"ToolName": "ノズルチェンジャー装着確認治具",
"Size": "",
"ToolOther": "FM-2902",
"WorkName": "シャッター動作確認",
"WorkItems": [
"1. シャッターの動作確認を行う"
],
"WorkPoints": [
" を㉖冶具(FM-2902)にセットする",
"シャッターをプッシュプルゲージで押して、開く時のストローク全域での最大荷重を測定する※この確認はあくまでの最終検査前の事前確認です",
"目安値: 4.2N 以下",
"最終検査はSD-A0147931-022にて実施"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"FM-2902"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2902",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "目安値4.2N以下",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "プッシュプルゲージ",
"Size": "",
"ToolOther": "",
"WorkName": "シャッター動作確認",
"WorkItems": [
"1. シャッターの動作確認を行う"
],
"WorkPoints": [
" を㉖冶具(FM-2902)にセットする",
"シャッターをプッシュプルゲージで押して、開く時のストローク全域での最大荷重を測定する※この確認はあくまでの最終検査前の事前確認です",
"目安値: 4.2N 以下",
"最終検査はSD-A0147931-022にて実施"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"FM-2902"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolCycle": "1回/1年",
"ToolRecord": "校正成績書",
"StdVal": "目安値4.2N以下",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "周辺部品取付",
"WorkItems": [
"◆1. にGUIDE をSPACER BOLT で取付ける"
],
"WorkPoints": [
"GUIDE の内側にグリースを塗布後、取付",
"GUIDE は右側に当付けて取付"
],
"Tolks": [
"締付トルク 95cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"グリース塗布 米粒:3"
]
}
|
{
"QualityItem": "塗布量",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "米粒:3",
"Method": "目視",
"RecordMethod": "-",
"Other": "グリースLCG100",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "2.5㎜",
"ToolOther": "95cN・m",
"WorkName": "周辺部品取付",
"WorkItems": [
"◆1. にGUIDE をSPACER BOLT で取付ける"
],
"WorkPoints": [
"GUIDE の内側にグリースを塗布後、取付",
"GUIDE は右側に当付けて取付"
],
"Tolks": [
"締付トルク 95cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"グリース塗布 米粒:3",
"◆作業者安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "95cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "2.5㎜",
"ToolOther": "95cN・m",
"WorkName": "スペーサー取付・動作確認",
"WorkItems": [
"3. COLLAR をBOLT で取付ける",
"◆1. WASHER にグリースを塗布する",
"2. WASHER をBOLT WASHER で取付ける"
],
"WorkPoints": [],
"Tolks": [
"締付トルク 95cN・m",
"締付トルク 95cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"◆作業者安全作業",
"・内面(側面)に グリースを塗布する",
"グリース塗布 米粒:各1"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "95cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "スペーサー取付・動作確認",
"WorkItems": [
"◆1. WASHER にグリースを塗布する",
"2. WASHER をBOLT WASHER で取付ける",
"3. COLLAR をBOLT で取付ける"
],
"WorkPoints": [],
"Tolks": [
"締付トルク 95cN・m",
"締付トルク 95cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"・内面(側面)に グリースを塗布する",
"グリース塗布 米粒:各1",
"グリース塗布 ゴマ粒:各1"
]
}
|
{
"QualityItem": "塗布量",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "米粒:各1ゴマ粒:各1",
"Method": "目視",
"RecordMethod": "-",
"Other": "グリースLCG100",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "2.5㎜",
"ToolOther": "95cN・m",
"WorkName": "ポスト取付",
"WorkItems": [
"1. にSPACER をBOLT で取付ける"
],
"WorkPoints": [],
"Tolks": [
"締付トルク 95cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": []
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "95cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "スケール",
"Size": "150㎜",
"ToolOther": "",
"WorkName": "銘板貼付",
"WorkItems": [
"1. にLABEL LABEL ④を貼付ける"
],
"WorkPoints": [
"指示箇所にラベルを貼付け、剥がれ無い事を確認する"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"1㎜",
"30㎜",
"32㎜",
"26㎜",
"2㎜",
"0.5㎜",
"5㎜",
"検査表 :.ラベル貼付確認"
]
}
|
{
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指定寸法各±0.5㎜",
"Method": "スケール",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "ノズルチェンジャー装着確認治具",
"Size": "",
"ToolOther": "FM-2902",
"WorkName": "機能検査",
"WorkItems": [
"2. シャッターの動作確認",
"2. シャッターの動作確認"
],
"WorkPoints": [
"・ストローグ全域で最大荷重を測定する (4.2N 以下)",
"・ストローグ全域で最大荷重を測定する (4.2N 以下)"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表 :シャッター動作確認",
"検査表 :シャッター動作確認",
"WDQB-F013-020"
]
}
|
{
"QualityItem": "脱着確認",
"ToolManageNo": "FM-2902",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "引っ掛かりが無い事",
"Method": "目視",
"RecordMethod": "WDQB-F013-020",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "プッシュプルゲージ",
"Size": "",
"ToolOther": "",
"WorkName": "機能検査",
"WorkItems": [
"2. シャッターの動作確認"
],
"WorkPoints": [
"・ストローグ全域で最大荷重を測定する (4.2N 以下)"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表 :シャッター動作確認",
"WDQB-F013-020"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolCycle": "1回/1年",
"ToolRecord": "校正成績書",
"StdVal": "4.2N以下",
"Method": "目視",
"RecordMethod": "WDQB-F013-020",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "HANDY-CHECKER",
"Size": "",
"ToolOther": "OMRONE39-VA",
"WorkName": "機能検査",
"WorkItems": [
"2. シャッターの動作確認"
],
"WorkPoints": [
"・ストローグ全域で最大荷重を測定する (4.2N 以下)"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表 :シャッター動作確認"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通りに点灯する事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "NPMノズルチェンジャー機能検査治具",
"Size": "",
"ToolOther": "FM-2169",
"WorkName": "機能検査",
"WorkItems": [
"2. シャッターの動作確認",
"4. ノズル挿抜確認"
],
"WorkPoints": [
"・ストローグ全域で最大荷重を測定する (4.2N 以下)",
"・引っかかりが無くスムーズな事・ノズルに遊びがある事・シャッターが閉じた状態でノズルが 抜け無い事",
"・スイッチ開側(上)で開ランプ (点灯)する事・スイッチ閉側(下)で閉ランプ (点灯)する事"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表 :シャッター動作確認",
"検査表 :ノズル挿抜確認",
"WDQB-F013-020"
]
}
|
{
"QualityItem": "挿抜確認",
"ToolManageNo": "FM-2169",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "スムーズである事",
"Method": "手感",
"RecordMethod": "WDQB-F013-020",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "3ノズル治具",
"Size": "",
"ToolOther": "",
"WorkName": "機能検査",
"WorkItems": [
"1. ノズルチェンジャー着脱確認",
"2. シャッターの動作確認",
"4. ノズル挿抜確認",
"3. チェンジャーの自重落下確認"
],
"WorkPoints": [
"・着脱の際、引っかかりが無い事",
"・ストローグ全域で最大荷重を測定する (4.2N 以下)",
"・引っかかりが無くスムーズな事・ノズルに遊びがある事・シャッターが閉じた状態でノズルが 抜け無い事",
"・スイッチ開側(上)で開ランプ (点灯)する事・スイッチ閉側(下)で閉ランプ (点灯)する事",
"※9ステーションにノズル冶具をセットして確認する事",
"・隙間無い事",
"・チェッカーが点灯 する事"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"・自重落下する事",
"・レバーを押す",
"・シャッター「開」でノズルセット",
"・シャッター「閉」",
"・シャッター「開閉」スイッチ",
"FM-2169",
"FM-2902",
"検査表 :ノズルチェンジャー着脱確認",
"検査表 :シャッター動作確認",
"検査表 :ノズル挿抜確認",
"WDQB-F013-020"
]
}
|
{
"QualityItem": "挿抜確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "引っ掛かりが無い事",
"Method": "手感",
"RecordMethod": "WDQB-F013-020",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "シート確認",
"WorkItems": [
"1. シート(傷防止)が剥がれてい無い事を確認する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"シート",
"検査表 :シート(傷防止)貼付確認",
"WDQB-F013-020"
]
}
|
{
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り貼付け出来ている事",
"Method": "目視",
"RecordMethod": "WDQB-F013-020",
"Other": "-",
"ProcessNames": [
"作業者安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPU_BOX組立",
"WorkItems": [
"■1. BOX の型式を確認し、シリアルNoを検査表に記入する",
"2. BOX にLABEL LABEL LABEL を貼付ける"
],
"WorkPoints": [
"筐体上面にラベルを貼付 (貼付方向に注意)",
"EXTENDED UNITがある場合のみLABEL を貼付ける"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表BOX :筐体の型式確認",
"検査表BOX :レターコード貼付け",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPU_BOX組立",
"WorkItems": [
"■1. BOX の型式を確認し、シリアルNoを検査表に記入する",
"2. BOX にLABEL LABEL LABEL を貼付ける"
],
"WorkPoints": [
"筐体上面にラベルを貼付 (貼付方向に注意)",
"EXTENDED UNITがある場合のみLABEL を貼付ける"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表BOX :筐体の型式確認",
"検査表BOX :レターコード貼付け",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "スケール",
"Size": "150㎜",
"ToolOther": "",
"WorkName": "CPU_BOX組立",
"WorkItems": [
"■1. BOX の型式を確認し、シリアルNoを検査表に記入する",
"2. BOX にLABEL LABEL LABEL を貼付ける"
],
"WorkPoints": [
"筐体上面にラベルを貼付 (貼付方向に注意)",
"EXTENDED UNITがある場合のみLABEL を貼付ける"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表BOX :筐体の型式確認",
"検査表BOX :レターコード貼付け",
"■安全作業"
]
}
|
{
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指示寸法各±1㎜",
"Method": "スケール",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPUボード確認(K306)",
"WorkItems": [
"2. 付属のWindowsライセンスシールのライセンス番号を検査表に記入する",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"シリアルNo",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :ライセンスの確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPUボード確認(K306)",
"WorkItems": [
"2. 付属のWindowsライセンスシールのライセンス番号を検査表に記入する",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"シリアルNo",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :ライセンスの確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPUボード確認(K306)",
"WorkItems": [
"2. 付属のWindowsライセンスシールのライセンス番号を検査表に記入する",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"シリアルNo",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :ライセンスの確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "ライセンス記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "ライセンス番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "CPUボード設定、取付(K306)",
"WorkItems": [
"★1. に を取付ける"
],
"WorkPoints": [
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表 :接続確認",
"★静電対策作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "CPUボード設定、取付(K306)",
"WorkItems": [
"★1. に を取付ける",
"★2. CPUボードのカードスロットにREMOVABLE-MEMORY を挿入する",
"3. 2完成品にCONNECTOR-COVER を取付ける"
],
"WorkPoints": [
"K306",
"挿入方向に注意",
"青マーキングし検査書に記入する事",
"カバーを取外し、カードを挿入後、カバーを戻す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"カバー",
"ネジ",
"検査表 :付属品取付",
"検査表 :接続確認",
"検査表 :付属品取付",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "付属品取付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K303、K305)",
"WorkItems": [
"★2. にPOWER-SUPPLY を取付ける",
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [
"K303",
"K305",
"型式",
"シリアルNo.",
"取付け時CPUボードに擦らないよう注意",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K303、K305)",
"WorkItems": [
"★2. にPOWER-SUPPLY を取付ける",
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [
"K303",
"K305",
"型式",
"シリアルNo.",
"取付け時CPUボードに擦らないよう注意",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K303、K305)",
"WorkItems": [
"★2. にPOWER-SUPPLY を取付ける",
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する"
],
"WorkPoints": [
"K303",
"K305",
"型式",
"シリアルNo.",
"取付け時CPUボードに擦らないよう注意",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K302、K304)",
"WorkItems": [
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する",
"★2. にPOWER-SUPPLY を取付ける"
],
"WorkPoints": [
"K302",
"K304",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K302、K304)",
"WorkItems": [
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する",
"★2. にPOWER-SUPPLY を取付ける"
],
"WorkPoints": [
"K302",
"K304",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K302、K304)",
"WorkItems": [
"■★1. POWER-SUPPLY の型式を確認し、シリアルNoを検査表に記入する",
"★2. にPOWER-SUPPLY を取付ける"
],
"WorkPoints": [
"K302",
"K304",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表POWER-SUPPLY :型式・検査書チェック",
"検査表POWER-SUPPLY :接続確認",
"削除",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける",
"★3. 2完成品にPCB-COM 付属品コネクタを挿し込む"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"分岐ケーブル",
"検査表PCB-COM :分岐ケーブル接続確認",
"設定:0",
"検査表PCB-COM :付属品取付",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける",
"★3. 2完成品にPCB-COM 付属品コネクタを挿し込む"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"分岐ケーブル",
"検査表PCB-COM :分岐ケーブル接続確認",
"設定:0",
"検査表PCB-COM :付属品取付",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける",
"★3. 2完成品にPCB-COM 付属品コネクタを挿し込む"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"分岐ケーブル",
"検査表PCB-COM :分岐ケーブル接続確認",
"設定:0",
"検査表PCB-COM :付属品取付",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける",
"★3. 2完成品にPCB-COM 付属品コネクタを挿し込む"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"分岐ケーブル",
"検査表PCB-COM :分岐ケーブル接続確認",
"設定:0",
"検査表PCB-COM :付属品取付",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "接続確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り接続出来ている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"分岐ケーブル",
"検査表PCB-COM :付属品取付",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K307)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"5. 4完成品にCONNECTOR-COVER を取付ける",
"★4. に3.完成品を取付ける",
"★3. 2完成品にPCB-COM 付属品コネクタを挿し込む"
],
"WorkPoints": [
"K307付属品",
"K307",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"PCB-COM 付属品",
"検査表PCB-COM :接続確認",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"分岐ケーブル",
"検査表PCB-COM :分岐ケーブル接続確認",
"設定:0",
"検査表PCB-COM :付属品取付",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "付属品取付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K308)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける",
"★2. PCB-COM のスイッチ設定確認"
],
"WorkPoints": [
"青マーキングし検査書に記入する事",
"K308"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :型式・検査書チェック",
"設定:0",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K308)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける",
"★2. PCB-COM のスイッチ設定確認"
],
"WorkPoints": [
"青マーキングし検査書に記入する事",
"K308"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :型式・検査書チェック",
"設定:0",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K308)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける",
"★2. PCB-COM のスイッチ設定確認"
],
"WorkPoints": [
"青マーキングし検査書に記入する事",
"K308"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :型式・検査書チェック",
"設定:0",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K308)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける",
"★2. PCB-COM のスイッチ設定確認"
],
"WorkPoints": [
"青マーキングし検査書に記入する事",
"K308"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"■安全作業",
"★静電対策作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K309)",
"WorkItems": [
"★2. PCB-COM のスイッチ設定確認",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K309",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K309)",
"WorkItems": [
"★2. PCB-COM のスイッチ設定確認",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K309",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K309)",
"WorkItems": [
"★2. PCB-COM のスイッチ設定確認",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K309",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K309)",
"WorkItems": [
"★2. PCB-COM のスイッチ設定確認",
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K309",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K310-K314)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する(K310-K314)",
"★2. PCB-COM のスイッチ、ジャンパー設定確認(K310-K314)",
"★3. にPCB-COM を取付ける(K310-K314)"
],
"WorkPoints": [
"K310",
"K311",
"K313",
"K314",
"K312",
"ジャンパーが無いことを確認(K310-K314)",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"-K310用",
"-K311用",
"-K312用",
"-K313用",
"-K314用",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K310-K314)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する(K310-K314)",
"★2. PCB-COM のスイッチ、ジャンパー設定確認(K310-K314)",
"★3. にPCB-COM を取付ける(K310-K314)"
],
"WorkPoints": [
"K310",
"K311",
"K313",
"K314",
"K312",
"ジャンパーが無いことを確認(K310-K314)",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"-K310用",
"-K311用",
"-K312用",
"-K313用",
"-K314用",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K310-K314)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する(K310-K314)",
"★2. PCB-COM のスイッチ、ジャンパー設定確認(K310-K314)",
"★3. にPCB-COM を取付ける(K310-K314)"
],
"WorkPoints": [
"K310",
"K311",
"K313",
"K314",
"K312",
"ジャンパーが無いことを確認(K310-K314)",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"-K310用",
"-K311用",
"-K312用",
"-K313用",
"-K314用",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K310-K314)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する(K310-K314)",
"★2. PCB-COM のスイッチ、ジャンパー設定確認(K310-K314)",
"★3. にPCB-COM を取付ける(K310-K314)"
],
"WorkPoints": [
"K310",
"K311",
"K313",
"K314",
"K312",
"ジャンパーが無いことを確認(K310-K314)",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K315)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K315",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K315)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K315",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K315)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K315",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K315)",
"WorkItems": [
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K315",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K316)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K316",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K316)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K316",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K316)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K316",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K316)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K316",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K317)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K317",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K317)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K317",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K317)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K317",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:0",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-168"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-168",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K317)",
"WorkItems": [
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K317",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "固定用ブラケット取付(CPUUNIT)",
"WorkItems": [
"1. にBRACKET BRACKET を取付ける"
],
"WorkPoints": [
"面合わせ",
"BOX組付けネジ",
" BOX組付けネジを緩めて、BRACKET BRACKET を挟み込み再度ネジで締付ける"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": []
}
|
{
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"削除"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "EXTENDEDUNIT設定、ボード取付",
"WorkItems": [],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "EXTENDEDUNIT設定、ボード取付",
"WorkItems": [],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "スケール",
"Size": "300㎜",
"ToolOther": "",
"WorkName": "EXTENDEDUNIT設定、ボード取付",
"WorkItems": [],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": []
}
|
{
"QualityItem": "貼付確認",
"ToolManageNo": "-",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "指示寸法各±1㎜",
"Method": "スケール",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "EXTENDEDUNIT設定、ボード取付",
"WorkItems": [],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": []
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K340)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ、ジャンパー設定確認",
"★3. にPCB-COM PANEL 、 付属品を取付ける"
],
"WorkPoints": [
"K340",
"ジャンパーが無いことを確認",
"CPU UNIT側で外したパネルを使用",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:7",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K340)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ、ジャンパー設定確認",
"★3. にPCB-COM PANEL 、 付属品を取付ける"
],
"WorkPoints": [
"K340",
"ジャンパーが無いことを確認",
"CPU UNIT側で外したパネルを使用",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:7",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K340)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ、ジャンパー設定確認",
"★3. にPCB-COM PANEL 、 付属品を取付ける"
],
"WorkPoints": [
"K340",
"ジャンパーが無いことを確認",
"CPU UNIT側で外したパネルを使用",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:7",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K340)",
"WorkItems": [
"★3. にPCB-COM PANEL 、 付属品を取付ける"
],
"WorkPoints": [
"K340",
"ジャンパーが無いことを確認",
"CPU UNIT側で外したパネルを使用",
"青マーキングし検査書に記入する事",
"取付け時、オレンジ色のゴムは外す"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K341)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K341",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K341)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K341",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K341)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K341",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K341)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K341",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"削除",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K342)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K342",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "型式確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "型式が一致する事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K342)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K342",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "製造番号記録",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "製造番号転記",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "ボード設定、取付(K342)",
"WorkItems": [
"■★1. PCB-COM の型式を確認し、シリアルNoを検査表に記入する",
"★2. PCB-COM のスイッチ設定確認",
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K342",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定:1",
"検査表PCB-COM :型式・検査書チェック",
"検査表PCB-COM :基板ジャンパー設定確認",
"検査表PCB-COM :接続確認",
"GWCZ-E013-302"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り設定されている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-302",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "トルクドライバー",
"Size": "No.1",
"ToolOther": "34cN・m",
"WorkName": "ボード設定、取付(K342)",
"WorkItems": [
"★3. にPCB-COM を取付ける"
],
"WorkPoints": [
"K342",
"青マーキングし検査書に記入する事"
],
"Tolks": [
"締付トルク 34cN・m"
],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表PCB-COM :接続確認",
"★静電対策作業",
"■安全作業"
]
}
|
{
"QualityItem": "締付トルク",
"ToolManageNo": "-",
"ToolCycle": "日常点検(1回/日)",
"ToolRecord": "トルクチェック台帳",
"StdVal": "34cN・m±10%",
"Method": "トルクドライバー",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "固定用ブラケット取付(EXTENDEDUNIT)",
"WorkItems": [
"1. にBRACKET BRACKET を取付ける"
],
"WorkPoints": [
"面合わせ",
"BOX組付けネジ",
" BOX組付けネジを緩めて、BRACKET BRACKET を挟み込み再度ネジで締付ける"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"削除"
]
}
|
{
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "-",
"Size": "",
"ToolOther": "",
"WorkName": "増設ケーブルラベル結束",
"WorkItems": [],
"WorkPoints": [],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"GWCZ-E013-296"
]
}
|
{
"QualityItem": "取付確認",
"ToolManageNo": "-",
"ToolCycle": "-",
"ToolRecord": "-",
"StdVal": "指示通り取付出来ている事",
"Method": "目視",
"RecordMethod": "GWCZ-E013-296",
"Other": "-",
"ProcessNames": [
"安全工程"
]
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_測定準備",
"WorkItems": [
"1. XYユニットチェッカーケーブルを本体エンコーダと接続する",
"2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる",
"3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する"
],
"WorkPoints": [
"フロント側",
"チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する",
"接続1",
"接続2"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"Y軸 ①",
"Y軸 ②",
"COM 2",
"X5K506",
"接続",
"接続",
"接続",
"接続",
"ケーブルカバー㉗",
"X5K502",
"COM 1",
"ケーブルカバー㉗"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りの設定になっている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYチェッカーコネクターカバー",
"Size": "",
"ToolOther": "FM-3979",
"WorkName": "フロント側_Y軸①_測定準備",
"WorkItems": [
"1. XYユニットチェッカーケーブルを本体エンコーダと接続する",
"2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『Y AxisC』をクリックし、調整用ソフトを立ち上げる",
"3. 機種選択、Y軸①設定のシリアルポートとY軸②設定のシリアルポートを確認する"
],
"WorkPoints": [
"フロント側",
"チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを接続する",
"接続1",
"接続2"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"Y軸 ①",
"Y軸 ②",
"COM 2",
"X5K506",
"接続",
"接続",
"接続",
"接続",
"ケーブルカバー㉗",
"X5K502",
"COM 1",
"ケーブルカバー㉗"
]
}
|
{
"QualityItem": "作業確認",
"ToolManageNo": "FM-3979",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_信号Monitor1",
"WorkItems": [
"1. チェッカー電源㉖をONにする",
"2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる",
"4. 『信号Monitor』をクリックする",
"3. Xビームをフロント側メカストッパーまで移動する"
],
"WorkPoints": [
"通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する",
"画面表示で自動ON"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"信号Monitor"
]
}
|
{
"QualityItem": "表示確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りに表示されている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_信号Monitor2",
"WorkItems": [
"3. 『終了』を押す",
"2. ScaleA、B、Cのmax値の中で最も高い数値の位置へXビームを移動する",
"1. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)"
],
"WorkPoints": [
"フロント側",
"Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"メーター",
"メーター、及びメーター値を見ながらmax値の位置まで移動",
"max 値",
"メーター値"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_信号調整START",
"WorkItems": [
"1. 『信号調整Start』をクリックする",
"2. 『開始』をクリックする",
"3. Loopカウンターが動き出したら、Xビームをリア側に動かす",
"4. 【信号を確認します】が表示されたら、Xビームをフロント側に戻す"
],
"WorkPoints": [
"フロント側",
"フロント側",
"Xビームは50mm/sec以下で60mm以上移動させる事"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"信号調整Start"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_Gain設定確認",
"WorkItems": [
"1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する",
"2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る",
"3. Xビームをフロント側メカストッパーまで移動する"
],
"WorkPoints": [
"NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す",
"OKを確認"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"設定確認",
"■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9",
"検査表①:No10 XY軸リニアスケール信号調整",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "XY軸リニアスケール信号調整",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①_信号Monitor3",
"WorkItems": [
"3. 『終了』を押す",
"4. Xビームをフロント側メカストッパーまで移動する",
"1. 『信号Monitor』をクリックする",
"2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)"
],
"WorkPoints": [
"画面表示で自動ON",
"フロント側",
"OKを確認",
"■信号強度規格_min:40以上/max:80以下",
"NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表①:No,10 XY軸リニアスケール信号調整",
"信号Monitor",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "XY軸リニアスケール信号調整",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "OK表示である事max値:各80以下min値:各40以上",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸②_信号Monitor1",
"WorkItems": [
"4. 『終了』を押す",
"1. 『信号Monitor』をクリックする",
"2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)",
"3. ScaleA、B、Cのmax値の中で最も高い数値の位置へX軸を移動する"
],
"WorkPoints": [
"画面表示で自動ON",
"フロント側",
"Xビームを移動するとメーターが変化する最も高い数値の位置が信号調整Startの開始位置になるので絶対に移動し無い事"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"信号Monitor",
"メーター、及びメーター値を見ながらmax値の位置まで移動",
"メーター",
"max 値",
"メーター値"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸②_信号調整START",
"WorkItems": [
"1. 『信号調整Start』をクリックする",
"2. 『開始』をクリックする",
"3. Loopカウンターが動き出したら、Xビームをリア側に動かす",
"4. 【信号を確認します】が表示されたら、Xビームをフロント側に戻す"
],
"WorkPoints": [
"フロント側",
"Xビームは50mm/sec以下で60mm以上移動させる事",
"フロント側"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"信号Monitor",
"信号調整Start"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸②_Gain設定確認",
"WorkItems": [
"1. 『Gain設定確認』をクリックしScale A,B,Cの判定がOKか確認する",
"2. Scale A,B,Cの判定がOKなら『終了』をクリックし、メニューに戻る",
"3. Xビームをフロント側メカストッパーまで移動する"
],
"WorkPoints": [
"NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し 『信号調整Start』からやり直す",
"OKを確認"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"■Gain設定規格・Scale A:5~8・Scale B:4~9・Scale C:4~9",
"検査表①:No10 XY軸リニアスケール信号調整",
"Gain設定確認",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "XY軸リニアスケール信号調整",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "Gain設定ScaleA:5~8ScaleB/C:4~9",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸②_信号Monitor2",
"WorkItems": [
"3. 『終了』を押す",
"1. 『信号Monitor』をクリックする",
"4. Xビームをフロント側メカストッパーまで移動する",
"2. Xビームをフルストローク往復させ測定する(フロント側メカストッパー~リア側メカストッパーまでを往復)"
],
"WorkPoints": [
"画面表示で自動ON",
"フロント側",
"OKを確認",
"■信号強度規格_min:40以上/max:80以下",
"NGの場合は信号Monitorのmax値位置にてリニアスケールと読み取りヘッドの隙間を再調整し『信号調整Start』からやり直す"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"検査表①:No,10 XY軸リニアスケール信号調整",
"信号Monitor",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "XY軸リニアスケール信号調整",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "OK表示である事max値:各80以下min値:各40以上",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①②_原点プリセット",
"WorkItems": [
"2. 『原点プリセット』をクリックする",
"3. 『F側SET』をクリックする",
"4. 『終了』をクリックする",
"1. Xビームをフロント側メカストッパーに当付ける"
],
"WorkPoints": [
"D_Pos1:-18.5㎜",
"D_Pos4:179.5㎜",
"D_Pos2:18.5㎜",
"D_Pos3:-179.5㎜",
"D_Pos値は固定値_入力不要",
"SET_Pos値は『0.00』_入力不要",
"18.5000が表示",
"-18.5000が表示",
"右のOKランプ点灯",
"右のOKランプ点灯",
"完了ランプ点灯"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"原点プリセット",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "原点プリセット値設定確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "Y軸①プリセット値:-18.5㎜Y軸②プリセット値:18.5㎜",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_偏差測定1",
"WorkItems": [
"1. Xビームをフロント側メカストッパーに当付ける",
"2. 『偏差測定』をクリックする",
"4. 3位置にて『データ取込』をクリックする(PCの『Enterキー』でも可)",
"3. Xビームを【 0(ゼロ)】付近に移動する"
],
"WorkPoints": [
"移動後の誤差は±10㎜以内にする事",
"取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"※注意",
"-方向で取込むことGOOD",
"戻り方向で取込みはNG",
"Xビーム",
"Xビーム",
"偏差測定"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_偏差測定2",
"WorkItems": [
"2. 『終了』をクリックする",
"1. Xビームを100㎜毎移動させデータを取込む",
"3. Xビームをフロント側メカストッパーに当付ける"
],
"WorkPoints": [
"100㎜づつ、計10回取込",
"100㎜~1000㎜まで取込む",
"移動後の誤差は±10㎜以内にする事。【 0(ゼロ) 】付近取込時同様、戻り方向での取込みは禁止",
"取込み位置を行き過ぎてしまった場合は、再度戻り-方向で必ず行うこと"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"0mm → データ取込 済 100mm → データ取込 ・ ・ ・ ・ ・ 1000mm → データ取込",
"※注意",
"-方向で取込むことGOOD",
"戻り方向で取込みはNG",
"Xビーム",
"Xビーム"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_偏差設定",
"WorkItems": [
"1. 『偏差設定』をクリックする",
"2. 『F側SET』をクリックする",
"3. 『終了』をクリックする"
],
"WorkPoints": [
"偏差調整値が表示されている",
"右のOKランプ点灯",
"右のOKランプ点灯",
"完了ランプ点灯",
"Y-2:偏差調整後の数値が表示",
"Y-1:-18.5000が表示"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"偏差設定"
]
}
|
{
"QualityItem": "原点プリセット値登録確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りに表示されている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_ストローク確認",
"WorkItems": [
"2. 『ストローク確認』をクリックする",
"3. フロントXビームをY軸フロントストッパーに押し当て測定する",
"4. フロントXビームをY軸リアストッパーに押し当て測定する",
"1. Xビームをフロント側メカストッパーに当付ける"
],
"WorkPoints": [
"■規格値Y軸① -18.7mm~-18.3mmY軸② 18.3mm~18.7mm",
"■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"奥側ストローク位置",
"手前側ストローク位置",
"手前側ストローク位置データを記入",
"ストローク確認",
"検査表①:No,12 Y軸ストローク確認",
"検査表①:No,12 Y軸ストローク確認",
"奥側ストローク位置データを記入",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "測定値記録",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "規格値Y軸①-18.7~-18.3㎜Y軸②18.3~18.7㎜",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_ストローク確認",
"WorkItems": [
"2. 『ストローク確認』をクリックする",
"3. フロントXビームをY軸フロントストッパーに押し当て測定する",
"4. フロントXビームをY軸リアストッパーに押し当て測定する",
"1. Xビームをフロント側メカストッパーに当付ける"
],
"WorkPoints": [
"■規格値Y軸① -18.7mm~-18.3mmY軸② 18.3mm~18.7mm",
"■規格値Y軸① 1117mm~1298.5mmY軸② -1298.5mm~-1117mm"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"奥側ストローク位置",
"手前側ストローク位置",
"手前側ストローク位置データを記入",
"ストローク確認",
"検査表①:No,12 Y軸ストローク確認",
"検査表①:No,12 Y軸ストローク確認",
"奥側ストローク位置データを記入",
"WEPJ-G002-C02"
]
}
|
{
"QualityItem": "測定値記録",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "規格値Y軸①1117~1298.5㎜Y軸②-1298.5~-1117㎜",
"Method": "目視",
"RecordMethod": "WEPJ-G002-C02",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸①②_エラー履歴クリア",
"WorkItems": [
"1. 『エラー履歴クリア』クリックする",
"2. 『クリア』をクリックする",
"3. 完了ランプ点灯を確認し『終了』をクリックする",
"4. 『終了』をクリックし『×』をクリックする"
],
"WorkPoints": [
"完了ランプ点灯"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"エラー履歴クリア"
]
}
|
{
"QualityItem": "表示確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りに表示されている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_Y軸_XYチェッカー切り離し",
"WorkItems": [
"1. チェッカー電源㉖をOFFにする",
"2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す"
],
"WorkPoints": [
"フロント側",
"チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す",
"切り離し1",
"切り離し2"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"Y軸 ①",
"Y軸 ②",
"OFF",
"ON",
"COM 2",
"X5K506",
"外す",
"外す",
"ケーブルカバー㉗",
"X5K502",
"COM 1",
"ケーブルカバー㉗"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りの設定になっている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYチェッカーコネクターカバー",
"Size": "",
"ToolOther": "FM-3979",
"WorkName": "フロント側_Y軸_XYチェッカー切り離し",
"WorkItems": [
"1. チェッカー電源㉖をOFFにする",
"2. 本体エンコーダケーブルとXYユニットチェッカーケーブルを切り離す"
],
"WorkPoints": [
"フロント側",
"チェッカー電源がOFFになっていることを確認し、本体エンコーダケーブルを外す",
"切り離し1",
"切り離し2"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"Y軸 ①",
"Y軸 ②",
"OFF",
"ON",
"COM 2",
"X5K506",
"外す",
"外す",
"ケーブルカバー㉗",
"X5K502",
"COM 1",
"ケーブルカバー㉗"
]
}
|
{
"QualityItem": "取外確認",
"ToolManageNo": "FM-3979",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_X軸_測定準備",
"WorkItems": [
"1. XYユニットチェッカーケーブルを本体エンコーダと繋ぐ",
"3. 機種選択、シリアルポートを確認する",
"2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる"
],
"WorkPoints": [
"フロント側",
"チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを繋ぐ",
"接続"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"COM 1",
"接続",
"ケーブルカバー㉗",
"X5K501",
"X軸"
]
}
|
{
"QualityItem": "設定確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通りの設定になっている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYチェッカーコネクターカバー",
"Size": "",
"ToolOther": "FM-3979",
"WorkName": "フロント側_X軸_測定準備",
"WorkItems": [
"1. XYユニットチェッカーケーブルを本体エンコーダと繋ぐ",
"3. 機種選択、シリアルポートを確認する",
"2. PCを立ち上げ、 NPM XYユニットチェッカーアイコン『X AxisC』をクリックし、調整用ソフトを立ち上げる"
],
"WorkPoints": [
"フロント側",
"チェッカー電源㉖がOFFになっていることを確認し、チェッカーケーブルカバー、付属ケーブル㉗、本体エンコーダケーブルを繋ぐ",
"接続"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"COM 1",
"接続",
"ケーブルカバー㉗",
"X5K501",
"X軸"
]
}
|
{
"QualityItem": "作業確認",
"ToolManageNo": "FM-3979",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|
0
| null |
|
{
"ToolName": "XYユニットチェッカー",
"Size": "",
"ToolOther": "FM-2224",
"WorkName": "フロント側_X軸_信号Monitor1",
"WorkItems": [
"1. チェッカー電源㉖をONにする",
"4. 『信号Monitor』をクリックする",
"3. X軸を左側メカストッパーまで移動する",
"2. 『起動』をクリックすると通信確認OKと表示され画面が切り替わる"
],
"WorkPoints": [
"通信エラ-の場合はケーブル繋ぎ、チェッカー電源(ON)を確認する",
"画面表示で自動ON"
],
"Tolks": [],
"InspectionNo": "",
"InspectionItems": [],
"WorkTypes": [],
"Words": [
"OFF",
"ON",
"信号Monitor"
]
}
|
{
"QualityItem": "動作確認",
"ToolManageNo": "FM-2224",
"ToolCycle": "校正対象外",
"ToolRecord": "-",
"StdVal": "作業指示通り作業出来ている事",
"Method": "目視",
"RecordMethod": "-",
"Other": "-",
"ProcessNames": []
}
|
information_extraction
|