Robert Elder commited on
Commit
d4fe9ea
·
1 Parent(s): 9d79212

quantity module UI: updated feedback on exhaustivity

Browse files
data/db-polymer-properties-and-categories.xlsx CHANGED
@@ -1,3 +1,3 @@
1
  version https://git-lfs.github.com/spec/v1
2
- oid sha256:b9a899421ec1071d344636427dcc53c75e0e4fcde3ec27f322faf53607a8c142
3
  size 26083
 
1
  version https://git-lfs.github.com/spec/v1
2
+ oid sha256:52672b90cfa19da89c958cdbdfd6121b3da9abe187e5aedaee0ea503dec05db8
3
  size 26083
quantity_module/templates/quantity_index.html CHANGED
@@ -180,7 +180,7 @@ please see the <a href="{{url_for('.static', filename='RST.html')}}"> RST inform
180
  <p><em>Temperature</em> - Enter the temperature of the extraction experiment in degrees Celsius.
181
  <p><em>Solvent</em> - Select the extraction solvent from the list.
182
  <p><em>Solvent volume</em> - Enter the volume of solvent used for extraction.
183
- <p><em>Swelling amount</em> - Enter the weight percent of the extraction solvent the swollen polymer, accounting for crystallinity, if any (i.e., \( (m_s-m_0)/(m_s-X_c m_0) \times 100 \), where \( m_s \) and \( m_0 \) are the swollen and initial mass, respectively, and \( X_c \) is the crystalline fraction).
184
  <p><em>Partition coefficient</em> - If known, enter the polymer/solvent partition coefficient of the extractable.
185
  If not known, the default worst-case value of 10 can be used for typical device polymers, hydrophobic extractables, and semi- or non-polar extraction solvents.
186
  </div>
 
180
  <p><em>Temperature</em> - Enter the temperature of the extraction experiment in degrees Celsius.
181
  <p><em>Solvent</em> - Select the extraction solvent from the list.
182
  <p><em>Solvent volume</em> - Enter the volume of solvent used for extraction.
183
+ <p><em>Swelling amount</em> - Enter the weight percent of the extraction solvent in the swollen polymer, accounting for crystallinity, if any (i.e., \( (m_s-m_0)/(m_s-X_c m_0) \times 100 \), where \( m_s \) and \( m_0 \) are the swollen and initial mass, respectively, and \( X_c \) is the crystalline fraction).
184
  <p><em>Partition coefficient</em> - If known, enter the polymer/solvent partition coefficient of the extractable.
185
  If not known, the default worst-case value of 10 can be used for typical device polymers, hydrophobic extractables, and semi- or non-polar extraction solvents.
186
  </div>
quantity_module/templates/quantity_report.html CHANGED
@@ -71,7 +71,7 @@
71
  </div>
72
  </div>
73
 
74
- <h2> Exposure </h2>
75
 
76
  <p>
77
  {% if methods[0]=="category" %}
@@ -117,7 +117,13 @@ Swelling = {{swelling}} wt% (used to estimate \( D \))<br>
117
  {{ table | safe }}
118
  </div>
119
 
120
- <p>The progress of the extraction can be expressed through the dimensionless time \( \tau \). For your extraction, \( \tau \) = {{tau}}. Extractions with \( \tau \geq 0.1 \) result in more accurate estimates of the total quantity. When \( \tau \geq 1.0 \), the extracted amount may be used directly as the total quantity if the extraction is diffusion-controlled (i.e., \( \Psi \) is sufficiently large). For example, if \( \Psi > 10 \) and \( \tau \geq 1.0 \) less than 10% of the extractable will remain in the test article, consistent with exhaustive extraction. The total quantity from this tool may be used in the CHRIS exposure modules to estimate clinical exposure.</p>
 
 
 
 
 
 
121
 
122
  {% if M0>=mass_units %}
123
  <p>
 
71
  </div>
72
  </div>
73
 
74
+ <h2> Total Quantity </h2>
75
 
76
  <p>
77
  {% if methods[0]=="category" %}
 
117
  {{ table | safe }}
118
  </div>
119
 
120
+ <!-- <p>The progress of the extraction can be expressed through the dimensionless time \( \tau \). For your extraction, \( \tau \) = {{tau}}. Extractions with \( \tau \geq 0.1 \) result in more accurate estimates of the total quantity. When \( \tau \geq 1.0 \), the extracted amount may be used directly as the total quantity if the extraction is diffusion-controlled (i.e., \( \Psi \) is sufficiently large). For example, if \( \Psi > 10 \) and \( \tau \geq 1.0 \) less than 10% of the extractable will remain in the test article, consistent with exhaustive extraction. The total quantity from this tool may be used in the CHRIS exposure modules to estimate clinical exposure.</p> --!>
121
+ <h3> Notes </h3>
122
+ <ul>
123
+ <li>The progress of the extraction can be expressed through the dimensionless time \( \tau \). For your extraction, \( \tau \) = {{tau}}. Extractions with \( \tau \geq 0.1 \) result in more accurate estimates of the total quantity.</li>
124
+ <li>If the median \( M / M_0 > 0.9 \), the extraction can be considered exhaustive, and the extracted amount may be used directly as the total quantity.</li>
125
+ <li>The total quantity predicted with this tool can be used in the CHRIS exposure modules to estimate clinical exposure.</li>
126
+ </ul>
127
 
128
  {% if M0>=mass_units %}
129
  <p>