File size: 8,466 Bytes
5ab75a9
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
classdef (SharedTestFixtures = { ...
        matlab.unittest.fixtures.PathFixture('..')}) ...
        EstimateObjectMassQuantiles_UnitTest < matlab.unittest.TestCase


    %% Series of Tests intended to test masses generated based on RCS data

    methods (Test)
        function test01(testCase) % NaK Sphere 1 (Object 26503)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCSdB           = -21.52;
            RCS             = 10^(RCSdB/10);
            Cd              = 2.1;
            CdVar           = (0.05*Cd)^2;
            B               = 0.059683;
            BVar            = 0.0143760217028217*B^2;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = [0.169667721610686,0.327524869650403,0.628582698232823,0.925835980116696,1.349637666110859,1.871334705533626];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end
        function test02(testCase) % NaK Sphere 2 (Object 26504)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCSdB           = -21.25;
            RCS             = 10^(RCSdB/10);
            Cd              = 2.1;
            CdVar           = (0.05*Cd)^2;
            B               = 0.056492;
            BVar            = [0.0264187433463441]*B^2;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = [0.199525229770818,0.376849027794647,0.730146968789858,1.102981350527719,1.648134602978453,2.217976283447416];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end
        function test03(testCase) % NaK Sphere 4 (Object 26506)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCSdB           = -23.40;
            RCS             = 10^(RCSdB/10);
            Cd              = 2.1;
            CdVar           = (0.05*Cd)^2;
            B               = [0.0621120000000000];
            BVar            = 0;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = [0.077745871971655   0.174359117903039   0.365685944797085   0.529234782174568   0.764855594384428   1.006353811235473];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end
        function test04(testCase) % 6U Cubesat (Object 41732)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCS             = [0.117000000000000];
            Cd              = [2.63600000000000];
            CdVar           = (0.05*Cd)^2;
            B               = [0.0225378343256024];
            BVar            = [0.0178510503892628]*B^2;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = 100*[0.137396278972516   0.221975862955034   0.401814232256918   0.577762172120399   0.832995791005345   1.041708688553857];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end
        function test05(testCase) % 1U Cubesat (Object 39087)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCS             = [0.0310000000000000];
            Cd              = [2.63600000000000];
            CdVar           = (0.05*Cd)^2;
            B               = [0.0724078366853101];
            BVar            = 0;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = [1.031123463206458   1.767524195130710   3.199531242338608   4.448322781112397   6.197836724391296   8.220433807065415];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end
        function test06(testCase) % GNB Satellite (Object 40908)
            Accuracy        = 0.05; % Relative 5% tolerance for well defined quantiles
            RCS             = [0.0950000000000000];
            Cd              = [2.63600000000000];
            CdVar           = (0.05*Cd)^2;
            B               = [0.0155905471428639];
            BVar            = [0.0206862273022415]*B^2;
            QuantileVector  = [.5 .75 .95 .99 0.999 0.9999];
            NumOfSamples    = 100000;

            expSolution     = 100*[0.161277045683952   0.261181468663888   0.473424212877117   0.673669816774682   0.996015412107316   1.275705056460007];


            % Calculate Mass Estimates
            [massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
            actSolution     = [QuantileArray(:).MassEstimate];

            % Set tolerances based on quantile with relaxed values near edges as shown in:
            % Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
            % Quantile Estimations from Finite Samples of Data"
            % https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
            Accuracy        = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;

            testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
        end