|
Download cases/case06/task.md from Tauben/PhysClosureBench: direct link, hf CLI and curl.
- Browser
- Download file 6.11 kB
-
https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case06/task.md
- Command line
-
hf download hf://datasets/Tauben/PhysClosureBench/cases/case06/task.md
-
curl -L -o task.md https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case06/task.md
6.11 kB
| # Causal time-domain inference in a driven three-state system | |
| ## Background | |
| Attosecond transient-absorption spectra can encode the causal electronic | |
| response of a laser-dressed system. Recovering the corresponding motion in the | |
| time domain would make the spectrum a direct probe of ultrafast dynamics, but | |
| an experimental attosecond probe has a finite duration rather than the ideal | |
| impulsive form often assumed in such an interpretation. | |
| ## Research problem | |
| Develop and assess a reproducible procedure, within causal linear-response | |
| theory, for recovering the time-dependent dipole motion of the infrared-dressed | |
| system below from its transient-absorption signal. Determine how faithfully the | |
| relevant motion can be recovered for attosecond-probe durations of 100, 300 and | |
| 500 as, why the finite probe matters, and what physical claim is supported by | |
| the calculated evidence. | |
| The derivation, numerical realization, signal processing, diagnostic design, | |
| choice of figures and structure of the scientific argument are yours. Assess | |
| the reconstruction from computed evidence rather than assuming that it works. | |
| ## Physical inputs | |
| Use atomic units for the dynamical calculation. The model contains a ground | |
| state $|g\rangle$, a dipole-allowed excited state $|a\rangle$ and an | |
| infrared-coupled state $|f\rangle$. The only nonzero transition dipoles in the | |
| model are | |
| $$ | |
| \mu_{ga}=0.34,\qquad \mu_{af}=2.72, | |
| $$ | |
| with energy differences | |
| $$ | |
| E_a-E_g=21.057\ \mathrm{eV},\qquad E_f-E_a=-0.82\ \mathrm{eV}. | |
| $$ | |
| The system is initially in $|g\rangle$ before either field is appreciable. | |
| Use electric-dipole coupling and the following linearly polarized fields. The | |
| attosecond probe is | |
| $$ | |
| E_X(t)=E_{X0}e^{-\lambda |t|}\cos(\omega_X t), | |
| \qquad \tau_X=\frac{2\ln 2}{\lambda}, | |
| $$ | |
| with photon energy $21\ \mathrm{eV}$, peak intensity | |
| $10^{10}\ \mathrm{W\,cm^{-2}}$, and $\tau_X=100$, 300 or 500 as. Define the | |
| probe centre as $t=0$. | |
| The infrared field is | |
| $$ | |
| E_{\mathrm{IR}}(t,\tau)=E_0 A(t-\tau) | |
| \cos[\omega_{\mathrm{IR}}(t-\tau)], | |
| $$ | |
| where | |
| $$ | |
| A(u)= | |
| \begin{cases} | |
| \cos^2\!\left(\dfrac{\omega_{\mathrm{IR}}u}{2N}\right), | |
| & |u|\le N\pi/\omega_{\mathrm{IR}},\\[4pt] | |
| 0,&\text{otherwise}, | |
| \end{cases} | |
| $$ | |
| $N=10$, $\hbar\omega_{\mathrm{IR}}=0.82\ \mathrm{eV}$ and the peak intensity | |
| is $5\ \mathrm{TW\,cm^{-2}}$. Set the infrared-pulse centre five infrared | |
| optical cycles after the probe centre. Obtain field amplitudes from a standard, | |
| consistently reported intensity conversion. | |
| For this task, the source-model decoherence is imposed by the following | |
| author-supplied policy. First solve the driven three-state problem and obtain | |
| its physical real dipole $d_0(t)$. Then define | |
| $$ | |
| d_{\mathrm{phys}}(t)= | |
| \begin{cases} | |
| d_0(t),&t\le 0,\\ | |
| d_0(t)e^{-t/(50\ \mathrm{fs})},&t>0. | |
| \end{cases} | |
| $$ | |
| Apply this operation before constructing the absorption signal. Do not put it | |
| in the Hamiltonian, reinterpret it as population or amplitude damping, or | |
| apply an additional Fourier apodization window. | |
| State the time, frequency, Fourier-sign, dipole-sign and display conventions | |
| used in your work. Absolute arbitrary-unit vertical scale is not a grading | |
| target. | |
| ## Method and scope | |
| Use the standard three-level time-dependent Schrödinger equation for the | |
| stated couplings and a causal linear-response or Kramers-Kronig reconstruction | |
| from the positive-frequency transient-absorption signal. You may choose and | |
| cite standard formulations consistent with these method families. Do not add | |
| levels, ionization channels or nonlinear probe response to the graded model. | |
| All numerical choices not fixed above are yours. Check that the reported | |
| signals are sufficiently reliable and reproducible to support your claim; no | |
| particular grid, record length, propagator, transform algorithm, regularizer, | |
| comparison metric or refinement sequence is prescribed. | |
| ## Submission | |
| Submit one self-contained scientific report and an offline reproduction | |
| package. The report must answer the research question from your calculated | |
| time-dependent reconstruction and must contain enough quantitative evidence | |
| to audit every probe-duration-dependent claim. The selection and organization | |
| of that evidence are yours. | |
| Include a provenance note listing every offline source or software document actually consulted and the method basis for items supplied from general knowledge. | |
| Include the derivation actually used, source code, an executable command or | |
| script, machine-readable data underlying the reported evidence, plotting or | |
| analysis code, references, and concise run and environment information. No | |
| fixed file tree, filename scheme, complete exploratory history or | |
| examiner-selected intermediate plot is required. | |
| The active examination resources and limits are defined in the companion | |
| `resource_limits.json`. All retained production calculations must run | |
| within that fixed allocation and active wall time. More expensive modelling | |
| does not receive additional credit. | |
| ## Reference and integrity policy | |
| This examination is conducted without network access or live literature | |
| retrieval. You may rely on your existing general scientific knowledge and, if any are | |
| explicitly supplied with the examination, on those offline materials or | |
| software documentation. Record every such source actually consulted. For formulas, | |
| methods, constants, or conventions used from general knowledge rather than a | |
| consulted source, state enough of the method basis, definition, value, units, | |
| and convention to make the calculation auditable; do not invent a citation. | |
| You are not required to identify or prove a publication date or to retrieve | |
| literature during the examination. | |
| The hidden target article and its identifying metadata, figures or captions, | |
| supplementary material, author code or data, target-specific reproduction | |
| code, solution or scoring material, online solutions, and worked | |
| reproductions of this case must not be used. All submitted scientific figures | |
| and numerical data must be generated by your own implementation of the stated | |
| problem. | |
| See [submission requirements](../../submission_requirements.md) for the common submission entry points. | |