Answer this question truthfully
Bioabsorbable stents can be broadly classified into two types: polymeric and metallic types. The key features to be considered while selecting a polymer or an alloy for a bioabsorbable stent are:
Strength in order to avoid potential immediate recoil Rate of degradation and corrosion Biocompatibility with the vessel wall Lack of toxicity
Polymers have been widely used in cardiovascular devices and are now primarily used as delivery vehicles for drug coatings. Polymers used for bioabsorbable stents are Poly-L-Lactic acid(PLLA), polyglycolic acid(PGA),Poly(D,L-lactide/glycolide) copolymer(PDLA) and polycaprolactone. The use of bioabsorbable polymer coating reduces the need for extended dual anti-platelet therapy and in turn late thrombotic events. Among the polymers, Poly-L-Lactic acid is widely used in medicine. It breaks down to lactic acid a natural metabolite in human body, which enters krebs Cycle and is metabolized to carbon dioxide and water.
So far two bioabsorbable metals alloys have been proposed for this application: magnesium and iron. The factors that determine the biocompatibility of these alloys are their solubility and degradation products. Magnesium stents are made of 93% magnesium and 7% rare-earth-metals. Reasons for selecting magnesium include:
It is an essential element in the body. The alloy induces rapid endothelialization. It has low thrombogenicity. It has a lower degradation time of 2-3 months. It has calcium antagonist and antiarrhythmic properties. Is not associated with any adverse reactions.
The following is the list of some of the bioabsorbable stents that are currently under trials.
What do bioabsorbable stents refer to?
| 53,076 | [
0.037200927734375,
-0.2098388671875,
0.22216796875,
0.32080078125,
-0.89013671875,
0.2491455078125,
-0.254150390625,
0.0111541748046875,
0.88720703125,
0.313232421875,
0.25390625,
-0.3623046875,
0.431396484375,
-0.71630859375,
-0.52392578125,
1.0849609375,
-0.7236328125,
-1.1308593... | 37 |
Question: is this a 2) strong advice, 1) weak advice 0) no advice?
This is no advice
Solid cathode, liquid electrolyte systems such as the lithium/carbon monofluoride and lithium/manganese dioxide pacemakers have greater gravimetric energy density (watt h/mm3) and are therefore likely to be future cardiac pacemaker power sources10.
| 69,691 | [
0.08001708984375,
-0.0767822265625,
-0.156494140625,
0.42724609375,
-0.7607421875,
0.141357421875,
-0.040435791015625,
0.54443359375,
0.3408203125,
0.322998046875,
0.60205078125,
0.010650634765625,
0.2259521484375,
-0.96630859375,
-0.6201171875,
0.361083984375,
-0.312744140625,
-0.... | 37 |
Please summerize the given abstract to a title
Synthesis and characterization of a nano-formulation for long lasting sterilization effect
The current COVID-19 pandemic has increased the use of alcohol based hand sanitisers globally. These available alcohol based sanitisers cannot provide an antibacterial effect for an extended period of time, after the evaporation of ethanol. Hence, the need for a sanitiser with an anti-microbial activity combined with a long lasting effect is the need of the hour. In this study, we report the synthesis of a long lasting sanitiser from ozonated omega 9 fatty acid esters in an ethanolic medium. The formed vesicles made of the fatty acids have been characterized by DLS, Zeta potential, and time resolved fluorescence anisotropy studies. Ethanol although, provides an antibacterial effect, the effect is more pronounced in our prepared formulation owing to its high peroxide value that generates additional oxidative stress. Finally, this additional antimicrobial effect will have relevance in the current COVID-19 scenario in providing a long lasting hand sanitiser.
| 77,196 | [
-0.39111328125,
0.2064208984375,
0.2763671875,
0.6240234375,
-0.248291015625,
0.0247955322265625,
-0.25341796875,
0.30517578125,
-0.1085205078125,
0.890625,
0.27978515625,
-0.607421875,
-0.08538818359375,
-0.74072265625,
-0.24072265625,
-0.297119140625,
0.0110931396484375,
-0.73583... | 37 |
Please summerize the given abstract to a title
Thermostability, Tunability, and Tenacity of RNA as Rubbery Anionic Polymeric Materials in Nanotechnology and Nanomedicine-Specific Cancer Targeting with Undetectable Toxicity
RNA nanotechnology is the bottom-up self-assembly of nanometer-scale architectures, resembling LEGOs, composed mainly of RNA. The ideal building material should be (1) versatile and controllable in shape and stoichiometry, (2) spontaneously self-assemble, and (3) thermodynamically, chemically, and enzymatically stable with a long shelf life. RNA building blocks exhibit each of the above. RNA is a polynucleic acid, making it a polymer, and its negative-charge prevents nonspecific binding to negatively charged cell membranes. The thermostability makes it suitable for logic gates, resistive memory, sensor set-ups, and NEM devices. RNA can be designed and manipulated with a level of simplicity of DNA while displaying versatile structure and enzyme activity of proteins. RNA can fold into single-stranded loops or bulges to serve as mounting dovetails for intermolecular or domain interactions without external linking dowels. RNA nanoparticles display rubber- and amoeba-like properties and are stretchable and shrinkable through multiple repeats, leading to enhanced tumor targeting and fast renal excretion to reduce toxicities. It was predicted in 2014 that RNA would be the third milestone in pharmaceutical drug development. The recent approval of several RNA drugs and COVID-19 mRNA vaccines by FDA suggests that this milestone is being realized. Here, we review the unique properties of RNA nanotechnology, summarize its recent advancements, describe its distinct attributes inside or outside the body and discuss potential applications in nanotechnology, medicine, and material science.
| 77,236 | [
-0.2137451171875,
0.06256103515625,
0.2354736328125,
0.53515625,
-0.51806640625,
0.1602783203125,
-0.50244140625,
0.11798095703125,
0.297607421875,
0.86279296875,
0.6513671875,
-0.474365234375,
0.2247314453125,
-0.72216796875,
-0.619140625,
0.252685546875,
-0.2064208984375,
-0.8466... | 37 |
Please summerize the given abstract to a title
Clinically oriented Alzheimer's biosensors: expanding the horizons towards point-of-care diagnostics and beyond
The development of minimally invasive and easy-to-use sensor devices is of current interest for ultrasensitive detection and signal recognition of Alzheimer's disease (AD) biomarkers. Over the years, tremendous effort has been made on diagnostic platforms specifically targeting neurological markers for AD in order to replace the conventional, laborious, and invasive sampling-based approaches. However, the sophistication of analytical outcomes, marker inaccessibility, and material validity strongly limit the current strategies towards effectively predicting AD. Recently, with the promising progress in biosensor technology, the realization of a clinically applicable sensing platform has become a potential option to enable early diagnosis of AD and other neurodegenerative diseases. In this review, various types of biosensors, which include electrochemical, fluorescent, plasmonic, photoelectrochemical, and field-effect transistor (FET)-based sensor configurations, with better clinical applicability and analytical performance towards AD are highlighted. Moreover, the feasibility of these sensors to achieve point-of-care (POC) diagnosis is also discussed. Furthermore, by grafting nanoscale materials into biosensor architecture, the remarkable enhancement in durability, functionality, and analytical outcome of sensor devices is presented. Finally, future perspectives on further translational and commercialization pathways of clinically driven biosensor devices for AD are discussed and summarized.
| 77,304 | [
-0.2724609375,
-0.404052734375,
0.07269287109375,
0.8564453125,
-1.0693359375,
-0.3984375,
-0.0255279541015625,
-0.02777099609375,
0.60302734375,
0.5166015625,
0.2127685546875,
-0.59912109375,
0.47412109375,
-0.479736328125,
-0.403564453125,
0.422119140625,
-0.66064453125,
-0.11492... | 37 |
Please summerize the given abstract to a title
Photocatalytic Degradation of Plastic Waste: A Mini Review
Plastic waste becomes an immediate threat to our society with ever-increasing negative impacts on our environment and health by entering our food chain. Sunlight is known to be the natural energy source that degrades plastic waste at a very slow rate. Mimicking the role of sunlight, the photocatalytic degradation process could significantly accelerate the degradation rate thanks to the photocatalyst that drastically facilitates the photochemical reactions involved in the degradation process. This mini review begins with an introduction to the chemical compositions of the common plastic waste. The mechanisms of photodegradation of polymers in general were then revisited. Afterwards, a few photocatalysts were introduced with an emphasis on titanium dioxide (TiO(2)), which is the most frequently used photocatalyst. The roles of TiO(2) photocatalyst in the photodegradation process were then elaborated, followed by the recent advances of photocatalytic degradation of various plastic waste. Lastly, our perspectives on the future research directions of photocatalytic plastic degradation are present. Herein, the importance of catalytic photodegradation is emphasized to inspire research on developing new photocatalysts and new processes for decomposition of plastic waste, and then to increase its recycling rate particularly in the current pandemic with the ever-increasing generation of plastic waste.
| 77,333 | [
-0.52734375,
-0.006988525390625,
0.0183868408203125,
0.424072265625,
-0.509765625,
0.050048828125,
-0.43798828125,
0.29443359375,
0.693359375,
0.62841796875,
0.326904296875,
-0.53271484375,
0.55615234375,
-0.7431640625,
-0.6103515625,
0.023773193359375,
0.27880859375,
-0.4516601562... | 37 |
Please summerize the given abstract to a title
Toward Development of a Label-Free Detection Technique for Microfluidic Fluorometric Peptide-Based Biosensor Systems
The problems of chronic or noncommunicable diseases (NCD) that now kill around 40 million people each year require multiparametric combinatorial diagnostics for the selection of effective treatment tactics. This could be implemented using the biosensor principle based on peptide aptamers for spatial recognition of corresponding protein markers of diseases in biological fluids. In this paper, a low-cost label-free principle of biomarker detection using a biosensor system based on fluorometric registration of the target proteins bound to peptide aptamers was investigated. The main detection principle considered includes the re-emission of the natural fluorescence of selectively bound protein markers into a longer-wavelength radiation easily detectable by common charge-coupled devices (CCD) using a specific luminophore. Implementation of this type of detection system demands the reduction of all types of stray light and background fluorescence of construction materials and aptamers. The latter was achieved by careful selection of materials and design of peptide aptamers with substituted aromatic amino acid residues and considering troponin T, troponin I, and bovine serum albumin as an example. The peptide aptamers for troponin T were designed in silico using the «Protein 3D» (SPB ETU, St. Petersburg, Russia) software. The luminophore was selected from the line of ZnS-based solid-state compounds. The test microfluidic system was arranged as a flow through a massive of four working chambers for immobilization of peptide aptamers, coupled with the optical detection system, based on thick film technology. The planar optical setup of the biosensor registration system was arranged as an excitation-emission cascade including 280 nm ultraviolet (UV) light-emitting diode (LED), polypropylene (PP) UV transparent film, proteins layer, glass filter, luminophore layer, and CCD sensor. A laboratory sample has been created.
| 77,422 | [
-0.420654296875,
-0.1827392578125,
0.1300048828125,
0.98876953125,
-1.0205078125,
0.1229248046875,
-0.203857421875,
-0.28271484375,
0.1912841796875,
0.92822265625,
0.159912109375,
-0.56494140625,
-0.06512451171875,
-0.243896484375,
-0.513671875,
0.187744140625,
-0.2109375,
-0.78857... | 37 |
Please summerize the given abstract to a title
Single-Use Disposable Waste Upcycling via Thermochemical Conversion Pathway
Herein, the pyrolysis of two types of single-use disposable waste (single-use food containers and corrugated fiberboard) was investigated as an approach to cleanly dispose of municipal solid waste, including plastic waste. For the pyrolysis of single-use food containers or corrugated fiberboard, an increase in temperature tended to increase the yield of pyrolytic gas (i.e., non-condensable gases) and decrease the yield of pyrolytic liquid (i.e., a mixture of condensable compounds) and solid residue. The single-use food container-derived pyrolytic product was largely composed of hydrocarbons with a wide range of carbon numbers from C(1) to C(32), while the corrugated fiberboard-derived pyrolytic product was composed of a variety of chemical groups such as phenolic compounds, polycyclic aromatic compounds, and oxygenates involving alcohols, acids, aldehydes, ketones, acetates, and esters. Changes in the pyrolysis temperature from 500 °C to 900 °C had no significant effect on the selectivity toward each chemical group found in the pyrolytic liquid derived from either the single-use food containers or corrugated fiberboard. The co-pyrolysis of the single-use food containers and corrugated fiberboard led to 6 times higher hydrogen (H(2)) selectivity than the pyrolysis of the single-use food containers only. Furthermore, the co-pyrolysis did not form phenolic compounds or polycyclic aromatic compounds that are hazardous environmental pollutants (0% selectivity), indicating that the co-pyrolysis process is an eco-friendly method to treat single-use disposable waste.
| 77,439 | [
-0.50341796875,
0.380615234375,
0.314208984375,
0.5830078125,
-0.83056640625,
-0.01529693603515625,
-0.4931640625,
0.174560546875,
0.56396484375,
0.83544921875,
0.3095703125,
-0.83837890625,
0.66650390625,
-0.89990234375,
-0.475341796875,
0.074951171875,
-0.10247802734375,
-0.33178... | 37 |
Please summerize the given abstract to a title
Simultaneous degradation of glucocorticoids and sterilization using bubbling corona discharge plasma based systems: a promising terminal water treatment facility for hospital wastewater
Glucocorticoids (GCs) have drawn great concern due to their widespread contamination in the environment and application in treating patients with COVID-19. Due to the lack of data about GC removal using advanced treatment processes, a novel paralleling and bubbling corona discharge reactor (PBCD) combined with iron-loaded activated-carbon fibre (Fe-ACF) was addressed in this study to degrade GCs represented by hydrocortisone (HC) and betamethasone (BT). The results showed that the PBCD-based system can degrade GCs effectively and can achieve effective sterilization. The removal rates of GCs were ranked as PBCD/Fe-ACF > PBCD/ACF > PBCD. The concentration of E. coli was reduced from 109 to 102 CFU/mL after 60 min of PBCD-based system treatment. The abundance of bacteria in actual hospital wastewater (HWW) was significantly reduced. Plasma changed the physical and chemical properties of ACF and Fe-ACF by etching axial grooves and enhancing stretching vibrations of surface functional groups, thus promoting adsorption and catalytic degradation. For GC degradation, the functional reactive species were identified as •OH, 1O2, and •O2 radicals. Possible degradation pathways for HC and BT were proposed, which mainly included defluorination, keto acid decarboxylation, demethylation, intramolecular cyclization, cleavage and ester hydrolysis, indicating a reduction in GC toxicity. Since GCs are widely used in patients with COVID-19 and their wastewater needs to be sterilized simultaneously, the intensive and electrically driven PBCD-based system is promising in GC pollution control and sterilization in terminal water treatment facilities.
| 77,571 | [
-0.18896484375,
-0.175537109375,
0.53466796875,
0.6455078125,
-0.5478515625,
-0.1317138671875,
-0.055816650390625,
0.07440185546875,
0.525390625,
0.443115234375,
0.281005859375,
-0.35400390625,
0.1685791015625,
-0.77197265625,
-0.44970703125,
-0.308349609375,
-0.347412109375,
-0.82... | 37 |
Please summerize the given abstract to a title
Phonon-Induced Relocation of Valence Charge in Boron Nitride Observed by Ultrafast X-Ray Diffraction
The impact of coherent phonon excitations on the valence charge distribution in cubic boron nitride is mapped by femtosecond x-ray powder diffraction. Zone-edge transverse acoustic (TA) two-phonon excitations generated by an impulsive Raman process induce a steplike increase of diffracted x-ray intensity. Charge density maps derived from transient diffraction patterns reveal a spatial transfer of valence charge from the interstitial region onto boron and nitrogen atoms. This transfer is modulated with a frequency of 250 GHz due to a coherent superposition of TA phonons related to the ^{10}B and ^{11}B isotopes. Nuclear and electronic degrees of freedom couple through many-body Coulomb interactions.
| 77,643 | [
-0.3564453125,
0.08978271484375,
-0.10577392578125,
0.356201171875,
-0.47021484375,
-0.279296875,
-0.50537109375,
-0.2744140625,
0.12078857421875,
0.78662109375,
0.6865234375,
-0.3427734375,
0.86767578125,
-1.1083984375,
-0.35791015625,
0.49609375,
-0.2369384765625,
-0.57080078125,... | 37 |
Please summerize the given abstract to a title
Curvature effects in charge-regulated lipid bilayers
We formulate a theory of electrostatic interactions in lipid bilayer membranes where both monolayer leaflets contain dissociable moieties that are subject to charge regulation. We specifically investigate the coupling between membrane curvature and charge regulation of a lipid bilayer vesicle using both the linear Debye-H\"uckel (DH) and the non-linear Poisson-Boltzmann (PB) theory. We find that charge regulation of an otherwise symmetric bilayer membrane can induce charge symmetry breaking, non-linear flexoelectricity and anomalous curvature dependence of free energy. The pH effects investigated go beyond the paradigm of electrostatic renormalization of the mechano-elastic properties of membranes.
| 77,647 | [
-0.1982421875,
-0.08380126953125,
0.428466796875,
0.82373046875,
-0.52978515625,
-0.106201171875,
-0.032806396484375,
0.0711669921875,
-0.063720703125,
1.37890625,
0.66259765625,
-0.28369140625,
0.1942138671875,
-0.84130859375,
-0.460205078125,
0.27587890625,
0.353759765625,
-0.413... | 37 |
Please summerize the given abstract to a title
Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station
The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other trans-iron elements, therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than $ \sim$ 3 GeV/n are available at present in the literature and they are affected by strong limitations in both energy reach and statistics. In this paper we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number $ Z $ = 40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This paper follows our previous measurement of the iron spectrum [O. Adriani et al., Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV$ /n $ our present data are compatible within the errors with a single power law with spectral index $ -2.51 \pm 0.07 $.
| 77,703 | [
-0.08447265625,
0.228515625,
-0.0187225341796875,
0.297119140625,
-0.55712890625,
-0.0236663818359375,
-0.134521484375,
0.03955078125,
0.08428955078125,
0.72119140625,
0.4814453125,
-0.422119140625,
0.392333984375,
-1.287109375,
-0.433349609375,
-0.09344482421875,
-0.422607421875,
... | 37 |
End of preview. Expand
in Data Studio
- Downloads last month
- 9