Update README.md
Browse files
README.md
CHANGED
|
@@ -1,56 +1,55 @@
|
|
| 1 |
Main protocol
|
| 2 |
|
| 3 |
Performer: Hamza \
|
| 4 |
-
Purpose / Hypothesis: To see pump height effect on signal.
|
| 5 |
|
| 6 |
Needle size: 22G
|
| 7 |
Needle tip: Chiba
|
| 8 |
|
| 9 |
-
Used Sensor : M.4.
|
| 10 |
-
Punctured Material: Foam
|
| 11 |
-
Phantom setup: Foam wrapped around tube.
|
| 12 |
|
| 13 |
|
| 14 |
|
| 15 |
-

|
| 28 |
|
| 29 |
-
|
| 30 |
|
|
|
|
| 31 |
|
| 32 |
|
| 33 |
-

|
| 34 |
|
| 35 |
-
1st Shelf Level
|
| 36 |
|
|
|
|
| 37 |
|
|
|
|
| 38 |
|
| 39 |
-

|
| 40 |
|
| 41 |
-
2nd Shelf Level
|
| 42 |
|
| 43 |
|
| 44 |
-
|
| 45 |
-
|
|
|
|
| 46 |
|
| 47 |
Filename meaning: \
|
| 48 |
-
|
|
|
|
|
|
|
| 49 |
|
| 50 |
-
position-depth of the needle shaft inside foam-level of pump-phantom-needle gauge-needle type-sensor-type_timestamp
|
| 51 |
|
|
|
|
| 52 |
|
| 53 |
-
Sensor places on channel 0. On channel 1 external microphone for sync sound detecting.
|
| 54 |
|
| 55 |
Needle tracking protocol
|
| 56 |
|
|
|
|
| 1 |
Main protocol
|
| 2 |
|
| 3 |
Performer: Hamza \
|
| 4 |
+
Purpose / Hypothesis: To see pump height effect on signal with stationary needles.
|
| 5 |
|
| 6 |
Needle size: 22G
|
| 7 |
Needle tip: Chiba
|
| 8 |
|
| 9 |
+
Used Sensor : M.4.4.0.22G and M.4.4.1.22G \
|
| 10 |
+
Punctured Material: Foam \
|
| 11 |
+
Phantom setup: Foam wrapped around tube. Dry foam used.
|
| 12 |
|
| 13 |
|
| 14 |
|
| 15 |
+

|
| 16 |
|
| 17 |
Extended:
|
| 18 |
|
| 19 |
+
Pump was running at 22 rpm. \
|
| 20 |
+
Pattern box used for stable tube and known pattern and distance from tube. \
|
| 21 |
+
2 differnt pump height used one was 1.5m and other one was same level as pattern box.
|
|
|
|
| 22 |
|
| 23 |
|
| 24 |
|
| 25 |
|
|
|
|
| 26 |
|
| 27 |
+

|
| 28 |
|
| 29 |
+
1.5M high
|
| 30 |
|
| 31 |
|
|
|
|
| 32 |
|
|
|
|
| 33 |
|
| 34 |
+

|
| 35 |
|
| 36 |
+
Same level
|
| 37 |
|
|
|
|
| 38 |
|
|
|
|
| 39 |
|
| 40 |
|
| 41 |
+
We used 2 different point on pattern. 5G cell and abovetube.
|
| 42 |
+
With 5G cell we had 3 different amount of needle shaft inside foam. 1cm , 2cm and 3cm mean how many cm of needle shaft was inside of foam during recording.
|
| 43 |
+
For abovetube point we used 2 different size which were 1 cm and 2 cm.
|
| 44 |
|
| 45 |
Filename meaning: \
|
| 46 |
+
1.5m_elevated_1st__M.4.4.0_2nd_M.4.4.1_dry_foam_22g_chiba_2025-10-21_18.04.09
|
| 47 |
+
|
| 48 |
+
level of pump-sensor-type-phantom-needle gauge-needle type_timestamp
|
| 49 |
|
|
|
|
| 50 |
|
| 51 |
+
M.4.4.0 Sensor placed on channel 0. On channel 1 M.4.4.1 microphone.
|
| 52 |
|
|
|
|
| 53 |
|
| 54 |
Needle tracking protocol
|
| 55 |
|