robohand-data / README.md
Ever2after's picture
Dataset card: 2026-11-20 surgical-skill sessions
d2ce48d verified
|
Raw History Blame Contribute Delete
9.11 kB
metadata
pretty_name: Robohand multi-view RGB-D hand capture
tags:
  - rgb-d
  - depth
  - multi-view
  - hand
  - realsense
  - data-glove
  - surgical-skills
  - suturing
size_categories:
  - n<1K

Robohand multi-view RGB-D hand capture

Raw sessions recorded with Robohand. The dataset has two parts:

  • 2026-11-17 sessions. Three Intel RealSense D405 cameras (colour + colour-aligned depth) on a shared host clock. One session also has a MANUS data glove.
  • 2026-11-20 surgical-skill sessions. The same three D405s plus four 4K RGB webcams (OBSBOT Tiny 2 Lite). There are 36 takes of three tasks on a silicone suture pad, filed by task.

The ChArUco extrinsic calibrations used for the multi-camera point cloud are included.

The data is the unprocessed output of the capture tool. There are no annotations beyond the task folders, and no train/test split.

Layout

calibration.json                     # calibration that was active at the end of the last session
recordings/
  <YYYYMMDD_HHMMSS_us>/              # 2026-11-17 sessions (D405 only)
  01_suturing/<session>/             # 2026-11-20, task 1: needle suturing (바늘 봉합)
  02_incision/<session>/             # 2026-11-20, task 2: scalpel incision (절개)
  03_needle_holder/<session>/        # 2026-11-20, task 3: needle-holder handling (니들홀더 결합)

<session>/
  session.json                       # devices, intrinsics, per-track stats, webcam stats, timing notes
  calibration.json                   # (2026-11-20) copy of the calibration active at record start
  d405{,_2,_3}_color.mp4             # H.264, 640x480, 30 fps timeline
  d405{,_2,_3}_depth.mp4             # colourised depth preview (lossy, display only)
  d405{,_2,_3}_depth_raw.mkv         # lossless FFV1 uint16 depth, aligned to the colour image
  d405{,_2,_3}_*_timestamps.csv      # per-output-frame host timestamps and repeat flags
  rgb4k_{1..4}.mkv                   # (2026-11-20) 3840x2160 MJPEG, the camera's own JPEGs, untouched
  rgb4k_{1..4}_timestamps.csv        # (2026-11-20) per-frame host / device timestamps
  *_encoder.log                      # ffmpeg logs (2026-11-17 only; empty logs are omitted)
  manus.jsonl                        # (one 2026-11-17 session) MANUS glove data
calibrations/
  checkerboard_<timestamp>/          # one ChArUco extrinsic calibration run
    calibration.json                 # result: per-camera T_board_from_camera, board size, residuals
    calibration_previous.json        # the calibration it replaced
    highres/frame_XXX/               # captured colour + depth (.png / .npy) per camera
    overlays/                        # detection overlays
  depth_scale_<timestamp>/           # board-scale fit against D405 depth (earlier board estimate)

2026-11-20 surgical-skill sessions

One operator, seated, working on a silicone suture pad placed on the ChArUco board. Each task was recorded as about ten consecutive takes. The task labels come from the operator's instruction and a visual check of every take.

Task Folder Takes Duration per take What happens
1. Needle suturing (바늘 봉합) recordings/01_suturing 12 25–46 s (first take 113 s) Needle holder + forceps, a stitch through the pad
2. Incision (절개) recordings/02_incision 13 5–9 s Scalpel cut along a line on the pad (pad rotated 90°)
3. Needle-holder handling (니들홀더 결합) recordings/03_needle_holder 11 7–12 s Needle holder + forceps working together on the needle
Folder Sessions
01_suturing 20261120_131200_031491, 131401_475082, 131436_383395, 131521_681330, 131555_988990, 131635_896989, 131709_828736, 131743_182533, 131813_212182, 131924_237058, 132000_853526, 132040_378256
02_incision 20261120_132315_763254, 132331_273600, 132340_885499, 132349_263904, 132357_256319, 132403_860588, 132411_355751, 132419_118078, 132425_900062, 132434_890579, 132441_838439, 132448_103399, 132501_787405
03_needle_holder 20261120_132604_217436, 132619_652182, 132631_612320, 132646_622626, 132701_658489, 132715_878807, 132726_847798, 132741_881376, 132753_407323, 132804_141430, 132814_944405

All 36 takes were recorded with the same camera placement and the calibration checkerboard_20261120_130857. A copy of it is in every session folder.

Cameras.

  • 3 × D405 at 640x480, 15 fps capture, written to a 30 fps timeline.
  • 4 × 4K webcam at 3840x2160, requested at 30 fps. The webcams record their native frame timing, with no repeats.
    • rgb4k_1 and rgb4k_2 run at 30 fps.
    • rgb4k_3 and rgb4k_4 run at about 21 and 24 fps. They shared a USB controller during capture.

Webcam poses are not included. The calibration contains extrinsics for the three D405s only. The webcams had no lens (intrinsic) calibration yet, so they are listed under failed_cameras in calibration.json. Use the webcam videos as additional 2D views.

2026-11-17 sessions

All sessions: 3 x D405 at 640x480, 15 fps capture, written to a 30 fps timeline (frames repeated when no new sample arrived; see repeated_frames in session.json).

Session Duration Extra streams Calibration in use (inferred from timestamps)
20261117_134147_822622 24 s - checkerboard_20261116_222942
20261117_141513_950731 103 s - checkerboard_20261117_140852
20261117_142147_402231 102 s - checkerboard_20261117_142035
20261117_143224_555777 95 s - checkerboard_20261117_142035
20261117_143843_991204 137 s MANUS glove (both hands) checkerboard_20261117_142035
20261117_144553_427534 26 s - checkerboard_20261117_144446

These sessions do not record which calibration was active. The last column is the most recent calibration written before the session started.

Formats

Depth. *_depth_raw.mkv holds uint16 frames (FFV1, gray16le). Metric depth in metres is value * devices[camera_key].depth_scale_m (1e-4 for the D405). The values 0 and 65535 mean no depth. Depth is aligned to the colour camera, so use the color_intrinsics from session.json for both.

import imageio_ffmpeg, numpy as np
reader = imageio_ffmpeg.read_frames("d405_depth_raw.mkv", pix_fmt="gray16le")
meta = next(reader)
depth = np.frombuffer(next(reader), np.uint16).reshape(480, 640)   # first frame

4K webcams (rgb4k_N.mkv). MJPEG in Matroska. Each packet is the JPEG the camera sent, copied without re-encoding. Packet timestamps are milliseconds on the session clock. rgb4k_N_timestamps.csv has these columns:

  • frame
  • t_host_s: host arrival time, seconds from start_monotonic_s
  • t_device_s: DirectShow timestamp
  • bytes

session.json > webcams > cameras lists the frame count, mean fps and device info.

import av
with av.open("rgb4k_1.mkv") as container:
    for frame in container.decode(video=0):
        image = frame.to_ndarray(format="bgr24")    # 2160x3840x3

Timing. Every stream uses the host time.monotonic() clock. start_monotonic_s in session.json is the zero point. The cameras are not hardware-synchronised. Each 30 fps D405 output frame carries the newest sample available at that time.

MANUS glove (manus.jsonl).

  • The first line is a header ("type": "header"). It defines:
    • the ergonomics angle names
    • the skeleton node tree (skeleton_nodes: id, parent, finger chain and joint for each hand)
    • the array layouts
  • Each following line has:
    • a stream:
      • ergonomics: 40 joint angles in degrees
      • skeleton: 25 nodes as [id, px, py, pz, qw, qx, qy, qz]
      • raw: sensor and IMU poses
    • a gloves list
    • t_host_s, relative to start_monotonic_s
    • publish_utc_ms: the MANUS Core publish time, 1 ms resolution
  • Coordinates follow the MANUS VUH convention: X from the viewer, Z up, right-handed, metres.
  • The glove IDs map to left/right in session.json > manus > glove_sides.

Calibration. The board is ChArUco, 7 x 5 squares, DICT_6X6_250, with marker = square x 18/25. The board frame has X along the columns, Y opposite to the rows and Z up, in metres. Each camera has T_board_from_camera (4x4) and T_camera_from_board. Cameras are matched by serial.

Loading with Robohand

git clone https://github.com/Ever2after/robohand && cd robohand && setup.cmd
set ROBOHAND_DATA=<path to this dataset>
"Depth Replay 3D.cmd"

The replay tool overlays the three D405 point clouds in the board frame. For the glove session it also draws the hand skeleton.

Opening a session. The tool's session list shows recordings/<session> only. Open a take inside a task folder with the folder picker.

Which calibration is used. The tool uses the calibration that was in effect at record time:

  • 2026-11-20 sessions have their own calibration.json copy, and the tool uses it.
  • 2026-11-17 sessions have no copy. The tool picks the newest calibrations/*/calibration.json created before the session started (see the 2026-11-17 table).