clinicalbert-data-collection-20261106

Fine-tuned model from the PsyNamic project (code, webapp): Data Collection. This is the model deployed in the PsyNamic webapp after the revision (Nov 2026). It supersedes STRIDE-lab/biobert-data-collection-20250221 (tag submission-v1, initial submission). All current models: PsyNamic collection.

Base Model

emilyalsentzer/Bio_ClinicalBERT

Task

Data Collection

Indicates whether data were collected prospectively or retrospectively.

Labels (id2label)

ID Label Definition
0 Not applicable E.g., for systematic reviews.
1 Prospective Data has been gathered prospectively (always select prospective for study protocols).
2 Retrospective Data has been collected retrospectively (case series and reports are always retrospective).
3 Unknown Data collection unknown.

Prediction rule

Single-label: softmax over the labels, the label with the highest probability (argmax) is predicted.

Model selection

Five base models (BiomedBERT-abstract, BioBERT, BioLinkBERT, ClinicalBERT, SciBERT) were fine-tuned with identical hyperparameters. The checkpoint is the one with the lowest validation loss (early stopping), and the base model was selected on the validation set (weighted F1). The test set was used once, after selection.

Test Performance

Held-out test set (96 abstracts), argmax as in the webapp, 95% bootstrap CIs (1,000 BCa resamples).

Metric (test) Value [95% CI]
Weighted F1 0.901 [0.834–0.952]
Weighted precision 0.923 [0.869–0.978]
Weighted recall 0.906 [0.833–0.948]

Usage

import torch
from transformers import AutoTokenizer, AutoModelForSequenceClassification

repo = "STRIDE-lab/clinicalbert-data-collection-20261106"
tokenizer = AutoTokenizer.from_pretrained(repo)
model = AutoModelForSequenceClassification.from_pretrained(repo)
inputs = tokenizer("<title>. <abstract>", truncation=True, max_length=512, return_tensors="pt")
logits = model(**inputs).logits
pred = model.config.id2label[int(logits.argmax(-1))]

Training Parameters

{
  "data": "<private_dataset>",
  "task": "Data Collection",
  "model": "clinicalbert",
  "cross_val": false,
  "batch_size": 8,
  "learning_rate": 5e-05,
  "weight_decay": 0.01,
  "lr_scheduler": "linear",
  "warmup_ratio": 0.1,
  "epochs": 30,
  "dropout": 0.1,
  "early_stopping_patience": 5,
  "gradient_clipping": 1.0,
  "max_length": 512,
  "threshold": 0.5,
  "is_multilabel": false
}

threshold (0.5) is only used to compute the validation metrics of multi-label tasks during training. It has no effect for this single-label model, which predicts by argmax.

Downloads last month
69
Safetensors
Model size
0.1B params
Tensor type
F32
Β·
Inference Providers NEW
This model isn't deployed by any Inference Provider. πŸ™‹ Ask for provider support

Model tree for STRIDE-lab/clinicalbert-data-collection-20261106

Finetuned
(73)
this model

Collection including STRIDE-lab/clinicalbert-data-collection-20261106