Spaces:
Sleeping
Sleeping
File size: 738 Bytes
e545bf5 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 | profile: City of Calgary SWMR
source_manual:
title: City of Calgary Stormwater Management & Design Manual
edition: 2011
status: historical_baseline_verify_current_amendments
criteria:
trap_low_max_depth_m: 0.50
entrance_grade_margin_m: 0.30
conduit_capacity_review_ratio: 0.80
conduit_capacity_warning_ratio: 0.95
pipe_advisory_velocity_mps: 3.0
pipe_critical_velocity_mps: 4.0
continuity_review_pct: 0.50
continuity_warning_pct: 1.00
depth_velocity_curve:
- [0.5, 0.80]
- [1.0, 0.32]
- [2.0, 0.21]
- [3.0, 0.09]
notes:
- Project-specific SMDP, MDP, pond report, City direction, and current amendments take precedence.
- Values marked as screening criteria are not automatic compliance limits.
|