text
stringlengths
16
6.86k
[i. 7] ETSI GS NFV-IFA 008: "Network Functions Virtualisation (NFV) Release 5; Management and Orchestration; Ve-Vnfm reference point - Interface and Information Model Specification". [i. 8] ETSI GS NFV-IFA 013: "Network Functions Virtualisation (NFV) Release 5; Management and Orchestration; Os-Ma-nfvo reference poi...
1] and the following apply: ECC Error Correction Code MSCS Multi-Site Connectivity Service PCI Peripheral Component Interconnect PCIE PCI Express RAID Redundant Array of Independent Disks SCSI Small Computer System Interface SMART Self-Monitoring Analysis and Reporting Technology TMN Telecommunications ...
4 Overview 4. 1 Introduction Fault management is one of the five functional areas of the Telecommunications Management Network (TMN) model. Recommendation ITU-T M. 3400 [i. 2] defines fault management as the set of functions which enables the detection, isolation and correction of abnormal operation of the telecom...
The specification of alarms is contained in so called "information elements" in the stage 2 level specifications (see related references in clause 4. 2) or "data types" in the stage 3 level specifications of ETSI NFV. However, a subset of the attributes of the Alarm information element are either unspecified in terms...
4]: specifies the Or-Vi reference point requirements and interfaces including the Virtualised Resource Fault Management interface, which includes the operations for subscribing to, and raising alarm notifications related to virtualised resources. Clause 8. 6. 4 of ETSI GS NFV-IFA 005 [i. 4] specifies the Alarm infor...
• ETSI GS NFV-IFA 006 [i. 5]: idem as ETSI GS NFV-IFA 005 [i. 4] but concerning to the Vi-Vnfm reference point. • ETSI GS NFV-IFA 007 [i. 6]: specifies the Or-Vnfm reference point requirements and interfaces including the VNF Fault Management interface, which includes the operations for subscribing to, and raising ...
4. 2 of ETSI GS NFV-IFA 032 [i. 10] specifies the Alarm information element for MSCS instances. The present document specifies part of the content of the alarm related to the faults associated to MSCS instances. • ETSI GS NFV-IFA 040 [i. 12]: specifies the service interface requirements and object model for the man...
2, the Alarm information element contains the attribute "managedObjectId", which identifies the managed object associated to the Alarm. For each of the fault monitored object types, the corresponding managed object instance identifiers are identified with a reference to the respective referenced ETSI NFV specificati...
5. 2 Object type definitions 5. 2. 1 Virtual compute The fault monitored object type "VirtualCompute" is used to collect and report alarms for one or more instances of virtualised compute resource, i. e. a Virtual Machine (VM). The "managedObjectId", when used in an Alarm, corresponds to "computeId" (see clause 8....
4. 7. 2. 2 of ETSI GS NFV-IFA 005 [i. 4]) of the monitored virtualised storage resource. 5. 2. 5 Virtual NIC The fault monitored object type "VirtualNetworkInterface" is used to collect and report alarms for one or more instances of virtualised network interface resource. The "managedObjectId", when used in an Alar...
5. 2. 7 VNF The fault monitored object type "Vnf" is used to collect and report alarms for one or more instances of a VNF. The "managedObjectId", when used in an Alarm, corresponds to "vnfInstanceId" (see clause 9. 4. 2. 2 of ETSI GS NFV-IFA 008 [i. 7] or clause 8. 5. 2. 2 of ETSI GS NFV-IFA 007 [i. 6]) of the monit...
2 of ETSI GS NFV-IFA 007 [i. 6]) of the monitored internal VL instance of a VNF. 5. 2. 10 VNF internal CP The fault monitored object type "VnfIntCp" is used to collect and report alarms for one or more instances of VNF internal CP. The report of alarm information of VNF internal CP is provided via an Alarm associat...
The "managedObjectId", when used in an Alarm, corresponds to "nsInstanceId" (see clause 8. 3. 3. 2. 2 of ETSI GS NFV-IFA 013 [i. 8]) of the monitored NS instance. 5. 2. 13 NS virtual link The fault monitored object type "NsVirtualLink" is used to collect and report alarms for one or more instances of an NS virtual ...
The report of alarm information of NS virtual link is provided via an Alarm associated to the contained object type "Ns" defined in clause 5. 2. 12. The identifier of the NS virtual link, when used in an Alarm, corresponds to "nsVirtualLinkInstanceId" (see clause 8. 3. 3. 10. 2 of ETSI GS NFV-IFA 013 [i. 8]) of the m...
The identifier of the MSNC, when used in an Alarm, corresponds to "msncId" (see clause 8. 2. 2. 6. 2 of ETSI GS NFV-IFA 032 [i. 10]) of the monitored MSNC. 5. 2. 17 CIS cluster The fault monitored object type "CisCluster" is used to collect and report alarms for one or more instances of a CIS cluster. The "managedO...
The identifier of the CIS cluster storage resource, when used in an Alarm, corresponds to "cisClusterStorageId" (see clause 4. 2. 4 of ETSI GS NFV-IFA 036 [i. 13]) of the monitored CIS cluster storage resource. 5. 2. 20 CIS cluster network The fault monitored object type "CisClusterNetwork" is used to collect and r...
The report of alarm information of CIS cluster nodes network resource is provided via an Alarm associated to the contained object type "CisCluster" defined in clause 5. 2. 17. The identifier of the CIS cluster nodes network resource, when used in an Alarm, corresponds to "cisClusterNetworkId" (see clause 4. 2. 4 of E...
7 of ETSI GS NFV-IFA 007 [i. 6] or clause 9. 4. 7 of ETSI GS NFV-IFA 008 [i. 7]) of the monitored compute MCIO. 5. 2. 24 MANO entity The fault monitored object type "ManoEntity" is used to collect and report alarms for NFV-MANO functional entities. The "managedObjectId", when used in an Alarm, corresponds to "manoEn...
27 MANO entity component The fault monitored object type "ManoEntityComponent" is used to collect and report alarms for one or more instances of NFV-MANO entity components which makes up one or multiple NFV-MANO functional entities. <|end_of_text|>
The report of alarm information of MANO entity component is provided via an Alarm associated to the contained object type "ManoEntity" defined in clause 5. 2. 24. The identifier of the MANO Entity Component when used in an Alarm, corresponds to "manoEntityComponentId" (see clause 7. 2. 13. 2 of ETSI GS NFV-IFA 031 [i...
ENVIRONMENTAL_ALARM: an alarm of this type is associated with a condition related to an enclosure in which the equipment resides (as defined by Recommendation ITU-T X. 733 [1]). QOS_ALARM: an alarm of this type is associated with degradation in the quality of service (as defined by Recommendation ITU-T X. 733 [1]). E...
INDETERMINATE: it indicates that the severity level cannot be determined (as defined by Recommendation ITU-T X. 733 [1]). NOTE 1: The referenced ETSI NFV specifications that specify NFV-MANO interfaces include "CLEARED" as one of the enumeration values for "Perceived Severity". However, this value indicates the clear...
The specification of the Alarms adheres to the following structure: • Specification of common definitions applicable to one or more specified Alarms. This includes the definition of which probable causes of Alarms can be mapped to event types and be associated to respective managed object types. • Specification of...
7. 2 Alarms associated to virtualised resources 7. 2. 1 Common definitions 7. 2. 1. 1 Probable causes and fault details Table 7. 2. 1. 1-1 specifies probable causes and fault details that can be associated to alarms applicable to managed object types related to virtualised resources. <|end_of_text|>
NOTE: Entries in table 7. 2. 1. 1-1 are ordered alphabetically per "probable cause". Table 7. 2. 1. 1-1: Probable causes on alarms associated to virtualised resources Probable cause Description Event type Managed object types BIT_ERROR Event related to single/multiple bit errors of the resource associated to the ma...
COMMUNICATIONS_ALARM VirtualNetwork VirtualNetworkInterface NETWORK_QOS Event related to degradation of QoS levels of the network resource, such as jitter and delay degradation. QOS_ALARM VirtualNetwork NFVI_COMPONENT_MAINTENANCE Event related to maintenance of an NFVI component. EQUIPMENT_ALARM VirtualCompute...
Probable cause Description Event type Managed object types NODE_DOWN Event related to the compute server (machine) hosting the associated managed object is down/not available. EQUIPMENT_ALARM VirtualCompute REDUNDANCY Event related to the redundancy configuration of the managed object. EQUIPMENT_ALARM VirtualMem...
EQUIPMENT_ALARM VirtualStorage STORAGE_SMART Event related to the Self-Monitoring Analysis and Reporting Technology (SMART) feature of the storage drive. EQUIPMENT_ALARM VirtualStorage STORAGE_VIRTUAL_DISK_DEGRADED Event related to the performance of the virtual disk. QOS_ALARM VirtualStorage STORAGE_VIRTUAL_D...
7. 2. 2 COMPUTE_WARNING a) Alarm definition identifier: COMPUTE_WARNING. b) Description: The compute server (machine) hosting the virtualised compute resource has potential impeding service impacts, but the virtualised compute resource is still operational. c) Managed object type: VirtualCompute. d) Event type: ...
c) Managed object type: VirtualCompute. d) Event type: The event type associated to the probable cause as specified in table 7. 2. 1. 1-1. e) Perceived severity: WARNING. f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Dependi...
7. 2. 5 COMPUTE_CRITICAL a) Alarm definition identifier: COMPUTE_CRITICAL. b) Description: The compute server (machine) hosting the virtualised compute resource has service affecting conditions and the virtualised compute resource is not fully operational. c) Managed object type: VirtualCompute. d) Event type: T...
7 CPU_MINOR a) Alarm definition identifier: CPU_MINOR. b) Description: One or multiple CPUs supporting the virtual CPU used by the virtualised compute resource have non-service affecting fault conditions. c) Managed object type: VirtualCpu. d) Event type: The event type associated to the probable cause as specif...
- "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer system) where the CPU is enclosed. 7. 2. 8 CPU_MAJOR a) Alarm definition identifier: CPU_MAJOR. b) Description: One or multiple CPUs supporting the virtual CPU used by the virtualised compute resource have service affecting cond...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "cpuId=$cpuId", wherein "$cpuId" indicates the CPU id associated to the issue. - "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer system) where the CPU is...
f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "raid", indicating the redundancy issues are related to Redundant Array of Ind...
b) Description: One or multiple memory modules supporting the virtual memory used by the virtualised compute resource have service affecting conditions, but the memory resource is still operational. c) Managed object type: VirtualMemory. d) Event type: The event type associated to the probable cause as specified in...
- "spare", indicating redundancy issues are related to spare memory. - "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer system) where the memory is enclosed. 7. 2. 13 MEMORY_CRITICAL a) Alarm definition identifier: MEMORY_CRITICAL. b) Description: One or multiple memory modules ...
f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "driveId=$driveId", wherein "$driveId" indicates the drive id associated to th...
- "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer or storage system) where the storage drive is enclosed. 7. 2. 15 STORAGE_MINOR a) Alarm definition identifier: STORAGE_MINOR. b) Description: One or multiple drives supporting the virtual storage have non-service affecting fault ...
f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "driveId=$driveId", wherein "$driveId" indicates the drive id associated to th...
- "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer or storage system) where the storage drive is enclosed. 7. 2. 17 STORAGE_CRITICAL a) Alarm definition identifier: STORAGE_CRITICAL. b) Description: One or multiple drives supporting the virtual storage have service affecting cond...
1-1. e) Perceived severity: WARNING. f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "address=$busId:$deviceId. $functionId",...
- "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer system) where the network device is enclosed. 7. 2. 19 NIC_MINOR a) Alarm definition identifier: NIC_MINOR. b) Description: One or multiple network interface cards supporting the virtual network interface have non-service affect...
d) Event type: The event type associated to the probable cause as specified in table 7. 2. 1. 1-1. e) Perceived severity: MAJOR. f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero...
- "hostId=$hostId", wherein "$hostId" indicates the identifier of the host (computer system) where the network device is enclosed. 7. 2. 21 NIC_CRITICAL a) Alarm definition identifier: NIC_CRITICAL. b) Description: One or multiple network interface cards supporting the virtual network interface have service affe...
d) Event type: The event type associated to the probable cause as specified in table 7. 2. 1. 1-1. e) Perceived severity: WARNING. f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, ze...
7. 2. 23 NETWORK _MINOR a) Alarm definition identifier: NETWORK _MINOR. b) Description: One or multiple networks supporting the virtual network have non-service affecting fault conditions. c) Managed object type: VirtualNetwork. d) Event type: The event type associated to the probable cause as specified in table...
- "port=$portId", wherein the "$portId" is the interface port identifier of the affected network resource devices. - "link=$linkId", wherein the "$linkId" is the link identifier on the affected network resource. 7. 2. 25 NETWORK _CRITICAL a) Alarm definition identifier: NETWORK _CRITICAL. b) Description: One or ...
f) Probable cause: One of the probable causes specified in table 7. 2. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "device=$deviceId", wherein "$deviceId" indicates the affected network resourc...
Table 7. 3. 1. 1-1: Probable causes on alarms associated to VNF instances Probable cause Description Event type Managed object types CERTIFICATE_EXPIRATION Event related to expiration of certificate(s) for the managed object. PROCESSING_ERROR_ALARM Vnf, Vnfc See note 1 CPU_BUS Event related to buses of a CPU ...
PROCESSING_ERROR_ALARM Vnfc See note 1 MEMORY_ECC Event related to changes in states or rates concerning Error Correction Code (ECC) of the memory resource associated to the managed object. PROCESSING_ERROR_ALARM Vnfc See note 1 MEMORY_REDUNDANCY Event related to redundancy configuration of the memory resource...
Probable cause Description Event type Managed object types NETWORK_MEMORY_OVERLOAD Event related to overload in the memory subsystems of a network resource associated to the managed object. PROCESSING_ERROR_ALARM VnfVirtualLink NETWORK_OVERLOAD Event related to overload network input/output on a network resource...
EQUIPMENT_ALARM VnfIntCp, VnfExtCp NONRESOURCE_COMMUNICATIONS_ERROR Event related to communication errors not related to underlying resources associated to the managed object. COMMUNICATIONS_ALARM Vnf, Vnfc, VnfVirtualLink, VnfIntCp, VnfExtCp See note 1 NONRESOURCE_PROCESSING_ERROR Event related to process...
Probable cause Description Event type Managed object types STORAGE_BIT_ERROR Event related to single/multiple bit errors on the storage resource associated to the managed object. PROCESSING_ERROR_ALARM Vnfc See note 1 STORAGE_BLOCK_ERROR Event related to bad blocks on the storage resource associated to the mana...
ENVIRONMENTAL_ALARM Vnfc See note 1 STORAGE_FAILURE_PREDICTION Event related to a predictive failure confirmed on a storage resource associated to the managed object. PROCESSING_ERROR_ALARM Vnfc See note 1 STORAGE_MEMORY Event related memory resources of the storage resource associated to the managed object. P...
Probable cause Description Event type Managed object types STORAGE_SENSOR Event or state change related to sensor of the storage resource associated to the managed object. EQUIPMENT_ALARM Vnfc See note 1 STORAGE_SMART Event related to the Self-Monitoring Analysis and Reporting Technology (SMART) feature of the...
3. 1. 1-1. e) Perceived severity: WARNING. f) Probable cause: One of the probable causes specified in table 7. 3. 1. 1-1 for the applicable managed object type. g) Fault details: None defined. <|end_of_text|>
7. 3. 3 VNF_MINOR a) Alarm definition identifier: VNF_MINOR. b) Description: One or multiple of the underlying resources of the VNF instance are experimenting non-service affecting fault conditions and the VNF instance has non-service affecting fault conditions. c) Managed object type: Vnf. d) Event type: The ev...
1-1 for the applicable managed object type. g) Fault details: None defined. 7. 3. 6 VNFC_WARNING a) Alarm definition identifier: VNFC_WARNING. b) Description: One or multiple of the underlying resources of the VNFC instance have potential impeding service impacts, but the VNFC instance is still operational. c) ...
e) Perceived severity: WARNING. f) Probable cause: One of the probable causes specified in table 7. 3. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "instanceId=$instanceId", wherein "$i...
d) Event type: The event type associated to the probable cause as specified in table 7. 3. 1. 1-1. e) Perceived severity: MAJOR. f) Probable cause: One of the probable causes specified in table 7. 3. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero...
7. 3. 9 VNFC_CRITICAL a) Alarm definition identifier: VNFC_CRITICAL. b) Description: One or multiple of the underlying resources of the VNFC instance have service affecting conditions and the VNFC instance is not fully operational. c) Managed object type: Vnfc. d) Event type: The event type associated to the pro...
- "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the underlying network resource associated to the issue. 7. 3. 11 VNFVIRTUALLINK_MINOR a) Alarm definition identifier: VNFVIRTUALLINK_MINOR. b) Description: One or multiple of the underlying resources of the VNF virtual link are experim...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the VNF virtual link instance id associated to the issue. - "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of th...
f) Probable cause: One of the probable causes specified in table 7. 3. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the VNF virtual link...
7. 3. 14 VNFINTCP_WARNING a) Alarm definition identifier: VNFINTCP_WARNING. b) Description: One or multiple of the underlying resources of the VNF internal CP have potential impeding service impacts, but the VNF internal CP is still operational. c) Managed object type: VnfIntCp. d) Event type: The event type ass...
- "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the underlying network resource associated to the issue. 7. 3. 16 VNFINTCP_MAJOR a) Alarm definition identifier: VNFINTCP_MAJOR. b) Description: One or multiple of the underlying resources of the VNF internal CP have service affecting ...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the VNF internal CPinstance id associated to the issue. - "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the ...
f) Probable cause: One of the probable causes specified in table 7. 3. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the VNF external CP ...
7. 3. 19 VNFEXTCP_MINOR a) Alarm definition identifier: VNFEXTCP_MINOR. b) Description: One or multiple of the underlying resources of the VNF external CPs are experimenting non-service affecting fault conditions and the VNF external CP has non-service affecting fault conditions. c) Managed object type: VnfExtCp....
- "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the underlying network resource associated to the issue. 7. 3. 21 VNFEXTCP_CRITICAL a) Alarm definition identifier: VNFEXTCP_CRITICAL. b) Description: One or multiple of the underlying resources of the VNF external CP have service affec...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the VNF external CP instance id associated to the issue. - "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the u...
COMMUNICATIONS_ALARM NsVirtualLink NETWORK_QOS Event related to degradation of QoS levels of the network resource associated to the managed object type, such as jitter and delay degradation. QOS_ALARM NsVirtualLink NONRESOURCE_COMMUNICATIONS_ERROR Event related to communication errors not related to underlying...
Probable cause Description Event type Managed object types NONRESOURCE_PROCESSING_ERROR Event related to processing errors not related to underlying resources associated to the managed object. PROCESSING_ERROR_ALARM Ns, NsVirtualLink, Sap NONRESOURCE_QOS_ERROR Event related to quality of service errors not re...
If the alarm cannot be correlated to another underlying alarm, the NFVO should set the value to EQUIPMENT_ALARM by default. <|end_of_text|>
7. 4. 2 NS_WARNING a) Alarm definition identifier: NS_WARNING. b) Description: One or multiple of the underlying resources and/or constituents of the NS instance have potential impeding service impacts, but NS instance is still operational. c) Managed object type: Ns. d) Event type: The event type associated to ...
4 NS_MAJOR a) Alarm definition identifier: NS_MAJOR. b) Description: One or multiple of the underlying resources and/or constituents of the NS instance have service affecting conditions, but the NS instance is still operational. c) Managed object type: Ns. d) Event type: The event type associated to the probable...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "constituentId=$constituentId", wherein "$constituentId" indicates the instance id of the NS constituent (VNF, PNF) associated to the issue. 7. 4. 5 NS_CRITICAL a) Alarm definition ident...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the NS virtual link instance id associated to the issue. - "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the...
f) Probable cause: One of the probable causes specified in table 7. 4. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the NS virtual link ...
d) Event type: The event type associated to the probable cause as specified in table 7. 4. 1. 1-1. e) Perceived severity: CRITICAL. f) Probable cause: One of the probable causes specified in table 7. 4. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, z...
7. 4. 10 SAP_WARNING a) Alarm definition identifier: SAP_WARNING. b) Description: One or multiple of the underlying resources of the NS service access point have potential impeding service impacts, but the NS service access point is still operational. c) Managed object type: Sap. d) Event type: The event type as...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the SAP instance id associated to the issue. - "constituentId=$constituentId", wherein "$constituentId" indicates the instance id of the NS...
g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following: - "instanceId=$instanceId", wherein "$instanceId" indicates the SAP instance id associated to the issue. - "constituentId=$constituentId", wherein "$constituentId" indicates the instance id of the NS...
Table 7. 5. 1. 1-1: Probable causes on alarms associated to MSCS Probable cause Description Event type Managed object types ADAPTER_ERROR See note. Associated to network edge points (ports/interfaces) of a network node. EQUIPMENT_ALARM Msnc APPLICATION_SUBSYSTEM_FAILURE See note. Associated to network nodes. PR...
Associated to network edge points (ports/interfaces) of a network node, network nodes and links. EQUIPMENT_ALARM Msnc RECEIVER_FAILURE See note. Associated to network nodes. EQUIPMENT_ALARM Msnc REMOTE_NODE_TRANSMISSION_ERROR See note. Associated to network links. COMMUNICATIONS_ALARM Msnc RESOURCE_NEARING_CA...
Probable cause Description Event type Managed object types STORAGE_CAPACITY_PROBLEM See note. Associated to network nodes. PROCESSING_ERROR_ALARM Msnc TIMING_PROBLEM See note. Associated to network nodes. EQUIPMENT_ALARM Msnc TRANSMIT_FAILURE See note. Associated to network edge points (ports/interfaces) of a...
d) Event type: The event type associated to the probable cause as specified in table 7. 5. 1. 1-1. e) Perceived severity: MINOR. <|end_of_text|>
f) Probable cause: One of the probable causes specified in table 7. 5. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "resourceId=$resourceId", wherein "$resourceId" indicates the identifi...
1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "resourceId=$resourceId", wherein "$resourceId" indicates the identifier of the underlying network node, network edge point or network link. 7. ...
f) Probable cause: One of the probable causes specified in table 7. 5. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero, one or multiple occurrences of the following strings: - "instanceId=$instanceId", wherein "$instanceId" indicates the identifi...
d) Event type: The event type associated to the probable cause as specified in table 7. 5. 1. 1-1. e) Perceived severity: MAJOR. f) Probable cause: One of the probable causes specified in table 7. 5. 1. 1-1 for the applicable managed object type. g) Fault details: Depending on the value of the probable cause, zero...
7. 5. 9 MSNC_CRITICAL a) Alarm definition identifier: MSNC_CRITICAL. b) Description: One or multiple of the underlying resources of the MSNC have service affecting conditions and the MSNC is not fully operational. c) Managed object type: Msnc. d) Event type: The event type associated to the probable cause as spe...
Table 7. 6. 1. 1-1: Probable causes on alarms associated to CIS clusters Probable cause Description Event type Managed object types CERTIFICATE_EXPIRATION Event related to expiration of certificate(s) for the managed object. PROCESSING_ERROR_ALARM CisClusterNode CisClusterStorage CIS_CLUSTER_COMMUNICATION Even...
EQUIPMENT_ALARM Mcco MEMORY_BIT_ERROR Event related to single/multiple bit errors of the memory resource associated to the managed object. PROCESSING_ERROR_ALARM CisClusterNode See note 1 MEMORY_CONFIGURATION Event related to configuration of the memory resource associated to the managed object. PROCESSING_ERR...
Probable cause Description Event type Managed object types NETWORK_CONNECTVITY_SIGNAL Event related to loss or changes in the connectivity signal provided/supported by a network resource associated to the managed object. COMMUNICATIONS_ALARM CisClusterNetwork NETWORK_CPU_OVERLOAD Event related to overload in th...
COMMUNICATIONS_ALARM CisClusterNode See note 1 NIC_PCI_ERROR Event related to a component of a Peripheral Component Interconnect (PCI) device of the network interface associated to the managed object. EQUIPMENT_ALARM CisClusterNode See note 1 NIC_PCI_PARITY_ERROR Event related to PCI parity errors of the netw...
Probable cause Description Event type Managed object types NODE_DOWN Event related to the virtual compute or bare-metal machine associated to the managed object is down/not available. EQUIPMENT_ALARM CisClusterNode See note 1 PROCESSOR_SENSOR Sensor related event or state change on a processor resource associ...
PROCESSING_ERROR_ALARM CisClusterNode CisClusterStorage See notes 1 and 2 STORAGE_DRIVE_ARRAY Event related to storage's drive array associated to the managed object. EQUIPMENT_ALARM CisClusterNode CisClusterStorage See notes 1 and 2 STORAGE_ECC Event related to changes in states or rates concerning Error C...
Probable cause Description Event type Managed object types STORAGE_MEMORY Event related memory resources of the storage resource associated to the managed object. PROCESSING_ERROR_ALARM CisClusterNode CisClusterStorage See notes 1 and 2 STORAGE_PHYSICAL_DISK_DEGRADED Event related to the performance on a physi...