# Timing information in molecular photoionization ## Background Photoelectron wave packets emitted from the two regions of an aligned diatomic ion can interfere. When a short, high-energy pulse propagates across the molecule, relative emission timing may be encoded in the final molecule-frame signal. The same angular structure can also be reshaped by the state-dependent photoionization response, so a numerical shift is not by itself a timing measurement. ## Research problem Using the physical model below, determine what quantitative information about the relative birth time of the two emitted wave packets, if any, can be reliably inferred from the final photoelectron signal. Apply the investigation to the lowest symmetric and first antisymmetric initial states and determine whether the evidence supports an initial-state dependence. How the inference is constructed and substantiated is for you to decide. Establish its physical meaning and identifiability from the computed evidence rather than assuming in advance that a particular angular feature is a valid clock. ## Physical inputs Use atomic units and the two-dimensional soft-core $\mathrm H_2^+$ model below. Work in coordinates $(z,x)$ with nuclei at $z=\pm R/2$, the molecular and pulse-propagation axes along $\hat{\mathbf z}$, and pulse polarization along $\hat{\mathbf x}$. The field-free potential is $$ V(z,x)=-\frac{1}{\sqrt{(z-R/2)^2+x^2+a}} -\frac{1}{\sqrt{(z+R/2)^2+x^2+a}}. $$ Use $R=2$ and $a=4.33$. The two initial states are the lowest symmetric and first antisymmetric eigenstates of this same field-free Hamiltonian. Retain propagation of the pulse across the molecule. Its finite-support vector potential is $$ \begin{aligned} \mathbf A(z,t)={}&A_0 \sin^2\!\left[\frac{\omega_e}{c}(z+a_0)-\omega_e t\right] \sin\!\left[\frac{\omega}{c}(z-ct)\right]\hat{\mathbf x}\\ &\times\left[ \theta_H\!\left(z-ct+\frac{\pi c}{\omega_e}+a_0\right) -\theta_H(z-ct+a_0) \right], \end{aligned} $$ where $\omega_e=\omega/(2N_{\mathrm{cyc}})$. Use | Quantity | Value | |---|---:| | Peak intensity | $1.0\times10^{14}\ \mathrm{W\,cm^{-2}}$ | | Central wavelength | $5$ nm | | Pulse duration | $N_{\mathrm{cyc}}=30$ cycles | | Initial pulse displacement | $a_0=10$ a.u. | Determine $\omega$ and $A_0$ using conventions consistent with a standard velocity-gauge nondipole TDSE. State the Fourier, momentum-axis, angular and delay-sign conventions used. ## Method boundary A standard velocity-gauge nondipole TDSE treatment is required. All task-specific analytical, numerical and evidential constructions are yours. Any comparison between the two initial states must use the same operational definition or demonstrate that the definitions are equivalent. You are responsible for establishing that the computed evidence is sufficiently reliable and physically discriminating for the conclusion made. No numerical implementation, post-processing recipe, display convention or validation procedure is prescribed. Absolute photoelectron yield is not a grading target. ## Submission Submit one self-contained scientific report and an offline reproduction package containing the derivation, executable code, reconstructible final photoelectron data for both initial states, the data underlying any quantitative timing claim, a provenance note listing every offline source or software document actually consulted and the method basis for items supplied from general knowledge, and concise run and environment information. The choice and number of figures are yours. No fixed file tree, filename scheme, complete exploratory history or examiner-selected diagnostic is required. The active examination resources and limits are defined in the companion `resource_limits.json`. All retained production calculations must run within that fixed allocation and active wall time. More expensive modelling does not receive additional credit. ## Reference and integrity policy This examination is conducted without network access or live literature retrieval. You may rely on your existing general scientific knowledge and, if any are explicitly supplied with the examination, on those offline materials or software documentation. Record every such source actually consulted. For formulas, methods, constants, or conventions used from general knowledge rather than a consulted source, state enough of the method basis, definition, value, units, and convention to make the calculation auditable; do not invent a citation. You are not required to identify or prove a publication date or to retrieve literature during the examination. The hidden target article and its identifying metadata, figures or captions, supplementary material, author code or data, target-specific reproduction code, solution or scoring material, online solutions, and worked reproductions of this case must not be used. All submitted scientific figures and numerical data must be generated by your own implementation of the stated problem. See [submission requirements](../../submission_requirements.md) for the common submission entry points.