69 | FortiGate 7121F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
Errors
2: Alerts + Errors +
Verbose + Low-Level
Errors + PI traffic
3: Alerts + Errors +
Verbose + Low-Level
Errors + PI traffic +
IPMB traffic + LAN
Interface traffic
4: Same as 3
Display the SMM
time. Available o... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
70 | FortiGate 7121F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
IPMI <channel>. If a
<channel> is not
specified the
privilege level is set
for all IPMI channels.
Available on the
passive module.
View a summary of
users.
N/A user summary
User test command. N/A user test
Display ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
71 | FortiGate 7121F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
chassis
Get chassis sttatus N/A chassis status
Display the LAN
configuration.
Available on the
passive module.
lan print <channel>
Set LAN
configuration. The
kgkey and krkey
options are used for
RCMP+.
lan set <cha... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
72 | Cautions and warnings Fortinet Technologies Inc.
Cautions and warnings
Environmental specifications
Rack Mount Instructions - The following or similar rack-mount instructions are included with the installation instructions:
Instructions de montage en rack - Les instructions de montage en rack suivantes ou similaires so... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
73 | Cautions and warnings Fortinet Technologies Inc.
Serveur-blades, cartes et modems doivent être des accessoires listés ou commutateurs, processeurs, serveurs et
similaire blades ou cartes doivent être listé UL ou équivalent.
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperatu... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
74 | Cautions and warnings Fortinet Technologies Inc.
WARNUNG:
Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder
gleichwertigen Typ. Batterien gemäß den Anweisungen des Herstellers entsorgen.
Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechani... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
75 | Regulatory notices Fortinet Technologies Inc.
Regulatory notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference rec... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
76 | Regulatory notices Fortinet Technologies Inc.
Voluntary Control Council for Interference (VCCI) – Japan
この装置は、クラスA機器です。この装置を住宅環境で使用すると電波妨害を引き起こすことがあります。この場合には使用
者が適切な対策を講ずるよう要求されることがあります。VCCI-A
Product Safety Electrical Appliance & Material (PSE) – Japan
日本では電気用品安全法(PSE)の規定により、同梱している電源コードは本製品の専用電源コードとして利用し、他の製
品に使用しないで... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
77 | Regulatory notices Fortinet Technologies Inc.
China
此为A级产品,在生活环境中,该产品可能会造成无线电干扰。这种情况下,可能需要用户对其采取切实可行的
措施。
Agência Nacional de Telecomunicações (ANATEL) – Brazil (for the
FortiGate 7121F AC model)
Este produto não é apropriado para uso em ambientes domésticos, pois poderá causar interferências eletromagnéticas
que obrig... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
78 | Regulatory notices Fortinet Technologies Inc.
FortiGate-7121F 7.4.4 System Guide 79 | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
79 | Regulatory notices Fortinet Technologies Inc.
FortiGate-7121F 7.4.4 System Guide 80 | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
80 | Copyright© 2024 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the
U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other prod... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/c7e69026-9283-11eb-b70b-00505692583a/fortigate-7121F-system-guide.pdf |
0 | FortiGate 7081F System Guide
FortiGate-7000F Series | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
1 | FORTINET DOCUMENT LIBRARY
https://docs.fortinet.com
FORTINET VIDEO GUIDE
https://video.fortinet.com
FORTINET BLOG
https://blog.fortinet.com
CUSTOMER SERVICE & SUPPORT
https://support.fortinet.com
FORTINET TRAINING & CERTIFICATION PROGRAM
https://www.fortinet.com/training-certification
NSE INSTITUTE
https://training.for... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
2 | TABLE OF CONTENTS
Change log 6
FortiGate 7081F chassis 7
FortiGate 7081F front panel 7
FIM-7941F interface module 8
FIM-7921F interface module 10
FPM-7620F processor module 11
FortiGate 7081F back panel 11
Registering your FortiGate 7081F 13
FortiGate-7081F chassis schematic 13
Chassis hardware information 14
Shipping ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
3 | Fortinet Technologies Inc.
Getting started with FortiGate 7081F 36
Configuring the SLBC management interface 37
Confirming startup status 37
Multi VDOM mode 37
Changing data interface network settings 38
Changing the FortiGate 7081F log disk and RAID configuration 38
Resetting to factory defaults 39
Restarting the Fort... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
4 | Fortinet Technologies Inc.
European Conformity (CE) - EU 67
Voluntary Control Council for Interference (VCCI) – Japan 68
Product Safety Electrical Appliance & Material (PSE) – Japan 68
Bureau of Standards Metrology and Inspection (BSMI) – Taiwan 68
China 69
Agência Nacional de Telecomunicações (ANATEL) – Brazil (for th... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
5 | Change log Fortinet Technologies Inc.
Change log
Date Change description
September 25, 2023 Added more information to the disclaimer notes at the start of the following sections:
l Power consumption for different FIM-7921F FortiGate 7081F configurations on
page 20.
l Power consumption for different FIM-7941F FortiGate ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
6 | FortiGate 7081F chassis
The FortiGate 7081F is a 12U 19-inch rackmount 8-slot chassis with a 1Tbps fabric backplane and 50Gbps base
backplane designed by Fortinet. The fabric backplane provides network data communication among chassis slots and
the base backplane provides management and synchronization communication am... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
7 | FortiGate 7081F chassis Fortinet Technologies Inc.
FortiGate 7081F front panel showing AC PSUs, two FIM-7941Fs, and six FPM-7620Fs. The FortiGate 7081F
also supports FIM-7921Fs (not shown).
7
5
3
1
2
4
6
8
7
5
3
1
2
4
6
8
1 2 3 6 4 5
200-240VAC
16A 50-60Hz EACH
SHOCK HAZARD
DISCONNECT ALL
POWER SOURCES.
RISQUE
D’ÉLECTR... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
8 | FortiGate 7081F chassis Fortinet Technologies Inc.
processors to load balance millions of data sessions over the FortiGate 7000F 400Gbps fabric backplane channel to
FPM processor modules. The FIM-7941F also includes a 50Gbps base backplane channel for base backplane
management communication with each FPM in the chassis... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
9 | FortiGate 7081F chassis Fortinet Technologies Inc.
FIM-7921F interface module
The FIM-7921F interface module is a hot swappable module that provides data, management, and session
sync/heartbeat interfaces, base backplane switching, hardware acceleration, and fabric backplane session-aware load
balancing for a FortiGate... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
10 | FortiGate 7081F chassis Fortinet Technologies Inc.
FPM-7620F processor module
The FPM-7620F processor module is a high-performance worker module that processes sessions load balanced to it by
FIMs over the chassis fabric backplane. The FPM-7620F includes two 400Gbps data connections to the FIMs over the
chassis fabric ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
11 | FortiGate 7081F chassis Fortinet Technologies Inc.
FortiGate 7081F back panel
Chassis
Ground
Connector
Fan Tray 3 Fan Tray 2 Fan Tray 1
FortiGate 7081F 7.0.5 System Guide 12 | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
12 | FortiGate 7081F chassis Fortinet Technologies Inc.
Registering your FortiGate 7081F
FortiGate 7000F series products are registered according to the chassis serial number. You need to register your
chassis to receive Fortinet customer services such as product updates and customer support. You must also register
your pro... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
13 | FortiGate 7081F chassis Fortinet Technologies Inc.
Each FIM and FPM and the SMMs have a Shelf Management Controller (SMC). These SMCs support IPMB
communication between the active SMM and the FIMs and FPMs and other chassis components for storing and sharing
sensor data that the SMM uses to control chassis cooling and ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
14 | FortiGate 7081F chassis Fortinet Technologies Inc.
l One set of 4-post rack mounting components.
l One set of 2-post rack mounting components.
l Sixteen M4x8 flat-head screws.
l Two M4x6 pan-head screws.
l Eight rubber feet.
l Two USB to RJ-45 RS-232 console cables.
l One RJ-45 Ethernet cable.
Optional accessories and ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
15 | FortiGate 7081F chassis Fortinet Technologies Inc.
Power supplied by each PSU 2500W
Max Power Consumption 7300W
Average Power Consumption 6100W
Max AC Current 6 x 16A
Max DC Current 6 x 26-21A
Heat Dissipation 26283KJ/h (24900BTU/h)
Cooling fans, cooling air flow, and minimum clearance
The FortiGate 7081F chassis conta... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
16 | FortiGate 7081F chassis Fortinet Technologies Inc.
Cooling Fan Tray
Retention
Screw
Fan
LED
Retention
Screw
Retention
Screw
Retention
Screw
Cooling air flow and required minimum air flow clearance
When installing the chassis, make sure there is enough clearance for effective cooling air flow. The following diagram
show... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
17 | FortiGate 7081F chassis Fortinet Technologies Inc.
FortiGate 7081F cooling air flow and minimum air flow clearance
Cool air
Intake
Front FortiGate-7081F chassis (side View)
Fan
Trays
100 mm
675.5 mm
Warm Air
Exhaust
Back
100 mm
Cool air enters the chassis through the chassis front panel and warm air exhausts out the ba... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
18 | FortiGate 7081F chassis Fortinet Technologies Inc.
Power consumption for different FIM-7941F FortiGate 7081F
configurations
The tables in this section provide information about how to calculate maximum power consumption for a FortiGate
7081F system with two FIM-7941Fs and with two or six FPM-7620Fs.
These example calcu... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
19 | FortiGate 7081F chassis Fortinet Technologies Inc.
To completely power a FortiGate 7081F with two FIM-7941Fs and six FPM-7620Fs you would need three PSUs. You
can add more PSUs to provide 3+1, 3+2, or 3+3 redundancy.
Power consumption for different FIM-7921F FortiGate 7081F
configurations
The tables in this section pro... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
20 | FortiGate 7081F chassis Fortinet Technologies Inc.
Module Max power
consumption (W)
Number of
modules
Total max power (W)
FIM-7921F 597 2 1194
FPM-7620F 716 6 4296
Chassis (fans, SMMs
etc)
1340 N/A 1340
Totals 6830
To completely power a FortiGate 7081F with two FPM-7620Fs and six FPM-7620Fs you would need three PSUs. Y... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
21 | FortiGate 7081F chassis Fortinet Technologies Inc.
The PSU LED indicates whether the PSU is operating correctly and connected to power. If this LED is not lit, check to
make sure the PSU is connected to power. If the power connection is good then the PSU has failed and should be
replaced.
AC PSU LED states
The PSU LED ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
22 | FortiGate 7081F chassis Fortinet Technologies Inc.
Hot Swapping an AC PSU
Follow these steps to safely hot swap an AC PSU.
You can hot swap a PSU without powering down the FortiGate 7081F as long as four PSUs
are connected to power and operating normally. If you need to hot swap one of four operating
PSUs, you must pow... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
23 | FortiGate 7081F chassis Fortinet Technologies Inc.
DC PSU
Latch
LED
Power
Connector
To connect the FortiGate 7081F directly to data center power, Fortinet supplies custom DC power cables that connect to
the two-prong power connector on each DC PSU. The connector clicks into a release tab that secures the cable into
pla... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
24 | FortiGate 7081F chassis Fortinet Technologies Inc.
State Description
Flashing amber Warning that power input or output, temperature, or fan operation is close to being
outside of the normal operating range. This may be caused by a problem with the
PSU. This could also be caused by conditions external to the PSU, for ex... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
25 | FortiGate 7081F chassis Fortinet Technologies Inc.
-48VDC
RTN + RTN
(red)
-48VDC
(black)
DC power terminals
PSU connector
Release tab
Supplied power cable
You need the following equipment to connect the FortiGate 7081F DC PSUs to DC power:
l An electrostatic discharge (ESD) preventive wrist strap with connection cord.
... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
26 | FortiGate 7081F chassis Fortinet Technologies Inc.
Slide the connector in until the release tab clicks, locking the cable in place.
6. Turn on power to the PSU.
7. Verify that the PSU status LED is solid green meaning that the PSU is powered up and operating normally.
Connecting the FortiGate 7081F chassis to ground
Th... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
27 | FortiGate 7081F hardware assembly and rack mounting
The FortiGate 7081F chassis must be mounted in a standard 19-inch rack and requires 12U of vertical space in the rack.
This chapter describes how to attach accessories to the FortiGate 7081F chassis, how to install the chassis in a 4-post or
2-post rack, and how to in... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
28 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Cable bracket kit
You can install the optional cable bracket kit to help manage the network cables connected to FIMs and FPMs installed
in the FortiGate 7081F. Attach the cable bracket kit to the left and right front mounting brackets.
The c... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
29 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Attaching network cables to the cable mount levers
Maintain a greater than 1-inch
(2.5-cm) network cable
bend radius
Cable management
Tie cables to the mount lever
using the second round of the
cable tie.
Attach cable ties to the mount lev... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
30 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Front air filter kit
You can attach a front air filter kit if the FortiGate 7081F will be installed in a dusty environment. The following diagrams
show how to install the filter kit, special procedures for installing an FPM in slot 7, power ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
31 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Front air filter kit data and power cable management
Managing AC power cords
1. Connect AC power cords to
the PSUs and cable clamps.
2. Run the power cords out the
side seals at the bottom of both
filter kit side brackets.
Rubber
retainer
In... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
32 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Mounting the FortiGate 7081F chassis in a four-post rack
The FortiGate 7081F package includes a set of extendable rack mount trays that you can use to mount the chassis in a
4-post rack. Install the brackets to create a 4-post rack mount tra... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
33 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Mounting the FortiGate 7081F chassis in a two-post rack
The FortiGate 7081F package includes two mid mount trays and two mid-mount brackets that you can use to mount the
chassis in a 2-post rack. As shown in the diagram, first attach the mid... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
34 | FortiGate 7081F hardware assembly and rack mounting Fortinet Technologies Inc.
Inserting FIMs and FPMs
All FortiGate 7081F chassis are shipped with a protective front panel installed in the chassis to protect internal chassis
components. This panel must be removed before you install FIMs and FPMs.
Insert FIMs into chas... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
35 | Getting started with FortiGate 7081F
Begin by installing your FortiGate 7081F chassis in a rack and installing FIMs and FPMs in it. Then you can power on the
chassis and all modules in the chassis will power up.
Whenever a chassis is first powered on, it takes about 5 minutes for all modules to start up and become comp... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
36 | Getting started with FortiGate 7081F Fortinet Technologies Inc.
Configuring the SLBC management interface
To be able to use FortiGate 7081F special SLBC management interface features, such as being able to log into any FIM
or FPM using the management interface IP address and a special port number, you need to use the f... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
37 | Getting started with FortiGate 7081F Fortinet Technologies Inc.
so on. You can also add VLANs to the interfaces in mgmt-vdom and you can create LAGs that include the interfaces in
mgmt-vdom.
You can use the root VDOM for data traffic and you can also add more VDOMs as required, depending on your Multi
VDOM license.
Cha... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
38 | Getting started with FortiGate 7081F Fortinet Technologies Inc.
RAID Status: OK
RAID Size: 4000GB
Disk 1: OK Used 3815GB
Disk 2: OK Used 3815GB
Resetting to factory defaults
At any time during the configuration process, if you run into problems, you can reset the FortiGate 7081F to factory
defaults and start over. From... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
39 | Managing individual FortiGate 7081F FIMs and FPMs
You can manage individual FIMs and FPMs using special port numbers or the execute load-balance slot
manage command. You can also use the execute ha manage command to log in to the other FortiGate 7081F in an
HA configuration.
Special management port numbers
In some case... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
40 | Managing individual FortiGate 7081F FIMs and FPMs Fortinet Technologies Inc.
To verify which FIM or FPM you have logged into, the GUI header banner and the CLI prompt shows its hostname. The
System Information dashboard widget also shows the host name and serial number. The CLI prompt also shows the slot
address in the... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
41 | Managing individual FortiGate 7081F FIMs and FPMs Fortinet Technologies Inc.
Chassis and
Slot Number
Slot Address HTTP
(80)
HTTPS (443) Telnet
(23)
SSH (22) SNMP (161)
Ch2 slot 7 FPM07 8027 44327 2327 2227 16127
Ch2 slot 5 FPM05 8025 44325 2325 2225 16125
Ch2 slot 3 FPM03 8023 44323 2323 2223 16123
Ch2 slot 1 FIM01 802... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
42 | Firmware upgrades
In addition to introducing the basics of upgrading FortiGate 7081F firmware, this section describes how to:
l Upgrade the firmware running on individual FIMs and FPMs.
l Upgrade individual FIM or FPM firmware from the BIOS.
Firmware upgrade basics
All of the FIMs and FPMs in your FortiGate 7081F syste... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
43 | Firmware upgrades Fortinet Technologies Inc.
Fortinet recommends that you review the services provided by your FortiGate 7081F before a
firmware upgrade and then again after the upgrade to make sure the services continues to
operate normally. For example, you might want to verify that you can successfully access an
imp... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
44 | Firmware upgrades Fortinet Technologies Inc.
the FIM or FPM is synchronized. In_sync=0 means the FIM or FPM is not synchronized, which could indicated the
FIM or FPM is running a different firmware build than the primary FIM.
The procedures in this section work for FIMs or FPMs in a standalone FortiGate 7081F. These pr... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
45 | Firmware upgrades Fortinet Technologies Inc.
FIMs and FPMs that are missing or that show in_sync=0 are not synchronized. To synchronize an FIM or FPM
that is not synchronized, log into the CLI of the FIM or FPM and restart it using the execute reboot command. If
this does not solve the problem, contact Fortinet Support... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
46 | Firmware upgrades Fortinet Technologies Inc.
1. Set up a TFTP server and copy the firmware file to the TFTP server default folder.
2. Set up your network to allow traffic between the TFTP server and one of the FIM MGMT interfaces.
3. Using the console cable supplied with your FortiGate 7081F, connect the SMM Console 1 ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
47 | Firmware upgrades Fortinet Technologies Inc.
Installing FPM firmware from the BIOS after a reboot
Use the following procedure to upload firmware from a TFTP server to an FPM. To perform the upgrade, you must first
upload the firmware file to the TFTP server on one of the FIMs.
This procedure also involves connecting to... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
48 | Firmware upgrades Fortinet Technologies Inc.
[G]: Set local gateway: 169.254.254.1.
[V]: Local VLAN ID: Should be set to <none>. (use -1 to set the Local VLAN ID to <none>.)
[T]: Set remote TFTP server IP address: The internal IP address of the FIM that you uploaded to the
firmware file to. For example: 169.254.254.1 f... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
49 | Firmware upgrades Fortinet Technologies Inc.
Synchronizing FIMs and FPMs after upgrading the primary FIM
firmware from the BIOS
After you install firmware on the primary FIM from the BIOS after a reboot, the firmware version and configuration of the
primary FIM will most likely be not be synchronized with the other FIM... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
50 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
FortiGate 7081F System Management Module
The FortiGate 7081F chassis includes two System Management Modules (SMMs) or shelf managers, located at the top
of the chassis front panel. The SMMs are factory installed and configured and are not field replace... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
51 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
authorization from the active SMM and the active SMM controls the power supplied by the chassis power systems to the
modules.
Each module in the chassis includes its own module Shelf Manager Controller (SMC) Serial Debug Interface (SDI) or
SMC SDI cons... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
52 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
LED State Description
Temp Solid green All temperature sensors indicated acceptable operating temperatures.
Blinking green At least one temperature sensor is detecting a high temperature outside of the
normal operating range. In this case an upper non-... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
53 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
About SMM alarm levels
Minor, major, and critical alarms are defined based on both IPMI, ATCA, and Telco standards for naming alarms.
l A minor alarm (also called an IPMI non-critical (NC) alarm) indicates that a temperature or a power level was
detect... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
54 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
press would cause a conflict that module is skipped. If one of the console ports is disconnected then the other console
port can connect to any CLI.
If you connect a PC to one of the SMM console ports with a serial cable and open a terminal session you... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
55 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
5. Login with an administrator name and password.
The default is admin with no password.
For security reasons, it is strongly recommended that you change the password.
6. When your session is complete, enter the exit command to log out.
Connecting to t... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
56 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
Chassis slot number Name IPMB Address (FRUID)
SMM 1 MGMT1 if active 0x20, if passive (the
default) 0x22
SMM 2 MGMT2 if active (the default) 0x20, if
passive 0x22
7 FPM7 0x8E
5 FPM5 0x8A
3 FPM3 0x86
1 FIM1 0x82
2 FIM2 0x84
4 FPM4 0x88
6 FPM6 0x8C
8 FPM8... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
57 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
Header Cause
\n--- COMLOG SYSTEM BOOT: YYYY/MM/DD hh:mm:ss ---\n The module is starting up after being powered on or
reset.
\n--- COMLOG DISABLED: YYYY/MM/DD hh:mm:ss ---\n Logging is disabled.
\n--- COMLOG ENABLED: YYYY/MM/DD hh:mm:ss ---\n Logging is... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
58 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
System event log (SEL)
The SMC in each FIM and FPM generates system event log (SEL) messages that record system events as they occur.
All SEL messages are stored by individual FIM and FPM SMCs. They are also all collected and stored by the SMM SMC.
Fro... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
59 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
<slot> option is not available on the passive SMM.
Action SMC CLI Commands IPMI Commands
Log into the CLI. Ctrl-R N/A
Log out of the CLI.
Available on the
passive module.
exit (followed by Ctrl-R) N/A
Display all
commands.
Available on the
passive modu... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
60 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
Errors
2: Alerts + Errors +
Verbose + Low-Level
Errors + PI traffic
3: Alerts + Errors +
Verbose + Low-Level
Errors + PI traffic +
IPMB traffic + LAN
Interface traffic
4: Same as 3
Display the SMM
time. Available o... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
61 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
IPMI <channel>. If a
<channel> is not
specified the
privilege level is set
for all IPMI channels.
Available on the
passive module.
View a summary of
users.
N/A user summary
User test command. N/A user test
Display ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
62 | FortiGate 7081F System Management Module Fortinet Technologies Inc.
Action SMC CLI Commands IPMI Commands
chassis
Get chassis sttatus N/A chassis status
Display the LAN
configuration.
Available on the
passive module.
lan print <channel>
Set LAN
configuration. The
kgkey and krkey
options are used for
RCMP+.
lan set <cha... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
63 | Cautions and warnings Fortinet Technologies Inc.
Cautions and warnings
Environmental specifications
Rack Mount Instructions - The following or similar rack-mount instructions are included with the installation instructions:
Instructions de montage en rack - Les instructions de montage en rack suivantes ou similaires so... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
64 | Cautions and warnings Fortinet Technologies Inc.
Serveur-blades, cartes et modems doivent être des accessoires listés ou commutateurs, processeurs, serveurs et
similaire blades ou cartes doivent être listé UL ou équivalent.
Refer to specific Product Model Data Sheet for Environmental Specifications (Operating Temperatu... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
65 | Cautions and warnings Fortinet Technologies Inc.
Lithium-Batterie Achtung: Explosionsgefahr bei fehlerhafter Batteriewechsel. Ersetzen Sie nur den gleichen oder
gleichwertigen Typ. Batterien gemäß den Anweisungen des Herstellers entsorgen.
Beseitigung einer BATTERIE in Feuer oder einen heißen Ofen oder mechanisches Zer... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
66 | Regulatory notices Fortinet Technologies Inc.
Regulatory notices
Federal Communication Commission (FCC) – USA
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference rec... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
67 | Regulatory notices Fortinet Technologies Inc.
Voluntary Control Council for Interference (VCCI) – Japan
この装置は、クラスA機器です。この装置を住宅環境で使用すると電波妨害を引き起こすことがあります。この場合には使用
者が適切な対策を講ずるよう要求されることがあります。VCCI-A
Product Safety Electrical Appliance & Material (PSE) – Japan
日本では電気用品安全法(PSE)の規定により、同梱している電源コードは本製品の専用電源コードとして利用し、他の製
品に使用しないで... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
68 | Regulatory notices Fortinet Technologies Inc.
China
警告: 在居住环境中,运行此设备可能会造成无线电干扰。
Agência Nacional de Telecomunicações (ANATEL) – Brazil (for the
FortiGate 7081F AC model)
Este produto não é apropriado para uso em ambientes domésticos, pois poderá causar interferências eletromagnéticas
que obrigam o usuário a tomar medid... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
69 | Regulatory notices Fortinet Technologies Inc.
FortiGate 7081F 7.0.5 System Guide 70 | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
70 | Regulatory notices Fortinet Technologies Inc.
FortiGate 7081F 7.0.5 System Guide 71 | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
71 | Copyright© 2023 Fortinet, Inc. All rights reserved. Fortinet®, FortiGate®, FortiCare® and FortiGuard®, and certain other marks are registered trademarks of Fortinet, Inc., in the
U.S. and other jurisdictions, and other Fortinet names herein may also be registered and/or common law trademarks of Fortinet. All other prod... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/17ef7271-b6d2-11ed-8e6d-fa163e15d75b/fortigate-7081F-system-guide.pdf |
0 | FortiGate-7060E System Guide
FortiGate-7000E Series | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
1 | FORTINET DOCUMENT LIBRARY
https://docs.fortinet.com
FORTINET VIDEO GUIDE
https://video.fortinet.com
FORTINET BLOG
https://blog.fortinet.com
CUSTOMER SERVICE & SUPPORT
https://support.fortinet.com
FORTINET TRAINING & CERTIFICATION PROGRAM
https://www.fortinet.com/support-and-training/training.html
NSE INSTITUTE
https://... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
2 | TABLE OF CONTENTS
Change log 6
FortiGate-7060E chassis 7
FortiGate-7060E front panel 7
FIM modules 8
FPM-7620E 9
FPM-7630E 9
FortiGate-7060E back panel 9
Power consumption for different FortiGate-7060E configurations 10
Power consumption calculation with four FPM-7620Es 11
Power consumption calculation with four FPM-76... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
3 | Fortinet Technologies Inc.
Getting started with FortiGate-7060E 31
Multi VDOM mode 32
Confirming startup status 32
Setting up management connections 33
Setting up a single management connection 34
Setting up redundant management connections 34
Adding a password to the admin administrator account 36
Changing data interf... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
4 | Fortinet Technologies Inc.
Regulatory notices 66
Federal Communication Commission (FCC) – USA 66
Industry Canada Equipment Standard for Digital Equipment (ICES) – Canada 66
European Conformity (CE) - EU 66
Voluntary Control Council for Interference (VCCI) – Japan 67
Product Safety Electrical Appliance & Material (PSE) ... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
5 | Change log
Date Change description
May 12, 2022 New section: Agência Nacional de Telecomunicações (ANATEL) – Brazil on page 68.
January 4, 2021 Added more information about using and retaining the FIM and FPM blank panels to
FortiGate-7060E front panel on page 7 and Chassis hardware information on page 13.
Added the FP... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
6 | FortiGate-7060E chassis
The FortiGate-7060E is a 8U 19-inch rackmount 6-slot chassis with a 80Gbps fabric and 1Gbps base backplane
designed by Fortinet. The fabric backplane provides network data communication and the base backplane provides
management and synch communication among the chassis slots.
FortiGate-7060E fr... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
7 | FortiGate-7060E chassis Fortinet Technologies Inc.
Do not operate the FortiGate-7060E chassis with open slots on the front or back panel. For
optimum cooling performance and safety, chassis front panel slots 1 and 2 must contain FIMs.
Front panel slots 3 to 12 must contain FPMs or FPM blank panels (also called dummy ca... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
8 | FortiGate-7060E chassis Fortinet Technologies Inc.
FPM-7620E
The FPM-7620E is a hot swappable processor module that provides FortiOS firewalling and security services. FPMs in
the chassis function as workers, processing sessions load balanced to them by the FIMs. FPMs include multiple NP6
network processors and CP9 con... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
9 | FortiGate-7060E chassis Fortinet Technologies Inc.
FortiGate-7060E back panel
Fan Tray 3 Fan Tray 2 Fan Tray 1
Chassis
Ground
Connector
Power consumption for different FortiGate-7060E configurations
The tables in this section provide information about how to calculate average and maximum power consumption for a
FortiGa... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
10 | FortiGate-7060E chassis Fortinet Technologies Inc.
Power consumption calculation with four FPM-7620Es
Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total
average
power (W)
Max power
(W)
FPM-7620E 320 410 4 1280 1640
FIM-7901E 260 450 2 520 900
Fan trays and
SMMs
530 737 N/A 530 737
To... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
11 | FortiGate-7060E chassis Fortinet Technologies Inc.
Power consumption calculation with two FPM-7630Es
Module Average power
consumption (W)
Max power
consumption (W)
Number of
modules
Total
average
power (W)
Max power
(W)
FPM-7630E 340 440 2 680 880
FIM-7901E 260 450 2 520 900
Fan trays and
SMMs
530 737 N/A 530 737
Total... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
12 | FortiGate-7060E chassis Fortinet Technologies Inc.
IPMB
SERIAL
IPMB
SERIAL
IPMB
SERIAL
IPMB
NP6 CP9 SERIAL
NP6 CP9 SMC SDI
DP2 ISF
DP2 ISF
IPMB
SERIAL
1G
SMC SDI SMC SDI
MGMT1 (inactive by default, IPMB 0x22) MGMT2 (active by default, IPMB 0x20)
FPM
FIM
FIM
FPM
FPM3 IPMB 0x86
IPMB
NP6 CP9 SMC SDI SERIAL
FPM FPM5 IPMB 0... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
13 | FortiGate-7060E chassis Fortinet Technologies Inc.
Shipping components
The FortiGate-7060E chassis ships pre-assembled with the following components:
l The 8U FortiGate-7060E chassis.
l Two FIM modules.
l Up to four FPM modules.
l Two System Management Modules (SMMs) in the front of the chassis. (SMMs are not field rep... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
14 | FortiGate-7060E chassis Fortinet Technologies Inc.
The following optional accessories can be ordered separately:
l Additional FIM and FPM modules
l Transceivers
l DC PSUs
l Additional AC PSUs
l Additional FAN trays
l Air Filter kit
l FPM and FIM blank panels to be installed in empty chassis slots
Physical description o... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |
15 | FortiGate-7060E chassis Fortinet Technologies Inc.
Cooling fans, cooling air flow, and minimum clearance
The FortiGate-7060E chassis contains three hot swappable cooling fan trays installed in the back of the chassis. Each
fan tray includes two fans that operate together. When the fan tray LED is green, both fans are o... | https://fortinetweb.s3.amazonaws.com/docs.fortinet.com/v2/attachments/5bada950-1a11-11e9-9685-f8bc1258b856/fortigate-7060E-system-guide.pdf |