| %% Battery Module Parameters and Documentation | |
| % | |
| % This document details various options available for use in the Battery | |
| % Module Simscape(TM) custom component. | |
| % | |
| % Copyright 2020-2026 The MathWorks, Inc. | |
| %% Battery Module Overview | |
| % | |
| % A Battery Module is defined as a collection of a number of cells in | |
| % series and / or parallel. A Battery (Table-based) block from the Simscape | |
| % Electrical library models the battery cell. You can specify the cell-to-cell | |
| % variations by modifying the relevant parameters inside the custom | |
| % component. Each module has six sides and you can choose from four | |
| % different thermal options for each side. | |
| % | |
| %% *Model Fidelity* | |
| % | |
| % * *Select Model Fidelity* — Modeling compexity of the Battery Module | |
| % component, specified as |Detailed|, |Grouped|, or |Lumped|. |Detailed| | |
| % model tracks each and every cell in the system. |Lumped| model tracks the | |
| % whole module as a single unit or as lumped. |Grouped| model tracks the | |
| % best and the worst cell in the module. The best and the worst cell is | |
| % determined based on the cell-to-cell variation specified in *Effective | |
| % rate of coolant heat transfer from each cell*, *Cell terminal resistance | |
| % R0 variation from baseline*, *Cell Ahr rating variation*, *Cell Self- | |
| % discharge resistance variation from baseline Rleak*, or *External heat*. | |
| % For more information on the model fidelity, see table in the Appendix-A | |
| % section. |Grouped| model working principle is shown in the image below. | |
| % For more information on the |Grouped| model fidelity, see Appendix-B. | |
| % | |
| % <<batteryModuleDoc_groupedModel.png>> | |
| % | |
| % | |
| %% Battery *Cell Electrical* Parameters | |
| % | |
| % For the Battery Cell (Table-based) block in the Simscape Electrical | |
| % library, you can specify these parameters: | |
| % | |
| % * *Vector of temperatures, T* — Temperatures at which the cell or module | |
| % data for temperature-varying properties are tabulated, specified as a | |
| % vector. | |
| % | |
| % * *Single cell Ahr rating, baseline* — Cell capacity at the temperatures | |
| % defined in the *Vector of temperatures, T* parameter, specified as a | |
| % vector. | |
| % | |
| % * *Vector of state of charge values, SOC* — Range of values between 0 and | |
| % 1 at which the cell electrical parameters are defined, specified as a | |
| % vector. | |
| % | |
| % * *No load voltage, V0* — Cell open-circuit potential values at different | |
| % *Vector of state of charge values, SOC* and *Vector of temperatures, T* | |
| % points, specified as a matrix. | |
| % | |
| % * *Current directionality* — Current directionality, specified as | |
| % |Enabled| or |Disabled|. This parameter defines hystersis during charge | |
| % and discharge cycles. | |
| % | |
| % * *Terminal resistance, R0* — Cell ohmic resistance values at different | |
| % *Vector of state of charge values, SOC* and *Vector of temperatures, T* | |
| % points, specified as a matrix. | |
| % | |
| % * *Self-discharge* — Cell self discharge option, specified as |Disabled| | |
| % or |Enabled|. If you set this parameter to |Enabled|, you must then | |
| % specify the value of the *Self-discharge resistance, Rleak(T)* parameter. | |
| % The parameter, specified as resistance, defines a resistance for cell | |
| % leakage at all points defined in the *Vector of temperatures, T* | |
| % parameter. | |
| % | |
| % * *Charge dynamics* — Options to select cell dynamics, specified as | |
| % |no dynamics|, |one time-constant dynamics|, |two time-constant dynamics|, | |
| % |three time-constant dynamics|, |four time-constant dynamics| or |five | |
| % time-constant dynamics|. | |
| % | |
| % * *Polarization resistance* — Polarization resistance values at different | |
| % *Vector of state of charge values, SOC* and *Vector of temperatures, T* | |
| % points, specified as a matrix. You must specify the value of | |
| % *Polarization resistance* parameter based on the value of *Charge | |
| % dynamics* parameter. | |
| % | |
| % * *Time constant* — Time constant at different *Vector of state of charge | |
| % values, SOC* and *Vector of temperatures, T* points, specified as a | |
| % matrix. You must specify the value of *Time constant* parameter based on | |
| % the value of *Charge dynamics* parameter. | |
| % | |
| %% Battery *Cell Capacity Fade* Parameters | |
| % | |
| % If you set the *Fade characteristics* parameter of the Battery (Table- | |
| % based) block to |Equations|, specify the parameters *Number of discharge | |
| % cycles, N*, *Change in no-load voltage after N discharge cycles (%)*, | |
| % *Change in terminal resistance after N discharge cycles (%)*, *Change in | |
| % ampere-hour rating after N discharge cycles (%)* and the *Change in | |
| % polarization resistance after N discharge cycles (%)*. | |
| % | |
| %% Battery *Cell Thermal* Parameters | |
| % | |
| % * *Cell thermal mass* — Thermal mass of a single cell, specified as a | |
| % scalar. | |
| % | |
| % * *Cell thermal conductivity* — Cell through-plane conductivity for |pouch| | |
| % and |can| cells, or the radial conductivity for |cylindrical| cells, | |
| % specified as a scalar. | |
| % | |
| %% Battery *Module Electrical* Parameters | |
| % | |
| % * *Number of series connected cells Ns* — Number of strings in series, | |
| % specified as an integer. | |
| % | |
| % * *Number of parallel connected cells Np* — Number of parallel-cells in | |
| % a string, specified as an integer. | |
| % | |
| % * *Choose cell type* — Type of cell, specified as either |Pouch|, |Can|, | |
| % |Compact cylindrical|, or |Regular cylindrical|. | |
| % | |
| % <<batteryModuleDoc_cellType01.png>> | |
| % | |
| % <<batteryModuleDoc_cellType02.png>> | |
| % | |
| % * *Cell height* — Cell height, specified as a scalar. | |
| % | |
| % * *Cell width* — Cell width for |Pouch| and |Can| cells, specified as a | |
| % scalar. | |
| % | |
| % * *Cell thickness* — Cell thickness for |Pouch| or |Can| cells, specified | |
| % as a scalar. | |
| % | |
| % * *Cell diameter* — Cell diameter for |Compact cylindrical| or |Regular | |
| % cylindrical|, specified as a scalar. | |
| % | |
| % * *Number of cylindrical cells in a straight line* — Number of cylindrical | |
| % cells arranged in a straight line for packaging, specified as an integer. | |
| % | |
| % * *Accessory total resistance* — Resistance that combines all inline | |
| % resistance in a module, specified as a scalar. This resistance is the | |
| % sum of cell tab, busbar, cable and/or weld resistances, specified as a | |
| % scalar. | |
| % | |
| % * *Cell balancing* — Cell balancing method, specified as either |none| or | |
| % |passive|. In this example, this parameter is set to |passive|. Upon | |
| % selection of |passive| cell balancing, four parameters become visible. | |
| % These parameters are: *Shunt resistor*, *Switch closed resistance*, | |
| % *Switch open conductance* and *Switch operation threshold*. Passive cell | |
| % balancing is shown schematically in the figure below: | |
| % | |
| % <<batteryModuleDoc_cellBalancing.png>> | |
| % | |
| %% Battery *Module Thermal* Parameters | |
| % | |
| % * *Select module thermal management* — Whether to activate thermal | |
| % management in the module, specified as either |None| or |Active|. If | |
| % you select *Select module thermal management* to |Active|, the option to | |
| % specify heat transfer on the six sides of the module is visible. If you | |
| % select *Select module thermal management* to |None| is selected, then *Heat | |
| % transfer coefficient to ambient* is visible. All sides of the module lose | |
| % heat at a rate defined by this heat transfer coefficient value. | |
| % | |
| % The figure shows the labels of the six sides of the module. Each side of | |
| % the module has four options for heat transfer — |Detailed thermal | |
| % output|, |Lumped thermal port|, |Thermal lookup table|, or |Convection | |
| % boundary|. | |
| % | |
| % <<batteryModuleDoc_moduleThermal.png>> | |
| % | |
| % * |Detailed thermal output| enables thermal node of each cell to be | |
| % connected to other thermal components and is provided through a output | |
| % node. This is useful when detailed thermal analysis and information for | |
| % every cell is required. Each cell then loses heat at a different rate. | |
| % You can connect a detailed fluids component to the output port of the | |
| % battery to help in design optimization studies (example : cell-to-cell | |
| % cooling variation). | |
| % | |
| % * |Lumped thermal port|, connects every cell to the same thermal node | |
| % externally. | |
| % | |
| % * |Convection Boundary| specifies a convection boundary condition | |
| % on the module face, with its own heat transfer coefficient. | |
| % | |
| % * |Thermal lookup table| method specifies the heat transfer from battery | |
| % cells to the coolant using a lookup table method. The lookup table, for | |
| % thermal resistance (W/K) values at multiple temperature and flowrate | |
| % points, is defined for all the cells in the module. The range of | |
| % temperature and flowrate for coolant are defined in *Vector of | |
| % temperatures for LUT thermal model, Tc* and *Vector of coolant flow rates, | |
| % L*, respectively. The *Effective rate of coolant heat transfer from each | |
| % cell* is a 3-D matrix of size [T,F,C] where, *T* is the size of *Vector | |
| % of temperatures for LUT thermal model, Tc*, *F* is the size of *Vector of | |
| % coolant flow rates, L* and *C* is equal to the number of cells in the | |
| % module, *Ns* X *Np*. The values of the matrix are calculated using | |
| % |Detailed thermal output| or 3-D methods such as computational fluid | |
| % dynamics. The values of the matrix depend on the actual hardware design | |
| % of the cooling system or cold plates in the module. The 3D matrix is | |
| % described schematically in the figure below: | |
| % | |
| % <<batteryModuleDoc_LUTbasedThermal.png>> | |
| % | |
| % The 3D matrix defines thermal resistance values at multiple temperature | |
| % and flowrate points. During the simulation, the actual value is picked | |
| % based on *FlwR* and *FlwT*. *FlwR* and *FlwT* specify coolant flowrate | |
| % and inlet temperature based on the values set. | |
| % | |
| % *FlwR* — Value between 0 and 1, specified as a scalar. The *FlwR* input | |
| % value is used to dynamically choose the right value of the flow rate | |
| % during the simulations. The value of the *FlwR* input defines the actual | |
| % flow rate in the module. In the *Vector of coolant flow rates, L* | |
| % parameter, *FlwR* equal to 0 means no flow, while *FlwR* equal to 1 means | |
| % highest flow rate value. | |
| % | |
| % *FlwT* — Positive or negative value that, when summed to the ambient | |
| % temperature, equals the coolant inlet temperature. A value of +15 for the | |
| % *FlwT* input and 273.15 K at the *Amb* port makes the coolant inlet | |
| % temperature equal to 273.15 + 15 = 288.15K. A value of -15 for the *FlwT* | |
| % input and 273.15 K at the *Amb* makes the coolant inlet temperature equal | |
| % to 273.15 - 15 = 258.15 K. | |
| % | |
| % <<batteryModuleDoc_moduleThermalExample.png>> | |
| % | |
| % | |
| % To open the above example, run the command on MATLAB command prompt: | |
| % uiopen('Overview/batteryModuleDoc_example.slx',1) | |
| % | |
| % | |
| % * *External heat* — External heat input to each cell in a module due to a | |
| % hot component placed near the module, specified as a vector. | |
| % | |
| % | |
| %% Battery Module *Cell-to-Cell Variation* Parameters | |
| % | |
| % * *Vector of initial cell temperature* — Cell initial temperature, | |
| % specified as a vector. | |
| % | |
| % * *Vector of initial cell state of charge* — Cell initial state of | |
| % charge, specified as a vector. | |
| % | |
| % * *Cell Ahr rating variation* — Cell-to-cell variations in cell capacity | |
| % at all *Vector of temperatures, T* points for each cell, specified as a | |
| % vector of scalar values. If you set this array to 1, all cell capacity | |
| % is the same. The array values for a cell are multiplied with the value | |
| % specified in the *Single cell Ahr rating, baseline* parameter to | |
| % calculate the actual capacity or the Ahr rating of the cell. | |
| % | |
| % * *Cell terminal resistance R0 variation from baseline* — Cell-to-cell | |
| % variations in cell terminal resistance, specified as a vector of scalar | |
| % values. If you set this array to 1, all cell terminal resistance values | |
| % are the same. The array values for a cell are multiplied with the value | |
| % specified in the *Terminal resistance, R0* parameter to calculate the | |
| % actual terminal resistance value for the cell. | |
| % | |
| % * *Cell Self-discharge resistance variation from baseline Rleak* — Cell- | |
| % to-cell self-discharge, specified as a vector of scalar values. This | |
| % parameter is visible if *Self-discharge* is |Enabled|. If you set this | |
| % array to 1, all cell self discharge values are the same. The array values | |
| % for a cell are multiplied with the value specified in the *Self-discharge | |
| % resistance, Rleak(T)* parameter to calculate the self-discharge | |
| % resistance value for the cell. | |
| % | |
| %% Appendix-A | |
| % | |
| % <<batteryModuleDoc_appendixA.png>> | |
| % | |
| %% Appendix-B | |
| % | |
| % The best and the worst cell is automatically selected based on the user | |
| % input for: | |
| % | |
| % * *Effective rate of coolant heat transfer from each cell* (if the | |
| % |Thermal lookup table| is selected on a module side for the battery | |
| % thermal management), | |
| % * *Cell terminal resistance R0 variation from baseline*, | |
| % * *Cell Ahr rating variation*, | |
| % * *Cell Self-discharge resistance variation from baseline Rleak* and | |
| % * *External heat* | |
| % | |
| % If the module thermal management does not use the option |Thermal lookup | |
| % table|, the best and the worst cells cannot be selected based on the | |
| % same. The cooling effect variation and best/worst cell cannot be found | |
| % out or determined if |Detailed thermal output| or the |Lumped thermal | |
| % port| is used for module thermal management. In that case, the best and | |
| % worst cells are decided based on: | |
| % | |
| % * *Cell terminal resistance R0 variation from baseline*, | |
| % * *Cell Ahr rating variation*, | |
| % * *Cell Self-discharge resistance variation from baseline Rleak* and | |
| % * *External heat* | |
| % | |
| % The code checks for cell-to-cell variation in the data for these | |
| % parameters and skips the ones that have no variation present. If multiple | |
| % parameters are defined with cell-to-cell variations, the best ad the | |
| % worst cells are decided based on cell indices as per the parameter | |
| % preference list above. These details are present in file | |
| % |getGroupedModelIndexFinal.m|. | |
| % | |
| % In scenarios where multiple parameters are defined with cell-to-cell | |
| % variations, it is important that the cell indices for the best and worst | |
| % cells are same for all parameters, else the variation effect would be | |
| % smoothed out in averaging and group-creation (|Grouped| model fidelity) | |
| % for large modules. You will be able to simulate with warning messages if | |
| % the cell indices for the best and worst cells differ for different | |
| % parameters. | |
| % | |