| event_id,well,onset,offset,event_type,channels,pud_rationale,detail,duration_days | |
| VOLVE-EV-0000,15/9-F-1 C,2014-04-08,2014-04-20,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,13-day zero-onstream span,13 | |
| VOLVE-EV-0001,15/9-F-1 C,2014-08-19,2014-09-01,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,14-day zero-onstream span,14 | |
| VOLVE-EV-0002,15/9-F-1 C,2014-11-25,2014-11-29,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0003,15/9-F-1 C,2014-11-30,2014-12-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0004,15/9-F-1 C,2014-12-02,2014-12-04,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,3-day zero-onstream span,3 | |
| VOLVE-EV-0005,15/9-F-1 C,2014-12-06,2014-12-31,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,26-day zero-onstream span,26 | |
| VOLVE-EV-0006,15/9-F-1 C,2015-01-01,2015-01-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0007,15/9-F-1 C,2015-01-22,2015-01-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,7-day zero-onstream span,7 | |
| VOLVE-EV-0008,15/9-F-1 C,2015-01-31,2015-02-08,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,9-day zero-onstream span,9 | |
| VOLVE-EV-0009,15/9-F-1 C,2015-02-09,2015-02-10,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0010,15/9-F-1 C,2015-02-28,2015-03-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,18-day zero-onstream span,18 | |
| VOLVE-EV-0011,15/9-F-1 C,2015-03-18,2015-03-19,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0012,15/9-F-1 C,2015-04-02,2015-04-19,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,18-day zero-onstream span,18 | |
| VOLVE-EV-0013,15/9-F-1 C,2015-04-20,2015-04-21,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0014,15/9-F-1 C,2015-05-04,2015-05-21,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,18-day zero-onstream span,18 | |
| VOLVE-EV-0015,15/9-F-1 C,2015-05-22,2015-05-23,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0016,15/9-F-1 C,2015-05-28,2015-06-10,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,14-day zero-onstream span,14 | |
| VOLVE-EV-0017,15/9-F-1 C,2015-06-11,2015-06-12,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0018,15/9-F-1 C,2015-07-02,2015-07-21,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,20-day zero-onstream span,20 | |
| VOLVE-EV-0019,15/9-F-1 C,2015-07-22,2015-07-23,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0020,15/9-F-1 C,2015-08-08,2015-09-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,27-day zero-onstream span,27 | |
| VOLVE-EV-0021,15/9-F-1 C,2015-09-04,2015-09-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0022,15/9-F-1 C,2015-09-21,2015-10-13,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,23-day zero-onstream span,23 | |
| VOLVE-EV-0023,15/9-F-1 C,2015-10-14,2015-10-15,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0024,15/9-F-1 C,2015-10-31,2015-11-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,18-day zero-onstream span,18 | |
| VOLVE-EV-0025,15/9-F-1 C,2015-11-18,2015-11-19,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0026,15/9-F-1 C,2015-12-10,2016-01-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,25-day zero-onstream span,25 | |
| VOLVE-EV-0027,15/9-F-1 C,2016-01-04,2016-01-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0028,15/9-F-1 C,2016-01-21,2016-02-05,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,16-day zero-onstream span,16 | |
| VOLVE-EV-0029,15/9-F-1 C,2016-02-06,2016-02-07,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0030,15/9-F-1 C,2016-02-27,2016-03-16,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,19-day zero-onstream span,19 | |
| VOLVE-EV-0031,15/9-F-1 C,2016-03-17,2016-03-18,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0032,15/9-F-1 C,2016-04-07,2016-04-21,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,15-day zero-onstream span,15 | |
| VOLVE-EV-0033,15/9-F-1 C,2014-10-01,2014-10-14,water_breakthrough,water_cut;water_vol,PUD S4.5.2: injection water breaks through ~2 yr into production; sustained water-cut rise is the documented breakthrough mechanism.,water-cut sustained >=0.5,14 | |
| VOLVE-EV-0034,15/9-F-1 C,2014-04-24,2014-05-24,productivity_loss,oil_vol;choke_pct,PUD S5.3.1/S5.3.4: barium/strontium scaling & asphaltene precipitation reduce productivity; sustained rate decline at stable choke.,oil 1116->768 at stable choke,31 | |
| VOLVE-EV-0035,15/9-F-11,2013-07-08,2013-07-23,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,16-day zero-onstream span,16 | |
| VOLVE-EV-0036,15/9-F-11,2013-07-24,2013-07-25,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0037,15/9-F-11,2013-08-01,2013-08-02,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0038,15/9-F-11,2013-08-03,2013-08-04,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0039,15/9-F-11,2013-08-28,2013-09-01,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0040,15/9-F-11,2013-09-02,2013-09-03,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0041,15/9-F-11,2014-08-20,2014-08-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0042,15/9-F-11,2014-08-25,2014-08-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0043,15/9-F-11,2015-08-27,2015-08-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0044,15/9-F-11,2015-08-31,2015-09-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0045,15/9-F-11,2015-10-27,2015-10-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0046,15/9-F-11,2015-10-29,2015-10-30,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0047,15/9-F-11,2015-10-31,2015-11-02,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,3-day zero-onstream span,3 | |
| VOLVE-EV-0048,15/9-F-11,2015-11-03,2015-11-04,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0049,15/9-F-11,2016-04-21,2016-04-22,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0050,15/9-F-11,2016-04-23,2016-04-24,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0051,15/9-F-11,2015-08-13,2015-08-26,water_breakthrough,water_cut;water_vol,PUD S4.5.2: injection water breaks through ~2 yr into production; sustained water-cut rise is the documented breakthrough mechanism.,water-cut sustained >=0.5,14 | |
| VOLVE-EV-0052,15/9-F-11,2014-03-01,2014-03-31,productivity_loss,oil_vol;choke_pct,PUD S5.3.1/S5.3.4: barium/strontium scaling & asphaltene precipitation reduce productivity; sustained rate decline at stable choke.,oil 1216->686 at stable choke,31 | |
| VOLVE-EV-0053,15/9-F-12,2008-05-31,2008-06-01,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0054,15/9-F-12,2008-06-02,2008-06-03,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0055,15/9-F-12,2008-09-03,2008-09-05,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,3-day zero-onstream span,3 | |
| VOLVE-EV-0056,15/9-F-12,2008-09-06,2008-09-07,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0057,15/9-F-12,2009-03-26,2009-03-29,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0058,15/9-F-12,2009-03-30,2009-03-31,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0059,15/9-F-12,2009-08-30,2009-09-04,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,6 | |
| VOLVE-EV-0060,15/9-F-12,2009-09-05,2009-09-06,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0061,15/9-F-12,2009-09-27,2009-09-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0062,15/9-F-12,2009-10-01,2009-10-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0063,15/9-F-12,2010-08-17,2010-08-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,9-day zero-onstream span,12 | |
| VOLVE-EV-0064,15/9-F-12,2010-08-29,2010-08-30,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0065,15/9-F-12,2011-06-24,2011-06-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,5 | |
| VOLVE-EV-0066,15/9-F-12,2011-07-01,2011-07-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0067,15/9-F-12,2011-07-13,2011-07-14,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0068,15/9-F-12,2011-07-15,2011-07-16,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0069,15/9-F-12,2011-07-17,2011-07-18,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0070,15/9-F-12,2011-07-20,2011-07-21,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0071,15/9-F-12,2011-07-23,2011-07-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0072,15/9-F-12,2011-07-25,2011-07-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0073,15/9-F-12,2011-07-31,2011-08-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0074,15/9-F-12,2011-08-04,2011-08-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0075,15/9-F-12,2011-10-19,2011-11-04,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,16-day zero-onstream span,17 | |
| VOLVE-EV-0076,15/9-F-12,2011-11-05,2011-11-06,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0077,15/9-F-12,2012-08-13,2012-09-27,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,31-day zero-onstream span,46 | |
| VOLVE-EV-0078,15/9-F-12,2012-09-29,2012-09-30,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0079,15/9-F-12,2013-03-13,2013-03-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,12-day zero-onstream span,12 | |
| VOLVE-EV-0080,15/9-F-12,2013-03-25,2013-03-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0081,15/9-F-12,2013-04-03,2013-04-04,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0082,15/9-F-12,2013-04-05,2013-04-09,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,5 | |
| VOLVE-EV-0083,15/9-F-12,2013-06-22,2013-06-23,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0084,15/9-F-12,2013-06-26,2013-06-27,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0085,15/9-F-12,2013-08-01,2013-08-02,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0086,15/9-F-12,2013-08-03,2013-08-04,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0087,15/9-F-12,2013-11-05,2013-11-06,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0088,15/9-F-12,2013-11-07,2013-11-08,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0089,15/9-F-12,2014-01-19,2014-01-23,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0090,15/9-F-12,2014-01-24,2014-01-25,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0091,15/9-F-12,2014-05-09,2014-05-10,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0092,15/9-F-12,2014-05-11,2014-05-12,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0093,15/9-F-12,2014-05-16,2014-05-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,9-day zero-onstream span,9 | |
| VOLVE-EV-0094,15/9-F-12,2014-05-25,2014-05-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0095,15/9-F-12,2014-08-20,2014-08-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0096,15/9-F-12,2014-08-25,2014-08-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0097,15/9-F-12,2014-11-25,2014-11-27,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,3-day zero-onstream span,3 | |
| VOLVE-EV-0098,15/9-F-12,2014-11-28,2014-11-29,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0099,15/9-F-12,2014-11-30,2014-12-31,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,32-day zero-onstream span,32 | |
| VOLVE-EV-0100,15/9-F-12,2015-01-01,2015-01-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0101,15/9-F-12,2015-03-23,2015-03-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0102,15/9-F-12,2015-03-25,2015-03-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0103,15/9-F-12,2015-08-27,2015-08-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0104,15/9-F-12,2015-08-31,2015-09-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0105,15/9-F-12,2016-08-13,2016-09-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,36-day zero-onstream span,36 | |
| VOLVE-EV-0106,15/9-F-12,2010-05-22,2010-06-04,water_breakthrough,water_cut;water_vol,PUD S4.5.2: injection water breaks through ~2 yr into production; sustained water-cut rise is the documented breakthrough mechanism.,water-cut sustained >=0.5,14 | |
| VOLVE-EV-0107,15/9-F-12,2008-02-29,2008-03-30,productivity_loss,oil_vol;choke_pct,PUD S5.3.1/S5.3.4: barium/strontium scaling & asphaltene precipitation reduce productivity; sustained rate decline at stable choke.,oil 2878->1981 at stable choke,31 | |
| VOLVE-EV-0108,15/9-F-12,2008-02-22,2008-02-22,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0109,15/9-F-12,2008-03-27,2008-03-28,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0110,15/9-F-12,2008-05-31,2008-06-01,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0111,15/9-F-12,2008-09-04,2008-09-05,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0112,15/9-F-12,2008-09-09,2008-09-09,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0113,15/9-F-12,2009-03-15,2009-03-15,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0114,15/9-F-12,2009-03-17,2009-03-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0115,15/9-F-12,2009-03-26,2009-03-30,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (5d),5 | |
| VOLVE-EV-0116,15/9-F-12,2009-09-03,2009-09-04,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0117,15/9-F-12,2010-08-22,2010-08-22,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0118,15/9-F-12,2011-07-15,2011-07-15,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0119,15/9-F-12,2011-07-27,2011-07-27,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0120,15/9-F-12,2011-10-21,2011-10-21,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0121,15/9-F-12,2011-11-05,2011-11-05,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0122,15/9-F-12,2011-12-10,2011-12-10,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0123,15/9-F-12,2011-12-29,2011-12-29,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0124,15/9-F-12,2012-01-14,2012-01-14,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0125,15/9-F-12,2012-08-15,2012-09-16,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (23d),33 | |
| VOLVE-EV-0126,15/9-F-12,2015-08-26,2015-08-26,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0127,15/9-F-12,2016-08-16,2016-08-18,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (3d),3 | |
| VOLVE-EV-0128,15/9-F-14,2008-02-12,2008-07-12,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,151-day zero-onstream span,152 | |
| VOLVE-EV-0129,15/9-F-14,2008-07-13,2008-07-14,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0130,15/9-F-14,2008-08-22,2008-08-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,9-day zero-onstream span,9 | |
| VOLVE-EV-0131,15/9-F-14,2008-08-31,2008-09-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0132,15/9-F-14,2009-03-26,2009-03-29,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0133,15/9-F-14,2009-03-30,2009-03-31,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0134,15/9-F-14,2009-04-06,2009-04-07,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0135,15/9-F-14,2009-04-08,2009-04-09,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0136,15/9-F-14,2009-04-10,2009-04-11,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0137,15/9-F-14,2009-04-12,2009-04-13,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0138,15/9-F-14,2009-09-02,2009-09-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0139,15/9-F-14,2009-09-04,2009-09-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0140,15/9-F-14,2009-09-27,2009-09-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0141,15/9-F-14,2009-10-01,2009-10-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0142,15/9-F-14,2010-08-17,2010-08-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,9-day zero-onstream span,12 | |
| VOLVE-EV-0143,15/9-F-14,2010-08-29,2010-08-30,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0144,15/9-F-14,2011-06-24,2011-06-28,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,5 | |
| VOLVE-EV-0145,15/9-F-14,2011-07-01,2011-07-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0146,15/9-F-14,2011-07-13,2011-07-14,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0147,15/9-F-14,2011-07-15,2011-07-16,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0148,15/9-F-14,2011-07-17,2011-07-18,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0149,15/9-F-14,2011-07-20,2011-07-21,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0150,15/9-F-14,2011-07-23,2011-07-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0151,15/9-F-14,2011-07-25,2011-07-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0152,15/9-F-14,2011-07-31,2011-08-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0153,15/9-F-14,2011-08-04,2011-08-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0154,15/9-F-14,2011-10-19,2011-11-04,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,16-day zero-onstream span,17 | |
| VOLVE-EV-0155,15/9-F-14,2011-11-05,2011-11-06,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0156,15/9-F-14,2012-08-13,2012-09-27,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,31-day zero-onstream span,46 | |
| VOLVE-EV-0157,15/9-F-14,2012-09-29,2012-09-30,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0158,15/9-F-14,2013-08-01,2013-08-02,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0159,15/9-F-14,2013-08-03,2013-08-04,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0160,15/9-F-14,2013-10-28,2013-10-29,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0161,15/9-F-14,2013-10-30,2013-10-31,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0162,15/9-F-14,2014-08-20,2014-08-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,5-day zero-onstream span,5 | |
| VOLVE-EV-0163,15/9-F-14,2014-08-25,2014-08-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0164,15/9-F-14,2015-08-27,2015-08-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0165,15/9-F-14,2015-08-31,2015-09-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0166,15/9-F-14,2016-07-14,2016-09-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,66-day zero-onstream span,66 | |
| VOLVE-EV-0167,15/9-F-14,2010-03-29,2010-04-11,water_breakthrough,water_cut;water_vol,PUD S4.5.2: injection water breaks through ~2 yr into production; sustained water-cut rise is the documented breakthrough mechanism.,water-cut sustained >=0.5,14 | |
| VOLVE-EV-0168,15/9-F-14,2008-08-03,2008-09-03,productivity_loss,oil_vol;choke_pct,PUD S5.3.1/S5.3.4: barium/strontium scaling & asphaltene precipitation reduce productivity; sustained rate decline at stable choke.,oil 3118->1661 at stable choke,32 | |
| VOLVE-EV-0169,15/9-F-14,2008-02-15,2008-02-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (3d),3 | |
| VOLVE-EV-0170,15/9-F-14,2008-02-20,2008-02-20,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0171,15/9-F-14,2008-02-22,2008-02-22,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0172,15/9-F-14,2008-02-27,2008-03-05,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (8d),8 | |
| VOLVE-EV-0173,15/9-F-14,2008-03-07,2008-03-07,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0174,15/9-F-14,2008-03-10,2008-03-14,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (5d),5 | |
| VOLVE-EV-0175,15/9-F-14,2008-03-16,2008-03-29,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (14d),14 | |
| VOLVE-EV-0176,15/9-F-14,2008-07-01,2008-07-08,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (8d),8 | |
| VOLVE-EV-0177,15/9-F-14,2012-07-22,2012-07-22,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0178,15/9-F-14,2012-08-15,2012-08-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (3d),3 | |
| VOLVE-EV-0179,15/9-F-14,2012-09-01,2012-09-01,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0180,15/9-F-14,2012-09-17,2012-09-27,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (7d),11 | |
| VOLVE-EV-0181,15/9-F-14,2012-10-19,2012-10-19,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0182,15/9-F-14,2013-03-21,2013-03-21,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0183,15/9-F-14,2013-04-09,2013-04-09,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0184,15/9-F-14,2013-08-01,2013-08-02,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0185,15/9-F-14,2013-10-28,2013-10-29,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0186,15/9-F-14,2013-12-11,2013-12-11,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0187,15/9-F-14,2014-05-09,2014-05-09,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0188,15/9-F-14,2014-08-20,2014-08-24,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (5d),5 | |
| VOLVE-EV-0189,15/9-F-14,2014-12-02,2014-12-23,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (22d),22 | |
| VOLVE-EV-0190,15/9-F-14,2015-01-09,2015-01-10,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0191,15/9-F-14,2015-01-27,2015-01-27,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0192,15/9-F-14,2015-02-04,2015-02-04,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0193,15/9-F-14,2015-08-26,2015-08-26,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0194,15/9-F-14,2015-08-31,2015-09-01,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0195,15/9-F-14,2016-01-03,2016-01-03,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0196,15/9-F-14,2016-07-14,2016-07-30,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (17d),17 | |
| VOLVE-EV-0197,15/9-F-14,2016-08-03,2016-09-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (46d),46 | |
| VOLVE-EV-0198,15/9-F-15 D,2014-01-12,2014-01-15,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0199,15/9-F-15 D,2014-01-16,2014-01-17,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0200,15/9-F-15 D,2014-08-20,2014-09-01,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,13-day zero-onstream span,13 | |
| VOLVE-EV-0201,15/9-F-15 D,2014-09-02,2014-09-03,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0202,15/9-F-15 D,2014-11-26,2014-12-31,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,36-day zero-onstream span,36 | |
| VOLVE-EV-0203,15/9-F-15 D,2015-01-01,2015-01-02,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0204,15/9-F-15 D,2015-03-23,2015-03-24,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0205,15/9-F-15 D,2015-03-25,2015-03-26,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0206,15/9-F-15 D,2015-07-19,2015-08-14,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,27-day zero-onstream span,27 | |
| VOLVE-EV-0207,15/9-F-15 D,2015-08-15,2015-08-16,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0208,15/9-F-15 D,2015-08-27,2015-08-30,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0209,15/9-F-15 D,2015-08-31,2015-09-01,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0210,15/9-F-15 D,2015-11-23,2015-12-08,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,16-day zero-onstream span,16 | |
| VOLVE-EV-0211,15/9-F-15 D,2015-12-09,2015-12-10,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0212,15/9-F-15 D,2016-01-05,2016-01-19,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,15-day zero-onstream span,15 | |
| VOLVE-EV-0213,15/9-F-15 D,2016-01-20,2016-01-21,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0214,15/9-F-15 D,2016-03-25,2016-04-06,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,13-day zero-onstream span,13 | |
| VOLVE-EV-0215,15/9-F-15 D,2016-04-07,2016-04-08,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0216,15/9-F-15 D,2016-05-02,2016-05-03,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,2-day zero-onstream span,2 | |
| VOLVE-EV-0217,15/9-F-15 D,2016-05-04,2016-05-05,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0218,15/9-F-15 D,2016-06-04,2016-06-07,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,4-day zero-onstream span,4 | |
| VOLVE-EV-0219,15/9-F-15 D,2016-06-08,2016-06-09,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0220,15/9-F-15 D,2016-07-07,2016-09-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,73-day zero-onstream span,73 | |
| VOLVE-EV-0221,15/9-F-15 D,2015-12-11,2015-12-24,water_breakthrough,water_cut;water_vol,PUD S4.5.2: injection water breaks through ~2 yr into production; sustained water-cut rise is the documented breakthrough mechanism.,water-cut sustained >=0.5,14 | |
| VOLVE-EV-0222,15/9-F-15 D,2014-02-24,2014-03-26,productivity_loss,oil_vol;choke_pct,PUD S5.3.1/S5.3.4: barium/strontium scaling & asphaltene precipitation reduce productivity; sustained rate decline at stable choke.,oil 251->170 at stable choke,31 | |
| VOLVE-EV-0223,15/9-F-15 D,2014-01-15,2014-01-15,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0224,15/9-F-15 D,2015-08-31,2015-08-31,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0225,15/9-F-15 D,2015-11-19,2015-11-20,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0226,15/9-F-15 D,2016-01-12,2016-01-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (6d),6 | |
| VOLVE-EV-0227,15/9-F-15 D,2016-04-03,2016-04-05,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (3d),3 | |
| VOLVE-EV-0228,15/9-F-15 D,2016-07-08,2016-07-09,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0229,15/9-F-5,2016-04-12,2016-04-19,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,8-day zero-onstream span,8 | |
| VOLVE-EV-0230,15/9-F-5,2016-04-20,2016-04-21,restart_transient,on_stream_hrs;whp;oil_vol,PUD S5.2/S4.5: gas-lift used to restart wells after shut-in; abrupt pressure/rate recovery after a stop is a documented restart signature.,rate recovery post shut-in,2 | |
| VOLVE-EV-0231,15/9-F-5,2016-08-27,2016-09-17,shut_in,on_stream_hrs,PUD S5.3.2/S5.3.6: hydrate & wax risk arises specifically during well shut-in; on_stream_hrs->0 with live well = documented shut-in condition.,15-day zero-onstream span,22 | |
| VOLVE-EV-0232,15/9-F-5,2016-04-13,2016-04-19,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (7d),7 | |
| VOLVE-EV-0233,15/9-F-5,2016-04-22,2016-04-23,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (2d),2 | |
| VOLVE-EV-0234,15/9-F-5,2016-08-28,2016-08-28,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (1d),1 | |
| VOLVE-EV-0235,15/9-F-5,2016-08-30,2016-09-17,gaslift_instability,annulus_press,PUD S5.2: gas-lift wells show annulus-pressure instability; anomalous annulus-pressure deviation is a documented lift-system signature.,annulus z>3 (12d),19 | |