Spaces:
Runtime error
Runtime error
Upload QZZpulse.csv
Browse files- QZZpulse.csv +69 -0
QZZpulse.csv
ADDED
|
@@ -0,0 +1,69 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
title,heading,content,tokens
|
| 2 |
+
Contamination Monitoring Log for GMP QC Lab,Contamination Monitoring Log for GMP QC Lab,"For all locations designated below, record the reading on the Berthold LB124 or Ludlum yellow monitor",22
|
| 3 |
+
Contamination Monitoring Log for GMP QC Lab,Contamination Monitoring Log for GMP QC Lab 0,If reading is greater than twice background then decontamination may be required (see RS 3318).,20
|
| 4 |
+
Contamination Monitoring Log for GMP QC Lab,Contamination Monitoring Log for GMP QC Lab 1,*readings are recorded on Qpulse occurrence “Contamination Monitoring in GMP- QC”,22
|
| 5 |
+
Contamination Monitoring Log for GMP QC Lab,Contamination Monitoring Log for GMP QC Lab 2,Completed forms are to be returned to the RPS for review and storage. Forms to be stored for a period of 2 years.,27
|
| 6 |
+
Contamination Monitoring Log for GMP QC Lab,document number,RS 4030,8
|
| 7 |
+
Contamination Monitoring Log for GMP QC Lab,document version,3,1
|
| 8 |
+
Contamination Monitoring Log for GMP QC Lab,document theme,Radiological Safety Manual,28
|
| 9 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,"For all locations designated below, record the reading on the Berthold LB124 or Ludlum yellow monitor",22
|
| 10 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,Contamination Monitoring Log for Radiopharmaceutical Preparation Lab 1,*This is now a Qpulse occurrence “Contamination Monitoring GMP”,18
|
| 11 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,Contamination Monitoring Log for Radiopharmaceutical Preparation Lab 2,Completed forms are to be returned to the RPS for review and storage. Form to be stored for a period of at least 2 years.,29
|
| 12 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,document number,RS 4044,8
|
| 13 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,document version,3,1
|
| 14 |
+
Contamination Monitoring Log for Radiopharmaceutical Preparation Lab,document theme,Radiological Safety Manual,28
|
| 15 |
+
Contamination Monitoring Log for R&D Lab,Contamination Monitoring Log for R&D Lab,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 16 |
+
Contamination Monitoring Log for R&D Lab,Contamination Monitoring Log for R&D Lab 1,If reading is greater than twice background then decontamination may be required (see RS 3318).,20
|
| 17 |
+
Contamination Monitoring Log for R&D Lab,Contamination Monitoring Log for R&D Lab 2,Forms to be stored for a period of at least 2 years.,14
|
| 18 |
+
Contamination Monitoring Log for R&D Lab,document number,RS 4032,8
|
| 19 |
+
Contamination Monitoring Log for R&D Lab,document version,4,1
|
| 20 |
+
Contamination Monitoring Log for R&D Lab,document theme,Radiological Safety Manual,28
|
| 21 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,Radiation Protection Supervisor,Ensure members of staff remove their gloves and monitor their hands before leaving the Pre-Clinical FacilityEnsure members of staff use appropriate monitors for contamination surveysIt is the most senior individual worker / researcher that is responsible for daily (or as per use case) contamination monitoring at the end of working practice and recorded in the appropriate log sheet,67
|
| 22 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,Operators,"Operators should monitor their hands with a Ludlum model 26-1 (yellow monitor) or a Berthold LB124 (orange monitor) during manipulations at appropriately timed intervals; or using a wall mounted device if nearby. If work is being performed with unsealed source manipulations with close contact, monitoring every 2 minutes is advised. Operators should periodically monitor their protective lenses and monitor their feet before beginning to exit their local working area. Local contamination monitoring of the working area should also be performed before leaving the area.Staff should remove their gloves and monitor their hands, feet and eye protection before leaving the Pre Clinical FacilityStaff should take immediate action when the Berthold Radiation Monitoring System level 1 and level 2 alarms trigger to determine the cause (contamination or exposed radiation sources) in accordance with the Local Rules.",168
|
| 23 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,Method,"Contamination monitor surveys are performed on a daily basis when the facility is used with the results recorded in the contamination-monitoring folder that is kept in the Dispensing Room.
|
| 24 |
+
",36
|
| 25 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,Pre Clinical Areas monitored:,"As per RS 4036Using the Orange Berthold monitors LB124Hold down the on/off button to power upReading should be in Gross CPSUsing the Yellow Ludlum monitors (model 26-1)tap the on/off button to power upTap the U (UNITS) button to obtain counts in CPSAs these monitors are very sensitive allow a few seconds for the reading to settle before recordingMeasure with the monitor 1-2cm above area of surveyRecord all values in CPSAll recordings should be on the Contamination Check sheets (RS 4036)Ensure the Pre-Clinical Facility is clear of radioactive subjects (where possible) and all radioactive sources are securely shieldedIf a reason can be deduced why a high reading is measured please mark with an explanation on the record sheetsIf contamination can be easily disposed (e.g. incopad), dispose of safely and re-survey to check for a reduction in activityWhere there is a very high reading due to contamination and it is not possible to decontaminate, leave the room and put a notice on the door to prevent entry overnight – record this in the contamination sheetMonitoring of the areas for contamination should take place before outside workers have access to ensure area is safe to work in.",256
|
| 26 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,Documentation,RS 2005 Management of Contamination MonitoringRS 4036 Contamination Check for Clinical Facility,19
|
| 27 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,document number,RS 3319,8
|
| 28 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,document version,2,1
|
| 29 |
+
Performing Contamination Monitoring in PETIC Pre Clinical Facility,document theme,Radiological Safety Manual,28
|
| 30 |
+
Contamination Monitoring Log for PET/CT Scanner Room,Contamination Monitoring Log for PET/CT Scanner Room,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 31 |
+
Contamination Monitoring Log for PET/CT Scanner Room,Contamination Monitoring Log for PET/CT Scanner Room 1,Completed forms are to be returned to the RPS for review and storage.,15
|
| 32 |
+
Contamination Monitoring Log for PET/CT Scanner Room,document number,RS 4045,8
|
| 33 |
+
Contamination Monitoring Log for PET/CT Scanner Room,document version,1,1
|
| 34 |
+
Contamination Monitoring Log for PET/CT Scanner Room,document theme,Radiological Safety Manual,28
|
| 35 |
+
Contamination Monitoring Clinical Facility ,Contamination Monitoring Clinical Facility ,Forms to be stored for a period of at least 2 years.,14
|
| 36 |
+
Contamination Monitoring Clinical Facility ,Contamination Monitoring Clinical Facility 1,Contamination checked using BERTHOLD LB124 - GROSS cps,16
|
| 37 |
+
Contamination Monitoring Clinical Facility ,document number,RS 4038,8
|
| 38 |
+
Contamination Monitoring Clinical Facility ,document version,4,1
|
| 39 |
+
Contamination Monitoring Clinical Facility ,document theme,PET Manual,11
|
| 40 |
+
Contamination Monitoring Log for Patient ‘Emergency’ Toilet,Contamination Monitoring Log for Patient ‘Emergency’ Toilet,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 41 |
+
Contamination Monitoring Log for Patient ‘Emergency’ Toilet,Contamination Monitoring Log for Patient ‘Emergency’ Toilet 1,Completed forms are to be returned to the RPS for review and storage. Form to be stored for a period of 2 years.,27
|
| 42 |
+
Contamination Monitoring Log for Patient ‘Emergency’ Toilet,document number,RS 4039,8
|
| 43 |
+
Contamination Monitoring Log for Patient ‘Emergency’ Toilet,document version,2,1
|
| 44 |
+
Contamination Monitoring Log for Patient ‘Emergency’ Toilet,document theme,Radiological Safety Manual,28
|
| 45 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,Radiation Protection Supervisor,"Ensure that the Berthold Radiation Monitoring system is continually reviewed, and all alarms are regularly reviewed.Ensure members of staff monitor their hands or remove their gloves when leaving the Pharmacy Preparation RoomEnsure members of staff use appropriate monitors for contamination surveysIt is the most senior individual researcher / worker who is responsible for daily (or as per use case) contamination monitoring at the end of working practice and recorded in the appropriate log sheet / Qpulse.",93
|
| 46 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,Operators,"Operators should monitor their hands with a Ludlum model 26-1 (yellow monitor) or a Berthold LB124 (orange monitor) during manipulations at appropriately timed intervals. If this is unsealed source manipulations with close contact, every 2 minutes is advised. Operators should periodically monitor their protective lenses and monitor their feet before beginning to exit their local working area. Local contamination monitoring of the working area should also be performed before leaving the area.Staff should monitor their hands when leaving the Pharmacy Production RoomStaff should take immediate action when the Berthold Radiation Monitoring System level 1 and level 2 alarms trigger to determine the cause (contamination or exposed radiation sources) in accordance with the Local Rules.",147
|
| 47 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,Method,"Contamination monitor surveys are performed on a daily basis with the results recorded in the contamination monitoring folder which is kept in the PET/CT control room.Clinical Areas monitored:Injection preparation bench: Background-Glucose Monitor-Bench-TrolleyOrange uptake room Background-Couch-Floor-SinkBlue uptake room Background-Couch-Floor-SinkGreen uptake room Background-Couch-Floor-SinkYellow uptake room Background-Couch-Floor-SinkPatient “cold” toilet Background-WC-Floor-SinkPatient “hot” toilet Background-WC-Floor-SinkPharma Prep Background-Bench-Hatch handle-Trolley-Floor-SinkPET/CT scanning room Background-Table-Floor-SinkUse the Orange Berthold monitors LB124Hold down the on/off button to power upReading should be in Gross CPSUsing the Yellow Ludlum monitors (model 26-1)Hold down the on/off button to power upPress the U button to ensure UNITS are in count rate (cps)As these monitors are very sensitive allow a few seconds for the reading to settle before recordingMeasure with the monitor 1-2cm above area of surveyEnter N for values of 6CPS and under, otherwise record all values above 6CPSAll recordings should be on the Contamination Check sheets (RS 4038)Ensure the Clinical Facility is clear of radioactive patients and all radioactive sources are securely shieldedIf a reason can be deduced why a high reading is measured please mark with an explanation on the record sheetsIf contamination can be easily disposed e.g. an unflushed toilet, re-survey to check for a reduction in activityWhere there is a very high reading, leave the room and put a notice on the door to prevent entry overnight – record this in the contamination sheetMonitoring of the areas for contamination should take place before outside workers have access to ensure area is safe to work in.",439
|
| 48 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,Documentation,RS 2005 Management of Contamination MonitoringRS 4038 Contamination Check table for Clinical Facility,20
|
| 49 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,document number,RS 3321,8
|
| 50 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,document version,1,1
|
| 51 |
+
Performing Contamination Monitoring in PETIC Clinical Facility,document theme,Radiological Safety Manual,28
|
| 52 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,Contamination Monitoring Log for Pre-Clinical Prep Room,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 53 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,Contamination Monitoring Log for Pre-Clinical Prep Room 1,If reading is greater than twice background then decontamination may be required (see RS 3318).,20
|
| 54 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,Contamination Monitoring Log for Pre-Clinical Prep Room 2,Completed forms are to be returned to the RPS for review and storage. Forms to be stored for a period of at least 2 years.,29
|
| 55 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,document number,RS 4036,8
|
| 56 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,document version,4,1
|
| 57 |
+
Contamination Monitoring Log for Pre-Clinical Prep Room,document theme,Radiological Safety Manual,28
|
| 58 |
+
Contamination Monitoring Log for Door Withdrawal Room,Contamination Monitoring Log for Door Withdrawal Room,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 59 |
+
Contamination Monitoring Log for Door Withdrawal Room,Contamination Monitoring Log for Door Withdrawal Room 1,If reading is greater than twice background then decontamination may be required (see RS 3318).,20
|
| 60 |
+
Contamination Monitoring Log for Door Withdrawal Room,Contamination Monitoring Log for Door Withdrawal Room 2,Completed forms are to be returned to the RPS for review and storage. Forms to be stored for a period of at least 2 years.,29
|
| 61 |
+
Contamination Monitoring Log for Door Withdrawal Room,document number,RS4033,6
|
| 62 |
+
Contamination Monitoring Log for Door Withdrawal Room,document version,3,1
|
| 63 |
+
Contamination Monitoring Log for Door Withdrawal Room,document theme,Radiological Safety Manual,28
|
| 64 |
+
Contamination Monitoring Log for R&D QC Lab,Contamination Monitoring Log for R&D QC Lab,"For all locations designated below, record the reading on the Berthold LB124",16
|
| 65 |
+
Contamination Monitoring Log for R&D QC Lab,Contamination Monitoring Log for R&D QC Lab 1,If reading is greater than twice background then decontamination may be required (see RS 3318).,20
|
| 66 |
+
Contamination Monitoring Log for R&D QC Lab,Contamination Monitoring Log for R&D QC Lab 2,Completed forms are to be returned to the RPS for review and storage. Forms to be stored for a period of at least 2 years.,29
|
| 67 |
+
Contamination Monitoring Log for R&D QC Lab,document number,RS 4031,8
|
| 68 |
+
Contamination Monitoring Log for R&D QC Lab,document version,3,1
|
| 69 |
+
Contamination Monitoring Log for R&D QC Lab,document theme,Radiological Safety Manual,28
|