EPlus-LLM commited on
Commit
25e7ba2
·
verified ·
1 Parent(s): c535879

Update v2_nextpart.idf

Browse files
Files changed (1) hide show
  1. v2_nextpart.idf +0 -41
v2_nextpart.idf CHANGED
@@ -216,21 +216,6 @@ Building,
216
  , !- Maximum Number of Warmup Days
217
  ; !- Minimum Number of Warmup Days
218
 
219
-
220
- ZoneControl:Thermostat,
221
- Thermal Zone 1 Thermostat, !- Name
222
- Thermal Zone 1, !- Zone or ZoneList Name
223
- Thermostat Schedule, !- Control Type Schedule Name
224
- ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
225
- Thermostat Setpoint Dual Setpoint, !- Control 1 Name
226
- , !- Control 2 Object Type
227
- , !- Control 2 Name
228
- , !- Control 3 Object Type
229
- , !- Control 3 Name
230
- , !- Control 4 Object Type
231
- , !- Control 4 Name
232
- 0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
233
-
234
  Schedule:Compact,
235
  Thermostat Schedule, !- Name
236
  Thermostat Schedule Type Limits, !- Schedule Type Limits Name
@@ -344,32 +329,6 @@ Schedule:Day:Interval,
344
  24:00, !- Time 1 {hh:mm}
345
  26.7; !- Value Until Time 1
346
 
347
- Sizing:Zone,
348
- Thermal Zone 1, !- Zone or ZoneList Name
349
- SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
350
- 14, !- Zone Cooling Design Supply Air Temperature {C}
351
- 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
352
- SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
353
- 40, !- Zone Heating Design Supply Air Temperature {C}
354
- 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
355
- 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
356
- 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
357
- Ventilation, !- Design Specification Outdoor Air Object Name
358
- , !- Zone Heating Sizing Factor
359
- , !- Zone Cooling Sizing Factor
360
- DesignDay, !- Cooling Design Air Flow Method
361
- 0, !- Cooling Design Air Flow Rate {m3/s}
362
- 0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
363
- 0, !- Cooling Minimum Air Flow {m3/s}
364
- 0, !- Cooling Minimum Air Flow Fraction
365
- DesignDay, !- Heating Design Air Flow Method
366
- 0, !- Heating Design Air Flow Rate {m3/s}
367
- 0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
368
- 0.1415762, !- Heating Maximum Air Flow {m3/s}
369
- 0.3, !- Heating Maximum Air Flow Fraction
370
- , !- Design Specification Zone Air Distribution Object Name
371
- No; !- Account for Dedicated Outdoor Air System
372
-
373
  Schedule:Constant,
374
  Always_On, !- Name
375
  , !- Schedule Type Limits Name
 
216
  , !- Maximum Number of Warmup Days
217
  ; !- Minimum Number of Warmup Days
218
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
219
  Schedule:Compact,
220
  Thermostat Schedule, !- Name
221
  Thermostat Schedule Type Limits, !- Schedule Type Limits Name
 
329
  24:00, !- Time 1 {hh:mm}
330
  26.7; !- Value Until Time 1
331
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
332
  Schedule:Constant,
333
  Always_On, !- Name
334
  , !- Schedule Type Limits Name