function [Pc,out] = PcMultiStepWithSDMC(r1,v1,C1,r2,v2,C2,HBR,params)
% PcMultiStepWithSDMC - Calculate the collision probability for a
% conjunction using a multi-tiered algorithm,
% including the Simple Dynamics Monte Carlo (SDMC)
% calculation.
%
% Syntax: [Pc, out] = PcMultiStepWithSDMC(r1,v1,C1,r2,v2,C2,HBR);
% [Pc, out] = PcMultiStepWithSDMC(r1,v1,C1,r2,v2,C2,HBR,params);
%
% =========================================================================
%
% Copyright (c) 2023-2025 United States Government as represented by the
% Administrator of the National Aeronautics and Space Administration.
% All Rights Reserved.
%
% =========================================================================
%
% Description:
%
% This function builds on PcMultiStep by adding the option of executing
% Pc_SDMC after running PcMultiStep, in order to estimate the collision
% probability for a single conjunction using a 2-Body Monte Carlo
% algorithm. By default, the SDMC algorithm will only be run if there are
% usage violations encountered in all PcMultiStep algorithms or if the Pc
% returned by PcMultiStep is greater than or equal to the Pc defined in the
% PcToForceSDMCCalculation parameter. Alternatively, a user can force the
% SDMC Pc to be calculated uing the ForceSDMCCalculation parameter.
%
% Note: "BFMC" is a tool used internal to NASA CARA and will not be
% publicly released. References to BFMC within the code should be
% ignored by external users. Minimal documentation will be provided
% for any BFMC functionality which may appear within the code.
%
% =========================================================================
%
% Inputs:
%
% r1 - Primary object's ECI position vector (m) [3x1 or 1x3]
%
% v1 - Primary object's ECI velocity vector (m/s) [3x1 or 1x3]
%
% C1 - Primary object's ECI covariance matrix (m position units) [6x6]
%
% r2 - Secondary object's ECI position vector (m) [3x1 or 1x3]
%
% v2 - Secondary object's ECI velocity vector (m/s) [3x1] or [1x3]
%
% C2 - Secondary object's ECI covariance matrix (m position units) [6x6]
%
% HBR - Combined primary+secondary hard-body radii. [1x1, 1x2, or 2x1]
% If two elemens are passed in, it is assumed
% each element separately represents each
% object's individual HBR. In this case, the HBRs
% are added together to create a single unified
% combined HBR.
%
% params - (Optional) Other input parameters structure which expands on
% the structure defined by PcMultiStep.m. The following fields
% are specific to this function:
%
% ForceSDMCCalculation - Boolean which forces the SDMC calculation to
% be performed, regardless of usage violations
% encountered.
% Defaults to false.
%
% PreventSDMCCalculation - Boolean which prevents the SDMC calculation
% from running. An SDMC calculation cannot
% both be forced and prevented.
% Defaults to false.
%
% SDMCParams - The "params" structure passed to Pc_SDMC. See Pc_SDMC.m
% for a definition of allowed fields within this
% structure.
% Defaults to an empty structure.
%
% PcToForceSDMCCalculation - A threshold (between 0 and 1) which
% defines a Pc returned from PcMultiStep
% above which an SDMC Pc will be
% calculated, regardless of usage
% violations.
% Defaults to 1.
%
% ForceRecommendedTrials - Boolean which forces SDMC to use the
% recommended number of trials regardless of
% the maximum trial constraint. Note: This
% could lead to very long SDMC run times.
% Defaults to false.
%
% =========================================================================
%
% Outputs:
%
% Pc - Recommended Pc value to use for this conjunction
%
% out - Auxiliary output information structure which adds to the "out"
% structure provided by PcMultiStep.m. This function adds or
% modifies the following output fields:
%
% SDMCPc - Pc calculated from the SDMCPc method (Pc_SDMC.m)
%
% PcMethod - Updates PcMethod from PcMultiStep.m, description of
% method used to calculate the recommended Pc
%
% PcMethodNum - Updates PcMethodNum from PcMultiStep.m, adds the
% following method numbers:
% 4 = SDMC Pc
% 5 = BFMC Pc
%
% PcMethodNumAnalytical - Value of PcMethodNum that was returned by
% PcMultiStep.m.
%
% PcMethodMax - Updates PcMethodMax from PcMultiStep.m, adds the
% following method numbers:
% 4 = SDMC Pc
% 5 = BFMC Pc
%
% PcMethodMaxAnalytical - Value of PcMethodMax that was returned by
% PcMultiStep.m.
%
% SDMCInfo - Copy of the "out" structure returned by Pc_SDMC.m. The
% following fields are added by this function:
%
% PcCalculated - Boolean indicating that an SDMC Pc was calculated.
%
% Indicators - Structure containing values calculated for SDMC
% usage violation checks, fields include:
%
% Extended - Extended conjunction duration indicator (# of "hits"
% that are outside encounter start/stop time
% boundaries)
%
% Violations - Structure of booleans showing SDMC usage violations,
% fields include:
%
% Extended - True if extended indicator is greater than 0
%
% Offset - True if any Nc-3D offset violations exist.
%
% AnySDMCViolations - Boolean which indicates if any Exteded or Offset
% SDMC usage violations exist.
%
% SDMCParams - A copy of the "params" structure that was used when
% calling Pc_SDMC.m.
%
% =========================================================================
%
% Disclaimer:
%
% No Warranty: THE SUBJECT SOFTWARE IS PROVIDED "AS IS" WITHOUT ANY
% WARRANTY OF ANY KIND, EITHER EXPRESSED, IMPLIED, OR STATUTORY,
% INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY THAT THE SUBJECT SOFTWARE
% WILL CONFORM TO SPECIFICATIONS, ANY IMPLIED WARRANTIES OF
% MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR FREEDOM FROM
% INFRINGEMENT, ANY WARRANTY THAT THE SUBJECT SOFTWARE WILL BE ERROR
% FREE, OR ANY WARRANTY THAT DOCUMENTATION, IF PROVIDED, WILL CONFORM TO
% THE SUBJECT SOFTWARE. THIS AGREEMENT DOES NOT, IN ANY MANNER,
% CONSTITUTE AN ENDORSEMENT BY GOVERNMENT AGENCY OR ANY PRIOR RECIPIENT
% OF ANY RESULTS, RESULTING DESIGNS, HARDWARE, SOFTWARE PRODUCTS OR ANY
% OTHER APPLICATIONS RESULTING FROM USE OF THE SUBJECT SOFTWARE.
% FURTHER, GOVERNMENT AGENCY DISCLAIMS ALL WARRANTIES AND LIABILITIES
% REGARDING THIRD-PARTY SOFTWARE, IF PRESENT IN THE ORIGINAL SOFTWARE,
% AND DISTRIBUTES IT "AS IS."
%
% Waiver and Indemnity: RECIPIENT AGREES TO WAIVE ANY AND ALL CLAIMS
% AGAINST THE UNITED STATES GOVERNMENT, ITS CONTRACTORS AND
% SUBCONTRACTORS, AS WELL AS ANY PRIOR RECIPIENT. IF RECIPIENT'S USE OF
% THE SUBJECT SOFTWARE RESULTS IN ANY LIABILITIES, DEMANDS, DAMAGES,
% EXPENSES OR LOSSES ARISING FROM SUCH USE, INCLUDING ANY DAMAGES FROM
% PRODUCTS BASED ON, OR RESULTING FROM, RECIPIENT'S USE OF THE SUBJECT
% SOFTWARE, RECIPIENT SHALL INDEMNIFY AND HOLD HARMLESS THE UNITED
% STATES GOVERNMENT, ITS CONTRACTORS AND SUBCONTRACTORS, AS WELL AS ANY
% PRIOR RECIPIENT, TO THE EXTENT PERMITTED BY LAW. RECIPIENT'S SOLE
% REMEDY FOR ANY SUCH MATTER SHALL BE THE IMMEDIATE, UNILATERAL
% TERMINATION OF THIS AGREEMENT.
%
% =========================================================================
%
% Initial version: Aug 2023; Latest update: Aug 2025
%
% ----------------- BEGIN CODE -----------------
% Add required library paths
persistent pathsAdded
if isempty(pathsAdded)
[p,~,~] = fileparts(mfilename('fullpath'));
s = what(fullfile(p, 'Utils')); addpath(s.path);
s = what(fullfile(p, '../Utils/PosVelTransformations')); addpath(s.path);
pathsAdded = true;
end
% Default inputs
Nargin = nargin;
if Nargin < 8; params = []; end
% Flag to force Pc calculations using the SDMC method
params = set_default_param(params,'ForceSDMCCalculation', false);
params = set_default_param(params,'PreventSDMCCalculation',false);
% Ensure 2D-Nc and 3D-Nc are calculated, if SDMC is forced
if params.ForceSDMCCalculation
params.ForceNc2DCalculation = true; params.PreventNc2DCalculation = false;
params.ForceNc3DCalculation = true; params.PreventNc3DCalculation = false;
end
%% Call PcMultiStep to calculate the Pc2D, Nc2D and Nc3D methods
% Call PcMultiStep
[Pc,out] = PcMultiStep(r1,v1,C1,r2,v2,C2,HBR,params);
% Return if any data quality errors were detected
if out.AnyDataQualityErrors
return;
end
%% Check the SDMC run parameters
% Default parameters for Pc_SDMC function
params = out.MultiStepParams;
params = set_default_param(params,'SDMCParams',[]);
% Pc level to force using the SDMC method
params = set_default_param(params,'PcToForceSDMCCalculation',1);
% Flags to prevent SDMC method from running.
% Note: 2D-Nc or 3D-Nc cannot be prevented from running if SDMC is
% forced to run. In addition, a user cannot both prevent and
% force a Pc calculation.
% SDMC must also be prevented if 3D-Nc is also prevented
params = set_default_param(params,'PreventSDMCCalculation',params.PreventNc3DCalculation);
% Forces SDMC to use the recommended number of trials instead of
% limiting to max trials
overrideForceRecTrials = false;
if isfield(params,'ForceRecommendedTrials')
overrideForceRecTrials = true;
end
params = set_default_param(params,'ForceRecommendedTrials',false);
% Check the prevent/force parameters
if params.PreventSDMCCalculation && params.ForceSDMCCalculation
error('SDMC cannot be both prevented and forced to run.');
end
% Check if SDMC calculation is required
if params.PreventSDMCCalculation
NeedSDMCCalculation = false;
elseif params.ForceSDMCCalculation || isnan(Pc)
% Calculate SDMC if forced or if the output Pc value remains undefined
NeedSDMCCalculation = true;
elseif out.NeedNc3DCalculation && out.AnyNc3DViolations
% Calculate SDMC if there were any 3D-Nc method usage violations
NeedSDMCCalculation = true;
elseif Pc >= params.PcToForceSDMCCalculation(1)
% Calculate SDMC if semi-analytical Pc estimate is sufficiently large
NeedSDMCCalculation = true;
else
NeedSDMCCalculation = false;
end
%% Perform the SDMC calculation, if required
if NeedSDMCCalculation
% Initialize parameters
SDMCParams = params.SDMCParams;
% Get the Pc value from the previous Pc calculations
SDMCParams.InputPc = Pc;
% Copy the ForceRecommendedTrials, if it was defined
if overrideForceRecTrials
SDMCParams.ForceRecommendedTrials = params.ForceRecommendedTrials;
end
% Make sure the generate_ca_dist_plot parameter gets transferred
if isfield(params,'generate_ca_dist_plot')
SDMCParams.generate_ca_dist_plot = params.generate_ca_dist_plot;
end
% Set the cross cov. correction parameters for the Nc3D calculation
if params.apply_covXcorr_corrections
[SDMCParams.apply_covXcorr_corrections, ...
SDMCParams.covXcorr.sigp,SDMCParams.covXcorr.Gvecp, ...
SDMCParams.covXcorr.sigs,SDMCParams.covXcorr.Gvecs] = ...
get_covXcorr_parameters(params);
else
SDMCParams.apply_covXcorr_corrections = false;
end
% Calculate the SDMC time span and midpoint
minPropTime = 3 * 60; % 3 minutes
if ~isfield(SDMCParams,'span_days') || isempty(SDMCParams.span_days)
if ~isnan(out.Nc3D) && out.Nc3DInfo.Converged
% Time limits per Pc3D_Hall calculation
Ta = out.Nc3DInfo.TaConj;
Tb = out.Nc3DInfo.TbConj;
TA = out.Nc3DInfo.Tmin_limit;
TB = out.Nc3DInfo.Tmax_limit;
% Expand the limits based on 3DNc violations
if out.AnyNc3DViolations
expand = inf;
else
expand = 3;
end
% Calculate the midpoint and time bounds, this generally will
% be a short time region about the midpoint (which isn't always
% near TCA). This calculation significantly saves on wasted
% propagation performed by SDMC.
tmid = (Tb+Ta)/2;
dt = max(expand*max(Tb-Ta,1e-300),minPropTime)/2;
ta = max(TA,tmid-dt);
tb = min(TB,tmid+dt);
SDMCParams.tmid = (tb+ta)/2;
SDMCParams.span_days = (tb-ta)/2 / 86400;
elseif ~isnan(out.Nc2D) && out.Nc2DInfo.Converged
% Time limits per Pc2D_Hall computation
Ta = out.Nc2DInfo.Ta;
Tb = out.Nc2DInfo.Tb;
% Expand the limits based on 2DNc violations
if out.AnyNc2DViolations
expand = inf;
else
expand = 3;
end
% Calculate the midpoint and time bounds, this generally will
% be a short time region about the midpoint (which isn't always
% near TCA). This calculation significantly saves on wasted
% propagation performed by SDMC.
SDMCParams.tmid = (Tb+Ta)/2;
dt = max(expand*(Tb-Ta),minPropTime)/2;
ta = SDMCParams.tmid-dt;
tb = SDMCParams.tmid+dt;
SDMCParams.span_days = (tb-ta)/2 / 86400;
end
else
SDMCParams.tmid = 0;
end
% Set the retrograde orbit reorientation mode
SDMCParams = set_default_param(SDMCParams, ...
'RetrogradeReorientation',params.RetrogradeReorientation);
% Save SDMC parameters
out.SDMCParams = SDMCParams;
% Don't try to call SDMC if Nc3D didn't converge and an invalid
% covariance has been detected
if (~out.Nc3DInfo.Converged && out.DataQualityError.invalidCov6x6)
out.SDMCPc = nan;
else
% Calculate the SDMC value
try
% Update max attempted Pc calculation method
% (1 = 2D-Pc, 2 = 2D-Nc, 3 = 3D-Nc, 4 = SDMC, 5 = BFMC)
out.PcMethodMaxAnalytical = out.PcMethodMax;
out.PcMethodMax = 4;
[out.SDMCPc, out.SDMCInfo] = ...
Pc_SDMC(r1,v1,C1,r2,v2,C2,HBR,SDMCParams);
catch ME
if strcmp(ME.identifier,'SDMC:invalid_6x6_cov')
out.SDMCPc = nan;
else
rethrow(ME);
end
end
end
% Process SDMC method usage violations
if isnan(out.SDMCPc)
% Convergence violation
out.SDMCInfo.PcCalculated = false;
out.AnySDMCViolations = true;
else
out.SDMCInfo.PcCalculated = true;
% Get the encounter segment
ta = out.SDMCInfo.ta;
tb = out.SDMCInfo.tb;
% Get the time points that are within 5% of the encounter
% start/stop times
pct5 = (tb - ta) * 0.05;
t_min = ta + pct5;
t_max = tb - pct5;
% Check to see if any hits occur outside of the min/max limits
trialData = out.SDMCInfo.trialData;
if ~isempty(trialData)
numHits = sum(trialData.hitIndicator == 1);
if numHits > 0
trialHits = trialData(trialData.hitIndicator == 1,:);
numExtendedHits = sum(trialHits.hitTime < t_min) + ...
sum(trialHits.hitTime > t_max);
else
numExtendedHits = 0;
end
else
numExtendedHits = 0;
end
% Extended conjunction duration usage violation indicator
out.SDMCInfo.Indicators.Extended = numExtendedHits;
% Extended conjunction violation occurs if any extended hits are
% encountered
out.SDMCInfo.Violations.Extended = out.SDMCInfo.Indicators.Extended > 0;
% Offset violation occurs if Nc3D had an offset violation
out.SDMCInfo.Violations.Offset = ~isfield(out.Nc3DInfo, 'Violations') || ...
out.Nc3DInfo.Violations.Offset;
% Check if any violations occured
out.AnySDMCViolations = out.SDMCInfo.Violations.Extended || ...
out.SDMCInfo.Violations.Offset;
% Check for a BFMC run to substitute for the SDMC run
out.SDMCInfo.BFMCsubstitution = false;
if isfield(params,'BFMCpath') && ~isempty(params.BFMCpath)
% Update the max Pc estimation method attempted so far
out.PcMethodMax = 5; % Indicates BFMC has been attempted
% Process BFMC VCM mode data
BFMClisfile = fullfile(params.BFMCpath,'bfmc_vcm.lis');
BFMCoutfile = fullfile(params.BFMCpath,'bfmc_vcm.out');
if ~exist(BFMClisfile,'file')
warning('bfmc_vcm.lis not found in specified path; not substituting BFMC data');
elseif ~exist(BFMCoutfile,'file')
warning('bfmc_vcm.out not found in specified path; not substituting BFMC data');
else
% Load BFMC conjunction data from .lis vile
BFMClisfile = fullfile(params.BFMCpath,'bfmc_vcm.lis');
[lisdata] = BFMC_lis_reader(BFMClisfile);
%
% % Test transformation from the BFMC ref. frame to
% the SDMC ref. frame: TEME2J2K
%
% % TCA epoch
% TCAUTC = datestr(lisdata.TCA,'yyyy-mm-dd HH:MM:SS.FFF');
%
% r1BFMC = [lisdata.PriX lisdata.PriY lisdata.PriZ ] * 1e3;
% v1BFMC = [lisdata.PriXdot lisdata.PriYdot lisdata.PriZdot] * 1e3;
%
% [r1TRAN,v1TRAN] = PosVelConvert(r1BFMC,v1BFMC, ...
% TCAUTC,'TEME2J2K','4terms'); % 4terms found to be better than 106terms !!!!
% [norm(r1-r1TRAN) norm(v1-v1TRAN)]
%
% Load BFMC trial data from .out file
disp('--- LOADING BFMC SUBSTITUTION DATA...')
SDMCInfo = out.SDMCInfo;
BFMCdata = array2table(load(BFMCoutfile,"-ascii"));
BFMCdata.Properties.VariableNames = out.SDMCInfo.trialData.Properties.VariableNames;
% Trim BFMC data to a round number of trials
numTrials = numel(BFMCdata.hitIndicator);
if numTrials < 1e4
warning('--- Fewer than 1e4 BFMC trials; not substituting BFMC data');
else
strTrials = smart_exp_format(numTrials,4);
rndTrials = str2double(strTrials);
if rndTrials < numTrials
disp(['--- ROUNDING BFMC TRIALS FROM ' num2str(numTrials) ' to ' strTrials])
BFMCdata = BFMCdata(1:rndTrials,:);
end
% Substitute BFMC data for SDMC data
disp('--- PROCESSING BFMC SUBSTITUTION DATA')
out.SDMCInfo.BFMCsubstitution = true;
out.SDMCInfo.numTrials = numel(BFMCdata.hitIndicator);
out.SDMCInfo.numHits = sum(BFMCdata.hitIndicator);
ndx = BFMCdata.hitRadius <= 1.01*2*sqrt(2)*HBR;
out.SDMCInfo.trialData = TransformBFMCdata(BFMCdata(ndx,:),lisdata.TCA);
out.SDMCInfo.overallPicTrialData = TransformBFMCdata(BFMCdata(1:1e4,:),lisdata.TCA);
[~,Pvalue] = binomial_prop_test( ...
out.SDMCInfo.numHits/out.SDMCInfo.numTrials,out.SDMCInfo.numTrials, ...
SDMCInfo.numHits/ SDMCInfo.numTrials, SDMCInfo.numTrials);
if Pvalue < 1e-3
warning(['Possible BFMC vs SDMC Pc difference: Pvalue = ' ...
smart_exp_format(Pvalue,3)]);
end
[out.SDMCInfo.Pc,out.SDMCInfo.PcUnc] = binofit( ...
out.SDMCInfo.numHits,out.SDMCInfo.numTrials);
out.SDMCPc = out.SDMCInfo.Pc;
out.SDMCInfo.Violations.Extended = 0;
out.SDMCInfo.Violations.Offset = 0;
end
end
end
end
% Update the reported Pc value
if out.SDMCInfo.PcCalculated
Pc = out.SDMCPc;
if out.SDMCInfo.BFMCsubstitution
out.PcMethod = 'BFMC';
out.PcMethodNumAnalytical = out.PcMethodNum;
out.PcMethodNum = 5;
else
out.PcMethod = 'SDMC';
out.PcMethodNumAnalytical = out.PcMethodNum;
out.PcMethodNum = 4;
end
end
end
end
%% ========================================================================
function data = TransformBFMCdata(data,TCADN)
% Transform BFMC state data into same ref. frame as SDMC state data
% Specifically: TEME2J2K with 4terms (found to be better than 106terms)
N = size(data,1);
disp(['---- TRANSFORMING STATES FOR ' num2str(N) ' TRIALS']);
% Extract states for parfor processing
priPosX_km = data.priPosX_km; priVelX_kmps = data.priVelX_kmps;
priPosY_km = data.priPosY_km; priVelY_kmps = data.priVelY_kmps;
priPosZ_km = data.priPosZ_km; priVelZ_kmps = data.priVelZ_kmps;
secPosX_km = data.secPosX_km; secVelX_kmps = data.secVelX_kmps;
secPosY_km = data.secPosY_km; secVelY_kmps = data.secVelY_kmps;
secPosZ_km = data.secPosZ_km; secVelZ_kmps = data.secVelZ_kmps;
% Hit times relative to TCA in days
hitTimeDays = data.hitTime/86400;
% Transform the states (TEME2J2K)
parfor n=1:N
% Epoch for this trial
EpochUTC = datestr(TCADN+hitTimeDays(n),'yyyy-mm-dd HH:MM:SS.FFF');
% Primary TCA states
[r,v] = PosVelConvert( ...
[priPosX_km(n) priPosY_km(n) priPosZ_km(n) ], ...
[priVelX_kmps(n) priVelY_kmps(n) priVelZ_kmps(n)], ...
EpochUTC,'TEME2J2K','4terms');
priPosX_km(n) = r(1);
priPosY_km(n) = r(2);
priPosZ_km(n) = r(3);
priVelX_kmps(n) = v(1);
priVelY_kmps(n) = v(2);
priVelZ_kmps(n) = v(3);
% Secondary TCA states
[r,v] = PosVelConvert( ...
[secPosX_km(n) secPosY_km(n) secPosZ_km(n) ], ...
[secVelX_kmps(n) secVelY_kmps(n) secVelZ_kmps(n)], ...
EpochUTC,'TEME2J2K','4terms');
secPosX_km(n) = r(1);
secPosY_km(n) = r(2);
secPosZ_km(n) = r(3);
secVelX_kmps(n) = v(1);
secVelY_kmps(n) = v(2);
secVelZ_kmps(n) = v(3);
end
% Store transformed states
data.priPosX_km = priPosX_km; data.priVelX_kmps = priVelX_kmps;
data.priPosY_km = priPosY_km; data.priVelY_kmps = priVelY_kmps;
data.priPosZ_km = priPosZ_km; data.priVelZ_kmps = priVelZ_kmps;
data.secPosX_km = secPosX_km; data.secVelX_kmps = secVelX_kmps;
data.secPosY_km = secPosY_km; data.secVelY_kmps = secVelY_kmps;
data.secPosZ_km = secPosZ_km; data.secVelZ_kmps = secVelZ_kmps;
end
% ----------------- END OF CODE ------------------
%
% Please record any changes to the software in the change history
% shown below:
%
% ----------------- CHANGE HISTORY ------------------
% Developer | Date | Description
% ---------------------------------------------------
% D. Hall | 2023-AUG-21 | Initial Development.
% L. Baars | 2023-AUG-24 | Fixed invalidCov6x6 field reference
% L. Baars | 2024-JAN-11 | Standardized "out" structure
% D. Hall | 2024-SEP-16 | Added support for BFMC data processing
% D. Hall | 2024-DEC-11 | Added PcMethod*Analytical outputs and
% adjusted PcMethod* outputs.
% L. Baars | 2025-AUG-22 | Updated code for public release.
% =========================================================================
%
% Copyright (c) 2023-2025 United States Government as represented by the
% Administrator of the National Aeronautics and Space Administration.
% All Rights Reserved.
%
% =========================================================================