Download cases/case38/task.md from Tauben/PhysClosureBench: direct link, hf CLI and curl.
- Browser
- Download file 5.05 kB
-
https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case38/task.md
- Command line
-
hf download hf://datasets/Tauben/PhysClosureBench/cases/case38/task.md
-
curl -L -o task.md https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case38/task.md
Valley-resolved and Brillouin-zone-integrated topological high-harmonic emission
Physical setting
Work in atomic units. Consider a two-band Haldane model on a hexagonal lattice with two sites per unit cell. Let
and
where
Use the Bloch Hamiltonian
with
The shared parameters are
Compare two physical cases, $t_2=-0.0013i$ and $t_2=-0.0087i$. Drive the system along the $\Gamma$-$M$ direction through the Peierls shift $\mathbf k\mapsto\mathbf k+\mathbf A(t)$, with
and $\mathbf A(t)=0$ outside the pulse. Use $A_0=0.1$, $\omega=0.0075$, and $n_{\mathrm{cyc}}=5$.
Treat the driven crystal within independent-electron dynamics of this two-band Bloch Hamiltonian, starting from its lower band. Characterize the emitted high-harmonic field through its complex components parallel and perpendicular to the driver. Use one consistent Fourier convention and a common normalization; absolute spectral intensity is not a grading target.
Research problem
Determine whether and how the change between the two Haldane-model cases affects the polarization and helicity of high-harmonic emission, and establish the relation between the valley-resolved response at the inequivalent $K$ and $K'$ points and the observable response of a completely occupied lower band.
Use your computed harmonic yields and complex channel phases to decide whether the valley response follows one common rule at both valleys. Determine whether any polarization information remains in the integrated response, and state what that observable can and cannot establish about its microscopic crystal-momentum origin. Limit all conclusions to the bulk, independent-electron, two-band model specified above.
Your evidence must keep the two model cases, the $K$ and $K'$ initial states, the fixed-valley and filled-band calculations, and the two response directions unambiguous. The derivation, numerical representation, Brillouin-zone sampling, propagator, time step, differentiation and Fourier procedures, treatment of weak components, reliability strategy, normalization, plotting choices, and report organization are for you to decide and justify. No particular number, order, or layout of figures is prescribed.
Submission and resources
Submit one self-contained scientific report and an auditable offline calculation package containing the task-specific derivation, code, numerical data underlying all material claims, a provenance note listing every offline source or software document actually consulted and the method basis for items supplied from general knowledge, and concise run and environment information. No fixed file tree, filename scheme, panel count, or complete exploration history is required.
Resource limits are supplied exclusively by the accompanying
resource_limits.json. Its fixed CPU allocation, candidate-active
wall time, network boundary are binding. No separate aggregate CPU-hour limit applies. Greater computational expense
receives no additional credit.
Reference and integrity policy
Complete this task without network access or live literature retrieval. You may rely on your existing general scientific knowledge and, if any are explicitly supplied with this task, on those offline materials or software documentation. Record every such source actually consulted. For formulas, methods, constants, or conventions used from general knowledge rather than a consulted source, state enough of the method basis, definition, value, units, and convention to make the calculation auditable; do not invent a citation. You are not required to identify or prove a publication date or to retrieve literature while completing this task.
The hidden target article and its identifying metadata, figures or captions, supplementary material, author code or data, target-specific reproduction code, solution or scoring material, online solutions, and worked reproductions of this case must not be used. All submitted scientific figures and numerical data must be generated by your own implementation of the stated problem.
See submission requirements for the common submission entry points.