DRC errors in detailed routing - "Metal spacing violation"

Tool: Detailed Routing

Subcategory: DRC violation

Conversation

oharboe

I think this is happening because two macros that need straight vertical wires between them don't have IO pins lined up and then the wires between the macros are criss-crossing.

What is the difference and purpose of MACRO_PLACE_HALO vs MACRO_PLACE_CHANNEL and where do I use them, in the macro or where I'm using the macro from?

Some thoughts on what I might do:

  • I could modify the halo macro to have a big enough "halo" (black area) where the wires can move horizontally to line up better with their destination pin in the other macro.
  • I could fix the io pin locations and floorplan so the router is able to use straight vertical wires instead of crisscrossing between two macros. This would reduce the need for a big halo.

image

vijayank88

@oharboe Variable description found here: https://openroad-flow-scripts.readthedocs.io/en/latest/user/FlowVariables.html#floorplan

maliberty

Note that mpl distinguished halo vs channel but mpl2 just uses halo. The distinction is that a channel is the space between two macros but the halo applies on all sides of the macro.

I can't tell much from the picture.

maliberty

The setting are for x & y separately. Usually they are the same

maliberty

Imagine channel=10 and halo=5. Then macros must be 10 apart but standard cells must be 5 away from a macro. It is moot with mpl2.

oharboe

Updated docs in pull request based on the above: https://github.com/The-OpenROAD-Project/OpenROAD-flow-scripts/pull/1007