Thibaut Forest Claude Opus 5 (1M context) commited on
Commit
2662738
·
1 Parent(s): 08031d9

Phase 13: gap/heat/room-cascade plunger hypotheses all rejected by panel

Browse files
Files changed (1) hide show
  1. EXPERIMENTS.md +25 -0
EXPERIMENTS.md CHANGED
@@ -436,6 +436,31 @@ fleet. The building death-rate signal is real but weak exactly where the
436
  misses live, and largely confounded with install batch (~90% of lifetime
437
  variance, phase 6).
438
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
439
  ## Test-look ledger
440
 
441
  8 looks total (now historical - see protocol change above); look 9 = the
 
436
  misses live, and largely confounded with install batch (~90% of lifetime
437
  variance, phase 6).
438
 
439
+ ## Phase 13 - plunger mechanism hypotheses: gaps, heat, room cascade (all rejected)
440
+
441
+ Three user hypotheses for what precedes a fast plunge, each built leak-free
442
+ per (device, origin) over all 168 origins and screened on the blind zone
443
+ (11,599 healthy-voltage pairs / 24 silent deaths), then panel-adjudicated:
444
+
445
+ | hypothesis | features | blind AUC | panel (champ 1702.0) | sel% |
446
+ |---|---|---|---|---|
447
+ | telemetry gaps precede death | gap_max_90 / gap_frac_90 / gap_trend | 0.42 / 0.34 / 0.59 - INVERTED: plungers report MORE cleanly than survivors | 1875.0 | 0.0% |
448
+ | hot-running or temp spikes | temp_mean_life / temp_rise_30 / tmax30_rel / temp_hot_frac_90 | 0.68 / 0.42 / 0.39 / 0.49 - only lifetime heat mildly ages (phase-6 confirmed); recent temp is INVERTED | 1988.0 | 0.1% |
449
+ | room cascade (peer fails -> room heats -> I fail) | room_death_90 / bldg_death_90 / room_peer_temp_rise_30 | 0.54 / 0.52 / 0.37 - peers' temp FALLS before a death, recent peer deaths ~chance | 1871.8 | 0.1% |
450
+
451
+ Champion selected in 99.8% of random and 95% of blocked splits. Even the gap
452
+ family's small additive screen nudge (rng_30 0.843 -> 0.867) becomes +173 in
453
+ CV - three noisy features degrade p42 calibration, and the count rule turns
454
+ that into worse inclusion counts.
455
+
456
+ Mechanism picture after phases 6-13: the fast plunger runs slightly COOLER
457
+ than its own baseline, spikes less, reports cleanly, and shows no
458
+ environmental or neighbourhood stress - but its voltage wobbles (rng_30
459
+ 0.833, the one real precursor, itself unactionable at 0.2% prevalence). This
460
+ is the signature of an internal cell failure, not an external stressor:
461
+ nothing in temperature, telemetry health, or spatial context flags it before
462
+ the plunge starts.
463
+
464
  ## Test-look ledger
465
 
466
  8 looks total (now historical - see protocol change above); look 9 = the