title: bench_wires(2)
date: 24/09/08
---
# NAME
bench_wires - bench wires
# SYNOPSIS
bench_wires
[-met_cnt mcnt]
[-cnt count]
[-len wire_len]
[-over]
[-diag]
[-all]
[-db_only]
[-under_met layer]
[-w_list width]
[-s_list space]
[-over_dist dist]
[-under_dist dist]
# DESCRIPTION
The `bench_wires` command produces a layout which contains various patterns
that are used to characterize per-unit length R and C values. The generated patterns model
the lateral, vertical, and diagonal coupling capacitances, as well as ground
capacitance effects. This command generates a .def file that contains a number of wire patterns.
This command is specifically intended for the Extraction Rules file generation only.
# OPTIONS
`-met_cnt`: Number of layers used in each pattern. The default value is `-1`, meaning it is not set, and the allowed values are integers `[0, MAX_INT]`.
`-cnt`: Number of wires in each pattern. The default value is `5`, and the default values are integers `[0, MAX_INT]`.
`-len`: Wirelength in microns in the pattern. The default value is `100`, and the allowed values are integers `[0, MAX_INT]`.
`-all`: Consider all different pattern geometries (`over`, `under`, `over_under`, and `diagonal`).
`-db_only`: Run with db values only. All parameters in `bench_wires` are ignored.
`-under_met`: Consider under metal layer.
`-w_list`: Lists of wire width multipliers from the minimum spacing defined in the LEF.
`-s_list`: Lists of wire spacing multipliers from the minimum spacing defined in the LEF. The list will be the input index on the OpenRCX RC table (Extraction Rules file).
`-over_dist, -under_dist`: Consider over and under metal distance respectively.
# ARGUMENTS
This command has no arguments.
# EXAMPLES
# SEE ALSO