Datasets:
Formats:
csv
Languages:
English
Size:
< 1K
Tags:
quantum-control
quantum-noise-spectroscopy
non-gaussian-noise
identifiability
boolean-fourier-analysis
robust-prediction
|
Download research/protocols/LAB_PROTOCOL.md from PureOne/EIROQ-PHI: direct link, hf CLI and curl.
- Browser
- Download file 2.61 kB
-
https://huggingface.co/datasets/PureOne/EIROQ-PHI/resolve/main/research/protocols/LAB_PROTOCOL.md
- Command line
-
hf download hf://datasets/PureOne/EIROQ-PHI/research/protocols/LAB_PROTOCOL.md
-
curl -L -o LAB_PROTOCOL.md https://huggingface.co/datasets/PureOne/EIROQ-PHI/resolve/main/research/protocols/LAB_PROTOCOL.md
2.61 kB
| # Preregisterable mechanism and decision validation | |
| ## Scope | |
| Single-qubit pure dephasing with independently calibrated binary integrated phase | |
| magnitudes. No claim that arbitrary natural noise has this support. Every prefix | |
| must use the marginal of a common environmental preparation law. | |
| ## Protocol A: expose the hidden direction | |
| Freeze the seven-bin fourth-order sign laws p_plus and p_minus, common amplitudes, | |
| all prefix controls with at most two pulses, and the three-pulse target cuts | |
| (1,3,5). Calibrate phase magnitude, pulse width/error, relaxation, state preparation, | |
| and readout independently. Generate the sign histories from the released exact | |
| law, not by fitting the acquired data. Interleave the laws and measurement settings | |
| where the preparation protocol permits it. Log chronology and all failures. | |
| Primary predictions: low-pulse responses agree within the propagated error budget; | |
| the target contrast follows the exact response product. Scan a common amplitude | |
| as a control: the low-pulse difference stays zero in the ideal model. Add a local | |
| pair amplitude imbalance to test the explicit capability tradeoff. Distinguish | |
| phase error from a failure of the hypothesized common law. | |
| ## Protocol B: certify before measuring the target | |
| Use six bins at independently validated phase magnitude pi/4. Acquire prefixes | |
| (2,()), (4,(1,)), (6,(1,3)) and baseline (6,()). Freeze the simultaneous confidence | |
| rule and systematic allowances. Publish the target lower bound and paired gain | |
| before measuring target (6,(1,3,5)). The target data are validation, not selection | |
| input. Include the extra target pulse's independent error allowance. | |
| ## Baselines and costs | |
| Compare a direct target/baseline scan, the proposed prefix certificate, and an | |
| appropriate established control-adapted method under matched support priors, | |
| confidence, number of shots, readout, pulse imperfections, reset costs, and target | |
| fidelity. Record total duration and required host processing. Do not substitute | |
| settings for shots or ideal pulse counts for total time. | |
| ## Failure conditions | |
| Reject the device-model claim if the calibrated model cannot jointly explain | |
| prefix, baseline, and held-out target data. Reject a confidence claim if coverage | |
| violations exceed the preregistered combined statistical/systematic budget. Reject | |
| an efficiency claim if its gain disappears against a real matched competitor. | |
| Empty feasible sets produce an abstention and diagnosis, not a favorable fitted | |
| law. No sample size is universally prescribed; the supplied synthetic 50,000-shot | |
| example is not a laboratory power calculation. | |