Spaces:
Runtime error
Runtime error
| The process is initiated by a switch-over request. | |
| In doing so , the customer transmits his data to the customer service department of the company. | |
| Customer service is a shared service center between the departments Sales and Distribution. | |
| The customer data is received by customer service and based on this data a customer data object is entered into the CRM system. | |
| After customer data has been entered it should then be compared with the internal customer data base and checked for completeness and plausibility. | |
| In case of any errors these should be corrected on the basis of a simple error list. | |
| The comparison of data is done to prevent individual customer data being stored multiple times. | |
| In case the customer does not exist in the customer data base , a new customer object is being created which will remain the data object of interest during the rest of the process flow. | |
| This object consists of data elements such as the customer's name and address and the assigned power gauge. | |
| The generated customer object is then used , in combination with other customer data to prepare the contract documents for the power supplier switch ( including data such as bank connection , information on the selected rate , requested date of switch-over ). | |
| In the following an automated check of the contract documents is carried out within the CIS ( customer information system ) in order to confirm their successful generation. | |
| In case of a negative response , i.e. | |
| the contract documents are not ( or incorrectly ) generated , the causing issues are being analyzed and resolved. | |
| Subsequently the contract documents are generated once again. | |
| In case of a positive response a confirmation document is sent out to the customer stating that the switch-over to the new supplier can be executed. | |
| A request to the grid operator is automatically sent out by the CIS. | |
| It puts the question whether the customer may be supplied by the selected supplier in the future. | |
| The switch-over request is checked by the grid operator for supplier concurrence , and the grid operator transmits a response comment. | |
| In the case of supplier concurrence the grid operator would inform all involved suppliers and demand the resolution of the conflict. | |
| The grid operator communicates with the old supplier and carries out the termination of the sales agreement between the customer and the old supplier ( i.e. | |
| the customer service ( of the new supplier ) does not have to interact with the old supplier regarding termination ). | |
| If there are not any objections by the grid operator ( i.e. | |
| no supplier concurrence ) , customer service creates a CIS contract. | |
| The customer then has the chance to check the contract details and based on this check may decide to either withdraw from the switch contract or confirm it. | |
| Depending on the customer's acceptance / rejection the process flow at customer service either ends ( in case of withdrawal ) or continues ( in case of a confirmation ). | |
| An additional constraint is that the customer can only withdraw from the offered contract within 7 days after the 7th day the contract will be regarded as accepted and the process continues. | |
| The confirmation message by the customer is therefore not absolutely necessary ( as it will count as accepted after 7 days in any way ) but it can speed up the switch process. | |
| On the switch-date , but no later than 10 days after power supply has begun , the grid operator transmits the power meter data to the customer service and the old supplier via messages containing a services consumption report. | |
| At the same time , the grid operator computes the final billing based on the meter data and sends it to the old supplier. | |
| Likewise the old supplier creates and sends the final billing to the customer. | |
| For the customer as well as the grid operator the process ends then. | |
| After receiving the meter data customer service imports the meter data to systems that require the information. | |
| The process of winning a new customer ends here . |