vera-bernhard's picture
Update model card
e82a35e verified
|
Raw History Blame Contribute Delete
3.96 kB
---
library_name: transformers
base_model: dmis-lab/biobert-v1.1
tags:
- transformers
- pytorch
- biomedical
- text-classification
- psynamic
license: apache-2.0
language:
- en
pipeline_tag: text-classification
---
# biobert-setting-20261106
Fine-tuned model from the PsyNamic project ([code](https://github.com/Ineichen-Group/PsyNamic), [webapp](https://psynamic.dcr.unibe.ch)): Setting.
This is the model deployed in the PsyNamic webapp after the revision (Nov 2026). It supersedes [STRIDE-lab/pubmedbert-setting-20250221](https://huggingface.co/STRIDE-lab/pubmedbert-setting-20250221) (tag `submission-v1`, initial submission). All current models: [PsyNamic collection](https://huggingface.co/collections/STRIDE-lab/psynamic).
## Base Model
`dmis-lab/biobert-v1.1`
## Task
**Setting** (multi-label: several labels per abstract possible)
Identifies the context in which the substance was applied (e.g., clinical, naturalistic, party).
## Labels (id2label)
| ID | Label | Definition |
|---|---|---|
| 0 | Clinical | The substance is applied in a clinical setting, e.g., a room of a clinic (this will be the large majority). |
| 1 | Naturalistic | The substance is applied in a naturalistic setting, e.g., within a traditional ayahuasca ceremony in nature. |
| 2 | Party setting | – |
| 3 | Other setting | – |
| 4 | Unknown | Select only if it is unclear from the context. E.g., select this for studies which look at memory functions from MDMA users in which the setting is not described. |
| 5 | Not applicable | E.g., for most systematic reviews, except e.g., systematic reviews which look at naturalistic settings of psychedelic substances. |
| 6 | Palliative Setting | I.e. end of life. |
## Prediction rule
Multi-label: a sigmoid is applied per label, and every label with probability **≥ 0.12** is predicted. This is the threshold used in the PsyNamic webapp. It was tuned on the validation set with a pre-specified rule: start at the threshold with maximal weighted F1, then lower it as long as weighted precision stays within 0.05 of its value there.
## Model selection
Five base models (BiomedBERT-abstract, BioBERT, BioLinkBERT, ClinicalBERT, SciBERT) were fine-tuned with identical hyperparameters. The checkpoint is the one with the lowest validation loss (early stopping), and the base model was selected on the validation set (weighted F1). The test set was used once, after selection.
## Test Performance
Held-out test set (98 abstracts), tuned threshold as in the webapp, 95% bootstrap CIs (1,000 BCa resamples).
| Metric (test) | Value [95% CI] |
|---|---|
| **Weighted F1** | **0.850 [0.762–0.906]** |
| Weighted precision | 0.820 [0.720–0.882] |
| Weighted recall | 0.891 [0.814–0.942] |
## Usage
```python
import torch
from transformers import AutoTokenizer, AutoModelForSequenceClassification
repo = "STRIDE-lab/biobert-setting-20261106"
tokenizer = AutoTokenizer.from_pretrained(repo)
model = AutoModelForSequenceClassification.from_pretrained(repo)
inputs = tokenizer("<title>. <abstract>", truncation=True, max_length=512, return_tensors="pt")
logits = model(**inputs).logits
probs = torch.sigmoid(logits)[0]
pred = [model.config.id2label[i] for i, p in enumerate(probs) if p >= 0.12]
```
## Training Parameters
```json
{
"data": "<private_dataset>",
"task": "Setting",
"model": "biobert",
"cross_val": false,
"batch_size": 8,
"learning_rate": 5e-05,
"weight_decay": 0.01,
"lr_scheduler": "linear",
"warmup_ratio": 0.1,
"epochs": 30,
"dropout": 0.1,
"early_stopping_patience": 5,
"gradient_clipping": 1.0,
"max_length": 512,
"threshold": 0.5,
"is_multilabel": true
}
```
`threshold` (0.5) is only the cut-off used to compute the validation metrics during training. It does not affect the model weights or the checkpoint choice (lowest validation loss). Predictions in the webapp and the test performance above use the tuned threshold **0.12** (see Prediction rule).