--- title: add_sroute_connect(2) date: 24/09/08 --- # NAME add_sroute_connect - add sroute connect # SYNOPSIS add_sroute_connect -layers list_of_2_layers -cut_pitch pitch_value [-net net] [-outerNet outerNet] [-fixed_vias list_of_vias] [-max_rows rows] [-max_columns columns] [-metalwidths metalwidths] [-metalspaces metalspaces] [-ongrid ongrid_layers] [-insts inst] # DESCRIPTION The `add_sroute_connect` command is employed for connecting pins located outside of a specific power domain to the power ring, especially in cases where multiple power domains are present. During `sroute`, multi-cut vias will be added for new connections. The use of fixed vias from the technology file should be specified for the connection using the `add_sroute_connect` command. The use of max_rows and max_columns defines the row and column limit for the via stack. Example: ``` add_sroute_connect -net "VIN" -outerNet "VDD" -layers {met1 met4} -cut_pitch {200 200} -fixed_vias {M3M4_PR_M} -metalwidths {1000 1000} -metalspaces {800} -ongrid {met3 met4} -insts "temp_analog_1.a_header_0" ``` # OPTIONS `-net`: The inner net where the power ring exists. `-outerNet`: The outer net where instances/pins that need to get connected exist. `-layers`: The metal layers for vertical stripes within inner power ring. `-cut_pitch`: Distance between via cuts when the two layers are parallel, e.g., overlapping stdcell rails. (Default:200 200) `-fixed_vias`: List of fixed vias to be used to form the via stack. `-max_rows`: Maximum number of rows when adding arrays of vias. (Default:10) `-max_columns`: Maximum number of columns when adding arrays of vias. (Default:10) `-metalwidths`: Width for each metal layer. `-metalspaces`: Spacing of each metal layer. `-ongrid`: List of intermediate layers in a via stack to snap onto a routing grid. `-insts`: List of all the instances that contain the pin that needs to get connected with power ring. (Default:nothing) # ARGUMENTS This command has no arguments. # EXAMPLES # SEE ALSO