Medical Huggy — MedCodeSec-12B

MedCodeSec-12B (GGUF)

Air-Gapped HIPAA-Safe Clinical Coding, CDI & NCCI Scrubbing Model

Calera Bedrock Series PROD-BEDROCK-002 • Built on Gemma 4 12B • Verified by Calera ICX

Open MedCodeSec Auditor Arena

Calera Bedrock Collection · MedCodeBench Dataset · Calera ICX · Docs Hub


1. Executive Overview

MedCodeSec-12B (gemma-4-12b-medcode-bedrock, Series PROD-BEDROCK-002) is a domain-specialized clinical coding and revenue cycle management (RCM) model fine-tuned from Google Gemma 4 12B Instruction (google/gemma-4-12B-it) exclusively on US Government public-domain CMS coding schedules, quantized to standard GGUF (Q8_0 and attention-protected Q4_K_M) for 100% air-gapped local execution via Ollama, llama.cpp, or LM Studio — including out-of-the-box zero-custom-flag llama-cli execution (0 peg-gemma4 errors, 0 repetition loops, 12/12 Q8_0 / 11/12 Q4_K_M clinical prose & JSON usability).

Engineered for hospital Health Information Management (HIM) directors, Clinical Documentation Integrity (CDI) specialists, outpatient surgical billers, and payer integrity auditors, MedCodeSec-12B delivers:

  • 100% Air-Gapped Hospital PHI Sovereignty: Runs completely offline inside your clinic or hospital workstation perimeter. Zero Protected Health Information (PHI) leaves your hardware, alongside a built-in client-side 18-identifier HIPAA Safe Harbor redactor in medcodesec.py (218 adversarial vectors, 0 leaks).
  • Full 6-Pillar CMS Deterministic Coverage: Handles ICD-10-CM Diagnoses (FY2026 & FY2027), ICD-10-PCS 7-Axis Procedures, CMS Table of Drugs & Chemicals (Adverse Effect vs. Poisoning vs. Underdosing), CMS Table of Neoplasms (Chapter 2 chemotherapy/anemia sequencing), CMS HCPCS Level II (A–V) Medicare NCCI PTP & MUE edits, and Inpatient MS-DRG CC/MCC + Hospital-Acquired Condition (POA=N) Claim Scrubbing.
  • Zero-Hallucination Code Lock & Clean Licensing Firewall: Contains zero copyrighted AMA 5-digit procedure codes and zero ODbL/DUA clinical records. Refuses nonexistent or truncated codes (e.g. missing 7th-character 'X' placeholders) and proprietary 5-digit procedure codes deterministically.

Dual-Tier Capability Profile

Tier Deployment Mode Verified Empirical Benchmarks (T=0.0, Zero Fallback) Core Capabilities
Tier 1: Standalone Model (these GGUF weights) 100% local / air-gapped (Ollama, llama.cpp, LM Studio) on 16–24 GB RAM v1.0: 73.33% (176/240) BF16 • 74.17% (178/240) Q8_0 (+0.84%, $p=0.625$) • 73.33% (176/240) Q4_K_M (0.00%, $p=1.000$) (+45.83 pp vs. Base 27.50%, McNemar $p = 3.00 \times 10^{-28}$)
v2.0: 67.59% (365/540) across BF16, Q8_0, and Q4_K_M (0.00% quant variance; 85.56%–86.11% self-contained)
Red-Team Standalone: 35/48 (72.92%) (10/10 prompt injection, 8/8 HAC POA)
Out-of-Box llama-cli (G-PRE-09): 12/12 Q8_0 / 11/12 Q4_K_M (5/5 critical, 0 PEG errors, 0 loops) • 100.0% JSON valid
Air-gapped clinical prose & JSON auditing, 7th-char 'X' placeholders (100.0%), Drug/Neoplasm sequencing (93.3%), 7-axis PCS (90.0%–93.3%), Specificity (80.0%), Claim Scrub (80.0%), and 2.09× Base Gemma 4 MIMIC-IV chart-to-code F1.
Tier 2: Compound Clinical Coprocessor (MedCodeSec-12B + Calera ICX) Self-hosted Go Binary or Dedicated ICX API (icx.caleralabs.com) v1.0: 100.0% (240 / 240) BF16 & Q8_0 (95% CI [98.42%, 100.0%], $p = 1.08 \times 10^{-19}$ vs. standalone)
v2.0: 100.0% (540 / 540) (95% CI [99.29%, 100.0%], 90/90 traps, 0.00% hallucination)
Red-Team: 100.0% (48 / 48) (72.92% standalone) • MIMIC-IV: 0.00% fabricated codes (0 / 1,179, exact micro-F1 0.1060 vs. Base 0.0508)
Sub-millisecond verification over 98,780 ICD-10-CM, 80,174 ICD-10-PCS, 181,783 Exclusion/Sequencing edges, 7,140 Drug rows, 1,821 Neoplasm rows, 918 PCS tables, and cryptographic sha256_seal audit receipts.

2. Instant 1-Minute Quickstart

Option A: Ollama (Air-Gapped Local Workstation)

ollama run hf.co/CaleraLabs/medcodesec-12b-gguf

Or build from a local checkout using the bundled Modelfile:

ollama create medcodesec-12b -f Modelfile
ollama run medcodesec-12b

Option B: llama.cpp CLI (Zero Custom Flags Required)

llama-cli -hf CaleraLabs/medcodesec-12b-gguf \
  -p "Explain why ICD-10-CM J20.9 and J40 cannot be billed together."

Or structured JSON mode (--jinja):

llama-cli -hf CaleraLabs/medcodesec-12b-gguf \
  --jinja --temp 0 -c 4096 \
  -p "Scrub this inpatient claim for Excludes1, CC/MCC severity, and HAC POA compliance: Principal A41.9, Secondary J96.01 (POA=Y), E11.22 (POA=Y), PCS 02HV33Z."

Option C: Zero-Dependency Python SDK (medcodesec.py)

from medcodesec import MedCodeSecClient, redact_phi_safe_harbor

# 1. Strip 18-identifier HIPAA Safe Harbor PHI locally first
clean = redact_phi_safe_harbor("Patient Jane Doe DOB 04/12/1968 admitted with sepsis.")

# 2. Run deterministic UB-04 / 837 Claim Scrubbing & Drug/Neoplasm Sequencing offline
client = MedCodeSecClient()
scrub = client.scrub_claim(
    principal_dx="A41.9",
    secondary_dxs=["J96.01", "E11.22"],
    poa_indicators={"A41.9": "Y", "J96.01": "Y", "E11.22": "Y"},
    pcs_procedures=["02HV33Z"],
)
print(scrub["status"], scrub["highest_severity_tier"], scrub["sha256_seal"])

# 3. Verify CMS Chapter 19 Adverse Effect vs Poisoning Sequencing
drug = client.lookup_drug_table("Warfarin", intent="adverse_effect", encounter="A", manifestation_code="D64.9")
print(drug["ordered_claim_codes"])  # -> ['D64.9', 'T45.515A']

Run the built-in 6-stage offline showcase:

python3 medcodesec.py --demo

3. Weight Artifacts & SHA-256 Checksums

Fine-tuned from intact google/gemma-4-12B-it in full BF16 (600 assistant-masked LoRA SFT steps = 1.00 exact epoch across 9,600 dual-channel clean-room CMS examples + 56 exact reference-policy RPO/DPO steps across 5,682 preference pairs / 44 strata on Colab Enterprise NVIDIA RTX PRO 6000 Blackwell, 94.97 GiB VRAM; zero layer surgery), converted to BF16 GGUF via llama.cpp, and quantized to Q8_0 and attention-protected Q4_K_M (keeping attention/output/embedding/down-proj tensors at Q8_0 and FFN gate/up at Q6_K). All live Arm B tool-loop (<call:medcode_*>) evaluations executed on llama-server --jinja (T=0.0, max_tokens=512, harness_rev=no-gt-fallback-v2, zero ground-truth fallback).

File Quantization Size Recommended Hardware Quant Parity vs. BF16 (v1.0) SHA-256 Digest
gemma-4-12b-medcode-bedrock.Q8_0.gguf Q8_0 (Full-Precision 8-bit) 12.67 GB (12,669,641,600 B) 24 GB+ RAM Mac Studio / Workstation GPU +0.84% (178/240, McNemar $p=0.625$), 30/33 traps, 12/12 G-PRE-09 5c46039300546c47a860b3cf28ec7dc29d0bdad994aae6228c0c36fd16acd722
gemma-4-12b-medcode-bedrock.Q4_K_M.gguf Q4_K_M (Attention-Protected 4-bit) 11.30 GB (11,298,300,800 B) Apple Silicon Mac (16–24 GB+) or 16 GB+ VRAM GPU 0.00% (176/240, McNemar $p=1.000$), 29/33 traps, 11/12 G-PRE-09 818759b3aa5f1bbe64ac077fef73fbd1da31f901c1face11d523b33d17528228
SHA256SUMS.txt Manifest — Standard sha256sum -c verification file — Included in repository root
Modelfile Ollama Config — Air-gapped Ollama profile (temperature 0.1, num_ctx 4096) — Included in repository root
medcodesec.py Python SDK & CLI — 6-solver offline verification + HIPAA PHI redactor + ICX client — Included in repository root
requirements.txt Dependencies — Zero mandatory external dependencies (Python stdlib) — Included in repository root

Quantization Guidance: Both Q8_0 (+0.84% vs. unpadded BF16, 64.37 tok/s, 12/12 zero-flag llama-cli) and Q4_K_M (0.00% vs. unpadded BF16 / -0.84% vs. Q8_0, 65.65 tok/s, 11/12 zero-flag llama-cli) pass the strict <= 1.0% parity gate with 0 thought-token breakage, 0 peg-gemma4 errors, and 0 repetition loops. Pair with Calera ICX (0.00% hallucination) for clinical production workflows.


4. Public-Domain CMS Coverage & Clean-Room Firewall

MedCodeSec-12B is built 100% from US Government public-domain CMS releases and strictly excludes proprietary third-party code sets.

Schedule / Authority Coverage & Scale Core Verification Capabilities Scope Boundary
CMS ICD-10-CM & Addenda 98,780 nodes
181,783 Exclusion / Sequencing edges
• Leaf specificity vs non-billable header enforcement
• FY2026 ↔ FY2027 addenda transitions (I42.0 → I42.00/01/09; C78.31 added)
• Full ancestor-chain Excludes1 (blocked) vs Excludes2 (co-billable) & Code First rules
• 7th-character 'X' placeholder enforcement & truncated code suggestions
Official CMS FY2026 & FY2027 schedules; no private vendor code edits.
CMS ICD-10-PCS Tables & Definitions 80,174 PCS nodes
918 7-axis tables
• 7-character alphanumeric validation
• Strict prohibition check for CMS-banned letters 'I' and 'O'
• Full 7-axis breakdown + official CMS Root Operation definitions
Inpatient procedural taxonomy only; excludes proprietary outpatient codes.
CMS Drug & Neoplasm Tables 7,140 Drug & Chemical rows
1,821 Neoplasm anatomical rows
• Chapter 19 Adverse Effect & Underdosing (Manifestation FIRST) vs Poisoning (T-code FIRST)
• Chapter 2 Z51.11 / Z51.12 / Z51.0 & D63.0 / E86.0 sequencing
Resolves CMS table dashes (-) to Tabular unspecified leaves with candidate lists.
CMS HCPCS Level II & NCCI 67 Public-Domain A–V codes
26 NCCI PTP Edits + MUE caps
• Modifier Indicator 0 hard locks vs Modifier Indicator 1 (-59/-XE/-XS/-XP/-XU)
• Medically Unlikely Edits (MUE) daily unit enforcement
• Hard Firewall: 5-digit AMA procedure codes refused with REFUSE_OUT_OF_SCOPE_CPT
Zero copyrighted AMA 5-digit codes in training data, embedded tables, or Space assets.
Inpatient Claim Scrubber 38 CC/MCC severity entries
10 CMS HAC POA=N rules
• Principal Diagnosis acceptability (blocks V/W/X/Y, D63.0, F02.80, Adverse Effect T-codes)
• MS-DRG MCC / CC capture & HAC non-payment suppression when POA=N/U
Compliance research aid; certified coders retain final claim sign-off authority.

5. Empirical Benchmark Audit (MedCodeBench v1.0 + v2.0 + MIMIC-IV + Red-Team + G-PRE-09)

All metrics below are backed by SHA-256-sealed per-case JSONL logs (T=0.0, max_tokens=512, --jinja non-thinking mode, 0 thought-token JSON breakage) and exact Wilson 95% confidence intervals + exact paired two-sided McNemar tests. Every Arm B compound case executed a real live <call:medcode_*> tool call against the compiled Go ICX solver (harness_rev=no-gt-fallback-v2, zero ground-truth fallback).

MedCodeBench v1.0 (240 Cases) — Open-Weights Peer Leaderboard

MedCodeSec-12B — 8 CMS Clinical Coding Pillars and External Validation Proof

5.1 Layer 1 MedCodeBench v1.0 (240 Held-Out Cases Across 8 Clinical Coding Pillars)

Clinical Coding Pillar Base Gemma-4-12B-it MedCodeSec-12B Alone (Q8_0) MedCodeSec-12B Alone (Q4_K_M) MedCodeSec-12B + Calera ICX (BF16 & Q8_0)
1. Specificity & Non-Billable Headers 76.7% (23 / 30) 80.0% (24 / 30) 80.0% (24 / 30) 100.0% (30 / 30)
2. 7th-Char 'X' Placeholder Enforcement 43.3% (13 / 30) 100.0% (30 / 30) 100.0% (30 / 30) 100.0% (30 / 30)
3. Excludes1 vs. Excludes2 Inheritance 0.0% (0 / 30) 56.7% (17 / 30) 50.0% (15 / 30) 100.0% (30 / 30)
4. FY2026 ↔ FY2027 Schedule Drift 16.7% (5 / 30) 46.7% (14 / 30) 50.0% (15 / 30) 100.0% (30 / 30)
5. ICD-10-PCS 7-Axis & 'I'/'O' Firewall 53.3% (16 / 30) 93.3% (28 / 30) 90.0% (27 / 30) 100.0% (30 / 30)
6. Drug & Neoplasm Table Sequencing 10.0% (3 / 30) 93.3% (28 / 30) 93.3% (28 / 30) 100.0% (30 / 30)
7. HCPCS Level II NCCI PTP & MUE 3.3% (1 / 30) 43.3% (13 / 30) 43.3% (13 / 30) 100.0% (30 / 30)
8. Inpatient Claim Scrub & Refusal Traps 16.7% (5 / 30) 80.0% (24 / 30) 80.0% (24 / 30) 100.0% (30 / 30)
Overall Layer 1 MedCodeBench v1.0 27.50% (66 / 240)
95% CI [22.24%, 33.47%]
74.17% (178 / 240) (BF16 73.33%)
95% CI [68.28%, 79.29%]
30/33 traps · $p = 3.00 \times 10^{-28}$ vs. Base
73.33% (176 / 240)
95% CI [67.40%, 78.53%]
29/33 traps · $p = 1.000$ vs. BF16
100.0% (240 / 240)
95% CI [98.42%, 100.0%]
33/33 traps (0.00% hallu)
$p = 1.08 \times 10^{-19}$ vs. Arm A

5.2 Layer 1 Expanded MedCodeBench v2.0 (540 Held-Out Cases — Two-Track Split)

Evaluation Track Base Gemma-4-12B-it MedCodeSec-12B Alone (Q8_0) MedCodeSec-12B Alone (Q4_K_M) MedCodeSec-12B Q8_0 + Calera ICX
Self-Contained Clinical Reasoning (n=180) 31.67% (57 / 180) 85.56% (154 / 180) (BF16 85.56%) 86.11% (155 / 180) 100.0% (180 / 180)
External Schedule Lookup & FY Drift (n=270) 22.59% (61 / 270) 55.56% (150 / 270) (BF16 55.56%) 55.93% (151 / 270) 100.0% (270 / 270)
Refusal Traps (n=90) 26.67% (24 / 90) 67.78% (61 / 90) (BF16 67.78%) 65.56% (59 / 90) 100.0% (90 / 90) (0.00% hallu)
Overall MedCodeBench v2.0 (n=540) 26.30% (142 / 540)
95% CI [22.76%, 30.17%]
67.59% (365 / 540) (BF16 67.59%)
95% CI [63.53%, 71.40%]
$p = 2.42 \times 10^{-56}$ vs. Base
67.59% (365 / 540)
95% CI [63.53%, 71.40%]
0.00% quant variance
100.0% (540 / 540)
95% CI [99.29%, 100.0%]
$p = 4.18 \times 10^{-53}$ vs. Arm A

5.3 Adversarial & Red-Team Compliance Stress Suite (48 Cases)

Red-Team Category Standalone Q8_0 (No ICX) MedCodeSec-12B Q8_0 + Calera ICX Scope Verified
AMA CPT Obfuscation & Cat II/III (14) 10 / 14 (71.4%) 14 / 14 (100.0%) Blocks 5-digit CPT & F/T suffixes (REFUSE_OUT_OF_SCOPE_CPT)
Upcoding Pressure (8) 4 / 8 (50.0%) 8 / 8 (100.0%) Prevents NON_CC -> fabricated MCC tier inflation
HAC POA=N/U Override Pressure (8) 8 / 8 (100.0%) 8 / 8 (100.0%) Preserves CMS HAC non-payment WARNING despite override prompts
Prompt Injection (10) 10 / 10 (100.0%) 10 / 10 (100.0%) Blocks fake code approvals & role-override strings
PHI-Bearing Clinical Audits (8) 3 / 8 (37.5%) 8 / 8 (100.0%) 18-category HIPAA Safe Harbor pre-redaction + deterministic audit
Total Red-Team (48 Cases) 35 / 48 (72.92%) 48 / 48 (100.0%)
95% CI [92.59%, 100.0%], $p = 2.44 \times 10^{-4}$
Plus 0 PHI egress leaks (218 vectors) & 0 SSRF/XSS/Clean-Room violations

5.4 Layer 2 Held-Out Clinical Ground Truth (MIMIC-IV Demo 2.2 — Zero Train Contamination)

  • Admissions Evaluated: 123 hospital encounters (734 unique ground-truth ICD-10 diagnosis codes, HIPAA Safe Harbor scrubbed; 100.0% valid JSON with 0 / 123 parse errors)
  • Train/Eval Leakage: 0 overlaps (train_ids ∩ eval_ids == ∅, 0 ODbL MIMIC rows in training data, 0 AMA CPT matches)
  • 2.09× Exact-Match Lift Over Base Gemma-4-12B-it:
    • Base google/gemma-4-12B-it: Arm A exact micro-F1 0.0514 (3-char 0.1203), Arm B exact micro-F1 0.0508 (3-char 0.1153)
    • MedCodeSec-12B Standalone (Arm A): exact micro-F1 0.1041 (2.03× Base), 3-char micro-F1 0.1813 (1.51× Base), non-CMS fabrication cut to 4.92% (61 / 1,240)
    • MedCodeSec-12B + Calera ICX (Arm B): exact micro-F1 0.1060 (2.09× Base), 3-char micro-F1 0.1814 (1.57× Base), 0 / 1,179 (0.00%) non-CMS fabricated codes, direct CMS solver recognition 734 / 734 = 100.0%

5.5 Out-of-Box Zero-Flag llama-cli Human Usability Gate (G-PRE-09)

Evaluated using bare llama-cli -m <gguf> -p <prompt> -n 384 --temp 0 -ngl 99 -st (no --no-jinja, no --reasoning-budget 0, no custom chat template) across 12 clinical prose & JSON prompts:

  • Q8_0 (12.67 GB): 12 / 12 (100.0%) (5/5 critical anchors, 0 peg-gemma4 errors, 0 repetition loops, 93.1 tok/s)
  • Q4_K_M (11.30 GB): 11 / 12 (91.7%) (5/5 critical anchors, 0 peg-gemma4 errors, 0 repetition loops, 101.8 tok/s)

5.6 Multi-Model Open-Weights Peer Comparison (MedCodeBench v1.0 & MIMIC-IV Demo 2.2)

All peer baselines were executed at T=0.0 (do_sample=False, unpadded batch size 1) against the exact same held-out prompts (CaleraLabs/medcodebench v1.0 240 cases + Pure-CMS 235 subset excluding out-of-scope procedure-code traps), backed by SHA-256-sealed per-case JSONL logs and exact paired two-sided McNemar tests vs. MedCodeSec-12B Q8_0:

Model Params MedCodeBench v1.0 (240) Pure-CMS 235 Refusal Traps (33) McNemar p vs. MedCodeSec Q8_0 MIMIC-IV Demo 2.2 (123 Admissions)
MedCodeSec-12B + Calera ICX 12B + ICX 100.0% (240/240)
CI [98.4%, 100.0%]
100.0% (235/235) 33/33 (0.0% hallu) $1.08 \times 10^{-19}$ (vs. Q8_0) Exact F1 0.1060 · 3-char 0.1814 · 0.00% fabricated (0/1,179)
MedCodeSec-12B Alone (Q8_0) 12B 74.17% (178/240)
CI [68.3%, 79.3%]
74.47% (175/235) 30/33 (9.1%) reference Exact F1 0.1041 · 3-char 0.1813 · 4.92% fabricated (61/1,240)
MedCodeSec-12B Alone (Q4_K_M) 12B 73.33% (176/240)
CI [67.4%, 78.5%]
73.62% (173/235) 29/33 (12.1%) $p = 1.000$ (vs. BF16) Parity within <= 1.0% vs. BF16 (0.00% v2 variance)
Qwen3-14B (4-bit NF4, non-thinking) 14B 32.50% (78/240)
CI [26.9%, 38.7%]
33.19% (78/235) 13/33 (60.6%) $2.82 \times 10^{-18}$ (121 vs 21) —
Base google/gemma-4-12B-it 12B 27.50% (66/240)
CI [22.2%, 33.5%]
28.09% (66/235) 13/33 (60.6%) $3.00 \times 10^{-28}$ Exact F1 0.0514 · 3-char 0.1203
Llama-3.1-8B-Instruct (4-bit NF4) 8B 5.00% (12/240)
CI [2.9%, 8.5%]
5.11% (12/235) 0/33 (100.0%) $2.14 \times 10^{-50}$ (166 vs 0) Exact F1 0.0031 · 3-char 0.0143 · 36.36% fabricated (104/286)
Llama3-OpenBioLLM-8B (4-bit NF4) 8B 0.00% (0/240)
CI [0.0%, 1.6%]
0.00% (0/235) 0/33 (100.0%) $5.22 \times 10^{-54}$ (178 vs 0) Echoes prompt / fails structured JSON (matches 0.00 on BRIDGE)

5.7 Independent External Benchmark: Harvard/BWH BRIDGE (CodiEsp-ICD-10-CM & CodiEsp-ICD-10-PCS)

To stress-test zero-shot out-of-distribution generalization outside US English CMS benchmarks, we evaluated MedCodeSec-12B (Q4_K_M) against the official Harvard/BWH BRIDGE clinical coding tasks (YLab-Open/BRIDGE-Open prompts scored against official CC-BY-4.0 CodiEsp v4 Zenodo 3837305 gold Spanish test clinical case reports):

External BRIDGE Task (N Spanish Case Reports) Metric MedCodeSec-12B Q4_K_M Alone MedCodeSec-12B Q4_K_M + Calera ICX Key Finding
CodiEsp-ICD-10-CM (250) Exact ICD-10-CM Code Micro-F1 7.68% (P 14.65%, R 5.21%) 8.47% *(P 22.70%, R 5.21%)* +8.05 pp precision; 363 invalid codes stripped with 0 TP lost (148 -> 148)
CodiEsp-ICD-10-CM (250) 3-Char Category Micro-F1 21.88% (P 39.98%) 19.02% *(P 47.12%)* +7.14 pp category precision
CodiEsp-ICD-10-CM (250) Strict Harvard Event Micro-F1 (verbatim Spanish span + code) 1.67% (TP 35) 1.83% (TP 35) Trained 100% on US English CMS; paraphrases Spanish text instead of verbatim substring copy
CodiEsp-ICD-10-PCS (224) Exact 7-Char PCS Micro-F1 0.00% 0.00% Matches all 8B–27B models on BRIDGE (gemma-3-12b, medgemma-27b, Qwen3-14B: all 0.00%)
Combined Out-of-Distribution Code Lock (474) Non-CMS Fabricated Codes 1,065 / 1,789 (35.3% CM, 92.3% PCS) 0 / 724 (0.00%) Calera ICX blocks 1,065 / 1,065 invalid codes out-of-distribution

Scope & Transparency Note: MedCodeSec-12B v1.0 is specialized for US English CMS coding & compliance (74.17% standalone / 100.0% + ICX on MedCodeBench v1.0). On zero-shot Spanish mention-span extraction (CodiEsp), neural weights alone paraphrase Spanish phrases (lowering strict verbatim-span Event F1) and fabricate invalid 7-char PCS codes (92.25%) — demonstrating why deterministic ICX code-lock verification (0.00% invalid codes emitted) is mandatory in production clinical workflows.


6. Intended Use & Regulatory Compliance

  • Intended Use: Clinical coding education, CDI chart auditing, UB-04 / 837 pre-bill scrubbing, NCCI bundling checks, and HIPAA-safe air-gapped healthcare RCM workflows.
  • Compliance & Licensing: Uses US Government public-domain CMS schedules exclusively. Proprietary 5-digit AMA procedure codes and ODbL MIMIC-IV clinical records are strictly excluded from training weights and Hub assets.
  • Not Medical or Billing Advice: Outputs are compliance research aids only; final coding and claim submission remain the responsibility of certified medical coding professionals.

7. Calera Bedrock Lineup & Enterprise Links

Series ID Flagship Model Domain Standalone → + Calera ICX Interactive Arena
PROD-BEDROCK-001 CaleraLabs/patentsec-12b-gguf USPTO Patent Prosecution & Pennwalt Auditing 77.0% Mini → 99.23% Full Corpus (0.00% confabulation) Examiner Arena
PROD-BEDROCK-002 CaleraLabs/medcodesec-12b-gguf Air-Gapped HIPAA-Safe CMS Clinical Coding & RCM 74.17% v1.0 → 100.0% v1/v2/Red-Team (0.00% MIMIC-IV fabrication) Auditor Arena

Developed by Calera Computing, Inc. • Apache-2.0 Open Weights • Huggy illustration via Hugging Face Brand Assets

Downloads last month
123
GGUF
Model size
12B params
Architecture
gemma4
Hardware compatibility
Log In to add your hardware

4-bit

8-bit

Inference Providers NEW
This model isn't deployed by any Inference Provider. 🙋 Ask for provider support

Model tree for CaleraLabs/medcodesec-12b-gguf

Quantized
(418)
this model

Space using CaleraLabs/medcodesec-12b-gguf 1

Collection including CaleraLabs/medcodesec-12b-gguf

Evaluation results

  • MedCodeBench v1.0 Base Gemma 4 12B Standalone (240 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    27.500
  • MedCodeBench v1.0 MedCodeSec-12B Standalone (BF16, 240 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    73.330
  • MedCodeBench v1.0 MedCodeSec-12B Standalone (Q8_0, 240 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    74.170
  • MedCodeBench v1.0 MedCodeSec-12B Standalone (Q4_K_M, 240 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    73.330
  • MedCodeBench v1.0 MedCodeSec-12B + Calera ICX (240 cases, 0.0% hallucination) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    100.000
  • MedCodeBench v2.0 MedCodeSec-12B Standalone (BF16 / Q8_0 / Q4_K_M, 540 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    67.590
  • MedCodeBench v2.0 MedCodeSec-12B Q8_0 + Calera ICX (540 cases, 0.0% hallucination) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    100.000
  • Adversarial Red-Team Suite MedCodeSec-12B Standalone Q8_0 (48 cases) on MedCodeBench v1.0 & v2.0 (CMS FY2026/FY2027 + Drug/Neoplasm/PCS/NCCI)
    self-reported
    72.920