study team,objective,Entity Facet:Entity(IFC Class),Property Facet:Property Set(PropertySet),Property Facet:PropertyName(PropertyName),Property Facet:Data Type(DataType),Property Facet:Value(PropertyValue)

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,Reference,IFCIDENTIFIER,Beam-A1

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,Status,IFCLABEL,New

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,IsExternal,IFCBOOLEAN,true

ARC,Beam(ARC),IfcBeam,BeamCommon,LoadBearing,IFCBOOLEAN,true

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,FireRating,IFCLABEL,EI60

ARC,Beam(ARC),IfcBeam,Pset_Warranty,WarrantyIdentifier,IFCIDENTIFIER,WR-BEAM-A1

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,ThermalTransmittance,IFCTHERMALTRANSMITTANCEMEASURE,1.2

ARC,Beam(ARC),IfcBeam,Tolerance,OverallTolerance,IFCPOSITIVELENGTHMEASURE,0.004

ARC,Beam(ARC),IfcBeam,Tolerance,VerticalTolerance,IFCPOSITIVELENGTHMEASURE,0.003

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,Slope,IFCPLANEANGLEMEASURE,0.0015

ARC,Beam(ARC),IfcBeam,Tolerance,PlanarFlatness,IFCPOSITIVELENGTHMEASURE,0.002

ARC,Beam(ARC),IfcBeam,Pset_ConcreteElementGeneral,StructuralClass,IFCLABEL,PrimaryBeam

ARC,Beam(ARC),IfcBeam,Pset_ConcreteElementGeneral,DimensionalAccuracyClass,IFCLABEL,Normal

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,Length,IFCLENGTHMEASURE,0.300

ARC,Beam(ARC),IfcBeam,Pset_PrecastConcreteElementGeneral,MinimumAllowableSupportLength,IFCPOSITIVELENGTHMEASURE,0.150

ARC,Beam(ARC),IfcBeam,Pset_ReinforcementBarPitchOfBeam,SpacingBarPitch,IFCPOSITIVELENGTHMEASURE,0.310

ARC,Beam(ARC),IfcBeam,Pset_ReinforcementBarPitchOfBeam,StirrupBarPitch,IFCPOSITIVELENGTHMEASURE,0.155

ARC,Beam(ARC),IfcBeam,MaintenanceStrategy,AssetCriticality,IFCLABEL,MEDIUM

ARC,Beam(ARC),IfcBeam,PrecastConcreteElementFabrication,TypeDesignation,IFCLABEL,I-shape

ARC,Beam(ARC),IfcBeam,Pset_Warranty,WarrantyStartDate,IFCDATE,2025-04-01

ARC,Beam(ARC),IfcBeam,Pset_PrecastConcreteElementGeneral,CamberAtMidspan,IFCRATIOMEASURE,0.005

ARC,Beam(ARC),IfcBeam,Pset_ConcreteElementGeneral,ExposureClass,IFCLABEL,Top

ARC,Beam(ARC),IfcBeam,MaintenanceStrategy,MonitoringType,IFCLABEL,VisualInspection

ARC,Beam(ARC),IfcBeam,Tolerance,OverallStraightness,IFCPOSITIVELENGTHMEASURE,0.00005

ARC,Beam(ARC),IfcBeam,Risk,RiskType,IFCLABEL,Chemical Effects

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,CrossSectionArea,IFCAREAMEASURE,0.075

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,GrossSurfaceArea,IFCAREAMEASURE,4.60

ARC,Beam(ARC),IfcBeam,BodyGeometryValidation,SurfaceGenusAfterFeatures,IFCCOUNTMEASURE,2

ARC,Beam(ARC),IfcBeam,Pset_ConcreteElementGeneral,ConstructionToleranceClass,IFCLABEL,Standard

ARC,Beam(ARC),IfcBeam,MaintenanceStrategy,AssetPriority,IFCLABEL,MEDIUM

ARC,Beam(ARC),IfcBeam,Pset_PrecastConcreteElementGeneral,ManufacturingToleranceClass,IFCLABEL,Standard

ARC,Beam(ARC),IfcBeam,ConstructionOccurence,AssetIdentifier,IFCLABEL,Chamfer5

ARC,Beam(ARC),IfcBeam,Pset_ManufacturerTypeInformation,Manufacturer,IFCLABEL,BeamCo

ARC,Beam(ARC),IfcBeam,ConstructionOccurence,ModelNumber,IFCLABEL,BM-2024-A

ARC,Beam(ARC),IfcBeam,Warranty,PointOfContact,IFCLABEL,BeamCo service desk

ARC,Beam(ARC),IfcBeam,ConstructionOccurence,TagNumber,IFCLABEL,ISO9001

ARC,Beam(ARC),IfcBeam,Pset_BeamCommon,Span,IFCPOSITIVELENGTHMEASURE,6.0

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,GrossVolume,IFCVOLUMEMEASURE,0.405

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,NetVolume,IFCVOLUMEMEASURE,0.390

ARC,Beam(ARC),IfcBeam,Qto_BeamBaseQuantities,OuterSurfaceArea,IFCAREAMEASURE,4.2

ARC,Beam(ARC),IfcBeam,Pset_Warranty,WarrantyContent,IFCTEXT,Coordinate beam depth with services

ARC,Beam(ARC),IfcBeam,PrecastConcreteElementGeneral,SupportDuringTransportDocReference,IFCLABEL,BOLT-END-ACCESS-01

ARC,Beam(ARC),IfcBeam,Pset_PrecastConcreteElementGeneral,SupportDuringTransportDescription,IFCTEXT,Temporary bracing required during erection