"request": {
"material": "Silicone",
"airflow_cm_s": 8.0,
"resistance_ratio": 1.327,
"heating_s": 45.0,
"aging_s": 720.0,
"mixing_s": 0.0,
"units": {
"airflow_cm_s": "cm/s",
"resistance_ratio": "1",
"heating_s": "s",
"aging_s": "s",
"mixing_s": "s"
}
},
"response": {
"predicted_alarm_level_reached": true,
"value_kind": "predicted",
"target": "recorded ISS scatter >= 2.0 V",
"units": "boolean",
"model_version": "1.0.0",
"applicable_domain": {
"materials": [
"Kapton",
"Lampwick",
"Pyrell",
"Silicone",
"Teflon"
],
"ranges": {
"airflow_cm_s": [
0.0,
8.1
],
"resistance_ratio": [
1.22,
1.48
],
"heating_s": [
10.0,
120.0
],
"aging_s": [
1.0,
720.0
],
"mixing_s": [
0.0,
8.0
]
},
"campaigns": [
"SAME",
"SAME-R"
]
},
"ood": false,
"ood_reason": "Within empirical condition-distance threshold",
"nearest_distance": 0.0,
"ood_threshold": 9.321957129180975,
"nearest_training_test_id": "SAME:5",
"uncertainty": null,
"interpretation": "Experimental response estimate; no alarm timing or operational safety guarantee."
}
}