File size: 3,758 Bytes
e71f38d
74e78ad
0baf24f
74e78ad
0baf24f
 
74e78ad
0baf24f
74e78ad
0baf24f
 
 
e71f38d
74e78ad
0baf24f
e71f38d
74e78ad
0baf24f
e71f38d
74e78ad
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
 
0baf24f
e71f38d
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
0 to 70% (vs. fixed speed) while reducing installation time.

<|ref|>image<|/ref|><|det|>[[54, 241, 405, 518]]<|/det|>

<|ref|>title<|/ref|><|det|>[[55, 531, 197, 542]]<|/det|>
# SPECIFICATIONS

<|ref|>table<|/ref|><|det|>[[55, 548, 488, 953]]<|/det|>

<table><tr><td>Indoor enclosures</td><td>IP20 Open, TYPE 1, TYPE 12</td></tr><tr><td>Outdoor enclosures</td><td>TYPE 3R, TYPE 4X</td></tr><tr><td>Input supply</td><td>1.5-600 hp (frame A-D) wall or base mounted</td></tr><tr><td>Ambient<br>temperature</td><td>\(14^{\circ }F-113^{\circ }F(-10^{\circ }C-45^{\circ }C)\) Higher temperatures can be achieved<br>by derating the output amperage of<br>the drive 10% for up to 122掳F(50掳C)</td></tr><tr><td>Communication</td><td>Modbus庐 RTU, Metasys N2, FLN, and BACnet standard<br>Others available with option cards</td></tr><tr><td>Altitudes</td><td>At altitudes from 0 to 1,000 meters<br>(0 to 3,300 ft)<br>Nameplate rated current is available<br>Derate for altitudes above 1,000<br>(3,300 ft) with a maximum operating<br>altitude of 3,000 m(9,900 ft)<br>Consult factory for applications above<br>3,000 m(9,900 ft)</td></tr><tr><td>Relative humidity</td><td>Lower than 95% without condensation</td></tr><tr><td>Electrical -<br>input power</td><td>3 phase 380 V to 480 V卤10%<br>1 phase 200 V to 240 V卤10%<br>3 phase 200 V to 240 V卤10%<br>3 phase 525 V to 600 V卤10%<br>Frequency 50 or 60 Hz,卤2 Hz</td></tr><tr><td>Electrical -<br>output power</td><td>3 phase from 0 to V supply</td></tr></table>

<|ref|>title<|/ref|><|det|>[[510, 310, 752, 384]]<|/det|>
# AQUAVAR庐 IPC VARIABLE SPEED CONTROLLER

<|ref|>title<|/ref|><|det|>[[510, 433, 598, 444]]<|/det|>
# FEATURES

<|ref|>text<|/ref|><|det|>[[512, 456, 925, 486]]<|/det|>
路Easier start-up and programming with Start-Up Genie

<|ref|>text<|/ref|><|det|>[[512, 475, 888, 504]]<|/det|>
路Wide range of standard and permanent magnet motors with power up to 600 hp

<|ref|>text<|/ref|><|det|>[[512, 512, 935, 541]]<|/det|>
路Multi-pump configuration for up to four (4) pumps - no need for programmable logic controller (PLC)

<|ref|>text<|/ref|><|det|>[[512, 549, 890, 576]]<|/det|>
路Remote commissioning and monitoring with USB connectivity and software

<|ref|>text<|/ref|><|det|>[[512, 584, 928, 595]]<|/det|>
路Two wire multi-pump connection for faster installation

<|ref|>text<|/ref|><|det|>[[512, 605, 917, 649]]<|/det|>
路Hand on, off, and auto-on buttons available for easy pump operation at the keypad. No toggling between local and remote operation

<|ref|>text<|/ref|><|det|>[[512, 658, 939, 684]]<|/det|>
路System redundancy with multi-master control in case of drive failure

<|ref|>text<|/ref|><|det|>[[512, 693, 922, 721]]<|/det|>
路BACnet and Modbus as a standard for seamless BMS integration

<|ref|>text<|/ref|><|det|>[[512, 730, 859, 743]]<|/det|>
路Submersible and above ground applications

<|ref|>text<|/ref|><|det|>[[512, 751, 864, 764]]<|/det|>
路Wide range of voltage and enclosure options

<|ref|>text<|/ref|><|det|>[[512, 773, 680, 784]]<|/det|>
路True 208 V coverage

<|ref|>text<|/ref|><|det|>[[512, 794, 747, 806]]<|/det|>
路Dedicated single phase input

<|ref|>text<|/ref|><|det|>[[512, 815, 891, 842]]<|/det|>
路Remote commissioning and monitoring with USB connectivity and software

<|ref|>text<|/ref|><|det|>[[512, 850, 891, 863]]<|/det|>
路In-panel or handheld keypad with backlit display

<|ref|>text<|/ref|><|det|>[[512, 872, 910, 884]]<|/det|>
路Alarm Log for last 5 alarms and maintenance events

<|ref|>text<|/ref|><|det|>[[512, 892, 905, 920]]<|/det|>
路EMC/RFI filters and dual DC-link reactors to reduce drive noise emissions and interference

<|ref|>text<|/ref|><|det|>[[512, 929, 858, 957]]<|/det|>
路I/O expansion cards, factory installed or field configured