mtourville commited on
Commit
c4bcf18
·
verified ·
1 Parent(s): c8d4f57

Manual changes saved

Browse files
Files changed (1) hide show
  1. biotech-cleanroom-facility.html +9 -9
biotech-cleanroom-facility.html CHANGED
@@ -50,7 +50,7 @@
50
  <div class="text-center">
51
  <span class="text-blue-600 font-medium">PHARMACEUTICAL FACILITY</span>
52
  <h1 class="text-4xl md:text-5xl font-bold leading-tight mb-6 text-gray-800">
53
- Grade A & B Pharmaceutical Cleanroom Facility
54
  </h1>
55
  <div class="flex justify-center items-center space-x-4 text-gray-600">
56
  <div class="flex items-center">
@@ -189,11 +189,11 @@
189
  <ul class="space-y-1">
190
  <li class="flex items-center">
191
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
192
- <span>2 × 25,000 CFM MAUs</span>
193
  </li>
194
  <li class="flex items-center">
195
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
196
- <span>13 Recirc AHUs (8K-32K CFM)</span>
197
  </li>
198
  <li class="flex items-center">
199
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
@@ -205,11 +205,11 @@
205
  </li>
206
  <li class="flex items-center">
207
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
208
- <span>Dedicated tool exhaust systems (N+1)</span>
209
  </li>
210
  <li class="flex items-center">
211
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
212
- <span>General exhaust fans (N+1)</span>
213
  </li>
214
  </ul>
215
  </div>
@@ -228,10 +228,10 @@
228
  <div>
229
  <h3 class="text-lg font-bold mb-4 text-blue-600">HVAC Systems</h3>
230
  <ul class="space-y-2 text-gray-600">
231
- <li>2 × 25,000 CFM make-up air handling units</li>
232
- <li>13 custom recirculation AHUs (8,000-32,000 CFM)</li>
233
- <li>Hazardous exhaust system (N+1) + Ethanol exhaust system (N+1)</li>
234
- <li>Dedicated tool exhaust systems (N+1) + General exhaust system (N+1)</li>
235
  <li>HEPA filtration (99.99% @ 0.3μm)</li>
236
  <li>Temperature control: ±0.5°C</li>
237
  <li>Humidity control: ±3% RH</li>
 
50
  <div class="text-center">
51
  <span class="text-blue-600 font-medium">PHARMACEUTICAL FACILITY</span>
52
  <h1 class="text-4xl md:text-5xl font-bold leading-tight mb-6 text-gray-800">
53
+ Design-Build Grade A&B Pharmaceutical Cleanrooms
54
  </h1>
55
  <div class="flex justify-center items-center space-x-4 text-gray-600">
56
  <div class="flex items-center">
 
189
  <ul class="space-y-1">
190
  <li class="flex items-center">
191
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
192
+ <span>(2) × 25,000 CFM MAUs</span>
193
  </li>
194
  <li class="flex items-center">
195
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
196
+ <span>(13) Recirc AHUs (8K-32K CFM)</span>
197
  </li>
198
  <li class="flex items-center">
199
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
 
205
  </li>
206
  <li class="flex items-center">
207
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
208
+ <span>Dedicated Tool Exhaust systems (N+1)</span>
209
  </li>
210
  <li class="flex items-center">
211
  <i data-feather="check" class="w-4 h-4 mr-2 text-blue-600"></i>
212
+ <span>General Exhaust Fans (N+1)</span>
213
  </li>
214
  </ul>
215
  </div>
 
228
  <div>
229
  <h3 class="text-lg font-bold mb-4 text-blue-600">HVAC Systems</h3>
230
  <ul class="space-y-2 text-gray-600">
231
+ <li>(2) × 25,000 CFM make-up air handling units</li>
232
+ <li>(13) custom recirculation AHUs (8,000-32,000 CFM)</li>
233
+ <li>Hazardous Exhaust System (N+1) + Ethanol Exhaust System (N+1)</li>
234
+ <li>Dedicated Tool Exhaust Systems (N+1) + General Exhaust System (N+1)</li>
235
  <li>HEPA filtration (99.99% @ 0.3μm)</li>
236
  <li>Temperature control: ±0.5°C</li>
237
  <li>Humidity control: ±3% RH</li>