zaheer140 commited on
Commit
409bf92
·
verified ·
1 Parent(s): 740ef9a

Update agents/live/app/prompts.py

Browse files
Files changed (1) hide show
  1. agents/live/app/prompts.py +2 -1
agents/live/app/prompts.py CHANGED
@@ -84,9 +84,9 @@ When casting a JSON string to numeric for division/math, ALWAYS wrap the extract
84
  Correct: `(a.attributes::jsonb->'data'->>'timestamp')::numeric / 1000`
85
  Wrong: `a.attributes::jsonb->'data'->>'timestamp'::numeric / 1000`
86
 
87
- JSONB OPERATORS RULE (CRITICAL):
88
  - ALWAYS use `->>` to navigate and extract a text field from JSONB: `ad.value::jsonb->>'Temperature'`.
89
  - NEVER use subtraction `-` to extract fields. `-` is ONLY for deleting keys from JSONB. Doing `(ad.value::jsonb - 'Data' - 'temperature')::numeric` WILL FAIL with a database error!
 
90
  - JSON keys are case-sensitive. ColdRooms use capitalized keys: `Temperature` and `Humidity`.
91
 
92
  Available context:
@@ -113,5 +113,6 @@ Requirements:
113
  - FORMATTING: For a single asset, use clean, bolded bullet points. For multiple assets (reports/comparisons), use a Markdown table as instructed in the system message.
114
  - TIME CRITICAL: Always convert long technical timestamps (e.g., '2026-04-03 15:43:11.398') into short, human-friendly times (e.g., '3:43 PM, Apr 3').
115
  - TANK LEVEL CRITICAL: Rows for tank queries will include pre-computed columns: `current_level_ft` (actual liquid level), `percentage_filled` (fill %), and `max_ft` (max capacity). Present these directly. DO NOT perform any arithmetic on tank data. If `current_level_ft` is 0 or null, say the tank is empty.
 
116
  - End with one helpful next suggestion when appropriate and when the system message requires it.
117
  """.strip()
 
84
  Correct: `(a.attributes::jsonb->'data'->>'timestamp')::numeric / 1000`
85
  Wrong: `a.attributes::jsonb->'data'->>'timestamp'::numeric / 1000`
86
 
 
87
  - ALWAYS use `->>` to navigate and extract a text field from JSONB: `ad.value::jsonb->>'Temperature'`.
88
  - NEVER use subtraction `-` to extract fields. `-` is ONLY for deleting keys from JSONB. Doing `(ad.value::jsonb - 'Data' - 'temperature')::numeric` WILL FAIL with a database error!
89
+ - To get the timestamp of a reading, use `ad.timestamp` (which is a native TIMESTAMP column in the `asset_datapoint` table). NEVER try to extract a timestamp from `ad.value` or use subtraction `-` to get a numeric timestamp.
90
  - JSON keys are case-sensitive. ColdRooms use capitalized keys: `Temperature` and `Humidity`.
91
 
92
  Available context:
 
113
  - FORMATTING: For a single asset, use clean, bolded bullet points. For multiple assets (reports/comparisons), use a Markdown table as instructed in the system message.
114
  - TIME CRITICAL: Always convert long technical timestamps (e.g., '2026-04-03 15:43:11.398') into short, human-friendly times (e.g., '3:43 PM, Apr 3').
115
  - TANK LEVEL CRITICAL: Rows for tank queries will include pre-computed columns: `current_level_ft` (actual liquid level), `percentage_filled` (fill %), and `max_ft` (max capacity). Present these directly. DO NOT perform any arithmetic on tank data. If `current_level_ft` is 0 or null, say the tank is empty.
116
+ - ONLINE STATUS: When reporting online devices, include a 'Status' column in the table indicating that each device is '**Online**' and display only its latest sensor reading and timestamp.
117
  - End with one helpful next suggestion when appropriate and when the system message requires it.
118