hash
stringlengths
32
32
doc_id
stringlengths
5
12
section
stringlengths
5
1.47k
content
stringlengths
0
6.67M
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.1.2.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.1.2.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.1.2.2.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.1.2.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.2.4.2 with following exceptions: - Table 6.7.1.1.2.5-1 is replaced by Table 19.6.1.2.2.5-1. - Table 6.7.1.1.2.5-2 is replaced by Table 6.7.1.2.2.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.1.2.2.4.3 Message contents
Same as the message contents given in clause 6.7.1.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.1.2.2.5 Test requirement
Same as the test requirements given in clause 6.7.1.2.2.5 with following exceptions: - Table 6.7.1.2.2.5-1 is replaced by Table Table 19.6.1.2.2.5-1. Table 19.6.1.2.2.5-1: NR Cell specific test parameters (same as Table 6.7.1.2.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Cell 1 Cell...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2 SS-RSRQ for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.0.1 Intra-frequency SS-RSRQ measurement accuracy requirements
Same as in clause 4.7.2.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.0.2 Inter-frequency SS-RSRQ absolute measurement accuracy requirements
Same as in clause 4.7.2.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.0.3 Inter-frequency SS-RSRQ relative measurement accuracy requirements
Same as in clause 4.7.2.0.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1 NR SA FR1 SS-RSRQ absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-RSRQ measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.2.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.2.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.2.1.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table 6....
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.2.1.4.2 with following exceptions: - Table 6.7.2.1.5-1 is replaced by Table 19.6.2.1.5-1; - Table 6.7.2.1.5-2 is replaced by Table 19.6.2.1.5-2;
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.4.3 Message contents
Same as the message contents given in clause 6.7.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.1.5 Test requirement
Same as the test requirements given in clause 6.7.2.1.5 with following exceptions: - Table 6.7.2.1.5-1 is replaced by Table 19.6.2.1.5-1; Table 19.6.2.1.5-1: NR Cell specific test parameters (Same as Table 6.7.2.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Test 3 Cell 1 Cell 2 Cell 1...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2 Inter-frequency SS-RSRQ measurements for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1 NR SA FR1-FR1 SS-RSRQ absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRQ absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.1.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.2.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.2.2.1.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.2.1.1.4.2 with following exceptions: - Table 6.7.2.1.1.5-1 is replaced by Table 19.6.2.2.1.5-1. - Table 6.7.2.1.1.5-2 is replaced by Table 6.7.2.2.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.4.3 Message contents
Same as the message contents given in clause 6.7.2.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.1.5 Test requirement
Same as the test requirements given in clause 6.7.2.2.1.5 with following exceptions: - Table 6.7.2.2.1.5-1 is replaced by Table 19.6.2.2.1.5-1. Table 19.6.2.2.1.5-1: NR Cell specific test parameters (Same as Table 6.7.2.2.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Test 3 Cell 1 Cel...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2 NR SA FR1-FR1 SS-RSRQ relative measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.1.0.4. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.1.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.2.2.2.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.1.1.2.4.2 with following exceptions: - Table 6.7.2.2.2.5-1 is replaced by Table 19.6.2.2.2.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.4.3 Message contents
Same as the message contents given in clause 6.7.2.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.2.2.2.5 Test requirement
Same as the test requirements given in clause 6.7.2.2.2.5 with following exceptions: - Table 6.7.2.2.2.5-1 is replaced by Table 19.6.2.2.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3 SS-SINR for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.0.1 Intra-frequency SS-SINR measurement accuracy requirements
Same as in clause 4.7.3.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.0.2 Inter-frequency SS-SINR absolute measurement accuracy requirements
Same as in clause 4.7.3.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.0.3 Inter-frequency SS-SINR relative measurement accuracy requirements
Same as in clause 4.7.3.0.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1 NR SA FR1 SS-SINR absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.1 Test purpose
The purpose of this test is to verify that the intra-frequency SS-SINR measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards and supporting ss-SINR-Meas.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.3.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.3.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.3.1.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table 6....
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.3.1.4.2 with following exceptions: - Table 6.7.3.1.5-1 is replaced by Table 19.6.3.1.5-1;
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.4.3 Message contents
Same as the message contents given in clause 6.7.3.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.1.5 Test requirement
Same as the test requirements given in clause 6.7.3.1.5 with following exceptions: - Table 6.7.3.1.5-1 is replaced by Table 19.6.3.1.5-1; Table 19.6.3.1.5-1: NR Cell specific test parameters (Same as Table 6.7.3.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Cell 1 Cell 2 Cell 1 Cell 2...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2 Inter-frequency SS-SINR measurements for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1 NR SA FR1-FR1 SS-SINR absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-SINR absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards and supporting ss-SINR-Meas.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.1.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.3.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.3.2.1.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.3.1.4.2 with following exceptions: - Table 6.7.3.1.5-1 is replaced by Table 19.6.3.2.1.5-1. - Table 6.7.3.1.5-2 is replaced by Table 6.7.3.2.1.5-2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.4.3 Message contents
Same as the message contents given in clause 6.7.3.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.1.5 Test requirement
Same as the test requirements given in clause 6.7.3.2.1.5 with following exceptions: - Table 6.7.3.2.1.5-1 is replaced by Table 19.6.3.2.1.5-1. Table 19.6.3.2.1.5-1: NR Cell specific test parameters (Same as Table 6.7.3.2.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Test 3 Cell 1 Cel...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2 NR SA FR1-FR1 SS-SINR relative measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.1 Test purpose
The purpose of this test is to verify that the inter-frequency SS-SINR relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards and supporting ss-SINR-meas.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.1.0.3. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.1.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.4.1 Initial conditions
Same as the initial conditions given in clause 6.7.3.2.2.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.3.2.2.4.2 with following exceptions: - Table 6.7.3.2.2.5-1 is replaced by Table 19.6.2.2.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.4.3 Message contents
Same as the message contents given in clause 6.7.3.2.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.3.2.2.5 Test requirement
Same as the test requirements given in clause 6.7.3.2.2.5 with following exceptions: - Table 6.7.3.2.2.5-1 is replaced by Table 19.6.2.2.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4 L1-RSRP measurement for beam reporting for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.0 Minimum conformance requirements
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.0.1 SSB based absolute L1-RSRP measurement accuracy requirements
Same as 4.7.4.0.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.0.2 SSB based relative L1-RSRP measurement accuracy requirements
Same as 4.7.4.0.2.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.0.3 CSI-RS based absolute L1-RSRP measurement accuracy requirements
Same as 4.7.4.0.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.0.4 CSI-RS based relative L1-RSRP measurement accuracy requirements
Same as 4.7.4.0.4.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1 SSB based L1-RSRP measurements for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1 NR SA FR1 SSB based L1-RSRP absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.1 Test purpose
The purpose of this test is to verify that the SSB based L1-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.4.0.1. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.4.1 Initial conditions
Same as the Initial conditions given in clause 6.7.4.1.1.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. - Table ...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.4.2 Test procedure
Same as the test procedure given in clause 6.7.4.1.1.4.2 with the following exceptions: - Table 6.7.4.1.1.5-1 is replaced by Table 19.6.4.1.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.4.3 Message contents
Same as the message contents given in clause 6.7.4.1.1.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.1.5 Test requirement
Same as the test requirements given in clause 6.7.4.1.1.5 with following exceptions: - Table 6.7.4.1.1.5-1 is replaced by Table 19.6.4.1.1.5-1. Table 19.6.4.1.1.5-1: NR Cell specific test parameters (Same as Table 6.7.4.1.1.5-1 with following exceptions) Parameter Test configuration Unit Test 1 Test 2 Propagation Condi...
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2 NR SA FR1 SSB based L1-RSRP relative measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.1 Test purpose
The purpose of this test is to verify that the SSB based L1-RSRP relative measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.3 Minimum conformance requirements
The minimum conformance requirements are specified in clause 19.6.4.0.2. The normative reference for this requirement is TS 38.133 [6] clause A.19.6.4.1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.4 Test description
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.4.1 Initial conditions
Same as the Initial conditions given in clause 6.7.4.1.2.4.1 with following exceptions: - During the test, UE positioning and UE speed are set by AT command. UE speed is 0km/h, UE specific positioning is emulated by test system. - During the test, the specific gNB reference location is emulated by test system. Table 6....
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.4.2 Test procedure
Same as the test procedure given in clause 6.7.4.1.2.4.2 with following exceptions: - Table 6.7.4.1.2.5-1 is replaced by Table 19.6.4.1.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.4.3 Message contents
Same as the message contents given in clause 6.7.4.1.2.4.3.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.1.2.5 Test requirement
Same as the test requirements given in clause 6.7.4.1.2.5 with following exceptions: - Table 6.7.4.1.2.5-1 is replaced by Table 19.6.4.1.1.5-1.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.2 CSI-RS based L1-RSRP measurements for ATG
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.2.1 NR SA FR1 CSI-RS based L1-RSRP absolute measurement accuracy for ATG
Editor’s Note: This test case is incomplete in following aspect: - TT analysis is still missing.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.2.1.1 Test purpose
The purpose of this test is to verify that the CSI-RS based L1-RSRP absolute measurement accuracy is within the specified limits for all bands.
f6aa351f9dfcf54f60d7745530e70f1e
38.533
19.6.4.2.1.2 Test applicability
This test applies to all types of NR ATG UE from Release 18 onwards.