OpenEnv typed models: Observation, Action, Reward β€” V2
"""
from openenv.core.env_server.types import Action, Observation
from typing import Any, Dict, List, Optional
from pydantic import BaseModel, Field
# ── Zone Observation ──────────────────────────────────────────────────────────
class ZoneObservation(BaseModel):
zone_id: str
# ── Thermal readings ──────────────────────────────────────────────────────
cold_aisle_temp_c: float = Field(
...,
description=(
"Primary cold-aisle temperature sensor reading (Β°C). "
"For zones with sensor_confidence < 0.7 this value may be drifted "
"β€” it reflects the same faulty sensor as reported_temp_c. "
"Use hot_aisle_temp_c, supply_air_temp_c, and it_load_kw to "
"cross-check the true thermal state when sensor_confidence is low."
),
)
hot_aisle_temp_c: float = Field(
..., description="Return-air temperature from server exhausts (Β°C). Always accurate."
)
reported_temp_c: float = Field(
...,
description=(
"Secondary sensor reading (Β°C). Typically matches cold_aisle_temp_c; "
"cross-checking both values plus hot_aisle physics can reveal sensor drift."
),
)
supply_air_temp_c: float = Field(
..., description="Actual delivered supply air temperature (Β°C)"
)
supply_air_temp_setpoint_c: float = Field(
..., description="Agent-controlled supply air temperature setpoint [16–26] (Β°C)"
)
# ── Load ──────────────────────────────────────────────────────────────────
it_load_kw: float = Field(..., description="Current IT equipment power draw (kW)")
it_load_pct: float = Field(
..., description="Normalised IT load relative to zone baseline [0-1]"
)
# ── Fan / cooling ─────────────────────────────────────────────────────────
fan_speed_pct: float = Field(..., description="Current fan speed (0-100 %)")
cooling_capacity_kw: float = Field(
..., description="Max cooling capacity at full fan speed (kW)"
)
# ── Environment ───────────────────────────────────────────────────────────
humidity_pct: float = Field(..., description="Relative humidity (%)")
# ── Sensor metadata ───────────────────────────────────────────────────────
sensor_confidence: float = Field(
..., ge=0.0, le=1.0,
description="Reliability weight of this zone's sensor reading [0.0-1.0]"
)
zone_priority: int = Field(
..., ge=0, le=2,
description="Static criticality label: 0=low, 1=medium, 2=critical"
)
# ── Forecast ──────────────────────────────────────────────────────────────
load_forecast_next_hour: float = Field(
default=0.0,
description="Predicted IT load in the next 60 minutes (kW)"
)
# ── Facility Observation ──────────────────────────────────────────────────────
class DCObservation(Observation):
step: int
# ── Time ──────────────────────────────────────────────────────────────────
timestamp_hour: float = Field(..., description="Hour of day [0–24]")
timestamp_day_sin: float = Field(
..., description="sin(2Ο€ Γ— hour/24) β€” cyclical time encoding"
)
timestamp_day_cos: float = Field(
..., description="cos(2Ο€ Γ— hour/24) β€” cyclical time encoding"
)
# ── Weather ───────────────────────────────────────────────────────────────
outside_temp_c: float = Field(..., description="Outdoor dry-bulb temperature (Β°C)")
wet_bulb_temp_c: float = Field(
..., description="Outdoor wet-bulb temperature β€” determines free-cooling potential (Β°C)"
)
# ── Chiller ───────────────────────────────────────────────────────────────
chiller_active: bool
chiller_setpoint_c: float = Field(
..., description="Current chilled-water setpoint [6–15] (Β°C)"
)
chiller_cop: float = Field(..., description="Chiller coefficient of performance")
chiller_fault_detected: bool = Field(
default=False,
description="Observable anomaly signal β€” True when COP has degraded abnormally",
)
chiller_fault_status: str = Field(
default="nominal",
description=(
"Chiller health status: "
"'nominal' = fully operational; "
"'degrading' = COP dropping, still providing partial cooling; "
"'offline' = chiller has failed and provides zero cooling. "
"When 'offline', setting chiller_active=true in your action has no effect."
),
)
# ── Power ─────────────────────────────────────────────────────────────────
ups_efficiency: float = Field(..., description="UPS efficiency [0–1]")
current_pue: float = Field(..., description="Real-time Power Usage Effectiveness (1.0 = perfect)")
free_cooling_potential: float = Field(
default=0.0,
description="Fraction of cooling that could be met by free-air economiser [0–1]"
)
# ── Carbon ────────────────────────────────────────────────────────────────
grid_carbon_intensity: str = Field(
..., description="Human-readable label: low | medium | high | critical_high"
)
carbon_intensity_normalized: float = Field(
..., ge=0.0, le=1.0,
description="Numeric carbon intensity [0.0–1.0] for reward computation"
)
# ── Load phase ────────────────────────────────────────────────────────────
load_curve_phase: str = Field(
default="idle",
description="Current phase of the diurnal load curve: ramp_up | peak | ramp_down | idle"
)
# ── Zones ─────────────────────────────────────────────────────────────────
zones: List[ZoneObservation]
# ── Temporal history buffer ───────────────────────────────────────────────
history: List[Dict[str, Any]] = Field(
default_factory=list,
description=(
"Last 3 step snapshots. Each entry: "
"{cold_aisle_temp, hot_aisle_temp, fan_speed_pct, pue} per zone, "
"flattened as history_t-1, history_t-2, history_t-3"
)
)
# ── Event / context block ─────────────────────────────────────────────────
sla_violation_streak: int = Field(
default=0,
description="Consecutive steps in which any zone was outside the safe temperature band"
)
maintenance_active: bool = Field(
default=False,
description="True if any zone is currently in a maintenance window"
)
maintenance_notes: List[str] = Field(default_factory=list)
upcoming_events: List[str] = Field(default_factory=list)
# ── Active alerts (environment-computed, not agent-injected) ──────────────
active_alerts: List[str] = Field(
default_factory=list,
description=(
"Structured alert strings generated by the environment at each step. "
"Covers: chiller fault/offline, zone overheating/overcooling, "
"sensor faults, temperature trends, efficiency hints, SLA streaks. "
"Agents should act on these before inspecting raw numeric fields."
),
)
# ── Action ────────────────────────────────────────────────────────────────────
class ZoneAdjustment(BaseModel):
zone_id: str
fan_speed_pct: float = Field(
..., ge=0.0, le=100.0,
description="Target fan speed for this zone (0–100 %)"
)
supply_air_temp_setpoint_c: float = Field(
..., ge=16.0, le=26.0,
description="Target supply air temperature setpoint for this zone [16–26] (Β°C)"
)
class DCAction(Action):
"""
Agent action for one environment step.
Three control levers per zone plus one facility-level lever.
All zone adjustments must be submitted together; omitting a zone
leaves its current settings unchanged.
"""
zone_adjustments: List[ZoneAdjustment] = Field(
default_factory=list,
description="Per-zone fan speed and supply air temperature setpoint adjustments"
)
# ── Facility-level levers ─────────────────────────────────────────────────
chiller_setpoint_c: float = Field(
default=10.0, ge=6.0, le=15.0,
description="Facility-wide chilled-water setpoint [6–15] (Β°C)"
)
chiller_active: bool = Field(
default=True,
description=(
"Toggle chiller on/off. Turning off saves significant power but "
"temperatures will rise for 3–5 steps before consequences appear."
)
)
# ── Reasoning (graded in hard task) ──────────────────────────────────────
reasoning: Optional[str] = Field(
default=None,
description=(
"Agent's explanation of its decision. "
"Graded in the hard task β€” coherent crisis reasoning is rewarded; "
"inconsistency between stated reasoning and actual action is penalised."
)
)
# ── Reward breakdown ──────────────────────────────────────────────────────────
class DCReward(BaseModel):
total: float = Field(..., description="Combined reward for this step")
# ── Component rewards ─────────────────────────────────────────────────────
temp_reward: float = Field(
default=0.0,
description="R_temp β€” temperature compliance reward (priority-weighted)"
)
pue_reward: float = Field(
default=0.0,
description="R_pue β€” efficiency reward relative to PID baseline"
)
carbon_reward: float = Field(
default=0.0,
description="R_carbon β€” penalty for high cooling power during dirty-grid periods (≀0)"
)
# ── Penalties ─────────────────────────────────────────────────────────────
safety_penalty: float = Field(
default=0.0,
description="P_safety β€” hard penalty for temperature safety violations (≀0)"
)
roughness_penalty: float = Field(
default=0.0,
description="P_roughness β€” penalty for abrupt action changes (≀0)"
)
# ── Bonus ─────────────────────────────────────────────────────────────────
stability_bonus: float = Field(
default=0.0,
description="B_stability β€” compounding bonus for sustained temperature compliance (β‰₯0)"
)
# ── Legacy / extra ────────────────────────────────────────────────────────
# Kept for backward compatibility with any existing grader consumers
temperature_penalty: float = Field(
default=0.0,
description="Alias for safety_penalty (legacy field β€” prefer safety_penalty)"
)
humidity_penalty: float = Field(
default=0.0,
description="Penalty for humidity violations (≀0)"
)
breakdown: Dict[str, Any] = Field(
default_factory=dict,
description="Per-zone or per-component reward detail for debugging"
)
# ── Step / reset results ──────────────────────────────────────────────────────
class StepResult(BaseModel):
observation: DCObservation
reward: float
reward_detail: DCReward
done: bool
info: Dict[str, Any] = Field(default_factory=dict)
class ResetResult(BaseModel):
observation: DCObservation
info: Dict[str, Any] = Field(default_factory=dict)