text
stringlengths
0
99.6k
By Ward Christensen 1/1/82
I will maintain a master copy of this.
Please pass on changes or suggestions
via CBBS/Chicago at (312) 545-8086,
CBBS/CPMUG (312) 849-1132 or by voice
at (312) 849-6279.
Last Revision: 6/18/85 By Henry C.
Schmitt.---State Table Appendix.
Previous Revisions: 1/13/85 By John
Byrns.---CRC Option Addendum.
8/9/82 By Ward Christensen.---Change
ACK to 06H (from 05H).
This version of the document was
downloaded from the CBBS/CPMUG on
6/13/85 and the addition of the
revision marks (') and minor
editorial changes were made by Henry
C. Schmitt. Many people ask me for
documentation on my modem protocol,
i.e. the one used in the various
modem programs in CPMUG, on volumes 6,
25, 40, 47... so here it is. At the
request of Rick Mallinak on behalf of
the guys at Standard Oil with IBM
P.C.s, as well as several previous
requests, I finally decided to put my
modem protocol into writing. It had
been previously formally published
only in the AMRAD newsletter.
Table of Contents
1. DEFINITIONS
2. TRANSMISSION MEDIUM LEVEL PROTOCOL
3. MESSAGE BLOCK LEVEL PROTOCOL
4. FILE LEVEL PROTOCOL
5. DATA FLOW EXAMPLE INCLUDING ERROR
RECOVERY
6. PROGRAMMING TIPS.
7. OVERVIEW OF CRC OPTION
8. MESSAGE BLOCK LEVEL PROTOCOL, CRC
MODE
9. CRC CALCULATION
10. FILE LEVEL PROTOCOL, CHANGES FOR
COMPATIBILITY
11. DATA FLOW EXAMPLES WITH CRC OPTION
Appendix 1. MODEM PROTOCOL STATE
TABLE
1. DEFINITIONS. <SOH> 01H <EOT>
04H <ACK> 06H <NAK> 15H
<CAN> 18H <C> 43H
2. TRANSMISSION MEDIUM LEVEL PROTOCOL
Asynchronous, 8 data bits, no parity,
one stop bit.
The protocol imposes no restrictions on
the contents of the data being
transmitted. No control characters
are looked for in the 128-byte data
messages. Absolutely any kind of data
may be sent - binary, ASCII, etc. The
protocol has not formally been adopted
to a 7-bit environment for the
transmission of ASCII-only (or
unpacked-hex) data, although it could
be simply by having both ends agree to
AND the protocol-dependent data with 7F
hex before validating it. I
specifically am referring to the
checksum, and the block numbers and
their ones-complement.
Those wishing to maintain compatibility
of the CP/M file structure, i.e., to
allow modemming ASCII files to or from
CP/M systems should follow this data
format:
* ASCII tabs used (09H); tabs set
every 8.
* Lines terminated by CR/LF (0DH 0AH)
* End-of-file indicated by ^Z, 1AH.
(one or more)
* Data is variable length, i.e. should
be considered a continuous stream
of data bytes, broken into 128-byte
chunks purely for the purpose of
transmission.
* A CP/M "peculiarity": If the data
ends exactly on a 128-byte boundary,
i.e.,
CR in 127, and LF in 128, a
subsequent sector containing the ^Z EOF
character(s) is optional, but is
preferred. Some utilities or user
prgrams