5ab75a9 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 | classdef (SharedTestFixtures = { ...
matlab.unittest.fixtures.PathFixture('..')}) ...
EstimateObjectMassQuantiles_UnitTest < matlab.unittest.TestCase
%% Series of Tests intended to test masses generated based on RCS data
methods (Test)
function test01(testCase) % NaK Sphere 1 (Object 26503)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCSdB = -21.52;
RCS = 10^(RCSdB/10);
Cd = 2.1;
CdVar = (0.05*Cd)^2;
B = 0.059683;
BVar = 0.0143760217028217*B^2;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = [0.169667721610686,0.327524869650403,0.628582698232823,0.925835980116696,1.349637666110859,1.871334705533626];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
end
function test02(testCase) % NaK Sphere 2 (Object 26504)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCSdB = -21.25;
RCS = 10^(RCSdB/10);
Cd = 2.1;
CdVar = (0.05*Cd)^2;
B = 0.056492;
BVar = [0.0264187433463441]*B^2;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = [0.199525229770818,0.376849027794647,0.730146968789858,1.102981350527719,1.648134602978453,2.217976283447416];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
end
function test03(testCase) % NaK Sphere 4 (Object 26506)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCSdB = -23.40;
RCS = 10^(RCSdB/10);
Cd = 2.1;
CdVar = (0.05*Cd)^2;
B = [0.0621120000000000];
BVar = 0;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = [0.077745871971655 0.174359117903039 0.365685944797085 0.529234782174568 0.764855594384428 1.006353811235473];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
end
function test04(testCase) % 6U Cubesat (Object 41732)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCS = [0.117000000000000];
Cd = [2.63600000000000];
CdVar = (0.05*Cd)^2;
B = [0.0225378343256024];
BVar = [0.0178510503892628]*B^2;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = 100*[0.137396278972516 0.221975862955034 0.401814232256918 0.577762172120399 0.832995791005345 1.041708688553857];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
end
function test05(testCase) % 1U Cubesat (Object 39087)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCS = [0.0310000000000000];
Cd = [2.63600000000000];
CdVar = (0.05*Cd)^2;
B = [0.0724078366853101];
BVar = 0;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = [1.031123463206458 1.767524195130710 3.199531242338608 4.448322781112397 6.197836724391296 8.220433807065415];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);
end
function test06(testCase) % GNB Satellite (Object 40908)
Accuracy = 0.05; % Relative 5% tolerance for well defined quantiles
RCS = [0.0950000000000000];
Cd = [2.63600000000000];
CdVar = (0.05*Cd)^2;
B = [0.0155905471428639];
BVar = [0.0206862273022415]*B^2;
QuantileVector = [.5 .75 .95 .99 0.999 0.9999];
NumOfSamples = 100000;
expSolution = 100*[0.161277045683952 0.261181468663888 0.473424212877117 0.673669816774682 0.996015412107316 1.275705056460007];
% Calculate Mass Estimates
[massVec,QuantileArray] = EstimateObjectMassQuantiles(RCS,B,BVar,Cd,CdVar,QuantileVector,NumOfSamples);
actSolution = [QuantileArray(:).MassEstimate];
% Set tolerances based on quantile with relaxed values near edges as shown in:
% Roy P., Laprise, R., and Gachon, P., "Sampling Errors of
% Quantile Estimations from Finite Samples of Data"
% https://arxiv.org/ftp/arxiv/papers/1610/1610.03458.pdf
Accuracy = Accuracy.*(QuantileVector./(1-QuantileVector)).^0.47;
testCase.verifyEqual(actSolution,expSolution,'RelTol',Accuracy);