File size: 7,534 Bytes
24599ef
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
# CMFM gradient collapse: localization and fixes

Two things live here: the instrumentation that names the first non-finite
operator, and the fixes to the two operators that could produce one. Nothing
clips gradients, skips a sample, adds jitter, or lowers a loss weight — the
fixes change the operators themselves so their backwards are bounded.

The instrumentation stays on. The fixes are argued from the code, not yet
confirmed against the failing microbatch, so the replay is still worth running.

## The fixes

| what | where | change |
| --- | --- | --- |
| covariance normalizer | `collective.py` | per-mode denominator `std_i * std_j` replaced by the single scalar `trace(group_target_cov) / rank`. The element-wise form was not invariant under a rotation of the collective basis (which is only defined up to one) and gave the least-observed direction a `1/var**2` weight. `collective_variance_rel_floor` existed only to cap that amplification and is removed. |
| mode gauge | `latent.py` | `torch.linalg.qr` replaced by ridge-regularised Cholesky-QR (`latent.mode_gauge_ridge`, default `1e-6`), which yields the same positive-diagonal factor but bounds `‖L⁻¹‖` at `1/sqrt(ridge)` instead of `1/r_ii` |
| orthogonality pressure | `bbflow_module.py` | `mode_orth_loss` and the Gram diagnostics moved from the post-gauge `u_global` (orthonormal by construction, so ~0 always) onto the pre-gauge `raw_modes_global` |

Two consequences worth expecting:

- `mode_orth_loss` was effectively zero and is now a real term. With
  `LAMBDA_MODE_ORTH=1.0` the latent regularizer's scale will change.
- `mode_max_cosine_abs` / `mode_gram_condition` now describe the raw mode head,
  so they will no longer read as perfectly conditioned. That is the point.

## What the failure looks like today

Training dies at `rank=1, epoch=0, global_step=170`. The forward `train_loss` is
finite; ~600 parameter gradients are non-finite at the optimizer step, spanning
the BBFlow embedder, the backbone, the condition adapters, the latent prior and
the collective controller. So a finite forward objective produced a non-finite
backward.

Two operators could do that while passing every forward guard:

1. **Empirical covariance normalization**, [`collective.py`](../bbflow/models/collective.py).
   `covariance_scale = (target_std ⊗ target_std).clamp_min(1e-6)` with
   `target_std = sqrt(observed target variance)`. The guard only rejected
   `target_variance <= 1e-6`, so a variance of, say, `1.4e-6` was accepted and
   `d loss / d pred_trans` picked up a factor of `1 / covariance_scale²` ≈ `1e12`.
   The loss itself stays small — only the gradient explodes. The collective basis
   comes from the q-implied physical covariance and is under no obligation to
   align with what 8 sampled MD frames actually do, so a retained mode having
   near-zero observed variance is expected, not exotic.
   The `target_var=[...]` field in the old log is the *q-implied physical*
   variance from `physical_low_rank_target`, **not** this denominator; the real
   suspect was never logged.
2. **Differentiable masked QR**, [`latent.py`](../bbflow/models/latent.py)
   `_masked_orthonormalize_modes`. QR backward scales like `1/r_ii` while the
   guard only rejected `|r_ii| / scale <= 1e-6`. Worse, `mode_orth_loss` ran on
   the QR *output*, which is orthonormal by construction, so it reported ~0 and
   could not constrain a collapsing raw mode head — nothing kept the QR input
   away from rank deficiency.

`tests/test_cmfm_failure_localization.py` pins both the fixed behaviour and,
with the bound disabled, the original explosion.

## Step 1-3: capture the failing microbatch

These are on by default whenever `latent.collective_enable=true`:

| flag (`experiment.training.*`) | default | effect |
| --- | --- | --- |
| `cmfm_numerics_log_interval` | 50 | console cadence for the numerics line |
| `cmfm_grad_guard` | true | check grads after **every** microbatch on **every** rank |
| `cmfm_capture_failure` | true | keep a CPU copy of the current microbatch |
| `cmfm_dump_state_dict` | true | include pre-step weights in the dump |

Every rank now appends one row per **microbatch** to
`<default_root_dir>/cmfm_numerics_rank{r}.csv`, carrying the quantities that
were missing before:

- `collective_observed_target_variance_min` / `_max` (how degenerate the group
  really was), `collective_covariance_scale_min` (the scalar normalizer actually
  used), `collective_covariance_inverse_scale_max`
- `collective_target_cov_rate_absmax`, `collective_predicted_cov_rate_absmax`,
  `collective_covariance_error_absmax`
- `prior_qr_diag_abs_min`, `prior_qr_rel_diag_min`, `prior_qr_condition_max`
- `collective_update_abs`, `collective_update_absmax`
- batch identity: `rank`, `epoch`, `global_step`, `microbatch`, `pdb_name`,
  `num_res`, `num_particles`, `t_min`, `t_max`, `num_groups`

`_cmfm_grad_guard` runs in `on_after_backward`, i.e. **before** accumulation can
smear the first bad microbatch across the window. When it trips it writes

```
<default_root_dir>/cmfm_failure_dumps/rank{r}_epoch{e}_step{s}_micro{m}.pt
<default_root_dir>/cmfm_failure_dumps/rank{r}_epoch{e}_step{s}_micro{m}.json
```

The `.json` is readable immediately: protein name, `N`, the shared `t`, the
per-particle `trajectory_idx`/`conformation_idx` (the 8 MD frames), the group
ids, the per-group collective diagnostics, and a per-parameter gradient summary.
The `.pt` additionally holds the full corrupted batch (including `trans_sc`) and
the pre-step weights, which is what makes the replay exact — the group sampler
uses unseeded `np.random.choice`, so the frame indices alone cannot reproduce it.

Note: the guard raises on whichever rank fails, which will take down the other
ranks. That is the same behaviour as the existing optimizer-step guard.

## Step 4: attribute the component, then compare bf16 against fp32

```bash
python scripts/cmfm_replay_failure.py \
  --dump  outputs/.../cmfm_failure_dumps/rank1_epoch0_step170_micro3.pt \
  --config outputs/ckpt/.../config.yaml \
  --precision both
```

The script rebuilds `BBFlowModule` from the config, loads the pre-step weights,
runs one forward on the captured microbatch, and backpropagates `official`,
`latent` and `collective` **separately** with `torch.autograd.grad`, so the
buffers never mix. For each it reports the loss, the norm and max of the finite
part of the gradient, and the parameters that came back non-finite. It then
repeats the whole thing in pure fp32.

Read the verdict as:

- only `collective` non-finite, in both precisions → the covariance target is
  mathematically singular on this microbatch;
- only `collective` non-finite in bf16, finite in fp32 → bf16 amplification of an
  already-huge but representable gradient;
- `latent` non-finite → the QR/prior path, not the covariance normalizer;
- `official` non-finite → the failure is not CMFM-specific at all.

Run the replay on a single GPU. Component-wise `autograd.grad` under DDP would
fire the reducer hooks more than once.

## Step 5: what still must not be done

Do not add gradient clipping, sample skipping, jitter, or a lower
`lambda_collective_measure`. Each of those turns a reproducible failure into a
silent one. The two fixes above are not of that kind: they replace an unbounded
operator with a bounded one and leave the forward value unchanged wherever the
input is well conditioned.

If training still dies, the dump plus the replay verdict is the evidence to act
on — not a new bound.