Usecase,Component,Target IFCEntity,IFCPset,IFCProperty,IFCDataType,Value
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,Reference,IFCIDENTIFIER,CurtainWall-B2
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,Status,IFCLABEL,New
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,IsExternal,IFCBOOLEAN,false
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,ThermalTransmittance,IFCTHERMALTRANSMITTANCEMEASURE,0.52
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,GlobalTradeItemNumber,IFCIDENTIFIER,09506000234561
ARC,CurtainWall,IfcCurtainWall,Qto_CurtainWallQuantities,Width,IFCLENGTHMEASURE,1.35
ARC,CurtainWall,IfcCurtainWall,Qto_CurtainWallQuantities,Height,IFCLENGTHMEASURE,3.20
ARC,CurtainWall,IfcCurtainWall,MaintenanceStrategy,MonitoringType,IFCLABEL,RoutineInspection
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,ArticleNumber,IFCIDENTIFIER,CW-MOD-300
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,Combustible,IFCBOOLEAN,true
ARC,CurtainWall,IfcCurtainWall,Qto_CurtainWallQuantities,GrossSideArea,IFCAREAMEASURE,1.60
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,FireRating,IFCLABEL,WL4
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,SurfaceSpreadOfFlame,IFCLABEL,Class2
ARC,CurtainWall,IfcCurtainWall,Pset_CurtainWallCommon,AcousticRating,IFCLABEL,Rw40
ARC,CurtainWall,IfcCurtainWall,ManufacturerTypeInformation,SafetyDocument,IFCLABEL,DOC-CW-SAFE-01
ARC,CurtainWall,IfcCurtainWall,ConstructionAdministration,ProcurementMethod,IFCLABEL,Specialty subcontract
ARC,CurtainWall,IfcCurtainWall,ConstructionAdministration,SpecificationSectionNumber,IFCLABEL,08 44 13
ARC,CurtainWall,IfcCurtainWall,Qto_CurtainWallQuantities,NetSideArea,IFCAREAMEASURE,1.35
ARC,CurtainWall,IfcCurtainWall,ConstructionAdministration,SubmittalIdentifer,IFCLABEL,SUB-CW-203
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,ModelReference,IFCLABEL,Unitized facade module
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,ModelLabel,IFCLABEL,Series 300 thermal break
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,ProductionYear,IFCLABEL,2025
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,AssemblyPlace,IFCLABEL,FACTORY
ARC,CurtainWall,IfcCurtainWall,ManufacturerTypeInformation,OperationalDocument,IFCLABEL,DOC-CW-OPS-01
ARC,CurtainWall,IfcCurtainWall,ManufacturerTypeInformation,PerformanceCertificate,IFCLABEL,CERT-CW-AAMA-01
ARC,CurtainWall,IfcCurtainWall,Pset_Warranty,WarrantyIdentifier,IFCIDENTIFIER,WR-CW-2025-01
ARC,CurtainWall,IfcCurtainWall,Pset_Warranty,WarrantyStartDate,IFCDATE,2025-09-01
ARC,CurtainWall,IfcCurtainWall,Pset_Warranty,IsExtendedWarranty,IFCBOOLEAN,true
ARC,CurtainWall,IfcCurtainWall,Warranty,WarrantyPeriod,IFCLABEL,P10Y
ARC,CurtainWall,IfcCurtainWall,Pset_Warranty,WarrantyContent,IFCTEXT,Module finish and gaskets covered under manufacturer warranty
ARC,CurtainWall,IfcCurtainWall,Warranty,PointOfContact,IFCLABEL,NeoFacade service team
ARC,CurtainWall,IfcCurtainWall,Pset_Warranty,Exclusions,IFCTEXT,Glass breakage from impact is excluded
ARC,CurtainWall,IfcCurtainWall,Tolerance,ToleranceDescription,IFCTEXT,Module alignment tolerance per approved shop drawings
ARC,CurtainWall,IfcCurtainWall,Tolerance,OverallTolerance,IFCPOSITIVELENGTHMEASURE,0.005
ARC,CurtainWall,IfcCurtainWall,Tolerance,HorizontalTolerance,IFCPOSITIVELENGTHMEASURE,0.004
ARC,CurtainWall,IfcCurtainWall,Tolerance,VerticalTolerance,IFCPOSITIVELENGTHMEASURE,0.004
ARC,CurtainWall,IfcCurtainWall,Tolerance,PlanarFlatness,IFCPOSITIVELENGTHMEASURE,0.003
ARC,CurtainWall,IfcCurtainWall,Tolerance,ElevationalFlatness,IFCPOSITIVELENGTHMEASURE,0.004
ARC,CurtainWall,IfcCurtainWall,Pset_Condition,AssessmentDescription,IFCTEXT,Frame finish visually confirmed
ARC,CurtainWall,IfcCurtainWall,Pset_Condition,AssessmentDate,IFCDATE,2025-10-12
ARC,CurtainWall,IfcCurtainWall,Pset_Condition,AssessmentCondition,IFCLABEL,Weather-tight
ARC,CurtainWall,IfcCurtainWall,Condition,AssessmentType,IFCLABEL,Facade inspection
ARC,CurtainWall,IfcCurtainWall,Condition,AssessmentMethod,IFCLABEL,DOC-CW-INSP-01
ARC,CurtainWall,IfcCurtainWall,Condition,LastAssessmentReport,IFCLABEL,RPT-CW-2025-10
ARC,CurtainWall,IfcCurtainWall,Pset_ManufacturerTypeInformation,Manufacturer,IFCLABEL,NeoFacade
ARC,CurtainWall,IfcCurtainWall,ConstructionOccurence,ModelNumber,IFCLABEL,CW-300
ARC,CurtainWall,IfcCurtainWall,Condition,NextAssessmentDate,IFCDATE,2026-10-12
ARC,CurtainWall,IfcCurtainWall,Condition,AssessmentFrequency,IFCTIMEMEASURE,8760
ARC,CurtainWall,IfcCurtainWall,MaintenanceStrategy,AssetCriticality,IFCLABEL,HIGH
ARC,CurtainWall,IfcCurtainWall,MaintenanceStrategy,AssetPriority,IFCLABEL,HIGH
ARC,CurtainWall,IfcCurtainWall,MaintenanceTriggerCondition,ConditionMaintenanceLevel,IFCLABEL,Moderate
ARC,CurtainWall,IfcCurtainWall,MaintenanceTriggerDuration,DurationMaintenanceLevel,IFCLABEL,P365D
ARC,CurtainWall,IfcCurtainWall,Qto_CurtainWallQuantities,Length,IFCLENGTHMEASURE,48.0
ARC,CurtainWall,IfcCurtainWall,Risk,RiskName,IFCLABEL,Seal failure
ARC,CurtainWall,IfcCurtainWall,Risk,MitigationPlanned,IFCLABEL,Inspect perimeter joints annually