Title: Towards Resource-Efficient Streaming of Large-Scale Medical Image Datasets for Deep Learning

URL Source: https://arxiv.org/html/2307.00438

Published Time: Tue, 03 Jun 2025 01:11:46 GMT

Markdown Content: \jmlryear

2025 \jmlrworkshop Full Paper – MIDL 2025 \jmlrvolume– nnn \midlauthor\Name Pranav Kulkarni\nametag 1,2\orcid 0000-0001-5291-2202 \Email pkulkarni@som.umaryland.edu

\Name Adway Kanhere\nametag 1,2\orcid 0000-0001-5295-2634 \Email akanhere@som.umaryland.edu

\Name Eliot L. Siegel\nametag 1\Email esiegel@som.umaryland.edu

\Name Paul H. Yi\nametag 3\orcid 0000-0001-9433-8093 \Email paul.yi@stjude.org

\Name Vishwa S. Parekh\nametag 4,5\orcid 0000-0002-6306-0305\Email vishwa.s.parekh@uth.tmc.edu

\addr 1 University of Maryland School of Medicine, Baltimore, MD

\addr 2 University of Maryland Institute for Health Computing, North Bethesda, MD

\addr 3 St. Jude Children’s Research Hospital, Memphis, TN

\addr 4 UTHealth Houston, Houston, TX

\addr 5 Johns Hopkins University School of Medicine, Baltimore, MD

Abstract

Large-scale medical imaging datasets have accelerated deep learning (DL) for medical image analysis. However, the large scale of these datasets poses a challenge for researchers, resulting in increased storage and bandwidth requirements for hosting and accessing them. Since different researchers have different use cases and require different resolutions or formats for DL, it is neither feasible to anticipate every researcher’s needs nor practical to store data in multiple resolutions and formats. To that end, we propose the Medical Image Streaming Toolkit (MIST), a format-agnostic database that enables streaming of medical images at different resolutions and formats from a single high-resolution copy. We evaluated MIST across eight popular, large-scale medical imaging datasets spanning different body parts, modalities, and formats. Our results showed that our framework reduced the storage and bandwidth requirements for hosting and downloading datasets without impacting image quality. We demonstrate that MIST addresses the challenges posed by large-scale medical imaging datasets by building a data-efficient and format-agnostic database to meet the diverse needs of researchers and reduce barriers to DL research in medical imaging.

keywords:

Imaging Databases, Compression, Progressive Streaming, Data-Efficiency

††editors: Accepted for publication at MIDL 2025 1 Introduction

The curation of large-scale, publicly accessible medical imaging datasets has accelerated the development of deep learning (DL) models for medical image analysis [Hosny et al.(2018)Hosny, Parmar, Quackenbush, Schwartz, and Aerts]. However, the large scale of medical imaging datasets poses a significant challenge for researchers both hosting or accessing them [Jia et al.(2023)Jia, Chen, Xu, Kheir, Hu, Xiao, Peng, Hu, Chen, and Shi, Li et al.(2023)Li, Zhu, Hua, Feng, Bennamoun, Li, Lu, Song, Shen, Xu, et al., Magudia et al.(2021)Magudia, Bridge, Andriole, and Rosenthal]. For researchers hosting these datasets, the growing collection of curated datasets and increasing demand for access result in greater costs for managing storage and networking infrastructures [Doo et al.(2024)Doo, Kulkarni, Siegel, Toland, Yi, Carlos, and Parekh]. On the other hand, researchers accessing the datasets require sufficient compute and storage resources to download and process hundreds of thousands of high-resolution medical images to be “DL-ready”, especially as datasets continue to grow in scale and resolution [Jia et al.(2023)Jia, Chen, Xu, Kheir, Hu, Xiao, Peng, Hu, Chen, and Shi, Kiryati and Landau(2021)].

Accessing and utilizing large-scale medical imaging datasets for DL research presents several challenges, particularly in terms of data storage, bandwidth limitations, and preprocessing requirements. For instance, training a DL model for early-stage lung cancer detection using the NLST dataset [Team(2011)] would require downloading over 11 TB of CT scans, which presents substantial storage challenges for many research environments. Furthermore, limited bandwidth can result in download times spanning several days, creating significant logistical bottlenecks. Beyond storage and bandwidth constraints, researchers often require data in different formats depending on their specific tasks. For example, 3D segmentation models necessitate preprocessing raw DICOM series into NIfTI format [Li et al.(2016)Li, Morgan, Ashburner, Smith, and Rorden], while CNN-based classification models may require lower-resolution inputs, such as 224×224 images. Unfortunately, this inefficiency scales with the number of researchers accessing the dataset. Given the diversity of research needs, it is neither feasible to anticipate all possible data configurations nor practical for each researcher to store, preprocess, and manage such large-scale datasets independently. These inefficiencies highlight the need for scalable, adaptive data access solutions that can accommodate varying research requirements while minimizing redundant computational and storage overhead.

Image 1: Refer to caption

Figure 1: An overview of MIST. Suppose a researcher uploads a high-resolution DICOM CT dataset to MIST. It is ingested and stored in a format-agnostic representation, where the pixel data is progressively encoded and separated from its associated metadata. This allows another researcher to access the dataset at a lower resolution in NIfTI format without data duplication.

To that end, we propose the Medical Image Streaming Toolkit (MIST), a format-agnostic imaging database that enables streaming of medical images at different resolutions and formats from a single high-resolution copy (\figureref fig:mist_overview). Our goal is to address the challenges posed by large-scale medical imaging datasets by building a data-efficient and format-agnostic database to meet the diverse needs of researchers in the medical imaging with DL community. The purpose of this study is to evaluate MIST for reducing the storage and bandwidth requirements for hosting and downloading eight large-scale medical imaging datasets spanning different body parts, modalities, and formats, without impacting image quality.

2 Background

One core challenge is the lack of interoperability of DICOM with popular DL frameworks (e.g., PyTorch) due to its complex multi-file structure and varying metadata tags, necessitating extensive domain expertise to preprocess DICOM series prior to training DL models [Galbusera and Cina(2024), Botnari et al.(2024)Botnari, Kadar, and Patrascu]. As a result, “DL-ready” formats (e.g., NIfTI) that are easier to use with DL frameworks have become popular among researchers. However, datasets curated as part of clinical studies with applications beyond DL are often released as DICOM databases, due to the widespread use of DICOM in clinical settings and its rich, clinically relevant metadata. The difference between formats, based on their clinical relevance and ease of use, has created a distinct format hierarchy. As a result, some collections, such as UPENN-GBM [Bakas et al.(2022)Bakas, Sako, Akbari, Bilello, Sotiras, Shukla, Rudie, Santamaría, Kazerooni, Pati, et al.], have released both DICOM and NIfTI versions of the dataset to meet the diverse needs of researchers using them. However, this results in data duplication by hosting the same dataset in multiple different formats, requiring additional storage to do so [Jiménez-Sánchez et al.(2024)Jiménez-Sánchez, Avlona, Juodelyte, Sourget, Vang-Larsen, Rogers, Zajac, and Cheplygina].

Another challenge is that many researchers may not need high-resolution medical images for developing DL models, as images are often downsampled to lower resolutions to reduce computational costs and potentially improve generalizability to unseen data [Sabottke and Spieler(2020)]. Consider MIMIC-CXR, a dataset containing 4.7 TB of chest x-rays (CXRs) with mean resolution 2500×3056 2500 3056 2500\times 3056 2500 × 3056[Johnson et al.(2019)Johnson, Pollard, Berkowitz, Greenbaum, Lungren, Deng, Mark, and Horng]. If a researcher wanted to use this dataset for training a CNN-based classifier, they would have to downsample the CXRs by more than 100 times to 224×224 224 224 224\times 224 224 × 224. This approach is highly inefficient because not only does this necessitate downloading and storing the full 4.7 TB dataset, but also requires considerable computational resources to downsample the CXRs.

In our prior work, we explored solutions to both challenges using progressive encoding in order to accelerate DL inference in clinical deployment, where latency is critical [Kulkarni et al.(2024)Kulkarni, Kanhere, Siegel, Yi, and Parekh]. Here, we primarily focus on building a flexible and scalable framework for hosting and sharing medical imaging datasets in research settings, with a focus on reducing data storage and transmission. Our approach is not intended for real-time DL applications, but rather for efficient data access across diverse research settings, where datasets are typically downloaded before being used for DL tasks.

3 Methods

3.1 Medical Image Streaming Toolkit

MIST is a format-agnostic database for hosting large-scale medical imaging datasets for developing DL models. Our framework allows a researcher to stream medical images at different resolutions and formats from a single high-resolution copy. Compared to existing solutions, MIST differs in three key aspects (\figureref fig:features):

Image 2: Refer to caption

Figure 2: (a) An illustration of MIST’s format hierarchy, where medical images are always “converted down” to other formats. (b) Medical images are compressed by progressively encoding pixel data into a bytestream using HTJ2K. (c) HTJ2K allows sub-resolution images to be accessed by decoding a partial bytestream.

Format Hierarchy: At the core of MIST is its format-agnostic design. We ingested and stored medical images in a format-agnostic representation, separating the pixel data from associated metadata (\figureref fig:mist_overview). Similar approaches have been used by AWS HealthImaging 1 1 1https://aws.amazon.com/healthimaging and the NCI Imaging Data Commons [Fedorov et al.(2021)Fedorov, Longabaugh, Pot, Clunie, Pieper, Aerts, Homeyer, Lewis, Akbarzadeh, Bontempi, et al.] for hosting medical image datasets in DICOM. Our method differs by allowing medical images in DICOM, NIfTI, or other non-medical imaging formats (e.g., JPEG, PNG) to be ingested and stored in the same format-agnostic representation.

The format-agnostic representation allows medical images to be “converted down” into other formats using the pixel data and associated metadata when streaming to researchers. To achieve this, we followed a strict format hierarchy, based on the availability of metadata, to govern how a medical image in one format is streaming in a different format (\figureref fig:featuresa). Specifically, a DICOM series can be streamed in DICOM, NIfTI, or other non-medical imaging formats, whereas a NIfTI series can only be streamed in NIfTI or other non-medical imaging formats. This limitation is because NIfTI lacks the metadata to “convert up” to DICOM, while DICOM can “convert down” to NIfTI. Similarly, non-medical imaging formats can only be streamed in other non-medical imaging formats.

When a medical image is encoded by MIST, we extracted and stored its associated metadata tags in a separate JSON file. Format conversion is handled by mapping the relevant metadata tags from the source format to equivalent tags in the target format (e.g., pixel spacing when converting from DICOM to NIfTI). This enables metadata to be preserved when converting to a different format, even when the target format is a non-medical imaging one (e.g., PNG).

Medical Image Compression: Medical image compression is used to reduce the file size of medical images, thereby requiring less resources to store and transmit large-scale medical image datasets [Koff and Shulman(2006)]. It works by encoding pixel data into a bytestream that can be decoded to reconstruct the original pixel data. We used the High-Throughput JPEG 2000 (HTJ2K) codec to encode pixel data (\figureref fig:featuresb). HTJ2K is a progressive encoding format that encodes pixel data as a series of lossy decompositions, with each subsequent one having a higher resolution [Taubman et al.(2019)Taubman, Naman, Mathew, Smith, and Watanabe, Taubman et al.(2020)Taubman, Naman, Mathew, Smith, Watanabe, and Lemieux]. When fully decoded, the pixel data is reconstructed without any data loss.

n=⌊log 2⁡min⁡(M,N)α⌋𝑛 subscript 2 𝑀 𝑁 𝛼 n=\left\lfloor\log_{2}{\frac{\min(M,N)}{\alpha}}\right\rfloor italic_n = ⌊ roman_log start_POSTSUBSCRIPT 2 end_POSTSUBSCRIPT divide start_ARG roman_min ( italic_M , italic_N ) end_ARG start_ARG italic_α end_ARG ⌋(1)

where M×N 𝑀 𝑁 M\times N italic_M × italic_N was the pixel data resolution and α=64 𝛼 64\alpha=64 italic_α = 64 was an arbitrarily set lower bound such that the first decomposition will not reconstruct an image smaller than 64×64 64 64 64\times 64 64 × 64. For a DICOM series and other non-medical imaging formats (e.g., JPEG, PNG), each image (e.g., slice in a volume) was encoded and stored separately. On the other hand, NIfTI stores the entire volume in a single file. To maintain consistency, we encoded and stored each slice of the NIfTI volume separately. We computed rescaling intercept and slope before encoding the pixel data because existing HTJ2K implementations support up to uint16 pixel data.

Access to Sub-Resolution Images: An advantage of progressive encoding is the ability to access sub-resolution images from partial bytestreams of a single high-resolution copy [Foos et al.(2000)Foos, Muka, Slone, Erickson, Flynn, Clunie, Hildebrand, Kohm, and Young, Noumeir and Pambrun(2011)]. Pixel data encoded using HTJ2K with n 𝑛 n italic_n decompositions levels contains n+1 𝑛 1 n+1 italic_n + 1 decompositions, where i 𝑖 i italic_i th decomposition has a resolution that is 1/2 n+1−i 1 superscript 2 𝑛 1 𝑖 1/2^{n+1-i}1 / 2 start_POSTSUPERSCRIPT italic_n + 1 - italic_i end_POSTSUPERSCRIPT of the original resolution (\figureref fig:featuresc). For example, an abdominal CT scan of resolution 512×512 512 512 512\times 512 512 × 512, encoded with n=3 𝑛 3 n=3 italic_n = 3 decomposition levels, can be decoded at sub-resolutions 64×64 64 64 64\times 64 64 × 64, 128×128 128 128 128\times 128 128 × 128, 256×256 256 256 256\times 256 256 × 256, and 512×512 512 512 512\times 512 512 × 512.

If the pixel data is encoded with tile-part divisions by resolution and the bytes required to reconstruct the i 𝑖 i italic_i th decomposition are available, the image can be decoded at decomposition level i−1 𝑖 1 i-1 italic_i - 1 and all previous levels without needing the complete bytestream [Kulkarni et al.(2024)Kulkarni, Kanhere, Siegel, Yi, and Parekh]. This allows researchers to download sub-resolution images using a partial bytestream. For example, a CXR with resolution 1024×1024 1024 1024 1024\times 1024 1024 × 1024 can be streamed at resolution 256×256 256 256 256\times 256 256 × 256 using the first 35 KB of the complete 448 KB bytestream.

To achieve this, we created a new entry to each medical image’s metadata that mapped decompositions to the location of tile-part markers in the bytestream. The tile-part markers define the extent of the bytestream required to decode a specific decomposition. They were identified by the start of tile-part marker (bytes 0xFF90) and end of codestream marker (bytes 0xFFD9) [Boliek et al.(2000)Boliek, Christopoulos, and Majani]. Once the pixel data is decoded at a sub-resolution, the metadata for the affine transformation matrix and voxel size is rescaled to ensure accurate transformation to world coordinates.

Table 1: Summary of datasets.

3.2 Experiments

In this study, we evaluated MIST for reducing the storage and bandwidth requirements for hosting and downloading using eight popular, large-scale medical imaging datasets for developing DL models, spanning different body parts, modalities, and formats (Table 1). Detailed descriptions of each dataset is provided in Appendix A. Our code is available at: https://github.com/BioIntelligence-Lab/MIST.

We encoded every medical image in a dataset using HTJ2K and stored them in the format-agnostic representation. Any series that failed to encode was excluded from our analysis. A series may fail due to a lack of pixel data (e.g., SEG DICOM files) or unsupported pixel data (e.g., exceeding 16-bit depth, floating point data). Then, we measured the amount of data stored and transmitted by hosts. We also measured the amount of data transmitted across all decompositions. Finally, we evaluated image quality by comparing all decompositions with the pixel data using the structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR). These quantitative metrics were measured by downsampling the pixel data to the sub-resolution (using bilinear interpolation) and rescaling pixel values to range 0-1 using scikit-image. The SSIM between pixel data X 𝑋 X italic_X and sub-resolution image Y 𝑌 Y italic_Y across windows x 𝑥 x italic_x and y 𝑦 y italic_y is defined as [Wang et al.(2004)Wang, Bovik, Sheikh, and Simoncelli]:

\text⁢S⁢S⁢I⁢M⁢(x,y)=(2⁢μ x⁢μ y+k 1 2)⁢(2⁢σ x⁢y+k 2 2)(μ x 2+μ y 2+k⁢1 2)⁢(σ x 2+σ y 2+k 2 2)\text 𝑆 𝑆 𝐼 𝑀 𝑥 𝑦 2 subscript 𝜇 𝑥 subscript 𝜇 𝑦 superscript subscript 𝑘 1 2 2 subscript 𝜎 𝑥 𝑦 superscript subscript 𝑘 2 2 superscript subscript 𝜇 𝑥 2 superscript subscript 𝜇 𝑦 2 𝑘 superscript 1 2 superscript subscript 𝜎 𝑥 2 superscript subscript 𝜎 𝑦 2 superscript subscript 𝑘 2 2\text{SSIM}(x,y)=\frac{(2\mu_{x}\mu_{y}+k_{1}^{2})(2\sigma_{xy}+k_{2}^{2})}{(% \mu_{x}^{2}+\mu_{y}^{2}+k1^{2})(\sigma_{x}^{2}+\sigma_{y}^{2}+k_{2}^{2})}italic_S italic_S italic_I italic_M ( italic_x , italic_y ) = divide start_ARG ( 2 italic_μ start_POSTSUBSCRIPT italic_x end_POSTSUBSCRIPT italic_μ start_POSTSUBSCRIPT italic_y end_POSTSUBSCRIPT + italic_k start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) ( 2 italic_σ start_POSTSUBSCRIPT italic_x italic_y end_POSTSUBSCRIPT + italic_k start_POSTSUBSCRIPT 2 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) end_ARG start_ARG ( italic_μ start_POSTSUBSCRIPT italic_x end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT + italic_μ start_POSTSUBSCRIPT italic_y end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT + italic_k 1 start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) ( italic_σ start_POSTSUBSCRIPT italic_x end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT + italic_σ start_POSTSUBSCRIPT italic_y end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT + italic_k start_POSTSUBSCRIPT 2 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) end_ARG(2)

where (μ x,σ x 2)subscript 𝜇 𝑥 superscript subscript 𝜎 𝑥 2(\mu_{x},\sigma_{x}^{2})( italic_μ start_POSTSUBSCRIPT italic_x end_POSTSUBSCRIPT , italic_σ start_POSTSUBSCRIPT italic_x end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) and (μ y,σ y 2)subscript 𝜇 𝑦 superscript subscript 𝜎 𝑦 2(\mu_{y},\sigma_{y}^{2})( italic_μ start_POSTSUBSCRIPT italic_y end_POSTSUBSCRIPT , italic_σ start_POSTSUBSCRIPT italic_y end_POSTSUBSCRIPT start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT ) are statistics of pixel values in windows x 𝑥 x italic_x and y 𝑦 y italic_y respectively, σ x⁢y subscript 𝜎 𝑥 𝑦\sigma_{xy}italic_σ start_POSTSUBSCRIPT italic_x italic_y end_POSTSUBSCRIPT is covariance of pixel values in windows x 𝑥 x italic_x and y 𝑦 y italic_y, k 1=0.01 subscript 𝑘 1 0.01 k_{1}=0.01 italic_k start_POSTSUBSCRIPT 1 end_POSTSUBSCRIPT = 0.01, and k 2=0.03 subscript 𝑘 2 0.03 k_{2}=0.03 italic_k start_POSTSUBSCRIPT 2 end_POSTSUBSCRIPT = 0.03. The PSNR between pixel data X 𝑋 X italic_X and sub-resolution image Y 𝑌 Y italic_Y of fixed resolution M×N 𝑀 𝑁 M\times N italic_M × italic_N is defined as:

\text⁢P⁢S⁢N⁢R⁢(X,Y)=10⁢log 10⁡(M⁢N∑m=1 M∑n=1 N(X m,n−Y m,n)2)\text 𝑃 𝑆 𝑁 𝑅 𝑋 𝑌 10 subscript 10 𝑀 𝑁 superscript subscript 𝑚 1 𝑀 superscript subscript 𝑛 1 𝑁 superscript subscript 𝑋 𝑚 𝑛 subscript 𝑌 𝑚 𝑛 2\text{PSNR}(X,Y)=10\log_{10}\left(\frac{MN}{\sum_{m=1}^{M}\sum_{n=1}^{N}(X_{m,% n}-Y_{m,n})^{2}}\right)italic_P italic_S italic_N italic_R ( italic_X , italic_Y ) = 10 roman_log start_POSTSUBSCRIPT 10 end_POSTSUBSCRIPT ( divide start_ARG italic_M italic_N end_ARG start_ARG ∑ start_POSTSUBSCRIPT italic_m = 1 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT italic_M end_POSTSUPERSCRIPT ∑ start_POSTSUBSCRIPT italic_n = 1 end_POSTSUBSCRIPT start_POSTSUPERSCRIPT italic_N end_POSTSUPERSCRIPT ( italic_X start_POSTSUBSCRIPT italic_m , italic_n end_POSTSUBSCRIPT - italic_Y start_POSTSUBSCRIPT italic_m , italic_n end_POSTSUBSCRIPT ) start_POSTSUPERSCRIPT 2 end_POSTSUPERSCRIPT end_ARG )(3)

where X m,n subscript 𝑋 𝑚 𝑛 X_{m,n}italic_X start_POSTSUBSCRIPT italic_m , italic_n end_POSTSUBSCRIPT and Y m,n subscript 𝑌 𝑚 𝑛 Y_{m,n}italic_Y start_POSTSUBSCRIPT italic_m , italic_n end_POSTSUBSCRIPT are pixel values of X 𝑋 X italic_X and Y 𝑌 Y italic_Y at index (m,n)𝑚 𝑛(m,n)( italic_m , italic_n ) respectively. If X 𝑋 X italic_X and Y 𝑌 Y italic_Y are equal (in the case of lossless reconstruction), then PSNR is infinity. As a result, the mean PSNR for a decomposition only considers the non-infinite PSNR values.

4 Results

Image 3: Refer to caption

Figure 3: (a) Decrease in data storage due to medical image compression. (b) Decrease in data transmission due to sub-resolution image access. Image quality measured using (c) mean SSIM and (d) mean PSNR values across all decompositions, stratified by the maximum decomposition for an image.

Medical Image Compression: We observed that MIST successfully encoded all eight datasets, with the exception of N=28 𝑁 28 N=28 italic_N = 28 (2.92%percent 2.92 2.92%2.92 %) from AMOS, N=7 𝑁 7 N=7 italic_N = 7 (0.26%percent 0.26 0.26%0.26 %) series from TCGA-KIRC, and N=20 𝑁 20 N=20 italic_N = 20 (1.07%percent 1.07 1.07%1.07 %) series from TCGA-BRCA. Excluding these series from our analysis, our method reduced the total amount of data stored and transmitted by hosts from 536.68 GB to 234.77 GB, a decrease of 56.22%percent 56.22 56.22%56.22 % (\figureref fig:resultsa). We observed that TCGA-BRCA had the greatest decrease, from 81.30 GB to 23.13 GB (71.55%percent 71.55 71.55%71.55 %), while NIH-ChestX-ray14 had the least decrease, from 41.96 GB to 40.29 GB (4%percent 4 4%4 %). On average, MIST reduced data storage by 49.79±23.27%plus-or-minus 49.79 percent 23.27 49.79\pm 23.27%49.79 ± 23.27 %. Detailed results are provided in \tableref tab:encoding_summary.

Access to Sub-Resolution Images: We observed that downloading datasets at sub-resolutions led to a further decrease in the total amount of data transmitted (\figureref fig:resultsb). At the smallest sub-resolution (i.e., decomposition level 1), MIST reduced total data transmission to 22.59 GB (95.79%percent 95.79 95.79%95.79 %), ranging from 98.93%percent 98.93 98.93%98.93 % for NIH-ChestX-ray14 to 90.36%percent 90.36 90.36%90.36 % for UPENN-GBM, with an average reduction of 96.10±3.20%plus-or-minus 96.10 percent 3.20 96.10\pm 3.20%96.10 ± 3.20 %. At the largest sub-resolution (varies across datasets; see \tableref tab:encoding_summary), our method reduced total data transmission to 189.76 GB (64.62%percent 64.62 64.62%64.62 %), ranging from 89.60%percent 89.60 89.60%89.60 % for NSCLC-Radiomics to 30.41%percent 30.41 30.41%30.41 % for AMOS, with an average reduction of 66.04±17.63%plus-or-minus 66.04 percent 17.63 66.04\pm 17.63%66.04 ± 17.63 %. Detailed results are provided in Appendix B.

Evaluation of Image Quality: We observed that MIST did not impact the image quality of all eight datasets encoded in our study, with a mean SSIM of 1.00±0.00 plus-or-minus 1.00 0.00 1.00\pm 0.00 1.00 ± 0.00 and mean PSNR of infinity. When accessing sub-resolution images, our results show that each subsequent decomposition results in increased image quality as indicated with increasing mean SIIM and PSNR values (\figureref fig:resultsc–d). At the smallest sub-resolution, we measured a mean SSIM of 0.83±0.06 plus-or-minus 0.83 0.06 0.83\pm 0.06 0.83 ± 0.06, ranging from 0.75±0.17 plus-or-minus 0.75 0.17 0.75\pm 0.17 0.75 ± 0.17 for MSD-Liver to 0.93±0.04 plus-or-minus 0.93 0.04 0.93\pm 0.04 0.93 ± 0.04 for UPENN-GBM. We measured a mean PSNR of 23.77±2.11 plus-or-minus 23.77 2.11 23.77\pm 2.11 23.77 ± 2.11, ranging from 21.18±1.96 plus-or-minus 21.18 1.96 21.18\pm 1.96 21.18 ± 1.96 for LIDC-IDRI to 27.22±3.02 plus-or-minus 27.22 3.02 27.22\pm 3.02 27.22 ± 3.02 for UPENN-GBM.

In addition to quantitative metrics of image quality, we performed a preliminary set of DL experiments across 2D classification and 3D segmentation tasks (Appendix C). Examples of sub-resolution images from each dataset are provided in \figureref fig:examples.

5 Discussion

We demonstrated that MIST can reduce the storage and bandwidth requirements for hosting and downloading large-scale medical imaging datasets across different body parts, modalities, and formats. While the decrease in data storage and transmission varies from one dataset to another, our results consistently showed a significant improvement in data-efficiency despite differences in pixel bit depth, resolution, and formats. We observed that MIST-encoded DICOM datasets had the greatest decrease in data storage followed by NIfTI and PNG. This is primarily for two reasons: 1) The DICOM datasets in our study stored uncompressed pixel data, resulting in a high compression ratio. 2) The NIfTI and PNG formats use lossless compression to encode pixel data. However, MIST is able to exceed the compression ratio of NIfTI while closely matching that of PNG [Elhadad et al.(2024)Elhadad, Jamjoom, and Abulkasim].

Our method goes a step further by also allowing streaming of medical images at different resolutions and formats from a single format-agnostic, high-resolution copy. Since every researcher has different needs and use cases, eliminating the preprocessing steps of image resizing and format conversion (e.g., DICOM to NIfTI) before training DL models can lead to greater resource-efficiency [Jia et al.(2023)Jia, Chen, Xu, Kheir, Hu, Xiao, Peng, Hu, Chen, and Shi]. Moreover, streaming sub-resolution images inherently leads to reduced data transmission to download medical imaging datasets. For example, if a researcher wanted to train a DL model using transfer learning (at resolution 224×224 224 224 224\times 224 224 × 224) with the NIH-ChestX-ray14 dataset, they would have to download 92%percent 92 92%92 % less data compared to current solutions.

Despite decreasing the amount of data stored and transmitted, we demonstrated that MIST-encoded datasets preserved image quality, indicated by a lossless reconstruction of pixel data, across different body parts, modalities, and formats. However, accessing sub-resolution images led to a decrease in image quality due to the lossy reconstruction of pixel data from partial bytestreams. When comparing with the original pixel data, differences in image quality metrics were due to variations in resizing methods, such as compression artifacts from progressive decoding vs bilinear interpolation in conventional downsampling. However, this does not inherently indicate a loss of image quality, but rather reflects the differences in resizing techniques [Botnari et al.(2024)Botnari, Kadar, and Patrascu]. In Appendix C and our prior work, we showed that sub-resolution images did not impact the performance of DL models across 2D classification and 3D segmentation tasks [Kulkarni et al.(2024)Kulkarni, Kanhere, Siegel, Yi, and Parekh].

There are some limitations of our work: 1) While we observe no impact on image quality using quantitive metrics, such as SSIM and PSNR, there is a need to further validate MIST-encoded datasets for training DL models. 2) Since we measured data-efficiency metrics for the entire dataset, where each image can have a different resolution and, thus, number of decomposition levels, the decrease in data storage and transmission may dramatically vary from one image to another. 3) Due to limitations in current HTJ2K implementation, we excluded series that contained unsupported pixel data. For example, n=28 𝑛 28 n=28 italic_n = 28 MRI volumes from AMOS exceeded the 16-bit pixel depth, potentially due to the presence of artifacts, and were excluded. 4) For NIfTI volumes, each slice is encoded and decoded as a separate image, adding an additional step to reconstruct the volume after decoding. 5) Further evaluation is required to identify the best approach of handling complex DICOM metadata. In our experiments, we used JSON to store metadata, but this may not scale efficiently when the metadata is complex. For future work, we intend to address these limitations and plan to extensively validate MIST in real-world research settings.

In conclusion, MIST is a crucial first step towards addressing the challenges posed by hosting and accessing large-scale medical imaging datasets, especially as datasets continue to grow in scale and resolution. Our work demonstrates that a data-efficient, format-agnostic database can not only reduce data storage and transmission, but also meet the diverse needs of researchers and reduce barriers to DL research in medical imaging.

References

  • [Aerts et al.(2014)Aerts, Velazquez, Leijenaar, Parmar, Grossmann, Carvalho, Bussink, Monshouwer, Haibe-Kains, Rietveld, et al.] Hugo JWL Aerts, Emmanuel Rios Velazquez, Ralph TH Leijenaar, Chintan Parmar, Patrick Grossmann, Sara Carvalho, Johan Bussink, René Monshouwer, Benjamin Haibe-Kains, Derek Rietveld, et al. Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach. Nature communications, 5(1):4006, 2014.
  • [Antonelli et al.(2022)Antonelli, Reinke, Bakas, Farahani, Kopp-Schneider, Landman, Litjens, Menze, Ronneberger, Summers, et al.] Michela Antonelli, Annika Reinke, Spyridon Bakas, Keyvan Farahani, Annette Kopp-Schneider, Bennett A Landman, Geert Litjens, Bjoern Menze, Olaf Ronneberger, Ronald M Summers, et al. The medical segmentation decathlon. Nature communications, 13(1):4128, 2022.
  • [Armato III et al.(2011)Armato III, McLennan, Bidaut, McNitt-Gray, Meyer, Reeves, Zhao, Aberle, Henschke, Hoffman, et al.] Samuel G Armato III, Geoffrey McLennan, Luc Bidaut, Michael F McNitt-Gray, Charles R Meyer, Anthony P Reeves, Binsheng Zhao, Denise R Aberle, Claudia I Henschke, Eric A Hoffman, et al. The lung image database consortium (lidc) and image database resource initiative (idri): a completed reference database of lung nodules on ct scans. Medical physics, 38(2):915–931, 2011.
  • [Bakas et al.(2022)Bakas, Sako, Akbari, Bilello, Sotiras, Shukla, Rudie, Santamaría, Kazerooni, Pati, et al.] Spyridon Bakas, Chiharu Sako, Hamed Akbari, Michel Bilello, Aristeidis Sotiras, Gaurav Shukla, Jeffrey D Rudie, Natali Flores Santamaría, Anahita Fathi Kazerooni, Sarthak Pati, et al. The university of pennsylvania glioblastoma (upenn-gbm) cohort: advanced mri, clinical, genomics, & radiomics. Scientific data, 9(1):453, 2022.
  • [Bilic et al.(2023)Bilic, Christ, Li, Vorontsov, Ben-Cohen, Kaissis, Szeskin, Jacobs, Mamani, Chartrand, et al.] Patrick Bilic, Patrick Christ, Hongwei Bran Li, Eugene Vorontsov, Avi Ben-Cohen, Georgios Kaissis, Adi Szeskin, Colin Jacobs, Gabriel Efrain Humpire Mamani, Gabriel Chartrand, et al. The liver tumor segmentation benchmark (lits). Medical image analysis, 84:102680, 2023.
  • [Boliek et al.(2000)Boliek, Christopoulos, and Majani] Martin Boliek, Charilaos Christopoulos, and Eric Majani. Jpeg 2000 image coding system, 2000. URL https://www.ics.uci.edu/~dan/class/267/papers/jpeg2000.pdf.
  • [Botnari et al.(2024)Botnari, Kadar, and Patrascu] A Botnari, M Kadar, and JM Patrascu. Considerations on image preprocessing techniques required by deep learning models. the case of the knee mris. Mædica, 19(3):526, 2024.
  • [Doo et al.(2024)Doo, Kulkarni, Siegel, Toland, Yi, Carlos, and Parekh] Florence X Doo, Pranav Kulkarni, Eliot L Siegel, Michael Toland, Paul H Yi, Ruth C Carlos, and Vishwa S Parekh. Economic and environmental costs of cloud technologies for medical imaging and radiology artificial intelligence. Journal of the American College of Radiology, 21(2):248–256, 2024.
  • [Elhadad et al.(2024)Elhadad, Jamjoom, and Abulkasim] Ahmed Elhadad, Mona Jamjoom, and Hussein Abulkasim. Reduction of nifti files storage and compression to facilitate telemedicine services based on quantization hiding of downsampling approach. Scientific Reports, 14(1):5168, 2024.
  • [Fedorov et al.(2021)Fedorov, Longabaugh, Pot, Clunie, Pieper, Aerts, Homeyer, Lewis, Akbarzadeh, Bontempi, et al.] Andrey Fedorov, William JR Longabaugh, David Pot, David A Clunie, Steve Pieper, Hugo JWL Aerts, André Homeyer, Rob Lewis, Afshin Akbarzadeh, Dennis Bontempi, et al. Nci imaging data commons. Cancer research, 81(16):4188–4193, 2021.
  • [Foos et al.(2000)Foos, Muka, Slone, Erickson, Flynn, Clunie, Hildebrand, Kohm, and Young] David H Foos, Edward Muka, Richard M Slone, Bradley J Erickson, Michael J Flynn, David A Clunie, Lloyd Hildebrand, Kevin S Kohm, and Susan S Young. Jpeg 2000 compression of medical imagery. In Medical Imaging 2000: PACS Design and Evaluation: Engineering and Clinical Issues, volume 3980, pages 85–96. SPIE, 2000.
  • [Galbusera and Cina(2024)] Fabio Galbusera and Andrea Cina. Image annotation and curation in radiology: an overview for machine learning practitioners. European Radiology Experimental, 8(1):11, 2024.
  • [Guo et al.(2015)Guo, Li, Zhu, Lan, Yang, Drukker, Morris, Burnside, Whitman, Giger, et al.] Wentian Guo, Hui Li, Yitan Zhu, Li Lan, Shengjie Yang, Karen Drukker, Elizabeth Morris, Elizabeth Burnside, Gary Whitman, Maryellen L Giger, et al. Prediction of clinical phenotypes in invasive breast carcinomas from the integration of radiomics and genomics data. Journal of medical imaging, 2(4):041007–041007, 2015.
  • [Hosny et al.(2018)Hosny, Parmar, Quackenbush, Schwartz, and Aerts] Ahmed Hosny, Chintan Parmar, John Quackenbush, Lawrence H Schwartz, and Hugo JWL Aerts. Artificial intelligence in radiology. Nature Reviews Cancer, 18(8):500–510, 2018.
  • [Ji et al.(2022)Ji, Bai, Ge, Yang, Zhu, Zhang, Li, Zhanng, Ma, Wan, et al.] Yuanfeng Ji, Haotian Bai, Chongjian Ge, Jie Yang, Ye Zhu, Ruimao Zhang, Zhen Li, Lingyan Zhanng, Wanling Ma, Xiang Wan, et al. Amos: A large-scale abdominal multi-organ benchmark for versatile medical image segmentation. Advances in neural information processing systems, 35:36722–36732, 2022.
  • [Jia et al.(2023)Jia, Chen, Xu, Kheir, Hu, Xiao, Peng, Hu, Chen, and Shi] Zhenge Jia, Jianxu Chen, Xiaowei Xu, John Kheir, Jingtong Hu, Han Xiao, Sui Peng, Xiaobo Sharon Hu, Danny Chen, and Yiyu Shi. The importance of resource awareness in artificial intelligence for healthcare. Nature Machine Intelligence, 5(7):687–698, 2023.
  • [Jiménez-Sánchez et al.(2024)Jiménez-Sánchez, Avlona, Juodelyte, Sourget, Vang-Larsen, Rogers, Zajac, and Cheplygina] Amelia Jiménez-Sánchez, Natalia-Rozalia Avlona, Dovile Juodelyte, Théo Sourget, Caroline Vang-Larsen, Anna Rogers, Hubert Dariusz Zajac, and Veronika Cheplygina. Copycats: the many lives of a publicly available medical imaging dataset. arXiv preprint arXiv:2402.06353, 2024.
  • [Johnson et al.(2019)Johnson, Pollard, Berkowitz, Greenbaum, Lungren, Deng, Mark, and Horng] Alistair EW Johnson, Tom J Pollard, Seth J Berkowitz, Nathaniel R Greenbaum, Matthew P Lungren, Chih-ying Deng, Roger G Mark, and Steven Horng. Mimic-cxr, a de-identified publicly available database of chest radiographs with free-text reports. Scientific data, 6(1):317, 2019.
  • [Kiryati and Landau(2021)] Nahum Kiryati and Yuval Landau. Dataset growth in medical image analysis research. Journal of imaging, 7(8):155, 2021.
  • [Koff and Shulman(2006)] David A Koff and Harry Shulman. An overview of digital compression of medical images: can we use lossy image compression in radiology? Journal-Canadian Association of Radiologists, 57(4):211, 2006.
  • [Kulkarni et al.(2024)Kulkarni, Kanhere, Siegel, Yi, and Parekh] Pranav Kulkarni, Adway Kanhere, Eliot L Siegel, Paul H Yi, and Vishwa S Parekh. Isle: An intelligent streaming framework for high-throughput ai inference in medical imaging. Journal of Imaging Informatics in Medicine, 37(6):3250–3263, 2024.
  • [Landman et al.(2015)Landman, Xu, Igelsias, Styner, Langerak, and Klein] Bennett Landman, Zhoubing Xu, J Igelsias, Martin Styner, T Langerak, and Arno Klein. Miccai multi-atlas labeling beyond the cranial vault–workshop and challenge. In Proc. MICCAI Multi-Atlas Labeling Beyond Cranial Vault—Workshop Challenge, volume 5, page 12, 2015.
  • [Li et al.(2023)Li, Zhu, Hua, Feng, Bennamoun, Li, Lu, Song, Shen, Xu, et al.] Johann Li, Guangming Zhu, Cong Hua, Mingtao Feng, Basheer Bennamoun, Ping Li, Xiaoyuan Lu, Juan Song, Peiyi Shen, Xu Xu, et al. A systematic collection of medical image datasets for deep learning. ACM Computing Surveys, 56(5):1–51, 2023.
  • [Li et al.(2016)Li, Morgan, Ashburner, Smith, and Rorden] Xiangrui Li, Paul S Morgan, John Ashburner, Jolinda Smith, and Christopher Rorden. The first step for neuroimaging data analysis: Dicom to nifti conversion. Journal of neuroscience methods, 264:47–56, 2016.
  • [Magudia et al.(2021)Magudia, Bridge, Andriole, and Rosenthal] Kirti Magudia, Christopher P Bridge, Katherine P Andriole, and Michael H Rosenthal. The trials and tribulations of assembling large medical imaging datasets for machine learning applications. Journal of digital imaging, 34:1424–1429, 2021.
  • [Noumeir and Pambrun(2011)] Rita Noumeir and Jean-François Pambrun. Using jpeg 2000 interactive protocol to stream a large image or a large image set. Journal of digital imaging, 24:833–843, 2011.
  • [Sabottke and Spieler(2020)] Carl F Sabottke and Bradley M Spieler. The effect of image resolution on deep learning in radiography. Radiology: Artificial Intelligence, 2(1):e190015, 2020.
  • [Shinagare et al.(2015)Shinagare, Vikram, Jaffe, Akin, Kirby, Huang, Freymann, Sainani, Sadow, Bathala, et al.] Atul B Shinagare, Raghu Vikram, Carl Jaffe, Oguz Akin, Justin Kirby, Erich Huang, John Freymann, Nisha I Sainani, Cheryl A Sadow, Tharakeswara K Bathala, et al. Radiogenomics of clear cell renal cell carcinoma: Preliminary findings of the cancer genome atlas–renal cell carcinoma (tcga–rcc) imaging research group. Abdominal imaging, 40:1684–1692, 2015.
  • [Taubman et al.(2019)Taubman, Naman, Mathew, Smith, and Watanabe] David Taubman, Aous Naman, Reji Mathew, Michael Smith, and O Watanabe. High throughput JPEG 2000 (HTJ2K): Algorithm, performance and potential. International Telecommunications Union (ITU), pages 15444–15, 2019.
  • [Taubman et al.(2020)Taubman, Naman, Mathew, Smith, Watanabe, and Lemieux] David Taubman, Aous Naman, Reji Mathew, Michael Smith, Osamu Watanabe, and Pierre-Anthony Lemieux. High throughput JPEG 2000 (HTJ2K) and the JPH file format: a primer. https://ds.jpeg.org/whitepapers/jpeg-htj2k-whitepaper.pdf, 2020.
  • [Team(2011)] National Lung Screening Trial Research Team. Reduced lung-cancer mortality with low-dose computed tomographic screening. New England Journal of Medicine, 365(5):395–409, 2011.
  • [Wang et al.(2017)Wang, Peng, Lu, Lu, Bagheri, and Summers] Xiaosong Wang, Yifan Peng, Le Lu, Zhiyong Lu, Mohammadhadi Bagheri, and Ronald M Summers. Chestx-ray8: Hospital-scale chest x-ray database and benchmarks on weakly-supervised classification and localization of common thorax diseases. In Proceedings of the IEEE conference on computer vision and pattern recognition, pages 2097–2106, 2017.
  • [Wang et al.(2004)Wang, Bovik, Sheikh, and Simoncelli] Zhou Wang, Alan C Bovik, Hamid R Sheikh, and Eero P Simoncelli. Image quality assessment: from error visibility to structural similarity. IEEE transactions on image processing, 13(4):600–612, 2004.

Appendix A Dataset Descriptions

NIH-ChestX-ray14 The National Institutes of Health (NIH) ChestX-ray14 dataset contains n=112,120 𝑛 112 120 n=112,120 italic_n = 112 , 120 frontal CXRs from 30,805 patients [Wang et al.(2017)Wang, Peng, Lu, Lu, Bagheri, and Summers]. Each CXR is annotated with the presence of up to 14 disease labels. The dataset is available in the PNG format and spans a total size of 41.96 GB.

MSD-Liver The Medical Segmentation Decathlon (MSD) is a collection of benchmark datasets for medical image segmentation, spanning 10 tasks across different body parts and modalities [Antonelli et al.(2022)Antonelli, Reinke, Bakas, Farahani, Kopp-Schneider, Landman, Litjens, Menze, Ronneberger, Summers, et al.]. The MSD-Liver dataset is the third task comprising of a subset of n=201 𝑛 201 n=201 italic_n = 201 abdominal portal venous phase CT scans from the 2017 Liver Tumor Segmentation (LiTS) challenge [Bilic et al.(2023)Bilic, Christ, Li, Vorontsov, Ben-Cohen, Kaissis, Szeskin, Jacobs, Mamani, Chartrand, et al.]. Additionally, voxel-level annotations for liver and liver tumors are provided for n=131 𝑛 131 n=131 italic_n = 131 CT scans. The dataset is available in the NIfTI format and spans a total size of 26.94 GB.

AMOS The Abdominal Multi-Organ Segmentation (AMOS) dataset contains n=600 𝑛 600 n=600 italic_n = 600 abdominal CT and MRI scans [Ji et al.(2022)Ji, Bai, Ge, Yang, Zhu, Zhang, Li, Zhanng, Ma, Wan, et al.]. Additionally, voxel-level annotations for 15 abdominal structures are provided for n=360 𝑛 360 n=360 italic_n = 360 scans. The dataset is available in the NIfTI format and spans a total size of 22.59 GB.

LIDC-IDRI The Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset contains n=1,308 𝑛 1 308 n=1,308 italic_n = 1 , 308 lung CT scans [Armato III et al.(2011)Armato III, McLennan, Bidaut, McNitt-Gray, Meyer, Reeves, Zhao, Aberle, Henschke, Hoffman, et al.]. Each scan has corresponding lesion annotations from up to four radiologists. The dataset is available in the DICOM format on TCIA and spans a total size of 124.00 GB.

NSCLC-Radiomics The Non-Small Cell Lung Cancer (NSCLC)-Radiomics dataset comprised of n=422 𝑛 422 n=422 italic_n = 422 lung CT scans [Aerts et al.(2014)Aerts, Velazquez, Leijenaar, Parmar, Grossmann, Carvalho, Bussink, Monshouwer, Haibe-Kains, Rietveld, et al.]. Each CT scans has corresponding segmentations and 440 extracted radiomics features. The dataset is available in the DICOM format on TCIA and spans a total size of 33.32 GB.

TCGA-KIRC The Cancer Genome Atlas Kidney Renal Clear Cell Carcinoma (TCGA-KIRC) dataset contains n=2,654 𝑛 2 654 n=2,654 italic_n = 2 , 654 abdominal CT and MRI scans [Shinagare et al.(2015)Shinagare, Vikram, Jaffe, Akin, Kirby, Huang, Freymann, Sainani, Sadow, Bathala, et al.]. The dataset is available in the DICOM format on TCIA and spans a total size of 85.28 GB.

TCGA-BRCA The Cancer Genome Atlas Breast Invasive Carcinoma (TCGA-BRCA) dataset contains n=1,877 𝑛 1 877 n=1,877 italic_n = 1 , 877 MRI scans and mammograms [Guo et al.(2015)Guo, Li, Zhu, Lan, Yang, Drukker, Morris, Burnside, Whitman, Giger, et al.]. Each scan has a corresponding standardized breast imaging report, genomic, and pathology data. The dataset is available in the DICOM format on TCIA and spans a total size of 82.08 GB.

UPENN-GBM the University of Pennsylvania Glioblastoma (UPENN-GBM) dataset contains n=3,680 𝑛 3 680 n=3,680 italic_n = 3 , 680 multi-parametric brain MRIs [Bakas et al.(2022)Bakas, Sako, Akbari, Bilello, Sotiras, Shukla, Rudie, Santamaría, Kazerooni, Pati, et al.]. Each scan has corresponding segmentations, radiomics, and pathology data. The dataset is available in the DICOM format on TCIA and spans a total size of 129.83 GB.

Appendix B Detailed Results

Table B.1: Encoding summary of all eight datasets

Table B.2: Mean data-efficiency and image quality metrics for NIH-ChestX-ray14 dataset.

Table B.3: Mean data-efficiency and image quality metrics for MSD-Liver dataset.

Table B.4: Mean data-efficiency and image quality metrics for AMOS dataset.

Table B.5: Mean data-efficiency and image quality metrics for LIDC-IDRI dataset.

Table B.6: Mean data-efficiency and image quality metrics for NSCLC-Radiomics dataset.

Table B.7: Mean data-efficiency and image quality metrics for TCGA-KIRC dataset.

Table B.8: Mean data-efficiency and image quality metrics for TCGA-BRCA dataset.

Table B.9: Mean data-efficiency and image quality metrics for UPENN-GBM dataset.

Appendix C Preliminary Deep Learning Experiments

We conducted two preliminary experiments to validate MIST-encoded sub-resolution images for training DL models. In both experiments, we trained two models at a fixed input resolution using the original and MIST-encoded images, then tested them on the original internal and external datasets respectively. The MIST-encoded images were decoded at the sub-resolution closest to the model’s input resolution.

C.1 2D Classification

We randomly split the NIH-ChestX-ray14 dataset on the patient-level into train (70%,n=78,075 formulae-sequence percent 70 𝑛 78 075 70%,n=78,075 70 % , italic_n = 78 , 075), validation (10%,n=11,079 formulae-sequence percent 10 𝑛 11 079 10%,n=11,079 10 % , italic_n = 11 , 079), and test (20%,n=22,966 formulae-sequence percent 20 𝑛 22 966 20%,n=22,966 20 % , italic_n = 22 , 966) sets. We used n=15,000 𝑛 15 000 n=15,000 italic_n = 15 , 000 randomly sampled frontal CXRs from the MIMIC-CXR dataset [Johnson et al.(2019)Johnson, Pollard, Berkowitz, Greenbaum, Lungren, Deng, Mark, and Horng] as our external test set. Then, we trained two ImageNet-pretrained DenseNet121 models at resolution 224×224 224 224 224\times 224 224 × 224, one on the original PNG images and the other on the sub-resolution images. Both models were trained for 100 epochs with binary cross-entropy loss, 64 batch size, 5e-5 learning rate, and random augmentations. We measured the performance of both models using the mean area under the receiver operating characteristic curve (AUROC) scores of seven labels: Atelectasis, Cardiomegaly, Consolidation, Edema, Pleural effusion, Pneumonia, and Pneumothorax. On the NIH-ChestX-ray14 test set, we observed that both the PNG-trained and MIST-trained models measured a mean AUROC of 0.84±0.05 plus-or-minus 0.84 0.05 0.84\pm 0.05 0.84 ± 0.05. When evaluated on the external MIMIC-CXR test set, both models similarly measured a mean AUROC of 0.76±0.07 plus-or-minus 0.76 0.07 0.76\pm 0.07 0.76 ± 0.07.

C.2 3D Segmentation

We randomly split the MSD-Liver dataset into train (80%,n=106 percent 80 𝑛 106 80%,n=106 80 % , italic_n = 106) and test (20%,n=25 percent 20 𝑛 25 20%,n=25 20 % , italic_n = 25) sets. We used n=30 𝑛 30 n=30 italic_n = 30 volumes from the BTCV dataset [Landman et al.(2015)Landman, Xu, Igelsias, Styner, Langerak, and Klein] as our external test set. Then, we trained two 3D-UNet models at resolution 256×256×128 256 256 128 256\times 256\times 128 256 × 256 × 128 and voxel spacing 1.5×1.5×2.0 1.5 1.5 2.0 1.5\times 1.5\times 2.0 1.5 × 1.5 × 2.0. Both models were trained using random foreground patches of resolution 128×128×32 128 128 32 128\times 128\times 32 128 × 128 × 32 for 500 epochs with Dice loss, 2 batch size, 1e-4 learning rate with cosine annealing scheduler, and random augmentations. We measured the performance of both models using the mean Dice score. On the MSD-Liver test set, we observed that the NIfTI-trained model measured a mean Dice score of 0.95±0.02 plus-or-minus 0.95 0.02 0.95\pm 0.02 0.95 ± 0.02, while the MIST-trained model measured a mean Dice score of 0.94±0.02 plus-or-minus 0.94 0.02 0.94\pm 0.02 0.94 ± 0.02. When evaluated on the external BTCV test set, both models measured a mean Dice score of 0.93±0.02 plus-or-minus 0.93 0.02 0.93\pm 0.02 0.93 ± 0.02.

Appendix D Visualization of Sub-Resolution Images

Image 4: Refer to caption

Figure D.1: Examples from MIST-encoded medical imaging datasets. The number of decompositions depends on the medical image’s resolution.

Xet Storage Details

Size:
52.6 kB
·
Xet hash:
67c92a20b9178f27aa0f557a0cf5f9e7ec9a3df437b677c74f5d1a2449233271

Xet efficiently stores files, intelligently splitting them into unique chunks and accelerating uploads and downloads. More info.