Update v2_nextpart.idf
Browse files- v2_nextpart.idf +0 -41
v2_nextpart.idf
CHANGED
|
@@ -216,21 +216,6 @@ Building,
|
|
| 216 |
, !- Maximum Number of Warmup Days
|
| 217 |
; !- Minimum Number of Warmup Days
|
| 218 |
|
| 219 |
-
|
| 220 |
-
ZoneControl:Thermostat,
|
| 221 |
-
Thermal Zone 1 Thermostat, !- Name
|
| 222 |
-
Thermal Zone 1, !- Zone or ZoneList Name
|
| 223 |
-
Thermostat Schedule, !- Control Type Schedule Name
|
| 224 |
-
ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type
|
| 225 |
-
Thermostat Setpoint Dual Setpoint, !- Control 1 Name
|
| 226 |
-
, !- Control 2 Object Type
|
| 227 |
-
, !- Control 2 Name
|
| 228 |
-
, !- Control 3 Object Type
|
| 229 |
-
, !- Control 3 Name
|
| 230 |
-
, !- Control 4 Object Type
|
| 231 |
-
, !- Control 4 Name
|
| 232 |
-
0; !- Temperature Difference Between Cutout And Setpoint {deltaC}
|
| 233 |
-
|
| 234 |
Schedule:Compact,
|
| 235 |
Thermostat Schedule, !- Name
|
| 236 |
Thermostat Schedule Type Limits, !- Schedule Type Limits Name
|
|
@@ -344,32 +329,6 @@ Schedule:Day:Interval,
|
|
| 344 |
24:00, !- Time 1 {hh:mm}
|
| 345 |
26.7; !- Value Until Time 1
|
| 346 |
|
| 347 |
-
Sizing:Zone,
|
| 348 |
-
Thermal Zone 1, !- Zone or ZoneList Name
|
| 349 |
-
SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
|
| 350 |
-
14, !- Zone Cooling Design Supply Air Temperature {C}
|
| 351 |
-
11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
|
| 352 |
-
SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
|
| 353 |
-
40, !- Zone Heating Design Supply Air Temperature {C}
|
| 354 |
-
11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
|
| 355 |
-
0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
| 356 |
-
0.008, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir}
|
| 357 |
-
Ventilation, !- Design Specification Outdoor Air Object Name
|
| 358 |
-
, !- Zone Heating Sizing Factor
|
| 359 |
-
, !- Zone Cooling Sizing Factor
|
| 360 |
-
DesignDay, !- Cooling Design Air Flow Method
|
| 361 |
-
0, !- Cooling Design Air Flow Rate {m3/s}
|
| 362 |
-
0.000762, !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
|
| 363 |
-
0, !- Cooling Minimum Air Flow {m3/s}
|
| 364 |
-
0, !- Cooling Minimum Air Flow Fraction
|
| 365 |
-
DesignDay, !- Heating Design Air Flow Method
|
| 366 |
-
0, !- Heating Design Air Flow Rate {m3/s}
|
| 367 |
-
0.002032, !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
|
| 368 |
-
0.1415762, !- Heating Maximum Air Flow {m3/s}
|
| 369 |
-
0.3, !- Heating Maximum Air Flow Fraction
|
| 370 |
-
, !- Design Specification Zone Air Distribution Object Name
|
| 371 |
-
No; !- Account for Dedicated Outdoor Air System
|
| 372 |
-
|
| 373 |
Schedule:Constant,
|
| 374 |
Always_On, !- Name
|
| 375 |
, !- Schedule Type Limits Name
|
|
|
|
| 216 |
, !- Maximum Number of Warmup Days
|
| 217 |
; !- Minimum Number of Warmup Days
|
| 218 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 219 |
Schedule:Compact,
|
| 220 |
Thermostat Schedule, !- Name
|
| 221 |
Thermostat Schedule Type Limits, !- Schedule Type Limits Name
|
|
|
|
| 329 |
24:00, !- Time 1 {hh:mm}
|
| 330 |
26.7; !- Value Until Time 1
|
| 331 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 332 |
Schedule:Constant,
|
| 333 |
Always_On, !- Name
|
| 334 |
, !- Schedule Type Limits Name
|