f0ec570 0713efa | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 | ---
license: mit
---
# PowerDiT Dataset
This repository contains processed power-system graph data for machine learning experiments on power-flow- and optimal-power-flow-related tasks.
The data is generated with [**gridfm-datakit**](https://github.com/gridfm/gridfm-datakit) based on benchmark grid cases from [**PGLib**](https://github.com/power-grid-lib/pglib-opf), and then preprocessed into graph-structured samples.
It is intended to be stored in the folders examples/data_processed/pf and examples/data_processed/opf.
## Overview
The dataset consists of graph representations of electric power systems under a range of operating conditions and perturbations.
Each sample corresponds to a power-grid state derived from a benchmark network case, with:
- **nodes** representing buses
- **edges** representing transmission lines
- **node features** encoding electrical state, bus metadata, and generator properties.
- **edge features** encoding electrical line parameters.
The data is split into two different datasets:
- **PF mode (Power Flow)**
The samples are merely physically (power-flow) consistent with non-cost-optimal generations.
- **OPF mode (Optimal Power Flow)**
The samples are creating using an opf-solver such that generator setpoints are cost-optimal.
## Available data
The processed dataset currently includes the following grid cases and sample counts:
| grid | #buses | #gens | #lines | pf samples | opf samples |
|---|---:|---:|---:|---:|---:|
| case3_lmbd | 3 | 3 | 6 | 1,224,988 | 934,045 |
| case5_pjm | 5 | 5 | 12 | 1,287,400 | 1,214,688 |
| case14_ieee | 14 | 5 | 40 | 1,290,095 | 1,300,186 |
| case24_ieee_rts | 24 | 33 | 76 | 1,290,126 | 1,301,982 |
| case30_ieee | 30 | 6 | 82 | 1,300,680 | 1,296,767 |
| case30_as | 30 | 6 | 82 | 1,300,200 | 1,284,562 |
| case39_epri | 39 | 10 | 92 | 1,300,211 | 1,301,635 |
| case57_ieee | 57 | 7 | 160 | 1,301,222 | 1,273,026 |
| case60_c | 60 | 23 | 176 | 1,302,069 | 1,300,858 |
| case73_ieee_rts | 73 | 99 | 240 | 1,300,405 | 1,301,531 |
| case89_pegase | 89 | 12 | 420 | 654,591 | 1,483,225 |
| case118_ieee | 118 | 54 | 372 | 1,300,742 | 1,301,781 |
| case162_ieee_dtc | 162 | 12 | 568 | 1,046,318 | 181,038 |
| case179_goc | 179 | 29 | 526 | 1,293,617 | 739,821 |
| case197_snem | 197 | 35 | 572 | 1,301,323 | 1,391,101 |
| case200_activ | 200 | 49 | 490 | 1,301,480 | 1,320,560 |
| case240_pserc | 240 | 143 | 896 | 1,011,541 | 260,102 |
| case300_ieee | 300 | 69 | 822 | 1,067,772 | 625,028 |
| case500_goc | 500 | 224 | 1,466 | 1,018,707 | 543,710 |
| case588_sdet | 588 | 167 | 1,372 | 1,427,568 | 622,209 |
| case793_goc | 793 | 214 | 1,826 | 1,414,878 | 405,521 |
## What the data consists of
At a high level, the dataset contains:
- benchmark power-grid topologies
- sampled and perturbed operating conditions
- simulated physical solutions
- graph-structured representations for ML
### Node features
| # | Feature | Name | PF-PQ | PF-PV | PF-REF | OPF-PQ | OPF-PV | OPF-REF | SE-PQ | SE-PV | SE-REF |
|---:|---|---|:---:|:---:|:---:|:---:|:---:|:---:|:---:|:---:|:---:|
| 0 | P_d | Active load demand | I | I | I | I | I | I | M | M | M |
| 1 | Q_d | Reactive load demand | I | I | I | I | I | I | M | M | M |
| 2 | Q_g | Reactive generation | I | O | O | I | O | O | M | M | M |
| 3 | V_m | Voltage magnitude | O | I | O | O | O | O | M | M | M |
| 4 | V_a | Voltage angle | O | O | I | O | O | I | O | O | O |
| 5 | PQ flag | PQ bus indicator | I | I | I | I | I | I | I | I | I |
| 6 | PV flag | PV bus indicator | I | I | I | I | I | I | I | I | I |
| 7 | REF flag | Slack bus indicator | I | I | I | I | I | I | I | I | I |
| 8 | V_m^min | Min. voltage magnitude | -- | -- | -- | I | I | I | I | I | I |
| 9 | V_m^max | Max. voltage magnitude | -- | -- | -- | I | I | I | I | I | I |
| 10 | Q_g^min | Min. reactive generation | -- | -- | -- | I | I | I | I | I | I |
| 11 | Q_g^max | Max. reactive generation | -- | -- | -- | I | I | I | I | I | I |
| 12 | G_s | Shunt conductance | -- | -- | -- | I | I | I | I | I | I |
| 13 | B_s | Shunt susceptance | -- | -- | -- | I | I | I | I | I | I |
| 14 | V_n (kV) | Nominal voltage | -- | -- | -- | I | I | I | I | I | I |
### Generator features
| # | Feature | Name | PF-PQ/PV | PF-REF | OPF | State Est. |
|---:|---|---|:---:|:---:|:---:|:---:|
| 0 | P_g | Active generation | I | O | O | M |
| 1 | P_g^min | Min. active generation | -- | -- | I | I |
| 2 | P_g^max | Max. active generation | -- | -- | I | I |
| 3 | c_0 | Cost constant term | -- | -- | I | I |
| 4 | c_1 | Cost linear coefficient | -- | -- | I | I |
| 5 | c_2 | Cost quadratic coefficient | -- | -- | I | I |
### Edge features
| # | Feature | Name | Power Flow | OPF | State Est. |
|---:|---|---|:---:|:---:|:---:|
| 0 | P_e | Active power flow | O | O | M |
| 1 | Q_e | Reactive power flow | O | O | M |
| 2 | Y_ff,r | From-from admittance (real) | I | I | I |
| 3 | Y_ff,i | From-from admittance (imag.) | I | I | I |
| 4 | Y_ft,r | From-to admittance (real) | I | I | I |
| 5 | Y_ft,i | From-to admittance (imag.) | I | I | I |
| 6 | tap | Transformer tap ratio | I | I | I |
| 7 | theta_min | Min. angle difference | -- | I | I |
| 8 | theta_max | Max. angle difference | -- | I | I |
| 9 | rate_A | Thermal rating (MVA) | -- | I | I |
- I = input feature
- O = output / target feature
- M = measured feature
- -- = not used
## Data source
The samples have been generated using **Gridfm-datakit** on the [**Future Technologies Partition**](https://www.nhr.kit.edu/userdocs/ftp/) on four intel sapphire rapids nodes.
The underlying network cases (topologies and initial load and generation profiles) are based on **PGLib** benchmark systems, the perturbation framework is **Gridfm-datakit**.
The preprocessing from **Gridfm-graphkit** has been adapted to allow for larger dataset sizes.
## Perturbations applied during data generation
The data generation process in **gridfm-datakit** applies perturbations to create diverse operating conditions and topologies.
The perturbation types include:
### 1. Load perturbations
Load levels are randomly varied using a global scaling factor and local noise.
### 2. Topology and admittance perturbations
N-k perturbations are used to randomly cut off buses or edges. We used k=1.
Further, the resistance and reactance parameters are randomly scaled during the perturbation process.
### 3. Generation perturbations
The generators are perturbed by changing their cost coefficients. In OPF-mode, the generator setpoints are recalculated with an opf-solver
after topology and load perturbations have been applied. In PF-mode, an OPF-solver is only used BEFORE the perturbations.
## Preprocessing
The raw power-system scenarios are preprocessed into a disk-backed heterogeneous graph format for efficient training and random access.
### Raw inputs
The preprocessing pipeline starts from three parquet tables per dataset split:
- `bus_data.parquet`
- `gen_data.parquet`
- `branch_data.parquet`
Each row belongs to a specific `scenario`, and each scenario corresponds to one graph sample.
### Scenario validation and filtering
Before graph construction, scenarios are validated for structural consistency.
In particular, scenarios are removed if their bus indices are invalid, i.e. if:
- bus IDs are duplicated, or
- bus IDs are not consecutive from `0` to `N-1`
This ensures that each scenario can be converted into a well-formed graph with a consistent node indexing scheme.
### Feature extraction
The preprocessing selects fixed feature subsets for buses, generators, and branches.
#### Bus features
Bus node features include electrical state, bus type indicators, and operating constraints:
- `Pd`, `Qd`
- `Qg`, `Vm`, `Va`
- `PQ`, `PV`, `REF` flags
- `min_vm_pu`, `max_vm_pu`
- `min_q_mvar`, `max_q_mvar`
- `GS`, `BS`
- `vn_kv`
#### Generator features
Generator node features include operating quantities and cost parameters:
- `p_mw`
- `min_p_mw`, `max_p_mw`
- `cp0_eur`, `cp1_eur_per_mw`, `cp2_eur_per_mw2`
- `in_service`
#### Branch features
Branch edge features include power-flow quantities, admittance terms, and branch constraints.
For each physical branch, the preprocessing creates **two directed edges**:
- one forward edge (`from_bus -> to_bus`)
- one reverse edge (`to_bus -> from_bus`)
The forward and reverse edges receive direction-specific attributes, e.g.:
- forward: `pf`, `qf`, `Yff_*`, `Yft_*`
- reverse: `pt`, `qt`, `Ytt_*`, `Ytf_*`
Shared branch attributes include:
- `tap`
- `ang_min`, `ang_max`
- `rate_a`
- `br_status`
### Bus-level aggregation of generator limits
Reactive power limits from generators are aggregated onto buses before graph construction.
For each `(scenario, bus)`, the preprocessing sums:
- `min_q_mvar`
- `max_q_mvar`
across all generators connected to that bus, and merges these totals into the bus feature table.
This enriches bus nodes with bus-level reactive capability information.
### Target construction
Task labels are derived from subsets of the selected features.
- **Bus targets** are taken from the leading subset of bus features
- **Generator targets** are taken from the leading subset of generator features
- **Branch targets** are stored separately as edge-level flow quantities
The exact interpretation of inputs and outputs depends on the downstream task (e.g. PF, OPF, state estimation, reconstruction).
### Heterogeneous graph construction
Each scenario is converted into a `HeteroData` graph with:
- **bus nodes**
- **generator nodes**
- **bus-to-bus edges** for physical branches
- **generator-to-bus edges**
- **bus-to-generator edges**
This yields a heterogeneous graph representation that preserves both the electrical network structure and generator attachment structure.
### Storage format
Instead of storing one file per scenario, the processed dataset is written into a small number of large NumPy memory-mapped arrays (`memmap`).
This avoids metadata overhead on large cluster file systems and enables efficient random access.
The processed directory contains arrays such as:
- `bus_x.npy`, `bus_y.npy`
- `gen_x.npy`, `gen_y.npy`
- `edge_index.npy`, `edge_attr.npy`, `edge_y.npy`
- `gen_bus_ei.npy`, `bus_gen_ei.npy`
along with an `index.pt` file containing per-scenario offsets.
Using these offsets, a single scenario can be loaded without materializing the full dataset in memory.
### Runtime loading and normalization
When a sample is accessed:
1. the corresponding slices are read from the memmap arrays,
2. a PyTorch Geometric `HeteroData` object is reconstructed,
3. edge indices are converted into PyG format,
4. feature normalization is applied at access time.
Normalization is therefore **not baked into the stored arrays**, but applied dynamically during dataset loading. |