Refresh the dataset card
Browse files
README.md
CHANGED
|
@@ -164,10 +164,10 @@ spacing and gantry tilt are all common.
|
|
| 164 |
|
| 165 |
[highdicom](https://highdicom.readthedocs.io/) handles this, and returns a
|
| 166 |
`Volume` that keeps voxel spacing and the patient-space affine next to the
|
| 167 |
-
array. The examples below were tested with highdicom 0.
|
| 168 |
|
| 169 |
```bash
|
| 170 |
-
pip install "highdicom>=0.
|
| 171 |
```
|
| 172 |
|
| 173 |
Start in the catalog. `volume_geometry_index` flags every CT, MR and PET series
|
|
@@ -287,11 +287,11 @@ A segmentation often covers fewer slices than its image, is rotated relative to
|
|
| 287 |
the source image, or stores the slices in the opposite order; `match_geometry`
|
| 288 |
pads, flips and rotates it (as required) onto the image grid. It raises
|
| 289 |
`RuntimeError` when the two grids are offset by a fraction of a voxel, and
|
| 290 |
-
rounding in stored positions alone can cause that
|
| 291 |
-
|
| 292 |
-
|
| 293 |
you need: a large tolerance can hide a segmentation that is genuinely misaligned
|
| 294 |
-
with its image.
|
| 295 |
|
| 296 |
`combine_segments=True` returns a label map, in which each voxel holds the
|
| 297 |
number of the segment it belongs to, or 0. NLSTSeg segments each lesion
|
|
|
|
| 164 |
|
| 165 |
[highdicom](https://highdicom.readthedocs.io/) handles this, and returns a
|
| 166 |
`Volume` that keeps voxel spacing and the patient-space affine next to the
|
| 167 |
+
array. The examples below were tested with highdicom 0.29.0.
|
| 168 |
|
| 169 |
```bash
|
| 170 |
+
pip install "highdicom>=0.29.0" duckdb idc-index torch
|
| 171 |
```
|
| 172 |
|
| 173 |
Start in the catalog. `volume_geometry_index` flags every CT, MR and PET series
|
|
|
|
| 287 |
the source image, or stores the slices in the opposite order; `match_geometry`
|
| 288 |
pads, flips and rotates it (as required) onto the image grid. It raises
|
| 289 |
`RuntimeError` when the two grids are offset by a fraction of a voxel, and
|
| 290 |
+
rounding in stored positions alone can occasionally cause that. In such cases,
|
| 291 |
+
`match_geometry(ct, position_tol=tol)` can be used to loosen the tolerance to
|
| 292 |
+
accept them, where by default `tol=1e-2`. Loosen `position_tol` no further than
|
| 293 |
you need: a large tolerance can hide a segmentation that is genuinely misaligned
|
| 294 |
+
with its image and requires resampling.
|
| 295 |
|
| 296 |
`combine_segments=True` returns a label map, in which each voxel holds the
|
| 297 |
number of the segment it belongs to, or 0. NLSTSeg segments each lesion
|