Datasets:
| attack_end_timestamp: null | |
| attack_start_timestamp: null | |
| attacking_duration_sec: 14.986093997955322 | |
| collection_duration_sec: 50.78523397445679 | |
| data_attack_info: | |
| attack_effect: | |
| description: After shifting from reverse to neutral and then to park, the vehicle | |
| cannot engage any gear. The dashboard/instrument displays '电驱动报错' (electric | |
| drive error) and multiple other error reports, indicating compromised gear selection | |
| and electric drive system malfunction. | |
| level: motion control compromised | |
| attack_type: | |
| config: | |
| dlc_option: dlcKeep | |
| id_option: aliveId | |
| kind: fuzzing | |
| attacked_domain: 1 | |
| data_collection_info: | |
| avg_speed: 20.0 | |
| description: start moving;attack start;vehicle exhibits shift failure from reverse | |
| to neutral and after shifting to park cannot engage gear, accompanied by multiple | |
| errors including electric drive error;attack end;stop moving | |
| end_place: Xishatun Bridge | |
| intelligent_driving: false | |
| road_type: RuralRoad | |
| start_place: Xishatun Bridge | |
| group_name: fuzzing_0015 | |