Next-Day Air Quality (PM2.5) Forecaster for Karachi & Lahore

Course: CT-378 Machine Learning, Semester Project
Team: Khubsoorat Shklen (Muhammad Sarim Umer, Muhammad Feras Malik, Muhammad Ahmed Khan)
Institution: Department of Computer Science & Information Technology, NED University


1. Model Summary

This repository hosts the production Next-Day Air Quality Forecaster for Karachi and Lahore, Pakistan. The model predicts ground-level PM2.5 concentration 24 hours into the future ($t + 24\text{h}$) in $\mu\text{g/m}^3$ using recent air quality trends and weather features. The quantitative forecast is subsequently mapped into standard US EPA AQI health categories (Good, Moderate, Unhealthy for Sensitive Groups, Unhealthy, Very Unhealthy, Hazardous) with actionable public health advisories.

2. Model Architecture

The model is an engineered Blended Ensemble combining three complementary model paradigms:

  1. L2-Regularized Linear Model (Ridge Regression, $\alpha=10.0$): Provides stable low-variance baseline predictions.
  2. Bagged Decision Trees (Random Forest, 120 estimators, depth 12): Captures non-linear thresholds and feature splits.
  3. Gradient Boosted Decision Trees (LightGBM, 300 estimators, 45 leaves, lr=0.03): Optimizes residual corrections sequentially.
  • Preprocessing: ColumnTransformer with StandardScaler for numeric columns and OneHotEncoder for the city identifier.
  • Input Features (39 features):
    • Current PM2.5 and historical lags ($1\text{h}, 3\text{h}, 6\text{h}, 12\text{h}, 24\text{h}, 168\text{h}$)
    • Rolling aggregations ($6\text{h}, 24\text{h}, 72\text{h}$ means, $24\text{h}$ min/max/std)
    • Momentum & physical indicators ($3\text{h}$ velocity, $6\text{h}$ and $24\text{h}$ change, 2nd-derivative acceleration)
    • Meteorological variables from Open-Meteo at time $t$ (temperature, humidity, surface pressure, wind speed/direction, precipitation, cloud cover)
    • Atmospheric stagnation index: $\frac{1}{\text{wind speed}} \times \frac{\text{relative humidity}}{100}$
    • Punjab seasonal crop-burning curve and city-specific winter smog risk
    • Calendar & diurnal cycles (hour sine/cosine, weekday, month, winter flag)

3. Training & Validation Setup

  • Dataset: 24,599 hourly observations collected from 28 ground monitors (12 in Karachi, 16 in Lahore) via OpenAQ (AirGradient sensors) paired with Open-Meteo Historical Weather API.
  • Split Scheme: Strict chronological 70/15/15 train/validation/test split with an enforced 24-hour purge gap to prevent temporal label leakage.
  • Zero Future Weather Leakage: All weather inputs are observed at prediction time $t$ or preceding 24 hours (no oracle $t+24$ weather).

4. Benchmark Performance

Evaluated on the held-out chronological test set (3,678 samples, August 15 – October 31):

Metric 24-Hour Persistence Baseline Final Blended Ensemble Relative Improvement
Overall MAE $14.64,\mu\text{g/m}^3$ $13.21,\mu\text{g/m}^3$ +9.7%
Overall RMSE $27.17,\mu\text{g/m}^3$ $23.43,\mu\text{g/m}^3$ +13.8%
Overall $R^2$ $0.5765$ $0.6762$ +0.0997
EPA AQI Accuracy $69.83%$ $71.83%$ +2.0 pp

Per-City Breakdown

City Test MAE Test RMSE Test $R^2$ EPA AQI Accuracy Accuracy within $\pm 1$ Category
Karachi $6.15,\mu\text{g/m}^3$ $9.26,\mu\text{g/m}^3$ $0.7405$ $82.44%$ $99.84%$
Lahore $20.27,\mu\text{g/m}^3$ $31.82,\mu\text{g/m}^3$ $0.5735$ $61.23%$ $96.41%$

Note on Lahore: Lahore's $R^2$ exceeds the 24h persistence baseline ($0.4542$) by +0.1193 (+26% relative increase in variance explained). Severe smog spikes ($>150,\mu\text{g/m}^3$) are detected with 65.6% precision and 63.0% recall.

5. Usage in Python

import joblib
import pandas as pd
from huggingface_hub import hf_hub_download

# Download model pipeline from Hugging Face Hub
model_path = hf_hub_download(
    repo_id="MuhammadSarimUmer/next-day-pm25-forecaster",
    filename="final_pipeline.joblib"
)
pipeline = joblib.load(model_path)

# Example input DataFrame (containing all 39 feature columns)
# df = pd.DataFrame([sample_feature_dict])
# pred_pm25 = pipeline.predict(df)[0]
# print(f"Predicted PM2.5 in 24 hours: {pred_pm25:.1f} µg/m³")

6. Known Limitations

  1. Regression toward the Mean: On high-pollution spikes in Lahore ($>125.4,\mu\text{g/m}^3$), the model tends to underpredict peak values (mean bias: $-33.4,\mu\text{g/m}^3$) due to mean-squared and mean-absolute loss penalization across the year.
  2. Sensor Grade: Station observations come from low-cost AirGradient sensors aggregated at the city level, suitable for public advisory but not regulatory compliance.

Repository: GitHub
Live Space: Hugging Face Space

Downloads last month

-

Downloads are not tracked for this model. How to track
Inference Providers NEW
This model isn't deployed by any Inference Provider. 🙋 Ask for provider support

Space using MuhammadSarimUmer/next-day-pm25-forecaster 1

Evaluation results

  • Test MAE (µg/m³) on Karachi & Lahore Ground Sensors
    self-reported
    13.210
  • Test RMSE (µg/m³) on Karachi & Lahore Ground Sensors
    self-reported
    23.430
  • Test R² on Karachi & Lahore Ground Sensors
    self-reported
    0.676
  • EPA AQI Category Accuracy (%) on Karachi & Lahore Ground Sensors
    self-reported
    71.830