy markets, Service providers, Energy prosumers, and Utility providers. Bidirectional arrows connect the platform to each entity, with associated protocols: EI, OpenADR for Energy markets and Service providers; EI, OpenADR, SEP, Modbus, BACnet for Energy prosumers; and DNP3, IEC 61968 for Utility providers.
+
+**Figure 9-1 – Energy information exchange in an energy-sharing and trading platform**
+
+## 9.1 Communication protocol adaptation
+
+- An energy-sharing and trading platform serves as a bridge or gateway platform connecting energy prosumer devices with service providers, energy markets, and utility providers. To this end, the communication protocol adaptation layer supports existing standard protocols
+
+[e.g., energy interoperation (EI)] and provides an abstracted common service interface for interworking with other systems and devices to upper layers:
+
+- this layer serves as a communication interface to support interworking with key system components of the energy-sharing and trading platform shown in Figure 8-4;
+- this layer supports standard information models and communication protocols [e.g., EI, open automated demand response (OpenADR), and smart energy profile (SEP)] for DR/DER management services and energy trading;
+- this layer also supports standard information models and communication protocols {e.g., the distributed network protocol 3 (DNP3) [b-IEEE 1815] and IEC 61968 [b-IEC 61968-9]} to collect energy metering information from utility grid management servers and energy meters.
+
+## **9.2 Energy resource monitoring and measurement**
+
+- Energy-sharing and trading platforms need to monitor the status of energy resources in an integrated manner. The performance and safety status of each managed resource should be periodically checked, and the power consumption and supply of each resource should be measured and collected. The energy resource monitoring and measurement layer performs the following roles:
+ - this layer serves as a resource information collector to gather and monitor the status of DER through the abstracted common service interface provided by the communication adaptation layer;
+ - this layer collects power generation and consumption information measured by electric power meters;
+ - the utility grid electric power meter measures the total amount of power consumed and generated at the customer site, and the customer electric power meter measures the amount of power generated by each distributed resource.
+
+## **9.3 Resource aggregation and control**
+
+- Energy-sharing and trading platforms need to integrate various resources to create one virtual bulk generation resource considering their characteristics. The resource aggregation and control layer performs the following roles:
+ - this layer groups and controls resources according to the DR programme or considering the characteristics of the individual resources registered;
+ - this layer serves as a DER manager to effectively cluster and control distributed resources by monitoring their availabilities and analysing driving probabilities based on the collected resource state information;
+ - this layer schedules the demand reduction of DR resources and controls them according to the schedule;
+ - this layer also controls the DER contracted through the energy market to manage the operating schedule of the resources.
+
+## **9.4 Energy balancing and trading**
+
+- The energy-sharing and trading platform balances the power demand and supply within the management domain by maximizing the available DR resources, power generation resources and energy storage devices within the management domain. In addition, energy prosumers provide opportunities to create added value through surplus energy trading within the management domain. To this end, the energy balancing and trading layer performs the following roles:
+
+- this layer regulates the power demand and supply balance of the management domain by using the real-time status information of the managed energy resources;
+- this layer calculates an actual amount of power, generated by the DER on the managed customer domain, in comparison with a contracted amount of power, using the data measured from electric power meters – it also determines whether the actual amount of power generated by the DER falls within an acceptable limit of the contracted amount of power;
+- this layer also serves as a DR manager configured to receive an electricity demand reduction instruction message notified from the DR market system, monitor a state of the DR resources and perform a DR control, as well as setting an electricity demand reduction and electricity generation schedule so that an electricity consumption can be within the range of the contracted target value;
+- this layer compares the DR capacity target value with a maximum DR capacity prediction value to determine whether to purchase electricity to make up for a shortfall in DR capacity.
+
+## 9.5 Data repository
+
+- The energy-sharing and trading platform carries out the four core functions in clause 9.4 to efficiently maintain the integrated demand and supply balance in the process of energy production, storage, consumption and transaction management.
+- The data repository stores information about the following three essential management items:
+ - energy market information: energy price, energy products, bids, transaction states;
+ - energy resource information: energy resource states, resource group information, resource operation schedules, resource availability, operation probability;
+ - energy metering and customer information: customer information, billing data, energy measurement data.
+
+# 10 Security considerations
+
+The security considerations of an energy-sharing and trading platform should be in accordance with the security requirements in [ITU-T X.1111] and [ITU-T Y.2701]. General security requirements and technologies are described in [ITU-T X.1111]. This Recommendation applies the technologies in [ITU-T X.1111] to the key system components of an energy-sharing and trading platform.
+
+An energy-sharing and trading platform should take into account aspects of physical, system and operational security as follows:
+
+- verifying the identity of an entity (e.g., user, process or device) for accessing resources in a system for the energy-sharing and trading platform;
+- determining the adequacy of security requirements and ensuring compliance with the established security policy and procedures for an energy-sharing and trading platform;
+- authorization to use various services in a system for an energy-sharing and trading platform;
+- supporting cryptography and validation mechanisms for data integrity in an energy-sharing and trading platform;
+- providing the privacy considerations with respect to an energy-sharing and trading platform.
+
+# Appendix I
+
+## A possible system model for an energy-sharing and trading platform
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix illustrates a possible system model for an energy-sharing and trading platform. An energy-sharing and trading platform is implemented by various systems and related standard interfaces and protocols.
+
+Figure I.1 shows an example of the overall system model for an energy-sharing and trading platform. The system consists of three main sub-systems: an energy-trading server (ETS), energy-trading client (ETC) and energy-integrated management system (EIMS). Each subsystem has related functional modules for supporting energy trading between sellers and buyers.
+
+For energy-trading services requiring the sharing of energy information, standard interfaces are used as follows:
+
+- interface between ETS and ETC [i.e., a virtual top node-virtual end node (VTN-VEN) interface];
+- internal interface in ETS and ETC (i.e., VTN-ESTS interface, VEN-ESTC interface);
+- external interface for EIMS (i.e., ETC-EIMS interface).
+
+
+
+Figure I.1 illustrates the system overview of an energy-sharing and trading platform, showing three main subsystems and their internal components and interfaces.
+
+**Energy trading server (ETS):**
+
+- Energy information portal service (EIPS)
+- Energy trading operation service (ETOS)
+- Energy information shading and trading server service (ESTS)
+- Energy trading server communication module (VTN)
+
+**Energy trading client (ETC):**
+
+- Energy information participants service (ETPS)
+- Energy information shading and trading client service (ESTC)
+- Energy trading server communication module (VEN)
+
+**Energy integrated management system (EIMS):**
+
+- Energy service provider service (ESPS)
+- Energy integrated management application service (EIMA)
+- Energy integrated management core service (EIMC)
+- Building/complex management and control communication module (MCCM)
+
+**Interfaces:**
+
+- VTN-ESTS interface:** Connects ESTS in ETS to VTN in ETS.
+- VTN-VEN interface:** Connects VTN in ETS to VEN in ETC.
+- VEN-ESTC interface:** Connects ESTC in ETC to VEN in ETC.
+- ETC-EIMS interface:** Connects ETC to EIMS.
+- EIMC-MCCM interface:** Connects EIMC in EIMS to MCCM in EIMS.
+
+**Legend:**
+
+- VTN-VEN interface (Blue double-headed arrow)
+- ETS, ETC internal interface (Yellow double-headed arrow)
+- External EIMS interface (Red double-headed arrow)
+
+NOTE – VTN: Virtual top node, VEN: Virtual end node, EMIX: Energy market information exchange, EI: Energy interoperation
+
+Y.2072(18)\_Fl.1
+
+Figure I.1: System overview of an energy-sharing and trading platform. The diagram shows three main subsystems: Energy trading server (ETS), Energy trading client (ETC), and Energy integrated management system (EIMS). ETS contains EIPS, ETOS, ESTS, and VTN modules. ETC contains ETPS, ESTC, and VEN modules. EIMS contains ESPS, EIMA, EIMC, and MCCM modules. Interfaces include VTN-ESTS, VTN-VEN, VEN-ESTC, ETC-EIMS, and EIMC-MCCM. A legend at the bottom defines the interface types: VTN-VEN (blue double-headed arrow), ETS/ETC internal (yellow double-headed arrow), and External EIMS (red double-headed arrow).
+
+**Figure I.1 –System overview of an energy-sharing and trading platform**
+
+## I.1 ETS
+
+An ETS consists of three services:
+
+- Energy information portal service (EIPS)
+The EIPS provides energy profiles including key statistics, policies and actors.
+- Energy-trading operation service (ETOS)
+An ETOS is a server to support energy-trading operations.
+- Energy information sharing and trading server service (ESTS)
+
+An ESTS provides services on the server side to support energy information sharing and trading.
+
+## **I.2 ETC**
+
+- Energy-trading participants service (ETPS)
+
+An ETPS provides client support for participation in energy trading.
+
+- Energy information sharing and trading client service (ESTC)
+
+An ESTC provides services on the client side to support energy information sharing and trading.
+
+## **I.3 EIMS**
+
+- Energy service provider service (ESPS)
+
+An ESPS providing energy services to final customers, including the supply and installation of energy efficient equipment or building refurbishment, has started to operate on the energy market.
+
+- Energy-integrated management application service (EIMA) and energy-integrated management core service (EIMC)
+
+An EIMA and EIMC provide applications and core services for energy-integrated management, including risk identification and management, planning, training, reporting, auditing and review in the energy-trading process.
+
+## **I.4 Energy-trading communication module**
+
+- Server entity is a VTN
+
+ETS communication module.
+
+- Client entity is a VEN
+
+ETC communication module.
+
+## **I.5 Energy information exchange protocols**
+
+- Energy market information exchange (EMIX)
+
+An EMIX provides methods for exchanging energy characteristics, availability and schedules to support the free and effective exchange of information. [b-OASIS EMIX] defines an information model and extensible markup language (XML) vocabulary for the interoperable and standard exchange of prices and product definitions in transactive energy markets: price information, bid information, time for use or availability, units and quantity to be traded, characteristics of what is traded.
+
+- EI
+
+[b-OASIS EI] describes information and communication models to enable collaborative and transactive use of energy, service definitions consistent with the OASIS service-oriented architecture (SOA) reference model, and XML vocabularies for the interoperable and standard exchange of: dynamic price signals, reliability signals, emergency signals, communication of market participation information such as bids, load predictability and generation information.
+
+- WS-Calendar
+
+WS-Calendar describes a semantic (or information) model for exchange of calendar information to coordinate activities and a means of synchronizing and maintaining calendars. [b-OASIS WS-Calendar] includes XML vocabularies for the interoperable and standard exchange of: schedules, including sequences of schedules, intervals, including sequences of intervals, other calendar information consistent with the IETF iCalendar standards.
+
+## Bibliography
+
+- [b-ITU-T Smart-O-30] ITU-T FG-Smart Grid: Smart-O-30Rev.6 (2011), Deliverable on smart grid terminology.
+[https://www.itu.int/en/ITU-T/focusgroups/smart/Documents/smart-o-0030r6-terminology\\_deliv.doc](https://www.itu.int/en/ITU-T/focusgroups/smart/Documents/smart-o-0030r6-terminology_deliv.doc)
+- [b-IEEE 1815] IEEE Std 1815-2012, *IEEE Standard for electric power systems communications – Distributed network protocol (DNP3)*.
+- [b-IEC 61968-9] IEC 61968-9:2013, *Application Integration at electric utilities – System interfaces for distribution management – Part 9: Interfaces for meter reading and control*.
+- [b-NIST 1108] NIST Special Publication 1108 (2016), *Framework and roadmap for smart grid interoperability standards, Release 3.0*.
+- [b-OASIS EI] OASIS EI (2014), *Energy interoperation*. Version 1.0.
+- [b-OASIS EMIX] OASIS EMIX (2012), *Energy market information exchange (EMIX)*. Version 1.0.
+- [b-OASIS WS-Calendar] OASIS WS-Calendar (2011), *WS-Calendar*. Version 1.0.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1e615cfafcf8516f881d29248448deedbd7fe937
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:89976934ead7b9a439606a32c6f55a97ffe42a32bd88a094e7c6628de3dc94b5
+size 51208
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9a620d9333549e0587dd4f43ccd47501fb6a9739
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3c9de6ca5e8a0ddb2c40412fa9099c5be4964bfed91aac7a70b087158563751c
+size 66672
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4f7fca45e6886f784c7d0e5af3d70b3c077cb1ac
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2f6e7587ee35b06737e2b1c268d289ceb9d8f28cd2db8bb63b6d72c9ce851afe
+size 29876
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..de2ba47631c6589b2245a0ecad2f37a76317cb07
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1a6e3e571711673e03bcdbb5eb93f4154459772a1069b65fa22bf2f995ca832d
+size 6963
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a0678c7de8f3faefbd4ea9bf8b3e55bd440f1f88
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e5bb5ddc575c93c042d76f2750d65a881dd0bf8691bb579c8466e29ae6420923
+size 86790
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e08d0f73bfc9b1019fca171946d8147b0fc7cc90
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1903c2ab39d4d27cc482f54a93c57a35ecf83fc576d7598cd9879d2e9e25b17d
+size 26352
diff --git a/marked/Y/T-REC-Y.2076-201602-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..326ade6185ab23cf95408e1654ca3bdd3eac0d18
--- /dev/null
+++ b/marked/Y/T-REC-Y.2076-201602-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:761da575a4e05e45a79a869fca5b945dc6abd592a59916653f4520c6d2ce22d3
+size 107100
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3c0550ca1da20a4060e10c2fc7b6744440f0c439
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3ffdd621c33a1c7341813396be9e915c9125b3c1f722bda09c6cfb4005b2f87f
+size 35184
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..825bf871df2f948867a6ee453633dd74911f72cd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0482a3eb5ccd93ede46d6d65fae0a26512c766be4eff9039d3f1610731f1cbd7
+size 33787
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/365b54f616aff249b4e6c0edafdcb9b3_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/365b54f616aff249b4e6c0edafdcb9b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d71ee79d2ecc6c9055bdc2317df63ec254453d9c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/365b54f616aff249b4e6c0edafdcb9b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5b3464e83a358897fd1b77b6f9e9b1008a59b6441518984d43d12610066e5a93
+size 72069
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..aaf2bd046df8baee462c4ac79467d518e8f3247d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/474a819357587e34949a3e110ff19b30_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:471803645dc8c9b0202fc32f0b6d6a7fec73329c879956a55cb5acb5c3153c66
+size 46635
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4baac80ed02557fd739494777a0f6af3c180b5cb
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5b0b35053e886450f1898ff34be9c5ac043606c05bec7420d492017f84dd083
+size 73414
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b3e5e8852fc325cc79253692351d5f4c655088f4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4e9f59f37af678fc96644e9f56c3a655011e123c3bee9b8fadbff8abb76e6bd0
+size 34471
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a4df08607d42664cedc7a5b085d993b6cfddeed1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:096dd1cfb500359d703415db22974bd682e56ed683c43b235fb7ac7b8657ab5c
+size 49901
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0fb1ce4accb9980d4699b128bec606300ac0d75b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:86d5eedf756cdd45cb16b2163d3e3defa820049e6b2caefc83cb7aaaf593152f
+size 41520
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8dcaaa2809644bc30ca0d7287a9096ef594fa988
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/7f25db95ce3916c0e09803b861a2f7bc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2e7ec83e0c733855c298f9818a2637c26b19aa2d443d248ab124cb5c1cf739a8
+size 42184
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..88632c154204f67da91984ae4bc7c6d4bacd146f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4a006e6f541012ec09ec506c707d47fbf22a22469942f80690151a7e0af06316
+size 6792
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..106b50912d89d09eafe026a22d14081000e7cfae
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bb4b4c6f03c941998bea91499baf8c24debca38353306513c4a748f11ea9c47d
+size 53351
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4304491c5d58b17abe32b35c6b8022f0a77d05b0
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a3d1bbcf018893ff620752220e3fb44cfa23598e9e1e97996d9b6d4567120f17
+size 37007
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/d9843ac5dfc4bbe9e4d21b8898723b5e_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/d9843ac5dfc4bbe9e4d21b8898723b5e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bc1b2c349e79d6ef5ec10c49b1236c2110d0bd8a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/d9843ac5dfc4bbe9e4d21b8898723b5e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d009afa03f434d2d98f34ea9bf681dd21c0769544d665e42744b5028ddea280a
+size 76988
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6793bf54dba0703835442cf6fefd624b3d3a7cd6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:06b32f3dd0f754940dc65794df6940e5371f5d9fe9606b7f098f03b541451a12
+size 42861
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..883012ff0ab8ee50dce3b53b88a3b5e245c96c37
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:82e0fb4644b0644f10f395418bc60c338af899723604ef514304e64c8d86ab05
+size 139383
diff --git a/marked/Y/T-REC-Y.2113-200901-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..c6594acbee48c9be00903156716ae0a842bf92f9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2113-200901-I_PDF-E/raw.md
@@ -0,0 +1,1009 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.2113
+
+(01/2009)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Quality of Service and
+performance
+
+# --- **Ethernet QoS control for next generation networks**
+
+Recommendation ITU-T Y.2113
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with a red lightning bolt striking it, and the text "ITU" in blue. To the right of the globe, the words "International Telecommunication Union" are written in a smaller blue font.
+
+ITU logo
+
+## ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## **Recommendation ITU-T Y.2113**
+
+# **Ethernet QoS control for next generation networks**
+
+## **Summary**
+
+Recommendation ITU-T Y.2113 specifies dynamic Ethernet quality of service (QoS) control for next generation networks. Specifically, it defines service definitions and general requirements, a QoS control architecture, and a set of traffic management mechanisms for Ethernet-based NGNs. Related OAM and protection and restoration mechanisms are specified by reference to other Recommendations.
+
+###### **Source**
+
+Recommendation ITU-T Y.2113 was approved on 23 January 2009 by ITU-T Study Group 13 (2009-2012) under Recommendation ITU-T A.8 procedures.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+### INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2009
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | | Page |
+|----|----------------------------------------------------------------------------|-------------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 5 |
+| 6 | Concept and general requirements for the Ethernet-based NGN ..... | 5 |
+| | 6.1 Definition of Ethernet-based NGN concept ..... | 5 |
+| | 6.2 General requirements for Ethernet-based NGN service..... | 5 |
+| 7 | QoS architecture for the Ethernet-based NGN ..... | 6 |
+| | 7.1 Introduction ..... | 6 |
+| | 7.2 Reference model..... | 6 |
+| | 7.3 VPN configuration..... | 9 |
+| | 7.4 High layer switching..... | 14 |
+| | 7.5 Access control ..... | 15 |
+| 8 | Traffic management for Ethernet-based NGN ..... | 15 |
+| | 8.1 Overview ..... | 15 |
+| | 8.2 Ethernet QoS services..... | 15 |
+| | 8.3 Ethernet traffic management functions ..... | 16 |
+| | 8.4 Traffic management mechanism for edge side..... | 17 |
+| | 8.5 Traffic management mechanisms for core side..... | 19 |
+| | 8.6 Connection admission control (CAC) ..... | 20 |
+| | 8.7 Resource reservation procedure ..... | 21 |
+| | 8.8 Ethernet traffic grooming ..... | 21 |
+| 9 | Operation, administration and maintenance for the Ethernet-based NGN ..... | 21 |
+| 10 | Ethernet protection and restoration for the Ethernet-based NGN ..... | 22 |
+| 11 | Security consideration ..... | 22 |
+| | Appendix I – Example of access control mechanism ..... | 23 |
+| | Appendix II – Example scenarios of resource reservation procedure ..... | 25 |
+| | Bibliography..... | 27 |
+
+
+
+# Recommendation ITU-T Y.2113
+
+# Ethernet QoS control for next generation networks
+
+# 1 Scope
+
+This Recommendation addresses Ethernet quality of service (QoS) control for next generation networks. It specifies the following:
+
+- Service definitions and general requirements for Ethernet-based NGNs.
+- Reference model of QoS architecture for Ethernet-based NGNs.
+- Traffic management mechanisms for Ethernet-based NGNs.
+- Operation, administration and maintenance (OAM) mechanisms for Ethernet-based NGNs.
+- Protection and restoration mechanisms for Ethernet-based NGNs.
+
+The OAM and protection and restoration mechanisms are specified by reference to other Recommendations.
+
+Ethernet-based NGN is broadly characterized as the employment of IP protocols for the control of Ethernet data flows. In the data link layer, data link features and interfaces defined in [b-IEEE 802.3] will not be altered.
+
+As considered in this Recommendation, the Ethernet network encompasses not only the customer's local network but also the operator's access and core networks, which are assumed to employ Ethernet technology.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T G.7041] | Recommendation ITU-T G.7041/Y.1303 (2005), Generic framing procedure (GFP) . |
+| [ITU-T G.8001] | Recommendation ITU-T G.8001/Y.1354 (2008), Terms and definitions for Ethernet frames over transport . |
+| [ITU-T G.8010] | Recommendation ITU-T G.8010/Y.1306 (2004), Architecture of Ethernet layer networks . |
+| [ITU-T G.8011] | Recommendation ITU-T G.8011/Y.1307 (2004), Ethernet over Transport – Ethernet services framework . |
+| [ITU-T G.8012] | Recommendation ITU-T G.8012/Y.1308 (2004), Ethernet UNI and Ethernet NNI . |
+| [ITU-T G.8021] | Recommendation ITU-T G.8021/Y.1341 (2007), Characteristics of Ethernet transport network equipment functional blocks . |
+| [ITU-T G.8031] | Recommendation ITU-T G.8031/Y.1342 (2006), Ethernet linear protection switching . |
+
+- [ITU-T G.8032] Recommendation ITU-T G.8032/Y.1344 (2008), *Ethernet ring protection switching*.
+- [ITU-T Y.1221] Recommendation ITU-T Y.1221 (2002), *Traffic control and congestion control in IP-based networks*.
+- [ITU-T Y.1541] Recommendation ITU-T Y.1541 (2006), *Network performance objectives for IP-based services*.
+- [ITU-T Y.1730] Recommendation ITU-T Y.1730 (2004), *Requirements for OAM functions in Ethernet-based networks and Ethernet services*.
+- [ITU-T Y.1731] Recommendation ITU-T Y.1731 (2006), *OAM functions and mechanisms for Ethernet based networks*.
+- [ITU-T Y.2012] Recommendation ITU-T Y.2012 (2006), *Functional requirements and architecture of the NGN release 1*.
+- [ITU-T Y.2111] Recommendation ITU-T Y.2111 (2006), *Resource and admission control functions in Next Generation Networks*.
+- [IEEE 802.1Q] IEEE Standard 802.1Q (2005), IEEE standard for local and metropolitan area networks – *Virtual Bridged Local Area Networks*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+None.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 Ethernet user to network interface (E-UNI):** An interface that uses the Ethernet frame structure between a user (an end user or a customer network) and a network element of the transport network.
+
+**3.2.2 Ethernet network to network interface (E-NNI):** An interface that uses the Ethernet frame structure between network elements within separate transport networks.
+
+**3.2.3 Ethernet virtual connection (EVC):** An instance of an association of two or more E-UNIs. These E-UNIs are said to be "in the EVC". A given UNI can support more than one EVC via the service multiplexing attribute.
+
+NOTE – This terminology is used in a different way as defined in [ITU-T G.8011] and [ITU-T G.8001].
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations:
+
+| | |
+|-------|-------------------------------------------|
+| AAA | Authentication, Authorization, Accounting |
+| AR | Access Rate |
+| ARP | Address Resolution Protocol |
+| ATM | Asynchronous Transfer Mode |
+| B-Tag | Backbone VLAN Tag |
+| BW | Bandwidth |
+
+| | |
+|--------|--------------------------------------------|
+| CAC | Connection Admission Control |
+| CBR | Constant Bit Rate |
+| CBS | Committed Burst Size |
+| CE | Customer Edge |
+| CF | Coupling Flag |
+| CIR | Committed Information Rate |
+| CL-PS | Connectionless, Packet-Switched |
+| CM | Colour Mode |
+| CMTS | Cable Modem Termination System |
+| CO-CS | Connection Oriented, Circuit-Switched |
+| CO-PS | Connection Oriented, Packet-Switched |
+| CoS | Class of Service |
+| CPE | Customer Premises Equipment |
+| C-Tag | Customer VLAN Tag |
+| C-VID | Customer VLAN ID |
+| DSL | Digital Subscriber Line |
+| DSLAM | Digital Subscriber Line Access Multiplexer |
+| E-AF | Ethernet Assured Forwarding |
+| E-DF | Ethernet Default Forwarding |
+| E-EF | Ethernet Expedited Forwarding |
+| E-LAN | Ethernet LAN |
+| E-LINE | Ethernet Line |
+| E-NNI | Ethernet Network to Network Interface |
+| E-PHB | Ethernet Per-Hop Behaviour |
+| E-Tree | Ethernet Tree |
+| E-UNI | Ethernet User to Network Interface |
+| EAP | Extensible Authentication Protocol |
+| EAPoL | EAP over LAN |
+| EBS | Excess Burst Size |
+| EIR | Excess Information Rate |
+| EPL | Ethernet Private Line |
+| EPLAN | Ethernet Private LAN |
+| EVC | Ethernet Virtual Connection |
+| EVPL | Ethernet Virtual Private Line |
+| EVPLAN | Ethernet Virtual Private LAN |
+| FRS | Frame Relay Service |
+| GFP | Generic Framing Procedure |
+
+| | |
+|---------|----------------------------------------------|
+| GGSN | Gateway GPRS Support Node |
+| GMPLS | Generalized MultiProtocol Label Switching |
+| GPRS | General Packet Radio Service |
+| I-Tag | Backbone Service Instance Tag |
+| ID | Identifier |
+| IP | Internet Protocol |
+| LDP | Label Distribution Protocol |
+| LSP | Label Switched Path |
+| MAC | Media Access Control |
+| MBS | Maximum Burst Size |
+| MPLS | MultiProtocol Label Switching |
+| NACF | Network Attachment Control Function |
+| NGN | Next Generation Network |
+| nrt-VBR | non real-time Variable Bit Rate |
+| OAM | Operation, Administration and Maintenance |
+| OTH | Optical Transport Hierarchy |
+| P-Tag | Provider Tag |
+| PAE | Port Access Entity |
+| PD-FE | Policy Decision Functional Entity |
+| PDH | Plesiochronous Digital Hierarchy |
+| PE-FE | Policy Enforcement Functional Entity |
+| PE | Provider Edge |
+| PNNI | Private Network to Network Interface |
+| QoS | Quality of Service |
+| RACF | Resource and Admission Control Functions |
+| RADIUS | Remote Authentication Dial In User Service |
+| RARP | Reverse Address Resolution Protocol |
+| RSVP | Resource ReserVation Protocol |
+| S-Tag | Service VLAN Tag |
+| SCF | Service Control Functions |
+| SDH | Synchronous Digital Hierarchy |
+| SGSN | Serving GPRS Support Node |
+| SLA | Service Level Agreement |
+| SONET | Synchronous Optical Network |
+| TE | Traffic Engineering |
+| TPID | Tag Protocol Identifier |
+| TRC-FE | Transport Resource Control Functional Entity |
+
+| | |
+|------|-----------------------------|
+| UNI | User to Network Interface |
+| VBR | Variable Bit Rate |
+| VC | Virtual Connection |
+| VLAN | Virtual Local Area Network |
+| VPLS | Virtual Private LAN Service |
+| VPN | Virtual Private Network |
+
+# 5 Conventions
+
+None.
+
+# 6 Concept and general requirements for the Ethernet-based NGN
+
+## 6.1 Definition of Ethernet-based NGN concept
+
+The key idea of Ethernet-based NGN is to use the Ethernet frame format throughout an NGN transport network. No format conversion occurs during the end-to-end delivery of Ethernet frames. Without a change in the basic Ethernet frame format, it is required that the Ethernet header fields contain information of QoS provisioning as specified in [IEEE 802.1Q] in order to support the control and management functions of NGN. Ethernet-based NGN means the network using the Ethernet technology through any physical media, including fixed and wireless environments in the NGN transport stratum. The Ethernet-based NGN services are various services provided by network operators using Ethernet transport networks. Figure 1 illustrates the generic architecture model and services of Ethernet-based NGN. The Ethernet is a transfer medium for core transport as well as the access transport of NGN.
+
+It is optional that non-Ethernet-based access networks (e.g., DSL) are connected to Ethernet-based core networks. However, non-Ethernet-based access network technologies are beyond the scope of this Recommendation.
+
+
+
+```
+
+graph TD
+ subgraph Services
+ I[Internet]
+ H[HDTV, TVoD and VoD]
+ G[Gaming, Business Backup, ERP]
+ V[Voice / Video Telephony]
+ W[Wireless Backbone]
+ end
+
+ ECN(Ethernet based Core Networks)
+ EBAN(Ethernet based Access Networks)
+
+ ECN --- I
+ ECN --- H
+ ECN --- G
+ ECN --- V
+ ECN --- W
+
+ ECN --- EBAN
+ EBAN --- CPNB[CPN for Business Broadband]
+ EBAN --- CPNSMB[CPN for Small / Medium Business]
+ EBAN --- CPNR[CPN for Residential]
+
+ EBAN --- W2[Broadband mobile data / video]
+
+```
+
+Figure 1: Generic architecture model and services of Ethernet-based NGN. The diagram shows a central 'Ethernet based Core Networks' oval connected to five service boxes at the top: 'Internet', 'HDTV, TVoD and VoD', 'Gaming, Business Backup, ERP', 'Voice / Video Telephony', and 'Wireless Backbone'. Below the core is an 'Ethernet based Access Networks' oval, which is connected to three cloud-shaped boxes: 'CPN for Business Broadband', 'CPN for Small / Medium Business', and 'CPN for Residential'. A wireless tower icon is shown connected to the access network, with a label 'Broadband mobile data / video'.
+
+**Figure 1 – Generic architecture model and services of Ethernet-based NGN**
+
+## 6.2 General requirements for Ethernet-based NGN service
+
+The general requirements for the Ethernet-based NGN service fall into two categories: user equipment and network.
+
+User equipment is required to:
+
+- Support the same Ethernet frame format for fixed and wireless transport interfaces while various transport technologies are applied.
+- Provide auto-discovery capability such as ARP/RARP.
+- Provide the relevant QoS/TE requesting capability with traffic parameters according to SLA depending on the applications.
+- Provide Ethernet frame tagging using IEEE 802.1Q VLAN tags for the Ethernet traffic management.
+
+The network is required to:
+
+- Support capabilities of OAM, protection and restoration, and load sharing.
+- Support the VPN capability. The existing VLAN can be extended or changed to support the NGN core network.
+- Provide an auto-configuration capability such as neighbour discovery.
+- Provide access control capability based on the MAC address and/or VLAN ID including security.
+- Provide the traffic contract function and QoS class mapping between access networks and core networks.
+- Provide the Ethernet traffic management mechanisms to guarantee the requested QoS/TE requirements depending on the different Ethernet services.
+
+# **7 QoS architecture for the Ethernet-based NGN**
+
+## **7.1 Introduction**
+
+It is required that the QoS architecture for Ethernet-based NGN meets the following control and management requirements:
+
+- Flexible connection configuration and bandwidth allocation:
+ - Dynamic provision for end-to-end connectivity.
+ - Priority, access control, security protection.
+ - TE/QoS handling for acceptable end-to-end quality.
+- Various VPN services:
+ - Access control, QoS and security according to VPN services.
+- Integration of switching capabilities:
+ - TE/QoS, routing, control processing.
+ - Binding of MAC address and VLAN ID.
+
+Ethernet-based NGN depends on the QoS/TE capabilities of each layer. For example, the QoS/TE capability of IP over Ethernet over SDH depends on IP QoS/TE (layer 3), Ethernet QoS/TE (layer 2), and SDH QoS/TE (layer 1) capabilities. Therefore, the QoS/TE mappings between different layer protocols are important.
+
+## **7.2 Reference model**
+
+Figure 2 shows the reference model for Ethernet-based NGN by focusing on dynamic QoS control [ITU-T Y.2012], [ITU-T G.8010] and [ITU-T Y.2111]. The interface between the customer and the operator is an Ethernet user-to-network interface (E-UNI). Ethernet services are offered by concatenating a number of operator networks. The interfaces between different operator networks are Ethernet network-to-network interfaces (E-NNIs).
+
+Figure 2-a illustrates a case where the access and core networks are managed by the same operator (i.e., are in a single administrative domain), and Figure 2-b illustrates a case where there are multiple network operators. In both Figure 2-a and Figure 2-b, it is possible that the functional entities TRC-FE and PD-FE reside in the access transport and core transport.
+
+All reference points and functional entities specified in [ITU-T Y.2111] apply to the Ethernet-based NGN defined in this Recommendation. In particular, the Rn reference point, which is transport-technology dependent, is required to support information components such as network connectivity, transfer characteristics, link type, traffic separation, connectivity monitoring, bandwidth profile, UNI list, preservation, survivability as defined in [ITU-T G.8011]. The details of the Rn reference point specific to the Ethernet transport are for further study.
+
+
+
+**a) Single network operator case**
+
+The diagram shows a single network operator case. At the top is the Service stratum with SCF. Below it is the Transport stratum, separated by a dashed line. The Transport stratum contains RACF, which includes PD-FE and TRC-FE. NACF is connected to RACF via Ru. SCF is connected to RACF via Rs. RACF is connected to Transport Network A via Rn, Rc, and Rw. Transport Network A is connected to CPE X and CPE Y via E-UNI. The Transport Function layer is at the bottom.
+
+**b) Multiple network operator case**
+
+The diagram shows a multiple network operator case. At the top are two Service strata: SCF A and SCF B. Below them are two Transport strata, separated by a dashed line. The Transport strata contain RACF A and RACF B, which include PD-FE A and TRC-FE A, and PD-FE B and TRC-FE B. NACF A is connected to RACF A via Ru. SCF A is connected to RACF A via Rs. SCF B is connected to RACF B via Rs. RACF A is connected to Transport Network A via Rn, Rc, and Rw. RACF B is connected to Transport Network B via Rn, Rc, and Rw. Transport Network A is connected to CPE X via E-UNI. Transport Network B is connected to CPE Y via E-UNI. The Transport Function layer is at the bottom.
+
+Figure 2 – Reference model of Ethernet-based NGN. The diagram is divided into two parts: a) Single network operator case and b) Multiple network operator case. Both parts show a layered architecture with Service stratum, Transport stratum, and Transport Function layers. In the single operator case, all components are within one domain. In the multiple operator case, components are distributed across two domains (A and B).
+
+**Figure 2 – Reference model of Ethernet-based NGN**
+
+The E-UNI is an Ethernet interface in both the physical layer and media access control (MAC) layer. Ethernet frames exchanged across the E-UNI are formatted as defined in [IEEE 802.1Q]. Ethernet frames are untagged or tagged with VLAN tag control information. VLAN tag control information consists of the VLAN ID and user priority bits (commonly referred to as p-bits). The frames defined in [IEEE 802.1Q], however, are inadequate to support OAM and protection of VPN services. Therefore, the Ethernet frame from the E-UNI is encapsulated in the link layer payload at the E-NNI. Frame encapsulation is further described in clause 7.3.6. Ethernet frames are transported inside the transport network using the deployed native transport technology. It is optional that the transport technology is CO-CS (connection oriented, circuit-switched), CO-PS (connection oriented, packet-switched), or CL-PS (connectionless, packet-switched). Table 1 lists some examples of the different transport technologies that are currently deployed.
+
+**Table 1 – Examples of transport technologies and services**
+
+| Technology | Examples |
+|------------|----------------|
+| CO-CS | SONET, SDH |
+| CO-PS | ATM, FRS, MPLS |
+| CL-PS | Ethernet |
+
+For CO-CS, Ethernet frames are encapsulated using the generic framing procedure (GFP) [ITU-T G.7041] frame encapsulation. Ethernet frames are then transparently transported across the circuit-switched networks. For packet-switched transport, Ethernet frames are encapsulated and forwarded using a native transport technology, e.g., ATM.
+
+### 7.2.1 Bandwidth profile
+
+Figure 3 shows an example of bandwidth profile per service attributes. The bandwidth profile applies to all of the frames per E-UNI, E-NNI, EVC, CoS, physical port or L2/L3 information. Multiple bandwidth profiles exist simultaneously at the E-UNI/E-NNI. However, for a given frame, only one bandwidth profile will apply.
+
+
+
+Diagram illustrating bandwidth profiles per service attribute. A central vertical cylinder represents the E-UNI/E-NNI interface. To its right, three horizontal cylinders represent EVCs (EVC 1, EVC 2, EVC 3). EVC 1 contains two CoS (CoS 1, CoS 2). EVC 2 contains one CoS (CoS 1). EVC 3 contains no CoS. A vertical double-headed arrow on the left of the E-UNI/E-NNI cylinder is labeled 'Bandwidth profile per E-UNI/NNI'. A vertical double-headed arrow on the right of EVC 1 is labeled 'Bandwidth profile per CoS'. A vertical double-headed arrow on the right of EVC 2 is labeled 'Bandwidth profile per port or L2/L3 information'. A vertical double-headed arrow on the right of EVC 3 is labeled 'Bandwidth profile per EVC'.
+
+**Figure 3 – Bandwidth profile per service attribute**
+
+### 7.2.2 Ethernet virtual connection (EVC)
+
+The EVC extends between two E-UNIs. Across the E-UNI, one or more VLAN IDs are mapped to the same EVC. An EVC supports multiple CoSs as identified by p-bits. Service classes vary in terms of their QoS requirements. Each of those service classes is considered a separate CoS instance.
+
+It is required that an EVC has one of four possible types with respect to class of service and bandwidth profile:
+
+- Single-CoS EVC wherein all frames belonging to EVC are treated in the same manner and transported with equal bandwidth profile.
+- Single-CoS EVC with multiple bandwidth profiles wherein frames belonging to EVC are treated in the same manner but are transported with different bandwidth profiles.
+- Multi-CoS EVC with a single bandwidth profile wherein frames are treated differently according to their classes of service, even as all frames are transported with equal bandwidth profile.
+- Multi-CoS EVC with multiple bandwidth profiles, wherein frames are treated differently according to their classes of service, and frames are transported with CoS-designated bandwidth profile.
+
+In the case of single-CoS EVC with multiple bandwidth profiles, input frames from E-UNI are untagged frames that have the same priority, whereas bandwidth profiles can be assigned based on physical ports or L2/L3 information (e.g., MAC address, IP address).
+
+### **7.2.3 Ethernet user to network interface (E-UNI)**
+
+E-UNI is the interface as defined in clause 3.2. A single E-UNI supports several EVCs destined for different destinations. Similar to EVC, it is required that E-UNI has one of four types with respect to class of service and bandwidth profile.
+
+### **7.2.4 Ethernet network to network interface (E-NNI)**
+
+The E-NNI is the interface as defined in clause 3.2. A single E-NNI supports more than one EVC destined for different destinations. Similar to EVC, it is required that E-NNI has one of four types with respect to class of service and bandwidth profile.
+
+It is possible that E-NNI's OAM and fault handling use policies as inputs. In such a case, protection and restoration behaviour varies depending on the policies for each connection and/or EVC.
+
+E-NNI's OAM and fault handling include the following functions:
+
+- Transfer of performance information.
+- Transfer of fault information.
+- Performance monitoring.
+- Fault management.
+
+The related information is exchanged according to the tag field of the frames. To be mapped with E-UNI classes using the IEEE 802.1Q format, it is required that E-NNI supports at least 8 classes of service.
+
+## **7.3 VPN configuration**
+
+A VPN delivers a multipoint-to-multipoint Ethernet service that can span one or more metro areas and provides connectivity between multiple sites as if they were attached to the same Ethernet LAN. Unlike the current Ethernet multipoint-to-multipoint service delivered over network operator infrastructure consisting of Ethernet switches, it is possible that a VPN uses the MPLS network operator infrastructure [b-IETF RFC 2917]. From the network operator's point of view, the use of QoS routing protocols and procedures instead of the spanning tree, protocol and MPLS labels instead of VLAN IDs within the network operator infrastructure, result in significant improvements in the scalability of VPN as a service.
+
+### 7.3.1 VPN reference model
+
+Figure 4 shows the reference model of a VPN. The network operator transports the Ethernet frames between CEs belonging to the same VPN through the tunnel. The VPN creates groups of users that are separated from other network users and communicate among them as if they were attached to the private network.
+
+
+
+Figure 4 – Reference model of VPN. The diagram illustrates a network topology for a VPN. On the left, two Customer Edges (CEs) are shown: CE 1 (VPN A) and CE 3 (VPN B). These are connected to a Provider Edge (PE) node, PE 1, via E-UNI interfaces. PE 1 is connected to a core network consisting of two Provider (P) nodes and another PE node, PE 2. The connections between PE 1 and the first P node, between the two P nodes, and between the second P node and PE 2 are labeled E-NNI. A Tunnel is established between the two P nodes. On the right, two more CEs are shown: CE 2 (VPN A) and CE 4 (VPN B), connected to PE 2 via E-UNI interfaces. A Virtual Connection (VC) is indicated as a long arrow spanning from PE 1 to PE 2. The entire setup is labeled as the VPN at the bottom.
+
+**Figure 4 – Reference model of VPN**
+
+A VPN is composed of CE (customer edge), PE (provider edge) and P (provider core node). The explanation for each device is as follows:
+
+- CE has the functionality needed on the CPE to access the services specified by the VPN.
+- PE has the functionality needed on the edge of the network operator to interface with the CE.
+- P is a node in the core network that does not have interfaces to customers.
+- VC (virtual connection) is an identifier used to distinguish Ethernet frames transferred by a tunnel that belongs to a particular VPN. A VC label is assigned to the Ethernet frames based on VLAN ID or port ID.
+- A tunnel is established in a core network for transferring Ethernet frames among the P nodes.
+
+### 7.3.2 VPN configuration requirements
+
+Typical VPN topologies include point-to-point, point-to-multipoint, multipoint-to-multipoint, mixed (e.g., partial mesh) and hierarchical. VPN configuration requirements are as follows:
+
+- It is required that VPNs support unicast traffic. It is optional that VPNs support broadcast and multicast traffic.
+- When VPN spans multiple administrative domains, it is required that the VPN service be able to act and appear as a single, homogeneous VPN from the customer point of view.
+- VPN transports the encapsulated traffic of Ethernet frames. It is required that the VPN header, with the exception of the source MAC address, be preserved transparently from source to destination.
+- It is recommended that the security features supported by VPN be configurable on a per-customer basis.
+- It is required that QoS provisioning be supported.
+
+### 7.3.3 VPN functions
+
+The following VPN functions are required.
+
+- Configuration between VLAN priority and MPLS CoS:
+VLAN priority bits are mapped into the corresponding MPLS CoS fields and vice versa. Such mapping is configured automatically or manually at both ingress and egress nodes based on the policy of network operators.
+- Auto-discovery:
+Auto-discovery is critical to enable network operators to minimize operational costs, since it automates the creation of VPNs.
+The new PE joins a VPN when the VPN instance is configured on that PE, with one or more customer-facing ports on that PE associated with such a VPN instance. In this case, PE advertises that it is part of the VPN domain via the route reflector to other PEs joined in such a VPN instance. At this time, all appropriate PEs are "aware" of the new PE and these PE members now have all the information they need to configure the VPN with the new PE automatically.
+- MAC address learning:
+MAC address learning for configuring VPN is a method of disseminating MAC addresses to discover network devices through a plurality of network switches that co-operate to enable maintaining multiple active paths between such devices. Newly discovered MAC addresses are attached to the ports of an edge switch for dissemination through the network switches. When an edge switch detects a device with a previously unknown MAC address, a MAC address information packet is generated and disseminated. The received MAC address information packet is used to update the MAC address tables in the receiving switch. Afterward, the received MAC address packet is forwarded from each receiving intermediate switch to other neighbour switches in the load balance domain.
+- Full mesh tunnelling:
+Although it offers multipoint connectivity, the VPN is created with a full mesh of point-to-point pseudo-wires between the participating operator edge routers. The VPN uses an MPLS core; on the edges, it multiplexes and creates pseudo-wires to each router participating in the VPN network. As a result, a full mesh of pseudo-wires is required to support the service. Signalling for VPN relies on control sessions between edge routers for setting up and maintaining connections. Tunnel labels, making up the unidirectional tunnel label switched path (LSP), are established with link LDP or RSVP-TE signalling. The appropriate control protocol is used to perform signalling and session negotiation between tunnel endpoints.
+- VPN multicast:
+The general goal of multicast is to employ a tree-like delivery channel to avoid multiple transmissions over the same physical links. The VPN multicast configuration consists of one multicast tree per VPN or one per suitable set of VPNs. It is required that all multicast applications within the VPN forward the multicast packets along the tree to all respective PEs.
+
+### 7.3.4 QoS parameter mapping between E-UNI and E-NNI
+
+During the VPN set-up, it is required that the ingress node map the QoS parameters of the E-UNI tag information into those of the E-NNI tag information.
+
+It is required that the egress node consider the priority and CoS fields of the E-NNI tag information when queuing the frame at the VLAN bound. Figure 5 shows some examples.
+
+
+
+The diagram shows three columns of ovals representing QoS parameters at different stages: VLAN QoS (left), MPLS CoS (middle), and VLAN QoS (right). Three service levels are listed on the left: Premium Service, Gold Service, and Best Effort Service. Arrows indicate the mapping of these services across the stages. For Premium Service, there is a direct arrow from the first to the second and third ovals, and a cross-connection from the second to the first. For Gold Service, there is a direct arrow from the first to the second and third ovals, and a cross-connection from the second to the first. For Best Effort Service, there is a direct arrow from the first to the second and third ovals.
+
+Diagram illustrating QoS parameter mapping between VLAN QoS, MPLS CoS, and VLAN QoS. It shows three service levels: Premium Service, Gold Service, and Best Effort Service. Arrows indicate mapping paths between the three stages, showing both direct and cross-mappings.
+
+**Figure 5 – Example of QoS parameter mapping**
+
+An ingress node supports the ability to carry Ethernet VPN as a best-effort service over the MPLS network [b-IETF RFC 4664] and [b-IETF RFC 4665]. The priority field of the VLAN is kept transparent between ingress node device and egress node device regardless of the QoS support of the core network.
+
+If the VLAN field is added at the egress node, it is required that a default priority field setting of zero is supported and a configured default value is recommended. Otherwise, it is possible that the value is mapped from the CoS field of the core network.
+
+An ingress node supports additional QoS through one or multiple CoS per VPN service. As a policy of the VPN network operator based on an agreement with the customer, the guaranteed rate is different from the Ethernet physical port rate.
+
+Examples of the QoS mapping relationship in the VPN service include:
+
+- The classification to CoS is based on the VLAN field regardless of the VLAN priority bits. The CoS is assigned to a specific value based on the VPN policy.
+- The classification to the CoS is based on the VLAN field and priority bits.
+
+### 7.3.5 VPN service models
+
+VPN services are supported by the E-LINE (Ethernet line service), E-LAN (Ethernet LAN) and E-Tree service using EVC. A VPN ID is assigned globally and uniquely to an E-LINE, an E-LAN or an E-Tree service shared by the designated group of customers. VPN ID is associated with a specific level of CoS to deliver the same or equivalent QoS to all customers of VPN across different domains of network operators.
+
+NOTE – E-LINE, E-LAN and E-tree services are differently defined in [ITU-T G.8011] from the viewpoint of E-UNI.
+
+- E-LINE service:
+Point-to-point EVC between two E-UNIs can create EPL (Ethernet private line) and EVPL (Ethernet virtual private line) services using the E-LINE service type. For these services, Ethernet flow is delivered to an MPLS tunnel according to the given VLAN ID or default VLAN ID depending on the tagged or untagged port. The EPL service provides a high degree of transparency for service frames between E-UNIs. On the other hand, the EVPL service does not need full transparency for the service frames due to permission of service multiplexing at E-UNI, which allows more than one EVC to be supported at E-UNI.
+
+Figure 6 shows an example of the E-Line service model. This figure illustrates three point-to-point EVCs: EVC1, EVC2, and EVC3. A point-to-point EVC is an EVC with exactly two E-UNIs. CE means equipment on the customer side of the E-UNI. CE 1 means equipment on the customer side of the E-UNI.
+
+
+
+Figure 6: E-Line service model diagram. A central 'Transport Network' oval contains three point-to-point EVCs: EVC 1 (connecting E-UNI A and E-UNI C), EVC 2 (connecting E-UNI A and E-UNI D), and EVC 3 (connecting E-UNI C and E-UNI D). Customer Equipment (CE 1, CE 2, CE 3, CE 4) is connected to these E-UNIs. A 'Service Multiplexing' oval groups E-UNI A and E-UNI C, with a note: 'Service Multiplexing allows one E-UNI to support multiple EVCs.' A legend states: 'EVC1, EVC 2, EVC 3 : Point-to-Point EVC'.
+
+**Figure 6 – E-Line service model**
+
+#### - E-LAN service:
+
+Multipoint-to-multipoint EVC can be used to provide the E-LAN service. The E-LAN service is inherently for multipoint-to-multipoint VPN such that the MPLS multicasting function is supported [b-IETF RFC 4761] and [b-IETF RFC 4762]. For this service, a group address is set per MPLS tunnel, per VLAN, per VPN, etc.
+
+The E-LAN service is classified by EPLAN (Ethernet private LAN) and EVPLAN (Ethernet virtual private LAN) service. EPLAN service provides dedicated connectivity for multipoint LANs. In the case of EVPLAN services, each E-UNI supports multiple VLANs, as well as both point-to-point and multipoint connections [b-MEF6]. Figure 7 shows an example of EPLAN service, providing multipoint-to-multipoint connectivity across the transport networks between a pair of non-service multiplexed E-UNIs. A multipoint-to-multipoint EVC is an EVC with more than two E-UNIs.
+
+
+
+Figure 7: E-LAN service model diagram. A central 'Transport Network' oval contains a single 'Multipoint-to-Multipoint EVC' that connects all four E-UNIs (A, B, C, D). Customer Equipment (CE 1, CE 2, CE 3, CE 4) is connected to these E-UNIs. A note states: 'An E-LAN Service requires only one EVC to achieve multi-site connectivity.'
+
+**Figure 7 – E-LAN service model**
+
+#### - E-Tree service:
+
+In an E-Tree multipoint EVC, one E-UNI is designated as the roots, and all the others are designated as leaf nodes. Ingress service frames at a root are delivered to any leaf nodes in the EVC. Ingress service frames at a leaf are only delivered to the root. Leaf nodes do not
+
+send frames to each other directly. Frames sent from two leaf nodes are delivered through the root. E-Tree service is inherently a point-to-multipoint VPN which provides an MPLS multicasting function [b-IETF RFC 3353]. For this kind of service, a group address is set according to per MPLS tunnel, per VLAN, every VPN.
+
+Figure 8 shows an example of the E-Tree service model. In this example, the point-to-multipoint EVC allows multiple leaf E-UNIs to communicate with the same root E-UNI simultaneously.
+
+
+
+Figure 8: E-Tree service model diagram. It shows a central 'Transport Network' represented by a large oval. Four 'CE' (Customer Edge) boxes are connected to the network. One CE at the top is connected to a 'Root E-UNI' on the network boundary. Three other CEs (left, bottom-left, and bottom-right) are connected to 'Leaf E-UNI' on the network boundary. A dashed line connects the Root E-UNI to the Leaf E-UNIs, forming a tree structure. An arrow points from the text 'Rooted-Multiple EVC' to the tree structure. Below the diagram, text states: 'An E-Tree Service requires only one EVC to achieve multi-site connectivity'.
+
+**Figure 8 – E-Tree service model**
+
+### 7.3.6 Frame encapsulation in the VPN
+
+To support VPN services, Ethernet frames are encapsulated in the link layer payload at the E-NNI for transport across the core networks.
+
+Figure 9 shows the required frame encapsulation in support of VPN services. C-Tag is the customer VLAN Tag, which includes a TPID and C-VID as specified in [IEEE 802.1Q]. P-Tag could be the MPLS label or provider-specified label. The frame type at the E-UNI is one of untagged frame, priority tagged frame or tagged frame of [IEEE 802.1Q]. A frame is mapped to a tagged frame representing C-tag and the tagged frame is encapsulated in the P-tag frame at the PE. It is optional that the link header is added to the P-tag frame depending on the type of link layer.
+
+
+
+Figure 9: Frame encapsulation in VPN diagram. It illustrates the mapping of frame fields from E-UNI to PE and then to E-NNI. At the E-UNI level, there are two frames: one with fields DA, SA, VLAN, and M\_SDU; the other with DA, SA, and M\_SDU. At the PE level, these are mapped to frames with DA, SA, C-Tag, and M\_SDU. The PE level also shows frames with P-Tag, DA, SA, and M\_SDU. At the E-NNI level, the frames are encapsulated into 'Link header' and 'Link payload' blocks. Dashed lines show the mapping of fields between these levels.
+
+**Figure 9 – Frame encapsulation in VPN**
+
+## 7.4 High layer switching
+
+While the layer 3 switch performs IP-based routing, layer 4~7 switching capabilities forward packets to appropriate destinations based on the upper layer information. Unlike layer 2 or layer 3 switching, the upper layer information is utilized to make switching decisions. Through the analysis of TCP/UDP port information (HTTP, FTP, Telnet, SMTP, POP3, etc.), layer 4 switching delivers packets with the same destination IP address to different destinations in a local domain.
+
+Furthermore, layer 4 information can be used to prioritize and queue traffic. Layer 7 switching looks inside the application layer field to make forwarding decisions. Depending on the contents, such as HTTP contents, cookie information, FTP file names and e-mail titles, traffic can be directed to different paths. The major benefits provided by layer 4~7 switching capabilities are failover of various servers and network security by preventing monopoly over network resources.
+
+Support of layer 4~7 switching capabilities requires the binding of the Ethernet MAC address with a high layer service. Multiple Ethernet MAC addresses can be assigned to the same destination IP address and/or port number. By examining the information on the high layer, a mapping rule given by a switch operator finds a proper destination Ethernet MAC address.
+
+## **7.5 Access control**
+
+Network access control makes use of the physical access characteristics to provide the means for authenticating and authorizing devices attached to a physical port and to prevent access to a such port in cases wherein the authentication and authorization process fails. Examples of ports wherein the use of authentication can be desirable include the ports of MAC bridges and the ports used to attach directly to the LAN.
+
+It is recommended that access control be based on [b-IEEE 802.1X]. Appendix I provides further information.
+
+# **8 Traffic management for Ethernet-based NGN**
+
+## **8.1 Overview**
+
+Users can select or request their own QoS/TE with the relevant parameters from the network operator. CAC requires the knowledge of certain parameters to operate efficiently. In particular, it is recommended that the network operator's transfer capability, the source traffic descriptor, connection admission priority and the requested QoS classes are taken into account.
+
+A network operator's capability, a source traffic descriptor, and an associated QoS class are declared by the user at connection establishment by means of signalling or subscription.
+
+For a given network operator's connection, the source traffic descriptor belonging to the traffic contract and all parameter values of this source traffic descriptor are the same at all standardized interfaces along the connection.
+
+To meet QoS commitments, a conformance definition is specified at the AAA server for any given network operator's transfer capability. A conformance definition also pertains to each standardized network-to-network interface. A traffic contract applies to an Ethernet virtual flow. Therefore, the conformance definition at an interface applies to the level where the traffic contract is defined. The conformance definition also covers the reverse connection.
+
+CAC is operator specific. Once the connection has been accepted, the value of CAC and E-UNI/E-NNI parameters are set by the network based on the network operator's policy.
+
+## **8.2 Ethernet QoS services**
+
+Edge mechanisms and network forwarding classes are combined to define a set of Ethernet QoS services. Service categories are defined by specifying the traffic parameters, edge rules, network forwarding classes and other corresponding IP QoS parameters. Table 2 shows the Ethernet QoS services.
+
+**Table 2 – Ethernet QoS services**
+
+| Ethernet QoS service | Traffic parameter | Edge rule | Forwarding class (Associated DiffServ PHB) | Y.1221 transfer capability | Y.1541 IP QoS class |
+|-----------------------------|---------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------|---------------------------------------|----------------------------|
+| Premium service | CIR > 0 CBS > 0 EIR = 0 EBS = 0 | Drop non-conforming frames | E-EF | Dedicated bandwidth | QoS classes 0, 1, 6 and 7 |
+| Gold service | CIR > 0 CBS > 0 EIR > 0 EBS > 0 | Admit non-conforming frames up to EIR. Excess frames are assigned high discard precedence | E-AF with minimum bandwidth assurances. No delay bound. Drop excess frames first in case of congestion. | Delay-sensitive statistical bandwidth | QoS classes 2, 3 and 4 |
+| Best-effort service | CIR = 0 CBS = 0 EIR > 0 (possibly equal physical rate) EBS > 0 (large) | All frames are admitted with high discard precedence | E-DF No bandwidth assurances. No delay bound. Drop first in case of congestion. | Best effort | QoS class 5 (unspecified) |
+
+The premium service is useful for those applications requiring stringent bounds on both frame loss and frame delay. The service does not allow excess frames (defined as frames that are non-conforming to CIR) into the network. It is most suitable for EPL (Ethernet private line) application as defined in [ITU-T G.8012] on SDH networks. In this case, frame discard precedence is invisible to the nodal mechanism and there is nothing to be gained from allowing frames in the network with different discard precedence.
+
+The gold service provides some bandwidth assurances but not any delay bounds. In that respect, it is similar to the traditional frame relay service or ATM nrt-VBR service category. This service is useful for the EVPL (Ethernet virtual private line) application that requires some bandwidth assurance but is not sensitive to delay.
+
+The best-effort service supports the other applications that are not sensitive to delay and delay variation.
+
+As the first column of Table 2, Ethernet QoS service is recommended to be mapped into the corresponding ITU-T Recommendations, [ITU-T Y.1541] and [ITU-T Y.1221]. These parameters are consistent with those of [b-MEF6].
+
+## 8.3 Ethernet traffic management functions
+
+Figure 10 shows the architecture for Ethernet traffic management. This figure illustrates both the service and transport stratum functions.
+
+When the service control function (SCF) receives a request for the Ethernet-based NGN services, the SCF determines the QoS requirements for the service and informs the RACF. The RACF performs policy-based transport resource control upon the request of the SCF. The RACF interacts with transport functional entities to control traffic conditioning functions in the transport layer.
+
+The access and/or core transport functions perform traffic conditioning for QoS control based on the policy rules received from the RACF. The traffic conditioning includes traffic classification, metering, marking and dropping/shaping.
+
+The conformance of the Ethernet frames received at E-UNI is verified using a metering function. Based on the output of the metering, it is possible that an Ethernet frame is coloured, recoloured or dropped depending on its conformance. Frames are then marked with the appropriate core forwarding class and proceed to the network.
+
+
+
+The diagram illustrates the architecture for Ethernet traffic management, divided into two main strata: Service Stratum and Transport Stratum.
+
+- Service Stratum:** Contains a **Service User Profile** (cylinder) and a **Service Control Function** (rectangle). They are connected by a dashed line.
+- Transport Stratum:** Contains a **Transport User Profile** (cylinder) and a **RACF** (Resource Allocation Control Function) block. The RACF block contains a **Policy Decision (PD-FE)** and a **Transport Resource Control (TRC-FE)** sub-block. The Service Control Function is connected to the Policy Decision sub-block.
+- Access Transport (AN/EN-FE) & Core Transport (ABG/IBG-FE):** This block contains the traffic processing logic:
+ - Classifier:** Receives traffic from the **EVC** (Edge Virtual Circuit).
+ - Metering:** Receives control signals from the Policy Decision and TRC-FE sub-blocks. It sends control signals to the Classifier and the Dropper/shaper.
+ - Marking:** Receives control signals from the Policy Decision and TRC-FE sub-blocks. It receives media flow from the Classifier.
+ - Dropper / shaper:** Receives control signals from the Policy Decision and TRC-FE sub-blocks. It receives media flow from the Marking block.
+- Output:** Traffic flows from the Dropper / shaper to **To Other Networks**.
+- Legend:** Dashed lines represent **Control** paths, and solid lines represent **Media** paths.
+
+Architecture for Ethernet traffic management diagram showing Service and Transport Stratum layers.
+
+**Figure 10 – Architecture for Ethernet traffic management**
+
+Traffic management mechanisms are also divided into those mechanisms implemented on the edge of the networks at the interface between the customer and the operator, and those implemented inside the network to ensure that the traffic volume does not exceed the bandwidth and to treat frames based on their performance requirements.
+
+## 8.4 Traffic management mechanism for edge side
+
+Traffic management mechanisms on the operator edge are usually concerned with ensuring that the customer submitted traffic classification adheres to a certain traffic pattern (conformance definition) and within the parameter values (traffic parameters), as agreed upon between the customer and the operator.
+
+It is required that some actions (edge rules) are taken when the customer's traffic exceeds the assigned parameter values. Such actions usually involve dropping or marking the excess frame with a discard eligibility flag.
+
+The main components of the edge mechanisms are collectively referred to as traffic conditioning as described in [ITU-T G.8021]. In its general form, the traffic conditioning function consists of the traffic classifier, metering, marker, dropper and shaper functions shown as in Figure 10. The following describes each of the edge functions as illustrated above.
+
+### 8.4.1 Traffic classification and mapping
+
+To identify the sequences of frames (or flows) and correlate such sequences with the traffic parameters, conformance, actions and network behaviour, traffic conditioning starts with classification.
+
+Classification is based solely on layer 2 (Ethernet) quantities or makes use of elements of higher layers, e.g., IP. It is optional that it is also based on an EVC or the entire E-UNI.
+
+Ethernet frames are either tagged or untagged. Tagged frames will contain the tag control information field. Both a VLAN ID and user priority bits in the field can be used for flow classification. For instance, frames with certain VLAN ID values are assigned to certain traffic parameters and network behaviour. VLAN ID values are mapped or encapsulated in LABEL and are transferred through an MPLS-based core transport network. For the case of Ethernet-based core transport networks utilizing the provider bridge and/or the provider backbone bridge, it is required that a VLAN ID be mapped to another tag (S-Tag in the provider bridge [b-IEEE 802.1ad], I-Tag or B-Tag in the provider backbone bridge [b-IEEE 802.1ah]). This mapping procedure is executed on the network edge router or access gateway by referring to the mapping table.
+
+### 8.4.2 Ethernet traffic parameters and conformance definition
+
+Service traffic parameters are usually associated with rate parameters as well as the corresponding measuring period. The measuring period can be expressed explicitly in seconds, i.e., rate parameters are measured over a time window of a fixed length. Alternatively, the measuring period can be stated in terms of the amount of traffic expected at a given rate.
+
+The MEF technical specification [b-MEF10.1] defines CIR (committed information rate) and EIR (excess information rate). Related to CIR and EIR are the committed burst size (CBS) and excess burst size (EBS). Frames are accepted at the access rate (AR) as long as they are within their burst sizes. Otherwise, frames are declared to be non-conformant based on the conformance definition. There is some similarity with the FRS (frame relay service) parameters in the sense that both the CIR and EIR concepts are used. However, they differ from the FRS parameters in terms of the absence of a specified time period over which parameters are measured.
+
+The function of the conformance definition is to determine the conformance of incoming frames to the service parameters. The conformance definition is a deterministic algorithm providing a deterministic upper bound, or a deterministic envelope, on the amount of traffic admitted to the network. A deterministic upper bound is necessary for network resource management and satisfying performance requirements.
+
+For a sequence of ingress Ethernet frames with arrival times $t_j$ and lengths $l_j$ , where $j \geq 0$ , the colour assigned to each frame during traffic conditioning is defined by using the algorithm shown in Figure 11 [b-MEF10.1]. For this algorithm, $B_c(t_0) = CBS$ and $B_e(t_0) = EBS$ . $B_c(t)$ and $B_e(t)$ are the number of bytes in the committed and excess token buckets, respectively, at a given time $t$ .
+
+In addition, there are two optional parameters used to determine the behaviour of the algorithm, coupling flag (CF) and colour mode (CM) as defined in [ITU-T G.8021], but not shown in the Figure 11 for simplicity.
+
+
+
+Frames of length $l_j$ arrives at $t_j$
+
+```
+
+graph TD
+ Start([Frames of length $l_j$ arrives at $t_j$ ]) --> Calc[
+$$B_c(t_j) = \min\{CBS, B_c(t_{j-1}) + \frac{CIR}{8} \times (t_j - t_{j-1})\}$$
+
+
+$$B_e(t_j) = \min\{EBS, B_e(t_{j-1}) + \frac{EIR}{8} \times (t_j - t_{j-1})\}$$
+]
+ Calc --> Dec1{ $l_j \leq B_c(t_j) ?$ }
+ Dec1 -- Yes --> Green[Declare frame Green
+ $B_c(t_j) = B_c(t_{j-1}) - l_j$ ]
+ Dec1 -- No --> Dec2{ $l_j \leq B_e(t_j) ?$ }
+ Dec2 -- Yes --> Yellow[Declare frame Yellow
+ $B_e(t_j) = B_e(t_{j-1}) - l_j$ ]
+ Dec2 -- No --> Red[Declare frame Red]
+
+```
+
+Flowchart of the Ethernet metering and marking algorithm. A frame of length l\_j arrives at time t\_j. First, bucket levels are updated: B\_c(t\_j) = min{CBS, B\_c(t\_{j-1}) + (CIR/8) \* (t\_j - t\_{j-1})} and B\_e(t\_j) = min{EBS, B\_e(t\_{j-1}) + (EIR/8) \* (t\_j - t\_{j-1})}. Then, a decision is made: if l\_j <= B\_c(t\_j), the frame is declared Green and B\_c(t\_j) is updated to B\_c(t\_{j-1}) - l\_j. If not, a second decision: if l\_j <= B\_e(t\_j), the frame is declared Yellow and B\_e(t\_j) is updated to B\_e(t\_{j-1}) - l\_j. If neither condition is met, the frame is declared Red.
+
+**Figure 11 – Ethernet metering and marking algorithm**
+
+### 8.4.3 Edge rules
+
+It is required that frames deemed non-conforming according to the conformance definition are acted upon in a certain manner. There are usually two actions associated with non-conforming frames: dropping or marking.
+
+With dropping, non-conforming frames are not allowed to proceed beyond the edge node of the operator network. Non-conforming frames are dropped or no excess traffic is allowed in the network.
+
+With marking, non-conforming frames are marked for discard eligibility. Discard-eligible frames are allowed in the network under the condition that no performance assurances are extended to them. Discard-eligible frames are to be dropped first when the network is in a congestion state. The volume of discard-eligible frames is usually limited, e.g., by EIR to avoid exhausting the network resources and affecting upper-layer performance negatively.
+
+The choice between dropping and marking has a significant impact on the service offered.
+
+## 8.5 Traffic management mechanisms for core side
+
+It is required that the operator's core network is equipped with traffic management capabilities that enable satisfying the performance objectives on a frame-by-frame basis. Traffic management mechanisms inside the operator's core network are those related to transmission scheduler, buffer management and admission control.
+
+It is recommended that traffic engineering is supported over the end-to-end transfer. Still, offering continuous traffic engineering for the different parameters of E-UNI and E-NNI is difficult. Thus, it is required that parameter mapping is done on edge routers or access gateways. Basically, traffic flows are aggregated or divided during the bridging of the different network interfaces. Traffic classification depends on the network operator's policy.
+
+### 8.5.1 Ethernet per-hop behaviour (E-PHB)
+
+Transmission scheduling and buffer management are usually referred to as nodal behaviour (in the context of the IP differentiated service, they are referred to as the per-hop behaviour (PHB)). Transmission scheduling has to do with what frame has to be transmitted first and what portion of the transmission facility has to be reserved for a particular flow or group of flows. Buffer management is concerned with the acceptance of incoming packets to a nodal buffer based on the current buffer fill and the packet-discard eligibility.
+
+There are two main approaches for identifying the type of behaviour applied to each packet, the stateful and stateless approaches. The stateful approach is based on a connection identifier. A connection identifier determines the connection where the incoming packet belongs as well as the type of behaviour that applies to it. One example is the ATM/MPLS traffic management wherein, e.g., the MPLS label is used to define the connection and service category to which a packet belongs, e.g., CBR connection. This method requires keeping the context tables inside the node that correlates the label to its service category.
+
+The second method is the one applied to the IP differentiated services where the packet carries in its header an indication as to what type of treatment is applied to it, e.g., priority treatment. All packets with the same bit pattern receive the same treatment from the node. This technique is perceived to be more scalable than the stateful approach.
+
+In this clause, the differentiated service approach is extended to the Ethernet. For the case of tagged Ethernet frames, there are 3 user priority bits in the tag control information. Such bits can be used in a variety of ways to support a number of E-PHBs. Similar to differentiated service PHB, it is optional that E-PHB includes the following:
+
+- Ethernet expedited forwarding (E-EF), which is suitable for implementing services requiring frames to be delivered with minimum delay and loss bounds. No reordering of frames is allowed.
+- Ethernet assured forwarding (E-AF), which defines a number of classes with a number of discard precedences associated with each class. No reordering of frames is allowed.
+- Ethernet default forwarding (E-DF), which is suitable for implementing services with no performance assurances, e.g., best effort. No reordering of frames is allowed.
+
+Buffer management includes the provisions required to handle short- and long-term congestion. Short-term congestion is handled by buffering incoming frames during those brief periods when the frame input rate to the node exceeds the nodal bandwidth. Long-term congestion is handled by dropping the packets based on their discard eligibility. It is optional that the nodal discard algorithm includes active queue management or simple drop thresholds based on the supported applications.
+
+## 8.6 Connection admission control (CAC)
+
+The main function of connection admission control (CAC) is to limit the number of connections accepted by the network. It can limit the amount of traffic submitted to the network and consequently offers a better opportunity for satisfying the QoS requirements of the accepted connections. CAC is based on traffic parameters and QoS requirements. As mentioned earlier, traffic parameters are important because they impose a deterministic upper bound on connection traffic, thus allowing for the accurate prediction of the required resources.
+
+## 8.7 Resource reservation procedure
+
+There are two resource reservation procedures for Ethernet-based NGN service: SCF-triggered reservation and CPE-triggered reservation. Those reservation procedures are the same as those defined in [ITU-T Y.2111]:
+
+### - SCF-triggered reservation:
+
+The CPE can perform service QoS negotiation (such as bandwidth) through service signalling, but is unaware of QoS attributes specific to the transport. The service QoS concerns characteristics pertinent to the application. (e.g., SIP phone with SDP [b-IETF RFC 4566]/SIP QoS extensions [b-IETF RFC 3312]).
+
+In the SCF-triggered QoS resource reservation mechanism, the SCF sends a resource initiation request to RACF to invoke the QoS resource authorization and reservation. The RACF will push the admission control decisions into the network nodes (e.g., border gateway, edge node or access node) if the resource request is authorized and admitted.
+
+### - CPE-triggered reservation:
+
+The CPE supports RSVP-like or other transport signalling (e.g., GPRS session management signalling, ATM PNPI/Q.931). It is able to directly perform transport QoS negotiation throughout the transport facilities (e.g., DSLAM, CMTS, SGSN/GGSN).
+
+In the CPE-triggered QoS resource reservation mechanism, the CPE sends a 'QoS request' over a dedicated path-coupled QoS signalling to invoke the QoS resource reservation for a given flow. Based on the 'QoS request' from the CPE, the network border node is responsible for sending the RACF a resource decision request to pull the admission control decisions from the RACF.
+
+Especially in multiple network domains, signalling among different service/network operators is additionally needed for exchanging QoS information.
+
+There are two scenarios for passing the QoS information for a given service over an end-to-end path:
+
+- 1) The QoS requirements for a given service can be passed over the end-to-end path through application layer signalling or through the Ri reference point.
+- 2) The QoS requirements for a given service can be passed over the end-to-end path through path-coupled QoS signalling (e.g., RSVP-like).
+
+Those inter-domain communications for end-to-end QoS control are based on [ITU-T Y.2111]. Appendix II describes two example scenarios.
+
+## 8.8 Ethernet traffic grooming
+
+To support the guaranteed QoS over the Ethernet, traffic grooming is required. When an access node (or an edge router) is connected to core MPLS/GMPLS nodes, it is required that the traffic grooming functionality is based on the MPLS/GMPLS traffic grooming technology for compatibility. Traffic grooming is the process of grouping Ethernet frames into virtual connections. For example, in the VPN reference model described in clause 7.3.1, PE creates groups of Ethernet frames that are transported via the same tunnel.
+
+# 9 Operation, administration and maintenance for the Ethernet-based NGN
+
+OAM functionality is important in delivering network performance and availability objectives as well as in minimizing operational costs. Offering a reliable Ethernet service that can support the requirements of a service level agreement (SLA) requires the Ethernet service to have its own OAM capabilities.
+
+The requirements for Ethernet OAM are described in [ITU-T Y.1730] and the detailed OAM functions and mechanisms for Ethernet-based networks are defined in [ITU-T Y.1731].
+
+# **10 Ethernet protection and restoration for the Ethernet-based NGN**
+
+Protection and restoration are also important to enhance network availability. As the Ethernet OAM is required, protection and restoration mechanisms at the Ethernet layer itself are also required to provide reliable Ethernet services based on SLAs. The Ethernet protection switching mechanism for the linear subnetwork connection is described in [ITU-T G.8031] and the protection switching for the ring connection is described in [ITU-T G.8032].
+
+# **11 Security consideration**
+
+Security considerations are addressed in clause 7.3 (VPN configuration) and clause 7.5 (access control). Configuring VPN and activating the appropriate filtering capabilities require the relevant authentication procedures. A VPN solution has the mechanisms to activate the appropriate access control capabilities at customer request.
+
+The detailed security requirements for VPN and access control are out of scope of this Recommendation.
+
+# Appendix I
+
+### Example of access control mechanism
+
+(This appendix does not form an integral part of this Recommendation)
+
+To access the network successfully, a supplicant takes the relevant authentication and authorization process by relying on authenticator and authentication server. Figure I.1 is an example to illustrate the relationship among the supplicant, authenticator and authentication server as well as the exchange of information among them.
+
+
+
+The diagram illustrates the roles of three main components: Supplicant, Authenticator, and Authentication Server.
+
+- Supplicant (Yellow box):** Contains a **Supplicant PAE** (Protocol Access Entity).
+- Authenticator (Light blue box):** Contains an **802.1D bridge** and an **Authenticator PAE**. It is connected to the Supplicant via a **Controlled Port** and to the Authentication Server via an **Uncontrolled Port**.
+- Authentication Server (Orange box):** Contains a **RADIUS Server**.
+
+Information flow and connections:
+
+- The **Supplicant PAE** and **Authenticator PAE** are connected via **EAPOL** (EAP over LAN) over the **LAN**.
+- The **Authenticator PAE** is connected to the **802.1D bridge** and the **Backend RADIUS client**.
+- The **Backend RADIUS client** is connected to the **RADIUS Server** via **EAP Over RADIUS**.
+- The **Authenticator** is connected to the **LAN** via a **Port of attachment**.
+
+Diagram illustrating the roles of Supplicant, Authenticator, and Authentication Server in an access control mechanism.
+
+**Authenticator:** An entity at one end of a point-to-point LAN segment that facilitates authentication of the entity attached to the other end of that link.
+
+**Authentication server:** An entity that provides an authentication service to an authenticator.
+
+**Network access port:** A point of attachment of a system to a LAN.
+
+**Port access entity (PAE):** The protocol entity associated with a port.
+
+**Supplicant:** An entity at one end of a point-to-point LAN segment that is being authenticated by an authenticator attached to the other end of that link.
+
+**System:** A device that is attached to a LAN by one or more ports.
+
+**Figure I.1 – An example to illustrate authenticator, supplicant and authentication server roles**
+
+As shown in Figure I.1, the authenticator's controlled port is in an unauthorized state and is therefore disabled from the viewpoint of access to the services offered by the authenticator's system.
+
+For the authentication protocol between the supplicant and the authentication server, EAP (extensible authentication protocol) [b-IETF RFC 2284] and [b-IETF RFC 3748] can be used. Over the LAN segment, EAP information is encapsulated in a LAN frame with the EAPoL (EAP over LAN) protocol, and delivered to the bridge. The authenticator acts as a RADIUS client for the authentication server.
+
+- In the supplicant role, the port access entity (PAE) is responsible for responding to requests from an authenticator for information that will establish its credentials. The PAE performing the supplicant role in an authentication exchange is known as the supplicant PAE.
+
+- In the authenticator role, the PAE is responsible for communication with the supplicant, and for submission of the information received from the supplicant to a suitable authentication server to enable the credentials to be checked and the consequent authorization state to be determined. The PAE performing the authenticator role in an authentication exchange is known as the authenticator PAE.
+- The authentication server performs the authentication function necessary to check the credentials of the supplicant on behalf of the authenticator and indicates whether the supplicant is authorized to access the authenticator's services.
+
+## Appendix II
+
+### Example scenarios of resource reservation procedure
+
+(This appendix does not form an integral part of this Recommendation)
+
+This appendix provides examples of inter-domain communications for QoS control. Two means of passing the QoS information for a given service over an end-to-end path are illustrated: passing the information through the Ri reference point and passing the information through path-coupled QoS signalling. Figures II.1 and II.2 provide examples. The steps identified in the figures are described in the text below them.
+
+
+
+```
+sequenceDiagram
+ participant CPE_X as CPE X
+ participant TN_A as Transport Network A
+(AN/EN/ABG/IBG-FE)
+ participant RACF_A as RACF A
+ participant RACF_B as RACF B
+ participant TN_B as Transport Network B
+(AN/EN/ABG/IBG-FE)
+ participant CPE_Y as CPE Y
+
+ Note over CPE_X, TN_A: Path-coupled QoS signalling
+ Note over TN_A: 1. Trigger
+ TN_A->>RACF_A: 2. Resource decision request
+ Note over RACF_A: 3. Admission control
+ RACF_A->>RACF_B: 4. Resource decision request
+ Note over RACF_B: 5. Admission control
+ RACF_B->>TN_B: 6. Resource initiation request
+ TN_B->>RACF_B: 7. Resource initiation response
+ RACF_B->>RACF_A: 8. Resource decision response
+ RACF_A->>TN_A: 9. Resource decision response
+ Note over CPE_X, TN_A: Path-coupled QoS signalling
+ Note over TN_B, CPE_Y: Path-coupled QoS signalling
+```
+
+Sequence diagram illustrating inter-domain communications for QoS control through the Ri reference point between CPE X, Transport Network A, RACF A, RACF B, Transport Network B, and CPE Y.
+
+**Figure II.1 – Example of inter-domain communications for QoS control through Ri reference point**
+
+Steps 1-3 in Figure II.1 correspond to the CPE-request QoS resource reservation procedure defined in [ITU-T Y.2111].
+
+- 4) If it needs an additional admission decision from another RACF domain, an RDR (resource decision request) is triggered by RACF A, QoS requirements for the requested service are passed through Ri reference point.
+- 5) On receipt of the RDR from RACF A, RACF B makes an admission decision. The decision procedures correspond to the SCF-requested QoS reservation procedure defined in [ITU-T Y.2111].
+- 6) RACF B sends a RIR (resource initiation request) to install the final admission decisions in the transport network B. The RIR from RACF B requests the admission decisions to be enforced immediately (i.e., RIR (reservation + commitment)).
+
+- 7) Transport network B installs (and enforces) the admission decisions sent from the RACF B and sends a RIP (resource initiation response) back to the RACF B. After sending RIP, a resource reservation indication message is transferred to CPE Y through path-coupled QoS signalling.
+- 8-9) RACF B and RACF A send RDRs (resource decision response) back to the requester.
+
+
+
+```
+
+sequenceDiagram
+ participant CPE_X as CPE X
+ participant TN_A as Transport Network A
+(AN/EN/ABG/IBG-FE)
+ participant RACF_A as RACF A
+ participant RACF_B as RACF B
+ participant TN_B as Transport Network B
+(AN/EN/ABG/IBG-FE)
+ participant CPE_Y as CPE Y
+
+ Note over CPE_X, TN_A: 1. Trigger
+ TN_A->>RACF_A: 2. Resource decision request
+ Note over RACF_A: 3. Admission control
+ RACF_A->>TN_A: 4. Resource decision response
+ TN_A->>TN_B: 5. Path-coupled QoS signalling
+ Note over TN_B, CPE_Y: 6. Trigger
+ TN_B->>RACF_B: 7. Resource decision request
+ Note over RACF_B: 8. Admission control
+ RACF_B->>TN_B: 9. Resource decision response
+ TN_B->>TN_A: 10. Path-coupled QoS signalling
+ TN_A->>CPE_X: Path-coupled QoS signalling
+
+```
+
+The diagram illustrates the sequence of events for QoS control across two transport networks. It involves six entities: CPE X, Transport Network A (AN/EN/ABG/IBG-FE), RACF A, RACF B, Transport Network B (AN/EN/ABG/IBG-FE), and CPE Y. The process begins with a 'Trigger' at CPE X, which sends a 'Resource decision request' to RACF A in Transport Network A. RACF A performs 'Admission control' and returns a 'Resource decision response'. Transport Network A then sends 'Path-coupled QoS signalling' to Transport Network B. A second 'Trigger' occurs at CPE Y, leading Transport Network B to send a 'Resource decision request' to RACF B. RACF B performs 'Admission control' and returns a 'Resource decision response'. Transport Network B then sends 'Path-coupled QoS signalling' back to Transport Network A, which finally relays it to CPE X.
+
+Sequence diagram showing inter-domain communications for QoS control through path-coupled QoS signalling between CPE X, Transport Network A, RACF A, RACF B, Transport Network B, and CPE Y.
+
+**Figure II.2 – Example of inter-domain communications for QoS control through path-coupled QoS signalling**
+
+Steps 1-4 in Figure II.2 correspond to the CPE-request QoS resource reservation procedure defined in [ITU-T Y.2111].
+
+- 5) Transport network A and transport network B exchange QoS requirements through path-coupled QoS signalling. An RDR is triggered by a request indicated through the QoS signalling from transport network A. RACFs of each network domain work independently.
+
+Steps 6-9 in Figure II.2 correspond to the CPE-request QoS resource reservation procedure defined in [ITU-T Y.2111] with the exception of the resource reservation indication message transferred to CPE Y through path-coupled QoS signalling.
+
+- 10) Transport network A and transport network B exchange the result of resource reservation through path-coupled QoS signalling. This result of resource reservation is further transferred to CPE X through path-coupled QoS signalling.
+
+# Bibliography
+
+- [b-IETF RFC 2284] IETF RFC 2284 (1998), *PPP Extensible Authentication Protocol (EAP)*.
+- [b-IETF RFC 2917] IETF RFC 2917 (2000), *A core MPLS IP VPN architecture*.
+- [b-IETF RFC 3031] IETF RFC 3031 (2001), *Multiprotocol Label Switching Architecture*.
+- [b-IETF RFC 3312] IETF RFC 3312 (2002), *Integration of Resource Management and Session Initiation Protocol (SIP)*.
+- [b-IETF RFC 3353] IETF RFC 3353 (2002), *Overview of IP Multicast in a Multi-Protocol Label Switching (MPLS) environment*.
+- [b-IETF RFC 3748] IETF RFC 3748 (2004), *Extensible Authentication Protocol (EAP)*.
+- [b-IETF RFC 4566] IETF RFC 4566 (2006), *SDP: Session Description Protocol*.
+- [b-IETF RFC 4664] IETF RFC 4664 (2006), *Framework for Layer 2 Virtual Private Networks (L2VPNs)*.
+- [b-IETF RFC 4665] IETF RFC 4665 (2006), *Service Requirements for Layer 2 Provider-Provisioned Virtual Private Networks*.
+- [b-IETF RFC 4761] IETF RFC 4761 (2007), *Virtual Private LAN Service (VPLS) using BGP for Auto-Discovery and Signaling*.
+- [b-IETF RFC 4762] IETF RFC 4762 (2007), *Virtual Private LAN Service (VPLS) using Label Distribution Protocol (LDP) signaling*.
+- [b-IEEE 802.1ad] IEEE Standard 802.1ad (2005), IEEE Standard for Local and metropolitan area networks – *Virtual Bridged Local Area Networks – Amendment 4: Provider Bridges*.
+- [b-IEEE 802.1ah] IEEE Standard 802.1ah (2008), IEEE Standard for Local and metropolitan area networks – *Virtual Bridged Local Area Networks – Amendment 6: Provider Backbone Bridges*.
+- [b-IEEE 802.1D] IEEE Standard 802.1D (1998), IEEE Standard for Local and metropolitan area networks – *Media Access Control (MAC) Bridges*.
+- [b-IEEE 802.1S] IEEE Standard 802.1S (2002), Amendment 3: IEEE Standard for Local and metropolitan area networks – *Multiple Spanning Trees*.
+- [b-IEEE 802.1X] IEEE Standard 802.1X (2001), IEEE Standard for Local and metropolitan area networks – *Port-based network access control*.
+- [b-IEEE 802.3] IEEE Standard 802.3 (2005), *Information technology – Local and metropolitan area networks – Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications*.
+- [b-MEF6] *Technical Specification MEF 6 (2004), Ethernet Services Definition Phase I*.
+- [b-MEF10.1] *Technical Specification MEF 10.1 (2006), Ethernet Services Attributes Phase 2*.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fcb45d837967ed408d0b8f93cfe1b069c6ee324c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f38213a509578520744cb6aba639b9d80e3724a634cb23515a9f99ebd6744355
+size 29041
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/3121ebddccf183ca63bb9781be440a7e_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/3121ebddccf183ca63bb9781be440a7e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..89faf4baf9cbeacb51a3adb9fae2ed78642c777b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/3121ebddccf183ca63bb9781be440a7e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e02146f1d0ebf5e79a69af5f19e349912fa38a335d406bcda332105e230078da
+size 142842
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..841f5a94b59ae2231af2d2220d29465e2b424a38
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ac0b42c47d1057713fa1ff8179d0c16edac90d7edc096bdcdc2c2aa67c7baddb
+size 62373
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/49ee89a1d5852ab005dbbab6de09a8a6_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/49ee89a1d5852ab005dbbab6de09a8a6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..06f20b49ec48ecaebedd1381e68df850c57c6538
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/49ee89a1d5852ab005dbbab6de09a8a6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2f40d30e5d45f2be5fa837aeaa8121f633bb73f69fd39860f7a020a1949d9e61
+size 27570
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..30b08466f7a9a85b405a37f8f151c69ae42bd15b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2fca288f5d76aa8b169630a1f76fd4b21f905b4fcbef0d162b352e557fec492b
+size 93339
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..72992eeed934e31d7131e4cfdb68179482a559a9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:193a2edca46ade04028d50f3b66f82526f6b0725052c77b27c34c955598b2433
+size 19246
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/9ee1a10ae91d4878e24b2e7dbaa95c2e_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/9ee1a10ae91d4878e24b2e7dbaa95c2e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6f7e5b2d98847f267e3eb9c4d28fc50da7819b99
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/9ee1a10ae91d4878e24b2e7dbaa95c2e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9b2b15785fea3a73d4d9866fd44f00b00b6fdeae8b1726b42b6db933bf29a508
+size 17773
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..36cf51f8ba07e44aa7a4b009f3ba08eb2b570b1c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11780faeee75ba39ab4ed9de67a9e67abec0d9ba3068ebec661dea70c16e29d3
+size 4338
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8adf8e9b5c459c45162208dfb5be51658705359c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:416596a567162a798c6ac4deb568b9824ef685974b03414459b44ce292e813ea
+size 27478
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0278962960ab8e7bc7c42e3b27810a5444467ba2
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:895d02ac61489937b3e287a8a804dadec21054bff8919763794ddfae760e377b
+size 21315
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..05a1d4fd0710883b5dc6011a04a7c191948f1ae7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9e8e8fbe5e70749d549931de32ea30545f192df93dcc42e476b389aa792f22d1
+size 28241
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/e9b43ac020435f8121e8592f31afdc52_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/e9b43ac020435f8121e8592f31afdc52_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bee08be081d8dd2adc7de242a81ce850ceda7399
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/e9b43ac020435f8121e8592f31afdc52_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:54f318635e9e4195de6db4ac8b3cbc3da3b750d52842a84322ed2b2edf036eff
+size 23003
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ead623e6a8ec701df64567695a57d01c_img.jpg b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ead623e6a8ec701df64567695a57d01c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bb7ee6e041b33805eaccabde6127bfc36acc30a7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/ead623e6a8ec701df64567695a57d01c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0b6ccbb1b57d78f826e1b12cc878b398161e84b9fcd3c969687c9aa20895dea0
+size 13969
diff --git a/marked/Y/T-REC-Y.2122-200906-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..f4f85c3e1097534815c79d7d7a1267327296836a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2122-200906-I_PDF-E/raw.md
@@ -0,0 +1,1055 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.2122
+
+(06/2009)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Quality of Service and
+performance
+
+# --- **Flow aggregate information exchange functions in NGN**
+
+Recommendation ITU-T Y.2122
+
+## ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Future networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## **Recommendation ITU-T Y.2122**
+
+# **Flow aggregate information exchange functions in NGN**
+
+## **Summary**
+
+Recommendation ITU-T Y.2122 specifies the requirements and architecture for flow aggregate information exchange functions (FIXF). FIXF allows network domains to exchange flow aggregate information that reflects the current network conditions. In order to guarantee end-to-end QoS in NGN, cooperation among networks in an end-to-end path is necessary. Exchange of network configuration information is a key component of cooperation among participating networks. Flow aggregation has been considered a scalable technique for traffic management. Additional information obtained through FIXF can improve the accuracy of performance estimation and effectiveness of resource management.
+
+### **Source**
+
+Recommendation ITU-T Y.2122 was approved on 29 June 2009 by ITU-T Study Group 13 (2009-2012) under Recommendation ITU-T A.8 procedures.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+### INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2010
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## CONTENTS
+
+| | Page |
+|-------------------------------------------------------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 High level requirements for FA information exchange functions ..... | 3 |
+| 7 Information exchange architecture ..... | 3 |
+| 7.1 Overall architecture ..... | 3 |
+| 7.2 Modes of operation..... | 4 |
+| 7.3 Operation of FA information exchange functions..... | 6 |
+| 7.4 Functional entities ..... | 7 |
+| 7.5 Reference points ..... | 9 |
+| 8 Information to be exchanged ..... | 9 |
+| 8.1 Parameters not specific to a FA..... | 9 |
+| 8.2 FA parameters ..... | 10 |
+| 8.3 Parameters exchanged at the reference points..... | 12 |
+| 9 Security considerations..... | 12 |
+| Appendix I – Typical network topology for FA parameter exchange ..... | 14 |
+| Appendix II – A usage example – Admission decision process ..... | 15 |
+| II.1 DiffServ expedited forwarding..... | 16 |
+| II.2 IntServ guaranteed rate service ..... | 16 |
+| II.3 Networks with various granularity flow aggregation (MPLS, FSA in [b-ITU-T Y.2121], etc.)..... | 17 |
+| II.4 Calculation of the burst-in or equivalently the burst-out..... | 17 |
+| Appendix III – A usage example – Flow granularity and continuity decision process ..... | 19 |
+| III.1 FA granularity and continuity decision process ..... | 19 |
+| Appendix IV – FIM-FE usage scenarios..... | 20 |
+| IV.1 FA table entry writing ..... | 20 |
+| IV.2 Information management mechanism for multiple ARs in a single network ..... | 20 |
+| IV.3 Information management mechanism for a single AR over multiple networks ..... | 20 |
+| Appendix V – FIE-FE usage scenarios ..... | 21 |
+| V.1 Cases of information exchange for multiple-ARs in a network ..... | 21 |
+| V.2 Cases of information exchange for a single AR in multiple networks..... | 21 |
+| Appendix VI – Example allocation of FA parameter values ..... | 22 |
+| VI.1 Mapping rule from flow ID to FA ID..... | 22 |
+| VI.2 Bandwidth allocation enforcement method or scheduling method ..... | 22 |
+
+| | Page |
+|------------------------------------------------------------------------------------------------------------|-------------|
+| VI.3 Representative (R) ..... | 22 |
+| VI.4 FA identifier ..... | 22 |
+| VI.5 Number of flows within the FA..... | 23 |
+| VI.6 Maximum packet length divided by link capacity ..... | 23 |
+| VI.7 Number of hops within the aggregation region or the policy region ..... | 23 |
+| VI.8 Maximum number of aggregation regions ..... | 23 |
+| VI.9 Maximum sum of sustainable transfer rates (Rs) divided by link capacity ... | 23 |
+| VI.10 Maximum sum of sustainable burst sizes (Bs) divided by link capacity ..... | 23 |
+| VI.11 Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority ..... | 24 |
+| VI.12 Packet discard priority ..... | 24 |
+| VI.13 Class (service context)..... | 24 |
+| VI.14 Summary..... | 24 |
+| Appendix VII – Network specific parameter values..... | 25 |
+| VII.1 DiffServ network specific parameters ..... | 25 |
+| VII.2 DiffServ with traffic engineering (TE) network specific parameters..... | 25 |
+| VII.3 Flow state aware (FSA) network specific parameters ..... | 26 |
+| Bibliography..... | 28 |
+
+# Introduction
+
+This Recommendation specifies the requirements and architecture for flow aggregate information exchange functions (FIXF). It addresses the flow or flow aggregate (FA) performance prediction by way of exchanging the network operating parameters or unique parameters of flow aggregates. There are a few critical parameters (e.g., number of hops, link capacity, etc.) for the performance of a flow for a given QoS architecture, which are sometimes tuned dynamically (from time-to-time, from flow-to-flow) within a network. By having the other networks' parameters for the flow (or for the flow aggregate to which the flow belongs), one can infer the performance of the flow in these networks and in its own network. The estimation can be complemented by measurement, i.e., the estimation rules can be further adjusted by the measured performances. Consider the following example: A delay bound for an expedited forwarding (EF) flow in a differentiated services (DiffServ) network can be calculated by using parameters given from neighbouring networks. The initial delay estimation rule can be just to adopt the delay bound obtained from the calculation. The bound, however, can be too conservative, compared to the measured delay, especially when the maximum burst sizes of flows in the same class are large. Then one can adjust the estimation rule to reduce the expected delay value under condition that the maximum burst sizes are large.
+
+One obvious benefit of this approach is that upon a flow admission request, network operators can immediately decide whether the requested end-to-end performances can be met, based on the estimation rules that have been adjusted and stabilized. The frequency of the exchange, estimation, comparison, and adjustment can vary according to implementation. The frequency of exchange for a given flow aggregate, for example, depends on the parameter value precision, flow granularity, intended level of accuracy, etc.
+
+The overall process for the performance estimation is depicted in Figure Intro.1.
+
+
+
+```
+graph LR; Exchange[Exchange parameters] --> Decide[Decide estimation rules]; Decide --> Estimate[Estimate performances]; Estimate --> Compare[Compare]; Measure[Measure performances] --> Compare; Compare --> Adjust[Adjust rules]; Adjust --> Decide; Scope[Scope of the Recommendation] -.-> Exchange;
+```
+
+The diagram illustrates a feedback loop for performance estimation. It starts with 'Exchange parameters', which leads to 'Decide estimation rules'. From 'Decide estimation rules', the process moves to 'Estimate performances'. 'Estimate performances' then leads to 'Compare'. 'Measure performances' also feeds into 'Compare'. From 'Compare', the process moves to 'Adjust rules', which then feeds back into 'Decide estimation rules'. A dashed line from 'Scope of the Recommendation' points to the 'Exchange parameters' box. The identifier 'Y.2122(09)\_FIntro-1' is located at the bottom right of the diagram.
+
+Flowchart of the estimation process example based on exchanged parameters.
+
+**Figure Intro.1 – Estimation process example based on exchanged parameters**
+
+The network operating parameters to be exchanged vary according to network QoS architecture. For example, in the DiffServ [b-IETF RFC 2475] architecture (or 802.1Q, 802.11e-type networks) the important parameters include the behaviour aggregate (BA) to which a packet belongs, and the bandwidth utilization of the BA based on the implied admission policy (e.g., not more than 10% for EF BA). In another example, the flow aggregation granularity and the number of hops in an aggregation region, in case of a flow-based network such as flow state aware network [b-ITU-T Y.2121], are the important parameters.
+
+![Figure Intro.2 – Position of the FA information exchange functions in the NGN architecture [ITU-T Y.2012]. The diagram shows the NGN architecture layers: Applications, Service stratum, Transport stratum, and Transport functions. The FA information exchange functions (FIXF) are located within the Management functions block, which is connected to the End-user functions and Other networks blocks. The diagram also shows the UNI and NNI interfaces and the ANI interface.](3121ebddccf183ca63bb9781be440a7e_img.jpg)
+
+The diagram illustrates the NGN architecture layers and their interactions. At the top is the **Applications** layer, connected to the **Service stratum** layer via the **ANI** (Application Network Interface). The **Service stratum** layer contains **Application support functions and service support functions** and **Service control functions**, which include **Service user profiles**. Below the Service stratum is the **Transport stratum** layer, which contains **Network attachment control functions** (including **Transport user profiles**) and **Resource and admission control functions**. These are collectively labeled as **Transport control functions**. The bottom layer is **Transport functions**. The **Management functions** block is shown on the left, containing the **FA information exchange functions (FIXF)**. This block is connected to the **End-user functions** and **Other networks** blocks via **UNI** (User Network Interface) and **NNI** (Network Network Interface) respectively. The diagram also shows the **Media** flow between the End-user functions and Other networks blocks. The legend indicates that dashed lines represent **Control**, hatched lines represent **Media**, and dotted lines represent **Management**.
+
+Figure Intro.2 – Position of the FA information exchange functions in the NGN architecture [ITU-T Y.2012]. The diagram shows the NGN architecture layers: Applications, Service stratum, Transport stratum, and Transport functions. The FA information exchange functions (FIXF) are located within the Management functions block, which is connected to the End-user functions and Other networks blocks. The diagram also shows the UNI and NNI interfaces and the ANI interface.
+
+**Figure Intro.2 – Position of the FA information exchange functions in the NGN architecture [ITU-T Y.2012]**
+
+As depicted in Figure Intro.2, the FA information exchange functions defined in this Recommendation are one of the NGN management functions. The goal of the functions is to provide additional information to improve the accuracy of the admission decision. The FIXF collects the FA configuration information throughout the networks. The collected information can be used for estimating the end-to-end QoS, thus possible applications of this function can be the resource and admission control functions (RACF) or other management functions that handle end-to-end QoS.
+
+## Recommendation ITU-T Y.2122
+
+# Flow aggregate information exchange functions in NGN
+
+# 1 Scope
+
+This Recommendation defines the network operating parameters of a flow aggregate (FA) to be exchanged among different network domains for various types of FAs in NGN, and defines the architecture for exchanging these parameters. It also defines, for informational purposes, the mapping of the transport technology specific parameters to the defined network operating parameters. The details of the protocols are for further study and are out of the scope of this Recommendation. Usage examples of the exchanged operating parameters are shown in several appendices.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T Y.2012] Recommendation ITU-T Y.2012 (2006), *Functional requirements and architecture of the NGN release 1*.
+
+[ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1*.
+
+# 3 Definitions
+
+This Recommendation defines the following terms:
+
+**3.1 aggregation end point:** The node where a flow aggregate is de-aggregated. Aggregate start and end points for a flow aggregate can collocate in the same node.
+
+**3.2 aggregation region:** A set of neighbouring nodes within which every flow maintains its membership of a flow aggregate unaltered. For example, in a DiffServ network, the aggregation region is usually limited to a single node, since at the very next node the membership within a behaviour aggregate is likely to be changed. An aggregation region is defined per flow aggregate. Typically, a node can belong to multiple aggregation regions at the same time.
+
+**3.3 aggregation start point:** The node where flows are aggregated to form a flow aggregate.
+
+**3.4 flow:** A set of IP packets that have the same IP 5-tuple in case of IPv4 packets, or have the same flow label in case of IPv6 packets.
+
+**3.5 flow aggregate:** A set of flows treated in the same way in terms of scheduling.
+
+**3.6 flow aggregate membership:** The flows within the flow aggregate. The membership can be identified by the set of flow IDs within the flow aggregate. A given flow at a given node cannot be a member of different flow aggregates at the same time.
+
+**3.7 flow aggregate table:** A set of flow aggregate table entries.
+
+**3.8 flow aggregate table entry:** A set of information for a flow aggregate including flow aggregate specific configuration parameters. A flow aggregate table entry is the elementary unit to be maintained and exchanged.
+
+**3.9 number of hops:** The number of nodes in an aggregation region, including both aggregation start point and aggregation end point.
+
+**3.10 policy region:** A set of neighbouring nodes within which a single policy regarding the flow aggregation is applied. In this Recommendation, it is assumed that an administrative domain is a single policy region. A "network" or a "domain" means a policy region.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|----------|-----------------------------------------------|
+| AEP | Aggregation End Point |
+| AR | Aggregation Region |
+| ASP | Aggregation Start Point |
+| BC | Bandwidth Constraint |
+| Bs | Sustainable Burst Size |
+| CT | Class Type |
+| DiffServ | Differentiated Services |
+| DSCP | DiffServ Code Point |
+| DS-MPLS | DiffServ over MPLS |
+| ECN | Explicit Congestion Notification |
+| FA | Flow Aggregate |
+| FIE-FE | FA Information Exchange functional entity |
+| FIG-FE | FA Information Gathering functional entity |
+| FIM-FE | FA Information Management functional entity |
+| FIXF | Flow Aggregate Information Exchange Functions |
+| FSA | Flow State Aware |
+| IntServ | Integrated Services |
+| LSB | Least Significant Bit |
+| LSP | Label Switched Path |
+| MAM | Maximum Allocation Model |
+| MSB | Most Significant Bit |
+| PHB | Per Hop Behaviour |
+| R | Representative |
+| RACF | Resource and Admission Control Functions |
+| RDM | Russian Dolls Model |
+| Rs | Sustainable Transfer Rate |
+| TE | Traffic Engineering |
+| WFQ | Weighted Fair Queuing |
+
+# **5 Conventions**
+
+None.
+
+# **6 High level requirements for FA information exchange functions**
+
+The FA information exchange functions described in this Recommendation are required to:
+
+- 1) be able to gather information on flow aggregates configuration parameters from networks, which are physically separated and are willing to exchange their information;
+- 2) be able to provide gathered information to application entities which can utilize the global FA information to facilitate end-to-end QoS;
+- 3) have minimum impact on the performance of the underlying transport layer; and
+- 4) be flexible in updating, exchanging, and gathering transaction's frequencies and triggering methods.
+
+# **7 Information exchange architecture**
+
+This clause provides:
+
+- a description of functional entities of the FA information exchange functions; and
+- a description of modes of the FA information exchange functions required to establish the management view of a complete end-to-end customer service and the hierarchy of management information flows required to provide and maintain such a service.
+
+It should be noted that the modes of information exchange presented here are lists of reasonable approaches to meet the requirements for orderly provision of end-to-end QoS services which should allow operators to cooperate; or an operator maintaining multiple domains to cooperate among domains, in support of this. More modes of operation can further be defined.
+
+## **7.1 Overall architecture**
+
+Figure 7-1 describes the functional architecture of FA information exchange with the functional entities. (For a detailed description of the functional entities, see clause 7.4). This architecture includes:
+
+- FIM-FE (FA information management functional entity): FIM-FE is responsible for maintaining and updating the information on a per-flow aggregate basis. This information is captured in a form of a flow aggregate table.
+- FIE-FE (FA information exchange functional entity): FIE-FE is responsible for providing the FA table to the FIG-FE.
+- FIG-FE (FA information gathering functional entity): FIG-FE is the final point of the information gathering and processing. FIG-FE is responsible for handling requests from applications it is associated with.
+
+
+
+Figure 7-1: Functional architecture for FA information exchange. The diagram shows a hierarchical structure. At the top is a box labeled 'FIXF application'. Below it is an oval labeled 'FIG-FE'. A vertical line labeled 'Fu' connects them. From 'FIG-FE', two lines labeled 'Fa' branch out to two ovals labeled 'FIE-FE'. Each 'FIE-FE' oval has a self-loop arrow labeled 'Fc'. A horizontal line labeled 'Fb' connects the two 'FIE-FE' ovals. Below each 'FIE-FE' oval is an oval labeled 'FIM-FE', connected by a vertical line labeled 'Fd'. The label 'Y.2122(09)\_F7-1' is at the bottom center.
+
+**Figure 7-1 – Functional architecture for FA information exchange**
+
+## 7.2 Modes of operation
+
+The management of operations for information exchange, collecting and processing over multiple network domains is a challenging issue. Recently, the exchange procedures for the QoS measurement information over networks have been standardized both in ITU-T [b-ITU-T Y.2173] and IETF [b-IETF RFC 5470]. This clause defines the operation modes for generic flow aggregate information exchange based on the distributed models such as specified in [b-ITU-T Y.2173]. A network participating in flow aggregate information exchange functions is required to support the following modes of operations.
+
+#### 7.2.1 Hub mode
+
+In Hub mode, it is assumed that a central entity exists for cooperation among networks in the end-to-end path. The central entity governs all the transactions (information exchanges) among networks. Note that this does not imply there should only be one central entity over Internet.
+
+
+
+Figure 7-2: Hub mode operation. The diagram shows a 'Central entity' box at the top containing a 'FIG-FE' oval. Below it are two 'Network' boxes. Each 'Network' box contains an 'FIE-FE' oval and an 'FIM-FE' oval. Lines connect the 'FIG-FE' oval to each 'FIE-FE' oval. To the right of the 'Network' boxes is a box labeled 'Other networks' with a line connecting it to the 'FIG-FE' oval. The label 'Y.2122(09)\_F7-2' is at the bottom right.
+
+**Figure 7-2 – Hub mode operation**
+
+#### 7.2.2 Star mode
+
+In Star mode, the central entity described in Hub mode is distributed to edge networks, usually in the ingress edge networks (by an edge network it is meant a network that directly interfaces to an access network or CPN). The central entity communicates with downstream or upstream networks. One of the most obvious advantages of the Star mode over the hub mode is its scalability.
+
+
+
+Figure 7-3: Star mode operation diagram. It shows two network boxes. The left box is labeled 'Edge network' and contains a hierarchy: FIG-FE at the top, connected to FIE-FE, which is connected to FIM-FE and FE. The right box is labeled 'Network' and contains a hierarchy: FIE-FE at the top, connected to FIM-FE and FE. A line connects the FIG-FE in the 'Edge network' box to the FIE-FE in the 'Network' box. To the right of these boxes is a large box labeled 'Other networks'. The identifier 'Y.2122(09)\_F7-3' is at the bottom right.
+
+**Figure 7-3 – Star mode operation**
+
+#### 7.2.3 Cascade mode
+
+Cascade mode can be seen as a peer-to-peer mode. Networks exchange information with only directly neighbouring networks.
+
+It is expected that the use of the Star and the Hub modes when there are many interconnecting network domains would be increasingly difficult to manage and vulnerable to configuration delays or errors. Smaller operators would have to offer exchange services and for them the use of the Star or Hub mode would be inappropriate in many instances. Such operators would probably consider using the Cascade mode, depicted below. Use of the Star or Hub mode requires contractual agreements between the service providers and each network domain. In summary, the use of a single point of contact for the customer, as in the Hub or Star mode and a single point of management control for the service instance is an attractive feature of these modes. By contrast, use of the Cascade mode makes it possible to build exchange services on a global basis while only maintaining contractual relationships with adjacent domains. Thus, the mode is more scalable than the Star and Hub modes and may be more appropriate for use by 'non-global' operators.
+
+A limitation of the Cascade mode is that it gives the service initiator less management control of the whole IP service path. However, with a well designed interface between operators, the service initiator will have as much information and control of the end-to-end service as the Star and Hub modes give.
+
+
+
+Figure 7-4: Cascade mode operation diagram. It shows two identical network boxes side-by-side. Each box contains a hierarchy: FIG-FE at the top, connected to FIE-FE, which is connected to FIM-FE and FE. A horizontal line connects the FIE-FE of the left box to the FIE-FE of the right box. To the right of these boxes is a large box labeled 'Other networks'. The identifier 'Y.2122(09)\_F7-4' is at the bottom right.
+
+**Figure 7-4 – Cascade mode operation**
+
+#### 7.2.4 Hybrid mode
+
+Any combination of hub, Star, and Cascade modes can be considered as Hybrid mode.
+
+## 7.3 Operation of FA information exchange functions
+
+This clause explains the procedure of the FA information collection. A typical network topology including physical locations of the functional entities is described in Appendix I. The following information components are exchanged over the reference points:
+
+- Requestor identifier: a unique identifier for the sender of the request message.
+- Responder identifier: a unique identifier for the sender of the response message.
+- Reporter identifier: a unique identifier for the sender of the report message.
+- FA identifier: a unique identifier for a FA (e.g., MPLS LSP).
+- FA parameters: the list of FA parameters specified in Table 2.
+
+Table 1 summarizes the exchanged messages and associated information components.
+
+**Table 1 – Messages for the FA parameter exchange**
+
+| Exchanged message | Information components | Reference points | Direction |
+|-------------------------|---------------------------|------------------|------------------|
+| FA-information-request | Requestor identifier | Fa | FIG-FE to FIE-FE |
+| | FA identifiers (optional) | Fb and Fc | FIE-FE to FIE-FE |
+| | | Fd | FIE-FE to FIM-FE |
+| FA-information-response | Responder identifier | Fa | FIE-FE to FIG-FE |
+| | FA identifiers (optional) | Fb and Fc | FIE-FE to FIE-FE |
+| | FA parameters | Fd | FIM-FE to FIE-FE |
+| FA-information-report | Reporter identifier | Fa | FIE-FE to FIG-FE |
+| | FA identifiers (optional) | Fb and Fc | FIE-FE to FIE-FE |
+| | FA parameters | Fd | FIM-FE to FIE-FE |
+
+The operation of the FA information collection is performed either by request or report. FA-information-request and FA-information-response are used in the request model, and FA-information-report message is used in the report model. The FEs form three levels of hierarchy. In the request model, the higher level FE requests the FA information to the lower level FE. In the report model, the lower level FE sends the FA configuration changes to the higher level FE.
+
+The request operation is initiated by FIG-FE. The request operation does not require the real-time level dynamics. The response time of the request can be several seconds. The information collection occurs periodically or on an on-demand basis. In a periodical request operation, the polling interval can vary according to the dynamics of the network. In the normal case, it can be in the order of several minutes. Figure 7-5 shows the FA request procedure. The FIG-FE polls the FIE-FE for the FA information of the domain. The FIE-FE, then sends the response to the requester FIG-FE with the updated FA information of domain. When a domain contains multiple aggregation regions, one FIE-FE represents the domain and provides the domain information to the FIG-FE. FIE-FEs other than the representing FIE-FE exchange the information through the representing FIE-FE. If the FA information of FIE-FE is not the latest one, FIE-FE may send the FA-information-request to the FIM-FE to collect the latest information. It is recommended that the polling response contain the FA parameters of all the FAs under the responder's control. It is optional that the requestor specify the FA identifier to collect the FA parameter of the specified FA.
+
+
+
+Sequence diagram for Figure 7-5: Procedure for the request operation for FA information. The diagram shows the interaction between FIG-FE, FIE-FE, and FIM-FE across two aggregation regions. In Aggregation region 1, FIG-FE sends an FA\_Info\_Request to FIE-FE, which then forwards it to FIM-FE. FIM-FE sends an FA\_Info\_Response back to FIE-FE, which forwards it to FIG-FE. In Aggregation region 2, FIE-FE sends an FA\_Info\_Request to FIM-FE, which sends an FA\_Info\_Response back to FIE-FE, which then forwards it to FIG-FE. The diagram is labeled Y.2122(09)\_F7-5.
+
+**Figure 7-5 – Procedure for the request operation for FA information**
+
+In the report operation, the report is sent from the lower level FE to the higher level FE. The report can be sent periodically or whenever the FA configuration is changed. It is recommended that the FIM-FE send a report when the local FA information is changed. Figure 7-6 shows the procedure of FA information exchange in the report model. FIM-FE sends the report to FIE-FE whenever the local FA configuration is changed. Once FIE-FE receives the information from the FIM-FE, the FIE-FE composites the received information and sends the domain level report to FIG-FE. If the configuration change is significant, FIE-FE can send the report to FIG-FE immediately after receiving a report from FIM-FE. Otherwise, FIE-FE stores the updated FA information and sends it at the next reporting period.
+
+
+
+Sequence diagram for Figure 7-6: Procedure for the report operation for FA information update. The diagram shows FIM-FE sending an FA\_Info\_Report to FIE-FE, which then sends an FA\_Info\_Report to FIG-FE. The diagram is labeled Y.2122(09)\_F7-6.
+
+**Figure 7-6 – Procedure for the report operation for FA information update**
+
+In real implementations, the request and report models are all used together. For example, the reference point Fd between FIE-FE and FIM-FE may work in the report model while Fa between FIE-FE and FIG-FE works in the request model. In this case, the FIE-FE receives the FA parameters whenever the configuration change occurs in FIM-FE. The updated FA information is collected by FIG-FE periodically.
+
+## 7.4 Functional entities
+
+#### 7.4.1 FA information management functional entity (FIM-FE)
+
+FIM-FE is specific to transport technology (e.g., MPLS). FIM-FE is responsible for maintaining and updating the information on a per-flow aggregate basis, by which the scheduling and queuing are done in a network. This information is captured in a form of flow aggregate table. Ensuring the scalability is the key reason for per-FA basis handling of information. It is required to have at least one FIM-FE in an aggregation region. Multiple aggregation regions may share a single FIM-FE, for example if they share a node with the co-located FIM-FE. FIM-FE resides optionally in either ASP
+
+(aggregation start point) or AEP (aggregation end point). Example use cases are described in Appendix IV. Typically, there are multiple FIM-FEs within a network, for example, one per each ASP. Note that many flow aggregates share an ASP (or an AEP). An FIM-FE is recommended to manage those FAs. FIM-FE is required to provide the following functions:
+
+- FA parameters mapping: FIM-FE maps the transport-technology specific FA parameters and network operation parameters into the parameters defined in this Recommendation.
+- FA table entry creation: Upon a flow admission, FIM-FE creates and populates an entry in the FA table if the flow does not belong to any existing FA. The specific mechanism for obtaining values of the entry is out of the scope of this Recommendation.
+- FA table update: Upon an event such as a flow admission, a flow release, or a flow resource modification, FIM-FE updates the corresponding FA table entry. Not every event is required to trigger an update.
+- FA table entry deletion: Upon a last flow release, FIM-FE deletes the corresponding entry from the FA table.
+- FA table content delivery: Upon request from FIE-FE, the requested part of the FA table is read and sent to FIE-FE.
+- FA table status report: Optionally, FIM-FE may trigger an interruption to notify that the FA table is updated, deleted, or created.
+
+In order to be able to create and update the FA table entry, FIM-FE is required to be able to gather the necessary information from appropriate sources, including the policy server, edge switches, or other transport stratum entities.
+
+#### **7.4.2 FA information exchange functional entity (FIE-FE)**
+
+FIE-FE is responsible for providing the FA table to FIG-FE. The request from FIG-FE can be either dynamic or subscription-based. FIE-FE is required to be able to support both cases. In the dynamic case, FIE-FE sends FA table to FIG-FE upon receiving request from FIG-FE. In the subscription-based case, FIE-FE sends the FA table to FIG-FE upon receiving the update from FIM-FE.
+
+In order to respond to the request from FIG-FE, FIE-FE is required to be able to locate the sources of information, collect information from associated FIM-FEs or other FIE-FEs of different networks or of different aggregation regions, and deliver information to the requesting FIG-FE.
+
+In order to process the report from FIM-FE, FIE-FE is required to be able to locate the destinations of the information, and deliver information to FIG-FEs or other FIE-FEs of different networks or of different aggregation regions; and deliver information to the subscribing FIG-FE.
+
+FIE-FE is required to be able to exchange information on a per-flow aggregate basis, on a per-network basis, or on any granularity in-between.
+
+FIE-FE is independent of transport technology. At least one FIE-FE is required to reside within a single physical network. Assuming network edge nodes are the ASPs and AEPs for all flow aggregates, one possible implementation practice is to put an FIM-FE and FIE-FE pair into every edge node of a network. Another possibility is to put an FIM-FE into every edge node and a single FIE-FE in a network. Allowing multiple FIE-FEs in a network ensures scalability. Example use cases are described in Appendix V.
+
+#### **7.4.3 FA information gathering functional entity (FIG-FE)**
+
+FIG-FE is the final point of the information gathering and processing. FIG-FE is required to reside in a network in an end-to-end path. FIG-FE is responsible for handling requests from applications it is associated with. Requests from applications are generally related to the end-to-end QoS provisioning. In order to meet the request from applications, FIG-FE is required to be able to gather FA tables, process them, and generate the relevant information that can be used by the requesting
+
+application. Examples of how applications utilize information from FIG-FEs are described in Appendices II and III.
+
+## **7.5 Reference points**
+
+#### **7.5.1 Reference point Fa**
+
+The reference point Fa allows the FA information gathering functional entity (FIG-FE) to gather information from FA information exchange functional entities (FIE-FEs) from various networks, including the FIE-FEs of other domains. Fa also allows the requests from FIG-FE to be transferred to FIE-FE.
+
+#### **7.5.2 Reference point Fb**
+
+The reference point Fb allows the exchange of information among FIE-FEs in different domains. In Cascade mode, where FIG-FE is fully distributed, the information gathering from remote domains is done through the cooperation among FIE-FEs of multiple domains. In such a case, domain level multi-hop exchange is necessary. The Fb also allows the domain level multi-hop exchange.
+
+#### **7.5.3 Reference point Fc**
+
+The reference point Fc allows the exchange of information among FIE-FEs within a domain, in the case where there are multiple FIE-FEs in a single domain.
+
+#### **7.5.4 Reference point Fd**
+
+The reference point Fd allows the uploading of the managed information to FIE-FE from FIM-FE. Fd also allows the requests from FIE-FE to be transferred to FIM-FE.
+
+#### **7.5.5 Reference point Fu**
+
+The reference point Fu allows the information gathered and processed by FIG-FE to be transferred to applications. Fu also allows the requests from applications to be transferred to FIG-FE.
+
+# **8 Information to be exchanged**
+
+The following parameters are required to be gathered, stored, updated, and exchanged over the networks. A complete set of the listed parameters is a FA table entry. A possible allocation scheme of bits and values for the parameters is described in Appendix VI. Also, since the listed parameters' corresponding terminologies and concepts are different among networks, example mappings for the standard parameters and network-specific parameters are described in Appendix VII.
+
+## **8.1 Parameters not specific to a FA**
+
+#### **8.1.1 Mapping rule from flow ID to FA ID**
+
+This field specifies the transport technology of the network and more specifically the policy (or the rule) with which the network maps a flow to a proper flow aggregate.
+
+It is required that this field be exchanged per network and not be stored and exchanged per FA.
+
+Networks are to exchange information on whether their unique policy for mapping IP-level flows into a FA is static or dynamic. By informing such a rule, the informed network can infer to which FA the flow under estimation would belong. Sometimes, it is enough to notify the transport technology, but sometimes it is not. How to describe exactly the complex nature of the mapping policy is an open question.
+
+#### **8.1.2 Bandwidth allocation enforcement method or scheduling method**
+
+This field specifies the scheduling method employed by the network, with which the network can provision a certain amount of bandwidth resource to a flow aggregate.
+
+It is required that this field be exchanged per network and not be stored and exchanged per FA.
+
+It is clear that the scheduling policy determines the bandwidth allocated to a given FA, explicitly or implicitly. The schedulers can be categorized into the WFQ (weighted fair queuing)-type rate-guaranteeing schedulers (the explicit rate enforcers), the priority schedulers (the implicit ones), and others. The FIFO and strict priority schedulers can be seen as the special types of the priority schedulers. The schedulers can also be divided into FA-(or flow) based and class-(or service context) based. While the rate-guaranteeing schedulers usually are FA based, and the class-based one is the priority scheduler, the other combinations exist as well. The DiffServ-TE rate allocation methods (Russian Dolls Models [b-IETF RFC 4127], etc.) per class are the examples.
+
+## **8.2 FA parameters**
+
+#### **8.2.1 Representative (R)**
+
+This field, R field in short, has a value of either true or false. When true, it means that this set of FA parameters is the representative of an entire network domain, not just for a FA.
+
+A FA table entry is required to reside in every aggregation region for every FA. A FA table, a set of FA table entries, is managed by an FIM-FE. In DiffServ, this could mean that every node has a FA table for BAs (behaviour aggregates). In order to reduce such a complexity, a representative FA table can be maintained per network. Instead of maintaining and exchanging tables for the FAs, a network can optionally maintain a single representative FA table. For example, a DiffServ network can maintain a representative FA table, and send this information to every requesting network.
+
+### **8.2.2 FA identifier**
+
+This field specifies the identity of FA.
+
+This field is void if R field is true.
+
+The value of this field is specific to the transport technology. For example, in an MPLS network, it can be an LSP label.
+
+#### **8.2.3 Number of flows within the FA**
+
+This field specifies the current number of flows in a FA. If R field is true, then this field specifies the maximum number of flows in a FA among all the FAs in the network. Because the number of flows in a FA is different from FA to FA, it is required to describe a worst case as a representative of a whole network.
+
+#### **8.2.4 Maximum packet length divided by link capacity**
+
+This field specifies the maximum value of packet length, among packets that pass through a link, divided by the link capacity among all the links in the path of the FA in the network.
+
+If R field is true, then this field specifies the maximum value of packet length divided by link capacity across all the links in the network.
+
+It is likely that the capacities of links within an aggregation region vary. While it would be desirable if every capacity is known, it is hard to handle all the information. The minimum of link capacities gives the worst delay bound; therefore this field gives a conservative estimate of delay performance.
+
+#### **8.2.5 Number of hops within the aggregation region or the policy region**
+
+This field specifies the number of hops the FA traverses within the aggregation region.
+
+If R field is true, then this field specifies the maximum number of hops within the domain, over a path of any flow. The radius of an aggregation region is a critical parameter for estimating the delay performance of the packets inside a FA. Usually more hops in an aggregation region gives a better
+
+delay performance. In a pure DiffServ network, the value of this parameter is one, i.e., the flows within a class are de-aggregated at the very next node.
+
+#### **8.2.6 Maximum number of aggregation regions**
+
+If R field is true, then this field specifies the maximum number of aggregation regions a flow traverses in the network, among all the flows in the network. If R field is false, then this field is required to have the value of one.
+
+#### **8.2.7 Maximum sum of sustainable transfer rates (Rs) divided by link capacity**
+
+This field specifies the maximum value of the sum of sustainable transfer rates (Rs) of flows within the FA divided by link capacity, across all the links the FA traverses in the aggregation region.
+
+If R field is true, then this field specifies the maximum value of the sum of sustainable transfer rates of flows within a FA divided by link capacity, across all the FAs and all the links the FA traverses in the network. Some QoS architectures do not require the sustainable transfer rate to be specified by end users. In this case this value may be left unknown.
+
+#### **8.2.8 Maximum sum of sustainable burst sizes (Bs) divided by link capacity**
+
+This field specifies the maximum value of the sum of sustainable burst sizes (Bs) of flows within the FA divided by link capacity, across all the links the FA traverses in the aggregation region.
+
+If R field is true, then this field specifies the maximum value of sum of sustainable burst sizes of flows within a FA divided by link capacity, across all the FAs and all the links the FA traverses in the network. Some QoS architectures do not require the burst tolerance to be specified by end users. In this case this value may be left unknown.
+
+#### **8.2.9 Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority**
+
+The type of scheduler used in a network is specified by the field 'Bandwidth allocation enforcement method'. Based on the scheduler type, this field has a different meaning as follows.
+
+If the schedulers in the aggregation region are rate-guaranteeing ones, then this field specifies the minimum value of guaranteed service rate for the FA divided by the sum of Rs of flows within the FA, across all the links within the path the FA traverses.
+
+If the schedulers are priority-based ones, then this field specifies the priority level given to the FA.
+
+In this case, this field represents the relative priority assigned to the FA. How to exactly assign the eight bits into scheduling priorities is technology dependent.
+
+The decision process for the allocated rate, whether it is static or dynamic with measurement, is not covered in this Recommendation.
+
+#### **8.2.10 Packet discard priority**
+
+This field specifies the packet discard priority assigned to the FA.
+
+This field corresponds to the drop precedence field in DSCP. It effectively indicates the buffer space allocation priority among FAs.
+
+#### **8.2.11 Class (service context)**
+
+This field specifies the service class assigned to the FA.
+
+This field can be mapped to the service context in FSA networks. Each DSCP value for BA indication in DiffServ and each value for the service context indication (e.g., Decimal 10 for AF11 BA) should be used intact.
+
+## 8.3 Parameters exchanged at the reference points
+
+Table 2 specifies what information parameters are required to be exchanged by which reference points.
+
+**Table 2 – Parameters to be exchanged at reference points**
+
+| Taxonomy | Parameter | Fa | Fb | Fc | Fd |
+|---------------------------------|----------------------------------------------------------------------------------------------|-----------|-----------|-----------|-----------|
+| Parameters not specific to a FA | Mapping rule (policy) from Flow ID (IP 5-tuple) to FA ID. | ✓ | ✓ | | |
+| | Bandwidth allocation enforcement method or (scheduling method). | ✓ | ✓ | | |
+| FA parameters | Representative (R). | ✓ | ✓ | ✓ | ✓ |
+| | FA identifier. | ✓ | ✓ | ✓ | ✓ |
+| | Number of flows within the FA. | ✓ | ✓ | ✓ | ✓ |
+| | Maximum packet length divided by link capacity. | ✓ | ✓ | ✓ | ✓ |
+| | Number of hops within the aggregation region or the policy region. | ✓ | ✓ | ✓ | ✓ |
+| | Maximum number of aggregation regions. | ✓ | ✓ | ✓ | ✓ |
+| | Maximum sum of sustainable transfer rates (Rs) divided by link capacity. | ✓ | ✓ | ✓ | ✓ |
+| | Maximum sum of sustainable burst sizes (Bs) divided by link capacity. | ✓ | ✓ | ✓ | ✓ |
+| | Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority. | ✓ | ✓ | ✓ | ✓ |
+| | Packet discard priority. | ✓ | ✓ | ✓ | ✓ |
+| | Class (service context). | ✓ | ✓ | ✓ | ✓ |
+
+# 9 Security considerations
+
+This clause describes security threats and potential attacks and defines security requirements for performing information exchange. The security requirements are based on [ITU-T Y.2701].
+
+Although information exchange among network domains is not expected to add specific security extensions, greater considerations are required in terms of how to establish a trusted model across network domain boundaries. Networks are required to have a means to authenticate, allow, and possibly deny inter-network requests. Also, networks are required to be protected from DoS attacks.
+
+Since the information exchange functions and the use of such information completely rely on other networks' cooperation, if the information from other networks is not trustworthy, then the whole operation would be meaningless. Furthermore, the network's operating status would be revealed if confidentiality is not guaranteed. [ITU-T Y.2701] defines the network elements of the "untrusted zone" and possible threats in the peering network trust model. The following are the threats that may occur in the information exchange procedure.
+
+- alteration of information: This threat includes the destruction, corruption, modification, removal, or loss of information. Possible consequences are false information regarding resource allocation in other networks, inefficient allocation of resources, and misjudgement on admission decisions;
+- theft or disclosure of information: This can take place because of the interception of the FA tables or because of granting access to an illegitimate application. This threat may result in various privacy violations;
+
+- interruption of exchange services: This threat is typically realized through a denial of service (DoS) attack. Specifically, the resources (including the computing resources) can be exhausted by forcing them to process too many requests, or by authorization of illegitimate requests. A few known DoS attacks involve: 1) replaying the information exchange request (or response) messages; 2) injection or modification of the request (or response) messages; and 3) flooding, where an adversary sends a large number of requests. The processing of such requests may exhaust the resources, rendering them unavailable for requests from the legitimate operators.
+
+A number of well-known security mechanisms have been either proven or deemed appropriate for mutual authentication and provision of integrity and confidentiality. Transport layer security (TLS) [b-IETF RFC 2246] and IPsec [b-IETF RFC 4301] protocols already employ such mechanisms to provision the transport and network layer security, respectively.
+
+The major security requirements for networks adopting FA information exchange functions are:
+
+- protection of the signalling request/response exchange in support of information exchange;
+- protection of the information contained in all functional entities involved in this exchange;
+- ensuring the availability and overall expected performance of the information exchange;
+- preventing illegitimate access to functional entities from any untrusted network element.
+
+The ways of preventing illegitimate access may include authentication between functional entities from different trust domains, non-repudiation support, firewall, and secure channel mechanisms such as TLS and IPsec.
+
+# Appendix I
+
+## Typical network topology for FA parameter exchange
+
+(This appendix does not form an integral part of this Recommendation)
+
+The FA parameter exchange procedure is not specific to the network topology. It is required that the control procedure be applicable to any type of network topology. In this appendix, we will use an example of the generic network topology to describe the FA parameter exchange operation.
+
+Figure I.1 describes the generic network topology. The network topology assumes several network domains where each domain of the network makes use of a specific FA technology (e.g., MPLS). For collecting the FA information, the three FEs (e.g., FIM-FE, FIE-FE, and FIG-FE) are implemented in the network. As indicated in Figure I.1, the FIM-FE, FIE-FE, and FIG-FE are structured in a hierarchical manner. The three FEs are implemented in the switch or in the stand-alone server. The detailed description is as follows.
+
+- FIM-FE: The FIM-FE is usually co-located in the edge switches and maintains the information of the local FAs which are aggregated in the switch. Multiple FIM-FEs exist in each aggregate domain.
+- FIE-FE: The FIE-FE is responsible for collecting the FA information from multiple FIM-FEs. At least one FIE-FE exists in each aggregate domain. If the network size is big, it is recommended that multiple FIE-FEs exist in the network domain. In Figure I.1, domain C has two FIE-FEs. The multiple FIE-FEs in the same network domains are connected with Fc. It is recommended that only one of the FIE-FE in a domain be connected to the FIG-FE by Fa and to the FIE-FE of other domains by Fb. The FIE-FE is implemented in a separate server or co-located in an edge switch.
+- FIG-FE: The FIG-FE is responsible for collecting the FA information from multiple FIE-FEs. There is one FIG-FE in the network. Typically, the FIG-FE is implemented in a separate server.
+
+
+
+Y.2122(09)\_F1.1
+
+Figure I.1: Example of implementation topology for FA information exchange. The diagram shows a hierarchical network topology. At the top, a FIG-FE (standalone server) connects to an Application via link Fu. Below, three domains (A, B, C) are shown. Domain A and B are orange clouds, while Domain C is a blue cloud containing two aggregation regions (region 1 and region 2). FIE-FEs (blue circles) are located in each domain. FIM-FEs (blue switch icons) are located within the aggregation regions. Connections include Fa (FIG-FE to FIE-FE), Fb (FIE-FE to FIE-FE), Fc (FIE-FE to aggregation regions), and Fd (FIE-FE to aggregation regions). A red dashed line labeled 'E2E flow' passes through the domains. A yellow cylinder labeled 'Flow aggregate' is shown in Domain B. A legend at the bottom identifies the symbols: Aggregation region (blue outline), Domain (orange cloud), FIE-FE (blue circle), FIM-FE (blue switch icon), and Flow aggregate (yellow cylinder).
+
+Figure I.1 – Example of implementation topology for FA information exchange
+
+# Appendix II
+
+## A usage example – Admission decision process
+
+(This appendix does not form an integral part of this Recommendation)
+
+The network parameter exchange can be used in the admission decision process: Should a newly requested flow be accepted? Given the end-to-end performance budget, such as the IPTD value for Class 0 traffic: 100 ms, one can decide to accept the flow if the networks $N_1, N_2, \dots, N_n$ in the paths can guarantee $d_1$ ms, $d_2$ ms, $\dots$ , $d_n$ ms mean delays, and these sum up into a value less than 100 ms. As it has been pointed out in the Introduction, actual mean delay for this flow at each network cannot be measured prior to acceptance. The estimation or the prediction procedure should be conducted. Either of the two methods can be used for this purpose:
+
+- Collaborative estimation method:
+ - 1) Network parameters for flow aggregates are exchanged between neighbouring networks.
+ - 2) A flow ( $f$ ) requests admission, and during the call set-up it is determined to which flow aggregates ( $F_1, F_2, \dots, F_n$ ) the flow will belong in the networks in the path.
+ - 3) Based on the exchanged information on $F_1, F_2, \dots, F_n$ , the delays $d_1, d_2, \dots, d_n$ of $F_1, F_2, \dots, F_n$ are estimated at the networks $N_1, N_2, \dots, N_n$ , respectively. The estimation can be divided into two processes: the calculation based on the parameter values, and the adjustment based on the past monitoring.
+ - 4) $N_i$ gathers information of $d_1, d_2, \dots, d_n$ . So does any other network in the path.
+ - 5) $N_i$ can decide whether the flow can meet the requirements. So can any other network in the path.
+- Individual estimation method:
+ - 1) Network parameters for flow aggregates are exchanged between neighbouring networks.
+ - 2) A flow ( $f$ ) requests admission, and during the call set-up it is determined to which flow aggregates ( $F_1, F_2, \dots, F_n$ ) the flow will belong in the networks in the path.
+ - 3) Based on the exchanged information on $F_1, F_2, \dots, F_n$ , the delays $d_1, d_2, \dots, d_n$ of $F_1, F_2, \dots, F_n$ are estimated at network $N_i$ , and also at $N_{i+1}$ independently of $N_i$ , and so on. The estimation can be divided into two processes: the calculation based on the parameter values, and the adjustment based on the past monitoring.
+ - 4) $N_i$ can decide whether the flow can meet the requirements. So can any other network in the path.
+
+Note that the collaborative method requires a uniform framework for estimating the mean delay for every network in the path. Otherwise, even in exactly the same situation, different networks may generate a different estimated delay. Generally, it is assumed that the estimation processes are different from network to network, therefore the individual estimation method is preferred.
+
+The following is the estimation example for $d_i$ , for different types of networks, using the individual estimation method. Throughout this appendix the deterministic delay bound analysis technique has been adopted. Other analysis methods such as statistical delay analysis can also be used.
+
+Note that the administrators can adjust later the worst case delay bound into a more realistic one, for example, by observing the real delay distribution after the call has been accepted. By doing so, a mapping rule from the D to the mean delay can be established over time.
+
+### II.1 DiffServ expedited forwarding
+
+The delay bounds in a general topology network with the expedited forwarding PHB of the DiffServ architecture can be found in the bibliography. Let us denote $\rho_i$ and $\sigma_i$ as the leaky bucket parameters: the mean data rate and the maximum burst size of flow $i$ , respectively. Assume that all the flows with premium service are constrained with leaky bucket, and also assume that the premium service traffic receives strict scheduling priority over other traffic. An exemplary delay ( $D$ ) bound obtained in [b-Charny 00], [b-Wang 04], under the condition that $\alpha < 1/(H - 1)$ , and under assumption that the incoming links' capacity is infinite, and given as:
+
+$$D \leq \frac{H}{1 - (H - 1)\alpha} (\Delta + \tau) \quad (\text{II-1})$$
+
+where $H$ is the maximum hop count in the network, $\Delta = \max_S (L/r^S)$ , $r^S$ is the capacity of server $S$ , and $L$ is the maximum packet size. $\tau$ and $\alpha$ are defined by the inequalities $\sum_{j \in F_S} \sigma_j \leq \tau r^S$ , and $\sum_{j \in F_S} \rho_j \leq \alpha r^S$ , for any server $S$ in the network with capacity $r^S$ , in which there is a set of flows, $F_S$ . One may call $\tau$ the burst allowance level measured in time for their transmission, and $\alpha$ the network utilization.
+
+For a DiffServ network, the above equation for the delay bound of packets within the highest priority traffic can be used for inferring the IPTD. For example, given the hop count of a flow within a network ( $H$ ), the network utilization ( $\alpha$ ), and the burst allowance level ( $\tau$ ), the delay characteristics can be inferred.
+
+The key difficulty lies in calculating $\tau$ . In order to obtain this value, one has to know the maximum burst size ( $\sigma_i$ ) at the entrance of the network of every flow sharing the output queue, or the server, in a network. Other parameters such as $\alpha$ , $\Delta$ , and $H$ can be obtained from the traffic descriptor [b-ITU-T Y.1221] or from the inherited network characteristics. The $\sigma_i$ at the entrance of the network (burst-in) should therefore be provided from the neighbouring networks.
+
+### II.2 IntServ guaranteed rate service
+
+IntServ is now an obsolete QoS architecture which is not used in practice, except for its signalling protocol, RSVP. The myriad performance analyses on the end-to-end QoS are based mostly on IntServ, particularly on guaranteed service. The ideas from IntServ, such as resource reservation, flow protection, ingress regulation, etc. have been the key components of the numerous basic QoS provisioning architectures. It is, therefore, worth looking into the performance of IntServ networks, especially the delay bound.
+
+The rate-guaranteeing schedulers (or servers), formerly called guaranteed-rate (GR) servers [b-LeBoudec 01] or latency-rate (LR) servers [b-Stiliadis 98] play the key role in bounding the end-to-end delay. The end-to-end delay of a flow $i$ in a network with LR servers can be obtained by the following inequality from [b-Stiliadis 98]:
+
+$$D_i \leq \frac{\sigma_i - L_i}{\rho_i} + \sum_{j=1}^H \Theta_i^{S_j} \quad (\text{II-2})$$
+
+where $\Theta_i^{S_j}$ is the latency of the $j$ th server ( $S_j$ ) for the flow $i$ along the path of $i$ in the network. The latency is the parameter of an LR server that is uniquely given. For example, the well-known packetized generalized processor sharing (PGPS) server or its implementation equivalent weighted fair queuing (WFQ) server has the latency:
+
+$$\Theta_i^{PGPS} = \frac{L_i}{\rho_i} + \frac{L_{\max}}{r} \quad (\text{II-3})$$
+
+where $L_i$ is the maximum packet length of flow $i$ , and $L_{max}$ is the maximum packet length of all the flows in the server. Another popular scheduler of LR server class is the Deficit Round Robin (DRR). Its latency is given as follows.
+
+$$\Theta_i^{DRR} = \frac{3F - 2\phi_i}{r} \quad (II-4)$$
+
+where $\phi_i$ is the quantum value, or the relative portion of the server capacity given to flow $i$ , and $F$ is the sum of the $\phi_j$ for all the flows within the server.
+
+As can be seen from equations II-2, II-3, and II-4, the end-to-end delay bound of an IntServ network can be calculated only from the parameters in the traffic descriptor, except $\sigma_i$ , the maximum burst size of flow $i$ at the entrance of the network, or the burst-in, which is different from what the flow has described at the UNI.
+
+The "Pay burst only once" principle, however, comes in here. If two or more contiguous networks implement the IntServ-type rate-guaranteeing schedulers for a flow, the flow is protected throughout the networks, and these networks can be thought of as a single network and the delay component due to $\sigma_i$ in equation II-2 is applied only once to the delay bound calculation. This principle is called "Pay burst only once".
+
+### II.3 Networks with various granularity flow aggregation (MPLS, FSA in [b-ITU-T Y.2121], etc.)
+
+Theoretically, the rate-guaranteeing servers in the IntServ architecture will give exactly the same amount of service to a flow aggregate and to a micro-flow, given that the allocated rates are the same. Therefore, within a single aggregation region, the delay bound of a flow aggregate $i$ can be calculated from equation II-2 as well. In this case, the maximum burst size $\sigma_i$ is the sum of all the maximum burst sizes of the flows within the aggregate, and the mean data rate $\rho_i$ is, again, the sum of all the mean data rates of the flows within the aggregate.
+
+It is noteworthy that for a flow aggregate, when compared to a flow within the end-to-end delay bound can be reduced.
+
+### II.4 Calculation of the burst-in or equivalently the burst-out
+
+As it has been observed, one of the most important parameters that has to be exchanged to calculate the delay bound of a network is the burst-in value of flows.
+
+Therefore, a network has to be able to provide the burst-out value of a flow to the neighbouring networks. It has been suggested [b-Stiliadis 98] that the burst-out of a network can be calculated by:
+
+$$\sigma_i^{out} = \sigma_i^{in} + \rho_i \sum_{k=1}^H \Theta_i^{S_k} \quad (II-5)$$
+
+where $\sigma_i^{in}$ and $\sigma_i^{out}$ are the burst-in and burst-out of the flow $i$ , respectively, and $\Theta_i^{S_k}$ is the latency of the $k$ th server ( $S_k$ ) for the flow $i$ along the path of $i$ in the network. The latencies of servers in different QoS architectures are given as follows.
+
+For a DiffServ network, the latency for a flow $i$ in a strict priority queuing server $S$ is given as:
+
+$$\Theta_i^S = \frac{\sigma^S - \sigma_i^S + 2L}{r^S} \quad (II-6)$$
+
+where $\sigma^S$ is the sum of all the maximum burst sizes of the flows that share the server with $i$ . It is now clear that the burst-out of a flow is a function of the burst-ins of the flows that the flow under observation ( $i$ ) has met in the path in a network.
+
+For a DiffServ network, therefore, it is required information from neighbouring networks such as the burst-in of the incoming flows, other than parameters specified in the traffic descriptor. The burst-ins of flows, or similarly the burst-outs of flows into another network, however, can be burdensome to calculate for a core network. There can be an approximation approach for calculating burst-ins from other networks.
+
+For an IntServ network, the latencies of various servers are given, and two of them are listed in equations II-3 and II-4.
+
+For networks with flow aggregation, under conditions that all the flows in a flow aggregate are leaky bucket constrained in front of an LR server $S$ , and the aggregated data rate is less than the link capacity, the LR server for the flow aggregate is still an LR server for individual flows, with latency given as follows:
+
+$$\Theta_i^S = \frac{\sigma_I^S - \sigma_i^S}{\rho_I} + \Theta_I^S \quad (\text{II-7})$$
+
+where $I$ is the flow aggregate, to which $i$ belongs in the server.
+
+# Appendix III
+
+## A usage example – Flow granularity and continuity decision process
+
+(This appendix does not form an integral part of this Recommendation)
+
+For networks having flow aggregation capability with variable granularity and continuity, QoS consideration should be an issue when it comes to the decision on the granularity and continuity of a flow aggregate. The reason for this is that QoS performance depends heavily upon these characteristics of a flow aggregate. It is generally well understood that the FA with large granularity lacks protection to an individual flow from other bursty traffic. Smaller scale FA is therefore preferable, yet it has to overcome the scalability problem. It is again generally understood that the FA with longer continuity gives a better delay performance, yet with less scalability. The network operator has to decide about the ubiquitous performance-scalability compromise. How many IP flows should be in an LSP? How long is the path of an LSP? One can simply put all the IP flows with the same source-destination pair into a single LSP. One can go further to put traffic type into consideration, therefore IP flows with the same source-destination pair and the same application may only be in a same FA. On the other hand, when the network is large, one can avoid having too many FAs to handle by dividing a network into several subnetworks, therefore reducing continuity and increasing granularity.
+
+In terms of QoS performance, it is sometimes enough for a network not to violate an allocated performance margin for a flow. In other words, if a network knows that the sum of impairments incurred by the other networks in the path is safely lower than what is requested, the network may shorten the continuity of the FA, given that all the flows' requests are sufficiently met. The following FA granularity and continuity decision process may be adopted for efficient complexity management for a network.
+
+## III.1 FA granularity and continuity decision process
+
+- Network parameters for flow aggregates are exchanged between neighbouring networks.
+- Based on the exchanged information, for a flow in FA ( $F_i$ ), the performance measures (e.g., delay) in the path ( $p_1^i, p_2^i, \dots, p_n^i$ ) are estimated. The estimation can be divided into two processes: the calculation based on the parameter values, and the adjustment based on the past monitoring. Similarly, for all $i$ in the FA, the performance measures are estimated.
+- For the FA ( $F$ ), it has been discovered that all the flows inside $F$ enjoy sufficient margins in performance requirements, throughout the paths; or for the FA ( $F$ ), if its performance per hop in the current network is sufficiently different from those of the neighbouring networks, the network can decide whether the FA can alter its granularity and continuity.
+
+# Appendix IV
+
+## FIM-FE usage scenarios
+
+(This appendix does not form an integral part of this Recommendation)
+
+In this appendix, some of the scenarios regarding FIM-FE usage are considered.
+
+### IV.1 FA table entry writing
+
+The proper parameters for a given FA can be obtained by either a signalling or a management procedure. For example, if FIM-FE is at the ASP, then ASP can send a request message to the downstream nodes in the AR. The nodes within the AR in response fill the tables. The AEP can return a reply message back to the ASP.
+
+On the contrary, FA parameters may not be obtained from individual nodes. Rather, it can be induced from the network's flow aggregation policy. For example, if a network aggregates incoming flows using a strict rule, such that the sum of sustainable rates does not exceed a pre-defined ratio of the total capacity, this rule itself can be written in the corresponding field in the FA table as a maximum value. With such an induction, the accuracy of the information written in a FA table will be somewhat downgraded. The obvious gain from the loss of accuracy is more scalability.
+
+### IV.2 Information management mechanism for multiple ARs in a single network
+
+In case where there are multiple ARs for a flow in a network, the FIM-FEs are required to reside per AR, as in Figure IV.1.
+
+
+
+Y2122(09)\_FIV-1
+
+Diagram illustrating FIM-FEs for multiple ARs in a single network. A large rectangle labeled 'Network' contains three overlapping ovals labeled 'AR'. Each 'AR' oval contains a smaller oval labeled 'FIM-FE'.
+
+Figure IV.1 – FIM-FEs for multiple ARs in a network
+
+### IV.3 Information management mechanism for a single AR over multiple networks
+
+Similarly, there can be cases where a single AR covers multiple network domains, for example with inter-domain MPLS LSPs [b-IETF RFC 4216]. In such a case an FIM-FE is required to reside only for an AR, not for a network, as depicted in Figure IV.2.
+
+
+
+Y2122(09)\_FIV-2
+
+Diagram illustrating FIM-FEs for a single AR in multiple networks. Two rectangles labeled 'Network' are shown side-by-side. A large oval labeled 'AR' spans across both 'Network' rectangles. Inside the 'AR' oval is a smaller oval labeled 'FIM-FE'.
+
+Figure IV.2 – FIM-FEs for single AR in multiple networks
+
+# Appendix V
+
+## FIE-FE usage scenarios
+
+(This appendix does not form an integral part of this Recommendation)
+
+In this appendix, some of the scenarios regarding FIE-FE usage are considered.
+
+### V.1 Cases of information exchange for multiple-ARs in a network
+
+Since a requesting entity does not have information on the identity of a FA on a requested network, the request query is likely to be based on flow identity. The requested network is required to respond with the corresponding FA table(s).
+
+If there are multiple ARs in a network for a flow (a good example of such multiple ARs in a network would be one with MPLS LSP aggregation [b-IETF RFC 4206] capability), the corresponding FA tables for a specific flow are recommended to be handled by a single FIE-FE per network. The FIE-FE responsible for a specific FA can be either within an aggregation region (AR) or in a central management entity in the network. If the FIE-FE is within an AR, it can be either at the aggregation start point (ASP) or at the aggregation end point (AEP).
+
+### V.2 Cases of information exchange for a single AR in multiple networks
+
+If the requested entity does not have an FIM-FE within the network, because the FA's AR covers multiple networks and the corresponding FIM-FE is on another network, then the requested network is required to be able to get the FA information from the FIM-FE on another network. Therefore the Fd interface can be formed over network boundaries, as depicted in Figure V.1.
+
+
+
+The diagram shows two rounded rectangular boxes representing 'Network' entities. The left network contains an oval labeled 'FIE-FE' and a larger oval labeled 'FIM-FE'. The right network contains an oval labeled 'FIE-FE'. A large, wide oval labeled 'AR' spans across both networks, containing the 'FIM-FE' in the left network. A line labeled 'Fd' originates from the 'FIE-FE' in the right network, passes through the 'AR' oval, and terminates at the 'FIM-FE' in the left network. The text 'Y2122(09)\_FV-1' is located at the bottom right of the diagram.
+
+Diagram illustrating the Fd interface over network boundary. Two networks are shown, each containing a FIE-FE entity. A central AR entity spans both networks. A FIM-FE entity is located within the AR in the left network. A line labeled 'Fd' connects the FIE-FE in the right network to the FIM-FE in the left network, passing through the AR. The label 'Y2122(09)\_FV-1' is at the bottom right.
+
+Figure V.1 – Fd interface over network boundary
+
+# Appendix VI
+
+## Example allocation of FA parameter values
+
+(This appendix does not form an integral part of this Recommendation)
+
+In this appendix, an example strategy for allocating FA parameter bits and values is recommended.
+
+### VI.1 Mapping rule from flow ID to FA ID
+
+This field is recommended to have 8 bits. The following table shows the assigned binary code with the MSB four bits to the transport technology of the network and the mapping policy.
+
+**Table VI.1 – Recommended bits assignment for mapping rule**
+
+| | MSB (Bit 7) | Bit 6 | Bit 5 | Bit 4 |
+|-------------------------|--------------------|--------------|--------------|--------------|
+| Best-effort | 0 | 0 | 0 | 0 |
+| DiffServ | 0 | 1 | 0 | X |
+| DiffServ with TE | 0 | 1 | 1 | X |
+| MPLS and its variations | 1 | 0 | X | X |
+| FSA | 1 | 1 | X | X |
+| Reserved | 0 | 0 | 1 | X |
+
+The LSB four bits will indicate technology-specific mapping rule. The detailed assignment is for further study.
+
+### VI.2 Bandwidth allocation enforcement method or scheduling method
+
+This field is recommended to have 8 bits.
+
+**Table VI.2 – Recommended bits assignment for scheduling method**
+
+| | MSB (Bit 7) | Bit 6 | Bit 5 |
+|----------------------------------------------------------------------|--------------------|--------------|--------------|
+| Rate-guaranteeing schedulers | 0 | X | X |
+| Priority schedulers | 1 | 0 | 0 |
+| Class based bandwidth sharing schedulers (DiffServ-TE variations) | 1 | 0 | 1 |
+| Reserved (including non work-conserving schedulers) | 1 | 1 | X |
+
+The schedulers will be further specified by the remaining five bits. This further categorization is for future work.
+
+### VI.3 Representative (R)
+
+This field is recommended to be 1 bit.
+
+### VI.4 FA identifier
+
+This field is recommended to have 31 bits.
+
+### **VI.5 Number of flows within the FA**
+
+This field is recommended to have 8 bits. This field is recommended to strictly follow the normalized exponential notation. The most significant four bits represent the coefficient, in decimal, and the least significant four bits represent the exponent, also in decimal. Therefore, for example, if there are 2340 flows within a FA, then this field is recommended to be "0010\_0011" which represents $2 \times 10^3$ . Similarly, "1111\_0100" represents $1.5 \times 10^8$ flows within a FA.
+
+Note that the most significant four bits "1011" represent the coefficient 1.1, not 11. If the actual coefficient is more than or equal to 1.6 and less than 2.0, then the most significant four bits are suggested to be 0010, i.e., 2 in decimal. The range of this field can be from 0 to $9 \times 10^{15}$ in decimal.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### **VI.6 Maximum packet length divided by link capacity**
+
+This field is recommended to have 8 bits. The unit of this field is "seconds". This field is recommended to follow the normalized exponential notation. The most significant four bits represent the coefficient, in decimal, and the least significant four bits represent the exponent, also in decimal. The exponent is assumed to be a negative number without any extra bit to mark. Therefore, for example, $1.2 \times 10^{-5}$ can be written as "1100\_0101".
+
+The range of this field can be from $1 \times 10^{-15}$ to 9 in decimal.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### **VI.7 Number of hops within the aggregation region or the policy region**
+
+This field is recommended to have 8 bits. The range of this field can be from 0 to 255.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### **VI.8 Maximum number of aggregation regions**
+
+This field is recommended to have 8 bits. The range of this field can be from 0 to 255. The value "0000\_0000" means that the real value of this field is unknown.
+
+### **VI.9 Maximum sum of sustainable transfer rates (Rs) divided by link capacity**
+
+This field is recommended to have 8 bits. This field specifies the ratio of the link capacity to the nominal sustainable rate of the FA. It is unlikely for the value of this field to exceed one. This field is recommended to follow the normalized exponential notation. The most significant four bits represent the coefficient in decimal and the least significant four bits represent the exponent also in decimal. The exponent is assumed to be a negative number without any extra bit to mark. Therefore, for example, $1.2 \times 10^{-5}$ can be written as "1100\_0101".
+
+The range of this field can be from $1 \times 10^{-15}$ to 9 in decimal.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### **VI.10 Maximum sum of sustainable burst sizes (Bs) divided by link capacity**
+
+This field is recommended to have 8 bits. This field specifies the ratio of the link capacity to the nominal sustainable burst size of the FA. This field is recommended to follow the normalized exponential notation with sign. The most significant four bits represent the coefficient, in decimal, the least significant bit represents the sign of the exponent, and the remaining three bits represent the exponent, also in decimal. Therefore, for example, $1.2 \times 10^{-5}$ can be written as "1100\_101\_1". The least significant bit 1 represents a minus sign.
+
+The range of this field can be from $1 \times 10^{-7}$ to $9 \times 10^7$ in decimal.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### VI.11 Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority
+
+This field is recommended to follow the normalized exponential notation. The most significant four bits represent the coefficient and the least significant four bits represent the exponent of the minimum guaranteed service rate divided by the sum of Rs. The exponent is assumed to be always negative or zero. Therefore, for example, $1.2 \times 10^{-5}$ can be written as "1100\_0101".
+
+The range of this field can be from 9 to $1 \times 10^{-15}$ in decimal.
+
+The value "0000\_0000" means that the real value of this field is unknown.
+
+### VI.12 Packet discard priority
+
+This field is recommended to have 4 bits. The range of this value is 0 to 255.
+
+### VI.13 Class (service context)
+
+This field is recommended to have 8 bits. The range of this value is 0 to 255.
+
+### VI.14 Summary
+
+Table VI.3 summarizes the example parameter bits allocated in this appendix.
+
+**Table VI.3 – Recommended bit assignment for parameters**
+
+| Taxonomy | Field | Number of bits | Range |
+|---------------------------------|---------------------------------------------------------------------------------------------|----------------|---------------------------------------|
+| Parameters not specific to a FA | Mapping rule (policy) from Flow ID (IP 5-tuple) to FA ID | 8 | |
+| | Bandwidth allocation enforcement method or (scheduling method) | 8 | |
+| FA parameters | Representative (R) | 1 | 0 to 1 |
+| | FA Identifier | 31 | 0 to $2^{31}-1$ |
+| | Number of flows within the FA | 8 | 0 to $9 \times 10^{15}$ |
+| | Maximum packet length divided by link capacity | 8 | $1 \times 10^{-15}$ to 9 |
+| | Number of hops within the aggregation region or the policy region | 8 | 0 to 255 |
+| | Maximum number of aggregation regions | 8 | 0 to 255 |
+| | Maximum sum of sustainable transfer rates (Rs) divided by link capacity | 8 | $1 \times 10^{-15}$ to 9 |
+| | Maximum sum of sustainable burst sizes (Bs) divided by link capacity | 8 | $1 \times 10^{-7}$ to $9 \times 10^7$ |
+| | Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority | 8 | 9 to $1 \times 10^{-15}$ |
+| | Packet discard priority | 8 | 0 to 255 |
+| | Class (service context) | 8 | 0 to 255 |
+
+## **Appendix VII**
+
+## **Network specific parameter values**
+
+(This appendix does not form an integral part of this Recommendation)
+
+The purpose of this appendix is to recommend how the values of parameters are determined for each transport technology. The parameters defined in clause 8 can be interpreted differently depending on the network. How these fields can be interpreted in different networks will be elaborated in separate subclauses.
+
+The examples of the DiffServ, DS-MPLS [b-IETF RFC 3270] networks, FSA networks are considered. It is also considered how the FA parameters are assigned with the inherent network parameters within such networks.
+
+### **VII.1 DiffServ network specific parameters**
+
+#### **VII.1.1 Representative (R)**
+
+In DiffServ networks, an AR contains usually only a single node. As a consequence, the management of the FA table can be cumbersome, although the number of FAs in a node is far smaller compared to other types of networks. It is expected that a DiffServ network may easily set this field to true.
+
+#### **VII.1.2 FA identifier**
+
+If the R field is false, this field in a DiffServ network is recommended to indicate 6-bit DiffServ code point (DSCP) [b-IETF RFC 2474]. The matching FA identifier will be the six bits from bit 7 to bit 2. Optionally, the two explicit congestion notification (ECN) bits may be copied to bit 1 and bit 0 of this field.
+
+#### **VII.1.3 Number of flows within the FA**
+
+If the R field is false, this field in a DiffServ network is recommended to indicate the number of flows within the behaviour aggregate with the same DSCP.
+
+#### **VII.1.4 Packet discard priority**
+
+This field corresponds to the drop precedence field in DSCP. It effectively indicates the buffer space allocation priority among FAs. Since the DSCP is carried in the FA identifier field, this field may be set to zero, i.e., "0000\_0000".
+
+#### **VII.1.5 Class (service context)**
+
+Since the DSCP is carried in the FA identifier field, this field may be set to zero, i.e., "0000\_0000".
+
+#### **VII.1.6 Other fields**
+
+If the R field is false, the other fields are recommended to represent corresponding information, considering the BA as the FA.
+
+### **VII.2 DiffServ with traffic engineering (TE) network specific parameters**
+
+#### **VII.2.1 FA identifier**
+
+The FA identifier in a DiffServ-TE network is recommended to represent, among the 32-bit top level (if hierarchical header is being used) label stack; a 20-bit label value, a 3-bit field for QoS (quality of service) priority (experimental), and a 1-bit bottom of stack flag. The matching FA identifier is suggested to be from bit 23 to bit 0.
+
+#### **VII.2.2 Minimum guaranteed service rate divided by sum of Rs (if rate-based) or scheduling priority**
+
+The right value of this field for DiffServ-TE networks is intuitively unclear, due to the sharing nature of the scheduling policies adopted in these networks. Current dominant practices of bandwidth sharing methods include the Russian Dolls model (RDM) [b-IETF RFC 4127] and the maximum allocation model (MAM) [b-IETF RFC 4125]. Other mechanisms are being proposed as well (e.g., maximum allocation with reservation (MAR) [b-IETF RFC 4126]).
+
+This field in DiffServ-TE networks is recommended to indicate "the average minimum guaranteed bandwidth given to the LSP (or FA)" by the following calculation.
+
+For both RDM and MAM, this field is recommended to indicate the 'Reserved(CTi )' value divided by the number of LSPs from CTi , where CTi is the Class Type to which the current LSP (or FA) belongs. The eight bits will indicate this value with normalized exponential notation. 'Reserved(CTi )' is defined as the total amount of the bandwidth reserved by all the established LSPs which belong to CTi .
+
+In RDM, for the Class Type *i* (CTi ), with *i* from 0 to 7, the total amount of bandwidth reserved from CT7 to CTi (Reserved (CT7 ) + ... + Reserved (CTi )) must be less than BCi . BC0 is then defined as the maximum reservable bandwidth. Therefore, all LSPs from CT7 use no more than BC7 ; all LSPs from CT6 and CT7 use no more than BC6 ; all LSPs from CT5 , CT6 and CT7 use no more than BC5 ; etc. In MAM, the sharing mechanism is a bit simpler such that the all LSPs from CTi use no more than BCi . The key sharing idea here is that the sum of Reserved(CTi ) over all *i* must be less than or equal to the maximum reservable bandwidth. For a network management entity, specifying a real value of the assigned bandwidth for a single LSP is hard, if not impossible, because it dynamically changes over time. Therefore, in both practices (RDM and MAM), specifying a worst case is the best alternative, even if it may be far from the bandwidth actually assigned to a single LSP.
+
+#### **VII.2.3 Class (service context)**
+
+The Class Type of the LSP (or FA) is recommended to be specified in this field. Each DSCP value for BA indication in DiffServ (e.g., Decimal 10 for AF11 BA) should be used intact. The matching bits to DSCP are recommended to be the six bits from bit 7 to bit 2. Optionally, the two explicit congestion notification (ECN) bits may be copied to bit 1 and bit 0 of this field.
+
+#### **VII.2.4 Other fields**
+
+If the R field is false, the other fields are recommended to represent corresponding information, considering the LSP (E-LSP or L-LSP) as the FA.
+
+### **VII.3 Flow state aware (FSA) network specific parameters**
+
+#### **VII.3.1 FA identifier**
+
+In FSA networks, ingress edge nodes may support the option to aggregate selected flows into a flow aggregate, based on some criteria such as the service context, the preference indicator value, and the path in the network. The identifier for the flow aggregate, however, is not specified in FSA networks. Instead it is recommended to use an MPLS label for the identifier. In such a case, the FA identifier for FSA networks is suggested to be the MPLS label as well.
+
+The FA identifier in FSA networks is recommended to represent, among the 32-bit top level (if hierarchical header is being used) label stack; a 20-bit label value, a 3-bit field for QoS (quality of service) priority (experimental), and a 1-bit bottom of stack flag. The matching FA identifier is recommended to be from bit 23 to bit 0.
+
+#### **VII.3.2 Packet discard priority**
+
+This field is recommended to represent the packet discard priority (with the same name in this Recommendation) field defined in FSA networks. Since the exact usage of header fields for FSA networks must be specified, it is to be decided how this field will be specified as well.
+
+#### **VII.3.3 Class (service context)**
+
+This field is recommended to represent the service context (with the same name in this Recommendation) field defined in FSA networks. Since the exact usage of header fields for FSA networks must be specified, it is to be decided how this field will be specified as well.
+
+#### **VII.3.4 Other fields**
+
+If the R field is false, the other fields are recommended to represent corresponding information.
+
+# Bibliography
+
+- [b-ITU-T Y.1221] Recommendation ITU-T Y.1221 (2002), *Traffic control and congestion control in IP-based networks*.
+- [b-ITU-T Y.2121] Recommendation ITU-T Y.2121 (2008), *Requirements for the support of flow-state-aware transport technology in NGN*.
+- [b-ITU-T Y.2173] Recommendation ITU-T Y.2173 (2008), *Management of performance measurement for NGN*.
+- [b-IETF RFC 2246] IETF RFC 2246 (1999), *The TLS Protocol Version 1.0*.
+- [b-IETF RFC 2474] IETF RFC 2474 (1998), *Definition of the Differentiated Services Field (DS Field) in the IPv4 and IPv6 Headers*.
+- [b-IETF RFC 2475] IETF RFC 2475 (1998), *An architecture for Differentiated Services*.
+- [b-IETF RFC 3270] IETF RFC 3270 (2002), *Multi-Protocol Label Switching (MPLS) Support of Differentiated Services*.
+- [b-IETF RFC 4125] IETF RFC 4125 (2005), *Maximum Allocation Bandwidth Constraints Model for Diffserv-aware MPLS Traffic Engineering*.
+- [b-IETF RFC 4126] IETF RFC 4126 (2005), *Max Allocation with Reservation Bandwidth Constraints Model for Diffserv-aware MPLS Traffic Engineering & Performance Comparisons*.
+- [b-IETF RFC 4127] IETF RFC 4127 (2005), *Russian Dolls Bandwidth Constraints Model for Diffserv-aware MPLS Traffic Engineering*.
+- [b-IETF RFC 4206] IETF RFC 4206 (2005), *Label Switched Paths (LSP) Hierarchy with Generalized Multi-Protocol Label Switching (GMPLS) Traffic Engineering (TE)*.
+- [b-IETF RFC 4216] IETF RFC 4216 (2005), *MPLS Inter-Autonomous System (AS) Traffic Engineering (TE) Requirements*.
+- [b-IETF RFC 4301] IETF RFC 4301 (2005), *Security Architecture for the Internet Protocol*.
+- [b-IETF RFC 5470] IETF RFC 5470 (2009), *Architecture for IP Flow Information Export*.
+- [b-Charny 00] A. Charny and J.-Y. Le Boudec (2000), *Delay bounds in a network with aggregate scheduling* – First International Workshop of Quality of Future Internet Services (QOFIS2000).
+- [b-Le Boudec 01] J.-Y. Le Boudec and P. Thiran, *"Network Calculus – A Theory of Deterministic Queueing Systems for the Internet," Springer, LNCS vol. 2050, 2001*.
+- [b-Stiliadis 98] D. Stiliadis and A. Varma, *"Latency-Rate servers: A general model for analysis of traffic scheduling algorithms", IEEE/ACM Trans. Networking, vol. 6, no. 5 Oct. 1998*.
+- [b-Wang 04] Shengquan Wang; Dong Xuan; Bettati, R.; Wei Zhao, *Providing absolute differentiated services for real-time applications in static-priority scheduling networks*, IEEE/ACM Transactions on Networking, Volume 12, Issue 2, April 2004 Page(s): 326 – 339.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2205-201105-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ddc2d86595291397b6e9e8f6cbafc0364c5f7181
--- /dev/null
+++ b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bdd2ea26596b0a128c2e6f6216e4312884aa3acf2448cd3553f4604f94c06ead
+size 6552
diff --git a/marked/Y/T-REC-Y.2205-201105-I_PDF-E/9870bf462aa0d916a16d14b5a100c60a_img.jpg b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/9870bf462aa0d916a16d14b5a100c60a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c31b70b6dcd0273962cd3bc42ff84c8a8c14df50
--- /dev/null
+++ b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/9870bf462aa0d916a16d14b5a100c60a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:316b3702645a243c9c9e00d6befc4989af87e6d41d2216872f09ec97c12b8997
+size 52013
diff --git a/marked/Y/T-REC-Y.2205-201105-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6372e6d476ec28215b69091679c4d445d48ef4c4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dcd619a63907351438ccc66a5011ce1300ec1f8c880e9d160bfa9a997c7a2e95
+size 50653
diff --git a/marked/Y/T-REC-Y.2205-201105-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..56dcc2db8d92756a04b058762ce09389ee0ccc4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2205-201105-I_PDF-E/raw.md
@@ -0,0 +1,1294 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2205
+
+(05/2011)
+
+SERIES Y: GLOBAL INFORMATION INFRA-
+STRUCTURE, INTERNET PROTOCOL ASPECTS AND
+NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Service aspects: Service
+capabilities and service architecture
+
+# --- **Next Generation Networks – Emergency telecommunications – Technical considerations**
+
+Recommendation ITU-T Y.2205
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with two red lightning bolts striking it. To the right of the globe, the text "ITU" is written in a large, bold, blue font, and below it, the words "International Telecommunication Union" are written in a smaller, blue font.
+
+ITU logo: A blue globe with red lightning bolts and the text 'ITU International Telecommunication Union'.
+
+## ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+| | |
+|-----------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Smart ubiquitous networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| Future networks | Y.3000–Y.3099 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# **Recommendation ITU-T Y.2205**
+
+# **Next Generation Networks – Emergency telecommunications – Technical considerations**
+
+## **Summary**
+
+Recommendation ITU-T Y.2205 specifies technical considerations that can optionally be applied within the next generation network (NGN) to enable emergency telecommunications (ET). In addition, this Recommendation also outlines the underlying technical principles involved in supporting ET.
+
+## **History**
+
+| Edition | Recommendation | Approval | Study Group |
+|---------|----------------|------------|-------------|
+| 1.0 | ITU-T Y.2205 | 2008-09-12 | 13 |
+| 2.0 | ITU-T Y.2205 | 2011-05-20 | 13 |
+
+## **Keywords**
+
+Architecture, early warning (EW), emergency telecommunications, emergency telecommunications service (ETS), NGN, preferential telecommunications, priority telecommunications, QoS, telecommunications for disaster relief (TDR).
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2012
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|------------------------------------------------------------------------------------------------|------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| | 2.1 ITU-T..... | 1 |
+| | 2.2 IETF..... | 4 |
+| | 2.3 ETSI..... | 4 |
+| | 2.4 Broadband Forum..... | 4 |
+| 3 | Definitions ..... | 4 |
+| | 3.1 Terms defined elsewhere..... | 4 |
+| | 3.2 Terms defined in this Recommendation..... | 5 |
+| 4 | Abbreviations and acronyms ..... | 5 |
+| 5 | Emergency telecommunications (ET) and early warning description..... | 7 |
+| | 5.1 General ..... | 7 |
+| | 5.2 Emergency telecommunications..... | 8 |
+| | 5.3 Early warning ..... | 9 |
+| 6 | General considerations for emergency telecommunications and early warning ..... | 9 |
+| 7 | General functional requirements and capabilities..... | 10 |
+| | 7.1 Emergency telecommunications..... | 10 |
+| | 7.2 Early warning ..... | 11 |
+| 8 | General security guidelines and requirements..... | 12 |
+| | 8.1 General guidelines ..... | 12 |
+| | 8.2 General requirements..... | 12 |
+| 9 | Mechanisms and capabilities supporting emergency telecommunications in NGN .... | 13 |
+| | 9.1 General ..... | 13 |
+| | 9.2 Service stratum ..... | 18 |
+| | 9.3 Transport stratum..... | 20 |
+| | 9.4 NGN access technology support ..... | 22 |
+| 10 | End-to-end support for emergency telecommunications..... | 27 |
+| 11 | Mechanisms and capabilities supporting some aspects of early warning in NGN..... | 28 |
+| | 11.1 General ..... | 28 |
+| | 11.2 Common alerting protocol (CAP) ..... | 28 |
+| | 11.3 Procedures for the registration of arcs under the alerting object identifier arc ..... | 29 |
+| 12 | Service restoration priority ..... | 30 |
+| 13 | Protection switching and restoration ..... | 30 |
+| | 13.1 General considerations ..... | 30 |
+| | 13.2 SDH protection architectures ..... | 31 |
+| | 13.3 Optical transport network (OTN) ..... | 31 |
+
+| | Page |
+|----------------------------------------------------------------------|-------------|
+| 13.4 Ethernet linear protection switching..... | 31 |
+| 13.5 Ethernet ring protection switching ..... | 32 |
+| 13.6 Linear protection switching for transport MPLS (T-MPLS)..... | 32 |
+| 13.7 ATM protection switching ..... | 32 |
+| 13.8 Protection switching for MPLS networks ..... | 33 |
+| Appendix I – Emergency telecommunications categories..... | 34 |
+| I.1 Individual-to-authority emergency telecommunications..... | 34 |
+| I.2 Individual-to-individual emergency telecommunications..... | 34 |
+| I.3 Authority-to-authority emergency telecommunications..... | 34 |
+| I.4 Authority-to-individual emergency telecommunications..... | 35 |
+| Appendix II – Example use cases for early warning alert systems..... | 36 |
+| II.1 Push model ..... | 36 |
+| II.2 Pull model..... | 36 |
+| Appendix III – Example ETS call/session flows for NGN..... | 37 |
+| Bibliography..... | 39 |
+
+# Introduction
+
+[ITU-T Y.1271] provides the network requirements and capabilities for emergency telecommunications (ET). The realization of priority telecommunications based upon those requirements, as exemplified by authorities coordinating disaster relief using public networks, may result in the creation of new mechanisms and interworking reuse of existing mechanisms. Emergency telecommunications should be given preferential treatment over regular public network services. The term preferential telecommunications is used in some ITU-T Recommendations to include services that require priority treatment. Emergency telecommunications service is one category of services that is considered to have preferential treatment. The two terms, preferential telecommunications and emergency telecommunications are used interchangeably.
+
+Prioritized telecommunications used in emergency situations are not new; circuit-switched networks have supported such systems for years, primarily for voice calls (e.g., [ITU-T E.106]). However, the technical methods used to support these underlying requirements for emergency telecommunications in the NGN environment are evolving. Traditional circuit-switched priority methods do not necessarily apply in NGN due to inherent differences in circuit-switched versus packet-switched telecommunication.
+
+[ITU-T Y.1271] outlines the requirements and capabilities in general and abstract terms. [ITU-T Y.1271] is technology neutral.
+
+Since NGN is based on packet-switched technology, which is fundamentally different from circuit-switched technology, there is a need to consider the technical issues and potential solutions that could be used to effect the realization of emergency telecommunications capabilities in NGN.
+
+This Recommendation specifies technical considerations that may be applied within NGN to enable emergency telecommunications and the underlying principles involved.
+
+
+
+# Recommendation ITU-T Y.2205
+
+# Next Generation Networks – Emergency telecommunications – Technical considerations
+
+# 1 Scope
+
+This Recommendation specifies technical considerations that can optionally be applied within the next generation network (NGN) to enable emergency telecommunications (ET). In addition, this Recommendation also outlines the underlying technical principles involved in supporting ET. It specifies requirements and capabilities for ET beyond the ones specified in [ITU-T Y.2201] in the context of NGN (as defined in [ITU-T Y.2001] and further outlined in [ITU-T Y.2011]).
+
+Emergency telecommunications (including support of some aspects of early warning (see Figure 1)) include:
+
+- individual-to-authority emergency telecommunications, e.g., calls to emergency service providers;
+- authority-to-authority emergency telecommunications;
+- authority-to-individual emergency telecommunications, e.g., community notification services.
+
+Appendix I provides additional information for the above listed ET categories.
+
+Some requirements and capabilities for early warning are also specified. Individual-to-authority emergency telecommunications capabilities are not addressed and are outside the scope of this Recommendation.
+
+Some of the technical means described herein could also be used for individual-to-authority or individual-to-individual emergency telecommunications; however, these categories are not addressed in this Recommendation.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; all users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+## 2.1 ITU-T
+
+- | | |
+|-----------------|---------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T E.106] | Recommendation ITU-T E.106 (2003), International Emergency Preference Scheme (IEPS) for disaster relief operations. |
+| [ITU-T E.107] | Recommendation ITU-T E.107 (2007), Emergency Telecommunications Service (ETS) and interconnection framework for national implementations of ETS. |
+| [ITU-T G.808.1] | Recommendation ITU-T G.808.1 (2010), Generic protection switching – Linear trail and subnetwork protection. |
+| [ITU-T G.841] | Recommendation ITU-T G.841 (1998), Types and characteristics of SDH network protection architectures. |
+
+- [ITU-T G.842] Recommendation ITU-T G.842 (1997), *Interworking of SDH network protection architectures.*
+- [ITU-T G.873.1] Recommendation ITU-T G.873.1 (2006), *Optical Transport Network (OTN): Linear protection.*
+- [ITU-T G.983.1] Recommendation ITU-T G.983.1 (2005), *Broadband optical access systems based on Passive Optical Networks (PON).*
+- [ITU-T G.8031] Recommendation ITU-T G.8031/Y.1342 (2009), *Ethernet linear protection switching.*
+- [ITU-T G.8032] Recommendation ITU-T G.8032/Y.1344 (2010), *Ethernet ring protection switching.*
+- [ITU-T G.8131] Recommendation ITU-T G.8131/Y.1382 (2007), *Linear protection switching for transport MPLS (MPLS-TP) networks.*
+- [ITU-T H.248.1] Recommendation ITU-T H.248.1 (2005), *Gateway control protocol: Version 3.*
+- [ITU-T H.248.81] Recommendation ITU-T H.248.81 (2011), *Gateway control protocol: Guidelines on the use of the international emergency preference scheme (IEPS) call indicator and priority indicator in ITU-T H.248 profiles.*
+- [ITU-T H.323] Recommendation ITU-T H.323 (2009), *Packet-based multimedia communications systems.*
+- [ITU-T H.460.4] Recommendation ITU-T H.460.4 (2007), *Call priority designation and country/international network of call origination identification for H.323 priority calls.*
+- [ITU-T I.630] Recommendation ITU-T I.630 (1999), *ATM protection switching.*
+- [ITU-T J.260] Recommendation ITU-T J.260 (2005), *Requirements for preferential telecommunications over IP-Cablecom networks.*
+- [ITU-T J.261] Recommendation ITU-T J.261 (2009), *Framework for implementing preferential telecommunications in IP-Cablecom and IP-Cablecom2 networks.*
+- [ITU-T J.262] Recommendation ITU-T J.262 (2009), *Specifications for authentication in preferential telecommunications over IP-Cablecom2 networks.*
+- [ITU-T J.263] Recommendation ITU-T J.263 (2009), *Specification for priority in preferential telecommunications over IP-Cablecom2 networks.*
+- [ITU-T Q.812] Recommendation ITU-T Q.812 (2004), *Upper layer protocol profiles for the Q and X interfaces.*
+- [ITU-T Q.1741.6] Recommendation ITU-T Q.1741.6 (2009), *IMT-2000 references to Release 8 of GSM-evolved UMTS core network.*
+- [ITU-T Q.3303.3] Recommendation ITU-T Q.3303.3 (2008), *Resource control protocol No. 3 – Protocols at the Rw interface between a policy decision physical entity (PD-PE) and a policy enforcement physical entity (PE-PE): Diameter.*
+- [ITU-T Q.3321.1] Recommendation ITU-T Q.3321.1 (2010), *Resource control protocol No. 1, version 2 – Protocol at the Rs interface between service control entities and the policy decision physical entity.*
+- [ITU-T Q-Sup.57] ITU-T Q-series Recommendations – Supplement 57 (2008), *Signalling requirements to support the emergency telecommunications service (ETS) in IP networks.*
+
+- [ITU-T X.660] Recommendation ITU-T X.660 (2008) | ISO/IEC 9834-1:2008, *Information technology – Open Systems Interconnection – Procedures for the operation of OSI Registration Authorities: General procedures and top arcs of the International Object Identifier tree.*
+- [ITU-T X.674] Recommendation ITU-T X.674 (2011), *Procedures for the registration of arcs under the Alerting object identifier arc.*
+- [ITU-T X.1303] Recommendation ITU-T X.1303 (2007), *Common alerting protocol (CAP 1.1).*
+- [ITU-T Y.110] Recommendation ITU-T Y.110 (1998), *Global Information Infrastructure principles and framework architecture.*
+- [ITU-T Y.1271] Recommendation ITU-T Y.1271 (2004), *Framework(s) on network requirements and capabilities to support emergency telecommunications over evolving circuit-switched and packet-switched networks.*
+- [ITU-T Y.1541] Recommendation ITU-T Y.1541 (2006), *Network performance objectives for IP-based services.*
+- [ITU-T Y.1720] Recommendation ITU-T Y.1720 (2006), *Protection switching for MPLS networks.*
+- [ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN.*
+- [ITU-T Y.2011] Recommendation ITU-T Y.2011 (2004), *General principles and general reference model for Next Generation Networks.*
+- [ITU-T Y.2012] Recommendation ITU-T Y.2012 (2010), *Functional requirements and architecture of next generation networks.*
+- [ITU-T Y.2111] Recommendation ITU-T Y.2111 (2008), *Resource and admission control functions in next generation networks.*
+- [ITU-T Y.2171] Recommendation ITU-T Y.2171 (2006), *Admission control priority levels in Next Generation Networks.*
+- [ITU-T Y.2172] Recommendation ITU-T Y.2172 (2007), *Service restoration priority levels in Next Generation Networks.*
+- [ITU-T Y.2201] Recommendation ITU-T Y.2201 (2009), *Requirements and capabilities for ITU-T NGN.*
+- [ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1.*
+- [ITU-T Y.2702] Recommendation ITU-T Y.2702 (2008), *Authentication and authorization requirements for NGN release 1.*
+- [ITU-T Y.2704] Recommendation ITU-T Y.2704 (2010), *Security mechanisms and procedures for NGN.*
+- [ITU-T Y.2720] Recommendation ITU-T Y.2720 (2009), *NGN identity management framework.*
+- [ITU-T Y.2721] Recommendation ITU-T Y.2721 (2010), *NGN identity management requirements and use cases.*
+- [ITU-T Y.2722] Recommendation ITU-T Y.2722 (2011), *NGN identity management mechanisms.*
+
+## 2.2 IETF
+
+- [IETF RFC 2205] IETF RFC 2205 (1997), *Resource ReSerVation Protocol (RSVP) – Version 1 Functional Specification*.
+- [IETF RFC 3168] IETF RFC 3168 (2001), *The Addition of Explicit Congestion Notification (ECN) to IP*.
+- [IETF RFC 3246] IETF RFC 3246 (2002), *An Expedited Forwarding PHB (Per-Hop Behavior)*.
+- [IETF RFC 3261] IETF RFC 3261 (2002), *SIP: Session Initiation Protocol*.
+- [IETF RFC 3312] IETF RFC 3312 (2002), *Integration of Resource Management and Session Initiation Protocol (SIP)*.
+- [IETF RFC 3588] IETF RFC 3588 (2003), *Diameter Base Protocol*.
+- [IETF RFC 4340] IETF RFC 4340 (2006), *Datagram Congestion Control Protocol (DCCP)*.
+- [IETF RFC 4412] IETF RFC 4412 (2006), *Communications Resource Priority for the Session Initiation Protocol (SIP)*.
+- [IETF RFC 4542] IETF RFC 4542 (2006), *Implementing an Emergency Telecommunications Service (ETS) for Real-Time Services in the Internet Protocol Suite*.
+- [IETF RFC 4594] IETF RFC 4594 (2006), *Configuration Guidelines for DiffServ Service Classes*.
+- [IETF RFC 5865] IETF RFC 5865 (2010), *A Differentiated Services Code Point (DSCP) for Capacity-Admitted Traffic*.
+
+## 2.3 ETSI
+
+- [ETSI TS 183 017] ETSI TS 183 017 V3.2.1 (2010), *TISPAN Resource and Admission Control: DIAMETER protocol for session based policy set-up information exchange between the Application Function (AF) and the Service Policy Decision Function (SPDF); Protocol specification*.
+
+## 2.4 Broadband Forum
+
+- [BBF TR-058] Broadband Forum TR-058 (2003), *Multi-Service Architecture and Framework Requirements*.
+- [BBF TR-059] Broadband Forum TR-059 (2003), *DSL Evolution – Architecture Requirements for the Support of QoS-Enabled IP Services*.
+- [BBF TR-101] Broadband Forum TR-101 (2011), *Migration to Ethernet-Based DSL Aggregation*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 alert** [ITU-T X.674]: A warning or alarm message concerning an impending danger or problem.
+
+**3.1.2 alerting agency** [ITU-T X.674]: A national, regional or international entity responsible for the management of alerts.
+
+**3.1.3 emergency telecommunications service (ETS)** [ITU-T E.107]: A national service providing priority telecommunications to the ETS authorized users in times of disaster and emergencies.
+
+**3.1.4 next generation network (NGN)** [ITU-T Y.2001]: A packet-based network able to provide telecommunication services and able to make use of multiple broadband, QoS-enabled transport technologies and in which service-related functions are independent from underlying transport-related technologies. It enables unfettered access for users to networks and to competing service providers and/or services of their choice. It supports generalized mobility which will allow consistent and ubiquitous provision of services to users.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 emergency telecommunications (ET)**: ET means any emergency related service that requires special handling from the NGN relative to other services. This includes government authorized emergency services and public safety services.
+
+**3.2.2 preferential telecommunications**: A category of services for which premium access to, and/or use of telecommunications network resources is provided.
+
+**3.2.3 telecommunications for disaster relief (TDR)**: TDR is an international and national telecommunications capability for purposes of disaster relief. It can make use of international permanent, shared network facilities already in place and operational, temporary network facilities that are provisioned specifically for TDR, or a suitable combination of the two.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations:
+
+| | |
+|-------|-----------------------------------------------|
+| AAA | Authentication, Authorization, and Accounting |
+| AF | Application Function |
+| ANMS | Access Node Management System |
+| APS | Automatic Protection Switching |
+| AQM | Active Queue Management |
+| ASN | Access Service Network |
+| ASN.1 | Abstract Syntax Notation One |
+| BNG | Broadband Network Gateway |
+| BS | Base Station |
+| CAC | Call Admission Control |
+| CAP | Common Alerting Protocol |
+| CPE | Customer Premises Equipment |
+| DCCP | Data Congestion Control Protocol |
+| DoS | Denial of Service |
+| DSCP | Diff-Serv Code Points |
+| DSLAM | Digital Subscriber Line Access Multiplexer |
+| EAS | Emergency Alert System |
+| ECN | Explicit Congestion Notification |
+
+| | |
+|----------|-------------------------------------------------|
+| EF | Expedited Forwarding |
+| E-MTA | Embedded Multi-Terminal Adapter |
+| ENI | ETS National Implementation |
+| ET | Emergency Telecommunications |
+| ETH | Ethernet Layer Network |
+| ETS | Emergency Telecommunications Service |
+| EW | Early Warning |
+| GETS | Government Emergency Telecommunications Service |
+| IEPS | International Emergency Preference Scheme |
+| IP | Internet Protocol |
+| ISDN | Integrated Services Digital Network |
+| LAN | Local Area Network |
+| LSP | Label Switched Path |
+| MDF | Main Distribution Frame |
+| MMPS | Multimedia Priority Service |
+| MPS | Multimedia Priority Service |
+| MPLS | MultiProtocol Label Switching |
+| MS | Multiplex Section |
+| NID | Network Interface Device |
+| NOAA | National Oceanic and Atmospheric Administration |
+| NGN | Next Generation Network |
+| ODUk | Optical channel Data Unit k |
+| OLT | Optical Line Termination |
+| OMCI | ONT Management and Control Interface |
+| ONT | Optical Network Termination |
+| OTN | Optical Transport Network |
+| P-CSC-FE | Proxy Call Session Control Functional Entity |
+| PCC | Policy and Charging Control |
+| PDP | Policy Decision Point |
+| PEP | Policy Enforcement Point |
+| PF | Policy Function |
+| PHB | Per Hop Behaviour |
+| PIN | Personal Identification Number |
+| PLMN | Public Land Mobile Network |
+| PON | Passive Optical Network |
+| POTS | Plain Old Telephone Service |
+| PSAP | Public Safety Answering Point |
+
+| | |
+|---------|--------------------------------------------------------------|
+| PSTN | Public Switched Telephone Network |
+| RACF | Resource and Admission Control Function |
+| RPH | Resource Priority Header |
+| RSVP | Resource ReSerVation Protocol |
+| QoS | Quality of Service |
+| SAME | Specific Area Message Encoding |
+| SCF | Service Control Function |
+| SDH | Synchronous Digital Hierarchy |
+| SIP | Session Initiation Protocol |
+| SLA | Service Level Agreement |
+| SNC | SubNetwork Connection |
+| SNCP | SubNetwork Connection Protection |
+| SS7 | Signalling System No.7 |
+| TCP | Transmission Control Protocol |
+| TDM | Time Division Multiplexing |
+| TDR | Telecommunications for Disaster Relief |
+| T-MPLS | Transport MPLS |
+| UDP | User Datagram Protocol |
+| UE | User Equipment |
+| UN/ISDR | United Nations International Strategy for Disaster Reduction |
+| USI | Universal Services Interface |
+| VC | Virtual Channel |
+| VLAN | Virtual LAN |
+| VoIP | Voice over IP |
+| VP | Virtual Path |
+| W-CDMA | Wideband Code Division Multiple Access |
+| WPS | Wireless Priority Service |
+| xDSL | Any variant of Digital Subscriber Line |
+| XML | eXtensible Markup Language |
+| XSD | XML Schema Definition |
+
+# **5 Emergency telecommunications (ET) and early warning description**
+
+## **5.1 General**
+
+The following terms are used in this Recommendation:
+
+- emergency telecommunications ET
+- emergency telecommunications service ETS
+
+- telecommunications for disaster relief TDR
+- early warning EW
+
+It is essential that the different uses of these terms are agreed and understood. To that end, the following terms are used in the following manner:
+
+- ET: The umbrella term for any emergency-related service that requires special handling from the NGN relative to other services.
+- ETS: The term is used as defined in [ITU-T E.107].
+- TDR: The generic term for a telecommunications capability used for the purposes of disaster relief.
+- EW: The generic term for all types of early warning systems, capabilities and services.
+
+This arrangement forms a tree with ET at the root for all activities. The use of terms and their inter-relationships is shown in Figure 1 below.
+
+As noted in the introduction, some ITU-T Recommendations, specifically the ITU-T J.26x-series uses the term preferential telecommunications to include services that require special handling relative to other services. Except in the context of J.26x-series of ITU-T Recommendations, the term preferential telecommunications is not referenced in this Recommendation. The term preferential telecommunications in ITU-T J.26x-series of Recommendations includes ETS, TDR and EW.
+
+
+
+```
+
+graph TD
+ ET["Emergency telecommunications (ET)*"]
+ ET --- I2A["Individual-to-authority"]
+ ET --- A2A["Authority-to-authority**"]
+ ET --- A2I["Authority-to-individual"]
+ A2A --- IC["International capabilities
+(Subject to ITU-T Recommendations)"]
+ A2A --- NC["National capabilities
+(Not subject to ITU-T Recommendations)"]
+ IC --- TDR["Telecommunications for
+disaster relief (TDR)"]
+ IC --- ETS_N["Interconnection of ETS
+national implementations"]
+ NC --- ETS["Emergency telecommunications
+service (ETS)"]
+ NC --- OS["Other services
+(e.g., public safety services)"]
+
+```
+
+A hierarchical tree diagram showing the terminological relationship framework for emergency telecommunications (ET). The root is 'Emergency telecommunications (ET)\*'. It branches into three categories: 'Individual-to-authority', 'Authority-to-authority\*\*', and 'Authority-to-individual'. The 'Authority-to-authority\*\*' category further branches into 'International capabilities (Subject to ITU-T Recommendations)' and 'National capabilities (Not subject to ITU-T Recommendations)'. 'International capabilities' branches into 'Telecommunications for disaster relief (TDR)' and 'Interconnection of ETS national implementations'. 'National capabilities' branches into 'Emergency telecommunications service (ETS)' and 'Other services (e.g., public safety services)'.
+
+\* Including some aspects of early warning
+
+\*\* May also apply to authority-to-individual telecommunications
+
+Y.2205(11)\_F01
+
+**Figure 1 – Terminological relationship framework for emergency telecommunications**
+
+## 5.2 Emergency telecommunications
+
+Emergency telecommunications (ET) means any emergency-related service that requires special handling from the NGN relative to other services. This includes government authorized emergency services and public safety services. The following are specific example services under the umbrella of emergency telecommunications:
+
+### 1) Telecommunications for disaster relief (TDR)
+
+TDR is an international and national telecommunications capability for the purpose of disaster relief. It can make use of international permanent, shared network facilities already in place and operational, temporary network facilities that are provisioned specifically for TDR, or a suitable combination of the two.
+
+### 2) Emergency telecommunications service (ETS)
+
+ETS is a national service, providing priority telecommunications to ETS authorized users in times of disaster and emergencies. The description of ETS is specified in [ITU-T E.107]. [ITU-T E.107] provides guidance that will enable telecommunications between one ETS national implementation (ENI) and other ENI(s) (authority-to-authority).
+
+### 3) National/Regional/Local emergency and public safety services
+
+Other examples of ET are national, regional, local emergency and public safety services. These are specialized services for national, regional, local emergencies and public safety. These emergency services are national, regional, or local specific and are subject to national or regional standardization.
+
+## 5.3 Early warning
+
+The United Nations International Strategy for Disaster Reduction (UN/ISDR) in a September 2006 report [b-UN Global Survey] to the United Nations Secretary General on "A Global Survey of early warning Systems" defines early warning as "the provision of timely and effective information, through identified institutions, that allows individuals exposed to a hazard to take action to avoid or reduce their risk and prepare for effective response". This UN report provides an assessment of capabilities, gaps, and opportunities towards building a comprehensive global early warning system for all natural hazards.
+
+# 6 General considerations for emergency telecommunications and early warning
+
+Prior to the development of [ITU-T Y.1271], the requirements for emergency telecommunications capabilities primarily related to circuit-switched networks such as the public switched telephone network (PSTN).
+
+These requirements were based on and took advantage of certain characteristics of circuit-switched networks. For example:
+
+- admission control utilizing a tight coupling between signalling and media resources;
+- all media traffic requiring uniform bandwidth delivered at a constant bit rate;
+- per flow reserved bandwidth;
+- separation of control and data traffic.
+
+These characteristics are not necessarily found in current best-effort packet-switched networks where:
+
+- packet-switched networks tend to rely on sharing resources and using queues to help compensate for bursty traffic – the combination generally realized as best-effort service.
+- admission control may be difficult – many applications do not signal their bandwidth requirements, and there is a decoupling of signalling and media;
+- applications and services have variable bandwidth requirements and may send data using dynamically adjusted rates;
+- different packet flows share statistically multiplexed bandwidth;
+- resource control and data traffic may share the same resources in the network.
+
+In packet-switched NGN, packets may still contend for available bandwidth, unless special measures are applied. At a pure transport level, packets cannot easily be refused or flow-controlled. Additionally, traffic engineering of a packet-based network is significantly different from a circuit-switched network with regard to standard and universally accepted approaches. A given "flow" of packets can be affected by other flows of packets using a shared resource, unless special measures available in an NGN are utilized appropriately. On the other hand, the separation between
+
+service and transport in an NGN may be advantageous for the provisioning of more flexible and diverse emergency capabilities.
+
+These conditions mean that the provisioning of emergency telecommunication capabilities is not entirely straightforward, obvious or simple, nor can simple transposition from the circuit-switched world be affected. Other detailed differences between circuit-switched and packet-switched networks, and between different packet technologies, will affect the provisioning and fulfilment of the various requirements specified in [ITU-T Y.1271].
+
+Thus, the intent of this Recommendation is to indicate the features and mechanisms of an NGN that may be used to facilitate the requirements of emergency telecommunications and some aspects of early warning. However, in considering the protocols, mechanisms and support for emergency telecommunications, it is desirable to avoid introducing features or requirements, though useful, as they may add complexity without significant benefit. Care must be taken by taking into account the overhead incurred in resource consumption and other effects before adding, for example, new features for "priority".
+
+# **7 General functional requirements and capabilities**
+
+Functional requirements and capabilities include those specified in [ITU-T Y.1271] and [ITU-T Y.2201] for NGN, and in addition those detected from the UN Global Survey on Early Warning Systems with relevance to NGN development [b-UN Global Survey].
+
+## **7.1 Emergency telecommunications**
+
+Table 1 lists the emergency telecommunications functional requirements and capabilities.
+
+**Table 1 – Emergency telecommunications functional requirements and capabilities list**
+
+| Emergency telecommunications functional requirements and capabilities |
+|------------------------------------------------------------------------------------------------------------|
+| Enhanced priority treatment |
+| Secure networks |
+| Location confidentiality |
+| Restorability |
+| Network connectivity |
+| Interoperability |
+| Mobility |
+| Ubiquitous coverage |
+| Survivability/endurability |
+| Real-time transmission to support: voice/real-time text and video/imagery(where bandwidth is available) |
+| Non-real-time transmission to support: messages/non-real-time streams (audio/video) |
+| Scalable bandwidth |
+| Reliability/availability |
+
+The goal is to provide high confidence and probability that critical telecommunications will be available to perform reliably for authorized users, such as those involved in emergency telecommunications. [ITU-T Y.1271] provides "Framework(s) on network requirements and
+
+capabilities to support emergency telecommunications over evolving circuit-switched and packet-switched networks".
+
+With respect to video and imagery, bandwidth (e.g., a form of resource) availability should be taken into consideration.
+
+Emergency telecommunications specific network functions can be divided into the following categories: service invocation, authentication and authorization, end-to-end priority treatment, network interconnection and protocol interworking.
+
+A service invocation pertains to user interaction with the user element (e.g., telephone) and the network with information that indicates an emergency telecommunications service request to the service provider network. There are different approaches including subscription arrangements for recognizing the request. Subscription information is used to authorize some service requests.
+
+Authentication and authorization is performed by the service provider to allow or deny the user access to the invoked service for emergency telecommunications. The authorization itself is expected to occur at the core network.
+
+End-to-end priority treatment is a set of capabilities used by the network(s) in providing high probability in establishing and maintaining the service from the originating network to the terminating network including any transit networks. The priority treatment persists with the service invocation to release of the service. The priority treatment is included in admission control and allocation of network resources, and transport of signalling and media bearer packets by the network elements supporting the service.
+
+Network interconnection and protocol interworking is necessary for supporting end-to-end priority treatment for signalling and media transport traversing multiple networks belonging to different providers using different technologies. As an example, the levels of priority may vary depending on the technology used in the multiple networks and mapping from a level defined in one technology to another may be required.
+
+## **7.2 Early warning**
+
+Early warning systems need an effective communication system that is reliable and robust. Some objectives for early warning systems in the context of the NGN as the communication system are to:
+
+- have continuously operating capabilities and be operational, robust, available every minute of every day;
+- provide the needed telecommunication capabilities to transmit real-time (e.g., seismic and sea-level data information);
+- be based on internationally agreed standards;
+- ensure the integrity of early warning systems and the integrity and authenticity of messages (i.e., that only authorized messages are sent);
+- provide warning messages only to those possibly affected by an impending disaster and prevent untargeted and unnecessary messages. (e.g., messages sent to the wrong people and/or messages that do not contain useful viable information).
+
+In order to provide warning messages only to those possibly affected by an impending disaster, early warning systems may have objectives related to the filtering of messages so that these reach a selected:
+
+- group of users;
+- region or geographical area, etc.
+
+(e.g., a form of "cell broadcasting")
+
+# **8 General security guidelines and requirements**
+
+## **8.1 General guidelines**
+
+The network elements, systems, resources, data, and services used to support emergency telecommunications can be targeted for cyber attacks. The integrity, confidentiality, and availability of emergency telecommunications, especially when under attack, will depend on the security services and practices implemented in the NGN and on the security capabilities (e.g., user authentication and authorization functions) implemented as part of the application service for emergency telecommunications. General guidelines to consider for emergency telecommunications security planning include (but are not limited to):
+
+- All aspects of emergency telecommunications including the signalling and control, bearer/media, and management-related data and information (e.g., user profile information) need to be protected against security threats. Security threats to emergency telecommunications could occur at various layers (e.g., transport, service control or service support) and in the different network segments (i.e., access, core network, and interconnection interfaces).
+- Establishment and enforcement of security policies and practices that are specific to emergency telecommunications services. Mitigation capabilities to provide protection against various security threats should be identified and implemented. Specifically, mitigation capabilities and security practices beyond those needed for general application services should be identified and implemented for emergency telecommunications. This includes security policies to protect management data and stored information (e.g., user profile information) related to emergency telecommunications.
+- Implementation and use of procedures to authenticate and authorize users, devices or the combination of user and device to protect against unauthorized access to services, resources and information (e.g., user information in authentication servers and management systems) associated with emergency telecommunications. For example, authentication and authorization functions should be implemented to prevent use of resources dedicated to emergency telecommunications by unauthorized users in order to prevent denial of service (DoS) and other types of attack.
+- Responsibility within each network for security within its domain for communications that traverse multiple network provider domains so that the end-to-end communication can be secured. Since emergency telecommunications may involve communications that traverse different network provider domains of national and international networks (i.e., countries and administrations), security policy, trust relations, methods and procedures for identifying emergency telecommunications traffic, identity management and authentication of users and networks across multiple network administration domains need to be established and implemented.
+
+Additional information can be found in [b-ATIS-1000010].
+
+## **8.2 General requirements**
+
+The security recommendations in [ITU-T Y.2701], [ITU-T Y.2702], and [ITU-T Y.2704], and the identity management (IdM) recommendations in [ITU-T Y.2720], [ITU-T Y.2721], and [ITU-T Y.2722] are relevant to emergency telecommunications security.
+
+### **8.2.1 Access control**
+
+Only authorized users must be allowed access to emergency telecommunications and any associated resources. Any unauthorized access, such as that by intruders masquerading as authorized users, must be prevented.
+
+### **8.2.2 Authentication**
+
+Mechanisms and capabilities to identify, authenticate and authorize access of the emergency telecommunications user, device or user and device combination as applicable based on policy1 and the assurance level for specific service (e.g., voice, data, video) is necessary for security protection.
+
+### **8.2.3 Confidentiality and privacy**
+
+Confidentiality and privacy protection of emergency telecommunications and end-user information are necessary. This includes confidentiality and privacy protection of emergency telecommunications signalling, control and bearer traffic, end-user information (e.g., identity, subscription and location information) and activity, as applicable.
+
+### **8.2.4 Communication security**
+
+Protection of emergency telecommunications against intrusions is necessary (e.g., prevention of unlawful interception, hijacking or replay of signalling or bearer traffic).
+
+### **8.2.5 Data integrity**
+
+Integrity protection of emergency telecommunications is necessary (e.g., protection against unauthorized modification, deletion, creation, or replay). This includes integrity protection of emergency telecommunications information and any configuration data (e.g., priority marking, priority information stored in policy decision functions, user priority level, etc.).
+
+### **8.2.6 Availability**
+
+Availability of emergency telecommunications must be protected. Specifically, emergency telecommunications and any associated resources must be protected against denial of service (DoS) and other forms of attacks.
+
+# **9 Mechanisms and capabilities supporting emergency telecommunications in NGN**
+
+## **9.1 General**
+
+The separation of service/application control from transport, which allows both application services and transport services to be offered separately and to evolve independently, is a key characteristic of NGN. This separation takes the form of two distinct blocks or strata of functionality. The transport functions reside in the transport stratum and the service control functions related to applications, such as telephony, reside in the service stratum. In general, each stratum will have its own set of roles, players and administrative domains (see [ITU-T Y.110]. The roles involved in service(s) provisioning are independent from those involved in transport connectivity provisioning. Each stratum can be treated separately from a technical point of view. The resource and admission control functions (RACF) is the arbitrator between these strata for QoS-related reservation (and negotiation) in the NGN architecture. [ITU-T Y.2111] specifies the functional architecture and requirements for the resource and admission control functions in next generation networks, which may involve a variety of access and core transport technologies and multiple domains. The RACF QoS-related decisions are based upon SLAs, service priority, user profiles, network operator policy rules and resource availability for both access and core networks. Emergency telecommunications users are required to be identified and given priority for admission control by the RACF once authenticated and authorized.
+
+---
+
+1 Policy in this context includes all applicable policies such as those generated from NGN provider decisions, regulatory requirements, or other governmental rules.
+
+If emergency telecommunications traffic is to be distinguished from normal traffic within the NGN, then appropriate distinguishing labels, also known as markers, are required to be available. The term (traffic) marking is used in this context.
+
+In the edge-to-edge (i.e., access and core network segments) multi-layered (i.e., transport and service strata) NGN protocol architecture, labels may exist in various forms at the different protocol layers both vertically (i.e., interactions between different protocol layers) and horizontally (i.e., interactions between communicating network elements). Labels can be carried in signalling packets, and/or included within the header of a data packet to identify and mark emergency telecommunication calls or sessions. The labels used to identify and mark emergency telecommunications calls or sessions and/or traffic are protocol specific. To achieve specialized (e.g., priority or preferential) treatment end-to-end for all aspects of the emergency telecommunication call or session (i.e., call/session control, bearer traffic and management), appropriate mapping and interworking between the labels used in the different protocols are required. For example, the SIP resource priority header information used in the control layer to identify the priority call or session could be mapped to the appropriate diff-serv code points (DSCPs) to mark the emergency telecommunications traffic in the IP network layer. Similarly, the diff-serv code points (DSCPs) at layer 3 could be mapped to the specific VLANs or Ethernet priority parameters at layer 2 in the transport protocol. SIP is specified in [IETF RFC 3261] and its updates [b-IETF RFC 3265], [b-IETF RFC 3853], [b-IETF RFC 4320], [b-IETF RFC 4916], [b-IETF RFC 4032], and [b-IETF RFC 5027].
+
+In the service stratum, services tend to use a specific and designated set of protocols. Thus, the techniques that can be leveraged for specific emergency telecommunications services will vary according to the services under consideration and the capabilities of the particular service-related protocols in question.
+
+In the transport stratum, the Internet Protocol (IP) may be used. The IP version used may vary from one provider to another and the end-to-end connectivity may require adapting different versions by using, for example, tunneling one version within another. However, this should not impact the transport of emergency telecommunications service-related information.
+
+Furthermore, the protocols used in local (last-mile) access infrastructures may be different from those used in core infrastructures. Local access infrastructures could be wired (i.e., fixed access), wireless, or a combination of these two technologies.
+
+Thus, a given end-to-end path for an emergency telecommunications call or session can traverse a wide range of transport technologies.
+
+Later clauses will outline the various features and capabilities of particular technologies that can be leveraged to facilitate the requirements of emergency telecommunications.
+
+Since the transport stratum may use the IP (and a number of related protocols), and transport protocols defined by the IETF, it is prudent to utilize applicable IETF-defined capabilities in respect of its usage for the support of emergency telecommunications, as applicable. These will be discussed in later clauses.
+
+It is important to make a distinction between the specifications (RFCs) developed by the IETF, and their deployment in the Internet, and an NGN context. In both cases, the actual specifications used will depend on what the particular provider concerned has deployed. However, since the Internet is outside the scope of ITU-T, no assumptions can be made about the quality of service or capabilities of Internet-based paths, as explained in [b-IETF RFC 4190]2 . On the other hand, more stringent requirements for international emergency telecommunications in IP-based NGNs are within the scope of ITU-T and may be proposed in ITU-T Recommendations for use by NGN providers.
+
+[IETF RFC 4542] describes possible solutions for the "Internet Emergency Preference Service". Many of the concepts outlined therein apply to ETS in the context of NGN.
+
+In an NGN where the service and transport stratum are independent, the following factors influence the success of an emergency telecommunication:
+
+- i) identification and marking of the emergency telecommunication traffic;
+- ii) admission control policy;
+- iii) bandwidth allocation policy;
+- iv) authentication and authorization of bona fide emergency telecommunications users.
+
+### **9.1.1 Priority treatment**
+
+In general, priority treatment is the key to providing emergency telecommunications, which by definition have to be considered more important than ordinary telecommunication services. When ordinary services consume the vast majority of finite network resources, emergency telecommunications are forced to compete for these same finite resources, and can be adversely affected. Therefore, some means of giving priority treatment for emergency services over ordinary telecommunication services should be devised. Primarily, this means:
+
+- a) recognizing the authorized emergency telecommunications users;
+- b) granting the authorized emergency telecommunications users service priority.
+
+In the layered NGN architecture as defined in [ITU-T Y.2012], the priority indicator sent from the service control functions (SCF) to the resource and admission control functions (RACF) should be capable of indicating priority levels associated with the users to allow different policies to be implemented and differentiation between multiple types of priority applications. For example, hospital personnel might be provided a user priority level below that of critical emergency relief coordinators.
+
+### **9.1.2 Identification, authentication and authorization, and access control**
+
+It is necessary to prevent unauthorized access to services and resources for emergency telecommunications, such as by intruders masquerading as authorized users. Therefore, mechanisms and capabilities to authenticate and authorize access of emergency telecommunications users, devices or user and device combinations as applicable, based on policy for specific service (e.g., ETS and TDR), are required to be supported.
+
+It is necessary to identify emergency telecommunications call or session requests (e.g., by specialized dialling, input, user or subscription profiles). NGN providers should expedite the authentication of authorized emergency telecommunications users. Specific mechanisms and
+
+---
+
+2 [b-IETF RFC 4190] states:
+
+"A constant fixture in the evolution of the Internet has been the support of Best Effort as the default service model"
+
+and;
+
+"inter-domain ETS communications should not rely on ubiquitous or even widespread support along the path between the end points."
+
+methods are required to be used for authentication and authorization based on policy for specific emergency telecommunications (e.g., use of personal identification number (PIN), and user and subscription profiles).
+
+Example approaches for ETS authentication and authorization are described in Appendix II of [ITU-T Y.2702] and include:
+
+- a) Use of personal identification number (PIN): This approach uses a PIN to authenticate the user's authorization to invoke ETS. This approach identifies the user and not the user's device. Therefore, it is normally used in cases where the user is allowed to invoke ETS from any device.
+- b) Use of subscription/service profile: In this approach, the user device and service profile is provisioned to indicate ETS subscription. When the user device is authenticated as part of the NGN provider (i.e., ETS provider) normal registration and authentication procedures, the user's ETS subscription is identified. When a user initiates an ETS request, the check against the user's service profile determines whether the user device is authorized for the ETS.
+- c) Use of PIN and service profile combination: These approaches combine the PIN and service profile methods and may be used to concurrently authenticate both the user and the user device to provide higher levels of assurance for ETS.
+- d) Use of special security tokens and biometrics: In addition to the approaches described above, more sophisticated approaches using special security tokens and biometric capabilities to authenticate and authorize ETS users and terminals may be used to provide a higher level of identity assurances.
+
+Once the user, user device or user and device combination is authenticated and authorized based on the applicable policy, the emergency telecommunications call or sessions are required to be marked and indicated in the forward direction to subsequent networks. Also, once authenticated and authorized, priority is required to be given to all aspects of the emergency telecommunications call/session, the signalling/control, the bearer traffic, and any applicable management.
+
+Authentication and authorization consideration are also necessary to the handing off and receiving of emergency telecommunications calls or sessions between NGN providers, taking into account a multi-provider environment and separation of service control and transport. Authentication and authorization of NGN providers for handing off and receiving emergency telecommunications calls/session and traffic should be based on the SLAs and applicable policy.
+
+IdM capabilities ([ITU-T Y.2720], [ITU-T Y.2721], and [ITU-T Y.2722]) can be leveraged to provide increased confidence in identity information for emergency telecommunications applications. Appendix III of [ITU-T Y.2721] provides ETS-related IdM use case examples. These use case examples describe how IdM capabilities can be used to support ETS applications and cover the following topics:
+
+- Authentication assurance using device and user combination (e.g., correlation of user and device authentication).
+- Enhanced authentication of ETS users for next generation priority services (e.g., use of tokens, digital certificates, voice recognition and biometrics).
+- Authentication of called party and data communication sources (e.g., assurance of messages and data sources).
+- Identification and authentication of service providers in a multi-provider environment (e.g., identification of access, content and network service providers).
+- Single sign-on and single sign-off (e.g., access to multiple application without having to provide credentials individually for each application).
+
+### 9.1.3 Admission control considerations for higher probability of admission
+
+One of the functions of the resource and admission control function (RACF) is supporting QoS control to include resource admission and resource reservation, if desired, by the service provider. As such, during times of high service demand from users, some service requests may need to be denied. If these denials do not occur, then the NGN may not fully guarantee service quality in emergency cases. The RACF QoS-related processes involve authorization based on user profiles, SLAs, operator specific policy rules, service priority, and resource availability within access and core transport. This Recommendation postulates that RACF should have the capability to prioritize service requests using service priority. (A network that simply denied authorized requests due to momentary congestion would lead to poor customer service if customers were repeatedly forced to re-submit requests.) Therefore, this Recommendation asserts that service priority is a primary factor to be considered by the scheduling method for the resource allocation queue/general admission decision. Mechanisms to enable this functionality are discussed below.
+
+The high-level requirements of the RACF are to operate on authorized requests for QoS using user profiles and priority. One specific requirement is for admission control to make use of the service priority information for priority handling. There are various methods that can be used for resource-based admission control service priority.
+
+One possible method is that a higher admission threshold be provided for emergency telecommunications traffic, thus allowing some additional admission for priority requests when regular requests are being denied. In effect, this method temporarily increases utilization of network resources. However, because of the large amount of NGN resources and the fact that in any appreciable time interval, some resources will naturally become available (e.g., as other sessions compete), the system will be restored to its intended operational day-to-day traffic capability. Furthermore, assuming that the amount of priority traffic is relatively small and networks seldom, if ever, operate at full 100 percent capacity, it becomes clear that the higher threshold of the admission decision for priority traffic should not pose any danger to the overall network health or QoS of other traffic.
+
+There are reservation-based admission control systems that allow a service request only when the request for required bandwidth is successful. In this case, the method of servicing the scheduling mechanisms should consider service priority as a primary consideration.
+
+Finally, other mechanisms to bypass admission control mechanisms are also possible (e.g., priority traffic bypassing RACF). An example of such a mechanism is currently being written within IETF.
+
+#### 9.1.3.1 Call admission control (CAC)
+
+CAC is a set of actions and policies taken by the network at the call or session set-up phase in order to accept or reject a service based on requested performance and priority criteria, and the availability of necessary resources.
+
+In a traditional PSTN/ISDN, call admission control simply means whether a circuit is granted or not based on the authorization. Furthermore, allocation of a circuit by definition implies the availability of a path with the required bandwidth. Due to the availability of network state information regarding the status of individual circuits (voiceband channels), a PSTN/ISDN network can:
+
+- a) divert emergency calls to paths specifically reserved for emergency traffic (if available);
+- b) wait for a circuit to be available (trunk queuing).
+
+Since no discrete paths or circuit state information exist in IP-based networks, authentication and authorization at the ingress to the network alone cannot ensure availability of an end-to-end path or sufficient end-to-end bandwidth for a given call or session. In an IP-based network, an ingress network element has no or little knowledge of prevailing network conditions outside its domain. Therefore, CAC at an ingress network element is insufficient to ensure availability of an end-to-end path unless augmented by additional mechanisms.
+
+A further implication is that an egress network element has no control over or knowledge of the remote ingress network element that may be attempting to establish a call or session to it. However, in a PSTN/ISDN an egress network element is able to control a potential ingress network element, attempting to establish a call/session, via the associated signalling mechanisms.
+
+[ITU-T Y.2171] specifies admission control priority for telecommunications services seeking entry into a network particularly during emergency conditions when network resources may be depleted. In particular, it recommends three levels for admission control priority for services seeking entry into NGN. Priority level 1 (highest) is recommended for emergency telecommunications (including ETS) over NGN. Traffic with this priority level receives the highest priority for admission to the NGN.
+
+## **9.2 Service stratum**
+
+### **9.2.1 General**
+
+Countries have, or are developing, ETS to allow priority treatment for authorized traffic to support emergency and disaster relief operations within their national boundaries. However, there could be a crisis situation where it is important for an ETS user in one country to communicate with users in another country. In this case, it is important for an ETS call or session which originated in one country to receive end-to-end priority treatment, i.e., priority treatment in the originating country and the destination country. This may require interconnection of two ETS national implementations via an international network that either provides priority treatment capabilities, or convey the priority transparently between both countries.
+
+The following clauses outline a number of protocol mechanisms used to signal and obtain priority treatment at the service control level in the context of a packet-based NGN. Specific applicability of these protocol mechanisms to ETS are also highlighted. These protocol capabilities are needed for international applications in the context of communications between national ETS implementations via the international network (e.g., interconnection of two ETS national implementations).
+
+### **9.2.2 SIP resource priority**
+
+[IETF RFC 4412] adds two header fields to SIP, namely the Resource-Priority and the Accept-Resource-Priority fields, and specifies the procedures for their usage. The 'Resource-Priority' header field may be used by SIP user agents, including public switched telephone network (PSTN) gateways and terminals, and SIP proxy servers to influence their treatment of SIP requests.
+
+To provide equivalence to some existing systems, priority appropriate to several different "standardized" systems can be accommodated by identifying the "namespace" appropriate to the particular system and the number of priority levels within that system. The following namespaces and the associated number of priority levels are identified in [IETF RFC 4412] for use in ETS.
+
+| Namespace | Levels |
+|-----------|--------|
+| ets | 5 |
+| wps | 5 |
+
+All ETS calls/sessions in IP environments are designated with an "ets" namespace with five priority levels that convey levels of importance in the application layer (within SIP elements). Incoming ETS calls or sessions are assigned the "ets" designation in the 'Resource-Priority' header. ETS calls/sessions are recognized by the presence of the "ets" namespace 'Resource-Priority' header value in the SIP message and accorded the "High" priority for resource reservation/assignment such that preferential treatment can be enacted in the transport layer. A similar namespace designation of "wps" accompanied by five priority levels is available for call or session allocations where resources are limited or congested, such as in radio access for wireless networks.
+
+### 9.2.3 IEPS
+
+[ITU-T E.106] describes the functional requirements, features, access and the operational management of the IEPS. IEPS allows interoperability of different national implementations of priority/preference schemes, thereby providing end-to-end preferential treatment to authorized narrow-band voice and data calls.
+
+The scope of [ITU-T E.106] is framed in the context of the PSTN, ISDN or PLMN. The IEPS provides priority treatment for international telephony service for authorized users over connection-oriented telecommunications networks. Therefore, based on bilateral/multilateral agreement between countries/administrations, IEPS could be used in such a scenario for interconnection of ETS national implementations.
+
+### 9.2.4 ITU-T H.323 system control protocols
+
+This clause outlines protocols used in the ITU-T H.323 system in support of priority telecommunications.
+
+[ITU-T H.460.4] specifies the call priority designation and country/international network of call origination identification for ITU-T H.323 priority calls. The ITU-T H.460.4 call priority designation parameter supports both the priority call indicator and five priority levels.
+
+[ITU-T H.248.1] defines the protocols used between elements of a physically decomposed multimedia gateway, used in accordance with the architecture as specified in [ITU-T H.323]. For government authorized emergency services (e.g., ETS), [ITU-T H.248.1] defines the IEPS call indicator and priority indicator. The IEPS call indicator carries the priority indication between the controller and gateway functions. The priority indicator supports 16 priority levels that can carry the user priority level between the controller and gateway functions. The IEPS call indicator and priority indicator satisfy the ETS requirements of indicating an ETS context and carrying the priority level, respectively. For public safety services, [ITU-T H.248.1] defines the emergency indicator for carrying the priority indication between the controller and gateway functions.
+
+[ITU-T H.248.81] provides guidelines on the use of the IEPS call indicator and priority indicator in ITU-T H.248 profiles for ITU-T H.323 and NGN systems in support of priority services (e.g., ETS).
+
+### 9.2.5 Diameter
+
+The Diameter protocol [IETF RFC 3588] supports authentication, authorization, and accounting (AAA) for network functions and applications such as network access and IP mobility.
+
+The following attribute value pairs (AVPs) are intended to be used in the Diameter protocol in support of priority services (e.g., ETS):
+
+- MPS-Identifier.
+- Reservation-Priority.
+- Priority-Level (as part of the allocation retention priority (ARP) AVP).
+- Session-Priority.
+
+The MPS-Identifier AVP is defined by 3GPP in [b-3GPP TS 29.214]. The MPS-Identifier is used to mark a priority service (e.g., an ETS/MPS) request over the Rx interface. The MPS-Identifier AVP contains the national variant for the priority service name.
+
+The Reservation-Priority AVP is defined by the European Telecommunications Standards Institute (ETSI) in [ETSI TS 183 017]. [ITU-T Q.3321.1] and [ITU-T Q.3303.3] specify the use of the Reservation-Priority AVP over the resource and admission control function (RACF) Rs and Rw interfaces [ITU-T Y.2111], respectively, in support of priority services. Similarly, [b-3GPP TS 29.214] (Policy and charging control over Rx reference point) and [ITU-T Q.1741.6] specify the Reservation-Priority AVP over the policy and charging control (PCC) Rx interface in support of priority services (e.g., ETS). The Reservation-Priority AVP supports 16 priority levels
+
+that can be used to request priority treatment. Values between 0 and 15 are in increasing order of priority with "15" being the highest and "0" the lowest. The Reservation-Priority AVP includes the priority value of the user.
+
+The Priority-Level AVP (as part of the allocation retention priority (ARP) AVP) is defined by 3GPP in [b-3GPP TS 29.212] (Policy and charging control over Gx reference point) and [ITU-T Q.1741.6]. [ITU-T Q.1741.6] specifies the Priority-Level AVP over the policy and charging control (PCC) Gx interface in support of priority services (e.g., ETS). The Priority-Level AVP supports 15 priority levels that can be used to request priority treatment. Values between 1 and 15 are in decreasing order of priority with "1" being the highest and "15" the lowest. Priority values 1 to 8 are assigned for services that are authorized to receive prioritized treatment (e.g., ETS, MPS). Priority value "0" is spare and treated as a logical error if received. The Priority-Level AVP reflects the priority value of the user.
+
+The Session-Priority AVP is defined in [b-3GPP TS 29.229] (Cx and Dx interfaces based on the Diameter protocol; Protocol details) and [ITU-T Q.1741.6]. [b-3GPP TS 29.229] specifies the use of the Session-Priority AVP over the Cx and Dx interfaces in support of priority services (e.g., ETS). Similarly, [b-3GPP TS 29.329] (Sh interface based on the Diameter protocol; Protocol details) and [ITU-T Q.1741.6] specify the use of the Session-Priority AVP over the Sh interface in support of priority services. The Session-Priority AVP supports 5 priority levels that can be used to request priority treatment over the Cx, Dx, and Sh interfaces. Values between 0 and 4 are defined to be in decreasing order of priority with "0" being the highest and "4" the lowest.
+
+## **9.3 Transport stratum**
+
+### **9.3.1 General**
+
+The need for special arrangements (e.g., SLA) to handle ET in a properly-engineered and dimensioned NGN is based on an assumption that the network resources are inadequate for the amount of traffic being offered to the network, and that under such conditions emergency telecommunications traffic could be rejected or significantly delayed and/or disrupted beyond the point of being usable, or even be discarded. When the amount of traffic being received with a statistically-engineered or best-effort service model exceeds the capacity of a given receiving network element (e.g., an IP router) and the outgoing capacity available to the given element, the only recourse open to this network element is to discard the excess traffic. This means that emergency traffic would be discarded along with non-emergency traffic unless special preferential measures are enabled (e.g., as specified within an SLA). The TM Forum has provided guidance on the specification and management of SLAs [b-TM Forum GB917], and, in particular, has considered how such guidance could be applied to ETS.
+
+The technique of over-provisioning is sometimes advocated as a solution. However, over-provisioning may not be possible or practical in many cases, and more importantly, some kinds of emergencies may result from deliberate or accidental destruction or degradation of parts of the network, and thus eliminate any over-provisioned paths or elements that might normally have been available. Thus, the over-provisioning has negative impacts. If an NGN is to be capable of handling all kinds of emergencies under adverse circumstances, the availability of specific means to provide preferential treatment of emergency telecommunications traffic will be necessary.
+
+The following clauses outline a number of mechanisms used to obtain priority treatment at the transport level in the context of a packet-based NGN.
+
+### **9.3.2 Bandwidth control using RSVP**
+
+One possible feature of an IP-based network that is able to provide some (rough) equivalence to a circuit-based bandwidth allocation would be an IP-based mechanism for bandwidth allocation and reservation. This exists as a procedure defined by the IETF in its resource reservation protocol
+
+(RSVP) specified in [IETF RFC 2205] and its updates [b-IETF RFC 2750], [b-IETF RFC 3936], and [b-IETF RFC 4495].
+
+The resource control parameterization necessary for session initiation protocol (SIP) in the service stratum to be used in conjunction with RSVP (in the transport stratum) is specified in [IETF RFC 3312]. This permits RSVP signalling to be used before, during and/or interwoven with the SIP signalling procedures. Some examples of this are given in [IETF RFC 4542] Appendix A. However [IETF RFC 4542] uses the pre-emption technique.
+
+IETF is currently developing extensions to the RSVP that can be used to support an admission priority capability at the network layer to allow a higher probability of session establishment to specific sessions in times of network congestion. It specifies new RSVP extensions to increase the probability of call completion without pre-emption. Engineered capacity techniques in the form of bandwidth allocation models are used to satisfy the "admission priority" required by an RSVP capable emergency telecommunications network. In particular, these extensions specify two new RSVP policy elements allowing the admission priority to be conveyed inside RSVP signalling messages so that RSVP nodes are able to enforce selective bandwidth admission control decisions based on the call admission priority.
+
+### **9.3.3 Queuing control using differentiated services**
+
+[IETF RFC 4594] outlines a recommended mapping between service classes and differentiated services code points (DSCP). Figure 3 of [IETF RFC 4594] includes a mapping table which allocates the expedited forwarding class to telephony applications. This allows IP packets to contain a DSCP value allocated to the expedited forwarding class.
+
+Furthermore, [ITU-T Y.1541] also recommends that voice traffic be marked (labelled) in the IP packets with the DSCP corresponding to EF. Network elements (routers) in the transport stratum receiving packets marked EF will assure timely delivery of time-critical traffic relative to non-time-critical traffic using the expedited forwarding behaviour defined for the EF code point and specified in [IETF RFC 3246].
+
+However, the EF code is used for normal telephony traffic. Consequently, there may still be a need to somehow differentiate between emergency telephony traffic and non-emergency telephony traffic, see next clause.
+
+### **9.3.4 EF DSCP for capacity-admitted traffic**
+
+[IETF RFC 5865] defines a VOICE-ADMIT DSCP for a class of traffic that is subject to strict CAC and includes ETS traffic. This would permit real-time traffic conforming to the expedited forwarding (EF) per hop behaviour using a CAC procedure involving authentication, authorization, and capacity admission (see clauses 9.3.1 and 9.3.2 above) as opposed to a class of real-time traffic conforming to the expedited forwarding per hop behaviour that has not been subject to capacity admission.
+
+### **9.3.5 Explicit congestion notification (ECN)**
+
+[IETF RFC 3168] defines the dual layer architecture of ECN as one that operates at the network layer (i.e., IP) and the transport layer (e.g., TCP). Its objective is to provide a timely explicit signalled feedback to the source of downstream congestion, but with minimal to no loss of packets, and therefore with minimal disruption of flows. This signalled information is accomplished using intermediate nodes supporting active queue management (AQM), which mark packets with congestion notification and forward them downstream instead of dropping the packet. The end point of the flow then sends feedback indication (i.e., ECN) back to the source via an upper layer transport protocol. [IETF RFC 4340] extended the support of ECN to the data congestion control protocol (DCCP).
+
+In the case of both TCP and DCCP, ECN triggers inherent back-off algorithms that are transparent to applications. The general benefit of this feature is that applications become more net-friendly and reduce the offered load, thereby allowing more users/applications to use the network. In this application-transparency scenario, ECN does not specifically favor ETS users over the general public. Rather, ECN facilitates the continued use of network resources by both ETS and general public users.
+
+The IETF Network Working Group is currently studying how ECN can be used for RTP flows running over UDP/IP which use RTCP as a feedback mechanism. The solution consists of feedback of ECN congestion experienced markings to the sender using RTCP, verification of ECN functionality end-to-end, and how to initiate ECN usage. The current studies within IETF are designed to add ECN support for real-time applications (e.g., voice and video) using RTP/RTCP. In this case, notification of congestion is made available to applications, which may have a variety of reactions to this notification. It can be expected that the default reaction will follow that of TCP and DCCP, wherein the application reduces the offered load onto the network.
+
+## **9.4 NGN access technology support**
+
+### **9.4.1 General**
+
+There are multiple technology-dependent methods for NGN access. According to [ITU-T Y.2012], access network includes access-technology dependent functions, e.g., for W-CDMA technology and xDSL access. Depending on the technology used for accessing NGN services, the access network includes functions related to:
+
+- 1) cable access;
+- 2) xDSL access;
+- 3) wireless access (e.g., [b-IEEE 802.11]) and [b-IEEE 802.16] technologies, and 3G RAN access);
+- 4) optical access.
+
+To support emergency telecommunications, special arrangements are also needed in the NGN access segment. The need for special arrangements is based on the assumption that in the same way that the core network resources are limited, access resources are also limited. Therefore, depending on the amount of traffic being offered to the access network segment, emergency telecommunications traffic could be impacted (e.g., rejected or significantly delayed and/or disrupted beyond the point of being usable, or even be discarded).
+
+Therefore, if the NGN is to be capable of handling all kinds of emergencies under adverse circumstances, the availability of specific means to provide preferential treatment of emergency telecommunications traffic needs to be supported in the NGN access segment. This includes, but is not limited to, mechanisms and capabilities for:
+
+- recognizing emergency telecommunications traffic;
+- preferential/priority access to resources/facilities;
+- preferential/priority routing of emergency telecommunications traffic;
+- preferential/priority establishment of emergency telecommunications sessions/calls.
+
+In establishing priority treatment for emergency telecommunications, the following aspects are considered: classifying or labelling the traffic for priority treatment, signalling to set up the path for transporting this traffic and mechanisms including the policies to support the requested priority. Some aspects such as the selection of mechanisms, policies and associated implementations are not standardized and may be region specific.
+
+### 9.4.2 Wireless access
+
+Wireless access networks are required to support specific mechanisms and capabilities to provide preferential/priority treatment to authorized emergency telecommunications calls or sessions. Technology-dependent mechanisms and capabilities may be used to provide the preferential/priority treatment. This includes, but is not limited to, mechanisms and capabilities for:
+
+- Recognizing emergency telecommunications traffic: This includes identification and marking of authorized emergency telecommunications.
+- Preferential/priority access to resources/facilities: This facilitates delivering a request for emergency telecommunications to a NGN when available access resources are scarce.
+- Preferential/priority routing of emergency telecommunications traffic: This may include features such as queuing for available resources, exemption from certain restrictive network management functions and reservation of some routes/paths for emergency telecommunications.
+- Preferential/priority establishment of emergency telecommunications calls or sessions.
+
+#### 9.4.2.1 Universal mobile telecommunications system (UMTS) and long term evolution (LTE)
+
+Priority service and multimedia priority service for 3GPP systems is specified in [b-3GPP TS 22.153]. The 3GPP-specified priority service and multimedia priority service allow authorized users to obtain priority access to the next available radio (voice or data traffic) channels before other users during situations when congestion is blocking call attempts. Priority service supports priority call progression and call completion to support an "end-to-end" priority call from mobile-to-mobile networks, mobile-to-fixed networks, and fixed-to-mobile networks. Multimedia priority service supports priority progression of multimedia sessions and completion to support "end-to-end" priority multimedia sessions, including from mobile-to-mobile networks, mobile-to-fixed networks, and fixed-to-mobile networks.
+
+Based on [b-3GPP TS 22.153], 3GPP is developing a Stage 2 Technical Report for enhancements for multimedia priority service (MPS) [b-3GPP TR 23.854] to identify changes to existing Stage 2 3GPP specifications (e.g., [b-3GPP TS 23.401], [b-3GPP TS 23.203], [b-3GPP TS 23.328], and [b-3GPP TS 23.272]) to support MPS, including IP multimedia subsystem (IMS) and policy and charging control (PCC) aspects. This TR is intended to clarify the architectural requirements and call or session flows for MPS. Based on the 3GPP Stage 2 requirements, changes to the existing 3GPP Stage 3 specifications to support MPS for UMTS and LTE access technologies will be specified.
+
+#### 9.4.2.2 Evolution – Data optimized (EV-DO)
+
+Similar to 3GPP, 3GPP2 specified multimedia priority service (MMPS) for 3GPP2 systems. The 3GPP2 specification for MMPS is [b-3GPP2 S.R0117-0]. Several capabilities such as updating of bearer priority levels are included in 3GPP2 systems network interface standards, and these capabilities may be used for providing MMPS. Similarly, several capabilities such as queuing are included in the 3GPP2 systems air interface standards and these capabilities may be used for providing MMPS.
+
+#### 9.4.2.3 WiMAX network access
+
+[b-WFM Stage1-r1] defines the Stage 1 requirements for emergency telecommunications service (ETS) over WiMAX networks for Release 1.6, based on [b-IEEE 802.16] 2009 air interface. [b-WFM Stage1-r2] enhances the Release 1.6 WiMAX ETS Stage 1 requirements for Release 2.0 to support the [b-IEEE 802.16m] air interface.
+
+[b-WFM Stage2-a1] specifies for ETS the Stage 2 WiMAX network solution framework for Release 1.6 to support the Stage 1 requirements. The framework addresses network initiated priority indication and priority treatment for the authentication, authorization, and accounting (AAA) architecture. The ETS framework based on the policy and charging control (PCC) architecture and UE initiated priority mechanisms are being developed for Release 2.0.
+
+[b-WFM Stage3-a1] specifies the Stage 3 WiMAX network procedures and messages for Release 1.6 supporting priority indication and priority treatment, based on the Stage 2 solution framework. A priority indication field is added to the QoS Descriptor parameter of the WiMAX RADIUS and Diameter messages. The priority indication procedures for the network initiated AAA architecture, as well as the priority treatment mechanisms in the BS, ASN gateway, and connectivity service network (CSN) functional entities, are also described in this document. The key areas of ETS support in the WiMAX network are as follows:
+
+- 1) Upon initial network entry for a UE associated with an ETS enabled WiMAX subscription, priority indications associated with initial service flows for the UE are passed from the authentication, authorization, and accounting (AAA) server to the access service network (ASN) gateway to the base station (BS). The BS applies priority treatment on resource allocation and scheduling for the priority service flows.
+- 2) Upon ETS invocation from a UE, priority indications associated with service flows for the UE are passed from the application function (AF) to the AAA/policy function (PF) server to the ASN gateway to the BS. The BS applies priority treatment on resource allocation and scheduling for the priority service flows.
+- 3) Upon handover, priority indications associated with service flows for the UE are retained from the serving BS to the target BS for intra-ASN handover and from the serving ASN gateway to the target ASN gateway. The BSs apply priority treatment on resource allocation and scheduling on all priority service flows during handover preparation and action.
+- 4) Upon paging to a UE in the idle mode, priority indication associated with the service flow are passed from the ASN gateway with data path function to the anchor paging controller, and then to the BS. The BS applies priority treatment on resource allocation and scheduling for priority service flows in broadcasting paging messages. In response to priority paging, when the UE enters the network, the BS recognizes the incoming ETS call priority and gives priority treatment to the UE for idle mode exit as well as service flow addition/change for the ETS call to the terminating UE.
+
+The additional ETS Stage 3 procedures and messages are being developed for Release 2.0, which include priority indication and treatment for ranging, service flow creation, and universal services interface (USI).
+
+#### **9.4.3 Fixed access**
+
+Fixed access networks are required to support specific mechanisms and capabilities to provide preferential/priority treatment to authorized emergency telecommunications calls or sessions. Technology-specific mechanisms (e.g., [b-802.1p] with xDSL, IPCablecom, IPCablecom 2) mechanisms and capabilities may be used to provide the preferential/priority treatment. This includes, but is not limited to, mechanisms and capabilities for:
+
+- Recognizing emergency telecommunications traffic: This includes identification and marking of authorized emergency telecommunications.
+- Preferential/priority access to resources/facilities: This facilitates delivering a request for emergency telecommunications to a NGN when available access resources are scarce.
+
+- Preferential/priority routing of emergency telecommunications traffic: This may include features such as queuing for available resources, exemption from certain restrictive network management functions and reservation of some routes/paths for emergency telecommunications.
+- Preferential/priority establishment of emergency telecommunications calls or sessions.
+
+The technology-specific considerations are described in the following subclauses.
+
+#### **9.4.3.1 IPCablecom network access**
+
+[ITU-T J.260] defines the requirements for preferential telecommunications service over IPCablecom networks. [ITU-T J.261] defines the framework for developing the specifications in order to support these requirements over both IPCablecom and IPCablecom 2 networks. The framework addresses two key areas: priority and authentication. Other areas such as provisioning for restorability are identified for future revisions. The framework is defined to include both common aspects as well as differences resulting from the architectures used in IPCablecom and IPCablecom 2 networks (IMS-based). IPCablecom and IPCablecom 2 are packet networks that have the properties discussed in clause 6 such as sharing resources for data and control traffic. The framework in [ITU-T J.261] classifies the priority requirements in [ITU-T J.260] in terms of signalling, labelling and mechanisms.
+
+[ITU-T J.262] defines the specification to support the authentication requirements in IPCablecom 2 networks. Example flows are included in [ITU-T J.262] to show the message exchanges for different scenarios corresponding to PIN-based authentication, use of SIP Resource Priority header: user agent originating a VoIP call to PSTN user using a PIN, user agent originating a VoIP call to another VoIP user agent using a PIN-and subscription-based authentication.
+
+[ITU-T J.263] defines the specification to support the priority signalling for preferential treatment using [IETF RFC 4412] SIP Resource Priority header. Two options are included in the specification: (1) the UA initiates the request including the Resource-Priority header; (2) based on the information in the request, the Resource-Priority header with the appropriate priority level value is inserted by the P-CSC-FE. The namespace and priority level values to be used in different regions are included as annexes to [ITU-T J.263]. In some regions, it is required to support the values defined in [IETF RFC 4412]. [ITU-T J.263] also describes the relationship to service flows that are set up during provisioning of the embedded multi-terminal adapter (E-MTA) at the DOCSIS MAC layer to reflect the required QoS parameters for preferential telecommunications. There is no labelling mechanism identified for the data transfer because RTP does not include markings to indicate priority. Priority enabling mechanisms to reserve resources and perform admission control are supported by setting gates defined as part of dynamic quality of service (DQoS) in IPCablecom.
+
+#### **9.4.3.2 xDSL network access**
+
+The Ethernet-based DSL aggregation reference architecture is described in [BBF TR-101]. Policy control in the DSL access network is based on the specifications found in [BBF TR-058] and [BBF TR-059].
+
+The basic approach to providing ETS capabilities in a DSL access network is to use the existing QoS capabilities to provide priority to ETS calls or sessions. The policy server/policy decision point (PDP) is the only "ETS-aware" device in this approach, and it sets the appropriate priority to be applied to flows using existing QoS capabilities in the broadband network gateway (BNG).
+
+Due to the non-blocking nature of the network interface device (NID) and main distribution frame (MDF), no ETS features are required in these network elements. Bandwidth is provisioned and is fixed between the NID and the digital subscriber line access multiplexer (DSLAM), and the DSLAM is also engineered to be non-blocking. Thus, the approach chosen is to use the QoS
+
+capabilities of the BNG to control the flow of the data through the DSLAM to ensure that the traffic does not congest the DSLAM.
+
+The Ethernet aggregation function is engineered to transport all traffic between the BNG and the DSLAM and is, therefore, another non-blocking element.
+
+The customer premises equipment (CPE) access gateway may or may not be ETS aware. If it is ETS aware, then the access gateway may prioritize ETS traffic to ensure transmission into the DSL access network, and to ensure that the DSLAM does not become congested.
+
+The policy server/PDP is responsible for providing the appropriate policy for ETS traffic to the BNG. For ETS, the policy server/PDP implements admission control policies to give an ETS call or session a high likelihood of being successful. The policies affect establishing, maintaining, and terminating the ETS call or session through the DSL access network to the customer premises network. It is assumed that the policy server/PDP will receive the ETS call or session request from the NGN (e.g., proxy call session control functional entity (P-CSC-FE)). The policy server/PDP will recognize the request with the appropriate ETS information and instruct the BNG appropriately to provide priority treatment.
+
+The BNG is responsible for providing priority to ETS traffic. The BNG applies instructions from the policy server/PDP when reserving and establishing appropriate resources for handling an ETS call or session. It applies priority treatment, including marking bearer packets for priority treatment for transmission to the CPE access gateway and to the regional broadband network.
+
+#### **9.4.3.3 Fibre (FTTx) network access**
+
+The fibre access passive optical network (PON) reference architecture is described in [ITU-T G.983.1]. The reference architecture refers to an access node management system (ANMS) for control of the optical line termination (OLT) and optical network termination (ONT). The ANMS provides the policy decision point (PDP) functionality that is enforced by the policy enforcement points (PEPs) located in the OLT and ONT.
+
+There is today no direct policy control or policy enforcement within the fibre access network. However, to support ETS priority handling of call or session set-up in the fibre access network, the ANMS will be required to support dynamic policy control functions. The basic approach to providing ETS capabilities in a fibre access network is to use the existing QoS capabilities to provide priority to an ETS call or session. The ANMS (e.g., policy server) is the only "ETS-aware" device in this approach, and it sets the appropriate priority to be applied to flows using the existing QoS capabilities in the OLT and ONT. ETS policy is signalled over the Q3 interface (as specified in [ITU-T Q.812]) to the OLT and is reflected from the OLT to the ONT via the ONT management and control interface (OMCI).
+
+The ANMS is responsible for providing the appropriate policy for ETS traffic to the OLT. For ETS, the ANMS implements admission control policies to give an ETS call or session a high likelihood of being successful. The policies affect establishing, maintaining, and terminating the ETS call or session in the fibre access network. The ANMS makes the final policy decisions and provides sufficient information to make the OLT and ONT perform the resource control operation for ETS. It is assumed that the ANMS will receive the ETS call or session request from the NGN (e.g., proxy call session control functional entity (P-CSC-FE)). The ANMS will recognize the request with the appropriate ETS information and instruct the OLT appropriately to provide priority treatment.
+
+The OLT and ONT are engineered to transport all ETS traffic. The OLT is responsible for providing priority to ETS traffic. The OLT applies instructions from the ANMS when reserving and establishing appropriate resources for handling an ETS call or session. It applies priority treatment, including marking bearer packets for priority treatment for transmission.
+
+# 10 End-to-end support for emergency telecommunications
+
+Figure 2 shows an end-to-end call or session matrix for supporting various ETS call or session flows. It illustrates calls or sessions:
+
+- originating and terminating on IP (e.g., Cable and DSL), narrow-band wireline (e.g., POTS phone), and wireless (e.g., GSM and CDMA phone) access; and
+- traversing through IP and circuit-switched (TDM) core networks.
+
+Support of the end-to-end ETS requires the interworking of ETS specific information between the IP technology domain and other technology domains (e.g., wireless or wireline TDM domains). This includes the necessary interworking for the end-to-end ETS call or session that may cross different technology domains shown in Figure 2. For example, the ETS specific information (e.g., ETS call marking, priority level) needs to be signalled across the network-to-network interface (NNI) between interconnecting NGN providers.
+
+
+
+Figure 2: End-to-end call or session matrix diagram. The diagram shows a network architecture with three main sections: 'Originating access', 'Core networks', and 'Terminating access'. In the 'Originating access' section, there are three yellow circles labeled 'WS' (Wireless access), 'NW' (Narrowband wireline access), and 'IP' (IP access), each with associated device icons. These are connected to four blue ovals in the 'Core networks' section: 'Core1-TDM', 'Core2-TDM', 'Core1-IP', and 'Core2-IP'. The 'Terminating access' section also has 'WS', 'NW', and 'IP' circles with device icons, connected to the same four core network ovals. Brackets at the bottom label the sections as 'Originating access', 'Core networks', and 'Terminating access'.
+
+WS Wireless access
+NW Narrowband wireline access
+
+NOTE – A core network is the authenticating network, a transit network, or both.
+
+Y.2205(11)\_F02
+
+**Figure 2 – End-to-end call or session matrix**
+
+The call or session scenarios associated with Figure 2 can be found in [b-ATIS-1000010]. [b-ATIS-1000010] defines the procedures and capabilities required to support ETS within and between IP-based service provider networks. The following call or session scenarios are possible based on the matrix shown in Figure 2:
+
+- Originating access to core network 1
+ - Originating wireline access to IP core network
+ - Originating wireless access to IP core network
+ - Originating IP access to IP core network
+ - Originating IP access to TDM core network
+- Core 1 network to core 2 network
+ - TDM core network to IP core network
+ - IP core network to TDM core network
+ - IP core 1 network to IP core 2 network
+- Core 2 Network to terminating Access
+ - IP core network to wireline terminating access
+ - IP core network to wireless terminating access
+ - IP core network to IP terminating access
+ - TDM core network to IP terminating access
+
+Setting up the ETS call or session requires careful implementation of the necessary signalling protocols that convey the required information signifying the critical nature of ETS. In order to support end-to-end priority treatment, it is important to support the mapping of priority information to facilitate seamless protocol interworking between the different protocols used within a network (e.g., vertical protocol interworking between call or session control and bearer control) or between different network types (e.g., call or session control interworking between two networks) including PSTN. Similarly, it is critical to allow mapping of priority information to facilitate seamless interworking between the different transport types, i.e., media types. Without such an interworking/mapping, end-to-end priority treatment may not be achievable.
+
+ITU-T is currently preparing guidance for mapping required signalling protocol attributes (ETS priority information) to support the proper set-up and admission of ETS for various "horizontal" (e.g., ISUP, SIP, ITU-T H.225.0) and "vertical" (e.g., ITU-T H.248.0, Diameter).
+
+[ITU-T Q-Sup.57] provides signalling requirements to support preferential capabilities within IP networks for the ETS. An example call flow from [ITU-T Q-Sup.57] illustrating successful authentication and set-up of ETS call or session is provided in Appendix III.
+
+# **11 Mechanisms and capabilities supporting some aspects of early warning in NGN**
+
+## **11.1 General**
+
+Alert systems used for early warning may be classified by whether they employ a push or pull models.
+
+The push model relies on participants registering their contact information (e.g., an e-mail address) to a central service. When an event occurs, these registered participants are alerted to the event with potentially more pointers to additional information. A key architectural design in this model is that a central authority determines if information is to be disseminated, and what that information entails. The strength in this model is that it takes on the burden of being active in monitoring events, thus allowing users to continue in their normal responsibilities and remain passive concerning the monitoring of potential disasters or emergencies.
+
+The push model represents a "one" to "many" distribution mechanism, and is enabled at both the service and transport stratum (e.g., multicast).
+
+The pull model is the opposite of the push model in that the former relies on a query-response exchange of information. While both models rely on registrations by individual participants, the pull model places the responsibility of monitoring and obtaining information onto the individual users. The advantage of this system is that information is only provided on an as-needed or on-demand basis.
+
+In summary, alert systems use existing applications and underlying capabilities found in IP-based networks. The addition of pull or push helps make these systems more symbiotic to the needs and expectations of users. The application of each type of alert system can also be used in tandem: the push model can provide periodic automated monitoring and notification, and the pull model can be used to obtain on-demand specific information.
+
+For examples of push and pull, see Appendix II.
+
+## **11.2 Common alerting protocol (CAP)**
+
+This clause describes the common alerting protocol (CAP) specified in [ITU-T X.1303] that can be used to support early warning applications. CAP uses the extensible markup language (XML) and provides standard data interchange formats for structured information.
+
+[ITU-T X.1303] specifies a general format for exchanging all-hazard emergency alerts and public warnings over all kinds of networks. CAP allows a consistent warning message to be disseminated
+
+simultaneously over many different warning systems, thus increasing warning effectiveness while simplifying the warning task. CAP also facilitates the detection of emerging patterns in local warnings of various kinds, such as might indicate an undetected hazard or hostile act. CAP also provides a template for effective warning messages based on best practices identified in academic research and real-world experience.
+
+The CAP provides an open, non-proprietary message format for all types of alerts and notifications. It does not address any particular application or telecommunications method. The CAP format is compatible with emerging techniques, such as web services and the ITU-T fast web services, as well as existing formats including the specific area message encoding (SAME) used for the United States National Oceanic and Atmospheric Administration (NOAA) weather radio and the emergency alert system (EAS), while offering enhanced capabilities that include:
+
+- flexible geographic targeting using latitude/longitude shapes and other geospatial representations in three dimensions;
+- multilingual and multi-audience messaging;
+- phased and delayed effective times and expirations;
+- enhanced message update and cancellation features;
+- template support for framing complete and effective warning messages;
+- compatibility with digital encryption and signature capability; and
+- the facility to transmit digital images and audio.
+
+CAP provides reduction of costs and operational complexity by eliminating the need for multiple custom software interfaces to the many warning sources and dissemination systems involved in all-hazard warning. The CAP message format can be converted to and from the "native" formats of all kinds of sensor and alerting technologies, forming a basis for a technology-independent national and international "warning internet".
+
+The CAP specified in [ITU-T X.1303] is technically equivalent and compatible with the OASIS common alerting protocol, V1.1 standard. OASIS also specified CAP V1.2 providing updates to CAP V1.1.
+
+[ITU-T X.1303] provides an equivalent ASN.1 specification that permits a compact binary encoding and the use of ASN.1 as well as XML schema definition (XSD) tools for the generation and processing of CAP messages. [ITU-T X.1303] enables existing systems, such as ITU-T H.323 systems, to more readily encode, transport and decode CAP messages.
+
+## **11.3 Procedures for the registration of arcs under the alerting object identifier arc**
+
+[ITU-T X.674], "Procedures for the registration of arcs under the Alerting object identifier arc", provides for the registration of object identifier (OID) arcs to identify different kinds of alerts and alerting agencies. Specifically, it specifies the procedures for the registration of arcs to identify (all kinds of) alerts and alerting agencies under the Alerting object identifier arc {joint-iso-itu-t(2) alerting(49)} according to [ITU-T X.660].
+
+[ITU-T X.674] facilitates the allocation and use of OIDs to identify alerting agencies (e.g., alerting agencies designated by World Meteorological Organization (WMO) Member States).
+
+NOTE – The WMO maintains a registry of Alerting Authorities. This can be found at: .
+
+# **12 Service restoration priority**
+
+In the event of a network failure or outage, critical services (e.g., emergency services) can be interrupted and may need a higher probability of successful restoration over other services. [ITU-T Y.2172] specifies three levels for restoration priority for services in NGN. It allows for such priority classifications to be used in signalling messages such that the service in question can get call or session set-up with the desired restoration priority, thus allowing critical services to have a higher probability of successful restoration over other services.
+
+# **13 Protection switching and restoration**
+
+## **13.1 General considerations**
+
+A number of general concepts common to many transport technologies are described in [ITU-T G.808.1]. Several important issues to be considered when providing protection for emergency telecommunications traffic are identified in [ITU-T G.808.1].
+
+### **13.1.1 Individual protection**
+
+The individual protection concept applies to those situations where it is useful to protect only a part of the traffic signals which need high reliability.
+
+### **13.1.2 Group protection**
+
+This allows protection switching through the treatment of a logical bundle of transport entities as a single entity after the commencement of protection actions.
+
+### **13.1.3 Architectural types**
+
+The following architecture types are identified in [ITU-T G.808.1] and are summarized below.
+
+#### **13.1.3.1 1+1 protection architecture**
+
+In the 1+1 architecture type, a protection transport entity is dedicated as a backup facility to the working transport entity.
+
+#### **13.1.3.2 1:n protection architecture**
+
+In the 1:n architecture type, a dedicated protection transport entity is a shared backup facility for n working transport entities.
+
+#### **13.1.3.3 m:n protection architecture**
+
+In the m:n architecture type, m dedicated protection transport entities share backup facilities for n working transport entities, where $m \leq n$ typically.
+
+#### **13.1.4 Switching types**
+
+The protection switching types can be a unidirectional switching type or a bidirectional switching type.
+
+It should be noted that all switching types, except 1+1 unidirectional switching, require a communications channel between the two ends of the protected domain; this is called the automatic protection switching (APS) channel.
+
+A list of advantages/disadvantages of applying switching types to all the cases above is given in [ITU-T G.808.1].
+
+In the context of an IP-based emergency telecommunications, unidirectional switching may be adequate since, in general, the paths in each direction are not directly associated due to the nature of unidirectional nature of paths/routing through IP-based networks.
+
+### 13.1.5 Operation types
+
+The protection operation types can be a non-revertive operation type or a revertive operation type.
+
+In revertive operation, the traffic signal (service) always returns to (or remains on) the working transport entity when it has recovered from the defect.
+
+In non-revertive operation, the traffic signal (service) does not return to the original working transport entity.
+
+It is noted in [ITU-T G.873.1] 1+1 protection is often provisioned as non-revertive, as the protection is fully dedicated in any case, and this avoids a second "glitch" to the traffic. There may, however, be reasons to provision this to be revertive (e.g., so that the traffic uses the "short" direction around a ring except during failure conditions. Certain operator policies also dictate revertive operation even for 1+1).
+
+## 13.2 SDH protection architectures
+
+[ITU-T G.841] provides the necessary equipment-level specifications to implement different choices of protection architectures for synchronous digital hierarchy (SDH) networks.
+
+Protected entities may range from a single SDH multiplex section (e.g., linear multiplex section protection), to a portion of an SDH end-to-end path (e.g., subnetwork connection protection), or to an entire SDH end-to-end path. Physical implementations of these protection architectures may include rings or linear chains of nodes. Each protection classification includes guidelines on network objectives, architecture, application functionality, switching criteria, protocols, and algorithms.
+
+Additionally, [ITU-T G.842] provides specifications for the interworking of network protection architectures. Specifically covered are single and dual node interconnection between MS-shared protection rings and subnetwork connection protection (SNCP) rings of the same or different types.
+
+## 13.3 Optical transport network (OTN)
+
+[ITU-T G.873.1] defines the automatic protection switching (APS) protocol and protection switching operation for the linear protection schemes for the optical transport network at the optical channel data unit (ODUk) level.
+
+The protection schemes considered in [ITU-T G.873.1] are:
+
+- ODUk subnetwork connection protection with inherent monitoring (1+1, 1:n);
+- ODUk subnetwork connection protection with non-intrusive monitoring (1+1);
+- ODUk subnetwork connection protection with sublayer monitoring (1+1, 1:n).
+
+For a given direction of transmission, the "head end" of the protected signal is capable of performing a bridge function, which will place a copy of a normal traffic signal onto a protection entity when required. The "tail end" will perform a selector function, where it is capable of selecting a normal traffic signal either from its usual working entity, or from a protection entity. In the case of bidirectional transmission, where both directions of transmission are protected, both ends of the protected signal will normally provide both bridge and selector functions.
+
+## 13.4 Ethernet linear protection switching
+
+[ITU-T G.8031] describes the specifics of protection switching for Ethernet VLAN signals. Included are details pertaining to Ethernet layer network (ETH) protection characteristics, architectures and the APS protocol.
+
+Linear 1+1 and 1:1 protection switching architectures with unidirectional and bidirectional switching are defined in [ITU-T G.8031].
+
+In the linear 1+1 protection-switching architecture, a protection transport entity is dedicated to each working transport entity. The normal traffic is copied and fed to both working and protection transport entities with a permanent bridge at the source of the protected domain. The traffic on working and protection transport entities is transmitted simultaneously to the sink of the protected domain, where a selection between the working and protection transport entities is made based on some predetermined criteria, such as server defect indication.
+
+Although selection is made only at the sink of the protected domain in linear 1+1 protection switching architecture, bidirectional 1+1 protection switching needs APS coordination protocol so that selectors for both direction selects the same entity. On the other hand, unidirectional 1+1 protection switching does not need APS coordination protocol.
+
+In the linear 1:1 protection switching architecture, the protection transport entity is dedicated to the working transport entity. However, normal traffic is transported either on the working transport entity or on the protection transport entity using a selector bridge at the source of the protected domain. The selector at the sink of the protected domain selects the entity which carries the normal traffic. Since source and sink need to be coordinated to ensure that the selector bridge at the source and the selector at the sink select the same entity, APS coordination protocol is necessary.
+
+## **13.5 Ethernet ring protection switching**
+
+[ITU-T G.8032] defines the automatic protection switching (APS) protocol and protection switching mechanisms for ETH layer Ethernet ring topologies. Included are details pertaining to Ethernet ring protection characteristics, architectures and the ring APS protocol.
+
+The protection protocol defined in [ITU-T G.8032] enables protected point-to-point, point-to-multipoint and multipoint-to-multipoint connectivity within the ring or interconnected rings, called "multi-ring/ladder network" topology.
+
+## **13.6 Linear protection switching for transport MPLS (T-MPLS)**
+
+[ITU-T G.8131] provides requirements and mechanisms for end-to-end trail and subnetwork connection (SNC) protection switching for transport MPLS (T-MPLS) networks. It describes the trail protection and SNC protection architectures types, the uni- and bidirectional switching types and the revertive and non-revertive operation types. It defines the automatic protection switching (APS) protocol used to align both ends of the protected domain.
+
+[ITU-T G.8131] specifies 1+1 architecture and 1:1 architecture. The 1+1 architecture operates with unidirectional switching. The 1:1 architecture operates with bidirectional switching.
+
+## **13.7 ATM protection switching**
+
+[ITU-T I.630] provides architectures and mechanisms for protection switching at the ATM layer. The architecture includes the extent of the protected domain and arrangement of protected domain. The resource for protection entities is pre-allocated. The mechanism includes a protection switching trigger, hold-off mechanisms and protection switching control protocol.
+
+[ITU-T I.630] describes individual VP/VC protection and group protection. The individual VP/VC protection is a technique where a single network or subnetwork connection is used for working entity and protection entity. The group protection is a technique where a logical bundle of one or more network or subnetwork connections is used for the working entity and protection entity.
+
+Currently, [ITU-T I.630] describes 1+1 and 1:1 bidirectional protection switching as well as 1+1 unidirectional protection switching.
+
+## 13.8 Protection switching for MPLS networks
+
+[ITU-T Y.1720] provides requirements and mechanisms for 1+1, 1:1, shared mesh, and packet 1+1 protection switching functionality for the user-plane in MPLS layer networks. The mechanism defined herein is designed to support end-to-end point-to-point LSPs.
+
+[ITU-T Y.1720] is developed to specify protection switching techniques. [ITU-T Y.1720] explains the difference between protection switching and re-routing as follows:
+
+Protection switching: This implies that both routing and resources are pre-calculated and allocated to a dedicated protection LSP prior to failure. Protection switching, therefore, offers a strong assurance of being able to re-obtain the required network resources post failure.
+
+Re-routing: This implies that a dedicated protection LSP is not defined, and so neither routing nor resources are pre-calculated or allocated prior to failure. Re-routing is commonly used to refer to cases where there are routing and signalling functions in operation, and that when a "re-connection request" has to be instigated on failure (either by the network, or by the customer), that this "reconnect request" has to contend with other similar traffic types for obtaining the required resource. Re-routing, therefore, offers no assurance of being able to re-obtain the required network resources post-failure and is generally slower than protection switching.
+
+Protection switching is necessary for fast recovery from failure, and thereby enhances the reliability and availability performance of MPLS networks.
+
+For protection switching, the following features are required:
+
+- 1) Protection switching should be applied to an entire LSP.
+- 2) Prioritized protection between signal fail and operator switch requests.
+- 3) The possibility to achieve protection at the MPLS layer as fast as possible (subject to the temporal resolution of the defect detection mechanism) should be provided.
+- 4) Protection ratio of 100%, i.e., 100% of impaired working traffic is protected for a failure on a single working LSP.
+- 5) An extra traffic capability should be supported, when possible.
+
+# **Appendix I**
+
+## **Emergency telecommunications categories**
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### **I.1 Individual-to-authority emergency telecommunications**
+
+An individual-to-authority emergency telecommunication is initiated from an individual using ordinary national emergency telecommunication capabilities to seek emergency assistance during an individual (personal) emergency, or even during a confined emergency situation. For example, an individual-to-authority call may involve a short dialled number (e.g., 112, 911, etc.) that provides an individual user a connection to an emergency-answering centre. The centre can dispatch the proper responders (e.g., police, firemen, ambulance) on behalf of the calling party. There may be additional information automatically signalled to the call centre such as caller location. Such information can facilitate an even more prompt reaction since sometimes callers cannot or do not have the time or ability to provide this information themselves. This type of communication is usually a one-to-one connection where the initiator interacts primarily with the destination agency. The vast majority of such telecommunications will involve small-scale emergencies (e.g., an individual house on fire) arising from mostly uncorrelated events although large-scale events (e.g., an earthquake) can result in many simultaneous correlated connections. (The term individual is meant broadly and should cover every person who needs emergency assistance (covering persons such as citizens, visitors or other inhabitants of a particular place.)) The participants in emergency telecommunications can communicate with each other using multiple types of media including voice, video, real-time text and instant messaging.
+
+### **I.2 Individual-to-individual emergency telecommunications**
+
+The individual-to-individual emergency telecommunications category is initiated from a person or device in the general public to an organization. For example, during and immediately after emergency situations, the public urge to communicate with each other is strong. Consequently, there is a higher demand for individual-to-individual telecommunications while at the same time telecommunication resources may be reduced, due to damage stemming from emergency events. Considering all these factors, telecommunication networks can congest.
+
+### **I.3 Authority-to-authority emergency telecommunications**
+
+The authority-to-authority emergency telecommunication typically involves an authorized emergency telecommunication user (or his/her organization) initiating action with another authorized user to:
+
+- 1) facilitate emergency recovery operations (e.g., by creating emergency control centres and associated administrative controls for resource assistance from government or other organizations);
+- 2) restore an essential community infrastructure (e.g., restoring essential water services, electricity, etc.); and
+- 3) initiate measures to enable long-term full recovery (e.g., rebuilding of roads, bridges, buildings, etc.).
+
+Historically, authority-to-authority (sometimes referred as public safety telecommunications) emergency telecommunications using public networks simultaneously occur when telecommunications resources are congested due to increased individual-to-individual telecommunications.
+
+Given the immense potential of authority-to-authority emergency telecommunications to facilitate restoring a state of normality and to avoid further risk to people or property, this emergency telecommunication category may be given priority status over other emergency telecommunication categories during times of declared emergencies or the escalations of these.
+
+### **I.4 Authority-to-individual emergency telecommunications**
+
+Finally, authority-to-individual emergency telecommunications (sometimes categorized as early warning systems) typically involve information intended for the public which comes from an authorized source. The content may include information intended for a disaster-affected community, such as safety, instructions, guidelines, advice etc. Usually, a particular telecommunication is initiated from one authorized user with many individuals as recipients.
+
+**Any-to-any:** An example of an ETS from any location/device, contacting any other user (ETS or general public) through some measure of preferential support by the communication infrastructure. GETS in the PSTN is a good example, where the preferential service is not ubiquitous and is not constrained to a selective set of end-devices or destinations.
+
+**One-to-one:** Within the context of emergency telecommunications, this one-to-one is considered a subset of the any-to-any case. In this case, the participants are constrained to any two ETS users.
+
+**Many-to-one:** One manifestation of this model is client-server architecture of the web, where any user accesses a single well-known location for information. In the PSTN, this model is realized via 911, 112, etc., systems, where sessions within a region are forwarded to a single public safety answering point (PSAP).
+
+**One-to-many:** In this model, information is sent from one source to the set of receivers (end users) choosing to participate in the dissemination of data. In the case of broadcast media, television and radio are excellent examples since receivers only obtain information from the channel they have selected. In the data communication model, one distinguishes one-to-many from broadcast because the latter infers that all nodes receive the message, whether they choose to or not, whereas the former implies direct membership of a group.
+
+# Appendix II
+
+## Example use cases for early warning alert systems
+
+(This appendix does not form an integral part of this Recommendation.)
+
+## II.1 Push model
+
+Both the private and public or government sectors offer alert systems based on the push model. However, this Recommendation only discusses an example from the public sector. An example of the push model from the public or government sector is the emergency information centre from the Washington D.C. () local government website. Users register their contact information in the form of an e-mail address, pager, or mobile phone number (either text messaging, or automated voice messaging). The automated voice messaging is equivalent to inverse-911 and all citizens of D.C., with the corresponding landline exchange, are automatically registered with this service. The alert service, as it pertains to e-mail and pagers, is not restricted to just Washington D.C. residents.
+
+## II.2 Pull model
+
+The best example of the pull model operating over the Internet is the I-AM-Alive project from Japan ([http://www.isoc.org/inet2000/cdproceedings/8I/8I\\_3.htm](http://www.isoc.org/inet2000/cdproceedings/8I/8I_3.htm), ). I-AM-Alive effort sprung from the Kobe earthquake in 1995 in order to allow people to determine the status and possible location of loved ones that were affected by the earthquake. It acts as an information collection centre for first responders to deposit information they have discovered. Conversely, it is also a distribution centre where friends and relatives can determine if people they know have been hurt by a disaster.
+
+The I-AM-Alive system uses a combination of input from fax, phone, and the web to store information placed by individuals and or first responders. Subsequent distribution of information is primarily in the form of web pages, though some information can be obtained from well-known phone numbers associated with the system.
+
+
+
+- 1) The call or session is routed to an ETS application server (AS) where user authentication processing is initiated.
+- 2) The ETS AS sends an INVITE message to the selected media server (MS), with an SDP offer associated with the caller. The INVITE message contains the URL of a VoiceXML script, stored at the ETS AS. The script describes how the MS should interact with the caller (what announcement to play, how to collect digits, how many digits to collect, inter-digit timers, etc.).
+- 3) Upon receipt of the INVITE message, the MS:
+ - May send a 100 Trying to the ETS AS;
+ - Retrieves the VoiceXML script directly from the ETS AS using HTTP and the URL in the INVITE message (MS sends a HTTP GET to the ETS AS and VoiceXML script is returned from the ETS AS in an HTTP 200 OK);
+ - Validates the script;
+ - Formulates and sends a 200 OK message containing its own SDP to the ETS AS.
+- 4) The ETS AS sends a 200 OK towards the calling party (NGN terminal), including in it the session information it received from the MS.
+- 5) At this point, the media connection is available between the MS and the calling party.
+- 6) Upon receipt of the ACK and VXML script in the HTTP 200 OK, the MS executes the VoiceXML script. It plays a tone and collects digits (PIN) entered by the calling party.
+- 7) The MS then sends the collected digits directly to the ETS AS using an HTTP POST message.
+- 8) Upon receipt of the collected digits, the ETS AS verifies whether the received digits (PIN) are valid.
+ - If the digits received are invalid (number of digits received or the wrong number), the ETS AS determines that further interaction with the caller is required. The ETS AS returns an HTTP 200 OK message to the MS with a new VoiceXML script. The ETS AS will instruct for final handling treatment.
+ - If the received digits are valid, the ETS AS will instruct the MS to play the announcement to collect the digits (destination number).
+- 9) The ETS AS determines that the calling party entered destination digits are valid.
+- 10) The ETS AS releases the MS from the call or session with a SIP BYE, and sends a reINVITE toward the calling party, with a SDP to place the media on hold.
+- 11) The ETS AS sends an INVITE toward the destination party. Upon receiving 200 OK (answer), the ETS AS sends a reINVITE with the SDP associated with the destination toward the calling party.
+- 12) The media path is established between the calling party and destination number with the authentication ETS AS in the call control path.
+
+# Bibliography
+
+- [b-ITU-T Q-Sup.62] ITU-T Q-series Recommendations – Supplement 62 (2011), *Overview of the work of standards development organizations and other organizations on emergency telecommunications service.*
+- [b-UN Global Survey] United Nations/International Strategy for Disaster Reduction (2006), *Final Report on a "Global Survey of Early Warning Systems"*.
+<>
+- [b-ATIS 1000010] ATIS-1000010.2006, *Support of Emergency Telecommunications Service (ETS) in IP Networks.*
+- [b-IEEE 802.11] IEEE Std 802.11-2007, *IEEE Standard for Information technology – Telecommunications and information exchange between system – Local and metropolitan area networks – Specific requirements, Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications.*
+- [b-IEEE 802.16] IEEE Std 802.16-2009, *IEEE Standard for Local and metropolitan area networks, Part 16: Air Interface for Broadband Wireless Access Systems.*
+- [b-IEEE 802.16m] IEEE Std 802.16m-2011, *IEEE Standard for Local and metropolitan area networks, Part 16: Air Interface for Broadband Wireless Access Systems, Amendment 3: Advanced Air Interface.*
+- [b-IEEE 802.1p] IEEE Std 802.1D-2004, *IEEE Standard for Local and metropolitan area networks; Media Access Control (MAC) Bridges.*
+- [b-3GPP TR 23.854] 3GPP TR 23.854 (in force), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Enhancements for Multimedia Priority Service (Release 10).*
+- [b-3GPP TS 22.153] 3GPP TS 22.153 (06/2008), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Multimedia priority service (Release 8).*
+- [b-3GPP TS 23.203] 3GPP TS 23.203 (in force), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Policy and Charging Control Architecture (Release 10).*
+- [b-3GPP TS 23.272] 3GPP TS 23.272 (in force), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; Circuit Switched (CS) Fallback in Evolved Packet System (EPS); Stage 2 (Release 10).*
+- [b-3GPP TS 23.328] 3GPP TS 23.228 (in force), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; IP Multimedia Subsystem (IMS); Stage 2 (Release 10).*
+- [b-3GPP TS 23.401] 3GPP TS 23.401 (in force), *3rd Generation Partnership Project; Technical Specification Group Services and System Aspects; General Packet Radio Service (GPRS) Enhancements for Evolved Universal Terrestrial Radio Access Network (E-UTRAN) Access (Release 10).*
+- [b-3GPP TS 29.212] 3GPP TS 29.212, version 9 6.1 (2011-04), *Universal Mobile Telecommunications System (UMTS); LTE; Policy and Charging Control over Gx reference point (Release 9).*
+
+| | |
+|---------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [b-3GPP TS 29.214] | 3GPP TS 29.214 (in force), 3rd Generation Partnership Project; Technical Specification Group Core Network and Terminals; Policy and Charging Control over Rx reference point (Release 10) . |
+| [b-3GPP TS 29.229] | 3GPP TS 29.229, version 9.3.0 (2010-10), Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); LTE; Cx and Dx interfaces based on the Diameter protocol; Protocol details (Release 9) . |
+| [b-3GPP TS 29.329] | 3GPP TS 29.329 v9.4.0 (2011-01), Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); LTE; Sh interface based on the Diameter protocol; Protocol details (Release 9) . |
+| [b-3GPP2 S.R0117-0] | 3GPP2 S.R0117-0-v1.0 (06/2006), 3rd Generation Partnership Project 2; Multimedia Priority Service (MMPS) for MMD-based Networks – Stage 1 Requirements . |
+| [b-IETF RFC 2750] | IETF RFC 2750 (2000), RSVP Extensions for Policy Control . |
+| [b-IETF RFC 3265] | IETF RFC 3265 (2002), Session Initiation Protocol (SIP) – Specific Event Notification . |
+| [b-IETF RFC 3853] | IETF RFC 3853 (2004), S/MIME Advanced Encryption Standard (AES) Requirement for the Session Initiation Protocol (SIP) . |
+| [b-IETF RFC 3936] | IETF RFC 3936 (2004), Procedures for Modifying the Resource reSerVation Protocol (RSVP) . |
+| [b-IETF RFC 4032] | IETF RFC 4032 (2005), Update to the Session Initiation Protocol (SIP) Preconditions Framework . |
+| [b-IETF RFC 4190] | IETF RFC 4190 (2005), Framework for Supporting Emergency Telecommunications Service (ETS) in IP Telephony . |
+| [b-IETF RFC 4320] | IETF RFC 4320 (2006), Actions Addressing Identified Issues with the Session Initiation Protocol's (SIP) Non-INVITE Transaction . |
+| [b-IETF RFC 4495] | IETF RFC 4495 (2006), A Resource Reservation Protocol (RSVP) Extension for the Reduction of Bandwidth of a Reservation Flow . |
+| [b-IETF RFC 4916] | IETF RFC 4916 (2007), Connected Identity in Session Initiation Protocol (SIP) . |
+| [b-IETF RFC 5027] | IETF RFC 5027 (2007), Security Preconditions for Session Description Protocol (SDP) Media Streams . |
+| [b-TM Forum GB917] | TM Forum GB917 (in force), SLA Management Handbook, Release 3.0 . |
+| [b-WFM Stage 1-r1] | WiMAX Forum – WFM-T31-122-R016v01 (2009), Service Provider Working Group (SPWG) ETS Phase 1 Requirements for Release 1.6 . |
+| [b-WFM Stage 1-r2] | WiMAX Forum – WFM-T31-122-R020v01 (2009), SPWG ETS Requirements, Release 2.0 . |
+| [b-WFM Stage 2-a1] | WiMAX Forum – WFM-T32-001-R016v01 (2010), Network Architecture – Architecture Tenets, Reference Model and Reference Points, Base Specification, Release 1.6, ) ETS Stage 2 Specification (Section 7.14) . |
+
+[b-WFM Stage 3-a1]
+
+WiMAX Forum – WFM-T33-001-R016v01 (2010), *Network Architecture – Detailed Protocols and Procedures, Base Specification, Release 1.6, ETS Stage 3 Specification (Section 4.19)*.
+
+
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/12c19090355e19922e23044633b9d1ea_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/12c19090355e19922e23044633b9d1ea_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..30631aec14678f67ecaf2bf074cea2f50b2e130e
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/12c19090355e19922e23044633b9d1ea_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ae3b586d76e35910e5491685965621f16756968362c918672bd7776642e4313c
+size 70223
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/1ab49904e6a60be337d5b75cb7cc8ab7_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/1ab49904e6a60be337d5b75cb7cc8ab7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5043b0c225f7dc2a8dfef838d6a9915361a8325f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/1ab49904e6a60be337d5b75cb7cc8ab7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7726d9f00c22304d3e5df30cb86b2abf34c99d1c662a14dd7929f3bdc35e653a
+size 64544
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/5ee1bbbf85b473f78af9ec8368a4159a_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/5ee1bbbf85b473f78af9ec8368a4159a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1e23062964a82d1fd920ed7ba46e58c70e26f308
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/5ee1bbbf85b473f78af9ec8368a4159a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:001cacf6a42ef23cb718ff75ccd969856918e10c510f7f0879396aa0a399aed7
+size 98850
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/6f659142d4789aa889184459f884787e_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/6f659142d4789aa889184459f884787e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..76bd8d558548a922ac63b6bcd37bd3a62777b374
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/6f659142d4789aa889184459f884787e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4c898b66432577a453249155d7b5653c54803b5b9005106b1f19152f2bd536ca
+size 43644
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c21c2350042e9c41b259116235392e38b293f038
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3bd40d6ee3880330c8240765ade87520f2140f912cd087a405ff8164fecbc5c4
+size 69451
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..30b2d5bf69a40d179b756dc34762704609983a59
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:68fd64463ab132373e6e530e3368f2b94a98f276040dda5baea1004d83e46f8d
+size 90163
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7fe5741e83bc9702d1b1d7585ddf66bd_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7fe5741e83bc9702d1b1d7585ddf66bd_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dccf57a9e3a57f88393a72156b770c5457d8a2a2
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/7fe5741e83bc9702d1b1d7585ddf66bd_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:378deeaf7848ba599540036f00f13030f5623e9ec0d13e199694cfd7de22e3eb
+size 85731
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8269648391c59363ea61243864a2adf7_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8269648391c59363ea61243864a2adf7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..87a7c8dab3471d13640ca972a8f21a324eba794d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8269648391c59363ea61243864a2adf7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d0cba2b26aaaa9db9869c7922600be810277d12f339d550873f993abdbd6580b
+size 55820
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8e80de0cac529b2c3775d677c5203133_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8e80de0cac529b2c3775d677c5203133_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4c95672e1a303eaa4647565b4fde550d0900b6ba
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/8e80de0cac529b2c3775d677c5203133_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4bf7d70142dcc2259f666dc7996b1ea04dc91084d3ace29d2601636c342a19f0
+size 89544
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9662dab9f1313342209faf613e68f54294d2cb01
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fc9d6a0a5699f278189ac19885825f5a118d3c8bd06eae9c8706ae62e764f773
+size 48917
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..36cf51f8ba07e44aa7a4b009f3ba08eb2b570b1c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:11780faeee75ba39ab4ed9de67a9e67abec0d9ba3068ebec661dea70c16e29d3
+size 4338
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c1278da91cbcabe32628e589ebc47418_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c1278da91cbcabe32628e589ebc47418_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2d1a60b39769b2c58e7d7169e1892ff64dcde501
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c1278da91cbcabe32628e589ebc47418_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b060871a95579776613de6f56dfca9b1d09f6774b19af19fd00c14b6384f7feb
+size 63865
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2a0bf1b6dce574d9423dd72cad87aa1b57b006c6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5c6a7dedae9e7d27e03431381dff336ea8259a4c73d9aacbe6bf8a800331fcfc
+size 71083
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1e8d6ad5b0ba88c266d16c4dbc279901a8d0a9d4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:485476a63c4dabbbca4de401e9c7d7f81fa2b215c471ee869ba52b49a033db7f
+size 69562
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0d7805bfe166cb816408449874674baa30ccb2d0
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e636d7ccca0ad14c6b95201404324823_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f6fc8949454819596f9c8d0340268e3eab56c59fcaaaea639fc7c8b9e2e0879c
+size 56631
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d38f74cab70e8cab150715d979a3f6e813e00d03
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8700a758efcd7912307faadc4aa1d0f2f1771a9155e569c28ded781453fb804d
+size 71610
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f1091147d93cee4dfa88498610e395a7_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f1091147d93cee4dfa88498610e395a7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dfbf2bae4a2f1dc43f20ac4992e4e6df0a388b4b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f1091147d93cee4dfa88498610e395a7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:be22bf27563e5ece4c245f2d571a1ab26176cc0f7a0b762f2a9857da203a6178
+size 71107
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5a5f52bc25d95a7f616290c99e88ae6_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5a5f52bc25d95a7f616290c99e88ae6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..faca9032316b6fe28741f3ede644dd4680261d1d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5a5f52bc25d95a7f616290c99e88ae6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:39f247b6d8cd95869bac857427b488e56080fe3ac60344940f5bc1e265925587
+size 81423
diff --git a/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5deee2f3301ee351c4008283ffafbb3_img.jpg b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5deee2f3301ee351c4008283ffafbb3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a3ba888185658af2c5e3f24ed2a451ba6e913f30
--- /dev/null
+++ b/marked/Y/T-REC-Y.2214-200905-I_PDF-E/f5deee2f3301ee351c4008283ffafbb3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aa929eff5cfc417862b423249ee73af01a4ba0431588349175e9aff6e46ba30e
+size 74237
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d5b8d45af1022ba37933eef0d3d033f233a5f30f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ffe6d185ffaa0e8fa4086c3bd1ceadd15f64191fa85e8abe3cf03a988c6ab622
+size 168265
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bb8075fa3d0cc32bd3eb53a57fc1ce102a6aa24c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:20959f5fb10f5d02626851653e23c0b819a9c5b780891bea575eaa55d446f28a
+size 81267
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0ccf9cbe20a67a7ead62944c7477b9f66669930f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:105d0bcaadc1bcdeed00c9adf9789630a3027b608855df79c53ddef897dcfe7d
+size 66898
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c23fd5fc9a8cacb0972a21a9931658c54a20dfdb
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a402b0e8ed6c690b290e2e16b41bab47e5582ecab4d66efbb293734c72eaf656
+size 61912
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3472689858b068ef469213682965325_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3472689858b068ef469213682965325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..32c4670ec23afd016da53e62681d6cb93f93e6c3
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3472689858b068ef469213682965325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1f4e35c9117b6bd4ec17442d88c538046a150c3b2269945c5df2875f42dc8096
+size 132655
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b362cc50f4bcac6db817cf2ac75ad68354a68626
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5facb3dff15d6ce04dd6e4620e1ff409d9d59756bf593d0c2cdcacfcad874ae2
+size 4352
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..eba33ec41f3d2a36c22959b1d575b5bed06ada7c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/ab846b81e78dbc8da2a6f9511e2f248a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e193bcb83075f882ca7cc745e271d32c14717a263b133962b3956c9c02743607
+size 98834
diff --git a/marked/Y/T-REC-Y.2221-201001-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..533b8ea1b48538b36131547a07ee9fed6895eba9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2221-201001-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8843773dddf912aecdf57e9e4c84fa8b8b8bdb035f936ec62bf65cf7cfc6a28c
+size 73136
diff --git a/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8423857338c7943fb53f6d62820e1de9b67a04e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:da9f8de1f3eacbe3b5a5a51aa159e69515d35956d070ed38c2839f2d3b43bc36
+size 4216
diff --git a/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f16bdb6edbb6ed30e5f6ef7fe906ff144b2f106a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:23aeca77e7d6853fed832604c4a0a31c8561cc9cf4b15e1213eda52b86a92596
+size 67606
diff --git a/marked/Y/T-REC-Y.2239-201602-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..77bbe106bfa3d09754976adbd2ec8146935ecd10
--- /dev/null
+++ b/marked/Y/T-REC-Y.2239-201602-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0ac8d07b19c9882838ab8337e3753b0b64c4195bf64ca509e880f7a09bdfb77c
+size 13949
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f400e8248427761242829824e7998843f0816ff6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/09955ff8214ffb6947951fc0f60eb6ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3437894708be97bf79c02cedd3a90f0899cd3ee52b826b8ba16d418d8c68149e
+size 126136
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..02c7152e8fc4d8e23c041fa003934139a058e876
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2dd0fb036fcdbe33057afe8a39673e00f85f773d8ba209fc21454eac422de7b2
+size 142537
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..678410b0172c607d8654993b86268e90527b56fc
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:87cb0792e70a4252886091bbbe0a53322470ddf13a715883568b3efe29cf3216
+size 75632
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a429e7708fa47ff955f8f83ae8fb373178de6743
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9fd0a391bee95b5e8f7a3299d706744cf9fb14b757ce03dd981c606942e596da
+size 52997
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..df82e7e034db70c79eebd6976884d6666e160e02
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9ff01b760050523866d6f5bb5a0a17ddff91138aba9b7d25754eec9ccb326777
+size 65772
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..50ab6e44992eed8ba20413b9e859086a7ff2e3bc
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ff43870a8308cbe4d3fec6c9912176864800afe415f8d40bd38fa54ade6b3979
+size 50563
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..75e71ba710be3e514a3a39e71d69c142e73ef248
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:340bcf1636a75b8c060435917e11273e233eb8622603d5ef21ed18b705c59899
+size 135438
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b6777d0d72025fa80c79b42e318f2f1f6dab46b2
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1e38c8e877a0db349c9869c7a04dbc6d7621d58769668afc10dc76b501101e3b
+size 64247
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..561d2f520d16d759bf02d771cea7f14208564592
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:32d93c075b4424b462afa03ee97852e3a1a273bfd0d8a748285bb4cc5ff6bc8a
+size 72985
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..072f073b6d42cbfa77c827c76c611f286177034a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee72ddf991b7b1d543b2694b1687804845ecb97da77cc35e98e4c7dbf5ac163d
+size 4142
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c75840493fb547158ba82339054e9bb9df4a29fe
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:874ffe155750fc47d9b8a90ee8245e18d750beba8e8c95f5d0ad228a73143985
+size 72315
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4d6ea768eab217ebfbca1dcb39f9f230a152e6fe
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cc81c8124bb31f1561491388e0ed5aa4f82fc1cfe6d649ce506b2df076c69211
+size 112783
diff --git a/marked/Y/T-REC-Y.2241-201709-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7d54e91f92c19847e6024b61f3c4dbd96ac74b0d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2241-201709-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6721869c80faf4c8f000515cf769cd4825c7b46a9fd175fe3090b1779cf1e806
+size 77089
diff --git a/marked/Y/T-REC-Y.2251-201103-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cecdce270a92bdcac867becdffe590473015dc1b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bf081df94762b05acc1ee304962ae200bd52aea971b7ae36366d3637ac8942a6
+size 77844
diff --git a/marked/Y/T-REC-Y.2251-201103-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e0e331fa58e77c4726b9f11994a18565e782d61e
--- /dev/null
+++ b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f3a4976c77d7b71e381c6f4083b64f214d129165ba62e2ee6efc136e391f67f2
+size 3893
diff --git a/marked/Y/T-REC-Y.2251-201103-I_PDF-E/b0211cee4b20034939d883ac0d70f696_img.jpg b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/b0211cee4b20034939d883ac0d70f696_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0bdad0d88cd9d6d390ae48667922437955f23dd4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/b0211cee4b20034939d883ac0d70f696_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee0d53cd414caba7cf48acf492a512bd842f6a2769eab3cb305180dace87bc59
+size 78270
diff --git a/marked/Y/T-REC-Y.2251-201103-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..9f810cf5f697fb67699f0744b97f5e4966a144e4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2251-201103-I_PDF-E/raw.md
@@ -0,0 +1,667 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2251
+
+(03/2011)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Next Generation Networks – Service aspects:
+Interoperability of services and networks in NGN
+
+# --- **Multi-connection requirements**
+
+Recommendation ITU-T Y.2251
+
+# ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+| | |
+|--------------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Numbering, naming and addressing | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Smart ubiquitous networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| Future networks | Y.3000–Y.3099 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# **Recommendation ITU-T Y.2251**
+
+# **Multi-connection requirements**
+
+## **Summary**
+
+In order to support multi-connection capability, new functions are required in the user equipment (UE) and network, such as connection management and coordination, QoS policy control, and access network selection. Recommendation ITU-T Y.2251 describes the requirements to support multi-connection.
+
+## **History**
+
+| Edition | Recommendation | Approval | Study Group |
+|---------|----------------|------------|-------------|
+| 1.0 | ITU-T Y.2251 | 2011-03-16 | 13 |
+
+## **Keywords**
+
+Access network connection, coordination, management, multi-connection, policy.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2012
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|-----------------------------------------------------------------------------|-------------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 3 |
+| 5 | Conventions ..... | 4 |
+| 6 | Multi-connection requirements..... | 4 |
+| | 6.1 Connection management ..... | 6 |
+| | 6.2 Multi-connection registration ..... | 6 |
+| | 6.3 Multi-connection coordination ..... | 6 |
+| | 6.4 Service transfer..... | 6 |
+| | 6.5 Service decomposition and composition ..... | 7 |
+| | 6.6 Multi-connection related policies ..... | 7 |
+| | 6.7 QoS requirements in multi-connection..... | 8 |
+| | 6.8 QoS mapping among different access networks ..... | 8 |
+| | 6.9 Access network selection ..... | 8 |
+| | 6.10 Access network monitoring..... | 8 |
+| | 6.11 Identifying and binding of IP flows..... | 9 |
+| | 6.12 Charging and accounting in multi-connection ..... | 9 |
+| | 6.13 UE function in multi-connection ..... | 9 |
+| | 6.14 IPv4/6 consideration..... | 10 |
+| | 6.15 Energy efficiency and energy/power management in multi-connection..... | 10 |
+| | 6.16 Backward compatibility..... | 10 |
+| | 6.17 Security requirement ..... | 10 |
+| 7 | Security considerations..... | 10 |
+| | Appendix I – QoS mapping among different access networks..... | 11 |
+| | Appendix II – Generic scenarios of multi-connection ..... | 12 |
+| | Appendix III – Policy required for different scenarios ..... | 14 |
+| | Bibliography..... | 15 |
+
+
+
+# Recommendation ITU-T Y.2251
+
+## Multi-connection requirements
+
+# 1 Scope
+
+Multi-connection is the functionality which provides capability to the user equipment (UE) and network to maintain more than one access network connection simultaneously. Furthermore, multi-connection controls and coordinates the media sessions and components across such access network connections.
+
+Different types of access network connections provide users with different user experiences, such as high throughput, low delay, and high security. Multi-connection enables users to utilize any or all of the available access network connections in support of new service scenarios. It is recognized that operators and users will benefit from harmonization of multiple connections, such as efficient utilization of network resources, load balancing, reliability of connection and continuity of services.
+
+This Recommendation describes the requirements of multi-connection and provides a high-level overview of the functionality to be addressed. The descriptions cover aspects related to service requirements, capabilities requirements, functional requirements, and other technology requirements.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Q.1706] | Recommendation ITU-T Q.1706/Y.2801 (2006), Mobility management requirements for NGN . |
+| [ITU-T Q.2981] | Recommendation ITU-T Q.2981 (1999), Broadband integrated services digital network (B-ISDN) and broadband private integrated services network (B-PISN) – Call control protocol . |
+| [ITU-T T.140] | Recommendation ITU-T T.140 (1998), Protocol for multimedia application text conversation . |
+| [ITU-T X.200] | Recommendation ITU-T X.200 (1994) ISO/IEC 7498-1:1994, Information technology – Open Systems Interconnection – Basic Reference Model: The basic model . |
+| [ITU-T Y.1221] | Recommendation ITU-T Y.1221 (2010), Traffic control and congestion control in IP-based networks . |
+| [ITU-T Y.2011] | Recommendation ITU-T Y.2011 (2004), General principles and general reference model for Next Generation Networks . |
+| [ITU-T Y.2012] | Recommendation ITU-T Y.2012 (2010), Functional requirements and architecture of next generation networks . |
+| [ITU-T Y.2051] | Recommendation ITU-T Y.2051 (2008), General overview of IPv6-based NGN . |
+
+| | |
+|----------------|------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.2052] | Recommendation ITU-T Y.2052 (2008), Framework of multi-homing in IPv6-based NGN . |
+| [ITU-T Y.2091] | Recommendation ITU-T Y.2091 (2007), Terms and definitions for Next Generation Networks . |
+| [ITU-T Y.2233] | Recommendation ITU-T Y.2233 (2010), Requirements and framework allowing accounting and charging capabilities in NGN . |
+| [ITU-T Y.2261] | Recommendation ITU-T Y.2261 (2006), PSTN/ISDN evolution to NGN . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 application** [ITU-T Y.2261]: A structured set of capabilities, which provide value-added functionality supported by one or more services, which may be supported by an API interface.
+
+**3.1.2 call** [ITU-T Q.2981]: An association between two or more users using a telecommunication service to communicate through one or more networks.
+
+**3.1.3 connection** [ITU-T X.200]: A connection is an association established for the transfer of data between two or more peer-(N)-entities. This association binds the peer-(N)-entities together with the (N-1)-entities in the next lower layer.
+
+**3.1.4 handover** [ITU-T Q.1706]: The ability to provide services with some impact on their service level agreements to a moving object during and after movement.
+
+**3.1.5 IP flow** [ITU-T Y.1221]: An IP flow at a given interface is defined as the occurrence at that interface of the set of IP packets which match a given classification. An IP flow may consist of packets from a single application session, or it may be an aggregation comprising the combined traffic from a number of application sessions. When a classification may be subdivided into different sub-classifications (separate or overlapping), different IP subflows may be recognized in the corresponding IP flow.
+
+**3.1.6 service continuity** [ITU-T Q.1706]: The ability for a moving object to maintain ongoing service over including current states, such as user's network environment and session for a service.
+
+**3.1.7 session** [ITU-T T.140]: A logical connection between two or more user terminals for the purpose of exchanging information in text format on a real-time basis.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 multi-connection:** The functionality which provides capability to the user equipment (UE) and network to maintain more than one access network connection simultaneously.
+
+NOTE 1 – All connections are coordinated to provide service to higher layer entities.
+
+NOTE 2 – In a multi-connection communications at least one UE is required to be a multi-connection UE.
+
+**3.2.2 service component:** Part of a service which cannot be further decomposed.
+
+**3.2.3 service decomposition:** Act of decomposing a service into several service components.
+
+NOTE – The original service logic can be restructured transparently to the end user and application.
+
+**3.2.4 service transfer:** Act of moving, one or more services or service components belonging to a single multi-connection UE, from one access network associated with one interface of the multi-connection UE to another access network(s) associated with other interface(s) of the multi-connection UE.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|-------------------------------------------------|
+| 2G | Second Generation wireless telephone technology |
+| 3G | Third Generation wireless telephone technology |
+| 3GPP | 3rd Generation Partnership Project |
+| AP | Access Point |
+| API | Application Programming Interface |
+| BSS | Base Station Subsystem |
+| CPU | Central Processing Unit |
+| CS | Circuit Switched |
+| DHCP | Dynamic Host Configuration Protocol |
+| DNS | Domain Name System |
+| FTP | File Transfer Protocol |
+| GPRS | General Packet Radio Service |
+| GSM | Global System for Mobile communications |
+| IP | Internet Protocol |
+| LTE | 3GPP Long Term Evolution |
+| MCS | Modulation and Coding Scheme |
+| MPLS | MultiProtocol Label Switching |
+| NGN | Next Generation Network |
+| PC | Personal Computer |
+| PPP | Pont-to-Point Protocol |
+| PS | Packet Switched |
+| QoS | Quality of Service |
+| RED | Random Early Detection |
+| RSS | Received Signal Strength |
+| RTP | Real-time Transport Protocol |
+| SP | Strict Priority |
+| UE | User Equipment |
+| UMTS | Universal Mobile Telecommunications System |
+| VoD | Video on Demand |
+| VoIP | Voice over IP |
+| VPN | Virtual Private Network |
+| WFQ | Weighted Fair Queue |
+| WiMax | Worldwide Interoperability for Microwave Access |
+| WLAN | Wireless Local Area Network |
+| WRR | Weighted Round Robin |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance with this Recommendation is to be claimed.
+
+The keywords "is prohibited from" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance with this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement need not be present to claim conformance.
+
+The keywords "is not recommended" indicate a requirement which is not recommended but which is not specifically prohibited. Thus, conformance with this Recommendation can still be claimed even if this requirement is present.
+
+The keywords "can optionally" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with this Recommendation.
+
+# 6 Multi-connection requirements
+
+The multi-connection capability facilitates realization of the use cases described in [b-ITU-T Y-Sup.9], such as balancing network load, higher throughput via connection aggregation or service transfer across connections. Take video conferencing as an example, the voice may be carried by a 2G or 3G network to assure real-time service via a circuit switch network, while the video component may be transmitted via the wireless local area network (WLAN).
+
+Figure 6-1 shows the generic multi-connection scenarios defined in multi-connection scenario supplement [b-ITU-T Y-Sup.9], see also in Appendix II. Requirements covering scenarios B, C, D and E of [b-ITU-T Y-Sup.9] are described in this Recommendation. Scenario A is shown in the figure for completeness.
+
+
+
+```
+graph TD
+ subgraph A
+ A_App[Application] --> A_SC[Service control]
+ A_SC --> A_AC[Access control]
+ A_AC --> A_AP[Access point]
+ A_AP --> A_UE[UE]
+ end
+ subgraph B
+ B_App[Application] --> B_SC[Service control]
+ B_SC --> B_AC[Access control]
+ B_AC --> B_AP1[Access point]
+ B_AC --> B_AP2[Access point]
+ B_AP1 --> B_UE[UE]
+ B_AP2 --> B_UE
+ end
+ subgraph C
+ C_App[Application] --> C_SC[Service control]
+ C_SC --> C_AC1[Access control]
+ C_SC --> C_AC2[Access control]
+ C_AC1 --> C_AP1[Access point]
+ C_AC2 --> C_AP2[Access point]
+ C_AP1 --> C_UE[UE]
+ C_AP2 --> C_UE
+ end
+ subgraph D
+ D_App[Application] --> D_SC1[Service control]
+ D_App --> D_SC2[Service control]
+ D_SC1 --> D_AC1[Access control]
+ D_SC2 --> D_AC2[Access control]
+ D_AC1 --> D_AP1[Access point]
+ D_AC2 --> D_AP2[Access point]
+ D_AP1 --> D_UE[UE]
+ D_AP2 --> D_UE
+ end
+ subgraph E
+ E_A1[Applica tion] --> E_SC1[Service control]
+ E_A2[Applica tion] --> E_SC2[Service control]
+ E_SC1 --> E_AC1[Access control]
+ E_SC2 --> E_AC2[Access control]
+ E_AC1 --> E_AP1[Access point]
+ E_AC2 --> E_AP2[Access point]
+ E_AP1 --> E_UE[UE]
+ E_AP2 --> E_UE
+ end
+```
+
+Figure 6-1: Generic multi-connection scenarios. The diagram shows five scenarios (A, B, C, D, E) illustrating the flow from Application to UE. Scenario A: One Application connects to one Service control, then one Access control, then one Access point, and finally to the UE. Scenario B: One Application connects to one Service control, then one Access control, which then connects to two Access points, both of which connect to the UE. Scenario C: One Application connects to one Service control, which then connects to two Access controls, each of which connects to one Access point, both of which connect to the UE. Scenario D: One Application connects to two Service controls, each of which connects to one Access control, each of which connects to one Access point, both of which connect to the UE. Scenario E: Two Applications each connect to one Service control, each of which connects to one Access control, each of which connects to one Access point, both of which connect to the UE.
+
+Figure 6-1 – Generic multi-connection scenarios
+
+## 1) Scenario A
+
+In this scenario, one user equipment (UE) accesses simultaneously one access point (AP) (e.g. BSS, NodeB, eNodeB) via multiple frequency bands. By accessing one AP via multiple frequencies, higher peak data rate can be provided to the UE. This is useful to provide higher data rate service and optimized user experience. This is similar in concept to softer handover or carrier aggregation.
+
+## 2) Scenario B
+
+In this scenario, the UE can access multiple access points simultaneously using the same access technology. This scenario provides performance improvement to the user, especially to the user in the cell edge, where the interference can be eliminated based on the coordination of different APs. This is similar in concept to soft handover.
+
+## 3) Scenario C
+
+In this scenario, the UE connects to heterogeneous access networks which are controlled by different access control functions, but the same service control function. The access control management and the QoS policies are enforced in each access control function and established by the service control point. In this scenario, data flows can be transmitted over different access network connections in a coordinated manner.
+
+For example, in the video conference, the voice is transmitted by 2G, 3G, or LTE to assure real-time service, and the video is transmitted by WLAN; both of these two access networks use the same core network. Data flows can also be transmitted over the combined bit rate of the multiple access network connections to increase throughput.
+
+For example, the user is downloading a multi-media file with a large volume of data. To improve the downloading rate and to balance the data downloading, the user accesses additional access network connections to increase the bit rate.
+
+## 4) Scenario D
+
+In this scenario, a UE connects to multiple heterogeneous access networks controlled by separate access control and service control functions. The UE and network combine the different flows at the application layer.
+
+For example, Sophie has dialled into an application providing unified communications to her company over an LTE network. She indicates to the application the need to share a media presentation. The application coordinates Sophie's UE to simultaneously use WLAN for the file sharing component.
+
+## 5) Scenario E
+
+In this scenario, a UE connects to multiple heterogeneous access networks through multiple access points, which are controlled by separate access control and service control functions for different applications. In this scenario, a specific application is bound to use a specific network connection. A UE can be treated as a set of single-interface UEs which support different access technologies and utilize various applications respectively, but service transfer between different connections should be considered in this scenario.
+
+For example, if the UE connects to the company intranet through a virtual private network (VPN) connection over WLAN, and the user wants to monitor the stock market as well, which is not allowed on the intranet, it is necessary to use the 2G connection to access the stock application at the same time.
+
+The following subclauses identify the requirements for multi-connection capability. These requirements address UE requirements as well as network requirements.
+
+## **6.1 Connection management**
+
+The connection management capability is used by a multi-connection UE and a multi-connection capable network to establish, release, and modify connections. The capability is required to manage all connections in their entirety to provide unified control to support the multi-connection use cases described in [b-ITU-T Y-Sup.9], e.g. load balance.
+
+NOTE – Connection management is different from the traditional resource management supported in single-connection networks.
+
+## **6.2 Multi-connection registration**
+
+In the multi-connection environment, a UE with multi-connection capability is required to register to the multi-connection capable network. The following is also required:
+
+- 1) A multi-connection UE is required to de-register all active connections of a given service when terminating this service.
+- 2) Access network information (i.e., attributes) is required to be provided to the core network during the registration procedure.
+- 3) A multi-connection identifier unique in the UE scope is required to identify each connection belonging to the same UE.
+
+## **6.3 Multi-connection coordination**
+
+Different types of mobile communication schemes have different characteristics and coverage. In the migration phase to the 3G and LTE, network deployment is not always fully consistent with existing network coverage. Existing 2G (GSM) networks provide stable coverage in comparison to 3G and LTE. Therefore, it can be desirable to utilize the circuit switched domain in 2G for the voice application, while data applications utilize the packet switched domain (WLAN, 3G, WiMAX or LTE), the so-called multi-connection coordination. This strategy will help offload data intensive applications from 2G. As a result, the following is required:
+
+- 1) The network is required to support voice applications in the circuit switched (CS) domain and data applications in the packet switched (PS) domain. This separation of CS and PS traffic types shall be able to operate concurrently.
+- 2) The network and UE are required to support the CS and PS applications running simultaneously over different access technologies.
+
+## **6.4 Service transfer**
+
+In the multi-connection environment, the UE may have more than one active connection simultaneously to different access network connections.
+
+In case of network congestion or loss of radio signal in the access network connections, the network is required to dynamically control the user access and resource allocation to obtain the optimal distribution of applications and/or IP flows. This is achieved according to multi-connection policies generated by both the user and network.
+
+Service transfer is one mechanism required to achieve this capability thus further providing service continuity to the user and application during the service transfer. Summarizing these requirements:
+
+- 1) Service continuity is required during service transfer, in order to minimize the time taken during radio handover or new bearer establishment.
+- 2) A resource pre-allocation mechanism is required to reduce the time of the service transfer.
+- 3) A data forwarding mechanism is also required to keep data integrity.
+
+NOTE – The service transfer depends on the scenario, operators, users, the properties of the application and service.
+
+## **6.5 Service decomposition and composition**
+
+Service decomposition is required to support a number of scenarios provided in [b-ITU-T Y-Sup.9]. A service supported by the multi-connection capability can be split into several service components in order to be transmitted through different access network connections.
+
+Likewise, service composition is required to support a number of scenarios provided in [b-ITU-T Y-Sup.9]. Thus, the service components in a call split through different access network connections can be composed into one service in a unified way to be transmitted in one or a lesser number of access network connection(s).
+
+The following encompasses additional requirements applicable to service composition and decomposition, it is required to:
+
+- 1) Maintain the previous state in the service after composing or decomposing the service.
+- 2) Synchronize the service components belonging to one application while in the process of composing or decomposing a service; e.g., the packet rates of the different service components requiring synchronization.
+- 3) Assign a unique identifier to each service component in order to identify the decomposed and composed service.
+- 4) Add or remove a new service component into/from an active call.
+
+## **6.6 Multi-connection related policies**
+
+Policy is needed to determine how to use multiple access network connections. There can be several kinds of policies deployed in the multi-connection capability. Each layer may have its own policy for choosing the related connections. Therefore, it is necessary to have a coordination mechanism to ensure that all policies can work together in a coherent manner. The following policies are required to be supported in a multi-connection environment:
+
+- 1) QoS policy – This policy is used to match the service and its access network connections with equivalent quality. It is also used as a factor to be considered in the access network selection.
+- 2) Access network selection policy for data sending and receiving – This policy is based on application, service, user preference, operator policy, security consideration, access network status and availability.
+- 3) Service transfer policy – Transferring a service between multiple accesses is required to be validated by the operator's policies. These policies include:
+ - Access related policy: For example, a given service may be transferred between specific access technologies, but such transfer of a service may be forbidden or restricted on some other access technologies;
+ - Service component related policy: For example, only some service components are eligible to service transfer such as service components (e.g., voice or video) having high QoS requirements, while other service components may not be eligible to service transfer.
+ - Subscriber related policy: Service transfer may be applicable only to certain types of subscribers, not for all subscribers.
+
+The use of the above policies varies depending on the specific scenarios of multi-connection. Appendix III provides an analysis of how these policies can be used in the scenarios described in [b-ITU-T Y-Sup.9].
+
+## **6.7 QoS requirements in multi-connection**
+
+In a multi-connection capable network, the UE and the network are required to be aware of the interactions created by the number of simultaneous accesses provided to the application and therefore each associated QoS. The combination or resulting QoS is required to portray the combined QoS involved in each specific service component.
+
+Specifically, some QoS multi-connection requirements for the multi-connection scenario described in [b-ITU-T Y-Sup.9] are:
+
+- 1) In Scenarios A, B, and C, service control is required to provide to the application a resulting QoS that is at least as good as the QoS of any individual access technology under its control.
+- 2) In Scenarios A, and B, access control is required to deliver access technology QoS to the service control that is at least as good as QoS of any individual access link under its control.
+
+In Scenario A, the access point is required to deliver QoS to the access control that is at least as good as the QoS of any individual access link under its control.
+
+## **6.8 QoS mapping among different access networks**
+
+Different access technologies have different link-layer QoS mechanisms. The multi-connection communication requires mechanisms to minimize service degradation among multi-connections. According to the QoS policies specified for each access technology (i.e., [b-IEEE 802.16], [b-IEEE 802.11], GPRS, UMTS, and LTE), QoS classes are required to be allocated both for the service components and for their respective accesses. The bandwidth is required to be constrained by the mapping policy of the QoS management. An example of such mapping is provided in Appendix I.
+
+## **6.9 Access network selection**
+
+Access network selection includes discovery and selection [b-IETF RFC 5113]. In a multi-connection environment, discovery of an access network can use existing access network discovery mechanisms developed in IETF, IEEE or 3GPP. However, choosing the best access networks needs more capabilities. Due to the characteristics of multi-connections, not only a single access network but also multiple access networks can be chosen. Choosing the best ones needs more complicated but efficient capabilities to support various QoS and policy mechanisms.
+
+Access network selection of multi-connection is required to provide consistent QoS, overall network stability (load balance) and user satisfaction (select access technology based on end-user's preference). In selecting the discovered access networks, the following considerations are required:
+
+- 1) The QoS requirements of the flows, e.g., bandwidth, delay or loss rate.
+- 2) The capabilities and availability of the UE, e.g., memory, battery, CPU or available interface.
+- 3) The capabilities and availability of access resources, e.g., access technology type, bandwidth, loss rate, delay, jitter, power consumptions or received signal strength (RSS).
+- 4) The load-status of the access network, e.g., number of users.
+- 5) User's preferences, e.g., cost, interface preference.
+- 6) Operator's policies described in clause 6.6.
+
+## **6.10 Access network monitoring**
+
+In order to efficiently provide access network selection or changing of a currently active access network, the status information of the currently active access network needs to be monitored, such as physical layer parameters including available bandwidth, modulation and coding scheme (MCS)
+
+level, radio strength status. The access network information is required to be forwarded to the appropriate functions, periodically or on demand.
+
+## **6.11 Identifying and binding of IP flows**
+
+Support of multiple connections in the IP network faces problems, such as identifying IP flows and binding them to different access network connections. To solve these problems, the following is required:
+
+- 1) Classifying of IP flows – All packets belonging to a particular flow are required to have a set of properties. These properties are defined as follows:
+ - One or more packet header field (e.g., destination IP address), transport header field (e.g., destination port number), or application header field (e.g., RTP header fields).
+ - One or more characteristics of the packet (e.g., number of MPLS labels).
+ - One or more fields derived from packet treatment (e.g., next hop IP address or the output interface).
+
+A packet is defined to belong to a flow if it completely satisfies all the defined properties of the flow.
+
+- 2) Identifying of IP flows – In the multi-connections environment, the UE and network need to distinguish IP flows. It is required to classify all kinds of current identifiers of the UE, service data and user, such as IP address, and then choose a proper one or design a new one to identify the IP flows in a multi-connection environment.
+- 3) Binding of IP flows – The connections are used to carry certain IP flows, so IP flows marked by their identifiers are required to be bound to proper connections.
+
+## **6.12 Charging and accounting in multi-connection**
+
+The charging and accounting are required to support the operator's need to collect and process information, such that users can be charged for the services provided in the multi-connection environment. Based on the NGN charging requirements [ITU-T Y.2233], in the multi-connection environment, it is also required to provide aggregated charging; i.e., the utilization of each connection is considered, and the sum of all connections' utilization determines the ultimate charging data for the user. The detailed requirements are summarized below:
+
+- 1) Offline charging or online charging is required to be supported in multi-connection. They support the collection of data for later processing (offline charging), as well as near-real-time interactions with applications, such as for pre-paid services (online charging).
+- 2) In the multi-connection environment, each connection may have its own charging information, and charging information needs to be aggregated to determine total charging information. Aggregation of charging information is required in multi-connection.
+
+## **6.13 UE function in multi-connection**
+
+In a multi-connection environment, the following are to be supported by the multi-connection UE.
+
+- 1) A multi-connection UE is required to maintain multiple simultaneous access network connections.
+- 2) A multi-connection UE is required to map IP flows to different access network connections.
+- 3) A multi-connection UE can optionally receive configuration parameters from each of its access networks through various mechanisms such as DHCP and PPP. Some of the available parameters are specific to a specific interface, such as the IP address. Others are specific to the network node, such as the routing information (e.g., gateway), DNS servers' or IP addresses. Configuration harmonization in terms of DHCP, PPP, and DNS among others is required to avoid configuration conflicts.
+
+- 4) Adjustment of packet rates is required to be provided for the different IP flows belonging to the same application between different connections when services are decomposed.
+- 5) A multi-connection UE is required to support IPv4 only, IPv6 only, or dual-stacks.
+
+## **6.14 IPv4/6 consideration**
+
+According to IPv6-based NGN defined in [ITU-T Y.2051], IPv6 impacts to NGN cover not only the UE side but also the network side. In the multi-connection environment, it is required to support IPv4 and IPv6 dual stack and simultaneous usage thereof.
+
+## **6.15 Energy efficiency and energy/power management in multi-connection**
+
+It is recommended to pursue energy efficiency in the multi-connection network, both in the network infrastructure and in the UE.
+
+In order to reduce the battery consumption of the multi-connection UEs, the energy/power management mechanisms (e.g., in idle mode, sleeping mode, and active mode) are required to be supported on each interface supported by the multi-connection UE.
+
+## **6.16 Backward compatibility**
+
+The multi-connection capability is required to be backward compatible. When deployed in legacy networks, it is required to interoperate with ordinary network equipment and user equipment (i.e., single-connection technology).
+
+## **6.17 Security requirement**
+
+Security requirements such as access control, authentication, non-repudiation, data confidentiality, communication security, data integrity, availability, and privacy are required across all connections.
+
+- 1) Protection against unauthorized use of multi-connection capability;
+- 2) Mechanisms for data confidentiality among multiple accesses when necessary. The data contains the user's profile in each connection, e.g., preferences, profiles, presence, availability and location information;
+- 3) Mechanisms for data integrity in the case that the data of an application is delivered through several connections;
+- 4) Mechanisms of non-repudiation for preventing one of the connection in a communication from falsely denying having participated in multi-connection communication;
+- 5) Protection to minimize faked connection registration, and the hostile attack by one of the connections;
+- 6) Mechanisms of protecting the data transferred in one connection from the attack of another connection when each connection has different security level;
+- 7) Protection against unauthorized updates to operator's and user's multi-connection policies on the UE;
+- 8) Secure storage, handling and enforcement of operator's and user's multi-connection policies on the UE;
+- 9) A security coordination function is required to coordinate each and all involved accesses according to multi-connection operator's predefined security policies and that of the user.
+
+# **7 Security considerations**
+
+Security requirements are provided in clause 6.17.
+
+# Appendix I
+
+## QoS mapping among different access networks
+
+(This appendix does not form an integral part of this Recommendation.)
+
+In order to minimize service degradation among multi-connections, the QoS classes need to be mapped with the same or similar classes. According to the QoS policies specified in each standard (i.e., [b-IEEE 802.16], [b-IEEE 802.11], GPRS, UMTS, and LTE), traffic is required to be allocated both for the service flows and the queues. The bandwidth is required to be constrained by the mapping policy of QoS management. Table I.1 shows the example of QoS mapping.
+
+After the mapping, scheduling policy is required to be performed, such as strict priority (SP), weighted round robin (WRR) or weighted fair queue (WFQ). Congestion control policy is also required to be performed, such as tail-drop, random early detection (RED). Buffer size is also required to be taken into consideration.
+
+**Table I.1 – Example of QoS Mapping among different access networks**
+
+| Priority | [b-IEEE 802.16] | b-IEEE 802.11] | GSM/GPRS | UMTS/LTE | Services |
+|----------|-----------------|----------------|-----------------|-----------------------------|---------------------|
+| 0 | BE | AC_BK | Delay class 4 | Background (QCI = 9) | E-mail |
+| 1 | BE | AC_BK | Delay class 1-3 | Interactive (QCI = 8) | Web |
+| 2 | nrtPS | AC_BE | Delay class 1-3 | Interactive (QCI = 7) | FTP (low quality) |
+| 3 | nrtPS | AC_BE | Delay class 1-3 | Interactive (QCI = 5, 6) | FTP (high quality) |
+| 4 | rtPS | AC_VI | Delay class 1 | Streaming (QCI = 4) | VoD |
+| 5 | ertPS | AC_VI | Delay class 1 | Streaming (QCI = 4) | Real-time streaming |
+| 6 | UGS | AC_VO | Delay class 1 | Conversational (QCI = 2, 3) | VoIP (low quality) |
+| 7 | UGS | AC_VO | Delay class 1 | Conversational (QCI = 1) | VoIP (high quality) |
+
+# Appendix II
+
+## Generic scenarios of multi-connection
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Multi-connection scenarios are shown but not limited to the ones depicted in Figure 6-1. The general principles of all multi-connection scenarios are summarized as follows:
+
+- 1) All multi-connection scenarios are based on UEs having multiple physical interfaces, which mean scenarios with single physical interface are not in the scope of multi-connection.
+- 2) The following cases are not considered as multi-connection scenarios:
+ - Dual mode cell phones which must disable one radio module in order to use the second.
+ - Handover.
+- 3) In multi-connection scenarios, the multiple network entities belonging to different connections may interwork.
+- 4) The layers in the multi-connection scenarios are the logic layers, but not the physical layers.
+
+
+
+The diagram illustrates five generic multi-connection scenarios (A, B, C, D, E) showing the logical architecture. Each scenario consists of a UE at the bottom, connected to one or more Access Points (APs). Above the APs are the Access Control (AC) and Service Control (SC) layers, and at the top is the Application layer.
+
+- Scenario A:** One UE connected to one AP. The AP has one AC layer, which connects to one SC layer, which connects to one Application layer.
+- Scenario B:** One UE connected to two APs. Each AP has its own AC layer, both of which connect to a single SC layer, which connects to one Application layer.
+- Scenario C:** One UE connected to two APs. Each AP has its own AC and SC layers, both of which connect to a single Application layer.
+- Scenario D:** One UE connected to two APs. Each AP has its own AC and SC layers, connected to two separate Application layers.
+- Scenario E:** Two separate UEs, each connected to one AP. Each AP has its own AC and SC layers, connected to two separate Application layers.
+
+Figure II.1 – Generic multi-connection scenarios. The diagram illustrates five scenarios (A, B, C, D, E) showing the logical architecture of multi-connection. Each scenario consists of a UE at the bottom, connected to one or more Access Points (APs). Above the APs are the Access Control (AC) and Service Control (SC) layers, and at the top is the Application layer. Scenario A: One UE connected to one AP, which has one AC and one SC layer, connected to one Application layer. Scenario B: One UE connected to two APs, each with its own AC layer, both connected to a single SC layer, which is connected to one Application layer. Scenario C: One UE connected to two APs, each with its own AC and SC layers, both connected to a single Application layer. Scenario D: One UE connected to two APs, each with its own AC and SC layers, connected to two separate Application layers. Scenario E: Two separate UEs, each connected to one AP with its own AC and SC layers, connected to two separate Application layers.
+
+**Figure II.1 – Generic multi-connection scenarios**
+
+### 1) Scenario A
+
+In this scenario, one UE accesses one access point (e.g., BSS, NodeB or eNodeB) via multiple frequency bands simultaneously. By accessing one AP via multiple frequencies, higher peak data rate can be provided to the UE. This is useful to provide higher data rate service and optimized user experience, and also trunking efficiency can be increased, which helps to improve resource utilization.
+
+### 2) Scenario B
+
+In this scenario, the UE can access multiple access points simultaneously using the same access technology. This scenario provides performance improvements to the user, especially to the user in the cell edge, where the interference can be eliminated based on the coordination of different APs. Availability and use of this scenario depends on broad deployment of multiple antenna technology.
+
+### 3) Scenario C
+
+In this scenario, the UE connects to heterogeneous access networks which are controlled by different access control functions but the same service control function. The access control management and the QoS policies are enforced in each access control function and established by the service control point. In this scenario, data flows can be transmitted over different access networks to obtain different QoS assurance.
+
+For example, in the video conference, the voice is transmitted by 2G, 3G or LTE to assure real-time service, and the video is transmitted by WLAN, which has higher bandwidth and may be cost efficient for a large number of network flows; both of these two access networks use the same core network. Data flows can also be conveyed by different access networks to increase bandwidth.
+
+For example, the user is downloading a multimedia file with a large volume of data. To improve the downloading rate and to balance the data downloading, the user accesses additional access networks to increase the bit rate.
+
+### 4) Scenario D
+
+Scenario D shows a UE connecting to multiple heterogeneous access networks controlled by separate access control and service control functions. The UE can combine the different network capabilities to serve a unified application.
+
+For example, the UE has both 2G and WLAN connections; when the video telephone application is launched, the voice will use the 2G connection to ensure a stable and real-time voice service, and the WLAN connection will be used to get larger bandwidth for video. However, the UE may connect to a 2G base station and a WLAN AP simultaneously, and the video telephone application running in the UE may thus have multiple sessions controlled by different networks.
+
+### 5) Scenario E
+
+In this scenario, a UE connects to multiple heterogeneous access networks through multiple access points, which are controlled by separate access control and service control functions for different applications. In this scenario, a specific application is bound to use a specific network connection. A UE can be treated as a set of single-interface UEs which support different access technologies and utilize various applications respectively, but service transfer between different connections should be considered in this scenario.
+
+For example, if the UE connects to the company intranet through a VPN connection over WLAN, and the user wants to monitor the stock market as well, which is not allowed on the intranet, it is necessary to use the 2G connection to access the stock application at the same time.
+
+# **Appendix III**
+
+## **Policy required for different scenarios**
+
+(This appendix does not form an integral part of this Recommendation.)
+
+When analysing the five scenarios introduced in [b-ITU-T Y-Sup.9]; i.e., scenarios A, B, C, D, and E, it is recognized that they entail different policy functionality according to the involved radio access technologies, access control, service control, and applications' requirements.
+
+Different policy requirements are applicable on a scenario-wise approach as outlined below:
+
+### 1) Networks supporting Scenario B
+
+Networks supporting scenario B are required to include an access policy capability. The access policy capability is required to support policies for meeting QoS requested by the access technology through aggregation of the multiple available access points.
+
+### 2) Networks supporting Scenario C
+
+Networks supporting scenario C are required to include a QoS policy capability. The QoS policy capability is required to support policies for meeting application QoS by appropriately using the QoS offered by the various available access technologies.
+
+### 3) Networks supporting Scenario D
+
+Networks supporting scenario D are required to include an application policy interface. The application policy interface is required to provide an interface to the application's multi-connection policy function.
+
+### 4) Policy requirements common to all scenarios
+
+Some policy requirements are considered common to all five scenarios, some of these are:
+
+- The multi-connection network is required to be able to communicate policies to the UE directly or via the multi-connection service control function.
+- Multi-connection network is required to include a policy coordination function for the coordination of the multiple policy entities present in the network.
+
+# Bibliography
+
+- [b-ITU-T Y-Sup.9] ITU-T Y-Series Recommendations – Supplement 9 (2010), *ITU-T Y.2000-series – Supplement on multi-connection scenarios*.
+- [b-IEEE 802.11] IEEE 802.11-2011, *IEEE Standard for Information Technology – Telecommunications and Information Exchange Between Systems – Local and Metropolitan Area Networks – Specific Requirements Part 11: Wireless LAN Medium Access Control and Physical Layer (PHY) Specification*.
+- [b-IEEE 802.16] IEEE 802.16-2009, *IEEE Standard for Local and Metropolitan Area Networks –Part 16: Air Interface for Broadband Wireless Access Systems*.
+- [b-IETF RFC 5113] IETF RFC 5113 (2008), *Network Discovery and Selection Problem*.
+
+
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/1c29dadab94c3fa552d270434db09c81_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/1c29dadab94c3fa552d270434db09c81_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6300c2a66bd4e6df82e1019f06b9a2e7a3006fa1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/1c29dadab94c3fa552d270434db09c81_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:414c20f0e1675063cdbe92df16717d45d1a55a9abfa8758c4f9c26e4ed741cc4
+size 67242
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/27091c6f4ef4a37992edfa7ef3f4776a_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/27091c6f4ef4a37992edfa7ef3f4776a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6ea8b0e088184d90a8abef046143a13d8c82e659
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/27091c6f4ef4a37992edfa7ef3f4776a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a101610fb4d49f098c0bd48c505ed15ca91e7e06786c5480599047a48d36ec18
+size 12422
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2ae3eae1bd80a90f192f568ae246a9a6_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2ae3eae1bd80a90f192f568ae246a9a6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8dcf8552a8057dbbcd3ceb4d9cbe362c431abe65
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2ae3eae1bd80a90f192f568ae246a9a6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:92b5a11d7bc6f3f3c6c6ff518aa2d89f22481a924e998d16ebd1d81b49421940
+size 69906
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6500a082343749b3ea70f57a85b88921914ed9b6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/2eb23c2210154279f8013a1594fbcc5a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:15268a5eaa536b548463ac8fd33982f982c330cd9edaf9550526d0f6038d26bd
+size 72105
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/33d125d70090f24185c6115a2693dc04_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/33d125d70090f24185c6115a2693dc04_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..af9a50ffff768a9c0b663819092fef7f4dde3bf7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/33d125d70090f24185c6115a2693dc04_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fd880ceac38e6e852f7cb9dd730ede55f4ecb39c8e10d0da360c9c0509625287
+size 11784
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/421fc75480c21e7ebb25756826652367_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/421fc75480c21e7ebb25756826652367_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..68ee75f50d05cf9668349371ca2ab53697949426
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/421fc75480c21e7ebb25756826652367_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5ac93adccf78f97ca4704746cee2406b78bc4ac44a640cee9af288ca32423670
+size 25356
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/4cc7cdce3d498d8b0ba033a9be24ade5_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/4cc7cdce3d498d8b0ba033a9be24ade5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..df67829ac3b327b2156befa565e09f0e4277c446
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/4cc7cdce3d498d8b0ba033a9be24ade5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a7af5745e38f94468430517e065038ece3afca98a224f4607e4121f0ff8d3821
+size 18499
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d7ea286295d78c99e37521dafa83906eef37955a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2d5e1cec0065ab82ee2a26aade3dbc9b4ac03867b9fec178f7f400c083c354d5
+size 83426
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/567dc35a62fbc3da7816e9f5c455a3a6_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/567dc35a62fbc3da7816e9f5c455a3a6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6ff985dee7401a2c4a2cdbd97fc4924fbb7478be
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/567dc35a62fbc3da7816e9f5c455a3a6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b103fb6388f740e1aa1d685ee436da7708804552551c0ea311af1b4d97a5b9da
+size 12304
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6674628098741988aeb5fc3ca9a86e09f296c685
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0cac10c80cd6ba06534c42aa23a4c3307d48179eed566a22ec41a0c73eea8248
+size 26610
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..11cf181326badb4c381d85d7f8abaa93f4cf8eaa
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:89f4f297e7318c50337da6964474093b8768c6e193dcf7c7edc212d52e9be4b4
+size 103810
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c44ad589cd23854de0326146b710e4ea75f570c4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:03467c882a01b3f522921253c60d2961edbc1ee5739097f22bda8ac436571682
+size 8256
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/90ddf538ef276510e2b631f7b96654e6_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/90ddf538ef276510e2b631f7b96654e6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ec6be7012250d2a3326b1a36fb13c90a3b141240
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/90ddf538ef276510e2b631f7b96654e6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:79cc2ef2d4f0a259b1695b5b084976f4b4013a3bae2bc0f064b635ff60023ff8
+size 26659
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a308c9f371cebf64937550609515b89a_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a308c9f371cebf64937550609515b89a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6a2ff17ecdf365fb07a81e92aaffd1a741634ee1
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a308c9f371cebf64937550609515b89a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7c5ffb039ecb1efcf32a2b4b24c66f84d6519eb27c2670ddcb72630a04473c91
+size 12336
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..978b201c5f234d5a3656f485a93db1e8da058cd3
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8a789dd29e4757cc22ee59a222ad7f691d4506c9df7107efd743de03cea77d4c
+size 19158
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/b8a0ff1e55389a5ca2f3570c57548041_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/b8a0ff1e55389a5ca2f3570c57548041_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c91d47adfed4a629a670367414e099946c8705a4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/b8a0ff1e55389a5ca2f3570c57548041_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:68198f3f8bc6ffedbf06ae88822f1326bba761debffb448d7e2059860c6a4b75
+size 12125
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/c5655e700cc3e9aac7e9f4f07f30264d_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/c5655e700cc3e9aac7e9f4f07f30264d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..917a43cf370b6aad9566438cf808f9ee673d672d
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/c5655e700cc3e9aac7e9f4f07f30264d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5d3bc66d8ae642954050e6b70bbdb585c55faa0e76728172ee95035a94b46c0a
+size 38878
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/ceb48bd7cc8cbb0fa401b366532bbdb0_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/ceb48bd7cc8cbb0fa401b366532bbdb0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7a86f2032e7fb3414f44130659b1a755db521691
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/ceb48bd7cc8cbb0fa401b366532bbdb0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f892cb53c95e5929556135cc73626aee09dde78249eca22adf4f216a9b8f54a4
+size 55580
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..538229b3581104b989c957a3235b29774ad9a188
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:37a3e72b018f7a2a27151f5aa54ec092dab894db5e2fc7e1172f5e985c770b39
+size 121453
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2f96a5cd0567f10800e5f84da2da4ea40055ac19
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d046fad60d983fa2a0f57393c96beb61c7a6c3d41a02352d949f58e4284dae0d
+size 27000
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/e180f2b5fcbe8001554a7c0677cd3f82_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/e180f2b5fcbe8001554a7c0677cd3f82_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c3cdb9bd8398e2926fa1881e2fd269e24e4799eb
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/e180f2b5fcbe8001554a7c0677cd3f82_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6d7389ef182a157b86248e6da792b11a5c30936438766245b32c9620e26a482a
+size 25273
diff --git a/marked/Y/T-REC-Y.2262-200612-I_PDF-E/f0367f317ffaf58c722285085a21855b_img.jpg b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/f0367f317ffaf58c722285085a21855b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..05bfd1ac69718b7f92cfbf8aef76fabf3cb3f340
--- /dev/null
+++ b/marked/Y/T-REC-Y.2262-200612-I_PDF-E/f0367f317ffaf58c722285085a21855b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3b3a5a4a1e8d08aece5c2db5a9e56edcf529b257b7c2ac690af1e0e761d01f94
+size 11636
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..22a87b0694d727f9cbb330e9fd00685e42e90bcd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:347febf35b7f46279429672d92b09e30ff0c351ae9690dec0d0a9de177124af6
+size 23890
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b4a990064e3ab86c1dbe0c793a99350b2c742aaf
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d00a51e083e23b54052fff9fef58b7a04acac13145432d134e71e0c2b0ee2000
+size 35649
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1a62ed1322f07ee430bdebac89c4e24855f1d350
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:81ef9119bf9b8e3c277a9f764d62ceba9990a860def86a83a1fa1ae7b3a67f06
+size 16212
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ea6a930d45ded30214c3adb6299689a1c76ce072
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4298b14bb06a4a6e9bca133fdd80ac06aaebb53715aaa3baba5ce00ed95b9dbb
+size 72014
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..252da22edaa446b7b5fdb574889cd7a8ccba773a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:84d30cd0511ae1559a7334be06f6c73001e8e4b4768f3cc6c94780b5fdf9d232
+size 67970
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5ebcf382a6ee952d6c5b8b948415801e_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5ebcf382a6ee952d6c5b8b948415801e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..587a167741f69a28ceab57da5e218001aeaedff4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/5ebcf382a6ee952d6c5b8b948415801e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:011a30f9413294b9251c07d987f4538c0bbce4ac839cea6bd42fb32c773b65e7
+size 3741
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2fbb7f202db6ebb96be39852b0b1e8be83cb57dd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1b880bf7bf00c6ff739fa569c746aa27fc6c1b13b42c5fac026c80dce6c3c073
+size 35377
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c2beb4babaeb4a59be08efe86174510a5e6281d3
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/9cd90f495b95ad2116ff780248c26d95_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:552c45cc2db738a688f424bddc9dbee01450c1207f85e180d2d4f3494e75329a
+size 78826
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/a69696d69cfd88b51cbd02e5288eca32_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/a69696d69cfd88b51cbd02e5288eca32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e6afcf306af5d3b2e7f83be2c6eaa1d12cb70d62
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/a69696d69cfd88b51cbd02e5288eca32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7861f137466cf39dbd236fc7655f29a61e29169758a8c4360126c863940a1381
+size 5687
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..af18d54e92048128fe5f035ccfa183fc92b72ba7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ceffd5a60edc482d87a05e9884c0a644ea8dbd48f1676ac4780c0d916f4fa261
+size 21869
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..09aff7babb8a617429bfcb44e37894a2da570516
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:098832d6727469cb58a2e3b064cc0200cad76bd29eeb0d16ccda4383de326e52
+size 85983
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/e10773081adcaeab632f9dd4c8931cd5_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/e10773081adcaeab632f9dd4c8931cd5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e461e788a68c831b012364a05e7d0415ec91e0df
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/e10773081adcaeab632f9dd4c8931cd5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2520a1123c916abe8005ead89956514235d531b2511056b2bd9bc77ff10a941d
+size 5114
diff --git a/marked/Y/T-REC-Y.2303-201501-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..56f2e91c1c94887f97c5e9d904f71b679a560103
--- /dev/null
+++ b/marked/Y/T-REC-Y.2303-201501-I_PDF-E/f6e8acf9f931452d01688d311b5c0364_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:52fa7f9634ab593cc1f5326e7b12431397da847b5bfff6ae2243ba63805cae4d
+size 34541
diff --git a/marked/Y/T-REC-Y.2330-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.2330-201609-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..da865b27fe7a87dd644806f861c7c589f4e2d57f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:eca50cf182d11e2a29943125e103fd3a33e0f196dfe97d2064eb83f9b342e457
+size 57895
diff --git a/marked/Y/T-REC-Y.2330-201609-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0bca1ec93531af483c9ce3ff4e6a8bba3e9ee645
--- /dev/null
+++ b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/e6df2733626a85205c1db682e6259c46_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d722a64154bbcb8201face340cec1ff356b3925d21360093f64e73605e827244
+size 37545
diff --git a/marked/Y/T-REC-Y.2330-201609-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..ebe831b524c3776452360f531b4c444c3ab1128f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2330-201609-I_PDF-E/raw.md
@@ -0,0 +1,538 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2330
+
+(09/2016)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Next Generation Networks – Enhancements to NGN
+
+# --- **Requirements of next generation network evolution for supporting freedata service**
+
+Recommendation ITU-T Y.2330
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|-----------------|---------------|
+| CLOUD COMPUTING | Y.3000–Y.3999 |
+|-----------------|---------------|
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.2330
+
+# Requirements of next generation network evolution for supporting freedata service
+
+## Summary
+
+Recommendation ITU-T Y.2330 specifies requirements of next generation network (NGN) evolution for supporting freedata service, enabling NGN providers to offer NGN end users, in a flexible and secure way, the ability to enjoy content or services of third party providers without being charged.
+
+Several scenarios of freedata service are described in the appendices.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.2330 | 2016-09-29 | 13 | 11.1002/1000/13013 |
+
+## Keywords
+
+Accounting and charging, data identification, freedata service, next generation network, policy management.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2016
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-------------------------------------------------------------------------------------|-------------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere ..... | 1 |
+| 3.2 Terms defined in this Recommendation ..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Introduction of NGN evolution for supporting freedata service ..... | 3 |
+| 6.1 Motivation for freedata service ..... | 3 |
+| 6.2 Basic scheme of NGN evolution for freedata service support ..... | 4 |
+| 7 Requirements of NGN evolution for freedata service support ..... | 4 |
+| 7.1 Requirements of policy management ..... | 4 |
+| 7.2 Requirements of data identification..... | 5 |
+| 7.3 Requirements of accounting and charging ..... | 5 |
+| 8 Capability framework of NGN evolution for freedata service support ..... | 5 |
+| 8.1 Capability framework overview ..... | 5 |
+| 8.2 Service stratum capabilities ..... | 6 |
+| 8.3 Accounting and charging capabilities ..... | 7 |
+| 8.4 Transport stratum capabilities ..... | 7 |
+| 9 Security considerations of NGN evolution for supporting freedata service..... | 7 |
+| Appendix I – Scenarios of freedata service ..... | 8 |
+| Appendix II – Details on freedata service data policy for data identification ..... | 10 |
+| Bibliography..... | 12 |
+
+
+
+## Recommendation ITU-T Y.2330
+
+# Requirements of next generation network evolution for supporting freedata service
+
+# 1 Scope
+
+This Recommendation specifies requirements of next generation network (NGN) evolution for supporting freedata service, to enable NGN providers to offer NGN end users, in a flexible and secure way, the ability to enjoy content or services of third party providers without being charged.
+
+In particular, this Recommendation introduces the motivation and basic scheme for freedata service support in NGN evolution. It then specifies the related requirements and capabilities of NGN evolution.
+
+The appendices provide scenarios of freedata service, as well as details on freedata service data policy for data identification.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.2012] Recommendation ITU-T Y.2012 (2010), *Functional requirements and architecture of next generation networks*.
+- [ITU-T Y.2201] Recommendation ITU-T Y.2201 (2009), *Requirements and capabilities for ITU-T NGN*.
+- [ITU-T Y.2233] Recommendation ITU-T Y.2233 (2010), *Requirements and framework allowing accounting and charging capabilities in NGN*.
+- [ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1*.
+- [ITU-T Y.2702] Recommendation ITU-T Y.2702 (2008), *Authentication and authorization requirements for NGN release 1*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 accounting** [ITU-T Y.2233]: The process of collecting and analysing NGN service and NGN resource usage metrics for the purposes of capacity and trend analysis, cost allocation, auditing, billing, etc. Accounting management requires that resource consumption be measured, rated, assigned, and communicated between appropriate business entities.
+
+**3.1.2 application** [b-ITU-T Y.2013]: A software entity residing on an application server that contributes to the delivery of an end user service.
+
+**3.1.3 application provider** [ITU-T Y.2012]: A general reference to a provider that offers applications to the customers making use of the services capabilities provided by the NGN.
+
+**3.1.4 charging** [ITU-T Y.2233]: Function within the NGN network and the associated offline charging, online charging, and billing domain components whereby information related to a chargeable event is collected, formatted, transferred and evaluated in order to make it possible to determine usage for which the charged party may be billed (offline charging) or the subscriber's account balance may be debited (online charging).
+
+**3.1.5 content** [b-ITU-T H.780]: A combination of audio, still image, graphic, video, or data.
+
+**3.1.6 next generation network (NGN)** [b-ITU-T Y.2001]: A packet-based network able to provide telecommunication services and able to make use of multiple broadband, QoS-enabled transport technologies and in which service-related functions are independent from underlying transport-related technologies. It enables unfettered access for users to networks and to competing service providers and/or services of their choice. It supports generalized mobility which will allow consistent and ubiquitous provision of services to users.
+
+**3.1.7 NGN service stratum** [b-ITU-T Y.2011]: That part of the NGN which provides the user functions that transfer service-related data and the functions that control and manage service resources and network services to enable user services and applications.
+
+**3.1.8 NGN transport stratum** [b-ITU-T Y.2011]: That part of the NGN which provides the user functions that transfer data and the functions that control and manage transport resources to carry such data between terminating entities.
+
+**3.1.9 service** [b-ITU-T Y.2091]: A set of functions and facilities offered to a user by a provider.
+
+**3.1.10 service provider** [b-ITU-T X.1123]: A service provider is a business that provides service to customers over a network; it includes not only network service providers but also application service providers.
+
+**3.1.11 user** [ITU-T Y.2201]: A user includes end user [b-ITU-T Y.2091], person, subscriber, system, equipment, terminal (e.g., FAX, PC), (functional) entity, process, application, provider or corporate network.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following term:
+
+**3.2.1 freedata service:** A service offered by a network provider which gives, in a flexible and secure way, a user the ability to enjoy content or services of third party providers without being charged for the transport traffic. The third party providers are charged by the network provider for the transport traffic concerning the content or services enjoyed by the user.
+
+NOTE – In the context of this Recommendation, the NGN provider provides the freedata service to the NGN end user.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|-----------------------------------------|
+| ANI | Application Network Interface |
+| CAF | Charging and Accounting Function |
+| DPI | Deep Packet Inspection |
+| HTTP | Hypertext Transfer Protocol |
+| ID | Identifier |
+| IMEI | International Mobile Equipment Identity |
+
+| | |
+|-----|-----------------------------|
+| IP | Internet Protocol |
+| LAC | Location Area Code |
+| NGN | Next Generation Network |
+| OSI | Open System Interconnection |
+| QoS | Quality of Service |
+| SUP | Service User Profile |
+| UNI | User Network Interface |
+| URL | Uniform Resource Locator |
+
+# **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this document is to be claimed.
+
+The keywords "is prohibited from" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this document is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement need not be present to claim conformance.
+
+The keywords "is not recommended" indicate a requirement which is not recommended but which is not specifically prohibited. Thus, conformance with this specification can still be claimed even if this requirement is present.
+
+The keywords "can optionally" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# **6 Introduction of NGN evolution for supporting freedata service**
+
+## **6.1 Motivation for freedata service**
+
+With the growing deployment of smart devices and Internet services, a lot of different business models and ecosystems, with a critical role of third party providers, have sprung up in recent years. There is a trend for users to limit or reduce the cost of accessing content or services. There is also a strong will for third party providers to attract more users in more convenient ways such as reducing the cost of the users' access to their applications.
+
+Network providers, like NGN providers, wish to have a rich ecosystem of third party providers, and benefit from the transport traffic of third party provider content or services. Consequently, there is a strong will for network providers to implement network evolution solutions for support of business models where the above expectations from users and third party providers can be satisfied.
+
+In this perspective, this Recommendation addresses a relevant business deployment by studying and specifying the requirements and capabilities which need to be supported by NGN providers for the provision of the so-called "freedata service". This service allows the NGN end users the ability to enjoy content or services of third party providers without being charged for the transport traffic. The third party providers are charged by the NGN provider for the transport traffic concerning the content or services enjoyed by the NGN end users.
+
+Clause 6.2 provides the basic scheme for the support of freedata service in NGN evolution.
+
+## 6.2 Basic scheme of NGN evolution for freedata service support
+
+Figure 1 provides the basic scheme for freedata service, which shows the related business roles, provisions and cash flows.
+
+
+
+Figure 1 is a diagram illustrating the basic scheme for freedata service. It shows three business roles: NGN provider, NGN end user, and Third party provider. The diagram uses solid arrows for provisions and dashed arrows for cash flows. The NGN provider provides the freedata service to the NGN end user. The Third party provider provides content or services to the NGN end user. The NGN provider receives the freedata service data policy from the Third party provider. The NGN end user is charged for transport traffic used by the NGN end user (dashed arrow from NGN end user to NGN provider). The NGN provider is charged for transport traffic used by the NGN end user (dashed arrow from NGN provider to Third party provider). A legend indicates that dashed arrows represent cash flow and solid arrows represent provision. The diagram is labeled Y.2330(16)\_F01.
+
+Figure 1: Basic scheme for freedata service. The diagram shows three business roles: NGN provider, NGN end user, and Third party provider. NGN provider provides freedata service to NGN end user. Third party provider provides content or services to NGN end user. NGN provider receives freedata service data policy from Third party provider. NGN end user is charged for transport traffic used by NGN end user (dashed arrow from NGN end user to NGN provider). NGN provider is charged for transport traffic used by NGN end user (dashed arrow from NGN provider to Third party provider).
+
+**Figure 1 – Basic scheme for freedata service**
+
+In the basic scheme for freedata service, three business roles are identified:
+
+- 1) NGN provider: the NGN provider provides freedata service to the NGN end user enjoying the third party provider's content or services. The NGN provider receives the freedata service data policy from the third party provider in order to identify the content or services' data of the third party provider.
+- 2) Third party provider: the third party provider provides content or services to the NGN end user through NGN. The third party provider is charged for the transport traffic of the NGN end user. In order to identify its content or services' data, the third party provider provides the freedata service data policy to the NGN provider.
+- 3) NGN end user: the NGN end user enjoys third party provider content or services through NGN, without being charged for the transport traffic used.
+
+NOTE – This basic scheme representing business roles and their relationships for the freedata service support in the context of NGN evolution does not prevent its application in other network contexts.
+
+Appendix I provides relevant scenarios of freedata service involving the various business roles.
+
+# 7 Requirements of NGN evolution for freedata service support
+
+## 7.1 Requirements of policy management
+
+NGN is required to support management of freedata service data policy [ITU-T Y.2201] by creating and maintaining the policy related to freedata service data identification, and to freedata service accounting and charging.
+
+NOTE 1 – In particular, the policy may take into account the third party provider identifier, third party provider content or service information, NGN end-user information (e.g., location, terminal). Appendix II provides details concerning options for the freedata service data policy related to data identification.
+
+NOTE 2 – The management of the freedata service data policy ensures a privacy environment for each third party provider, so that all the data related to the third party provider's content or services are not leaked or modified.
+
+NOTE 3 – The policy can be available either permanently or temporarily by manual configuration or automatic setup.
+
+## 7.2 Requirements of data identification
+
+NGN is required to support freedata service data identification features according to freedata service data policy.
+
+## 7.3 Requirements of accounting and charging
+
+NGN is required to support accounting and charging features [ITU-T Y.2233] with consideration of the following aspects:
+
+- with respect to the identified freedata service data consumed by a given NGN end user, generation of accounting information and related charging information for the third party provider;
+- with respect to the data consumed by that same NGN end user which are not part of the identified freedata service data, generation of accounting information and related charging information for the NGN end user.
+
+# 8 Capability framework of NGN evolution for freedata service support
+
+## 8.1 Capability framework overview
+
+The capabilities of NGN evolution for freedata service support are based on the NGN capabilities described in [ITU-T Y.2201].
+
+Figure 2 shows an overview of the capability framework for freedata service support in the context of the NGN reference architecture [ITU-T Y.2012].
+
+
+
+The diagram illustrates the capability framework for freedata service support within the NGN reference architecture. It shows the following components and their interactions:
+
+- Third party provider**: Connected to the **Application network interface (ANI)**.
+- Application network interface (ANI)**: Acts as a bridge, connecting the **Third party provider** to the **Accounting and charging** and **Freedata service data policy management** components.
+- Accounting and charging**: A core capability within the **NGN management** block.
+- Freedata service data policy management**: A core capability within the **NGN service stratum**, which also includes **Data identification** and **Service user profile**.
+- NGN service stratum**: The layer responsible for service-specific capabilities, including data identification and service user profiles.
+- User network interface (UNI)**: Connects the **NGN service stratum** to the **NGN end user** and the **Transport** layer.
+- NGN end user**: The user interacting with the network through the UNI.
+- Transport**: A core capability within the **NGN transport stratum**.
+- NGN transport stratum**: The layer responsible for transport-specific capabilities.
+
+The diagram is labeled Y.2330(16)\_F02 at the bottom right.
+
+Figure 2: Overview of the capability framework for freedata service support. The diagram illustrates the interaction between various components in the NGN reference architecture. A 'Third party provider' is connected to the 'Application network interface (ANI)'. The 'ANI' is linked to 'Accounting and charging' and 'Freedata service data policy management'. 'Freedata service data policy management' is further connected to 'Data identification' and 'Service user profile'. 'Data identification' and 'Service user profile' are part of the 'NGN service stratum'. The 'NGN service stratum' is connected to the 'User network interface (UNI)'. The 'UNI' is linked to 'NGN end user' and 'Transport'. 'Transport' is part of the 'NGN transport stratum'. 'Accounting and charging' is part of the 'NGN management' block. The diagram is labeled 'Y.2330(16)\_F02' at the bottom right.
+
+**Figure 2 – Overview of the capability framework for freedata service support**
+
+The capabilities of NGN evolution for supporting freedata service support the requirements identified in clause 7 as follows:
+
+- freedata service data policy management capabilities support the requirements of freedata service data policy management;
+- data identification capabilities support the requirements of data identification;
+- accounting and charging capabilities support the requirements of accounting and charging.
+
+## **8.2 Service stratum capabilities**
+
+### **8.2.1 Freedata service data policy management**
+
+Freedata service data policy management requirements are aligned with the requirements of policy management identified in [ITU-T Y.2201], in particular with the following additional requirements:
+
+- managing and storing the policy related to freedata service data identification, and freedata service accounting and charging;
+- generating the mapping between NGN end-user information and data identification parameters to be used by the data identification capabilities (e.g., mapping of international mobile equipment identity (IMEI) to an NGN end-user's Internet protocol (IP) address);
+- providing the policy related to freedata service data identification to data identification capabilities;
+- providing the policy related to freedata service accounting and charging to accounting and charging capabilities.
+
+### **8.2.2 Service user profile**
+
+Service user profile (SUP) is responsible for storing NGN end-user profiles, location related data and presence status data [ITU-T Y.2012].
+
+SUP requirements of NGN evolution for freedata service support are aligned with the functional requirements of SUP in NGN [ITU-T Y.2012] with the following additional requirements:
+
+- supporting NGN end-user terminal information (e.g., IMEI for mobile terminal);
+- providing NGN end-user information according to the freedata service data policy to the freedata service data policy management capabilities.
+
+### **8.2.3 Data identification**
+
+Data identification capabilities identify data according to the freedata service data policy's data identification requirements, in support of the following aspects:
+
+- receiving and/or retrieving the policy related to freedata service identification from the freedata service data policy management capabilities;
+- providing data identification's analysis results to the accounting and charging capabilities;
+- receiving transport traffic from the transport capabilities;
+- analysing the transport traffic and extracting transport traffic information according to the policy.
+
+NOTE 1 – Deep packet inspection (DPI) [b-ITU-T Y.2770] is one of the possible technical methods for data analysis, while it is not the mandatory one.
+
+NOTE 2 – The transport traffic information includes the following aspects (details are provided in Appendix II):
+
+- traffic flow information;
+- user information;
+- combined information.
+
+NOTE 3 – When the number of third party providers involved in freedata service is high, this can imply a large amount of identification tasks which may slow down overall performance. In such deployments, the data identification capabilities may be implemented in two separate steps: at first, the identification of the transport traffic which is not subject to charge for the NGN end user based on specific policy(s), and then, for that transport traffic, the identification of the third party provider which the transport traffic belongs to and is charged for.
+
+## **8.3 Accounting and charging capabilities**
+
+Accounting and charging requirements of NGN evolution for freedata service support are aligned with the functional requirements of charging and accounting function (CAF) in NGN [ITU-T Y.2012] with the following additional requirements:
+
+- with respect to the identified freedata service data consumed by a given NGN end user, generating accounting information and related charging information for the third party provider, according to the data identification's analysis results;
+- receiving the policy related to freedata service accounting and charging from the freedata service data policy management.
+
+## **8.4 Transport stratum capabilities**
+
+The requirements of transport capabilities of NGN evolution for freedata service support are aligned with the functional requirements of access and core transport in NGN [ITU-T Y.2012], with the following additional requirements:
+
+- mirroring the transport traffic to the data identification capabilities.
+
+# **9 Security considerations of NGN evolution for supporting freedata service**
+
+The requirements of NGN evolution for freedata service support are aligned with the NGN security requirements according to [ITU-T Y.2201], [ITU-T Y.2701] and [ITU-T Y.2702].
+
+## Appendix I
+
+### Scenarios of freedata service
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The following provides relevant scenarios of, but not limited to, freedata service:
+
+- 1) Unlimited traffic of freedata service for all NGN end users
+Any NGN end user would be allowed to use applications associated with freedata service without being charged.
+Example use case: when a third party provider produces a new application and wishes to be charged for all its data on behalf of all the NGN end users, the NGN provider would charge the third party provider instead of the NGN end users for all application data.
+- 2) Unlimited traffic of freedata service for specific NGN end users
+Some NGN end users would be allowed to use applications associated with freedata service without being charged.
+Example use case: when a third party provider produces a new office application for its employees (NGN end users) and wishes to be charged for all its data on behalf of its employees, the NGN provider would collect the employees' list and charge the third party provider instead of its employees for all application data.
+- 3) Limited traffic of freedata service for specific NGN end users
+Some NGN end users would be allowed to use applications associated with freedata service without being charged for limited traffic of the freedata service.
+Example use case: when a third party provider produces a new online shopping application and wishes to be charged for 50 Mbyte of freedata service data for a selected set of its customers (NGN end users), the NGN provider would collect the customers' list and charge the third party provider instead of that selected set of customers for the cost corresponding to the 50 Mbyte of freedata service data.
+- 4) Limited traffic of freedata service for particular terminals
+Some NGN end users using particular terminals would be allowed to use applications associated with freedata service without being charged for limited traffic of the freedata service.
+Example use case: when a terminal vendor (third party provider) promotes a new kind of terminal, the first 10000 terminal pieces are bound with a particular value-added service: anyone who uses these terminal pieces would enjoy 100 Mbyte without being charged, independently of any specific application or service. The NGN provider would charge the terminal vendor for the cost corresponding to the 100 Mbyte of freedata service data for all 10000 terminal pieces.
+- 5) Unlimited traffic of freedata service for specific NGN end users at particular locations
+At particular locations, NGN end users would be allowed to use applications associated with freedata service without being charged for unlimited traffic.
+Example use case 1: an e-shopping application provider (third party provider) would be charged for unlimited traffic of its application users (NGN end users) who use its application in specific shopping centres.
+
+Example use case 2: a shopping mall (acting as sponsor of all application providers offering content or services in the mall, then virtually representing a super third party provider) would be charged for unlimited traffic of the customers located in the mall (NGN end users), independently of the specific application they use.
+
+## Appendix II
+
+### Details on freedata service data policy for data identification
+
+(This appendix does not form an integral part of this Recommendation.)
+
+In order to enable particular content or service with freedata service, and to support different scenarios such as those described in Appendix I, the following describes key information to be taken into account by the freedata service data policy for data identification:
+
+- 1) Third party provider content or service information, including one or more of the following information options:
+
+- a) Traffic flow information:
+
+According to the open system interconnection (OSI) seven layer model, all the traffic flows are provided with adequately defined information to distinguish themselves from one another. Based on the requirements of freedata service, usable information of a traffic flow includes the following:
+
+- Network layer information:
+ - Destination IP address: in a large number of freedata service, the destination IP address is used to identify the third party provider's server, which provides content or service for NGN end users, e.g., 203.0.113.108.
+ - Source IP address: for particular NGN end users, the NGN provider is able to provide freedata service by identifying the NGN end user's source IP address, e.g., 198.51.100.32.
+- Transport layer information:
+ - Port: the port information alone cannot entirely meet the demand of distinguishing particular data. The port information is frequently used in conjunction with an IP address, e.g., 203.0.113.108:6789.
+- Application layer information, including but not limited to:
+ - Uniform resource locator (URL) (hypertext transfer protocol (HTTP) [b-IETF RFC 2616]) information: as for the data transferred in the HTTP protocol, they are always equipped with a URL, indicating the location of the uniform resource. For instance, for one third party provider with domain name 'abc.com', the third party provider is able to set 'abc.com' in order to identify all services, or set 'news.abc.com' in order to cover a particular news service.
+ - User Agent (HTTP protocol [b-IETF RFC 2616]) information: the NGN end user using HTTP protocol to transfer data indicates the type of his/her terminal in the header of the 'User Agent'. A third party provider is able to use this type for data identification: e.g., any data carrying a particular 'User Agent' header is associated with the freedata service.
+
+- b) Content or service private information:
+
+All the data flows sent by a particular content or service may be labelled by the third party provider with private information. For instance, one application using HTTP protocol may carry private headers. The NGN provider regards this private information for data identification and, if the data flows carry particular labels, they would be free of charge.
+
+2) NGN end-user information, including one or more of the following information options:
+
+a) Terminal information:
+
+Terminal information is a key information to identify terminals between each other in NGN. For instance, IMEI is used for mobile terminals. In case of mobile terminal, when it is authenticated, the terminal provides the IMEI information to the NGN, and the NGN provider is able to regard this information for data identification.
+
+b) Location information:
+
+Network-based location information (e.g., cell tower identifier (cell ID) and location area code (LAC)) indicates the location of a terminal which can be regarded by the NGN for data identification. If the specific network-based location information matches given criteria, all related data flows sent by the related terminal would be free of charge.
+
+3) Combined information:
+
+The above-mentioned key information can be used separately to identify data according to specific criteria, but it may not always meet all the requirements for identification, especially in complex scenarios (e.g., the scenario number 5 described in Appendix I). So a combination of key information may also be taken into account for data identification.
+
+Examples of combined information include but are not limited to:
+
+- IP 5-tuple: for the third party provider, in order to filter particular data flows, any data matching a given IP 5-tuple, e.g., combination of destination IP address and transportation port, can be associated with freedata service. For instance, the identification filter could be '203.0.113.108:1234'.
+- IP 5-tuple + URL: any data matching a given IP 5-tuple + URL, e.g., combination of destination IP address, transportation port and URL, can be associated with freedata service. For instance, the identification filter could be '203.0.113.108:1234 + \*.xyz.com'.
+- IP 5-tuple + application layer information: any data matching a given IP 5-tuple + Application layer information, e.g., in case of HTTP protocol, combination of a particular User Agent and destination IP address, can be associated with freedata service. For instance, if users use the third party provider's browser to visit a particular web site, these data would carry the User Agent (e.g., 'FastBrowser') of the browser and their destination IP address '203.0.113.108:1234' (which refers to the server of the web site). The identification filter could be 'User Agent (FastBrowser) + 203.0.113.108:1234'.
+- Terminal information + location information: any data sent by terminals with particular terminal information at appointed locations can be associated with freedata service. For instance, in case a mobile vendor as third party provider launches a new mobile phone product (e.g., IMEI from 864587029000000 to 864587029999999) which could surf the internet for free at a particular shopping mall (e.g., where cell ID is 21102 and LAC is 0001H), the identification filter could be 'IMEI (864587029XXXXXX) + cell ID (21102) + LAC (0001H)'.
+
+NOTE – As freedata service is based on data identification policy, the information sent by NGN end users is not to be modified in NGN.
+
+The following is an example describing the consequences of such modifications. In order to accelerate data transmission, an NGN provider might deploy a non-transparent Internet cache in NGN, storing the data that NGN end users frequently require. The cache would redirect the NGN end-user requests to the cache storage. In this case, the original destination IP address of the NGN end-user requests would be changed by the redirection to the cache storage's IP address. If destination IP address is used as key information for data identification, the data redirected to the cache cannot be associated with freedata service. This mistakenly generates charging for those data.
+
+## Bibliography
+
+- [b-ITU-T H.780] Recommendation ITU-T H.780 (2012), *Digital signage: Service requirements and IPTV-based architecture*.
+- [b-ITU-T X.1123] Recommendation ITU-T X.1123 (2007), *Differentiated security service for secure mobile end-to-end data communication*.
+- [b-ITU-T Y.1910] Recommendation ITU-T Y.1910 (2008), *IPTV functional architecture*.
+- [b-ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN*.
+- [b-ITU-T Y.2011] Recommendation ITU-T Y.2011 (2004), *General principles and general reference model for Next Generation Networks*.
+- [b-ITU-T Y.2013] Recommendation ITU-T Y.2013 (2006), *Converged services framework functional requirements and architecture*.
+- [b-ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks*.
+- [b-ITU-T Y.2301] Recommendation ITU-T Y.2301 (2013), *Network intelligence capability enhancement – Requirements and capabilities*.
+- [b-ITU-T Y.2770] Recommendation ITU-T Y.2770 (2012), *Requirements for deep packet inspection in next generation networks*.
+- [b-3GPP TS 23.203] 3GPP TS 23.203 (2016), *Policy and charging control architecture*.
+- [b-IETF RFC 2616] IETF RFC 2616 (1999), *Hypertext Transfer Protocol – HTTP/1.1*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/0bf9346902e9a3bdabf05ceacc1947f5_img.jpg b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/0bf9346902e9a3bdabf05ceacc1947f5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..80118f015ac558b1832c6d2ff744ab75fc142347
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/0bf9346902e9a3bdabf05ceacc1947f5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7020a57802059fd423b624843d007d2d8cc06d737e4df238e28655560895d672
+size 37103
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..92a5b3e707ff638e62830a8384affa19776448de
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:66082644b8cfcc2f07ca992eee19ae2c1651eb4b3a32db2b2377bce34fd5e4d0
+size 62598
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c650c430a2bf16d5df76db45f3e78e6710159c2f
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f05fb77ea549775693837872d8383ae9e3b94b05f6c884a763e04448d8c8a84d
+size 65562
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9793306d55741f8125fe8ef8bd8c4ff32eeb279c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/b3c108e7145f2017957569d06ea359cb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:586df2558e8f739cc16b2821c1f8093cea1897cf7f39e6d6e309ccf5004b62fa
+size 78895
diff --git a/marked/Y/T-REC-Y.2341-201703-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..ce7f17f234bdda490fddd9b5fc7cf1349ef1d259
--- /dev/null
+++ b/marked/Y/T-REC-Y.2341-201703-I_PDF-E/raw.md
@@ -0,0 +1,603 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2341
+
+(03/2017)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Next Generation Networks – Enhancements to NGN
+
+# --- **Next generation network evolution – Requirements and capabilities for supporting authorized account messaging service**
+
+Recommendation ITU-T Y.2341
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|-----------------|---------------|
+| CLOUD COMPUTING | Y.3000–Y.3499 |
+|-----------------|---------------|
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.2341
+
+# Next generation network evolution – Requirements and capabilities for supporting authorized account messaging service
+
+## Summary
+
+Recommendation ITU-T Y.2341 specifies requirements of profile management, identification, messaging related features, open API, resource allocation and policy control, as well as capabilities support of service stratum, transport stratum and end user in next generation network (NGN) evolution for supporting authorized account messaging service.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.2341 | 2017-03-29 | 13 | 11.1002/1000/13250 |
+
+## Keywords
+
+Authorized account messaging service, IP multimedia subsystem, IMS, next generation network, NGN.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2017
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|----------------------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | Introduction of NGN evolution for supporting authorized account messaging service..... | 3 |
+| 7 | Requirements of NGN evolution for authorized account messaging service support.. | 4 |
+| | 7.1 Requirements of profile management ..... | 4 |
+| | 7.2 Requirements of identification ..... | 4 |
+| | 7.3 Requirements of messaging related features ..... | 4 |
+| | 7.4 Requirements of open API ..... | 5 |
+| | 7.5 Requirements of resource allocation and policy control ..... | 5 |
+| 8 | Capabilities of NGN evolution for authorized account messaging service support..... | 5 |
+| | 8.1 Capability framework overview ..... | 5 |
+| | 8.2 Service stratum ..... | 6 |
+| | 8.3 Transport stratum..... | 7 |
+| | 8.4 End user ..... | 7 |
+| 9 | Security considerations of NGN evolution for supporting authorized account messaging service ..... | 7 |
+| | Appendix I – Scenarios of authorized account messaging service ..... | 8 |
+| | I.1 Subscribe and notify scenario..... | 8 |
+| | I.2 Interactive application scenario ..... | 9 |
+| | Bibliography..... | 11 |
+
+
+
+# Recommendation ITU-T Y.2341
+
+# Next generation network evolution – Requirements and capabilities for supporting authorized account messaging service
+
+# 1 Scope
+
+This Recommendation specifies requirements and capabilities of next generation network (NGN) evolution for supporting authorized account messaging service, in order to enable a NGN end user to subscribe a profile of the entity (third-party provider) for accessing the information via messaging exchange.
+
+This Recommendation introduces a basic scheme and business roles for authorized account messaging service support in NGN evolution, and it also specifies the requirements and the capabilities of authorized account messaging service in NGN evolution.
+
+Relevant scenarios for authorized account messaging service are provided in Appendix I.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.2012] | Recommendation ITU-T Y.2012 (2010), Functional requirements and architecture of next generation networks . |
+| [ITU-T Y.2021] | Recommendation ITU-T Y.2021 (2006), IMS for Next Generation Networks . |
+| [ITU-T Y.2111] | Recommendation ITU-T Y.2111 (2011), Resource and admission control functions in next generation networks . |
+| [ITU-T Y.2201] | Recommendation ITU-T Y.2201 (2006), Functional requirements and architecture of the NGN release 1 . |
+| [ITU-T Y.2234] | Recommendation ITU-T Y.2234 (2008), Open service environment capabilities for NGN . |
+| [ITU-T Y.2240] | Recommendation ITU-T Y.2240 (2011), Requirements and capabilities for next generation network service integration and delivery environment . |
+| [ITU-T Y.2701] | Recommendation ITU-T Y.2701 (2007), Security requirements for NGN release 1 . |
+| [ITU-T Y.2702] | Recommendation ITU-T Y.2702 (2008), Authentication and authorization requirements for NGN release 1 . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 application** [b-ITU-T Y.2013]: A software entity residing on an application server that contributes to the delivery of an end user service.
+
+**3.1.2 application network interface (ANI)** [ITU-T Y.2012]: Interface which provides a channel for interactions and exchanges between applications and NGN elements. The ANI offers capabilities and resources needed for the realization of applications.
+
+**3.1.3 application programming interface (API)** [b-ITU-T I.312]: An API provides a set of interfaces from an application environment to an execution environment. The execution environment provides services to the application environment.
+
+**3.1.4 next generation network (NGN)** [b-ITU-T Y.2001]: A packet-based network able to provide telecommunication services and able to make use of multiple broadband, QoS-enabled transport technologies and in which service-related functions are independent from underlying transport-related technologies. It enables unfettered access for users to networks and to competing service providers and/or services of their choice. It supports generalized mobility which will allow consistent and ubiquitous provision of services to users.
+
+**3.1.5 NGN service stratum** [b-ITU-T Y.2011]: That part of the NGN which provides the user functions that transfer service-related data and the functions that control and manage service resources and network services to enable user services and applications.
+
+**3.1.6 NGN transport stratum** [b-ITU-T Y.2011]: That part of the NGN which provides the user functions that transfer data and the functions that control and manage transport resources to carry such data between terminating entities.
+
+**3.1.7 open service environment capabilities** [ITU-T Y.2234]: Capabilities provided by an open service environment to enable enhanced and flexible service creation and provisioning based on the use of standards interfaces.
+
+**3.1.8 service** [b-ITU-T Y.2091]: A set of functions and facilities offered to a user by a provider.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 authorized account:** A profile of the entity which a NGN end user can subscribe for accessing the information via messaging exchange.
+
+NOTE 1 – "authorized" means the account is sanctioned and recognized by the service provider (third-party provider) and it is always available to be accessed.
+
+NOTE 2 – The profile is a numeric string which includes the identity of the entity and the service information of the entity.
+
+**3.2.2 authorized account messaging service:** A messaging service through which third-party provider can register to an authorized account and interact with the account subscribers via messaging exchange.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|--------------------------------------|
+| AAMS | Authorized Account Messaging Service |
+| ANI | Application Network Interface |
+| API | Application Programming Interface |
+| IMS | IP Multimedia Subsystem |
+| NGN | Next Generation Network |
+| OSE | Open Service Environment |
+| QoS | Quality of Service |
+
+| | |
+|------|-----------------------------------------|
+| RACF | Resource and Admission Control Function |
+| SUP | Service User Profile |
+| UE | User Equipment |
+| UNI | User Network Interface |
+| UTF | Unicode Transformation Format |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The keywords "is prohibited from" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement need not be present to claim conformance.
+
+The keywords "is not recommended" indicate a requirement which is not recommended but which is not specifically prohibited. Thus, conformance with this specification can still be claimed even if this requirement is present.
+
+The keywords "can optionally" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# 6 Introduction of NGN evolution for supporting authorized account messaging service
+
+Authorized account messaging service is a messaging service through which the authorized account owner of the service (third-party provider) can register to an authorized account and interact with the authorized account subscribers (NGN end user) via messaging exchange (provided by the NGN provider). The content of these messages can vary, including text, image, video, audio, location information and other types of information.
+
+Figure 1 provides the basic scheme for authorized account messaging service, which shows the related business roles and interactions among them.
+
+
+
+```
+
+graph LR
+ NGN_end_user[NGN end user]
+ NGN_provider[NGN provider]
+ Third_party_provider[Third party provider]
+
+ NGN_end_user -- "Subscribe to the authorized account" --> Third_party_provider
+ Third_party_provider -- "Register to an authorized account" --> NGN_provider
+ NGN_provider -- "NGN end user and third party provider interact by the messaging service provided by NGN provider" --> NGN_end_user
+
+```
+
+Y.2341(17)\_F01
+
+Figure 1: Basic scheme for authorized account messaging service. The diagram shows three entities: NGN end user (light blue box), NGN provider (purple box), and Third party provider (light blue box). Interactions are as follows: 1. NGN end user to Third party provider: 'Subscribe to the authorized account'. 2. Third party provider to NGN provider: 'Register to an authorized account'. 3. NGN provider to NGN end user: 'NGN end user and third party provider interact by the messaging service provided by NGN provider'.
+
+**Figure 1 – Basic scheme for authorized account messaging service**
+
+In the basic scheme for authorized account messaging service, three business roles are identified:
+
+- NGN provider: the NGN provider provides the messaging service, which realizes the connection between third-party provider (authorized account owner) and NGN end user (authorized account subscriber). The NGN provider can provide a convenient solution for message exchange;
+- Third-party provider: the third-party provider is the entity that wants to publish information or provide interactive applications to subscribers via the messaging service. An authorized account can be applied to the NGN provider by individuals or enterprises, but always needs to be registered by the NGN provider before the applicant is recognized as third-party provider. In addition, the authorized account needs to be a formal and stable source of information from the perspective of the NGN provider;
+- NGN end user: the NGN end user is the entity which is interested in the information or applications provided by the third-party provider, and subscribes to the authorized account in order to access the information or applications.
+
+# **7 Requirements of NGN evolution for authorized account messaging service support**
+
+The specific requirements for authorized account messaging service support identified in this clause are new or extended requirements to those already supported by existing NGN specifications. The requirements which are already supported by existing NGN specifications are outside the scope of this Recommendation.
+
+## **7.1 Requirements of profile management**
+
+NGN is required to support management of the third-party provider's authorized account profiles.
+
+NOTE – These profiles may include the following items: a third-party provider's authorized account, nickname, real name, description, type ( identifying if the third-party provider is a person or an enterprise), message type (of the messages sent by the third-party provider); the availability of a menu for the authorized account, the authorized account status (indicating whether the authorized account status is active or suspended or has been cancelled), other information of the third-party provider such as telephone number, email, zip code, address, field, logo, two-dimension code, etc.
+
+## **7.2 Requirements of identification**
+
+NGN is required to support identification of the authorized accounts.
+
+NGN is required to support identification of the traffic related to the authorized account messaging service.
+
+## **7.3 Requirements of messaging related features**
+
+NGN is required to support authorized account messaging related features with consideration of the following aspects:
+
+- exchange of the authorized account messages;
+NOTE 1 – An authorized account message can include text, image, audio, video, location, v-card and structured information. The structured information can include, for example, multiple media formats suitable for sending articles, news and other advertisement information.
+- NGN end-user's searching, subscribing or unsubscribing an authorized account;
+- negotiation of the message encoding mode (e.g., UTF-8, Base64) between NGN provider and NGN end-user;
+- policy and traffic control in the service level when delivering authorized account messages.
+
+NOTE 2 – Policy and traffic control can allow, for example, setting different messaging transmission rates and delivery time requirements concerning NGN delivery of authorized account messages to authorized account subscribers.
+
+## 7.4 Requirements of open API
+
+NGN is required to provide single sign-on open API to third-party providers.
+
+NOTE – A third-party provider calls the single sign-on open API to enable its subscribers login its webpage implicitly when accessing the authorized account messaging service.
+
+## 7.5 Requirements of resource allocation and policy control
+
+NGN is required to support resource allocation and policy control for large scale messaging. This includes, as an example, the setting of different messaging transmission rates and delivery time requirements concerning NGN delivery of authorized account messages to authorized account subscribers.
+
+NOTE – The number of subscribers of an authorized account may be very large. This is especially the case when there may be many authorized accounts and each authorized account has many subscribers, and a large number of messages may be sent at the same time.
+
+# 8 Capabilities of NGN evolution for authorized account messaging service support
+
+## 8.1 Capability framework overview
+
+The capabilities of NGN evolution for authorized account messaging service support are based on the NGN capabilities described in [ITU-T Y.2201]. Only new or extended capabilities for authorized account messaging service support are identified in this capability framework.
+
+Figure 2 shows an overview of the capability framework for authorized account messaging service support in the context of the NGN reference architecture [ITU-T Y.2012].
+
+
+
+The diagram illustrates the capability framework for authorized account messaging service support within the NGN reference architecture. It is structured into three main layers: the Application network interface (ANI), the NGN service stratum, and the NGN transport stratum. The Third party provider interacts with the ANI. The NGN service stratum contains several capability blocks: AAMS management capabilities (indicated by a dashed border), Open service environment capabilities, Service user profiles capabilities, and IMS based NGN capabilities. These are all supported by Application support functions and service support functions. The NGN transport stratum contains Transport capabilities. The User network interface (UNI) connects the NGN service stratum to the NGN transport stratum. End user capabilities are connected to the UNI.
+
+Figure 2: Overview of the capability framework for authorized account messaging service support in the context of the NGN reference architecture. The diagram shows a layered architecture. At the top is the 'Third party provider' connected to the 'Application network interface (ANI)'. Below this is the 'NGN service stratum' which contains 'AAMS management capabilities' (dashed box), 'Open service environment capabilities' (solid box), 'Service user profiles capabilities' (solid box), and 'IMS based NGN capabilities' (solid box). These are all connected to 'Application support functions and service support functions'. Below the service stratum is the 'NGN transport stratum' containing 'Transport capabilities'. The 'User network interface (UNI)' connects the service stratum to the transport stratum. Finally, 'End user capabilities' are connected to the UNI.
+
+**Figure 2 – Overview of the capability framework for authorized account messaging service support in the context of the NGN reference architecture**
+
+The capabilities of NGN evolution for supporting authorized account messaging service satisfy the requirements identified in clause 7 as follows:
+
+- the authorized account messaging service management capabilities (AAMS management capabilities) and end user capabilities support the requirements of messaging related features (seen in clause 7.3);
+- service user profile (SUP) capabilities support the requirements of profile management (seen in clause 7.1);
+- open service environment (OSE) capabilities support the requirements of open API (seen in clause 7.4);
+- IP multimedia subsystem (IMS) based NGN capabilities support the requirements of identification (seen in clause 7.2);
+- transport capabilities support the requirements of resource allocation and policy control (seen in clause 7.5).
+
+Clauses 8.2 to 8.4 provide details on the capabilities of NGN evolution for support of authorized account messaging service.
+
+## **8.2 Service stratum**
+
+#### **8.2.1 Service user profile capabilities**
+
+Service user profile capabilities are responsible for managing third-party providers' profiles.
+
+SUP capabilities of NGN evolution for authorized account messaging service support are aligned with the functional requirements of SUP in NGN [ITU-T Y.2012] with the following additional requirements:
+
+- support of creation and maintenance of the third-party providers' profiles;
+- support of providing third-party providers' profiles to the AAMS management capabilities.
+
+### **8.2.2 IMS based NGN capabilities**
+
+IMS-based NGN capabilities for the authorized account messaging service support are aligned with the requirements of IMS for next generation networks [ITU-T Y.2021], with the following additional requirements:
+
+- support of identification of the authorized accounts;
+- support of identification of the traffic related to the authorized account messaging service;
+- support of providing message routing between the AAMS management capabilities and end user capabilities.
+
+### **8.2.3 AAMS management capabilities**
+
+AAMS management capabilities, located in application support functions and service support functions, are responsible for dealing with the authorized account messaging service related functions.
+
+AAMS management capabilities for the authorized account messaging service are aligned with the requirements of application support and service support in NGN [ITU-T Y.2012], with the following additional requirements:
+
+- support of providing authorized account message exchange function between third-party providers and NGN end-user;
+- support of NGN end-user's authorized account searching, subscribing or unsubscribing;
+- support of negotiating message encoding mode with NGN end-user;
+
+- support of policy and traffic control in the service level when delivering authorized account messages.
+
+#### **8.2.4 Open service environment capabilities**
+
+Open service environment (OSE) capabilities are responsible for providing open APIs to third-party providers.
+
+Open service environment capabilities of NGN evolution for authorized account messaging service support are aligned with the requirements of openness identified in NGN [ITU-T Y.2234] [ITU-T Y.2240] with the additional support of single sign-on open API to third-party providers.
+
+NOTE – An authorized account calls the single sign-on open API to obtain the subscriber's identity information when one of its subscribers requires logging on the authorized account's webpage.
+
+## **8.3 Transport stratum**
+
+Transport capabilities support the provision of a channel for the exchange of authorized account messages via the interaction with the IMS-based NGN capabilities.
+
+Transport capabilities for the authorized account messaging service support the functional requirements of resource and admission control functions (RACF) [ITU-T Y.2111], with the additional support of transport resource allocation and management of quality of service (QoS) policies with respect to:
+
+- intelligent assignment and adjustment of bandwidth and QoS level for the exchange of authorized account messages according to requirements from both NGN provider and third-party provider.
+
+## **8.4 End user**
+
+End user capabilities for the authorized account messaging service are aligned with the end user functions requirements in [ITU-T Y.2012], with the following additional requirements:
+
+- support of exchanging authorized account messages with AAMS management capabilities through the user network interface (UNI);
+- support of negotiating message encoding mode with AAMS management capabilities;
+- support of NGN end user's authorized account searching, subscribing or unsubscribing through the user network interface.
+
+# **9 Security considerations of NGN evolution for supporting authorized account messaging service**
+
+The requirements of NGN evolution for authorized account messaging service support are aligned with the NGN security requirements according to [ITU-T Y.2201], [ITU-T Y.2701] and [ITU-T Y.2702].
+
+# Appendix I
+
+## Scenarios of authorized account messaging service
+
+(This appendix does not form an integral part of this Recommendation.)
+
+### I.1 Subscribe and notify scenario
+
+Figure I.1 shows the message interaction between the capabilities in the various subscribe and notify scenarios.
+
+
+
+```
+sequenceDiagram
+ participant NGN_end_user as NGN end user
+ participant NGN_provider as NGN provider
+ participant Third_party_provider as Third party provider
+
+ Note over NGN_provider: •• → I. 1. 1
+ Third_party_provider->>NGN_provider: Apply an authorized account
+ NGN_provider->>Third_party_provider: Application result
+
+ Note over NGN_end_user: •• → I. 1. 2
+ NGN_end_user->>NGN_provider: Search an authorized account
+ NGN_provider-->>NGN_end_user: Search results
+
+ Note over NGN_end_user: •• → I. 1. 3
+ NGN_end_user->>NGN_provider: Subscribe an authorized account
+ NGN_provider-->>NGN_end_user: Subscription result
+ NGN_provider->>Third_party_provider: Subscription notification
+
+ Note over NGN_end_user: •• → I. 1. 4
+ NGN_end_user->>NGN_provider: Cancel subscription of an authorized account
+ NGN_provider-->>NGN_end_user: Cancel subscription result
+ NGN_provider->>Third_party_provider: Cancel subscription notification
+
+ Note over NGN_provider: •• → I. 1. 5
+ Third_party_provider->>NGN_provider: Cancel an authorized account
+ NGN_provider->>Third_party_provider: Cancellation result
+```
+
+Y.2341(17)\_FI.1
+
+Sequence diagram showing the message interaction between NGN end user, NGN provider, and Third party provider for the subscribe and notify scenario.
+
+**Figure I.1 – The subscribe and notify scenario of the authorized account messaging service**
+
+#### I.1.1 Apply an authorized account
+
+A third-party provider applies an authorized account from the NGN provider. Then he/she is permitted to send messages to the NGN end users who have subscribed to this authorized account.
+
+#### I.1.2 Search an authorized account
+
+A NGN end user searches an authorized account on his/her user equipment (UE) according to the key words of the authorized account ID.
+
+The user clicks an item in the searching list to access the detailed information of this authorized account.
+
+#### I.1.3 Subscribe an authorized account
+
+A NGN end user subscribes an authorized account by clicking the subscription button in the authorized account's detailed information at the user interface. After successful subscription, the NGN end user can interact with this authorized account.
+
+A NGN end user can also scan an authorized account's two-dimension code to subscribe the authorized account.
+
+#### I.1.4 Cancel subscription of an authorized account
+
+A NGN end user cancels subscription of an authorized account. Then he/she will not receive the authorized account's message any more.
+
+#### I.1.5 Cancel an authorized account
+
+A third-party provider applies to cancel his/her authorized account. The final service charging is settled before the authorized account is cancelled.
+
+### I.2 Interactive application scenario
+
+Figure I.2 shows the message interaction between the various capabilities in the interactive application scenario.
+
+
+
+```
+sequenceDiagram
+ participant NGN_end_user as NGN end user
+ participant NGN_provider as NGN provider
+ participant Third_party_provider as Third party provider
+ participant Another_NGN_end_user as Another NGN end user
+
+ NGN_provider->>Third_party_provider: Set menus
+ Third_party_provider-->>NGN_provider: Setting operation result
+ NGN_provider->>NGN_end_user: Update menus
+ Third_party_provider->>NGN_provider: Send an authorized account message
+ NGN_provider->>NGN_end_user: Send an authorized account message
+ NGN_end_user->>NGN_provider: Send a message to an authorized account
+ NGN_provider->>Third_party_provider: Send a message to an authorized account
+ NGN_end_user->>Another_NGN_end_user: Forward an authorized account message
+```
+
+Y.2341(17)\_FI.2
+
+Sequence diagram showing the interactive application scenario of the authorized account messaging service. The diagram involves four participants: NGN end user, NGN provider, Third party provider, and Another NGN end user. The sequence of messages is as follows: 1. NGN provider sends 'Set menus' to Third party provider. 2. Third party provider sends 'Setting operation result' to NGN provider. 3. NGN provider sends 'Update menus' to NGN end user. 4. Third party provider sends 'Send an authorized account message' to NGN provider. 5. NGN provider sends 'Send an authorized account message' to NGN end user. 6. NGN end user sends 'Send a message to an authorized account' to NGN provider. 7. NGN provider sends 'Send a message to an authorized account' to Third party provider. 8. NGN end user sends 'Forward an authorized account message' to Another NGN end user. Blue arrows with text like '•• → I. 2. 1' indicate specific steps in the scenario.
+
+**Figure I.2 – The interactive application scenario of the authorized account messaging service**
+
+#### I.2.1 Authorized account menu setting
+
+A third-party provider sets some menu items. The menu is displayed on the chat interface of its subscribers' UE. A NGN end user interacts with the authorized account through clicking the menu items.
+
+The menu may have two levels. For example, the primary menu has three items and each of the primary menu items has five sub-menu items. Each sub-menu item executes the following three actions:
+
+- sending a message: A third-party provider sets the menu item's corresponding content as the content of a message sent to the authorized account. When a NGN end user clicks the menu item, a message or short message with this content will be sent to the authorized account;
+- accessing a web page: A third-party provider sets the menu item's corresponding content as access web address. When an authorized account subscriber clicks the menu item, the web page corresponding to that web address will be opened in the authorized account application;
+- invoking a UE's local API: A third-party provider sets the menu item's corresponding action as invoking a UE's local API. When an authorized account subscriber clicks the menu item, a UE's local API will be invoked.
+
+#### I.2.2 Authorized account message editing
+
+A third-party provider edits messages which can include text, image, audio, video, location, emoticon and structured information.
+
+The structured information can include several multimedia items. For example, each item could include the title, main text, link address of multimedia's thumbnail and link address of the whole message body.
+
+#### **1.2.3 Authorized account message sending**
+
+A third-party provider sends the message that he/she has edited to his subscribers. All subscribers or a particular subscriber group can be selected as the receivers.
+
+A third-party provider can set a welcome message sent to the new subscribers automatically. The welcome message can include text, image, video, audio, and structured information.
+
+A third-party provider can set a reply message sent in reply to his/her subscribers' messages automatically.
+
+#### **1.2.4 End user message sending**
+
+A NGN end user sends a message to an authorized account which he/she has subscribed. The message could be text, image, video, audio, location, emoticon, etc.
+
+If a NGN end user sends a message to an authorized account that has cancelled the authorized account service, he/she will receive a notification message.
+
+A NGN end user can check the exchanged messages of an authorized account.
+
+#### **1.2.5 End user message forwarding**
+
+A NGN end user can forward the free messages received from the authorized account to other NGN end users. Charged messages cannot be forwarded.
+
+## Bibliography
+
+- [b-ITU-T I.312] Recommendation ITU-T I.312/Q.1201 (1992), *Principles of intelligent network architecture*.
+- [b-ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN*.
+- [b-ITU-T Y.2011] Recommendation ITU-T Y.2011 (2004), *General principles and general reference model for Next Generation Networks*.
+- [b-ITU-T Y.2013] Recommendation ITU-T Y.2013 (2006), *Converged services framework functional requirements and architecture*.
+- [b-ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks*.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2500-202508-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.2500-202508-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.2500-202508-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.2503-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.2503-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..86f9e0c355ba2685d9d7e9463a6a2f3fe6973024
--- /dev/null
+++ b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f6c2b88ed39ff9082abd836099da5148fc1188f1b6f738000cede7338b104b55
+size 84409
diff --git a/marked/Y/T-REC-Y.2503-202512-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b775adf5bb58a2f71df14abf36d125142e5ba198
--- /dev/null
+++ b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0a7bfdbae58a8869973f5c5e1301f9ce110b1dd9da9c5b266fc16a57f076998a
+size 71489
diff --git a/marked/Y/T-REC-Y.2503-202512-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a4839a5c3e281f779c75b38bcd870ea538f797f9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2503-202512-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fa10b9e8244a1a7831f4e354f42fbec117c01f19d980f7d5b0a6d6aa7cf33c8e
+size 73507
diff --git a/marked/Y/T-REC-Y.2617-201606-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.2617-201606-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2281a53e0a37b4505d14f3adfb626cd6701de1dd
--- /dev/null
+++ b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dac6dfc2232d7f190dc953e15338b003e94f01e8f38190a4fa0d4a7fa455343a
+size 43944
diff --git a/marked/Y/T-REC-Y.2617-201606-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6551849885c7fef639164a68dc4117ad3deb681c
--- /dev/null
+++ b/marked/Y/T-REC-Y.2617-201606-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a8e3ae14dd302e797b8e47d6af27d17cd6d6edb0182762df0893571b16564d94
+size 32191
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94d45ee0d7450a0c276bffad33306ce1ec96de62
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c981deef08fa0ff69264e0a06c61f5dd291a362fb37303b3216e33a0ba5040e9
+size 5841
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9a2ba2c727cc348b8632eeb34449545e09c5b140
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f28e6464c9c443fbfb72a305d9ce31a6de2f8eee7bc023c596f1ceb3312dc587
+size 111531
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d22d73e1e9ae1e5d5f049d25cd02929ffc4062e6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1638f91bcedf8bf47c9922ce69ddbab73c1db447f0943250627face80d30be38
+size 84626
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4a6f206e8c0e350b81dcc3bbb03adf0e70c2ea7b
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4720df23907f6d6304ce363711c77a29acd2da5928a7bade23df1b039ff1e455
+size 16238
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ccfc7b5e3fa95b69d4ea16e1c3a0f6cd79adffea
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ad2d3aae12a714f42fe30c84570bf1a87b21fc13cfd436d47d6c0a746bd7b218
+size 72816
diff --git a/marked/Y/T-REC-Y.2623-202104-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..cd947b06dd45eee94138a4b90b687f4845c5b881
--- /dev/null
+++ b/marked/Y/T-REC-Y.2623-202104-I_PDF-E/raw.md
@@ -0,0 +1,526 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2623
+
+(04/2021)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Next Generation Networks – Packet-based Networks
+
+# --- **Requirements and framework of industrial Internet networking based on future packet based network evolution**
+
+Recommendation ITU-T Y.2623
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+# GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3599 |
+| BIG DATA | Y.3600–Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800–Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | |
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.2623
+
+# Requirements and framework of industrial Internet networking based on future packet based network evolution
+
+## Summary
+
+Recommendation ITU-T Y.2623 provides definitions and requirements of industrial Internet networking in support of customized, collaborative, service-oriented and intelligent production/services. It also describes a framework of industrial Internet networking for understanding significant relationships among the entities of factory internal network and factory external network.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.2623 | 2021-04-29 | 13 | 11.1002/1000/14612 |
+
+## Keywords
+
+FPBN, industrial internet networking, requirement and framework, time-sensitive networking.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2021
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|--------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Introduction ..... | 3 |
+| 7 Requirements on industrial Internet networking ..... | 4 |
+| 7.1 General requirements..... | 4 |
+| 7.2 Requirements of factory internal networking..... | 6 |
+| 7.3 Requirements of factory external networking..... | 7 |
+| 8 Framework for Industrial Internet networking ..... | 7 |
+| 8.1 Network interconnection ..... | 8 |
+| 8.2 Data communication..... | 10 |
+| 9 Security considerations..... | 11 |
+| Bibliography..... | 12 |
+
+
+
+# Recommendation ITU-T Y.2623
+
+# Requirements and framework of industrial Internet networking based on future packet based network evolution
+
+# 1 Scope
+
+This Recommendation provides definitions and requirements of industrial Internet networking in support of customized, collaborative, service-oriented and intelligent production/services. It also describes a framework of industrial Internet networking for understanding significant relationships among the entities of factory internal network and factory external network.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T G.805] Recommendation ITU-T G.805 (2000), *Generic functional architecture of transport networks*.
+- [ITU-T G.809] Recommendation ITU-T G.809 (2003), *Functional architecture of connectionless layer networks*.
+- [ITU-T X.200] Recommendation ITU-T X.200 (1994) | ISO/IEC 7498-1:1994, *Information technology – Open Systems Interconnection – Basic Reference Model: The basic model*.
+- [ITU-T Y.2611] Recommendation ITU-T Y.2611 (2006), *High-level architecture of future packet-based networks*.
+- [ITU-T Y.2612] Recommendation ITU-T Y.2612 (2009), *Generic requirements and framework of addressing, routing and forwarding in future packet-based networks*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+- 3.1.1 availability** [ITU-T Y.2611]: A measure of the capability of a given entity (for example, a layer network, connection, flow, etc.) to maintain connectivity with the associated performance criteria that have been guaranteed by the entity.
+- 3.1.2 delay** [b-ITU-T G.1050]: The time required for a packet to traverse the network or a segment of the network (see latency).
+- 3.1.3 Internet** [b-ITU-T Y.101]: A collection of interconnected networks using the Internet Protocol which allows them to function as a single, large virtual network.
+- 3.1.4 jitter** [b-ITU-T G.1050]: Variation in packet delay.
+- 3.1.5 latency** [b-ITU-T G.1050]: An expression of how much time it takes for a packet of data to get from one designated point to another (see delay).
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 industrial Internet:** A kind of industrial application ecology, characterized by convergence of the Internet and the new generation information and communication technologies (ICTs) with industrial systems, which serves as the key comprehensive information infrastructure for industrial intelligent development.
+
+**3.2.2 intelligent manufacture:** A general term for advanced manufacturing processes, systems and models that have functions of self-sensing, self-decision-making and self-implementation based on the next generation information technologies such as Internet of things (IoT), big data and cloud computing, which goes throughout all links of manufacturing activities including design, production, management, and services.
+
+**3.2.3 factory internal network:** A network used for connection between the production factors, and between the corporate information technology (IT) management systems within a factory.
+
+**3.2.4 factory external network:** A network aiming to support various activities during the whole industrial life cycle and used to connect the upstream and downstream of an enterprise, enterprise and intelligent products, as well as enterprise and users.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|------------------------------------------|
+| cl-ps | connectionless packet switched |
+| co-ps | connection-oriented packet switched |
+| DCS | Distributed Control System |
+| DDS | Data Distribution Service |
+| ERP | Enterprise Resource Planning |
+| FCS | Field bus Control System |
+| FPBN | Future Packet Based Network |
+| HTTP | HyperText Transfer Protocol |
+| ICT | Information and Communication Technology |
+| IoT | Internet of Things |
+| IP | Internet Protocol |
+| IPv4 | Internet Protocol version 4 |
+| IPv6 | Internet Protocol Version 6 |
+| IT | Information Technology |
+| LTE | Long Term Evolution |
+| MES | Manufacturing Execution System |
+| MQTT | Message Queuing Telemetry Transport |
+| NB-IoT | Narrow Band Internet of Things |
+| OPC UA | OPC Unified Architecture |
+| OT | Operation Technology |
+| PLC | Programming Logical Controller |
+
+| | |
+|-----|---------------------------|
+| QoS | Quality of Service |
+| TSN | Time-Sensitive Networking |
+| VPN | Virtual Private Network |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+The keywords "is prohibited from" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance.
+
+The keywords "is not recommended" indicate a requirement which is not recommended but which is not specifically prohibited. Thus, conformance with this specification can still be claimed even if this requirement is present.
+
+The keywords "can optionally" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option, and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with this Recommendation.
+
+# 6 Introduction
+
+Internet brings great successes in customer-oriented businesses like media, retail, travel and finance by interconnecting people and information. Now Internet, together with emerging information and communication technologies (ICTs), are penetrating industries, such as manufacturing, logistic, energy, etc., to create smart products, smart production and smart services to support the industrial digital transformation. Under such circumstances, the industrial Internet has emerged and has been widely accepted.
+
+The foundations of industrial Internet include "networking", "data" and "security".
+
+- Networking is the important infrastructure of industrial Internet to connect equipment, production lines, industrial systems and other applications to facilitate seamless integration of industrial data;
+- Data is the core, which means to generate data-based systematic intelligence through the whole-cycle perception, collection and integrated application of the industrial data to enable flexible manufacturing, operation management optimization, collaborative production organization and business model innovation, which drives industry's intelligent development;
+- Security is the guarantee to protect networks and data in industrial Internet, including equipment security, network security, controlling security, data security, application security and comprehensive security management.
+
+Networking in industrial Internet is expected to provide heterogeneous and universal availability of communication in industrial applications. It is an integration of existing and/or emerging industrial control network, computer network, data communication and other communication technologies. A large number of emerging industrial applications have put forward more requirements on the network. The generic requirements and framework of industrial Internet networking are outlined in the following clauses which should be considered when selecting an appropriate solution.
+
+Future packet based network (FPBN) is composed of packet-based path layer networks (as defined in [ITU-T G.805] and [ITU-T G.809]) in the transport stratum, whereas high level architecture is defined in [ITU-T Y.2611] and general framework and mechanisms are defined in [ITU-T Y.2612].
+
+An FPBN is located between the service stratum and the lower part of the transport stratum (the functionality is similar to layers 2 and 3 in [ITU-T X.200]) (see Figure 6-1). An FPBN may provide co-ps and/or cl-ps transport stratum services. An FPBN may be implemented with multiple layer networks. Each layer network 'system' in an FPBN consists of a user plane, a control plane and a management plane and each of the planes within a layer network will have its own traffic forwarding component which may belong to the same layer network (if the planes are not isolated from each other) or different layer networks (if the planes are isolated from each other).
+
+
+
+Figure 6-1: Relationship between an FPBN and the transport and service strata. The diagram shows a vertical stack of three rectangular boxes. The top box is labeled 'Service stratum' to its right. The middle box is labeled 'FPBN' in its center. The bottom box is labeled 'Media-dependent layer networks' in its center. A dashed horizontal line separates the top box from the middle box. To the right of the bottom box is the label 'Transport stratum'. Below the bottom box, centered, is the text 'Y.2623(21)\_F6-1'.
+
+**Figure 6-1 – Relationship between an FPBN and the transport and service strata**
+
+# **7 Requirements on industrial Internet networking**
+
+## **7.1 General requirements**
+
+### **7.1.1 Heterogeneous connectivity**
+
+It is required to have the ability to connect the heterogeneous entities inside or outside the factories involving different technologies finally to promote interoperability of data from different systems or networks. Those heterogeneous connected entities include:
+
+- all kinds of sensing, measuring, controlling and actuating devices,
+- people, such as workers, directors, warehouse managers, sales, designers, and customers,
+- networks, such as wired networks and wireless networks,
+- systems, such as MES and ERP,
+- and cloud platforms.
+
+### **7.1.2 Extreme differentiated QoS guarantee**
+
+It is required to provide whole-process service quality guarantee to satisfy end-to-end network quality requirements of different industrial internet applications.
+
+It is required to provide different guaranteed quality of service (QoS) communication services between connected entities in different scenarios for the same enterprise and/or between different enterprises.
+
+The QoS is recommended to be supported from the most stringent requirements, for example, latency of less than 1ms for some applications in time-critical closed-loop communication scenarios, to best effort qualities.
+
+### **7.1.3 Service transparent**
+
+It is required that industrial Internet is transparent to different industrial applications and services to avoid frequent adaptation or switching across various industrial scenarios and vertical applications.
+
+It is required to support the intelligent perception of industrial service requirements and network status, to efficient adaptation between industrial service requirements and network resources.
+
+It is required to provide network service orchestration capability to support industrial users and users in other fields to make customization on network functions and protocols by open interfaces.
+
+#### **7.1.4 Trustworthy communication**
+
+To provide a trustworthy communication, it is recommended to have some abilities including
+
+- reliable data transmission,
+- strict resources management for guaranteed QoS communication so that the isolated resources would not be occupied by others,
+- in-network security mechanisms to secure data transmission.
+
+#### **7.1.5 Enhanced network virtualization**
+
+It is required to provide large-scale of isolated virtual networks to different industry enterprises and industrial applications.
+
+It is required to expose management function to customers to manage their virtual networks.
+
+#### **7.1.6 Data exchange**
+
+It is recommended to define industry data semantics and syntax to support industry data exchange.
+
+NOTE – In different industry applications, there may be different industrial data which obeys different syntax and means different semantics, so it is necessary to define the common industry data semantics and syntax, which help for data transfer among different applications and different enterprises, to increase the value of industry data.
+
+#### **7.1.7 Compatibility**
+
+It is required to be compatible with the legacy industrial systems and networks (e.g., PROFINET, EtherNet/IP, EtherCAT) in order to protect past investment and still take the future developments into consideration.
+
+#### **7.1.8 Scalability**
+
+It is required to have the ability to provide information exchange on a wider and more fine-grained scale and to be expanded vertically and horizontally to keep the growth of the industry applications.
+
+It is required to implement live update for network protocols to support the smooth integration of new network technologies into existing industrial Internet deployments.
+
+NOTE – Network technology evolution has consistently followed a cycle similar to Moore's Law with frequent turnover of products and increases in performance. In contrast, operation technology (OT) systems comprise systems with longer life cycles, on average 19 years. This difference in development speed leads to slow adoption of new network technologies into existing OT deployments. Manufacturing subsystems should therefore be decoupled from the network devices while keeping a consistent interface between them.
+
+#### **7.1.9 Flexibility**
+
+It is required to support self (re)configure dynamically to provide flexibility and dynamics in network planning and re-configuration.
+
+NOTE – To support flexible manufacturing, the network should be able to self (re)configure dynamically. Therefore, one of the design considerations is to provide flexibility and dynamics in network planning and re-configuration.
+
+#### **7.1.10 Reliability**
+
+It is required to provide means and measures to support reliable communication in harsh industrial environments.
+
+It is required to provide embedded security capability to realize endogenous security and network tractability so as to protect the security of critical applications.
+
+NOTE – Reliability and security are key requirements of industrial networks as any unexpected communication interruption and malfunction might result in work suspension, damage of equipment, or even casualty. The future industrial network must provide means and measures to support reliable communication in harsh industrial environments.
+
+## **7.2 Requirements of factory internal networking**
+
+### **7.2.1 Network convergence**
+
+It is required to be able to facilitate connectivity between different industrial network protocols, such as time-sensitive networking (TSN) and industrial Ethernet protocols defined in IEEE 802 serial specifications.
+
+It is recommended to support vertical integration and network flat by the way of the convergence of IT network, OT network and the Internet.
+
+NOTE – The traditional automation pyramid comprises a sensor level, a device level, a control level and an enterprise level. Each level adopts different network infrastructures and technologies. Field bus or industrial Ethernet are used at the sensor and the device level. Standard Ethernet is commonly used at the control level and above. Gateways are required to bridge these two networks. In industrial Internet networking, the automation pyramid will become more and more flattened. Therefore, a common network infrastructure from top to down should be applied in order to support the convergence of IT, OT and the Internet without any need of technology conversion (e.g., interface type, switching, routing).
+
+### **7.2.2 Openness and green**
+
+It is required to provide open architecture, protocols and technologies in Industrial Internet networking to support maximum interoperability and to promote wide cooperation among industrial partners.
+
+It is required to provide highly efficient power consumption mechanisms to support green communication.
+
+#### **7.2.3 Determined real-time reliable communication**
+
+It is required to provide determined real-time reliable communication for automation production, including deterministic ultralow latency transmission in the order of sub-milliseconds, very low jitter to ensure the applications' integrity and predictable system performance.
+
+#### **7.2.4 Clock synchronization**
+
+It is required to provide the function of clock synchronization in Industrial Internet networking to support time-sequence sensitive factory activities, such as cooperative assembling with multiple robots.
+
+#### **7.2.5 Mobility**
+
+It is recommended to support different levels of mobility including workshop level and factory level. Characteristics of mobility include how frequently mobility occurs, how fast the mobile object is moving and requirements on needed bandwidth and latency while mobile.
+
+#### **7.2.6 Trustworthy communication**
+
+It is required to provide certain security mechanisms to secure data transmission.
+
+It is required to provide means and measures to support the functional and process safety standards for automation systems.
+
+NOTE – A high degree of safety assurance is required for life- and mission-critical manufacturing systems to avoid unintended consequences during system operation. Industrial Internet must be capable of providing means and measures to support the functional and process safety standards for automation systems.
+
+## **7.3 Requirements of factory external networking**
+
+### **7.3.1 Heterogeneous connectivity**
+
+It is required to have the ability to connect the heterogeneous networks between factories, branches in one enterprise, or between enterprises.
+
+NOTE – It is required to support tens of billions of terminal accesses, as the number of connected industrial equipment and products will reach tens of billions.
+
+### **7.3.2 Isolated connectivity**
+
+It is required to provide isolated connectivity for different enterprises to connect their factories or branches or collaborative companies.
+
+It is required to provide different types of QoS services in one isolated connectivity for different communication requirements in one enterprise.
+
+NOTE 1 – It is required to support hundred-level application network plane. Considering the industrial site OT and IT applications as well as future business development, the network plane required by different qualities should be at the hundred-level.
+
+NOTE 2 – It is required to support the segregation of millions of users. If it is calculated based on 3~5 virtual private networks (VPNs) for each enterprise, the network's bearing capacity needs to reach the mega-level VPNs.
+
+#### **7.3.3 Flexibility**
+
+It is required to support highly efficient virtual network configuration on Internet or specific Industrial Internet public network infrastructure.
+
+It is required to support self (re)configure dynamically to provide flexibility and dynamics in network planning and re-configuration in factory external networking.
+
+#### **7.3.4 Trustworthy communication**
+
+It is required to have security mechanisms to secure data transmission in factory external network infrastructure.
+
+# **8 Framework for Industrial Internet networking**
+
+Networking in Industrial Internet is expected to provide heterogeneous and universal availability of communication in industrial applications. It closely links equipment, production lines, employees, factories, warehouses, suppliers, products and customers, ultimately to share the various data of the entire process of industrial production.
+
+Industrial Internet networking can be categorized into two layers which are network interconnection layer and data communication layer as shown in Figure 8-1. Network interconnection layer is further categorized into two parts, that is, factory internal network and factory external network. Edge computing cooperates with the factory internal network to provide convenient connectivity among industrial devices and fast intelligent response. It also cooperates with the factory external network to realize the data distribution of industrial enterprises and ensure that the data is not shipped. Data communication layer serves to provide interoperability of data and information from heterogeneous systems in order to support various industrial applications.
+
+
+
+Y.2623(21)\_F8-1
+
+Figure 8-1 – Framework of Industrial Internet networking. The diagram is divided into two main horizontal sections: 'Data communication' (top, orange background) and 'Network interconnection' (bottom, blue background). The 'Data communication' section is further divided into three layers: 'Semantic interoperability' (containing Semantic interoperability, Data dictionary, Semantic mapping and interchange, Semantic association, and Semantic fusion), 'Information model' (containing Unit information model and Combined information model), and 'Application layer communication' (containing HTTP, OPC UA, DDS, and MQTT). The 'Network interconnection' section is divided into two main parts: 'Factory internal network' (left, blue background) and 'Factory external network' (right, blue background). The 'Factory internal network' is further divided into 'OT-IT integration network' (containing Monitoring and management of equipment, products, environment, persons; Real-time control; Office application; Motion control; and Manufacturing management) and 'Physical assets'. The 'Factory external network' is further divided into 'Backbone network' (containing Common link and High performance and reliable link) and 'Physical assets'. A vertical bar labeled 'Edge computing' connects the 'OT-IT integration network' and the 'Backbone network'.
+
+**Figure 8-1 – Framework of Industrial Internet networking**
+
+## 8.1 Network interconnection
+
+### 8.1.1 Factory internal network
+
+The factory internal network is designed to connect physical assets and systems within a factory. It can be further divided into a factory OT (industrial manufacturing and control) network and factory IT network. For security reasons, the factory internal network should be separated from the factory external network by firewall.
+
+As shown in Figure 8-2, an implementing framework of factory internal networking under the industrial internet scenario consists of six major aspects.
+
+- **Factory IT network:** It mainly aims to connect office systems, mail servers, production management systems, data centers, and more via high-speed Ethernet and TCP/IP for network interconnection.
+- **Factory OT network:** It mainly aims to connect physical assets such as controllers (PLC, DCS, FCS), sensors, servos and monitoring equipment at the manufacture site, and its enabling technologies includes the industry field bus and industrial Ethernet.
+- **Edge computing:** To provide convenient connectivity among industrial devices and fast intelligent response, the industrial enterprises need to deploy edge computing close to production sites or factories. Edge computing is also a bridge between IT and OT networks.
+- **Direct network connection to smart machines and articles in process:** Smart machines, sensors, articles in process and other manufacturing site equipment and items will be able to directly connect to the IT network to realize real-time data acquisition of the manufacturing site.
+- **Ubiquitous wireless connection:** The smart machines, articles in process, sensors and transmission equipment on the manufacturing sites will be connected with various wireless technologies, such as Zigbee short-distance communication technology or Wi-Fi, LTE
+
+enhanced, NB-IoT, IMT-2020 and other wireless technologies according to equipment power consumption and transmission distances.
+
+**IT/OT integration networking:** With the development of Industrial Internet, the factory IT and OT networks will be gradually integrated into a fully-connected network. The factory internal networking is developing towards flattening, IP-based, wireless, and flexible networking.
+
+
+
+1. IT network
+2. OT network
+3. Edge computing
+4. Network connection directly reaching smart machines and WIP
+5. Ubiquitous wireless connection
+6. IT/OT integration networking
+
+Figure 8-2: Implementing framework of factory internal networking. The diagram illustrates a multi-layered industrial network architecture. At the top, five hexagonal icons represent business systems: SCM, ERP, CRM, MES, and SCADA, all connected to a central 'Industrial cloud computer (and management software)'. Below this, an 'Administrator' icon is shown. The core of the network consists of two overlapping cloud shapes: the 'IT network' (labeled 1) and the 'OT network' (labeled 2). A yellow box labeled 'Edge computing' (labeled 3) is positioned between them. A 'Supervisory device' is connected to the IT network via a 'Data acquisition' link (labeled 4). Three 'Smart machine' icons are connected to the OT network via 'Ubiquitous wireless connection' (labeled 5). These machines are shown processing 'Articles being processed', with a 'Worker' icon nearby. An 'Industrial control' system is connected to the OT network, with an 'Engineer' icon. A dashed line labeled 'IT/OT integration networking' (labeled 6) connects the top-level cloud computer to the industrial control system. A legend at the bottom clarifies the numbered labels: 1. IT network, 2. OT network, 3. Edge computing, 4. Network connection directly reaching smart machines and WIP, 5. Ubiquitous wireless connection, 6. IT/OT integration networking.
+
+**Figure 8-2 – Implementing framework of factory internal networking**
+
+### 8.1.2 Factory external network
+
+The factory external networking refers to the network that connects the upstream and downstream of industry chain, enterprise and intelligent products, enterprises, and users with the aim to support the activities in the whole industrial life cycle.
+
+
+
+1. Public Internet
+2. Virtual private network
+3. Physical private network
+
+4. Support access to industrial cloud platform and data acquisition
+5. Data distribution and data preprocessing via edge computer
+
+Y.2623(21)\_F8-3
+
+Figure 8-3: Implementing framework of factory external networking. The diagram shows a multi-layer architecture. At the top is the 'Industrial cloud platform' containing 'Design collaboration', 'Supply collaboration', 'Manufacturing collaboration', 'Service collaboration', and 'Product service'. Below this is a network layer with three components: '1 Public Internet' (blue cloud), '2 Virtual private network' (pink cloud), and '3 Physical private network' (yellow cloud). These are connected to a bottom layer of 'Factory internal network 1', 'Factory internal network 2', 'Smart product', and 'User'. A '4' in a circle is on the line connecting the cloud platform to the network layer. A '5' in a circle is on the line connecting the cloud platform to an 'Edge computing' cloud. A legend at the bottom explains the numbered components.
+
+**Figure 8-3 – Implementing framework of factory external networking**
+
+As shown in Figure 8-3, an implementing framework of factory external networking consists of five major aspects.
+
+- **Public Internet:** As the industrial internet terminals will reach tens of billions, it is imperative to deploy IPv6 in the public Internet and take into consideration the transition from IPv4 to IPv6.
+- **Virtual private network:** The interconnection between enterprises branches can be realized fast and flexibly through logical isolation technology.
+- **Physical private network:** For some businesses that have higher network quality requirements or are critical, physical private network can meet the needs of resource isolation, high reliability, high security, etc.
+- **To support access to the industrial cloud platform and data acquisition:** The factory external networking supports the enterprise's information system, manufacturing control system, data transmission from various intelligent products to the industrial cloud platform and relevant service quality guarantee.
+- **Edge computing:** Edge computing cooperates with the factory external network to realize the data distribution of industrial enterprises and ensure that the data is not shipped. Edge cloud can also implement data pre-processing and edge caching to reduce the pressure on the backhaul link and improve the data processing efficiency.
+
+Further integration of industry and external network will drive the development of customization, remote monitoring, intelligent product services and other brand-new manufacturing and service models. Therefore, the factory external networking needs to be faster in speed, better in quality, lower in latency, safer, more reliable and flexible in networking.
+
+## 8.2 Data communication
+
+The function of data communication layer is to deliver data and information between elements and systems seamlessly, in order to realize data interoperability and information integration. It provides access interfaces of multi-source heterogeneous system data to the upper applications and supports the rapid development and deployment of industrial applications.
+
+The data communication layer includes application layer communication, information model, and semantic interoperability.
+
+Using protocols such as OPC UA, MQTT, HTTP and DDS, the application layer communication realizes the establishment, maintenance, and shutdown of data transmission security channel, as well as the management of equipment, sensors, remote terminal units, servers, and other equipment nodes supporting the industrial data resource model.
+
+The information model provides complete and unified data object expression, description and operation model via unit information model and combined information model. The unit information model aims at a single object, such as a PLC and a metering unit. The object of a combined information model will be more complex. The combined information model is an information cluster formed by the combination and superposition of interrelated unit information models.
+
+The semantic interoperability realizes the discovery, collection, query, storage, interaction, as well as request, response, publication and subscription of industrial data. It includes data dictionary, semantic mapping and interchange, semantic association, and semantic fusion. The data dictionary is a collection of information used to describe data. The semantic mapping and interchange is to map and interchange industrial data with different description modes. The semantic association is to establish an association between industrial data and factory production information. The semantic fusion is a high-level application of semantic association which is to construct a knowledge graph of industrial scenarios.
+
+# **9 Security considerations**
+
+Security is the guarantee to protect networks and data in Industrial Internet. The security requirements of factory internal and external networking are described in the relevant clauses in this Recommendation and will therefore not be repeated in this clause.
+
+## Bibliography
+
+- [b-ITU-T G.1050] Recommendation ITU-T G.1050 (2016), *Network model for evaluating multimedia transmission performance over Internet Protocol*.
+- [b-ITU-T Y.101] Recommendation ITU-T Y.101 (2000), *Global Information Infrastructure terminology: Terms and definitions*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..072f073b6d42cbfa77c827c76c611f286177034a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee72ddf991b7b1d543b2694b1687804845ecb97da77cc35e98e4c7dbf5ac163d
+size 4142
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/1a85642ed2356d183ce598f2c8b3ee8b_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/1a85642ed2356d183ce598f2c8b3ee8b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..25f80c9013fcc087eaf2133db851669f1e2629e6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/1a85642ed2356d183ce598f2c8b3ee8b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7fc81bd004b0650edd2332faca7c5e75e90d5451e2079815902d0edbc82a30aa
+size 58527
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..06812bf4fdfcf620179799e1df55ffbe103958c7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/41a438d7e4adc17c3a4005e7c9500091_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:878cfb00c120a86b4379e95e8cd6127b41afb9be256586a0e76e4950a69df141
+size 50069
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4f25e9fb8b83820b829003962dda871284fce7c4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:eeb4b60900a0a7177d3774345f31f8f31f51e6fcf7fdad8c21fc6bd315f9b7cb
+size 31914
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..efbde103083d8881fd5b79681d8a6143b6d38e85
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f3d31b98fa5ab5d3d225e473cf18711db50f7b00d564ceff8eea5f1ddee7a343
+size 86416
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..befa2cf0845b97e75d657ae056fcb1c702c817ed
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e2da686e1c92770df5f74231351bce7bee14461f21e44dd840a40ed4aeb3a653
+size 55151
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b883ab540561fb57bd1ec09961fa0f0b851473f6
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b50137e767816cdac35fe8282d4e980f7c88b20bf74420f9bca3d6eea60632bc
+size 66440
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..549d705644b4dcffc1bb72a97f25ada4165bd686
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fd8e3e0f3e8417bd526735631544a0c7495d5f9a0f48e6e07ee9ede82431f63c
+size 40364
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/d48475a25698b1c0592e4cfe07138f2a_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/d48475a25698b1c0592e4cfe07138f2a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..15686240bb7741ba14c23643de0b2dbbe39970bb
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/d48475a25698b1c0592e4cfe07138f2a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:73567cea41c8f4aeaea3d14f8c197657de79f528387939e2cfea109e570f9bcb
+size 108731
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/eb03559a4d92ea9ebd63ea9be663c50a_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/eb03559a4d92ea9ebd63ea9be663c50a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cad352d39000fdef77b500d46510dfd8520b0724
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/eb03559a4d92ea9ebd63ea9be663c50a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:322fcda25206ae6c9a5f5bb662db30cc38e4b0161cf4ac24d84b5da85ddaec53
+size 66829
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..88bc4fd624e8e22b8acdccd6733ebf68d06679a4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:020ff86008745c9151cf9c21b9a80e2f4bb3045e485a4bc802f0035938db8a8a
+size 50208
diff --git a/marked/Y/T-REC-Y.2772-201604-I_PDF-E/raw.md b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..6cde1148f122af04399f16273019ff3f8a5ea1c8
--- /dev/null
+++ b/marked/Y/T-REC-Y.2772-201604-I_PDF-E/raw.md
@@ -0,0 +1,892 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.2772
+
+(04/2016)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Next Generation Networks – Security
+
+# --- **Mechanisms for the network elements with support of deep packet inspection**
+
+Recommendation ITU-T Y.2772
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|----------------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|-----------------|---------------|
+| CLOUD COMPUTING | Y.3000–Y.3999 |
+|-----------------|---------------|
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.2772
+
+# Mechanisms for the network elements with support of deep packet inspection
+
+## Summary
+
+Recommendation ITU-T Y.2772 provides mechanisms for the network elements supporting deep packet inspection (DPI), including the procedures and methods aspects of deep packet inspection (DPI) with respect to packet based networks. This Recommendation serves to assist in the understanding of DPI related methods, interfaces, protocols, procedures aspects and process aspects of DPI-related products.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.2772 | 2016-04-29 | 13 | 11.1002/1000/12709 |
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2016
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|---------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 3 |
+| 4 | Abbreviations and acronyms ..... | 3 |
+| 5 | Conventions ..... | 3 |
+| 6 | Definition of DPI mechanism..... | 4 |
+| 7 | Overview of DPI mechanisms in support of application identification ..... | 4 |
+| | 7.1 General aspect of DPI mechanisms..... | 4 |
+| | 7.2 Basic structure of a DPI node..... | 4 |
+| | 7.3 Typical network supporting DPI functions. .... | 4 |
+| | 7.4 DPI mechanism related to the DPI node ..... | 5 |
+| | 7.5 The mechanism of a network deployed with DPI nodes..... | 6 |
+| 8 | Representation methods of the DPI – Policy rule of DPI-PIB ..... | 6 |
+| | 8.1 Overview ..... | 6 |
+| | 8.2 Data and mask representation method for DPI policy rule conditions..... | 6 |
+| | 8.3 Regular expression representation method for DPI policy rule conditions.... | 6 |
+| | 8.4 Hybrid representation method for DPI policy rule conditions ..... | 7 |
+| 9 | Information flows, processing procedures and methods for a DPI entity ..... | 7 |
+| | 9.1 Overview ..... | 7 |
+| | 9.2 Interface realization ..... | 8 |
+| | 9.3 Information flow..... | 9 |
+| | 9.4 Process procedure..... | 12 |
+| | 9.5 Protection method..... | 13 |
+| | 9.6 Data synchronization method ..... | 13 |
+| 10 | Operational mechanism specification..... | 14 |
+| | 10.1 Overview ..... | 14 |
+| | 10.2 Objectives of the operation mechanism ..... | 15 |
+| | 10.3 Performance aspect or DPI nodes deployment..... | 15 |
+| | 10.4 Analysis of current networks..... | 15 |
+| | 10.5 Confirming the DPI requirement of the network ..... | 15 |
+| | 10.6 Choosing proper DPI entities or systems ..... | 16 |
+| | 10.7 Reconstructing the current network using DPI ..... | 16 |
+| | 10.8 Monitoring and managing the network with DPI..... | 16 |
+| | 10.9 Rebuilding the network with DPI based on performance monitor..... | 16 |
+
+| | Page |
+|---------------------------------------------------|-------------|
+| 11 Specification of management mechanism ..... | 16 |
+| 11.1 Overview of DPI network management ..... | 16 |
+| 11.2 Management interface ..... | 18 |
+| 11.3 Management protocol and functions ..... | 20 |
+| 12 Security consideration ..... | 20 |
+| Bibliography..... | 20 |
+
+# Recommendation ITU-T Y.2772
+
+# Mechanisms for the network elements with support of deep packet inspection
+
+# 1 Scope
+
+This Recommendation provides the implementation mechanisms for deep packet inspection (DPI) in packet based networks. The primary purpose of this Recommendation is to describe the application models, related protocols, interface, methods procedure and process of DPI that can be used to identify information flows between DPI functions and other network functions.
+
+The scope of this Recommendation includes:
+
+- definition of DPI mechanism;
+- overview of DPI mechanisms in support of application identification;
+- procedures and information flows in operational aspect;
+- procedures and information flows in management aspect, such as DPI policy management;
+- other procedures and information flows for possible DPI functional entity (FE) interfaces.
+
+The following are out of the scope of this Recommendation:
+
+- operational and management aspects that are not specific to DPI entities;
+- common network element related management functions, as already specified by the ITU-T M-series and ITU-T X-series Recommendations.
+
+Implementers and users of this Recommendation shall comply with all applicable national and regional laws, regulations and policies. The mechanism described in this Recommendation may not be applicable to international correspondence in order to ensure the secrecy and sovereign national legal requirements placed upon telecommunications providers, as well as the ITU Constitution and Convention.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.2111] | Recommendation ITU-T Y.2111 (2011), Resource and admission control functions in next generation networks . |
+| [ITU-T Y.2704] | Recommendation ITU-T Y.2704 (2010), Security mechanisms and procedures for NGN . |
+| [ITU-T Y.2770] | Recommendation ITU-T Y.2770 (2012), Requirements for deep packet inspection in next generation networks . |
+| [ITU-T Y.2771] | Recommendation ITU-T Y.2771 (2014), Framework for deep packet inspection . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 deep packet inspection (DPI)** [ITU-T Y.2770]: Analysis, according to the layered protocol architecture OSI-BRM [b-ITU-T X.200], of:
+
+- payload and/or packet properties (see list of potential properties in clause 3.2.11 of [ITU-T Y.2770] deeper than protocol layers 2, 3 or 4 (L2/L3/L4) header information, and
+- other packet properties
+
+in order to identify the application unambiguously.
+
+NOTE – The output of the DPI function, along with some extra information such as the flow information, is typically used in subsequent functions such as reporting or actions on the packet.
+
+**3.1.2 DPI analyser** [ITU-T Y.2771]: A subsequent entity in the DPI processing path (within a DPI policy enforcement function) with focus on comparison functions between the particular packet headers and payloads of preselected packet flows. The primary scope of the DPI analyser is related to the evaluation of DPI policy *conditions* against *preselected* incoming packets.
+
+NOTE – The DPI analyser may be located after a DPI scanner (see clause 3.2.5 of [ITU-T Y.2771]). The DPI analyser may provide the functionality of an intrusion detection system (IDS) analyser.
+
+**3.1.3 DPI engine** [ITU-T Y.2770]: A subcomponent and central part of the DPI functional entity which performs all packet path processing functions (e.g., packet identification and other packet processing functions in Figure 6-1 of [ITU-T Y.2770]).
+
+**3.1.4 DPI node** [ITU-T Y.2771]: A network element or device that realizes the DPI related functions. It is thus a generic term used to designate the realization of a DPI physical entity.
+
+NOTE – Functional perspective: the DPI node function (DPI-NF) comprises the DPI policy enforcement function (DPI-PEF) and the (optional) local policy decision function (L-PDF); the DPI-NF is functionally equal to the DPI functional entity.
+
+**3.1.5 DPI policy action (action in short)** [ITU-T Y.2771]: Definition of what is to be done to enforce a policy rule, when the conditions of the rule are met. Policy actions may result in the execution of one or more operations to affect and/or configure network traffic and network resources (see also [b-IETF RFC 3198]).
+
+**3.1.6 DPI policy condition (also known as DPI signature)** [ITU-T Y.2770]: A representation of the necessary state and/or prerequisites that identifies an application and define whether a policy rule's actions should be performed. The set of DPI policy conditions associated with a policy rule specifies when the policy rule is applicable (see also [b-IETF RFC 3198]).
+
+A DPI policy condition must contain application level conditions and may contain other options such as state conditions and/or flow level conditions:
+
+- 1) State condition (optional):
+ - a) network grade of service conditions (e.g., experienced congestion in packet paths); or
+ - b) network element status (e.g., local overload condition of the DPI-FE).
+- 2) Flow descriptor/flow level conditions (optional):
+ - a) packet content (header fields);
+ - b) characteristics of a packet (e.g., number of MPLS labels);
+ - c) packet treatment (e.g., output interface of the DPI-FE);
+- 3) Application descriptor/application level conditions:
+ - a) packet content (application header fields and application payload).
+
+NOTE – The condition relates to the "simple condition" in the formal descriptions of flow level conditions and application level conditions.
+
+**3.1.7 DPI scanner (also used as "DPI scan function")** [ITU-T Y.2771]: The first entity in the DPI processing path (within a DPI policy enforcement function) which provides a pre-selection (related to the subsequent DPI analyser, see clause 3.2.1 of [ITU-T Y.2771]) by checking *all* DPI policy *conditions* against *all* incoming packets.
+
+## 3.2 Terms defined in this Recommendation
+
+None.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|----------|------------------------------------------|
+| BRAS | Broadband Remote Access Server |
+| CLI | Command Line Interface |
+| CMIP | Common Management Information Protocol |
+| DPI | Deep Packet Inspection |
+| DPI-PDFE | DPI Policy Decision Functional Entity |
+| DPI-PIB | DPI Policy Information Base |
+| EMS | Element Management System |
+| GUI | Graphical User Interface |
+| IP | Internet Protocol |
+| IPFIX | IP Flow Information Export |
+| LAN | Local Area Network |
+| L-PDF | Local PDF |
+| NMS | Network Management System |
+| OAM | Operation, Administration and Management |
+| PDF | Policy Decision Function |
+| PIB | Policy Information Base |
+| SNMP | Simple Network Management Protocol |
+| SR | Service Router |
+| TCAM | Ternary Content-Addressable Memory |
+| TCP | Transmission Control Protocol |
+| UDP | User Datagram Protocol |
+| VLAN | Virtual Local Area Network |
+
+# 5 Conventions
+
+None.
+
+# **6 Definition of DPI mechanism**
+
+In this Recommendation, the term "mechanism" is considered to include the means, methods, processes and procedures to realize some function or meet some requirement. With this consideration in mind, a DPI mechanism can be described as follows:
+
+- concrete process that can be used to carry out the functions and capabilities defined in [ITU-T Y.2771] and requirements defined in [ITU-T Y.2770];
+- detailed procedure that can be adopted to realize the functions and capabilities defined in [ITU-T Y.2771] and requirements defined in [ITU-T Y.2770];
+- proper methods that can be made use of to achieve the functions and capabilities defined in [ITU-T Y.2771] and requirements defined in [ITU-T Y.2770];
+- specialized tools or means that can be assisted by to achieve the functions and capabilities defined in [ITU-T Y.2771] and requirements defined in [ITU-T Y.2770].
+
+# **7 Overview of DPI mechanisms in support of application identification**
+
+## **7.1 General aspect of DPI mechanisms**
+
+The DPI mechanisms include two main aspects:
+
+- DPI mechanisms relative to the DPI node;
+- DPI mechanisms corresponding to the network supporting the DPI functions.
+
+Before specifying these two aspects, it is necessary to introduce the basic structure of the DPI node and the typical network supporting DPI functions.
+
+## **7.2 Basic structure of a DPI node**
+
+The basic structure of a DPI node has been described in Figure 6-1 of [ITU-T Y.2770] and Figure 7-2 of [ITU-T Y.2771]; the realization of a DPI node can be based on the structure.
+
+## **7.3 Typical network supporting DPI functions**
+
+A typical network deployed with DPI nodes is described in Figure 7-1, where, from top to bottom, the five logical layers include: cloud, core layer, aggregate layer, access layer and terminal layer. It should be emphasized that a logical link exists between every DPI node and element management system (EMS) or network management system (NMS), though not all logical links are illustrated in Figure 7-1. All DPI nodes can cooperate with the network entities (such as router, switch and broadband remote access server (BRAS), etc.) and the DPI nodes in Figure 7-1 are independent of the above network entities.
+
+
+
+The diagram illustrates a hierarchical network architecture with three main horizontal layers separated by dashed lines: IP metro (top), Aggregate layer (middle), and Access layer (bottom).
+ At the top, a 'Core router' in a cloud connects to 'To other ISP'. Below it, 'BRAS' (Broadband Remote Access Server) units and 'Router/switch' units form the IP metro and Aggregate layers.
+ 'DPI nodes' (represented by blue ovals and magnifying glass icons) are strategically placed: one at the Core router, one at a BRAS, one at an Aggregate layer Router/switch, and one at an Access layer Switch.
+ Red dashed arrows indicate DPI monitoring paths.
+ The 'Access layer' contains multiple 'Switch' units connecting to end-user environments like 'VIP' (a cloud of PCs), 'LAN' (office buildings), and individual residential-style buildings.
+ Management systems 'NMS' (Network Management System) and 'EMS' (Element Management System) are shown on the right, connected to the network infrastructure.
+ The diagram is labeled 'Y.2772(16)\_F7-1' at the bottom right.
+
+**Figure 7-1 – An example network topology deployed with DPI nodes**
+
+Figure 7-1 – An example network topology deployed with DPI nodes
+
+For more information, see the example DPI applied network given in Figure 6-3 of [b-ITU-T Y-Sup.25].
+
+**7.4 DPI mechanism related to the DPI node**
+
+The DPI mechanism of the DPI node mainly includes the following three aspects:
+
+**1) Information representation method**
+
+A network element that supports DPI functions has various kinds of information and data to be represented in the element, for example, the DPI rules. The information representation method is very important to the network element; different representation methods bring about different processing efficiencies.
+
+**2) Processing methods and procedures**
+
+Processing methods and procedures include instructive methods for the realization of the DPI relative functions and as well as the procedures that a network element executes in supporting these DPI functions.
+
+**3) Interface and proper protocol**
+
+Interface and proper protocol include the realization of the interfaces that are defined in [ITU-T Y.2770] (e.g., e1, e2) as well as the appropriate protocol used for exchanging information between the above kinds of interface.
+
+**Rec. ITU-T Y.2772 (04/2016)** 5
+
+## **7.5 The mechanism of a network deployed with DPI nodes**
+
+The mechanism corresponding to the networks supporting DPI functions mainly including the following aspects:
+
+- operation aspects;
+- management aspects.
+
+# **8 Representation methods of the DPI – Policy rule of DPI-PIB**
+
+## **8.1 Overview**
+
+The DPI policy rule condition of DPI policy information base (DPI-PIB) is one of the core parts of a DPI node, and almost all actions of the DPI node are based on DPI policy rule conditions. Therefore, it is very important that the DPI policy rule condition is represented effectively and is easy to process. Three DPI policy rule condition representation methods are described: data and mask representation method, regular express representation method and hybrid representation method.
+
+## **8.2 Data and mask representation method for DPI policy rule conditions**
+
+The IP address and mask representation method is usually used in TCP/IP protocol stack and related network devices; the data and mask representation method is similar to the IP address and mask representation method. In the data and mask method, a byte string (data) is used to represent the tagged word that identifies a certain data flow, and a bit string (mask) corresponding to the byte string is used to decide whether a certain bit of the byte string should be checked or not. Generally, if a mask bit is '1', the corresponding bit of the byte string is not checked. Conversely, if a mask bit is '0', then the corresponding bit of the byte string requires checking.
+
+For the DPI-PIB, it is appropriate to use the data and mask representation method, which has the following advantages:
+
+- simple and easy to understand;
+- high efficiency, a single item can be shared by a many data flows;
+- matches well with the common used devices such as ternary content-addressable memory (TCAM).
+
+The following two examples illustrate the data and mask representation method:
+
+- 1) Match the data flows whose TCP source port range from 0x2100 to 0x21ff
+
+In the DPI-PIB, only one item is needed in order to meet the requirement:
+
+Item1: data: 0x2100, mask: 0x00ff
+
+- 2) Match the data flows whose virtual local area network (VLAN) is in the set 16-63
+
+In the DPI-PIB, two items are needed to meet the requirement:
+
+Item1: data: 0x0010, mask: 0x000f
+
+Item2: data: 0x0020, mask: 0x001f
+
+## **8.3 Regular expression representation method for DPI policy rule conditions**
+
+The data and mask representation method is appropriate to represent a tagged word with a fixed position and determinate value. Generally, layer 2 through layer 4 (L2-L4) protocol headers match this type of request very well.
+
+However, tagged words of high layer applications are usually uncertain and easy to change. Under such circumstance, using the data and mask representation method is hard to implement. In these
+
+applications, the regular express representation method is more appropriate for those kinds of tagged words.
+
+A regular expression [b-ITU-T X.680] is a well-known description method in computer science; the detailed presentation and analysis of regular expressions is outside the scope of this Recommendation.
+
+The following two examples illustrate the regular expression representation method:
+
+- 1) Match the data flow that includes the word "Bittorrent" or "Bitcomment"
+
+In the DPI-PIB, only one item is needed in order to meet the requirement:
+
+Item1: `"/Bit(torrent|comment)/"`
+
+- 2) Match the data flow that includes the word "Worm" where the following word is not "v1" or "v2"
+
+In the DPI-PIB, only one item is needed in order to meet the requirement:
+
+Item1: `"Worm(?>L-PDF: Identified Result
+ L-PDF-->>DPI-engine: Identified Result Confirmation
+ L-PDF->>PD-FE: Report Connection Request
+ PD-FE-->>L-PDF: Report Connection Confirmation
+ L-PDF->>PD-FE: Report Data
+ PD-FE-->>L-PDF: Report Data Confirmation
+ L-PDF->>PD-FE: Report Connection Cancelling Request
+ PD-FE-->>L-PDF: Report Connection Cancelling Confirmation
+
+```
+
+Y.2772(16)\_F9-1
+
+Sequence diagram showing DPI-engine oriented information flow between DPI-engine, L-PDF, and PD-FE.
+
+**Figure 9-1 – DPI-engine oriented information flow**
+
+In Figure 9-1, the primitive "Identified Result" is used to transport data generated by a DPI-engine, and the primitive "Identified Result Confirmation" is used to tell the DPI-engine that the above data have been received. The primitive couple "Report Connection Request" and "Report Connection Confirmation" is used to establish a connection, and the primitive couple "Report Data" and "Report Data Confirmation" are used to transport reported data. After finishing the exchange of all reported data, the primitive couple "Report Connection Cancelling Request" and "Report Connection Cancelling Confirmation" is optionally used to remove the connection (represented by dashed line in Figure 9-1).
+
+### 9.3.2 DPI-PIB oriented information flow
+
+Figure 9-2 depicts the information flow based on DPI-PIB. The data exchange between the DPI-PIB and the L-PDF is within the DPI entity, and the data exchange between the L-PDF and the PD-FE is beyond the DPI entity.
+
+In Figure 9-2, data exchange between DPI-PIB and L-PDF is recommended to be designed as connectionless mode, and data exchange between L-PDF and PD-FE is recommended to be designed as connection-based mode.
+
+
+
+```
+
+sequenceDiagram
+ participant PD-FE
+ participant L-PDF
+ participant DPI PIB
+
+ PD-FE->>L-PDF: Rule Connection Request
+ L-PDF-->>PD-FE: Rule Connection Confirmation
+ PD-FE->>L-PDF: Rule Data Request
+ L-PDF-->>PD-FE: Rule Data Confirmation
+ PD-FE->>L-PDF: Rule Connection Cancelling Request
+ L-PDF-->>PD-FE: Rule Connection Cancelling Confirmation
+ L-PDF->>DPI PIB: Rule Data Request
+ DPI PIB-->>L-PDF: Rule Data Confirmation
+
+```
+
+Y.2772(16)\_F9-2
+
+Sequence diagram showing DPI-PIB oriented information flow between PD-FE, L-PDF, and DPI PIB.
+
+**Figure 9-2 – DPI-PIB oriented information flow**
+
+In Figure 9-2, the primitive couple "Rule Connection Request" and "Rule Connection Confirmation" is used to establish a connection, and another primitive couple "Rule Data Request" and "Rule Data Confirmation" is used to transport rule data. After finishing the exchange of all rule data, the primitive couple "Rule Connection Cancelling Request" and "Rule Connection Cancelling Confirmation" is optionally used to remove the connection (represented by a dashed line in Figure 9-2).
+
+### 9.3.3 DPI L-PDF oriented information flow
+
+Figure 9-3 depicts the DPI L-PDF oriented information flow. Both the data exchange between the L-PDF and the PD-FE and the data exchange between the L-PDF and the Management Entity are outside the DPI entity.
+
+In Figure 9-3, among the three functional components including PD-FE, L-PDF and Management Entity, no two components belong to a single entity. Therefore, mutual data exchange is recommended to be designed as connection-based mode.
+
+In Figure 9-3, four primitive couples (including "Rule Connection Request" and "Rule Connection Confirmation", "Rule Synchronization Connection Request" and "Rule synchronization Connection Confirmation", "Report Connection Request" and "Report Connection Confirmation", and "Config Connection Request" and "Config Connection Confirmation") are used to establish a corresponding connection. Meanwhile, four other primitive couples (including "Rule Data Request" and "Rule Data Confirmation", "Rule Data Request" and "Rule data Confirmation", "Report Data Request" and "Report Data Confirmation", "Config Data Request" and "Config Data Confirmation") are used to transport corresponding data. In addition, corresponding to every type of connection, after finishing the exchange of all corresponding data, the primitive couple "... Connection Cancelling Request" and "... Connection Cancelling Confirmation" is optionally used to remove the connection. These last-mentioned primitive couples are not depicted in Figure 9-3 to reduce complication and avoid confusion in the figure, however, they have similar functions as the primitive couple "Rule Connection Cancelling Request" and "Rule Connection Cancelling Confirmation".
+
+
+
+```
+
+sequenceDiagram
+ participant PD-FE
+ participant L-PDF
+ participant Management entity
+
+ PD-FE->>L-PDF: Rule Connection Request
+ L-PDF-->>PD-FE: Rule Connection Confirmation
+ L-PDF->>PD-FE: Rule Data Request
+ PD-FE-->>L-PDF: Rule Data Confirmation
+
+ L-PDF->>Management entity: Rule Synchronization Connection Request
+ Management entity-->>L-PDF: Rule Synchronization Connection Confirmation
+ L-PDF->>Management entity: Rule Data Request
+ Management entity-->>L-PDF: Rule Data Confirmation
+ L-PDF->>Management entity: Report Connection Request
+ Management entity-->>L-PDF: Report Connection Response
+ L-PDF->>Management entity: Report Data
+ Management entity-->>L-PDF: Report Data Confirmation
+ L-PDF->>Management entity: Config Connection Request
+ Management entity-->>L-PDF: Config Connection Confirmation
+ L-PDF->>Management entity: Config Data
+ Management entity-->>L-PDF: Config Data Confirmation
+
+```
+
+Sequence diagram showing L-PDF oriented information flow between PD-FE, L-PDF, and Management entity.
+
+Y.2772(16)\_F9-3
+
+**Figure 9-3 – L-PDF oriented information flow**
+
+## 9.4 Process procedure
+
+### 9.4.1 DPI-engine process procedure
+
+When a packet enters into the DPI-engine, the DPI-engine scans and identifies the packet according to the policy rule defined in DPI-PIB. Then analyser of DPI-engine analyses the identified packet, and records the analysed result. After that, the policy action will be executed according to the identified result.
+
+If the packet is not identified, the 'non-identified' action will be performed. If the packet is identified, DPI-engine will execute the corresponding action according to the policy rule defined in DPI-PIB.
+
+Meanwhile, DPI-engine records the identified result of each packet, and caches several similar results. It reports the results to the management entity periodically. The report period is specific to realization, and is outside of the scope of this Recommendation.
+
+### 9.4.2 DPI-PIB process procedure
+
+DPI-PIB contains a set of one or multiple DPI policy rule entries. DPI-PIB receives rule data from L-PDF after L-PDF received rule data from PD-FE.
+
+### 9.4.3 L-PDF process procedure
+
+The L-PDF updates the rule entries for the DPI-PIB when it receives rule data from remote policy decision function(s) (PDF(s)). The L-PDF send identified result to remote PDF(s) when it receives identified result from DPI-engine. The L-PDF may be also responsible for resolving possible rule interaction problems between the set of DPI policy rules.
+
+## **9.5 Protection method**
+
+[ITU-T Y.2771] has defined "1+N" redundancy group to realize the fault tolerance. There are two distinct protection models: the "1+1" ( $N=1$ ) model and the "1+N" ( $N>1$ ) model. The "1+1" model is used for one active component and one standby component, while the "1+N" ( $N>1$ ) model is used for one active component and $N$ standby components.
+
+### **9.5.1 "1+1" model**
+
+The "1+1" model is also called the active/standby model and represents a kind of failover model where, in case of a failure, an idle standby component takes over for the failed component. In this model, the standby component uses a heartbeat mechanism to detect the failure of the active component. The level of high-availability depends on the replication strategy for component status. For an active/standby model, the hot-standby solution is recommended to be used. A hot-standby solution provides hardware redundancy as well as software redundancy. However, the status of the active component is replicated to the standby component on any change, i.e., the status of the standby component is always up-to-date. In case of a failure of the active component, the standby component replaces the failed component and continues to operate based on the current status.
+
+Component status is copied using active replication. A commit protocol is used to announce status changes to the standby component before they are executed at the active component. Once executed, the standby component receives a second message to commit the status change. Any uncommitted status changes are executed by the standby component upon failover. The commit protocol is specific to realization, and is outside of the scope of this Recommendation.
+
+The active/hot-standby model offers continuous availability without any interruption of service.
+
+### **9.5.2 "1+N" ( $N>1$ ) model**
+
+The "1+N" ( $N>1$ ) model is based on multiple redundant component, and more than two DPI components (in other words, a DPI "1+N" redundancy group of which the DPI components are the functional components) are designed within a DPI node, and one DPI component works as the active component while the other DPI components operate as backup components.
+
+The process procedures of this mode is similar to the "1+1" model. The backup components use heartbeat messages to detect the failure of active component. When the active component has failed, one of backup components takes over the failed component.
+
+## **9.6 Data synchronization method**
+
+Data synchronization needs to be considered in case protection switchover occurs. The active functional components and the backup functional components are recommended to keep totally identical information such as policy information base (PIB) through a data synchronization method.
+
+### **9.6.1 Data synchronization in "1+1" mode**
+
+In case of the active component (including DPI-node, DPI-engine and DPI-FE) failure, the backup component takes over the work of the active component. The backup component needs to send 'Rule Synchronization Request' to the management entity. The management entity will send the rule data to the backup component.
+
+#### **9.6.2 Data synchronization in component level "1+N" ( $N>1$ ) mode**
+
+The data synchronization in component level "1+N" mode is similar with "1+1" mode. In case of active component (including DPI-node, DPI-engine and DPI-FE) failure, the backup component takes over the work of active component. The backup component needs to send 'Rule Synchronization Request' to the management entity. The management entity will send the rule data to the backup component.
+
+### 9.6.3 Data synchronization in node level "1+N" (N>1) mode
+
+The node level "1+N" (N>1) mode is realized using cluster mode. In cluster mode, if the master node fails, the backup node takes over the work of master node. The backup node will synchronize the rule data from management entity.
+
+In case of slave node failure, the traffic passed to the failed node will redistribute to the other slave nodes by upstream routers according the load balance algorithm. These slave nodes will be triggered to synchronize the new rules from the management entity.
+
+# 10 Operational mechanism specification
+
+## 10.1 Overview
+
+This clause depicts operational aspects of DPI technologies, including the following aspects:
+
+- goals of adopted DPI technology;
+- performance aspect of DPI system deployment;
+- analysis of the current networks without DPI;
+- deployment of DPI physical entities and setting up relative networks;
+- operation, administration and maintenance of the DPI relative networks;
+- changing and improving current networks based on monitoring performance of the current networks.
+
+The general process to build and operate a network with DPI nodes is depicted in Figure 10-1. The functions of the six steps depicted in the figure are described in clauses 10.3 to 10.8.
+
+
+
+```
+graph TD; A[Analyzing the current network] --> B[Confirming the DPI requirement of the network]; B --> C[Choosing proper DPI products (DPI nodes)]; C --> D[Reconstructing the current network using DPI nodes]; D --> E[Monitoring and managing the network with DPI]; E --> F[Optimizing the network with DPI based on performance monitor]; F --> A;
+```
+
+Y.2772(16)\_F10-1
+
+Flowchart illustrating the process to build and operate a network with DPI nodes. The process consists of six sequential steps: Analyzing the current network, Confirming the DPI requirement of the network, Choosing proper DPI products (DPI nodes), Reconstructing the current network using DPI nodes, Monitoring and managing the network with DPI, and Optimizing the network with DPI based on performance monitor. A feedback loop arrow connects the final step back to the first step.
+
+**Figure 10-1 – Illustrating the process to build and operate a network with DPI nodes**
+
+## **10.2 Objectives of the operation mechanism**
+
+### **10.2.1 Overall objective**
+
+The general objectives for applying DPI relative technologies include the following three aspects:
+
+- 1) monitoring the status of the current network;
+- 2) instructing operators to rebuild and optimize network;
+- 3) improving the network performance.
+
+### **10.2.2 Specific objectives**
+
+The specific objectives of operation mechanism can be listed as follows:
+
+- deploying DPI nodes without influencing current on-line service;
+- monitoring all kinds of traffic of the active network;
+- identifying the invalid traffic defined in policy rules;
+- analysing the status of the network based on detail network performance monitoring;
+- reallocating network resources based on network status analysing;
+- rebuilding and improving network based network status;
+- improving the satisfaction level of network users.
+
+## **10.3 Performance aspect or DPI nodes deployment**
+
+In principle, the deployment of DPI nodes should not interrupt the current network services and applications. However, in practice there may be some negative effects on network services and applications while a DPI node is being installed into the network. After installation, the negative influence introduced by DPI node deployments should meet special requirements.
+
+### **10.3.1 Out-of-path DPI nodes deployment specification**
+
+While an out-of-path DPI node is being inserted into a network, services and applications interrupt time of the current network should be less than 50 milliseconds. Theoretically, deploying out-of-path DPI nodes can be carried out without interrupting services and applications.
+
+### **10.3.2 In-path DPI nodes deployment specification**
+
+While an in-path DPI node is being inserted into a network, services and applications interrupt time of the current network should be less than 50 milliseconds. By using auxiliary methods or instruments, the 50 milliseconds target can be achieved. For example, use a redundant link first before deploying the in-path DPI node, then remove the redundant link when the in-path DPI node can work normally.
+
+## **10.4 Analysis of current networks**
+
+Before deploying a DPI node, some information about the current network need to be achieved, e.g., the maximum bandwidth of all network segments, active average traffic of the network segments, traffic distribution of the network segments according to date and time, influence degree while deploying a DPI node. Typically, this information can be collected by the NMS of the present network.
+
+Through analysing this information, the design scheme of building a network with DPI functions can be achieved.
+
+## **10.5 Confirming the DPI requirement of the network**
+
+Collect and confirm the requirement of DPI node based on the above analysis of the current network.
+
+## 10.6 Choosing proper DPI entities or systems
+
+DPI entities used to construct the network with DPI functions should meet the requirement described in clause 10.4.
+
+## 10.7 Reconstructing the current network using DPI
+
+Deploying DPI devices should not reduce the performance of the current network, and especially the on-line service should not be impacted. Out-of-path DPI physical entities can be set up more conveniently than in-path DPI physical entities, however improper operations are possible to influence the service. Therefore, the proper time and location should be selected to minimize the above influence, and the time and location selection should be dependent on the network on-line traffic.
+
+As a point of emphasis, a DPI node should support an internal bypass function when it is deployed in the network and it works as in-path DPI node. Figure 10-2 depicts the internal bypass function, and the dashed line represents the bypass. When the packet flows are carried on the bypass, it is equivalent to the DPI node not being in the network. In other words, it appears to the packet flows that the network device prior to the DPI node connects with the network device following the DPI node directly.
+
+![Diagram of the internal bypass function of a DPI node. The diagram shows a large box labeled 'DPI policy enforcement function (DPI-PEF) [unidirectional]'. Inside this box is a 'DPI policy information base (DPI-PIB)'. Below the PIB are three sequential blocks: 'DPI scan function (DPI-ScF)', 'DPI analyzer function (DPI-AnF)', and 'DPI action execution function (DPI-AcEF)'. A solid line represents the normal processing path: 'Ingress packet flows' enter from the left, pass through the three functions, and exit as 'Egress packet flows' on the right. A dashed line represents the bypass path, which goes from the input, bypasses the three functions, and goes directly to the output. Arrows from the DPI-PIB point to the dashed bypass line, labeled 'Condition(s)' and 'Conditions and actions'. The identifier 'Y.2772(16)_F10-2' is at the bottom right.](7d3d5fb5d09c0cd35a9d637be241651e_img.jpg)
+
+Y.2772(16)\_F10-2
+
+Diagram of the internal bypass function of a DPI node. The diagram shows a large box labeled 'DPI policy enforcement function (DPI-PEF) [unidirectional]'. Inside this box is a 'DPI policy information base (DPI-PIB)'. Below the PIB are three sequential blocks: 'DPI scan function (DPI-ScF)', 'DPI analyzer function (DPI-AnF)', and 'DPI action execution function (DPI-AcEF)'. A solid line represents the normal processing path: 'Ingress packet flows' enter from the left, pass through the three functions, and exit as 'Egress packet flows' on the right. A dashed line represents the bypass path, which goes from the input, bypasses the three functions, and goes directly to the output. Arrows from the DPI-PIB point to the dashed bypass line, labeled 'Condition(s)' and 'Conditions and actions'. The identifier 'Y.2772(16)\_F10-2' is at the bottom right.
+
+Figure 10-2 – Internal bypass function of a DPI node
+
+## 10.8 Monitoring and managing the network with DPI
+
+In general, networks that incorporate DPI functions are more complex than networks without DPI functions. Therefore, a DPI network should always use operation, administration and maintenance (OAM). That is, the DPI nodes and their PIB should be maintained and managed.
+
+## 10.9 Rebuilding the network with DPI based on performance monitor
+
+In general, building a network that incorporates DPI functions is an adaptive process. The network structure should be adjusted gradually based on network performance status changes. Monitoring network status depends on appropriate data and statistical analyses.
+
+# 11 Specification of management mechanism
+
+## 11.1 Overview of DPI network management
+
+Just like any typical network element, a DPI node should support configuration, fault, performance and security management functions. These management functions have been defined in the other
+
+Recommendations and are outside of the scope of this Recommendation. However, some special considerations to be taken on management of DPI networks are identified here.
+
+Under bidirectional DPI application environments, the bidirectional DPI functions can be realized by either a single DPI node (single node mode, see Figure 11-1) or by a pair of DPI nodes (double nodes mode, see Figure 11-2). Under many circumstances, double nodes mode is more advantageous than single node mode. For example, when some special traffic needs to be blocked, then the above special traffic can be blocked earlier when using double nodes mode.
+
+Because it is possible that the two related DPI nodes are deployed physically independent, and the management of these DPI nodes needs to be unified, the management will be more complex because under such circumstances network management should be in sub-network level rather than at the node level.
+
+
+
+The diagram shows a network topology for single node mode. At the center is a blue router with four ports. Four blue square switches are connected to the router's ports. Each switch is connected to a group of desktop computers. A single DPI node, represented by a square with a circular lens, is connected to the central router. Dashed purple arrows labeled 'DPI functions' point from the DPI node to each of the four switches. Red dashed arrows labeled 'Traffic' show bidirectional flow between the desktop computers and the switches, passing through the DPI node. The label 'DPI node' is placed near the central router.
+
+Diagram illustrating Bidirectional DPI functions carried out by a single DPI node (single node mode).
+
+Y.2772(16)\_F11-1
+
+**Figure 11-1 – Bidirectional DPI functions carried out by a single DPI node (single node mode)**
+
+
+
+Figure 11-2: Bidirectional DPI functions carried out by a pair of DPI nodes (double nodes mode). The diagram shows a network topology with multiple routers and switches. Two specific DPI nodes are highlighted, each represented by a server icon with a lock. These nodes are connected to a central router. Dashed red arrows labeled 'Traffic' show data flow passing through the DPI nodes. Dashed purple arrows labeled 'DPI functions' show the interaction between the DPI nodes and the central router. The label 'DPI node' points to one of the server icons. The label 'DPI functions' points to the dashed purple arrows. The label 'Traffic' points to the dashed red arrows. The diagram is identified by the code Y.2772(16)\_F11-2 in the bottom right corner.
+
+**Figure 11-2 – Bidirectional DPI functions carried out by a pair of DPI nodes (double nodes mode)**
+
+## **11.2 Management interface**
+
+### **11.2.1 Unidirectional DPI management interface**
+
+The general management of the unidirectional DPI can be as depicted in Figure 11-3, where the connection between a DPI node and the network management system (NMS) is not a physically direct connection, but rather a logical connection through a sub-network. This link between a DPI node and an NMS is represented by a dashed line in the figure. Logically, the management interface between the DPI node and the NMS can be described as follows:
+
+Command line interface (CLI): the NMS manages and controls the DPI node through a serial port, and management action takes effect through a series of single-line commands. The NMS can manage only one online DPI node at a time.
+
+Graphical user interface (GUI): the NMS manages and controls the DPI node through an Ethernet port or the other kind of physical port, and management action takes effect through exchanging a group of protocol packets between the DPI node and the NMS. The NMS can manage one or more online DPI node concurrently.
+
+Telnet interface: the NMS manages and controls the DPI node through an Ethernet port or the other kind of physical port, and management action takes effect through a series of single-line commands. The NMS can manage only one online DPI node at a time.
+
+
+
+The diagram shows a 'Network management system' at the top, represented by a computer icon. Below it, a dashed line labeled 'Management interface e2' connects the NMS to a cloud-shaped network. Inside the cloud, there are four nodes: two are labeled 'DPI node' and two are labeled 'Other network node'. Dashed lines connect the NMS to each of the two 'DPI node' nodes. The label 'Y.2772(16)\_F11-3' is located at the bottom right of the cloud.
+
+Diagram illustrating the network management of unidirectional DPI. A Network management system (NMS) is connected via Management interface e2 to two DPI nodes within a network cloud. The cloud also contains other network nodes. The diagram is labeled Y.2772(16)\_F11-3.
+
+**Figure 11-3 – Network management of unidirectional DPI**
+
+### 11.2.2 Bidirectional DPI management interface
+
+The management of the bidirectional DPI can be as depicted in Figure 11-4. Compared with unidirectional DPI management, bidirectional DPI (see the above Figures 11-1 and 11-2) may be more complex because the two or more DPI nodes are inter-dependent. Thus, some connections between two DPI nodes should be set up, certainly. These connections are not necessarily physically direct connections, but can be connections through a sub network or through an NMS. These links are represented by the dashed lines in Figure 11-4. In addition to the unidirectional DPI management interface, the following management interface should be used in bidirectional DPI management:
+
+Interface e3 (see Figure 11-2): the interface between two relative DPI nodes that is used to guarantee the information unity of the two DPI nodes and keep the logically connection between two relative DPI nodes.
+
+In bidirectional DPI application scenarios, it is more efficient and economical to realise bidirectional DPI functions based on cooperation between a pair of DPI nodes with one DPI node being responsible for the DPI function of one direction and the other DPI node being in charge of the DPI function of the counter direction. Therefore, PIBs in the two DPI nodes should be correlative; changes of PIB in one DPI node should cause associated modification of PIB in another DPI node.
+
+For example, if bidirectional DPI functions on the traffic between network device A and B are required to be carried out, then the policy control rule relative to a flow from A to B should be set up in one DPI node, while the policy control rule relative to data flow from B to A should be configured in another DPI node. Note that the network management system need only inform the DPI nodes that they are required to realize bidirectional DPI function on traffic between A and B. PIB configuration in the two DPI nodes should be completed automatically by the DPI nodes and thus, information exchanging between the DPI nodes is necessary and is carried out through interface e3.
+
+Moreover, in order to exchange information between the DPI nodes, some protocol should be used to make the DPI nodes connective and the protocol data packets are also communicated through interface e3.
+
+
+
+The diagram shows a Network management system (NMS) at the top, represented by a computer icon. Below it is a light blue cloud representing a network. Inside the cloud, there are four DPI nodes: DPI node A, DPI node B, DPI node C, and DPI node D. DPI node A is at the top, DPI node B is at the bottom left, DPI node C is at the bottom center, and DPI node D is at the bottom right. Dashed lines represent connections: two lines labeled 'Management interface e2' connect the NMS to DPI node A and DPI node B; a line labeled 'Interface e3' connects DPI node A to DPI node B; and a line connects DPI node A to DPI node D. There are also two 'Other network node' icons (represented by routers) within the cloud. The text 'Y.2772(16)\_F11-4' is located at the bottom right of the cloud.
+
+Diagram illustrating Network management of bidirectional DPI. A Network management system (NMS) is connected via Management interface e2 to DPI node A. DPI node A is connected via Interface e3 to DPI node B and DPI node D. DPI node B is connected via Management interface e2 to the NMS. DPI node D is connected via Management interface e2 to the NMS. Other network nodes are also present in the network.
+
+**Figure 11-4 – Network management of bidirectional DPI**
+
+## 11.3 Management protocol and functions
+
+The management protocol between the NMS and the DPI node or the DPI subnetwork may be simple network management protocol (SNMP), common management information protocol (CMIP) or any other management protocol.
+
+The management functions include traditional configuration management, alarm management and performance management. In addition, bidirectional DPI subnetwork PIB maintain function should be adopted in the NMS.
+
+# 12 Security consideration
+
+Regulation, privacy, security application aspects of DPI are outside the scope of this Recommendation. Vendors, operators and service providers are required to take into account national regulatory and policy requirements when implementing this Recommendation.
+
+According to [ITU-T Y.2770], the DPI-FE and the information pertaining to DPI operations should be under protection against threats. The mechanisms specified in [ITU-T Y.2704] address the security requirements of [ITU-T Y.2770].
+
+# Bibliography
+
+- [b-ITU-T X.200] Recommendation ITU-T X.200 (1994), *Information technology – Open Systems Interconnection – Basic Reference Model: The basic model.*
+- [b-ITU-T X.680] Recommendation ITU-T X.680 (2015), *Information technology – Abstract Syntax Notation One (ASN.1): Specification of basic notation.*
+- [b-ITU-T Y-Sup.25] ITU-T Y.2770-series Recommendations – Supplement 25 (2015), *Supplement on DPI use cases and application scenarios.*
+- [b-IETF RFC 3198] IETF RFC 3198 (2001), *Terminology for Policy-Based Management.*
+- [b-IETF RFC 5101] IETF RFC 5101 (2008), *Specification of the IP Flow Information Export (IPFIX) Protocol for the Exchange of IP Traffic Flow Information.*
+
+
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a3e5fece5698e8ba520b3f82ea882cccdbf2ccb8
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1d126a35b41a684c9239fa472187940d71fda21829eb81d1339b69264c8b19ce
+size 34011
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7625e18c3bc1a31d5372eea606370fcf789ca2b9
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f2ff558fc7658f48ec610bf9ffcb24a0b937143eaa43de745f88110fd301eec4
+size 123420
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..de2ba47631c6589b2245a0ecad2f37a76317cb07
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1a6e3e571711673e03bcdbb5eb93f4154459772a1069b65fa22bf2f995ca832d
+size 6963
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c194d12e48737eb79363c928a2925e7470b499ca
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:df10ae68020919e52fe71f520e0df3aaf5d217ceabb49c1a653d1066b753207d
+size 113677
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d1f8d2e25247fedd7d587aea47877f32147cab1a
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:583df8c04adf75db0b787d79802f6ed2f81a45053d379fb6c6c25fa7e5a2b0f1
+size 32253
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..17ae8208aa1a2089258cc959f334fc74cf7dabc7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:287fa8ab8b81ffe7a3acffc023a246ccff571c9f82e8a82d6308aae6944f8b7b
+size 32420
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/bffdddb47fced140f8d17fdc2a29f592_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/bffdddb47fced140f8d17fdc2a29f592_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..441d73625c9633bfa6e0fe76eff94f49fa783568
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/bffdddb47fced140f8d17fdc2a29f592_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:085669161e19ffb581e9ee0db0e9b3b258df616edf4cc4690ee0c6cc705022bd
+size 30718
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..838b4b43fbeab5c124e81a84c13982e2cfbff395
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d0b0198490957d654dfdf4416dfe481a89be4f6d3638173cd150907b6242e650
+size 55648
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7d952a964565c0f065e377af83e1799e8e76e089
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:349c8ecc32b69915e8b16892d6265607354b8719dca6b78f3ea301104bd52455
+size 67544
diff --git a/marked/Y/T-REC-Y.2815-201812-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bde3341a21aaf8986f496369ab44e3f738dcf262
--- /dev/null
+++ b/marked/Y/T-REC-Y.2815-201812-I_PDF-E/ff7ce44f3fdd51bae7b231f34df07c6a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fad9b195dfba9803f8e35de6a09d97810375b03803b657856e88069d31c37b02
+size 57438
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2574b7212f9ff6036b9db460a86c688123486b28
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/724c7777b608e53be38b12b6fb3c43bc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:30e3352b71a47eb0fad36364d1a189aa6f7791c8183609309587b0b9174efb46
+size 103553
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c44ad589cd23854de0326146b710e4ea75f570c4
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:03467c882a01b3f522921253c60d2961edbc1ee5739097f22bda8ac436571682
+size 8256
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..47c68c9829ef7333e3dc507a0dd8d7c76f42fcca
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9e3cc321d5a7159a95bb3b4652afadbac77831d64723ba375ab7506ec7466c1f
+size 120023
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..54a1857788e4752dc3052707451accb6e01ab1d7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2285b9860e91351c295be16b9859a9d6cc569c13e984db9957aec56187cccb64
+size 116990
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a36b885403349c3069579d0091e20570771f1bc7
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b54284f23401787b2a5244b1c0921ace03b97d25eee56abd336fc704b040ea9a
+size 68162
diff --git a/marked/Y/T-REC-Y.2901-200612-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f8dd177ae8941025d9e2c70545221906edc56516
--- /dev/null
+++ b/marked/Y/T-REC-Y.2901-200612-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5a03d188fd42da7fc4e70073bac0b015acf661270d74f6cdfed2dc71103c9d24
+size 116472
diff --git a/marked/Y/T-REC-Y.3012-201404-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3012-201404-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1171e4367afffe1dc419450738341bf109161e7a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3012-201404-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6dc4e10c034bea218d2805eed6248e0a36582dd1663f4a59a91f478b03d31b08
+size 6923
diff --git a/marked/Y/T-REC-Y.3012-201404-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg b/marked/Y/T-REC-Y.3012-201404-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fb0f561c7957781e421aa5941bc14f767c1f4eb1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3012-201404-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b66b5640e470806233284479e562e4627e49b981816b45f826063725a7acac49
+size 103701
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9cfec5d65d5d9ac3d714e134e11d463ebf79f5b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:eca08b8f5c8b504114844c9603e17989267cea9f278a31ccb7b1a7efd464e292
+size 79545
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3fd3e4fa5762e41e5a5c71fe19835e7ddeae81b8
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:58d59033be2ce537774882b01afc0aaa0919b40567fe88d806d900985ab4df80
+size 96653
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d65d7d67d061f81f3baeb8bef20e5b1ed9a57cb1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:571eb44eec3666d0624d9d59a5cb491830a377dbde76f34abb3bff88263029e4
+size 96049
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1721c25a27fe088d46b665e73c7314c91caed56a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:95bc8cd6b77c20f91c81d7a7b3481e9bb8389227e70a05796a5cf392814fc293
+size 94349
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2659b0142ffae183f75f62178e86f9291ec862b0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:75fb906f2b1cdda9d1c256bc33e51d4a363b82065d54bf3c28d948d8bbe1052d
+size 75863
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..250570427f13f174ba76fb475398463dbc43873e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5f57ddc3ae4d0ccb217708d24195cdf6ae2ec1321ef97482d6f89cebd2dd82da
+size 69928
diff --git a/marked/Y/T-REC-Y.3014-201602-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..73ca48710fc7d0a7194052ea5089b0f487b694d7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3014-201602-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c0d3d19749b46b40ce5a9adfec75814c8239a51b23e9099a50a87a5ac1f501f9
+size 110551
diff --git a/marked/Y/T-REC-Y.3033-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3033-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3357909623ec0aa9c2b114ea223e25073e444da2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3033-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ea0bfbc2c84674831dfd3d7088fb930b584314c9c5738008024d5da6c6a67e94
+size 6505
diff --git a/marked/Y/T-REC-Y.3033-201401-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg b/marked/Y/T-REC-Y.3033-201401-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..71cb93517f088b6b4098968de5601aab11d8dd10
--- /dev/null
+++ b/marked/Y/T-REC-Y.3033-201401-I_PDF-E/cfda9df1319e04207eb28bcefd1dab7b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:36521e22fbdb63b8bfe9edbe527e429ffcaa84f8f10455b28b7a075df689e9e7
+size 35987
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0fd5d57994fc417b60c3db9db4fd7091764b6b8b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:500fb255bd4444f427d981a8afb9c81a3e7488619f86c11c20e2f1bf3f9a33ce
+size 59806
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..625b2b8522764f012c8844b8552fefea47553576
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d75a976bce4a43202d16c861a5aca552d526a867fe5cbbf335bd883c4f62cab4
+size 70609
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..17728066902467ad8abf1dc342acb57ead962f13
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee6e2dafc0bac54eb654ff62b51b3b5aa18dd97e73edc73a2e845b8a7943bc6a
+size 103930
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0583d90baaa53581b68e918ff4aca8967ba6cf21
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:62a8d1ce04f35ce6cef75f5c1f13ca072ef11c2f6217d4db3886043beb1af5d9
+size 76975
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..83de44cfa91ff96cd6d044185230bbdca1aff85e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:92c3c68bcdb95caa413d3d9a4747655489556a99ef57b3def4ad289d99ef7337
+size 6615
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..da09e8f8840a402a0648cbc9a19af7c95a620e9c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c3dd20e3925628a443f20829335fb35e5946aa9ff7de2d4e0b512ff0dbf29b04
+size 37910
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f4f26563dd4ace17d1c8b1579f4a091bf65d53f3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dbc6e121fabd86f108ff3fa2d4c6068838678fd610d76f10cf7552cf4b93eb1d
+size 75381
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0c343cb73058d3ecb211fb6eb4589e101c2aa3f3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2c6f2f0f8a066c30941810813e84b9a489e6f3396edf2ad8357b1cf6b318c3f1
+size 66251
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e1b864ace1c5a142c5e53e48af6628dabaa6b790
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5649f4c5740bdaae2979d86c96f8928dacf2e37e4ae30e7dc283f5bce6941c3e
+size 41508
diff --git a/marked/Y/T-REC-Y.3045-201401-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..43ff065c6c9e34597ac1cf6f0d5e61b8a6cc245a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3045-201401-I_PDF-E/raw.md
@@ -0,0 +1,764 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.3045
+
+(01/2014)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Future networks
+
+# --- **Smart ubiquitous networks – Functional architecture of content delivery**
+
+Recommendation ITU-T Y.3045
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with two red lightning bolts striking it. To the right of the globe, the text "ITU" is written in a large, bold, blue font, and below it, the words "International Telecommunication Union" are written in a smaller, blue font.
+
+ITU logo: a blue globe with red lightning bolts and the text 'ITU International Telecommunication Union'
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+# GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## **FUTURE NETWORKS**
+
+**Y.3000–Y.3499**
+
+## CLOUD COMPUTING
+
+Y.3500–Y.3999
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.3045
+
+# Smart ubiquitous networks – Functional architecture of content delivery
+
+## Summary
+
+Recommendation ITU-T Y.3045 specifies the functional architecture of content delivery in smart ubiquitous networks (SUN) by describing the relevant capabilities, functions, operations and informational flows.
+
+The features of SUN content delivery are name-based content routing, in-network content caching, content delivery optimization, and dynamic content routing adaptive to context information whose principles are content awareness and context awareness as defined in Recommendations ITU-T Y.3044 and ITU-T Y.3043, respectively.
+
+The content delivery in SUN consists of content publication, content service provisioning, content routing and content caching as capabilities to support the aforementioned features.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3045 | 2014-01-13 | 13 | 11.1002/1000/12077-en |
+
+## Keywords
+
+Content delivery, SUN.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+### INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2014
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|----------------------------------------------------------------|------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 2 |
+| 6 | Overview ..... | 2 |
+| 7 | Features and capabilities for SUN content delivery ..... | 3 |
+| 8 | Functional architecture ..... | 4 |
+| | 8.1 Content service coordination function..... | 5 |
+| | 8.2 Content delivery control function..... | 5 |
+| | 8.3 Content delivery service function..... | 5 |
+| 9 | Content delivery operations ..... | 6 |
+| | 9.1 Content publications..... | 6 |
+| | 9.2 Content service provisioning..... | 7 |
+| | 9.3 Content routing..... | 7 |
+| | 9.4 Content caching..... | 7 |
+| 10 | Informational flows ..... | 7 |
+| | 10.1 Content publication ..... | 7 |
+| | 10.2 Content service provisioning..... | 9 |
+| | 10.3 Content routing..... | 10 |
+| | 10.4 Content caching..... | 10 |
+| 11 | Environmental considerations ..... | 11 |
+| 12 | Security considerations..... | 11 |
+| 13 | Accessibility considerations ..... | 11 |
+| | Appendix I – Use cases for context-aware content delivery..... | 12 |
+| | Bibliography..... | 14 |
+
+
+
+## Recommendation ITU-T Y.3045
+
+# Smart ubiquitous networks – Functional architecture of content delivery
+
+## 1 Scope
+
+This Recommendation provides the functional architecture of content delivery in smart ubiquitous networks (SUN) by specifying the relevant capabilities, functions, operations and informational flows. The capabilities of content delivery in SUN are identified considering content-awareness [ITU-T Y.3044] and context-awareness [ITU-T Y.3043] capabilities of SUN.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.3041] Recommendation ITU-T Y.3041 (2013), *Smart ubiquitous networks – Overview*.
+- [ITU-T Y.3043] Recommendation ITU-T Y.3043 (2013), *Smart ubiquitous networks – Context awareness framework*.
+- [ITU-T Y.3044] Recommendation ITU-T Y.3044 (2013), *Smart ubiquitous networks – Content awareness framework*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 content awareness** [ITU-T Y.3044], clause 6: An ability to identify, retrieve and deliver contents efficiently based on the content-related information considering location and/or user.
+
+**3.1.2 context** [b-ITU-T Y.2002]: The information that can be used to characterize the environment of a user.
+
+NOTE – Context information may include where the user is, what resources (devices, access points, noise level, bandwidth, etc.) are near the user, at what time the user is moving, interaction history between person and objects, etc. According to specific applications, context information can be updated.
+
+**3.1.3 context awareness** [b-ITU-T Y.2201]: Context awareness is a capability to determine or influence a next action in telecommunication or process by referring to the status of relevant entities, which form a coherent environment as a context.
+
+**3.1.4 Smart Ubiquitous Networks (SUN)** [ITU-T Y.3041]: IP-based packet networks that can provide transport and delivery of a wide range of existing and emerging services to people and things. The services provided by the SUN can cover aspects such as control, processing and storage.
+
+NOTE 1 – The network is smart in the sense that it is knowledgeable, context-aware, adaptable, autonomous, programmable and can effect services effectively and securely.
+
+NOTE 2 – The network is ubiquitous in the sense that it allows access anytime anywhere through varied access technologies, access devices including end user devices, and human-machine interfaces.
+
+### **3.2 Terms defined in this Recommendation**
+
+None.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|-----------------------------------------------|
+| AAA | Authentication, Authorization, and Accounting |
+| CN-FE | Content Name resolution Functional Entity |
+| CP-FE | Content Publication Functional Entity |
+| CR-FE | Content Routing & caching Functional Entity |
+| CS-FE | Content Service Functional Entity |
+| CT-FE | Content Transfer Functional Entity |
+| DNS | Domain Name Server |
+| FE | Functional Entity |
+| HTTP | Hyper Text Transfer Protocol |
+| SO-FE | Service node Optimization Functional Entity |
+| SUN | Smart Ubiquitous Networks |
+| URL | Uniform Resource Locator |
+
+## **5 Conventions**
+
+None.
+
+## **6 Overview**
+
+Smart ubiquitous networks (SUN) are IP-based packet networks that can provide transport and delivery of a wide range of existing and emerging services to people and things [ITU-T Y.3041]. While the services provided by the SUN can cover aspects such as control, processing and storage, one of the essential services is content delivery.
+
+The SUN content delivery mainly focuses on the how to deliver the content efficiently in a content and context aware manner. In other words, the content delivery exploits context information to adapt to the dynamic user characteristics and environment, and content aware capabilities of the network to provide personalized and optimized services. The details about context information and content aware capabilities are described in the context awareness framework [ITU-T Y.3043] and the content awareness framework [ITU-T Y.3044], respectively.
+
+Based on the aforementioned characteristics, the SUN content delivery provides the following high-level features:
+
+- Name-based content routing for content location discovery.
+- In-network content caching for intermediate content storages.
+- Content delivery optimization using in-network caches and path control.
+- Dynamic content routing adaptive to context information.
+
+In this Recommendation SUN content delivery is described in detail. First, it provides several capabilities for content delivery among content providers and end users over SUN based on content awareness functions and context awareness functions. Second, it covers the details about the
+
+functional architecture with several functional entities. Third, it provides the operations and informational flows among the functional entities to support the SUN content delivery functions.
+
+## 7 Features and capabilities for SUN content delivery
+
+SUN content delivery exploits the content-awareness [ITU-T Y.3044] and context-awareness [ITU-T Y.3043] capabilities of SUN to provide enhanced content delivery. The SUN content-awareness capability provides an ability to identify, retrieve and deliver contents efficiently based on the content-related information. The SUN context-awareness capability provides management and monitoring of context information and its changes for adaptive network operations. With these two capabilities, SUN content delivery provides four features: name-based content routing, in-network content caching, content delivery optimization and content routing adaptation.
+
+- Name-based content routing:
+ - Routing the content based on its name such as the content ID rather than its location
+ - Information about content (or metadata) can be used for content routing along with the content ID.
+- In-network content caching:
+ - Caching the requested content in the network to reduce transfer delay and duplication for delivering the same content from content sources
+ - The unit of caching can be a chunk of the whole content distributed over the network by an appropriate caching policy.
+- Content delivery optimization:
+ - Routing the content request by an end user according to the proximity, network status, resource condition and context information
+ - Cached content in the network can be reused for delivery at additional requests for the same content.
+- Dynamic content routing adaptive to context information:
+ - Dynamic changes of content routing paths or content storages (including content caches) according to the changes of the user and network context (e.g., network failure, network overload, use location, etc.).
+
+NOTE – The detailed use cases for context-aware content delivery are described in Appendix I.
+
+In order to provide these features, SUN content delivery functions provide four capabilities, as depicted in Figure 7-1. These capabilities are realized by distributed service nodes in SUN, which are capable of SUN content delivery functions.
+
+
+
+```
+
+graph LR
+ EU[End-users] -- "Content service provisioning" --> SUN((SUN))
+ CP[Content provider] -- "Content publication" --> SUN
+ subgraph SUN
+ CR[Content routing]
+ CC[Content caching]
+ end
+
+```
+
+Figure 7-1: Capabilities of SUN content delivery. The diagram shows End-users (mobile and laptop) on the left, a SUN cloud network in the center, and a Content provider on the right. An orange arrow labeled 'Content service provisioning' points from End-users to the SUN cloud. A blue arrow labeled 'Content publication' points from the Content provider to the SUN cloud. Inside the SUN cloud, there are server/router icons with a pink dashed arrow pointing to a magnifying glass icon labeled 'Content routing' and a green dashed arrow pointing to a document icon labeled 'Content caching'.
+
+**Figure 7-1 – Capabilities of SUN content delivery**
+
+- Content publication:
+
+Content publication capability handles the request of content providers for content registration to the network with detailed content information including the location of
+
+content sources. Based on this content information, it downloads the content from the content source to store the content in the storages of the network.
+
+- Content caching:
+Content caching capability distributes the content to the content caches of service nodes to optimize the content traffic by reducing the distances between the content sources and end users. The content is dynamically distributed to the multiple caches along the content routing paths.
+- Content service provisioning:
+Content service provisioning capability handles content requests from end users by selecting appropriate content with the given content ID according to the user context, and discovering the optimal content location that can transfer the content to the end user efficiently in terms of location and traffic optimization.
+- Content routing:
+Content routing capability discovers the content location based on the content locators determined by the content ID. The target content location fetches the content and transfers it to the requesting service nodes.
+
+## 8 Functional architecture
+
+The functional architecture of SUN content delivery is depicted in Figure 8-1.
+
+
+
+The diagram illustrates the functional architecture of SUN content delivery. It shows the interaction between End-users, Content provider, and the SUN content delivery functions. The SUN content delivery functions are divided into three main components: Content service coordination function, Content delivery control function, and Content delivery service function. The Content service coordination function includes Content publication FE and Content service FE. The Content delivery control function includes Service node optimization FE and Content name resolution FE. The Content delivery service function includes Content transport FE and Content routing and caching FE. The diagram shows the flow of content from the Content provider to the Content service coordination function, and from the Content service coordination function to the Content delivery control function, and finally to the Content delivery service function, which then delivers the content to the End-users. The diagram is labeled Y.3045(14)\_F8-1.
+
+Functional architecture of SUN content delivery diagram
+
+**Figure 8-1 – Functional architecture of SUN content delivery**
+
+The SUN content delivery consists of three different functions which provide the aforementioned capabilities by interacting with themselves as follows:
+
+- Content service coordination function (CSCF):
+It coordinates content services between content providers and end users to handle the content publications by content providers and the content requests by end users.
+- Content delivery control function (CDCF):
+It controls content delivery to support content name resolutions and content routing.
+- Content delivery service function (CDSF):
+It provides the actual delivery of the content from content storages or content caches to end users.
+
+While the details about CSCF and CDCF described in [ITU-T Y.3044] have different names of functional entities, their operations and interactions with the other relevant functions are fulfilled in this Recommendation by specifying corresponding functional entities and informational flows.
+
+### **8.1 Content service coordination function**
+
+The content service coordination function (CSCF) takes a role of a gateway between the network and end users, and between the network and content providers. When a content provider requests content publication, CSCF registers and maintains the content information. CSCF further initiates to further download the content from the content sources and register it with publication information by CDSF and CDCF, respectively. When an end user requests content, CSCF redirects the request to the optimal service node that is determined by CDCF.
+
+The functional entities of CSCF and their detailed operations are as follows.
+
+- Content publication functional entity (CP-FE):
+ - Handles publication requests from content providers
+ - Generates a content ID for content published by content provider
+ - Maintains content publication information.
+- Content service FE (CS-FE):
+ - Handles content requests from end users
+ - Redirects content request to CT-FE instance in the selected service node.
+
+NOTE – It can be provided by different redirection mechanisms, such as HTTP redirection or DNS-based routing mechanisms.
+
+### **8.2 Content delivery control function**
+
+The content delivery control function (CDCF) manages the information of network resources (i.e., service nodes), which hold the content in their local storages or caches to provide content location information according to the given content ID. Based on this information, CDCF also determines the optimal service nodes for content publications and content services.
+
+The functional entities for CDCF and their detailed operations are as follows.
+
+- Service node optimization functional entity (SO-FE):
+ - Determines the optimal service node to which content is published
+ - Determines the optimal service node by which a content request is handled
+ - Evaluates service nodes based on proximity, network topology and availability
+ - Maintains and monitors dynamic information (e.g., status, activity, performance, etc.) of service nodes.
+- Content name resolution functional entity (CN-FE):
+ - Manages (i.e., registers, deregisters and updates) the content ID with its content locators
+ - Resolves a content ID by mapping it to multiple content locators.
+
+### **8.3 Content delivery service function**
+
+The content delivery service function (CDSF) provides the content delivery from content providers to end users. Content delivery consists of several intermediate content delivery steps: (1) content download from content sources to content storages of service nodes, (2) content relaying and caching from content storages to content caches of intermediate service nodes along the content routing paths, and (3) content transport from content storages or caches to end users.
+
+The functional entities for CDSF and their detailed operations are as follows.
+
+- Content transport functional entity (CT-FE):
+ - Downloads the published content from content provider (or content source)
+ - Stores the downloaded content with its publication information
+ - Transports the content from content storages or caches to the end user.
+
+NOTE 1 – The content can be delivered to end users via different transport mechanisms, such as streaming or file downloading.
+- Content routing & caching functional entity (CR-FE):
+ - Discovers content locations (i.e., storages or caches) by interacting with CN-FE
+ - Fetches the content from the local content storage or cache
+ - Relays and caches the content received along content routing paths.
+
+NOTE 2 – It can cache the whole content or place/replace the chunk-based caches of the content.
+
+## 9 Content delivery operations
+
+Figure 9-1 identifies the operations of SUN content delivery functions. The operations are categorized according to their target uses in the SUN content delivery capabilities.
+
+
+
+Legend:
+
+- Content publication
+- Content service provisioning
+- Content routing
+- Content caching
+
+Y.3045(14)\_F9-1
+
+Figure 9-1: Overall operations of SUN content delivery functions. The diagram illustrates the interactions between various entities: End-user, Content provider, CSCF (containing CS-FE and CP-FE), CDCF (containing SO-FE and CN-FE), and CDSF (containing CT-FE and CR-FE). Operations are categorized by color: Content publication (orange), Content service provisioning (blue), Content routing (green), and Content caching (red). Key interactions include: Content request (blue dashed), Publication request (orange solid), Optimal service node query (blue dashed), Content register (orange dashed), Proximity query (green dashed), Content download (orange solid), Content transport (blue solid), Content publish (orange dashed), Content ID registration (orange solid), Content routing / forwarding query (green dashed), Content caching / forwarding (red solid), and Content finding (green solid).
+
+**Figure 9-1 – Overall operations of SUN content delivery functions**
+
+### 9.1 Content publications
+
+Content publication handles the requests of content providers for content registration to the service nodes with detailed content information including the location of content sources. Based on this content information, content delivery functions can discover the content which fits best to the user requirements and routes the content request to the content location (e.g., content source or local storages in the service node).
+
+- Publication request:
+Content provider requests CP-FE to publish their contents.
+- Content publish:
+CP-FE registers the content information and corresponding locations with CT-FE.
+- Content downloading:
+CT-FE downloads the content from the content provider.
+
+- Content register:
+CP-FE registers the downloaded content and its content ID with CN-FE.
+
+### **9.2 Content service provisioning**
+
+Content service provisioning handles content requests from end users based on the given content ID. It discovers the optimal content location which can transfer the content to the end user efficiently in terms of location and traffic optimization according to the user context.
+
+- Content request:
+End user sends a content request to CS-FE for routing and delivering the content from the service node.
+- Optimal service node query:
+CS-FE queries SO-FE to select the optimal service node in terms of performance of content delivery to the end user.
+- Content transport:
+CT-FE finally delivers the content segments or packets to the end user.
+
+### **9.3 Content routing**
+
+Content routing discovers the content location based on the content locators determined by the content ID. The target content location (i.e., service node) fetches the content and transfers it to the requesting service node.
+
+- Content finding:
+CR-FE discovers the content locations by routing the content request among the distributed CR-FE instances in service nodes.
+- Content routing/forwarding query:
+CR-FE queries SO-FE about the content location of the given content ID for locating appropriate content sources or caches.
+
+### **9.4 Content caching**
+
+Content caching distributes the content downloaded from the content source to the content caches in service nodes to optimize the content traffic by reducing the distance between the content source and end users.
+
+- Content caching and forwarding:
+CR-FE forwards or relays the content from a service node to another service node and caches the content.
+
+## **10 Informational flows**
+
+This clause provides the informational flows that complement the operations described in the previous clause.
+
+### **10.1 Content publication**
+
+Figure 10-1 shows the informational flow for content publication where content providers request SUN to publish their contents.
+
+
+
+```
+
+sequenceDiagram
+ participant CP as Content provider
+ participant CPFE as CP-FE
+ participant CNFE as CN-FE
+ participant SOFE as SO-FE
+ participant CTFE as CT-FE
+ participant CRFE as CR-FE
+
+ CP->>CPFE: 1. Publication request
+ activate CPFE
+ CPFE->>CPFE: 2. Generate content ID
+ CPFE->>CNFE: 3. Content registration request
+ activate CNFE
+ CNFE->>SOFE: 4. Publication service node selection request
+ activate SOFE
+ SOFE->>SOFE: 5. Select optimal service node for the published content
+ SOFE->>CNFE: 6. Publication service node selection response
+ deactivate SOFE
+ CNFE->>CPFE: 7. Update mapping table (content ID :: content locator)
+ deactivate CNFE
+ CNFE->>CPFE: 8. Content registration response
+ CPFE->>CTFE: 9. Content publish request
+ activate CTFE
+ CPFE->>CP: 10. Content downloading request
+ CP->>CTFE: 11. Content downloading response
+ deactivate CP
+ CTFE->>CRFE: 12. Content ID local registration request
+ activate CRFE
+ CRFE->>CTFE: 13. Content ID local registration response
+ deactivate CRFE
+ CTFE->>CPFE: 14. Content publish response
+ deactivate CTFE
+ CPFE->>CP: 15. Publication response
+ deactivate CPFE
+
+```
+
+Y.3045(14)\_F10-1
+
+Sequence diagram showing the informational flow for content publication between Content provider, CP-FE, CN-FE, SO-FE, CT-FE, and CR-FE.
+
+**Figure 10-1 – Informational flow for content publication**
+
+1. The content provider requests CP-FE to publish its content. The content provider presents content information (e.g., URL and metadata) for content publication.
+2. CP-FE generates an unique name (i.e., the content ID) for the content.
+3. CP-FE requests CN-FE to register the content. CP-FE provides the generated name, URL and metadata for the content registration.
+4. CN-FE queries SO-FE for the optimal service node where the content will be published.
+5. SO-FE selects the optimal service node for publishing the content.
+6. SO-FE notifies the locator of the determined optimal service node.
+7. With the generated content name and notified locator, CN-FE updates a mapping table listing the locators associated with content names.
+8. CN-FE responds to CP-FE with the locator of the optimal publication service node.
+9. CP-FE makes a request for publishing content at CT-FE. CP-FE provides the content name and URL to CT-FE.
+10. With the given URL, CT-FE tries to download the publishing content from the content provider.
+11. The content provider provides its published content to CT-FE.
+12. Once the content download is completed, CT-FE registers the content at CR-FE so that CR-FE can know the content availability.
+
+13. CR-FE registers the downloaded content and responds to CT-FE with the result of local registration.
+14. CT-FE responds to CP-FE with the result of content publication.
+15. CP-FE responds to the content provider with the result of the publication request.
+
+### 10.2 Content service provisioning
+
+Figure 10-2 shows the informational flow for content service provisioning after a user's content request was redirected to CS-FE. Note that "\*-FE (R)" and "\*-FE (L)" indicate "remote \*-FE instance" and "local \*-FE instance", respectively.
+
+
+
+```
+
+sequenceDiagram
+ participant End-user
+ participant CS-FE
+ participant SO-FE
+ participant CT-FE
+ participant CR-FE
+ participant CR_FE_R as CR-FE (R)
+
+ End-user->>CS-FE: 1. Content request
+ Note over CS-FE: 2. Derive user context and content ID based on given URL
+ CS-FE->>SO-FE: 3. Content service node selection request
+ Note over SO-FE: 4. Select best service node for the content service
+ SO-FE-->>CS-FE: 5. Content service node selection response
+ CS-FE-->>End-user: 6. Content request redirection
+ End-user->>CT-FE: 7. Content request
+ CT-FE->>CR-FE: 8. Content request
+ Note over CR-FE: 9(a). If the content is not available, content routing
+ CR-FE-->>CT-FE: 9(b). Content response
+ CT-FE-->>End-user: 10. Content response
+
+```
+
+Sequence diagram showing the informational flow for content service provisioning. The participants are End-user, CS-FE, SO-FE, CT-FE, CR-FE, and CR-FE (R). The flow is as follows: 1. End-user sends '1. Content request' to CS-FE. 2. CS-FE performs a self-action '2. Derive user context and content ID based on given URL'. 3. CS-FE sends '3. Content service node selection request' to SO-FE. 4. SO-FE performs a self-action '4. Select best service node for the content service'. 5. SO-FE sends '5. Content service node selection response' to CS-FE. 6. CS-FE sends '6. Content request redirection' to End-user. 7. End-user sends '7. Content request' to CT-FE. 8. CT-FE sends '8. Content request' to CR-FE. 9. CR-FE performs a self-action '9(a). If the content is not available, content routing'. 9(b). CR-FE sends '9(b). Content response' to CT-FE. 10. CT-FE sends '10. Content response' to End-user.
+
+Y.3045(14)\_F10-2
+
+**Figure 10-2 – Informational flow for content service provisioning**
+
+1. The end user requests content from CS-FE.
+2. Upon receiving the content request from the user, CS-FE derives the user context information such as user IP address, content URL and user device information. Also CS-FE derives the unique name of the content (i.e., the content ID) based on the content URL.
+3. With the derived user context information, CS-FE queries SO-FE for the optimal service node that provides the content to users.
+4. SO-FE selects the optimal service node for content service provisioning.
+5. SO-FE notifies CS-FE of the locator of the selected optimal service node.
+6. CS-FE requests the end user to redirect its content request toward the selected optimal service node.
+7. The end user requests content from the CT-FE that is running in the selected optimal service node. To identify the content, the user makes use of (e.g., the content ID).
+
+8. CT-FE requests content from CR-FE with the (e.g., the content ID).
+9. (a) If the requested content is not registered to the CR-FE in the selected optimal service node, CR-FE initiates a name-based content routing. (b) Otherwise, CR-FE responds with the content.
+10. CT-FE provides the content to the user.
+
+### 10.3 Content routing
+
+Figure 10-3 shows the informational flow for content routing to discover the content location.
+
+
+
+```
+
+sequenceDiagram
+ participant CNFE as CN-FE
+ participant CRFER as CR-FE (R)
+ participant CTFE as CT-FE
+ participant CRFEL as CR-FE (L)
+ participant CRFEUp as CR-FE (Up)
+
+ CRFER->>CTFE: 1(a). Content find
+ CTFE->>CRFEL: 1(b). Content request
+ CRFER->>CNFE: 2. Content routing query request
+ Note over CNFE: 3. Determining content locators with content ID
+ CNFE->>CRFEL: 4. Content routing query response
+ CRFEL->>CRFEUp: 5. Content find
+ CRFEUp->>CRFEL: 6(a). Content
+ Note over CRFEUp: 6(b). Querying content locator and requesting content from another upstream CR-FE
+
+```
+
+The diagram illustrates the informational flow for content routing. It involves five entities: CN-FE, CR-FE (R), CT-FE, CR-FE (L), and CR-FE (Up). The process begins with CR-FE (R) sending a 'Content find' request (1(a)) to CT-FE. CT-FE then sends a 'Content request' (1(b)) to CR-FE (L). CR-FE (R) sends a 'Content routing query request' (2) to CN-FE. CN-FE performs a local operation 'Determining content locators with content ID' (3) and responds with a 'Content routing query response' (4) to CR-FE (L). CR-FE (L) then sends a 'Content find' request (5) to CR-FE (Up). CR-FE (Up) responds with 'Content' (6(a)) to CR-FE (L). Finally, CR-FE (Up) performs a local operation 'Querying content locator and requesting content from another upstream CR-FE' (6(b)).
+
+Sequence diagram for content routing showing interactions between CN-FE, CR-FE (R), CT-FE, CR-FE (L), and CR-FE (Up).
+
+**Figure 10-3 – Informational flow for content routing**
+
+1. (a) Content routing operations are initiated when the local CR-FE does not store or cache content requested by the local CT-FE. (b) The local CT-FE requests the local CR-FE to find content (e.g., the content ID).
+2. If the local CR-FE does not know the location of the content, it queries CN-FE for the content locators with the (e.g., the content ID). The content locator is subject to be an IP address of the service node with additional forwarding information attached to it.
+3. Upon receiving the content locator query, CN-FE resolves the content locator's binding to the .
+4. CN-FE responds to the local CR-FE with the content locator.
+5. The local CR-FE sends a content request, using the content locator, to a remote CR-FE that is on the upstream path.
+6. (a) If the remote CR-FE stores or caches the requested content, it transfers the requested content to the local CR-FE. (b) Otherwise, the remote CR-FE requests content from another remote CR-FE.
+
+### 10.4 Content caching
+
+Figure 10-4 shows the informational flow for content caching.
+
+
+
+```
+
+sequenceDiagram
+ participant CT-FE
+ participant CR-FE_L as CR-FE (L)
+ participant CR-FE_R as CR-FE (R)
+ participant CR-FE_Up as CR-FE (Up)
+
+ CR-FE_Up->>CR-FE_R: 1. Content
+ Note over CR-FE_R: 2. Caching received content and updating cache list
+ CR-FE_R->>CR-FE_L: 3. Content
+ Note over CR-FE_L: 4. Caching received content and updating cache list
+ CR-FE_L->>CT-FE: 5. Content response
+
+```
+
+Y.3045(14)\_F10-4
+
+Sequence diagram showing the informational flow for content caching between CT-FE, CR-FE (L), CR-FE (R), and CR-FE (Up).
+
+**Figure 10-4 – Informational flow for content caching**
+
+1. The remote CR-FE receives the requested content from another remote CR-FE along the upstream path.
+2. The remote CR-FE caches the received content in its storage and updates its caching list that maintains records of cached content.
+3. The remote CR-FE forwards the received content to the local CR-FE that requested it.
+4. The local CR-FE caches the received content in its storage and updates the caching list that maintains records of cached content.
+5. The local CR-FE delivers the content response to the local CT-FE.
+
+## 11 Environmental considerations
+
+The SUN content delivery functions focus on the efficient content delivery by optimizing the traffic with content name-based routing and in-network caches. This capability can reduce the duplicated delivery of the same content and shorten the content delivery paths. Consequently, the reduced number of network elements for content delivery results in reducing the energy consumption of the network.
+
+## 12 Security considerations
+
+The SUN content delivery functions provide in-network storages and caches so that end users can directly retrieve the content from the intermediate service nodes in the network. In this case, the content provider cannot perform authentication, authorization and accounting (AAA) for the content delivery. Therefore, the SUN content delivery functions are required to provide additional security methods to perform AAA of end users on behalf of content providers.
+
+## 13 Accessibility considerations
+
+The SUN content delivery functions provide name-based content routing so that people with disabilities can utilize the content delivery more easily with human-readable content names rather than content location information such as IP addresses. The SUN content delivery functions also provide context-aware content delivery. Therefore, the content delivery functions can automatically adapt to the context changes, thus minimizing interruptions to people with disabilities.
+
+## Appendix I
+
+### Use cases for context-aware content delivery
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Context-aware content delivery can be the bridge between knowing the mobile user's current situation and delivering related content for that situation. It can be an ideal tool to deliver content in a useful and focused way for content providers. Fundamentally the process can be defined as collecting evidence of a context, matching it with other contexts in the context space, and searching and integrating the content, which is to be delivered. This is how the linking between context and content delivery should be done in order to put the content into context.
+
+This appendix describes a use case for context-aware content delivery that provides optimal selection of source and path based on the context information.
+
+End users request the content provider to deliver the content that is located at multiple and distributed content sources in the network. Then the content provider redirects the user request to the SUN nodes, which are capable of context-aware content routing function (i.e., context-aware router). The context-aware router manages the context information by collecting, analysing and retrieving information periodically or dynamically from context sources. The context-aware router can decide which content source is the optimal one based on a combination of context information. An example of context information for the use case is as follows.
+
+**Table I.1 – An example of context information for the use case**
+
+| Network context ranking | | Service context ranking | |
+|-------------------------|-------------------|-------------------------|------------------------------|
+| Ranking | Content source | Ranking | Content source |
+| 1 | Content source #1 | 1 | Content source #2 |
+| 2 | Content source #3 | ... | ... |
+| 3 | Content source #2 | 9 | Content source #1 (overload) |
+| ... | ... | 10 | Content source #3 (failure) |
+
+In terms of network context, content source #1 has the best proximity to the user because the IP address of content source #1 is "1.1.X.X". But, in terms of service context, the content-aware router excludes content source #1 because it is overloaded with too many sessions. Content source #3 has the second ranking in terms of network proximity; however, it is also excluded because the content-aware router finds a service failure on content source #3. Then, content-aware router decides that content source #2 has the optimal source and path to deliver the content to the user. Finally, the content-aware router redirects the user's request to content source #2, which will deliver the content.
+
+Figure I.1 shows a procedural flow for the aforementioned use cases for context-aware content delivery.
+
+
+
+```
+
+sequenceDiagram
+ participant User as User (1.1.2.1)
+ participant CP as Content provider
+ participant CAR as Context-aware router
+ participant Net as Network
+ participant CS1 as Content source #1 (1.1.X.X)
+ participant CS2 as Content source #2 (1.2.1.X)
+ participant CS3 as Content source #3 (1.2.2.X)
+
+ Note over Net, CAR: Network context (routing information)
+ Note over CS1, CAR: Resource and service context (cached list, load ratio, etc.)
+ Note over CS2, CAR: Resource and service context
+ Note over CS3, CAR: Resource and service context
+
+ rect rgb(240, 240, 240)
+ Note right of CAR: 0. Analyse context information
+ end
+
+ Note over CS1: Overload
+ Note over CS3: Failure
+
+ User->>CP: 1. Request content
+ CP->>User: 2. Redirect to content source
+ User->>CAR: 3. Content request
+ CAR->>CAR: 4. Extracting device context
+ CAR->>CAR: 5. Select optimal content source based on context
+ CAR->>User: 6. Redirect to "Content Source #2"
+ User->>CS2: 7. Content request (ContentID)
+ CS2->>User: 8. Deliver content
+
+```
+
+Y.3045(14)\_F1.1
+
+Sequence diagram illustrating the use cases of context-aware content delivery. The diagram shows interactions between a User (IP 1.1.2.1), Content provider, Context-aware router, Network, Content source #1 (IP 1.1.X.X), Content source #2 (IP 1.2.1.X), and Content source #3 (IP 1.2.2.X). The process starts with a content request from the user to the provider, which is then redirected to the context-aware router. The router analyzes network and service contexts, including routing information and cached lists, to select an optimal content source. Due to an overload at Content source #1 and a failure at Content source #3, the router redirects the request to Content source #2. Finally, the content is delivered to the user.
+
+**Figure I.1 – Use cases of context aware content delivery**
+
+####
+
+1. Context-aware router collects the network context from the network by capturing dynamically changing routing information.
+2. Context-aware router collects the service context from the content source by collecting periodically or dynamically changing service status such as a list of caches, load ratio, number of sessions, average service time, etc.
+3. Context-aware router periodically or dynamically analyses the aggregated context information and summarizes the context information in the abstract format such as ranking.
+4. Content source #1 is experiencing overload because of too many service sessions.
+5. Content source #3 accidently encounters service failure.
+
+####
+
+1. The end user sends a content request to the content provider.
+2. Content provider redirects the content request to the content source using HTTP redirection or DNS-based routing mechanisms, for example.
+3. Content request is redirected to the context-aware router.
+4. Context-aware router extracts the device context, if it exists, from the content request.
+5. Context-aware router selects the optimal content source based on the contexts and policies for determining content delivery paths. For example, if the network context has a high priority, content source #1 could be selected as the optimal source. But, in this example, content source #2 is selected because the context-aware router has a policy to consider both network and service context. In terms of service context, content source #3 is excluded because it does not have enough resources to deliver the content.
+- 6-7. Content request is redirected to content source #2.
+8. Content source #2 delivers the content requested.
+
+## **Bibliography**
+
+- [b-ITU-T Y.2002] Recommendation ITU-T Y.2002 (2009), *Overview of ubiquitous networking and of its support in NGN*.
+- [b-ITU-T Y.2201] Recommendation ITU-T Y.2201 (2009), *Requirements and capabilities for ITU-T NGN*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6037e4bfbe8505d9b99497e40a2a547bc6aa83f5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:00727abd468de397e682adb9499bc3eaad7f91644d741235996b18cb0179d4bd
+size 133041
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e54375ac9c93adfbc699875cb6ab4edc33735fd9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:139aa0ab9ebecdf518d51a0cdf5cb5b687dcfe76b8305be74eb43ff46bc7c798
+size 64468
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8423857338c7943fb53f6d62820e1de9b67a04e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:da9f8de1f3eacbe3b5a5a51aa159e69515d35956d070ed38c2839f2d3b43bc36
+size 4216
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..874400c50f17fecac61088955789e924a925ea3c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5db0c56068cd2a2d62a9e827f67b11ca08ea45160513df8727d1c0821c1e3bb5
+size 57476
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0ae37ca73ed4099f4de9c5ce17144ac5bba8530c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f61c422e4e77b9ebb14be6d933db3113a0975a3b8f8bc9024f4c6200a451adaa
+size 22343
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..bfc859e4d53ca7509638e3fcca5fa246230cbedb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a5040010f6480d2857e3de06596a36fa5159da54ea9407fe04420cd91ffbb5bd
+size 73058
diff --git a/marked/Y/T-REC-Y.3053-201801-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2cbeedc6ab1f0884896ec227eca79e105c866adb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3053-201801-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3acb796d2014779af9f8bc2d4015bf73a922c61885aec4341cc9283f37d4cbd4
+size 64184
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2339461b51903bde00e1579d5ae5e6aa93033e82
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4012d33f427c217a8d339480e8ce84f6ead8746a6903ac01c84f1ec6b62c6104
+size 77397
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..71e8f3aed3aedaabea3dedfc4ad570b0908669c1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2a603243582b57cfca307e40f086c4656f297a449f861cc16658d73e2b2ae477
+size 125584
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..823c773f910a3ade82b7b5ead907d09d27a678b8
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/4f148853ae68fdcf5e43f7604cab457d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:385d2d259d19a870ac7f0b2d7b79ce388be4ca916ededab5f8c3b592cd75eff1
+size 72212
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..da9729fc7f03a83c273c8807b2d1b9a3478222a0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b79dd60708207f3a9da0d34bfe41317ebb676de6b03d7e7bab2abc1ac43fa92a
+size 100898
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..eb11ac0e059f049265a44e94564503f19978a877
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7a32837bde322e7b364c602828cf179f3224e911c2d830eaf5009a6880ad36d2
+size 92890
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..27c391195d8e9ec573ea83bb2cba41424b010767
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5ab276f8eebba5182212734079c7222c009691946a1db201679dba981681f6c6
+size 159608
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1171e4367afffe1dc419450738341bf109161e7a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6dc4e10c034bea218d2805eed6248e0a36582dd1663f4a59a91f478b03d31b08
+size 6923
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f3eed504e85ca6b0ff7e66a91bc79d265cfd28e5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6de22033b3cae1abb21d5558a6a7e05d45d5a5dd76391324f6979c093b48b93e
+size 148624
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4abb591975ee6434a8394bdbaa8cfea9fb6f8b65
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6cfd73e911ef2093023811f211ea43a72c5ca3a2bf6ce97ab1a8f49cf5f8abc0
+size 122375
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/a3472689858b068ef469213682965325_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/a3472689858b068ef469213682965325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b91a2fe8dd89d78f1ea3be4bad518e2c832f9a7d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/a3472689858b068ef469213682965325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b0017acb4732b696a1fd9b0b6f20ebd6a6f3c11e51aba86386b5b49f91f586f7
+size 121370
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/af6be343f0c0a8f155f965dcf337b8af_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/af6be343f0c0a8f155f965dcf337b8af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..685b8eba8dccb380335d50a2973bda82f8925c0b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/af6be343f0c0a8f155f965dcf337b8af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:14b7ad0274db9e1639fa150b80fc39bc34eca4a398f8f0aeefbbf83dd09c4ab9
+size 144933
diff --git a/marked/Y/T-REC-Y.3055-202009-I_PDF-E/c9bbd160a32f2fdbd7a819d382ac49b6_img.jpg b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/c9bbd160a32f2fdbd7a819d382ac49b6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ea8a5d7c89bc796c366760c453cb15bfeb0feff5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3055-202009-I_PDF-E/c9bbd160a32f2fdbd7a819d382ac49b6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1b8e1af1911a49934c89b1106ffae6df32adc2b85ed6246da20aa7ddbd7cc863
+size 108023
diff --git a/marked/Y/T-REC-Y.3060-202309-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg b/marked/Y/T-REC-Y.3060-202309-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..93380f614fb80727e79415015e85c5cf49f7ee88
--- /dev/null
+++ b/marked/Y/T-REC-Y.3060-202309-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e1c507ea63febb8f726a2cc3aae7b73b2e611cc89cb238dcbe073642e2f30355
+size 110769
diff --git a/marked/Y/T-REC-Y.3060-202309-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg b/marked/Y/T-REC-Y.3060-202309-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3060-202309-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3063-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3063-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3063-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3063-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3063-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..426d75c9d7dc54f2e8d1a56f86a954561dbe5704
--- /dev/null
+++ b/marked/Y/T-REC-Y.3063-202512-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:58058a92da52a6d3ae58a25e300662de8055ae04e6073974feeee618c928704e
+size 48774
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/29f586959675cafdf81cf934954908eb_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/29f586959675cafdf81cf934954908eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..61137f0313cc2939f4c390554ae7f24dd4e49719
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/29f586959675cafdf81cf934954908eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1fb7886c24e6f9a9c8117505150bc1451b2629e2dee1214aeed8039e997a796c
+size 25683
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/552265bdbcf6d43d341fd018a9076269_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/552265bdbcf6d43d341fd018a9076269_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1117a397f12f657a9e4aad316fd3c0af71107634
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/552265bdbcf6d43d341fd018a9076269_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a497a384764ee439b103f3767e96bc73332b8ca38ed22f646129767180ebf063
+size 65096
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2f9dc10d2498896ada850c9f9bbad7ea79fa4f2b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/7d3d5fb5d09c0cd35a9d637be241651e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3ecaf395f0f8eede044f4a5f222cbb14e34d0517e6269612185967411902bc94
+size 57477
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f4afe5ab687c9a9b26b059abfea6b07fac7bca2d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:487f752796043fe6e62b21f09557c6ded31d4382fa88e33601649a7f5965f78a
+size 115846
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4e5730f32247d57c9eb0c81598ec9d5f6b428b20
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4507be013476a0a8daf631058ac30d005020dd73f574df54f649d300eb1b5d7e
+size 80177
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3c92d8895389b167c2c86bf702012005d9502861
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:18285d9481c2e4fe650df0258b55ec17632243c7e1c8c71df70213c346429b75
+size 9717
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..420db6d2cfb4ff1bce7fff87e6af54d71be5bf20
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:893e5914371d0ab7646e74825704c72bffe5267e47ded63e780694761cb3d69a
+size 163002
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..70676166132801ed53e9bfee9126dac8de0faa2f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:82404c476390558c5378f81bcdae854c754b6a356c70784ba6ebb4ad3d7de0e9
+size 87554
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4d6cea6eec05195435dab02c83885b081c995465
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c5452f95f3b28f1bfe29e84fbc2e1267_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:986caaa0ae71a53acc47b4b3c1a8fec2e9e514036e8e65714043a8ac83758e71
+size 113088
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..71e1537fcf7d62ceeb4ca06bdee15c71c220a056
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2ef2b1f6746b504f41c4ff92c1f7276cf8ebbd8926e720f28b31c7e4de49b71d
+size 65457
diff --git a/marked/Y/T-REC-Y.3064-202512-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..38bdb0a2d7ec8eed6b73876069fbf9e8ed201650
--- /dev/null
+++ b/marked/Y/T-REC-Y.3064-202512-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:537f68779301cc5f079a0f41c188e0db8f5e86bf0d5dea63a14983036edc0dda
+size 5055
diff --git a/marked/Y/T-REC-Y.3079-202209-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fec989489ff96ff527a9b69c0336e00d43c0b2c4
--- /dev/null
+++ b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:80b0f7beed1d20287d4322a636f98661b396158ec0d02876f862e2b87b8b5168
+size 129933
diff --git a/marked/Y/T-REC-Y.3079-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94d45ee0d7450a0c276bffad33306ce1ec96de62
--- /dev/null
+++ b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c981deef08fa0ff69264e0a06c61f5dd291a362fb37303b3216e33a0ba5040e9
+size 5841
diff --git a/marked/Y/T-REC-Y.3079-202209-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..91092d59a480b9846e98dcffd5fdfc802f013157
--- /dev/null
+++ b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c38e53ea99323328f0df2f38cf88e5a25cb3f6d73b713325ebe321ecdb132e77
+size 25682
diff --git a/marked/Y/T-REC-Y.3079-202209-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e4fa1f2a7bfb375898375849f4bcb9e88c12a759
--- /dev/null
+++ b/marked/Y/T-REC-Y.3079-202209-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0ca41f1410336bb9563181cf9b7d6862d7908738e6141bf5d486652e5cc81989
+size 76761
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9eab3e874f7bec5e1e4f830ab039ef988f102d1b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/007b053fe94a8348f75128a584503fd0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fe768065a933d3b0e91dcff5ab604162c18b10a0deafafc1236ae62cc644a52c
+size 33756
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/19a59d6b53059ebd27b13c98793f88e0_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/19a59d6b53059ebd27b13c98793f88e0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..642b099f6248cd2cbb013d381b736cd52f0294ce
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/19a59d6b53059ebd27b13c98793f88e0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f0af00c8956d68cc2f81d447e66c74252ac5717d42bbfbf67f2e8cb8cc1f8f60
+size 42376
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..28bf55e41a2a0619b120faafb10a5aca5d269cb2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:73a848cdf9c4402fbb9f5c76c001e41e1cf7c0171f4937acd175be2b0db216ed
+size 5897
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7efdb4d8baefdebb66e71fe703492b644692c5c6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/26d664119ad25250780f554633444e54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f781a36c757a3a480202e1a3150d79d7f8f745aeddb4943349fadd7358a15a20
+size 43192
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d50f59d175aa2c0675433da6b58da84a92d901df
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a041ac269cb66570f7dc07a3843b57c00b83483ffa9d949ef8870c509b8fe9f2
+size 76694
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..06b0a92efe9ad147fbdba48f3c57be841eaac2c9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:35699e759c6bf6ca564f125ed021a5c6e755186b7c75641b9de057ce2794e735
+size 32942
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e18cc5b05a9758525ddcc61d7714744b40aa2fd9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/7e1c9b51e067a48cd0fcc9748d8bd8d8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:de6ea50ce9764bc02afc892ea23282ebbf8c36437c496d8d8a3bc63c055241b7
+size 32539
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f62b35ad121e9c7def97efc3e40e43a33362c656
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6c52204feb9bfcc899e93f2edd2fc5aefce374570b88b126a4eab1713a1daafe
+size 44241
diff --git a/marked/Y/T-REC-Y.3081-202209-I_PDF-E/fb8e5a145979457197c6b0f78b8128ff_img.jpg b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/fb8e5a145979457197c6b0f78b8128ff_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..35f185b380e85756cfa48f82f854b00269ebd885
--- /dev/null
+++ b/marked/Y/T-REC-Y.3081-202209-I_PDF-E/fb8e5a145979457197c6b0f78b8128ff_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a1a726c32385d481e4b615c6d55116326d0f42742da3da0dd025c38c0a1c9277
+size 26317
diff --git a/marked/Y/T-REC-Y.3092-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3092-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d0280a66f813b6ed2bc9fc6dd0cee07dacaaf5a4
--- /dev/null
+++ b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:78115e17ece4808958219b4231dd284338481d9006334c0fc1c5d729f598a83d
+size 21984
diff --git a/marked/Y/T-REC-Y.3092-202409-I_PDF-E/410562339ce067fdc6fa41940c118658_img.jpg b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/410562339ce067fdc6fa41940c118658_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..59bdf5b60ceea0b88eec494213c1116e590567b1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3092-202409-I_PDF-E/410562339ce067fdc6fa41940c118658_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d09bf38013747f512ef02c1dec89ec8cb7247aca24414c20d53b5aff72047513
+size 75580
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ea830158d99c8840afa9c2a83c859c198f404f14
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2d03fd94d6b9e52d9780d2e93d71b36bb3d70a0a3a35d69fcf241bfacd799997
+size 114730
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4f2cb7a529d6613d67120c24fb2cb1452858a435
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2c9b7b18abc74122045766d61821af23146bd727c67f0a51af7f5dc1dd1a8e76
+size 6840
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6e8a60517a05277fc6c11e777b23d50cce1bb129
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/27b06ec9f42b5d727a2630f61a5f1861_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:841be4d173e4f3eeabec57c81ba51d3f25874b12c5335a190cde01112f82e020
+size 95056
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1d072d677db3addf734cd1632586c5ec4a136f2b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dac610eb35ec52da543696ae04fdd0358e1477983c557aefcb33c2774493b266
+size 55529
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/43979979715bb3304389a0cb18f34444_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/43979979715bb3304389a0cb18f34444_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e7ab2886396c34b06f0b26c84824d61584b540f9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/43979979715bb3304389a0cb18f34444_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c7fe81a8882fbe706900b14adcfb3651a99131843e5ce3fed90872a386d9af7a
+size 10620
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/5dca16cd6224cb81fefbd38274e5eb80_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/5dca16cd6224cb81fefbd38274e5eb80_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3384676b510eafe115f349602d24a85055d068ca
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/5dca16cd6224cb81fefbd38274e5eb80_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:347b96e9a3987d514c6f605be42ab86f07a8d803677f920a4b1ceebd33d54fae
+size 9911
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/63a2519518616620ef0e53d98b923c05_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/63a2519518616620ef0e53d98b923c05_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d81ae3b8739a1bcebadf821bb36909103a9fee42
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/63a2519518616620ef0e53d98b923c05_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7955899a675fe560ed3b7be4abd9a25b9abd69ad2143d74e08431e86ab4f7a62
+size 15049
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b298748effceed75dd10f4cf43a149e0095de802
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e1b9621688b0e17cdb2d082ba5aaa826e2cc7db645e2f746983d996ac56adc3c
+size 32158
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1949e509d5c7bd70e5828e0e25ff481b34606bae
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/77959075c823bb5169480d7b8ff82a63_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d9508da3592d4f831d19818ad505188636f179ce0ce2672856be8d682083f940
+size 128541
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d511683b60715f20c3f504a218f35a29ad8a4fab
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:762d778139d2cbbee453ab14dd4a9055e7ab70441159886a91cac5a64d5852d3
+size 57671
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d30992cf6b35a33f36df82f12bbc89a11c8132b5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e0fcba877fd568be5b02427109037af36acbcd988c6fa9a39efb07e78ab0e2e1
+size 25599
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d9e7321316b2f74d375b97547af22287f8c5f800
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3b3f2956da81ac54f9b0a48e1384f5c6981dbb7a94f55ec9bbca6100dc8eda05
+size 62209
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3d6a8d94f26f5ce3142c2a8bf0d892a0ef44380b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f8741673382d5363ccd91bbda77abc4e2b25024c26d2f0bb8725257a88a31dd2
+size 78028
diff --git a/marked/Y/T-REC-Y.3111-201709-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1bc9dc46e8e933313b0eb21a31e49c63340a2a49
--- /dev/null
+++ b/marked/Y/T-REC-Y.3111-201709-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6ca2ccf1a6d3d3f1700c69fb4b576ab7e0efb61343a508eaa80a13b6e05c072c
+size 71295
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..27033a4cf96809d11f6b2371db876b36e16b1028
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9b538775df14b8ffe82a3e00030a295c914769c04d9b4d00555e569e6787d305
+size 59759
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b2ac98ec2cf5123705884afad81d00e15f086010
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8fe458bdb2f8f97cbf2e74f80ba629337ba249d1ea6c1b8db1379b85aea3e254
+size 5883
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3405b24de10a29a3a238bc44bda0a88e4f7fcc93
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3500e2afa77d9bd8fa7134f0c64e780591266ce7d4ce1db892eab5511eb706e7
+size 45780
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7a513c8c74fbc042aafb05d9f623a654551c1005
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/81a4cbf0b3c4cbc065efdf8f800dadde_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:83c99e6b9e1f0881f82e30037699e8977e06da9fd588a3a78294bea4f35303c5
+size 66635
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..56f8bf3b9cd47fde5b50e24f301d12d69e085982
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee607ac08058a814a5d58f84e0013b011beb77541762211c30ffb13bffea83c5
+size 50167
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/98ee20ceb85cd84e2415b20b1eda1bcf_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/98ee20ceb85cd84e2415b20b1eda1bcf_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..facc8ae3fb562c06a061e3242ff839c17df8a5ee
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/98ee20ceb85cd84e2415b20b1eda1bcf_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a8935117a5ef55df7b0ca2a0cba817f8d550c38cc9e88a8ed06ae1b4b8f626b5
+size 89047
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9fb980f37d38a27b42e45c3095add0d4893fe684
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/d734a6ea1b381280f043fcf70391b6db_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5eef96532defec3b28ebb7dff8cbc244fbff3929f1a884731eeb9bf9e50963fa
+size 44677
diff --git a/marked/Y/T-REC-Y.3114-202202-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..be0b357ee5b2de91c2d630875457ee7481a27f55
--- /dev/null
+++ b/marked/Y/T-REC-Y.3114-202202-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bb4dd69676397e07ab7814ff122850c62e48f479faa7330e55b38b97c72ddb8f
+size 53243
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..072f073b6d42cbfa77c827c76c611f286177034a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee72ddf991b7b1d543b2694b1687804845ecb97da77cc35e98e4c7dbf5ac163d
+size 4142
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0862f0b754ccd336627ac2cdba756f9545a72138
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a39e983e1aa5bd7dec43d1b740aebe4ce15a1b5fbb58977124f0abc3ad22e4aa
+size 60656
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f7009cce786758cf6041b9cd68e441519487611a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:511efc2fae6ca3c52c3b7fcad2c8134a337c2dcd3999e21a846c68e4def6ea01
+size 51839
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..53d88107634c97c1e4db4c2abe6a835e0797c903
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4ff4ab1b196130b36d2c0f8ca6e7fb83b56998e76fe66eef70713403aaafd47b
+size 50931
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..211eea4b0db289a34e1cb6d98988f05a11534f5a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a1956bba11d27cfe1bbf029c865454d8a23e8bc36384d4ba4f11c1e1f5335dff
+size 51224
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..325e83fc0cf0587993203e0cef19fd49d318e47f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1268c2ac3f7c1040a8410afb7bb120e3db76b113a792309b6ee088bf1d64439d
+size 62156
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..406dc2bc3c1392dd855261f82f4c33374085298d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dbd1b83e92ecda039fbb229294702773f84914b97272eed6ad756d5be72e1a36
+size 59441
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..364ab3d3bf111cc9750ee6da802f87bd10c140ec
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e3a32515092a7ce6a092995ca78bf42d94a2e7767189eeea5af593a44a4a9c3f
+size 68261
diff --git a/marked/Y/T-REC-Y.3133-201912-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..506338724480c3e3acd8887a74ae5d5c8c3a60ea
--- /dev/null
+++ b/marked/Y/T-REC-Y.3133-201912-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7dbcf36dcb5991fe0d8829bbbf69a40c2ec6109a28f427d95739b4ed8bdf1b7a
+size 99344
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4410e56e3391891d8ed50b82fe209007373718a0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/08441fa90c5fd11994626f662ac13f19_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4b9018bf9aa9b21a8f72d2d5e96f19c8ba00706e87753424edc6baf7f2bb9a1e
+size 39861
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/16152cf1d84aea10848758f51a91ff6a_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/16152cf1d84aea10848758f51a91ff6a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3b6d72b8c01305faf7992efa0595391ac8cd244b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/16152cf1d84aea10848758f51a91ff6a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:978b5886d40edd96f8b2f8cddee7877a03cee9ddbb881700f48a87975cc251ec
+size 44779
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..891a1051d69050132bdf65a8fca91921fc34862d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cccb03838170d58751d24ab8074ffcd288f44c30858470110715df6ca9e7c32e
+size 20833
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..050f1f5dbd255d81ea73019e0f0eef11f7412f4e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7922df6a6a56855f1c8dd7fa3d02456b11cc35d8b34ddfb4d1e04686ba9e7720
+size 136755
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/6f341f415ee0f8c724e5d6daeb1e9b4a_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/6f341f415ee0f8c724e5d6daeb1e9b4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5663f053bb383b080e19a5041bab64c53731bb1d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/6f341f415ee0f8c724e5d6daeb1e9b4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8b22a47ca192dcc2a012f99a2745034b1070f444e5c04d789571a4e9bbcb6490
+size 51311
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2dc42999c1a9157e3e91aad2e338783b738879bc
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b680ec95ac63f1f9892561ce908c9a74d9d8d84e8f76250367cc16a524502e0c
+size 81520
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..00c0b34f6e8abc925e851fb2eb18f7fe4252e757
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a1913bbed4fc7b631dd4b3b3f859282d32f6be6e48379a015a1eea3b42898206
+size 86963
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..af7a0edee5a28ae92868a68e1f3edf7f3199480c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:09ca31a3f1ad0b54663b43fd758e605e3a5fff8ee2d0316cc73f64638d4470a7
+size 19973
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a216b1004faad76d847102ee02603f881954c794
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:34f41293d521e54479b0b80fabeead265f79f93b82ffc28ffcdbe32d383d85d1
+size 55573
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c6a5302e558ab6d15db015649b53af431358359b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:03db1ca3cfff80a1d5d5e50957c7acb4cfed263757e9511e437fc2bd0dbc8ced
+size 79079
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9ad691967e4dfc3f012e626a4be62fab5451f837
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a99143c511fcaadbd8a3cdaa119f837beb587a21a678d94266ce90593b801d88
+size 98514
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..31890ba9d2a47b9885d161440e1d053d257b9195
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/b6671cfafda3820aafe9a24fa7a4d8c7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3d34b81d48889d7fc7f24931091466f13d9d8dc4c1f5a638ddc7607b4db8896e
+size 47508
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0fc653423ffe828e7adf61a42942f7fd5c9e3f1a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a5c05d2c12c7824f5eda0a66b91ecd54aab48e62609b9838f69e1d569926e6ce
+size 28425
diff --git a/marked/Y/T-REC-Y.3145-202504-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2b591ac14142a69fb5cd3da9fe37b5c13052b27f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3145-202504-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1379f2ecbfefc40e5d48f668bbea47e4cd1597359a81f92082c9dcc2e9f47280
+size 23810
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..21253f8036c666566702cf50a6797c17f957f93a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b66a222e6cdcb11b68ea4753946a59b2f60f0f94ea8483988c51fb6f76714700
+size 31121
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..65665bdf7e327767b08ff4dade32647efa938b71
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1486efa19a8064916125f0566a71af36fd9ab785a74cad8b239301b068099422
+size 37199
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ca853caf665e7c765c3fb57a489836522d15b7e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e306b5f4f9b579a2854f0a93b06616227be54406b559980e3efe26560e0c28f0
+size 52923
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5d3fa5b0942bfc3b1c8dc07ff11ba4b62e74ddad
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1d37fc3b1e1e4ac5315a469f923f054cab3d700e15940b79a70ae30480b83539
+size 104014
diff --git a/marked/Y/T-REC-Y.3156-202009-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..7781ba414837ac09a87c9ecc9f0a92ab84ef0bd7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3156-202009-I_PDF-E/raw.md
@@ -0,0 +1,570 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.3156
+
+(09/2020)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Future networks
+
+# --- **Framework of network slicing with AI-assisted analysis in IMT-2020 networks**
+
+Recommendation ITU-T Y.3156
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3599 |
+| BIG DATA | Y.3600–Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800–Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | |
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+For further details, please refer to the list of ITU-T Recommendations.
+
+## Recommendation ITU-T Y.3156
+
+# Framework of network slicing with AI-assisted analysis in IMT-2020 networks
+
+## Summary
+
+Recommendation ITU-T Y.3156 describes the requirements and functional roles of AI-assisted analysis in support of the lifecycle management and orchestration of network slicing. It is intended to be used for the future enhanced operation and maintenance management of network slicing with the purpose of satisfying users' service level agreement (SLA) requirements.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3156 | 2020-09-29 | 13 | 11.1002/1000/14401 |
+
+## Keywords
+
+AI-assisted analysis, IMT-2020, management and orchestration, network slice.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2020
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|----------------------------------------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 3 |
+| 5 Conventions ..... | 3 |
+| 6 Introduction of network slicing with AI-assisted analysis in IMT-2020 networks ..... | 3 |
+| 6.1 Overview ..... | 3 |
+| 6.2 AI-assisted analysis for network slice lifecycle management..... | 4 |
+| 7 Requirements of AI-assisted analysis for network slicing in IMT-2020 networks ..... | 5 |
+| 7.1 General requirements..... | 5 |
+| 7.2 Requirements for customer support..... | 5 |
+| 7.3 Requirements for network slice preparation..... | 6 |
+| 7.4 Requirements for automation of runtime management..... | 6 |
+| 7.5 Requirements for Inter/Intra-slice OAM ..... | 7 |
+| 8 High-level framework of AI-assisted analysis for network slicing..... | 8 |
+| 8.1 Functional description of AI-assisted analysis ..... | 8 |
+| 8.2 Relations with automated slice M&O ..... | 9 |
+| 9 Security consideration ..... | 11 |
+| Bibliography..... | 12 |
+
+
+
+## Recommendation ITU-T Y.3156
+
+# Framework of network slicing with AI-assisted analysis in IMT-2020 networks
+
+# 1 Scope
+
+This Recommendation describes the framework for the AI-assisted analysis of network slicing in IMT-2020 networks. The Recommendation supports the whole lifecycle management and orchestration of a network slice. This Recommendation includes:
+
+- Requirements of AI-assisted analysis;
+- General functional roles of AI-assisted analysis;
+- Relations with network slice management and orchestration.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.3111] Recommendation ITU-T Y.3111 (2017), *IMT-2020 network management and orchestration framework*.
+- [ITU-T Y.3150] Recommendation ITU-T Y.3150 (2019), *High-level technical characteristics of network softwarization for IMT-2020*.
+- [ITU-T Y.3153] Recommendation ITU-T Y.3153 (2019), *Network slice orchestration and management for providing network services to 3rd party in the IMT-2020 network*.
+- [ITU-T Y.3154] Recommendation ITU-T Y.3154 (2019), *Resource pooling for scalable network slice service management and orchestration in the IMT-2020 network*.
+- [ITU-T Y.3170] Recommendation ITU-T Y.3170 (2018), *Requirements for machine learning-based quality of service assurance for the IMT-2020 network*.
+- [ITU-T Y.3172] Recommendation ITU-T Y.3172 (2019), *Architectural framework for machine learning in future networks including IMT-2020*.
+- [ITU-T Y.3324] Recommendation ITU-T Y.3324 (2018), *Requirements and architectural framework for autonomic management and control of IMT-2020 networks*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 network slice** [b-ITU-T Y.3100]: A logical network that provides specific network capabilities and network characteristics.
+
+NOTE 1 – Network slices enable the creation of customized networks to provide flexible solutions for different market scenarios which have diverse requirements, with respect to functionalities, performance and resource allocation.
+
+NOTE 2 – A network slice may have the ability to expose its capabilities.
+
+NOTE 3 – The behaviour of a network slice is realized via network slice instance(s).
+
+**3.1.2 network slice instance** [b-ITU-T Y.3100]: An instance of network slice, which is created based on network slice blueprint.
+
+NOTE 1 – A network slice instance is composed of a set of managed run-time network functions, and physical/logical/virtual resources to run these network functions, forming a complete instantiated logical network to meet certain network characteristics required by the service instance(s).
+
+NOTE 2 – A network slice instance may also be shared across multiple service instances provided by the network operator. A network slice instance may be composed of none, one or more sub-network slice instances which may be shared with another network slice instance.
+
+**3.1.3 mobile network** [b-ITU-T Q.1762]: A network that provides wireless access to its services and supports mobility.
+
+**3.1.4 IMT-2020** [b-ITU-T Y.3100]: Systems, system components, and related technologies that provide far more enhanced capabilities than those described in [b-ITU-R M.1645].
+
+**3.1.5 network function** [b-ITU-T Y.3100]: In the context of IMT-2020, a processing function in a network.
+
+NOTE 1 – Network functions include but are not limited to network node functionalities, e.g., session management, mobility management and transport functions, whose functional behaviour and interfaces are defined.
+
+NOTE 2 – Network functions can be implemented on a dedicated hardware or as virtualized software functions.
+
+NOTE 3 – Network functions are not regarded as resources, but rather any network functions can be instantiated using the resources.
+
+**3.1.6 machine learning model** [ITU-T Y.3172]: Model created by applying machine learning techniques to data to learn from.
+
+NOTE 1 – A machine learning model is used to generate predictions (e.g., regression, classification, clustering) on new (untrained) data.
+
+NOTE 2 – A machine learning model may be encapsulated in a deployable fashion in the form of a software (e.g., virtual machine, container) or hardware component (e.g., IoT device).
+
+NOTE 3 – Machine learning techniques include learning algorithms (e.g., learning the function that maps input data attributes to output data).
+
+**3.1.7 service level agreement (SLA)** [b-ITU-T Y.3500]: Documented agreement between the service provider and customer that identifies services and service targets.
+
+NOTE 1 – A service level agreement can also be established between the service provider and a supplier, an internal group or a customer acting as a supplier.
+
+NOTE 2 – A service level agreement can be included in a contract or another type of documented agreement.
+
+## **3.2 Terms defined in this Recommendation**
+
+None.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|----------|-----------------------------------------------------------------------|
+| AI | Artificial Intelligence |
+| DDOS | Distributed Denial of Service |
+| FCAPS | Fault, Configuration, Accounting, Performance monitoring and Security |
+| IMT-2020 | International Mobile Telecommunication 2020 |
+| ML | Machine Learning |
+| M&O | Management and Orchestration |
+| NF | Network Function |
+| NSI | Network Slice Instance |
+| OAM | Operation, Administration and Maintenance |
+| QoE | Quality of Experience |
+| QoS | Quality of Service |
+| RCA | Root Cause Analysis |
+| SLA | Service Level Agreement |
+
+# **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance.
+
+# **6 Introduction of network slicing with AI-assisted analysis in IMT-2020 networks**
+
+## **6.1 Overview**
+
+The International Mobile Telecommunication 2020 (IMT-2020) network is expected to bring some new and enhanced capabilities. AI-assisted analysis in the IMT-2020 network will bring new opportunities to network operators, vendors and third parties.
+
+The IMT-2020 network introduces network slicing to provide customized and dedicated network services for vastly different industries running on shared physical infrastructure. It transforms traditional network services (e.g., the services over IMT-2000 networks) to IMT-2020 network services characterized with customization on functions, securities and resource isolation, and optimized topology to match with requirements of a particular service category or individual customers. Compared with traditional networking, network slicing based on network softwarization techniques [ITU-T Y.3150] provides flexibility, agility and diversity of network service offering to the IMT-2020 network; however, it causes complexity in network management and operation in exchange for its merits. From the viewpoint of operational costs, it is not so easy to increase human resource to deal with the problem. On the other hand, the assurance of network slice service level agreement (SLA) is a key role for service providers nowadays. The dynamicity of networking by network slicing have the risk of inducing unexpected network troubles because of its technical and service innovation aspects.
+
+Artificial intelligence (AI) including machine learning (ML) is a leading candidate to tackle these problems. To achieve optimized network management and operation for network slicing with the satisfied quality of experience (QoE) of network slice customers, the IMT-2020 network needs to introduce AI-assisted analysis, which has the capability of data analysis with intelligence to support automated and optimized network slicing.
+
+
+
+Figure 6-1: An overview of network slicing with AI-assisted analysis. The diagram shows a flow between three main components: AI-assisted analysis, Slice management and orchestration, and Slice customers. AI-assisted analysis (top) receives 'Network slice QoE information' from Slice customers (right) and sends 'Data analysis results' to Slice management and orchestration (bottom). Slice management and orchestration sends 'Network slice information' back to AI-assisted analysis. The network is divided into three parts: Access network (radio tower icon), Transport network (cloud icon), and Core network (switches icon). Slice customers are represented by server racks in a cloud. Reference: Y.3156(20)\_F6-1.
+
+**Figure 6-1 – An overview of network slicing with AI-assisted analysis**
+
+The overview of AI-assisted analysis for network slicing is shown in Figure 6-1, which includes: network slice customers as defined in clause 8.2 (e.g., telecom operators, service operators, and third parties), slice management and orchestration (M&O) in the IMT-2020 network as defined in [ITU-T Y.3111] and [ITU-T Y.3324], and AI-assisted analysis.
+
+The AI-assisted analysis acts as a medium for bridging the operator's network and the network slice customers. It collects network slice customer's QoE information and network slice information from the slice M&O as data sources, and gives analysis results by using intelligent algorithms.
+
+For example, for network slice resource optimization by using an intelligent algorithm, the AI-assisted analysis calculates a network resource allocation plan (e.g., targeted logical/physical resources, assigned bandwidth, and an execution schedule) that can match the customer's requirements. If the allocation plan is examined its feasibility and safeness, then the slice M&O triggers the dynamic adjustment of network resources.
+
+## 6.2 AI-assisted analysis for network slice lifecycle management
+
+The AI-assisted analysis supports the whole lifecycle management of each network slice instance (NSI). The network slice instance is a managed entity in an operator's network.
+
+NOTE – The lifecycle of the NSI is independent of the lifecycle of service instance(s). In particular, service instances are not necessarily active through the whole duration of the run-time phase of the supporting NSI.
+
+[ITU-T Y.3154] introduces the lifecycle management of the NSI as shown in Figure 6-2. The lifecycle management of the NSI conducts its two process phases: i) NSI preparation phase and ii) NSI runtime management phase.
+
+![Figure 6-2 – Lifecycle phases of an NSI [ITU-T Y.3154]. The diagram shows a flow from Preparation to Runtime management. Preparation includes Design and Resource arrangement. Runtime management includes Creation, Activation, In-NSI OAM, De-activation, and Termination.](cfef993dcc8fb513de79eb1f93cf26ae_img.jpg)
+
+```
+
+graph LR
+ subgraph Preparation
+ Design[Design]
+ Resource[Resource arrangement]
+ end
+ subgraph Runtime_management [Runtime management]
+ Creation[Creation] --> Activation[Activation]
+ Activation --> InNSIOAM[In-NSI OAM]
+ InNSIOAM --> Deactivation[De-activation]
+ Deactivation --> Termination[Termination]
+ end
+ Preparation --> Runtime_management
+
+```
+
+Y.3156(20)\_F6-2
+
+Figure 6-2 – Lifecycle phases of an NSI [ITU-T Y.3154]. The diagram shows a flow from Preparation to Runtime management. Preparation includes Design and Resource arrangement. Runtime management includes Creation, Activation, In-NSI OAM, De-activation, and Termination.
+
+**Figure 6-2 – Lifecycle phases of an NSI [ITU-T Y.3154]**
+
+Key phases and their procedures of network slicing that are expected to need AI-assisted analysis include, but are not limited to:
+
+- Network slice preparation phase: consists of network slice design including network slice template creation, and resource planning, pre-allocation and pre-provisioning;
+- NSI runtime management: consists of NSI creation, activation, inter/intra-NSI operation, administration and maintenance (OAM), de-activation, termination. Inter/Intra-NSI OAM includes fault, configuration, accounting, performance monitoring and security (FCAPS) functionalities for a single NSI and a coordination functionality between multiple NSIs.
+
+# 7 Requirements of AI-assisted analysis for network slicing in IMT-2020 networks
+
+The assurance of network slice SLA is a key role of a network slice service provider. To achieve the satisfied QoE of the network slice customers, AI-assisted analysis gives an effective way to support automated network slicing.
+
+An AI-assisted analysis functional entity may collect QoS/QoE related data from user equipment, access networks, transport networks, core networks, a network slice M&O etc. in order to analyze the performance of heterogeneous services together with network dynamics [ITU-T Y.3170].
+
+## 7.1 General requirements
+
+This clause introduces the general requirements of the AI-assisted analysis functional entity.
+
+[REQ G-1]: The AI-assisted analysis functional entity is required to support guaranteeing the SLA of network slice services for network slice customers including service providers and third parties.
+
+[REQ G-2]: The AI-assisted analysis functional entity is required to collect QoE information from network slice customers for supporting the lifecycle management of NSIs.
+
+[REQ G-3]: The AI-assisted analysis functional entity is required to interact with a slice M&O functional entity for supporting the lifecycle management of NSIs.
+
+[REQ G-4]: The AI-assisted analysis functional entity is recommended to have the capability of verifying whether impacts, which are caused according to analysis results, on network slice services fall within the tolerable range.
+
+[REQ G-5]: The AI-assisted analysis functional entity is recommended to support providing real-time differentiated quality of service (QoS) services for network slice customers.
+
+NOTE – Real-time differentiated QoS services are based on the AI-assisted analysis of the situation at service time and location, the characteristics of accessed business, customer communication rules including an access method, a network real-time load and other aspects, and form the best matching QoS control parameters. [ITU-T Y.3170] introduces relevant requirements on ML-based QoS assurance.
+
+## 7.2 Requirements for customer support
+
+Customer support with AI-assisted analysis for network slicing provides intelligent customer services to help network slice customers to select or arrange optimal customized network slice services.
+
+NOTE – [b-ITU-T Y.3103] describes a variety of business role models regarding network slice services.
+
+[REQ C-1]: The AI-assisted analysis functional entity for customer support is required to support optimal matching between network slice templates and the requirements of network slice customers.
+
+[REQ C-2]: The AI-assisted analysis functional entity for customer support is recommended to support providing network slice services with industry intelligent user association (i.e., the finding process on who has similar requirements).
+
+[REQ C-3]: The AI-assisted analysis functional entity for customer support is recommended to classify service scenarios to efficiently determine corresponding network slice design templates for providing personalized network slice services.
+
+[REQ C-4]: The AI-assisted analysis functional entity for customer support is required to support intelligent customer services using a self-service portal, which provides consultation, self-customization including the arrangement of a network slice template and other service support.
+
+## **7.3 Requirements for network slice preparation**
+
+Network slice preparation with AI-assisted analysis is a set of processes before network slice creation. For example, network slice instance templates for resource allocation can be revised by AI-assisted analysis.
+
+[REQ P-1]: The AI-assisted analysis functional entity for network slice preparation is required to support designing network slices based on network slice customers' intentions.
+
+[REQ P-2]: The AI-assisted analysis functional entity is recommended to have the capability to interpret customer requirements and change them into detailed specifications of an NSI.
+
+[REQ P-3]: The AI-assisted analysis functional entity for network slice preparation is required to support automated pre-configuration of a network slice instance [ITU-T Y.3153].
+
+[REQ P-4]: The AI-assisted analysis functional entity for network slice preparation is required to support resource allocation based on an operator's deployment policy to meet SLA requirements.
+
+[REQ P-5]: The AI-assisted analysis functional entity for network slice preparation is required to support the preparation processes of multiple NSIs with optimal shared resources if resource sharing is possible.
+
+[REQ P-6]: The AI-assisted analysis functional entity for network slice preparation is required to support the examination of feasibility for providing a new network slice instance.
+
+## **7.4 Requirements for automation of runtime management**
+
+Network slice life cycle management with AI-assisted analysis covers run-time processes: creation, activation, inter/intra-slice OAM, de-activation and termination to realize an optimized network slice.
+
+[REQ R-1]: The AI-assisted analysis functional entity for runtime management is recommended to have the capability to take into account the change of operational policies.
+
+NOTE 1 – The IMT-2020 network may change a network policy adapted to a network slice depending on network situations (e.g., a network uses a pre-set general policy in case of normal situation, and the network replaces with an optional policy in case of network failures).
+
+[REQ R-2]: The AI-assisted analysis functional entity for runtime management is required to support automated processes to create, activate, inter/intra slice OAM, deactivate and terminate a network slice.
+
+[REQ R-3]: The AI-assisted analysis functional entity for runtime management is recommended to support an operator to create and update the policy of network slice automation.
+
+[REQ R-4]: The AI-assisted analysis functional entity for runtime management is required to support automated healing for a network slice instance.
+
+[REQ R-5]: The AI-assisted analysis functional entity for runtime management is required to support automated optimization including automated scaling within and between NSIs.
+
+NOTE 2 – The NSIs can be modified automatically to avoid degradation of services in case of network function overload, dynamic topology change, etc.
+
+## **7.5 Requirements for inter/intra-slice OAM**
+
+Inter/Intra-slice OAM with AI-assisted analysis provides fault location detection capability and supports automated optimization and healing actions for a network slice.
+
+[REQ O-1]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to have the capability of monitoring and analysing the status of the target NSIs, including the status of network functions and services.
+
+NOTE – Examples of parameters of the NSIs to be monitored are throughput, latency, the number of connections, etc. Based on monitored and analysed results, a slice M&O functional entity may automatically re-configure some slice-specific parameters for the NSIs to improve the performance of services provided via the NSIs.
+
+[REQ O-2]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to have the capability of gathering automated process results.
+
+[REQ O-3]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to support resolving the conflicts of automated optimization actions for a network slice instance [ITU-T Y.3153].
+
+[REQ O-4]: The AI-assisted analysis functional entity for inter/intra-slice OAM is recommended to support preventing the conflicts of automated optimization actions for a network slice instance [ITU-T Y.3153].
+
+[REQ O-5]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to provide traffic prediction and the results of corresponding resources requirements analysis to support proactively triggering the scale up/down of NSIs to adapt a tidal effect.
+
+[REQ O-6]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to support the efficient utilization of common virtual resources for multiple NSIs when it is possible to coordinate requirements between NSIs.
+
+[REQ O-7]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to have the capability of performing data mining of historical alarms (e.g., to build a diagnostic rule base and to find out the root cause of the alarms of NSIs).
+
+[REQ O-8]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to have the capability of predicting abnormal status and to support performing prevention actions.
+
+[REQ O-9]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to support the automatic selection of optimal recovery actions when it detects faults.
+
+[REQ O-10]: The AI-assisted analysis functional entity for inter/intra-slice OAM is recommended to support the constant improvement of automated workflows of the network slice M&O.
+
+[REQ O-11]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to have the capability of achieving QoS detection and prediction based on massive data collection, modelling and analysis.
+
+[REQ O-12]: The AI-assisted analysis functional entity for inter/intra-slice OAM is required to support QoS relevant warning.
+
+[REQ O-13]: The AI-assisted analysis functional entity for inter/intra-slice OAM is recommended to support giving notification and/or advice (e.g., early termination of business, change of business operations) to operators in advance of taking operation and maintenance actions when a serious situation change occurs including failures are detected.
+
+# 8 High-level framework of AI-assisted analysis for network slicing
+
+## 8.1 Functional description of AI-assisted analysis
+
+An AI-assisted analysis functional entity is responsible to give data analysis results used for the optimization of network slice operation with AI technologies including machine learning (ML) [ITU-T Y.3172].
+
+The AI-assisted analysis includes three processes: data collection, model training and analysis with AI/ML models.
+
+
+
+```
+graph LR; subgraph AI_assisted_analysis [AI-assisted analysis]; Data_collection[Data collection]; Model_training[Model training]; Analysis[Analysis with AI/ML model]; end; QoE_info[QoE information] --> Data_collection; Network_slice_info[Network slice information] --> Data_collection; Data_collection --> Model_training; Data_collection --> Analysis; Model_training --> Analysis; Analysis --> Analysis_result[Analysis result];
+```
+
+The diagram illustrates the key processes of AI-assisted analysis. It shows a central box labeled "AI-assisted analysis" containing three main components: "Data collection", "Model training", and "Analysis with AI/ML model". "Data collection" receives two inputs from the left: "QoE information" and "Network slice information". It then feeds into both "Model training" and "Analysis with AI/ML model". "Model training" also feeds into "Analysis with AI/ML model". Finally, "Analysis with AI/ML model" produces an "Analysis result" on the right. The diagram is labeled Y.3156(20)\_F8-1.
+
+Flowchart of AI-assisted analysis processes
+
+**Figure 8-1 – Key processes of AI-assisted analysis**
+
+The AI-assisted analysis functional entity uses the following two types of data:
+
+- a) Network slice QoE information: collected from network slice customers including third parties who consume network slice services. This information, which may include network slice QoE requirements, can be composed of:
+ - i) Network coverage area;
+ - ii) Number of subscribers;
+ - iii) Customer satisfaction.
+- b) Network slice information: collected via network slice management and orchestration (M&O), which can manage different network domains. This information includes:
+ - i) Network function (NF) performance measurement data;
+ - ii) Fault supervision data;
+ - iii) Network QoS data.
+ - iv) Resource usage data (e.g., the usage rate of allocated resources for a specific NSI).
+
+Model training, which includes ML model training, with advanced AI/ML algorithms elaborates specific models for network slicing.
+
+Trained models may include a traffic prediction model, a faulty root cause analysis (RCA) model, a QoE evaluation model, etc. The traffic prediction model provides a useful traffic prediction based on the analysis of historical and real-time traffic data of network slice instances. The faulty RCA model is to identify a root failure and derivative failures by reasoning with correlation rules. The QoE evaluation model maps QoE information perceived by network slice customers with QoS information provided by network slice M&O.
+
+NOTE – In order to obtain optimal user service experience, it is necessary to measure service experience of individual users by taking corresponding network attributes with proper weights into account (e.g., upload/download capacity, jitter, maximum latency, network availability and the other parameters dedicated to specific service requirements.)
+
+Based on techniques on big data analysis and AI-assisted feature mining, the AI-assisted analysis functional entity gives the data analysis results, it includes, but not limited to what are listed in Table 8-1.
+
+**Table 8-1 – Examples of input and output of AI-assisted analysis**
+
+| Analysis task | Input data | Output results | Description |
+|-----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Template design | – Service requirements (e.g., service types (URLLC, eMBB, MMTC, V2X), QoE requirements) – Resource usage data – Configuration parameters – Basic slice templates | Customized slice template including reasonable sub network slice templates for access, transport and core networks, and resource planning | Perform the mapping of QoE requirements and slice template parameters. Applicable AI techniques for this task are deep learning and supervised learning. |
+| Traffic prediction | Past and present traffic data | Traffic at the next moment | Predict the trend of load. Applicable AI techniques is deep learning such as sequence prediction algorithm. |
+| Resources optimization on re-allocation | – Resource usage of NSIs – Attributes of NSI – The number of end-users | Slice resource scheduling scheme | Optimize resources within and between NSI(s). Applicable AI techniques for this task are the combination of mathematical programming and reinforcement learning. |
+| Alarm root cause analysis | – Alarm data – Resource usage data – Topology data | Identified root cause including its physical/logical location | Automated RCA and diagnosis. Applicable AI techniques for this task is using the combination of supervised learning and an RCA model such as Bayesian network. |
+
+## 8.2 Relations with automated slice M&O
+
+[ITU-T Y.3324] introduces high-level autonomic management and control architecture for IMT-2020 network slice life cycle management. Figure 8-2 illustrates possible connections between an autonomic network slice M&O defined in [ITU-T Y.3324] and an AI-assisted analysis functional entity.
+
+
+
+The diagram illustrates the functional architecture of IMT-2020 slice life-cycle management and orchestration. It is organized into several layers and components:
+
+- External Entities (Left):**
+ - Network slice customer:** Interacts with the top layer of the orchestration block.
+ - Intra-network slice management:** Interacts with the bottom layer of the orchestration block.
+- IMT-2020 slice life-cycle management and orchestration (Central Block):**
+ - Top Layer:** Slice life-cycle management customer care support.
+ - Middle Layers:**
+ - Left column: Slice capacity planning and optimization, Inter-slice orchestration, Slice security management, Slice resource monitoring and analytics, Autonomic slice life-cycle management decision (grey box).
+ - Right column: Slice provisioning, Slice fault management, Slice charging management, Slice resource repository, Knowledge information exchange repository (grey box).
+ - Bottom Layer:** External management entity support.
+- AI-assisted analysis (Right):** A grey box that receives input from the Network slice customer, Intra-network slice management, and the central orchestration block. It has bidirectional connections with the Autonomic slice life-cycle management decision and Knowledge information exchange repository.
+
+Reference: Y.3156(20)\_F8-2
+
+Figure 8-2: Relations between and AI-assisted analysis and autonomic slice management and orchestration. The diagram shows a central 'IMT-2020 slice life-cycle management and orchestration' block containing various functional entities. It interacts with 'Network slice customer' and 'Intra-network slice management' on the left, and 'AI-assisted analysis' on the right. Grey boxes highlight 'Autonomic slice life-cycle management decision' and 'Knowledge information exchange repository'.
+
+**Figure 8-2 – Relations between and AI-assisted analysis and autonomic slice management and orchestration**
+
+In Figure 8-2, grey boxes "autonomic slice lifecycle management decision" and "knowledge information exchange repository", are main autonomic functional entities in the network slice M&O. These two entities interact with an AI-assisted analysis functional entity.
+
+- Autonomic slice life-cycle management decision functional entity: provides autonomic capabilities for an overall network slice life-cycle management perspective, which is highest-level automaticity effecting on network-wide self-management policy decisions, a single NSI self-management and control actions.
+- Knowledge information exchange repository functional entity: provides capabilities to store the network slice life-cycle management-wide self-management policy information.
+
+A network slice customer and an intra-network slice management are data origins for AI-assisted analysis:
+
+- Network slice customer: requests network services by using network slicing and provides QoE information;
+- Intra-network slice management: is a management support functional entity provided for each NSI and provides NSI information.
+
+The AI-assisted analysis functional entity is assumed to collect the data indirectly via the following customer care support and external management entity support defined in [ITU-T Y.3111]:
+
+- Slice lifecycle management customer care support: provides a standard interface to the slice lifecycle M&O to interact with network slice customers and applications. It supports requesting and receiving management operations and associated information in the slice M&O;
+- External management entity support: provides an interface to external management systems including network slice management.
+
+NOTE – Details of the other functional entities in Figure 8-2 are introduced in [ITU-T Y.3111].
+
+# **9 Security consideration**
+
+The IMT-2020 network is subject to security and privacy measures. Sensitive information should be protected as a high priority in order to avoid leaking and unauthorized access. The security requirements are based on [ITU T Y.3111], [b-ITU-T Y.2701]. The types of generic threat to IMT-2020 network slicing with AI-assisted analysis are as follows:
+
+- Information destruction;
+- Information corruption or modification;
+- Information theft, removal or loss;
+- Information disclosure;
+- Service interruption.
+
+The major security requirements for IMT-2020 network slicing with AI-assisted analysis are listed in the following:
+
+[REQ S-1]: The AI-assisted analysis functional entity is required to ensure that corresponding measures are taken to deal with relevant attacks when the above-mentioned security threats occur.
+
+NOTE – For example, the AI-assisted analysis functional entity will determine whether network traffic belongs to a malicious distributed denial of service (DDoS) attack based on a deep learning algorithm, so as to quickly decide to deploy appropriate countermeasures.
+
+[REQ S-2]: The AI-assisted analysis functionality is required to prevent unauthorized access and data leakage, no matter whether they are malicious or not, by implementing mechanisms related to authentication and authorization, external attack protection, etc. [ITU T Y.3172].
+
+[REQ S-3]: The AI-assisted analysis functionality is recommended to analyse the traffic, log and other information to separate and identify the abnormal traffic and user behaviour in the network, and on this basis, design the flow and behaviour pattern recognition model, so as to identify potential risks (such as unknown malicious code / file, phishing, hidden Trojan horse, abnormal operation behaviour, etc.) and increase network security.
+
+[REQ S-4]: The AI-assisted analysis functionality is recommended to evaluate the security levels of an automatically generated NSI to determine if it can provide customized security services (such as integrity protection, confidentiality protection, hardware isolation, software isolation, anti DDoS attack, anti-virus and anti-malware).
+
+## Bibliography
+
+- [b-ITU-R M.1645] Recommendation ITU-R M.1645 (2003), *Framework and overall objectives of the future development of IMT-2000 and systems beyond IMT-2000*.
+- [b-ITU-T Q.1762] Recommendation ITU-T Q.1762/Y.2802 (2007), *Fixed-mobile convergence general requirements*.
+- [b-ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1*.
+- [b-ITU-T Y.3100] Recommendation ITU-T Y.3100 Corrigendum 1 (2018), *Terms and definitions for IMT-2020 network*.
+- [b-ITU-T Y.3103] Recommendation ITU-T Y.3103 (2018), *Business role-based models in IMT-2020*.
+- [b-ITU-T Y.3151] Recommendation ITU-T Y.3151 (2019), High level technical characteristics of network slice support for IMT-2020 – part: SDN.
+- [b-ITU-T Y.3500] Recommendation ITU-T Y.3500 (2014) | ISO/IEC 17788:2014, *Information technology – Cloud computing – Overview and vocabulary*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3157-202102-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94d45ee0d7450a0c276bffad33306ce1ec96de62
--- /dev/null
+++ b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c981deef08fa0ff69264e0a06c61f5dd291a362fb37303b3216e33a0ba5040e9
+size 5841
diff --git a/marked/Y/T-REC-Y.3157-202102-I_PDF-E/5a95b187de0044da69b7322e04761b86_img.jpg b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/5a95b187de0044da69b7322e04761b86_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3a48528eab701a9682655c47ac85c0683f867825
--- /dev/null
+++ b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/5a95b187de0044da69b7322e04761b86_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:279f6fac642f5bf6d3b42d2d7128f0f8ef48d4fdcf56dfb14bc33babcbc769d9
+size 59293
diff --git a/marked/Y/T-REC-Y.3157-202102-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b59fefa3075aac5e51a08946e19ccdf47e5e28d8
--- /dev/null
+++ b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7f19fd4f8b781706fcd2c89b37d88fb01c5370ea1aa552fc20a76321fe1d896f
+size 32819
diff --git a/marked/Y/T-REC-Y.3157-202102-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a80bb05e20b39ae300c1354f9aeaaec5589b31ac
--- /dev/null
+++ b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3f3efcb68cae3399026701fe14c018927d35bb273b77808a9f3195d461d47efa
+size 56301
diff --git a/marked/Y/T-REC-Y.3157-202102-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..874a67f478f06bac95f6e05361b4fd3a5ec79640
--- /dev/null
+++ b/marked/Y/T-REC-Y.3157-202102-I_PDF-E/raw.md
@@ -0,0 +1,458 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.3157
+
+(02/2021)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Future networks
+
+# --- **IMT-2020 network slice configuration**
+
+Recommendation ITU-T Y.3157
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3599 |
+| BIG DATA | Y.3600–Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800–Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | |
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.3157
+
+## IMT-2020 network slice configuration
+
+## Summary
+
+Recommendation ITU-T Y.3157 specifies a network slice configuration in order to dynamically create and manage network slice instances (NSIs) in the International Mobile Telecommunications-2020 (IMT-2020) network. Detailed topics are methods for: creation of an NSI; provision of quality of service (QoS) to the network slice; and association of user equipment (UE) application services with the NSI.
+
+Network slicing is regarded as a key technology in the successful deployment of the IMT-2020 network. The concept of network slicing and use cases in the IMT-2020 network are introduced in Recommendation ITU-T Y.3112.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3157 | 2021-02-13 | 13 | 11.1002/1000/14597 |
+
+## Keywords
+
+Network slice, network slice instance, network slice template, network slice type indicator.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2021
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|--------------------------------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Introduction ..... | 3 |
+| 7 Network slice template ..... | 4 |
+| 7.1 Network slice type indicator..... | 4 |
+| 7.2 Network slice key performance indicator on protocol data unit session..... | 5 |
+| 7.3 Other key performance indicators ..... | 5 |
+| 8 Network slice configuration ..... | 5 |
+| 9 Procedures of network slice update ..... | 6 |
+| 10 Security considerations..... | 8 |
+| Bibliography..... | 9 |
+
+
+
+## Recommendation ITU-T Y.3157
+
+## IMT-2020 network slice configuration
+
+# 1 Scope
+
+This Recommendation specifies a dynamic network slice configuration in order to dynamically create and manage network slice instances (NSIs) in the International Mobile Telecommunications-2020 (IMT-2020) network. The network slice configuration changes information about functional constituents (e.g., capacity of virtual network function (NF), capacity of virtual link and topology) in a dedicated NSI. The network slice configuration is updated when the network slice is modified according to the instructions of NSI life cycle management.
+
+This Recommendation covers the following aspects:
+
+- an overview of a network slice template, including its attributes and network slice key performance indicators (KPIs);
+- relations between NSI modification and the configuration file;
+- update procedures for dynamic network slices.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.1541] | Recommendation ITU-T Y.1541 (2011), Network performance objectives for IP-based services . |
+| [ITU-T Y.3111] | Recommendation ITU-T Y.3111 (2017), IMT-2020 network management and orchestration framework . |
+| [ITU-T Y.3112] | Recommendation ITU-T Y.3112 (2018), Framework for the support of network slicing in the IMT-2020 network . |
+| [ITU-T Y.3153] | Recommendation ITU-T Y.3153 (2019), Network slice orchestration and management for providing network services to 3rd party in the IMT-2020 network . |
+| [ITU-T Y.3156] | Recommendation ITU-T Y.3156 (2020), Framework of network slicing with AI-assisted analysis in IMT-2020 networks . |
+| [ITU-R M.2083] | Recommendation ITU-R M.2083 (2015), IMT vision – Framework and overall objectives of the future development of IMT for 2020 and beyond . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 network slice** [b-ITU-T Y.3100]: A logical network that provides specific network capabilities and network characteristics.
+
+NOTE 1 – Network slices enable the creation of customized networks to provide flexible solutions for different market scenarios which have diverse requirements, with respect to functionalities, performance and resource allocation.
+
+NOTE 2 – A network slice may have the ability to expose its capabilities.
+
+**3.1.2 network slice blueprint** [b-ITU-T Y.3100]: A complete description of the structure, configuration and workflows on how to create and control a network slice instance during its life cycle.
+
+NOTE – A network slice template can be used synonymously with a network slice blueprint.
+
+**3.1.3 network slice instance** [b-ITU-T Y.3100]: An instance of network slice, which is created based on a network slice blueprint.
+
+NOTE 1 – A network slice instance is composed of a set of managed run-time network functions, and physical/logical/virtual resources to run these network functions, forming a complete instantiated logical network to meet certain network characteristics required by the service instance(s).
+
+NOTE 2 – A network slice instance may also be shared across multiple service instances provided by the network operator. A network slice instance may be composed of none, one or more sub-network slice instances which may be shared with another network slice instance.
+
+NOTE 3 – The behaviour of a network slice is realized via network slice instance(s).
+
+## **3.2 Terms defined in this Recommendation**
+
+None.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|-----------------------------------------|
+| 5G | fifth Generation |
+| 5QI | 5G QoS Identifier |
+| AMF | Access Mobility Function |
+| CN | Core Network |
+| CUG | Closed User Group |
+| DL/UL | Down Link/Up Link |
+| eMBB | enhanced Mobile Broadband |
+| GRPS | General Packet Radio Service |
+| GTP | GRPS Tunnelling Protocol |
+| IMT | International Mobile Telecommunications |
+| IP | Internet Protocol |
+| KPI | Key Performance Indicator |
+| mMTC | massive Machine Type Communication |
+| NACF | Network Attachment Control Function |
+| NF | Network Function |
+| NFI | Network Function Instance |
+| NSI | Network Slice Instance |
+| NST | Network Slice Template |
+| NSTI | Network Slice Type Indicator |
+
+| | |
+|-------|-------------------------------------------|
+| OAM | Operation, Administration and Maintenance |
+| PCF | Packet Control Function |
+| PDU | Protocol Data Unit |
+| QFI | QoS Flow Identifier |
+| QoS | Quality of Service |
+| RAN | Radio Access Network |
+| SMF | Session Management Function |
+| SST | Slice Service Type |
+| TN | Transport Network |
+| UE | User Equipment |
+| UPF | User Plane Function |
+| URLLC | Ultra-Reliable Low-Latency Communication |
+| V2X | Vehicle to everything |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The phrase "is required to" indicates a requirement that must be strictly followed and from which no deviation is permitted, if conformity to this Recommendation is to be claimed.
+
+The phrase "is recommended to" indicates a requirement that is recommended, but which is not absolutely required. Thus, this requirement need not be present to claim conformity.
+
+# 6 Introduction
+
+Network slicing is regarded as a key technology in the deployment of the IMT-2020 network. In this regard, relevant Recommendations relating to the network slicing framework and management are [ITU-T Y.3111], [ITU-T Y.3112] and [ITU-T Y.3153]. [ITU-T Y.3111] provides an overview of IMT-2020 network management and orchestration. [ITU-T Y.3112] describes the concept of network slicing and use cases when a single piece of user equipment (UE) simultaneously attaches to multiple network slices in the IMT-2020 network. [ITU-T Y.3153] further describes network slice orchestration and management for the provision of network services to a third party in the IMT-2020 network. They briefly introduce the network slice template and the related attributes. This Recommendation further describes the network slice template and the network slice configuration.
+
+The architecture of network slice management and orchestration is depicted schematically in Figure 6-1, which is based on Figure 1 of [ITU-T Y.3153]. Network slicing management and orchestration architecture basically consists of three functional entities: the network slice customer; slice management and orchestration; and resource management. The network slice customer is an end-user or a group of end users (e.g., tenant, vertical industry and third party). A network slice template represents the characteristics of a network slice that is managed by slice management and orchestration. The network slice template can be generated by slice management and orchestration by designing NFs and their topology in a specific network slice based on different scenarios and requirements. As shown in Figure 6-1, the network slice template consists of sub network slice templates relevant to a specific network domain, such as a radio access network (RAN), a core network (CN) and a transport network (TN) in the IMT-2020 network. The sub network slice templates are filled with information on each domain. According to the sub network slice templates, resource management conducts the life cycle of the NFs required and the resources they need.
+
+
+
+```
+
+graph TD
+ A[Network slice customer] --- B[Slice management and orchestration]
+ B --- C[Resource management]
+ B --- D[Network slice template]
+ B --- E["Sub-network slice template
+(RAN, CN, TN)"]
+ C --- F[Configuration file]
+
+```
+
+The diagram illustrates the abstracted architecture of network slice management and orchestration. It consists of three main hierarchical levels connected by vertical lines. The top level is a box labeled "Network slice customer". This connects to a middle box labeled "Slice management and orchestration". Inside this middle box are two sub-boxes: "Network slice template" and "Sub-network slice template (RAN, CN, TN)". The middle box connects to a bottom box labeled "Resource management", which contains a sub-box labeled "Configuration file".
+
+Y.3157(21)\_F6-1
+
+Abstracted architecture of network slice management and orchestration diagram
+
+**Figure 6-1 – Abstracted architecture of network slice management and orchestration**
+
+# 7 Network slice template
+
+This clause mainly focuses on key attributes of a network slice template, particularly in terms of the type and KPIs of a network slice.
+
+A network slice template is generated and managed by slice management and orchestration according to service requirements from a network slice customer. The service requirements are translated into the network slice template. The network slice customers are operators, third parties or may be an individual user or a group of users.
+
+The network slice template moreover includes detailed characteristics of the network slice to reflect customer service requirements. The network slice identifier is used to distinguish a specific template when multiple network slice templates exist. Furthermore, additional information related to network slice capacity of are described hereafter.
+
+NOTE – The generic network slice template (GST) [b-GSMA NG.116] and the service profile [b-ETSI TS 128 530] are specified by GSMA and 3GPP SA5, respectively.
+
+## 7.1 Network slice type indicator
+
+In the IMT-2020 network, network slices can be explicitly linked to all kinds of services and user groups.
+
+The network slice type indicator (NSTI) is key information for the identification of a network slice and is associated with an application service of a piece of UE with the network slice [ITU-T Y.3112]. One key attribute of an NSTI is a slice service type (SST). Examples of SSTs are ebb, ultra-reliable low-latency communication (URLLC), massive machine type communication (mMTC), and vehicle to everything (V2X). They represent categorizations of eight parameters, which are key capabilities of the IMT-2020 and also called KPIs. The eight KPIs are: peak data rate; user experienced data rate; latency; mobility; connection density; energy efficiency; spectrum efficiency; and area traffic capacity [ITU-R M.2083]. The SSTs indicate a broad range of values with respect to the eight KPIs. To uniquely indicate the values, the attributes of the network slice template include the KPIs, e.g., up-link throughput and latency, down-link throughput and latency, mobility and connection density [ITU-T Y.3112].
+
+However, the usage of SSTs is limited to at most four (i.e., enhanced mobile broadband (eMBB), URLLCs, mMTCs and V2X) as standard values.
+
+When an NSTI is further extended to include additional SSTs such as eMBB + URLLC, additional service requirements may be optional (e.g., throughput or latency). If a closed user group (CUG) of
+
+an NSTI is used to indicate a specific KPI, the CUG may represent additional performance requirements.
+
+[REQ-1] The IMT-2020 network is recommended to cover a wide variety of SST values to support diverse service requirements (e.g., expansion of SST values, usage of a mixture of SST values).
+
+## **7.2 Network slice key performance indicator on protocol data unit session**
+
+The network slice template includes KPIs as well as an NSTI. The network slice accommodates protocol data unit (PDU) sessions and packet flows to network slice customers. Therefore, the KPI of the network slice is assigned to guarantee the quality of service (QoS) of PDU sessions and packet flows.
+
+NOTE 1 – In [b-ITU-T Y.3106], the peak data rate of IMT-2020 for eMBB is expected to support up to 20 Gbit/s. For wide-area coverage cases, a user-experienced data rate of 100 Mbit/s is expected to be enabled. IMT-2020 is expected to support a connection density of up to $10^6/\text{km}^2$ , e.g., in mMTC scenarios. IMT-2020 would be able to provide 1 ms over-the-air latency for URLLCs.
+
+Network QoS classes and a packet flow are described in [ITU-T Y.1541]. A packet flow can be more specifically described as traffic associated with a given connection or connectionless stream having the same source host address, destination host address, protocol and port number. A single network QoS class will be allocated to the packet flow.
+
+NOTE 2 – The network QoS classes are specified in both Tables 1 and 3 of [ITU-T Y.1541] presenting bounds on network performance between user network interfaces. Different packet flows can have the same network QoS class if their QoS requirements are within a certain pre-configured level.
+
+NOTE 3 – Each network QoS class creates a specific combination of bounds on Internet protocol (IP) packet performance values indicating transfer delay, delay variation, loss ratio and error ratio.
+
+NOTE 4 – The network QoS classes of 3GPP differs from those of ITU-T. In [b-3GPP TS 23.501], a QoS flow identifier (QFI) is used to identify a QoS flow having QoS differentiation. A fifth generation (5G) QoS identifier (5QI) may be used for a QFI as a default. The 5QIs include various QoS classes including packet loss rate, packet delay budget and maximum data burst volume.
+
+The packet flow is generated at the request of network slice customers, and a session management function (SMF) in the IMT-2020 network initiates a PDU session based on pre-defined QoS profiles.
+
+When the SMF modifies the session, it can update QoS profiles simultaneously. The QoS class of packet flow should be set within the range of the KPI that the network slice is supposed to support.
+
+[REQ-2] The IMT-2020 network is required to allocate a QoS class of a packet flow within the range of the KPI that the network slice supports.
+
+## **7.3 Other key performance indicators**
+
+Additional KPI information related to the capacity of a network slice are considered in this clause.
+
+The maximum number of pieces of UE quantifies the maximum number that can access the network slice simultaneously. This information may be associated with the performance of the network attachment control function (NACF), which handles a registration request message to a network slice. The maximum number of PDU sessions describes the maximum number of concurrent sessions supported by the network slice. This information may be associated with the performance of the SMF, which handles a PDU session establishment message to the network slice. Other KPI information may be added to the network slice template.
+
+# **8 Network slice configuration**
+
+Slice management and orchestration generates a configuration file that is used to configure sub network slices and transfers it to resource management before or during network slice initialization. An NSI is instantiated by resource management according to the network slice template generated by
+
+slice management and orchestration. Resource management assigns the necessary resources to the NSI. The configuration file includes provisioning information to instantiate the NSI. For example, network resource information may be a part of the configuration file. The network resource information includes all resources assigned to the NSI.
+
+NSI modification in the run-time phase could map to several workflows, e.g., changes in NSI capacity, changes in NSI topology and NSI reconfiguration.
+
+NSI modification can be triggered by receiving new network slice-related requirements from network slice customers or as the result of NSI supervision. The former case is mentioned in [ITU-T Y.3153] from the third part aspect. The latter case is described in clause 9 from the network slice monitoring aspect.
+
+NSI modification may change the capacity or topology of the NSI.
+
+NSI termination may terminate the constituents of an NSI that is not used by other NSI(s). After the termination phase, that NSI no longer exists.
+
+# 9 Procedures of network slice update
+
+High-level configuration processes of an NSI are illustrated in Figure 9-1. The preparation of a network slice template is the first phase before instantiating a new NSI; subsequently, the NSI is created, configured and activated accordingly as described in [ITU-T Y.3156].
+
+The network slice template is filled with the allocated values of the resource, if the NSI is successfully created. During the run-time phase, the NSI is monitored and controlled to meet QoS and performance requirements until the end of the life cycle of the NSI.
+
+Performance measurement may be made in the NF of each NSI or by operation, administration and maintenance (OAM) functions to monitor the KPI.
+
+During the run-time phase, the configuration of the NSI is modified if an NSI KPI is not able to support pre-defined service requirements, as shown in Figure 9-1.
+
+Network function instances (NFIs) (e.g., NACF, SMF or user plane function (UPF)) may measure and collect the relevant performance values (e.g., the number of pieces of UE in the NACF). If the measured values reach a certain limit, an appropriate NF may directly request an update of the NSI configuration to slice management and orchestration or via OAM.
+
+Slice management and orchestration can scale in additional NFs to the NSI, and the capacity of the NSI can be updated. The topology of the NSI can be modified for load balancing among the NFs by adding extra ones to the existing topology.
+
+
+
+Figure 9-1: High-level configuration processes of a network slice instance. The diagram shows a 'Network slice template' box on the left. Two blue arrows labeled 'Create' point from this template to two separate boxes representing 'NSI#1' and 'NSI#2'. Each NSI box contains a sequence of three components: NACF#1, SMF#1, and UPF#1 for NSI#1; and NACF#2, SMF#2, and UPF#2 for NSI#2. A blue arrow labeled 'Modify' points from each NSI box to a modified version of the same NSI. In the modified NSI#1, a line connects NACF#1 to a second SMF#1, which then connects to UPF#1. In the modified NSI#2, a line connects NACF#2 to a second SMF#2, which then connects to UPF#2. The diagram is labeled Y.3157(21)\_F9-1 in the bottom right corner.
+
+**Figure 9-1 – High-level configuration processes of a network slice instance**
+
+The general procedures of network slice configuration are shown in Figure 9-2.
+
+NOTE 1 – The NF belonging to a certain NSI can monitor and collect the relevant performance measurements as specified in [b-3GPP TS 28.552].
+
+For example, the NACF (also known as the access mobility function (AMF)) may perform the performance measurement in terms of the number of registered subscribers. The performance measurement for the number of PDU sessions and the number of general packet radio service (GRPS) tunnelling protocol (GTP) data packets are monitored by the SMF and UPF, respectively.
+
+
+
+```
+sequenceDiagram
+ participant NF
+ participant Resource management
+ participant KPI measurement NF/OAM
+ participant Slice management and orchestration
+
+ Note over NF, Resource management: 0) NSI creation
+ Note over NF: 1) Performance measurement
+ NF->>KPI measurement NF/OAM: 2) Measurement report
+ Note over KPI measurement NF/OAM: 3) Measurement data collection
+ KPI measurement NF/OAM->>Slice management and orchestration: 4) Measurement report
+ Note over Slice management and orchestration: 5) NSI performance verification
+ Slice management and orchestration->>Resource management: 6) NSI configuration update
+ Note over Resource management, NF: 7) NSI modification
+```
+
+Sequence diagram illustrating the Procedure of network slice configuration. The diagram shows four lifelines: NF, Resource management, KPI measurement NF/OAM, and Slice management and orchestration. The steps are: 0) NSI creation (NF to Resource management), 1) Performance measurement (NF), 2) Measurement report (NF to KPI measurement NF/OAM), 3) Measurement data collection (KPI measurement NF/OAM), 4) Measurement report (KPI measurement NF/OAM to Slice management and orchestration), 5) NSI performance verification (Slice management and orchestration), 6) NSI configuration update (Slice management and orchestration to Resource management), and 7) NSI modification (Resource management to NF).
+
+**Figure 9-2 – Procedure of network slice configuration**
+
+Step 0: Slice management and orchestration create an NSI based on a network slice template (NST). The NSI consists of several NFIs such as NACF, SMF, UPF and packet control function (PCF). NSI capacity depends on NFI capacity. The NSI capacity can be changed by scaling NFIs in or out.
+
+Step 1: The NFIs within the NSI start performance measurement when the NSI is activated to monitor and ensure NSI performance. The measurement result is delivered periodically or when a pre-defined threshold is reached.
+
+NOTE 2 – The NACF instance measures the number of terminals connecting to the NSI. The SMF instance measures the number of sessions connecting to the NSI. The UPF instance measures the down link/up link (DL/UL) packet volume through the NSI. The UPF instance measures the DL/UL packet delay through the NSI.
+
+Step 2: Each NF delivers its own measurement data to a KPI measurement NF. The NF can deliver the measurement data directly to slice management and orchestration if the KPI measurement NF cannot support the measurement report.
+
+Step 3: The KPI measurement NF or OAM collects the measurement data.
+
+Step 4: The KPI measurement NF delivers the measurement report for slice management and orchestration to initiate an NSI configuration update if needed.
+
+Step 5: Slice management and orchestration verifies the requested performance level of the NSI. If the requested performance level is higher than pre-defined thresholds, the NSI configuration is updated to increase the NSI capacity by scaling in relevant NFIs. If the requested performance level is lower than the thresholds, the NSI configuration is updated to decrease NSI capacity by scaling out the relevant NFIs.
+
+Step 6: Slice management and orchestration instructs the scaling in or out of NFs to increase or decrease the number of NFs.
+
+Step 7: NSI capacity is appropriately modified to ensure NSI performance. The NFIs activate and continue relevant performance measurement.
+
+# **10 Security considerations**
+
+This Recommendation specifies a network slice template and procedures of network slice configuration. The descriptions of network slices are related to network management and orchestration. Therefore, security considerations concerning IMT 2020 network management and orchestration [ITU-T Y.3111] can be applied.
+
+## Bibliography
+
+- [b-ITU-T Y.3100] Recommendation ITU-T Y.3100 (2018), *Terms and definitions for IMT-2020 network*.
+- [b-ITU-T Y.3106] Recommendation ITU-T Y.3106 (2019), *Quality of service functional requirements for the IMT-2020 network*.
+- [b-ETSI TS 128 530] Technical Specification ETSI TS 128 530 V16.2.0 (2020), *5G; Management and orchestration; Concepts, use cases and requirements (3GPP TS 28.530 version 16.2.0 Release 16)*.
+- [b-3GPP TS 23.501] 3GPP TS 23.501 (2019), *3rd Generation Partnership Project – Technical Specification Group Services and System Aspects – System architecture for the 5G System (5GS); Stage 2*. [b-3GPP TS 28.552] 3GPP TS 28.552 (2020), *3rd Generation Partnership Project – Technical Specification Group Services and System Aspects – Management and orchestration; 5G performance measurements*.
+- [b-GSMA NG.116] GSM Association Official Document NG.116 (2020), *Generic network slice template*, Version 4.0.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3d074b24082ac67647a309b295873add13858e6c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d4877b8603ae084d0cec61919ff2aa573d3908e6ae1ee2d2d94cb3fcdf4e135c
+size 74348
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5f77e0f7bee2f96ba6e6fce988ab87e460e4cd86
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:df3c53d15b96fc364fbbee20b3853dd15976ba4af6b13067025b25dd03245989
+size 50259
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..956b9c5e745c37782050e38526d3a9f6ba253e88
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5793a44ffdadd039928e2f9fe6daae06_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6889f03e4510479966b942d998183e23384dc848b1f0dd4e33137957361db46a
+size 22445
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..45065b1911d4ff52d6f8e051d8062063614fdb8a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:58b7d5b1940aaeb64a69505db82c66cd9947aa6031a4ede80488d2138abf302a
+size 99341
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d658c35cb73d93c5afb8531d3e85a8ff86ac2ed7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7111715d504881f57683031076c557119f3d7def13b8f9d997934909be1f7c34
+size 19873
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..66334317f2a1a03ef942a3a59ed45ce456bb6fc4
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:556bc4245be7a574519f3f5123b501f1a8f877a505d998fe973e7f7d96b4c297
+size 81219
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a24e89a6fe9bb70c83f8bf5202baba95_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a24e89a6fe9bb70c83f8bf5202baba95_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2743c27e144230b1b93e4744005be1acce763638
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a24e89a6fe9bb70c83f8bf5202baba95_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cdaa89ae8f30abaf77ef087d554d9db10b93791b438197e228f4f864f1ba08bd
+size 62003
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..526df2d2840d40c8ea4d7cccad6445ce5285cf7c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d27cdcb863992ee2e03fb51434f5d58a1b229788ed377d55a0f61124988de92b
+size 61735
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..69be8f94248eb9ce7293b81d694c15920ace5a30
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:89962d6a2df91f3afe440bf579279c75577588d5d3fd187f16a9bfc3de956afb
+size 47418
diff --git a/marked/Y/T-REC-Y.3161-202312-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4ae14088ea05de82d5c7c05db353deae6d951d05
--- /dev/null
+++ b/marked/Y/T-REC-Y.3161-202312-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e400f225ab612c94d0dee561f3e636bc3dc4eaea9ce92ec38b9e0c6e887213ff
+size 95632
diff --git a/marked/Y/T-REC-Y.3168-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3168-202512-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b16a9f60d14335d6d5f903dadfe44de583ce1d8d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aed841a2c2f2d81db976abf7c170e9fc00599175a6c4ea2f8bbcd8bea5d988a2
+size 41659
diff --git a/marked/Y/T-REC-Y.3168-202512-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9234e63cec820f30530a8b6f1aff7d5e2baf7d34
--- /dev/null
+++ b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6b03793d021510e5c812439cbbc9e29f1ebb4f9f2f189be84a380a00d261186f
+size 65305
diff --git a/marked/Y/T-REC-Y.3168-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ce61cec46c0a2efe1e9baad246a9669110063031
--- /dev/null
+++ b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:78577d81114dd832b37e3b972fb6391d6a870cd49b939e219f853f9de36b8800
+size 103416
diff --git a/marked/Y/T-REC-Y.3168-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..878c4a7c927bd9bdd6bfc40507ef725cc7c90bd3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3168-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c07a2dd174f98d48c74f5a0ebdf81ee4b9f28845661b3ba87980719524ff89aa
+size 62141
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8ffdbba8bec702b70d7e36faac568c82e0d860df
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:67877b6ab62129eef3478aaeeff5945953d638db5f8a401be5d2f00266539432
+size 55842
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..733a24d507482d38756bf73d1b3585f84420a6e0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/11edb7fcedf09ac6a817f8d7b8c61eec_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ab566686e0c98c8b40bd31ef04ba61e01a78bf72ffe92b99b267ad268d452eb4
+size 47077
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4f2e8c27f82e412cf2741c694624150b72570a81
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/1439cb942d9e363bbb3161b5540dd8c6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e665c20a304f39ea2832b94082ca8cf28859baf52cafa3a607a85a69327d5bde
+size 54446
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94d45ee0d7450a0c276bffad33306ce1ec96de62
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c981deef08fa0ff69264e0a06c61f5dd291a362fb37303b3216e33a0ba5040e9
+size 5841
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/17cd95aa220e50963bf6eb9818e33163_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/17cd95aa220e50963bf6eb9818e33163_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3685824cceb910b570daba9548e91cdda5dbdf39
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/17cd95aa220e50963bf6eb9818e33163_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f2d87695133565ea972542d8ae0ef16f6b79c6b6890fcf54d00c1e4b9fbdac94
+size 24947
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/2cde062fd82833415971a8bd1a2cafab_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/2cde062fd82833415971a8bd1a2cafab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..882b003ce1780dcc62ee722708360ddd9aa63008
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/2cde062fd82833415971a8bd1a2cafab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3d7fd1d1a3d13c606f23a8f07d748e8685d2f4e88d3874e9987bd2a4064b18dd
+size 84954
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/366a77fdefb0097b3289b4a011911390_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/366a77fdefb0097b3289b4a011911390_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b4096e49a934020b8079c0ef08ad3ae9c0851101
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/366a77fdefb0097b3289b4a011911390_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:29ec814711f257da8f3bdbea4d2e63653ecbbc800629b632e4450d10b28cb44b
+size 56057
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7a14dfc04d3f078f82302abee8fdbf9b492d2c81
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f14eb28395ed95a7f2308b5e39734a0295dae0d87257f3c5687c0d25ee6b73fc
+size 39482
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5590917d5b83300061f56e61fc6f6d24019894c6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/6f31cdb576d2f15c35c3f266e5f59211_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ffe14c9fdd0476bcf27134234c5eea7ea78dc56620e3b0f8c8068859fdf57241
+size 15907
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e7765b1d05ab23007851b670c343069921db3e61
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a8ef4adcded6b855e2daaa30a437820e7e9a9bab56fdaa118c3112dd75bb7feb
+size 143998
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/744acfe8d4e31bcf03f95714c2f6e567_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/744acfe8d4e31bcf03f95714c2f6e567_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..29e9b5fe6bf96ae1bafd0ce8e40ecc0d5c509e27
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/744acfe8d4e31bcf03f95714c2f6e567_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5e792e63b88100a5a5eadbf5ccb500bc192f7b36c277fb42a3e5305d21d7fc1d
+size 41055
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e792cdaa1f6c2dac5fe1b203202073021ec15edb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/79e1709a7317ead45379cbb8ff3ba802_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:54ace5e615836ff0bfd51687ab922b2a51ae55520418e3a311bc874eb790a750
+size 127573
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3cd5ece818aaff59bf736fe18862f6b33ae5bcb6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:38cacc338b6c42a911be0f0e854960a7d540a05dd9b9a73f6ce937d41d7084a9
+size 54415
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8f12dd79b93d1c955ab13f9bf09a5530ec52e272
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f171d127e66dcc75f6e3709eaab97ee7725d99abea571e0438534b127a3b700f
+size 42969
diff --git a/marked/Y/T-REC-Y.3180-202202-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..aef78e6d6349477b891ec9b38db8c20ca665f83a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3180-202202-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:186f2d3de50d11ca0d461274ce3696d5a7d3d1654b17592f690b655414d59c2d
+size 56618
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2fbc9784f13575dd160539e0758d5208d0f02db3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/00504fc688ebcf131ccbeff94dfc9939_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:33e4ff9635f38a4d4c95db2252077031dec814ad03416a077b62cbbfca18098d
+size 29588
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b45724c34f059a25c2d3c335ec0687d647547980
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e48802bee3783411b6bdbfcdfe63108def67255ae0d3387d35602fb6b3402eff
+size 5722
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/5d3455c6c2a37cb3aff761fedeb8644e_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/5d3455c6c2a37cb3aff761fedeb8644e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..02f2720482b4e60a5323fc5ed09fca480ccbe95e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/5d3455c6c2a37cb3aff761fedeb8644e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:57e6bc6bc339c3b72ee0faf1e60584fd17895322853dc4fab1ae0b5c37228d17
+size 109343
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b154e96a24c7232ae2b581ad34ce58fdaf960747
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/7ae836e598020d937ed1478c2ef13025_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9bd25c88e68d5283c14db6b318faae11b77a1d59fd1a7fdfe74d415cc31eeaf4
+size 174036
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f77a207dca2a4e37d462274af66b6077622f103c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8307f6b04df072c9332f9987e034272c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e1f026200516f422e97ca4dace405dd29c86ee6320b8f7c78180d5539e2ee196
+size 10315
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6e24e4472aad3cf2328542a275c9369c61f4cc30
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1e63e1f26a6a9964755876373759e6842982a5ffcdaca0adfa0582879a7252a9
+size 140431
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/ae53f90bb87d6d09e2d6b5278d7c338f_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/ae53f90bb87d6d09e2d6b5278d7c338f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f36bb28942c7c163b3a8489f08007970b5fdf3a5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/ae53f90bb87d6d09e2d6b5278d7c338f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:785d2c87c4236b9191aefc58018e341c4c7a464d14104fc6d25e019797430917
+size 97219
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6cbb113eecc7563f6312472967a402c39316065e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/c914f51f4427bc672dd0526cfc90ebe9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0c800a4d27edce94cb23b3ce1b0038da0702b7733c31d5c24f58246c8316a4bf
+size 84374
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dadf592df3be2b27ff6c4c02ed574a4d9771fccb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:76c0a36a5d838ab06d842e8f9137613add4dc3925de0432be7fce7d898259ab5
+size 91544
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5e0897a701c6dff208ff30c8d10761911b6df107
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/dfe556fea00682b09a59427aaf72051c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4aebd4ad55ae9286dbde795e0b09eaff5e466f8f35131efc9b5d47143acb8873
+size 120572
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f050445a87a9b48b4ac07c6fcb2e8480_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f050445a87a9b48b4ac07c6fcb2e8480_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..63af7fac27f1322ebf5d0ace5db3906c0de0efc8
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f050445a87a9b48b4ac07c6fcb2e8480_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a6960abe750934e59ee88c9ad4abc8cd973f846846efb452ae81e60f775daafe
+size 71352
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f57c7b37d7a05a99618104f390089f03_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f57c7b37d7a05a99618104f390089f03_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..01b8f3ab15cc2bf9575512b762f8aab3a146bdc2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/f57c7b37d7a05a99618104f390089f03_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fb8fc025b2eb143381991cfaadfbcfba728a9dec489723bcda860a6e427b8716
+size 96036
diff --git a/marked/Y/T-REC-Y.3182-202209-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d17f9d373673f093520584215563f1c8b4d0be41
--- /dev/null
+++ b/marked/Y/T-REC-Y.3182-202209-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0a156890510a3e5f50de0bc6f0ca6dfb992f6b472f40e6370060fcdd7db7ca36
+size 100890
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/21ad58fee90f2be50708ff541d225507_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/21ad58fee90f2be50708ff541d225507_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..50b728bf12934ced69b33825975c62a1533f3a36
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/21ad58fee90f2be50708ff541d225507_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ce059c1d0503e6c0c64076cde685eb740e62bd39557109f5d85fb46a40f27491
+size 59581
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0370cca94548bc5ba63f48aff76b926d2b626f74
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cdc931c60f5a6858102c29af12b5da379cdd8dd49be11a42d5617986c2afc741
+size 7140
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/4e4be0bd8b235167902f2c03e41da651_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/4e4be0bd8b235167902f2c03e41da651_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..64f281bf14f37803fa85b30f396525a402bf217e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/4e4be0bd8b235167902f2c03e41da651_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:73cb1b92fde931a0b69e8f1daef7a7bf49c81f08a66833f8010161b97ce8ea1e
+size 123886
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f498ea3702e5c479f4b95759d434cb858a73b1cd
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0bbd50e44844a9e452f8dc9b9df2aa8250a78a89bc368513a46a72c59c4ede64
+size 42976
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..89c7d3f0e2325b429036a2cfe58e51afb0974432
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/9c6461e1e94afae4dec455e69a2ce152_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0b72ddf508c7bef8062b43bfa4f594bceabda368a55411e842f58d73ecb261b5
+size 50625
diff --git a/marked/Y/T-REC-Y.3188-202510-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..73958602a2f59d307b9b12b30913f2c721770718
--- /dev/null
+++ b/marked/Y/T-REC-Y.3188-202510-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:57b8ea3200a53aeee5246555ef9a349860976f312adf1c0ac284c8aac214f2e7
+size 54973
diff --git a/marked/Y/T-REC-Y.3321-201506-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.3321-201506-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c564836eb7d8b6bf48d757457dec2b48d3fc7b4c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aee40e5a34807da5200948246738058e77e5bcbfe90f4fa63d983a075db6ed8d
+size 77787
diff --git a/marked/Y/T-REC-Y.3321-201506-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..5f64be34e876a48bfe61a1503a8124539fe18c1b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3321-201506-I_PDF-E/raw.md
@@ -0,0 +1,520 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.3321
+
+(06/2015)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Future networks
+
+# --- **Requirements and capability framework for NICE implementation making use of software- defined networking technologies**
+
+Recommendation ITU-T Y.3321
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+# GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## **FUTURE NETWORKS** **Y.3000–Y.3499**
+
+### **CLOUD COMPUTING** **Y.3500–Y.3999**
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.3321
+
+# Requirements and capability framework for NICE implementation making use of software-defined networking technologies
+
+## Summary
+
+Recommendation ITU-T Y.3321 specifies the requirements and capability framework of S-NICE (Software-defined Network Intelligence Capability Enhancement).
+
+NICE (see Recommendation ITU-T Y.2301) is an enhanced next generation network (NGN) (i.e., an evolved version of NGN) supporting extended or additional intelligent capabilities for provisioning of services according to requirements of users and application providers. S-NICE is a specific implementation of NICE, making use of software-defined networking technologies, and its key objective is the identification of the NICE implementation requirements when relevant NICE features are supported by software-defined networking technologies.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3321 | 2015-06-13 | 13 | 11.1002/1000/12523 |
+
+## Keywords
+
+Network intelligence capability enhancement, NICE, SDN, software defined networking.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2015
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|------------------------------------------------------------------------------------------------|-------------|
+| 1 Scope..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 3 |
+| 5 Conventions ..... | 3 |
+| 6 Requirements of software-defined NICE ..... | 3 |
+| 6.1 Introduction to S-NICE ..... | 3 |
+| 6.2 Requirements of service control..... | 4 |
+| 6.3 Requirements of open environment..... | 4 |
+| 6.4 Requirements of content and context analysis ..... | 4 |
+| 6.5 Requirements of policy control ..... | 5 |
+| 6.6 Requirements of traffic scheduling ..... | 5 |
+| 6.7 Requirements of access and core transport ..... | 6 |
+| 6.8 Requirements for support of virtualized network and virtualized network functions ..... | 6 |
+| 7 The capability framework for software-defined NICE..... | 6 |
+| 7.1 Overview of the capability framework..... | 6 |
+| 7.2 The S-NICE orchestration capabilities at the service layer..... | 7 |
+| 7.3 The S-NICE controller capabilities at the transport layer ..... | 8 |
+| 7.4 The S-NICE infrastructure capabilities at the transport layer ..... | 9 |
+| 8 Security considerations..... | 9 |
+| Appendix I – Differences between NICE capabilities and S-NICE capabilities ..... | 11 |
+| Bibliography..... | 15 |
+
+
+
+## Recommendation ITU-T Y.3321
+
+# Requirements and capability framework for NICE implementation making use of software-defined networking technologies
+
+## 1 Scope
+
+This Recommendation provides the requirements and capability framework for software-defined network intelligence capability enhancement (S-NICE). S-NICE is a specific implementation of NICE [ITU-T Y.2301] making use of software-defined networking technologies. NICE being an evolved version of NGN, S-NICE supports the intelligent features (five major features) of NICE and makes usage of software-defined networking technologies. This Recommendation specifies the requirements and capabilities of S-NICE at the next generation network (NGN) service and network stratum.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ITU-T Y.2301] Recommendation ITU-T Y.2301 (2013), *Network intelligence capability enhancement – Requirements and capabilities*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 application** [b-ITU-T Y.101]: A structured set of capabilities which provide value-added functionality, supported by one or more services.
+
+**3.1.2 application provider** [b-ITU-T Y.2012]: A general reference to a provider that offers applications to the customers making use of the service capabilities provided by the NGN.
+
+**3.1.3 content** [b-ITU-T H.780]: A combination of audio, still image, graphic, video, or data.
+
+NOTE – A variety of formats are classified as "data" (e.g., text, encoded values, multimedia description language introduced by [b-ITU-T H.760]).
+
+**3.1.4 context** [b-ITU-T Y.2002]: The information that can be used to characterize the environment of a user.
+
+NOTE – Context information may include where the user is, what resources (devices, access points, noise level, bandwidth, etc.) are near the user, at what time the user is moving, interaction history between person and objects, etc. According to specific applications, context information can be updated.
+
+**3.1.5 context awareness** [b-ITU-T Y.2201]: The capability to determine or influence a next action in telecommunication or process by referring to the status of relevant entities, which form a coherent environment as a context.
+
+**3.1.6 identity** [b-ITU-T Y.2720]: Information about an entity that is sufficient to identify that entity in a particular context.
+
+**3.1.7 identity management (IdM)** [b-ITU-T Y.2720]: Set of functions and capabilities (e.g., administration, management and maintenance, discovery, communication exchanges, correlation and binding, policy enforcement, authentication and assertions) used for:
+
+- assurance of identity information (e.g., identifiers, credentials, attributes);
+- assurance of the identity of an entity (e.g., users/subscribers, groups, user devices, organizations, network and service providers, network elements and objects, and virtual objects); and
+- enabling business and security applications.
+
+**3.1.8 media** [b-ITU-T Y.2012]: One or more of audio, video, or data.
+
+**3.1.9 media stream** [b-ITU-T Y.2012]: A media stream can consist of audio, video, or data, or a combination of any of them. Media stream data conveys user or application data (i.e., a payload) but not control data.
+
+**3.1.10 network intelligence capability enhancement (NICE)** [ITU-T Y.2301]: An enhanced NGN supporting some intelligent capabilities for the provisioning of services according to requirements of users and application providers. These intelligent capabilities (termed as "NICE capabilities") enable operators to assign and dynamically adjust specific network resources based on the requirements, as well as support interfaces for users and applications enabling on demand resource and service provision.
+
+**3.1.11 next generation network (NGN)** [b-ITU-T Y.2001]: A packet-based network able to provide telecommunication services and able to make use of multiple broadband, QoS-enabled transport technologies and in which service-related functions are independent from underlying transport-related technologies. It enables unfettered access for users to networks and to competing service providers and/or services of their choice. It supports generalized mobility which will allow consistent and ubiquitous provision of services to users.
+
+**3.1.12 service** [b-ITU-T Y.2091]: A set of functions and facilities offered to a user by a provider.
+
+**3.1.13 software-defined networking (SDN)** [b-ITU-T Y.3300]: A set of techniques that enables to directly program, orchestrate, control and manage network resources, which facilitates the design, delivery and operation of network services in a dynamic and scalable manner.
+
+**3.1.14 user** [b-ITU-T Y.2201]: A user includes end user [b-ITU-T Y.2091], person, subscriber, system, equipment, terminal (e.g., FAX, PC), (functional) entity, process, application, provider, or corporate network.
+
+### **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following terms:
+
+**3.2.1 S-NICE controller capabilities:** Capabilities providing a means to control the S-NICE infrastructure capabilities (such as data transport and processing on per flow basis) requested by applications.
+
+**3.2.2 S-NICE infrastructure capabilities:** Capabilities which are controlled by the S-NICE controller capabilities to perform actions according to applications' requirements.
+
+**3.2.3 S-NICE orchestration capabilities:** Capabilities which coordinate with applications and S-NICE controller capabilities to provide software-defined control and management of network resources and users, as well as service creation and provisioning.
+
+**3.2.4 virtualized network:** In this Recommendation, a network that makes use of virtualization technologies. It enables the abstraction of network resources such as creation of logically isolated virtual networks over a single physical network, and aggregation of multiple network resources as a single network resource.
+
+**3.2.5 virtualized network function:** In this Recommendation, a network function whose functional software is decoupled from hardware, and runs on virtual machine(s).
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|---------------------------------------------|
+| API | Application Programming Interface |
+| IdM | Identity Management |
+| IoT | Internet of Things |
+| NGN | Next Generation Network |
+| NICE | Network Intelligence Capability Enhancement |
+| OAM | Operation, Administration and Maintenance |
+| QoS | Quality of Service |
+| RACF | Resource and Admission Control Functions |
+| S-NICE | Software-defined NICE |
+| SDN | Software-defined Networking |
+| SUP | Service User Profile |
+
+## **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this document is to be claimed.
+
+# **6 Requirements of software-defined NICE**
+
+### **6.1 Introduction to S-NICE**
+
+Software-defined NICE (S-NICE) is a specific implementation of NICE [ITU-T Y.2301] making use of software-defined networking (SDN) concept and technologies. NICE is an evolved version of NGN. S-NICE supports the intelligent features (five major features) of NICE and is enhanced by taking advantage of SDN concept and technologies. Some capabilities of NICE are considered in S-NICE with different implementation approaches and enhancements.
+
+In S-NICE, the capabilities of NICE such as the service control capability, the policy control capability, and the traffic scheduling capability, can be redesigned and deployed based on SDN concept and technologies.
+
+Major features supported by SDN technologies include the decoupling of control and data planes, the logical centralization of network intelligence and status, and the abstraction of the underlying network infrastructure for the applications. S-NICE adopts the major features of SDN technologies to provide highly scalable and flexible control as well as programmable and automatic interaction between network and applications.
+
+In S-NICE, except for the content and context analysis capability, the transport control layer capabilities are centralized as controller capabilities (the so-called S-NICE controller capabilities), which maintain a global view of the underlying S-NICE infrastructure. As a result, the S-NICE infrastructure appears to the S-NICE controller capabilities as abstracted logical networks.
+
+In S-NICE, the transport layer capabilities are regarded as infrastructure capabilities (the so-called S-NICE infrastructure capabilities), which no longer need to understand and process various protocol standards as in traditional NGNs or NICEs but merely accept instructions from the centralized S-NICE controller capabilities.
+
+S-NICE also uses SDN related protocols to identify network traffic based on pre-defined match rules that can be statically or dynamically programmed by the S-NICE controller capabilities. Since SDN technologies allow the control elements of a network to be programmed, S-NICE provides extremely small granular control of the network to enable the network response to real-time changes for applications and users.
+
+Appendix I provides a summary of both NICE and S-NICE capabilities and shows their differences.
+
+### **6.2 Requirements of service control**
+
+In NICE, the service control capability is required to receive and transfer the application requests concerning policy control and traffic scheduling to the transport layer or to receive and transfer transport related information to the service layer. In addition, the service control capability is also required to provide resource control, registration, authentication, and authorization capabilities at the service level.
+
+In S-NICE, the service control capability is one of the S-NICE orchestration capabilities, and it is required to support "on demand" configuration in order to provide "dynamic" resource control, registration, authentication, and authorization capabilities at the service level, upon request of applications. For example, if a user asks for high quality of service (QoS) level during an ongoing service session of an application when the user feels unsatisfied of the delivered QoS, then the service control capability of S-NICE selects the appropriate S-NICE controller capabilities to adjust the network resources in order to fulfil the user's requirement immediately.
+
+### **6.3 Requirements of open environment**
+
+In NICE, the open environment capability supports the invocation by developers and applications of NICE capabilities, such as the policy control capability and the traffic scheduling capability, via standard application programming interfaces (APIs).
+
+In S-NICE, the open environment capability is one of the S-NICE orchestration capabilities, and it is required to enable developers and applications to take full advantage of the S-NICE controller capabilities, such as virtualized network information abstraction, S-NICE controller(s) selection, and status monitoring. It is also required to support openness of content and context analysis information to developers and applications. Moreover, it is required to provide APIs to developers and applications for openness of S-NICE controller capabilities.
+
+### **6.4 Requirements of content and context analysis**
+
+In NICE, the content and context analysis capability receives the awareness related information from the content and context detection capability and deeply analyses this information. The content and context analysis capability supports processing and storage of content and context information and distributes user traffic analysis results and network status analysis results to the requestor of content and context information, such as the policy control capability and the traffic scheduling capability. Moreover, the interaction between the NICE content and context detection capability and the NICE content and context analysis capability is based on management configuration.
+
+In S-NICE, the content and context analysis capability is required to provide user traffic analysis results and network status analysis results to the S-NICE controller capabilities and the S-NICE orchestration capabilities. The analysis results include not only user traffic, users' service preferences and network status, but also abstracted information of physical and logical transport networks. Based
+
+on the analysis results, the S-NICE controller capabilities and the S-NICE orchestration capabilities configure, manage, secure, and optimize the network resources.
+
+In S-NICE, the transfer of all the detected information from the content and context detection capability to the content and context analysis capability, and the transfer of detection rules from the content and context analysis capability to the content and context detection capability are required to support SDN related protocols.
+
+### **6.5 Requirements of policy control**
+
+In NICE, the policy control capability receives analysis results regarding user, traffic, and network information from the content and context analysis capability while it also receives the application's bandwidth and QoS assignment requirements from the service control capability and the service user profile (SUP) capability. The policy control capability makes policy information decisions and updates, and then sends the results of these policy decisions and updates to the policy enforcement capability. The policy control capability also makes decisions regarding network resource and admission control, supports unified policy database and consistent policies definitions, and supports a variety of access and core networks within a general resource control framework.
+
+In NICE, the policy enforcement capability is based on pre-defined rules and receives policy control requirements from the policy control capability.
+
+In S-NICE, the policy control capability is one of the S-NICE controller capabilities. The control policies are not only concerning access control, bandwidth management, and QoS level, but also security, reliability, energy usage, network monitoring and statistics, etc. The policy control capability is also required to support additional service layer APIs in order to allow on-demand resource allocation and self-service provisioning to application providers and users. The policy control capability is enhanced in S-NICE, so that the policy decisions transferred to the policy enforcement capability of S-NICE are straightforward instructions.
+
+In S-NICE, the policy enforcement capability no longer needs to understand and process various protocol standards as in traditional NGNs or NICEs, but merely accepts instructions from the policy control capability of S-NICE and performs actions such as packet forwarding and packet dropping. The transfer of the policy control decisions between the policy control capability and the policy enforcement capability is required to support SDN related protocols.
+
+### **6.6 Requirements of traffic scheduling**
+
+In NICE, the traffic scheduling capability receives the application's traffic delivery requirements from the service control capability and analysis results from the content and context analysis capability. Then, it establishes traffic scheduling rules based on these results. The traffic scheduling capability of NICE includes route and delivery node selection or adjustment based on traffic localization, network status, etc.
+
+In NICE, the traffic scheduling enforcement capability is based on pre-defined rules, and receives traffic scheduling rules from the traffic scheduling capability.
+
+In S-NICE, the traffic scheduling capability is one of the S-NICE controller capabilities. It includes traffic engineering based on multicast routing optimization, processor and storage optimization, etc. The traffic scheduling capability is also required to support additional service layer APIs to allow on-demand resource allocation and self-service provisioning to application providers and users. The traffic scheduling capability is enhanced in S-NICE, so that the traffic scheduling rules transferred to the traffic scheduling enforcement capability of S-NICE are straightforward instructions.
+
+In S-NICE, the traffic scheduling enforcement capability no longer needs to understand and process various protocol standards as in traditional NGNs or NICEs, but merely accepts instructions from the traffic scheduling capability of S-NICE and performs actions such as input and output port selection and route selection. The transfer of the traffic scheduling rules between the traffic scheduling
+
+capability and the traffic scheduling enforcement capability is required to support SDN related protocols.
+
+### **6.7 Requirements of access and core transport**
+
+In NICE, the access and core transport capabilities provide the connectivity for the components of the NICE provider's infrastructure. They provide support of application data delivery, as well as the delivery of control and management information.
+
+The access and core transport capabilities requirements of S-NICE are aligned with the requirements of NICE [ITU-T Y.2301], and have some enhancements. In S-NICE, the access and core transport capabilities are part of the S-NICE infrastructure capabilities, and they are required to perform the decisions made by the S-NICE controller capabilities. In addition, the access and core transport capabilities are required to support SDN related protocols.
+
+### **6.8 Requirements for support of virtualized network and virtualized network functions**
+
+S-NICE is required to support virtualized network and virtualized network functions, which decouple network function software from hardware, in order to provide various capabilities including fast network function deployment, abstraction of transport, computing and storage resources, dynamic virtual and physical resource management, automatic fault detection and recovery, and on-demand system scalability.
+
+S-NICE is required to support the coexistence of virtualized network functions and non-virtualized network functions by virtualizing some network functions while still having some other non-virtualized functions in the same network. S-NICE is also required to support the coexistence of a virtualized network and a non-virtualized network by deploying a new complete virtualized network which can be used for specific services and devices (e.g., Internet of Things (IoT) applications and devices) or for traffic exceeding the capacity of the non-virtualized network while still having the non-virtualized one.
+
+## **7 The capability framework for software-defined NICE**
+
+### **7.1 Overview of the capability framework**
+
+S-NICE capabilities are aligned with, and enhance, the NICE capabilities as described in [ITU-T Y.2301].
+
+Making use of SDN concept and technologies, the S-NICE capability framework differs from the NICE capability framework. Figure 1 provides the capability framework overview of S-NICE.
+
+
+
+CC = content and context
+
+Y.3321(15)\_F01
+
+Figure 1 – Capability framework overview of S-NICE. The diagram illustrates a three-layer architecture: Service layer, Transport layer, and S-NICE infrastructure. The Service layer includes Self-operated application and Third party application, both connected via API to the Open environment, Service user profile, Service control, and S-NICE orchestration. The Transport layer includes the S-NICE controller (Policy control, Traffic scheduling) and CC analysis. The S-NICE infrastructure includes CC detection, Policy enforcement, Traffic scheduling enforcement, and Access and core transport. A User is shown interacting with the Service control and support capabilities, Transport control capabilities, and Transport capabilities. The diagram also includes a legend: CC = content and context.
+
+**Figure 1 – Capability framework overview of S-NICE**
+
+At the service layer, the S-NICE orchestration capabilities consist of the service control capability and the open environment capability, and interact with the SUP capability.
+
+The transport layer has S-NICE controller capabilities (named "S-NICE controller", for brevity, in Figure 1), which consist of the policy control capability and the traffic scheduling capability of S-NICE. The transport layer also has S-NICE infrastructure capabilities which support the access and core transport capability with the requirements to support SDN related protocols. Meanwhile, the S-NICE infrastructure capabilities support the content and context detection capability, the policy enforcement capability, and the traffic scheduling enforcement capability of S-NICE.
+
+Although the separation of network control and transport applies in both NICE and S-NICE, S-NICE extends this concept further by taking advantage of SDN technologies. The interaction mechanisms and interfaces of S-NICE are different from those of NICE. In S-NICE, the interfaces between applications and the S-NICE orchestration capabilities, the interfaces between S-NICE controller capabilities and the S-NICE infrastructure capabilities, and the interfaces between the S-NICE orchestration capabilities and the S-NICE controller capabilities are required to use SDN related protocols while in NICE this usage is not required.
+
+### 7.2 The S-NICE orchestration capabilities at the service layer
+
+In NICE, the NICE provider interconnects with third-party applications as well as self-operated applications via the open environment capability and the service control capability.
+
+In S-NICE, the open environment capability and the service control capability of NICE are both provided by the S-NICE orchestration capabilities. In addition, the S-NICE orchestration capabilities are required to provide interfaces to the S-NICE controller capabilities which are located in the transport control layer.
+
+The S-NICE orchestration capabilities are required to connect with all the S-NICE controllers and offer access to all the controllers' capabilities for third-party and self-operated applications.
+
+NOTE – The notion of S-NICE controller will be introduced in clause 7.3.
+
+The S-NICE orchestration capabilities also allow applications to not have to deal with each S-NICE controller one by one, they can be aware of and access the capabilities of all S-NICE controllers. Moreover, the orchestration capabilities are required to monitor the network and notify the applications when applicable.
+
+The orchestration capabilities are required to support, but are not limited to, the following features:
+
+- access to open environment for applications including content and context analysis openness, policy control openness, and traffic engineering openness;
+- virtualized network information provision to applications, such as provision of virtual network topology, route path setting and delivery node selection [ITU-T Y.2301];
+- monitoring of S-NICE controllers' status;
+- selection of the S-NICE controller capabilities;
+- service creation and provisioning based on applications' requirements;
+- orchestration of the S-NICE controller capabilities based on applications' requirements;
+- orchestration of the S-NICE controller capabilities based on virtualized network and physical network status;
+- conflict management and negotiation to maintain policy consistency among different capabilities of a S-NICE controller, among different S-NICE controllers, and between S-NICE controller capabilities and S-NICE infrastructure capabilities.
+
+### **7.3 The S-NICE controller capabilities at the transport layer**
+
+The S-NICE controller capabilities are required to provide the transport control capabilities such as the policy control capability and the traffic scheduling capability. Because the policy control capability and the traffic scheduling capability are enhanced in S-NICE so that the policy decisions and the traffic scheduling rules transferred to the S-NICE infrastructure capabilities are straightforward instructions, the S-NICE infrastructure capabilities no longer need to understand and process various protocol standards as in traditional NGNs or NICEs, but merely accept instructions from the centralized S-NICE controller capabilities.
+
+NOTE 1 – From an implementation point of view, the policy control capability and the traffic scheduling capability of S-NICE are implemented within a single S-NICE controller, and because of the limitation of geographical reasons and processing capabilities, multiple S-NICE controllers may be required to control different network regions.
+
+The S-NICE controller capabilities are required to connect with the S-NICE orchestration capabilities and the S-NICE infrastructure capabilities by using SDN related protocols. The S-NICE controller capabilities are required to control the S-NICE infrastructure capabilities in order to meet the applications' requirements.
+
+The S-NICE controller capabilities are required to support, but are not limited to, the following features:
+
+- connection with the S-NICE orchestration capabilities and with the S-NICE infrastructure capabilities;
+- policy control and network resource management based on infrastructure information;
+
+NOTE 2 – The S-NICE controller capabilities can obtain information from network links and nodes to compute network topology information. The S-NICE controller capabilities can also obtain resource usage information and statistics from the network management system and the content and context analysis capability;
+
+- policy control based on application requirements provided by the S-NICE orchestration capabilities, information from network resource management, and analysis results from the content and context analysis capability;
+
+- traffic scheduling based on information provided by network resource management, application requirements provided by the S-NICE orchestration capabilities, and analysis results from the content and context analysis capability;
+- receiving results of content and context analysis of infrastructure and applications, and performing policy control and traffic scheduling based on these results. The S-NICE controller capabilities are required to be aware of physical and virtual network topology, traffic flows and information of the infrastructure;
+- cooperation with the network management system to provide operation, administration and maintenance (OAM) and alarm information;
+
+NOTE 3 – The S-NICE controller capabilities can provide additional support for the provisioning of OAM and alarm information, however functional overlapping between S-NICE controller capabilities and the network management system needs to be avoided.
+
+- cooperation between physical network and virtualized network;
+- connection with other S-NICE controller capabilities;
+- monitoring of physical network and virtualized network.
+
+### **7.4 The S-NICE infrastructure capabilities at the transport layer**
+
+The S-NICE infrastructure capabilities implement the actions decided by the S-NICE controller capabilities. The S-NICE infrastructure capabilities include the policy enforcement capability, the traffic scheduling enforcement capability, the content and context detection capability, and the access and core transport capability of S-NICE.
+
+The S-NICE infrastructure capabilities are required to support, but are not limited to, the following features:
+
+- communication with the S-NICE controller capabilities;
+- provision of the infrastructure information (e.g., network topology information, flow information, service routing information) to the relevant S-NICE controller capabilities based on requests;
+
+NOTE 1 – Different S-NICE controller capabilities may request different infrastructure information.
+
+- forwarding of traffic on a per flow basis;
+- forwarding of traffic while maintaining policy consistency among the S-NICE controller capabilities, the S-NICE infrastructure capabilities and the applications;
+- isolation and virtualization of different parts of the network;
+
+NOTE 2 – For example, many access transport networks can be isolated from each other and virtualized as one network.
+
+- reception of policy decisions from the S-NICE controller capabilities and enforcement of these policy decisions (e.g., by packet forwarding and processing);
+- reception of traffic scheduling rules from the S-NICE controller capabilities and enforcement of these traffic scheduling rules (e.g., by transport node selection and path selection).
+
+## **8 Security considerations**
+
+The security requirements of S-NICE are aligned with the security requirements of NICE [ITU-T Y.2301] with the following additional requirements:
+
+- enhanced security of the SDN controller(s) which incorporates the transport control capabilities, because the logically centralized controller could be a single point of failure, or a target of malicious attacks;
+
+- secure mechanisms to authorize network configurations and operations such as routing path establishment or virtualized network function deployment, upon demand by services or applications;
+- mechanisms to provide network isolation for both virtualized and physical network resources, in order to protect the network from malware attacks, even when some components of the network have already been affected;
+- appropriate mechanisms to monitor abnormal situations, to detect and defend from attacks and to recover network components and their states for virtualized network and virtualized network functions.
+
+## Appendix I
+
+### Differences between NICE capabilities and S-NICE capabilities
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The following table shows the differences between NICE capabilities and S-NICE capabilities.
+
+NOTE – The capabilities listed in Table I.1 are respectively derived from [ITU-T Y.2301] and this Recommendation.
+
+**Table I.1 – Differences between NICE capabilities and S-NICE capabilities**
+
+| Capabilities group | | NICE capabilities | S-NICE capabilities |
+|--------------------------------|------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Service layer capabilities | SUP | The SUP capability of NICE is required to support: • SUP-FE in NGN [ITU-T Y.2012]; • Identity Management (IdM) [ITU-T Y.2720]. | The SUP capability of S-NICE is aligned with that of NICE. |
+| | Service control | The service control capability of NICE is required to support: • Service Control Functions in NGN [ITU-T Y.2012]; • receiving and transferring information allowing the identification of application data for policy control and traffic scheduling; • receiving and transferring information allowing the identification of applications and users; • receiving and transferring transport layer events (e.g., notifications of QoS modifications) reported by the transport layer to the service layer. | The service control capability of S-NICE is aligned with that of NICE with support of the following additional requirements: • "on demand" configuration in order to provide "dynamic" resource control, registration, authentication, and authorization. |
+| | Open environment | The open environment capability of NICE is required to support: • openness [ITU-T Y.2240]; • open access to a service creation environment [ITU-T Y.2240]; • self-operated applications' invocation of NICE capabilities. | The open environment capability of S-NICE is aligned with that of NICE with support of the following additional requirements: • openness of content and context analysis information to developers and applications; • openness of virtualized network information abstraction; • openness of S-NICE controller(s) selection and status monitoring. |
+| Transport control capabilities | Content and context analysis | The content and context analysis capability of NICE is required to support: | The content and context analysis capability of S-NICE is aligned with that |
+
+**Table I.1 – Differences between NICE capabilities and S-NICE capabilities**
+
+| Capabilities group | | NICE capabilities | S-NICE capabilities |
+|------------------------|-------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | context awareness requirements of NGN (clause 7.3 of [ITU-T Y.2201]); providing user traffic analysis results; providing information related to user's application data; providing network status analysis results. | of NICE with support of the following additional requirements: providing user traffic analysis results and network status analysis results to the S-NICE controller capabilities and the S-NICE orchestration capabilities; providing additional analysis results, including abstracted information of physical and logical transport layer networks; support of SDN related protocols. |
+| | Policy control | The policy control capability of NICE is required to support: functional requirements of RACF [ITU-T Y.2111]; intelligent assignment of bandwidth and QoS level according to: on-demand requirements from users via a user self-service portal; requirements from a third-party application provider or, possibly, NICE provider via open environment capabilities; the content and context analysis results. | The policy control capability of S-NICE is aligned with that of NICE with support of the following additional requirements: providing control policies concerning security, reliability, energy usage, network monitoring and statistics, etc.; translating policy decisions into straightforward instructions and transferring these instructions to the policy enforcement capability of S-NICE; support of SDN related protocols. |
+| | Traffic scheduling | The traffic scheduling capability of NICE is required to align with the requirements of NGN [ITU-T Y.2201] with support of the following additional requirements in terms of generation of traffic scheduling rules: traffic localization; selection of the traffic delivery network node; network status; intelligent routing based on route selection policy; network virtualization. | The traffic scheduling capability of S-NICE is aligned with that of NICE with support of the following additional requirements: traffic engineering based on multicast routing optimization, processor and storage optimization, etc.; translating traffic scheduling rules into straightforward instructions and transferring these instructions to the traffic scheduling enforcement capability of S-NICE; support of SDN related protocols. |
+| Transport capabilities | Content and context detection | The content and context detection capability of NICE is required to extract the following transport-related information: user location information; | The content and context detection capability of S-NICE is aligned with that of NICE with support of the following additional requirements: |
+
+**Table I.1 – Differences between NICE capabilities and S-NICE capabilities**
+
+| Capabilities group | | NICE capabilities | S-NICE capabilities |
+|---------------------------|--------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | | • user application data information; • application data statistics; • user terminal parameters; • network resource information; • access network related information. | • detecting abstracted information of physical and logical transport layer networks; • support of SDN related protocols. |
+| | Policy enforcement | The policy enforcement capability of NICE is required to support:
• policy enforcement requirements in [ITU-T Y.2111]; • enforcement of on-demand bandwidth and QoS levels in order to satisfy on-demand requirements from users and application providers; • enforcement of bandwidth and QoS levels based on content and context analysis results. | The policy enforcement capability of S-NICE is aligned with that of NICE with support of the following additional requirements:
• accepting instructions from the policy control capability of S-NICE and performing actions such as packet forwarding and packet dropping; • support of SDN related protocols. |
+| | Traffic scheduling enforcement | The traffic scheduling enforcement capability of NICE is required to support:
• enforcement of traffic scheduling based on traffic localization schemes; • enforcement of traffic scheduling based on optimal selection of delivery nodes; • enforcement of traffic scheduling based on intelligent route selection and adjustment based on routing policies; • enforcement of traffic scheduling based on resource allocation using network virtualization. | The traffic scheduling enforcement capability of S-NICE is aligned with that of NICE with support of the following additional requirements:
• accepting instructions from the traffic scheduling capability of S-NICE and performing actions such as input and output port selection as well as route selection; • support of SDN related protocols. |
+
+**Table I.1 – Differences between NICE capabilities and S-NICE capabilities**
+
+| Capabilities group | | NICE capabilities | S-NICE capabilities |
+|---------------------------|----------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | Access and core transport capabilities | The access and core transport capabilities of NICE are required to align with the transport requirements of NGN [ITU-T Y.2012], with support of the additional following optional requirement:
• cache and media stream delivery functions in transport nodes. | The access and core transport capabilities of S-NICE are aligned with that of NICE with support of the following additional requirements:
• support of SDN related protocols. |
+
+## Bibliography
+
+- [b-ITU-T H.760] Recommendation ITU-T H.760 (2009), *Overview of multimedia application frameworks for IPTV services.*
+- [b-ITU-T H.780] Recommendation ITU-T H.780 (2012), *Digital signage: Service requirements and IPTV-based architecture.*
+- [b-ITU-T Y.101] Recommendation ITU-T Y.101 (2000), *Global Information Infrastructure terminology: Terms and definitions.*
+- [b-ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN.*
+- [b-ITU-T Y.2002] Recommendation ITU-T Y.2002 (2009), *Overview of ubiquitous networking and of its support in NGN.*
+- [b-ITU-T Y.2012] Recommendation ITU-T Y.2012 (2010), *Functional requirements and architecture of next generation networks.*
+- [b-ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks.*
+- [b-ITU-T Y.2111] Recommendation ITU-T Y.2111 (2011), *Resource and admission control functions in next generation networks.*
+- [b-ITU-T Y.2201] Recommendation ITU-T Y.2201 (2009), *Requirements and capabilities for ITU-T NGN.*
+- [b-ITU-T Y.2240] Recommendation ITU-T Y.2240 (2011), *Requirements and capabilities for next generation network service integration and delivery environment.*
+- [b-ITU-T Y.2302] Recommendation ITU-T Y.2302 (2014), *Network intelligence capability enhancement – Functional architecture.*
+- [b-ITU-T Y.2720] Recommendation ITU-T Y.2720 (2009), *NGN identity management framework.*
+- [b-ITU-T Y.2770] Recommendation ITU-T Y.2770 (2012), *Requirements for deep packet inspection in next generation networks.*
+- [b-ITU-T Y.3011] Recommendation ITU-T Y.3011 (2012), *Framework of network virtualization for future networks.*
+- [b-ITU-T Y.3300] Recommendation ITU-T Y.3300 (2014), *Framework of software-defined networking.*
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/0019f09403376d6444ee323591fa2e98_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/0019f09403376d6444ee323591fa2e98_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ffcad88edb717b57b28c6bcfdd9180206321e13d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/0019f09403376d6444ee323591fa2e98_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1a874dc26f3cd9eacd836493545021b8ed8507b03bf66d6e586dce3b4885d515
+size 39739
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/4636adff5682a064f0ae5f13a1d464a6_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/4636adff5682a064f0ae5f13a1d464a6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b57ce87f4c4020b22f9ec4a4f9d96c725eba6c00
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/4636adff5682a064f0ae5f13a1d464a6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8a4c7900c08332308af1eb3a5a9e0131617526c701aaebae8aef1a1dd6ae88d9
+size 39969
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6a9425ab9c3711e2cdc43bfdd99e87129dc124ef
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/523ab7b925beb555f88b2e1e1336974f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:445a0fb2c8fb07c9bad805731f11497b770cbc7c711b0b1b00f031b84f56f700
+size 81295
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2a4dbecea197d501cf8c01b5bc5c6aa41048cacb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:43ed54cae22622f933efbf044b7b4745c9aa3c4e47624c27095e74ad4148575f
+size 38262
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e4421701616080ef49d548c0298a5aea0bea53f5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/bd671b21db63e6fdb2196e9b18502aac_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e35b9ad92bcbcdfb7c60bfc0f4bcf8c09b58d7cf50af7d58fe8162a6ff926fed
+size 53441
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ef736153b5235579b3dc560335f0eb4d5e515dc2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:97765a3cbc333a135ffc4264f0681dc3831d2f32cf4e11235c2b0354942cc2ae
+size 30354
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c956f82f6a4878af4c0a05e9ef17d4e5d5afc3f1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1c74d58fb305773dc9089dcabb3500de55afb0d68a2597851dd24bd0cf6e1059
+size 47357
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/ca7c7526ec57cd5a2f278c194c0a6a00_img.jpg b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/ca7c7526ec57cd5a2f278c194c0a6a00_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b0ab0a38942877411a142eaf1e66b1434f56c87b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/ca7c7526ec57cd5a2f278c194c0a6a00_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0deb060b1bfbc61e6f9372ec0a8602c042785b2672edabd563284b29ca53cfe1
+size 39997
diff --git a/marked/Y/T-REC-Y.3323-201609-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..e959d2711ef15ff18c0bf3fd9dc1e377c13068e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3323-201609-I_PDF-E/raw.md
@@ -0,0 +1,663 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.3323
+
+(09/2016)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Future networks
+
+# --- Requirements of soft network architecture for mobile
+
+Recommendation ITU-T Y.3323
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## **FUTURE NETWORKS**
+
+**Y.3000–Y.3499**
+
+### CLOUD COMPUTING
+
+Y.3500–Y.3999
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.3323
+
+# Requirements of soft network architecture for mobile
+
+## Summary
+
+Recommendation ITU-T Y.3323 defines the design principles and requirements of soft network architecture for mobile (SAME), i.e., flexible traffic steering, virtualization of SAME network functions, SAME network slice, and separation of control function and forwarding function. Its scenarios and problem statements are introduced in the appendices.
+
+SAME is a mobile packet core network, which bridges current legacy mobile network towards future networks. Though SAME does not aim to cover key requirements of IMT-2020 core network, these key requirements of SAME may be adopted in IMT-2020.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3323 | 2016-09-29 | 13 | 11.1002/1000/13019 |
+
+## Keywords
+
+Control and forwarding separation, network function virtualization, network slice, soft network architecture for mobile, traffic steering.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2017
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|----------------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 2 |
+| 6 | Soft network architecture for mobile and its design principle..... | 2 |
+| 7 | Requirements of SAME..... | 3 |
+| | Appendix I – Scenarios of SAME..... | 5 |
+| | I.1 Flexible traffic steering..... | 5 |
+| | I.2 Virtualization of network functions..... | 6 |
+| | I.3 SAME network slice for MVNO scenario ..... | 7 |
+| | I.4 Separation of control function and forwarding function ..... | 8 |
+| | Appendix II – Problem statement of current mobile packet core network ..... | 12 |
+| | II.1 Problem in traffic steering ..... | 12 |
+| | II.2 Problem caused by proprietary hardware ..... | 12 |
+| | II.3 Problem statement of the mobile packet core gateway ..... | 12 |
+| | Appendix III – Mapping between scenarios, problems, design principles and requirements ..... | 14 |
+| | Bibliography..... | 15 |
+
+
+
+## Recommendation ITU-T Y.3323
+
+# Requirements of soft network architecture for mobile
+
+## 1 Scope
+
+Soft network architecture for mobile (SAME) is a mobile packet core network, which bridges current legacy mobile networks toward future networks. This Recommendation defines design principles of SAME, and its key requirements, i.e., flexible traffic steering, virtualization of SAME network functions, SAME network slice, and separation of control function and forwarding function.
+
+SAME scenarios and problem statements of current mobile packet core network are introduced in the appendices.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.2320] Recommendation ITU-T Y.2320 (2015), *Requirements for virtualization of control network entities in next generation network evolution*.
+- [ITU-T Y.3011] Recommendation ITU-T Y.3011 (2012), *Framework of network virtualization for future networks*.
+- [ITU-T Y.3012] Recommendation ITU-T Y.3012 (2014), *Requirements of network virtualization for future networks*.
+- [ITU-T Y.3015] Recommendation ITU-T Y.3015 (2016), *Functional architecture of network virtualization for future networks*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+None.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 traffic steering:** A technology which identifies and steers traffic to go through the related service function entities according to operators' policy.
+
+NOTE 1 – A service function entity is a traffic processing node that caches, transforms, inspects, filters, or otherwise manipulates traffic for purposes other than packet forwarding. Examples of service function entities are URL filter and video optimization.
+
+NOTE 2 – Service function entities are independent from one another, and can be added, removed and bypassed.
+
+## **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|--------------------------------------------|
+| APN | Access Point Name |
+| CAPEX | Capital Expenditure |
+| GW | Gateway |
+| HTTP | Hypertext Transfer Protocol |
+| MNO | Mobile Network Operator |
+| MVNO | Mobile Virtual Network Operator |
+| NFV | Network Function Virtualization |
+| OPEX | Operating Expenses |
+| QoE | Quality of Experience |
+| QoS | Quality of Service |
+| RAN | Radio Access Network |
+| SAME | Soft network Architecture for Mobile |
+| UE | User Equipment |
+| URL | Uniform Resource Locator |
+| VCN | Virtualization of Control Network entities |
+| VM | Virtual Machine |
+
+## **5 Conventions**
+
+In this Recommendation:
+
+The phrase "is required to" indicates a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The phrase "is recommended" indicates a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be satisfied to claim conformance.
+
+## **6 Soft network architecture for mobile and its design principle**
+
+Facing growing mobile data traffic and the rapid change of new applications, new user requirements, new service requirements and operating policies, operators need to improve the flexibility of their networks, such as using network resources more efficiently and enhancing their network capabilities more quickly.
+
+In current mobile networks, it is often difficult for operators to quickly meet market requirements, because functions are implemented on dedicated equipment and adding new features into the current network usually takes a long time to complete through test, trial and deployment. In addition, new service function entities have to be added statically, which is not flexible. Last but not least, control and forwarding functions are coupled such that they cannot be deployed flexibly and independently.
+
+To achieve the above goals, this Recommendation proposes soft network architecture for mobile (SAME), a mobile core network to be designed as an enhancement of International mobile telecommunications-advanced (IMT-Advanced) mobile packet core network, to realize an even more flexible mobile packet core network that bridges the current legacy mobile network towards future networks. Although SAME does not aim to cover key requirements of IMT-2020 core network, the key requirements of SAME may be adopted in IMT-2020.
+
+Based on the analysis of the scenarios and problems mobile operators face today, which are described in Appendices I and II, SAME focuses on implementing the following design principles:
+
+- Efficient traffic steering: Traffic can be flexibly steered to go through necessary service function entities to support quick addition of new capabilities.
+- Efficient resource usage: Infrastructure can be shared among different network functions and slices.
+- Flexible deployment of network functions: Control and forwarding functions can be deployed in a centralized or distributed manner with minimum effect to other related functions.
+- Flexible network scaling: Network functions can be dynamically adapted to users' demands.
+- Easy management of network: Resources and network functions can be managed with logically centralized, intelligent and automatic operations.
+
+NOTE – In this Recommendation, scaling includes scaling in/out, as described in [b-ETSI GS NFV 003]. The virtualization of control network entities (VCN) [ITU-T Y.2320] can be supporting technology of SAME.
+
+## **7 Requirements of SAME**
+
+This clause focuses on the key requirements for SAME.
+
+### **R1 – Support the capability of flexible traffic steering**
+
+SAME aims to support flexible enhancement of new capabilities by adding specific service function entities without affecting existing service function entities. To achieve this, SAME is expected to satisfy the requirements below.
+
+- It is required to support flexibly steering traffic passing through necessary service function entities according to the policies.
+- It is required to define and update the traffic steering policies based on the following information:
+ - application characteristics of traffic such as application type, and application protocol;
+ - access network information of traffic such as IMT-2000 access, IMT-Advanced access;
+ - users' subscription information such as users' priorities;
+ - service function entities' status such as the failure of service function entities.
+- It is required to support layer 3 through layer 7 (L3-L7) traffic classification.
+
+### **R2 – Support virtualization of SAME network functions**
+
+In SAME, virtualization refers to those network entities and/or functions run on virtual computing, storage and networking resources, leveraging the hardware and software decoupling. On virtualization, SAME is expected to satisfy the requirements below.
+
+- It is required to provide a capability for agile and flexible deployment of network functions.
+- It is required to provide a capability for scalability of network capacity by auto scaling mechanism.
+- It is required to provide a capability for efficient resource usage.
+- It is required to provide a capability for isolation of resource usage for different tenants.
+- It is required to provide a capability for operation, maintenance management and orchestration of the infrastructure in an automatic and centralized manner.
+- It is required to provide a capability to allow the virtualized resource usage to the third party.
+
+NOTE 1 – The third party assumes network customer, e.g., a mobile virtual network operator (MVNO). The third party can raise the requirement to the SAME for using network resources. A tenant or multiple tenants in the SAME are utilized to compose the third party's service.
+
+NOTE 2 – Network function virtualization (NFV) [b-ETSI GS NFV 001] [b-ETSI GS NFV 002] could be a potential technology for SAME to realize the virtualization.
+
+### **R3 – Support SAME network slice**
+
+SAME network slice is a set of SAME network functions and their related physical or virtual resources, forming a complete logical network to provide certain network characteristics. A SAME network slice is isolated from other slices based on common infrastructure. Resources can be computing, storage and networking resource. To this end, SAME is expected to satisfy the requirements below.
+
+- It is required to provide a capability to support the SAME network slices, including the creation/modification/deletion of the SAME network slices.
+- It is required to provide a capability to monitor the performance and operating status of the SAME network slices.
+- It is required to provide external application programming interfaces (APIs) to create and manage SAME network slices.
+
+NOTE – Logically isolated network partition (LINP) [ITU-T Y.3011], [ITU-T Y.3012] and [ITU-T Y.3015] can be one of realization of SAME network slice.
+
+### **R4 – Support separation of the control function and forwarding function**
+
+To achieve flexibility in deploying network equipment, control function and forwarding function should no longer be in the same equipment, whether the functions are physical or virtual. They should be able to be installed in different places. SAME aims to realize such feature through the requirements below.
+
+- It is recommended to support the capability to realize geographically centralized management of control function entities.
+
+NOTE – For example, engineers will then not need to go to different data centres or central offices to perform operational work such as deploying and powering on new servers.
+- It is required to enable scaling/deployment of control functions and forwarding functions in independent manner.
+- It is recommended to support optimization of bandwidth utilization (e.g., traffic localization, traffic scheduling) by centralized control of traffic forwarding and distributed forwarding functions.
+- It is required to support optimization of user experience (e.g., latency reduction) by deploying the forwarding functions closer to the subscriber.
+
+## Appendix I
+
+### Scenarios of SAME
+
+(This appendix does not form an integrated part of this recommendation.)
+
+The clause focuses on the scenarios for SAME.
+
+### I.1 Flexible traffic steering
+
+The identification and classification of traffic may be based on the radio access network (RAN) information (e.g., RAN type, and RAN status), application characteristics (e.g., application type, application protocol), user's subscription data, and direction (i.e., upstream or downstream) of the flow.
+
+#### Scenario 1: traffic steering classified by application type
+
+##### Descriptions
+
+SAME routes the traffic based on application type.
+
+##### Preconditions
+
+Three service function entities are deployed by the operator, which are uniform resource locator (URL) filter, protocol optimization and video optimization. Policies are defined such that the flow of a hypertext transport protocol (HTTP) video service should go to the URL filter and video optimization, and the flow of the web browsing service should go to the URL filter and protocol optimization.
+
+##### Operational flows
+
+
+
+The diagram illustrates the flexible traffic steering scenario. It shows the flow of traffic from User Equipment (UEs) through the Mobile access network and Mobile core network to a Switch/router, which then connects to the Internet. The traffic is categorized into two groups: '1. Mixed flows' and '2. Identified and separated flows'. The '2. Identified and separated flows' are further categorized into 'Web browsing' and 'HTTP video'. The 'Web browsing' flow goes through the URL filter and Protocol optimization, while the 'HTTP video' flow goes through the URL filter and Video optimization. The '3. Flows go to different service function entities' are shown as separate flows from the Switch/router to the Internet. The diagram also includes a reference to Y.3323(16)\_Fl.1.
+
+Diagram of Flexible traffic steering scenario showing traffic flow from UEs through Mobile access and core networks, then through a Switch/router to the Internet, with service function entities (URL filter, Protocol optimization, Video optimization) for traffic steering.
+
+Figure I.1 – Flexible traffic steering scenario
+
+- 1) There are two groups of flows initiated by users: HTTP video; web browsing.
+- 2) The flows of each group are identified and separated by mobile core network.
+- 3) The HTTP video flow goes through URL filter and video optimization. The web browsing flow goes through URL filter and protocol optimization.
+
+#### Scenario 2: traffic steering classified by different tenant
+
+##### Descriptions
+
+The different MVNOs may have individual requirements on the data flows processing at the (S)Gi-LAN position. The SAME network prepares appropriate service function entities and steers traffic based on the identities of the MVNOs.
+
+NOTE 1 – The service function entities could be prepared by mobile network operator (MNO), or by the MVNOs themselves for specific data flows processing.
+
+NOTE 2 – The service function entities prepared by the MVNOs could be an integrated entity of multiple sub-functions. If one of the sub-functions is the same with the MNO's data flows processing function, SAME needs to guarantee not to trigger the data flows going through the MNO's same function again.
+
+##### Preconditions
+
+There are two MVNOs in an operator's network. MVNO-A focuses more on video services and requires all of its video flows to go through a server for video optimization and transcoding. MVNO-B focuses more on web service and requires these data flows to go through the servers for HTTP acceleration.
+
+##### Operational flows
+
+- 1) The data flows are identified and labelled before routing to the packet processing area at the (S)Gi-LAN position based on the MVNO's identification information. The MVNO's identification information should have higher priority than the service information when distinguishing the data flows.
+- 2) The flows from different MVNOs are routed to different service function entities, i.e., the flow of MVNO-A goes through the video optimization and transcoding server, and the flow of MVNO-B goes through the HTTP acceleration server.
+
+### I.2 Virtualization of network functions
+
+#### Scenario 1: fast deployment
+
+##### Descriptions
+
+Utilizing NFV technology, fast deployment of the mobile network function uses the deployment template which usually contains configuration and instantiation operations and parameters to realise an automatic and dynamical deployment instead of complex manual operations.
+
+##### Preconditions
+
+The system supporting NFV is ready, and the management system can maintain and access virtual machine (VM) images and deployment templates.
+
+##### Operational flows
+
+
+
+3. Network entity module softwares installation, construct the network function
+
+```
+graph LR
+ MS[Management system] -- "1. Resource reservation and image selection" --> NFV
+ MS -- "2. VMs creating" --> NFV
+ subgraph NFV [3. Network entity module softwares installation, construct the network function]
+ VMs[VM VM VM ... VM]
+ VL[Virtualization layer]
+ subgraph Resources
+ C[Computing]
+ S[Storage]
+ N[Network]
+ end
+ end
+```
+
+Y.3323(16)\_Fl.2
+
+Diagram of fast deployment process for NFV. A Management system on the right interacts with a virtualized network function block on the left. Step 1: Resource reservation and image selection. Step 2: VMs creating. Step 3: Network entity module softwares installation, construct the network function. The block contains VMs, a Virtualization layer, and underlying Computing, Storage, and Network resources.
+
+**Figure I.2 – Fast deployment**
+
+- 1) Based on the deployment template, the management system reserves necessary resources for creating VMs and selects the desired VM images from the VM image database.
+- 2) The management system creates VMs using the selected VM images, and configures VMs e.g., IP address, the virtual hardware, and the affinity relationships based on the deployment template.
+- 3) The VMs install the software of the network entity modules, and construct the network function.
+
+#### Scenario 2: on demand resource scheduling
+
+##### Descriptions
+
+On-demand resource scheduling means dynamically adjusting resources based on traffic volume of network entity; it can be implemented by adding/deleting VMs which is named as scaling out/in, or increasing/decreasing the VM capacity which is named as scaling up/down.
+
+##### Preconditions
+
+A virtualized network entity is composed of six running VMs.
+
+##### Operational flows
+
+This operational flow shows scaling out/in.
+
+
+
+The diagram shows a 'Virtualized network entity' containing three VMMs. Each VMM has two VMs. The third VMM and its two VMs are marked with a red 'X', indicating they are to be shut down. A 'Resource management system' box on the right sends '1. Shutdown VMs' to the entity and '3. Boot VMs' back. Text inside the entity box states '2. VMs shutdown' and '4. VMs boot'. The diagram is labeled Y.3323(16)\_FI.3.
+
+Diagram illustrating the scaling out/in process. A 'Virtualized network entity' box contains three VMMs, each with two VMs. The third VMM and its two VMs are marked with a red 'X', indicating they are to be shut down. A 'Resource management system' box on the right sends '1. Shutdown VMs' to the entity and '3. Boot VMs' back. Text inside the entity box states '2. VMs shutdown' and '4. VMs boot'. The diagram is labeled Y.3323(16)\_FI.3.
+
+**Figure I.3 – Scaling out/in**
+
+- 1) The resource management system detects that the traffic volume is decreasing, and it asks the virtualized network entity to shut down the components of the entity running on two VMs.
+- 2) Two VMs in network entity is shut down, and if there is no VM running on a physical server, the physical server can be shut down.
+- 3) The resource management system detects that the traffic volume is reaching the upper threshold, it asks the virtualized network entity to boot two VMs.
+- 4) Two VMs in network entity boot, and if there is no available resource on running physical servers, a new physical server should be booted firstly.
+
+### I.3 SAME network slice for MVNO scenario
+
+##### Descriptions
+
+An MVNO utilizes part of the operator's current network, such as RAN and IP network, but wants to deploy some other functions independently, such as the gateway (GW), user profile function, IP multimedia subsystem (IMS) and application servers. The MNO provides SAME network slices to the MVNO to deploy the specific function elements in virtual manner.
+
+##### Preconditions
+
+A MVNO wants to deploy some network functions by itself except the shared infrastructure with the operator. The operator provides a SAME network slice that contains SAME functions, and related resources like computing, storage, networking, to the MVNO. The MVNO deploys its network functions on the hardware resource pool of the operator. The MNO is responsible for the management of the MVNO's network.
+
+##### Operational flows
+
+- 1) The MVNO asks the operator to provide the network resource with required network performance, such as bandwidth, session number, quality of service (QoS) level.
+- 2) The operator allocates a SAME network slice to the MVNO that contains SAME functions and related resources. The MVNO can also install individual network functions in a virtualized manner. The MVNO sets up the network and launches the services.
+- 3) The operator adjusts the SAME network slice dynamically following the requirements and the load of the network functions of the MVNO.
+- 4) The operator maintains the MVNO's network built on the hardware resource pool.
+
+
+
+The diagram illustrates the architecture of a SAME network slice for an MVNO scenario. On the left, a box labeled 'UEs' is connected by a double-headed arrow to a box labeled 'Mobile access network'. An arrow points from the 'Mobile access network' to a large dashed box representing the network slice. Inside this dashed box, there are three boxes at the top: 'Operator's functions not shared', 'MVNO-A's individual functions', and 'MVNO-X's individual functions', with an ellipsis between the last two. Below these is a box labeled 'Shared network functions'. Below the dashed box is a cloud shape containing two server icons, labeled 'Hardware resource pool, including computing/storage/networking'. The identifier 'Y.3323(16)\_FI.4' is located at the bottom right of the diagram.
+
+Diagram of SAME network slice for MVNO scenario
+
+**Figure I.4 – SAME network slice for MVNO scenario**
+
+### I.4 Separation of control function and forwarding function
+
+In these scenarios, the control function and forwarding function of mobile packet core gateway are separated. The GW control function is mainly in charge of mobility management and session management. The GW forwarding function is responsible for packet encapsulation/decapsulation for tunnelling, packet forwarding rules, forwarding performance and QoS level. The tunnel/packet routing/switch information and tunnel parameters are transferred from control function to forwarding function. The charging function could be realized on control function, forwarding function or both, which depends on the implementations. The separation of the GW's control function and forwarding function could improve the deployment flexibility, such as centralized control function and distributed forwarding function deployment, without changing the interfaces to other legacy functions.
+
+#### Scenario 1: flexible deployment of separated control function and forwarding function
+
+##### Descriptions
+
+When the GW is separated into control function and forwarding function, the control function is centralized and deployed with other mobile packet core control function such as mobility management function, and policy function.
+
+The centralization of control functions makes the operation and management easier; in addition, NFV technology can be used for the centralized control functions to achieve benefits such as resource sharing, scheduling and faster deployment.
+
+The separation of control function and forwarding function in the same equipment enables the scaling independent of each other.
+
+By separation of control function and the forwarding function, the capacity of forwarding function data handling can naturally be enhanced by increasing the number the forwarding equipment.
+
+When the control function deployed in centralized manner and the forwarding function in distributed manner, the distributed forwarding functions could realize traffic localization, because voice or video service mostly happens between users in the same region. Distributed forwarding function localizes the traffic, which will reduce the transport cost dramatically. Further, when the distributed forwarding function resides closer to the subscriber, the latency could be reduced.
+
+##### Preconditions
+
+The GW is separated into control function and forwarding function, and the control function and forwarding function can be deployed in a flexible way.
+
+##### Operational flows
+
+###### Case 1: centralized control function and forwarding function
+
+
+
+```
+graph TD;
+ GWCF[GW control function] -.-> GWFF1[GW forwarding function];
+ GWCF -.-> GWFF2[GW forwarding function];
+ GWCF -.-> GWFF3[GW forwarding function];
+ GWFF1 --- L1((Local));
+ GWFF2 --- L2((Local));
+ GWFF3 --- L1;
+ GWFF3 --- L2;
+```
+
+Diagram illustrating Case 1: centralized control function and forwarding function. A central 'GW control function' block is connected via dashed lines to three 'GW forwarding function' blocks. The three forwarding blocks are connected via solid orange lines to two 'Local' areas, each represented by a circle and a person icon. The label 'Centre' is placed near the dashed lines, and 'Local' is placed inside the circles. The diagram is labeled Y.3323(16)\_FI.5 at the bottom right.
+
+**Figure I.5 – Centralized control function and forwarding function**
+
+When the control function and the forwarding function are both deployed in a centralized manner, the control function and the forwarding functions are able to dimension and scale independently, and hence, to achieve more optimal processing and efficient resource utilization.
+
+###### Case 2: centralized control function and distributed forwarding functions: traffic localization and latency reduction
+
+
+
+The diagram shows a network architecture for traffic localization and latency reduction. At the top, a blue box labeled 'GW control function' is connected by dashed lines to three other blue boxes labeled 'GW forwarding function'. These three forwarding functions are arranged in a triangle. The central one is labeled 'Centre', while the two on the sides are labeled 'Local'. The 'Local' forwarding functions are enclosed in blue ovals, each with a corresponding 'Local' label below it. A red line represents a traffic path starting from a user equipment (UE) icon on the left, passing through the left 'Local' forwarding function, and then through the central 'Centre' forwarding function. Another red line starts from a UE icon on the right, passing through the right 'Local' forwarding function, and then through the central 'Centre' forwarding function. The text 'Y.3323(16)\_Fl.6' is located at the bottom right of the diagram.
+
+Diagram illustrating traffic localization and latency reduction in a network architecture.
+
+**Figure I.6 – Traffic localization and latency reduction**
+
+When the forwarding function is deployed closer to the subscriber, the latency could be reduced and traffic is also localized.
+
+- 1) User equipment (UE) accesses the network and sets up a video conference.
+- 2) The GW control function selects the forwarding function closest to the UE instead of the forwarding function in the centre of the network, in order to localize the traffic and reduce the network latency.
+- 3) The video conference is set up.
+
+#### Scenario 2: traffic scheduling optimization
+
+##### Descriptions
+
+The GW is separated into control function and forwarding function, the control function is centralized and the forwarding function is distributed.
+
+The control function can change the GW forwarding function (GW-U) in a flexible manner according to network policies for on-going traffic. This improves the bandwidth utilization and users' experience.
+
+##### Preconditions
+
+The GW is separated into control function and forwarding function, the control function is deployed in centralized manner and the forwarding function in distributed manner.
+
+##### Operational flows
+
+
+
+The diagram illustrates a network architecture for traffic scheduling optimization. It features two mobile access areas, Area 1 and Area 2, connected to a central Backhaul. Area 1 consists of a UE connected to a BS-BS network, which in turn connects to the Backhaul. Area 2 consists of a UE connected to a BS-BS network, which also connects to the Backhaul. The Backhaul is connected to a Distributed U-plane function, which includes four gateways: GW-U1, GW-U2, GW-U3, and GW-U4. A Centralized control function, containing Policy control and GW control function, is connected to the Distributed U-plane function. Red arrows indicate traffic flow from Area 1 through GW-U1 and GW-U2. Blue arrows indicate traffic flow from Area 2 through GW-U3 and GW-U4. The diagram is labeled Y.3323(16)\_Fl.7.
+
+Diagram illustrating traffic scheduling optimization in a mobile network. It shows two areas (Area 1 and Area 2) connected to a central Backhaul. Area 1 uses UE, BS-BS, and GW-U1/GW-U2. Area 2 uses UE, BS-BS, and GW-U3/GW-U4. A Centralized control function (Policy control, GW control function) manages the Distributed U-plane function (GW-U1, GW-U2, GW-U3, GW-U4).
+
+**Figure I.7 – Traffic scheduling optimization**
+
+- 1) UE accesses mobile access Area 1, and UE traffic goes through GW-U1 and GW-U2.
+- 2) UE moves from mobile access Area 1 to Area 2.
+- 3) GW control function can change GW-U for UE. As shown in Figure I.7, UE traffic will go through GW-U3 and GW-U4 and the traffic is optimized.
+
+## Appendix II
+
+### Problem statement of current mobile packet core network
+
+(This appendix does not form an integrated part of this Recommendation.)
+
+This clause focuses on the problem statement of the mobile packet core in the current network based on the analysis of scenarios in Appendix I.
+
+### II.1 Problem in traffic steering
+
+Faced with rapid increases of data traffic, MNOs want to and/or have to deploy many service function entities such as URL filter, video optimization, content compression to improve the user's quality of experience (QoE), to reduce the bandwidth pressure and to provide valued added services. Two kinds of service function entity models, i.e., the static serial model and the hairpin model, are deployed [b-3GPP TR 22.808].
+
+**Static serial model** is one where the service function entities are statically connected with one another, and traffic goes through all the service function entities deployed on the chain. The access point name (APN) is usually used to differentiate each service chain. However, this model has some drawbacks:
+
+- The flows go through the service function entities that are not necessarily needed. As a result, a transfer delay is added.
+- All the capabilities on the chain have to be designed to be capable of handling maximum traffic processing capacity, even though the capabilities may only be needed for part of the traffic.
+- It is difficult to adjust the service chain if a service function entity is reused in multiple service chains, e.g., a large number of configuration tasks becomes necessary when a shared service function entity is changed.
+
+**Hairpin model** is one where all service function entities are connected to a centralized traffic routing controller, and the traffic goes back to the controller to decide the next hop after the previous service function entity processing ends. However, this model has some drawbacks:
+
+- All traffic always goes through the centralized controller to determine the next hop, which significantly increases the load on the controller.
+- The centralized processing network element becomes a single point of failure.
+
+### II.2 Problem caused by proprietary hardware
+
+Network functions usually run on proprietary hardware appliances which require vendor-specific configuration tools. Frequently, the deployment of a new service requires yet another hardware box to be installed and configured. These issues add complexity to the operator's network management and service deployment, and increase operating expenses (OPEX).
+
+In addition, because proprietary hardware usually cannot be shared by different network functions, these specialized hardware appliances suffer from short lifecycles due to the fast innovation in technology and unexpected changes in customers' demands. This worsens the efficiency of capital expenditure (CAPEX) such as hardware investment.
+
+### II.3 Problem statement of the mobile packet core gateway
+
+The mobile packet core architecture has decoupled the control function and forwarding function partially by splitting the mobility management function from the hybrid control and forwarding function into mobility management function and gateway function. But the control function and
+
+forwarding function of the gateways are still tightly coupled, especially for the tunnel control and forwarding [b-IEEE-Kostas]. The current mobile gateways face some of the following issues:
+
+- The tightly coupled control function and forwarding function of mobile packet core gateway leads to the extension of hardware device as a whole, even when the control function and forwarding function have different extension requirements and capability requirement.
+- Selection mechanism of gateway is mainly based on the load information of the GW control function, not the real-time load of the forwarding function. A gateway may be selected even if its forwarding function is experiencing busy traffic overload.
+- The gateway's control function and forwarding function are located in the same equipment. However, due to the proliferation of smart phones and tablets, and people's interest in multi-media services, the mobile traffic grows exponentially. Capacity increase of forwarding function is faster than control function. If we keep to couple control function and forwarding function, it becomes difficult for the gateway to improve the data-handling capacity in a flexible manner.
+- There is a strong expectation to reduce the network latency when users search the Internet, conduct real-time communication, or others. Simply distributing the gateway closer to the RAN may lead to an increased number of gateways, and also of interfaces to other network entities like mobility management, resulting in a negative impact on configuration and network management.
+
+## Appendix III
+
+### Mapping between scenarios, problems, design principles and requirements
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Figure III.1 provides the mapping between scenarios, problems, design principles and requirements. Four high-level requirements have one-to-one mapping to four scenarios.
+
+
+
+The diagram illustrates the mapping between Problems, Principles, and Requirement/scenarios. The mapping is as follows:
+
+- Problems:**
+ - II.1 Problem in traffic steering
+ - II.2 Problem caused by proprietary hardware
+ - II.3 Problem statement of the mobile packet core gateway
+- Principles:**
+ - Efficient traffic steering
+ - Efficient resource usage
+ - Flexible deployment of network functions
+ - Flexible network capacity scaling
+ - Easy management of network
+- Requirement/scenarios:**
+ - R1 – Support flexible traffic steering
+ - R2 – Support virtualization of SAME
+ - R3 – Support SAME network slice
+ - R4 – Support separation of control and forwarding function
+
+Arrows indicate the mapping: II.1 maps to Efficient traffic steering, which maps to R1. II.2 maps to Efficient resource usage, Flexible deployment of network functions, Flexible network capacity scaling, and Easy management of network. II.3 maps to Flexible deployment of network functions, Flexible network capacity scaling, and Easy management of network. Efficient resource usage maps to R2, R3, and R4. Flexible deployment of network functions maps to R2, R3, and R4. Flexible network capacity scaling maps to R2, R3, and R4. Easy management of network maps to R2, R3, and R4.
+
+Y.3323(16)\_FIII.1
+
+Figure III.1: Mapping between scenarios, problems, design principles and requirements. The diagram shows three columns: Problems, Principles, and Requirement/scenarios. Problems include II.1 Problem in traffic steering, II.2 Problem caused by proprietary hardware, and II.3 Problem statement of the mobile packet core gateway. Principles include Efficient traffic steering, Efficient resource usage, Flexible deployment of network functions, Flexible network capacity scaling, and Easy management of network. Requirement/scenarios include R1 – Support flexible traffic steering, R2 – Support virtualization of SAME, R3 – Support SAME network slice, and R4 – Support separation of control and forwarding function. Arrows indicate the mapping between these elements.
+
+Figure III.1 – Mapping between scenarios, problems, design principles and requirements
+
+## Bibliography
+
+- [b-ETSI GS NFV 001] ETSI GS NFV 001 V1.1.1 (2013), *Network Functions Virtualisation (NFV); Use Cases*.
+- [b-ETSI GS NFV 002] ETSI GS NFV 002 V1.1.1 (2013), *Network Functions Virtualisation (NFV); Architectural Framework*.
+- [b-ETSI GS NFV 003] ETSI GS NFV 003 V1.2.1 (2014), *Network Functions Virtualisation (NFV); Terminology for Main Concepts in NFV*.
+- [b-IEEE-Kostas] Kostas P. *et al.* (2013), *Mobileflow: Toward software-defined mobile networks*, IEEE Communications Magazine, Vol. 51(7), pp. 44-53.
+< – PentikousisWH13>
+- [b-3GPP TR 22.808] 3GPP TR 22.808, *Study on Flexible Mobile Service Steering (FMSS)*.
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..61a352486dd6906c77019fcfb97278e519d267b6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/1a827b10290f33d4fec04d0e8ef7a897_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:222be1042c63974778e43a820d7418b3dc734b48e98ce706a051d0da0d1944d3
+size 30215
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/66c2bf11a8f117cddf67eff92d4c736c_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/66c2bf11a8f117cddf67eff92d4c736c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d7a2ffd386c1a2f4662a41a3584e311d841e14a0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/66c2bf11a8f117cddf67eff92d4c736c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:17ad31cdbedb884f408ec657c004915a7f91b60af48b54685440a0d799613a8b
+size 29816
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..52e9cad6a865483e22d460c1026e59c8660e200e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7ac29a8050fab184d88c2e7828bfaacc7f347c8855d9b5a87a529f59569e265c
+size 78855
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..45c8634cf01720da94314d523fce8c6e0de51903
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f830f30d9f659f1a46d5a96dff31dd8b79518055abfe202deb4cd7e2d89f1033
+size 30630
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3fbefea640ff58867256ffba8c659c933eaded72
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8c348bf9c2c81b018017ae1d19506a9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:498f033c056dd4ad04800fd97657febbcfede15e1b9e4644b79fe4251fa132fe
+size 67441
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4b9b38c5f1ef67e2481072d6b738d8dd84750e3e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b667874cc656edb6bee3c55d047144d1c74e8562058832b571ec63497479d645
+size 31750
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..df23e56601820a1f4c2f4ed809ef15b32d262089
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/90ddb84c323b956e2d50a54d3f870566_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8c818766794a24c289408a9740b6397fb7d41ebd223df0d0c8dc0be577805764
+size 87069
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/a48a54b8213bb20f6db241f20824bb51_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9b633ff9454f8010f525af120470d7f84a4faec7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bc8a7f084b2cf8dbe1b5f3b8e9d6c6929f1c84a3531852d6e48472b3227eb55f
+size 85989
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1dc36910bb4a58444137628a19182053f8097a1f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0dbff520d1629887234ba5a650ce58327a10d4a556164883add8254d9abbc350
+size 27550
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..498a13541f9b3206eb6c7a06fafb6e321614d73b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:62d5c16265f878ce2f099b9ae92a870d6cf31f83c0b13510fe628432cfbe4bf0
+size 85421
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1418243a0faae4756c6a9998a068a8017d29228b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e45fcef7b2c5d26e2bd3140d61005382aac697789e383702eb749f06346135c5
+size 80520
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e613351519a8fc4de5387e10d880725ed0ac95b6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b193b624f6d375692dd6c4f72872b19985f4246e080695bb75c9efafceb98a69
+size 121082
diff --git a/marked/Y/T-REC-Y.3325-202301-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4d9fec22d326abd4f8dc0edbbe53227ea6085b82
--- /dev/null
+++ b/marked/Y/T-REC-Y.3325-202301-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:93d7c9dfd87bb0b9a6437b7ce1f1404d1825589424e904d14603bd33e4cf1264
+size 25130
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..80a46bc083e156b02bbefb4b5aa64d5a7e6f86f2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:901f4fb86582a223b4bdfa6f13eed1b37e5b77567997e8fa4c29e3dc50492860
+size 90914
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0b821ccf10c7a3d42e26e34f2cb02468bf2c0ef6
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1be46df31c2418462c02c9c1d8207027a0b60bf876c4d4dee2d578ac5fd2bc40
+size 150662
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c7ae1d321f507b022f18f3ff3c1671fd1a2d20a7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5637e598b1c0ee39af43a0b4e21ed01af260f9202083f42cc3eaaaf8ad3fbda5
+size 94888
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fff5653b766758ae55a0061bb47d6d6fe5df4cc0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:17590138129cf887257cd5ae7ea9a0e44f4a9ad4106e53ee90ffc60b4fb180f7
+size 92106
diff --git a/marked/Y/T-REC-Y.3326-202409-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..7780d40ffa33ce0ee780761d8824d064964961d5
--- /dev/null
+++ b/marked/Y/T-REC-Y.3326-202409-I_PDF-E/raw.md
@@ -0,0 +1,466 @@
+
+
+# Recommendation
+
+## **ITU-T Y.3326 (09/2024)**
+
+SERIES Y: Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+Future networks
+
+---
+
+**Requirements and framework of distributed software-defined network intelligence capability enhancement based on distributed ledger technology**
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+### Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | Y.100-Y.999 |
+| General | Y.100-Y.199 |
+| Services, applications and middleware | Y.200-Y.299 |
+| Network aspects | Y.300-Y.399 |
+| Interfaces and protocols | Y.400-Y.499 |
+| Numbering, addressing and naming | Y.500-Y.599 |
+| Operation, administration and maintenance | Y.600-Y.699 |
+| Security | Y.700-Y.799 |
+| Performances | Y.800-Y.899 |
+| INTERNET PROTOCOL ASPECTS | Y.1000-Y.1999 |
+| General | Y.1000-Y.1099 |
+| Services and applications | Y.1100-Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200-Y.1299 |
+| Transport | Y.1300-Y.1399 |
+| Interworking | Y.1400-Y.1499 |
+| Quality of service and network performance | Y.1500-Y.1599 |
+| Signalling | Y.1600-Y.1699 |
+| Operation, administration and maintenance | Y.1700-Y.1799 |
+| Charging | Y.1800-Y.1899 |
+| IPTV over NGN | Y.1900-Y.1999 |
+| NEXT GENERATION NETWORKS | Y.2000-Y.2999 |
+| Frameworks and functional architecture models | Y.2000-Y.2099 |
+| Quality of Service and performance | Y.2100-Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200-Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250-Y.2299 |
+| Enhancements to NGN | Y.2300-Y.2399 |
+| Network management | Y.2400-Y.2499 |
+| Computing power networks | Y.2500-Y.2599 |
+| Packet-based Networks | Y.2600-Y.2699 |
+| Security | Y.2700-Y.2799 |
+| Generalized mobility | Y.2800-Y.2899 |
+| Carrier grade open environment | Y.2900-Y.2999 |
+| FUTURE NETWORKS | Y.3000-Y.3499 |
+| CLOUD COMPUTING | Y.3500-Y.3599 |
+| BIG DATA | Y.3600-Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800-Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | Y.4000-Y.4999 |
+| General | Y.4000-Y.4049 |
+| Definitions and terminologies | Y.4050-Y.4099 |
+| Requirements and use cases | Y.4100-Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250-Y.4399 |
+| Frameworks, architectures and protocols | Y.4400-Y.4549 |
+| Services, applications, computation and data processing | Y.4550-Y.4699 |
+| Management, control and performance | Y.4700-Y.4799 |
+| Identification and security | Y.4800-Y.4899 |
+| Evaluation and assessment | Y.4900-Y.4999 |
+
+For further details, please refer to the list of ITU-T Recommendations.
+
+# Recommendation ITU-T Y.3326
+
+# Requirements and framework of distributed software-defined network intelligence capability enhancement based on distributed ledger technology
+
+## Summary
+
+The distributed S-NICE enhancements is an evolved version of software-defined network intelligence capability enhancement (S-NICE) which has already been standardized by Recommendations ITU-T Y.3321 and ITU-T Y.3322. Recommendation ITU-T Y.3326 builds on those published Recommendations, and Recommendations such as ITU-T Y.2345. By introducing distributed ledger technology, the distributed S-NICE provides an efficient and reliable mechanism that prevents unauthorized parties from modifying data in the network.
+
+## History \*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T Y.3326 | 2024-09-13 | 13 | 11.1002/1000/16130 |
+
+## Keywords
+
+Distributed ledger technology, next generation network, requirements, scenarios, software-defined networking.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2024
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-----------------------------------------------------------------------------------------|------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Background..... | 3 |
+| 6.1 S-NICE ..... | 3 |
+| 6.2 Distributed ledger technology ..... | 5 |
+| 6.3 Enhancements of S-NICE for support distributed implementation based on DLT ..... | 6 |
+| 7 Requirements of S-NICE enhancements based on DLT ..... | 7 |
+| 7.1 General requirements..... | 7 |
+| 7.2 Service requirements ..... | 8 |
+| 8 Framework and capabilities of S-NICE enhancements based on DLT ..... | 8 |
+| 8.1 Overview ..... | 8 |
+| 8.2 Service layer ..... | 9 |
+| 8.3 Control layer..... | 10 |
+| 8.4 Infrastructure layer ..... | 11 |
+| 9 Security considerations..... | 11 |
+| Bibliography..... | 12 |
+
+
+
+# Recommendation ITU-T Y.3326
+
+## Requirements and framework of distributed software-defined network intelligence capability enhancement based on distributed ledger technology
+
+# 1 Scope
+
+This Recommendation illustrates the overview of the enhancement of software-defined network intelligence capability enhancement (S-NICE) for supporting distributed implementation based on distributed ledger technology, provides the scenarios and specifies the requirements and framework of distributed S-NICE enhancements for the support of distributed ledger technology in S-NICE environments.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T X.1400] Recommendation ITU-T X.1400 (2020), *Terms and definitions for distributed ledger technology*.
+- [ITU-T X.1402] Recommendation ITU-T X.1402 (2020), *Security framework for distributed ledger technology*.
+- [ITU-T Y.2322] Recommendation ITU-T Y.2322 (2018), *The functional architecture of virtualized control network entities management and orchestration next generation network evolution*.
+- [ITU-T Y.2345] Recommendation ITU-T Y.2345 (2023), *Scenarios and requirements of network resource sharing based on distributed ledger technology*.
+- [ITU-T Y.3321] Recommendation ITU-T Y.3321 (2015), *Requirements and capability framework for NICE implementation making use of software defined networking technologies*.
+- [ITU-T Y.3322] Recommendation ITU-T Y.3322 (2016), *Functional architecture for NICE implementation making use of software-defined networking technologies*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 application** [b-ITU-T Y.101]: A structured set of capabilities which provide value-added functionality, supported by one or more services.
+
+**3.1.2 block** [ITU-T X.1400]: Individual data unit of a blockchain (see clause 3.1.3), composed of a collection of transactions (see clause 6.65 of [ITU-T X.1400]) and a block header.
+
+NOTE – A block may be immutable and considered as the digital entity described in clause 3.2.2 of [ITU-T X.1255], however, it can be applied to other networks or other computational facilities.
+
+**3.1.3 blockchain** [ITU-T X.1400]: A type of distributed ledger (see clause 3.1.6) which is composed of digitally recorded data arranged as a successively growing chain of blocks with each block cryptographically linked and hardened against tampering and revision.
+
+**3.1.4 consensus** [ITU-T X.1400]: Agreement that a set of transactions is valid.
+
+**3.1.5 context** [b-ITU-T Y.2002]: The information that can be used to characterize the environment of a user.
+
+NOTE – Context information may include where the user is, what resources (devices, access points, noise level, bandwidth, etc.) are near the user, at what time the user is moving, interaction history between person and objects, etc. According to specific applications, context information can be updated.
+
+**3.1.6 distributed ledger** [ITU-T X.1400]: A type of ledger (see clause 6.36 of [ITU-T X.1400]) that is shared, replicated, and synchronized in a distributed and decentralized manner.
+
+**3.1.7 network intelligence capability enhancement (NICE)** [b-ITU-T Y.2301]: An enhanced NGN supporting some intelligent capabilities for the provisioning of services according to requirements of users and application providers. These intelligent capabilities (termed as "NICE capabilities") enable operators to assign and dynamically adjust specific network resources based on the requirements, as well as support interfaces for users and applications enabling on demand resource and service provision.
+
+**3.1.8 next generation network (NGN)** [b-ITU-T Y.2001]: A packet-based network able to provide telecommunication services and able to make use of multiple broadbands, QoS-enabled transport technologies and in which service-related functions are independent from underlying transport-related technologies. It enables unfettered access for users to networks and to competing service providers and/or services of their choice. It supports generalized mobility which will allow consistent and ubiquitous provision of services to users.
+
+**3.1.9 service** [b-ITU-T Y.2091]: A set of functions and facilities offered to a user by a provider.
+
+**3.1.10 smart contract** [ITU-T X.1400]: A program written on a distributed ledger system which encodes the rules for specific types of distributed ledger system transactions in a way that can be validated, and triggered by specific conditions.
+
+**3.1.11 software-defined networking (SDN)** [b-ITU-T Y.3300]: A set of techniques that enables to directly program, orchestrate, control and manage network resources, which facilitates the design, delivery and operation of network services in a dynamic and scalable manner.
+
+**3.1.12 user** [b-ITU-T Y.2201]: A user includes end user [b-ITU-T Y.2091], person, subscriber, system, equipment, terminal (e.g., FAX, PC), (functional) entity, process, application, provider, or corporate network.
+
+## **3.2 Terms defined in this Recommendation**
+
+None.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|---------------------------------------------|
+| BGP | Border Gateway Protocol |
+| DLT | Distributed Ledger Technology |
+| IGP | Interior Gateway Protocol |
+| NGN | Next Generation Network |
+| NICE | Network Intelligence Capability Enhancement |
+| S-NICE | Software-defined NICE |
+
+# **5 Conventions**
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+# **6 Background**
+
+## **6.1 S-NICE**
+
+Software-defined network intelligence capability enhancement (S-NICE) is a specific implementation of network intelligence capability enhancement (NICE), making use of software-defined networking (SDN) technologies [ITU-T Y.3322]. S-NICE supports the major functions of SDN technologies to make the network more scalable and flexible. Figure 6-1 provides the functional architecture of S-NICE [ITU-T Y.3322].
+
+
+
+The diagram illustrates the functional architecture of S-NICE, organized into three main functional layers, each enclosed in a red box, and connected to an external Application layer.
+
+- Application Layer:** A single block at the top labeled "Application".
+- S-NICE orchestration functions:** A red box containing:
+ - Access control FE
+ - Application development support FE
+ - Service orchestration FE
+ - Service management FE
+ - Service repository FE
+ - Network abstraction FE
+ - Network monitoring FE
+ External blocks connected to this layer include "Service user profile FE" (connected to the left) and "Content and context analysis FE" (connected to the left).
+- S-NICE controller functions:** A red box containing:
+ - Policy creation FE
+ - Topology management FE
+ - Traffic scheduling and optimization FE
+ - Policy management FE
+ - Topology collection FE
+ - Traffic monitoring FE
+ - Policy and rule translation FE
+ External blocks connected to this layer include "Management functions" (connected to the left) and "CPE functions" (connected to the left).
+- S-NICE infrastructure functions:** A red box containing:
+ - Data forwarding FE
+ - Network status reporting FE
+
+Double-headed blue arrows indicate bidirectional communication between the Application layer and the S-NICE orchestration functions, between the S-NICE orchestration functions and the S-NICE controller functions, and between the S-NICE controller functions and the S-NICE infrastructure functions.
+
+Y.3326(24)
+
+Functional architecture of S-NICE diagram showing three main layers: S-NICE orchestration functions, S-NICE controller functions, and S-NICE infrastructure functions, all connected to an Application layer.
+
+**Figure 6-1 – Functional architecture of S-NICE**
+
+S-NICE has three main functions: S-NICE orchestration functions, S-NICE controller functions and S-NICE infrastructure functions. This centralized S-NICE functional architecture could not solve the following problems:
+
+- 1) The centrally deployed orchestration and control functions may reduce the efficiency of service enabling and modifications. In S-NICE, when the user needs to establish communication with a server in the edge network, the configuration and management messages still need to be transmitted to the central orchestrator and controller to be processed
+
+there, rather than handle some service requests locally. This process will waste a lot of time and network resources, resulting in low efficiency and high delay.
+
+- 2) In fact, functions in different regions may be provided by different network providers. In order to ensure that the data will not be tampered with, each network provider should not fully trust others before distributed ledger technology (DLT) is introduced. When a fault occurs, the untrusted relationship will reduce the efficiency of service enabling and fault localization.
+
+## **6.2 Distributed ledger technology**
+
+A distributed ledger is a type of ledger that is shared, replicated and synchronized in a distributed and decentralized manner [ITU-T X.1400]. Distributed ledger technology (DLT) can record each transaction, and the records (also referred to as blocks) are chained one by one. Each record has a unique cryptographic signature, the record can be added in the distributed ledger only when the participants reach a consensus over the validity of it. DLT has technical features such as smart contracts and distributed consensus, etc.
+
+A distributed ledger has the characteristic of decentralization, which can enhance S-NICE in high fault tolerance and anti-attack scenarios. This characteristic of a distributed ledger can improve the tolerance of distributed S-NICE systems for errors and malicious attacks. For example, when an error occurs on one of the distributed S-NICE nodes, this error will not affect the other nodes in the S-NICE system, because each node has a correct copy of information. Further, if someone intends to insert erroneous information into the distributed S-NICE system, it must attack more than half of the nodes in the system simultaneously. This undoubtedly increases the difficulty and cost of launching malicious attacks.
+
+A distributed ledger also has the characteristic of reliability, which is derived from the time stamp technology of the blockchain. Once generated, data cannot be deleted or modified by unauthorized parties. The network orchestration functions and controller functions should ensure that important information such as device configuration and log records of the network will not be tampered with. This characteristic can fulfil the requirements of protection of data in a distributed S-NICE system.
+
+## **6.3 Enhancements of S-NICE for support distributed implementation based on DLT**
+
+A typical realization of a distributed S-NICE is shown in Figure 6-2. If the user needs to interact with server 1, the relevant configuration information only needs to be handled by controller 1 and orchestrator 1, and does not need to be handled by the central orchestrator. The message path is shown in a green line of Figure 6-2.
+
+
+
+Figure 6-2: A typical realization of distributed S-NICE. The diagram is divided into three horizontal layers. The top layer, 'Distributed S-NICE orchestration functions', contains a 'Central orchestrator' connected to 'Orchestrator 1', 'Orchestrator 2', and 'Orchestrator 3'. The middle layer, 'Distributed S-NICE controller functions', contains 'Controller 1', 'Controller 2', 'Controller 3', and 'Controller 4'. The bottom layer, 'Network infrastructure', contains 'Autonomous system 1', 'Autonomous system 2', 'Autonomous system 3', and 'Autonomous system 4'. A 'Client' is connected to 'Autonomous system 1'. 'Autonomous system 1' is connected to 'Cloud 1' (Server 1). 'Autonomous system 4' is connected to 'Cloud 2' (Server 2). An orange line shows a message path from 'Controller 1' to 'Controller 3' through the 'Central orchestrator'. Green lines show connections from 'Orchestrator 1' to 'Controller 1' and 'Controller 3' to 'Orchestrator 3'.
+
+Y.3326(24)
+
+**Figure 6-2 – A typical realization of distributed S-NICE**
+
+When the user needs to interact with server 2 which is in another cloud pool, beyond the management scope of controller 1, due to the fact that the data processed by DLT is resistant to modification, different function providers can trust each other and grant higher permission to the service request. The relevant configuration information can be transmitted from controller 1 to controller 3 through the distributed S-NICE controller functions. The message path is shown in orange in Figure 6-2.
+
+In addition, operators can set the corresponding contract procedures in advance by using smart contract technology. The procedures will be triggered automatically, avoiding manual operation in the whole process and ensuring the rapid enabling of services. Based on the features of DLT, the smart contract cannot be changed, which ensures reliable storage of the contract content, avoids malicious attacks or interferences with the normal contract content, and ensures that both parties can trust the contract.
+
+In distributed S-NICE, the edge network has its own orchestrator and controller, which allows most of the user demands to be handled by a local orchestrator and controller. By introducing smart contracts, the pre-configured contract program is stored in the local orchestrator and controller. When users submit their demand, the contract will be triggered automatically to enable the corresponding network services. These types of procedures can improve the efficiency of some network services compared with the traditional centralized S-NICE system.
+
+
+
+Figure 6-3: Schematic diagram of node in distributed S-NICE system being attacked. The diagram is divided into three horizontal layers. The top layer, 'Distributed S-NICE orchestration functions', contains a 'Central orchestrator' connected to 'Orchestrator 1', 'Orchestrator 2', and 'Orchestrator 3'. The middle layer, 'Distributed S-NICE controller functions', contains 'Controller 1', 'Controller 2', 'Controller 3', and 'Controller 4'. The bottom layer, 'Network infrastructure', contains 'Autonomous system 1', 'Autonomous system 2', 'Autonomous system 3', and 'Autonomous system 4'. A 'Client' is connected to 'Autonomous system 1'. 'Autonomous system 1' is connected to 'Cloud 1' (Server 1). 'Autonomous system 4' is connected to 'Cloud 2' (Server 2). A red dashed arrow with a hacker icon points to 'Controller 3', indicating an attack. Solid yellow lines show connections between the Central orchestrator and the orchestrators, and between the orchestrators and the controllers. Solid green lines show connections between the controllers and the autonomous systems.
+
+Y.3326(24)
+
+**Figure 6-3 – Schematic diagram of node in distributed S-NICE system being attacked**
+
+As shown in Figure 6-3, there is a malicious attack against controller 3, and the attack source attempts to insert some erroneous configuration information about the network services. We assume the error configuration information are inserted successfully in controller 3, and that controller 3 will advertise this information to all orchestrators and controllers in the distributed S-NICE system. The information carried by the maliciously inserted data for verification cannot pass the local authentication, so that other orchestrators and controllers will neither accept nor save this configuration information. Only when the error configuration information is inserted in more than half of the nodes (including orchestrators and controllers) in the distributed S-NICE system, it can influence the operation of the whole network.
+
+# 7 Requirements of S-NICE enhancements based on DLT
+
+## 7.1 General requirements
+
+The distributed S-NICE based on DLT is required to support service configuration data consistency. It should protect the data stored in the system from malicious tampering or modification due to some errors.
+
+The distributed S-NICE based on DLT is required to support reliable storage of configuration information, so that the historical configuration information can be obtained without any changes.
+
+The distributed S-NICE based on DLT is required to support efficiency-optimal service fulfilment, reducing the time-cost required in the process of service fulfilment thereby providing an efficient service fulfilment experience.
+
+The distributed S-NICE based on DLT is required to support efficient cross-operator collaboration, which can make different operators trust each other and improve the efficiency of fault location, operation and maintenance across networks belonging to different operators.
+
+## **7.2 Service requirements**
+
+### **7.2.1 Service configuration data consistency**
+
+The distributed S-NICE based on DLT is required to support service configuration data consistency. The data stored in the distributed S-NICE system should not be tampered with. Only in instances where the newly received configuration information passes the local authentication of more than half of the nodes in the distributed S-NICE system, can it be stored in the system.
+
+### **7.2.2 Reliable storage of configuration information**
+
+The distributed S-NICE based on DLT is required to support the reliable storage of configuration information. Data stored in the system is irreversible. Once the data passes authentication and is stored in the distributed S-NICE system, it cannot be changed or deleted. The user or operator can obtain all historical configuration information to find out the configuration information causing faults, obtain service configuration change history, etc.
+
+### **7.2.3 Efficiency-optimal service fulfilment**
+
+The distributed S-NICE based on DLT is required to support the efficiency-optimal service fulfilment. When the user needs to interact with a server/site located in the same administrative domain, the configuration information just needs to be handled by the local controller and orchestrator of the administrative domain, not the central orchestrator.
+
+The distributed ledger technology supports smart contracts, which is a piece of code that can be self-executing when the relevant service configuration instruction is triggered. This can avoid the manual operation in the process of service fulfilment, and reduce the time cost required.
+
+### **7.2.4 Efficient cross-operator collaboration**
+
+The distributed S-NICE based on DLT is required to support the efficient cross-operator collaboration. The distributed S-NICE system has the characteristics of decentralization and irreversibility, which can protect the data from malicious tampering. These characteristics enable different network operators to improve their trust in each other, and make them more willing to share network configuration data and open interfaces, which is conducive to improving the efficiency of service fault location and operation and maintenance across networks belonging to different operators.
+
+# **8 Framework and capabilities of S-NICE enhancements based on DLT**
+
+## **8.1 Overview**
+
+The distributed S-NICE framework is aligned with and enhances the S-NICE framework, as described in [ITU-T Y.3321]. The distributed S-NICE framework is shown in Figure 8-1. The capabilities illustrated within the dotted red border are those that are needed to be enhanced, while the capabilities within the solid red border are the newly added capabilities.
+
+
+
+Y.3326(24)
+
+Figure 8-1 – Framework overview of distributed S-NICE. The diagram shows a three-layer architecture: Service layer, Control layer, and Infrastructure layer. The Service layer includes a Service user profile, Service control (enhanced), Smart contract store (newly added), and Service data block handle (newly added), all within an Open environment and Distributed S-NICE orchestration. The Control layer includes Content and context analysis (enhanced), Service receiver (enhanced), Policy control, Traffic scheduling, and Service data block verification (newly added), all within a Distributed S-NICE controller. The Infrastructure layer includes Content and context detection, Policy enforcement, Traffic scheduling enforcement, and Access and core transport, all within a Distributed S-NICE infrastructure. Self-operated and Third party applications interact with the Service layer via APIs. A legend indicates that dashed red boxes represent enhanced capabilities and solid red boxes represent newly added capabilities.
+
+**Figure 8-1 – Framework overview of distributed S-NICE**
+
+The distributed S-NICE includes orchestrators (including at least one of a central orchestrator and a local orchestrator), controllers and new capabilities such as service receivers.
+
+The service layer is required to support distributed S-NICE orchestration capabilities, which is enhanced based on the S-NICE orchestration capabilities [ITU-T Y.3321]. Due to the fact that the distributed S-NICE system is the enhancement of S-NICE based on DLT, the service layer should add a smart contract storage capability and service data block handle capability to support some DLT-related enhancements. The service control capability should be enhanced to activate the smart contract program and provide the relevant service information for generating data blocks.
+
+The control layer is required to support distributed S-NICE controller capabilities, which is enhanced based on the S-NICE controller capabilities [ITU-T Y.3321]. The service data block verification capability is added to support the storage and validation of service data blocks. The content and context analysis capability should be enhanced to support service level differentiation and act as a service receiver.
+
+The infrastructure layer is required to support distributed S-NICE infrastructure capabilities [ITU-T Y.3321], which are aligned with S-NICE infrastructure capabilities and enhanced to support related distributed technologies.
+
+## 8.2 Service layer
+
+### 8.2.1 General description of service layer
+
+At the service layer, the service user profile capability and open environment capability are aligned with S-NICE [ITU-T Y.3321]. To support the enhancement based on DLT, the service control capability should be enhanced and two new capabilities, smart contract store capability and service data block handle capability, need to be added.
+
+The distributed S-NICE orchestrator which is selected by the service receiver should convert the service request message into a corresponding orchestration instruction based on the stored smart contract, and should send the instruction to the controller.
+
+NOTE – If the selected orchestrator is the central orchestrator, it should send the orchestration instructions to the corresponding local orchestrator. The local orchestrator should send the orchestration instructions to the controller; otherwise, the selected orchestrator should send the orchestration instructions to the controller.
+
+The orchestrator generates a service data block which is used to store the service configuration in the service request message, the service identifier corresponding to the service request message, and the user identifier corresponding to the user who sent the service request message. After generating the service data block, the orchestrator sends it to other orchestrators and controllers. The orchestrators and controllers should store the received service data block.
+
+Each orchestrator stores the user service data chain. The orchestrators should validate the received service data block based on the consensus mechanism of distributed ledgers. When the service data block passes validation, it is stored in the user's service data chain.
+
+### **8.2.2 Enhanced service control capability**
+
+The service control capability is required to be enhanced to activate the smart contract program and provide the relevant service information for generating data blocks.
+
+### **8.2.3 Smart contract store capability**
+
+The smart contract store capability is required to support the reliable storage of smart contracts, which can improve the distributed S-NICE system's processing efficiency during service initialization, modification and other operations.
+
+### **8.2.4 Service data block handle capability**
+
+The service data block handle capability is required to support three features: service data block generation, service data block storage and service data block validation.
+
+The service data block is used to store service-related and user-related information according to the service request message. To ensure the reliability of the information stored in the user service data chain, only the validated data blocks can be stored in the user service data chain. The service data block handle capability is required to support the reliable storage of the user service data chain. The user service data chain stored in each orchestrator or controller should be consistent.
+
+## **8.3 Control layer**
+
+### **8.3.1 General description of control layer**
+
+At the control layer, the policy control capability and traffic scheduling capability are aligned with S-NICE [ITU-T Y.3321]. The content and context analysis capability should be enhanced to support DLT-related enhancements. Service data block verification capability is a required addition.
+
+The distributed S-NICE controllers should receive the orchestration instructions, convert the orchestration instructions into service configuration information, and send the service configuration information to the network device.
+
+Each controller stores the user service data chain. The controller should validate the received service data block based on the consensus mechanism of distributed ledgers. When the user service data block passes validation, it can be stored in the user's service data chain.
+
+### **8.3.2 Enhanced content and context analysis capability**
+
+Content and context analysis capability should be enhanced to support service level differentiation and act as a service receiver, by obtaining service request messages and then determine the level of the service request message based on the service classification table. Afterwards, it determines a
+
+primary orchestrator from multiple orchestrators based on the level of the service request message, and sends the service request message to the selected orchestrator. The first orchestrator can be a central orchestrator or a local orchestrator. The service classification table is stored in the service receiver and is used to describe the type of a service request message and its service level. In addition, the payload of any data packet will not be accessed by the control layer.
+
+### **8.3.3 Service data block verification**
+
+The service data block verification capability is required to support two features: service data block store and service data block validation.
+
+When a distributed S-NICE controller receives a user service data block, the service data block verification capability should validate the user service data block based on the consensus mechanism of distributed ledgers. When the user service data block passes validation, it can be stored in the user's service data chain. Otherwise, the user service data block should be discarded.
+
+The service data block verification capability is required to support the reliable storage of user service data chain, the user service data chain stored in each orchestrator or controller should be consistent.
+
+## **8.4 Infrastructure layer**
+
+At the infrastructure layer, the capabilities of distributed S-NICE infrastructures are aligned with S-NICE infrastructure capabilities [ITU-T Y.3321]. Besides, the distributed infrastructure capabilities are required to be enhanced to support distributed technologies, including but not limited to the following features:
+
+- Support related protocols (e.g., IGP, BGP, etc.) for distributed communication between devices;
+- Support the related signalling transmission for the distributed controller to collect network data;
+- The payload of any data packet should not be accessed by the infrastructure layer.
+
+# **9 Security considerations**
+
+The security requirements of distributed S-NICE based on DLT are aligned with the security requirements of S-NICE [ITU-T Y.3321] and DLT [ITU-T X.1402], and the comprehensive study on security aspects should be deliberated within the ITU-T SG17. Furthermore, distributed S-NICE based on DLT should also consider the following aspects:
+
+- User service data block verification: When an orchestrator or controller in the distributed S-NICE system receives a user service data block, it should first verify the user service data block according to the consensus mechanism. Only verified user service data blocks can be uploaded to the user service data chain, which can prevent malicious tampering of configuration information.
+- New orchestrator/controller validation: The orchestrator or controller newly added to the distributed S-NICE system is required to be validated to prevent the generated user service data blocks from being hijacked by external devices.
+- The payload of any data packet will not be accessed.
+
+# Bibliography
+
+- [b-ITU-T Y.101] Recommendation ITU-T Y.101 (2000), *Global Information Infrastructure terminology: Terms and definitions*.
+- [b-ITU-T Y.2001] Recommendation ITU-T Y.2001 (2004), *General overview of NGN*.
+- [b-ITU-T Y.2002] Recommendation ITU-T Y.2002 (2009), *Overview of ubiquitous networking and of its support in NGN*.
+- [b-ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks*.
+- [b-ITU-T Y.2301] Recommendation ITU-T Y.2301 (2013), *Network intelligence capability enhancement – Requirements and capabilities*.
+- [b-ITU-T Y.3300] Recommendation ITU-T Y.3300 (2014), *Framework of software-defined networking*.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3327-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3327-202512-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..53078bfbc9ebd56a69cd404b5cdd3bf53193a0a9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9bf324076f42378494ef0b4d836a9d475fc95fcf756b6862be4e4f9d3c4ac0a1
+size 62080
diff --git a/marked/Y/T-REC-Y.3327-202512-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f6c7a27621d8ed38003b5f2fb7952b035d22d357
--- /dev/null
+++ b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:87ad52c5950b5040de567f5bb41f17eb2d0588182f0d1c5c26b95685afe02009
+size 112280
diff --git a/marked/Y/T-REC-Y.3327-202512-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..f2649934f1c0af3dadbd2648310fc2d497c4aadd
--- /dev/null
+++ b/marked/Y/T-REC-Y.3327-202512-I_PDF-E/raw.md
@@ -0,0 +1,583 @@
+
+
+# Recommendation
+
+## **ITU-T Y.3327 (12/2025)**
+
+SERIES Y: Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+Future networks
+
+---
+
+**Future networks including IMT-2020 –
+Framework for network complexity evaluation**
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+# Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | Y.100-Y.999 |
+| General | Y.100-Y.199 |
+| Services, applications and middleware | Y.200-Y.299 |
+| Network aspects | Y.300-Y.399 |
+| Interfaces and protocols | Y.400-Y.499 |
+| Numbering, addressing and naming | Y.500-Y.599 |
+| Operation, administration and maintenance | Y.600-Y.699 |
+| Security | Y.700-Y.799 |
+| Performances | Y.800-Y.899 |
+| INTERNET PROTOCOL ASPECTS | Y.1000-Y.1999 |
+| General | Y.1000-Y.1099 |
+| Services and applications | Y.1100-Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200-Y.1299 |
+| Transport | Y.1300-Y.1399 |
+| Interworking | Y.1400-Y.1499 |
+| Quality of service and network performance | Y.1500-Y.1599 |
+| Signalling | Y.1600-Y.1699 |
+| Operation, administration and maintenance | Y.1700-Y.1799 |
+| Charging | Y.1800-Y.1899 |
+| IPTV over NGN | Y.1900-Y.1999 |
+| NEXT GENERATION NETWORKS | Y.2000-Y.2999 |
+| Frameworks and functional architecture models | Y.2000-Y.2099 |
+| Quality of Service and performance | Y.2100-Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200-Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250-Y.2299 |
+| Enhancements to NGN | Y.2300-Y.2399 |
+| Network management | Y.2400-Y.2499 |
+| Computing power networks | Y.2500-Y.2599 |
+| Packet-based Networks | Y.2600-Y.2699 |
+| Security | Y.2700-Y.2799 |
+| Generalized mobility | Y.2800-Y.2899 |
+| Carrier grade open environment | Y.2900-Y.2999 |
+| FUTURE NETWORKS | Y.3000-Y.3499 |
+| CLOUD COMPUTING | Y.3500-Y.3599 |
+| BIG DATA | Y.3600-Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800-Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | Y.4000-Y.4999 |
+| General | Y.4000-Y.4049 |
+| Definitions and terminologies | Y.4050-Y.4099 |
+| Requirements and use cases | Y.4100-Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250-Y.4399 |
+| Frameworks, architectures and protocols | Y.4400-Y.4549 |
+| Services, applications, computation and data processing | Y.4550-Y.4699 |
+| Management, control and performance | Y.4700-Y.4799 |
+| Identification and security | Y.4800-Y.4899 |
+| Evaluation and assessment | Y.4900-Y.4999 |
+
+For further details, please refer to the list of ITU-T Recommendations.
+
+# Recommendation ITU-T Y.3327
+
+# Future networks including IMT-2020 – Framework for network complexity evaluation
+
+## Summary
+
+The network complexity is a key factor for evaluating the efficiency of the architecture and network functions for a specific network.
+
+The network complexity evaluation is implemented in the processes of verification and operation. The network complexity evaluation framework can provide design principles for improving the efficiency of architectures and network functions, and facilitate their design and optimization for future networks, including IMT-2020.
+
+Recommendation ITU-T Y.3327 addresses the general considerations, requirements, framework, procedure and security considerations of the network complexity evaluation system for future networks, including IMT-2020.
+
+## History\*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T Y.3327 | 2025-12-14 | 13 | 11.1002/1000/16620 |
+
+## Keywords
+
+Framework, IMT-2020, network complexity evaluation.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2026
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|-------------------------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere ..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | General considerations on network complexity evaluation..... | 3 |
+| | 6.1 Overview on network complexity evaluation..... | 3 |
+| | 6.2 Enabling features of network complexity evaluation..... | 4 |
+| | 6.3 Dimensions for network complexity evaluation..... | 5 |
+| 7 | Requirements of network complexity evaluation ..... | 6 |
+| | 7.1 General requirements..... | 6 |
+| | 7.2 Requirements on the NCE system and related functionalities ..... | 6 |
+| | 7.3 Requirements on performance..... | 7 |
+| 8 | Framework of network complexity evaluation..... | 8 |
+| | 8.1 Architectural framework of network complexity evaluation system ..... | 8 |
+| | 8.2 Functionalities of network complexity evaluation system ..... | 9 |
+| | 8.3 Reference points of network complexity evaluation system..... | 10 |
+| 9 | Procedure of network complexity evaluation ..... | 10 |
+| 10 | Security considerations ..... | 12 |
+| | Appendix I – Use cases of network complexity evaluation in future networks including IMT-2020..... | 13 |
+| | Bibliography..... | 14 |
+
+
+
+# Recommendation ITU-T Y.3327
+
+## Future networks including IMT-2020 – Framework for network complexity evaluation
+
+# 1 Scope
+
+This Recommendation specifies a framework for network complexity evaluation in future networks, including IMT-2020. The network complexity is a key factor for evaluating the efficiency of the architecture and network functions for a specific network. The network complexity evaluation is implemented in the processes of verification and operation. The network complexity evaluation framework can provide design principles for improving the efficiency of architectures and network functions, and facilitate their design and optimization for future networks, including IMT-2020.
+
+This Recommendation addresses the following aspects of network complexity evaluation in future networks, including IMT-2020:
+
+- General considerations;
+- Requirements;
+- Framework;
+- Procedure;
+- Security considerations.
+
+Some relevant use cases are provided in Appendix I.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [[ITU-T Y.3101](#)] Recommendation ITU-T Y.3101 (2018), *Requirements of the IMT-2020 network*.
+- [[ITU-T Y.3102](#)] Recommendation ITU-T Y.3102 (2018), *Framework of the IMT-2020 network*.
+- [[ITU-T Y.3104](#)] Recommendation ITU-T Y.3104 (2018), *Architecture of the IMT-2020 network*.
+- [[ITU-T Y.3114](#)] Recommendation ITU-T Y.3114 (2022), *Future networks including IMT-2020: requirements and functional architecture of lightweight core for dedicated networks*.
+- [[ITU-T Y.3119](#)] Recommendation ITU-T Y.3119 (2023), *Future networks including IMT-2020 – Capability classification framework for dedicated networks*.
+- [[ITU-T Y.3127](#)] Recommendation ITU-T Y.3127 (2023), *Future networks including IMT-2020 – Requirements and framework for self-organizing core network*.
+- [[ITU-T Y.3172](#)] Recommendation ITU-T Y.3172 (2019), *Architectural framework for machine learning in future networks including IMT-2020*.
+
+# 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 capability classification** [ITU-T Y.3119]: The evaluation of the capability level of a network.
+
+**3.1.2 capability level** [ITU-T Y.3119]: The level of availability of capabilities in a network.
+
+**3.1.3 control plane** [b-ITU-T Y.2011]: The set of functions that controls the operation of entities in the stratum or layer under consideration, plus the functions required to support this control.
+
+**3.1.4 data plane** [b-ITU-T Y.2011]: The set of functions used to transfer data in the stratum or layer under consideration.
+
+**3.1.5 dedicated network** [ITU-T Y.3114]: A network designed for application domains with common requirements.
+
+**3.1.6 IMT-2020** [b-ITU-T Y.3100]: Systems, system components, and related technologies that provide far more enhanced capabilities than those described in [b-ITU-R M.1645].
+
+NOTE – [b-ITU-R M.1645] defines the framework and overall objectives of the future development of IMT-2000 and systems beyond IMT-2000 for the radio access network.
+
+**3.1.7 machine learning (ML)** [ITU-T Y.3172]: Processes that enable computational systems to understand data and gain knowledge from it without necessarily being explicitly programmed.
+
+NOTE 1 – This definition is adapted from [b-ETSI GR ENI 004].
+
+NOTE 2 – Supervised machine learning and unsupervised machine learning are two examples of machine learning types.
+
+**3.1.8 machine learning overlay** [ITU-T Y.3172]: A loosely coupled deployment model of machine learning functionalities whose integration and management with network functions are standardised.
+
+NOTE – A machine learning overlay aims to minimise interdependencies between machine learning functionalities and network functions using standard interfaces, allowing for parallel evolution of functionalities of the two.
+
+**3.1.9 network function** [b-ITU-T Y.3100]: In the context of IMT-2020, a processing function in a network.
+
+**3.1.10 network intelligence level** [ITU-T Y.3173]: Level of application of automation capabilities including those enabled by the integration of artificial intelligence techniques in the network.
+
+**3.1.11 user plane** [b-ITU-T Y.2011]: A synonym for data plane.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following term:
+
+**3.2.1 network architecture entropy**: A quantitative measurement of the amount of uncertainty or randomness in the architecture of a specific network.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-----|------------------------------------------|
+| AI | Artificial Intelligence |
+| API | Application Programming Interface |
+| CNC | Coordination of Networking and Computing |
+
+| | |
+|------|-----------------------------------------|
+| DTN | Digital Twin Network |
+| FMSC | Fixed, Mobile and Satellite Convergence |
+| FQDN | Fully Qualified Domain Name |
+| HTTP | Hypertext Transfer Protocol |
+| IP | Internet Protocol |
+| MEC | Multi-access Edge Computing |
+| ML | Machine Learning |
+| NCE | Network Complexity Evaluation |
+| NFV | Network Function Virtualization |
+| PDU | Protocol Data Unit |
+| QoS | Quality of Service |
+| SDN | Software Defined Networking |
+| TCP | Transmission Control Protocol |
+| UDP | User Datagram Protocol |
+| UE | User Equipment |
+| URL | Uniform Resource Locator |
+
+## 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+# 6 General considerations on network complexity evaluation
+
+### 6.1 Overview on network complexity evaluation
+
+Network complexity is a key factor for evaluating the efficiency of the architecture and network functions of a specific network. The detailed measurement parameters may include, but are not limited to, the number of network nodes, the number of network connections, the number of network functions, the number of services, the number of interfaces, the number of protocols, the number of procedures, signalling overhead, the type of heterogeneous networks (e.g., the IMT-2020 core network [ITU-T Y.3102] and [ITU-T Y.3104], the lightweight core [ITU-T Y.3114], the self-organizing core network [ITU-T Y.3127], and the distributed core network [b-ITU-T Y.3144]), networking, computing and storage resource attributes [b-ITU-T Y.3400], and energy efficiency. The evaluation of the network complexity of a specific network may make usage of different technologies and methods, such as network architecture entropy, graph theory and complex network theory, and the digital twin network, to have quantitative measures of the complexity of a specific network.
+
+It is expected that features of new enabling technologies will be introduced in future networks including IMT-2020, which may include, but are not limited to, artificial intelligence (AI) / machine learning (ML) [ITU-T Y.3172], the distributed core network [b-ITU-T Y.3144], fixed, mobile and satellite convergence (FMSC) [b-ITU-T Y.3201], the digital twin network (DTN) [b-ITU-T Y.3090], coordination of networking and computing (CNC) [b-ITU-T Y.3400], and quantum information technologies [b-ITU-T Y.3800].
+
+The introduction of new enabling features facilitates the provision of new capabilities and new services, but may also increase network complexity. The design and optimization of architectures and network functions for future networks, including IMT-2020, should take into account the network complexity in the processes of design, verification, and operation. Therefore, it is necessary to establish a standardized framework for network complexity evaluation (NCE) for future networks including IMT-2020. The network complexity evaluation can provide design principles for improving network efficiency, reducing the redundancy of network operations, and facilitating the design and optimization of architectures and network functions for future networks including IMT-2020.
+
+### **6.2 Enabling features of network complexity evaluation**
+
+The enabling features of network complexity evaluation are the methods and technologies supporting the complexity evaluation of candidate networks. These include, but are not limited to, the following methods and technologies:
+
+#### - **AI/ML**
+
+These enabling technologies allow the network complexity evaluation (NCE) system to analyse a large amount of real-time and historical data to identify the patterns and intricate relationships of network topology, network elements, services, etc. They also help to predict the bottlenecks, vulnerabilities, redundancies, and anomalies in the network. Artificial intelligence (AI) / machine learning (ML) models can autonomously classify or cluster the network elements, giving an understanding of the complexity of the network being evaluated [ITU-T Y.3172].
+
+#### - **Network architecture entropy**
+
+Network architecture entropy is defined as a quantitative measurement of the amount of uncertainty or randomness in the architecture of a specific network. It measures the degree of disorder and unpredictability of the network being evaluated by applying information-theoretic principles to topology, traffic flows, services, etc. This approach enables the quantification of uncertainties that exist in the network. Minimizing the network architecture entropy can help to achieve higher efficiency and reliability for the network [b-Wang].
+
+#### - **Digital twin network**
+
+The digital twin network is defined as a virtual representation of a physical network. It is useful for analysing, diagnosing, emulating and controlling the physical network based on data, models and interfaces, to achieve the real-time interactive mapping between the physical network and the virtual twin network [b-ITU-T Y.3090]. It enables the NCE system to monitor and mirror the network being evaluated, and assess the impact of new configurations, network elements, services, topology changes, or potential failures before they are applied to the actual physical network.
+
+#### - **Graph theory and complex network theory**
+
+Graph theory and complex network theory provide the mathematical foundation for quantifying the complexity in IMT-2020 networks and beyond. By modelling the network as a graph (or hypergraph), the NCE system can use notions such as path length, connectivity, centrality, and modularity to assess robustness, scalability, and potential failure points of the network. Complex network theory also helps in understanding cascading effects and the impact of topology changes on the network [b-Wang].
+
+#### - **Visualization**
+
+Visualization enables the NCE system to demonstrate multidimensional data in graphical forms, allowing the users to quickly identify bottlenecks or vulnerable points of the network. Advanced visualization can demonstrate the real-time influence of changes in network topology, elements, or services, enabling intuitive interpretation or even interactive exploration of the network complexity.
+
+### 6.3 Dimensions for network complexity evaluation
+
+The dimensions for network complexity evaluation in the context of future networks, including IMT-2020, include at least one of the following ones:
+
+- Core network control plane
+
+This dimension is related to the core network control plane capabilities, including, but not limited to, mobility management capability, session management capability, connection management capability, subscription management capability, authentication and authorization capability, policy control capability, capability exposure capability, network slicing capability, and multi-access edge computing (MEC) capability.
+
+- Core network user plane
+
+This dimension is related to the core network user plane capabilities, including, but not limited to, traffic routing and forwarding capability, traffic filtering capability, protocol data unit (PDU) session tunnel management capability, quality of service (QoS) enforcement capability, service identification capability, local traffic off-load capability, local fully qualified domain name (FQDN) and uniform resource locator (URL) resolution capability, and MEC capability.
+
+- Transport network
+
+This dimension is related to the transport network capabilities, including, but not limited to, fronthaul network capability, backhaul network capability, and synchronization network capability.
+
+- Access network
+
+This dimension is related to the access network capabilities, including, but not limited to, fixed access capability, mobile access capability, and satellite access capability.
+
+- Service support
+
+This dimension is related to the service support capabilities, including, but not limited to, support of communications services, support of third-party applications, and QoS support capability.
+
+- Management
+
+This dimension is related to the management capabilities, including, but not limited to, performance management capability, fault management capability, configuration management capability, accounting management capability, security management capability, and network data analytics capability.
+
+- Virtualized network infrastructure
+
+This dimension is related to the virtualized network infrastructure capabilities, including, but not limited to, support for cloud-based architecture, support for network function virtualization (NFV) capability, support for software defined networking (SDN) capability, computing capability, storage capability, and networking capability.
+
+- AI/ML enablement
+
+This dimension is related to the AI/ML enabling capabilities, including, but not limited to, intelligent networking capability, intelligent service capability, and intelligent management capability.
+
+- DTN
+
+This dimension is related to the DTN capabilities, including, but not limited to, DTN data service capability, DTN digital twin modelling capability, DTN interactive mapping capability, DTN intelligence capability, DTN user experience capability, and DTN trustworthiness capability.
+
+# **7 Requirements of network complexity evaluation**
+
+### **7.1 General requirements**
+
+The general requirements for network complexity evaluation systems in the context of future networks including IMT-2020 are as follows:
+
+- It is required to be capable of evaluating different types of networks (e.g., the IMT-2020 network [ITU-T Y.3104], the lightweight core network [ITU-T Y.3114], the self-organizing core network [ITU-T Y.3127], and the distributed core network [b-ITU-T Y.3144]).
+- It is required to be compatible with user equipment (UE) and access networks supported by the future networks including IMT-2020.
+- It is required to minimize the impact on the operation of networks being evaluated.
+- It is required to adopt extensible architecture to meet the emerging requirements of network complexity evaluation users and adapt to the evolution of the networks being evaluated.
+
+NOTE 1 – Extensibility of the architecture of the network complexity evaluation system refers to its capability to scale out for evaluating larger networks and to scale up for evaluating more aspects and dimensions of the network.
+
+- It is required to support security and privacy mechanisms to provide sufficient data protection for diverse networks, devices, and network complexity evaluation users.
+- It is required to support the evaluation of enabling technologies introduced in future networks including IMT-2020, which may include, but are not limited to, digital twin network (DTN) [b-ITU-T Y.3090], quantum information technologies [b-ITU-T Y.3800], and AI/ML [ITU-T Y.3172].
+
+NOTE 2 – As mentioned in clause 6.1, these enabling technologies facilitate the provision of new capabilities and new services but may also increase network complexity.
+
+### **7.2 Requirements on the NCE system and related functionalities**
+
+The requirements on the NCE system and related functionalities in the context of future networks including IMT-2020 are as follows:
+
+- It is required for the network complexity evaluation system to obtain the original information on network complexity of each segment of the end-to-end network.
+NOTE 1 – The original information on network complexity includes the evaluation data and weight of evaluation elements related to network complexity, as well as the evaluation data of evaluation elements related to communications traffic.
+- It is required for the network complexity evaluation system to have the capability to acquire information from the core network, transport network, and access networks of interest, including, but not limited to, the following information:
+ - Quantity, type, detail, and message format of interfaces and protocols deployed in the network;
+ - Network topology of all network elements;
+ - Service status and dependency between services;
+ - All the related data in time series, measured in the running state of the network (e.g., by digital twin simulation).
+- It is required for the network complexity evaluation system to calculate the network complexity of each segment of the end-to-end network based on the original information on network complexity of each segment.
+- It is required for the network complexity evaluation system to determine the weight of each segment in the end-to-end network.
+
+- It is required for the network complexity evaluation system to calculate the network complexity of the end-to-end network for the purpose of optimizing the network, based on the network complexity of each segment and the weight of each segment.
+- It is required that the measuring approach of NCE is customizable, based on the requirements of the network complexity evaluation users.
+- It is required to be capable of classifying the elements of the networks being evaluated into different classes (e.g., based on dimensions as mentioned in clause 6.3; based on categories like physical, logical, and business classes as mentioned in clause 8.2, or based on other classifications that capture the similarities of the elements).
+- It is required to be capable of analysing the similarities and dependencies of the network elements and services of the network being evaluated and grouping them based on the similarities and dependencies.
+
+NOTE 2 – The dependency of network elements refers to a network element's functionality relying on the functionality or output of another network element. For instance, a network attachment control function (NACF) to establish a connection requires the functionality of a session management function (SMF).
+
+NOTE 3 – The dependency between services refers to a service relying on calling another service and using the information provided by that service as its function arguments (i.e., passed values).
+
+- It is required to adopt one or more quantitative complexity measures to evaluate the network complexity. Such measures include, but are not limited to, network architecture entropy [b-Wang], graph theory-based measures [b-Wang], and digital twin-based measures [b-ITU-T Y.3090].
+- It is required for the network complexity evaluation system to have the capability to estimate the energy efficiency of the networks of interest.
+- It is required to use external AI/ML support functionalities as an AI/ML overlay for the network complexity evaluation.
+- It is required for the network complexity evaluation system to enable the provisioning of the network complexity of each segment and the network complexity of the end-to-end network to network complexity evaluation users.
+- It is required for the network complexity evaluation system to enable the provisioning of the network optimization requirements from network complexity evaluation users.
+
+NOTE 4 – The network complexity evaluation users produce the network optimization requirements based on the network complexity of each segment and the network complexity of the end-to-end network.
+
+- It is required for the network complexity evaluation system to produce the optimization instruction for each segment of the end-to-end network.
+- It is required for the network complexity evaluation system to facilitate the optimization of each segment of the end-to-end network with the optimization instructions for each segment.
+- It is required for the network complexity evaluation system to have user-friendly interfaces for evaluation results, such as application programming interfaces (APIs) and graphical interfaces.
+
+### **7.3 Requirements on performance**
+
+#### **7.3.1 Requirements on the performance of the network complexity evaluation system**
+
+The requirements on the performance of the network complexity evaluation system in the context of future networks including IMT-2020 are as follows:
+
+- It is required for the network complexity evaluation system to be capable of evaluating a network that supports the services and applications supported by the IMT-2020 network, as specified in [ITU-T Y.3101].
+- It is required for the network complexity evaluation system to provide a comprehensive network complexity evaluation result, considering access networks, transport networks, and core networks.
+- It is required for the network complexity evaluation system to be capable of evaluating the influence of the dynamic changes in the network being evaluated on the network complexity.
+- It is required for the network complexity evaluation system to be robust to minor changes in the network being evaluated.
+- It is required for the network complexity evaluation system to be scalable in terms of the increase or decrease of dimensions of the network being evaluated.
+- It is required for the network complexity evaluation system to have the ability to provide the network complexity evaluation result in qualitative and/or quantitative form, up to the network complexity evaluation user's requirements.
+- It is required for the network complexity evaluation system to support security and privacy protection aspects, as well as to align with the relevant requirements specified in [ITU-T Y.3101].
+
+#### **7.3.2 Requirements on the performance of the network being evaluated**
+
+The requirements on the network being evaluated in the context of future networks including IMT-2020 are as follows:
+
+- It is required for the network being evaluated to support the services and applications required by the IMT-2020 network, as specified in [ITU-T Y.3101].
+- It is required for the network being evaluated to support customized services and applications.
+- It is required for the network being evaluated to support the service requirements specified in [ITU-T Y.3101].
+- It is required for the network being evaluated to support the network capability requirements specified in [ITU-T Y.3102] and [ITU-T Y.3104].
+- It is required for the network being evaluated to be compatible with UEs and access networks supported by the IMT-2020 network.
+- It is required for the network being evaluated to support interaction with the AI/ML overlay.
+
+## **8 Framework of network complexity evaluation**
+
+### **8.1 Architectural framework of network complexity evaluation system**
+
+Figure 8-1 depicts the high-level framework of network complexity evaluation system, in the context of future networks, including IMT-2020.
+
+
+
+The diagram illustrates the high-level framework of a network complexity evaluation system. At the top, a purple box labeled 'Network complexity evaluation users' is connected to a central box labeled 'Network complexity evaluation system' via a line labeled 'RP-ex5'. The central box is divided into two main sections. The top section, labeled 'Overall measurement', is connected to three 'Detailed measurement' boxes below it. The bottom section, labeled 'Future networks including IMT-2020', contains three boxes: 'Access network', 'Transport network', and 'Core network'. The 'Overall measurement' section is connected to the 'Detailed measurement' boxes via lines labeled 'RP-ex1', 'RP-ex2', and 'RP-ex3'. The 'AI/ML overlay' box, shown in green, is connected to the 'Detailed measurement' boxes via a line labeled 'RP-ex4'. The 'Future networks including IMT-2020' section is connected to the 'Detailed measurement' boxes via lines labeled 'RP-ex1', 'RP-ex2', and 'RP-ex3'. The diagram is labeled 'Y.3327(25)' at the bottom right.
+
+High-level framework of network complexity evaluation system diagram
+
+**Figure 8-1 – High-level framework of network complexity evaluation system**
+
+In the high-level framework, the network complexity evaluation system collects network complexity-related information from core network, transport network, and access network of a specific network; it performs the detailed measurement and overall measurement of the network complexity of this network; it provides the results of network complexity evaluation to network complexity evaluation users, and to this network as feedback. The AI/ML overlay is an external system which provides AI/ML capabilities to the network complexity evaluation system; it may adopt the framework of the high-level architecture specified in [ITU-T Y.3172].
+
+The detailed measurement consists of different instances of the detailed measurement functionality. The overall measurement consists of the elements classification functionality, elements grouping functionality, and network complexity evaluating functionality.
+
+### 8.2 Functionalities of network complexity evaluation system
+
+- Detailed measurement functionality: This functionality is used to gather information of the network from the dimensions mentioned in clause 6.3.
+- Elements classification functionality: This functionality is used to classify the elements of the network being evaluated into different classes, e.g., the physical, the logical, and the business class.
+
+NOTE 1 – The physical class includes the physical devices in the network being evaluated; the logical class includes the logical or virtual network functions in the network being evaluated; the business class includes the applications and services required or called by the users of the network being evaluated.
+
+It also supports intra-class elements grouping functionality for each class.
+
+- Elements grouping functionality: This functionality is used to group the elements of each class, based on their dependency, similarity and geographic or logical relationships. Each class has an independent intra-class elements grouping functionality, and there is one inter-class elements grouping functionality dealing with the inter-class groups.
+
+NOTE 2 – An inter-class group is a group of network elements that consists of network elements from more than one class. For instance, an inter-class group could have network elements from both physical and logical classes.
+
+- Network complexity evaluating functionality: This functionality is used to compute the network complexity. For instance, a quantitative measure of the network complexity is the network architecture entropy [b-Wang].
+
+### 8.3 Reference points of network complexity evaluation system
+
+The reference points of the network complexity evaluation system for future networks including IMT-2020 are as follows:
+
+- RP-ex1: The reference point between the detailed measurement function and access network functions. The configuration of this reference point follows the requirements and specific protocols for that interface related to the corresponding access network.
+- RP-ex2: The reference point between the detailed measurement function and transport network functions. The configuration of this reference point follows the requirements and specific protocols for that interface related to the corresponding transport network.
+- RP-ex3: The reference point between the detailed measurement function and core network functions. The configuration of this reference point follows the requirements and specific protocols for that interface related to the corresponding core network.
+- RP-ex4: The reference point between the detailed measurement function and AI/ML overlay. The configuration of this reference point follows the requirements and specific protocols for that interface related to AI/ML functionalities specified in [ITU-T Y.3172].
+- RP-ex5: The reference point between the overall measurement function and network complexity evaluation users.
+
+NOTE – The system provides the network complexity evaluation results to the users. These reference points use user-friendly interfaces and protocols, such as APIs or graphical interfaces.
+
+The above reference points are expected to adopt a protocol stack based on the hypertext transfer protocol (HTTP) / transmission control protocol (TCP) / Internet protocol (IP) for control-related interfaces and a protocol stack based on HTTP / user datagram protocol (UDP) / IP for user-related interfaces and data transmission-related interfaces.
+
+## 9 Procedure of network complexity evaluation
+
+The procedure of network complexity evaluation for IMT-2020 networks and beyond allows for a detailed measurement of the network being evaluated, the classification of the network being evaluated, the network elements grouping, and the quantitative evaluation of the network complexity.
+
+Figure 9-1 depicts the procedure of network complexity evaluation, in the context of future networks, including IMT-2020. The network being evaluated has been qualified according to the dimensions mentioned in clause 6.3.
+
+
+
+```
+
+sequenceDiagram
+ participant DMF as Detailed measurement functionality
+ participant ECF as Elements classification functionality
+ participant ICGF as Intra-class elements grouping functionalities
+ participant ICIF as Inter-class elements grouping functionality
+ participant NCEF as Network complexity evaluating functionality
+ participant NCU as NCE user
+
+ DMF->>DMF: 1. Data collection
+ DMF->>ECF: 2. Identification of network elements and send data to elements classification functionality
+ ECF->>ECF: 3. Elements classification
+ ECF->>ICGF: 4. Create elements grouping functionalities and provide them classification results
+ ICGF-->>ICIF: 6. Share the grouping results with inter-class elements grouping functionality and network complexity evaluating functionality
+ ICGF-->>NCEF: 6. Share the grouping results with inter-class elements grouping functionality and network complexity evaluating functionality
+ ICGF-->>ICIF: 7. Clustering of inter-class groups
+ ICGF-->>NCEF: 8. Send inter-class grouping results to network complexity evaluating functionality
+ NCEF-->>NCEF: 9. Computation of complexity
+ NCEF-->>NCEF: 10. Computation and source-tracing of the network complexity, NCE report generation
+ NCEF->>NCU: 11. Send NCE report
+
+```
+
+Y.3327(25)
+
+Sequence diagram illustrating the procedure of network complexity evaluation. The diagram shows the flow of data and control between various functional blocks: Detailed measurement functionality, Elements classification functionality, Intra-class elements grouping functionalities (First class, Second class, etc.), Inter-class elements grouping functionality, Network complexity evaluating functionality, and NCE user. The process follows 11 steps: 1. Data collection, 2. Identification of network elements and send data to elements classification functionality, 3. Elements classification, 4. Create elements grouping functionalities and provide them classification results, 5a. Clustering of groups in the first infra-class, 5b. Clustering of groups in the second infra-class, 5c. ..., 6. Share the grouping results with inter-class elements grouping functionality and network complexity evaluating functionality, 7. Clustering of inter-class groups, 8. Send inter-class grouping results to network complexity evaluating functionality, 9. Computation of complexity, 10. Computation and source-tracing of the network complexity, NCE report generation, and 11. Send NCE report.
+
+**Figure 9-1 – Procedure of network complexity evaluation**
+
+The steps shown in Figure 9-1 are as follows:
+
+1. The detailed measurement functionality collects the relevant data of the network being evaluated, and thus identifies the relevant network elements in the network being evaluated.
+2. The detailed measurement functionality sends the collected data and identified network elements to the elements classification functionality.
+3. The elements classification functionality performs classification based on criteria specified by the user (e.g., based on dimensions or categories mentioned in clauses 7.2 and 8.2).
+4. The elements classification functionality creates one infra-class element grouping functionality for each of the classes, together with an inter-class element grouping functionality, and provides them the classification results of step 3.
+5. For each infra-class element grouping functionality, based on the dependency, similarity and geographic or logical relationships, the identified network elements of the corresponding class are clustered into infra-class groups.
+6. The infra-class element grouping functionality shares the infra-class grouping results with the inter-class element grouping functionality and the network complexity evaluating functionality.
+7. The inter-class element grouping functionality clusters the identified network elements into inter-class groups based on the dependency, similarity and geographic or logical relationships.
+
+8. The inter-class element grouping functionality sends the inter-class grouping results to the network complexity evaluating functionality.
+9. Together with the historical data of the network being evaluated and the received infra-class and inter-class grouping results, the network complexity evaluating functionality computes the infra-class complexity of each class for the network design state and running state. The network complexity evaluating functionality also computes the inter-class complexity.
+NOTE – The design state of the network refers to the network before running it. The running state refers to the network operating state.
+10. Based on the computing results of step 9, the network complexity evaluating functionality computes the overall network complexity and traces the sources of the network complexity (e.g., the infra-class groups that have a high network architectural complexity), and generates a comprehensive NCE report based on the NCE user's requirements.
+11. The network complexity evaluating functionality sends the NCE report to the NCE user.
+
+## **10 Security considerations**
+
+The security and privacy considerations of network complexity evaluation in the context of future networks including IMT-2020 include the following aspects:
+
+- Security of the networks being evaluated, which includes the security considerations on the core network, transport network, and access network of the network being evaluated.
+- Security of the network complexity evaluation system, which includes the security considerations on the detailed measurement, elements classification, elements grouping, network complexity evaluating, and AI/ML support functions. The secure operations of the functionalities and the information exchange between the functionalities are to be addressed.
+- User privacy, which includes the privacy considerations on the detailed measurement, elements classification, elements grouping, and network complexity evaluating functions which are storing, caching, and processing privacy-sensitive user data and network data. The transmission of privacy-sensitive data is subject to authentication, authorization, and privacy management.
+
+In addition, the security and privacy requirements of the network complexity evaluation system are aligned with the requirements specified in [ITU-T Y.3101].
+
+# Appendix I
+
+## Use cases of network complexity evaluation in future networks including IMT-2020
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The followings are use cases of network complexity evaluation in future networks including IMT-2020.
+
+Use case 1: To choose a core network architecture for a dedicated network
+
+An operator plans to deploy a dedicated network in a specific environment (with certain computing capability, storage capability, and networking capability). Three core network architectures are available for the operator, including the IMT-2020 core network [ITU-T Y.3102] and [ITU-T Y.3104], the lightweight core [ITU-T Y.3114], and the self-organizing core network [ITU-T Y.3127]. The operator plans to choose a core network architecture with the minimum network complexity for the specific environment. The network complexity evaluation can help in this use case.
+
+Use case 2: To facilitate the design and optimization of architectures and network functions for IMT-2030 network
+
+"Framework and overall objectives of the future development of IMT for 2030 and beyond" [b-ITU-R M.2160-0] specifies the usage scenarios of IMT-2030, which include "immersive communication", "hyper reliable and low-latency communication", "massive communication", "ubiquitous connectivity", "artificial intelligence and communication", "integrated sensing and communication". The introduction of new usage scenarios may increase the network complexity. The design and optimization of architectures and network functions for IMT-2030 network should take into account the network complexity in the processes of verification and operation. The network complexity evaluation can help in this use case.
+
+# Bibliography
+
+- [[b-ITU-T Y.2011](#)] Recommendation ITU-T Y.2011 (2004), *General principles and general reference model for Next Generation Networks*.
+- [[b-ITU-T Y.3090](#)] Recommendation ITU-T Y.3090 (2022), *Digital twin network – Requirements and architecture*.
+- [[b-ITU-T Y.3100](#)] Recommendation ITU-T Y.3100 (2017), *Terms and definitions for IMT-2020 network*.
+- [[b-ITU-T Y.3144](#)] Recommendation ITU-T Y.3144 (2024), *Future networks including IMT-2020 – Requirements and functional architecture of distributed core network*.
+- [[b-ITU-T Y.3173](#)] Recommendation ITU-T Y.3173 (2020), *Framework for evaluating intelligence levels of future networks including IMT-2020*.
+- [[b-ITU-T Y.3201](#)] Recommendation ITU-T Y.3201 (2023), *Fixed, mobile and satellite convergence – Framework for IMT-2020 networks and beyond*.
+- [[b-ITU-T Y.3400](#)] Recommendation ITU-T Y.3400 (2023), *Coordination of networking and computing in IMT-2020 networks and beyond – Requirements*.
+- [[b-ITU-T Y.3800](#)] Recommendation ITU-T Y.3800 (2019), *Overview on networks supporting quantum key distribution*.
+- [b-ITU-R M.1645] Recommendation ITU-R M.1645 (2003), *Framework and overall objectives of the future development of IMT-2000 and systems beyond IMT-2000*.
+- [b-ITU-R M.2160-0] Recommendation ITU-R M.2160-0 (2023), *Framework and overall objectives of the future development of IMT for 2030 and beyond*.
+- [b-ETSI GR ENI 004] Group Report ETSI GR ENI 004 V3.1.1 (2023), *Experiential networked intelligence (ENI); Terminology*.
+- [b-Wang] Wang, X., Liu, C., He, J. et al. (2023), 6G Network Architecture Based on Digital Twin: Modeling, Evaluation, and Optimization, *IEEE Network*,
+<>
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|----------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b7ef43f26fc68def73d693525c645b0b63adaceb
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/043e64d41a3368d138ace3816fd26469_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c66d18fe6ec7d4982bf52547890f663008f9f18d42bfaf59fd0dde649faa3ab6
+size 110398
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..68b45ac334f0595e8390698930240be81fee7a6e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/053f1077d592e6622cd21dc4bb4cb366_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bf6cb1ef2ca149b52ffb5717d1722200cf685b99fa0f4389d7d56d10243d0244
+size 26882
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f791897ad633bc3e3ab0ffd1e9f7b804d15d5844
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/10781f43062bf3e9601a1e086710556c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ca1c684a92e7dd4f4b2537e7f9221e9b2cefa3225c093293ee02695f8ab156b6
+size 32724
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/5414f65867392f05ba0063b208eeb5e1_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/5414f65867392f05ba0063b208eeb5e1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4a6391df70e6c72b4ef2b68779b3fe728eedb29d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/5414f65867392f05ba0063b208eeb5e1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:07a5ca195f3b91a80823008b4bd3a8ba171751aaca24f51598baae14ada14f88
+size 32507
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/705ee99c3c44fd2a1ea6a3348ce8878f_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/705ee99c3c44fd2a1ea6a3348ce8878f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d17ce17539696a093794c3a012defc706a49bb60
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/705ee99c3c44fd2a1ea6a3348ce8878f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1e8c219138d36fee809b7ac4482fc940a03f58cb97d8fe627e38ab56f6d6ee72
+size 35658
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..83de44cfa91ff96cd6d044185230bbdca1aff85e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:92c3c68bcdb95caa413d3d9a4747655489556a99ef57b3def4ad289d99ef7337
+size 6615
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ceddb60aeb9c1d56ca3cd05033a0a12490253b98
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:937261ebdffdbacd0e1a326477ba0565bf7a84120fea4298df84e215cbf61dc7
+size 104584
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/ad6c36347e94fca1b0d1be8b0035401e_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/ad6c36347e94fca1b0d1be8b0035401e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f696f4b1cfa53dce99b13a6194327ef65c1aba1b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/ad6c36347e94fca1b0d1be8b0035401e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3285fb525345c8919032ca9c29f3b42e387f71da31e8674dd72a99b96c304923
+size 38461
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..43833e077e91d9fa6377d3c736c7aab049f3f1e2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:20887c7774351b741a0754390cbba35edbe687ded5a678c55a7059f4d143026e
+size 24642
diff --git a/marked/Y/T-REC-Y.3503-201405-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..b293397de7a6ca169bb55c8834a60887054cf314
--- /dev/null
+++ b/marked/Y/T-REC-Y.3503-201405-I_PDF-E/raw.md
@@ -0,0 +1,798 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+# Y.3503
+
+(05/2014)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS
+AND NEXT-GENERATION NETWORKS
+
+Cloud Computing
+
+# --- Requirements for desktop as a service
+
+Recommendation ITU-T Y.3503
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with two red lightning bolts striking it. To the right of the globe, the text "ITU" is written in a large, bold, blue font, and below it, the words "International Telecommunication Union" are written in a smaller, blue font.
+
+ITU logo: a blue globe with red lightning bolts and the text 'ITU International Telecommunication Union'
+
+# ITU-T Y-SERIES RECOMMENDATIONS **GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS AND NEXT- GENERATION NETWORKS**
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.3503
+
+# Requirements for desktop as a service
+
+## Summary
+
+As one of cloud computing service categories, desktop as a service (DaaS) provides cloud service customers with desktop functions remotely delivered by cloud service providers. Recommendation ITU-T Y.3503 introduces the concept of DaaS, and describes general and functional requirements. To derive those requirements relevant use cases are also presented.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3503 | 2014-05-22 | 13 | 11.1002/1000/12167 |
+
+## Keywords
+
+Desktop as a service, DaaS, virtual desktop, virtual desktop infrastructure.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2014
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|------------------------------------------------------------------------------------------------------------------|-------------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere ..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 1 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Convention..... | 3 |
+| 6 | Introduction to desktop as a service (DaaS) ..... | 3 |
+| | 6.1 Main advantages of DaaS ..... | 5 |
+| | 6.2 General configuration for DaaS..... | 5 |
+| | 6.3 Interaction between DaaS components ..... | 7 |
+| 7 | DaaS general requirements ..... | 7 |
+| 8 | DaaS functional requirements ..... | 8 |
+| | 8.1 Operation and management requirements ..... | 8 |
+| | 8.2 DaaS platform-side functional requirements..... | 9 |
+| | 8.3 DaaS client-side functional requirements..... | 10 |
+| | 8.4 DaaS platform-DaaS client interaction functional requirements..... | 11 |
+| | 8.5 DaaS security requirements ..... | 11 |
+| 9 | Security considerations ..... | 12 |
+| | Appendix I – Relationship between DaaS logical components and the cloud computing reference architecture..... | 13 |
+| | Appendix II – DaaS client classification..... | 14 |
+| | Appendix III – DaaS use cases ..... | 15 |
+| | Appendix IV – Value for response time limit..... | 22 |
+| | Appendix V – Service provisioning based on CSC types in DaaS..... | 23 |
+| | V.1 Types of cloud service customer ..... | 23 |
+| | V.2 User account provisioning based on CSC types in DaaS ..... | 23 |
+| | V.3 Service provisioning in DaaS ..... | 24 |
+| | Bibliography..... | 25 |
+
+
+
+# Recommendation ITU-T Y.3503
+
+# Requirements for desktop as a service
+
+# 1 Scope
+
+This Recommendation provides use cases, general requirements and functional requirements for desktop as a service (DaaS).
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T X.1601] Recommendation ITU-T X.1601 (2014), *Security framework for cloud computing*.
+- [ITU-T Y.3501] Recommendation ITU-T Y.3501 (2013), *Cloud computing framework and high-level requirements*.
+- [ITU-T Y.3510] Recommendation ITU-T Y.3510 (2013), *Cloud computing infrastructure requirements*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+- 3.1.1 cloud service customer** [ITU-T Y.3501]: A person or organization that consumes delivered cloud services within a contract with a cloud service provider.
+- 3.1.2 cloud service provider** [ITU-T Y.3501]: An organization that provides and maintains delivered cloud services.
+- 3.1.3 hypervisor** [ITU-T Y.3510]: A type of system software that allows multiple operating systems to share a single hardware host.
+- 3.1.4 virtual machine** [b-DMTF OVF]: The complete environment that supports the execution of guest software.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+- 3.2.1 DaaS client**: A physical device and associated software running on the device that collectively enables a cloud service user to access desktop as a service (DaaS).
+- 3.2.2 desktop as a service (DaaS)**: A cloud service category in which the capabilities provided to the cloud service customer are the ability to build, configure, manage, store, execute and deliver users' desktop functions remotely.
+- 3.2.3 virtual desktop**: An environment for accessing end user's desktop functions remotely.
+
+NOTE – Examples of end user's desktop functions can include desktop interface functions for applications, data access functions for multimedia data, and control functions for input/output (I/O) devices.
+
+**3.2.4 virtual desktop infrastructure (VDI):** A desktop as a service (DaaS) solution enabling the hosting of a desktop operating system within a virtual machine.
+
+NOTE – In this Recommendation, VDI means that the virtual machine hosting the desktop operation system is running in a cloud computing environment.
+
+**3.2.5 virtual desktop template:** A representation of a set of system configuration and application parameters with an option of including customer personalization, and other desired attributes.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|-------------------------------------|
+| 3D | Three Dimensional |
+| 3G | Third Generation |
+| CPU | Central Processing Unit |
+| CSC | Cloud Service Customer |
+| CSP | Cloud Service Provider |
+| CRM | Customer Relationship Management |
+| DaaS | Desktop as a Service |
+| DCN | Data Communication Network |
+| DHCP | Dynamic Host Configuration Protocol |
+| DNS | Domain Name System |
+| DTLS | Datagram Transport Layer Security |
+| ERP | Enterprise Resource Planning |
+| FEC | Forward Error Correction |
+| GPS | Global Positioning System |
+| HD | High Definition |
+| HTML | Hypertext Markup Language |
+| HTTP | Hypertext Transfer Protocol |
+| IaaS | Infrastructure as a Service |
+| I/O | Input/Output |
+| IT | Information Technology |
+| LAN | Local Area Network |
+| OS | Operating System |
+| PLMN | Public Land Mobile Network |
+| PSTN | Public Switched Telephone Network |
+| QoE | Quality of Experience |
+| RAM | Random Access Memory |
+| SLA | Service Level Agreement |
+
+| | |
+|-----|--------------------------------|
+| SSL | Secure Socket Layer |
+| TCP | Transmission Control Protocol |
+| UDP | User Datagram Protocol |
+| VDI | Virtual Desktop Infrastructure |
+| VM | Virtual Machine |
+| VPN | Virtual Private Network |
+
+# 5 Convention
+
+The keywords "**is required to**" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The keywords "**is recommended**" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement need not be present to claim conformance.
+
+The keywords "**can optionally**" indicate an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+In the body of this Recommendation and its annexes, the words shall, shall not, should, and may sometimes appear, in which case they are to be interpreted, respectively, as is required to, is prohibited from, is recommended, and can optionally. The appearance of such phrases or keywords in an appendix or in material explicitly marked as informative are to be interpreted as having no normative intent.
+
+# 6 Introduction to desktop as a service (DaaS)
+
+DaaS is defined as a cloud service category in which the capabilities provided to the cloud service customer (CSC) are the ability to build, configure, manage, store, execute and deliver users' desktop functions remotely. With DaaS, the user experience is achieved through a user interface, which is presented on a DaaS client over the network. Figure 6-1 shows the conceptual view of DaaS.
+
+
+
+Figure 6-1: Conceptual view of DaaS. This diagram illustrates the architecture of Desktop as a Service (DaaS). On the left, an 'Enterprise' is shown with multiple 'Cloud service customer' icons (people at computers). In the center, a large blue cloud represents the 'Cloud infrastructure', containing 'Virtual desktops' (represented as a grid of desktop icons) and 'Cloud service provider' servers. On the right, 'Home' and 'Mobile' environments are shown, each with 'Cloud service customer' icons. Arrows indicate the flow of data and services between the enterprise, the cloud infrastructure, and the home/mobile environments. A red dashed box highlights the connection between the virtual desktops and the cloud service provider servers.
+
+**Figure 6-1 – Conceptual view of DaaS**
+
+Y.3503(14)\_F6-1
+
+Instead of maintaining and running a desktop operating system and applications on CSC devices, servers of a cloud service provider (CSP) located in the cloud are used to execute the instances of users' virtual desktops. This allows a party (e.g., an organization) to run end user's operating systems and applications, and keep their data in the cloud computing environment.
+
+Based on application streaming and virtualization technologies, CSCs can access the virtual desktop environment through cloud infrastructure.
+
+A few technologies can be used for providing services of the DaaS like virtual desktop infrastructure (VDI) and web-based solutions with various delivery protocols such as the virtual desktop delivery protocol and the web-based delivery protocol shown in Figure 6-2.
+
+
+
+Figure 6-2: DaaS delivery solutions. This diagram shows the layers of a DaaS delivery solution. At the top is the 'User layer' containing two 'DaaS client' boxes. Below this is the 'Access layer', which is connected to the User layer via 'Virtual desktop delivery protocol' and 'Web-based delivery protocol' arrows. The Access layer is connected to the 'Services layer', which is connected to the 'Resource layer'. The Services layer and Resource layer are represented as stacked blocks. A blue cloud icon with three dots is positioned between the Access layer and the Services layer.
+
+Y.3503(14)\_F6-2
+
+**Figure 6-2 – DaaS delivery solutions**
+
+VDI supports the users' virtual desktop and recreates it in an environment hosted on a remote system. A virtual desktop is executed for each user from the server side. Users access this
+
+environment remotely through DaaS clients, with all virtual desktop associated processing. A virtual desktop delivery protocol is used to deliver the virtual desktop.
+
+In the web-based DaaS solution, a web-based server invokes application services from different servers and aggregates them to build a virtual desktop service. The web-based DaaS solution relies on cloud services provided through the use of web oriented technologies, i.e., based on the hypertext transfer protocol (HTTP), hypertext markup language (HTML) and the new features supported by HTML5 [b-W3C-HTML5].
+
+## 6.1 Main advantages of DaaS
+
+The main advantages of DaaS [b-ITU-T FGCC1] are:
+
+- **Enhanced management and security:** Since all desktop applications actually run in a CSP server, they are more secure than if they were installed on each user's DaaS client since the CSP can focus more on security aspects.
+- **Lower total cost of ownership:** By placing emphasis on the data centre rather than on individual user devices, DaaS promotes longer hardware life. Organizations or enterprises seeking to avoid additional costs can switch part of their information and communication technology infrastructure from capital expenditure to operating expenditure, as they now pay for virtual desktops. Also, decoupling the desktop operating system from the hardware permits the use of cost-effective user's devices.
+- **Preservation of user experience:** DaaS allows for a rich user experience by enabling the possible choice among multiple operating systems and their customization. Conversely, shared service environments offer a user experience that may compromise between application compatibility and user customization.
+- **Separation of CSP and CSC responsibilities:** DaaS allows separation between the responsibilities of the CSP and the CSC. The CSP is responsible for the infrastructure of virtual desktops delivery (i.e., servers, storage, virtualization software, etc.), while the virtual desktops (e.g., operating system (OS), application packaging, user profiles, etc.) is under the CSC responsibility.
+
+## 6.2 General configuration for DaaS
+
+Figure 6-3 shows the general configuration environment for DaaS logical components. The environment is based on a traditional client-server model and mainly consists of a DaaS client, a connection manager, a resource pool, a virtualization infrastructure and a virtual desktop delivery. Detailed interaction among these DaaS logical components are described in clause 6.3.
+
+NOTE 1 – Relationship between DaaS logical components and the cloud computing reference architecture in [b-ITU-T FGCC2] is described in Appendix I. Further study of the DaaS architecture is needed to map the DaaS logical components to the cloud computing reference architecture.
+
+
+
+```
+graph LR
+ subgraph DaaS_platform [DaaS platform]
+ VDD[Virtual desktop delivery]
+ VI[Virtualization infrastructure]
+ CM[Connection manager]
+ RP[Resource pool]
+ VDD --- VI
+ CM --- VI
+ CM --- RP
+ VI --- RP
+ end
+ DC[DaaS client] --- CM
+```
+
+Y.3503(14)\_F6-3
+
+Figure 6-3: General configuration for DaaS. The diagram shows a DaaS client connected to a DaaS platform. The DaaS platform contains four components: Virtual desktop delivery, Virtualization infrastructure, Connection manager, and Resource pool. The DaaS client is connected to the Connection manager. The Connection manager is connected to both the Virtual desktop delivery and the Resource pool. The Virtualization infrastructure is connected to the Resource pool.
+
+**Figure 6-3 – General configuration for DaaS**
+
+The main logical DaaS components, shown in Figure 6-3, are as follows:
+
+### - DaaS client
+
+DaaS users can be provided with their virtual desktop remotely through their DaaS clients. To access a DaaS platform, DaaS users can employ one of the methods among dedicated software, general-purpose web browser and firmware depending on the type of DaaS client. More detailed information regarding DaaS clients is provided in Appendix II.
+
+NOTE 2 – Depending on the type of DaaS client, when the DaaS client is booted up, it starts a log in procedure to a corresponding virtual desktop with access information such as its identification, password and IP address. In case of termination of the corresponding virtual desktop, the DaaS client recognizes it and begins a log out procedure which includes turning off the virtual machine (VM) or the DaaS client.
+
+### - Connection manager
+
+This logical component is responsible for connecting a DaaS user to an available and suitable virtual desktop. The connection manager's tasks include:
+
+- user authentication and licence verification to validate the user and the user's application;
+- assignment of a virtual desktop;
+- coordination of a delivery protocol to be used between a DaaS client and a DaaS platform; and
+- allocation of necessary storage.
+
+In addition, the connection manager is responsible for load balancing and managing the number of users per DaaS platform, reconnecting a user to the virtual desktop.
+
+The connection manager uses the resource pool and the virtualization infrastructure to allocate the required resources such as computing, network and storage in virtualization infrastructure.
+
+### - Resource pool
+
+Resource pool is an abstraction of software resources such as OS, applications and user profiles. The software resources can be loaded from the resource pool to given resources in the virtualization infrastructure. A resource pool can offer provisioning information regarding the software resources on request by a connection manager.
+
+NOTE 3 – A user profile can contain individual information about hardware configuration (i.e., central processing unit (CPU), random access memory (RAM), I/O), used OS, selected applications and user computing environment information (e.g., display resolution and Internet access means).
+
+### - Virtualization infrastructure
+
+The main role of the virtualization infrastructure is to support hardware and software resources and create virtual resources (e.g., VMs). The virtualization infrastructure can use a virtualization function, called a hypervisor, to manage hardware resource efficiently. A hypervisor can abstract physical hardware resources and assign them dynamically to a virtual desktop. In this case, the end user's application runs on the virtual desktops provided by the virtualization infrastructure. The virtualization infrastructure supports high availability features (e.g., multiple VMs are created from the same VM template) with pre-defined configuration parameters.
+
+### - Virtual desktop delivery
+
+This component is responsible for encapsulation and delivery of either access to an entire information system environment, or the environment itself to a remote DaaS client through the network. A protocol for virtual desktop delivery provides the communication channels between the DaaS client and the DaaS platform in order to transfer all the interaction information. The interaction information includes display information, control and configuration information, monitoring information, etc.
+
+DaaS can be serviced by either a personalized virtual desktop or by a virtual desktop from a shared pool. In the case of a personal virtual desktop, there is a one-to-one mapping between a virtual desktop and a cloud service user. Each user is assigned a virtual desktop that can be personalized and customized. These changes are available to the user each time that user logs on to his or her personal virtual desktop. For a shared virtual desktop pool, a single OS image is replicated across many VMs and users can reuse a single VM over time. As users connect to the shared virtual pool, they are dynamically assigned a virtual desktop. A shared virtual pool allows for uniformed experience across all end users, while combined with simplified administration means.
+
+## 6.3 Interaction between DaaS components
+
+To illustrate the DaaS operation concepts based on Figure 6-3, the various steps of an example interaction for DaaS are shown as follows:
+
+- A DaaS client accesses a connection manager through a security protocol (such as secure shell or transport layer security) and the connection manager validates the user with a user-ID and associated password.
+- The connection manager identifies a corresponding user profile and, in order to assign appropriate virtual resources in the virtualization infrastructure, a provisioning operation helps the connection manager to allocate the virtual resources that satisfies the user's hardware configuration and is optimal to the computing environment.
+- If there are no proper virtual resources, the connection manager requests the virtualization infrastructure to create such virtual resources according to the hardware configuration requested by the user or a pre-defined hardware configuration.
+- After such virtual resources are assigned or created, the connection manager applies the user profile, including installation of OS and applications, to construct a virtual desktop.
+- A connection to deliver a corresponding virtual desktop is created in the virtualization infrastructure and the information of the connection is dispatched to the connection manager.
+- The connection manager sends the connection information to the DaaS client and the DaaS client connects to the virtual desktop in the virtualization infrastructure.
+- The DaaS client communicates with the virtual desktop through the network using a delivery protocol for the virtual desktop.
+- When a DaaS user terminates a virtual desktop service, the DaaS client executes a log out operation without loss of user data.
+- During the log out operation, the connection manager updates the modified user profile in a user profile pool to keep the most recent information, and releases the VM resources.
+
+# 7 DaaS general requirements
+
+The DaaS general requirements are described in [ITU-T Y.3501] as follows:
+
+- Quality of experience (QoE);
+- Fast boot-up time;
+- Configurability of the virtual environment;
+- Single sign-on access control.
+
+Additional general requirements of DaaS derived from use cases (cf. Appendix III) include (but are not limited to):
+
+- **Support for high-definition (HD) and three-dimensional (3D) applications:** DaaS can optionally support execution of HD applications on virtual desktops for CSCs.
+
+NOTE 1 – HD and/or 3D applications (e.g., high-definition 3D videos or games) are becoming one of the major user demands in the personal computing device market.
+
+- **Extensible storage:** It is recommended that a CSP support the storage extension requested by a CSC.
+- **Response time:** It is recommended that DaaS provide CSCs with acceptable QoE.
+
+NOTE 2 – Detailed relevant information on acceptable response time is described in Appendix IV.
+
+- **High availability:** It is recommended that high availability in terms of delivery and operation of DaaS be assured by a CSP.
+- **Resiliency to disaster:** In a case of a disaster, DaaS is recommended to provide and maintain an acceptable level of service.
+
+NOTE 3 – This includes preserving the system information and the users' data including their virtual desktop state such as power-on, power-off, suspend, etc.
+
+- **Service continuity:** It is recommended that in case of temporarily unavailable resource access, a CSP provides the capability to preserve the state of the user session.
+- **System scalability:** It is recommended that DaaS supports elastic scalability of:
+ - Storage for DaaS user account information, virtual desktop environment settings, and active and inactive virtual desktop environments;
+ - Processing and network capacity for the number of concurrent DaaS user connections and total DaaS users;
+ - Underlying DaaS resources.
+- **DaaS developer environments:** It is recommended to provide a developer environment for the service and contents regarding DaaS.
+- **Diversity of DaaS client:** It is recommended that the CSP support a wide selection of DaaS clients.
+
+NOTE 4 – Examples of such DaaS clients are described in Appendix II.
+
+# 8 DaaS functional requirements
+
+## 8.1 Operation and management requirements
+
+Operation and management requirements include:
+
+- **Unified management interface:** It is recommended that the CSC be capable of deploying, configuring, managing and monitoring the DaaS through a unified management interface.
+- **User account provisioning:** It is recommended that the CSP provide the method of operating and provisioning various types of accounts in accordance with CSC's characteristics based on the service level such as one-time usage and permanent account, types of virtual desktop environments, and allocating options for the virtual desktop environments.
+
+NOTE 1 – User account provisioning depending on the CSC types is described in Appendix V.
+
+- **Virtual desktop lifecycle management:** It is required that the CSP support the full life cycle management of the virtual desktop, including set-up, test, delivery, use, maintenance, optimization, shutdown and deletion.
+- **Support of virtual desktop template:** In order to achieve better delivery of DaaS, a desktop template can be optionally used for DaaS maintenance purposes.
+
+NOTE 2 – The virtual desktop template includes defining, publishing, verifying, revoking, deleting and other related operations.
+
+- **User profile management:** It is required that the CSP manage the user profile information.
+
+- **Server-side platform hardware resource maintenance:** It is required that the CSP maintain and allocate servers, storage, network and related hardware.
+- **Service-related resource maintenance:** It is required that the CSP maintain DaaS service supporting applications and data, such as security auditing server, performance monitoring server, active directory, database, user configuration, file server, etc.
+- **Status monitoring:** It is recommended that the current running status of virtualized resource be monitored to perform the change the status requested by a CSC.
+- **System load monitoring:** In order to achieve an appropriate QoE, it is recommended that a CSP be capable of monitoring the system load to assign virtualized resources to a CSC.
+- **Automated scriptable management interface:** It is recommended that the DaaS management solution be accessible through a consistent scripting interface.
+- **Power management:** It can optionally be that the CSP is able to support the mechanism that monitors server's power and relevant usage in order to perform load balancing or save the power consumption in the server.
+- **Accounting and charging:** It is recommended that the CSP collect accounting information based on computing power, network use, storage, memory and/or application licence fee. Accounting information is collected per service and per user. It is also recommended that the CSP provide a charging scheme based on the accounting information and charging information transparently.
+
+NOTE 3 – Depending on the implementation of DaaS, the charging scheme may not be needed.
+
+- **Managing and operating pre-configured environments:**
+ - It is recommended that the CSP manage and operate the pre-configured environments which are prepared after configuring the service information (such as server processing capacity, the prediction of concurrent users and the resources capacity, etc.).
+ - It is recommended that the CSP provide the preconfigured environment without the loss of user functionality and the degradation of performance when service is requested.
+
+NOTE 4 – The pre-configured environments are the environmental files such as images of OS and applications, which reflect the CSC's requirements including operating environment, installed applications, user data and level of service. The pre-configured environments are prepared in advance with the related operations (e.g., generating, creating, reproducing and cloning, etc.) and supplied in their use during service execution.
+
+- **Monitoring and controlling DaaS:** It is recommended to monitor and control the activities of a DaaS platform without impacting the performance of the DaaS platform.
+
+NOTE 5 – A software agent can be used to communicate with a kernel or a hypervisor in order to create and control VMs.
+
+- **DaaS client capability:** It is recommended that virtualization infrastructure supports making use of any available DaaS client capability on the CSC's device as and when required by application programs running in virtual desktop.
+- **User log management:** It is recommended that the CSP keep the connection log information for all CSCs and their event logs for further security and/or incident analysis.
+
+## 8.2 DaaS platform-side functional requirements
+
+The DaaS platform-side functional requirements include:
+
+- **Maintaining DaaS user status:** It is required that the CSC be capable of reconnecting to virtual desktop in the same virtual desktop state as left.
+
+- **Optimized adaptation for content type:** It is recommended that the DaaS client be optimized for the content type involved (e.g., each type of content is encoded with a codec that is tuned to best support the content and the codec configuration can be automatically changed based on the content type such as multimedia, images and text).
+- **Isolation between virtual desktop functions:** It is required that the operation of the virtual desktop functions of one CSC should not be negatively impacted by the use of virtual desktop functions by other CSCs.
+- **Graphic processing acceleration support:** In order to provide ability to DaaS clients to work with graphic-intensive software packages (such as 3D computer-aided design or compression) running on the server, it is recommended that the CSP provide the acceleration of graphic processing to DaaS clients.
+- **Server-side rendering:** In order to provide a consistent user experience to a wide range of DaaS clients as well as to improve user experience, it is recommended that the local desktop be composed and rendered on the host before the resulting image is encoded and sent to the DaaS client.
+- **Standard video codec support:** For applicable video content, it is recommended to support standard codecs, such as specified in [b-ITU-T H.264] or [b-ITU-T H.265].
+- **Progressive encoding support:** For networks with limited bandwidth, in order to improve user experience in case of a network bottleneck, it is recommended to use progressive encoding.
+
+NOTE – Progressive encoding and rendering means that the image can be encoded and sent over several stages, and the image quality becomes progressively clearer at each stage.
+
+- **CSC environment backup:**
+ - It is recommended that the CSP backup and restore the allocated virtual machines with user environment in order not to lose user data.
+ - It is recommended that the CSP should not degrade the service performance from the process of backing up and restoring.
+- **Standard audio encoder support:** It is recommended to support standard audio encoders.
+
+## 8.3 DaaS client-side functional requirements
+
+The DaaS client-side functional requirements include:
+
+- **Resource request:** It is recommended that the CSC be capable of configuring the system resources in its use (e.g., CPU, memory, storage and other devices) during service execution.
+- **Support of DaaS client peripherals:** It is recommended that DaaS applications be able to use DaaS client peripherals.
+
+NOTE 1 – Examples of DaaS client peripherals include USB port, flash memory, global positioning system (GPS), camera, etc.
+
+- **Video decoder support:** For rendering video content on client, it is recommended to support standard codecs, such as specified in [b-ITU-T H.264] or [b-ITU-T H.265] to decode encoded images.
+- **Standard audio decoder support:** It is recommended to support standard audio decoders.
+- **Synchronization between DaaS client and DaaS platform:** It is recommended that DaaS support synchronization of DaaS user state when the connection is established and terminated.
+
+NOTE 2 – DaaS user state include desktop background and layout, user interface preferences, current DaaS user timezone, etc.
+
+## 8.4 DaaS platform-DaaS client interaction functional requirements
+
+The functional requirements related to the interaction between DaaS platform and DaaS client include:
+
+- **Dynamic configuration adaptation:** To improve network throughput, it is recommended that a DaaS client be able to dynamically determine its access network types and adapt its configuration (including the network protocols and display resolution) accordingly to ensure network connectivity and improve the user experience.
+- **Standard transport protocol support:** It is required to use standard transport protocols (e.g., transmission control protocol (TCP) [b-IETF RFC 793] and user datagram protocol (UDP) [b-IETF RFC 768]) to deliver DaaS.
+- **High latency environment:**
+ - For applications and elements that are less sensitive to packet loss and only dependent on low latency and jitter (such as for desktop rendering, audio, video streaming, or communications), a loss-tolerant transport (e.g., UDP) can optionally be used for allowing immediate delivery with some packet loss, without any need to wait for retransmission of lost packets.
+ - For those applications and elements where data reliability is important (e.g., for typing), it is recommended to use the standard transports available for this purpose that allows recovering from losses without retransmissions, such as forward error correction (FEC).
+
+NOTE 1 – DaaS is very sensitive to latency and jitter (variation in latency). For example, when DaaS users type text or move a mouse they need to see this appear almost immediately on their screens. For this reason, retransmission is often unacceptable as a mean of error recovery. This constraint on latency and jitter imposes the following DaaS-specific requirements when suffering from latency.
+
+- **Fall-back to alternative transport:** When the standard transport protocol is not available, it is recommended that an automatic fall-back to the alternative protocol is implemented by the DaaS application. An example would be a fall-back from UDP to TCP.
+- **DaaS client reconnection:** When there is no response from the DaaS platform to a service request from a DaaS client, it is required that the DaaS client send a reconnection request to the DaaS platform. If the reconnection fails, it is also required that a DaaS user be notified of loss of service.
+- **Display redirection:** It is required that the CSP redirect display to a CSC immediately after the completion of the connection between a DaaS platform and a DaaS client.
+- **Hybrid resource configuration:** It is recommended that resources in both a DaaS platform and a DaaS client be used simultaneously to achieve the best performance and the CSP support the ability to modify their configuration to improve the performance.
+
+NOTE 2 – Hybrid means that there can be various combinations of resource configuration between a DaaS client and a DaaS platform.
+
+## 8.5 DaaS security requirements
+
+- **Standard security protocols support:** It is recommended to use standard security protocols for content delivery protection for DaaS (e.g., secure socket layer (SSL) [b-IETF RFC 6101] and datagram transport layer security (DTLS) [b-IETF RFC 6347]).
+- **Network separation:** It is recommended that DaaS provide policy-based separation between the DaaS client's local network, DaaS provided network and the public Internet network. This separation can be logical (e.g., virtual private network (VPN)) or physical as appropriate.
+
+NOTE – In addition to cloud-based resources, DaaS users may require access to local network resources (such as printers), or the public Internet.
+
+# **9 Security considerations**
+
+It is recommended that the security requirements of [b-ITU-T Y.2201], [b-ITU-T Y.2701] and applicable X, Y and M series of ITU-T security Recommendations be taken into consideration, including access control, authentication, data confidentiality, communications security, data integrity, availability and privacy. It is also recommended that the security framework for cloud computing described in [ITU-T X.1601] be considered. [ITU-T X.1601] analyses security threats and challenges in the cloud computing environment, and describes security capabilities that could mitigate these threats and meet security challenges.
+
+# Appendix I
+
+## Relationship between DaaS logical components and the cloud computing reference architecture
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix provides the relationship between DaaS logical components, which are described in clause 6.2, and the cloud computing reference architecture [b-ITU-T FGCC2].
+
+
+
+The diagram illustrates the mapping of DaaS logical components to the layers of the cloud computing reference architecture. It consists of four stacked layers, each with a specific DaaS component:
+
+- User layer** (light blue): Contains the **DaaS client** component.
+- Access layer** (orange): Contains the **Connection manager** component.
+- Services layer** (light blue): Contains the **Virtual desktop delivery** component.
+- Resource and network layer** (teal): Contains two components: **Resource pool** and **Virtualization infrastructure**.
+
+Y.3503(14)\_F1.1
+
+Diagram showing the mapping of DaaS logical components to cloud computing reference architecture layers.
+
+**Figure I.1 – An example of location of DaaS logical components within the layers of the cloud computing reference architecture**
+
+Figure I.1 shows an example of the location of the DaaS logical components, which are related to layers in the cloud computing reference architecture.
+
+Since the user layer provides the user interface between CSC and CSP, the DaaS client logical component can be related to this layer in that a DaaS CSC accesses the virtual desktop through this component.
+
+The capability to provide the connection between DaaS CSCs and virtual desktops is the main role of the connection manager. This DaaS logical component corresponds to the access layer of the cloud computing reference architecture.
+
+The virtual desktop delivery DaaS logical component facilitates the implementation of the virtual desktop by employing a delivery protocol. Therefore, this DaaS logical component is related to the services layer of the cloud computing reference architecture.
+
+The resource pool and the virtualization infrastructure as DaaS logical components provide an abstraction of software and hardware resources. These two DaaS logical components are related with the resource and network layer of the cloud computing reference architecture.
+
+# Appendix II
+
+## DaaS client classification
+
+(This appendix does not form an integral part of this Recommendation.)
+
+DaaS users access their virtual desktops using networked DaaS clients, such as desktop computers, thin clients and mobile devices. Basically, most of these devices rely on computing power in DaaS platforms for all or a majority of their applications. Several ways to access virtual desktops from DaaS clients can be provided. Some DaaS clients support specific software dedicated to DaaS while some do not require specific software on the DaaS client and instead use a general web browser to interact with the DaaS platform. Still, some DaaS clients can directly connect without any software or browsers. Table II.1 shows the characteristics of various types of DaaS clients, including these access methods
+
+**Table II.1 – Characteristics of DaaS client**
+
+| Categories | Personal computer | Thin client | Mobile device |
+|---------------|-----------------------------------|-----------------------------------|-----------------------------------|
+| Access method | Dedicated software web browser | Dedicated software Web browser | Dedicated software web browser |
+| Network | Mainly wired | Mainly wired | Wireless |
+| CPU | Performance-centric | Power-centric | Power-centric |
+| RAM | Yes | Yes | Yes |
+| Storage | Yes (Hard disk drive) | Yes/No (Flash memory) | Yes (Flash memory) |
+
+# Appendix III
+
+## DaaS use cases
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes seven DaaS-related use cases in Tables III.1 to III.7.
+
+**Table III.1 – Office automation of development-oriented enterprise**
+
+| Legend | Use case |
+|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Office automation of development-oriented enterprise |
+| Use case description | In this scenario, the DaaS users access the enterprise applications and data hosted in virtual desktops which are created within a DaaS platform. Common applications of this type include online word processing, email, communication, co-operating development, etc. The sales staff also can view customer information and marketing records on the enterprise website. The DaaS platform interacts with traditional enterprise information and communication technology facilities to achieve many control tasks, for instance, using dynamic host configuration protocol (DHCP) to assign an IP address for thin client, leveraging internal domain name system (DNS) server to resolve local host names, and consulting authentication of user desktop sessions. |
+| High-level figure describing the use case | Image: Diagram illustrating the DaaS architecture for office automation. A thin client (represented by two people at a monitor) connects to a VDI infrastructure cloud. Inside the cloud, three Desktop VMs are shown, each containing Profiles, Apps, and OS layers. An Enterprise IT application is shown on the left, and Enterprise IT applications (Office, CRM, VSS/TFS) are shown on the right. The VDI infrastructure connects to Enterprise IT infrastructure, which includes AD (Active directory), DHCP, DNS, Firewall, and other services. A reference to Y.3503(14)_FIII.1 is included.
The diagram illustrates the DaaS architecture for office automation. A thin client (represented by two people at a monitor) connects to a VDI infrastructure cloud. Inside the cloud, three Desktop VMs are shown, each containing Profiles, Apps, and OS layers. An Enterprise IT application is shown on the left, and Enterprise IT applications (Office, CRM, VSS/TFS) are shown on the right. The VDI infrastructure connects to Enterprise IT infrastructure, which includes AD (Active directory), DHCP, DNS, Firewall, and other services. A reference to Y.3503(14)_FIII.1 is included.
|
+| Derived requirements | – Single sign-on access control – QoE – Standard video codec support – Support of DaaS client peripherals – Standard security protocol support |
+
+**Table III.2 – Customer service call centre**
+
+| Legend | Use case |
+|-------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Customer service call centre |
+| Use case description | Virtual desktop pool supports distributed deployment model and can be deployed in the cloud computing infrastructure as a service (IaaS) resource pool with the dynamic stretching of resources.
By adopting cloud computing technology (virtualization, distributed computing and storage, cluster, etc.) to consolidate queuing resource and desktop resources, unified phone call dispatching and delivery and maintenance of the desktop can be achieved in an intensive way.
|
+| High-level figure describing the use case | Image: Diagram of a Customer Service Call Centre architecture showing service representatives, cloud desktop pool, CTI pool, unified queuing, and unified accessing components.
The diagram illustrates the architecture of a customer service call centre. At the top, four teams of service representatives (Team 1 to Team 4) are shown, each with a 'TC' (Team Console) and a 'Service representatives' label. Below them is a 'Clouddesk pool' containing several server icons. A 'DCN/LAN' cloud is connected to the Clouddesk pool. The Clouddesk pool is connected to a 'Business platform' which includes 'CRM/ERP/billing' components. To the right, a 'CTI pool' contains 'CTI 1', 'CTI 2', and 'CTI N' components. A 'Unified queuing' cloud is connected to the CTI pool. Below the CTI pool, a 'Unified accessing' cloud is connected to an 'IP core' cloud, a 'PSTN/PLMN' cloud, and an 'Internet' cloud. The diagram is labeled 'Y.3503(14)_F.11.2' at the bottom right.
|
+| Derived requirements | – Unified management interface – Automated scriptable management interface – Diversity of DaaS client |
+
+**Table III.3 – Scenario of DaaS user**
+
+| Legend | Use case |
+|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Scenario of DaaS user |
+| Use case description | Scenario of DaaS user is driven by a specific class of user. Common user types that benefit from DaaS are mobile workers, task workers (such as factory floor and call centre workers), contractor/offshore workers, and remote workers in branch offices.
• Mobile workers: If an organization needs to support employees who are mobile, work from home or work from the road, a DaaS solution can enable employee productivity anywhere and increase effective user collaboration without compromising security. DaaS can offer secure access to desktops and applications over low-bandwidth connections without requiring new applications to be distributed to DaaS users. Employees will see a consistent set of applications and can access their own data regardless of location. If employees need access to a comprehensive desktop experience, they can be assigned a personal virtual desktop within the confines of the corporate data centre. This improves the DaaS offering available to users while keeping the environment securely managed. With the wide adoption of third-generation (3G) wireless networks, users are even more capable of experiencing a full-fidelity desktop remotely. |
+
+**Table III.3 – Scenario of DaaS user**
+
+| Legend | Use case |
+|-------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | • Task workers: If an organization includes structured task workers, such as in call centres and retail branches, DaaS can provide a more cost-effective and productive user experience because these user roles do not typically need access to multiple applications to complete business processes. Additionally, there are situations when the location is simply not capable of supporting a fully functioning client computer; instead, thin-client solutions are more applicable. The same experience can be provided even if the client computer is a legacy computer. This type of deployment can extend the reach of applications within the enterprise and is a valuable way to deliver the right business tools in a cost-effective way. • Contractor/Offshore workers: Many companies are leveraging workforce experience from around the world. Organizations will need to provide access to applications for users located both remotely and internationally. In order to provide access to resources while respecting corporate policies, providing a virtual desktop or virtual desktop pool becomes very attractive for organizations. This allows users to receive a first-class client on the network while allowing the organization to control where the virtual desktop is running, how the virtual desktop is accessed, how data is being run on the client computer and where data is stored. • Remote workers in branch offices: In an environment that relies on remote or branch offices, DaaS can provide enhanced capabilities to these sites and reduce the network bandwidth that the required applications use. For example, a bank might have essential financial software applications that would not be cost-effective to deploy and maintain in every branch. With DaaS, the software can be available at a central headquarters and accessed as needed by employees in different locations. A centralized-applications strategy often results in a reduction of application server infrastructure at various branches or locations, requiring much less maintenance and on-site support from the home office information technology (IT) staff. |
+| High-level figure describing the use case | |
+| Derived requirements | – Single sign-on access control – Service continuity – Diversity of DaaS client – Managing and operating pre-configured environment – Maintaining DaaS user status – CSC environment backup – Standard transport protocols support |
+
+**Table III.4 – Local resource usage**
+
+| Legend | Use case |
+|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Local resource usage |
+| Use case description | In this scenario, an application hosted in a DaaS platform requires input from the local resources where a DaaS client is located, i.e., user terminal, to function properly. For instance, an image-based search application will require input from a camera on the terminal; the location based application may require GPS information from the GPS module running on the terminal; the schedule planner would require calendar data (meetings, task) from the terminal. For instance, Alice is using an application called "My locality" which provides a list of near-by attractions. This application makes use of GPS information, from the GPS module running in its host, to find the exact current user location. Since the application is being used remotely and hosted on the network, it needs the user terminal to provide its GPS information for the application to provide correct results (attractions near the user not near the server where the application is hosted). When Alice uses the application, local GPS data are sent to the server where they are used to provide correct results.
|
+| High-level figure describing the use case | Image: Diagram illustrating local resource usage in a DaaS environment. Cloud service customers (laptops) send data to a central cloud (VD infrastructure). Data types include GPS information (dotted blue arrows), image from camera (solid red arrows), and calendar data (dashed green arrows). Specific examples: '02/04/2013, e-meeting, 2:00 - 4:00 p.m.', '02/02/2013, presentation, 1:00 - 2:00 p.m.', '02/07/2013 - 02/31/2013 winter vacation', '02/10/2013 my birthday'. Applications shown: Image based search application (Application A) and Schedule planner (Application B). Cloud service provider (servers) is also indicated.
The diagram shows a central cloud labeled 'VD infrastructure' connected to 'Cloud service customers' (represented by laptops) and a 'Cloud service provider' (represented by server racks). Data flows from customers to the cloud and then to the provider. Three types of data are shown: GPS information (dotted blue arrows), image from camera (solid red arrows), and calendar data (dashed green arrows). Specific data points include: '02/04/2013, e-meeting, 2:00 - 4:00 p.m.', '02/02/2013, presentation, 1:00 - 2:00 p.m.', '02/07/2013 - 02/31/2013 winter vacation', and '02/10/2013 my birthday'. Applications shown are 'Image based search application (Application A)' and 'Schedule planner (Application B)'. A legend at the bottom indicates the arrow types for GPS information, image from camera, and calendar data. A reference code 'Y.3503(14)_FIII.4' is at the bottom right.
|
+| Derived requirements | – Support of DaaS client peripherals |
+
+**Table III.5 – Service continuation for DaaS**
+
+| Legend | Use case |
+|----------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Service continuation for DaaS |
+| Use case description | In this scenario, a consumer is using a particular DaaS. Due to network unavailability, the consumer gets disconnected from the DaaS platform. Later on and after network re-establishment, the consumer starts consuming the service from the same point where it got disconnected, enabling preservation of all user data and settings.
Flow:
• When a disconnected session is noticed, the DaaS platform identifies the related CSC and the virtual desktop. • The DaaS platform checks if user has opted for service continuity, i.e., no loss reconnection. |
+
+**Table III.5 – Service continuation for DaaS**
+
+| Legend | Use case |
+|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| | The DaaS platform saves the required data such as virtual machine data before releasing the resources. On reconnection, the DaaS platform shall look for any saved data and reloads them before resuming the service. |
+| High-level figure describing the use case | Image: Diagram illustrating the service continuation process for DaaS. A user (1) uses the service (1). A session disconnect (2) occurs, marked with a red 'X'. The Cloud service provider (CSP) saves data (3) before releasing resources. Upon reconnection, the CSP reloads data (4) and resumes the session (5), marked with a green checkmark. The user then continues the service (6).
The diagram shows a user interacting with a cloud service provider. The process starts with 'Service usage' (1) where a user icon is shown. This leads to 'Session disconnect' (2), represented by a red circle with a white 'X'. An arrow points from the disconnect point to a cloud containing server icons labeled 'Cloud service provider'. Inside the cloud, an arrow labeled 'Data save' (3) points to the servers. Another arrow labeled 'Data reload' (4) points from the servers back to the cloud. An arrow labeled 'Session resume' (5) points from the cloud to a green circle with a white checkmark. Finally, an arrow labeled 'Service continuation' (6) points from the checkmark back to the user icon.
Y:3503(14)_FIII.5
|
+| Derived requirements | – Resiliency to disaster – Service continuity – Monitoring and controlling DaaS – Maintaining DaaS user status – CSC environment backup – DaaS client reconnection – Display redirection |
+
+**Table III.6 – Home application using DaaS**
+
+| Legend | Use case |
+|----------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Home application using DaaS |
+| Use case description | CSCs access the home applications and data hosted in virtual desktops which are created within a DaaS platform in home. This type of service can support a computer for multi-users with own virtual desktops in small area. CSCs can access their own virtual machine with any DaaS clients through a delivery protocol for virtual desktops in home. Since CSC's access is taken in local area in this application, a certain access protocol can be adopted for the dedicated network or the dedicated DaaS client. CSP can distribute the package for server management and installation to support configuration functions by on-line or off-line ways.
|
+
+**Table III.6 – Home application using DaaS**
+
+| Legend | Use case |
+|-------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| High-level figure describing the use case | Image: Diagram of Home application using DaaS. A house icon contains three client scenarios: a laptop user, a desktop user, and a TV user. These connect via WAN and protocols to a central server rack. A callout box explains the CSP's role in distributing and installing the DaaS server and management function. A detailed view of the 'Virtual desktop server' shows components: VM1, VM4, Connection manager, System manager, HyperVisor, Network card, and Protocol transfer module.
CSP: Distribute on/offline and install DaaS server and management function.
Virtual desktop server
VM1, VM4, Connection manager, System manager, HyperVisor, Network card, Protocol transfer module
Y.3503(14)_FIII.6
|
+| Derived requirements | – Unified management interface – Diversity of DaaS client – Optimized adaptation for content type – Dynamic configuration adaptation – Support of DaaS client peripherals |
+
+**Table III.7 – Charging scheme for DaaS**
+
+| Legend | Use case |
+|----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Use case title | Charging scheme for DaaS |
+| Use case description | This use case depicts the case where charging functionality is required in DaaS. The purpose of this use case is to show various environments of CSCs that use common resources provided by the same CSP.
There are two actors in this diagram: CSC and CSP; they provide software and hardware.
• The CSP needs to manage DaaS user profiles including the types of users. (#1 in figure). • As, depending on the type of users, the rate for using resource can be offered differently, the CSP manages the policy for resource usage. (# 2 in figure). • The CSC uses resources (#3 in figure) and the CSP manages software and hardware usage statics (#4 in figure). • The CSP manages accounting (#5 in figure) by monitoring software and hardware usage statistics (use case 3). The CSC can use storage, CPU and memory as in IaaS, and whenever an application (software) runs on CSP. DaaS also provides storage, CPU and memory. The CSP needs to store accounting information of software and hardware usage whenever the usage occurs. • Considering user profile, software and hardware usage statistics, and the policy of resource usage to reflect different types of usage, the CSP produces bills and requests payment to CSCs (#6 in figure). |
+
+**Table III.7 – Charging scheme for DaaS**
+
+
+
+| Legend | Use case |
+|--------------------------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| High-level figure describing the use case
| graph TD CSC((CSC)) CSP((CSP)) U1(1. Manage user profile) U2(2. Policy for resource usage) U3(3. Use resources) U4(4. Manage S/W and H/W usage statistics) U5(5. Manage accounting) U6(6. Request payment) CSC --- U3 CSP --- U1 CSP --- U4 CSP --- U5 CSP --- U6 CSC --- U4 CSC --- U6 CSC --- U2 CSP --- U2 U3 -.-> <<include>> U4 U4 -.-> <<include>> U1 U5 -.-> <<include>> U1 U5 -.-> <<include>> U4 U6 -.-> <<include>> U2 U6 -.-> <<include>> U3 U6 -.-> <<include>> U5 Y.3503(14)_FIII.7
|
+| Derived requirements
| – Accounting and charging – User account provisioning – User profile management – Server-side platform hardware resource maintenance – Service-related resource maintenance – Status monitoring – System load monitoring – Support for HD and 3D applications – Extensible storage – Resource request – User log management |
+
+UML Use Case Diagram for Charging scheme for DaaS. The diagram shows two actors, CSC and CSP, and six use cases. Use Case 1 (Manage user profile) is associated with CSP. Use Case 2 (Policy for resource usage) is associated with both CSC and CSP. Use Case 3 (Use resources) is associated with CSC. Use Case 4 (Manage S/W and H/W usage statistics) is associated with both CSC and CSP. Use Case 5 (Manage accounting) is associated with CSP. Use Case 6 (Request payment) is associated with both CSC and CSP. Solid arrows show associations: CSC to 3, 4, 6; CSP to 1, 4, 5, 6. Dashed arrows with <> show dependencies: 3 to 4; 4 to 1; 5 to 1; 5 to 4; 6 to 2; 6 to 3; 6 to 5.
+
+# Appendix IV
+
+## Value for response time limit
+
+(This appendix does not form an integral part of this Recommendation.)
+
+The response time is specified in clause 7 as a general requirement for DaaS. The value of the response time-limit is needed in order to meet the CSC's acceptable QoE.
+
+This appendix only provides general information relevant to response time. However, the response time described in here is not specific to cloud computing and DaaS.
+
+Figure IV.1 shows a response time model [b-Shneiderman].
+
+
+
+Y.3503(14)\_FIV.1
+
+Figure IV.1 – Model of response time. A timeline diagram showing the sequence of events in a response time model. The events are: User initiates request, Arrival of user's request, Server begins to process user's request, Server completes processing user's request, Event result delivered, User's device begins response, and User's device completes response. The timeline is divided into five segments: 1) Response time (from User initiates request to User's device begins response), 2) Interaction time (from User initiates request to User's device begins response), 3) Server processing time (from Arrival of user's request to Server completes processing user's request), 4) Transport delay (from User initiates request to Arrival of user's request, and from Server completes processing user's request to Event result delivered), and 5) Render time (from Event result delivered to User's device begins response).
+
+**Figure IV.1 – Model of response time**
+
+As shown in Figure IV.1, the response time includes transport delays, server processing time and rendering time on a client as defined hereafter:
+
+- Response time: An interval from the moment when user initiates an activity until that user's device begins to present its result on the display;
+- Interaction time: The same as response time;
+- Transport delay: An interval from the moment when user's request is sent until it is received by a server or the time from the moment a server sends;
+- Server processing time: Operation time used by a server to process the user's request;
+- Rendering time: Duration for generating an image with the received event results screen on the user's device.
+
+Values for acceptable response times may differ depending on the use case, but experimental studies show that a user starts to be bored or interrupts if there is no response within one second [b-Tolia]. It seems common that users are intolerable if the reaction time takes more than one second.
+
+As shown in Table IV.1 [b-Tolia], in the range from 150 ms to one second users become increasingly aware of the response time, and unhappy after one second.
+
+**Table IV.1 – Impact of interactive response time [b-Tolia]**
+
+| Response time | Subjective impression |
+|--------------------------|------------------------|
+| < 150 ms | Crisp |
+| 150 ms to one second | Noticeable to annoying |
+| One to two seconds | Annoying |
+| Two to five seconds | Unacceptable |
+| Longer than five seconds | Unusable |
+
+# Appendix V
+
+## Service provisioning based on CSC types in DaaS
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix describes the service provisioning based on the various types of cloud service customers. Also, several considerations of the overall service provisioning for DaaS according to the user accounting provisioning are described.
+
+## V.1 Types of cloud service customer
+
+In DaaS, various types of CSC can exist and there are many types of service provisioning according to the type of CSC. Therefore, the classification of CSC is categorized as below:
+
+- Classification based on service level – The CSC can be classified with the various types of service level agreement (SLA).
+- Classification based on virtual desktop environment – The CSC can be classified depending on the types of virtual desktop environment. For example, some CSCs can be serviced with a virtual desktop with OS desktop in itself, and others can be serviced with a web application of virtual desktop. Also, this is related with the type of virtual desktop.
+- Classification based on the allocation of the virtual desktop environment – A CSC can be served with the permanently allocated virtual desktop environment, while others can be served with a temporary virtual desktop in a virtual desktop pool.
+- Classification based on the demand of resources – A CSC can be served with the virtual desktop environment of the predefined configuration or the pre-set virtual image, while others can be served with the virtual desktop environment using CSC manual configuration and resource management.
+
+### V.2 User account provisioning based on CSC types in DaaS
+
+In clause V.1, the various types of CSC are classified. User account provisioning could be implemented in accordance with these types of CSC, and user account should also be provisioned in accordance with service provisioning in DaaS. In general, CSC can request the account in order to use a virtual desktop environment. CSC can be registered by an administrator on the CSP side or the CSC can register the account automatically. The types of user account provisioning for DaaS are listed below.
+
+- Discretionary account provisioning – This account allows administrators to decide for themselves. This approach can be applied to the small office or home application.
+- Self-service account provisioning – This account allows the CSC to participate in some aspects of the provisioning process in order to reduce the administrator's overhead and to quickly supply the virtual desktop environment to the CSC according to the manually requested resources (such as the number of CPU, amount of memory, amount of hard disk resources etc.).
+- Workflow-based account provisioning – This account obtains the approvals from the designated approvers before CSC access. Also, this approach can supply the virtual desktop environments to the CSCs according to the service level with a prior approval.
+- Automatic account provisioning – This requires every account to be added, using one same method, with a centralized management application or data by using the predefined procedures.
+
+### V.3 Service provisioning in DaaS
+
+
+
+```
+graph LR; CSC[CSC type] --> UAP[User account provisioning]; subgraph SP [Service provisioning]; UAP --> SRP[Server resource provisioning]; UAP --> VDP[Virtual desktop provisioning]; UAP --> SWP[Software provisioning]; UAP --> STP[Storage provisioning]; end;
+```
+
+The diagram illustrates the service provisioning process in a DaaS system. It starts with a box labeled 'CSC type' on the left. An arrow points from this box to a box labeled 'User account provisioning' inside a larger box titled 'Service provisioning'. From the 'User account provisioning' box, four arrows branch out to four separate boxes stacked vertically: 'Server resource provisioning', 'Virtual desktop provisioning', 'Software provisioning', and 'Storage provisioning'. All these four boxes are also contained within the 'Service provisioning' box. Below the 'Service provisioning' box, the text 'Y.3503(14)\_FV.1' is written.
+
+Flowchart of Service provisioning in DaaS system
+
+**Figure V.1 – Service provisioning in DaaS system**
+
+As shown in Figure V.1, service provisioning is the design or modification of DaaS configuration to meet the various types of CSC. All types of CSC try to connect their virtual desktop environment with the client and the CSP provides the service in accordance with these types. Service provisioning consists of the following:
+
+- Account provisioning: It makes and manages the CSC account with regard to CSC type.
+- Server and resource provisioning: It supplies or manages hardware resources that are requested from the CSC.
+- Virtual desktop provisioning: It generates, supplies and manages the virtual desktop environment to be allocated to the CSC.
+- Software provisioning: It installs, manages or updates the software in the DaaS platform and virtual desktop environment.
+- Storage provisioning: It manages and backs up offline files of virtual machine, user data and other storage-related files related to virtual desktop environment.
+
+# Bibliography
+
+- [b-ITU-T H.264] Recommendation ITU-T H.264 (2014), *Advanced video coding for generic audiovisual services*.
+- [b-ITU-T H.265] Recommendation ITU-T H.265 (2013), *High efficiency video coding*.
+- [b-ITU-T Y.2201] Recommendation ITU-T Y.2201 (2009), *Requirements and capabilities for ITU-T NGN*.
+- [b-ITU-T Y.2701] Recommendation ITU-T Y.2701 (2007), *Security requirements for NGN release 1*.
+- [b-ITU-T FGCC1] ITU-T Focus Group on Cloud Computing Technical Report (2012), *Part 1: Introduction to the cloud ecosystem: definitions, taxonomies, use cases and high-level requirements*.
+- [b-ITU-T FGCC2] ITU-T Focus Group on Cloud Computing Technical Report (2012), *Part 2: Functional requirements and reference architecture*.
+- [b-IETF RFC 768] IETF RFC 768 (1980), *User Datagram Protocol*.
+- [b-IETF RFC 793] IETF RFC 793 (1981), *Transmission Control Protocol*.
+- [b-IETF RFC 6101] IETF RFC 6101 (1996), *The Secure Sockets Layer (SSL) Protocol Version 3.0*.
+- [b-IETF RFC 6347] IETF RFC 6347 (2012), *Datagram Transport Layer Security Version 1.2*.
+- [b-DMTF OVF] DMTF Standard DSP0243 (2009), *Open virtualization format specification*.
+- [b-W3C-HTML5] W3C, *A vocabulary and associated APIs for HTML and XHTML*, Available at .
+- [b-Shneiderman] Ben Shneiderman (1984), "Response Time and Display Rate in Human Performance with Computers", *ACM Computing Survey*, Vol. 16, pp. 265-285.
+- [b-Tolia] Niraj Tolia, David G. Andersen, and M. Satyanarayanan (2006), "Quantifying Interactive User Experience on Thin Clients", *Computer*, Vol. 39, Issue. 3, pp. 46-52.
+
+
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|--------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | General tariff principles |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Terminals and subjective and objective assessment methods |
+| Series Q | Switching and signalling |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects and next-generation networks |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2f6ecc6f7ac07e563f8788b6bfb2c786ecbfde39
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/18442e4e239480f0c3c95b547aa8fde2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:411caa9ad123cf773f32ed2c4313b217730ae1d7c31e3710f7cf41b9027b16df
+size 60626
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..47d86c320a8fbe1f01c459342fe02f3c23cf2895
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/1d7527f4316cfe2d342b08d1653d1592_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b6fa93b4bd037113eedc113a025fe7a1bd94e7f418f31a8ddbff524ab36d52ba
+size 6822
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c98094b62f5804aa8e100110dcae2c0a1075ee1d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:62d3f98f71bda536de099f2d751f819bf961a48e0dcddcd04292c0dcb4c2e687
+size 60825
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..60e56f0ee7fe854692620a1dcbf8d205a83ea9f2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/c67d21fb3d9042e88cdc669f071b4e7c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0f4a3695a5b8300b1f428bc61589c198d8e67f41ed59ec527bcab6d1a59f6cc0
+size 33056
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..23a50d69f060a63549ed80c265c688e7602da993
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/daa4a6fa7e2ba1954258f86b4928eb32_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4f957ef034799b3bda494ffa54008104054a1c118d08d47296f64172b409479b
+size 62385
diff --git a/marked/Y/T-REC-Y.3523-201908-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..024e7ee7a067867e508662ecfebe480b100911e2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3523-201908-I_PDF-E/raw.md
@@ -0,0 +1,589 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.3523
+
+(08/2019)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Cloud Computing
+
+# --- **Metadata framework for NaaS service lifecycle management**
+
+Recommendation ITU-T Y.3523
+
+ITU-T
+
+
+
+The logo of the International Telecommunication Union (ITU) is located in the bottom right corner. It features a blue globe with a red lightning bolt striking it, and the text "ITU" in blue, with "International Telecommunication Union" in smaller blue text below it.
+
+ITU International Telecommunication Union logo
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|------------------------|----------------------|
+| CLOUD COMPUTING | Y.3500–Y.3999 |
+|------------------------|----------------------|
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|---------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.3523
+
+# Metadata framework for NaaS service lifecycle management
+
+## Summary
+
+Recommendation ITU-T Y.3523 specifies the metadata framework for Network as a Service (NaaS) service lifecycle management in a closed-loop automation environment. This Recommendation is an extension to Recommendations ITU-T Y.3512 and ITU-T Y.3515 as the NaaS series Recommendations. It provides the metadata framework for NaaS service lifecycle management with a highlight on a NaaS operational policy framework.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3523 | 2019-08-13 | 13 | 11.1002/1000/13989 |
+
+## Keywords
+
+Closed-loop automation, lifecycle management, metadata framework, NaaS service, NaaS service operational policy framework.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2019
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|----------------------------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | General description..... | 3 |
+| 7 | Metadata in NaaS service ..... | 4 |
+| | 7.1 NaaS service data model ..... | 4 |
+| | 7.2 NaaS service operational policy data model ..... | 4 |
+| | 7.3 NaaS resource data model ..... | 5 |
+| | 7.4 Relationship among metadata in NaaS service ..... | 5 |
+| 8 | Metadata framework for NaaS service lifecycle management..... | 5 |
+| | 8.1 Metadata of NaaS service in design time ..... | 6 |
+| | 8.2 Metadata of NaaS service in runtime execution time..... | 6 |
+| 9 | NaaS service operational policy framework..... | 6 |
+| | 9.1 Elements of NaaS service operational policy..... | 6 |
+| | 9.2 Functions of NaaS service operational policy ..... | 7 |
+| | 9.3 Procedure of NaaS service operational policy from creation to enforcement ..... | 7 |
+| 10 | Security considerations..... | 8 |
+| | Appendix I – Metadata applicability in NaaS service lifecycle management ..... | 9 |
+| | I.1 Virtual private cloud..... | 9 |
+| | I.2 Instant VPN ..... | 10 |
+| | Bibliography..... | 11 |
+
+
+
+## Recommendation ITU-T Y.3523
+
+# Metadata framework for NaaS service lifecycle management
+
+# 1 Scope
+
+This Recommendation provides the metadata framework for the closed-loop automation lifecycle management of Network as a Service (NaaS) service, specifically in the environments of development and operations (DevOps) and continuous integration/continuous delivery (CI/CD). This Recommendation covers the following aspects:
+
+- general description of metadata for NaaS service lifecycle management;
+- metadata in NaaS service;
+- metadata framework for NaaS service lifecycle management;
+- NaaS service operational policy framework.
+
+This Recommendation also provides Appendix I describing:
+
+- metadata applicability in NaaS service lifecycle management.
+
+NOTE 1 – The objective in defining a metadata framework of NaaS service lifecycle management is not to invent new metadata, but rather to make the existing metadata interoperable and integrated in the closed-loop automation management of NaaS service, especially in the environments of DevOps and CI/CD.
+
+NOTE 2 – "Metadata" in this Recommendation refers to NaaS service data model, NaaS service operational policy data model and NaaS resource data model.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T X.1601] Recommendation ITU-T X.1601 (2015), *Security framework for cloud computing*.
+- [ITU-T Y.3512] Recommendation ITU-T Y.3512 (2014), *Cloud computing – Functional requirements of Network as a Service*.
+- [ITU-T Y.3515] Recommendation ITU-T Y.3515 (2017), *Cloud computing – Functional architecture of Network as a Service*.
+- [ITU-T Y.3522] Recommendation ITU-T Y.3522 (2016), *End-to-end cloud service lifecycle management requirements*.
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 cloud computing** [b-ITU-T Y.3500]: Paradigm for enabling network access to a scalable and elastic pool of shareable physical or virtual resources with self-service provisioning and administration on-demand.
+
+NOTE – Examples of resources include servers, operating systems, networks, software, applications and storage equipment.
+
+**3.1.2 cloud service** [b-ITU-T Y.3500]: One or more capabilities offered via cloud computing invoked using a defined interface.
+
+**3.1.3 cloud service customer** [b-ITU-T Y.3500]: Party which is in a business relationship for the purpose of using cloud services.
+
+NOTE – A business relationship does not necessarily imply financial agreements.
+
+**3.1.4 cloud service provider** [b-ITU-T Y.3500]: Party which makes cloud services available.
+
+**3.1.5 Network as a Service (NaaS)** [b-ITU-T Y.3500]: Cloud service category in which the capability provided to the cloud service customer is transport connectivity and related network capabilities.
+
+**3.1.6 network function** [ITU-T Y.3515]: A function of a network infrastructure whose external interfaces and functional behaviour are well specified.
+
+NOTE – Examples of network functions include network switches and network routers.
+
+**3.1.7 network service** [ITU-T Y.3515]: A collection of network functions with a well specified behaviour.
+
+NOTE – Examples of network services include content delivery networks (CDNs) and IP multimedia subsystem (IMS).
+
+**3.1.8 software-defined networking** [b-ITU-T Y.3300]: A set of techniques that enables to directly program, orchestrate, control and manage network resources, which facilitates the design, delivery and operation of network services in a dynamic and scalable manner.
+
+## 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 NaaS service operational policy administration point (NPAP):** An entity in the Network as a Service (NaaS) service operational policy framework that administrates the policies.
+
+**3.2.2 NaaS service operational policy decision point (NPDP):** An entity in the Network as a Service (NaaS) service operational policy framework that makes authorization decisions and distributions of the policies.
+
+**3.2.3 NaaS service operational policy enforcement point (NPEP):** An entity in the Network as a Service (NaaS) service operational policy framework that implements the decisions of NPDP (3.2.2).
+
+**3.2.4 NaaS service operational policy information point (NPIP):** An entity in the Network as a Service (NaaS) service operational policy framework that stores the policies.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|----------------------------|
+| CI | Continuous Integration |
+| CD | Continuous Delivery |
+| CDN | Content Delivery Network |
+| CE | Customer Edge |
+| CSC | Cloud Service Customer |
+| CSP | Cloud Service Provider |
+| DevOps | Development and Operations |
+
+| | |
+|------|------------------------------------------------------|
+| ECA | Event, Condition and Action |
+| IMS | IP Multimedia Subsystem |
+| NaaS | Network as a Service |
+| NF | Network Function |
+| NPAP | NaaS Service Operational Policy Administration Point |
+| NPDP | NaaS Service Operational Policy Decision Point |
+| NPEP | NaaS Service Operational Policy Enforcement Point |
+| NPIP | NaaS Service Operational Policy Information Point |
+| NS | Network Service |
+| OSS | Operation Support System |
+| PE | Provider Edge |
+| SDN | Software-Defined Networking |
+| VM | Virtual Machine |
+| VPC | Virtual Private Cloud |
+| VPN | Virtual Private Network |
+
+# 5 Conventions
+
+The keywords "**is required to**" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+In the body of this Recommendation and its annexes, the words shall, shall not, should, and may sometimes appear, in which case they are to be interpreted, respectively, as is required to, is prohibited from, is recommended, and can optionally. The appearance of such phrases or keywords in an appendix or in material explicitly marked as informative is to be interpreted as having no normative intent.
+
+# 6 General description
+
+The increasing demands on the closed-loop automation management of cloud service causes methods and technology widely used in information technology (IT) like DevOps and CI/CD to be considered and adopted by the telecommunications industry.
+
+The existing initiative aims to enable operational processes and tasks (e.g., delivery, deployment, configuration, assurance and optimization) to be executed automatically, such as ETSI ZSM ISG [b-ZSM], or to provide a comprehensive platform for real-time, policy-driven orchestration and automation of physical and virtual network functions (NFs), like open source open network automation platform (ONAP) [b-ONAP].
+
+According to [ITU-T Y.3522], the complexity of re-design, re-configuration and re-deployment problems can be addressed through cloud service lifecycle management metadata. A new service can be created with changes only in metadata, which can be regarded as the linkage between design time and execution time. Taking NaaS service as an example, whose functional requirements and architecture are well defined in [ITU-T Y.3512] and [ITU-T Y.3515], the related metadata has been defined in several different standards developing organizations (SDOs) and used in many network areas.
+
+However, there is no specification to address the detailed position and function of metadata in the context of the entire closed-loop automation lifecycle management of the NaaS service, whose dependencies and constraints vary unavoidably.
+
+This Recommendation specifies the interoperability and integration of the existing NaaS-related data models as a typical kind of Anything as a Service (XaaS). Although, there are other activities on data models' development on NaaS service aspect (e.g., OASIS TOSCA [b-TOCSA], IETF YANG [b-YANG], OASIS BPEL [b-BPEL]), this Recommendation is focused on specifying the framework with attention on policy aspects, and applicability of data models in closed-loop automation management of NaaS service.
+
+# 7 Metadata in NaaS service
+
+This clause aims to specify the positions and functions of NaaS service metadata for the entire lifecycle management. The positions of NaaS-related data models are illustrated as shown in Figure 7-1.
+
+
+
+The diagram illustrates the positions of NaaS-related metadata. It is divided into two main sections: 'Service layer' and 'Operational support systems'.
+ In the 'Service layer', there is a box for 'Service capabilities (NaaS)' which contains two sub-boxes: 'NaaS service data model' and 'NaaS service operational policy data model'. Below this is a box for 'Resource layer' containing a cloud icon labeled 'Physical and virtualized resources'.
+ In the 'Operational support systems', there is a box for 'OSS-NaaS' which contains a 'Service catalogue' box. The 'Service catalogue' box contains three sub-boxes: 'NaaS service data model', 'NaaS service operational policy data model', and 'NaaS resource data model'.
+ The label 'Y.3523(19)\_F7-1' is located at the bottom right of the diagram.
+
+Figure 7-1: Illustration of NaaS-related metadata positions. The diagram shows two main components: 'Service layer' and 'Operational support systems'. The 'Service layer' contains 'Service capabilities (NaaS)' which includes 'NaaS service data model' and 'NaaS service operational policy data model', and a 'Resource layer' containing 'Physical and virtualized resources'. The 'Operational support systems' contain 'OSS-NaaS' which includes a 'Service catalogue' containing 'NaaS service data model', 'NaaS service operational policy data model', and 'NaaS resource data model'.
+
+**Figure 7-1 – Illustration of NaaS-related metadata positions**
+
+Operation support system (OSS)-NaaS service catalogue functional components (see clause 8.3.1 of [ITU-T Y.3515]) includes a listing of all cloud services of NaaS cloud service providers (CSPs) including the relevant NaaS services. NaaS service data model, NaaS service operational policy data model and NaaS resource data model are needed in this functional component for NaaS service instantiation.
+
+The service capabilities (NaaS) functional component (see clause 8.2.3 of [ITU-T Y.3515]) in the service layer provides capabilities exposed to the NaaS cloud service customer (CSC) according to the NaaS service data model and NaaS service operational policy data model selected by the NaaS CSC through business level interactions with the NaaS CSP.
+
+## 7.1 NaaS service data model
+
+The NaaS service data model (see clause 8.3.1 of [ITU-T Y.3515]) describes the specific network service based on the characteristic of the service that can be used for service delivery, e.g., L3VPN and L2VPN data models under development of the working groups L3SM [b-L3SM] and L2SM [b-L2SM] of IETF.
+
+## 7.2 NaaS service operational policy data model
+
+The NaaS service operational policy data model (see clause 8.3.1 of [ITU-T Y.3515]) describe high-level network-wide polices for a given NaaS service, which can be input into the network management function (within a software-defined networking (SDN) controller, an orchestrator, or a network element), and combined with the NaaS service data model and mapped into a target configuration of
+
+network elements, e.g., generic policy data model described in [b-SUPA] of IETF. The network management function can control the configuration and monitor the network elements and services according to such policies.
+
+## 7.3 NaaS resource data model
+
+The NaaS resource data model (see clause 8.3.1 of [ITU-T Y.3515]) describes topology of NaaS CSP's resources across different layers and reflects the attributes and operational parameters of given NaaS resources (e.g., network services (NSs), NFs, virtualised resources, physical resources).
+
+## 7.4 Relationship among metadata in NaaS service
+
+The NaaS service operational policy data model can manage and adjust service behaviours as necessary. The NaaS service operational policy data model and the NaaS service data model have a one-to-many relationship.
+
+The NaaS service operational policy data model can manage and adjust resources behaviour as necessary. The NaaS service operational policy data model and the NaaS resource data model have a one-to-many relationship.
+
+# 8 Metadata framework for NaaS service lifecycle management
+
+This clause aims to specify the metadata framework in NaaS service lifecycle management by reflecting the interoperability and integration of the NaaS service metadata, especially in the environments of DevOps and CI/CD.
+
+As described in [ITU-T Y.3522], metadata is used in the entire cloud service lifecycle management, from design, deployment, operation, to retirement stages. For NaaS service, closed-loop automation management is achieved by using data models of NaaS service, NaaS service operational policy, and NaaS resource, as a linkage, in the four iterative stages of NaaS service lifecycle management. These four iterative stages can be categorized into design time, including design stage, and runtime execution time, including deployment stage, operation stage and retirement stage.
+
+Figure 8-1 depicts the metadata framework for NaaS service lifecycle management. The metadata of NaaS service is created in design time, and then distributed to runtime execution time to be used in implementing a metadata-driven service deployment, operation and retirement. The feedback from runtime execution time to design time is to help identify the changes needed for the metadata.
+
+
+
+```
+
+graph LR
+ subgraph Design_time [Design time]
+ Design[Design]
+ MetaD[Metadata of NaaS service]
+ Design -- Create --> MetaD
+ end
+
+ subgraph Runtime_execution_time [Runtime execution time]
+ subgraph Stages [NaaS service life cycle management stages]
+ Deployment[Deployment] --> Operation[Operation] --> Retirement[Retirement]
+ end
+ MetaR[Metadata of NaaS service]
+ end
+
+ Design -- "Metadata distribution" --> Deployment
+ Retirement -- "Feedback for metadata modification" --> Design
+ MetaR -- "Metadata-Driven NaaS service deployment, operation and retirement" --> Deployment
+ MetaR --> Operation
+ MetaR --> Retirement
+
+```
+
+Y.3523(19)\_F8-1
+
+Figure 8-1: Metadata framework for NaaS service lifecycle management. The diagram is divided into two main sections: 'Design time' and 'Runtime execution time'. In 'Design time', a 'Design' stage (rectangle) leads to 'Metadata of NaaS service' (oval) via a 'Create' arrow. In 'Runtime execution time', a dashed box labeled 'NaaS service life cycle management stages' contains 'Deployment', 'Operation', and 'Retirement' stages (rectangles) connected by right-pointing arrows. A 'Metadata of NaaS service' oval is at the bottom. A 'Metadata distribution' arrow points from the 'Design' stage to the 'Deployment' stage. A 'Feedback for metadata modification' arrow points from the 'Retirement' stage back to the 'Design' stage. A 'Metadata-Driven NaaS service deployment, operation and retirement' arrow points from the 'Metadata of NaaS service' oval up to the 'Deployment', 'Operation', and 'Retirement' stages. A legend at the bottom indicates that rectangles represent 'Stage' and ovals represent 'Metadata'. The reference 'Y.3523(19)\_F8-1' is at the bottom right.
+
+**Figure 8-1 – Metadata framework for NaaS service lifecycle management**
+
+## **8.1 Metadata of NaaS service in design time**
+
+Models of NaaS service, NaaS service operational policy, and NaaS resource are created and developed in design time for making services and resources available, using modelling tools provided by NaaS CSP. The modelling process will not trigger any NaaS service instantiation in the runtime execution environment until the OSS-NaaS receives a request to do so.
+
+The basic extendable model templates are defined and stored in service catalogue of OSS-NaaS (NaaS service data model and NaaS service operational policy data model) and network controller (NaaS resource data model) during design time and can be configured and extended with additional parameters, parameter value ranges and validation rules according to NaaS CSC's request.
+
+## **8.2 Metadata of NaaS service in runtime execution time**
+
+The modelled NaaS service is instantiated in runtime execution time and the specific NaaS service model and its NaaS service operational policy data model drive the corresponding codes. The active NaaS service is continuously monitored by event listening. The event, requiring healing and/or scaling based on real-time NaaS CSC requests, is responded to based on the associated condition pre-defined in NaaS service operational policy data model.
+
+Based on the monitoring data collected during runtime execution time, the patterns governing usage, thresholds, events, policy effectiveness, etc., are discerned and the necessary feedback to effect modelling changes in design time is enabled.
+
+# **9 NaaS service operational policy framework**
+
+This clause aims to present the NaaS service operational policy framework which consists of elements and functions provided by the CSP and the corresponding procedure.
+
+### **9.1 Elements of NaaS service operational policy**
+
+NaaS service operational policy data models are operated from creation to execution in the NaaS service operational policy framework. The main elements of the NaaS service operational policy framework are described as follows.
+
+#### **9.1.1 NaaS service operational policy administration point**
+
+The NaaS service operational policy administration point (NPAP) is responsible for the creation, translation, and validation of new NaaS service operational policy data models, and the modification of existing ones, both during design time and runtime execution time. NaaS service operational policy data models are created with the integration of NaaS service data models.
+
+#### **9.1.2 NaaS service operational policy decision point**
+
+The NaaS service operational policy decision point (NPDP) is responsible for the distribution and decisions of NaaS service operational policy data models. Once the NaaS service operational policy data model is initially created or an existing one is modified, the NPDP sends it from the repository to the NaaS service operational policy enforcement point (NPEP) before it is actually needed. In this distributed manner, NaaS service operational policy data models will be available when needed in order to minimize the latency for real-time requests or triggers to the NPDP. In some required cases, NaaS service operational policy data models can be subscribed and automatically updated on the NPEP.
+
+#### **9.1.3 NaaS service operational policy information point**
+
+The NaaS service operational policy information point (NPIP) is responsible for storing new NaaS service operational policy data models in the repository which are verified by the NPAP. The existing ones can be retrieved in the repository.
+
+In the repository, NaaS service operational policy data models are grouped by different dimensions, which include, but are not limited to, the corresponding NaaS service data model, the type or category, the lifecycle, the ownership or administrative domain, the geographic area or location, the technology type, the describing language and version, and the security level.
+
+#### 9.1.4 NaaS service operational policy enforcement point
+
+The NPEP is responsible for the enforcement of NaaS service operational policy data models during the runtime execution time.
+
+## 9.2 Functions of NaaS service operational policy
+
+Table 9-1 provides descriptions of the main functions related to the NaaS service operational policy data model.
+
+**Table 9-1 – Functions related with NaaS service operational policy data model**
+
+| No. | Function | Description |
+|-----|-------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| 1 | Create policy | The CSP creates a NaaS service operational policy data model on the NPAP based on the required policy parameters and the NPIP stores it with the allocated labels which indicates its dimensions. |
+| 2 | Delete policy | The CSP deletes the specified NaaS service operational policy data model on the NPAP and the NPIP removes it from the repository. |
+| 3 | Update policy | The CSP updates a NaaS service operational policy data model on the NPAP based on the new policy parameters and the NPIP re-stores it and the original one is overwritten accordingly. |
+| 4 | Get policy | The NPDP requests the specified NaaS service operational policy data model from the NPIP and gets it from the repository. |
+| 5 | Distribute policy | The NPDP distributes the specified NaaS service operational policy data model to the NPEP and the NPEP makes the subscription on the NPDP for its update. |
+| 6 | List policy | The NPIP lists all the NaaS service operational policy data models on demand. |
+| 7 | Retrieve policy | The NPIP provides the retrieved NaaS service operational policy data models on demand based on the specified retrieval conditions. |
+| 8 | Enforce policy | The NPEP enforces the NaaS service operational policy data models based on the trigger condition or request. |
+
+## 9.3 Procedure of NaaS service operational policy from creation to enforcement
+
+The interactions among the main elements of NaaS service operational policy framework from creation to enforcement of the policy data model are described as follows in Figure 9-1.
+
+
+
+```
+
+sequenceDiagram
+ participant CSP
+ participant NPAP
+ participant NPIP
+ participant NPDP
+ participant NPEP
+
+ CSP->>NPAP: 1. Design and create the policy data model
+ NPAP->>NPIP: 2. Request the store of the policy data model
+ NPIP-->>NPAP: 3. ACK
+ NPIP->>NPIP: 4. Store the policy data model
+ NPDP->>NPIP: 5. Request the policy data model
+ NPIP-->>NPDP: 6. ACK
+ NPDP->>NPIP: 7. Make decision of policy data model usage
+ NPDP->>NPEP: 8. Distribute the policy data model
+ NPEP-->>NPDP: 9. ACK
+ NPEP->>NPEP: 10. Enforce the policy data model
+
+```
+
+Y.3523(19)\_F9-1
+
+Sequence diagram showing the procedure from creation to enforcement of the NaaS service operational policy data model. The diagram involves five entities: CSP, NPAP, NPIP, NPDP, and NPEP. The steps are: 1. CSP designs and creates the policy data model on NPAP. 2. NPAP requests the NPIP to store the model. 3. NPIP sends an ACK to NPAP. 4. NPIP stores the model. 5. NPDP requests the model from NPIP. 6. NPIP sends an ACK to NPDP. 7. NPDP makes a decision on usage. 8. NPDP distributes the model to NPEP. 9. NPEP sends an ACK to NPDP. 10. NPEP enforces the model.
+
+**Figure 9-1 – Procedure from creation to enforcement of the NaaS service operational policy data model**
+
+- 1) The CSP designs and creates the NaaS service operational policy data model on NPAP.
+- 2) The NPAP requests the NPIP to store the newly created NaaS service operational policy data model.
+- 3) The NPIP sends an acknowledgement to the NPAP.
+- 4) The NPIP stores the newly created NaaS service operational policy data model in the repository.
+- 5) The NPDP requests the NaaS service operational policy data model from the NPIP for decision.
+- 6) The NPIP sends an acknowledgement to the NPDP.
+- 7) The NPDP decides how to deal with the NaaS service operational policy data model.
+- 8) The NPDP distributes the NaaS service operational policy data model to the NPEP which subscribed it.
+- 9) The NPEP sends an acknowledgement to the NPDP.
+- 10) The NPEP enforces the NaaS service operational policy data model once it is triggered.
+
+# 10 Security considerations
+
+Security aspects for consideration within the cloud computing environment, including inter-cloud computing, are addressed by security challenges for CSPs as described in [ITU-T X.1601]. [ITU-T X.1601] analyses security threats and challenges, and describes security capabilities that could mitigate these threats and meet the security challenges. This Recommendation does not introduce any new security issues.
+
+# Appendix I
+
+## Metadata applicability in NaaS service lifecycle management
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix aims to provide applicability examples of NaaS service lifecycle management metadata.
+
+### I.1 Virtual private cloud
+
+The manipulation of the virtual private cloud (VPC) network may also affect the configuration of physical networks. For example, when two new virtual machines (VMs) associated to a given VPC are deployed in two different data centres (DCs), the VPC control mechanism needs to generate a virtual private network (VPN) between these two data centres for the internal VPC communications. Therefore, the control mechanism for a VPC should be able to adjust the underlying network at run time when a CSC requests changes to the VPC network or service deployment.
+
+When a CSC moves from one location to another, which is near to another CSP's data centre, and in the case where the network load between these two data centres is low, the CSC's VM(s) should be migrated to the new data centre to allow for a better user experience.
+
+As illustrated by Figure I.1, a VPC corresponds to a combination of cloud computing resources with a VPN infrastructure to give NaaS service CSCs the abstraction of a private set of cloud resources that are transparently and securely connected to their own infrastructure. VPCs are created by taking dynamically configurable pools of cloud resources and connecting them to enterprise sites with VPNs.
+
+
+
+The diagram shows two cloud shapes representing data centres. The left cloud is labeled 'Enterprise data centre' and contains six rectangular boxes, each labeled 'VM'. The right cloud is labeled 'Public cloud' and contains a smaller circle labeled 'VPC', which in turn contains two rectangular boxes labeled 'VM'. A central cloud shape labeled 'VPN service' is connected to both the Enterprise data centre and the Public cloud by horizontal lines.
+
+Diagram illustrating a Virtual Private Cloud (VPC) setup. On the left, an 'Enterprise data centre' cloud contains six VMs. On the right, a 'Public cloud' contains a 'VPC' which in turn contains two VMs. A 'VPN service' cloud connects the Enterprise data centre and the Public cloud.
+
+Y.3523(19)\_FI.1
+
+**Figure I.1 – Illustration of virtual private cloud**
+
+The NaaS resource data model needs to be used in this scenario for modelling the physical nodes and links.
+
+The NaaS service data model, specifically for L3VPN, is needed to model the L3VPN attributes, including, but not limited to: tenant ID, VPN site IDs, VPN type, access bandwidth.
+
+Here, the NaaS policy data model can be described as follows, using event, condition and action (ECA) policy.
+
+- Event: a VPC user's location is changed (near to another DC)
+- Condition: $\text{network\_load}(\text{DC\_old}, \text{DC\_new}) < \text{threshold}$
+- Action:
+ - 1) migrate the VM to the new data center (DC\_new);
+ - 2) update the VPNs connecting the CSC's services.
+
+### **I.2 Instant VPN**
+
+Traditionally, when a NaaS CSP needs to deploy VPN services for an enterprise NaaS CSC, the NaaS CSP will send service staff to the NaaS CSC site to make the wired connection between the customer edge (CE) and provider edge (PE) devices. The service staff also collects configuration information such as port/frame/slot of PE and the PE ID, and then sends the collected information back to the management system. The management system then configures the network according to this information, as well as the NaaS CSC's information (e.g., bandwidth, SLA). The problem with this approach is that the service staff needs to collect the connection information and feed it back to the management system, and they must make sure that the collected information matches the actual connection. This process is error prone.
+
+New approaches should not count on the physical/geographical information feedback by the service staff and should minimize the operational procedures. The CE should send an authentication request (with credentials) to the PE, and the PE should forward the request to the management system, together with the port/frame/slot on which the request is received, the PE ID, etc. The goal is that NaaS CSP configures a VPN for an enterprise NaaS CSC to connect its enterprise network. The NaaS resource data model needs to be used in this scenario for modelling the physical nodes and links.
+
+The NaaS service data model, specifically for L3VPN, is needed to model the L3VPN attributes, including, but not limited to: tenant ID, VPN site IDs, VPN type and access bandwidth.
+
+Here, the NaaS policy data model can be described as follows, using ECA policy.
+
+- Event: service management system receives a CE request for VPN creation (forwarded by PE);
+- Condition: authentication and authorization results are acknowledged;
+- Action: configure a VPN based on received requests, including the NaaS CSC's grade and physical information (port/slot/frame/route id, etc.) from which the request is received.
+
+# Bibliography
+
+- [b-ITU-T Y.3300] Recommendation ITU-T Y.3300 (2014), *Framework of software-defined networking*.
+- [b-ITU-T Y.3500] Recommendation ITU-T Y.3500 (2014) | ISO/IEC 17788:2014, *Information technology – Cloud computing – Overview and vocabulary*.
+- [b-BPEL] OASIS BPEL 2.0 (2007), *Web Services Business Process Execution Language Version 2.0*.
+<> (last accessed 28 June 2019)
+- [b-L2SM] IETF RFC 8466 (2018), *A YANG Data Model for Layer 2 Virtual Private Network (L2VPN) Service Delivery*.
+- [b-L3SM] IETF RFC 8299 (2018), *YANG Data Model for L3VPN Service Delivery*.
+- [b-ONAP] ONAP, *Open Network Automation Platform*.
+(Referenced 28 06 2019).
+- [b-SUPA] IETF RFC 8328 (2018), *Policy-Based Management Framework for the Simplified Use of Policy Abstractions (SUPA)*.
+- [b-TOCSA] OASIS TOSCA 1.0 (2013), *Topology and Orchestration Specification for Cloud Applications Version 1.0*.
+<> (last accessed 28 June 2019)
+- [b-YANG] IETF RFC 6020 (2010), *YANG – A Data Modeling Language for the Network Configuration Protocol (NETCONF)*.
+- [b-ZSM] ETSI ISG ZSM, *Industry Specification Group Zero touch network and Service Management*.
+<> (last accessed 28 June 2019)
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/052828841894e42527af88a5b40c01b6_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/052828841894e42527af88a5b40c01b6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2b4bfdf7a121ef90cefca017048a45f2ab59719f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/052828841894e42527af88a5b40c01b6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0cc7827ff7e27c361ae7bce0113669ce4d30b20fd0add6366e63866d8addd4db
+size 40147
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..954c39740d118af8b9b3af5266f87dab242eb3bc
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/5e92d9e8e9ce204e405bff2367f88176_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b62d778814850ae7cd9b9ccea82cc2ed78bd3e9421194bd46a89e100d6cf3b2d
+size 44048
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/60d7b6ea740a57867bf69906fc0c2bd6_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/60d7b6ea740a57867bf69906fc0c2bd6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..54ceb8789a4d751d5c717fd5ee52967da23521b9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/60d7b6ea740a57867bf69906fc0c2bd6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8a32274cdad99d3f2dd848cb58e8d22facc921eb57702ce8bda943fb72a7610f
+size 74046
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/9461d066dfa719ad9b1dd2d11dc592c3_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/9461d066dfa719ad9b1dd2d11dc592c3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dfde36d19903452f54c11058ce8de19ce9ac15bd
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/9461d066dfa719ad9b1dd2d11dc592c3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6320439dd14a921345a0289c9a371c4e6b9a2b4db0f94b0389c77a5948db9a02
+size 46923
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a14241c894c6c73cb7e0665044db362f_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a14241c894c6c73cb7e0665044db362f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..03852cd6e4d1583ed25029436988129d34775521
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a14241c894c6c73cb7e0665044db362f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1593a06d718019baa6df7e8bbf38f17f3ce487d0e0f1e05435786900f2a15a57
+size 46629
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a234352dfaccdc24745c88eef7724cc6_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a234352dfaccdc24745c88eef7724cc6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d65924626de20d6dc42046bb93aaf9fd29f011ae
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/a234352dfaccdc24745c88eef7724cc6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d302ec5cf93b14704b5595a3bdb8e6dd356d2d69def3669027882aa4b4a12147
+size 105072
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b630650a9a996ed7c3b5f97d2df12bbc2ff1a5c0
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ecb94bc50eef2573d19d914a3d333c22e8932b0666a805005bbea7c23ca8b64d
+size 47480
diff --git a/marked/Y/T-REC-Y.3532-202305-I_PDF-E/f8d65f2074ad9b6ee00794f35e31433b_img.jpg b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/f8d65f2074ad9b6ee00794f35e31433b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a6a8a82211352241c6516889d216d23fef04c2c8
--- /dev/null
+++ b/marked/Y/T-REC-Y.3532-202305-I_PDF-E/f8d65f2074ad9b6ee00794f35e31433b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9583eac89a88c87cdc6bb41983fc98ae1a56bd5aaeabc390f282d31cd45648ae
+size 63060
diff --git a/marked/Y/T-REC-Y.3600-201511-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..36a79516a0636a7baf85f90a4319571dc2e00f16
--- /dev/null
+++ b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:56bb0b01f182d0c5b150179ff1c8209abdd717d735d689b1843d7ab11d9c2bcd
+size 65550
diff --git a/marked/Y/T-REC-Y.3600-201511-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b9fdbd07b78092184706ed4170d9ce8c5b5a7883
--- /dev/null
+++ b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/73b5cce955ba9415a98791db7b0080ad_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b20f28023563db1839e3974e8a41472475d66022a6aa85adb517872e9e8d954b
+size 215395
diff --git a/marked/Y/T-REC-Y.3600-201511-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..baddd29856da5fd820ccab59a80e758e4c8e80ce
--- /dev/null
+++ b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/84a1d09fb489061482111515543b60dc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:07904a20d14bdd46d58876db0a7746c5b49409081ce3304dad2901bcb86ea01b
+size 6861
diff --git a/marked/Y/T-REC-Y.3600-201511-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..db6a501e468ba35db38f968a5077b6c85f224587
--- /dev/null
+++ b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d5f8b01679865de3bb9197bbb8a0a4067bafdb033e63e77d20e8fbdf112d6fcd
+size 114450
diff --git a/marked/Y/T-REC-Y.3600-201511-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..de0bc53b86db542b45b985fe6f8425b0328da550
--- /dev/null
+++ b/marked/Y/T-REC-Y.3600-201511-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d6879ddaed9735c3026e6b4bb3d04bf0b9b7092d9c77b6396e8114c6c2a50e57
+size 38584
diff --git a/marked/Y/T-REC-Y.3604-202002-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.3604-202002-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..61f030609bb4fd47e6bb863bf33c14f7655c097e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/5cab96b2d23174c25919840ecd50aa48_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bae44fc2e0b09534a5d0a5746fe36e02f3e9ede2f6cdcf95734511290f9e439e
+size 107597
diff --git a/marked/Y/T-REC-Y.3604-202002-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b863142ef1634b6ea0640ee2856e96650ec584e3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/b9ecbc3baefab13719e000faa6e0c7eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0972d06c8aacf4bbb6d7164f27d49d90dd03b0bccb165aaee734e6a5fd500d68
+size 98426
diff --git a/marked/Y/T-REC-Y.3604-202002-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a7a0b60130acf42e042f1ff7b4e0e47fa1a7301c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bbe5ab8645229c645304c48558926caabac62a312cee453c9f96d138e2f6709d
+size 150662
diff --git a/marked/Y/T-REC-Y.3604-202002-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6a0ef87e9da65e8586716e09a7bc2018a7d5f6e3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3604-202002-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:dbb0c3ca1d839e6e71331a8d0110e850e2a91dce43b85dd204145fa1644a68dd
+size 45637
diff --git a/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8423857338c7943fb53f6d62820e1de9b67a04e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:da9f8de1f3eacbe3b5a5a51aa159e69515d35956d070ed38c2839f2d3b43bc36
+size 4216
diff --git a/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c47170213980cba7e9d70a4f6d5a71096e6e2796
--- /dev/null
+++ b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/a734898ce18e972938949637c32a34f4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:29e1186874f2bc7f91ffaa5c085f5c65424e4e03ff2134468bb930db8b0a713c
+size 28655
diff --git a/marked/Y/T-REC-Y.3652-202006-I_PDF-E/raw.md b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..f1d4f4e1515550c3fb40701bec2eea0099dfe0ad
--- /dev/null
+++ b/marked/Y/T-REC-Y.3652-202006-I_PDF-E/raw.md
@@ -0,0 +1,659 @@
+
+
+I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.3652
+
+(06/2020)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Big Data
+
+# --- **Big data driven networking – requirements**
+
+Recommendation ITU-T Y.3652
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+# GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+| | |
+|--------------------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | |
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+| INTERNET PROTOCOL ASPECTS | |
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+| NEXT GENERATION NETWORKS | |
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+| FUTURE NETWORKS | Y.3000–Y.3499 |
+| CLOUD COMPUTING | Y.3500–Y.3599 |
+| BIG DATA | Y.3600–Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800–Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | |
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.3652
+
+## Big data driven networking – requirements
+
+## Summary
+
+Big data driven networking (bDDN) is a group of technologies and methods to facilitate network operation, administration, maintenance and optimization, etc. based on the big data generated by the network and a series of methods and tools. That is to say, big data generated by the network are used to serve the network and make the network better.
+
+Recommendation ITU-T Y.3652 specifies requirements of big data driven networking. This Recommendation studies general requirements for big data driven networking, requirements of big data plane for big data driven networking, requirements of network plane for big data driven networking, requirements of management plane for big data driven networking and interface requirements for big data driven networking.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.3652 | 2020-06-22 | 13 | 11.1002/1000/14256 |
+
+## Keywords
+
+Big data driven networking, requirements.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2020
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|--------------------------------------------------------------------------------|-------------|
+| 1 | Scope ..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | General requirements for big data driven networking..... | 3 |
+| | 6.1 General functional requirements ..... | 3 |
+| | 6.2 General performance requirements ..... | 4 |
+| 7 | Requirements of big data plane for bDDN ..... | 5 |
+| | 7.1 Requirements of network big data collection for bDDN..... | 5 |
+| | 7.2 Requirements of network big data repository ..... | 7 |
+| | 7.3 Requirements of network big data analysing ..... | 7 |
+| | 7.4 Requirements of network big data service ..... | 8 |
+| 8 | Requirements of network plane for big data driven networking..... | 10 |
+| | 8.1 Requirements of network application layer..... | 10 |
+| | 8.2 Requirements of network control layer ..... | 10 |
+| | 8.3 Requirements for network infrastructure layer..... | 11 |
+| 9 | Requirements of management plane for big data driven networking..... | 11 |
+| | 9.1 Network marketing operation..... | 11 |
+| | 9.2 Network planning and engineering ..... | 12 |
+| 10 | Interface requirements for big data driven networking ..... | 12 |
+| | 10.1 Requirements for interfaces between layers of big data plane ..... | 12 |
+| | 10.2 Requirements for interface between big data plane and network plane ..... | 13 |
+| | 10.3 Requirements for interface between big data plane and management plane.. | 13 |
+| | 10.4 Requirements for interface between domains of big data plane..... | 14 |
+| 11 | Security considerations..... | 14 |
+
+
+
+# Recommendation ITU-T Y.3652
+
+## Big data driven networking – requirements
+
+# 1 Scope
+
+This Recommendation specifies requirements of big data driven networking.
+
+The scope of this Recommendation includes:
+
+- general requirements for big data driven networking;
+- requirements of big data plane for big data driven networking;
+- requirements of network plane for big data driven networking;
+- requirements of management plane for big data driven networking;
+- interface requirements for big data driven networking;
+- security aspect requirements for big data driven networking.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+| | |
+|----------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T X.200] | Recommendation ITU-T X.200 (1994) ISO/IEC 7498-1:1994, Information technology. Open Systems Interconnection. Basic Reference Model: The basic model. |
+| [ITU-T X.731] | Recommendation ITU-T X.731 (1992) ISO/IEC 10164-2:1993, Information technology – Open Systems Interconnection – Systems management: State management function. |
+| [ITU-T Y.1221] | Recommendation ITU-T Y.1221 (2010), Traffic control and congestion control in IP-based networks. |
+| [ITU-T Y.2704] | Recommendation ITU-T Y.2704 (2010), Security mechanisms and procedures for NGN. |
+| [ITU-T Y.2770] | Recommendation ITU-T Y.2770 (2012), Requirements of deep packet inspection in next generation networks. |
+| [ITU-T Y.2771] | Recommendation ITU-T Y.2771 (2014), Framework for deep packet inspection. |
+| [ITU-T Y.3650] | Recommendation ITU-T Y.3650 (2018), Framework of big-data-driven networking. |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following term defined elsewhere:
+
+**3.1.1 big data driven networking (bDDN)** [ITU-T Y.3650]: A type of future network framework that collects big data from networks and applications, and generates big data intelligence based on the big data; it then provides big data intelligence to facilitate smarter and autonomous network management, operation, control, optimization and security, etc.
+
+## **3.2 Terms defined in this Recommendation**
+
+This Recommendation defines the following term:
+
+**3.2.1 API gateway:** A server that is the single-entry point into the system.
+
+NOTE – The application programming interface (API) gateway encapsulates the internal system architecture and provides an API that is tailored to each client. An API gateway takes all API calls from clients, then routes them to the appropriate micro-service with request routing, composition, and protocol translation. Typically it handles a request by invoking multiple micro services and aggregating the results, to determine the best path. It can translate between web protocols and web-unfriendly protocols that are used internally.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|-------|--------------------------------------|
+| API | Application Programming Interface |
+| BSS | Business Support System |
+| bDDN | Big Data Driven Networking |
+| CLI | Command Line Interface |
+| DB | Database |
+| DDI | Domain-Domain Interface |
+| DPI | Deep Packet Inspection |
+| EMS | Element Management System |
+| ETL | Extract-Transform-Load |
+| FS | File System |
+| FTP | File Transfer Protocol |
+| GIS | Geographic Information System |
+| HTTP | Hyper-Text Transfer Protocol |
+| IP | Internet Protocol |
+| IPC | Inter-Process Communication |
+| NFV | Network Function Virtualization |
+| NMS | Network Management System |
+| NoSQL | No SQL or Not only SQL |
+| OAM | Operation Administration Maintenance |
+| OSS | Operation Support System |
+| QoE | Quality of Experience |
+| QoS | Quality of Service |
+| REST | Representational State Transfer |
+| SDN | Software Defined Network |
+
+| | |
+|------|------------------------------------|
+| SNMP | Simple Network Management Protocol |
+| SQL | Structured Query Language |
+| YANG | Yet Another Next Generation |
+
+# 5 Conventions
+
+The keywords "**is required to**" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+
+The keywords "**is recommended to**" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance.
+
+In the body of this Recommendation and its annexes, the words shall, shall not, should, and may sometimes appear, in which case they are to be interpreted, respectively, as is required to, is prohibited from, is recommended, and can optionally. The appearance of such phrases or keywords in an appendix or in material explicitly marked as informative are to be interpreted as having no normative intent.
+
+# 6 General requirements for big data driven networking
+
+## 6.1 General functional requirements
+
+As described in [ITU-T Y.3650], big data driven networking (bDDN) is a type of future network architecture, that provides functions and capabilities based on big data to facilitate network planning, management, operation, control, optimization and security, etc.
+
+The capabilities of bDDN, including capabilities of big data plane, network plane, management plane and interfaces capabilities are described in [ITU-T Y.3650]. In order to support all these capabilities, the general functional requirements of bDDN are described as follows:
+
+- bDDN is required to support big data collection capabilities, the aforementioned big data including structured data, non-structured data and semi-structured data;
+- bDDN is recommended to support big data pre-processing capabilities, the aforementioned big data including structured data, non-structured data and semi-structured data;
+- bDDN is required to have no influence on the performance of the network infrastructure when bDDN system is collecting data from the network;
+- bDDN is recommended to have the capabilities for classifying the big data during the process of data collection;
+- bDDN is required to support big data storage capabilities, the aforementioned big data including structured data, non-structured data and semi-structured data;
+- bDDN is required to support big data analysing capabilities, the aforementioned big data including structured data, non-structured data and semi-structured data;
+- bDDN is required to provide data mining functions and services for their upper layer applications;
+NOTE 1 – 'Upper layer applications' means applications that can make use of functions and capabilities provided by bDDN.
+- bDDN is required to support self-service capabilities for bDDN users;
+NOTE 2 – 'Self-service capabilities' means functions and capabilities to provide service to the network itself.
+- bDDN is required to provide prediction of network behaviour functions;
+- bDDN is required to support service interface capabilities for network planning;
+
+- bDDN is recommended to support softwarization capabilities for network planning;
+ - bDDN is required to support programmability for applications based on bDDN to the network resources;
+ - bDDN is required to support big data driven network management capabilities: operation, administration and maintenance;
+- NOTE 3 – 'Big data driven' means a process or activity which is engaged and improved by big data related technologies. For example, big data driven network management means network management activity which is enabled by big data related technologies.
+- bDDN is required to support big data driven network control and orchestration capabilities;
+ - bDDN is required to support big data driven network planning and optimization capabilities;
+ - bDDN is required to support big data driven network security guaranteeing capabilities;
+ - bDDN is required to provide interfaces between planes, including interfaces between big data plane and network plane, interfaces between big data plane and management plane;
+ - bDDN is required to provide interfaces between layers within the planes of big data driven networking, including interfaces between layers of big data plane, interfaces between layers of network plane;
+ - bDDN is required to support interfaces between related control domains;
+ - bDDN is recommended to support network slicing capabilities for the target network;
+ - bDDN is required to guarantee that activities of big data plane do not worsen the performance for network plane.
+
+### **6.2 General performance requirements**
+
+- bDDN is recommended to collect all data from the network in real time mode.
+- bDDN is required to store various data generated by the network without loss.
+- bDDN is required to store full historical data according to configuration from the bDDN application.
+- bDDN is recommended to analyse data in real time mode.
+- bDDN is required to have process capability matching to real-time data volume when it works in real time mode.
+- bDDN is required to finish analysing data within the time given by a certain bDDN application.
+- bDDN is required to finish analysing data within a time threshold set by bDDN itself when the time is not given by a certain bDDN application. For example, a time threshold is 50s since the data are input to bDDN.
+
+NOTE – Except for special notation, the aforementioned data in clause 6.2 include but are not limited to data generated by deep packet inspection (DPI), logs, alarms, management, data related to network environment and so on.
+
+All data collection should be under permission and authorization of corresponding privacy policy and rules.
+
+# **7 Requirements of big data plane for bDDN**
+
+## **7.1 Requirements of network big data collection for bDDN**
+
+#### **7.1.1 Data source of big data collection**
+
+- bDDN is required to collect the data from several kinds of networks, including mobile networks and fixed networks, and including Internet, enterprise networks, home networks and so on.
+- bDDN is required to collect the data from various network elements, including routers, switches, base stations, mobile terminals, gateways and so on.
+- bDDN is required to collect the data from various management entities, including element management system / network management system (EMS/NMS) entities, business support system / operation support system (BSS/OSS) entities and so on.
+- bDDN is required to collect the data from various bDDN applications, e.g., a kind of traffic analysing software which depends on bDDN.
+
+NOTE – bDDN applications are entities that use functions provided by bDDN. For example, an operation support system, a network management system, etc.
+
+- bDDN is required to collect the various data related to the network, the various data include service data, signal data, and some management related data such as device information, configuration data, routing data, environmental data, etc.
+
+#### **7.1.2 Data scope of big data collection**
+
+It is noted that it is not all the data but rather it is the key data that is to be collected. The key data is useful for analysing and making decisions and can be classified in the following categories:
+
+- Control information related to regular short-term network operations, covering functionalities such as call/session set-up, release and maintenance, security, QoS, idle and connected mode mobility, and radio resource control, etc.
+- Management information covering long-term network operation functionalities, such as fault, configuration, accounting, performance and security management, as well as customer and terminal management. An example of such information is that defined for operation and management, which consists of aggregated statistics on network performance, such as number of active users, active bearers, successful/failed handover events, etc., per base station, as well as information gathered by means of active probing.
+ - bDDN is required to support collection of network management data;
+ - bDDN is required to support network operation support system (OSS) data collecting;
+ - bDDN is required to support network business support system (BSS) data collecting;
+ - bDDN is required to support network system log data collecting;
+ - bDDN system is required to collect the various data related to network users, including basic information of network users, user quality of service (QoS) requirement and user quality of experience (QoE) status, etc.
+
+#### **7.1.3 Type of big data collection**
+
+- bDDN is required to collect multi-type data, which includes structured data, unstructured data and semi-structured data;
+- bDDN is required to support multi-source heterogeneous data collecting;
+- bDDN is required to collect the log data;
+- bDDN is required to collect the configuration data of the network;
+- bDDN is required to collect the alarm/warning data;
+
+- bDDN is required to collect the device state data;
+- bDDN is recommended to collect the environment data of the network;
+- bDDN is recommended to collect some traffic data according to the requirements of the application;
+- bDDN is recommended to collect all the other data about the network device;
+
+NOTE – The other data about the network device are data other than log data, configuration data, alarm/warning data, device state data and environment data. For example, device name, device manufacturer identification, device location, etc.
+
+#### **7.1.4 Methods of big data collection**
+
+- bDDN is required to support multiple methods for big data collection.
+NOTE – For example, bDDN can use deep packet inspection to collect traffic data meanwhile, and bDDN can collect network management data from the network management system (NMS).
+- bDDN is required to support collecting big data scattered in various interfaces of the network using DPI technology.
+- bDDN is required to support gathering records, log files, signal streams from network management devices.
+- bDDN is required to support obtaining external data from external systems or getting it from the Internet.
+- bDDN is required to support network traffic data sensing based on DPI.
+- bDDN is recommended to support the following collection data interfaces: simple network management protocol (SNMP), file transfer protocol (FTP), hyper-text transfer protocol (HTTP), RESTful service and so on.
+- bDDN is recommended to support configuration of collection mode, including active sensing mode and passive sensing mode.
+- bDDN is required to support active sensing (push mode) big data collection methods.
+
+SNMP-based network monitoring is long overdue for an upgrade. It was designed for legacy implementations, with poor scaling for today's high-density platforms, and very limited extensibility. Push mode is an approach for network monitoring in which data is streamed from devices continuously with efficient, incremental updates. Operators can subscribe to the specific data items they need, using yet another next generation (YANG) data models as the common structure and interface.
+
+A push mode continuously streams data out of the network and notifies the client. bDDN enables the push model, which provides near-real-time access to monitoring data.
+
+- bDDN is recommended to support use of YANG models to collect data in push mode.
+- bDDN is required to support passive sensing (pull mode) collection big data methods.
+
+Traditional collection methods use the pull mode when retrieving data from a network device, such as SNMP, command line interface (CLI), and Syslog, used for collecting operational statistics from a network. The pull model is based on a client sending a request to the device, then the device responds to that request. This method has several restrictions due to the growth of objects such as Internet of things (IoT) devices and cloud-based applications.
+
+This model cannot scale for high-density devices, and offers very limited extensibility. On average, network operators use SNMP poll data every five to thirty minutes, but with today's speeds and scale that is not enough to capture important network events. SNMP also uses a push model while sending a trap.
+
+Active sensing is a method where the collection object automatically sends the big data to the big data plane and passive mode is a method where the big data plane acquires the data from the
+
+collection object. The collection objects should be configurable and the collection interval, frequency, data format, etc. should be configurable.
+
+The active sensing method is recommended to support the following features:
+
+In-network customization: The data can be customized in network at run-time to meet to the specific need of applications. This needs the support of a programmable network plane which allows probes to be deployed at flexible locations.
+
+Direct data plane export: The data originated from network plane can be directly exported to the data consumer for efficiency, especially when the data bandwidth is large and the real-time processing is required.
+
+In-band data collection: the active sensing approach allows data to be collected directly for any target flow on its entire forwarding path.
+
+Non-intrusive: the active sensing method should not change the network behaviour or affect the forwarding performance.
+
+### **7.2 Requirements of network big data repository**
+
+#### **7.2.1 Requirements of big data pre-processing**
+
+- bDDN is required to do some data pre-processing according to several pre-set rules, simultaneously when data is collected;
+- bDDN is recommended to support extract-transform-load (ETL) features of big data;
+- It is recommended for the ETL function to be achieved through the distributed computing nodes and to be able to dynamically expand according to the computing load.
+- bDDN is recommended to support data aggregation functions of big data;
+- bDDN is recommended to support data cleaning and transformation functions for heterogeneous structured data;
+- bDDN is recommended to support normalizing the network big data for analysing.
+
+#### **7.2.2 Requirements of big data storage**
+
+- bDDN is required to support the storage of structured data;
+- bDDN is required to support the storage of unstructured data;
+- bDDN is recommended to support for distributed and scalable storage architecture;
+- bDDN is required to support the configurable storage duration according to the requirements.
+- bDDN is required to provide multiple types of database to store big data of different types and origin, the aforementioned databases include but are not be limited to the following:
+ - Relational database;
+ - No SQL or not only SQL (NoSQL) database;
+ - File system;
+ - Distributed file system.
+
+### **7.3 Requirements of network big data analysing**
+
+- bDDN is required to provide big data processing and analysing capabilities;
+- bDDN is required to support multi-source heterogeneous data analysing, the aforementioned data to include but not be limited to the following:
+ - IPv4/IPv6 network data;
+ - Fixed/mobile network data;
+
+- Access/converge/core network data;
+- Text/audio/video data;
+- Traffic/BSS/OSS data;
+- System log data.
+
+#### 7.3.1 big data analysis method
+
+- bDDN is required to support multiple analysis methods, the aforementioned methods to include but not be limited to the following:
+ - Statistical analytical method
+ - Visualization analytical method
+ - Correlation analytical method
+ - Prediction analytical method
+ - Analytical method based on machine learning
+
+#### 7.3.2 big data analysis platform
+
+- bDDN is recommended to support multiple types of big data analysis platforms, the aforementioned platforms to include but not be limited to the following:
+ - Real-time analysis platform
+ - Batch processing
+ - Machine learning
+- bDDN is recommended to use a distributed analytical platform and parallel processing capabilities;
+
+### 7.4 Requirements of network big data service
+
+Concerning network big data service, there are some requirements that are listed as follows:
+
+- bDDN is required to support open softwarization service interface for other entities, the aforementioned interfaces to include but not be limited to the following:
+ - API: application program interface;
+ - IPC: inter-process communication;
+ - RESTful: representational state transfer.
+- bDDN is required to support a visualization service for network planners, operators;
+- bDDN is required to support network big data exchanging service for other entities;
+
+### 7.4.1 Big data visualization
+
+The results from big data mining, analysing and real-time computing are recommended to be illustrated in visual representations, so as to help network operators to gain the meaning of big data directly.
+
+- bDDN is required to support the accessing and importing of structured data, semi-structured data and non-structured data.
+- bDDN is required to support the accessing and importing of data in multi-type databases or multiple data formats.
+- bDDN is required to support the accessing and importing of data through API.
+- bDDN is recommended to support various charts, tables and images, including but not limited to: histogram, curve diagram, scatter diagram, waterfall diagram, Sankey diagram, geographic information system (GIS) map, etc.
+- bDDN is recommended to support the visualization in multiple modes.
+
+NOTE – Examples of visualization modes include web browsers, application terminals, GUI software, etc.
+
+#### **7.4.2 End to end network intelligence**
+
+Based on the big data which is collected and analysed, there are some requirements to support end to end network intelligence through corresponding analysis and prediction models or methods, including network operation, network administration and network maintenance. The aforementioned requirements include the following:
+
+- bDDN is recommended to support the function of the request management, such as the queue of requests, the priority of the request; the authentication of requests;
+- bDDN is recommended to support the functions of access control, security authentication, authorization management;
+- bDDN is recommended to support a service management function; service refers to the capability provided by the big data plane; service management includes the management and configuration of the service interface (e.g., service HTTP, web);
+- bDDN is recommended to support the function of load balancing, and resource scheduling according the service load.
+- Big data plane is recommended to provide various self-services for the network plane and management plane, the services it is recommended to provide include but are not be limited to the following:
+ - The self-optimization service for the network infrastructure layer of the network plane;
+ - The self-optimization service for the network controller of the network plane;
+ - The self-optimization service for the application layer of the network plane;
+ - The self-optimization service for network maintenance of the management plane;
+ - The self-optimization service for network administration of the management plane;
+ - The self-optimization service for network operation and marketing of the management plane.
+
+#### **7.4.3 Network QoS anomaly detection and root cause tracking**
+
+Different applications have different QoS parameter requirements, for example, delay/latency, jitter, round trip time, etc. Network QoS anomaly means a network QoS parameters anomaly. To meet the complex QoS/QoE requirements of different applications/services, the requirements of the bDDN are as follows:
+
+- bDDN is recommended to support automatic monitoring and detecting of the network QoS anomalies.
+- bDDN is recommended to support tracking the root causes of the network QoS anomalies.
+
+#### **7.4.4 Using an API gateway to provide service**
+
+bDDN is recommended to use an API gateway to provide the service for an application. An API gateway is a server that is the single-entry point into the system. The API gateway encapsulates the internal system architecture and provides an API that is tailored to each client. An API gateway takes all API calls from clients, then routes them to the appropriate micro service with request routing, composition, and protocol translation. Typically, it handles a request by invoking multiple micro services and aggregating the results, to determine the best path. It can translate between web protocols and web-unfriendly protocols that are used internally. It might have other responsibilities such as authentication, monitoring, load balancing, caching, request shaping and management, and static response handling.
+
+- bDDN is recommended to use an API gateway to provide the service for application.
+
+- bDDN is recommended to use an API gateway to provide the authentication capability of the service.
+- bDDN is recommended to use an API gateway to provide the monitoring capability of the service.
+- bDDN is recommended to use an API gateway to provide the load balancing capability of the service.
+- bDDN is recommended to use an API gateway to provide the management capability for the service.
+
+# **8 Requirements of network plane for big data driven networking**
+
+## **8.1 Requirements of network application layer**
+
+The network programmability ensures that the network application has the capability to dynamically control and orchestrate the network resource through a network controller. The big data intelligence and service layer provide the network applications with the ability and method to control and orchestrate the network resources.
+
+On the other hand, as the bridge between network plane and management plane, the network application layer implements functions to provide information to the management plane and accept instructions from the management plane.
+
+The requirements of the network application layer of bDDN include the following aspects:
+
+- Network application layer is required to have the capability to get big data intelligence and service from the big data plane to guide the controlling and orchestrating of the network resource.
+NOTE – Big data intelligence in this Recommendation is the capability or functions that a big data plane of bDDN can provide through analysis of the big data.
+- Network application layer is required to have the capability to set up rules or policies for big data plane in order that big data plane can provide big data intelligence and service that are necessary for the network application layer.
+- Network application layer is required to have the capability to control and orchestrate the network resources through the network controller.
+- Network application layer is required to have the capability to provide management information that need not be processed by big data plane to management plane.
+- Network application layer is required to have the capability to accept management instructions from the management plane and transform the instructions to the network control layer.
+
+## **8.2 Requirements of network control layer**
+
+The network controller layer provides the control, orchestration and scheduling of network resources based on requests from the application layer. The requirements of the controller layer of bDDN include the following aspects:
+
+- Network control layer is required to provide a programming interface for the network applications.
+- Network control layer is required to collect resource information from the network infrastructure layer.
+- Network control layer is required to accept instructions from the network application layer and control and schedule network resources based on the instruction.
+
+- Network control layer is required to transform instructions from the network application layer to resource configuration information that can be understood by the network infrastructure layer.
+- Network control layer is required to support dynamic, autonomous control on network resources, including dynamic network resources registration, dynamic network resource scheduling, etc.
+- bDDN system is required to guarantee the data integrity and security when data is transmitted from the network control layer to the network infrastructure layer.
+
+## **8.3 Requirements for network infrastructure layer**
+
+The network infrastructure is where the network elements perform the transporting and the processing functions of data packets according to the decisions made by the network controller. To support big data driven capabilities, the network infrastructure layer of bDDN is required to support the following requirements:
+
+- Network infrastructure layer is required to transport and process data packets according to the decisions made by the network control layer.
+- Network infrastructure layer is required to provide flow control capability when data is exchanged between the network infrastructure layer and the network control layer.
+- Network infrastructure layer is required to guarantee the data integrity and security when data is transmitted from the network infrastructure layer to the network control layer.
+- Network infrastructure layer is required to provide network traffic sensing support based on rules or policies set up by network control layer.
+- Network infrastructure layer is required to provide network programmability capability for the network control layer.
+- bDDN system is required to report resource status to the network control layer.
+- A network infrastructure's main function is user traffic processing and forwarding. While supporting network visibility is important, the network sensing is just an auxiliary function and it should not impede normal traffic processing and forwarding (i.e., the performance is not lowered and the behaviour is not altered due to the telemetry functions).
+- The network operation applications require end-to-end visibility from various sources, which results in a huge volume of data. However, the collection data quantity should not stress the network bandwidth, regardless of the data delivery approach (i.e., through in-band or out-of-band channels).
+- The network infrastructures must provide the data in a timely manner with the minimum possible delay. Long processing, transport, storage, and analysis delay can impact the effectiveness of the control loop and even render the data useless.
+- The network plane telemetry should support incremental deployment and work even though some devices are unaware of the system. This challenge is highly relevant to the standards and legacy networks.
+
+# **9 Requirements of management plane for big data driven networking**
+
+## **9.1 Network marketing operation**
+
+With the evolution of network, faster speed and warmer service brings customers a better experience. Network operators can achieve elaborate and intelligent operation strategies and methods based on big data grasped by network or management systems. bDDN can facilitate network marketing operations for network operators while the following requirements shall or should be supported by bDDN:
+
+- bDDN is required to collect data that are related to QoS/QoE of customers.
+NOTE – For example, some information that can describe delay, real-time bandwidth, customers complaints, etc.
+- bDDN is recommended to establish statistics models to analyse customers' experience for network services by synthetically using the collected QoS/QoE information.
+- bDDN is recommended to predict customers' objectives or requirements, and make personalized operation strategy for customers based on the statistics models.
+- bDDN is required to support analysis for a group of customers that are correlated and make operation strategy for the customers based on analysis.
+- bDDN is required to provide results of analysis and prediction to the upper layer application such as OSS/BSS.
+
+## **9.2 Network planning and engineering**
+
+When mobile customers use the services provided by mobile network operators, there is big data generated both in the user plane and signal plane. By analysing them comprehensively, users' actual experience in their using of services can be known. According to the experience of users within the same base station, the question of whether the base station is poor or not can be judged. Reasonable and intelligent network planning such as increasing the quantity or expanding the capacity of the base station can then be carried out to improve the quality of service for the mobile network efficiently.
+
+Similarly, network planning is also important in a fixed network context.
+
+The following are some requirements related network planning and engineering for bDDN:
+
+- bDDN is required to provide a reasonable and intelligent base station capacity plan for operators using big data plane when bDDN is applied to mobile network.
+- bDDN is required to provide capability of reasonable deployment planning for transport network for operators using big data plane.
+- bDDN is required to provide capability of reasonable deployment planning for access network for operators using big data plane.
+- bDDN is recommended to collect data from user plane and signal plane and store the data for a long period (e.g., three months or longer) when bDDN is applied to mobile network.
+- bDDN is recommended to analyse long-time historical data from user plane and signal plane and store the analysed result for a long period when bDDN is applied to mobile network.
+- bDDN is recommended to have the capability to plan the network based on information including the aforementioned analysed result.
+
+# **10 Interface requirements for big data driven networking**
+
+## **10.1 Requirements for interfaces between layers of big data plane**
+
+Within the big data plane, the interface between the network sensing layer and network big data repository layer is represented by iSD, and the interface between the network analyser layer and data intelligence and service layer is represented by iAI.
+
+The following are some requirements about the interface iSD
+
+- bDDN is required to support at least one of the various protocols that can be used to collect network data, for example, SNMP, FTP, HTTP, etc.
+
+- bDDN is recommended to support various protocols that can be used to collect network data, for example, SNMP, FTP, HTTP, etc.
+- bDDN is required to provide real time data collection function.
+
+The following are some requirements about the interface iAI
+
+- bDDN is required to support one of the various protocols such as HTTP, RESTful or other protocols to provide service from network analyser layer to data intelligence layer.
+- bDDN is recommended to support multiple protocols such as HTTP, RESTful or other protocols to provide service from network analyser layer to data intelligence layer.
+
+## 10.2 Requirements for interface between big data plane and network plane
+
+There is an interface between the network sensing layer (big data plane) and the network infrastructure layer (network plane). The interface is represented by iBN, and Figure 10-1 illustrates this interface, see also Figure 11-1 of [ITU-T Y.3650]. Requirements for the iBN interface are listed as follows:
+
+- Network infrastructure layer is required to have the capability to provide data to network sensing layer through iBN interface.
+- Network infrastructure layer is required to have the capability to guarantee basic functions of network plane not to be influenced by the iBN interface.
+- Network infrastructure layer is recommended to have the capability to classify the data provided through the iBN interface with coarse grain.
+- Network infrastructure layer is recommended to have the capability to negotiate the feature (for example data category, data sending speed and data structure, etc.) of the data provided through the iBN. interface.
+- Network infrastructure layer is recommended to have the capability to accept the classification rules on which the data provided through the iBN interface can be classified with coarse grain.
+- iBM interface is required to support at least one of the management or application layer protocols including SNMP, HTTP, FTP, etc. for iBM interface.
+- iBM interface is recommended to support multiple management or application layer protocols including SNMP, HTTP, FTP, etc. for iBM interface.
+
+
+
+Figure 10-1: Interface between network sensing layer and network infrastructure layer. The diagram shows two main planes: 'Big data plane' on the left and 'Network plane' on the right. The 'Big data plane' contains four stacked components: 'Data intelligence and service', 'Network analyzer', 'Network big data repository', and 'Network sensing'. The 'Network plane' contains three stacked components: 'Network application', 'Network controller', and 'Network infrastructure'. A dashed line labeled 'iBN' connects the 'Network sensing' component of the Big data plane to the 'Network infrastructure' component of the Network plane. Below the Network plane stack, the text 'Y.3652(20)\_F10-1' is present.
+
+**Figure 10-1 – Interface between network sensing layer and network infrastructure layer**
+
+## 10.3 Requirements for interface between big data plane and management plane
+
+There is an interface between the big data plane and the management plane. The interface is represented by iBM, see Figure 11-2 of [ITU-T Y.3650]. Some iBM interface requirements are listed as follows.
+
+- bDDN is required to provide an analysis function of network faults or failure causes through the iBM interface for the management plane.
+- bDDN is required to provide a network optimization analysis function through the iBM interface for the management plane.
+- bDDN is required to provide a precision marketing operation function through the iBM interface for the management plane.
+- bDDN is required to provide active maintenance information through the iBM interface for the management plane.
+- bDDN is required to support collection of a management plane data function through the iBM interface.
+- bDDN is required to support at least one of the management or application layer protocols including SNMP, HTTP, FTP, etc. for the iBM interface.
+- bDDN is recommended to support multiple management or application layer protocols including SNMP, HTTP, FTP, etc. for the iBM interface.
+
+## **10.4 Requirements for interface between domains of big data plane**
+
+There is an interface between the bDDN control domains, it is called the domain-domain interface (DDI), see clause 8 of [ITU-T Y.3650]. The DDI interface should meet the following requirements:
+
+- The DDI interface shall provide reliable transfer of data and signalling messages.
+- Performance of the DDI interface should be matchable to the data carried in the interface.
+- bDDN is recommended to use an out-of-band network to carry the data through the DDI interface.
+- bDDN is recommended to use a special security logical channel (e.g., virtual private network interface) to carry the data through the DDI interface when an out-of-band network is not possible.
+
+# **11 Security considerations**
+
+While implementing requirements related to big data driven networking, security best practices should be adopted such as authentication, authorization and access control and described in [ITU-T Y.2704].
+
+In addition, big data that are used to implement requirements related to big data driven networking should be protected in order to avoid leaking and being destroyed.
+
+In the meantime, operations related to network resources should have multiple reliability guaranteeing measures in order to avoid incorrect operation of network resources and causing the degrading of network performance.
+
+
+
+# SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..dbb297875ee6d8dd712c80d3554db54a2ed4fc31
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cacfe6eeb9fa8ef358c32abeb85f87089709bfe0efc8b10e9bf4c1d1598bb58c
+size 5938
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/2e399449b7f62d40167a65ca88888917_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/2e399449b7f62d40167a65ca88888917_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f1efcb020fb42cb486ae9a5dbe9b5466e5a98855
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/2e399449b7f62d40167a65ca88888917_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ae157f8fb510f51a493e94779734cc41a4b2d6587b1d4894057ee3a55ed1bc12
+size 48013
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..502455917e7fc84ac96ca2ea7c3e4f768e23664f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bfeabb4d25b8b0ae6ebff08e249914a1b5e754f9020271922e0ce9c345d36171
+size 24765
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ee53573128a93030576749440b3044c42b785efc
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/5a4e62bead259c258d069fd3663ea670_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5674e112a9391f9f6fe54338af25496f12408212fc901607a9b7db5829527022
+size 33811
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6749ed7e905c5426799a620ce9ba73b519b596ea
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cd34bb6d9c3fd024be49efca20640256dac81f92f12cd45f90d693c29381741c
+size 20484
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f96a3b41c720a876c8fdb9a1a9cfd114bf05329a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b4dbf4d3f50b6d4ec84418a8c786c9ff1997fdafcf687a70d78125d94560d3d8
+size 43144
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3d422ece1a84aa22757f39f4b562ca7b5134beba
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:aad54790680a712f0ab1bb7f423729e9127956bc2d49882f023cdbb25201ad57
+size 149202
diff --git a/marked/Y/T-REC-Y.3653-202104-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e3354007f73548d165ea6abb82a24ce18ac190fa
--- /dev/null
+++ b/marked/Y/T-REC-Y.3653-202104-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e953baabff4f3c44f5fd27967dcfa81a8b3d07b4a21b0528dbdde9b1afcf7a4c
+size 33425
diff --git a/marked/Y/T-REC-Y.3681-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3681-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3681-202504-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4eabd7df450520f62a5289501c8f70b1c5e57a59
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/124c6108c63173818afb8ed49521e22d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cd37b4ff44552fea1f263a445145be9cbc1e28e24d29ef8bb0bd4ba7924281ca
+size 88281
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..072f073b6d42cbfa77c827c76c611f286177034a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee72ddf991b7b1d543b2694b1687804845ecb97da77cc35e98e4c7dbf5ac163d
+size 4142
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7e3eda4ded106228334ca05757fd69602e35708c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ff59c905ded9406d4ef89db93362df9e34ef7071f052b4edf5b0dd3925d0cafd
+size 38210
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..fe72c4f4db940fda067ec122f386f1a0b0d821aa
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3b5d73a9335426454fb58254f5c2dcb3763e77a9b9cb7e013feb0790044205af
+size 122096
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..67414f12135f9c246a012c520a2f663463075e49
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:da7568898af653e70e69a21ec41dbc0b4aca4e7a00c2a3e8800f9a368c6c4b33
+size 61252
diff --git a/marked/Y/T-REC-Y.3800-201910-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..62cfd2be0ef5e8e8bb256d5b2a5b6dece3646321
--- /dev/null
+++ b/marked/Y/T-REC-Y.3800-201910-I_PDF-E/f4fdd410cdb84df81274da55721e56fb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:583f7ae995634f613599a231dbeba11c1d7d00beb8d83b10053e41779caaa596
+size 53372
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7eb09edfc5dccd5e3df19df2a34a77e5ea1075bd
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/08a978a124d3ed6cf1a3d0cfd89418d0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b81bb1124c519fc7c2af56bd89e55b0fcee6882b653e4a85061c78411da248be
+size 106313
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5adabf40952e2cc1e15dea1b74bba593cff75dae
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/0f985b39edc1d52ba3600c438bc8f0a5_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f67fc6f52a0dafd3d464af7e2857b6b3571e39268f8bfa8589c65f6f620c9b5c
+size 68538
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5b4a817fee1d7bd1ff046d466edb5611d0ff2c21
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:95098562bfd7d045680fd2a649f3f69ddd00a020323aab6fab9fa2105e210d3d
+size 5883
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9b5e833420a6373cacae796da7cbe5baed5802b7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/171115f072e42b379238ed0dd438e9d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:343ddac1b06c414ba4e6d38c7550c135a14920a7901c097078869ef44ac00cec
+size 69245
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5ab1c07f90dbd482297f8378a9067ceeb8085563
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/2b3a967f6ce4f23649be995a353e39f8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9d0d19c40d513a59df62b4471ef14567aff7e107a0575f09da68c6286e391548
+size 104383
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..71b73884f26c388b9c7e83b93d17f7078093b187
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c436a9a89e4d60bcdbe63a93fd0db27c0a35e14e370d942a6907812785b546a8
+size 48379
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..95c95bb6bd97fe1d14ce51f39a189b2cec6cd22a
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/3da1a07cb87051bf616c9876db958cf0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1634f27bdf4dcd822269496a9229eb5526e518717da152974f120b9a0788bc99
+size 35496
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4807b0a05e2a9665986311b8529de777f006d33e
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/4ee27dbf5ef12e7b58b0ef0937bc5a5e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f2314d6a158ed6da723cd9885f0ec1d347a10b2800f59dbb2beb9514f4d05347
+size 65147
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..946dea8a3fdbc5c62bbac756e3c627c38b554071
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5445597cceefaca1ac89e710fe339325_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:392033b06a6da28645f969a30af522354cc10db2acc5c2a33c65d7253d67b86b
+size 36428
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..68732bca97361183e7d5717dff0bb70a1abe3f53
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5a1abd59a95fa47ae192807de151e9eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ed0a4488fe9d4811e820529bb0b7a486d46bc4dafe03241a07e8d872b525ba8a
+size 45692
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1fa62e441ca9a8723fd98837dc220e8b5aabe635
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/5b4e774d63e0e0ed73801a9247755e5f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b3d20da5c4fcc9343b8b07349cfcc83e8ff2641084b7fe7aac2e9b8aa59fd878
+size 250628
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..6c922e5965c91dc8ffb797e6d7eca8ce8ed937b2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/69b7bd65e85cdef6fdd7fb0a8194257c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c1fe45baa6e779c97c48dfe1467a67bf745e22a16b4d6d329a9e7cf468ee1572
+size 77292
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c39a4648a07b12dd441ba1b3a6aeb48a248e54cd
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b187c2b0a55d7af75de829ca747145efa0c5858de7d566d9a150bd3afa52b7cb
+size 77983
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..55934954a2212aee56a2c9d614a94b706356c9e9
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/759c7d62402f0b4651ddce292be5bdef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b4a27841e9fb1c8c176ef9d4a944c54ada703676bbdad5a9690944982625e50e
+size 79863
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a4bcd31917f564bbd735fbfa9e9b424e54231a7f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0962ade5bc8d7ddc51bd8e1aa72f368b5bd11c6c773ffb97001244be84ede34f
+size 42207
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c6140e86bfad1273ed4999ef49499e2abf9ee5e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/76b0cd79baaedd942af4dc42f2e764b8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:7986f0cb750dd838fc263f8b8c58a0dbfd3a7a79b16a46dbb30933475dfe2b67
+size 96826
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..26f2363bf08b2fed0c838ecd42904a550c14d4ac
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/812e188283162af0b54fb3e30ffee51b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9841a177a83685367be99aba7302d14128e32672113af5d8327b53c76bb2ca77
+size 51034
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..389f78795979babd4442c954667fdf8750cfd355
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/aaf3e6e44cdeabd6d1df869c5f392ea1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:719c8680d742925ffb62562a7c4e9272491497a43055fff58d0d8bc0a5fe5d7c
+size 65265
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..89cc35481a1ebfd9d71024ef329ba39aeac85080
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/c85ded401105f62f2d6ff26b3b5eb4af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f73724fb7b27df2f33ae0feebff7204f2b65e376be19bddd52b24177e1f8e063
+size 52318
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9b8cc946d9e04bade87af727e95b7a2a0c13156d
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:250adb5057196b44a339ecfea1bf9792728a4c2808635057ea3b881d3a1dcac5
+size 113078
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/dcb5711d118ae6753b0e12f86eda37db_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/dcb5711d118ae6753b0e12f86eda37db_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3b5857b664669cfd17db5e97f0c94d421f44ae18
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/dcb5711d118ae6753b0e12f86eda37db_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:54926c3afc3e9d6dec652d2a16951fea173967b52f4ebbfb0f760046698b9a29
+size 78370
diff --git a/marked/Y/T-REC-Y.3805-202112-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..da1c433f3c7d2bd804e31f4638d948a969912bdf
--- /dev/null
+++ b/marked/Y/T-REC-Y.3805-202112-I_PDF-E/e354b57563dae469c00b412b2abdf765_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c1e954a4bb56c9d6289936f2eafd143e075cf3099e95cf2f982f452e81861810
+size 48292
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..edc84922a38bb36e312b6e8c70b0fbabc5d6f18b
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/367926125450c2bc3f4bdca9d59a62ba_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c1be786c3615c3455ffb148855796c3fb15b32f4d5d5eb14e0567b97c1ab99fa
+size 44928
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..645b5ff237dd9ea92a0c0b9ffabcde90a06c9b35
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/7f17c430b9598e4d748a8041457810b3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:27ff4d15f527b42ff4dff43c689f55c1bb6d02a4d1ff9ce2e5d8cb20523ca915
+size 28037
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5b5a17ec5f20a6a46b48fd338f7202fe8a67afa7
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1c6343ef8c98a28abfa8dfa946e81b809415c878c2088b81db19900e211943b8
+size 85537
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..212cb95fa6b7181de9d146f11a712190095e5e01
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:72527e5c09df77cea3ecedf0e1bc4cfcc73dbf5a65f64157e675c3a348137e57
+size 46499
diff --git a/marked/Y/T-REC-Y.3826-202409-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3cb5d1130844f9cd14baa0b624090dcc5da5738c
--- /dev/null
+++ b/marked/Y/T-REC-Y.3826-202409-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:49c394e92e064fe351efa49e8040d12700c4a5ff2d6068f0afdb868caf3ff9d3
+size 47458
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/43837b056625d3d6ce615e4c02f163bb_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/43837b056625d3d6ce615e4c02f163bb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..37143bc134c931a70652ea49e3005fb1d72eb3ed
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/43837b056625d3d6ce615e4c02f163bb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cbf294c40dee64d29a10bb2d4aa78906aa68246bfad5d43e23c7fe30978ffac2
+size 80192
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/51db757d054ce1ce83c436a3578b56ca_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/51db757d054ce1ce83c436a3578b56ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8fbad0e1ef9cb813320a4d4d5767bb83c1aa6db2
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/51db757d054ce1ce83c436a3578b56ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4a06c0fc08937727a5c129345071bcf573a6071c504c5b0721352fcdc2756a19
+size 61851
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..714c7b0b1f910949e40fd6f86209d4fec91e0926
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/7efae06af3af43ffe5d4b956a679cf54_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9a5a199358c89560652aa2144c555c88082f2d03915bf9b7b3634b3a6626f12a
+size 138921
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..01094e5852b239d964edd98a848b4013059059ee
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/a33da0f14e456f92539ce3e9b7d81f9a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:371df17557c834438fa91faf555bc193156051ab221b7ace735814c29fb6aced
+size 122053
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8cbb4a1fb87c1ae1ad2f9242246311fb973f93ba
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/adb1f42239329fa8283d1a40005f989f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d60e0b2089e875889108cba4ea639cdf9be1c4fc06dfa66cf761af005077ec8e
+size 60558
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..58d173861b19ba237f04d3c1d1c97489fc50496f
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d69aae1bae29747df1c933adc525ec8feeaada5a3774d5e449746c74b3948921
+size 115327
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c30c3511c3a6c091d06b704123093dfb4a90f258
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:019ec43bf5fc2b472be3c830f8d86846bb1b0a721a73d05e62b978f5a47a1369
+size 129245
diff --git a/marked/Y/T-REC-Y.3832-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..22771829da7b0d631c27fee66b50cba9e490bef1
--- /dev/null
+++ b/marked/Y/T-REC-Y.3832-202512-I_PDF-E/eefe19c5e14dc4d6c316b7f7fbb7d7d7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3b796d8738561506e3abe2789bbf43f76c357f5ba483009dc739fb65797ba183
+size 112042
diff --git a/marked/Y/T-REC-Y.4201-201802-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.4201-201802-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a357cc5c81edd680afde86927d2cf9e814f195a7
--- /dev/null
+++ b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4357c205df222c914eb40c163aa1443380e560cba622bed7ff2c9927295a247c
+size 74254
diff --git a/marked/Y/T-REC-Y.4201-201802-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d2122ba036000b0200bc7491f236de4d009c04c5
--- /dev/null
+++ b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1549f90285a5f27cfac30b1afa1953a9eaf93a42f044897bfa2633d9b7802b31
+size 145400
diff --git a/marked/Y/T-REC-Y.4201-201802-I_PDF-E/raw.md b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..1d6f1515a5fdbc1b4b029755701537f426fe18b9
--- /dev/null
+++ b/marked/Y/T-REC-Y.4201-201802-I_PDF-E/raw.md
@@ -0,0 +1,660 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.4201
+
+(02/2018)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Internet of things and smart cities and communities –
+Requirements and use cases
+
+# --- **High-level requirements and reference framework of smart city platforms**
+
+Recommendation ITU-T Y.4201
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+| | |
+|-----------------|---------------|
+| CLOUD COMPUTING | Y.3000–Y.3499 |
+| Y.3500–Y.3999 | |
+
+## INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|----------------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.4201
+
+# High-level requirements and reference framework of smart city platforms
+
+## Summary
+
+Recommendation ITU-T Y.4201 presents the high-level requirements and reference framework of smart city platforms (SCPs).
+
+The SCP is a fundamental platform supporting all the services and applications of a smart city, with the objective to improve quality of life, provide urban operation and services for the benefit of citizens while ensuring city sustainability.
+
+These high-level requirements include comprehensive and updated repositories of city information, infrastructure life-cycle management, inter-system communication, security support, maintenance support, processor controls, decision-making support, real-time dissemination of public information, resilience and interoperability.
+
+This Recommendation benefits the plan, design, construction, deployment, operation and maintenance of smart cities and communities.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.4201 | 2018-02-06 | 20 | 11.1002/1000/13388 |
+
+## Keywords
+
+Cities, information and communication technologies (ICTs), Internet of things (IoT), smart cities and communities (SCCs), smart city platform (SCP).
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+### NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2018
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|---|--------------------------------------------------------------------|------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 1 |
+| | 3.1 Terms defined elsewhere..... | 1 |
+| | 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 | Abbreviations and acronyms ..... | 2 |
+| 5 | Conventions ..... | 3 |
+| 6 | Overview of smart city platforms ..... | 3 |
+| | 6.1 SCP functionalities ..... | 4 |
+| | 6.2 General principles of building SCPs ..... | 5 |
+| 7 | High-level requirements of SCPs ..... | 5 |
+| | 7.1 Comprehensive and updated repository of city information ..... | 5 |
+| | 7.2 Infrastructure life-cycle management..... | 5 |
+| | 7.3 Inter-system communications..... | 6 |
+| | 7.4 Security support..... | 6 |
+| | 7.5 Maintenance support ..... | 6 |
+| | 7.6 Showcase support ..... | 7 |
+| | 7.7 Controls of processes..... | 7 |
+| | 7.8 Support for decision making ..... | 7 |
+| | 7.9 Real time dissemination of public information ..... | 7 |
+| | 7.10 Resiliency ..... | 8 |
+| | 7.11 Interoperability ..... | 8 |
+| 8 | Reference framework of SCP ..... | 8 |
+| | 8.1 Architecture of SCPs ..... | 8 |
+| | 8.2 Acquisition/interconnection functions..... | 10 |
+| | 8.3 Data/knowledge functions ..... | 10 |
+| | 8.4 Interfacing functions..... | 11 |
+| | 8.5 Services support functions..... | 11 |
+| | 8.6 Security and management functions..... | 11 |
+| | Bibliography..... | 12 |
+
+
+
+# Recommendation ITU-T Y.4201
+
+# High-level requirements and reference framework of smart city platforms
+
+## 1 Scope
+
+This Recommendation defines the reference framework and high-level requirements of smart city platforms.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- [ITU-T Y.3600] Recommendation ITU-T Y.3600 (2015), *Big data – Cloud computing based requirements and capabilities*.
+- [ITU-T Y.4200] Recommendation ITU-T Y.4200 (2018), *Requirements for the interoperability of smart city platforms*.
+- [ITU-T Y.4900] Recommendation ITU-T Y.4900/L.1600 (2016), *Overview of key performance indicators in smart sustainable cities*.
+- [ITU-T Y.4903] Recommendation ITU-T Y.4903/L.1603 (2016), *Key performance indicators for smart sustainable cities to assess the achievement of sustainable development goals*.
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 big data** [ITU-T Y.3600]: A paradigm for enabling the collection, storage, management, analysis and visualization, potentially under real-time constraints, of extensive datasets with heterogeneous characteristics.
+
+NOTE – Examples of dataset characteristics include high-volume, high-velocity, high-variety, etc.
+
+**3.1.2 city** [ITU-T Y.4900]: An urban geographical area with one (or several) local government and planning authorities.
+
+**3.1.3 open standards** [b-OpenStandards]: Standards made available to the general public and are developed (or approved) and maintained via a collaborative and consensus driven process.
+
+NOTE – Open Standards facilitate interoperability and data exchange among different products or services and are intended for widespread adoption.
+
+**3.1.4 smart sustainable city (SSC)** [ITU-T Y.4900]: A smart sustainable city is an innovative city that uses Information and Communication Technologies (ICTs) and other means to improve quality of life, efficiency of urban operation and services, and competitiveness, while ensuring that it meets the needs of present and future generations with respect to economic, social, environmental and cultural aspects.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 city platform:** A computer system or integration of computer systems that uses information and communication technologies (ICTs) to access data sources and process them to offer urban operation and services to the city.
+
+NOTE – The concept is extended to a community.
+
+**3.2.2 corrective maintenance:** Maintenance performed after a problem occurs.
+
+NOTE – The SCP is recommended to manage notifications or warnings and ensure technical possibilities to send messages, e-mails, SMS and make telephone calls related to these notifications and warnings.
+
+**3.2.3 open interface:** A public standard for connecting hardware to hardware and software to software. Open interfaces are designed and documented for safe and easy use by third party developers and freely available to all.
+
+**3.2.4 preventive maintenance:** Maintenance performed on an SCP regularly while it is still in operational order to reduce failure.
+
+NOTE – The SCP is recommended to store and assess the relevant indicators for maintenance management. The maintenance plans should be based on these indicators.
+
+**3.2.5 smart city platform (SCP):** A city platform that offers direct integration of city platforms and systems, or through open interfaces between city platforms and third parties, in order to offer urban operation and services supporting the functioning of city services, as well as efficiency, performance, security and scalability.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|-------------------------------------------|
+| API | Application Programming Interface |
+| CEP | Complex Event Processing |
+| ETL | Extract, Transform, Load |
+| GIS | Geographic Information System |
+| ICT | Information and Communication Technology |
+| IoT | Internet of Things |
+| IT | Information Technology |
+| JMX | Java Management extensions |
+| M2M | Machine-to-Machine |
+| OAM | Operation, Administration and Maintenance |
+| REST | Representational State Transfer |
+| RPO | Recovery Point Objective |
+| RTO | Recovery Time Objective |
+| SCC | Smart Cities and Communities |
+| SDK | Software Development Kit |
+| SLA | Service Level Agreement |
+| SNMP | Simple Network Management Protocol |
+| SSC | Smart Sustainable City |
+
+## 5 Conventions
+
+In this Recommendation:
+
+The expression "is required" indicates a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The expression "is recommended" indicates a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance with this Recommendation.
+
+The expression "can optionally" and "may" indicates an optional requirement which is permissible, without implying any sense of being recommended. This term is not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with this Recommendation.
+
+## 6 Overview of smart city platforms
+
+An SCP is designed to provide means for enabling new smart city applications to be rapidly created, deployed, extended and managed. It is recommended to provide tools and services for aggregation and backhauling of data communication, city cloud architectures, IoT service creation, security and threat intelligence, device and connectivity management platforms, data collection, analytics, while also addressing customer experience.
+
+An SCP directly integrates city platforms and systems (i.e., SCP functions), or through open interfaces between the SCP and external providers, to offer urban operation and services supporting the functioning of city services, as well as efficiency, performance, security and scalability. As illustrated in Figure 1, an SCP has the following SCP functions:
+
+- services support functions,
+- interfacing functions,
+- data/knowledge functions,
+- acquisition/interconnection functions, and
+- security and management functions.
+
+The external providers include:
+
+- services and applications providers,
+- data and computation providers, and
+- sensing and infrastructure providers.
+
+There are interfaces for communication between the SCP with the external systems or other platforms. These interfaces are shown in Figure 1 as red arrows and are detailed in the following list:
+
+- The services interface connects an SCP's services support functions and the external data and computation providers.
+- The interoperability interface connects an SCP's data/knowledge functions interoperability and the external database and computation systems.
+- The acquisition interface connects an SCP's acquisition/interconnection functions and the external sensing and infrastructure systems.
+
+All the above interfaces are required to implement open standards.
+
+
+
+The diagram illustrates the architecture of a Smart City Platform (SCP) and its interactions with external systems. The SCP is a central component with a grey border, containing five main functional blocks: 'Security and management functions' (a vertical block on the left), and four stacked horizontal blocks on the right: 'Services support functions', 'Interfacing functions', 'Data/knowledge functions', and 'Acquisition/interconnection functions'. The SCP is connected to three external provider blocks, all represented by green dashed rectangles. At the top is 'Service and application providers', connected to the SCP via a red double-headed arrow labeled 'Services interface'. At the bottom is 'Sensing and infrastructure providers', connected to the SCP via a red double-headed arrow labeled 'Acquisition interface'. To the right is 'Data and computation providers', connected to the SCP via a red double-headed arrow labeled 'Interoperability interface'. A small identifier 'Y.4201(18)\_F01' is located at the bottom right of the diagram.
+
+Figure 1 – Overview of an SCP and external systems/platforms. The diagram shows a central SCP block with four internal modules: Security and management functions, Services support functions, Interfacing functions, Data/knowledge functions, and Acquisition/interconnection functions. The SCP is connected to Service and application providers (top), Sensing and infrastructure providers (bottom), and Data and computation providers (right) via Services interface, Acquisition interface, and Interoperability interface respectively.
+
+**Figure 1 – Overview of an SCP and external systems/platforms**
+
+### 6.1 SCP functionalities
+
+The SCP is required to enable the integration of existing and future city applications and services.
+
+The SCP is required to allow city managers to:
+
+- a) manage the city's infrastructure including remote provisioning, configuration, firmware updates and device troubleshooting;
+- b) make decisions based on the data received and processed;
+- c) coordinate services (e.g., emergency services);
+- d) control service quality;
+- e) showcase the status of the city's infrastructure and services;
+- f) log city events;
+- g) distribute relevant data and information to citizens;
+- h) support the reuse of applications, devices and network infrastructure;
+- i) connect the city platform with different vertical systems;
+- j) interconnect the city platform with other city platforms;
+- k) provide reference points to connect the city platform with external third-party services;
+- l) protect smart city assets and prevent infections via security analytics and threat intelligence.
+
+The SCP may enable scenario simulations, forecasting and planning.
+
+### **6.2 General principles of building SCPs**
+
+The following general principles of building SCPs are required to be met.
+
+- a) Horizontality: support capabilities in different fields of application, enabling the simultaneous deployment of multiple services on the same infrastructure.
+- b) Interoperability: capability of supporting different technologies for capturing information, and open standards, as well as interconnecting with internal/corporate and/or external information systems. This feature is described in detail in [ITU-T Y.4200].
+- c) Performance: ability to handle a large number of devices, services and processes efficiently.
+- d) Scalability: ability to increase processing, interconnecting and storage capacities without needing to change the architecture.
+- e) Robustness and resilience: capability to continue to function when faced with problems.
+- f) Security: guarantee of data preservation and reliability.
+- g) Modularity: ability to be easily broken down into parts.
+- h) Flexibility: applicability to various smart city services.
+- i) Extensibility: growth capability to meet new needs.
+- j) Semantics: ability to develop the data structures containing the meaning of concepts, properties, and relationships that formally represent city entities, events and scenes.
+- k) Based on open standards: simplifying the integration with other platforms and developing applications on the platform that may be reused and portable among different platforms.
+- l) Operable and manageable: provide tools for installing, operating, managing and maintaining the platform.
+
+## **7 High-level requirements of SCPs**
+
+### **7.1 Comprehensive and updated repository of city information**
+
+The SCP is required to handle a comprehensive and updated repository of city information through the following functions:
+
+- a) hosting a freely accessible catalogue of standardized data on the city;
+- c) enabling cross-city overviews using this data;
+- d) facilitating the integration of data with varying levels of latency;
+- e) providing open and standardized interfaces for external providers to access this data;
+- f) enabling security and integrity of data, as well as security of users.
+
+### **7.2 Infrastructure life-cycle management**
+
+The SCP is required to coordinate the management of the infrastructure, considering secure and multi-user monitoring and operation of different city resources, elements or systems. The SCP is required to orchestrate the sensing and infrastructure providers, for instance, public transportation systems, energy production, waste collection, off-street and on-street parking management, etc. via the acquisition interface (see Figure 1). The external management of infrastructure includes:
+
+- a) access to data from sensors, databases and information from other applications;
+- b) the operation of city sensors using standardized solutions;
+- c) registration of different activities carried out on city resources, elements or systems;
+- d) management of maintenance of equipment and infrastructure;
+- e) support monitoring tools such as Java management extensions (JMX) or monitoring protocols such as the simple network management protocol (SNMP).
+
+### **7.3 Inter-system communications**
+
+The SCP is required to allow inter-system communications through the following functions:
+
+- a) use open and secure application programming interfaces (APIs) and standard protocols to communicate between applications and with other management systems;
+- b) conditional and secure access to emergency services.
+
+### **7.4 Security support**
+
+#### **7.4.1 General aspects**
+
+The SCP is required to include appropriate measures to maximize privacy and security of citizens by implementing tools in order to:
+
+- a) Back up critical information.
+- b) Guarantee non-repudiation in network security.
+- c) Support anonymised data.
+- d) Guarantee security and integrity of data.
+- e) Support authentication and authorisation.
+- f) Control access to the platform and to all the elements accessed through it.
+- g) Support confidential communications.
+- h) Ensure confidential access to data, ensuring that each agent only has access rights to the data assigned to it.
+- i) Define and manage security policies.
+- j) Maintain repositories of existing users registered by local authorities.
+
+#### **7.4.2 Profiling**
+
+The SCP is recommended to ensure the privacy or security of the data stored or managed by the city, particularly in environments with shared resources. Furthermore, different access profiles can access different types of groups of data, thereby avoiding their misuse.
+
+The SCP is recommended to guarantee the secure exchange of data along the platform from the physical devices to applications.
+
+The SCP is recommended to allow for the definition of different profiles (such as administrator, external providers, citizens) with appropriate access rights, authorising or denying access to the different applications and defining the required privileges for operating with identified sets of data.
+
+Management of roles/permissions is recommended to be established at least for three security levels:
+
+- a) Data access: limiting the information that can be viewed by each user. For example, a user of a specific service only has access to information corresponding to its service.
+- b) Access to the elements of the platform: limit access to reports and dashboards configured in the platform. For example, a user of a service is only able to access reports defined by the data corresponding to their role.
+- c) Functions: limited actions available to a certain user according to their profile. For example, a user of a report may determine which reports or objects final users have access to.
+
+### **7.5 Maintenance support**
+
+The SCP is required to include appropriate measures for its adequate maintenance.
+
+The SCP is recommended to support preventive maintenance and corrective maintenance.
+
+### 7.6 Showcase support
+
+The SCP is required to include the functionality of showcasing the status of its infrastructure and services. The presence of information includes:
+
+#### a) **Status of city infrastructure:**
+
+- engineering infrastructures, such as energy supply, water supply and drainage, transportation, logistics, communication, environment and disaster prevention;
+- social infrastructure, such as administration, welfare, health, education, science, culture, sports, and entertainment.
+
+#### b) **Information of services [ITU-T Y.4903]:**
+
+- economy aspects, such as employment, trade, productivity and innovation;
+- environmental aspects, such as air quality, water and sanitation, noise, soil and biodiversity;
+- societal and cultural aspects, such as education, health, safety, housing and culture.
+
+### 7.7 Controls of processes
+
+It is recommended that the SCP supports controlling the following internal and/or external processes:
+
+- consumption analysis, warnings and trends, etc.;
+- cost allocation;
+- sustainability (efficient use of facilities, greenhouse gas emissions, etc.) and reliability of infrastructures;
+- optimization of processes and planning;
+- crisis dashboard.
+
+The SCP is also recommended to support the generation of operating reports.
+
+### 7.8 Support for decision making
+
+The SCP is recommended to support decision-making processes to improve city resilience by providing:
+
+- simulations based on current and past information;
+- assessment and deployment of action plans in complex scenarios;
+- predictive modelled analysis of the city;
+- data mining and statistical analysis;
+- integration with business intelligence systems and tools.
+
+### 7.9 Real time dissemination of public information
+
+The SCP is required to enable transmission of open, reliable and quality information, on a constant basis and free from interruptions, in standardized formats to be accessible from multiple ICT devices.
+
+This information is applicable to the following scenarios:
+
+- end-user citizen services (the information society);
+- external services and applications;
+- other administrative public services;
+- services for purposes of accountability (transparency).
+
+### 7.10 Resiliency
+
+The SCP is recommended to:
+
+- Ensure the ongoing operation of services according to established service level agreements (SLAs). These services may require availability 24X7 and a service level of over 99.9% annually. Providers may offer solutions complying with these requirements.
+- Guarantee disaster recovery with limited recovery time objectives (RTOs) and recovery point objectives (RPOs).
+
+### 7.11 Interoperability
+
+The SCP is required to comply with [ITU-T Y.4200].
+
+## 8 Reference framework of SCP
+
+### 8.1 Architecture of SCPs
+
+The architecture of an SCP (shown in Figure 1) can be described in detail (shown in Figure 2). Each function offers capabilities; these are detailed below:
+
+- Acquisition/interconnection functions: offer mechanisms for capturing data from the collection systems (see clause 8.2). They also enable interconnection with other external providers that only use data. These functions provide other capabilities such as:
+ - Abstract: This allows for the gathering and refining of data from devices for desired processing in an agnostic manner.
+ - Tagging: This allows for the received information to be transformed to the data structures defined in the platform. It allows for the source of the data received to be identified by adding tags including identifier and registration information.
+- Data/knowledge functions: support the processing of data (see clause 8.3). They receive data from both the acquisition/interconnection functions and the interfacing functions and include functionalities which enable the movement of large amounts of data, and data processing and analysis functionalities to generate new datasets or modify/complete existing ones. Other functionalities offered are:
+ - Data management: This provides a systematic way to create, retrieve, update and manage data.
+ - Data analysis: This provides the capacity to analyse the data.
+ - Big data: This provides the capacity to store and work with large amounts of data.
+ - Geographic information system (GIS): This provides the capacity to work with geospatial information.
+ - Real-time repository: This provides the capacity to work with information in real time.
+- Interfacing functions: provision of services for smart cities (see clause 8.4). They also offer open and standardized interfaces for the data/knowledge functions and the services support functions, which are compliant with the security policies. Other functionalities that are provided are:
+ - APIs that allow access to the service provided by the SCP.
+ - Open data portal that allows data to be made publicly available.
+- Services support functions: These support various services connected through interfacing functions and the APIs supplied (see clause 8.5). Applications can be running on the platform or can be other external services that publish or use the information. Some services support functions that may be offered are:
+
+- e-Government support: These services are enabled to match electronic public administration and other government needs.
+ - Transportation support: These services manage transport information and allow the traffic of the city to be managed.
+- Security and management functions: These functions provide horizontal support to the other functions by offering services such as audits, monitoring and security (see clause 8.6). Some of the functions that may be offered are:
+- Security: This provides security mechanisms such as authentication, authorization, ciphering, etc.
+ - Monitoring: This collects platform operation information.
+ - Audit: This registers who has accessed sensitive information.
+ - Logging: This traces the execution of the applications and/or the systems of the platform.
+ - Configuration: This allows access to the configuration of the systems and to change the execution parameters.
+ - Operation, administration and maintenance (OAM): Processes and tools that allow the platform to be operated, managed and maintained.
+
+
+
+**Service and application providers**
+
+e-Government, Healthcare, Transportation, Tourism, Logistics, Environment, ..., Energy
+
+**Services interface**
+
+**SCP**
+
+**Security and management functions**
+
+Security, Monitoring, Audit, Logging, OAM, Configuration
+
+**Services support functions**
+
+e-Government support, ..., Transportation support
+
+**Interfacing functions**
+
+APIs, Open data portal
+
+**Data/knowledge functions**
+
+Data management, Data analysis, Real-time repository, Big data, GIS
+
+**Acquisition/interconnection functions**
+
+Abstract, Tagging
+
+**Interoperability interface**
+
+**Data and computation providers**
+
+Database and computation systems
+
+**Acquisition interface**
+
+**Sensing and infrastructure providers**
+
+Sensing and data collection system: sensors, RFID, video
+
+City infrastructure: water, gas, electricity, traffic, buildings
+
+Y.4201(18)\_F02
+
+Figure 2 – Reference framework of an SCP. The diagram illustrates the architecture of a Smart City Platform (SCP) and its interactions with external providers. At the top, 'Service and application providers' (e-Government, Healthcare, Transportation, Tourism, Logistics, Environment, ..., Energy) connect to the SCP via a 'Services interface'. The SCP itself is divided into 'Security and management functions' (Security, Monitoring, Audit, Logging, OAM, Configuration) and 'Services support functions' (e-Government support, ..., Transportation support, Interfacing functions with APIs and Open data portal, Data/knowledge functions with Data management, Data analysis, Real-time repository, Big data, and GIS, and Acquisition/interconnection functions with Abstract and Tagging). The SCP interacts with 'Data and computation providers' (Database and computation systems) via an 'Interoperability interface'. At the bottom, 'Sensing and infrastructure providers' (Sensing and data collection system: sensors, RFID, video; City infrastructure: water, gas, electricity, traffic, buildings) connect to the SCP via an 'Acquisition interface'.
+
+Figure 2 – Reference framework of an SCP
+
+### 8.2 Acquisition/interconnection functions
+
+It is required that the acquisition/interconnection functions:
+
+- a) Integrate information from the different sources of data (collection systems) as defined in [ITU-T Y.4200] that may include:
+ - sensors, actuators, gateways and devices such as traffic lights, buildings, weather stations;
+ - personal mobile devices, vehicles or digital home devices;
+ - social networks;
+ - other information technology (IT) systems, such as SCADAs or vertical domain management solutions, which may be proprietary solutions.
+- b) Supply information to the data/knowledge functions independently from the devices, and formatting the acquired data according to semantic processing.
+- c) The acquisition/interconnection functions are independent of network information and control.
+
+The acquisition/interconnection functions are required to support:
+
+- independent end-to-end services for accessing devices;
+- interfaces, APIs and open standard protocols;
+- security and monitoring;
+- discovery and access to IoT/machine-to-machine (M2M) applications;
+- identification and naming of devices and applications; and
+- management aspects (including remote management of entities).
+
+### 8.3 Data/knowledge functions
+
+The data/knowledge functions contain elements for processing, managing and using information.
+
+It is required that the data/knowledge functions handle:
+
+- a) integration of information from the external systems and computation systems as defined in [ITU-T Y.4200];
+- b) access to all information (both past records and real-time information);
+- c) movement of data received from the acquisition/interconnection functions, between the different functions of the knowledge functions for storage, processing and recovery, and towards the interfacing functions. Data in these functions has already been extracted from the source devices and is recommended to be processed following standard data models;
+- d) support for real-time processing of data received from the acquisition/interconnection functions through modules with complex event processing (CEP) engines, rule engines;
+- e) batch handling support for data received from extract, transform, load (ETL) and machine learning;
+- f) support for analytical processing of data using business intelligence processes, etc;
+- g) support for GIS processing of data to enable geolocation, carrying out geographical queries;
+- h) security in data access, to control which user/role/profile is accessing which data.
+
+The data/knowledge functions are recommended to include components to enable the semantic processing of data, including data management and data analysis.
+
+### **8.4 Interfacing functions**
+
+The interfacing functions facilitate the provision of services for smart cities by offering interfaces and functions, such as the development kit and web portal that will be used to implement the services rendered to clients, such as:
+
+- interconnection between applications and platforms;
+- access to the platform by external services;
+- publishing of an open data portal that can be used from the services support functions;
+- building services inside the service support functions using the development kit that includes software development kits (SDKs);
+- secure access to the APIs, the development kit, web portal, etc.
+
+Portability between platforms and cities is recommended to be guaranteed based on a set of standard APIs in the interfacing functions, thereby creating a real ecosystem of applications with a critical mass that lowers the access barrier to developers of applications.
+
+The APIs are required to follow the overall API representational state transfer (REST) trend.
+
+The APIs are recommended to support different data access modes, including push (subscription and notification) and pull (request and response). They are also recommended to support geo-referenced queries.
+
+The API data access model may not distinguish between the specific data models, but in order to ensure interoperability, it is recommended to use a means of transport that is compatible with the existing data model.
+
+### **8.5 Services support functions**
+
+The services support functions provide support to municipal services and business and value added applications by:
+
+- a) support of the external services and applications as defined in [ITU-T Y.4200];
+- b) command centres deployed depending on user's profiles and permissions;
+- c) integrated maintenance contract management application, including SLAs based on real data.
+
+These services and applications, such as e-government, healthcare, transportation, tourism, logistics, environment and energy management, can be developed by external providers. Therefore, it is required that this function enables the deployment of these services in the SCP. Services developed by external providers can access all information and the services offered by the platform through interfacing functions.
+
+### **8.6 Security and management functions**
+
+These functions provide horizontal support to the other functions by offering services such as security, monitoring, audits, logging, OAM, configuration, etc., including:
+
+- a) configuration of a platform repository to allow storage of all configuration information;
+- b) online configuration management enabling overall management using an online application including API REST management interfaces;
+- c) security repository connectors enabling platform security to be delegated to the city's user management solution.
+
+## Bibliography
+
+[b-OpenStandards] *Definition of Open Standards*, .
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..b251589cf40ace6dacc78699abda475ccc29cb4a
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f5a5181407216d035f79590e56aec9a16d90fff38afd14731b2addf225d041a7
+size 4098
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/3267a096e9ca525744d8cd820f12eb59_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/3267a096e9ca525744d8cd820f12eb59_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d5540276158d466465bb2fc674a38f30e104d144
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/3267a096e9ca525744d8cd820f12eb59_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:62b8f90986ac7fe5b9984923b492ad3b3d36ee1e502c09d70c5d3753273d561b
+size 43302
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..12241a938336537e3e6ef0dde3648f40440e85cd
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/33ed1f9b27c7c21c797aa928b0f06851_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:314d0ed8b7cd03f3e03ea046a0680be9b2701f1ee516556b993334043aa53a03
+size 28787
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f1e22749d387ee51ce92ce3206ecf3b817a2417f
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4237bdb8e77b4f613f02dcdee73d3e91ed9a1dd0b79577d4c289a68d00529503
+size 32992
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..85331fd5973729dfc42e4393e185bc10a6dea01e
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/63c666b05041841b01fdef9fa4153ff7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:88d60c9d31ecbd8ec781d3d9bf91bf474054581b525c7764c2f022ab004a8a41
+size 46130
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/77464a47f104d0d647b2414591137b64_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/77464a47f104d0d647b2414591137b64_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f3219b569a1acd4cc9e724aec28bc11f418b39c0
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/77464a47f104d0d647b2414591137b64_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:8fb9df41c9cced149a4dada269afdfd73e081eea590efd2749bc1256b0cc4343
+size 49880
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d0f5ce0a22cbe22ffade9787aafbed8ee7b9a5ad
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/793eb94053441c45bcf1e1fad773a7eb_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:22101014c533b934efca87b99b8d9491698fe80f97ad2c64750ccafd5faf9eba
+size 29266
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cd99cc62ff4b3a9ca3e18dbcf1713ea6d2f8164c
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/898fb89a50d9ec1dfb4e425c816976a7_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fa57546d674d07009309fb123c169cc9cb03df3d54f6cc9093b20dd2b99783b7
+size 42975
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..941edf2eb493a03e844544a988224e27881194a5
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/8fbdfc3d17fb1dae7b2d8f5a287fa9fc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:85220f29ca7c823ff05eefffcc4f3757e4eb04fdd43601e1617a0c88e67e08ec
+size 30501
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..33273224a31eee181bbe02f600105dd97952a84b
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a08e28a48a147522dbf767443db02deda6279af1fbcf391bf22db2e3fb08b307
+size 90405
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7f8d7e3c981dde7089c3a117dc4bf643510abd80
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/cfef993dcc8fb513de79eb1f93cf26ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:a43e23beeb34e35f087462858f7088efbdb1585962f8781b7c3d59c98fc8060b
+size 138185
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..710ea6ce9e9c3303db2afa8b009eab2d6bfde771
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d43306249b8738ad82383c93fa310dcfc5df4daf88eb16d6b59e8f92d3d6a5de
+size 62801
diff --git a/marked/Y/T-REC-Y.4202-201902-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..045b8d9bb8fc796efb699a391257f0ce7083240d
--- /dev/null
+++ b/marked/Y/T-REC-Y.4202-201902-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5eda78e74927ccd90b1d003fcb3add2943ee5638e311e639501c32926bb7c95e
+size 27547
diff --git a/marked/Y/T-REC-Y.4205-201902-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.4205-201902-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..8423857338c7943fb53f6d62820e1de9b67a04e1
--- /dev/null
+++ b/marked/Y/T-REC-Y.4205-201902-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:da9f8de1f3eacbe3b5a5a51aa159e69515d35956d070ed38c2839f2d3b43bc36
+size 4216
diff --git a/marked/Y/T-REC-Y.4205-201902-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg b/marked/Y/T-REC-Y.4205-201902-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..370f95aa171d6f4a1dcf3f8bc020c1bdbf0ffdfb
--- /dev/null
+++ b/marked/Y/T-REC-Y.4205-201902-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5230e563c4b5b10b481abc8db65e438f51da66d7ab332bf79aaaa5c0be2b2683
+size 60704
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/03498c9b76f980b32f2dfbb7c2e539d2_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/03498c9b76f980b32f2dfbb7c2e539d2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..41bb769bfb51881643c734b33ea36a8620cf3ded
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/03498c9b76f980b32f2dfbb7c2e539d2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3fbe6d46d5d31976efb396d8a1554f7952514674412051f6ef26fa5dacea7ba3
+size 71716
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/08dce7ad4c512fdf0c0cde60415fade6_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/08dce7ad4c512fdf0c0cde60415fade6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..37e2bd65a057ed805c53662f0f2fc2799756d63f
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/08dce7ad4c512fdf0c0cde60415fade6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f61989281fd77f6ed9efe8347824a24c8fb1475d6bf56301e5759f2b0898a8f7
+size 60759
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/15e4a144a88176b71ea3eff2722253b0_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/15e4a144a88176b71ea3eff2722253b0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..5858dc8e7f407522f2fd8ecd27054b41d437da65
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/15e4a144a88176b71ea3eff2722253b0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f7c22f0e349fb19d728c3fe7cb0bb2da22c328dd7dc0db07f23caf4bf8bcfbbf
+size 35930
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..96a8531b8554b7723cc4b071c0ada7c264b3c4a4
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:fabbe7a4ef7a4ac56929bca4c03d2883ea51229bd01a5f8437ab7eaf24daa50b
+size 39460
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3e2c300a408fdedc5aba59c00d1af5e35abb91eb
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/4cde160bcc69b7b6c81b648dd0e4252e_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:775eaac1770d92176a042029999f6bdbcf8a4429240cc0042e5720f7c660479f
+size 44007
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/51536f203c07ce20ce119e7e09b11cb6_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/51536f203c07ce20ce119e7e09b11cb6_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ae7923174e78cecb0138bc200615cbbfc4052fb7
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/51536f203c07ce20ce119e7e09b11cb6_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:02dfc60d1d2bd70151e2feceb5e5e68533b44ba9acd2f325fae1778b6d8f61d6
+size 39060
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c243c45d5b370c602751b744179d3937a477f3f9
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/8e14350b4b669119a3bdfca7869110ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e62eac7045d0a055bc9623468893527766f5feb6422cf7c3144c80816b0dfad3
+size 21022
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..072f073b6d42cbfa77c827c76c611f286177034a
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/a3dc41dc3df86ea68d266af2bf95cf5b_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ee72ddf991b7b1d543b2694b1687804845ecb97da77cc35e98e4c7dbf5ac163d
+size 4142
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..458777db60033334c0265628bbfb14ed22cbfe89
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/c494cd874a082a97b50b3c4d3938f467_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:93ccb3da5363b763e3b7c8820be26a061719d88e8f7f62551642de60a69473fe
+size 39333
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e689e7348804c89f9a7674dbe854bcf7c19e6ff3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/fa859e4e468bfb2710a94527f2c504af_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:537bfdfd9faa5441cf538366ab7487c32b197c42657afe225d5ae37c49a64877
+size 63328
diff --git a/marked/Y/T-REC-Y.4210-202008-I_PDF-E/raw.md b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..3db0f1aa1c47e38659c7edd9aaf0574541d8fbb7
--- /dev/null
+++ b/marked/Y/T-REC-Y.4210-202008-I_PDF-E/raw.md
@@ -0,0 +1,1354 @@
+
+
+# ITU-T
+
+TELECOMMUNICATION
+STANDARDIZATION SECTOR
+OF ITU
+
+## Y.4210
+
+(08/2020)
+
+SERIES Y: GLOBAL INFORMATION
+INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS,
+NEXT-GENERATION NETWORKS, INTERNET OF
+THINGS AND SMART CITIES
+
+Internet of things and smart cities and communities –
+Requirements and use cases
+
+# --- **Requirements and use cases for universal communication module of mobile IoT devices**
+
+Recommendation ITU-T Y.4210
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## GLOBAL INFORMATION INFRASTRUCTURE, INTERNET PROTOCOL ASPECTS, NEXT-GENERATION NETWORKS, INTERNET OF THINGS AND SMART CITIES
+
+## GLOBAL INFORMATION INFRASTRUCTURE
+
+| | |
+|-------------------------------------------|-------------|
+| General | Y.100–Y.199 |
+| Services, applications and middleware | Y.200–Y.299 |
+| Network aspects | Y.300–Y.399 |
+| Interfaces and protocols | Y.400–Y.499 |
+| Numbering, addressing and naming | Y.500–Y.599 |
+| Operation, administration and maintenance | Y.600–Y.699 |
+| Security | Y.700–Y.799 |
+| Performances | Y.800–Y.899 |
+
+## INTERNET PROTOCOL ASPECTS
+
+| | |
+|--------------------------------------------------------------------|---------------|
+| General | Y.1000–Y.1099 |
+| Services and applications | Y.1100–Y.1199 |
+| Architecture, access, network capabilities and resource management | Y.1200–Y.1299 |
+| Transport | Y.1300–Y.1399 |
+| Interworking | Y.1400–Y.1499 |
+| Quality of service and network performance | Y.1500–Y.1599 |
+| Signalling | Y.1600–Y.1699 |
+| Operation, administration and maintenance | Y.1700–Y.1799 |
+| Charging | Y.1800–Y.1899 |
+| IPTV over NGN | Y.1900–Y.1999 |
+
+## NEXT GENERATION NETWORKS
+
+| | |
+|-------------------------------------------------------------------|---------------|
+| Frameworks and functional architecture models | Y.2000–Y.2099 |
+| Quality of Service and performance | Y.2100–Y.2199 |
+| Service aspects: Service capabilities and service architecture | Y.2200–Y.2249 |
+| Service aspects: Interoperability of services and networks in NGN | Y.2250–Y.2299 |
+| Enhancements to NGN | Y.2300–Y.2399 |
+| Network management | Y.2400–Y.2499 |
+| Network control architectures and protocols | Y.2500–Y.2599 |
+| Packet-based Networks | Y.2600–Y.2699 |
+| Security | Y.2700–Y.2799 |
+| Generalized mobility | Y.2800–Y.2899 |
+| Carrier grade open environment | Y.2900–Y.2999 |
+
+## FUTURE NETWORKS
+
+Y.3000–Y.3499
+
+### CLOUD COMPUTING
+
+Y.3500–Y.3599
+
+### BIG DATA
+
+Y.3600–Y.3799
+
+### QUANTUM KEY DISTRIBUTION NETWORKS
+
+Y.3800–Y.3999
+
+### INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES
+
+| | |
+|---------------------------------------------------------|----------------------|
+| General | Y.4000–Y.4049 |
+| Definitions and terminologies | Y.4050–Y.4099 |
+| Requirements and use cases | Y.4100–Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250–Y.4399 |
+| Frameworks, architectures and protocols | Y.4400–Y.4549 |
+| Services, applications, computation and data processing | Y.4550–Y.4699 |
+| Management, control and performance | Y.4700–Y.4799 |
+| Identification and security | Y.4800–Y.4899 |
+| Evaluation and assessment | Y.4900–Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+## Recommendation ITU-T Y.4210
+
+# Requirements and use cases for universal communication module of mobile IoT devices
+
+## Summary
+
+As an important part of mobile Internet of things (IoT) devices, the universal communication module is a key component to achieve economies of scale for mobile IoT devices, accelerate the progress of research and development, and promote the application of new mobile IoT technologies.
+
+Recommendation ITU-T Y.4210 specifies requirements for a universal communication module of mobile IoT devices.
+
+Related use cases are provided in Appendix I. Universal communication module reference types are described in Appendix II.
+
+## History
+
+| Edition | Recommendation | Approval | Study Group | Unique ID* |
+|---------|----------------|------------|-------------|---------------------------------------------------------------------------|
+| 1.0 | ITU-T Y.4210 | 2020-08-29 | 20 | 11.1002/1000/14371 |
+
+## Keywords
+
+Mobile IoT device, universal communication module.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID. For example, .
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at .
+
+© ITU 2020
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | | Page |
+|----|---------------------------------------------------------------------------------------|-------------|
+| 1 | Scope..... | 1 |
+| 2 | References..... | 1 |
+| 3 | Definitions ..... | 2 |
+| | 3.1 Terms defined elsewhere..... | 2 |
+| | 3.2 Terms defined in this Recommendation..... | 3 |
+| 4 | Abbreviations and acronyms ..... | 3 |
+| 5 | Conventions ..... | 4 |
+| 6 | Concept of universal communication module of mobile IoT devices..... | 4 |
+| 7 | Universal communication module classification..... | 5 |
+| | 7.1 Universal communication module characteristics..... | 5 |
+| | 7.2 Universal communication module classification factors..... | 6 |
+| 8 | Mechanical requirements..... | 7 |
+| | 8.1 Mechanical requirements for small size universal communication module .. | 7 |
+| | 8.2 Mechanical requirements for normal size universal communication module ..... | 9 |
+| 9 | Electrical requirements ..... | 12 |
+| | 9.1 Power supply interface ..... | 12 |
+| | 9.2 Module control and status interface ..... | 12 |
+| | 9.3 RF interface ..... | 13 |
+| | 9.4 SIM/USIM interface..... | 14 |
+| | 9.5 Data input/output interfaces ..... | 14 |
+| | 9.6 Analogue interface..... | 16 |
+| | 9.7 Audio interface ..... | 16 |
+| 10 | Software requirements ..... | 16 |
+| | 10.1 Universal communication module management ..... | 17 |
+| | 10.2 Debugging function ..... | 17 |
+| | 10.3 Minimum AT commands ..... | 17 |
+| 11 | Performance requirements ..... | 20 |
+| | 11.1 Storage..... | 20 |
+| | 11.2 Temperature..... | 20 |
+| | Appendix I – Use cases for universal communication module of mobile IoT devices ..... | 21 |
+| | I.1 Smart utility metering..... | 21 |
+| | I.2 Smart home..... | 21 |
+
+| | Page |
+|--------------------------------------------------------------------|-------------|
+| Appendix II – Universal communication module reference types ..... | 23 |
+| II.1 Universal communication module reference Type 1..... | 23 |
+| II.2 Universal communication module reference Type 2..... | 24 |
+| II.3 Universal communication module reference Type 3..... | 26 |
+| II.4 Universal communication module reference Type 4..... | 29 |
+| Bibliography..... | 32 |
+
+## Recommendation ITU-T Y.4210
+
+# Requirements and use cases for universal communication module of mobile IoT devices
+
+# 1 Scope
+
+Currently, the communication modules produced by different vendors of modules for mobile Internet of things (IoT) devices have different designs, which results in a fragmented communication module market and low compatibility. The universal communication module is a key component to achieve economies of scale for mobile IoT devices, accelerate the progress of research and development and promote the application of new mobile IoT technologies.
+
+This Recommendation introduces the concept of a universal communication module of mobile IoT devices, analyses the requirements for universal communication module implementations of mobile IoT devices, and provides use cases for the universal communication module of mobile IoT devices.
+
+In this Recommendation, the universal communication module actually represents a series of communication modules.
+
+The communication technologies related to all the communication modules which are addressed in this Recommendation – and used by mobile IoT devices – are the 3GPP low power wide area (LPWA) technologies (currently, narrow band-Internet of things (NB-IoT) [b-3GPP TS 36.300] and enhanced machine type communication (eMTC) [b-3GPP TS 36.300]).
+
+Different communication modules can apply to different IoT application scenarios, such as smart utility metering, smart home, logistics tracking, smart bicycles, intelligent buildings and so on.
+
+The scope of this Recommendation includes:
+
+- concept and classification of universal communication module of mobile IoT devices;
+- requirements of universal communication module of mobile IoT devices – considering the requirements for the different communication module types of mobile IoT devices;
+- use cases of universal communication module of mobile IoT devices.
+
+## 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+[ETSI TS 127 005] ETSI TS 127 005 V14.0.0 (2017-04), *Digital cellular telecommunications system (Phase 2+) (GSM); Universal Mobile Telecommunications System (UMTS); LTE; Use of Data Terminal Equipment – Data Circuit terminating Equipment (DTE – DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) (3GPP TS 27.005 version 14.0.0 Release 14)*.
+
+[ETSI TS 127 007] *ETSI TS 127 007 V13.7.0 (2018-04), Digital cellular telecommunications system (Phase 2+) (GSM); Universal Mobile Telecommunications System (UMTS); LTE; AT command set for User Equipment (UE) (3GPP TS 27.007 version 13.7.0 Release 13).*
+
+## 3 Definitions
+
+### 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 application** [b-ITU-T Y.2091]: A structured set of capabilities, which provide value-added functionality supported by one or more services, which may be supported by an API interface.
+
+**3.1.2 capability** [b-ITU-R M.1224-1]: The ability of an item to meet a service demand of given quantitative characteristics under given internal conditions.
+
+**3.1.3 Internet of things (IoT)** [b-ITU-T Y.2060]: A global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on, existing and evolving, interoperable information and communication technologies.
+
+NOTE 1 – Through the exploitation of identification, data capture, processing and communication capabilities, the IoT makes full use of things to offer services to all kinds of applications, whilst ensuring that security and privacy requirements are fulfilled.
+
+NOTE 2 – In a broad perspective, the IoT can be perceived as a vision with technological and societal implications.
+
+**3.1.4 thing** [b-ITU-T Y.2060]: In the Internet of things, this is an object of the physical world (physical things) or of the information world (virtual things), which is capable of being identified and integrated into the communication networks.
+
+**3.1.5 attention (AT)** [b-3GPP TS 27.007]: It is always used to start a command line to be sent from terminal equipment (TE) to terminal adaptor (TA).
+
+**3.1.6 terminal equipment (TE)** [b-3GPP TS 27.007]: Terminal equipment, such as a computer, equal to data terminal equipment (DTE).
+
+**3.1.7 terminal adaptor (TA)** [b-3GPP TS 27.007]: Terminal adaptor (TA) such as a global system for mobile communication (GSM) data card, equal to data circuit terminating equipment (DCE).
+
+**3.1.8 service centre** [b-3GPP TS 23.040]: Function responsible for the relaying and storage and forwarding of a short message between a short message entity (SME) and a mobile subscriber (MS).
+
+**3.1.9 short message entity (SME)** [b-3GPP TS 23.040]: Entity which may send or receive short messages.
+
+**3.1.10 cellular IoT (CIoT)** [b-3GPP TS 23.401]: Cellular network supporting low complexity and low throughput devices for a network of things.
+
+**3.1.11 extended idle mode DRX (eDRX)** [b-3GPP TS 23.682]: The user equipment (UE) and the network may negotiate over non-access stratum signalling the use of extended idle mode discontinuous reception (DRX) for reducing its power consumption, while being available for mobile terminating data and/or network originated procedures within a certain delay dependent on the DRX cycle value.
+
+### 3.2 Terms defined in this Recommendation
+
+This Recommendation defines the following terms:
+
+**3.2.1 package:** A casing that holds the circuit.
+
+NOTE – With the package, on one hand, the circuit can be protected from corrosion or physical damage; on the other hand, the circuit still has electrical contacts which can be connected with a printed circuit board.
+
+**3.2.2 pad:** Physical contact on a module.
+
+**3.2.3 pad spacing:** Distance between two adjacent pads on a common row or column of a module.
+
+## 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|-------------------------------------------------------|
+| ADC | Analogue-to-Digital Converter |
+| APN | Access Point Name |
+| AT | Attention |
+| CIoT | Cellular IoT |
+| DC | Direct Current |
+| DCE | Data Circuit terminating Equipment |
+| DRX | Discontinuous Reception |
+| DTE | Data Terminal Equipment |
+| EDGE | Enhanced Data rate for GSM Evolution |
+| eDRX | Extended idle mode DRX |
+| eMTC | enhanced Machine Type Communication |
+| GNSS | Global Navigation Satellite System |
+| GPIO | General Purpose Input Output |
+| GPRS | General Packet Radio Service |
+| GSM | Global System for Mobile Communication |
+| I2C | Inter-Integrated Circuit bus |
+| I2S | Integrated Inter Chip Sound |
+| IMEI | International Mobile Equipment Identity |
+| IMSI | International Mobile Subscriber Identification Number |
+| IoT | Internet of Things |
+| IP | Internet Protocol |
+| LCC | Leadless Chip Carriers |
+| LGA | Land Grid Array |
+| LPWA | Low Power Wide Area |
+| MCU | Microcontroller Unit |
+| MS | Mobile Subscriber |
+| NB-IoT | Narrow Band-Internet of Things |
+
+| | |
+|------|---------------------------------------------|
+| PCM | Pulse Code Modulation |
+| PDU | Protocol Data Unit |
+| PLMN | Public Land Mobile Network |
+| RF | Radio Frequency |
+| RTC | Real Time Clock |
+| SDK | Software Development Kit |
+| SIM | Subscriber Identity Module |
+| SME | Short Message Entity |
+| SMS | Short Message Service |
+| SN | Serial Number |
+| SPI | Serial Peripheral Interface |
+| TA | Terminal Adaptor |
+| TBD | To Be Determined |
+| TE | Terminal Equipment |
+| UART | Universal Asynchronous Receiver/Transmitter |
+| UE | User Equipment |
+| URL | Uniform Resource Locator |
+| USB | Universal Serial Bus |
+| USIM | Universal Subscriber Identity Module |
+
+## 5 Conventions
+
+The following conventions are used in this Recommendation:
+
+- The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted, if conformance to this Recommendation is to be claimed.
+- The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement need not be present to claim conformance.
+- The keywords "can optionally" and "may" indicate an optional requirement which is permissible, without implying any sense of being recommended. These terms are not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+## 6 Concept of universal communication module of mobile IoT devices
+
+As an important part of mobile IoT devices, the universal communication module is a key component to achieve economies of scale for mobile IoT devices, accelerate the progress of research and development, and promote the application of new mobile IoT technologies.
+
+A universal communication module of mobile IoT devices is required to include a baseband unit and a radio frequency (RF) front end unit, as shown in Figure 1.
+
+A universal communication module of mobile IoT devices may also include a microcontroller unit (MCU), a global navigation satellite system (GNSS) positioning unit, a sensor unit, a subscriber identity module (SIM)/universal subscriber identity module (USIM) card and an antenna.
+
+NOTE – The baseband unit and RF front end unit are the key parts for communication. The baseband unit and the RF front end unit are mandatory.
+
+As the processing capability of the MCU unit embedded in the communication module may not meet the requirements, another MCU (not embedded in the communication module) may be used. The MCU unit is optional.
+
+The GNSS unit is useful for positioning based services. Because of its specific applicability, the GNSS unit is optional.
+
+The SIM/USIM card can be supplied by different vendors. The SIM/USIM card is optional.
+
+The size of the antenna depends on the frequencies. The antenna is optional.
+
+The selection of sensors depends on user requirements. The sensor unit is optional.
+
+
+
+Figure 1: Structure of a universal communication module of mobile IoT device. The diagram shows a rectangular box representing the module. Inside, there are two solid-line boxes at the top: 'Baseband' on the left and 'RF front end' on the right. Below these, there is a dashed-line box containing five components: 'MCU', 'GNSS', 'Sensor', 'SIM/USIM card', and 'Antenna' from left to right. The label 'Y.4210(20)\_F01' is located at the bottom right of the diagram.
+
+**Figure 1 – Structure of a universal communication module of mobile IoT device**
+
+## **7 Universal communication module classification**
+
+### **7.1 Universal communication module characteristics**
+
+To facilitate mobile IoT device development, the following common characteristics are based on the collection and selection of characteristics from diverse mobile IoT application scenarios, including mechanical characteristics, electrical characteristics, software characteristics, performance characteristics, application scope characteristics and communication mode characteristics.
+
+#### **1) Mechanical characteristics:**
+
+- Package: including but not limited to leadless chip carriers (LCC) [b-Information Package-1] and land grid array (LGA) [b-Information Package-2].
+
+NOTE 1 – LCC and LGA are widely used packages in current mobile IoT modules industry.
+
+- Size: length, width and thickness.
+
+NOTE 2 – Different application requirements have an effect on the module size.
+
+- Pad size and pad spacing
+- Pad assignments
+
+#### **2) Electrical characteristics:**
+
+- Power supply interface, used to supply the power for universal communication modules.
+
+NOTE 3 – Power supply voltage is a key indicator of power consumption in current mobile IoT modules industry.
+
+- RF interface, used to send or receive wireless signals for universal communication modules.
+
+NOTE 4 – A single RF interface is widely used in current mobile IoT modules industry.
+
+NOTE 5 – In case of position based service support, an additional RF interface for GNSS is usually used.
+
+- Module control and status interface, used to control universal communication modules: including but not limited to Power on/off, Reset, Wakeup.
+ - SIM/USIM [b-ETSI TS 102 671] interface, used to connect SIM/USIM card with universal communication modules.
+ - Data input/output interfaces, used to implement data exchange between universal communication modules and external circuits: including but not limited to universal asynchronous receiver/transmitter (UART) [b-Information Electrical-Interface-2], general purpose input output (GPIO) [b-Information Electrical-Interface-1], inter-integrated circuit bus (I2C) [b-Information Electrical-Interface-1], serial peripheral interface (SPI) [b-Information Electrical-Interface-1] and universal serial bus (USB) [b-Information Electrical-Interface-2].
+ - Analogue interface, used to convert an analogue signal into a digital signal by universal communication modules: including but not limited to analogue-to-digital converter (ADC) [b-Information Electrical-Interface-1].
+ - Audio interface, used to support voice communication by universal communication modules: including but not limited to pulse code modulation (PCM) [b-Information Electrical-Interface-1] and integrated inter chip sound (I2S) [b-Information Electrical-Interface-1].
+- 3) Software characteristics:
+- Universal module management, for maintainability and usability of communication modules.
+ - Debugging function, to debug the universal communication modules.
+ - Minimum AT commands, for software development compatibility of universal communication modules.
+- 4) Performance characteristics:
+- Storage
+ - Temperature
+- 5) Application scope characteristics:
+- The application scope deals with the applications the communication module is used for: consumer applications, industrial applications and vehicle applications.
+- 6) Communication mode characteristics:
+- Communication modes: as examples, global system for mobile communication (GSM)/general packet radio service (GPRS)/ enhanced data rate for GSM evolution (EDGE) [b-3GPP TS 05.01], NB-IoT, eMTC.
+
+NOTE 6 – Based on application scenarios, a communication module may have one or more communication modes.
+
+### 7.2 Universal communication module classification factors
+
+The universal communication module is recommended to comply with the following requirements.
+
+- Every type of universal communication module is recommended to cover a large variety of application scenarios.
+- Every universal communication module of a given type (i.e., small size or normal size as identified in this clause) is recommended to be compatible with other universal communication modules of the same type.
+
+NOTE 1 – Electrical requirements and software requirements are common to both types of universal communication module. The mechanical requirements differ among the different universal communication module types.
+
+The universal communication module classification factors are shown in Figure 2 and described below.
+
+| | | |
+|-------------------------|-------------------|---------------------|
+| Mechanical requirements | Application scope | Communication modes |
+|-------------------------|-------------------|---------------------|
+
+Y.4210(20)\_F02
+
+**Figure 2 – Universal communication module classification factors**
+
+#### 1) Mechanical requirements:
+
+The mechanical requirements are the key factor. This includes, but is not limited to, the following aspects: layout (package and size), pad size and spacing, and pad assignments.
+
+Layout is used to ensure the same package, same length and same width for universal communication modules of a given type.
+
+Pad size and spacing are used to ensure the same pad size for universal communication module of a given type.
+
+Pad assignments are used to ensure the same pad assignments for universal communication modules of a given type.
+
+While the module size becomes smaller, the number of pads decreases, and the functional capabilities of the universal communication module are reduced; while the module size becomes bigger, the number of pads increases, and the functional capabilities of universal communication module are enhanced.
+
+NOTE 2 – Based on different mechanical requirements, two universal communication module types are identified as described in clause 8: Small size universal communication module (recommended size less than 20mm\*20mm) and normal size universal communication module (recommended size more than 20mm\*20mm and less than 30mm\*30mm) [b-GSMA-Module].
+
+#### 2) Application scope:
+
+The application scope factor addresses three categories of applications: consumer category, industrial category and vehicle category.
+
+#### 3) Communication modes:
+
+The communication modes factor is classified according to two categories:
+
+- Single mode: NB-IoT or eMTC (NB-IoT/eMTC)
+- Multimode: NB-IoT and eMTC; NB-IoT and GSM; NB-IoT, eMTC and GSM.
+
+## 8 Mechanical requirements
+
+A universal communication module of mobile IoT device is recommended to meet the following mechanical requirements according to the communication module type (small size or normal size).
+
+### 8.1 Mechanical requirements for small size universal communication module
+
+This type of universal communication module is recommended for NB-IoT/eMTC single mode. The application target of this type of universal communication module includes NB-IoT/eMTC applications such as smart utility metering, smart home, intelligent buildings.
+
+It is recommended to use LCC or LGA package.
+
+Figure 3 shows a recommended layout for a small size universal communication module.
+
+
+
+Figure 3: Recommended layout for small size universal communication module. The diagram shows a rectangular layout of 40 numbered pads (1-40) arranged in a 4x10 grid. Pads 1-10 are on the right, 11-20 on the top, 21-30 on the left, and 31-40 on the bottom. Dimensions are indicated by arrows: ① represents the overall size of the module, ② represents the size of a pad, ③ represents the size of pad spacing, and ④ represents the edge spacing. The text 'Y.4210(20)\_F03' is located at the bottom right of the diagram.
+
+**Figure 3 – Recommended layout for small size universal communication module**
+
+In Figure 3: ① represents the size of the universal communication module; ② represents the size of the pad; ③ represents the size of pad spacing; ④ represents the edge spacing. Table 1 gives recommended pad assignments for this layout.
+
+**Table 1 – Recommended pad assignments for small size universal communication module**
+
+| Pad No. | Pad name | Pad description |
+|---------|--------------|----------------------------------|
+| 1 | UART2_TXD | TXD for the 2 nd UART |
+| 2 | UART2_RXD | RXD for the 2 nd UART |
+| 3 | SPI_SS | SS for SPI |
+| 4 | SPI_MISO | MISO for SPI |
+| 5 | SPI_MOSI | MOSI for SPI |
+| 6 | SPI_SCLK | SCLK for SPI |
+| 7 | UART1_CTS | CTS for the 1 st UART |
+| 8 | UART1_RTS | RTS for the 1 st UART |
+| 9 | UART1_TXD | TXD for the 1 st UART |
+| 10 | UART1_RXD | RXD for the 1 st UART |
+| 11 | USIM_DETECT | DETECT for USIM |
+| 12 | USIM_RESET | RESET for USIM |
+| 13 | USIM_CLK | CLK for USIM |
+| 14 | USIM_DATA | DATA for USIM |
+| 15 | USIM_VCC | Power supply for USIM |
+| 16 | WAKEUP_OUT | Module wakes up host |
+| 17 | RESET | Reset |
+| 18 | WAKEUP_IN | Host wakes up module |
+| 19 | POWER_ON/OFF | Power on/off |
+
+**Table 1 – Recommended pad assignments for small size universal communication module**
+
+| Pad No. | Pad name | Pad description |
+|---------|-----------|-----------------------------------|
+| 20 | VDD | Reference logic level from module |
+| 21 | SYS_STATE | Module status indication |
+| 22 | GND | Ground |
+| 23 | GND | Ground |
+| 24 | GNSS_ANT | GNSS antenna |
+| 25 | GND | Ground |
+| 26 | GND | Ground |
+| 27 | ANT0 | Antenna |
+| 28 | GND | Ground |
+| 29 | GND | Ground |
+| 30 | GND | Ground |
+| 31 | VCC1 | Power supply |
+| 32 | VCC2 | Power supply |
+| 33 | RTC Power | Power supply for RTC |
+| 34 | GPIO | General purpose Input/Output |
+| 35 | GPIO | General purpose Input/Output |
+| 36 | I2C_SCL | SCL for I 2 C |
+| 37 | I2C_SDA | SDA for I 2 C |
+| 38 | ADC | Analogue-to-Digital Converter |
+| 39 | RESERVED | To Be Determined (TBD) |
+| 40 | RESERVED | TBD |
+
+NOTE – Appendices II.1 and II.2 describe the reference types for the small size universal communication module.
+
+### **8.2 Mechanical requirements for normal size universal communication module**
+
+This type of universal communication module is recommended for multimode.
+
+This type of universal communication module has a general application target.
+
+It is recommended to use LCC or LGA package.
+
+Figure 4 shows a recommended layout for normal size universal communication module.
+
+
+
+Figure 4: Recommended layouts for normal size universal communication module. The diagram shows a rectangular layout of 52 pads arranged in a U-shape. The pads are numbered 1 through 52. The layout is defined by four dimensions: ① (module size), ② (pad size), ③ (pad spacing), and ④ (edge spacing). The pads are arranged in four rows: 15 pads on the top edge (15 to 26), 14 pads on the right edge (1 to 14), 12 pads on the left edge (27 to 40), and 11 pads on the bottom edge (41 to 52). The dimensions are indicated by arrows and labels: ① is the overall width and height, ② is the width of a single pad, ③ is the spacing between pads, and ④ is the spacing from the edge to the first pad.
+
+**Figure 4 – Recommended layouts for normal size universal communication module**
+
+In Figure 4: ① represents the size of the universal communication module; ② represents the size of the pad; ③ represents the size of pad spacing; ④ represents the edge spacing. Table 2 gives recommended pad assignments for this layout.
+
+**Table 2 – Recommended pad assignments for normal size universal communication module**
+
+| Pad No. | Pad name | Pad description |
+|---------|-----------|----------------------------------|
+| 1 | UART1_TXD | TXD for the 1 st UART |
+| 2 | UART1_RXD | RXD for the 1 st UART |
+| 3 | UART1_CTS | CTS for the 1 st UART |
+| 4 | UART1_RTS | RTS for the 1 st UART |
+| 5 | SPI_SS | SS for SPI |
+| 6 | SPI_MISO | MISO for SPI |
+| 7 | SPI_MOSI | MOSI for SPI |
+| 8 | SPI_SCLK | SCLK for SPI |
+| 9 | USIM_VCC | Power supply for USIM |
+
+**Table 2 – Recommended pad assignments for normal size universal communication module**
+
+| Pad No. | Pad name | Pad description |
+|---------|--------------|-----------------------------------|
+| 10 | USIM_RESET | RESET for USIM |
+| 11 | USIM_DATA | DATA for USIM |
+| 12 | USIM_CLK | CLK for USIM |
+| 13 | USIM_GND | Ground for USIM |
+| 14 | USIM_DETECT | DETECT for USIM |
+| 15 | RTC Power | Power supply for RTC |
+| 16 | VCC1 | Power supply |
+| 17 | VCC2 | Power supply |
+| 18 | GND | Ground |
+| 19 | GND | Ground |
+| 20 | GND | Ground |
+| 21 | GND | Ground |
+| 22 | GNSS_ANT | GNSS antenna |
+| 23 | GND | Ground |
+| 24 | GND | Ground |
+| 25 | ANT0 | Antenna |
+| 26 | GND | Ground |
+| 27 | USB_Dp | USB data (positive) |
+| 28 | USB_Dn | USB data (negative) |
+| 29 | VBUS | USB detect |
+| 30 | GND | Ground |
+| 31 | ADC | Analogue-to-Digital Converter |
+| 32 | GND | Ground |
+| 33 | GPIO | General purpose Input/Output |
+| 34 | GPIO | General purpose Input/Output |
+| 35 | GPIO | General purpose Input/Output |
+| 36 | GPIO | General purpose Input/Output |
+| 37 | WAKEUP_OUT | Module wakes up host |
+| 38 | RESET | Reset |
+| 39 | WAKEUP_IN | Host wakes up module |
+| 40 | POWER_ON/OFF | Power on/off |
+| 41 | VDD | Reference logic level from module |
+| 42 | SYS_STATE | Module status indication |
+| 43 | UART2_TXD | TXD for the 2 nd UART |
+| 44 | UART2_RXD | RXD for the 2 nd UART |
+| 45 | I2C_SCL | SCL for I 2 C |
+| 46 | I2C_SDA | SDA for I 2 C |
+| 47 | RESERVED | TBD |
+| 48 | RESERVED | TBD |
+
+**Table 2 – Recommended pad assignments for normal size universal communication module**
+
+| Pad No. | Pad name | Pad description |
+|---------|----------|-----------------|
+| 49 | RESERVED | TBD |
+| 50 | RESERVED | TBD |
+| 51 | RESERVED | TBD |
+| 52 | RESERVED | TBD |
+
+NOTE – Appendices II.3 and II.4 describe the reference types for the normal size universal communication module.
+
+## 9 Electrical requirements
+
+A universal communication module of mobile IoT device is recommended to meet the following electrical requirements, including power supply interface, module control and status interface, RF interface, SIM/USIM interface, data input/output interface, analogue interface and audio interface.
+
+### 9.1 Power supply interface
+
+#### 9.1.1 DC power supply interface
+
+Universal communication modules are required to support a direct current (DC) power supply interface. Table 3 provides a DC power supply interface description.
+
+**Table 3 – DC power supply interface description**
+
+| Interface type | Pad name | Description | Type |
+|------------------------|-------------------------------|--------------------------|-------|
+| Power supply interface | VCC n , n=0,1, ... | External DC power supply | Input |
+
+#### 9.1.2 RTC power supply interface
+
+Universal communication modules may support a real time clock (RTC) power supply interface. Table 4 provides a RTC power supply interface description.
+
+**Table 4 – RTC power supply interface description**
+
+| Interface type | Pad name | Description | Type |
+|------------------------|-----------|--------------------------|-------|
+| Power supply interface | RTC Power | Module clock power input | Input |
+
+NOTE – RTC power supply interface is used to ensure that the internal clock of universal communication modules can still work even if DC power supply doesn't work.
+
+### 9.2 Module control and status interface
+
+#### 9.2.1 Power switch and status indication interface
+
+Universal communication modules are recommended to support a power switch and status indication interface. Table 5 provides a power switch and status indication interface description.
+
+**Table 5 – Power switch and status indication interface description**
+
+| Interface type | Pad name | Description | Type |
+|------------------------------|--------------|-----------------------------------------|--------|
+| Control and status interface | POWER_ON/OFF | Power switch to power on/off the module | Input |
+| | SYS_STATE | Indication of module current status. | Output |
+
+#### 9.2.2 Module reset interface
+
+Universal communication modules are required to support a module reset interface. Table 6 provides a module reset interface description.
+
+**Table 6 – Module reset interface description**
+
+| Interface type | Pad name | Description | Type |
+|------------------------------|----------|-----------------------|-------|
+| Control and status interface | RESET | Used for module reset | Input |
+
+#### 9.2.3 Module wakeup interface
+
+Universal communication modules may support module wakeup interface. Table 7 provides a module wakeup interface description.
+
+**Table 7 – Module wakeup interface description**
+
+| Interface type | Pad Name | Description | Type |
+|------------------------------|------------|-------------------------------------------|--------|
+| Control and status interface | WAKEUP_IN | For external device to wake up the module | Input |
+| | WAKEUP_OUT | For module to wake up other devices | Output |
+
+#### 9.2.4 Reference voltage of VDD output interface
+
+Universal communication modules may support a reference voltage of VDD output interface. Table 8 provides a reference voltage of VDD output interface description.
+
+**Table 8 – Reference voltage of VDD output interface description**
+
+| Interface type | Pad name | Description | Type |
+|------------------------------|----------|------------------------------------|--------|
+| Control and status interface | VDD | Reference voltage output interface | Output |
+
+NOTE – Reference voltage of VDD output interface is used to supply the standard power for circuits external to the universal communication module.
+
+### 9.3 RF interface
+
+Universal communication modules are required to support ANT0 interface (main antenna interface) and may support GNSS ANT interface. Table provides a 9 RF interface description.
+
+**Table – 9 RF interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------|-------------------------------|--------------|--------------|
+| Radio interface | ANT n , n=0,1, ... | Main antenna | Input/Output |
+| | GNSS_ANT | GNSS antenna | Input |
+
+NOTE – GNSS ANT interface is used for position-based services.
+
+### 9.4 SIM/USIM interface
+
+Universal communication modules are required to support SIM/USIM interface. Table 10 provides a SIM/USIM interface description.
+
+**Table 10 – SIM/USIM interface description**
+
+| Interface type | Pad name | Description | Type |
+|----------------|-------------|--------------------|--------------|
+| USIM interface | USIM_GND | USIM ground | N/A |
+| | USIM_DETECT | USIM DETECT signal | Input |
+| | USIM_RESET | USIM RESET signal | Output |
+| | USIM_CLK | USIM CLK signal | Output |
+| | USIM_DATA | USIM DATA signal | Input/Output |
+| | USIM_VCC | USIM power output | Output |
+
+### 9.5 Data input/output interfaces
+
+#### 9.5.1 UART interface
+
+Universal communication modules are required to support a two-wire UART interface and are recommended to support four-wire UART interface. Table 11 provides a UART interface description.
+
+**Table 11 – UART interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------------------|------------------------------------|----------------------|--------|
+| Data Input/Output interface | UART n _RXD, n=0,1, ... | Receive data | Input |
+| | UART n _TXD, n=0,1, ... | Transmit data | Output |
+| | UART n _RTS, n=0,1, ... | Request to send data | Input |
+| | UART n _CTS, n=0,1, ... | Clear to send data | Output |
+
+NOTE – Two-wire UART interface only contains UART\_RXD and UART\_TXD interfaces. Four-wire UART interface contains UART\_RTS, UART\_CTS, UART\_RXD and UART\_TXD interfaces, which can supply more powerful communication capability.
+
+#### 9.5.2 GPIO interface
+
+Universal communication modules are recommended to support a GPIO interface. Table 12 provides a GPIO interface description.
+
+**Table 12 – GPIO interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------------------|--------------------------------|---------------------------------------------------------------------|--------------|
+| Data Input/Output interface | GPIO n , n=0,1, ... | General input /output interface with recommended interrupt function | Input/Output |
+
+#### 9.5.3 I2C interface
+
+Universal communication modules are recommended to support I2C interface. Table 13 provide a I2C interface description.
+
+**Table 13 – I2C interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------------------|----------|--------------------------|--------------|
+| Data Input/Output interface | I2C_SCL | Bidirectional clock line | Input/Output |
+| | I2C_SDA | Bidirectional data line | Input/Output |
+
+#### 9.5.4 SPI interface
+
+Universal communication modules are recommended to support SPI interface. Table 14 provides a SPI interface description.
+
+**Table 14 – SPI interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------------------|-------------------|------------------------------|--------|
+| Data Input/Output interface | SPI_SS | SS signal of SPI interface | Input |
+| | SPI_MISO/SPI_MISO | MISO signal of SPI interface | Output |
+| | SPI_MOSI/SPI_MOSI | MOSI signal of SPI interface | Input |
+| | SPI_SCLK/SPI_SCLK | SCLK signal of SPI interface | Input |
+
+#### 9.5.5 USB interface
+
+Universal communication modules may support USB interface. Table 15 provides a USB interface description.
+
+**Table 15 – USB interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------------------|----------|---------------------------------------------------|--------------|
+| Data Input/Output interface | USB_Dp | USB USB data signal lines (positive differential) | Input/Output |
+| | USB_Dn | USB USB data signal lines (negative differential) | Input/Output |
+| | VBUS | Power supply | Input |
+
+### 9.6 Analogue interface
+
+#### 9.6.1 ADC interface
+
+Universal communication modules may support ADC interface. Table 16 provides an ADC interface description.
+
+**Table 16 – ADC interface description**
+
+| Interface type | Pad name | Description | Type |
+|--------------------|-------------------------------|-------------------------|--------------|
+| Analogue interface | ADC n , n=0,1, ... | AD conversion interface | Input/Output |
+
+### 9.7 Audio interface
+
+#### 9.7.1 PCM interface
+
+Universal communication modules may support PCM interface. Table 17 provides a PCM interface description.
+
+**Table 17 – PCM interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------|----------|----------------------------|--------|
+| Audio interface | PCM_SYNC | PCM synchronization signal | Output |
+| | PCM_DIN | PCM input data | Input |
+| | PCM_DOUT | PCM output data | Output |
+| | PCM_CLK | PCM clock | Input |
+
+NOTE – PCM interface is used to support voice communication service.
+
+#### 9.7.2 I2S interface
+
+Universal communication modules may support I2S interface. Table 18 provides a I2S interface description.
+
+**Table 18 – I2S interface description**
+
+| Interface type | Pad name | Description | Type |
+|-----------------|----------|------------------------|--------------|
+| Audio interface | I2S_WS | I2S word select signal | Input/Output |
+| | I2S_DIN | I2S input data | Input |
+| | I2S_DOUT | I2S output data | Output |
+| | I2S_CLK | I2S clock | Input |
+
+NOTE – I2S interface is used to support voice communication service.
+
+## 10 Software requirements
+
+A universal communication module of a mobile IoT device is recommended to meet the following software requirements, including universal communication module management, debugging function and minimum AT commands.
+
+### **10.1 Universal communication module management**
+
+In order to improve the maintainability and usability of universal communication modules, it is required to support universal communication module management which includes module identification management, module status management, firmware upgrading management, module parameters profile management, module communication management and module SIM/USIM interface management.
+
+#### **10.1.1 Module identification management**
+
+In order to allow IoT platforms to manage mobile IoT devices, universal communication modules are required to be identified. Module identification is recommended to include but not limited to the following identification methods: international mobile equipment identity (IMEI), international mobile subscriber identification number (IMSI) and serial number (SN).
+
+#### **10.1.2 Module status management**
+
+Universal communication modules are recommended to support module status detection and management, including but not limited to hardware status, software status and communication status.
+
+#### **10.1.3 Firmware upgrading management**
+
+Universal communication modules are recommended to support firmware upgrade, including local firmware upgrade and remote firmware upgrade over the air.
+
+#### **10.1.4 Module parameters profile management**
+
+Universal communication modules are recommended to pre-set cellular network configuration parameters, including but not limited to access point name (APN), short message service (SMS) service centre address, IoT platform Internet protocol (IP) address or uniform resource locator (URL) and port number.
+
+#### **10.1.5 Module communication management**
+
+Universal communication modules are recommended to support IPv6.
+
+Detailed optional support related to IPv6 may be based on GSMA TS.34 (clause 5.3) [b-GSMA TS.34].
+
+#### **10.1.6 Module SIM/USIM interface management**
+
+Universal communication modules are recommended to support SIM/USIM interface management to enable SIM/USIM over the air management and remote provisioning.
+
+Detailed optional support for SIM/USIM over the air management and remote provisioning may be based on GSMA TS.34 (clause 5.6) [b-GSMA TS.34].
+
+### **10.2 Debugging function**
+
+Universal communication modules are recommended to support debugging function. If this feature is enabled, debugging logs are recommended to be configured to output through the following data input/output interfaces, including but not limited to UART, USB and SPI.
+
+### **10.3 Minimum AT commands**
+
+In order to ensure the software development compatibility for different universal communication modules, it is recommended to define minimum AT commands, including AT minimum commands for SMS, AT minimum General commands, AT minimum commands for network services, AT minimum commands for mobile termination control and status, AT minimum commands for Mobile termination errors and AT minimum commands for packet domain.
+
+NOTE – 3GPP and ETSI has defined hundreds of AT commands [ETSI TS 127 005] [ETSI TS 127 007] [b-3GPP TS 27.007]. Currently, only a small part of these AT commands is usually implemented, which leads to compatibility problems for software development. It is needed to define minimum AT commands to ensure the software development compatibility for different universal communication modules.
+
+#### 10.3.1 AT minimum commands for SMS
+
+Table 19 lists the recommended AT minimum commands for SMS derived from [ETSI TS 127 005], including the basic functionality of SMS service.
+
+**Table 19 – AT minimum commands for SMS**
+
+| AT commands | Description |
+|-----------------------|------------------------------------------------------------------------------------------------------------|
+| CSMS (Recommended) | Select message service |
+| CMGF (Recommended) | Set command to choose input and output format of messages (protocol data unit (PDU) or text mode) |
+| CSCA (Recommended) | Set command to update the SMS service centre address, through which mobile originated SMS are transmitted. |
+| CMGS (Recommended) | Execution command to send message to the network |
+| CNMI (Recommended) | Set command to select the procedure about how to receive new messages from the network |
+| CNMA (Recommended) | Execution command to confirm correct reception of a new message |
+
+#### 10.3.2 AT minimum general commands
+
+Table 20 lists the recommended AT minimum general commands derived from [ETSI TS 127 007], which are for the identification of universal communication modules.
+
+**Table 20 – AT minimum general commands**
+
+| AT commands | Description |
+|-----------------------|--------------------------------------------------|
+| CGMI (Recommended) | Request manufacturer identification |
+| CGMM (Recommended) | Request model identification |
+| CGMR (Recommended) | Request revision identification |
+| CGSN (Recommended) | Request product serial number identification |
+| CIMI (Recommended) | Request international mobile subscriber identity |
+
+#### 10.3.3 AT minimum commands for Network services
+
+Table 21 the recommended AT minimum commands for network services, derived from [ETSI TS 127 007], and the optional AT minimum commands for Network services, derived from [b-3GPP TS 27.007]. These commands are for NB-IoT/eMTC network service-related commands.
+
+**Table 21 – AT minimum commands for network services**
+
+| AT commands | Description |
+|------------------------|------------------------------------------------|
+| CREG (Recommended) | Network registration |
+| COPS (Recommended) | Public land mobile network (PLMN) selection |
+| CPSMS (Recommended) | Power saving mode setting |
+| CEDRXS (Optional) | Extended idle mode DRX (eDRX) setting |
+| CEDRXRDP (Optional) | eDRX read dynamic parameters |
+| CCIOTOPT (Optional) | Cellular IoT (CIoT) optimization configuration |
+
+#### 10.3.4 AT minimum commands for mobile termination control and status
+
+Table 22 lists the recommended AT minimum commands for mobile termination control and status, derived from [ETSI TS 127 007], and the optional AT minimum commands for mobile termination control and status, derived from [b-3GPP TS 27.007]. These commands are for power, display, indicator handling and setting real time clock facilities.
+
+**Table 22 – AT minimum commands for mobile termination control and status**
+
+| AT commands | Description |
+|-----------------------|-------------------------------------|
+| CFUN (Recommended) | Set phone functionality |
+| CSQ (Recommended) | Signal quality |
+| CCLK (Recommended) | Clock |
+| CLAC (Recommended) | List all available AT commands |
+| CRCES (Optional) | Reading coverage enhancement status |
+
+#### 10.3.5 AT minimum commands for mobile termination errors
+
+Table 23 lists the recommended AT minimum commands for mobile termination errors, derived from [ETSI TS 127 007], which are for an error report.
+
+**Table 23 – AT minimum commands for mobile termination errors**
+
+| AT commands | Description |
+|-----------------------|--------------------------------------|
+| CMEE (Recommended) | Report mobile termination error |
+| CME (Recommended) | Mobile termination error result code |
+
+#### 10.3.6 AT minimum commands for packet domain
+
+Table 24 lists the recommended AT minimum commands for packet domain, derived from [ETSI TS 127 007], and the optional AT minimum commands for packet domain, derived from [b-3GPP TS 27.007]. These commands are used by universal communication modules to support packet switched services.
+
+**Table 24 – AT minimum commands for packet domain**
+
+| AT commands | Description |
+|--------------------------|-----------------------------------------------------|
+| CGDCONT (Recommended) | Define PDP context |
+| CGATT (Recommended) | PS attach or detach |
+| CGPADDR (Recommended) | Show PDP address |
+| CEREG (Recommended) | EPS network registration status |
+| CSCON (Recommended) | Signalling connection status |
+| CNMPSD (Recommended) | No more PS data |
+| CSODCP (Optional) | Sending of originating data via the control plane |
+| CRTDCP (Optional) | Reporting of terminating data via the control plane |
+
+## 11 Performance requirements
+
+In order to ensure the quality of universal communication modules, performance requirements for universal communication modules are identified for the following aspects: storage and temperature.
+
+### 11.1 Storage
+
+To satisfy the communication requirements between universal communication modules and IoT platforms, the modules are recommended to reserve free space in the main chipset for IoT software development kit (SDK). The amount of free space depends on the size of the IoT SDK.
+
+### 11.2 Temperature
+
+In order to meet the different service requirements, universal communication modules are required to adapt to the proper operating and storage temperature range requirements.
+
+## Appendix I
+
+## Use cases for universal communication module of mobile IoT devices
+
+(This appendix does not form an integral part of this Recommendation.)
+
+This appendix provides some use cases for universal communication module of mobile IoT devices.
+
+### I.1 Smart utility metering
+
+
+
+Y.4210(20)\_F1.1
+
+Figure I.1: Smart utility metering design with universal communication module. The diagram shows a central 'Universal communication module' (a green PCB with a QR code and text: SN:2168003819300099, IMEI: 862485030634933) connected to a 'Sensor' via a 'Data input/Output' interface. The module is also connected to an 'MCU' via a 'Module control and status interface' (red double-headed arrow) and a 'UART interface' (blue double-headed arrow). A 'SIM/USIM card' is connected to the module via a 'SIM/USIM interface'. The module communicates wirelessly with a 'Smart utility metering application server' via an 'RF interface' (antenna symbol).
+
+**Figure I.1 – Smart utility metering design with universal communication module**
+
+Smart utility metering devices (including but not limited to gas/heat metering, water metering, electricity metering) may use a universal communication module as shown in Figure I.1. On one hand, the MCU in a smart utility metering device controls the universal communication module by the module control and status interface, and, on the other hand, it collects data from sensors and uses the universal communication module by the UART interface to send data to a smart utility metering application server. The SIM/USIM card and antenna of the universal communication module ensure the data can be sent successfully. In order to support long-term metering, adequate space is needed in the smart utility metering device for large capacity battery; therefore, a small size universal communication module is preferred to ensure sufficient space for the battery.
+
+### I.2 Smart home
+
+
+
+Y.4210(20)\_F1.2
+
+Figure I.2: Smart home design with universal communication module. The diagram shows a central 'Universal communication module' (a green PCB with a QR code and text: SN:2168003819300099, IMEI: 862485030634933) connected to a 'Sensor' via an 'I2C/UART interface'. A 'SIM/USIM card' is connected to the module via a 'SIM/USIM interface'. The module communicates wirelessly with a 'Smart home application server' via an 'RF interface' (antenna symbol).
+
+**Figure I.2 – Smart home design with universal communication module**
+
+Smart home devices (including but not limited to washer, air conditioner and refrigerator) may use a universal communication module as shown in Figure I.2. Universal communication module can collect the data from sensors by I2C/UART interface and send data to a smart home application server. In order to ensure the data can be sent successfully, SIM/USIM card and antenna are needed. Because smart home devices usually have external electric power supply, battery is not a must; therefore, a normal size universal communication module is a good choice.
+
+## Appendix II
+
+## Universal communication module reference types
+
+(This appendix does not form an integral part of this Recommendation.)
+
+Appendices II.1 and II.2 describe the universal communication module reference types which are used for the small size universal communication module.
+
+Appendices II.3 and II.4 describe the universal communication module reference types which are used for the normal size universal communication module.
+
+### II.1 Universal communication module reference Type 1
+
+Universal communication module reference Type 1 is recommended to use LCC package, the length is recommended to be 18mm, and the width is recommended to be 16mm. The pad size and spacing for this type are shown in Figure II.1. All measurements are specified in millimeters. The pad assignments for this type are described in Table II.1.
+
+
+
+Figure II.1: Top view diagram of a 40-pin LCC package showing pad size and spacing. The package is 18mm long and 16mm wide. Pads are numbered 1 to 40. Dimensions include 2.25mm for the top and bottom pad spacing, 1.50mm for the left pad spacing, 1.25mm for the right pad spacing, 0.90mm for the distance between pads 7 and 8, and 0.50mm for the distance between pads 37 and 38. The diagram is labeled 'Top view' and 'Y.4210(20)\_FIL.1'.
+
+Figure II.1 – Pad size and spacing for universal communication module reference Type 1
+
+Table II.1 – Pad assignments for universal communication module reference Type 1
+
+| Pad No. | Pad name | Pad description |
+|---------|-----------|----------------------------------|
+| 1 | UART2_TXD | TXD for the 2 nd UART |
+| 2 | UART2_RXD | RXD for the 2 nd UART |
+| 3 | SPI_SS | SS for SPI |
+| 4 | SPI_MISO | MISO for SPI |
+| 5 | SPI_MOSI | MOSI for SPI |
+| 6 | SPI_SCLK | SCLK for SPI |
+| 7 | UART1_CTS | CTS for the 1 st UART |
+| 8 | UART1_RTS | RTS for the 1 st UART |
+
+**Table II.1 – Pad assignments for universal communication module reference Type 1**
+
+| Pad No. | Pad name | Pad description |
+|---------|--------------|-----------------------------------|
+| 9 | UART1_TXD | TXD for the 1 st UART |
+| 10 | UART1_RXD | RXD for the 1 st UART |
+| 11 | USIM_DETECT | DETECT for USIM |
+| 12 | USIM_RESET | RESET for USIM |
+| 13 | USIM_CLK | CLK for USIM |
+| 14 | USIM_DATA | DATA for USIM |
+| 15 | USIM_VCC | Power supply for USIM |
+| 16 | WAKEUP_OUT | Module wakes up host |
+| 17 | RESET | Reset |
+| 18 | WAKEUP_IN | Host wakes up module |
+| 19 | POWER_ON/OFF | Power on/off |
+| 20 | VDD | Reference logic level from module |
+| 21 | SYS_STATE | Module status indication |
+| 22 | GND | Ground |
+| 23 | GND | Ground |
+| 24 | GNSS_ANT | GNSS antenna |
+| 25 | GND | Ground |
+| 26 | GND | Ground |
+| 27 | ANT0 | Antenna |
+| 28 | GND | Ground |
+| 29 | GND | Ground |
+| 30 | GND | Ground |
+| 31 | VCC1 | Power supply |
+| 32 | VCC2 | Power supply |
+| 33 | RTC Power | Power supply for RTC |
+| 34 | GPIO | General purpose Input/Output |
+| 35 | GPIO | General purpose Input/Output |
+| 36 | I2C_SCL | SCL for I 2 C |
+| 37 | I2C_SDA | SDA for I 2 C |
+| 38 | ADC | Analogue-to-Digital Converter |
+| 39 | RESERVED | To Be Determined (TBD) |
+| 40 | RESERVED | TBD |
+
+### II.2 Universal communication module reference Type 2
+
+Universal communication module reference Type 2 is recommended to use LCC package, the length is recommended to be 20mm, and the width is recommended to be 16mm. The pad size and spacing for this type are shown in Figure II.2. All measurements are specified in millimeters. The pad assignments for this type are described in Table II.2.
+
+
+
+Top view diagram of a 40-pin universal communication module connector. The pins are numbered 1 to 40. Dimensions are specified: 3.25mm for the pitch between pins 1 and 11, and between pins 20 and 30; 1.50mm for the total width; 1.25mm for the distance from the edge to pin 1 and pin 40; 0.90mm for the distance between pins 6 and 7; and 0.50mm for the distance between pins 36 and 37. The text 'Top view' is centered, and 'Y.4210(20)\_FII.2' is at the bottom right.
+
+**Figure II.2 – Pad size and spacing for universal communication module reference Type 2**
+
+**Table II.2 – Pad assignments for universal communication module reference Type 2**
+
+| Pad No. | Pad name | Pad description |
+|---------|--------------|-----------------------------------|
+| 1 | UART2_TXD | TXD for the 2 nd UART |
+| 2 | UART2_RXD | RXD for the 2 nd UART |
+| 3 | SPI_SS | SS for SPI |
+| 4 | SPI_MISO | MISO for SPI |
+| 5 | SPI_MOSI | MOSI for SPI |
+| 6 | SPI_SCLK | SCLK for SPI |
+| 7 | UART1_CTS | CTS for the 1 st UART |
+| 8 | UART1_RTS | RTS for the 1 st UART |
+| 9 | UART1_TXD | TXD for the 1 st UART |
+| 10 | UART1_RXD | RXD for the 1 st UART |
+| 11 | USIM_DETECT | DETECT for USIM |
+| 12 | USIM_RESET | RESET for USIM |
+| 13 | USIM_CLK | CLK for USIM |
+| 14 | USIM_DATA | DATA for USIM |
+| 15 | USIM_VCC | Power supply for USIM |
+| 16 | USIM_GND | Ground for USIM |
+| 17 | WAKEUP_OUT | Module wakes up host |
+| 18 | RESET | Reset |
+| 19 | WAKEUP_IN | Host wakes up module |
+| 20 | POWER_ON/OFF | Power on/off |
+| 21 | VDD | Reference logic level from module |
+| 22 | SYS_STATE | Module status indication |
+| 23 | GND | Ground |
+
+**Table II.2 – Pad assignments for universal communication module reference Type 2**
+
+| Pad No. | Pad name | Pad description |
+|---------|-----------|-------------------------------|
+| 24 | GNSS_ANT | GNSS antenna |
+| 25 | GND | Ground |
+| 26 | GND | Ground |
+| 27 | ANT0 | Antenna |
+| 28 | GND | Ground |
+| 29 | GND | Ground |
+| 30 | GND | Ground |
+| 31 | VCC1 | Power supply |
+| 32 | VCC2 | Power supply |
+| 33 | RTC Power | Power supply for RTC |
+| 34 | GPIO | General purpose Input/Output |
+| 35 | GPIO | General purpose Input/Output |
+| 36 | I2C_SCL | SCL for I 2 C |
+| 37 | I2C_SDA | SDA for I 2 C |
+| 38 | ADC | Analogue-to-Digital Converter |
+| 39 | RESERVED | TBD |
+| 40 | RESERVED | TBD |
+
+### **II.3 Universal communication module reference Type 3**
+
+Universal communication module reference Type 3 is recommended to use LCC package, the length is recommended to be 24 mm, and the width is recommended to be 20 mm. The pad size and spacing for this type are shown in Figure II.3. All measurements are specified in millimetres. The pad assignments for this type are described in Table II.3.
+
+
+
+Top view
+
+Y.4210(20)\_FII.3
+
+Top view diagram of a 52-pin universal communication module reference Type 3. The module is rectangular with pins numbered 1 to 52. Pins 1-13 are on the right side, pins 14-26 are on the top side, pins 27-40 are on the left side, and pins 41-52 are on the bottom side. Dimensions are specified: 3.60 mm for the top and bottom widths, 4.52 mm for the right side height, and 4.50 mm for the bottom side height. Pin spacing is 0.40 mm. Pin 1 is at the bottom right corner. The diagram is labeled 'Top view' and 'Y.4210(20)\_FII.3'.
+
+**Figure II.3 – Pad size and spacing for universal communication module reference Type 3**
+
+**Table II.3 – Pad assignments for universal communication module reference Type 3**
+
+| Pad No. | Pad name | Pad description |
+|---------|------------|----------------------------------|
+| 1 | UART1_TXD | TXD for the 1 st UART |
+| 2 | UART1_RXD | RXD for the 1 st UART |
+| 3 | UART1_CTS | CTS for the 1 st UART |
+| 4 | UART1_RTS | RTS for the 1 st UART |
+| 5 | SPI_SS | SS for SPI |
+| 6 | SPI_MISO | MISO for SPI |
+| 7 | SPI_MOSI | MOSI for SPI |
+| 8 | SPI_SCLK | SCLK for SPI |
+| 9 | USIM_VCC | Power supply for USIM |
+| 10 | USIM_RESET | RESET for USIM |
+| 11 | USIM_DATA | DATA for USIM |
+| 12 | USIM_CLK | CLK for USIM |
+| 13 | USIM_GND | Ground for USIM |
+
+**Table II.3 – Pad assignments for universal communication module reference Type 3**
+
+| Pad No. | Pad name | Pad description |
+|----------------|-----------------|-----------------------------------|
+| 14 | USIM_DETECT | DETECT for USIM |
+| 15 | RTC Power | Power supply for RTC |
+| 16 | VCC1 | Power supply |
+| 17 | VCC2 | Power supply |
+| 18 | GND | Ground |
+| 19 | GND | Ground |
+| 20 | GND | Ground |
+| 21 | GND | Ground |
+| 22 | GNSS_ANT | GNSS antenna |
+| 23 | GND | Ground |
+| 24 | GND | Ground |
+| 25 | ANT0 | Antenna |
+| 26 | GND | Ground |
+| 27 | USB_Dp | USB data (positive) |
+| 28 | USB_Dn | USB data (negative) |
+| 29 | VBUS | USB detect |
+| 30 | GND | Ground |
+| 31 | ADC | Analogue-to-Digital Converter |
+| 32 | GND | Ground |
+| 33 | GPIO | General purpose Input/Output |
+| 34 | GPIO | General purpose Input/Output |
+| 35 | GPIO | General purpose Input/Output |
+| 36 | GPIO | General purpose Input/Output |
+| 37 | WAKEUP_OUT | Module wakes up host |
+| 38 | RESET | Reset |
+| 39 | WAKEUP_IN | Host wakes up module |
+| 40 | POWER_ON/OFF | Power on/off |
+| 41 | VDD | Reference logic level from module |
+| 42 | SYS_STATE | Module status indication |
+| 43 | UART2_TXD | TXD for the 2 nd UART |
+| 44 | UART2_RXD | RXD for the 2 nd UART |
+| 45 | I2C_SCL | SCL for I 2 C |
+| 46 | I2C_SDA | SDA for I 2 C |
+| 47 | RESERVED | TBD |
+| 48 | RESERVED | TBD |
+| 49 | RESERVED | TBD |
+| 50 | RESERVED | TBD |
+| 51 | RESERVED | TBD |
+| 52 | RESERVED | TBD |
+
+### II.4 Universal communication module reference Type 4
+
+Universal communication module reference Type 4 is recommended to use LCC package, the length is recommended to be 26 mm, and the width is recommended to be 24 mm. The pad size and spacing for this type are shown in Figure II.4. All measurements are specified in millimeters. The pad assignments for this type are described in Table II.4.
+
+
+
+The diagram shows the top view of a 68-pin LCC package. The pins are arranged in four rows: 19 pins on the top, 18 pins on the right, 13 pins on the bottom, and 18 pins on the left. The pins are numbered 1 through 68. Dimensions are specified as follows: the overall length is 26 mm (indicated by a 3.40 mm segment at the top right), the overall width is 24 mm (indicated by a 3.30 mm segment on the left), the pitch between pins is 0.40 mm, and the distance from the package edge to the first pin is 0.70 mm. The text 'Top view' is centered in the diagram. The reference 'Y.4210(20)\_FII.4' is located at the bottom right.
+
+Top view diagram of a 68-pin LCC package showing pad numbering and dimensions.
+
+Figure II.4 – Pad size and spacing for universal communication module reference Type 4
+
+Table II.4 – Pad assignments for universal communication module reference Type 4
+
+| Pad No. | Pad name | Pad description |
+|---------|-----------|----------------------------------|
+| 1 | UART1_TXD | TXD for the 1 st UART |
+| 2 | UART1_RXD | RXD for the 1 st UART |
+| 3 | UART1_CTS | CTS for the 1 st UART |
+| 4 | UART1_RTS | RTS for the 1 st UART |
+| 5 | SPI_SS | SS for SPI |
+
+**Table II.4 – Pad assignments for universal communication module reference Type 4**
+
+| Pad No. | Pad name | Pad description |
+|----------------|-----------------|------------------------|
+| 6 | SPI_MISO | MISO for SPI |
+| 7 | SPI_MOSI | MOSI for SPI |
+| 8 | SPI_SCLK | SCLK for SPI |
+| 9 | USIM_VCC | Power supply for USIM |
+| 10 | USIM_RESET | RESET for USIM |
+| 11 | USIM_DATA | DATA for USIM |
+| 12 | USIM_CLK | CLK for USIM |
+| 13 | USIM_GND | Ground for USIM |
+| 14 | USIM_DETECT | DETECT for USIM |
+| 15 | RESERVED | TBD |
+| 16 | RESERVED | TBD |
+| 17 | RESERVED | TBD |
+| 18 | RESERVED | TBD |
+| 19 | RTC Power | Power supply for RTC |
+| 20 | VCC1 | Power supply |
+| 21 | VCC2 | Power supply |
+| 22 | GND | Ground |
+| 23 | GND | Ground |
+| 24 | GND | Ground |
+| 25 | GND | Ground |
+| 26 | GNSS_ANT | GNSS antenna |
+| 27 | GND | Ground |
+| 28 | GND | Ground |
+| 29 | GND | Ground |
+| 30 | ANT0 | Antenna |
+| 31 | GND | Ground |
+| 32 | GND | Ground |
+| 33 | GND | Ground |
+| 34 | GND | Ground |
+| 35 | RESERVED | TBD |
+| 36 | RESERVED | TBD |
+| 37 | RESERVED | TBD |
+| 38 | RESERVED | TBD |
+| 39 | RESERVED | TBD |
+| 40 | RESERVED | TBD |
+| 41 | USB_Dp | USB data (positive) |
+| 42 | USB_Dn | USB data (negative) |
+| 43 | VBUS | USB detect |
+| 44 | GND | Ground |
+
+**Table II.4 – Pad assignments for universal communication module reference Type 4**
+
+| Pad No. | Pad name | Pad description |
+|----------------|------------------------|-----------------------------------|
+| 45 | ADC | Analogue-to-Digital Converter |
+| 46 | GND | Ground |
+| 47 | GPIO | General purpose Input/Output |
+| 48 | GPIO | General purpose Input/Output |
+| 49 | GPIO | General purpose Input/Output |
+| 50 | GPIO | General purpose Input/Output |
+| 51 | GPIO | General purpose Input/Output |
+| 52 | GPIO | General purpose Input/Output |
+| 53 | WAKEUP_OUT | Module wakes up host |
+| 54 | RESET | Reset |
+| 55 | WAKEUP_IN | Host wakes up module |
+| 56 | POWER_ON/OFF | Power on/off |
+| 57 | VDD | Reference logic level from module |
+| 58 | SYS_STATE | Module status indication |
+| 59 | UART2_TXD | TXD for the 2 nd UART |
+| 60 | UART2_RXD | RXD for the 2 nd UART |
+| 61 | I2C_SCL | SCL for I 2 C |
+| 62 | I2C_SDA | SDA for I 2 C |
+| 63 | PCM_SYNC/I2S_WS/GPIO | Digital Audio signal |
+| 64 | PCM_DIN/I2S_DIN/GPIO | Digital Audio signal |
+| 65 | PCM_DOUT/I2S_DOUT/GPIO | Digital Audio signal |
+| 66 | PCM_CLK/I2S_CLK/GPIO | Digital Audio signal |
+| 67 | UART3_TXD | TXD for the 3 rd UART |
+| 68 | UART3_RXD | RXD for the 3 rd UART |
+
+## Bibliography
+
+- [b-ITU-T Y.2091] Recommendation ITU-T Y.2091 (2011), *Terms and definitions for next generation networks*.
+- [b-ITU-T Y.2060] Recommendation ITU-T Y.4000/Y.2060 (2012), *Overview of Internet of things*.
+- [b-ITU-R M.1224-1] Recommendation ITU-R M.1224-1 (03/2012), *Vocabulary of terms for International Mobile Telecommunications (IMT)*.
+- [b-ETSI TS 102 671] ETSI TS 102 671 V9.2.0 (2015-06), *Smart Cards; Machine to Machine UICC; Physical and logical characteristics (Release 9)*
+- [b-GSMA TS.34] GSMA TS.34, *IoT Device Connection Efficiency Guidelines Version 5.0 08 January 2018*.
+- [b-GSMA-Module]
+- [b-3GPP TS 05.01] Recommendation 3GPP TS 05.01 V8.9.0 (2004-11), *Technical Specification Group GSM/EDGE Radio Access Network; Physical layer on the radio path; General description (Release 1999)*.
+- [b-3GPP TS 23.040] Recommendation 3GPP TS 23.040 V14.0.0 (2017-03), *Technical realization of the Short Message Service (SMS) (Release 14)*.
+- [b-3GPP TS 23.401] Recommendation 3GPP TS 23.401 V14.2.0 (2016-12), *General Packet Radio Service (GPRS) enhancements for Evolved Universal Terrestrial Radio Access Network (E-UTRAN) access (Release 14)*.
+- [b-3GPP TS 23.682] Recommendation 3GPP TS 23.682 V14.8.0 (2018-06), *Architecture enhancements to facilitate communications with packet data networks and applications (Release 14)*.
+- [b-3GPP TS 27.007] Recommendation 3GPP TS 27.007 V14.6.0 (2017-12), *AT command set for User Equipment (UE) (Release 14)*.
+- [b-3GPP TS 36.300] Recommendation 3GPP TS 36.300 V14.7.0 (2018-06), *Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Overall description; Stage 2 (Release 14)*.
+- [b-Information Electrical-Interface-1] Apress, Berkeley, CA (2016) *Samsung ARTIK Reference*, ISBN 978-1-4842-2321-5.
+- [b-Information Electrical-Interface-2] Apress, Berkeley, CA (2018) *Advanced Raspberry Pi*, ISBN 978-1-4842-3947-6
+- [b-Information Package-1] Springer (1993), *Structural Analysis of Printed Circuit Board Systems*, ISBN 978-1-4612-6945-8.
+- [b-Information Package-2] Kluwer Academic Publishers (2001), *Area Array Interconnection Handbook*, ISBN 978-1-4613-5529-8.
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.4213-202111-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..94d45ee0d7450a0c276bffad33306ce1ec96de62
--- /dev/null
+++ b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/14a22f23ced8ba1d63ece69861dbaacc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c981deef08fa0ff69264e0a06c61f5dd291a362fb37303b3216e33a0ba5040e9
+size 5841
diff --git a/marked/Y/T-REC-Y.4213-202111-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..31acffeaab18b65147ddc56d00e8e6061815aa3c
--- /dev/null
+++ b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:03c8d88e5f43d8b8f64c65aeac31a977d4a92cc4af53cd4bcb8eeb45e2b74b8e
+size 34910
diff --git a/marked/Y/T-REC-Y.4213-202111-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3a6dbed463f2a5abe545fbb78446f64d2d4910a6
--- /dev/null
+++ b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1be41da3ff98f0cc21e18078a7211bbd51e0c39600163c70a1c6925504a5701e
+size 114287
diff --git a/marked/Y/T-REC-Y.4213-202111-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e735395d4f4c6426356bb61c19e49a153c5eaa97
--- /dev/null
+++ b/marked/Y/T-REC-Y.4213-202111-I_PDF-E/fc69ceb1dee1da7e33bd6c38fc4ceab9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:1f4625b80e1bcd70c8664e2c75d5276754df8f828ede750c18609d7163d0c860
+size 68028
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..f09f7c89de6da623f0703f8b0c4b8144f3fe0a6c
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/1b5a812c8aa20fd5cba28e97001d32de_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:671ef78a7d296160e11aeb86dc1e74c450e99dddad86600af14b8932eed9c1b0
+size 99250
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..417326c8a9b14495f2a77d99d90673092187d0a8
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/5b8a756d9a71c35f17db8bcb90b438a3_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3dc1cd79be53804bb68720df1dd6c4a952298ca71f483a4463089a801fd79755
+size 26991
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d141788b07c7aef26cdaad86f37325ace9a37586
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/7133ccf78043568ca62ecbcd43628a4a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:84666e1647c7d8dd3886e1bea76b0e561dced98480d4fcfcb11ef515b1d48184
+size 99611
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c9a2446b2b239106cb9e7f0d1f29743f3d390919
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/af7916c89a458fdab6c3f443217388ae_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:f7e35fa7cacb9aeb9e7a1edf25e9efc37eb9b7d14fea1ed687132dfa43889bdb
+size 104616
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ec34f203a8e3014c8b1671e709dd9dd00a551b0d
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/b8661c6c54f72ecc7ff6cb05e47b2891_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e452f43bc1827eef41cc9c441b1318a893879cb30b3cf5d1faa8dbbcda14b96c
+size 103596
diff --git a/marked/Y/T-REC-Y.4218-202305-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3eca4cd49a2cc72894f85780693f7782e7252309
--- /dev/null
+++ b/marked/Y/T-REC-Y.4218-202305-I_PDF-E/e69b9188aa2c14ec6b21c83f711fef65_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0526f1efca3b971f8cdd56b469c24b09ce6287ae4f9c497692d46760f71db98c
+size 103950
diff --git a/marked/Y/T-REC-Y.4220-202303-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.4220-202303-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..71833e40f07805215e2ceeed4f37dc2385ef2b80
--- /dev/null
+++ b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/75f0cb39f1cd165dfe4a6aa6c4d9388d_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2a45dbf33ef24cabbdda05da87dc352718291ca3b9a46c2696a220f4d99c2cfe
+size 33188
diff --git a/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..265aa51db3b8acbfb5f9bce626f175271d26e8ab
--- /dev/null
+++ b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7a0db9703b68b3d06cdaeefc084c0006_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:db1a63c471c13709c64d81338a92012953592feed69eed7b60d0f06976e7697c
+size 42036
diff --git a/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a47ebd4067fedb56193e9d1df5a047d26285f10e
--- /dev/null
+++ b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/7c6d9bfe9c31ce872722d60b73d20df1_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:3e013bf8744673b0ffcff41accb1f347efceb39b192dffc8aa9ba7c6dfd01ca7
+size 98638
diff --git a/marked/Y/T-REC-Y.4220-202303-I_PDF-E/c036e2540a94b31357ceb0002f0cacab_img.jpg b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/c036e2540a94b31357ceb0002f0cacab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2023a20de3bf70812cc10a9fdbc54e3e856a72ec
--- /dev/null
+++ b/marked/Y/T-REC-Y.4220-202303-I_PDF-E/c036e2540a94b31357ceb0002f0cacab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:9c546c1068d22cfd653ad431d64f5953967781bcc944dd3e6412ec274aa22cfa
+size 30568
diff --git a/marked/Y/T-REC-Y.4223-202309-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.4223-202309-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..a30e1cf66cba21185f1f6e478011b0f0db92e358
--- /dev/null
+++ b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/b3baf3a29b67c7425d2562ddbc52f0cc_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:73a8b3a716aa928c316dd4ba3c4edad6378e7b7cdf50bc3acf6ad98b078070a2
+size 42035
diff --git a/marked/Y/T-REC-Y.4223-202309-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9dcb509577ade020a58b2e27320c100fcc686dc8
--- /dev/null
+++ b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/cab0834804fb031b43865554cc8d06ab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:6d6ce13df9bae09c65676fdd5abc22e7374c1095f48b25548a7e12e5e68de445
+size 90099
diff --git a/marked/Y/T-REC-Y.4223-202309-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..413ef689624e13ee8bb99cf1a183c3a34abd4b18
--- /dev/null
+++ b/marked/Y/T-REC-Y.4223-202309-I_PDF-E/dbe553cf16dd14073b89a8263a428664_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:0710898039f4f2d691ef233beca98bd9a1514e2a75e7ef759e2c14b06b05644d
+size 43191
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/3f1987804d7d78bc3b3bc560e974280a_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/3f1987804d7d78bc3b3bc560e974280a_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..2bfa28ae6cf4b49066c329acdcbbff0f18989217
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/3f1987804d7d78bc3b3bc560e974280a_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:be909961526e85b3693f1e30710cf6404cb114e0b0b18b161928279efab5556c
+size 37686
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..31eccc6bebda033f3944b2247a61c64504f5222f
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/4801720824e4b5e2361a5564f91cfb70_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:e14920ad9818dc925d5382c49ace07c8e2be21902b6d58c35d0796640118d6c5
+size 74602
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..cd733ebd431ded0cf87c73cf13e102f9ccd7a590
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/7e670a2b556b53ea9002dfff3a420e08_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:04564da05b68ce535c9f7fc1f43855a418e10e89b3d7547659b88c88f8989eb8
+size 25693
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..520fc3ebf0538f338d4d9a4894e05c31011cf5c5
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/853f59c89931a666c07903b31d098277_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:38cacbc9e60d8a84f4b0b14a4a25706930de9520784729c2c3e65f62445bbf18
+size 44530
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..ea1a2f9c3c8c30bcf4eff4b3a5efeab1162b6773
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a26e142d3df5bef41a84a9dd099d7825_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5163bd9511093279d4e33023e2f8e943daf1d246e5e6dad9bb145c28da2fd59b
+size 49478
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..e19c830d2126dcc1db678c74633fd38d874c5b98
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a5ee5c23b6dc52ec1d724b76d5a5f58f_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:5ea61d4522958bf9cf2b128e61ade7561a0d270735eca81bec3c50b6397e8407
+size 108537
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4cf57b24cfbaf2d6481bbd3a25ac88abd1d9018f
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:abbd08bee18062a05e3ffd7efdf31a5d5886740971bbfc1eca0e735acb66a1f8
+size 47571
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0b484b8bc81e878b0d782bbece481878f236a338
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/bd0b93e7a46ede276d0a3b79ac487bd9_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:d23c3fbd4ab83685306b0227fefe1c643dcb6a7a9537804b54aa033dcdbe9063
+size 37379
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..9cc12ca9f5ce25805a73641bfda9ed9ef46735ac
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/c78c2eefd86269d1740ab85a916f24f2_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4792ecebddb25bac97c74f7a56464f6ef68d1b7ff244b1ccbbd274e4b155ab8f
+size 50175
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..7751edfc72e61f4fa55c8005972814aae6fe0efb
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ddc7460821484f1ae2835c67955c554c_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:504e34784edeba29691687c5026d23d3844ad7b46548774fefddc2e6f8f4ebf9
+size 14475
diff --git a/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c930543633ebe65e1665ea9c84d388b034e1b42a
--- /dev/null
+++ b/marked/Y/T-REC-Y.4227-202408-I_PDF-E/ff0952ef692c9d960ce5f6708bcc9711_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:72aca097313aa8809def0b924b0bcbc5d4ef033b79c3a31f644d26063dfc5c8e
+size 28334
diff --git a/marked/Y/T-REC-Y.4228-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..0370cca94548bc5ba63f48aff76b926d2b626f74
--- /dev/null
+++ b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cdc931c60f5a6858102c29af12b5da379cdd8dd49be11a42d5617986c2afc741
+size 7140
diff --git a/marked/Y/T-REC-Y.4228-202408-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..1db799c18f90afc67b66a7dd3c851169fee3fc90
--- /dev/null
+++ b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/cbdfdade780e677eb1c1aef3081ce9ef_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:cf401cf94279ccff87d03cf6fd64283c0692ac034dc0d348d160831d55056e13
+size 199124
diff --git a/marked/Y/T-REC-Y.4228-202408-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..93e229cff8deb4e78aed81f1af1755162ea1b87b
--- /dev/null
+++ b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/d4af765160d04ecef538e5066006dc77_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:b194e378b90329dfcf33711e9c74b061b6c3ac052e0048345562a9176c693c0a
+size 154898
diff --git a/marked/Y/T-REC-Y.4228-202408-I_PDF-E/raw.md b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..cbe53a4d3c7f30866221204da48a25f75f73d1a8
--- /dev/null
+++ b/marked/Y/T-REC-Y.4228-202408-I_PDF-E/raw.md
@@ -0,0 +1,1168 @@
+
+
+# Recommendation
+
+# **ITU-T Y.4228 (08/2024)**
+
+SERIES Y: Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+Internet of things and smart cities and communities –
+Requirements and use cases
+
+---
+
+# **Requirements and framework of industrial IoT (IIoT) infrastructure for smart manufacturing**
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+| | |
+|---------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | Y.100-Y.999 |
+| INTERNET PROTOCOL ASPECTS | Y.1000-Y.1999 |
+| NEXT GENERATION NETWORKS | Y.2000-Y.2999 |
+| FUTURE NETWORKS | Y.3000-Y.3499 |
+| CLOUD COMPUTING | Y.3500-Y.3599 |
+| BIG DATA | Y.3600-Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800-Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | Y.4000-Y.4999 |
+| General | Y.4000-Y.4049 |
+| Definitions and terminologies | Y.4050-Y.4099 |
+| Requirements and use cases | Y.4100-Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250-Y.4399 |
+| Frameworks, architectures and protocols | Y.4400-Y.4549 |
+| Services, applications, computation and data processing | Y.4550-Y.4699 |
+| Management, control and performance | Y.4700-Y.4799 |
+| Identification and security | Y.4800-Y.4899 |
+| Evaluation and assessment | Y.4900-Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.4228
+
+# Requirements and framework of industrial IoT (IIoT) infrastructure for smart manufacturing
+
+## Summary
+
+Recommendation ITU-T Y.4228 provides requirements and reference framework of the industrial Internet of things (IIoT) infrastructure capabilities for smart manufacturing to help service providers implement their system according to the needs of smart manufacturing and merge existing and newly developed IIoT infrastructure, in order to give the stakeholders of smart manufacturing guidance for their applications. Industrial Internet of things (IIoT) infrastructure for smart manufacturing refers to common facilities based on IoT that support smart manufacturing in industries or sectors. It is independent of the products and production process in specific enterprises.
+
+## History\*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T Y.4228 | 2024-08-29 | 20 | 11.1002/1000/16053 |
+
+## Keywords
+
+IIoT, industrial Internet of things, infrastructure, smart manufacturing.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2024
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|-----------------------------------------------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 1 |
+| 3.1 Terms defined elsewhere..... | 1 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 5 |
+| 6 Introduction of Industrial Internet of things infrastructure..... | 5 |
+| 6.1 Device layer..... | 6 |
+| 6.2 Network layer ..... | 7 |
+| 6.3 Service support and application support layer..... | 10 |
+| 6.4 Industrial SDN..... | 10 |
+| 6.5 Identification facilities..... | 11 |
+| 6.6 Security and information protection facilities ..... | 11 |
+| 7 Common characteristics and requirements of IIoT infrastructure for smart manufacturing..... | 12 |
+| 7.1 Common characteristics ..... | 12 |
+| 7.2 High-level requirements ..... | 14 |
+| 7.3 Layer level requirements ..... | 16 |
+| 8 Reference framework of the IIoT infrastructure capabilities for smart manufacturing..... | 19 |
+| 8.1 Reference framework ..... | 19 |
+| 8.2 Details on the capabilities..... | 22 |
+| 9 Security considerations..... | 29 |
+| Bibliography..... | 30 |
+
+
+
+# Recommendation ITU-T Y.4228
+
+## Requirements and framework of industrial IoT (IIoT) infrastructure for smart manufacturing
+
+# 1 Scope
+
+This Recommendation introduces the concept of industrial Internet of things (IIoT) infrastructure for smart manufacturing (SM), analyses its requirements, and provides a reference framework of the IIoT infrastructure capabilities for smart manufacturing.
+
+The scope of this Recommendation includes:
+
+- concept, common characteristics, and requirements of IIoT infrastructure;
+- reference framework of the IIoT infrastructure capabilities for smart manufacturing.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|----------------|----------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T Y.4000] | Recommendation ITU-T Y.4000/Y.2060 (2012), Overview of the Internet of things . |
+| [ITU-T Y.4003] | Recommendation ITU-T Y.4003 (2018), Overview of smart manufacturing in the context of the industrial Internet of things . |
+| [ITU-T Y.4100] | Recommendation ITU-T Y.4100/Y.2066 (2014), Common requirements of the Internet of things . |
+| [ITU-T Y.4401] | Recommendation ITU-T Y.4401/Y.2068 (2015), Functional framework and capabilities of the Internet of things . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 factory external network** [b-ITU-T Y.2623]: A network aiming to support various activities during the whole industrial life cycle and is used to connect the upstream and downstream of an enterprise, enterprise and intelligent products, as well as enterprise and users.
+
+**3.1.2 factory internal network** [b-ITU-T Y.2623]: A network used for connection between the production factors, and between the corporate information technology (IT) management systems within a factory.
+
+**3.1.3 industrial Internet of things (IIoT)** [ITU-T Y.4003]: An Internet of things based enabling approach for industrial transformation, by taking advantage of existing and emerging information and communication technologies.
+
+NOTE 1 – Emerging information and communication technologies include technologies for smart machines, robots, advanced industrial networks, industrial cloud computing and industrial data processing.
+
+NOTE 2 – The industrial transformation enabled by the industrial Internet of things empowers the industry with, but not limited to, improved efficiency, intelligent production, reduced energy consumption, advanced collaboration modes and new business models. The industrial Internet of things enables smart manufacturing providing enhanced capabilities in support of manufacturing.
+
+**3.1.4 Internet of things (IoT)** [ITU-T Y.4000]: A global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on existing and evolving interoperable information and communication technologies.
+
+NOTE 1 – Through the exploitation of identification, data capture, processing and communication capabilities, the IoT makes full use of things to offer services to all kinds of applications, whilst ensuring that security and privacy requirements are fulfilled.
+
+NOTE 2 – From a broader perspective, the IoT can be perceived as a vision with technological and societal implications.
+
+**3.1.5 smart manufacturing** [ITU-T Y.4003]: A generic term for advanced processes, systems, methods and organizations throughout the manufacturing ecosystem based on advanced computing and manufacturing technologies, as well as existing and evolving interoperable information and communication technologies, aiming to integrate this ecosystem, innovate the development of products and services and improve the efficiency and reliability of manufacturing's life-cycle management, together with increasing performance, safety and environmental sustainability.
+
+NOTE – The concept of smart manufacturing encompasses all aspects of the manufacturing activities, from design, sales, production, logistics and service.
+
+## **3.2 Terms defined in this Recommendation**
+
+None.
+
+# **4 Abbreviations and acronyms**
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|--------|----------------------------------------|
+| 4G | 4 th Generation |
+| 5G | 5 th Generation |
+| ACL | Access Control List |
+| AGV | Automated Guided Vehicle |
+| AI | Artificial Intelligence |
+| API | Application Programming Interface |
+| BGP | Border Gateway Protocol |
+| BGP-LS | Border Gateway Protocol – Link State |
+| CAD | Computer Aided Design |
+| CAE | Computer Aided Engineering |
+| CoAP | Constrained Application Protocol |
+| CRM | Customer Relationship Management |
+| DCS | Distributed Control System |
+| DMZ | Demilitarized Zone |
+| DTLS | Datagram Transport Layer Security |
+| DWDM | Dense Wavelength Division Multiplexing |
+| E2E | End-to-End |
+
+| | |
+|----------|-------------------------------------------------|
+| EDP | Enhanced Device Protocol |
+| ERP | Enterprise Resource Planning |
+| FCS | Fieldbus Control System |
+| Flowspec | Flow Specification |
+| GRE | Generic Routing Encapsulation |
+| HA | High Availability |
+| HMI | Human Machine Interface |
+| HTTP | Hypertext Transfer Protocol |
+| I/O | Input/Output |
+| IaaS | Infrastructure as a Service |
+| ID | Identifier |
+| IIoT | Industrial Internet of Things |
+| IoT | Internet of Things |
+| IP | Internet Protocol |
+| IPS | Invasion Protection System |
+| IPsec | Internet Protocol Security |
+| IPv4 | Internet Protocol version 4 |
+| IPv6 | Internet Protocol version 6 |
+| IT | Information Technology |
+| L2TP | Layer 2 Tunnelling Protocol |
+| MES | Manufacturing Execution System |
+| MPLS | Multiprotocol Label Switching |
+| MQTT | Message Queuing Telemetry Transport |
+| NB-IoT | Narrowband Internet of Things |
+| NETCONF | Network Configuration Protocol |
+| NFV | Network Functions Virtualization |
+| NoSQL | Not only SQL |
+| OA | Office Automation |
+| OAM | Operation, Administration and Maintenance |
+| OID | Object Identifier |
+| ORS | OID Resolution System |
+| OSI | Open Systems Interconnection |
+| OT | Operational Technology |
+| OTN | Optical Transport Network |
+| PaaS | Platform as a Service |
+| PC | Personal Computer |
+| PCEP | Path Computation Element Communication Protocol |
+
+| | |
+|--------|-----------------------------------------------------------------|
+| PDE | Packet Duplication and Elimination |
+| PLC | Programmable Logic Controller |
+| PLM | Product Lifecycle Management |
+| PON | Passive Optical Network |
+| QoS | Quality of Service |
+| R&D | Research and Development |
+| RFID | Radio Frequency Identification |
+| RS | Recommended Standard |
+| SaaS | Software as a Service |
+| SCADA | Supervisory Control and Data Acquisition |
+| SCM | Supply Chain Management |
+| SDH | Synchronous Digital Hierarchy |
+| SDN | Software-Defined Networking |
+| SDO | Standards Development Organization |
+| SD-WAN | Software-Defined Wide Area Network |
+| SLA | Service Level Agreement |
+| SM | Smart Manufacturing |
+| SMPP | Short Message Peer-to-Peer |
+| SNMP | Simple Network Management Protocol |
+| SQL | Structured Query Language |
+| SR | Segment Routing |
+| TCP | Transmission Control Protocol |
+| TLS | Transport Layer Security |
+| TSN | Time-Sensitive Networking |
+| ULSIN | Unified Large Scale Industrial Network |
+| VLAN | Virtual Local Area Network |
+| VPN | Virtual Private Network |
+| VXLAN | Virtual extensible Local Area Network |
+| WIA-FA | Wireless network for Industrial Automation - Factory Automation |
+| WIA-PA | Wireless network for Industrial Automation - Process Automation |
+| Wi-Fi | Wireless Fidelity |
+| WPAN | Wireless Personal Area Network |
+| YANG | Yet Another Next Generation |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this Recommendation is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus this requirement needs not be present to claim conformance.
+
+The keywords "can optionally" and "may" indicate an optional requirement which is permissible, without implying any sense of being recommended. These terms are not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# 6 Introduction of Industrial Internet of things infrastructure
+
+Smart manufacturing provides an advanced production mode based on the deep integration of advanced manufacturing technology and new generation information technology, which runs through the whole product life cycle such as design, production, sales, logistics and services. Smart manufacturing has the characteristics of self-perception, self-decision-making, self-performing, self-adaptation and self-learning, and it aims to improve the quality, efficiency and flexibility of the manufacturing industry.
+
+IIoT infrastructure plays a crucial role in smart manufacturing, and provides supporting smart manufacturing capabilities, as presented in [ITU-T Y.4003]. This clause introduces technical aspects with regard to the IIoT Infrastructure utilized for smart manufacturing.
+
+NOTE – With respect to smart manufacturing, the IIoT constitutes a critical foundation. As an IoT-based enabling approach [ITU-T Y.4003], IIoT is the approach to support smart manufacturing, but the IIoT infrastructure is not specifically dedicated only to the support of smart manufacturing, i.e., other applications or industries can be supported by the IIoT infrastructure. However, there is a strong crossover between "IIoT" and "smart manufacturing" (SM) in terms of public recognition by global advanced manufacturing and IoT engaged standards development organizations (SDOs), organizations and other interested groups [b-ISO/IEC TR 30166].
+
+Figure 1 depicts a conceptual framework of the IIoT infrastructure from the Internet of things (IoT) and smart manufacturing points of view, based on the IoT reference model layering [ITU-T Y.4000]. The following clauses describe the facilities of the three layers, as well as the cross-layer facilities of this framework.
+
+
+
+The diagram illustrates the conceptual framework of IIoT infrastructure, organized into three main layers: Service support and application support layer, Network layer, and Device layer. To the right of these layers are three vertical bars representing Industrial SDN, Identification facilities, and Security and information protection facilities.
+
+- Service support and application support layer:**
+ - Software facilities:** Cloud-based software, program, system, platform, operating system, message broker, message queue, etc. (includes a dashed box labeled Database).
+ - Hardware facilities:** Application server, edge computing node, storage, etc.
+- Network layer:**
+ - Factory external network:** SDH, DWDM, OTN, IP, microwave, etc.
+ - Factory internal network:**
+ - IT network:**
+ - Enterprise level:** IP, Ethernet, Industrial PON for MES, ERP, PLM, CRM, SCM, etc.
+ - OT network:**
+ - Workshop level:** Industrial Ethernet, industrial wireless network for SCADA, HMI, etc.
+ - Field level:** Fieldbus, industrial Ethernet, industrial wireless network for PLC, DCS, FCS, etc.
+- Device layer:**
+ - Sensors and gateways:** Sensor, transducer, actuator, camera, RFID reader, barcode scanner, industrial gateway, PLC, etc.
+
+Y.4228(24)
+
+Figure 1: Conceptual framework of the IIoT infrastructure from the IoT and smart manufacturing points of view. The diagram shows a layered architecture with three main layers: Service support and application support layer, Network layer, and Device layer. The Service support layer includes Software facilities (Cloud-based software, program, system, platform, operating system, message broker, message queue, etc.) and Hardware facilities (Application server, edge computing node, storage, etc.). The Network layer includes Factory external network (SDH, DWDM, OTN, IP, microwave, etc.) and Factory internal network (IT network and OT network). The IT network includes Enterprise level (IP, Ethernet, Industrial PON for MES, ERP, PLM, CRM, SCM, etc.). The OT network includes Workshop level (Industrial Ethernet, industrial wireless network for SCADA, HMI, etc.) and Field level (Fieldbus, industrial Ethernet, industrial wireless network for PLC, DCS, FCS, etc.). The Device layer includes Sensors and gateways (Sensor, transducer, actuator, camera, RFID reader, barcode scanner, industrial gateway, PLC, etc.). To the right of the layers are three vertical bars representing Industrial SDN, Identification facilities, and Security and information protection facilities.
+
+**Figure 1 – Conceptual framework of the IIoT infrastructure from the IoT and smart manufacturing points of view**
+
+## 6.1 Device layer
+
+Due to the many communication technologies in the industrial network, the relevant communication media in the IIoT infrastructure physical layer are very diverse. The devices connected in the industrial network are not only personal computers (PCs), printers and other equipment, but also industrial control and management equipment, such as industrial PCs, human machine interface (HMI), programmable logic controllers (PLCs), motion controllers, remote terminals, and radio frequency identification (RFID) equipment. These devices work at different layers or across multiple layers of the open systems interconnection (OSI) [b-ITU-T X.200] reference model, provide data in standardized or non-standardized format, receive control and adjustment signals from the upper layers, and perform comprehensive sensing and control of relevant hardware and processes in the industrial production environment.
+
+These devices can be distinguished into sensors and gateways, which directly interact with machines, robotics, environment equipment and other field facilities for smart manufacturing production.
+
+### **6.1.1 Sensors**
+
+They belong to different categories, such as sensors of resources, security, presence, lighting, motion, environment and position, and are installed on the physical facilities for smart manufacturing. These devices make it possible to collect and track the status of smart manufacturing machines, operations, environment, etc., in order to help the facilities in the upper layers in gathering, processing, analysing and eventually generating valuable information throughout services for smart manufacturing.
+
+### **6.1.2 Gateways**
+
+The manufacturing-specific gateways connect manufacturing facilities such as sensors, PLCs, machines and robotics which have open data interfaces. This is to sense and identify data upward from different resources and help control and execute decision flows downward from the upper layer facilities. Gateways translate and transform information coming from devices and sensors into formats and structures suitable for applications and systems in the upper layer, and transport them using suitable network protocols, and vice versa.
+
+In the industrial environment, services are not only deployed in the cloud, but also likely to be deployed in both the industrial field and the cloud. The industrial field equipment and machines will produce extensive data at the edge of the network, and the edge network equipment such as gateways at the industrial field will require interoperable data processing capability and flexible service carrying and forwarding capability.
+
+## **6.2 Network layer**
+
+The network provides comprehensive interconnection of people, machines and things, in order to transport data among them, this being a basic function to fulfil the requirements of industrial applications. It promotes seamless flowing and integration of diverse industrial data.
+
+The IIoT network connections involve different technical fields inside and outside the enterprise. Many networking technologies are used in the industrial field with related performance advantages in specific scenarios. However, these technologies with specific capabilities (such as many kinds of industrial fieldbuses) are designed and applied only in specific scenarios, and cannot meet the requirements of IIoT in terms of data interoperability and seamless integration.
+
+The overall goal of the network connectivity is to promote the interconnection between systems, unlock data from isolated systems or networks, and make data play a greater value for industry and cross industry applications.
+
+The network layer consists of two sub-layers, the factory internal network sub-layer and the factory external network sub-layer [b-ITU-T Y.2623].
+
+### **6.2.1 Factory internal network**
+
+The factory internal network is the network inside the factory or the enclosed area for production, which is used to connect smart manufacturing related industrial resources [b-ISO/IEC TR 30166]: personnel (such as production personnel, designers and external personnel), machines (such as production equipment and office devices), materials (such as raw materials, semi-finished and finished products), processes (such as exchange of materials and control of production), environmental assets (such as instruments and monitoring equipment), etc. Through the factory internal network, these resources are interconnected with the enterprise data centre and application servers to support services and applications.
+
+From the smart manufacturing point of view, the factory internal network encompasses an operational technology (OT) network and an information technology (IT) network [b-ITU-T Y.2623].
+
+NOTE 1 – The OT network is a network which supports hardware and software that detects or causes a change through the direct monitoring and/or control of physical devices and systems, processes and events in the organization [b-ISO/IEC TR 23188]. The OT network mainly facilitates smart manufacturing and control, while the IT network mainly aims to connect office systems, mail servers, production management systems, data centres, and more [b-ITU-T Y.2623].
+
+Given the industrial digitalization, to make optimal use of diverse industrial data, these data need to be comprehensively networked, which means interconnecting the OT network with the IT network. The OT network and the IT network are interconnected with each other via industrial gateways (such as firewalls, data-diodes and invasion protection systems (IPSS)) while enabling physical network isolation for security reasons [b-ITU-T Y.2623].
+
+NOTE 2 – A common practice is to have a demilitarized zone (DMZ) between the OT network and the IT network.
+
+The operational technology (OT) network encompasses the field level and the workshop level, while the IT network only relates to the enterprise level. Different levels of the factory internal network can meet the functional requirements of different levels of management and realize effective network management and control [ITU-T Y.4003]. Such multi-level network design promotes efficient support for manufacturing automation, achieving refined management and intelligent decision-making. Meanwhile, the multi-level network also helps establish security isolation between different levels, protecting critical manufacturing data and systems from threats. The manageability, security, and flexibility of the factory internal network can then be improved, in order to better support deep integration of industrial automation and informatization.
+
+- 1) The field level of the OT network is responsible for connecting industrial field equipment. The field level network typically needs high reliability and real-time performances to ensure the continuity and stability of the production processes. The design of the field level network needs to consider the specific communication requirements of the industrial field equipment, such as resistance to electromagnetic interference and adaptability to environmental conditions.
+
+As far as the field level of the OT network, the commonly used communication technologies are industrial fieldbus technologies, industrial Ethernet technologies and industrial wireless networking technologies.
+
+The industrial fieldbus technologies (such as the fieldbus technologies described in IEC 61158-1 [b-IEC 61158-1], recommended standard 232 (RS232) [b-TIA-232] and RS485 [b-TIA-485]) are widely used to connect field detection sensors, actuators and industrial controllers. Industrial fieldbus technologies mainly provide data communication support from field sensors to controllers, controllers to actuators, or between controllers and each input/output (I/O) control substations, such as programmable logic controller (PLC), distributed control system (DCS) and fieldbus control system (FCS).
+
+NOTE 3 – Compared with other communication technologies, the industrial fieldbus technologies face some weaknesses, such as low communication ability, short distance, poor anti-interference ability and others. Their vulnerability to strong current interference, low reliability, obsolete maintenance mode, limitation of bandwidth and distance, and high cost of cable laying causes strong limitations of usage. However, industrial passive optical network (PON) [b-ETSI GR F5G 007] technology can be adopted for the industrial fieldbuses. The industrial PON is based on optical communication technology, combined with capabilities of single or multiple level optical splitting and multiple terminals access via an optical distribution network [b-ETSI GR F5G 007]. The industrial PON technology provides competitive performance for fieldbuses, and, further, it provides higher bandwidth and lower transmission delay than traditional fieldbus technologies.
+
+The industrial Ethernet technologies (such as those based on the real-time Ethernet communication profiles described in [b-IEC 61784-2-3]) are customized and optimized communication technologies for industrial automation. Many industrial Ethernet protocols have gradually entered the control and communication applications in various industrial
+
+control systems. Their high communication performance and flexibility in network topology scale have laid a foundation for the improvement of the industrial field control level.
+
+The industrial wireless networking technologies include wireless fidelity (Wi-Fi) [b-IEEE 802.11], Bluetooth [b-Bluetooth], wireless personal area network (WPAN), wireless network for industrial automation – process automation (WIA-PA) [b-IEC 62601], wireless network for industrial automation – factory automation (WIA-FA) [b-IEC 62948], RFID, narrowband Internet of things (NB-IoT) [b-3GPP TS 36.300], ISA-100.11a [b-ISA-100.11a]. They are mainly used in some non-critical industrial applications, such as applications for material transport, inventory management, patrol inspection, maintenance, and others. They connect mobile equipment in the enterprise where cable connection is difficult or impossible.
+
+NOTE 4 – With the development of the 5th generation (5G), performance indicators such as delay, and reliability may require to be guaranteed for extreme industrial control applications. With the usage of such technologies, the 5G network can enlarge the scale of industrial wireless network applications, and enable full interconnection between the industrial wireless networks and the industrial fixed networks (e.g., industrial Ethernet based network).
+
+- 2) The workshop level of the OT network is responsible for connecting industrial workshop equipment, such as controllers and systems. The workshop level network needs to handle more data and support the coordination and optimization of data within the workshop. The design of the workshop level network needs to consider the integration and flowing of data, as well as the interconnection and interoperability with the upper enterprise level network.
+
+As far as the workshop level of the OT network, the workshop level network communication enables connectivity between controllers, between controllers and local or remote monitoring systems, and between controllers and operation level systems (such as supervisory control and data acquisition (SCADA) [b-SCADA] and HMI [b-ITU-T H.320]). The workshop level mainly adopts industrial Ethernet and industrial wireless networking technologies.
+
+- 3) The enterprise level of the IT network is the top level of the factory internal network. The enterprise level network connects different workshops and enterprise level systems of the entire enterprise. The enterprise level network not only needs to handle a large amount of data and information, but also supports advanced functions such as enterprise decision-making, resources management and strategic planning. The design of the enterprise level network needs to consider the scalability, security and connectivity to other networks.
+
+As far as the enterprise level of the IT network, the commonly used communication technologies for network interconnection among enterprise level systems are high-speed Ethernet [b-IEEE 802.3], transmission control protocol / Internet protocol (TCP/IP) (request for comments (RFC) 1180 [b-IETF RFC 1180]) and industrial PON.
+
+NOTE 5 – The enterprise level systems include manufacturing execution system (MES), enterprise resource planning (ERP), product lifecycle management (PLM), customer relationship management (CRM) and supply chain management (SCM).
+
+### 6.2.2 Factory external network
+
+The factory external network is the network which is used to connect different entities of the smart manufacturing production cycle, including enterprise branches, enterprises and industrial data centres.
+
+NOTE – As an example, the application servers of an industrial data centre inside an enterprise are interconnected with the industrial data centres outside the enterprise through the factory external network. As another example, enterprise branches and enterprises are connected to the industrial data centres inside an enterprise through the factory external network.
+
+The factory external network can adopt different network technologies, including synchronous digital hierarchy (SDH) [b-ITU-T G.803], dense wavelength division multiplexing (DWDM) [b-ITU-T G.671], optical transport network (OTN) [b-ITU-T G.872], IP [b-IETF RFC 791] and cellular or satellite communication technologies. From the industrial perspective, the factory external
+
+network provides dedicated lines, including an Internet dedicated line, an enterprise interconnection dedicated line and a cloud dedicated line:
+
+- The Internet dedicated line enables interconnection between enterprises and the Internet. This is the basic dedicated line for industrial enterprises.
+- The enterprise interconnection dedicated line enables safe and reliable interconnection between enterprise branches and enterprises. This is commonly used by large and medium-sized enterprises.
+- The cloud dedicated line enables interconnection between enterprises and cloud-based industrial data centres. It is usually a dedicated line from an enterprise to a cloud service provider.
+
+## **6.3 Service support and application support layer**
+
+The IIoT infrastructure part in the service support and application support layer consists of hardware facilities and software facilities.
+
+These facilities as the infrastructure in the service support and application support layer provide capabilities of integration of users and resources (such as data and services) inside and/or outside the enterprise, and further provide capabilities of industrial data integration analysis, in order to support the various industrial applications. They are a critical foundation for building industrial ecosystems for smart manufacturing.
+
+### **6.3.1 Hardware facilities**
+
+The hardware facilities in the service support and application support layer include different types of hardware such as application servers, edge computing nodes and storage. This is in order to help build hardware-type infrastructure for further building software-type infrastructure (the software facilities in the service support and application support layer).
+
+The hardware facilities facilitate interconnections among devices and systems enabling the collection of historical and real-time data, in order to achieve comprehensive and intelligent analysis.
+
+### **6.3.2 Software facilities**
+
+The software facilities in the service support and application support layer include different types of software such as programs, systems, platforms, operating systems, message brokers, message queues and databases.
+
+In this layer, the cloud-based software provides virtualized computing, storage and network resources, as well as fundamental cloud-based capabilities (such as distributed computing frameworks, cloud operating systems, development platforms for cloud-native applications, container engines, registries and container orchestration platforms), storage capabilities (such as distributed file systems and cloud databases), computing capabilities (such as big data programming paradigms and executing engines), and information system capabilities with help of coordination and cooperation mechanisms, in order to provide supporting capabilities for industrial services and applications. The users and industrial applications can use these resources and supporting capabilities.
+
+## **6.4 Industrial SDN**
+
+The industrial software-defined networking (SDN) [b-ITU-T Y.3300] uses network controllers to uniformly manage the network resources, so as to ensure the network quality of service (QoS) required by applications. The key mechanism of the industrial SDN is to manage and configure networking devices through software definition.
+
+With the utilization of advanced networking technologies, such as SDN and network functions virtualization (NFV) [b-ETSI NFV], the network can be virtualized. In this perspective, an SDN-based network can have different logical slides, which provide network services with different service
+
+level agreements (SLAs) [b-ITU-T M.1301]. These network services can be rapidly deployed, adjusted and recycled with high quality of service (QoS) [b-ITU-T E.800] guarantees.
+
+The industrial SDN is used throughout the device layer, the network layer and the service support and application support layer. The industrial SDN network is composed of terminal equipment in the device layer, programmable industrial SDN devices in the network layer and industrial SDN controllers in the service support and application support layer. A terminal equipment submits the data flow characteristics and transmission requirements to the appropriate industrial SDN controller(s) through the northbound interface. The industrial SDN controller(s) generates the forwarding rules of the industrial SDN network according to the received data flow characteristics and transmission requirements, and the forwarding rules are implemented in the programmable industrial SDN devices through the standardized southbound interface.
+
+NOTE – The industrial SDN may support one or multiple network controllers. There are different types of northbound interfaces [b-ONF TR-523] and southbound interfaces of the network controllers, those network controllers controlling the networking devices via southbound interfaces (using protocols such as network configuration protocol (NETCONF) [b-IETF RFC 6241], yet another next generation (YANG) [b-IETF RFC 6020], border gateway protocol – link state (BGP-LS) [b-IETF RFC 9085], BGP flow specification (BGP flow specification (flowspec)) [b-IETF RFC 8955], segment routing (SR) [b-IETF RFC 8402] and path computation element communication protocol (PCEP) [b-IETF RFC 5440]). Due to different types or manufacturers of networking devices (such as industrial switches, routers, gateways, firewalls, IPSs, virtual switches, industrial PON, and OTN), it may be complex to handle multiple protocols of northbound and southbound interfaces by a single network controller to achieve interoperability, so multiple network controllers may be used, which can be categorized as domain controllers and super controller. Each domain controller is intended to handle a part of the network (a domain), while the super controller is intended to control all the domain controllers, in order to realize cross domain management and coordination of the networking devices.
+
+The IT network and the OT network in the enterprise are traditionally operated independently of each other, the topologies of both networks are rigid, and the cross-network information interaction and management are very difficult. The industrial SDN enables the deep integration of the IT network and the OT network in order to build a flexible and agile industrial network. The equipment and traffic in the IT network and the OT network can be uniformly monitored and managed.
+
+## **6.5 Identification facilities**
+
+As one of the components of the IIoT infrastructure for smart manufacturing, the identification facilities provide identification capabilities for the identification of physical and logical resources.
+
+In the device layer, a unique identifier (ID) can be used to register and identify different kinds of devices, services and applications. In the network layer, an ID-based network communication can be leveraged to provide authentication and authorization capabilities to ensure the integrity and security of the information exchange. In the service support and applications support layer, the ID can be used as an entry to resolve the attributes, capabilities and services that are linked with the corresponding devices.
+
+## **6.6 Security and information protection facilities**
+
+The security and information protection facilities provide security and information protection capabilities for the different enterprise functions, including device authentication and authorization, physical security, functional security and information security.
+
+Those facilities are mainly used to protect various physical or virtual industrial resources, data analysis services, development kits, industrial applications, etc. They run through all the three layers of the IIoT infrastructure and address the different dimensions of security, including reliability, confidentiality, integrity, availability and information protection.
+
+# **7 Common characteristics and requirements of IIoT infrastructure for smart manufacturing**
+
+## **7.1 Common characteristics**
+
+The common characteristics of the IIoT infrastructure for support of smart manufacturing include:
+
+### **7.1.1 Integration**
+
+The IIoT infrastructure supports the full and efficient integration of information and data, connects elements within and among enterprises, as well as between enterprises and customers, and improves the response and delivery speed of enterprises to market changes and needs, in order to provide quick response by enterprises in terms of capabilities.
+
+The common integration characteristics of the IIoT infrastructure are as follows:
+
+- The IIoT infrastructure is based on ubiquitous perception, comprehensive connection and deep integration.
+- The IIoT infrastructure supports the collaboration of different businesses such as research and development (R&D), production and management inside the enterprise.
+- The IIoT infrastructure explores the optimal operation efficiency of the enterprise.
+- The IIoT infrastructure supports the collaboration of production resources and social resources outside the enterprise.
+- The IIoT infrastructure explores the optimal industrial resource allocation efficiency, and finally enables the capabilities of global collaboration.
+
+### **7.1.2 Compatibility**
+
+The IIoT infrastructure supports the transformation from existing industrial infrastructure in overlay mode or upgrading mode.
+
+NOTE 1 – The overlay mode is overlaying a new network and related equipment supporting the new business processes on the existing facilities to build another system other than the original system (e.g., deploying new monitoring equipment, sensing equipment and execution equipment on the existing industrial infrastructure to realize safety monitoring, data acquisition, analysis and optimization).
+
+NOTE 2 – The upgrading mode is upgrading the existing industrial facilities, network equipment and platform to realize the upgrading of system technologies and capabilities (e.g., at the process manufacturing site, original analogue instruments can be upgraded and replaced with intelligent instruments supporting 4th generation/5th generation (4G/5G), in order to realize the intelligent collection and aggregation of on-site data and the unmanned operation of dangerous sites).
+
+The IIoT infrastructure should not be bound to specific hardware or software facilities (e.g., hardware from a specific vendor, software working with the support of specific operating systems or database types, software using specific technologies which are capability limited or software structure or function which is hard to be modified and optimized), so as to ensure the flexibility of maintenance and expansion.
+
+The network of the IIoT infrastructure supports the capability of upgrading to, and to be compatible with networks enabling advanced technologies such as time-sensitive networking (TSN) [b-IEEE 802.1 TSN] and SDN.
+
+### **7.1.3 Scalability**
+
+The IIoT infrastructure supports the flexibility and scalability capabilities of computing, storage, and network resources. Those IIoT resources can be automatically scaled according to the business load, in order to adapt to the continuous evolution of functional modules, data resources and application capabilities.
+
+### **7.1.4 Efficiency and high performance**
+
+The IIoT infrastructure supports comprehensive adaptation to the efficiency and high performance requirements of IIoT under the conditions of sensitive industrial access data, complex application scenarios and high requirements for network service performances.
+
+The IIoT infrastructure can ensure the access quality (bandwidth, rate, delay, priority, etc.) of the connected facilities, in order to provide efficiency and high performance capabilities.
+
+### **7.1.5 Heterogeneous connectivity**
+
+The IIoT infrastructure meets the heterogeneous capabilities of the facilities in different layers of IIoT infrastructure in Figure 1, such as data collection and control devices in the device layer, diverse network type connectivity in the network layer and diverse computing and storage resources in the service support and application support layer, in order to provide services and capabilities across heterogeneous systems.
+
+### **7.1.6 Interoperability**
+
+The IIoT infrastructure interconnects facilities in the factory internal network and factory external network, builds a bottom-up, whole process and whole business information exchange system, in order to realize information exchange and interoperability within and across enterprises.
+
+### **7.1.7 Operational safety and reliability**
+
+The IIoT infrastructure supports operational safety capabilities such as endpoint protection, communication and connection protection, operational safety monitoring, analysis, configuration and management, and data protection.
+
+NOTE 1 – Operational safety refers to the aspects of safety that relate to the correct operation of a system, or which are provided by the system itself [ITU-T Y.4003].
+
+The IIoT infrastructure can realize high reliability of the hardware and software facilities. When a single hardware or software facility fails, it can ensure business continuity.
+
+NOTE 2 – Reliability refers to the probability that the system operates correctly for a given period of time in a given environment [ITU-T Y.4003].
+
+### **7.1.8 Security and sensitive information protection**
+
+The IIoT infrastructure supports capabilities to ensure the security of facilities, control, networks, applications and data. It supports comprehensive security capabilities such as system connection, system collaboration, data sharing and business cooperation.
+
+The IIoT infrastructure supports capabilities to prevent production facilities and products from misuse and unauthorised access [ITU-T Y.4003].
+
+The IIoT infrastructure supports capabilities of protection of IIoT users' personal information and protection of enterprises' sensitive information.
+
+### **7.1.9 Flexible and secure identification management and communication**
+
+An ID-based network can be leveraged to run through facilities in all the three layers of the IIoT infrastructure as shown in Figure 1, forming an ID registration and resolution system (such as the object identifier (OID) resolution system (ORS) [b-ITU-T X.672], the GS1 identification system [b-GS1] and the handle system [b-IETF RFC 3650]), in order to identify and resolve diverse IDs of physical and logical resources. The common characteristics of this system are as follows:
+
+- The ID registration and resolution system supports the unified operation, administration, and maintenance (OAM) of diverse identifiers.
+
+NOTE – The identifiers of the ID registration and resolution system can uniquely identify physical and logical resources for smart manufacturing. The physical resources include, but are not limited to, materials, machines and products, while the logical resources include, but are not limited to, production processes, software, digital models and data.
+
+- The ID registration and resolution system supports the registration and resolution of diverse identifiers.
+
+In order to provide flexible, efficient and trusted networking and communication capabilities, the IIoT infrastructure provides capabilities to support multiple network technology types (such as virtual local area network (VLAN) [b-IEEE 802.1Q] and virtual extensible local area network (VXLAN) [b-IETF RFC 7348]), multiple encryption security protocols (such as transport layer security (TLS) [b-IETF RFC 8446] and datagram transport layer security (DTLS) [b-IETF RFC 9147]), multiple tunnelling protocols (such as Internet protocol security (IPsec) [b-IETF RFC 4301], layer 2 tunnelling protocol (L2TP) [b-IETF RFC 3931], generic routing encapsulation (GRE) [b-IETF RFC 2784], software-defined wide area network (SD-WAN) [b-ITU-T Q.3741] and multiprotocol label switching virtual private network (MPLS VPN) [b-IETF RFC 4364]), and Internet protocol version 4 (IPv4) [b-IETF RFC 791] / Internet protocol version 6 (IPv6) [b-IETF RFC 8200] dual stack.
+
+### **7.1.10 Customized application support**
+
+The IIoT infrastructure mainly focuses on the upstream and downstream cooperation within the industrial chain, the common characteristics for customized application support are as follows:
+
+- The IIoT infrastructure provides reusable services.
+- The IIoT infrastructure supports a digital catalogue of reusable services and mechanisms for the discovery of services and service access endpoints.
+- The IIoT infrastructure supports an access control policy management system that enables the creation and management of policies related to access the services by different users and privileges.
+- The IIoT infrastructure supports the production and operation activities facing the whole industrial chain (such as R&D, production and manufacturing, supply chain, logistics and product operation and maintenance).
+- The IIoT infrastructure carries out the transaction of data and services throughout supply and demand, in order to realize information sharing and service collaboration within and among enterprises.
+
+## **7.2 High-level requirements**
+
+The high-level requirements of the IIoT infrastructure for support of smart manufacturing are as follows.
+
+### **7.2.1 Requirements for integration capabilities**
+
+The IIoT infrastructure is required to support capabilities of integration – including collaboration – as opposed to an isolated and silo-based approach of system development and deployment.
+
+The IIoT infrastructure is required to have the ability to support an ecosystem that includes all relevant stakeholders in the manufacturing value chain.
+
+### **7.2.2 Requirements for compatibility**
+
+The IIoT infrastructure is required to be compatible with existing facilities to interact with.
+
+This includes identification capabilities compatible with heterogeneous identification systems.
+
+### **7.2.3 Requirements for scalability**
+
+The IIoT infrastructure is required to be upgradable and expandable (diversity and number of devices, facilities, capabilities) according to the changing requirements of applications without significant impact on operational performances such as real-time, non real-time and high reliability performances, for continuous easy to use and maintain.
+
+### **7.2.4 Requirements for efficiency and high performance**
+
+The IIoT infrastructure is required to enable data exchanges of high volume, high quality of service, high reliability and strict latency (i.e., low latency and low jitter) guarantees, according to the requirements of network services and applications.
+
+The IIoT infrastructure is required to be efficient in terms of operations (data and functions).
+
+### **7.2.5 Requirements for heterogeneous connectivity**
+
+The IIoT infrastructure is required to support interworking among heterogeneous devices and facilities.
+
+### **7.2.6 Requirements for interoperability**
+
+The IIoT infrastructure is required to support communications and interactions across systems for the enablement of diverse network services and capabilities.
+
+### **7.2.7 Requirements for operational safety and reliability**
+
+The IIoT infrastructure is required to provide operational safety and reliability in order to exhibit low fault rates, high fault tolerance (i.e., the ability to keep correct operations even when faults occur) and robustness (i.e., the ability to guarantee basic functionalities in the event of a fault).
+
+### **7.2.8 Requirements for security and sensitive information protection**
+
+The IIoT infrastructure is required to support protection of production facilities and products from impermissible physical influences, e.g., protection against the entry into a room from unauthorized persons [ITU-T Y.4003].
+
+The IIoT infrastructure is required to support protection of the information and communication technology capabilities from impermissible influences via the communication interfaces of production facilities [ITU-T Y.4003].
+
+The IIoT infrastructure is required to support protection of information from loss and misuse, insurance of its timely provision to entitled users and maintenance of its integrity and confidentiality [ITU-T Y.4003].
+
+The IIoT infrastructure is required to provide protection of sensitive information. This includes protection of identities in the different identity management activities.
+
+### **7.2.9 Requirements for flexible and secure identification management and communication**
+
+The IIoT infrastructure is required to support flexible and secure identification management and communication according to the diversity of applications and facilities.
+
+The encoding and resolution mechanism of the ID registration and resolution system is required to be compatible with the encoding and resolution mechanisms of existing ID registration and resolution systems.
+
+ID-based network communication is required to enable various security functions (such as authentication, authorization and access control) and protect sensitive information of the communication objects.
+
+### **7.2.10 Requirements for customized application support**
+
+The IIoT infrastructure is required to provide application developers with a development support environment, operation support environment, service invocation and orchestration support, service operation management, multiple tenant management and other support functions.
+
+Customized applications can obtain data, analysis and processing capabilities provided by the IIoT infrastructure through unified interfaces (such as application programming interfaces (APIs) and web services).
+
+## **7.3 Layer level requirements**
+
+The following clauses identify the layer level requirements of the IIoT infrastructure for support of smart manufacturing.
+
+### **7.3.1 Device requirements**
+
+The device layer facilities provide the bottom layer I/O interfaces for communication and interaction between and among smart manufacturing facilities and the upper layer facilities of the IIoT infrastructure. The device layer facilities include basic functions (such as data perception, data identification, device control and execution) and specific smart manufacturing support functions (such as massive industrial data access, data conversion, data pre-processing and edge analysis).
+
+The device layer facilities are required to have the ability to support a variety of software and hardware methods for data collection. Collected data include assets properties, status and behaviour, e.g., temperature change data collected by temperature sensors during motor operation.
+
+The device layer facilities are required to set up a linkage between data and assets to define the objects represented by data. For example, it is necessary to clearly identify which sensor data represents the temperature information of a specific motor.
+
+The device layer facilities are required to have the ability to convert the expected target action into control signals. For example, the motions of the industrial robotic arm are converted into the rotation angle command signals of the motors.
+
+The device layer facilities are recommended to have the ability to change the asset status in the physical environment according to the control signals, including changing the mechanical and electrical status of the industrial equipment, as well as changing the operational processes for the personnel and supply chains.
+
+The device layer facilities are required to have the ability to access massive industrial data, including data access capabilities for industrial equipment (such as robotics, machine tools, and blast furnaces) and information systems (such as MES and ERP), in order to realize large-scale and comprehensive collection and interconnection of various industrial data.
+
+The device layer facilities are recommended to have the ability to unify the format and parse the semantics of multi-source heterogeneous collected data, and conduct data cleaning, compression, caching and other operations before transmitting them to the upper layer facilities.
+
+The device layer facilities are recommended to cope with real-time application scenarios, carry out real-time analysis and feedback control signals at the edge, and provide capabilities (such as resource scheduling, operation, maintenance, development and debugging) for edge application development.
+
+### **7.3.2 Network requirements**
+
+As described in clause 6, the network (part) of the IIoT infrastructure can be divided into a factory internal network and a factory external network.
+
+The factory internal network can be further divided into IT network and OT network. The OT network consists of different levels and at each level, different network technologies may be used. For instance, at the field level, various proprietary fieldbus and industrial Ethernet technologies are used
+
+to build manufacturing cells, a kind of small-scale local network, in order to support dedicated industrial control functions. As those proprietary protocols are not compatible among each other, the field level inter-connection and communication are not straightforward and can bring extra complexity to the management of the overall industrial system.
+
+In fact, the IIoT demands IT-OT convergence [b-ITU-T Y.2623] [b-ISO/IEC TR 30166] [b-IIRA] [b-Cigref] in order to make the manufacturing systems more flexible and intelligent. This allows traditional manufacturing equipment to communicate beyond their own manufacturing cells and even the geographical boundaries of enterprises or other industrial installations, thus enabling the remote monitoring, analysis and control of physical devices. To enable the "true" IT-OT convergence by breaking the barriers of the proprietary protocols and interoperability by facilitating the communication among factory internal network and factory external network, a unified large scale industrial network (ULSIN) is required as the network part of the IIoT infrastructure for support of smart manufacturing.
+
+The ULSIN is required to interconnect the factory internal network with the factory external network by industrial firewalls and gateways, in order to control appropriately the shared information from the factory internal network and protect against the threats from the factory external network.
+
+The ULSIN is required to support different network technologies, in order to provide comprehensive connectivity for the interconnection of the smart manufacturing ecosystem entities.
+
+The ULSIN is recommended to integrate all different devices, including drives, I/O modules, machines, servers, robot arms and others, into one network and support seamless communication among them. Compared with isolated manufacturing cells, each device in the IIoT infrastructure for manufacturing is recommended to be uniquely identified and reachable within the ULSIN. Among others, this can greatly increase the flexibility of the industrial control application design and enable communication among different production units, which is hard to achieve in existing manufacturing systems.
+
+The ULSIN is recommended to support the interoperability of the existing industrial infrastructure and devices. Since the existing industrial networks using diverse proprietary protocols are typically working in the physical and data-link layers, the ULSIN provides the capabilities required by the IIoT infrastructure in the network layer, thus avoiding direct conflict with the existing industrial networks. This enables integration of the existing industrial network technologies, such as fieldbuses, industrial Ethernet and wireless communication technologies, into the ULSIN without or with minimum adaptation, as well as seamless connectivity with other networks (located inside or outside the IIoT infrastructure borders).
+
+NOTE 1 – The ULSIN supports the interoperability with the existing industrial infrastructure and devices by providing common network layer capabilities, avoiding the need for gateways which are typically non-scalable. The application-level communication interoperability does not fall into the scope of ULSIN, being related to the upper layers of the network layer.
+
+The ULSIN is recommended to provide high performance in terms of bandwidth, latency and jitter, in order to support a large diversity of industrial services and applications: industrial services and applications usually do not demand high bandwidth, but are sensitive to latency; motion control applications typically run at a cycle time of sub-milliseconds, while other real time industrial applications do it at a cycle time from 1 ms to 100 ms; although non real time applications do not demand low latency, they may require time deterministic transmission, similarly to other industrial applications.
+
+The ULSIN is recommended to be capable of supporting real time industrial applications at the network layer. For motion control applications, whose control functions typically run at a cycle time of sub-milliseconds, it is recommended to leverage data link layer technologies like TSN. And the ULSIN is recommended to support motion control applications by bridging TSN networks.
+
+The ULSIN is recommended to provide high reliability of network level communications, according to the requirements of a large diversity of industrial services and applications. Differently from a network for residential users, an industrial system typically requires high reliability (from 99.999% to 99.99999%), including for the industrial network part, as unexpected or unintended service interruptions caused by network level failures could lead to huge loss in terms of production and business value.
+
+NOTE 2 – The packet duplication and elimination (PDE) technology specified in the TSN standards [b-IEEE 802.1 TSN] can be used to improve the reliability of the system at the expense of hardware infrastructure duplication. The protection switching technology specified in the ITU-T G.8031 standard [b-ITU-T G.8031] is another, although the current specification does not meet the requirements of real-time industrial applications while it can be used for non real-time industrial applications such as automated guided vehicle (AGV).
+
+### **7.3.3 Service support and application support requirements**
+
+The service support and application support layer facilities provide support capabilities of integration, interconnection and information fusion to fulfil the requirements of industrial digital transformation.
+
+NOTE – These facilities also integrate technologies such as edge-cloud collaboration, big data, artificial intelligence (AI) and microservices, in order to provide support for services and applications.
+
+The service support and application support layer facilities are required to provide high quality data resources for modelling and analysis.
+
+The service support and application support layer facilities are required to support system integration capabilities, in order to facilitate intensive utilization of data from different sources.
+
+The service support and application support layer facilities are recommended to support human-computer interaction, in order to enhance user experience.
+
+The service support and application support layer facilities are required to provide resource management capabilities including resource scheduling, operation and maintenance management.
+
+The service support and application support layer facilities are required to provide industrial data and model management capabilities (such as data governance, data sharing and data visualization).
+
+The service support and application support layer facilities are required to provide management capabilities for conducting retrieval, classification and identification of industrial data and models.
+
+The service support and application support layer facilities are recommended to integrate industrial modelling methods (such as application simulation analysis and service processes) and data science modelling methods (such as statistical analysis, data modelling based on big data and AI technologies), in order to realize in-depth mining and analysis of industrial data value.
+
+The service support and application support layer facilities are recommended to integrate tools for R&D, design, production management and operation management, as well as other tools (such as computer aided design (CAD), computer aided engineering (CAE), MES and ERP).
+
+The service support and application support layer facilities are recommended to adopt low code development, graphical programming and other technologies to facilitate development, which can support application personnel in carrying out efficient and flexible industrial application innovation.
+
+### **7.3.4 Industrial SDN requirements**
+
+The industrial SDN provides support capabilities for the network layer of IIoT infrastructure. It is used for agile and flexible OAM of network, and provides network services of high reliability and comprehensive interconnection.
+
+The industrial SDN is recommended to adopt a simplified network architecture, in order to enable flexible and simple network management.
+
+The industrial SDN is required to support the comprehensive connection of devices with different communication protocols, including devices that apply standard IP and Ethernet protocols, devices that apply industrial Ethernet protocols and devices that apply other communication protocols. The industrial SDN is required to identify and classify these protocols by programmable network devices, and forward data according to these protocols.
+
+The industrial SDN is required to support flexible networking of network devices.
+
+NOTE 1 – When communication relationships among network devices change, industrial SDN uses software-defined methods to modify forwarding rules, in order to quickly adapt to new networking modes and communication relationships.
+
+The industrial SDN is required to meet the transmission requirements of IT network services (such as control, collection and connection services) and OT network services (such as office automation (OA), Internet, fixed phone, video/audio conferencing and internal systems interconnections) at the same time, such as IT network services with high bandwidth requirements and OT network services with real-time and high reliability requirements.
+
+NOTE 2 – The industrial SDN centralized controller allocates network resources according to different transmission requirements, and manages them through bandwidth limitation, priority configuration and other OAM methods.
+
+The industrial SDN controller is required to detect connection of the network devices, analyse network failures and improve network security through traffic tracking and abnormal traffic monitoring.
+
+NOTE 3 – This is in order to provide unified capabilities for the IT-OT converged network, such as management of topologies, alarms, performances, audits and reports.
+
+The industrial SDN is recommended to support management visualization of the network.
+
+### **7.3.5 Identification requirements**
+
+The ID registration and resolution system, which is introduced in clause 7.1.9, is required to provide capabilities of ID data collection, ID management, ID registration, ID resolution, and ID data processing.
+
+### **7.3.6 Security and information protection requirements**
+
+Security and information protection requirements of the IIoT infrastructure are in line with the security and information protection requirements of the IoT, which refer to the functional requirements during capturing, storing, transferring, aggregating and processing the data of things, as well as to the provision of services which involve things [ITU-T Y.4100].
+
+The IIoT infrastructure is required to provide security and information protection capabilities at the different layers of the IIoT infrastructure framework. These capabilities include support of communication security, data management security, service provision security, integration of security policies and techniques, mutual authentication and authorization, and security audit [ITU-T Y.4100].
+
+# **8 Reference framework of the IIoT infrastructure capabilities for smart manufacturing**
+
+## **8.1 Reference framework**
+
+This clause describes a reference framework of the IIoT infrastructure capabilities.
+
+The reference framework integrates the intelligence enablement with the different layers of the IIoT infrastructure. This reference framework is built according to the two dimensions of intelligence [ITU-T Y.4003] and IoT [ITU-T Y.4000].
+
+Figure 2 illustrates the reference framework of the IIoT infrastructure capabilities for smart manufacturing.
+
+
+
+Figure 2 is a reference framework diagram showing the capabilities of IIoT infrastructure for smart manufacturing, structured by IoT layers and Intelligence dimensions.
+
+**IoT Dimension (Vertical Axis):**
+
+- Service support and application support layer:**
+ - Integration:** Storage support, Data processing support, Scalability support, HA and redundancy support.
+ - Interconnection:** Hardware and software facilities, Service management support, Resource management support.
+ - Information fusion:** Information sharing support, Data modelling support, Cloud-based management support.
+- Network layer:**
+ - Integration:** Factory external network (Network connectivity support), Factory internal network (Connectivity support, Forwarding, control and management support, Networking support).
+ - Interconnection:** Dedicated lines support, Multiple services support.
+ - Information fusion:** (Empty)
+- Device layer:**
+ - Integration:** Sensors and gateways (Access management support, Data collection and monitoring support, Control signals related support, Identification support, Edge computing support).
+ - Interconnection:** (Empty)
+ - Information fusion:** (Empty)
+
+**Intelligence Dimension (Horizontal Axis):**
+
+- Industrial SDN support**
+- Identification support**
+- Security and information protection support**
+
+Arrows indicate dependencies and interactions between components across layers and intelligence dimensions.
+
+Figure 2: Reference framework of the capabilities of IIoT infrastructure for smart manufacturing. The diagram is a 2D matrix with 'IoT' on the vertical axis and 'Intelligence' on the horizontal axis. The IoT axis is divided into three layers: Service support and application support layer, Network layer, and Device layer. The Intelligence axis is divided into three columns: Integration, Interconnection, and Information fusion. The Service support and application support layer contains: Integration (Storage support, Data processing support, Scalability support, HA and redundancy support), Interconnection (Hardware and software facilities, Service management support, Resource management support), and Information fusion (Information sharing support, Data modelling support, Cloud-based management support). The Network layer contains: Integration (Factory external network: Network connectivity support; Factory internal network: Connectivity support, Forwarding, control and management support, Networking support), Interconnection (Dedicated lines support, Multiple services support), and Information fusion (empty). The Device layer contains: Integration (Sensors and gateways: Access management support, Data collection and monitoring support, Control signals related support, Identification support, Edge computing support), Interconnection (empty), and Information fusion (empty). Arrows indicate dependencies: a vertical arrow from Device to Network layer, a vertical arrow from Network to Service layer, a horizontal arrow from Integration to Interconnection in the Network layer, and a horizontal arrow from Interconnection to Information fusion in the Service layer. On the right side, three vertical bars represent cross-cutting capabilities: Industrial SDN support, Identification support, and Security and information protection support.
+
+**Figure 2 – Reference framework of the capabilities of IIoT infrastructure for smart manufacturing**
+
+The IoT dimension in Figure 2 concerns different layers of IIoT infrastructure, according to the IoT reference model [ITU-T Y.4000], providing capabilities to support industrial services and applications.
+
+NOTE 1 – The industrial services and applications are not part of the IIoT infrastructure, they are supported by the IIoT infrastructure.
+
+NOTE 2 – The management capabilities of IIoT infrastructure are not positioned as cross-layer management capabilities as in the IoT reference model [ITU-T Y.4000], but are distributed across the three layers of the IoT dimension in order to provide a clear representation with regards to the intelligence dimension.
+
+The intelligence dimension in Figure 2 concerns the enablement of different layers of intelligence (smart capabilities) in the IIoT infrastructure, from intelligence at the integration layer to intelligence at the information fusion layer. By means of the IIoT infrastructure, those smart capabilities can be enabled for smart manufacturing.
+
+NOTE 3 – In the reference model of smart manufacturing in the context of the industrial IoT [ITU-T Y.4003], apart from the smart manufacturing applications and resources layers which concern, respectively, diverse applications based on different enterprise characteristics and diverse resources without generic characteristics, the integration, interconnection and information fusion layers are directly related to the IIoT infrastructure.
+
+NOTE 4 – The resources and smart manufacturing applications layers in the intelligence dimension of the smart manufacturing reference model focus, respectively, on the smart manufacturing resources and innovative industrial application patterns, which are highly related to the specific production processes and industrial applications of smart manufacturing. The smart manufacturing resources and applications in different industrial environments may have totally different characteristics and capabilities, but they do not constitute the general infrastructure of IIoT. On the other hand, the IIoT infrastructure concerns the digitalization of smart manufacturing resources and the application innovation with respect to the common requirements for support of general capabilities.
+
+The following clauses describe the two dimensions of the reference framework.
+
+### **8.1.1 IoT dimension**
+
+The IoT dimension concerns three layers: device layer, network layer and service support and application support layer.
+
+- 1) The "device layer" represents devices, such as sensors and gateways. It is the physical foundation of the data collection facilities. It supports the basic level of intelligence in the integration layer of the intelligence dimension. It provides capabilities of access management support, data collection and monitoring support, control signals related support, identification support and edge computing support, which are provided respectively in clause 8.2.1.
+- 2) The "network layer" represents the network infrastructure between the devices and the service support and application support layer facilities, and it is composed by the factory internal network and the factory external network.
+
+The factory internal network interconnects facilities in the device layer, the factory external network and the service support and application support layer. It supports the integration layer and the interconnection layer of the intelligence dimension. It provides capabilities of connectivity support, capabilities of forwarding, control and management support, and capabilities of networking support at the integration layer of the intelligence dimension, as well as capabilities of multiple services support at the interconnection layer of the intelligence dimension. These capabilities are provided respectively in clause 8.2.2.
+
+In addition to the factory external network interconnection with the factory internal network, the factory external network also interconnects facilities of the service support and application support layer, and exchanges data with facilities of the factory internal network and the service support and application support layer. According to the different layers of the intelligence dimension, the capabilities of the factory external network include network connectivity support at the integration layer of the intelligence dimension, and dedicated lines support at the interconnection layer of the intelligence dimension. These capabilities are provided respectively in clause 8.2.3.
+
+- 3) The "service support and application support layer" represents the infrastructure composed by the hardware and software facilities for supporting services and applications. According to the different layers of the intelligence dimension, the capabilities of the service support and application support layer include storage support, data processing support, scalability support, and high availability (HA) and redundancy support at the integration layer of the intelligence dimension. The capabilities of the service support and application support layer include service management support and resource management support at the interconnection layer of the intelligence dimension. The capabilities of the service support and application support layer include information sharing support, data modelling support and cloud-based management support for comprehensive information integration and fusion
+
+at the information fusion layer of the intelligence dimension. These capabilities are provided respectively in clause 8.2.4.
+
+NOTE – Appropriate technologies such as cloud computing, big data, AI, digital twin, information security and other emerging information technologies are key enablers for the depth and breadth of information fusion, in order to achieve smart manufacturing.
+
+The cross-layer capabilities include industrial SDN support and support of identification and security and information protection.
+
+The industrial SDN support capabilities, which cross the network layer and the service support and application support layer, provide the support for uniform management of the network resources, and for facilitating the IT-OT convergence, in order to enable an agile and flexible industrial network. These capabilities are provided in clause 8.2.5.
+
+On the premise of identification and security and information protection, the IIoT infrastructure provides capabilities of identification support, and security and information protection support, throughout all the three layers of the IoT dimension. These capabilities are provided in clauses 8.2.6 and 8.2.7.
+
+### **8.1.2 Intelligence dimension**
+
+The intelligence dimension concerns three layers: integration, interconnection and information fusion.
+
+- 1) The "integration" layer enables the fundamental integration capabilities from data collection and data exchange to data storage and data management, with respect to the facilities of all layers in the IoT dimension.
+
+In the device layer, via collecting and processing data by sensors and gateways, the integration layer interconnects devices with the facilities of the network layer for data transmission and exchange.
+
+In the network layer, via interconnection between the factory internal network and the factory external network, the integration layer realizes reliable transmission of data.
+
+In the service support and application support layer, via comprehensive integration of the hardware and software facilities, the integration layer supports diverse services and applications.
+
+- 2) The "interconnection" layer enables interconnection capabilities with respect to the network layer and the service support and application support layer in the IoT dimension.
+
+In the network layer, the interconnection layer supports the interconnection of the entities of the smart manufacturing ecosystem.
+
+In the service support and application support layer, the interconnection layer supports management capabilities for services and resources.
+
+- 3) The "information fusion" layer enables information interconnection and coordination capabilities throughout enterprises, with respect to the service support and application support layer in the IoT dimension.
+
+In the service support and application support layer, the information fusion layer supports information fusion for services and applications.
+
+## **8.2 Details on the capabilities**
+
+Details of the IIoT infrastructure capabilities are provided in this clause according to the IoT dimension layering of Figure 2.
+
+### 8.2.1 Device capabilities
+
+#### 1) Access management support
+
+- support of access management with different security strategies, including, but not limited to, authentication, authorization, encryption and protection;
+- support of necessary authentication and authorization processes of the connected objects, and interception of unauthorized access;
+- support of access rights limitation;
+NOTE 1 – Only data which has been pre-defined in terms of access rights can be accessed, and this is in order to prevent accessing and tampering with restricted data.
+- support of high bandwidth;
+NOTE 2 – 1 to 10 Gbit/s bandwidth, even higher, is expected to be supported for video-based services and applications.
+- support of data flow classification and priority differentiation;
+- support of device management protocols, including, but not limited to, oneM2M [b-ITU-T Y.4500.x];
+- support of remote operations, including, but not limited to, access isolation and control of online/offline status (such as shutdown and reboot);
+- support of remote firmware management and remote configuration upgrading, especially for manageable devices such as sensors and gateways.
+
+#### 2) Data collection and monitoring support
+
+- support of data collection via diverse protocols;
+NOTE 3 – Examples of protocols include, but are not limited to, Ethernet, RS232 and RS485 for dedicated industrial devices and control systems, and message queuing telemetry transport (MQTT) [b-ISO/IEC 20922], enhanced device protocol (EDP) [b-EDP], hypertext transfer protocol (HTTP) [b-IETF RFC 9114], constrained application protocol (CoAP) [b-IETF RFC 7252] and short message peer-to-peer (SMPP) [b-SMPP].
+- support of data collection with different data formats, including, but not limited to, data sets, logs and files;
+- support of collection data conversion to unified data formats;
+- support of local storage of collected data;
+- support of submitting collected data upward to the hardware and software facilities for further analysis and storage;
+- support of real-time monitoring of operational status, including, but not limited to, device status, start time, operating and idle time, faults, alarms, production parameters and operation parameters;
+- support of status monitoring of network links, including, but not limited to, connection status, transmission delay status and routing status.
+
+#### 3) Control signals related support
+
+- support of converting the expected target control actions into specific control signals;
+- support of changing the asset status in the physical environment according to the control signals.
+
+#### 4) Identification support
+
+- support of identification of physical and logical resources with unique identifiers, and their registration.
+
+- 5) Edge computing support
+- support of pre-processing data, including, but not limited to, data integrity and consistency checking, abnormal data identification and processing, missing data identification, redundant and useless data cleaning for further data modelling and analysis;
+ - support of detecting and locating fault scope and fault locations according to the monitoring information of operational status and network link status;
+ - support of determination and execution of emergency actions (such as emergency shutdown) according to the fault level;
+ - support of edge application development capabilities, including, but not limited to, resource scheduling, operation, maintenance, development and debugging.
+
+### 8.2.2 Factory internal network capabilities
+
+- 1) Connectivity support
+- support of interconnection among diverse connected objects (such as sensors and gateways, smart manufacturing devices and other resources) and systems inside the enterprise;
+ - support of accessing industrial equipment via diverse technologies, including, but not limited to, industrial field buses, industrial Ethernet and industrial wireless networks.
+- 2) Forwarding, control and management support
+- support of non real-time data and real-time data forwarding of collected data, control and management data;
+ - support of backwards compatibility and interoperability with the legacy industrial systems by applying techniques for cross communication, such as tunnelling techniques;
+ - support of network control, including, but not limited to, generation of routing and flow tables, path selection, interconnection of routing protocols, access control list (ACL) and QoS configurations;
+ - support of network management, including, but not limited to, management of QoS, network topology, network access, network resources.
+- 3) Networking support
+- support of multiple labelling protocols, including, but not limited to, VLAN and VXLAN;
+ - support of multiple tunnelling protocols, including, but not limited to, IPsec, L2TP, GRE, SD-WAN and MPLS VPN;
+ - support of IPv4/IPv6 dual stack;
+ - support of capabilities enabling high performance networking, including, but not limited to, capabilities for support of high bandwidth, strict latency, high reliability, high frequency transmission, high capacity connectivity, high mobility, high data forwarding priority, long transmission distance and high communication anti-interference, according to the different service and application requirements;
+
+NOTE 1 – As an example, remote control services require specific delay and bandwidth performances. E.g., video based remote control service normally requires a delay not larger than 20 ms, and the network should provide relative bandwidth guarantees (e.g., high-definition video surveillance normally requires a gigabit-level of bandwidth, and automatic optical inspection system implemented on the production line normally requires a bandwidth from 1 to 10 Gbit/s, or even higher) according to the specific remote control video resolution requirements.
+
+NOTE 2 – As another example, control services require different low latency and low packet loss transmission performances. For motion control applications, the end-to-end (E2E) latency should be less than 100 $\mu$ s. For real time industrial applications (non-motion control), the E2E latency should be less than 1-100 ms. The packet loss ratio should range from 99.999% to 99.99999%.
+
+NOTE 3 – As another example, connection services, such as wireless connected AGVs, require high frequency transmission, high capacity connectivity and high mobility.
+
+NOTE 4 – As another example, considering the poor anti-interference performance of copper cables, the industrial PON technology can be adopted to avoid electromagnetic interferences within optical fibre cables.
+
+- support of load balancing and fault recovery;
+- support of network physical isolation or logical isolation, providing strictly limited access control;
+- support of open architectures and protocols to not prevent network expansion.
+
+#### 4) Multiple services support
+
+- support of OT network services, including, but not limited to, control, collection and connection services;
+
+NOTE 5 – The control services include local and remote control services.
+
+NOTE 6 – The collection services include, but are not limited to, information collection services, video detection and collection services.
+
+NOTE 7 – The connection services include, but are not limited to, device programme download service, production processing programme download service, AGV navigation service, remote diagnosis, and maintenance guidance service.
+
+- support of IT network services, including, but not limited to, OA, Internet, fixed phone, video/audio conferencing and internal systems interconnections;
+
+NOTE 8 – The internal systems interconnection services provide interconnection of internal systems, including, but not limited to, MES, ERP, PLM, CRM, SCM and safety protection systems.
+
+- support of rapid deployment, adjustment and recycle of OT and IT network services.
+
+### 8.2.3 Factory external network capabilities
+
+#### 1) Network connectivity support
+
+- support of interconnection with the factory internal network by industrial firewalls and gateways;
+
+NOTE 1 – As an example, the access from the factory external network to the factory internal network is controlled and filtered by industrial firewalls, and firewalls record the accessing operations and backtrack security audits.
+
+- support of interconnection with industrial fixed networks, wireless networks, Internet and dedicated networks.
+
+#### 2) Dedicated lines support
+
+- support of dedicated lines among different networks with specific E2E SLAs according to the service and application requirements;
+- support of Internet dedicated lines;
+
+NOTE 2 – The Internet dedicated lines can be classified as general and dedicated Internet services. The general Internet service provides best-effort data transmission and forwarding capabilities for low requirements of delay, reliability and flexibility. The dedicated Internet service provides communication links for higher requirements.
+
+- support of enterprise interconnection dedicated lines;
+
+NOTE 3 – As examples, the enterprise interconnection dedicated lines can be provided by virtual dedicated lines (e.g., by using SD-WAN, IPsec and MPLS VPN), physically isolated dedicated lines (e.g., by using SDH and OTN), network slicing, etc.
+
+- support of cloud dedicated lines;
+
+NOTE 4 – As examples, the cloud dedicated lines may provide capabilities of fixed routing configuration, seamless resources expansion, exclusive utilization, high security and performance.
+
+- support of rapid deployment, adjustment and recycle of the dedicated lines.
+
+### **8.2.4 Service support and application support capabilities**
+
+#### **1) HA support**
+
+- support of HA of application servers, edge computing nodes, storage and other hardware and software facilities;
+- support of service or function migration;
+- support of load balancing to prevent access and process overload;
+- support of periodic full and incremental backup mechanism for rapid data disaster recovery.
+
+#### **2) Scalability support**
+
+- support of flexible scalability for hardware and software facilities, in order to adapt capability expansion and maintenance of data resources, functional modules and applications;
+- support of dynamic adjustment of hardware and software resources according to the service and application loads and requirements.
+
+#### **3) Data processing support**
+
+- support of data conversion abilities, including, but not limited to, conversion of data format and data type according to the requirements of applications, such as system upgrade, data integration, data migration, data exchange, data cleaning, data standardization, data security, data compression and data model change;
+- support of data organization according to unified service rules or functional modules;
+- support of data access abilities, including, but not limited to, re-organizing, splitting and mapping;
+- support of data quality monitoring automation;
+
+NOTE 1 – As an example, the device operation log files can be analysed and evaluated by personalized data quality monitoring rules, in order to generate periodic maintenance task, or find potential risks of the devices and raise warnings to perform predictive maintenance actions.
+
+- support of human-computer interaction for enhanced user experience;
+- support of integration capabilities for data. These capabilities include, but are not limited to, big data programming paradigms and executing engines;
+- support of high concurrency and low latency of data processing;
+- support of online and offline big data computing;
+- support of big data computing modes, including, but not limited to, real-time computing (such as stream computing), non real-time computing (such as batch computing), graph-based computing and interactive computing;
+
+NOTE 2 – The interactive computing mode is mainly used for real-time interactive query and data analysis, such as report generation of large data warehouses. The interactive computing mode needs processing performances of high concurrency and low latency with the characteristics of high query complexity.
+
+- support of distributed computing frameworks, including, but not limited to, structured query language (SQL) [b-ISO/IEC 9075-x] and other big data computing frameworks;
+- support of programming frameworks for relation-based data objects, in order to provide capabilities of intuitive and easy operation and management of data objects;
+- support of seamless integration of big data computing frameworks.
+
+#### 4) Storage support
+
+- support of rational databases such as SQL and non-rational databases such as not only SQL (NoSQL);
+ - support of centralized and distributed storage;
+ - support of high-speed writing and reading of data;
+ - support of dynamic expansion and contraction of storage capacity;
+ - support of data filtering, in order to store different types of data into different databases and data sheets, and filter error data and other abnormal data;
+ - support of data dictionary;
+- NOTE 3 – For user repacked irregular data, the storage can compare and analyse them using a data dictionary, in order to acquire and store actual data.
+- support of tiered data storage.
+
+NOTE 4 – As an example, storing hot (real-time or high frequency accessed) data into a database which have specific real-time performance, and storing other data in database for long-term data, with the real-time database synchronizing with the long-term database at an appropriate time interval.
+
+#### 5) Resource management support
+
+- support of resource management, including, but not limited to, management of homogeneous and heterogeneous computing, storage and network resources;
+- support of status monitoring of computing, storage and network resources, and raising warnings or alarms while these resources are in abnormal status;
+- support of industrial data and model management.
+
+#### 6) Service management support
+
+- support of centralized management of services (such as database services and load balancing services), as well as service lifecycle management; support of flexible interaction (i.e., adopt service and application functional modular design) among different service modules;
+- support of providing reusable services;
+- support of resources orchestration and collaboration of multiple services for service resource expansion and rapid service deployment;
+- support of industrial processes and tools integration, and adoption of low code development, graphical programming and other technologies for efficient and flexible service and application innovation.
+
+#### 7) Cloud-based management support
+
+- support of management of virtualized resources, including, but not limited to, virtualized computing, storage and network resources;
+- support of management of private cloud, public cloud and hybrid cloud;
+- support of management of cloud services, including, but not limited to, infrastructure as a service (IaaS), platform as a service (PaaS), and software as a service (SaaS).
+
+- 8) Data modelling support
+- support of data modelling;
+NOTE 5 – As an example, creating device object models based on abstracting the device objects, in order to rapidly create different device model instances.
+NOTE 6 – As another example, creating different production process models, in order to realize collaboration mechanism among different production processes.
+ - support of multi-type and multi-dimension semantics and models, in order to build generic semantic and model libraries for the support of data modelling from different industrial services and applications.
+- 9) Information sharing support
+- support of information sharing among different services and applications;
+ - support of information sharing via different application layer communication modes, including, but not limited to, request/response mode and publish/subscribe mode;
+ - support of distributed ledger technologies such as blockchain, in order to leverage their characteristics for information sharing. Those characteristics include, but are not limited to, consensus, smart contract, immutability, data sharing, decentralization and tamper-resistance [b-ITU-T X.1409].
+
+### **8.2.5 Industrial SDN capabilities**
+
+- support of NFV for specific purposes. These specific purposes include, but are not limited to, network isolation and support of multiple services;
+- support of rapid deployment, adjustment and recycle of network services with different SLAs;
+- support of control and adjustment of network resources, in order to improve operation and maintenance efficiency;
+- support of providing comprehensive and unified authentication and authorization mechanisms to enhance the protection ability against threats and to protect sensitive information;
+- support of comprehensive visualization of network traffic and providing full path fault detection capability, in order to reduce the cost of network OAM;
+- support of unified network configuration policy, in order to ensure the seamless access and consistent experience of legitimate users in different network environments;
+NOTE – Network environments refer to the diversity of networks in terms of geographic distribution, organizational structure, technological implementation and service requirements.
+- support of multiple communication protocols, including, but not limited to, IP, Ethernet and industrial Ethernet;
+- support of unified management protocols, including, but not limited to, NETCONF, YANG and simple network management protocol (SNMP) [b-IETF RFC 3411].
+
+### **8.2.6 Identification capabilities**
+
+- support of ID data collection via different communication technologies, including, but not limited to, wireline and wireless technologies;
+- support of management of diverse IDs;
+- support of registration and resolution of diverse IDs using the encoding and resolution mechanism, compatible with existing ID registration and resolution systems and platforms;
+- support of processing of ID data.
+
+### **8.2.7 Security and information protection capabilities**
+
+The security capabilities of the IIoT infrastructure include generic security capabilities and specific security capabilities [ITU-T Y.4003].
+
+Generic security capabilities are in line with the basic security capabilities of IoT [ITU-T Y.4401], including capabilities of communication security, data management security, service provision security, security integration, mutual authentication and authorization, and security audit, which are independent of industrial applications.
+
+Specific security capabilities are closely coupled with application-specific requirements [ITU-T Y.4000], e.g., production material management security requirements and enterprise management security requirements.
+
+The information protection capabilities of the IIoT infrastructure include protection of IIoT users' personal information and protection of enterprises' sensitive information, involving the protection of identities during the different identity management activities.
+
+# **9 Security considerations**
+
+In order to mitigate security threats such as network attacks faced by IIoT, the IIoT infrastructure should comprehensively consider information and communication security. Best practices should be adopted when using IIoT in industrial environments.
+
+Furthermore, IIoT infrastructure security and information protection should facilitate security of other IIoT-related industrial resources, such as IIoT infrastructure connected manufacturing resources, and industrial applications like smart manufacturing applications, throughout the three dimensions of the smart manufacturing reference model [ITU-T Y.4003].
+
+# Bibliography
+
+- [b-ITU-T E.800] Recommendation ITU-T E.800 (2008), *Definitions of terms related to quality of service*.
+- [b-ITU-T G.671] Recommendation ITU-T G.671 (2019), *Transmission characteristics of optical components and subsystems*.
+- [b-ITU-T G.803] Recommendation ITU-T G.803 (2000), *Architecture of transport networks based on the synchronous digital hierarchy (SDH)*.
+- [b-ITU-T G.872] Recommendation ITU-T G.872 (2024), *Architecture of the optical transport network*.
+- [b-ITU-T G.8031] Recommendation ITU-T G.8031/Y.1342 (2015), *Ethernet linear protection switching*.
+- [b-ITU-T H.320] Recommendation ITU-T H.320 (2004), *Narrow-band visual telephone systems and terminal equipment*.
+- [b-ITU-T M.1301] Recommendation ITU-T M.1301 (2001), *General description and operational procedures for international SDH leased circuits*.
+- [b-ITU-T Q.3741] Recommendation ITU-T Q.3741 (2019), *Signalling requirements for SD-WAN service*.
+- [b-ITU-T X.200] Recommendation ITU-T X.200 (1994) | ISO/IEC 7498-1:1994, *Information technology – Open Systems Interconnection – Basic Reference Model: The basic model*.
+- [b-ITU-T X.672] Recommendation ITU-T X.672 (2022) | ISO/IEC 29168-1:2023, *Information technology – Open systems interconnection – Object identifier resolution system*.
+- [b-ITU-T X.1409] Recommendation ITU-T X.1409 (2022), *Security services based on distributed ledger technology*.
+- [b-ITU-T Y.2623] Recommendation ITU-T Y.2623 (2021), *Requirements and framework of industrial Internet networking based on future packet based network evolution*.
+- [b-ITU-T Y.3300] Recommendation ITU-T Y.3300 (2014), *Framework of software-defined networking*.
+- [b-ITU-T Y.4500.x] Recommendation ITU-T Y.4500.x-series (2018), *oneM2M Recommendation series*.
+- [b-ISO/IEC 9075-x] ISO/IEC 9075-x-series:2023, *Information technology – Database languages SQL*.
+<>
+- [b-ISO/IEC 20922] ISO/IEC 20922:2016, *Information technology – Message Queuing Telemetry Transport (MQTT) v3.1.1*.
+<>
+- [b-ISO/IEC TR 23188] ISO/IEC TR 23188:2020, *Information technology – Cloud computing — Edge computing landscape*.
+<>
+- [b-ISO/IEC TR 30166] ISO/IEC TR 30166:2020, *Internet of things (IoT) – Industrial IoT*.
+<>
+
+- [b-IEC 61158-1] IEC 61158-1:2010 ED3, *Industrial communication networks – Fieldbus specifications – Part 1: Overview and guidance for the IEC 61158 and IEC 61784 series*.
+<[https://www.iec.ch/dyn/www/f?p=103:38:503848804511957:::FSP\\_ORG\\_ID,FSP\\_APEX\\_PAGE,FSP\\_PROJECT\\_ID:1376,20,17801](https://www.iec.ch/dyn/www/f?p=103:38:503848804511957:::FSP_ORG_ID,FSP_APEX_PAGE,FSP_PROJECT_ID:1376,20,17801)>
+- [b-IEC 61784-2-3] EN IEC 61784-2-3:2023, *Industrial networks – Profiles – Part 2-3: Additional real-time fieldbus profiles based on ISO/IEC/IEEE 8802-3 – CPF 3*.
+<>
+- [b-IEC 62601] IEC 62601:2015, *Industrial networks – Wireless communication network and communication profiles – WIA-PA*.
+<>
+- [b-IEC 62948] IEC 62948:2017, *Industrial networks – Wireless communication network and communication profiles – WIA-FA*.
+<>
+- [b-3GPP TS 36.300] 3GPP TS 36.300 V17.5.0 (2023), *Evolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Universal Terrestrial Radio Access Network (E-UTRAN); Overall description; Stage 2 (Release 17)*.
+<[https://www.3gpp.org/ftp/Specs/latest/Rel-17/36\\_series](https://www.3gpp.org/ftp/Specs/latest/Rel-17/36_series)>
+- [b-Bluetooth] Bluetooth SIG (2021), Bluetooth Core Specification v5.3.
+<[https://www.bluetooth.org/DocMan/handlers/DownloadDoc.ashx?doc\\_id=521059](https://www.bluetooth.org/DocMan/handlers/DownloadDoc.ashx?doc_id=521059)>
+- [b-Cigref] Cigref report, (2020), *IT/OT convergence: A fruitful integration of information systems and operational systems*.
+<>
+- [b-EDP] China Mobile – Device Terminal Access Protocol – EDP V1.6, (2017), *Enhanced Device Protocol (EDP)*.
+<>
+- [b-ETSI GR F5G 007] ETSI GR F5G 007 v1.1.1 (2023), *Fifth Generation Fixed Network (F5G); F5G Industrial PON*.
+<[https://www.etsi.org/deliver/etsi\\_gr/F5G/001\\_099/007/01.01.01\\_60/gr\\_F5G007v010101p.pdf](https://www.etsi.org/deliver/etsi_gr/F5G/001_099/007/01.01.01_60/gr_F5G007v010101p.pdf)>
+- [b-ETSI NFV] ETSI ISG NFV (2023), *Network Functions Virtualisation (NFV)*.
+<>
+- [b-GS1] GS1 General Specifications (2024), Release 24.0, *GS1 General Specifications Standard*.
+< >
+- [b-IEEE 802.1 TSN] Farkas, A., Bello, L.L., and Gunther, C. (2018), *Time-Sensitive Networking Standards*. IEEE Communications Standards Magazine. Volume 2, Issue 2.
+<>
+- [b-IEEE 802.1Q] ISO/IEC/IEEE 8802-1Q:2024, *Telecommunications and exchange between information technology systems – Requirements for local and metropolitan area networks – Part 1Q: Bridges and bridged networks*.
+<>
+
+- [b-IEEE 802.3] IEEE 802.3-2022, *IEEE Standard for Ethernet*.
+< >
+- [b-IEEE 802.11] ISO/IEC/IEEE 8802-11:2022, International Standard – *Telecommunications and information exchange between systems – Specific requirements for local and metropolitan area networks – Part 11: Wireless LAN medium access control (MAC) and physical layer (PHY) specifications*.
+< >
+- [b-IETF RFC 791] IETF RFC 791 (1981), *Internet Protocol*.
+<>
+- [b-IETF RFC 1180] IETF RFC 1180 (1991), *A TCP/IP Tutorial*.
+<>
+- [b-IETF RFC 2784] IETF RFC 2784 (2000), *Generic Routing Encapsulation (GRE)*.
+<>
+- [b-IETF RFC 3411] IETF RFC 3411 (2024), *An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks*.
+< >
+- [b-IETF RFC 3650] IETF RFC 3650 (2003), *Handle System Overview*.
+<>
+- [b-IETF RFC 3931] IETF RFC 3931 (2005), *Layer Two Tunneling Protocol – Version 3 (L2TPv3)*.
+<>
+- [b-IETF RFC 4301] IETF RFC 4301 (2005), *Security Architecture for the Internet Protocol*.
+<>
+- [b-IETF RFC 4364] IETF RFC 4364 (2006), *BGP/MPLS IP Virtual Private Networks (VPNs)*.
+<>
+- [b-IETF RFC 5440] IETF RFC 5440 (2009), *Path Computation Element (PCE) Communication Protocol (PCEP)*.
+<>
+- [b-IETF RFC 6020] IETF RFC 6020 (2010), *YANG – A Data Modeling Language for the Network Configuration Protocol (NETCONF)*.
+<>
+- [b-IETF RFC 6241] IETF RFC 6241 (2011), *Network Configuration Protocol (NETCONF)*.
+<>
+- [b-IETF RFC 7252] IETF RFC 7252 (2014), *The Constrained Application Protocol (CoAP)*.
+<>
+- [b-IETF RFC 7348] IETF RFC 7348 (2014), *Virtual eXtensible Local Area Network (VXLAN): A Framework for Overlaying Virtualized Layer 2 Networks over Layer 3 Networks*.
+<>
+
+- [b-IETF RFC 8200] IETF RFC 8200 (2017), *Internet Protocol, Version 6 (IPv6) Specification*.
+<>
+- [b-IETF RFC 8402] IETF RFC 8402 (2018), *Segment Routing Architecture*.
+<>
+- [b-IETF RFC 8446] IETF RFC 8446 (2018), *The Transport Layer Security (TLS) Protocol Version 1.3*.
+<>
+- [b-IETF RFC 8955] IETF RFC 8955 (2020), *Dissemination of Flow Specification Rules*.
+<>
+- [b-IETF RFC 9085] IETF RFC 9085 (2021), *Border Gateway Protocol – Link State (BGP-LS) Extensions for Segment Routing*.
+<>
+- [b-IETF RFC 9114] IETF RFC 9114 (2022), *HTTP/3*.
+<>
+- [b-IETF RFC 9147] IETF RFC 9147 (2022), *The Datagram Transport Layer Security (DTLS) Protocol Version 1.3*.
+<>
+- [b-IIRA] Industry IoT Consortium (IIC) (2022), *The Industrial Internet Reference Architecture, Version 1.10*.
+<>
+- [b-ISA-100.11a] ANSI/ISA-100.11a-2011, *Wireless systems for industrial automation: Process control and related applications*.
+<>
+- [b-ONF TR-523] ONF TR-523 (2016), *Intent NBI – Definition and Principles*.
+<[https://opennetworking.org/wp-content/uploads/2014/10/TR-523\\_Intent\\_Definition\\_Principles.pdf](https://opennetworking.org/wp-content/uploads/2014/10/TR-523_Intent_Definition_Principles.pdf)>
+- [b-SCADA] ISA112, SCADA Systems.
+<>
+- [b-SMPP] SMS Forum (2003), *Short Message Peer-to-Peer Protocol Specification v5.0*.
+<[https://smpp.org/SMPP\\_v5.pdf](https://smpp.org/SMPP_v5.pdf)>
+- [b-TIA-232] TIA-232-F, (1997), *Interface Between Data Terminal Equipment and Data Circuit- Terminating Equipment Employing Serial Binary Data Interchange*.
+<[https://global.ihs.com/doc\\_detail.cfm?&csf=TIA&item\\_s\\_key=00125234&item\\_key\\_date=870024&input\\_doc\\_number=232&input\\_doc\\_title=&org\\_code=TIA](https://global.ihs.com/doc_detail.cfm?&csf=TIA&item_s_key=00125234&item_key_date=870024&input_doc_number=232&input_doc_title=&org_code=TIA)>
+- [b-TIA-485] TIA-485-A, (1998), *Electrical Characteristics of Generators and Receivers for Use in Balanced Digital Multipoint Systems*.
+<[https://global.ihs.com/doc\\_detail.cfm?&csf=TIA&item\\_s\\_key=00032964&item\\_key\\_date=870024&input\\_doc\\_number=485&input\\_doc\\_title=&org\\_code=TIA](https://global.ihs.com/doc_detail.cfm?&csf=TIA&item_s_key=00032964&item_key_date=870024&input_doc_number=485&input_doc_title=&org_code=TIA)>
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+| Series Y | Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities |
+| Series Z | Languages and general software aspects for telecommunication systems |
\ No newline at end of file
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..d4d8969f805414689ab79cfd08c333d454d482b3
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/2d4807f80a3f0106f1722d5722cfac87_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:636c3839edff955a5b6208530b05fa1c983ab153d90f00216517a7a99478b988
+size 7074
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/4b0f6b9fffe1f9b12f0db27b76e617ca_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/4b0f6b9fffe1f9b12f0db27b76e617ca_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3b574fe40d11b7a42997d6e01eae594deb5b216e
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/4b0f6b9fffe1f9b12f0db27b76e617ca_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:090cd22353a49c694d7b54df7f0a8f1546097584671d30f6d09397e035d5e1e3
+size 31706
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/6b29ab7e77b37eb167c955b26206c169_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/6b29ab7e77b37eb167c955b26206c169_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..07ccddd1b2b8260e2587c589c1ba9e7c42a95c01
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/6b29ab7e77b37eb167c955b26206c169_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:19bf9042236ef5444d83df62b142e16e1f5403aaa2f67cb050ab543aff183042
+size 47597
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..4b80c5f9603bfd589c5417e64eedb48e52a2a2cf
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/83852ec55d4802521a727926336bedab_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:c1d7892e2939c4d2a460a7e58ae038570b33002dfb671d294e766eec07599afd
+size 72689
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c8ce893988a155b37a5104376d244f09c41804c1
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/a83ba9e3e2c1e21dd69953a7b09e45b4_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:4c4ea6db30ef0edefaf6e6c35b07a2afa66234e8526f1547b75891786ca79b62
+size 64105
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/b91e305493a4852dca57a801f54085c8_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/b91e305493a4852dca57a801f54085c8_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..c159e7aa1e8d83e20136f9b02bcf6e0af804097d
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/b91e305493a4852dca57a801f54085c8_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:bbd4baffff66236f3c0bea8416c333adbca373a603e32d274f1de41b8b6f0032
+size 82704
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..20c119201a69963c2d1ae1e3f2c446974c1f99b0
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/c2fc2621e8206d24427b56bcb2398fc0_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:2fbba36bcae4a4207c04e6a352e7f74e962b4215cc3aa4b17853b86735f29660
+size 53304
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
new file mode 100644
index 0000000000000000000000000000000000000000..3c2c573ca1f10f91befac38031c7fa590078ac99
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/ef96fcba3a34e9e35ff8ee3cc8cb7b20_img.jpg
@@ -0,0 +1,3 @@
+version https://git-lfs.github.com/spec/v1
+oid sha256:ed791d7f5c2becfebd936e81d76d549a6d63ce9ac447b72f4aa943344a4d99be
+size 25225
diff --git a/marked/Y/T-REC-Y.4231-202501-I_PDF-E/raw.md b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/raw.md
new file mode 100644
index 0000000000000000000000000000000000000000..769ad1e11f1662c8c6f2a6c3fe2b270e30e5d71e
--- /dev/null
+++ b/marked/Y/T-REC-Y.4231-202501-I_PDF-E/raw.md
@@ -0,0 +1,813 @@
+
+
+# Recommendation
+
+## **ITU-T Y.4231 (01/2025)**
+
+SERIES Y: Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+Internet of things and smart cities and communities –
+Requirements and use cases
+
+---
+
+## **Requirements and capability framework of the Internet of things for vision**
+
+## ITU-T Y-SERIES RECOMMENDATIONS
+
+## Global information infrastructure, Internet protocol aspects, next-generation networks, Internet of Things and smart cities
+
+| | |
+|---------------------------------------------------------|----------------------|
+| GLOBAL INFORMATION INFRASTRUCTURE | Y.100-Y.999 |
+| INTERNET PROTOCOL ASPECTS | Y.1000-Y.1999 |
+| NEXT GENERATION NETWORKS | Y.2000-Y.2999 |
+| FUTURE NETWORKS | Y.3000-Y.3499 |
+| CLOUD COMPUTING | Y.3500-Y.3599 |
+| BIG DATA | Y.3600-Y.3799 |
+| QUANTUM KEY DISTRIBUTION NETWORKS | Y.3800-Y.3999 |
+| INTERNET OF THINGS AND SMART CITIES AND COMMUNITIES | Y.4000-Y.4999 |
+| General | Y.4000-Y.4049 |
+| Definitions and terminologies | Y.4050-Y.4099 |
+| Requirements and use cases | Y.4100-Y.4249 |
+| Infrastructure, connectivity and networks | Y.4250-Y.4399 |
+| Frameworks, architectures and protocols | Y.4400-Y.4549 |
+| Services, applications, computation and data processing | Y.4550-Y.4699 |
+| Management, control and performance | Y.4700-Y.4799 |
+| Identification and security | Y.4800-Y.4899 |
+| Evaluation and assessment | Y.4900-Y.4999 |
+
+*For further details, please refer to the list of ITU-T Recommendations.*
+
+# Recommendation ITU-T Y.4231
+
+## Requirements and capability framework of the Internet of things for vision
+
+## Summary
+
+Recommendation ITU-T Y.4231 provides requirements and capability framework of the Internet of things (IoT) for vision, a typical IoT for vision application workflow as well as some relevant IoT for vision use cases.
+
+With the popularization and development of smart cities and numerous IoT based verticals, the connotation of the Internet of things (IoT) is expanding and is no longer limited to simple sensor data collection and discrimination.
+
+The IoT for vision is one of the main development directions of the IoT which uses digital cameras and other types of sensors to perceive objects of interest (including human beings, vehicles, animals, etc.) for diverse applications based on appropriate analysis.
+
+## History \*
+
+| Edition | Recommendation | Approval | Study Group | Unique ID |
+|---------|----------------|------------|-------------|--------------------|
+| 1.0 | ITU-T Y.4231 | 2025-01-15 | 20 | 11.1002/1000/16026 |
+
+## Keywords
+
+Capability, IoT, requirement, sensors, vision application, visual sensors, workflow.
+
+---
+
+\* To access the Recommendation, type the URL in the address field of your web browser, followed by the Recommendation's unique ID.
+
+## FOREWORD
+
+The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, and information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis.
+
+The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics.
+
+The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1.
+
+In some areas of information technology which fall within ITU-T's purview, the necessary standards are prepared on a collaborative basis with ISO and IEC.
+
+## NOTE
+
+In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication administration and a recognized operating agency.
+
+Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words "shall" or some other obligatory language such as "must" and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party.
+
+## INTELLECTUAL PROPERTY RIGHTS
+
+ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process.
+
+As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents/software copyrights, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the appropriate ITU-T databases available via the ITU-T website at .
+
+© ITU 2025
+
+All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU.
+
+## Table of Contents
+
+| | Page |
+|--------------------------------------------------------|-------------|
+| 1 Scope ..... | 1 |
+| 2 References..... | 1 |
+| 3 Definitions ..... | 2 |
+| 3.1 Terms defined elsewhere..... | 2 |
+| 3.2 Terms defined in this Recommendation..... | 2 |
+| 4 Abbreviations and acronyms ..... | 2 |
+| 5 Conventions ..... | 3 |
+| 6 Overview of IoT for vision..... | 3 |
+| 7 Requirements of IoT for vision..... | 5 |
+| 7.1 Data acquisition..... | 5 |
+| 7.2 Data transmission ..... | 7 |
+| 7.3 Data analysis..... | 7 |
+| 7.4 Security and privacy ..... | 9 |
+| 7.5 Management ..... | 9 |
+| 8 Capability framework of IoT for vision..... | 10 |
+| 8.1 Application layer ..... | 10 |
+| 8.2 Service support and application support layer..... | 10 |
+| 8.3 Network layer ..... | 11 |
+| 8.4 Device layer..... | 12 |
+| 8.5 Security capabilities..... | 13 |
+| 9 Workflow of IoT for vision applications ..... | 13 |
+| Appendix I – Use cases of IoT for vision ..... | 15 |
+| I.1 Smart community applications..... | 15 |
+| I.2 Defect detection application in industries ..... | 15 |
+| I.3 Livestock applications ..... | 16 |
+| I.4 Autonomous driving..... | 16 |
+| Bibliography..... | 18 |
+
+
+
+# Recommendation ITU-T Y.4231
+
+## Requirements and capability framework of the Internet of things for vision
+
+# 1 Scope
+
+This Recommendation specifies the requirements and capability framework of the Internet of things (IoT) for vision, complementing the developments on common requirements and framework of the IoT in terms of vision-related systems. The requirements of the IoT for vision are independent of any specific application.
+
+The scope of this Recommendation includes:
+
+- requirements of IoT for vision;
+- capability framework of IoT for vision;
+- typical workflow of IoT for vision applications.
+
+Some relevant use cases of the Internet of things for vision are provided in the Appendix.
+
+# 2 References
+
+The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation.
+
+- | | |
+|------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------|
+| [ITU-T H.264] | Recommendation ITU-T H.264 (V15) (2024), Advanced video coding for generic audiovisual services . |
+| [ITU-T H.265] | Recommendation ITU-T H.265 (V10) (2024), High efficiency video coding . |
+| [ITU-T H.266] | Recommendation ITU-T H.266 (V3) (2023), Versatile video coding . |
+| [ITU-T M.3030] | Recommendation ITU-T M.3030 (2002), Telecommunications Markup Language (tML) framework . |
+| [ITU-T P.1202.2] | Recommendation ITU-T P.1202.2 (2013), Parametric non-intrusive bitstream assessment of video media streaming quality – Higher resolution application area . |
+| [ITU-T T.805] | Recommendation ITU-T T.805 (2012) ISO/IEC 15444-6:2013, Information technology – JPEG 2000 image coding system: Compound image file format . |
+| [ITU-T Y.4101] | Recommendation ITU-T Y.4101/Y.2067 (2017), Common requirements and capabilities of a gateway for Internet of things applications . |
+| [ITU-T Y.4113] | Recommendation ITU-T Y.4113 (2016), Requirements of the network for the Internet of things . |
+
+# 3 Definitions
+
+## 3.1 Terms defined elsewhere
+
+This Recommendation uses the following terms defined elsewhere:
+
+**3.1.1 access network** [b-ITU-T Q.1742.11]: A network that connects access technologies (such as a radio access network) to the core network.
+
+**3.1.2 core network** [b-ITU-T Y.101]: A portion of the delivery system composed of networks, systems equipment and infrastructures, connecting the service providers to the access network.
+
+**3.1.3 device** [b-ITU-T Y.4000]: With regard to the Internet of things, this is a piece of equipment with the mandatory capabilities of communication and the optional capabilities of sensing, actuation, data capture, data storage and data processing.
+
+**3.1.4 gateway** [ITU-T Y.4101]: A unit in the Internet of things which interconnects the devices with the communication networks. It performs the necessary translation between the protocols used in the communication networks and those used by devices.
+
+**3.1.5 Internet of things (IoT)** [b-ITU-T Y.4000]: A global infrastructure for the information society, enabling advanced services by interconnecting (physical and virtual) things based on existing and evolving interoperable information and communication technologies.
+
+NOTE 1 – Through the exploitation of identification, data capture, processing and communication capabilities, the IoT makes full use of things to offer services to all kinds of applications, whilst ensuring that the security and privacy requirements are fulfilled.
+
+NOTE 2 – From a broader perspective, the IoT can be perceived as a vision with technological and societal implications.
+
+## 3.2 Terms defined in this Recommendation
+
+None.
+
+# 4 Abbreviations and acronyms
+
+This Recommendation uses the following abbreviations and acronyms:
+
+| | |
+|------|------------------------------------------------------|
+| AI | Artificial Intelligence |
+| AVC | Advanced Video Coding |
+| BPP | Bit Per Pixel |
+| BPS | Bit Per Second |
+| CNN | Convolutional Neural Network |
+| CSV | Comma Separated Values |
+| DASH | Dynamic Adaptive Streaming over HTTP |
+| GPU | Graphics Processing Unit |
+| HAS | Hypertext Transfer Protocol Based Adaptive Streaming |
+| HDR | High Dynamic Range |
+| HEVC | High Efficiency Video Coding |
+| IMT | International Mobile Telecommunication |
+| IoT | Internet of Things |
+| JSON | JavaScript Object Notation |
+
+| | |
+|-------|----------------------------------------|
+| MJPEG | Motion Joint Photographic Expert Group |
+| ML | Machine Learning |
+| PaaS | Platform as a Service |
+| PII | Personally Identifiable Information |
+| QoS | Quality of Service |
+| RFID | Radio Frequency Identification |
+| VVC | Versatile Video Coding |
+| XML | Extensible Markup Language |
+
+# 5 Conventions
+
+In this Recommendation:
+
+The keywords "is required to" indicate a requirement which must be strictly followed and from which no deviation is permitted if conformance to this document is to be claimed.
+
+The keywords "is recommended" indicate a requirement which is recommended but which is not absolutely required. Thus, this requirement needs not be present to claim conformance.
+
+These terms are not intended to imply that the vendor's implementation must provide the option and the feature can be optionally enabled by the network operator/service provider. Rather, it means the vendor may optionally provide the feature and still claim conformance with the specification.
+
+# 6 Overview of IoT for vision
+
+An IoT for vision system is characterized by the use of digital cameras as the primary sensors complemented by other type of sensors in order to perceive objects of interest for diverse applications. It combines IoT, network, and artificial intelligence (AI) technologies to incorporate visual information and related services into the IoT and to support advanced visual applications. So that visual information can be timely and accurately acquired, transmitted and analysed. The IoT for vision system can receive the user instructions and achieve control of sensors and actuators. Since their conception, the usage of digital cameras in IoT deployment has continued to grow and today it is practically pervasive in almost all areas of life.
+
+IoT for vision plays an important role in smart cities, traffic crossroads, and the densely populated areas in the city centre of the main cities from all over the world have large numbers of cameras to capture visual information. However, the visual data are usually not well utilized, as a large amount of the visual data is stored in terminal devices, edge platform, and cloud platform for backup purposes. With AI technical development, the most important objects including pedestrians and vehicles can be detected for different tasks, thereby playing an important role in urban management and early warning. IoT for vision can assist in pedestrian and vehicle management and provide relevant information for possible traffic jams and subsequent measures.
+
+The following IoT technical components are identified to support IoT for vision systems, as shown in Figure 6-1:
+
+- Device [b-ITU-T Y.4000]: Visual sensors and other type of sensors are used for data acquisition. Visual sensors are the devices collecting visual raw data. Visual sensors include, but are not limited to, 2D cameras, 3D cameras, and point cloud cameras [b-Zahner].
+
+Visual sensors may be complemented by other sensors which can provide other information in support of the data analysis.
+
+NOTE 1 – Other sensors include, but are not limited to, global navigation satellite system (GNSS) sensors, radio frequency identification (RFID) sensors, infrared sensors, and pressure sensors. Due to
+
+the diversity of applications, the edge platform and the cloud platform may be utilised for data analysis of different types of data collected by a single type of sensor or multiple types of sensors working in collaboration for specific applications.
+
+- Gateway [ITU-T Y.4101]: The gateway may participate in data acquisition.
+- Network [ITU-T Y.4113]: It enables data transmission among sensors and IoT applications, and it is composed of access networks and a core network.
+- Edge platform [b-ITU-T F.743.12]: According to the IoT applications' requirements, it may perform data analysis processing at the network edge of visual and other sensor data before feeding the data to the cloud platform and/or IoT application server. It is powered by a scalable computing resource pool at the edge of the network to realize flexible, efficient, distributed and real-time computing services.
+
+NOTE 2 – For the sake of simplicity, in the IoT for vision system's components representation shown in Figure 6-1, edge devices, i.e., devices which process and transfer data at the network edge, are included in the edge platform.
+
+- Cloud platform: A platform which manages computing resource pools, including resources in the network. It may participate in data analysis and enable the IoT applications.
+- IoT application server [ITU-T Y.4113]: The IoT application server implements application logic according to the requirements of IoT for vision. It may include an edge IoT application server and a cloud IoT application server in terms of actual deployments.
+
+NOTE 3 – An edge IoT application server supports applications which have low time delay, low network bandwidth, and low computing resource requirements. A cloud IoT application server supports applications which have relatively high time delay, high network bandwidth, and high computing resource requirements.
+
+The IoT application server runs IoT applications and communicates with devices, gateways, edge platform and/or cloud platform via the network. It may participate in data analysis.
+
+NOTE 4 – With respect to Figure 6-1, the IoT for vision application flows are bidirectional.
+
+
+
+```
+
+graph LR
+ subgraph Device
+ subgraph Visual_sensors [Visual sensors]
+ 2D_camera[2D camera]
+ 3D_camera[3D camera]
+ Point_cloud_camera[Point cloud camera]
+ dots1[...]
+ end
+ subgraph Other_sensors [Other sensors]
+ RFID[RFID]
+ Infrared_sensor[Infrared sensor]
+ Pressure_sensor[Pressure sensor]
+ dots2[...]
+ end
+ end
+
+ Device --- Gateway[Gateway]
+ Gateway --- Network
+
+ subgraph Network
+ Access_network[Access network]
+ Core_network[Core network]
+ end
+
+ Network --- Edge_platform[Edge platform]
+ Network --- Cloud_platform[Cloud platform]
+ Edge_platform --- IoT_application_server[IoT application server]
+ Cloud_platform --- IoT_application_server
+
+```
+
+Figure 6-1: Overview of IoT for vision system architecture. The diagram shows a 'Device' block containing 'Visual sensors' (2D camera, 3D camera, Point cloud camera, ...) and 'Other sensors' (RFID, Infrared sensor, Pressure sensor, ...). The Device connects to a 'Gateway', which connects to a 'Network' block. The Network block contains an 'Access network' and a 'Core network'. The Network connects to an 'Edge platform' and a 'Cloud platform'. Both the Edge platform and the Cloud platform connect to an 'IoT application server'. The diagram is labeled Y.4231(25) in the bottom right corner.
+
+**Figure 6-1 – Overview of IoT for vision system**
+
+The IoT for vision system has the following key characteristics:
+
+- Support of high volume of data
+Data for vision includes images, 2D videos, 3D videos, point cloud and so on.
+
+- Unstructured data and structured data support
+The multimedia data such as images and videos captured by visual sensors is unstructured data, and the feature data used to represent various entities such as non-identifiable people, vehicles and objects, is structured data. The unstructured data and structured data are produced for further storage and analysis.
+NOTE 5 – Feature data is extracted from the raw data for intelligent analysis tasks, it can be classified by different formats and levels of processing.
+- Data processing and data analysis support
+The edge platform and cloud platform support a diverse set of machine learning (ML) algorithms for data processing and data analysis. The collaboration of edge platform and cloud platform may support the data processing and data analysis, e.g., for some services with specific time-delay requirements.
+- Edge computing and cloud computing technology support
+Visual data analysis is supported by edge computing and cloud computing technologies to perform machine learning (ML) model tasks.
+- Computer vision technology support
+IoT for vision utilizes computer vision technologies, especially ML technologies to process massive vision data from visual sensors for specific vision tasks.
+
+# **7 Requirements of IoT for vision**
+
+IoT for vision systems supports different IoT technical components, including device, gateway, network, edge platform, cloud platform and IoT application server. The subject of the requirements is identified based on the different technical components of the IoT for vision systems and the requirements can be classified into requirements for data acquisition, data transmission, data analysis, security and privacy, and management.
+
+## **7.1 Data acquisition**
+
+### **7.1.1 Basic requirements**
+
+- The devices of the IoT for vision system are required to have efficient lighting conditions according to the different application scenarios such as intelligent traffic management system, solid waste management, and water-level management. As the ML algorithm accuracy is highly related to the quality of videos and images, the lighting condition is an important factor affecting accuracy.
+- Visual sensors are required to support brightness anomaly diagnosis and restoration function, including brightness adjustment when the brightness is too high or too low, enhancement of whole or part of the image or video, and strong light suppression.
+- Visual sensors are required to support automatic adjustment of the high dynamic range (HDR) parameters according to the brightness change in the environment and to support the backlight compensation function to ensure that the monitoring object is clear and recognizable.
+- Visual sensors are required to have an identification for collaboration purposes.
+NOTE 1 – The information of visual sensors such as time and location, is useful for data analysis. This requirement is relevant for applications which involve the collection and analysis of data from multiple visual sensors. For example, a vehicle trajectory can be obtained by capturing the images and videos of the same vehicle from multiple visual sensors, each one with its own identification.
+- Visual sensors are required to upload the vision data on demand to the edge platform and/or cloud platform for intelligent analysis.
+
+- Visual sensors are recommended to support high or ultra-high resolution images and videos to satisfy the intelligent analysis.
+NOTE 2 – As an example, the pixels of video are usually 1080, 4K, or higher resolution pixels in industrial applications.
+- Visual sensors are recommended to support different kinds of lenses by the manufacturers to ensure a flexible and clear focus on the monitoring objects to cope with angles, occlusions, and various environmental backgrounds.
+NOTE 3 – The visual sensors need flexibility for enterprises and customers to choose different kinds of lenses.
+- Visual sensors are recommended to perform visual data compression before data is transmitted to the edge platform and/or cloud platform for intelligent analysis, alleviating the high data volume transmitted by the network.
+- Visual sensors are recommended to support basic data processing functions including cropping, padding, up-sampling, down-sampling, de-fogging, de-noising, and de-distorting [b-Park].
+- Visual sensors are recommended to support feature extraction methods including human-designed descriptors, preliminary vision features and semantic features for ML model tasks, including classification [b-Wang, S], object detection [b-Ren], instance segmentation [b-Ke], object tracking [b-Wang, Z], event detection [b-Ionescu], and action recognition [b-Gowda].
+- Visual sensors are recommended to support efficient and accurate video frame extraction and to capture the keyframes.
+- Visual sensors are recommended to upload the results of vision feature extraction to the edge platform and/or cloud platform for intelligent analysis.
+- Visual sensors are recommended to be complemented by additional information provided by other sensors, including GNSS information (longitude, latitude and height) and time information.
+- Visual sensors are recommended to respond to the requests involved with ML model tasks from other devices in the IoT for vision system.
+
+### 7.1.2 Codec requirements
+
+- Visual sensors are required to support at least one video related codec standard among the following ones for video support: H.264/Advanced video coding (AVC) [ITU-T H.264], H.265/High efficiency video coding (HEVC) [ITU-T H.265], H.266/Versatile video coding (VVC), motion joint photographic expert group (MJPEG) [ITU-T H.266].
+- Visual sensors are required to support image related codec as specified in [ITU-T T.805] for image support.
+- Visual sensors are recommended to support feature related codec and learning based codec as specified in, respectively, [b-MPEG-AI] and [b-JPEG-AI].
+- Visual sensors are recommended to support several codec levels and profiles from the requests of other devices in the system.
+- Visual sensors are recommended to record encoded time, bit per pixel (BPP), and bit per second (BPS).
+- Visual sensors are recommended to also transmit the recorded encoded time, bit per pixel (BPP) and bit per second (BPS) to the cloud platform for evaluating the codec performance.
+
+## **7.2 Data transmission**
+
+### **7.2.1 Basic requirements**
+
+The network is required to provide sufficient bandwidth of upstream rate in order to satisfy the maximum video bitrate and keyframes of the videos bitrate according to the application requirements.
+
+NOTE 1 – Keyframes focus on the obvious scene change (i.e., the main objects in the foreground have changed in the videos) and the interested object of interest appears in the camera. [b-Gawande]
+
+The network is required to support both wired and wireless access for supporting different application scenarios and time sensitive services. For services with low latency requirements, the access network is required to support different access modes, including optical fibre access, hybrid fibre, copper shaft access, and wireless access modes.
+
+The network is required to satisfy both time sensitive and time insensitive applications.
+
+- IoT for vision system is required to support both IPv4 and IPv6 protocols and addresses.
+- IoT for vision system is recommended to support different communication network technologies including the International Mobile Telecommunication (IMT) family and low-power wide-area network (LPWAN).
+- IoT for vision system is recommended to support capabilities to optimize resource allocation.
+
+NOTE 2 – [b-ITU-T Y.2501] provides an approach to optimize resource allocation by distributing computing, storage, network, and other resource information through the network control plane.
+
+### **7.2.2 QoS requirements**
+
+- The network is required to support different time sensitive applications.
+
+NOTE 1 – For time sensitive applications such as real-time or near real-time analysis applications, the edge computing devices may perform the whole data analysis, and the data analysis result is transmitted to the applications. For no time sensitive applications, data may be transmitted to the cloud platform in order to perform the data analysis. In the case of an edge platform with limited computing power, the data analysis may be divided in two parts, with the edge platform executing part of the analysis and the cloud platform executing the other part of the analysis.
+
+- The network is required to support different protocols regarding data stream technologies when dealing with network impairment recovery and repair, as well as data stream adjustment in response to network conditions changes.
+
+NOTE 2 – By monitoring network bandwidth and performance of visual sensors, and adopting appropriate coding algorithms, the quality and bit rate of video and image streams can be adjusted according to the changes in the network conditions. Common data stream technologies include dynamic adaptive streaming over HTTP (DASH) [b-ISO/IEC 23009-1] and hypertext transfer protocol based adaptive streaming (HAS) [b-OIPF-HTTP]. These technologies achieve more stable data streaming transmission by dynamically selecting the appropriate bitrate for the network environment.
+
+- The network is recommended to generate and implement appropriate quality of service (QoS) strategies according to the different service scenarios in terms of delay, jitter, sequence error and packet loss. For example, services with real-time control levels require low latency.
+
+## **7.3 Data analysis**
+
+### **7.3.1 Device identifier**
+
+- The IoT for vision system is required to support a unique identifier for devices including visual sensors and other sensors.
+
+NOTE 1 – Device identifier information is generated for reading, writing and storage.
+
+- The IoT for vision system is recommended to save the information associated with the device identifier in the cloud platform in a structured fashion.
+
+NOTE 2 – The IoT applications can use the cloud platform storage for device identifiers in the IoT for vision system databases and other databases (e.g., third party databases).
+
+### **7.3.2 Visual data analysis**
+
+#### **7.3.2.1 Basic requirements**
+
+- The cloud platform is required to support visual data analysis ability in image/video/audio format, including classification [b-Wang, S], object detection [b-Ren], instance segmentation [b-Ke], object tracking [b-Wang, S], event detection [b-Ionescu], action recognition [b-Gowda].
+- The cloud platform is recommended to support visual data analysis from multiple visual sensors, including visual data reconstruction to reconstruct the whole picture of the monitoring objects and events, and redundancy elimination to reduce the information related to irrelevant parts of the monitoring objects and events from neighbouring sensors.
+- The cloud platform is recommended to support visual data analysis based on the combination of visual sensor data and other types of sensor data such as radar data.
+
+#### **7.3.2.2 Visual data annotation requirements**
+
+- Visual data annotation is required to evaluate ML model accuracy.
+- Visual data annotation is required to support objects in the images and keyframes in the videos for assessing and training ML model accuracy.
+- Visual data annotation is recommended to support information including image/video ID, bounding boxes coordinate information, and image/video category ID.
+- Visual data annotation is recommended to use at least one of the following annotation formats: JavaScript object notation (JSON) [ITU-T P.1202.2], XML (extensible markup language) [ITU-T M.3030] and comma separated values (CSV).
+
+#### **7.3.2.3 Visual data analysis requirements**
+
+- The cloud platform is required to evaluate ML model performance before its deployment or during its operation.
+
+NOTE 1 – Examples of performance metrics of ML algorithms include:
+
+- Recall algorithms [b-Abhigyan]: evaluation metrics include mean absolute error (MAE), mean square error (MSE), root mean squared error (RMSE), and mean absolute percentage error (MAPE).
+- Classification algorithms [b-Wang, S]: evaluation metrics includes precision, recall, receiver operating characteristic (ROC), and area under curve (AUC).
+- Object detection/instance segmentation algorithms [b-Ren], [b-Ke]: evaluation metrics include mean average precision (mAP), average precision for small objects (APs), average precision for medium objects (APm), and average precision for large objects (APl).
+- The cloud platform is recommended to support ML algorithms of different applications for users to choose from.
+- The cloud platform is recommended to support common ML models and support third-party algorithm library to meet the service needs.
+
+NOTE 2 – Examples of common ML models include residual networks (ResNet) [b-He] and you only look once (YOLO) [b-Wang, C].
+
+- The cloud platform is recommended to support visual data analysis in real-time and/or non-real-time mode, for supporting different application scenarios and service requirements.
+
+## **7.4 Security and privacy**
+
+### **7.4.1 Data integrity requirements**
+
+- IoT for vision system is recommended to support verification mechanisms, encryption mechanisms, version control and access control to ensure the integrity of specific data in the acquisition process, storage process and transmission process, including but not limited to identification data, configuration data and visual data.
+
+### **7.4.2 Data confidentiality requirements**
+
+- IoT for vision system is recommended to support encryption, authentication and access control mechanisms to ensure the confidentiality of specific data in the acquisition, storage and transmission processes, including but not limited to identification data, configuration data and visual data.
+
+### **7.4.3 Data availability requirements**
+
+- IoT for vision system is recommended to support backup, recovery, and firewall mechanisms to ensure the availability of specific data in the acquisition, storing and transmission processes, including but not limited to identification data, configuration data and visual data.
+
+### **7.4.4 Data minimization requirements**
+
+- IoT for vision system is required to collect data only for the ML algorithms training and ML algorithms inference.
+
+NOTE – The data is not permitted to be collected for other purposes.
+
+### **7.4.5 Data retention requirements**
+
+- IoT for vision system is required to store the data in its internal databases and is not permitted to share it outside the system itself.
+- IoT for vision system is required to follow personally identifiable information (PII) protection rules.
+
+## **7.5 Management**
+
+### **7.5.1 Visual sensor management requirements**
+
+- Visual sensors are required to support registration/de-registration so end-users can log in and log out conveniently.
+
+NOTE 1 – The username and password are used when an end user logs into the device.
+
+- Visual sensors are required to support user authentication and authorization, and visual sensors are required to adopt different authentication methods.
+- Visual sensors are required to support remote version updates.
+- Visual sensors are required to support remote troubleshooting.
+- Visual sensors are required to have the function of querying the operation log.
+
+NOTE 2 – The operation log contains the entry records related to the user operations.
+
+- Visual sensors are required to support uploading the entry records to the log server or the monitoring management platform.
+- Visual sensors are required to support addressing allocation according to the security policy and management needs.
+- Visual sensors are recommended to support configurations for all devices such as capability parameters, performance parameters, service-related properties, status control parameters and monitoring parameters.
+
+### 7.5.2 Cloud platform management requirements
+
+- The cloud platform is required to support the separation of the authority of different users between administrator users and ordinary users.
+NOTE – Different user authorities cannot be managed interchangeably.
+- The cloud platform is required to limit the users with remote access rights according to the specific service needs.
+
+# 8 Capability framework of IoT for vision
+
+Based on the IoT reference model specified in [ITU-T Y.4000], Figure 8-1 illustrates the capability framework of IoT for vision, which consists of four layers and two cross-layer capability groups.
+
+In addition to capabilities specified in [ITU-T Y.4000], specific capabilities are required for the application layer, service support and application support layer, network layer, device layer, and the security capability group. These specific capabilities are shown in the blue highlighted rectangles in Figure 8-1.
+
+
+
+The diagram illustrates the capability framework of IoT for vision, structured into four layers and two cross-layer capability groups. The layers are: Application layer, Service support and application support layer, Network layer, and Device layer. The cross-layer capability groups are Management capability and Security capability. Specific capabilities are highlighted in blue rectangles within each layer.
+
+| Layer | Management capability | Security capability |
+|-----------------------------------------------|-------------------------------------------------------------------|------------------------|
+| Application layer | IoT for vision applications | |
+| Service support and application support layer | Visual data analysis capability Visual data storage capability | |
+| Network layer | Networking capabilities | Transport capabilities |
+| Device layer | Vision device capabilities | Gateway capabilities |
+
+Y.4231(25)
+
+Figure 8-1: The capability framework of the IoT for vision. The diagram shows a four-layer architecture with cross-layer capability groups.
+
+Figure 8-1 – The capability framework of the IoT for vision
+
+## 8.1 Application layer
+
+### 8.1.1 IoT for vision applications
+
+In support of the requirements described in clause 7.3, IoT for vision applications capabilities include, but are not limited to:
+
+- In a smart community environment, support of vehicle license plate detection and vehicle lane track record, pedestrian fall-down monitoring, and electric bicycle management.
+- In a smart industry environment, support of defect classification, defect location, robot guidance, object measurement, object sorting, and quality verification.
+- In a smart farm environment, support of animal number detection, animal position tracking, and motion recognition.
+
+## 8.2 Service support and application support layer
+
+### 8.2.1 Visual data analysis capabilities
+
+In support of the requirements described in clauses 7.3.1 and 7.3.2, visual data analysis capabilities include:
+
+- Support of ML model training and ML model evaluation.
+
+NOTE 1 – ML model training and evaluation takes place when the pre-set threshold of training datasets is satisfied.
+
+- Support of ML model weights updating and transmission to the edge platform, and iterative update of the model weights of the edge platform model.
+
+- Support of evaluating codec efficiency by machine vision model performance.
+
+NOTE 2 – The cloud platform can receive the reconstructed images/videos and then evaluate the model performance. The model performance can reflect the performance of the codec.
+
+- Support of the whole codec testing process in the platform.
+
+NOTE 3 – The testing process includes visual data input capability, coding capability, machine vision analysis capability, and result output capability. Visual data input capability is used to collect test images. Coding capability is used to encode the testing images obtained by the data input capability using the coding algorithms to be tested and decode the encoded images using the decoding algorithms to be tested to obtain the reconstructed images. Machine vision analysis capability is used to evaluate the performance of the ML model obtained by the coding capability and determine the accuracy of the analysis result.
+
+- Support of computing power management [b-ITU-T F.748.18], including different computing power techniques such as graphics processing unit (GPU) and platform as a service (PaaS).
+
+- Support of the computing power coordination between the cloud platform and the edge platform.
+
+NOTE 4 – The cloud platform mainly analyses the image streams while the edge platform mainly analyses the video streams and other relevant streams in order to have the appropriate allocation of computing power.
+
+- Support of algorithms evaluation capability to evaluate the performance of different algorithms.
+
+NOTE 5 – Multi-dimensional testing data are imported to evaluate the performance of the algorithms, via automated calculation through evaluation parameters and display in the form of a report.
+
+- Support of standardized access and interface output capabilities for intelligent video analysis algorithms.
+
+- Support of algorithm license dynamic authorization capability.
+
+- Support of video frame extraction capability for processing and analysis.
+
+- Support of flexible parameter set up to control the frequency, interval, and specific time period of frame extraction in order to obtain output image frames of high quality, high definition, and high accuracy for processing and analysis.
+
+### **8.2.2 Visual data storage capabilities**
+
+In support of requirements described in clauses 7.3.1 and 7.3.2, visual data storage capabilities include:
+
+- Support of images and videos storage.
+- Support of video frames and features storage.
+- Support of vision related supplementary data storage, including images and videos annotations, training and inference datasets updates.
+
+## **8.3 Network layer**
+
+### **8.3.1 Network capabilities**
+
+In support of the requirements described in clause 7.2, the network capabilities include:
+
+- Support of IPv4 and IPv6 dual stack to cope with devices and gateways supporting IPv4 and/or IPv6 technology.
+NOTE – The cloud platform manages the devices according to the corresponding IP protocol version and IP address.
+
+### 8.3.2 Transport capabilities
+
+In support of the requirements described in clause 7.2, the transport capabilities include:
+
+- Support of end-to-end video transmission QoS to meet the QoS service requirements.
+NOTE – IP bearer networks can achieve low latency, low jitter, and low packet loss rate when carrying end-to-end video and audio IP packet streams.
+- Support of transmission of different types of data streams including images, videos, features, and semantics data.
+- Support of control flow information transmission including device access control and resource control information.
+- Support of connections between devices (visual devices, sensing devices, gateways), edge platform and cloud platform, either wired or wireless depending on the types of devices connecting to the cloud platform.
+
+## 8.4 Device layer
+
+Device layer capabilities include vision device capabilities and gateway capabilities.
+
+### 8.4.1 Vision device capabilities
+
+In support of requirements in clauses 7.1.1 and 7.1.2, vision device capabilities include:
+
+- Support of visual data collection access control with different security strategies.
+- Support of visual data collection with different data formats, such as datasets, logs and files.
+- Support of collection of metadata sets.
+- Support of data packing and compression with multimedia data formats before the data transmission, and transmission of the packed and compressed data.
+- Support of local storage, cloud storage and a combination of local and cloud storage.
+- Support of data quality management and data model management.
+- Support of the capability of visual sensors, other sensors, and edge devices.
+- Support of the collection of images/videos to be detected and the transmission from the visual sensors.
+- Support of the extraction of features of images/videos to be detected and the flattening of the feature map [b-MPEG-AI].
+- Support of model inference, and results transmission to the service support and application support layer.
+NOTE 1 – Visual analysis model includes convolutional neural network (CNN) [b-Ren] and transformer visual network [b-Vaswani].
+- Support of distributed computing.
+NOTE 2 – Distributed computing refers to a system where processing and data storage is distributed across multiple devices or systems, rather than being handled by a single central device. In a distributed system, each device or system has its own processing capabilities and may also store and manage its own data. These devices or systems work together to perform tasks and share resources, with no single device serving as the central hub. [b-Distributed computing].
+- Support of the completion of the ML tasks with the cloud platform jointly.
+
+NOTE 3 – The edge platform extracts the features from the collected images with the feature extraction layers of the ML network model [b-MPEG-AI] and sends the extracted features to the cloud platform. The cloud platform decodes the features and makes inferences on the decoded features with the other layers of the same ML network model, to output the predicted results, such as the object classes and position.
+
+- Support of the reception of the ML tasks result from other devices such as the position of the detected objects in the image and further interaction with the sending equipment.
+
+NOTE 4 – Edge platform extracts the area specific images from the result received from the cloud platform and returns the area specific images to the sending equipment.
+
+- Support of standardized video networking protocols, such as ONVIF [b-ONVIF] protocol, to access the visual sensors.
+
+### **8.4.2 Gateway capabilities**
+
+In support of the requirements in clause 7.1, the gateway capabilities include:
+
+- Support of device management, communication management, data storage, data processing, data dispatching, and service management as described in [ITU-T Y.4101].
+
+## **8.5 Security capabilities**
+
+In support of the requirements in clause 7.4, the security capabilities include:
+
+- Support of encryption mechanisms and verification mechanisms for personal information and other sensitive data.
+
+NOTE 1 – Capabilities with encryption support, include but are not limited to key generation, key storage, certificate management and firewall.
+
+In addition, in terms of device layer, the security capabilities also include:
+
+- Support of equipment access protection and security of devices, including password security, security updates, vulnerability disclosure, secure development, PII protection, attack defence, hardware, and interface security.
+
+In terms of the network layer, the security capabilities also include:
+
+- Support of network security and network boundary protection.
+
+In terms of application and service support layer, the security capabilities also include:
+
+- Support of security of the operating environment, application security, security of the used AI techniques and data security.
+
+NOTE 2 – In computer software, an operating environment or integrated applications environment is the environment in which users run the application software. The environment consists of a user interface provided by an applications manager and usually an application programming interface to the applications manager [b-Operating environment].
+
+# **9 Workflow of IoT for vision applications**
+
+Figure 9-1 shows a typical IoT for vision application workflow, which is the workflow of the "abnormality recognition" application.
+
+NOTE – The principle of the model inference and model training can be applied to many IoT for vision applications.
+
+The workflow includes the collaboration of visual sensors, edge platform, cloud platform and IoT for vision applications, which can effectively utilize the network bandwidth and the computing power of edge and cloud platforms, effectively shorten the ML task processing time and improve the computing efficiency.
+
+In addition, the ML model deployed on the edge platform uses the scene data transmitted by the visual sensor for model inference, the ML model is also deployed on the cloud platform for model training, so that the model parameters can be updated in real time according to the scene data, thus improving the model accuracy.
+
+
+
+```
+
+sequenceDiagram
+ participant IoT as IoT for vision application
+ participant Cloud as Cloud platform
+ participant Edge as Edge platform
+ participant Sensors as Visual sensors
+
+ IoT->>Cloud: Service call request
+ activate Cloud
+ Cloud->>Cloud: Authentication and authorization
+ deactivate Cloud
+ Cloud->>Edge: Service call request
+ activate Edge
+ Edge->>Edge: Authentication and authorization
+ deactivate Edge
+ Edge->>Sensors: Service call request
+ activate Sensors
+ Sensors->>Sensors: Collect images/videos
+ deactivate Sensors
+ Sensors->>Edge: Images/videos to be detected
+ deactivate Sensors
+ activate Edge
+ Edge->>Edge: Model inference
+ deactivate Edge
+ Edge->>IoT: Normal results
+ deactivate Edge
+ Edge->>Cloud: Abnormal results
+ deactivate Edge
+ Edge->>Cloud: Images/videos to be detected
+ deactivate Edge
+ activate Cloud
+ Cloud->>Cloud: Model training
+ deactivate Cloud
+ Cloud->>Edge: Model weights information
+ deactivate Cloud
+ activate Edge
+ Edge->>Edge: Model weights updating
+ deactivate Edge
+ deactivate IoT
+
+```
+
+Y.4231(25)
+
+Sequence diagram showing the abnormality recognition application workflow between IoT for vision application, Cloud platform, Edge platform, and Visual sensors.
+
+**Figure 9-1 – Abnormality recognition application workflow**
+
+- 1) The IoT for vision application (i.e., the abnormality recognition application) sends the service call request to the cloud platform, edge platform and visual sensors after authentication and authorization.
+- 2) The edge platform receives the images/videos to be detected sent by the visual sensors, deploys an appropriate ML model and performs abnormal recognition. The ML model in the edge platform is used to calculate the abnormality categories and location information. When the abnormality recognition result shows that the images/videos to be detected belong to an abnormal category, the images/videos to be detected are sent to the cloud platform so that the cloud platform can use the images/videos to train the preset abnormality recognition ML model. When the images/videos to be detected do not belong to the abnormality categories, the recognition result is sent to the application side.
+- 3) After the cloud platform receives the abnormal images/videos, the cloud platform is configured to annotate the images/videos which are identified as abnormal by the edge platform, store the images/videos in the training datasets, and use the training datasets to train the preset abnormality recognition ML model. When the performance of the trained abnormality recognition ML model is better than the preset performance threshold, the cloud platform will send the current model weights information of the abnormality recognition ML model to the edge platform.
+
+# Appendix I
+
+## Use cases of IoT for vision
+
+(This appendix does not form an integral part of this Recommendation.)
+
+## I.1 Smart community applications
+
+In the community, it is difficult to park, and the access of outsiders has always been the two pain points of community management. At present, the community generally uses the automatic identification system of the community road gate, which includes the monitoring camera and the ground sensor coil to realize the automatic identification of vehicles. Through the deployment of cameras, ground sensing coils and infrared sensors in the community, community vehicle management, and personnel management are realized.
+
+The IoT for vision system will have great advantages in the community management, through 2D cameras, point cloud cameras, and sensors to assist in data collection, transmission and analysis. Users can view the use of the parking lots through applications or mobile phones, and community managers can manage the parking spaces in the community.
+
+
+
+Illustration of a smart community parking system. A smartphone screen displays a 3D isometric view of a parking lot. Several cars (red, blue, yellow) are parked in designated spaces marked with 'P' signs. A green bus is also visible. The scene includes trees, a blue sky, and various IoT-related icons like a Wi-Fi symbol, a location pin, and a camera icon, suggesting a smart, connected environment.
+
+Figure I.1 – Parking spaces in smart community
+
+## I.2 Defect detection application in industries
+
+Industrial defect detection based on IoT for vision is a system that uses machines or computers to replace human vision for detection, classification, measurement or judgment in industries. Industrial defect detection systems based on IoT for vision can be used in defect detection, defect location and other fields.
+
+The IoT for vision system converts industrial products into image signals through the visual acquisition end and transmits them to the image processing system at the edge end. The image system performs various calculations on these data and signals to extract the features of the target, and then controls the equipment actions at the industrial site according to the discrimination results. The cloud platform is used for model training and model iteration. A defect detection system based on IoT for vision has a very important value in the industrial defect detection, classification, industrial dimension measurement and other fields.
+
+
+
+Diagram of a defect detection system in an industrial setting. A conveyor belt moves several blue blocks. A camera unit above the belt projects a yellow light cone onto one of the blocks. A control panel to the right shows three status indicators: the first with an 'X', the second with a checkmark, and the third with an 'X'.
+
+**Figure I.2 – Defect detection in industries**
+
+## **I.3 Livestock applications**
+
+With the development of urbanization, animal breeding has become more and more specialized. Generally, farmers have a large number of animals such as cows and sheep in vast areas. The IoT for vision can be used for intelligent functions such as animal number detection, animal position tracking, and motion recognition.
+
+In the traditional way, farmers need to check the number of animals when they leave and enter the fence. With the deployment of visual sensors and networks, data can be easily transmitted to the edge platform and cloud platform to calculate the number of animals. By installing visual sensors on the electronic fence and grass, animals can be recognized in real time with high accuracy. In addition, if animals cross the specified area, there may be security problems. Through the IoT for vision, farmers can take measures to protect them from theft. In addition, monitoring of animal growth, animal environment, and grassland degradation can be performed.
+
+
+
+Diagram of smart livestock detection. Four cameras are positioned around a group of cows. Arrows from each camera point towards the cows, indicating the field of view for detection.
+
+**Figure I.3 – Smart livestock detection**
+
+## **I.4 Autonomous driving**
+
+In the autonomous driving system, cars may need to communicate with each other and other sensors to perform different tasks, such as lane detection, pedestrian detection, etc. The sensors in the infrastructure can transmit videos, images, and point cloud data to different vehicles, and these vehicles can use these videos, images, and point cloud data to perform intelligent tasks.
+
+
+
+A night-time illustration of an autonomous vehicle (a white car) at a city intersection. The vehicle is surrounded by other vehicles, including a bus and several cars, and pedestrians. The scene is overlaid with a complex network of colored lines (red, green, yellow, blue) representing the vehicle's sensor range and data processing, illustrating the concept of autonomous driving. The lines radiate from the white car, connecting to various points on the other vehicles and pedestrians, symbolizing the vehicle's perception and decision-making process.
+
+A night-time illustration of an autonomous vehicle (a white car) at a city intersection, surrounded by other vehicles and pedestrians. The scene is overlaid with a complex network of colored lines (red, green, yellow, blue) representing the vehicle's sensor range and data processing, illustrating the concept of autonomous driving.
+
+**Figure I.4 – Autonomous driving**
+
+# Bibliography
+
+- [b-ITU-T F.743.12] Recommendation ITU-T F.743.12 (2021), *Requirements for edge computing in video surveillance*.
+- [b-ITU-T F.748.18] Recommendation ITU-T F.748.18 (2022), *Metric and evaluation methods for AI-enabled multimedia application computing power benchmark*.
+- [b-ITU-T Q.1742.11] Recommendation ITU-T Q.1742.11 (2014), *IMT 2000 references (approved as of 31 December 2012) to ANSI-41 evolved core network with cdma2000 access network*.
+- [b-ITU-T Y.101] Recommendation ITU-T Y.101 (2000), *Global Information Infrastructure terminology: Terms and definitions*.
+- [b-ITU-T Y.2501] Recommendation ITU-T Y.2501 (2021), *Computing power network – Framework and architecture*.
+- [b-ITU-T Y.4000] Recommendation ITU-T Y.4000/Y.2060 (2012), *Overview of the Internet of things*.
+- [b-ISO/IEC 23009-1] ISO/IEC 23009-1:2022, *Information technology – Dynamic adaptive streaming over HTTP (DASH) – Part 1: Media presentation description and segment formats*.
+<>
+- [b-Abhigyan] Abhigyan (2020), *Problems with Precision and Recall*. Analytics Vidhya.
+<>
+- [b-Distributed computing] *What is Distributed Computing?* (2025). Geeks for Geeks.
+< >
+- [b-Gowda] Gowda, S.N., Rohrbach, M., and Sevilla-Lara, L. (2021), *SMART Frame selection for action recognition*. Proceedings of the AAAI Conference on Artificial Intelligence. Volume 35, No. 2, pp. 1451-1459).
+<>
+- [b-Gawande] Gawande, U., Hajari, K., and Golhar, Y. (2020), *Deep Learning Approach to Key Frame Detection in Human Action Videos*. Recent Trends in Computational Intelligence.
+<>
+- [b-He] He, K., Zhang, X., Ren, S., and Sun, J. (2016), *Deep Residual Learning for Image Recognition*. IEEE Xplore®.
+<>
+- [b-Ionescu] Ionescu, R.T., Smeureanu, S., Alexe, B., and Popescu, M. (2017), *Unmasking the abnormal events in video*. arXiv:1705.08182
+<>
+- [b-JPEG-AI] ISO/IEC JTC 1/SC29/WG1 N100600, CPM. (2023), *JPEG AI Common Training and Test Conditions, 100th Meeting, Covilhã*.
+<[https://ds.jpeg.org/documents/jpegai/wg1n100600-100-CPM-JPEG\\_AI\\_Common\\_Training\\_&\\_Test\\_Conditions\\_v8\\_0.pdf](https://ds.jpeg.org/documents/jpegai/wg1n100600-100-CPM-JPEG_AI_Common_Training_&_Test_Conditions_v8_0.pdf)>
+
+- [b-Ke] Ke, L., Tai, Y-W., and Tang, C-K. (2021), *Deep occlusion-aware instance segmentation with overlapping biLayers*. arXiv:2103.12340. <>
+- [b-MPEG-AI] MPEG-AI. (2025), Part: 2, *Video coding for machines*. < >
+- [b-OIPF-HTTP] OIPF Release 2 Specification. (2010), *HTTP adaptive streaming [V2.0]*. <[https://www.oipf.tv/docs/oipf-archive/OIPF-T1-R2-Specification-Volume-2a-HTTP-Adaptive-Streaming-V2\\_0-2010-09-07.pdf](https://www.oipf.tv/docs/oipf-archive/OIPF-T1-R2-Specification-Volume-2a-HTTP-Adaptive-Streaming-V2_0-2010-09-07.pdf)>
+- [b-ONVIF] ONVIF™ (2024), *ONVIF Core Specification – Version 24.12*. <>
+- [b-Operating environment] Operating Environment. <>
+- [b-Park] Park, J., Byun, S-C., and Lee, B-U. (2009), *Lens distortion correction using ideal image coordinates*. IEEE Transactions on Consumer Electronics, Volume: 55, Issue: 3, pp. 987 – 991. <>
+- [b-Ren] Ren, S., He, K., Girshick, R., and Sun, J. (2015), *Faster R-CNN: Towards real-time object detection with region proposal networks*. <>
+- [b-Vaswani] Vaswani, A., Shazeer, N., Parmar, N., Uszkoreit, J., Jones, L., Gomez, A.N., Kaiser, Ł., Polosukhin, I. (2017), *Advances in neural information processing systems 30* (NIPS 2017). Attention is all you need. <[https://papers.nips.cc/paper\\_files/paper/2017/hash/3f5ee243547dee91fbd053c1c4a845aa-Abstract.html](https://papers.nips.cc/paper_files/paper/2017/hash/3f5ee243547dee91fbd053c1c4a845aa-Abstract.html)>
+- [b-Wang, S] Wang, S., and Su, Z. (2019), *Metamorphic testing for object detection systems*. arXiv:1912.12162. <>
+- [b-Wang, Z] Wang, Z., Zheng, L., Liu, Y., Li, Y., and Wang, S. (2019), *Towards real-time multi-object tracking*. arXiv:1909.12605. <>
+- [b-Wang, C] Wang, C.Y., Yeh, I.H., and Liao, H.Y.M. (2024), *YOLOv9: Learning what you want to learn using programmable gradient information*. arXiv preprint arXiv:2402.13616. <>
+- [b-Zahner] Zahner, J., and Soulje, N. (2018), *Point Cloud Management: An Overview of Current Practices and Technology*. <[https://www.nist.gov/system/files/documents/2019/04/08/16d\\_point\\_cloud\\_management\\_-\\_jesse\\_zahner.pdf](https://www.nist.gov/system/files/documents/2019/04/08/16d_point_cloud_management_-_jesse_zahner.pdf)>
+
+
+
+
+
+## SERIES OF ITU-T RECOMMENDATIONS
+
+| | |
+|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------|
+| Series A | Organization of the work of ITU-T |
+| Series D | Tariff and accounting principles and international telecommunication/ICT economic and policy issues |
+| Series E | Overall network operation, telephone service, service operation and human factors |
+| Series F | Non-telephone telecommunication services |
+| Series G | Transmission systems and media, digital systems and networks |
+| Series H | Audiovisual and multimedia systems |
+| Series I | Integrated services digital network |
+| Series J | Cable networks and transmission of television, sound programme and other multimedia signals |
+| Series K | Protection against interference |
+| Series L | Environment and ICTs, climate change, e-waste, energy efficiency; construction, installation and protection of cables and other elements of outside plant |
+| Series M | Telecommunication management, including TMN and network maintenance |
+| Series N | Maintenance: international sound programme and television transmission circuits |
+| Series O | Specifications of measuring equipment |
+| Series P | Telephone transmission quality, telephone installations, local line networks |
+| Series Q | Switching and signalling, and associated measurements and tests |
+| Series R | Telegraph transmission |
+| Series S | Telegraph services terminal equipment |
+| Series T | Terminals for telematic services |
+| Series U | Telegraph switching |
+| Series V | Data communication over the telephone network |
+| Series X | Data networks, open system communications and security |
+|