Osler-9B

Osler-9B (abhinand/Osler-9B) is a standalone, merged 8.39B Apache-2.0 general medical & clinical decision model ("System One" single-pass). Given any clinical state (an EHR note, discharge summary, clinical trial record, FDA drug label, or medical question) and typed questions (choice over 2–255 options, noul yes/no, or score over 2–10 ordered levels), it returns calibrated probabilities for every offered option in one prefill pass — no text generation and no external custom library required.

  • #1 overall across 12 evaluated models on 5-set macro (0.7801 vs. 0.7600 for pplx-27B), #1 on fresh post-cutoff decisions (0.9008), #1 best calibrated on the 7-dataset External Panel (ECE 0.0229), and top-2 / best ≤10B on Medical Exams (0.7322) & External Panel (0.5927) — while beating pplx-27B by +9.6 pts on EHR & clinical documentation (0.8375 vs. 0.7411) at 2.7× lower latency (33.7 ms) and 3.1× less VRAM (17.3 GB).
  • Standalone merged weights: Full BF16 Qwen3_5Model safetensors shards (attention LoRA r=32 merged) + FP32 [255, 4096] option-code readout + bundled d3_runtime & d3_server.py.
  • Non-generative by architecture: Carries no lm_head (Qwen3_5Model + 255-way option-code readout); cannot generate free text.
  • Dev-only per-type calibration built in: choice: 1.5274, noul: 2.3185, score: 1.7035 (applied automatically by AutoModel.from_pretrained(..., trust_remote_code=True)).
  • Base model: vllm-sr/d3-flash (revision 67e03e1bc157961c582ee7c6a35d9b15fada3dec, Apache-2.0, built on Qwen/Qwen3.5-9B).
  • Links: Project Page · Live Leaderboard Space · MedDecide-Bench · GitHub · Clinical Examples · Osler-4B (9.6 GB) · HF Collection

Key Capabilities & Pareto Frontier

1. Both sizes on the Efficiency–Accuracy Pareto frontier: On Size / Latency / VRAM vs. 5-Set Macro, Osler-4B (4.55B, 9.6 GB, 0.7530) and Osler-9B (8.39B, 17.3 GB, 0.7801) define the frontier — Osler-9B strictly outperforms pplx-27B (26.09B, 52.9 GB, 0.7600) at 3.1× less VRAM and 2.7× lower latency.

2. General medical & independent external proof (not just EHR): Even with zero EHR sets, Osler-9B sits on the Size vs. General Medical QA Pareto frontier (0.7419, best ≤10B), ranks #1 on Fresh Tier-2 (0.9008), #1 of 11 on External Panel calibration (ECE 0.0229, 5× better than pplx-27B), and #1 / #2 on independent MedNLI (0.8917 9B / 0.8910 4B — both beating pplx-27B 0.8748).

3. EHR mastery, 2–255 options & calibrated abstention: Both models beat pplx-27B on EHR & Clinical Docs (+9.6 pts 9B, +8.6 pts 4B), natively score 2–255 options (no 10-option cap), and reach 98.2% accuracy at 80% coverage (99.8% at 50%) on Clinical Docs via a single confidence threshold.


Quickstart — Hugging Face transformers (Zero Extra Libraries)

pip install "transformers>=5.0.0" torch safetensors accelerate pillow
# Optional fast linear-attention kernels on CUDA:
pip install flash-linear-attention
from transformers import AutoModel

model = AutoModel.from_pretrained("abhinand/Osler-9B", trust_remote_code=True)

result = model.system_one(
    state=(
        "68-year-old male admitted with fever 38.9C, HR 118, RR 26, BP 84/52 mmHg, "
        "lactate 4.2 mmol/L, and blood cultures growing E. coli. Started on IV norepinephrine "
        "and piperacillin-tazobactam in the ICU."
    ),
    questions={
        "sepsis_supported": {
            "type": "noul",
            "instructions": "Does the clinical documentation support a diagnosis of septic shock?",
        },
        "acuity": {
            "type": "choice",
            "instructions": "Select the highest-acuity clinical syndrome documented.",
            "criteria": {
                "septic_shock": "Sepsis with vasopressor-dependent hypotension and hyperlactatemia",
                "uncomplicated_uti": "Lower urinary tract infection without systemic involvement",
                "stable_angina": "Exertional chest pain relieved by rest",
            },
        },
        "documentation_strength": {
            "type": "score",
            "instructions": "Rate the strength of clinical indicator evidence for severe sepsis.",
            "criteria": ["none", "weak", "moderate", "strong", "definitive"],
        },
    },
)

print(result["answers"])
Example Clinical Decisions (click to expand 5 diverse real-world vignettes)

Measured directly on this merged checkpoint (one question per call, built-in dev calibration). See more examples on GitHub.

Clinical Scenario (condensed state) Question (type) Osler-9B Output
Negation / Ruled-out PE: Substernal burning post-flight; CTA chest showed NO PE, trop <6, resolved with lidocaine + pantoprazole. Confirm PE? (noul) / Final dx (choice: pe, nstemi, gerd, pneumothorax) p(yes) = 0.043 / gerd (0.993)
Messy EHR distractor: Childhood asthma + mild wheeze ("cardiac asthma"), failed albuterol; EF 25%, JVP 14, BNP 2,650, Kerley B lines. Primary driver of dyspnea? (choice: asthma, hfref_exacerbation, copd, pneumonia) / IV diuretic indicated? (noul) hfref_exacerbation (0.997) / p(yes) = 0.956
Metabolic differential: T2DM on metformin, gastroenteritis, Cr 4.1 (base 1.5), glucose 114, lactate 10.2, ketones negative. Metabolic emergency? (choice: dka, hhs, mala, salicylate) / Supports DKA? (noul) mala (0.985) / p(yes) = 0.086
Abstention / Missing evidence: 1.8 cm spiculated RUL lung nodule on screening CT; PET-CT and biopsy pending, no pathology yet. Confirmed TNM stage? (choice: stage_i, stage_iii, stage_iv, insufficient_info) insufficient_info (0.968)
Trial eligibility exclusion: Meets HFrEF inclusion (NYHA III, LVEF 30% on GDMT), but eGFR 28 (<30 exclusion) & active FOLFOX chemo. Eligible to enroll? (noul) p(yes) = 0.019

Serving with vLLM Semantic Router & Standalone HTTP Server

Note on standard vllm serve: Osler-9B is a noncausal full-attention single-pass decision model (Qwen3_5Model + [255, 4096] option-code readout, no lm_head). Standard autoregressive vllm serve expects a causal ForCausalLM architecture and does not serve noncausal System-One readout heads. Use vLLM Semantic Router Engine mode (vllm-sr) or the bundled d3_server.py HTTP server below.

Option A — vLLM Semantic Router (vllm-sr, recommended for production throughput)

Osler-9B uses the native Decision 3.0 (d3-code-readout-v1) package layout supported directly by vLLM Semantic Router:

curl -fsSL https://vllm-sr.ai/install.sh | bash -s -- --channel dev --no-launch
export PATH="$HOME/.local/bin:$PATH"
vllm-sr serve -e abhinand/Osler-9B

Query the live endpoint:

curl -s http://localhost:8899/v1/systemone   -H 'content-type: application/json'   -d '{
    "model": "abhinand/Osler-9B",
    "state": "Serum creatinine rose from 0.9 mg/dL to 2.4 mg/dL over 36 hours with oliguria.",
    "questions": {
      "aki": {"type": "noul", "instructions": "Do the documented lab values meet KDIGO AKI criteria?"}
    }
  }'

(Note: vllm-sr uses the scalar temperature in decision_config.json (1.5274, exact for choice); for exact per-qtype noul/score temperatures over HTTP, use Option B below.)

Option B — Bundled Standalone HTTP Server (d3_server.py)

huggingface-cli download abhinand/Osler-9B --local-dir ./Osler-9B
python ./Osler-9B/d3_server.py --model ./Osler-9B --host 0.0.0.0 --port 8080

Headline Benchmark Results (12-Model Unified Evaluation, 9 Frozen Sets)

Model Params panel (4,353) knowledge (5,456) confirm_general (5,988) mr_verdict (13,103) mimic_suite (4,253) 5-Set Macro Batch-1 p50 Peak VRAM
Osler-9B 8.39B 0.5927 0.7322 0.9008 0.9016 0.7733 0.7801 33.71 ms 17.32 GB
pplx-27B (27B ceiling) 26.09B 0.6510 0.7823 0.8843 0.8093 0.6729 0.7600 90.96 ms 52.92 GB
Osler-4B 4.55B 0.5502 0.6728 0.8883 0.8941 0.7597 0.7530 26.54 ms 9.60 GB
d3-flash (9B base) 8.39B 0.5899 0.7335 0.8774 0.7351 0.6301 0.7132 33.80 ms 17.32 GB
pplx-flash (4B base) 4.54B 0.5615 0.6835 0.8889 0.7466 0.6240 0.7009 25.51 ms 9.58 GB
Clef-Flash 9.00B 0.5711 0.6864 0.8933 0.6831 0.6306 0.6929 — —
MedDecider-9B 9.00B 0.5603 0.6997 0.8825 0.6653 0.6189 0.6853 — —
MedDecider-4B 4.00B 0.5436 0.6703 0.8820 0.6681 0.6019 0.6732 — —
  • Global 2-axis Pareto front (General Medical QA Avg vs. EHR & Clinical Docs Avg): Osler-9B (0.7419, 0.8375) and pplx-27B (0.7725, 0.7411). Osler-9B is the only ≤10B model on the front, outperforms pplx-27B by +9.6 pts on EHR and clinical documentation tasks (mr_verdict +9.23, mimic_suite +10.04) while running 2.7× faster in 3.1× less VRAM, and strictly dominates every comparable ≤10B model on all five headline sets.
  • Calibration: panel ECE 0.0229 (raw 0.1085, best of all 12 models; Brier 0.5223), mr_verdict ECE 0.0220 (Brier 0.1421), knowledge ECE 0.0441.
  • Selective abstention: At 80% coverage, Osler-9B reaches 98.22% accuracy on mr_verdict (99.77% at 50%) and 82.81% on mimic_suite (90.31% at 50%).
  • Additional sets: mednli_test 0.8917 (#1), pairs_test 0.9620 (#1), mimic_heldout 0.7000.

Privacy & MIMIC PHI / Memorisation Audit (Local-Only)

  • MIMIC-IV 3.1 / MIMIC-IV-Note 2.2 / MIMIC-IV-ED were processed strictly on local hardware (never sent to any hosted API), split by patient (anchor_year_group ≥ 2014 held out). Zero training data or MIMIC text is included in this repository.
  • Visited-member membership inference (2,000 MIMIC rows visited during training vs. 2,000 late-anchor non-members with 0 hash overlap): AUC 0.5876 [0.5703, 0.6051] vs. zero-shot d3-flash control 0.5408 → Δ +0.0468 (clears pre-registered ≤ 0.05 rule). Y10 historical compatibility AUC: 0.5018.
  • Verbatim extraction: Structurally not applicable — Osler-9B carries no lm_head and cannot generate text.

Honest Limitations

  1. OOD QA parity vs. base / ceiling vs. 27B: Ties (does not beat) d3-flash on panel (+0.0028 [-0.0069, +0.0129]) and knowledge (-0.0013 [-0.0090, +0.0062]), and trails pplx-27B on hard multi-step medical QA (MedXpertQA, MMLU-Pro Health).
  2. Held-out template failure (READOUT_FAIL): On mr_heldout_test / synthea_indicator_evidence_v1 (n=514, excluded from training), Osler-9B falls below chance (0.356, READOUT_FAIL) while its base passes (0.459).
  3. Fresh-distribution calibration shift: Dev-fitted temperatures leave the model under-confident on fresh confirm_general (mean confidence 0.814 vs. accuracy 0.901, ECE 0.090). Recalibrate on a small target-domain dev split when deploying under strong distribution shift.
  4. Not for unsupervised clinical decisions: Research model outputs must be reviewed by qualified clinicians.
Downloads last month
53
Safetensors
Model size
8B params
Tensor type
BF16
·
Inference Providers NEW
This model isn't deployed by any Inference Provider. 🙋 Ask for provider support

Model tree for abhinand/Osler-9B

Finetuned
Qwen/Qwen3.5-9B
Finetuned
(1,596)
this model

Space using abhinand/Osler-9B 1

Collection including abhinand/Osler-9B