Update README.md
Browse files
README.md
CHANGED
|
@@ -126,19 +126,29 @@ generated_output = tokenizer.decode(generated_ids[0], skip_special_tokens=True)
|
|
| 126 |
# Default thermal zones setting
|
| 127 |
zone_1 = """ZoneHVAC:EquipmentConnections,Thermal Zone 1,Thermal Zone 1 Equipment,Thermal Zone 1 Ideal Loads Supply Inlet,,Thermal Zone 1 Zone Air Node,Thermal Zone 1 Return Outlet;
|
| 128 |
ZoneHVAC:EquipmentList,Thermal Zone 1 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 1 Ideal Loads Air System,1,1,,;
|
| 129 |
-
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 1 Ideal Loads Air System,,Thermal Zone 1 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
|
|
|
|
|
|
| 130 |
zone_2 = """ZoneHVAC:EquipmentConnections,Thermal Zone 2,Thermal Zone 2 Equipment,Thermal Zone 2 Ideal Loads Supply Inlet,,Thermal Zone 2 Zone Air Node,Thermal Zone 2 Return Outlet;
|
| 131 |
ZoneHVAC:EquipmentList,Thermal Zone 2 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 2 Ideal Loads Air System,1,1,,;
|
| 132 |
-
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 2 Ideal Loads Air System,,Thermal Zone 2 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
|
|
|
|
|
|
| 133 |
zone_3 = """ZoneHVAC:EquipmentConnections,Thermal Zone 3,Thermal Zone 3 Equipment,Thermal Zone 3 Ideal Loads Supply Inlet,,Thermal Zone 3 Zone Air Node,Thermal Zone 3 Return Outlet;
|
| 134 |
ZoneHVAC:EquipmentList,Thermal Zone 3 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 3 Ideal Loads Air System,1,1,,;
|
| 135 |
-
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 3 Ideal Loads Air System,,Thermal Zone 3 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
|
|
|
|
|
|
| 136 |
zone_4 = """ZoneHVAC:EquipmentConnections,Thermal Zone 4,Thermal Zone 4 Equipment,Thermal Zone 4 Ideal Loads Supply Inlet,,Thermal Zone 4 Zone Air Node,Thermal Zone 4 Return Outlet;
|
| 137 |
ZoneHVAC:EquipmentList,Thermal Zone 4 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 4 Ideal Loads Air System,1,1,,;
|
| 138 |
-
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 4 Ideal Loads Air System,,Thermal Zone 4 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
|
|
|
|
|
|
| 139 |
zone_5 = """ZoneHVAC:EquipmentConnections,Thermal Zone 5,Thermal Zone 5 Equipment,Thermal Zone 5 Ideal Loads Supply Inlet,,Thermal Zone 5 Zone Air Node,Thermal Zone 5 Return Outlet;
|
| 140 |
ZoneHVAC:EquipmentList,Thermal Zone 5 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 5 Ideal Loads Air System,1,1,,;
|
| 141 |
-
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 5 Ideal Loads Air System,,Thermal Zone 5 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
|
|
|
|
|
|
| 142 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 1;", zone_1)
|
| 143 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 2;", zone_2)
|
| 144 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 3;", zone_3)
|
|
|
|
| 126 |
# Default thermal zones setting
|
| 127 |
zone_1 = """ZoneHVAC:EquipmentConnections,Thermal Zone 1,Thermal Zone 1 Equipment,Thermal Zone 1 Ideal Loads Supply Inlet,,Thermal Zone 1 Zone Air Node,Thermal Zone 1 Return Outlet;
|
| 128 |
ZoneHVAC:EquipmentList,Thermal Zone 1 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 1 Ideal Loads Air System,1,1,,;
|
| 129 |
+
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 1 Ideal Loads Air System,,Thermal Zone 1 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
| 130 |
+
ZoneControl:Thermostat,Thermal Zone 1 Thermostat,Thermal Zone 1,Thermostat Schedule,ThermostatSetpoint:DualSetpoint,Thermostat Setpoint Dual Setpoint,,,,,,,0;
|
| 131 |
+
Sizing:Zone,Thermal Zone 1,SupplyAirTemperature,14,11.11,SupplyAirTemperature,40,11.11,0.0085,0.008,Ventilation,,,DesignDay,0,0.000762,0,0,DesignDay,0,0.002032,0.1415762,0.3,,No;"""
|
| 132 |
zone_2 = """ZoneHVAC:EquipmentConnections,Thermal Zone 2,Thermal Zone 2 Equipment,Thermal Zone 2 Ideal Loads Supply Inlet,,Thermal Zone 2 Zone Air Node,Thermal Zone 2 Return Outlet;
|
| 133 |
ZoneHVAC:EquipmentList,Thermal Zone 2 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 2 Ideal Loads Air System,1,1,,;
|
| 134 |
+
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 2 Ideal Loads Air System,,Thermal Zone 2 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
| 135 |
+
ZoneControl:Thermostat,Thermal Zone 2 Thermostat,Thermal Zone 2,Thermostat Schedule,ThermostatSetpoint:DualSetpoint,Thermostat Setpoint Dual Setpoint,,,,,,,0;
|
| 136 |
+
Sizing:Zone,Thermal Zone 2,SupplyAirTemperature,14,11.11,SupplyAirTemperature,40,11.11,0.0085,0.008,Ventilation,,,DesignDay,0,0.000762,0,0,DesignDay,0,0.002032,0.1415762,0.3,,No;"""
|
| 137 |
zone_3 = """ZoneHVAC:EquipmentConnections,Thermal Zone 3,Thermal Zone 3 Equipment,Thermal Zone 3 Ideal Loads Supply Inlet,,Thermal Zone 3 Zone Air Node,Thermal Zone 3 Return Outlet;
|
| 138 |
ZoneHVAC:EquipmentList,Thermal Zone 3 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 3 Ideal Loads Air System,1,1,,;
|
| 139 |
+
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 3 Ideal Loads Air System,,Thermal Zone 3 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
| 140 |
+
ZoneControl:Thermostat,Thermal Zone 3 Thermostat,Thermal Zone 3,Thermostat Schedule,ThermostatSetpoint:DualSetpoint,Thermostat Setpoint Dual Setpoint,,,,,,,0;
|
| 141 |
+
Sizing:Zone,Thermal Zone 3,SupplyAirTemperature,14,11.11,SupplyAirTemperature,40,11.11,0.0085,0.008,Ventilation,,,DesignDay,0,0.000762,0,0,DesignDay,0,0.002032,0.1415762,0.3,,No;"""
|
| 142 |
zone_4 = """ZoneHVAC:EquipmentConnections,Thermal Zone 4,Thermal Zone 4 Equipment,Thermal Zone 4 Ideal Loads Supply Inlet,,Thermal Zone 4 Zone Air Node,Thermal Zone 4 Return Outlet;
|
| 143 |
ZoneHVAC:EquipmentList,Thermal Zone 4 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 4 Ideal Loads Air System,1,1,,;
|
| 144 |
+
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 4 Ideal Loads Air System,,Thermal Zone 4 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
| 145 |
+
ZoneControl:Thermostat,Thermal Zone 4 Thermostat,Thermal Zone 4,Thermostat Schedule,ThermostatSetpoint:DualSetpoint,Thermostat Setpoint Dual Setpoint,,,,,,,0;
|
| 146 |
+
Sizing:Zone,Thermal Zone 4,SupplyAirTemperature,14,11.11,SupplyAirTemperature,40,11.11,0.0085,0.008,Ventilation,,,DesignDay,0,0.000762,0,0,DesignDay,0,0.002032,0.1415762,0.3,,No;"""
|
| 147 |
zone_5 = """ZoneHVAC:EquipmentConnections,Thermal Zone 5,Thermal Zone 5 Equipment,Thermal Zone 5 Ideal Loads Supply Inlet,,Thermal Zone 5 Zone Air Node,Thermal Zone 5 Return Outlet;
|
| 148 |
ZoneHVAC:EquipmentList,Thermal Zone 5 Equipment,SequentialLoad,ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 5 Ideal Loads Air System,1,1,,;
|
| 149 |
+
ZoneHVAC:IdealLoadsAirSystem,Thermal Zone 5 Ideal Loads Air System,,Thermal Zone 5 Ideal Loads Supply Inlet,,,50,13,0.0156,0.0077,NoLimit,,,NoLimit,,,,,ConstantSensibleHeatRatio,0.7,None,,,None,NoEconomizer,None,0.7,0.65;
|
| 150 |
+
ZoneControl:Thermostat,Thermal Zone 5 Thermostat,Thermal Zone 5,Thermostat Schedule,ThermostatSetpoint:DualSetpoint,Thermostat Setpoint Dual Setpoint,,,,,,,0;
|
| 151 |
+
Sizing:Zone,Thermal Zone 5,SupplyAirTemperature,14,11.11,SupplyAirTemperature,40,11.11,0.0085,0.008,Ventilation,,,DesignDay,0,0.000762,0,0,DesignDay,0,0.002032,0.1415762,0.3,,No;"""
|
| 152 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 1;", zone_1)
|
| 153 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 2;", zone_2)
|
| 154 |
generated_output = generated_output.replace("Ideal Load System Setting for Thermal Zone 3;", zone_3)
|